Steel and Aluminum Utility Vent Sets
|
|
- Alexandrina Summers
- 7 years ago
- Views:
Transcription
1 CP
2 Steel and Aluminum Utility Vent Sets Page Introduction Standard Construction Features Specifications & Dimensions Belt Drives Backward Inclined Flat Blade Wheel: CPV (Aluminum Wheel / Steel Scroll) CPS (Steel Wheel / Steel Scroll) CPA (Aluminum Wheel / Aluminum Scroll) Backward Inclined Airfoil Wheel: CPS-A (Steel Wheel / Steel Scroll) CPA-A (Aluminum Wheel / Aluminum Scroll) Forward Curved Wheel: CPFB (Steel Wheel / Steel Scroll) Direct Drive Forward Curved Wheel: CPFD (Steel Wheel / Steel Scroll) Rotation & Discharge Construction Information UL Options Accessories Performance Data CPV, CPS, CPA, CPS-A & CPA-A CPFD CPFB Sound Data CPV CPS & CPA CPS-A & CPA-A CPFD & CPFB
3 INTRODUCTION Loren Cook Company CP centrifugal utility vent sets offer durability and reliability in a self-contained package. CP s are ideal for low to medium volume and pressure applications. They are available in a number of wheel options for maximum performance flexibility. Produced in an ISO Certified facility. Listed by Underwriters Laboratory (UL 5) and UL Listed for Canada (cul 5). Rotatable housing is standard on all models. Discharge flanges are standard on all belt drive models, except in downblast or bottom angular down discharge positions (see page 7). Belt Drives Backward Inclined Flat Blade Wheel: CPS, CPA & CPV Licensed to bear AMCA Certified Ratings Seals for Air and Sound Performance. UL/cUL listing for restaurant applications available. Steel Wheel / Steel Scroll (CPS) Aluminum Wheel / Aluminum Scroll (CPA) Wheel Sizes: - 49 Capacity: - 49,5 CFM Static Pressure: - 8 Class I or Class II (size - 365) CPA is Spark Resistant Type A construction (see page ) Aluminum Wheel / Steel Scroll (CPV) Wheel Sizes: - 49 Capacity: 5-43,4 CFM Static Pressure: -.5 CPV shown. All belt drive units use this body style. Backward Inclined Airfoil Wheel: CPS-A & CPA-A Licensed to bear AMCA Certified Ratings Seals for Air and Sound Performance. UL/cUL listing for restaurant applications available. Steel Wheel / Steel Scroll (CPS-A) Aluminum Wheel / Aluminum Scroll (CPA-A) Wheel Sizes: - 49 Capacity: - 53,55 CFM Static Pressure: - 8 Class I or Class II (size - 365) CPA-A is Spark Resistant Type A construction. (see page ) CPS-A is available with UL/cUL listing for Power Ventilator for Smoke Control Systems. Forward Curved Wheel: CPFB Licensed to bear AMCA Certified Ratings Seal for Air and Sound Performance. Steel Wheel / Steel Scroll (CPFB) Wheel Sizes: - 3 Capacity: 5-5, CFM Static Pressure: - Direct Drives Forward Curved Wheel: CPFD Steel Wheel / Steel Scroll (CPFD) Wheel Sizes: 6 - Capacity: 3 -,635 CFM Static Pressure: - The Wheels CPV uses a riveted aluminum wheel, with backward inclined flat blades. CPS uses a welded, Lorenized TM steel wheel, with backward inclined flat blades. CPA uses a welded, aluminum wheel. CPS-A uses a welded, Lorenized TM steel wheel, with backward inclined airfoil blades. CPA-A uses a welded, aluminum wheel. CPFD CPFD & CPFB use a steel wheel, with forward curved blades.
4 STANDARD CONSTRUCTION FEATURES About Centrifugal Fans A centrifugal wheel brings air in parallel to the axis of rotation and discharges air perpendicular to the axis of rotation. The air then follows the shape of the fan to the outlet. As a general rule, it is preferred for higher pressure exhaust and ducted systems. Shrowd Blade type: Backward Inclined Airfoil: Has the highest efficiency of all of the centrifugal impeller designs with blades of airfoil contour curved away from the direction of rotation. Air leaves the impeller at a velocity less than its tip speed. Relatively deep blades provide for efficient expansion with the blade passages. For the given duty, the airfoil impeller design will provide for the highest speed of the centrifugal fan designs. Backward Inclined Flat Blades: Efficiency is slightly less than that of the airfoil design. Blades are single thickness metal inclined away from the direction of rotation. Air leaves the impeller at a velocity less than its tip speed. Relatively deep blades provide efficient expansion with the blade passages. Backplate Blade Shown from the inlet side / opposite the drive shaft Forward Curved: Efficiency is less than airfoil and backward curved bladed impellers. Has blades with both the heel and tip curved forward. Air leaves the impeller at velocities greater than the impeller tip speed. For the given duty, the wheel is the smallest of all of the centrifugal types and operates most efficiently at lowest speed. Lorenized TM Powder Coating Lifting Lugs Scroll Housing Continuously Welded Housing Air-Handling Quality, Regreasable, Ball Bearings Flanged Field Rotatable Housing Adjustable Motor plate 3
5 CPV Specifications Centrifugal Vent Set Blower Backward Inclined Aluminum Wheel Steel Housing Belt Drive Loren Cook Company certifies that the CPV shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication and AMCA Publication 3 and comply with the requirements of the AMCA Certified Ratings Program. Type CPV is furnished standard with UL 5 listing ( C UL 5) when furnished with factory supplied motor. Type CPV is available with UL listing ( C UL ) when furnished with factory supplied motor. Description: Fan shall be a single width, single inlet, backward inclined flat blade, belt driven centrifugal vent set. Certifications: Fan shall be manufactured at an ISO certified facility. Fan shall be listed by Underwriters Laboratories (UL/cUL 5) for US and Canada. For restaurant applications, fan shall be listed by Underwriters Laboratories (UL/cUL ) for US and Canada. Fan shall bear the AMCA Certified Ratings Seal for Sound and Air performance. Construction: The fan shall be of bolted and welded construction utilizing corrosion resistant fasteners. The scroll wrapper shall be minimum 4 gauge steel and the scroll side panels shall be minimum gauge steel. The entire fan housing shall have continuously welded seams for leakproof operation. A performance cut-off shall be furnished to prevent the recirculation of air in the fan housing. The fan housing shall be field rotatable to any one of eight discharge positions and shall have a minimum -/ inch outlet discharge flange. Bearing support shall be minimum gauge welded steel. Side access inspection ports shall be provided with quick release latches for access to the motor compartment without removing the weather cover. Lifting lugs shall be provided for ease of installation. Unit shall bear an engraved aluminum nameplate. Nameplate shall indicate design CFM, static pressure, and maximum fan RPM. Unit shall be shipped in ISTA Certified Transit Tested Packaging. Coating: Steel fan components shall be Lorenized TM with an electrostatically applied, baked polyester powder coating. Each component shall be subject to a five stage environmentally friendly wash system, followed by a minimum mil thick baked powder finish. Paint must exceed, hour salt spray under ASTM B7 test method. Wheel: Wheel shall be centrifugal backward inclined, constructed of % aluminum, including a precision machined cast aluminum hub. Wheel hub shall be keyed and securely attached to the fan shaft. Wheel inlet shall overlap an aerodynamic aluminum inlet cone to provide maximum performance and efficiency. Wheel shall be balanced in