OPEN STEEL FLOOR GRATING
|
|
- Duane Derrick Turner
- 7 years ago
- Views:
Transcription
1 OPEN STEEL FLOOR GRATING Conforms to Specification RR-G-661 Smooth-surface grating Serrated-surface safety grating Grating available in Carbon Steel, Aluminum, Stainless, & Fiberglass STANDARD MESH S CLOSE MESH S 19W4 19W2 15W4 15W2 Bearing Bars Center to Center Cross Bars 1-3/16 Center to Center 15/16 3 /4 x 1 / /4 x 3 / x 1 / x 3 / /4 x 1 / /4 x 3 / /2 x 1 / /2 x 3 / /4 x 3 / x 3 / /4 x 3 / /2 x 3 / Panel Width in Inches Lbs. Per Sq. Ft. Bearing Type Type Type Type Bars 19W4 19W2 15W4 15W2 Stock Sizes Panel Length in Inches 24, , 288 Other bearing bar sizes and spacings are available. All grating can be cut to your specifications. When ordering GRATING, specify: Type of GRATING Size of BEARING BARS (Depth & Width) Span (direction of bearing bars) Dimensions of area Unpainted, Painted or Galvanized, Smooth or Serrated Special shapes can be furnished with, or without, edge banding. When ordering STAIR TREADS, also specify: Width & Length Type of Nosing (Checker Plate or Cast Iron Abrasive) Punching in side plates or standardized dimensions may be altered to suit special conditions.
2 EXPANDED METAL Expanded Metal may be used for many industrial purposes such as open partitions, window guards, machine guards, and other manufacturing and maintenance uses. It is more rigid than an equal weight of solid steel plate or wire mesh. In fabricating, it may be cut to any desired shape without loss of its original strength. LWD LWO BOND SWD (Short Way of Design) nominal dimension LWD (Long Way of Design) nominal dimension SWO (Short Way of Opening) LWO (Long Way of Opening) SWO SWD LWD Strand Thickness (Ga.) Strand Width SWD EXPANDED STEEL STANDARD Carbon (MIL-M Type I Class 1, ASTM F 1267 Type I Class 1) and Stainless Steels** (MIL-M Type I Class 3) Length Est. Lbs. Approx. Size of Style Approx. Width in in Per Opening in Inches Designation* Thickness Inches Inches Sq. Ft. SWO LWO 1 /4 x #20 (.036) 36, x /4 x #18 (.048) x /2 x #18 (.048) x /2 x #16 (.060) x x /2 x #13 (.092) x /4 x #16 (.060) 48, x /4 x #13 (.092) 48, x x /4 x #10 (.092) x /4 x #9 (.134) 48, x x /2 x #13 (.092) 48, x x /2 x #9 (.134) x , x x #9 (.134) x ** The first number represents the nominal width of diamond in inches measured from center to center of bonds; the second number usually represents the approximate gage of sheet or plate before expanding. Sheets of special size can be furnished. ** Stainless Steel weights are slightly higher EXPANDED STEEL GRATING STANDARD Length Est. Lbs. Width in in Per Approx. Size of Style Designation Inches Inches Sq. Ft. Opening in Inches 3.0 Lb. Grating /16 x 3 7 / Lb. Grating /8 x 4 7 /8 4.0 Lb. Grating /16 x 3 7 / Lb. Grating 48, x 2 7 / Lb. Grating /16 x 3 3 /8
3 EXPANDED STEEL FLATTENED Carbon (MIL-M Type II Class 1, ASTM F 1267 Type II Class 1) and Stainless Steel Type 304** (MIL-M Type II Class 3) Approx. Thk. Length Est. Lbs. Approx. Size of Style After Width in in Per Opening in Inches Designation* Flattening Inches Inches Sq. Ft. SWO LWO 1 /4 x #20 (.030) x /4 x #18 (.040) 36, x /2 x #20 (.029) x /2 x #18 (.039) 36, 48** x x /2 x #16 (.050) 36, 48** x /2 x #13 (.070) 48** x x /4 x #18 (.040) x /4 x #16 (.048) 36**, 48** x x /4 x #14 (.061) x /4 x #13 (.070) 48** x /4 x #9 (.120) 36, 48** x x /2 x #16 (.048) x /2 x #13 (.070) 48** x /2 x #9 (.110) 36, 48** x x ** The first number represents the nominal width of diamond in inches measured from center to center of bonds; the second number usually represents the approximate original gage before expanding. Sheets of special size can be furnished. ** Also available in Stainless Steel. Weights will be slightly higher. Stainless Steel only. Weights will be slightly higher. EXPANDED ALUMINUM STANDARD 3003-H14 Length Est. Lbs. Approx. Size of Width in in Per Opening in Inches Style Designation Inches Inches Sq. Ft. SWO LWO 1 / , x / x / x /4.081 Heavy x / x EXPANDED ALUMINUM FLATTENED 3003-H14 Length Est. Lbs. Approx. Size of Width in in Per Opening in Inches Style Designation Inches Inches Sq. Ft. SWO LWO 1 / x / x / x /4.081 Heavy x / x 1.75
4 MORTON SAFETY PRODUCTS Designed to meet Federal Spec. RR-G-1602C DECK SPAN and GRIP-TRAC PLANKS DECK SPAN 14 Ga. x 4 3 /4 x 1 1 / Ga. x 7 x 1 1 / Ga. x 9 1 /2 x 1 1 / Ga. x 11 3 /4 x 1 1 / Ga. x 18 3 /4 x 1 1 / Ga. x 4 3 /4 x Ga. x 7 x Ga. x 9 1 /2 x Ga. x 11 3 /4 x Ga. x 18 3 /4 x Ga. x 4 3 /4 x 1 1 / Ga. x 7 x 1 1 / Ga. x 9 1 /2 x 1 1 / Ga. x 11 3 /4 x 1 1 / Ga. x 18 3 /4 x 1 1 / Ga. x 4 3 /4 x Ga. x 7 x Ga. x 9 1 /2 x Ga. x 11 3 /4 x Ga. x 18 3 /4 x Ga. x 24 x GRIP-TRAC Aluminum 5052-H x 4 3 /4 x x 7 x x 9 1 /2 x x 11 3 /4 x x 4 3 /4 x x 7 x x 9 1 /2 x x 11 3 /4 x x 18 3 /4 x *Also available as Hot Rolled Pickled & Oiled Steel, and as 16 Ga. T304 & T316L Stainless Steel 9 1 /2 wide & 11 3 /4 wide x 2 deep GRIP-TRAC WALKWAY Toeboard Gage Width Height # / # / *Also available as Hot Rolled Pickled & Oiled Steel
5 MORTON SAFETY PRODUCTS Designed to meet Federal Spec. RR-G-1602C OPEN-GRIP PLANKS 13 Ga. x 5 x 1 1 / Ga. x 7 x 1 1 / Ga. x 10 x 1 1 / Ga. x 12 x 1 1 / Ga. x 18 x 1 1 / Ga. x 5 x Ga. x 7 x Ga. x 10 x Ga. x 12 x Ga. x 18 x Ga. x 5 x 1 1 / Ga. x 7 x 1 1 / Ga. x 10 x 1 1 / Ga. x 12 x 1 1 / Ga. x 18 x 1 1 / Ga. x 5 x Ga. x 7 x Ga. x 10 x Ga. x 12 x Ga. x 18 x Aluminum 5052-H x 5 x x 7 x x 10 x x 12 x x 18 x *Also available as Hot Rolled Pickled and Oiled Steel OPEN-GRIP WALKWAY Toeboard Gage Width Height # # # # # *Also available as Hot Rolled Pickled & Oiled Steel
6 MORTON SAFETY PRODUCTS Designed to meet Federal Spec. RR-G-1602C TREAD-GRIP SHEETS Hot Rolled Pickled and Oiled* A permanent, non-skid surface for positive gripping action on steps and walkways. Made of mild steel. Lbs. Est. Lbs. Size in Inches Sq. Ft. Per Sht. 16 Ga. x 36 x Ga. x 36 x Ga. x 36 x *Also available as Pre-Galvanized Steel,.125 thick Aluminum 5052-H32, and 16 Ga. T304 2B Stainless Steel TREAD-GRIP LADDER RUNGS Hot Rolled Pickled and Oiled* Est. Lbs. Size in Inches Type Per Rung 13 Ga. x 1 5 /8 x 48 3 / Row Ga. x 2 1 /4 x 48 3 / Row *Also available as Pre-Galvanized Steel,.125 thick Aluminum 5052-H32, and 16 Ga. T304 2B Stainless Steel
There is no upside to. down time
EXPANDED and PERFORATED Data and Specifications 30 Similar to Type 302 with excellent mechanical properties, resistance to many corrosive agents. Useful where sanitation and cleanliness are important.