accordance with AMCA Standard 4-5, Balance Quality and Vibration Levels for Fans. Motor: Motor shall be NEMA Design B with Class B insulation rated for continuous duty and furnished at the specified voltage, phase and enclosure. Blower Shaft: Blower shaft shall be AISI C-45 hot rolled and accurately turned, ground and polished. Shafting shall be sized for a critical speed of at least 5% of maximum RPM. Bearings: Bearings shall be designed and tested specifically for use in air handling applications. Construction shall be heavy duty regreasable ball or roller type in a cast iron pillowblock housing selected for a minimum L5 life in excess of, hours at maximum cataloged operating speed. Belts and Drives: Belts shall be oil and heat resistant, static conducting. Drives shall be precision machined cast iron type, keyed and securely attached to the wheel and motor shafts. Drives shall be sized for 5% of the installed motor horsepower. The variable pitch motor drive must be factory set to the specified fan RPM. Product: Fan shall be model CPV as manufactured by Loren Cook Company of Springfield, Missouri. 4
6 Dimensions CPV T Z Discharge L Centerline K Shaft Centerline -/" V E F V H D Weather Cover Optional R Q U J A ID U U X B ID P U C OD Y Y G S Dia. CPV Dimensions Size A B C D E F G H J K L M 6 7-9/6-5/6 4-/8 8 -/4-3/4 9-3/8 5-/4-3/4 -/4 3-/8 7-9/6-5/6 4-/8 8 -/4-3/4 9-3/8 5-/4-3/4 -/4 3-/8 7-9/6-5/6 4-/8 8 -/4-3/4 9-3/8 5-/4-3/4 -/4 3-/8 7-9/6-5/6 4-/8 8 -/4-3/4 9-3/8 5-/4-3/4 -/4 3-/8 9-3/6 3-/8 6-/ /6 3-3/8 9-3/8 6-/4-3/8-7/8 3-/8 35-5/6 4-3/4 7-5/8 8 6-/6 3-7/8 9-3/8 7 3-/ 3 5-/8 5-7/6 6-7/6 9-/8 9-/6 9-9/6 5-5/6 9-3/8 9-/6 4-5/8 4-/8 5-/8 65-5/8 8-/6-3/6-7/6 3-/6 6-3/8 9-3/8 3-7/6 5-3/6 5-5/6 5-/8 3-3/4 9-/6 -/6 -/6 34-3/4 7-5/8-3/8 33-9/6 6-5/6 6-7/6 5-/8 4-5/6-5/6 4-3/6 3-/6 36-5/6 7-3/6-3/8 35-/6 8-3/ /8 8-/8 6-/ /6 5-3/8 39-5/6-3/8 38-7/8 9-5/ /4 8-/ /6 4-5/8 7-7/ /8-7/8 4-7/ /8 8-/ /4 6-3/6 9-7/6 9-5/8 45-/6-3/4 3-3/8 44-5/ /6 8-/8-5/8 9-9/6 3-5/6 3-3/8 49-/6 3-3/8 4-3/8 48-7/8 4-7/ /6 -/8 3-5/6 3-3/6 34-5/6 35-5/8 54-3/8 5-7/8 5-5/6 53-5/8 7-3/ / /4 36-/8 37-5/6 38-7/8 59-3/6 8-7/6 6-3/6 58-3/8 9-7/ /6-3/ /8 39-5/6 4-7/6 4-3/4 -/8 3-7/6 7-3/6 64-/4 3-/6 3-5/6 4-3/ /4 44-/6 45-3/6 46-3/4-5/6 34-/6 9-3/6 -/4 34-5/6 34-5/6 4-3/ /6 49-7/6 5-3/8-9/6 38-5/6-3/6-7/8 38-3/ /6 8-3/ /6 53-5/ /4-3/4 4-3/6 3-3/6 -/4 4-5/ /6 G W M N G G Side Size N P Q R S T U V W X Y Z Max. Motor Frame * Ship Wt /8 3-3/8 3 3/4 9/6 3/4-5/ /6 8-5/8 4-5/8 45T /8 3-3/8 3 3/4 9/6 3/4-5/ /6 8-5/8 4-5/8 45T /8 3-3/8 3 3/4 9/6 3/4-5/ /6 8-5/8 4-5/8 45T /8 3-3/8 3 3/4 9/6 3/4-5/ /6 8-5/8 4-5/8 45T /6 3 3/4 9/6 3/4-5/ /6 8-5/8 5-7/6 T /8 34-3/6 3 3/4 9/6 3/4-5/ /6 8-5/8 6 T /4 37-/8 3 3/4 9/6 3/4-5/ /8 8-5/8 6-9/6 T /6 39-7/8 3 3/4 9/6 3/4-5/ /4 8-5/8 7-3/6 T /6 43-/8 3 9/6 3/4-5/ /8 9-5/8 7-3/4 5T /4 46-3/8 3 9/6 3/4-5/ / 9-5/8 8-5/6 5T 3 7-7/8 49-3/4 4 9/6 3/4-5/ /6-5/8 8-7/8 5T /6 3/4-5/8 -/ 5 7-3/6 -/8 9-7/6 5T /6 58-/4 4 /6 -/8 -/ 5 3-3/8 -/ 5T 57-5/6 63-3/4 4 /6 -/8 -/ /4 3-3/8-7/6 56T /6 7-/4 4-3/6 /6 -/8 3-/ /6-5/8 56T /8-3/4 4-3/6 3/6 -/ /6 5-3/6 3-3/4 56T /4 -/ 5-3/6 3/6 -/ /6 6-3/6 5-/6 34T 4 34-/8 -/ 5-7/6 3/6 -/ /6 8-3/6 7 34T /8-3/4 5-7/6 3/6 -/ /6-3/6 8-5/8 36T /6 -/ 5-7/6 3/6 -/ /8-3/6-3/8 36T 4 All dimensions in inches. Weight in lbs., less motor. For other discharge dimensions, please consult page 7, Compute-A-Fan, an authorized representative or the factory. *Based on open drip proof, single speed. 5
7 CPS Specifications Centrifugal Utility Vent Set Blower Backward Inclined Wheel Steel Construction Belt Drive Loren Cook Company certifies that the CPS shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication and AMCA Publication 3 and comply with the requirements of the AMCA Certified Ratings Program. Type CPS is furnished standard with UL 5 listing ( C UL 5) when furnished with factory supplied motor. Type CPS is available with UL listing ( C UL ) when furnished with factory supplied motor. Type CPS is available with UL Power Ventilator for Smoke Control Systems Listing when furnished with factory supplied motor. Description: Fan shall be a single width, single inlet, backward inclined flat blade, belt driven centrifugal vent set. Certifications: Fan shall be manufactured at an ISO certified facility. Fan shall be listed by Underwriters Laboratories (UL/cUL 5) for US and Canada. For restaurant applications, fan shall be listed by Underwriters Laboratories (UL/cUL ) for US and Canada. For smoke control applications, fan shall be listed by Underwriters Laboratories (Power Ventilator for Smoke Control Systems) for US and Canada. Fan shall bear the AMCA Certified Ratings Seal for Sound and Air performance. Construction: The fan shall be of bolted and welded construction utilizing corrosion resistant fasteners. The scroll wrapper shall be a minimum 4 gauge steel and the scroll side panels shall be a minimum gauge steel. The entire fan housing shall have continuously welded seams for leakproof operation. A performance cut-off shall be furnished to prevent the recirculation of air in the fan housing. The fan housing shall be field rotatable to any one of eight discharge positions and shall have a minimum -/ inch outlet discharge flange. Bearing support shall be minimum gauge welded steel. Side access inspection ports shall be provided with quick release latches for access to the motor compartment without removing the weather cover. Lifting lugs shall be provided for ease of installation. Unit shall bear an engraved aluminum nameplate. Nameplate shall indicate design CFM, static pressure, and maximum fan RPM. Unit shall be shipped in ISTA Certified Transit Tested Packaging. Coating: Steel fan components shall be Lorenized TM with an electrostatically applied, baked polyester powder coating. Each component shall be subject to a five stage environmentally friendly wash system, followed by a minimum mil thick baked powder finish. Paint must exceed, hour salt spray under ASTM B7 test method. Wheel: Wheel shall be steel centrifugal backward inclined, nonoverloading flat blade type. Blades shall be continuously welded to the backplate and deep spun inlet shroud. Wheel hub shall be keyed and securely attached to the fan shaft. Wheel inlet shall overlap an aerodynamic aluminum inlet cone to provide maximum performance and efficiency. Wheel shall be balanced in accordance with AMCA Standard 4-5, Balance Quality and Vibration Levels for Fans. Motor: Motor shall be NEMA Design B with Class B insulation rated for continuous duty and furnished at the specified voltage, phase and enclosure. Bearings: Bearings shall be designed and tested specifically for use in air handling applications. Construction shall be heavy duty regreasable ball or roller type in a cast iron pillowblock housing selected for a minimum L5 life in excess of, hours at maximum cataloged operating speed. Blower Shaft: Blower shaft shall be AISI C-45 hot rolled and accurately turned, ground and polished. Shafting shall be sized for a critical speed of at least 5% of maximum RPM. Belts and Drives: Belts shall be oil and heat resistant, static conducting. Drives shall be precision machined cast iron type, keyed and securely attached to the wheel and motor shafts. Drives shall be sized for 5% of the installed motor horsepower. The variable pitch motor drive must be factory set to the specified fan RPM. Product: Fan shall be model CPS as manufactured by Loren Cook Company of Springfield, Missouri. 6