More informationEXPANDED METAL & GRATING
EXPANDED METAL & GRATING TERMINOLOGY...18-2 thru 18-3 ORDERING PROCEDURE... 18-3 EXPANDED METAL SHEETS Standard Carbon Sheets... 18-4 Flattened Carbon Sheets... 18-5 Standard Type 304 Stainless... 18-6
More informationSTOCK LIST & BUYER S GUIDE
STOCK LIST & BUYER S GUIDE common Decimal equivalents 1/64 =.0156 1/32 =.0312 1/16 =.0625 3/32 =.0937 1/8 =.125 3/16 =.1875 7/32 =.2187 1/4 =.250 9/32 =.2812 5/16 =.3125 3/8 =.375 7/16 =.4375 1/2 =.500
More informationTARIFF CODE and updates standard
TARIFF CODE and updates standard No HS CODE AHTN CODE PRODUCT DESCRIPTION PRODUCT TYPE STANDARDS IDENTIFIED 7207 Semi finished products of iron or non alloy steel Containing by weight less than 0.25% of
More informationSafety Grating GSSG-13R GRIP STRUT. safety grating
Safety Grating GSSG-13R safety grating Table of Contents & Advantages Advantages.................................................... 2 Proof Of Performance...................................... 3 General
More informationResidential Deck Safety, Construction, and Repair
Juneau Permit Center, 4 th Floor Marine View Center, (907)586-0770 This handout is designed to help you build your deck to comply with the 2006 International Residential Building code as modified by the
More informationEberl Iron Works, Inc.
Eberl Iron Works, Inc. Order Form Manual for Stair Pans, Stair Treads and Bent Plate NEW: VISIT US ONLINE AT WWW.STAIRPANS.COM Eberl Iron Works, Inc. 128 Sycamore St. Buffalo, NY 14204 Ph: 716-854-7633,
More informationBuyers Guide: Information required:
Buyers Guide: Information required: When ordering, please state: 1 Reference Number of Mesh (include any alphabetical suffix) Conventional/Flattened Mesh Dimensions: 1. For conventional (raised) meshes
More informationQuarry & Recycling Products
Quarry & Recycling Products CONTENTS Woven mesh screens Perforated screen plates Rubber & Polyurethane screens Walkways & Steps Ordering Information Further Information PAGE 3 6 8 9 10 11 Graepel has a
More informationIKG Bar Grating: Anchoring
IKG Bar Grating: Anchoring All bar grating must be tightly fastened in place. Welding of the grating panels to the supporting members provides a superior, permanent installation. Although, for gratings
More informationROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS
ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS 1. 2. 3. 3.0 Scope 1.1 This application standard shall be used where the authority having jurisdiction has adopted its use, and
More informationMechanical arms, belts and sheets
Car parks Mechanical arms, belts and sheets DETAIL ARM CAR PARK (mm) 5000 Platen 100x5mm Iron sheets 4mm 5000 485 2100 Belts type C 120x50x2 mm 4915 5400 Hot dipped galvanized UNE-EN ISO 1461 or black
More informationCable Trays Technical Instructions & Specifications
Cable Trays Technical Instructions & Specifications Products Catalogue Objective and Structure The company s main objective is the supply of quality products, with respect to: practical design increased
More informationOne-third of all fatalities in the U.S. construction
Guardrail systems: Fall prevention for floor and wall openings and open-sided floors One-third of all fatalities in the U.S. construction industry result from falls from elevations. Falls from elevations
More informationFabcograte FRP Grating. Tolerances: ±1/16. Tolerances: ±1/16. THICKNESS BAR SPACING PANEL SIZE (FT.) WT (LBS) 1" 1.5" x 1.
Features: Will not rust. Corrosion resistant. Non-sparking. Fire retardant. Non-conductive. Maintenance free. Molded-in color. Light weight. Easy to install. Impact resistant. Quality appearance. Fabcograte
More informationCT-02 CABLE TRAY SYSTEMS
CT-02 CABLE TRAY SYSTEMS SYSTEMS THAT MAKE SENSE Introduction B-Line Systems was formed in 96 and has over 30 years experience manufacturing cable tray systems in which it has grown to become the industry
More informationGUARDRAIL POST STEEL
GUARDRAIL POST STEEL Guardrail posts meeting materials certification are evaluated and checked for: 1. Dimensional acceptance 2. Physical test results a. Chemical b. Physical 3. Galvanized or painted coating
More informationSTANDARD SPECIFICATIONS SECTION 05500 METAL FABRICATIONS
STANDARD SPECIFICATIONS SECTION 05500 METAL FABRICATIONS PART 1 GENERAL 1.1 DESCRIPTION A. Section includes requirements for providing metal fabricated items like castings, gratings, hatchways, ladders,
More informationT&B Cable Tray. Metallic Aluminum. Straight Lengths. Tray Bottom Types Ladder, Ventilated and Solid Trough
Tray Bottom Types Ladder Extra wide aluminum rungs are welded to extruded aluminum I-beam siderails. Every second rung is reversed to allow for easy top or bottom mounting of cable ties and clamps. All
More informationDSM http://www.dsmmfg.com 1 (800) 886-6376
DESIGN GUIDE FOR BENT SHEET METAL This guide discusses how the bends are made, what thicknesses of sheet metal are commonly used, recommended bend radius to use when modeling the part, some practical limits
More informationLOADING DOCK EQUIPMENT. A. Section 03100 - Concrete Forms and Accessories: Placement of anchors into concrete.
LOADING DOCK EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES A. Loading dock equipment of the following types: 1. Dock lifts. 2. Control stations. 1.2 RELATED SECTIONS A. Section 03100 - Concrete Forms and
More informationFixed Access Ladders. Table of Contents. 1. Legislative Requirements
Fixed Access Ladders Engineering Data Sheet 2-04 Revised: January 1997 Table of Contents 1. Legislative Requirements 2. General 3. Rungs 4. Side Rails 5. Safety Cages 6. Attachment & Anchoring 7. Platforms
More informationRESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS
RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS The following guidelines are intended to assist with the permit acquisition process with regard to Plumbing Alterations. Not all information, or additional
More informationThis handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.
Residential Decks Community Development Department Building Inspections Division 5200 85 th Avenue North / Brooklyn Park, MN 55443 Phone: (763) 488-6379 / Fax: (763) 493-8171 6/15 www.brooklynpark.org
More informationSTANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES
ROOFING APPLICATION STANDARD (RAS) No. 117 STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES Scope 1.1.
More informationWELAND TERMINOLOGY LOAD BEARING BAR CROSS BAR GRATING TYPE SAF MESH OPENING GRATING. LENGTH, SPAN WIDTH or LENGTH OF LOAD BAR GRATING
GRATING Page Terminology 6-7 Pedestrian Walkway Multipanels from Stock 8-13 Duckboard 13 Vehicular Multipanels with Load Tables 14-15 Kerb Angle Frames 16-17 Entrance Mats 18-20 Special Grating 22 Mesh
More informationHow to secure your property after a disaster
How to secure your property after a disaster The Red Guide to Recovery HOuse secured properly Board-Up of Windows, Doors and Roof Hole. Lot secured with Perimeter Fencing. Fires, floods, tornadoes, hurricanes,
More informationOPTIONAL INFORMATION GUARDING FLOORS, STAIRS, AND OTHER OPENINGS SELF INSPECTION CHECKLIST
OPTIONAL INFORMATION Name of School: Date of Inspection: Vocational Program/Course/Room: Signature of Inspector: GUARDING FLOORS, STAIRS, AND OTHER OPENINGS Guidelines: This checklist covers some of the
More information1.02 SYSTEM DESCRIPTION
1 OF 7 MODULAR MEZZANINES GUIDE SPECIFICATIONS FOR PART 1 - GENERAL 1.01 RELATED WORK A. SECTION 03 30 00: Cast in Place Concrete (and Concrete Finishing) 1. The area where mezzanine is installed shall
More informationPRODUCT INDEX FLOORING HANDRAILING STAIRTREADS MISCELLANEOUS
FOORING PRODUCT INDEX AUMINIUM TREAD PATE 7 DURBAR STEE FOOR PATE 7 EXPANDED META AKAY MESH 5 GASS FIBRE FOORING AND FOOR PATE 8, 9 GRATING 5 OPEN STEE FOORING 4 RHINO FOORING PANKS 6, 7 SAFE OAD TABES
More information5 G R A TINGS ENGINEERING DESIGN MANUAL. MBG Metal Bar Grating METAL BAR GRATING MANUAL MBG 534-12 METAL BAR GRATING NAAMM
METAL BAR NAAMM GRATNG MANUAL MBG 534-12 5 G R A TNG NAAMM MBG 534-12 November 4, 2012 METAL BAR GRATNG ENGNEERNG DEGN MANUAL NAAMM MBG 534-12 November 4, 2012 5 G R A TNG MBG Metal Bar Grating A Division
More informationSECTION 15410 GROUND WATER STORAGE TANKS
SECTION 15410 GROUND WATER STORAGE TANKS PART 1 GENERAL.01 SCOPE A. Section Includes Requirements for designing, fabricating, and erecting a welded steel ground storage tank..02 SYSTEM DESCRIPTION A. Design
More informationLiftAlloy Chain Slings
CHAIN SLING BASICS Slings Lift-All chain slings meet or exceed all OSHA, ASME B30.9 and NACM standards and regulations. chain slings, available in 80 for 7/32" and 7/8"- /4" and 00 for 9/32"-3/4", are
More informationPIPING SYSTEM - ABRASIVE SLURRIES Engineering Standard Specification. 96 B. Riutta
PIPING SYSTEM - ABRASIVE SLURRIES Engineering Standard Specification Number: 3503-11.2.610 Rev. 2 Rubber Lined Steel Pipe and Fittings Mechanically Coupled Plain End Type System Issued Revised Approved
More informationMobile Home Pre-Inspection Checklist
Mobile Home Pre-Inspection Checklist TWO (2) STEP INSPECTION PROCESS STEP ONE: CALL FOR THE FIRST INSPECTION WHEN THESE ITEMS ARE COMPLETE. 1. Septic tank installed and plumbing complete. (SEE PLUMBING
More informationRESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings
More informationTABLE OF CONTENTS. Roof Decks 172 B, BA, BV Deck N, NA Deck. Form Decks 174.6 FD,.6 FDV Deck 1.0 FD, 1.0 FDV Deck 1.5 FD Deck 2.0 FD Deck 3.