8 Dimensions CPS T Z Discharge L Centerline K Shaft Centerline -/" V E F V H D Weather Cover Optional R Q U J A ID U U X B ID P U C OD Y Y G G W M N AA AA S Dia. Side CPS Dimensions Size A B C D G H K L M N E F J Class I Class II Class I Class II Class I Class II Class IClass II Class I Class II Class I Class II Class I Class II 6 7-9/6-5/6 4-/8 8 -/4-3/4 9-3/8 5-/4-3/4 -/4 3-/8 9-3/8 7-9/6-5/6 4-/8 8 -/4-3/4 9-3/8 5-/4-3/4 -/4 3-/8 9-3/ /6-5/6 4-/8 8 -/4-3/4 9-3/8 5-/4-3/4 -/4 3-/8 9-3/8-7-9/6-5/6 4-/8 8 -/4-3/4 9-3/8 5-/4-3/4 -/4 3-/8 9-3/8 9-3/6 3-/8 6-/ /6 3-3/8 9-3/8-3/8 6-/4 3-/4-3/8 8-7/8-5/6 3-/8 -/8 -/4 35-5/6 4-3/4 7-5/8 8 6-/6 3-7/8 9-3/8-3/ / /6 5-/8 -/8 -/8-3/8 5-7/6 6-7/6 9-/8 9-/6 9-9/6 5-5/6 9-3/8-7/8 9-/ /8 8 4-/8 4-9/6 5-/8 -/8 3-/4 3-/ 65-5/8 8-/6-3/6-7/6 4 3-/6 6-3/8 9-3/ / /6 -/8 5-5/6 6-/8 5-/8 5-/4 4-7/6 5-/6 3-3/4 9-/6-/6 -/ /4 7-5/8-3/ /6 35-/ 6-5/6 -/8 6-7/6 7-/4 5-/8 5-/4 5-9/6 6-3/6 4-5/6-5/6 4-3/6 3-/6 4-/4 36-5/6 7-3/6-3/8 3-3/4 35-/6 36-/4 8-3/6 5 -/8 7-5/8 8-/ 8-/8 5-/4 6-3/4 7-3/8 6-/ /6 5-3/8 5-3/8 39-5/6-3/8 3-3/4 38-7/ /6 5 -/8 8-3/4 9-5/8 8-/8 5-/4 7-7/8 8-/ 5 7-3/6 4-5/8 7-7/ /8-7/8 3-7/ /6 5 -/8 9-7/8-7/8 8-/8 5-/ / /4 6-3/6 9-7/6 9-5/8 9-5/8 45-/6-3/4 3-3/8 4-5/6 44-5/8 44-5/ /8 -/6-5/6 8-/8 7-5/6 -/6-5/6-5/8 9-9/6 3-5/6 3-3/8 3-3/8 49-/6 3-3/8 4-3/8 5-7/6 48-7/8 48-7/8 4-7/8 8 4-/8 3-9/6 4-/6 -/8 7-5/6-5/63-/6 3-5/63-3/634-5/6 35-5/8 35-5/8 54-3/8 5-7/8 5-5/6 6-/6 53-5/8 53-5/8 7-3/ /6-3/69-3/6 5-5/6 6-3/ /4 36-/8 37-5/6 38-7/8 38-7/8 59-3/6 8-7/6 6-3/6 7-5/8 58-3/8 58-3/8 9-7/ /6 9-9/6-3/69-3/6 7-5/8 8-9/ /8 39-5/6 4-7/6 4-3/4 4-3/4 -/8 3-7/6 7-3/-3/6 64-/4 64-/4 3-/ /6 3-7/6 4-3/6 9-/4 3-/4 3-7/ /4 44-/6 45-3/6 46-3/4-5/634-/-3/6 -/4 34-5/6 34-5/6 4-3/6 34-/ /6 49-7/6 5-3/8 - -9/6 38-5/6-3/6 - -7/8-38-3/ /6-8-3/6-37-3/ /6 53-5/ /4-3/4 4-3/6 3-3/6 -/4 4-5/ /6 4-3/6 P R V Y Z AA Max. Motor Size Q S T U W X Frame * Ship Wt. Class I Class II Class I Class II Class I Class II Class I Class II Class I Class II Class I Class II Class I Class II Class I Class II 6 3-3/8 3 9/6 3/4-5/ /6 8-5/8 4-5/8 9-3/8 45T 3-3/8 3 9/6 3/4-5/ /6 8-5/8 4-5/8 9-3/8 45T /8 3 9/6 3/4-5/ /6 8-5/8 4-5/8 9-3/8 45T - 3-3/8 3 9/6 3/4-5/ /6 8-5/8 4-5/8 9-3/8 45T 3-9/6 36-3/4 3-7/6 9/6 3/4-5/ /6 8-5/8 9-5/8 5-7/6 5-9/6 9-3/8 -/ T 5T /6 38-3/8 3-7/6 9/6 3/4-5/ /6 8-5/8 9-5/8 6 6-/8 9-3/8-7/6 T 5T /8 4-/4 3-7/6 9/6 3/4-5/8 8 9-/ 4 9-5/8 8-5/8 -/8 6-9/6 6-/6 9-3/8-5/6 T 56T /8 43-5/8 3-7/6 9/6 3/4-5/8 8 -/4 4 -/4 8-5/8 -/4 7-3/6 7-5/8 9-3/8 3-/6 T 56T /8 45-/4 3-3/6 -/6 9/6 3/4-5/8 9 -/4 4-7/8 9-5/8 -/4 7-3/4 8-3/6-3/8 3-/6 5T 56T /8 47-/8 3-3/6 -/6 9/6 3/4-5/ / 9-5/ /6 8-3/6-3/8 3-7/8 5T 56T /4 49-5/6 4-7/6 -/6 9/6 3/4-5/ /6-5/ /8 9-3/8-3/8 3-7/8 5T 56T /6 4-7/6 -/6 9/6 3/4-5/8 -/ -/ /6 -/8 3-/8 9-7/6 -/6-7/8 4-/8 5T 56T /4 58-7/6 4 -/6-5/6 /6 -/8 -/ 3-/ /8 3-5/6 -/ -5/8 3-3/8 4-5/6 5T 56T /4 63-5/6 4 -/6-5/6 /6 -/8 -/ 3-/ /4 3-3/8 4-7/6-7/6 -/6 4-3/8 5-/6 56T T 3 7-/4 -/ 4-5/6-3/6 /6 -/8 3-/ 3-/ /6 5-/6-5/8 3-5/6 5-5/6 6-5/6 56T T /4 4-5/6-3/6 3/6 -/8 5 5-/ /6 5-3/6 6-5/8 3-3/4 4-9/6 6-3/6 8 56T 36T / -3/4 5-3/6-7/6 3/6 -/ / /6 6-3/6 7-3/6 5-/6 6-/8 7-3/6 9-3/8 34T 36T / 5-3/6 3/6 -/ /6 8-3/ /6 34T /4-5 -7/6-3/6 -/ /6-3/6-8-5/8 - -3/6-36T / 5-7/6 3/6 -/ /8-3/6-3/8 3-3/6 36T 39 All dimensions in inches. Weight in lbs., less motor. For other discharge dimensions, please consult page 7, Compute-A-Fan, an authorized representative or the factory. *Based on open drip proof, single speed. 7
9 CPA Specifications Centrifugal Utility Vent Set Blower Backward Inclined Wheel Aluminum Wheel and Housing Belt Drive Loren Cook Company certifies that the CPA shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication and AMCA Publication 3 and comply with the requirements of the AMCA Certified Ratings Program. Type CPA is furnished standard with UL 5 listing ( C UL 5) when furnished with factory supplied motor. Type CPA is available with UL listing ( C UL ) when furnished with factory supplied motor. Description: Fan shall be a single width, single inlet, backward inclined flat blade, belt driven centrifugal vent set featuring spark resistant Type A construction. Certifications: Fan shall be manufactured at an ISO certified facility. Fan shall be listed by Underwriters Laboratories (UL/cUL 5) for US and Canada. For restaurant applications, fan shall be listed by Underwriters Laboratories (UL/cUL) for US and Canada. Fan shall bear the AMCA Certified Ratings Seal for Sound and Air performance. Construction: The fan shall be of bolted and welded construction utilizing corrosion resistant fasteners. The scroll wrapper shall be minimum." aluminum and the scroll side panels shall be minimum." aluminum. The entire fan housing shall have continuously welded seams for leakproof operation. A performance cut-off shall be furnished to prevent the recirculation of air in the fan housing. The fan housing shall be field rotatable to any one of eight discharge positions and shall have a minimum -/ inch outlet discharge flange. Bearing support shall be minimum gauge welded steel. Side access inspection ports shall be provided with quick release latches for access to the motor compartment without removing the weather cover. Lifting lugs shall be provided for ease of installation. Unit shall bear an engraved aluminum nameplate. Nameplate shall indicate design CFM, static pressure, and maximum fan RPM. Unit shall be shipped in ISTA Certified Transit Tested Packaging. Coating: Steel fan components shall be Lorenized TM with an electrostatically applied, baked polyester powder coating. Each powder coated component shall be subject to a five stage environmentally friendly wash system, followed by a minimum mil thick baked powder finish. Paint must exceed, hour salt spray under ASTM B7 test method. Wheel: Wheel shall be aluminum centrifugal backward inclined, nonoverloading flat blade type. Blades shall be continuously welded to the backplate and deep spun inlet shroud. Wheel hub shall be keyed and securely attached to the fan shaft. Wheel inlet shall overlap an aerodynamic aluminum inlet cone to provide maximum performance and efficiency. Wheel shall be balanced in accordance with AMCA Standard 4-5, Balance Quality and Vibration Levels for Fans. Motor: Motor shall be NEMA Design B with Class B insulation rated for continuous duty and furnished at the specified voltage, phase and enclosure. Bearings: Bearings shall be designed and tested specifically for use in air handling applications. Construction shall be heavy duty regreasable ball or roller type in a cast iron pillowblock housing selected for a minimum L5 life in excess of, hours at maximum cataloged operating speed. Blower Shaft: Blower shaft shall be Type 36 Stainless Steel accurately turned, ground and polished. Shafting shall be sized for a critical speed of at least 5% of maximum RPM. Belts and Drives: Belts shall be oil and heat resistant, static conducting. Drives shall be precision machined cast iron type, keyed and securely attached to the wheel and motor shafts. Drives shall be sized for 5% of the installed motor horsepower. The variable pitch motor drive must be factory set to the specified fan RPM. Product: Fan shall be model CPA as manufactured by Loren Cook Company of Springfield, Missouri. 8