Pages identified with the NMBS Logo as shown above, have been produced by NMBS to assist specifiers and consumers in the application of New Millennium Building Systems Deck products. Pages identified with
More information60.12. Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING
60.1 D-O-L FxE expansion couplings are a bolted, split-sleeve design that provides for expansion and contraction at the coupled joint. These couplings are furnished with restraint rings that, when affixed
More informationCHAIN-LINK FENCES BID SPECIFICATIONS DESCRIPTION
CHAIN-LINK FENCES BID SPECIFICATIONS DESCRIPTION 1 This item shall consist of furnishing and erecting Chain-Link fence in accordance with these specifications and the details shown on the plans and in
More informationFinal inspections are completed by site visit only. Access to fenced yards shall be planned.
ROOFING RESIDENTIAL BUILDING INSPECTIONS DEPARTMENT www.ci.blaine.mn.us This handout is intended only as a guide and is based in part on the 2015 Minnesota State Building Code, Blaine City ordinances,
More informationSports and High Mast Lighting Poles Phone: (866) 474-7200 Fax: (817) 924-7049
Sports and High Mast Lighting Poles 4 High Mast Lighting Poles General American LitePole offers a raising and lowering system that allows for ease of maintaining the lighting system at ground level. Ideal
More informationPerfection Spring & Stamping Corp. 1449 E. Algonquin Rd. Mount Prospect, IL 60056 USA www.pss-corp.com 411@pss-corp.com
Perfection Spring & Stamping Corp. 1449 E. Algonquin Rd. Mount Prospect, IL 60056 USA www.pss-corp.com 411@pss-corp.com Raw Material Type, Alloy, & Finishes By Manufacturing Method 1. Punch Press Department
More informationFRACASSO SCAFFOLDING PS 720
FRACASSO SCAFFOLDING PS 720 Characteristics Geometry Strengths PS 720 was designed and constructed in keeping with European regulations EN12810 and EN12811. 150 mm pin obtained by tapering the upright
More informationPUMP JACK SYSTEM AND ACCESSORIES
Pump Jack Model # 2200 A low cost, easy to operate, safe, portable scaffolding built of rugged steel. It's perfect for shingling, siding, sheathing, insulating, painting, building, roofing, home repair
More informationTwo most common lock nut groups: 1-Prevailing Torque Type Lock Nuts:
Two most common lock nut groups: 1. PREVAILING TORQUE a design feature of the lock nut produces friction between threads of mated components thereby increasing the force needed to tighten as well as loosen
More informationValu Guide Sheaths. Valu Guide Inserts. Optional Valu Guide Inserts. Typical Properties of Valu Guide Rail. and Hardware.
14 gauge stainless steel The Original, Long Life Sanitary Guide Rail Valu Guide rail incorporates two outstanding materials: stainless steel and UHMW. The 14 ga. stainless steel sheath provides rigid streamlined
More informationLathe Milling Attachment
Lathe Milling Attachment By L C. MASON BY CLEVERLY stacking cold-rolled flat stock together, T-slots and slide for this lathe milling attachment are made without costly machinery. In fact, only two tools,
More informationCALCULATION & DRAFTING STANDARDS MANUAL PROCEDURE: C&D 515 Bill of Materials Standard REV 0.0 5/6/04
BROWN MINNEAPOLIS TANK PAGE 1 OF 7 PURPOSE: Create and Drawing Uniformity Create, explain, and establish a standard bill of materials to be placed on every drawing (except the overall tank elevation and
More informationThe corrugated box: A profile and introduction
The corrugated box: A profile and introduction 1 More than just a plain brown box Ninety to ninety-five percent of U.S. manufactured goods are shipped to consumers in corrugated containers. In fact, more
More informationBoston, Venice, Kodiak. Enviro Wood Fireplace Inserts
Boston, Venice, Kodiak Enviro Wood Fireplace Inserts Why buy an Enviro Wood Insert? Up to 84.7% Efficiency - EPA approved and up to 84.7% efficiency - Enviro makes highly efficient wood inserts to help
More informationResidential Decks. Planning and Development Services Department
Building Safety Division 8500 Santa Fe Drive Overland Park, KS 66212 (913) 895-6225 Fax (913) 895-5016 Email: permitservices@opkansas.org Planning and Development Services Department Residential Decks
More informationWALKING-WORKING SURFACES (SLIPS, TRIPS, AND FALLS)
WALKING-WORKING SURFACES (SLIPS, TRIPS, AND FALLS) Slips, trips, and falls constitute the majority of general industry accidents. They cause 15% of all accidental deaths, and are second only to motor vehicles
More informationProduct Catalogue (updated Feb. 2010)