10 Dimensions CPA K T Z Discharge L Centerline Shaft Centerline -/" V E F V H D Weather Cover Optional R Q U J A ID U U X B ID P U C OD Y Y G G W M N AA AA CPA Dimensions S Dia. Side Size A B C D G H K L M N E F J Class I Class II Class I Class II Class I Class II Class IClass II Class I Class II Class I Class II Class I Class II 6 7-9/6-5/6 4-/8 8 -/4-3/4 9-3/8 5-/4-3/4 -/4 3-/8 9-3/8 7-9/6-5/6 4-/8 8 -/4-3/4 9-3/8 5-/4-3/4 -/4 3-/8 9-3/ /6-5/6 4-/8 8 -/4-3/4 9-3/8 5-/4-3/4 -/4 3-/8 9-3/8-7-9/6-5/6 4-/8 8 -/4-3/4 9-3/8 5-/4-3/4 -/4 3-/8 9-3/8 9-3/6 3-/8 6-/ /6 3-3/8 9-3/8-3/8 6-/4 3-/4-3/8 8-7/8-5/6 3-/8 -/8 -/4 35-5/6 4-3/4 7-5/8 8 6-/6 3-7/8 9-3/8-3/ / /6 5-/8 -/8 -/8-3/8 5-7/6 6-7/6 9-/8 9-/6 9-9/6 5-5/6 9-3/8-7/8 9-/ /8 8 4-/8 4-9/6 5-/8 -/8 3-/4 3-/ 65-5/8 8-/6-3/6-7/6 4 3-/6 6-3/8 9-3/ / /6 -/8 5-5/6 6-/8 5-/8 5-/4 4-7/6 5-/6 3-3/4 9-/6-/6 -/ /4 7-5/8-3/ /6 35-/ 6-5/6 -/8 6-7/6 7-/4 5-/8 5-/4 5-9/6 6-3/6 4-5/6-5/6 4-3/6 3-/6 4-/4 36-5/6 7-3/6-3/8 3-3/4 35-/6 36-/4 8-3/6 5 -/8 7-5/8 8-/ 8-/8 5-/4 6-3/4 7-3/8 6-/ /6 5-3/8 5-3/8 39-5/6-3/8 3-3/4 38-7/ /6 5 -/8 8-3/4 9-5/8 8-/8 5-/4 7-7/8 8-/ 5 7-3/6 4-5/8 7-7/ /8-7/8 3-7/ /6 5 -/8 9-7/8-7/8 8-/8 5-/ / /4 6-3/6 9-7/6 9-5/8 9-5/8 45-/6-3/4 3-3/8 4-5/6 44-5/8 44-5/ /8 -/6-5/6 8-/8 7-5/6 -/6-5/6-5/8 9-9/6 3-5/6 3-3/8 3-3/8 49-/6 3-3/8 4-3/8 5-7/6 48-7/8 48-7/8 4-7/8 8 4-/8 3-9/6 4-/6 -/8 7-5/6-5/63-/6 3-5/63-3/634-5/6 35-5/8 35-5/8 54-3/8 5-7/8 5-5/6 6-/6 53-5/8 53-5/8 7-3/ /6-3/69-3/6 5-5/6 6-3/ /4 36-/8 37-5/6 38-7/8 38-7/8 59-3/6 8-7/6 6-3/6 7-5/8 58-3/8 58-3/8 9-7/ /6 9-9/6-3/69-3/6 7-5/8 8-9/ /8 39-5/6 4-7/6 4-3/4 4-3/4 -/8 3-7/6 7-3/-3/6 64-/4 64-/4 3-/ /6 3-7/6 4-3/6 9-/4 3-/4 3-7/ /4 44-/6 45-3/6 46-3/4-5/634-/-3/6 -/4 34-5/6 34-5/6 4-3/6 34-/ /6 49-7/6 5-3/8 - -9/6 38-5/6-3/6 - -7/8-38-3/ /6-8-3/6-37-3/ /6 53-5/ /4-3/4 4-3/6 3-3/6 -/4 4-5/ /6 4-3/6 P R V Y Z AA Max. Motor Size Q S T U W X Frame * Ship Wt. Class I Class II Class I Class II Class I Class II Class I Class II Class I Class II Class I Class II Class I Class II Class I Class II 6 3-3/8 3 9/6 3/4-5/ /6 8-5/8 4-5/8 9-3/8 45T 8 3-3/8 3 9/6 3/4-5/ /6 8-5/8 4-5/8 9-3/8 45T /8 3 9/6 3/4-5/ /6 8-5/8 4-5/8 9-3/8 45T 8-3-3/8 3 9/6 3/4-5/ /6 8-5/8 4-5/8 9-3/8 45T 8 3-9/6 36-3/4 3-7/6 9/6 3/4-5/ /6 8-5/8 9-5/8 5-7/6 5-9/6 9-3/8 -/ T 5T /6 38-3/8 3-7/6 9/6 3/4-5/ /6 8-5/8 9-5/8 6 6-/8 9-3/8-7/6 T 5T /8 4-/4 3-7/6 9/6 3/4-5/8 8 9-/ 4 9-5/8 8-5/8 -/8 6-9/6 6-/6 9-3/8-5/6 T 56T /8 43-5/8 3-7/6 9/6 3/4-5/8 8 -/4 4 -/4 8-5/8 -/4 7-3/6 7-5/8 9-3/8 3-/6 T 56T /8 45-/4 3-3/6 -/6 9/6 3/4-5/8 9 -/4 4-7/8 9-5/8 -/4 7-3/4 8-3/6-3/8 3-/6 5T 56T /8 47-/8 3-3/6 -/6 9/6 3/4-5/ / 9-5/ /6 8-3/6-3/8 3-7/8 5T 56T /4 49-5/6 4-7/6 -/6 9/6 3/4-5/ /6-5/ /8 9-3/8-3/8 3-7/8 5T 56T /6 4-7/6 -/6 9/6 3/4-5/8 -/ -/ /6 -/8 3-/8 9-7/6 -/6-7/8 4-/8 5T 56T /4 58-7/6 4 -/6-5/6 /6 -/8 -/ 3-/ /8 3-5/6 -/ -5/8 3-3/8 4-5/6 5T 56T /4 63-5/6 4 -/6-5/6 /6 -/8 -/ 3-/ /4 3-3/8 4-7/6-7/6 -/6 4-3/8 5-/6 56T T /4 -/ 4-5/6-3/6 /6 -/8 3-/ 3-/ /6 5-/6-5/8 3-5/6 5-5/6 6-5/6 56T T /4 4-5/6-3/6 3/6 -/8 5 5-/ /6 5-3/6 6-5/8 3-3/4 4-9/6 6-3/6 8 56T 36T / -3/4 5-3/6-7/6 3/6 -/ / /6 6-3/6 7-3/6 5-/6 6-/8 7-3/6 9-3/8 34T 36T / 5-3/6 3/6 -/ /6 8-3/ /6 34T /4-5 -7/6-3/6 -/ /6-3/6-8-5/8 - -3/6-36T / 5-7/6 3/6 -/ /8-3/6-3/8 3-3/6 36T 44 All dimensions in inches. Weight in lbs., less motor. For other discharge dimensions, please consult page 7, Compute-A-Fan, an authorized representative or the factory. *Based on open drip proof, single speed. 9
11 CPS-A Specifications Centrifugal Utility Vent Set Blower Airfoil Wheel Steel Construction Belt Drive Loren Cook Company certifies that the CPS-A shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication and AMCA Publication 3 and comply with the requirements of the AMCA Certified Ratings Program. Type CPS-A is furnished standard with UL 5 listing ( C UL 5) when furnished with factory supplied motor. Type CPS-A is available with UL listing ( C UL ) when furnished with factory supplied motor. Type CPS-A is available with UL Power Ventilator for Smoke Control Systems Listing when furnished with factory supplied motor. Description: Fan shall be a single width, single inlet, backward inclined airfoil, belt driven centrifugal vent set. Certifications: Fan shall be manufactured at an ISO certified facility. Fan shall be listed by Underwriters Laboratories (UL/cUL 5) for US and Canada. For restaurant applications, fan shall be listed by Underwriters Laboratories (UL/cUL ) for US and Canada. For smoke control applications, fan shall be listed by Underwriters Laboratories (Power Ventilator for Smoke Control Systems) for US and Canada. Fan shall bear the AMCA Certified Ratings Seal for Sound and Air performance. Construction: The fan shall be of bolted and welded construction utilizing corrosion resistant fasteners. The scroll wrapper shall be a minimum 4 gauge steel and the scroll side panels shall be a minimum gauge steel. The entire fan housing shall have continuously welded seams for leakproof operation. A performance cut-off shall be furnished to prevent the recirculation of air in the fan housing. The fan housing shall be field rotatable to any one of eight discharge positions and shall have a minimum -/ inch outlet discharge flange. Bearing support shall be minimum gauge welded steel. Side access inspection ports shall be provided with quick release latches for access to the motor compartment without removing the weather cover. Lifting lugs shall be provided for ease of installation. Unit shall bear an engraved aluminum nameplate. Nameplate shall indicate design CFM, static pressure, and maximum fan RPM. Unit shall be shipped in ISTA Certified Transit Tested Packaging. Coating: Steel fan components shall be Lorenized TM with an electrostatically applied, baked polyester powder coating. Each component shall be subject to a five stage environmentally friendly wash system, followed by a minimum mil thick baked powder finish. Paint must exceed, hour salt spray under ASTM B7 test method. Wheel: Wheel shall be steel centrifugal airfoil blade type. Blades shall be continuously welded to the backplate and deep spun inlet shroud. Wheel hub shall be keyed and securely attached to the fan shaft. Wheel inlet shall overlap an aerodynamic aluminum inlet cone to provide maximum performance and efficiency. Wheel shall be balanced in accordance with AMCA Standard 4-5, Balance Quality and Vibration Levels for Fans. Motor: Motor shall be NEMA Design B with Class B insulation rated for continuous duty and furnished at the specified voltage, phase and enclosure. Bearings: Bearings shall be designed and tested specifically for use in air handling applications. Construction shall be heavy duty regreasable ball or roller type in a cast iron pillowblock housing selected for a minimum L5 life in excess of, hours at maximum cataloged operating speed. Blower Shaft: Blower shaft shall be AISI C-45 hot rolled and accurately turned, ground and polished. Shafting shall be sized for a critical speed of at least 5% of maximum RPM. Belts and Drives: Belts shall be oil and heat resistant, static conducting. Drives shall be precision machined cast iron type, keyed and securely attached to the wheel and motor shafts. Drives shall be sized for 5% of the installed motor horsepower. The variable pitch motor drive must be factory set to the specified fan RPM. Product: Fan shall be model CPS-A as manufactured by Loren Cook Company of Springfield, Missouri.
12 Dimensions CPS-A K T Z Discharge L Centerline Shaft Centerline -/" V E F V D H Weather Cover Optional R Q U J A ID U U X B ID P U C OD Y Y G S Dia. G W M N AA AA Side CPS-A Dimensions Size A B C D G H K L M N E F J Class I Class II Class I Class II Class I Class II Class IClass II Class I Class II Class I Class II Class I Class II 9-3/6 3-/8 6-/ /6 3-3/8 9-3/8-3/8 6-/4 3-/4-3/8 8-7/8-5/6 3-/8 -/8 -/4 35-5/6 4-3/4 7-5/8 8 6-/6 3-7/8 9-3/8-3/ / /6 5-/8 -/8 -/8-3/8 5-7/6 6-7/6 9-/8 9-/6 9-9/6 5-5/6 9-3/8-7/8 9-/ /8 8 4-/8 4-9/6 5-/8 -/8 3-/4 3-/ 65-5/8 8-/6-3/6-7/6 4 3-/6 6-3/8 9-3/ / /6 -/8 5-5/6 6-/8 5-/8 5-/4 4-7/6 5-/6 3-3/4 9-/6-/6 -/ /4 7-5/8-3/ /6 35-/ 6-5/6 -/8 6-7/6 7-/4 5-/8 5-/4 5-9/6 6-3/6 4-5/6-5/6 4-3/6 3-/6 4-/4 36-5/6 7-3/6-3/8 3-3/4 35-/6 36-/4 8-3/6 5 -/8 7-5/8 8-/ 8-/8 5-/4 6-3/4 7-3/8 6-/ /6 5-3/8 5-3/8 39-5/6-3/8 3-3/4 38-7/ /6 5 -/8 8-3/4 9-5/8 8-/8 5-/4 7-7/8 8-/ 5 7-3/6 4-5/8 7-7/ /8-7/8 3-7/ /6 5 -/8 9-7/8-7/8 8-/8 5-/ / /4 6-3/6 9-7/6 9-5/8 9-5/8 45-/6-3/4 3-3/8 4-5/6 44-5/8 44-5/ /8 -/6-5/6 8-/8 7-5/6 -/6-5/6-5/8 9-9/6 3-5/6 3-3/8 3-3/8 49-/6 3-3/8 4-3/8 5-7/6 48-7/8 48-7/8 4-7/8 8 4-/8 3-9/6 4-/6 -/8 7-5/6-5/63-/6 3-5/63-3/634-5/6 35-5/8 35-5/8 54-3/8 5-7/8 5-5/6 6-/6 53-5/8 53-5/8 7-3/ /6-3/69-3/6 5-5/6 6-3/ /4 36-/8 37-5/6 38-7/8 38-7/8 59-3/6 8-7/6 6-3/6 7-5/8 58-3/8 58-3/8 9-7/ /6 9-9/6-3/69-3/6 7-5/8 8-9/ /8 39-5/6 4-7/6 4-3/4 4-3/4 -/8 3-7/6 7-3/-3/6 64-/4 64-/4 3-/ /6 3-7/6 4-3/6 9-/4 3-/4 3-7/ /4 44-/6 45-3/6 46-3/4-5/634-/-3/6 -/4 34-5/6 34-5/6 4-3/6 34-/ /6 49-7/6 5-3/8 - -9/6 38-5/6-3/6 - -7/8-38-3/ /6-8-3/6-37-3/ /6 53-5/ /4-3/4 4-3/6 3-3/6 -/4 4-5/ /6 4-3/6 P R V Y Z AA Max. Motor Size Q S T U W X Frame * Ship Wt. Class I Class II Class I Class II Class I Class II Class I Class II Class I Class II Class I Class II Class I Class II Class I Class II 3-9/6 36-3/4 3-7/6 9/6 3/4-5/ /6 8-5/8 9-5/8 5-7/6 5-9/6 9-3/8 -/ T 5T /6 38-3/8 3-7/6 9/6 3/4-5/ /6 8-5/8 9-5/8 6 6-/8 9-3/8-7/6 T 5T /8 4-/4 3-7/6 9/6 3/4-5/8 8 9-/ 4 9-5/8 8-5/8 -/8 6-9/6 6-/6 9-3/8-5/6 T 56T /8 43-5/8 3-7/6 9/6 3/4-5/8 8 -/4 4 -/4 8-5/8 -/4 7-3/6 7-5/8 9-3/8 3-/6 T 56T /8 45-/4 3-3/6 -/6 9/6 3/4-5/8 9 -/4 4-7/8 9-5/8 -/4 7-3/4 8-3/6-3/8 3-/6 5T 56T /8 47-/8 3-3/6 -/6 9/6 3/4-5/ / 9-5/ /6 8-3/6-3/8 3-7/8 5T 56T /4 49-5/6 4-7/6 -/6 9/6 3/4-5/ /6-5/ /8 9-3/8-3/8 3-7/8 5T 56T /6 4-7/6 -/6 9/6 3/4-5/8 -/ -/ /6 -/8 3-/8 9-7/6 -/6-7/8 4-/8 5T 56T /4 58-7/6 4 -/6-5/6 /6 -/8 -/ 3-/ /8 3-5/6 -/ -5/8 3-3/8 4-5/6 5T 56T /4 63-5/6 4 -/6-5/6 /6 -/8 -/ 3-/ /4 3-3/8 4-7/6-7/6 -/6 4-3/8 5-/6 56T T /4 -/ 4-5/6-3/6 /6 -/8 3-/ 3-/ /6 5-/6-5/8 3-5/6 5-5/6 6-5/6 56T T /4 4-5/6-3/6 3/6 -/8 5 5-/ /6 5-3/6 6-5/8 3-3/4 4-9/6 6-3/6 8 56T 36T / -3/4 5-3/6-7/6 3/6 -/ / /6 6-3/6 7-3/6 5-/6 6-/8 7-3/6 9-3/8 34T 36T 4 -/ 5-3/6 3/6 -/ /6 8-3/ /6 34T /4-5 -7/6-3/6 -/ /6-3/6-8-5/8 - -3/6-36T / 5-7/6 3/6 -/ /8-3/6-3/8 3-3/6 36T 3 All dimensions in inches. Weight in lbs., less motor. For other discharge dimensions, please consult page 7, Compute-A-Fan, an authorized representative or the factory. *Based on open drip proof, single speed.
13 CPA-A Specifications Centrifugal Utility Vent Set Blower Airfoil Wheel Aluminum Wheel and Housing Belt Drive Loren Cook Company certifies that the CPA-A shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication and AMCA Publication 3 and comply with the requirements of the AMCA Certified Ratings Program. Type CPA-A is furnished standard with UL 5 listing ( C UL 5) when furnished with factory supplied motor. Type CPA-A is available with UL listing ( C UL ) when furnished with factory supplied motor. Description: Fan shall be a single width, single inlet, backward inclined airfoil, belt driven centrifugal vent set featuring spark resistant Type A construction. Certifications: Fan shall be manufactured at an ISO certified facility. Fan shall be listed by Underwriters Laboratories (UL/cUL 5) for US and Canada. For restaurant applications, fan shall be listed by Underwriters Laboratories (UL/cUL ) for US and Canada. Fan shall bear the AMCA Certified Ratings Seal for Sound and Air Performance. Construction: The fan shall be of bolted and welded construction utilizing corrosion resistant fasteners. The scroll wrapper shall be a minimum." aluminum and the scroll side panels shall be a minimum." aluminum. The entire fan housing shall have continuously welded seams for leakproof operation. A performance cut-off shall be furnished to prevent the recirculation of air in the fan housing. The fan housing shall be field rotatable to any one of eight discharge positions and shall have a minimum -/ inch outlet discharge flange. Bearing support shall be minimum gauge welded steel. Side access inspection ports shall be provided with quick release latches for access to the motor compartment without removing the weather cover. Lifting lugs shall be provided for ease of installation. Unit shall bear an engraved aluminum nameplate. Nameplate shall indicate design CFM, static pressure, and maximum fan RPM. Unit shall be shipped in ISTA Certified Transit Tested Packaging. Coating: Steel fan components shall be Lorenized TM with an electrostatically applied, baked polyester powder coating. Each powder coated component shall be subject to a five stage environmentally friendly wash system, followed by a minimum mil thick baked powder finish. Paint must exceed, hour salt spray under ASTM B7 test method. Wheel: Wheel shall be aluminum centrifugal airfoil blade type. Blades shall be continuously welded to the backplate and deep spun inlet shroud. Wheel hub shall be keyed and securely attached to the fan shaft. Wheel inlet shall overlap an aerodynamic aluminum inlet cone to provide maximum performance and efficiency. Wheel shall be balanced in accordance with AMCA Standard 4-5, Balance Quality and Vibration Levels for Fans. Motor: Motor shall be NEMA Design B with Class B insulation rated for continuous duty and furnished at the specified voltage, phase and enclosure. Bearings: Bearings shall be designed and tested specifically for use in air handling applications. Construction shall be heavy duty regreasable ball or roller type in a cast iron pillowblock housing selected for a minimum L5 life in excess of, hours at maximum cataloged operating speed. Blower Shaft: Blower shaft shall be Type 36 Stainless Steel accurately turned, ground and polished. Shafting shall be sized for a critical speed of at least 5% of maximum RPM. Belts and Drives: Belts shall be oil and heat resistant, static conducting. Drives shall be precision machined cast iron type, keyed and securely attached to the wheel and motor shafts. Drives shall be sized for 5% of the installed motor horsepower. The variable pitch motor drive must be factory set to the specified fan RPM. Product: Fan shall be model CPA-A as manufactured by Loren Cook Company of Springfield, Missouri.