Product Catalogue (updated Feb. 2010) 315 BROCK RD GREENSVILLE ON L9H 5H7 PHONE: 905-628-0766 FAX: 905-628-8277 www.efcomltd.com info@efcomltd.com 1 Table of Contents Tool Boxes... 3 Cylinder Enclosures
More informationAnodes and Misc Equipment
Anodes and Misc Equipment Application: Platinised Titanium Anodes Platinised titanium anodes are recommended for use in the following electrolytic processes:- Precious metal electroplating - e.g. Au, Pt,
More informationDIY ALL STEEL SHED FRAMES
DIY ALL STEEL SHED FRAMES FAST FIT FRAMES & CONNECTOR PRICES BELOW THE BEST BUILDINGS START WITH A STEEL BUILDING FRAME ALLOW 10-21 WORKING DAYS FROM DATE ORDERED FOR PRODUCTION & SHIPMENT READY PRICES
More informationCable Support Solutions
Cable Support Solutions B-Line by Eaton Technology Day Japan 2013 2012 Eaton Corporation. All rights reserved. 2012 Eaton Corporation. All rights reserved. 2012 Eaton Corporation. All rights reserved.
More informationPreformed Metal Roofing and Siding
Page -1-1. GENERAL 1.1. Description This specification along with the drawings covers the furnishing of all material, products, equipment, accessories, tools, services, transportation, labor and supervision
More informationFRP Grating, Handrail, Guidelines for Ladders & the Engineer Structural and Designer Shapes
Guidelines for the Engineer and Designer FRP Grating, Handrail, Ladders & Structural Shapes Corrosion Resistant Fire Retardant Low Maintenance Long Service Life High Performance Composite Solutions 1.0
More informationMEZZANINE SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE 1.2 APPROVED MANUFACTURER 1.3 REGULATORY ORGANIZATIONS AND GROUPS 1.4 QUALITY ASSURANCE
MEZZANINE SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE This specification is intended to describe the general requirements applicable to a proper structural mezzanine design. In addition, it is to serve as
More informationSECTION 07 61 13 STANDING SEAM METAL ROOFING
SECTION 07 61 13 STANDING SEAM METAL ROOFING PART 1 GENERAL 1.01 SCOPE OF WORK A. The Work shall include all labor, materials, equipment and supervision required to complete the work of the above referenced
More informationWall braces with a swivel head are included to accommodate all roof pitches.
ULTRA JACK MODEL # 2000 Wall braces with a swivel head are included to accommodate all roof pitches. Product Specifications Model # 2000 Description: Ultra Jack Unit Pack: Weight per Pack: 1 / Carton 32
More informationSection 05 51 00 METAL STAIRS
150303 Page 1 Section 05 51 00 METAL STAIRS 1.0 GENERAL 1.1 SUMMARY A. Selection Includes: This Section specifies prefabricated metal stairs and railings. B. Related Requirements: 1) Section 03 30 00 Cast-in-Place
More informationCHAPTER 6 CONSTRUCTION TYPES
CHAPTER 6 CONSTRUCTION TYPES SECTION 601 GENERAL 601.1 Scope. Provisions of this chapter shall govern the classification of construction type by materials and fire resistance of its elements and the use
More informationWalking and Working Surface Checklist:
Walking and Working Surfaces Purpose: This information is presented to improve the level of safety in our operations, and to inform you that we will comply with the OSHA Standard 29 CFR 1910.23. Responsibility:
More informationSECTION 260536 - CABLE TRAYS. A. Continuous, rigid, welded steel or stainless steel wire mesh cable management system.
SECTION 260536 - CABLE TRAYS PART 1 - GENERAL SECTION INCLUDES: A. Continuous, rigid, welded steel or stainless steel wire mesh cable management system. B. Cable tray systems are defined to include, but
More informationSECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE
SECTION 15076 CEMENT-MORTAR LINED AND COATED (CML&C) STEEL PIPE PART 1 GENERAL 1.01 DESCRIPTION This section designates the requirements for steel pipe fabrication, test in shop, installation of steel
More informationSPECIFICATIONS FOR BOON EDAM TOMSED MODEL TUT-65TMB
SPECIFICATIONS FOR BOON EDAM TOMSED MODEL TUT-65TMB PRODUCT DESCRIPTION: BOON EDAM TOMSED MODEL TUT-65TMB STAINLESS STEEL BARCODE SCANNING ELECTRONIC REGISTERING TURNSTILE SCOPE OF OPERATION: A. The TUT-65TMB
More informationAIRPORT SECURITY FENCING. A. American Society for Testing and Materials (ASTM):
SECTION 02832 AIRPORT SECURITY FENCING PART 1-GENERAL 1.1 SUMMARY A. Section includes: Construct airport security chain-link fence and gate at specified areas and conforming lines, grades, details indicated
More informationWINDOW AND DOOR REPLACEMENT REQUIREMENTS
WINDOW AND DOOR REPLACEMENT REQUIREMENTS Should you have any questions after reading the following information, please call the Building Inspection Department at 651-439-4439 to discuss the topics of concern.