14 Dimensions CPA-A T Z Discharge L Centerline K Shaft Centerline -/" V E F V H D Weather Cover Optional R Q U J A ID U U X B ID P U C OD Y Y G G W M N AA AA CPA-A Dimensions S Dia. Side Size A B C D G H K L M N E F J Class I Class II Class I Class II Class I Class II Class IClass II Class I Class II Class I Class II Class I Class II 9-3/6 3-/8 6-/ /6 3-3/8 9-3/8-3/8 6-/4 3-/4-3/8 8-7/8-5/6 3-/8 -/8 -/4 35-5/6 4-3/4 7-5/8 8 6-/6 3-7/8 9-3/8-3/ / /6 5-/8 -/8 -/8-3/8 5-7/6 6-7/6 9-/8 9-/6 9-9/6 5-5/6 9-3/8-7/8 9-/ /8 8 4-/8 4-9/6 5-/8 -/8 3-/4 3-/ 65-5/8 8-/6-3/6-7/6 4 3-/6 6-3/8 9-3/ / /6 -/8 5-5/6 6-/8 5-/8 5-/4 4-7/6 5-/6 3-3/4 9-/6-/6 -/ /4 7-5/8-3/ /6 35-/ 6-5/6 -/8 6-7/6 7-/4 5-/8 5-/4 5-9/6 6-3/6 4-5/6-5/6 4-3/6 3-/6 4-/4 36-5/6 7-3/6-3/8 3-3/4 35-/6 36-/4 8-3/6 5 -/8 7-5/8 8-/ 8-/8 5-/4 6-3/4 7-3/8 6-/ /6 5-3/8 5-3/8 39-5/6-3/8 3-3/4 38-7/ /6 5 -/8 8-3/4 9-5/8 8-/8 5-/4 7-7/8 8-/ 5 7-3/6 4-5/8 7-7/ /8-7/8 3-7/ /6 5 -/8 9-7/8-7/8 8-/8 5-/ / /4 6-3/6 9-7/6 9-5/8 9-5/8 45-/6-3/4 3-3/8 4-5/6 44-5/8 44-5/ /8 -/6-5/6 8-/8 7-5/6 -/6-5/6-5/8 9-9/6 3-5/6 3-3/8 3-3/8 49-/6 3-3/8 4-3/8 5-7/6 48-7/8 48-7/8 4-7/8 8 4-/8 3-9/6 4-/6 -/8 7-5/6-5/63-/6 3-5/63-3/634-5/6 35-5/8 35-5/8 54-3/8 5-7/8 5-5/6 6-/6 53-5/8 53-5/8 7-3/ /6-3/69-3/6 5-5/6 6-3/ /4 36-/8 37-5/6 38-7/8 38-7/8 59-3/6 8-7/6 6-3/6 7-5/8 58-3/8 58-3/8 9-7/ /6 9-9/6-3/69-3/6 7-5/8 8-9/ /8 39-5/6 4-7/6 4-3/4 4-3/4 -/8 3-7/6 7-3/-3/6 64-/4 64-/4 3-/ /6 3-7/6 4-3/6 9-/4 3-/4 3-7/ /4 44-/6 45-3/6 46-3/4-5/634-/-3/6 -/4 34-5/6 34-5/6 4-3/6 34-/ /6 49-7/6 5-3/8 - -9/6 38-5/6-3/6 - -7/8-38-3/ /6-8-3/6-37-3/ /6 53-5/ /4-3/4 4-3/6 3-3/6 -/4 4-5/ /6 4-3/6 P R V Y Z AA Max. Motor Size Q S T U W X Frame * Ship Wt. Class I Class II Class I Class II Class I Class II Class I Class II Class I Class II Class I Class II Class I Class II Class I Class II 3-9/6 36-3/4 3-7/6 9/6 3/4-5/ /6 8-5/8 9-5/8 5-7/6 5-9/6 9-3/8 -/ T 5T /6 38-3/8 3-7/6 9/6 3/4-5/ /6 8-5/8 9-5/8 6 6-/8 9-3/8-7/6 T 5T /8 4-/4 3-7/6 9/6 3/4-5/8 8 9-/ 4 9-5/8 8-5/8 -/8 6-9/6 6-/6 9-3/8-5/6 T 56T /8 43-5/8 3-7/6 9/6 3/4-5/8 8 -/4 4 -/4 8-5/8 -/4 7-3/6 7-5/8 9-3/8 3-/6 T 56T /8 45-/4 3-3/6 -/6 9/6 3/4-5/8 9 -/4 4-7/8 9-5/8 -/4 7-3/4 8-3/6-3/8 3-/6 5T 56T /8 47-/8 3-3/6 -/6 9/6 3/4-5/ / 9-5/ /6 8-3/6-3/8 3-7/8 5T 56T /4 49-5/6 4-7/6 -/6 9/6 3/4-5/ /6-5/ /8 9-3/8-3/8 3-7/8 5T 56T /6 4-7/6 -/6 9/6 3/4-5/8 -/ -/ /6 -/8 3-/8 9-7/6 -/6-7/8 4-/8 5T 56T /4 58-7/6 4 -/6-5/6 /6 -/8 -/ 3-/ /8 3-5/6 -/ -5/8 3-3/8 4-5/6 5T 56T /4 63-5/6 4 -/6-5/6 /6 -/8 -/ 3-/ /4 3-3/8 4-7/6-7/6 -/6 4-3/8 5-/6 56T T /4 -/ 4-5/6-3/6 /6 -/8 3-/ 3-/ /6 5-/6-5/8 3-5/6 5-5/6 6-5/6 56T T /4 4-5/6-3/6 3/6 -/8 5 5-/ /6 5-3/6 6-5/8 3-3/4 4-9/6 6-3/6 8 56T 36T / -3/4 5-3/6-7/6 3/6 -/ / /6 6-3/6 7-3/6 5-/6 6-/8 7-3/6 9-3/8 34T 36T / 5-3/6 3/6 -/ /6 8-3/ /6 34T /4-5 -7/6-3/6 -/ /6-3/6-8-5/8 - -3/6-36T / 5-7/6 3/6 -/ /8-3/6-3/8 3-3/6 36T All dimensions in inches. Weight in lbs., less motor. For other discharge dimensions, please consult page 7, Compute-A-Fan, an authorized representative or the factory. *Based on open drip proof, single speed. 3
15 CPFB Specifications Centrifugal Vent Set Blower Forward Curved Wheel Belt Drive Loren Cook Company certifies that the CPFB shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication and AMCA Publication 3 and comply with the requirements of the AMCA Certified Ratings Program. Type CPFB is furnished standard with UL 5 listing ( C UL 5) when furnished with factory supplied motor. Description: Fan shall be a single width, single inlet, forward curved, belt driven centrifugal vent set. Certifications: Fan shall be manufactured at an ISO certified facility. Fan shall be listed by Underwriters Laboratories (UL/cUL 5) for US and Canada. Fan shall bear the AMCA Certified Ratings Seal for Sound and Air Performance. Construction: The fan shall be of bolted and welded construction utilizing corrosion resistant fasteners. The scroll wrapper shall be minimum 4 gauge steel and the scroll side panels shall be minimum gauge steel. The entire fan housing shall have continuously welded seams for leakproof operation. The fan housing shall be field rotatable to any one of eight discharge positions and shall have a minimum -/ inch outlet discharge flange. Bearing support shall be minimum gauge welded steel. Side access inspection ports shall be provided with quick release latches for access to the motor compartment without removing the weather cover. Lifting lugs shall be provided for ease of installation. Unit shall bear an engraved aluminum nameplate. Nameplate shall indicate design CFM, static pressure, and maximum fan RPM. Unit shall be shipped in ISTA Certified Transit Tested Packaging. Coating: Steel fan components shall be Lorenized TM with an electrostatically applied, baked polyester powder coating. Each component shall be subject to a five stage environmentally friendly wash system, followed by a minimum mil thick baked powder finish. Paint must exceed, hour salt spray under ASTM B7 test method. Wheel: Wheel shall be centrifugal forward curved type. Wheel hub shall be keyed and securely attached to the fan shaft. Wheel shall utilize an aerodynamic aluminum inlet cone to provide maximum performance and efficiency. Wheel shall be balanced in accordance with AMCA Standard 4-5, Balance Quality and Vibration Levels for Fans. Motor: Motor shall be NEMA Design B with Class B insulation rated for continuous duty and furnished at the specified voltage, phase and enclosure. Blower Shaft: Blower shaft shall be AISI C-45 hot rolled and accurately turned, ground and polished. Shafting shall be sized for a critical speed of at least 5% of maximum RPM. Bearings: Bearings shall be designed and tested specifically for use in air handling applications. Construction shall be heavy duty regreasable ball or roller type in a cast iron pillowblock housing selected for a minimum L5 life in excess of, hours at maximum cataloged operating speed. Belts and Drives: Belts shall be oil and heat resistant, static conducting. Drives shall be precision machined cast iron type, keyed and securely attached to the wheel and motor shafts. Drives shall be sized for 5% of the installed motor horsepower. The variable pitch motor drive must be factory set to the specified fan RPM. Product: Fan shall be model CPFB as manufactured by Loren Cook Company of Springfield, Missouri. 4
16 Dimensions CPFB Shaft Centerline CPFB Dimensions Size A B C D E F G H J K L M 7-9/6-5/6 4-/ 8 -/4-3/4 9-3/8 5-/4-3/4 -/4 3-/8 9-3/6 3-/8 6-3/ /6 3-3/8 9-3/8 6-/4-5/6-7/8 3-/8 5-7/6 6-7/6 9-/ 9-/6 9-9/6 5-5/6 9-3/8 9-/6 4-9/6 4-/8 5-/8 3-3/4 9-/6 -/ -/6 34-3/4 7-5/8-3/8 33-9/6 6-7/8 6-7/6 5-/8 7-3/6 4-5/8 7-/ /8-7/8 4-5/6 5 8-/ /4 6-3/6 9-/4 9-5/8 45-/6-3/4 3-3/8 44-5/8-7/8 5-3/4 8-/8-5/8 9-9/6 3-3/4 3-3/8 49-/6 3-3/8 4-3/8 48-7/8 4-3/ /8 -/8 3-5/6 3-3/6 34-3/4 35-5/8 54-3/8 5-7/8 5-5/6 53-5/8 7-/ /6 Side Size N P Q R S T U V W X Y Z Max. Motor Frame * Ship Wt. 9-3/8 3-3/8 3 3/4 9/6 3/4 -/ 8-/6 4-/6 4-/6 8-5/8 4-/6 45T /6 3 9/6 3/4 -/ 8-/6 4-/6 6-/4 8-5/8 5-/ T /4 37-/8 3 9/6 3/4 -/ 8-/6 4-/6 9-9/6 8-5/8 6-/6 T 5-5/8 43-/8 3 9/6 3/4 -/ 9-/6 4-/6-3/6 9-5/8 7-3/6 5T / /6 9/6 3/4 -/ -9/6 5-/6 7-3/4 -/8 9-9/6 5T 4 5 -/8 58-/4 4-3/6 /6-9/6 5-/6 3-5/6-3/8-9/6 5T /4 4-7/6 /6-9/6 5-/6 33-/6 3-3/8 -/ 56T /6 7-/4 4-7/6 /6 3-9/6 5-/6 36-5/6 4-5/6 3 56T All dimensions in inches. Weight in lbs., less motor. For other discharge dimensions, please consult page 7, Compute-A-Fan, an authorized representative or the factory. *Based on open drip proof, single speed. 5