More informationIHSS-N1 WELDED HONEYCOMB CORE SPECIFICATION. Generated: Sergiy Papyshev Engineering. Approved: Don Prysi Manufacturing. Approved: Merzuk Ramic Quality
IHSS-N1 WELDED HONEYCOMB CORE SPECIFICATION Generated: Sergiy Papyshev Engineering Approved: Don Prysi Manufacturing Approved: Merzuk Ramic Quality Approved: Steven Barnett Administrative DATE DATE DATE
More informationSECTION 08 5656 GUARDA SECURITY WINDOW SCREENS
Page 1 of 5 SECTION 08 5656 GUARDA SECURITY WINDOW SCREENS Guarda Security Window Screens in this specification are appropriate for use in windows, storefronts, curtain walls, vents, and any other applications
More informationWalking/Work Surfaces Fall Protection Program
Reviewed: 10-2006 Walking/Work Surfaces Fall Protection Program It is the responsibility of all supervisors and/or administrators to implement this safety program. Their responsibility includes yearly,
More informationSECTION 14 20 10 - FREIGHT & PARKING GARAGE ELEVATORS PART I - GENERAL
SECTION 14 20 10 - FREIGHT & PARKING GARAGE PART I - GENERAL 1.1 SECTION INCLUDES [NOTE to AE: The following lists requirements that are specific to freight elevators. These requirements are in addition
More informationSolicitation DTFACN-11-R-00079 Attachment #9
These specs are only a general overview of the typical VOR Roof construction. These are for reference only. Each individual project will have its own specifications. 1 VOR Roof Projects IDIQ Solicitation
More informationIncludes specifications for: Surface Cleaning & Mounting Hardware.
Three-Part Specifications - Copyright 2014 - Nixalite of America Inc Bird Screen Welded Wire Mesh Barriers Includes specifications for: Surface Cleaning & Mounting Hardware. Nixalite offers full rolls
More informationFIRE-RESISTANCE RATINGS WITH STEEL JOISTS
FIRE-RESISTANCE RATINGS WITH STEEL JOISTS The Underwriters Laboratories (U.L.) Fire Resistance Directory lists hundreds of assemblies their fire resistance ratings. The Specifying Professional can choose
More informationLapping and Polishing Basics
Lapping and Polishing Basics Applications Laboratory Report 54 Lapping and Polishing 1.0: Introduction Lapping and polishing is a process by which material is precisely removed from a workpiece (or specimen)
More informationBafl-Sorb Sound Absorbing Ceiling Baffles
Bafl-Sorb Sound Absorbing Ceiling Baffles INC offers a complete line of Sound Absorbing Ceiling Baffles to compliment any environment. Our ceiling baffles are among the most cost-effective method of adding
More informationSpecifications, Product Testing and Terminology
Specifications, Product Testing and Terminology The following synopsis provides a review of various material and final product testing, which is performed on our products, as well as, many of our competitors.
More informationScope of EN 1090-1 Clarification Document
Scope of EN 1090-1 Clarification Document This document has been submitted to the European Commission as the UK view on the scope of EN 1090-1. After discussions, including with the European Technical
More informationSCOPE This guideline applies to all construction projects on Emory University properties, including renovation projects.
1762 Clifton Road, Suite 1200 Atlanta, Georgia 30322 (404) 727-5922 FAX: (404) 727-9778 FALL PROTECTION DESIGN AND CONSTRUCTION GUIDELINES PURPOSE The purpose of this guideline is to provide safe design
More informationCLEAR-DIVISIONS CENTERFOLD
CLEAR-DIVISIONS CENTERFOLD Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS CENTERFOLD moveable The yellow highlighted areas in
More informationSECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)
SECTION 08332 COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Counter Fire Doors. 1.2
More informationDetached accessory structures that contain no conditioned floor area are exempt.
RESIDENTIAL ROOFING PERMITS: A roofing permit is required for roofing of residential dwellings and garages in accordance with Section R105 of the International Residential Code. Updated 11/2013 City of
More informationDrum Dispensing Stations
Drum Dispensing Stations O Safely Dispense from 55 Gallon Drums over a Spill Compliant Sump. 1-2-and 4 drum models available Drums are securely held on racks by galvanized positioners Sump and frame constructed
More informationA. Air-Conditioning and Refrigeration Institute: 1. ARI 850 - Commercial and Industrial Air Filter Equipment.
SECTION 23 40 00 - HVAC AIR CLEANING DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Activated carbon filters. 2. Extended surface rigid air filter with synthetic media. 3. Disposable panel
More informationAdult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST Code References: 2012 IRC Section R325 (WAC 51-51) APPLICATION NUMBER:
Adult Family Home (AFH) LOCAL BUILDING INSPECTION CHECKLIST Code References: 2012 IRC Section R325 (WAC 51-51) APPLICATION NUMBER: SECTIONS 1, 2, 3, AND 4 MUST BE COMPLETED BY APPLICANT BEFORE INSPECTION
More informationStainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures
SX 8 The SX range comprises 14 sizes of enclosure manufactured in either stainless steel or mild steel. 11 sizes are available in depths of 140 or 200mm and 8 sizes are available in depths of 140, 200
More informationASTM A860/A860M-09 Standard Specification for Wrought High Strength. Ferritic Steel Butt Welding Fittings. 1. Scope :- 2. Reference Documents :-
Standard Specification for Wrought High Strength Ferritic Steel Butt Welding Fittings 1. Scope :- 1.1 This specification covers wrought high strength ferritic steel butt-welding fitting of seamless and
More informationIndex 20010 Series Prestressed Florida-I Beams (Rev. 07/12)
Index 20010 Series Prestressed Florida-I Beams (Rev. 07/12) Design Criteria AASHTO LRFD Bridge Design Specifications, 6th Edition; Structures Detailing Manual (SDM); Structures Design Guidelines (SDG)
More informationCat. No. Material Siderail Height. Designed to lock into place for easy alignment and installation. ABW-4-SSP
Metallic Snap-In Splice Plate Designed to lock into place for easy alignment and installation. Packaged in pairs with zinc plated hardware. Provided as standard with each straight and fitting. Cat. No.
More informationDesign No. P736 September 26, 2003. Restrained Assembly Ratings 1, 1-1/2 or 2 Hr. (See Items 3, 7 and 8A)
Design No. P736 September 26, 2003 Restrained Ratings 1, 1-1/2 or 2 Hr (See Items 3, 7 and 8A) Ratings 1, 1-1/2 or 2 Hr (See Items 3, 7 and 8A) Beam Ratings 1, 1-1/2 or 2 Hr (See Items 7 and 8A) 1. Beam
More informationSECTION 02630 STORM DRAINAGE SYSTEM
SECTION 02630 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes specifications for storm drainage systems including modifications and connections to existing storm drainage systems. 1.02 REFERENCE
More informationLightweight, Heavy Duty
Lightweight, Heavy Duty Trench Covers System Reliability The light weight combined with the tremendous strength of Comcore Trench Covers translates into speed, productivity and increased system reliability.
More informationSECTION 15140 - PIPE HANGERS AND SUPPORTS
Part I - GENERAL 1.01 SECTION INCLUDES A. The work covered under this section consists of the furnishing of all necessary labor, supervision, materials, equipment, and services to completely execute the
More informationTable of Contents. IV. Interior Doors. 1. Product Training 2. Bilco Quote/Order Checklist
Table of Contents IV. Interior Doors 1. Product Training 2. Bilco Quote/Order Checklist Interior Doors (non-drainage units) 1. Bilco T, TD, K, and KD Type doors A. T - single leaf aluminum construction
More informationUncovered Decks & Porches
Uncovered Decks & Porches Building Guides for Homeowners Why Do I need a Permit? D I D Y O U K N O W? As owner-builder you are the responsible party of record on such a permit. If your work is being performed
More informationSimplified Steel Stair Design for Commercial and Institutional Buildings
Simplified Steel Stair Design for Commercial and Institutional Buildings Collaborating with steel stair fabricators during the design of commercial and institutional buildings promotes integrated practice
More informationSECTION 4: Cable Ladder Stainless Steel & Aluminium
SECTION 4: Cable Ladder & Aluminium Type 3/50 (NEMA 6A) Type 4/70L Type 5/112 (NEMA 20C) > 4:3 > 4:4 > 4:5 Aluminium Type 4/70A (NEMA 16B) Ladder Splice Plates > 4:7 > 3:18 Page 4:1 Cable Ladder General
More information15 Cylinder Pallet. A CramerDecker Company. 800.752.4579 www.cramerdecker.com Fax 714.566.3869. For trailers and trucks with a tomb style receiver.
15 Cylinder Pallet For trailers and trucks with a tomb style receiver. and trailers compatible with many of the tomb and post style systems found in the industry. ProRack s cradle and manifold expertise
More information