17 CPFD Specifications Centrifugal Utility Vent Set Blower Forward Curved Wheel Direct Drive Loren Cook Company certifies that the CPFD shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication and AMCA Publication 3 and comply with the requirements of the AMCA Certified Ratings Program. Type CPFD is furnished standard with UL 5 listing ( C UL 5) when furnished with factory supplied motor. Description: Fan shall be a single width, single inlet, forward curved, direct driven centrifugal vent set. Certifications: Fan shall be manufactured at an ISO certified facility. Fan shall be listed by Underwriters Laboratories (UL/cUL 5) for US and Canada. Fan shall bear the AMCA Certified Ratings Seal for Sound and Air Performance. Construction: The fan shall be of bolted and welded construction utilizing corrosion resistant fasteners. The fan housing shall have air tight lock seams and shall be field rotatable to any one of eight discharge positions. Motor mount shall be minimum 4 gauge steel. Unit shall bear an engraved aluminum nameplate. Nameplate shall indicate design CFM and static pressure. Unit shall be shipped in ISTA Certified Transit Tested Packaging. Coating: Steel fan components shall be Lorenized TM with an electrostatically applied, baked polyester powder coating. Each component shall be subject to a five stage environmentally friendly wash system, followed by a minimum mil thick baked powder finish. Paint must exceed, hour salt spray under ASTM B7 test method. Wheel: Wheel shall be centrifugal forward curved type. Wheel hub shall be securely attached to the motor shaft. Wheel shall utilize an aerodynamic inlet cone to provide maximum performance and efficiency. Wheel shall be balanced in accordance with AMCA Standard 4-5, Balance Quality and Vibration Levels for Fans. Motor: Motor shall be heavy duty type with permanently lubricated sealed ball bearings and furnished at the specified voltage, phase and enclosure. Product: Fan shall be model CPFD as manufactured by Loren Cook Company of Springfield, Missouri. CPFD Dimensions Size A B C Min. C Max. D Min. D Max. E F G H J 6 3-/ 8-/ 5-/4 5-3/4 7-5/8 8-/8 7-7/8 4-5/8 5-3/4 -/ -3/4 7 3-/ -/4 8-/8 8-5/8 -/8-5/8 8-3/8 5-3/8 6-/8 -/ -/ /4 -/ -/ -/8 -/8 9-7/8 5-7/8 7-3/4 3-3/4 5-/ -/4 3-5/6 4-5/6 3-3/8 4-3/8-3/8 6-3/8 8 4-/4 3-3/4 7-3/ /8 4-3/8 3-3/8 5-7/ /4 4-/4 Size K L M Min. M Max. N P Q Ship Wt /8-7/8 3-5/8 7/6 7 / /8-7/8 3-5/8 7/6 7 5/ /8 3-3/8 4-5/8 9/6 9 3/ /8 3-3/8 4-5/8 9/6 9 -/ /8 3-3/8 4-5/8 9/6 -/ 6 All dimensions in inches. Dimensions C, D, and M vary with motor frame size. For other discharge dimensions, please consult, Compute-A-Fan, an authorized representative or the factory. 6
SECTION 23 34 13. A. Horsepower: Do not increase or decrease fan motor horsepower without written approval from Engineer.
PART 1 GENERAL SECTION 23 34 13 HVAC FANS 1.01 SUMMARY A. Section Includes: 1. Exhaust fans. 2. Transfer fans. B. Related Documents: 1. Drawings and general provisions of the Contract, including General
More informationUNIVERSITY OF ROCHESTER DESIGN STANDARDS OCTOBER 18, 2013
SECTION 233416 - CENTRIFUGAL HVAC FANS PART 1 GENERAL 1.01 GENERAL REQUIREMENTS A. Fans shall be dynamically balanced and factory-tested and certified in accordance with applicable AMCA test codes. All
More informationTube Axial Roof Upblast Model TAUB with Fabricated Steel Propeller
Tube Axial Roof Upblast Model TAUB with Fabricated Steel Propeller Belt Drive Low and High Pressure October 009 Features Page Header Tube Axial Roof Upblast Fans Greenheck belt drive tube axial upblast
More informationCommercial Gas Furnace Upflow
Commercial Gas Furnace Upflow Model G24-200 80% A.F.U.E. 200,000 Btuh Input Heating Cap. 7.5 or 10 Tons Nominal Add-On Cooling GUK FEATURES Certified by A.G.A./C.G.A. Laboratories. Heavy gauge painted
More informationPump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling
Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling 405_P1 R1/27/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
More informationROOF TOP MOUNTED Air Handler Specification
ROOF TOP MOUNTED Air Handler Specification PART 1: GENERAL (Model RT) Mechanical Specification 1.01 WORK INCLUDED A. Provide complete air handling unit(s) suitable for outdoor installation. Contractor
More informationPump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
More informationUPBLAST & HOODED PROPELLER ROOF VENTILATORS
The Industrial Choice. Model D53 / B53 Model HD53 / HB53 UPBLAST & HOODED ELLER ROOF VENTILATORS Direct Drive & Belt Driven Model D53 / B53 Upblast Exhaust Fans Model HD53 / HB53 Hooded Supply & Exhaust
More informationRecirculating Roof Fans Models ESRMD, ESRMDF and ERD
Recirculating Roof Fans Models ESRMD, ESRMDF and ERD Four-Way Fan Exhaust Supply Mix Recirculate BUILDING VALUE IN AIR. October 2005 Recirculating Roof Fans Exhaust/Supply/Recirculation/Mix Model ESRMD
More informationSPECIFICATIONS FOR BOON EDAM TOMSED MODEL TUT-65TMB
SPECIFICATIONS FOR BOON EDAM TOMSED MODEL TUT-65TMB PRODUCT DESCRIPTION: BOON EDAM TOMSED MODEL TUT-65TMB STAINLESS STEEL BARCODE SCANNING ELECTRONIC REGISTERING TURNSTILE SCOPE OF OPERATION: A. The TUT-65TMB
More informationPump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages
Pump Specifications 2448LSG, 2448LSGX Series Omnivore 2HP Simplex Grinder Packages 2448LSG_P1 R4/2/2012 Copyright 2012 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
More informationModel 362A AURORA. 340A/360A Series SINGLE STAGE END SUCTION PUMPS. www.aurorapump.com
Model 62A MODEL 41A MODEL 44A AURORA 40A/60A Series SINGLE STAGE END PUMPS www.aurorapump.com SINGLE STAGE END PUMPS AURORA 40A/60A Series Single Stage End Suction Pumps Capacities to 4500 G.P.M. (1022
More informationEDD-401. Stationary Louver Dual Drainable Blade. Application and Design. Standard Construction
Application and Design is a weather louver designed to protect air intake and exhaust openings in building exterior walls. Design incorporates a drainable head member and stationary horizontal blades to
More informationHorizontal Jet Pumps 1/3-1-1/2 HP
Horizontal Jet s 1/3-1-1/2 FW01 0909 Supersedes 0409 The CPJ, CPH and EK models feature the famous Flint and Walling Service Plus motor, available in either NEMA J or Uni-frame flange construction. The
More informationSECTION 15732 AIR CONDITIONING UNIT
SECTION 15732 AIR CONDITIONING UNIT PART 1 GENERAL 1.01 SUMMARY A. Section includes: 1. Packaged, split system air conditioning unit No. 1. 1.02 REFERENCES A. Air-Conditioning, Heating, and Refrigeration
More informationBSM MOTOR DRIVEN CENTRIFUGAL PUMPS
PRINCIPLE OF OPERATION A hydraulically and dynamically balanced impeller with raised vane sections discharges liquid as a result of the centrifugal force developed in rotation. The head developed is entirely
More informationINSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS
INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS Frames 143T - 449TZ 5100 North IH 35 Round Rock, Texas 78681 Phone: 800-451-8798 512-255-4141 Fax: 512-244-5512 RECEIVING 1. Check
More informationSECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
More informationVXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6
- B 1 Product Detail Engineering Data... B2 Structural Support... B6 Engineering Specifications... B9 - B 2 Engineering Data REMARK: Do not use for construction. Refer to factory certified dimensions &
More informationTECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP
TECHNICAL BROCHURE B-33GB GB, 7GB, 1GB, 18GB, 2GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP FEATURES Multi-stage Design: Provides steady, quiet, vibration free, operation. Optional Stainless Steel Construction:
More informationVentilation Solutions Kitchens. fantech
Ventilation Solutions Kitchens 2 Kitchens Today s kitchens have become much more than a place for cooking and food preparation. The kitchen is the heart of the home. It s the center of activity for the
More informationCRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ
GRUNDFOS DATA BOOKLET CRN5-5 A-FGJ-G-E-HQQE 3x23/4 5HZ Grundfos Pump 96517184 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn5/96517184/crn-5-5-a-fgj-g-e-hqqe.html
More informationGas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF24-100-400 (10/2011) LF24 Standard
LF Standard Features Horizontal unit heaters are compact in design and easy to install. Steady State Efficiencies of up to 80.%. Ideal for economical commercial heating systems. Shipped completely assembled
More information300 Series PA Pump and Cooler Assemblies
Type 300 Series PA Sizes 300 thru 370 (Page 1 of 9) 300 Series PA Pump and Cooler Assemblies Pump and Cooler Assemblies with Air/Oil Heat Exchanger When compact gear drives require assistance to dissipate
More informationWe will discuss common industrial applications with guides for the proper use of electric motors on these.
INTRODUCTION: Baldor Electric Company has prepared this Specifiers Guide to help you cover all the bases when you are specifying electric motors. It will cover in a generic way most of the subjects which
More informationRPV - RP - RA air handling units
APPLICATIONS Heating, ventilation, cooling >> FACTORIES >> WAREHOUSES >> HALLS >> DISTRIBUTION CENTRES >> COMMERCIAL PREMISES >> PLACES OF WORSHIP RPV - RP - RA air handling units www.reznor.eu RPV - RP
More informationINSTRUCTIONS FOR HOW TO PROPERLY SELECT A FAN OR BLOWER
INSTRUCTIONS FOR HOW TO PROPERLY SELECT A FAN OR BLOWER The instructions that follow are to assist you in completing the information required when making a fan or blower selection. If you need additional
More informationTransformer oil cooler ALFA A02
A02 Transformer oil cooler ALFA Transformer oil cooler ALFA The transformer oil cooler ALFA is used to cool power transformers by means of forced air and oil flow. The oil in the cooler is circulated using
More informationSFI SPECIFICATION 61.1 EFFECTIVE: FEBRUARY 26, 2014
SFI SPECIFICATION 61.1 EFFECTIVE: FEBRUARY 26, 2014 PRODUCT: Turbochargers 1.0 GENERAL INFORMATION 1.1 This SFI Specification establishes uniform test procedures and minimum standards for evaluating and
More informationLU6X-130 Instructions and Parts List (including LU6X Basic) Operating Instructions
LORTONE LU6X-130 Item # 061-092 LU6X Basic Item # 061-090 LU6X-130 Instructions and Parts List (including LU6X Basic) Operating Instructions Introduction The LU6X is one the most versatile pieces of equipment
More informationSurface Technology. Centrifugal Fan GMD
Centrifugal Fan ATEX classed adapted for paint shops Wide assortment broad area of application Service friendly low maintenance costs Headquarters: Centrifugal Fan Centrifugal Fan is a direct driven industrial
More informationFAN & BLOWER CENTRIFUGAL FANS
FAN & BLOWR CNTRIFUGAL FANS INTRODUCTION GNRAL PRODUCT RANG FANS BY FANTCH - INTRACTIV PRODUCT SUIT SLCTION PROGRAM PRFORMANC CONSTRUCTION The Fan & Blower range of centrifugal fans is marketed to the
More informationJames M. Pleasants Company
James M. Pleasants Company SUBMITTAL DATA GAINESVILLE MECHANICAL DECEMBER 20, 2013 PROJECT: GSU: J-183 HUMANITIES LAW BLDG. QUOTE NO:12116 ENGINEER: STEVENS & WILKINSON GASKETED PLATE HEAT EXCHANGER Tag:
More informationBAGGAGE HANDLING SYSTEMS. Trastecnica S.p.A. Handling Baggage Systems Edition 2002 - Rev. 00-1 -
BAGGAGE HANDLING SYSTEMS Trastecnica S.p.A. Handling Baggage Systems Edition 2002 - Rev. 00-1 - TECHNICAL SPECIFICS INDEX Check-in with one conveyor 4 Scales 6 Belt Conveyors 8 Take away 9 Feeder and Belt
More informationTube Type Oil Skimmer Comparison
Process Overview- Tube Type Oil Skimmers Oil flows down the face of the skimmer and into a sludge pan that is plumbed to a barrel. Model BG01 & BG34 or 6V Oil Skimmer 1.0 or 3/4 Diameter Collector Tube
More informationMAC-120HE-01 Air-Cooled Chiller
MAC-120HE-01 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 208/230-1-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-01
More informationChapter 3.5: Fans and Blowers
Part I: Objective type questions and answers Chapter 3.5: Fans and Blowers 1. The parameter used by ASME to define fans, blowers and compressors is a) Fan ration b) Specific ratio c) Blade ratio d) Twist
More informationPAINT BOOTH LIGHTING
PAINT BOOTH LIGHTING PAINT BOOTH LIGHTING Lighting is comprised of many components that need to be considered when selecting the appropriate fixtures and lamps to accomplish a specific task. Selecting
More informationMiami-Dade Qualified Drainable Blade Louvered Penthouse
Application and Design is a gravity intake or exhaust louvered penthouse. Model incorporates high performance horizontal drainable style blades. Meets the performance requirements established by the Florida
More informationARTS AND CRAFTS 10.1.0. 5410 (open) 5412 (doors) H : 84" Tote Tray Storage. Damp Storage. Tote Tray Storage. Notebook Board Storage, Doors
Drawing Board Storage, Open Drawing Board Storage, Doors Drawing Board Storage Notebook Storage, Open 1670 D : 23.25" holds 32 drawing boards 1 shelf, adjustable on 1¼" increments maximum board height
More informationSOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design
SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design Ideal installation for; Offices Branch Offices Schools Computer Aided Classes Government Offices Hotels
More informationIndex 11.1. Page. Pumping Systems...11.2-11.4 Intensifiers...11.5 Gas Boosters...11.6-11.7 High Pressure Generators...11.8-11.9
Pumping Systems, Intensifiers, Gas Boosters and High Pressure Generators High Pressure Equipment Company produces a number of components and systems for general industrial, elevated pressure applications.
More informationCRN32-2-2 A-F-G-E-HQQE 3x400D 50 HZ
GRUNDFOS DATA BOOKLET CRN32-2-2 A-F-G-E-HQQE 3x4D 5 HZ Grundfos Pump 96122352 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn32/96122352/crn-32-2-2-a-f-g-e-hqqe.html
More informationAMD-33 Air Measuring Station with VCD-33 Control Damper
Application and esign Construction Standard Optional Frame Material Galvanized Steel - Frame Material Thickness 16 ga. (1.5mm) 12 ga. (2.7mm) Frame Type 5 in. x 1 in. hat channel - Blade Material Galvanized
More informationInstallation. Centrifugal Roof and Wall Exhausters
This publication contains the installation, operation and maintenance instructions for standard units of the AC- Centrifugal Roof and Wall Exhausters. ACE-D / ACE-B ACW-D / ACW-B / ACW-HP / ACW-XP ACRU-D
More informationAir technology solutions for demanding applications. Product overview. www.elektror.com17
Air technology solutions for demanding applications Product overview www.elektror.com17 Set benchmarks now. Efficient and high-performance solutions from one source. For the past 9 years Elektror airsystems
More informationHORIZONTAL PUMPING SYSTEM
HORIZONTAL PUMPING SYSTEM BORETS U.S. INC. PERFORMANCE TECHNOLOGY INNOVATION Horizontal Pumping System What is HPS? HPS classification, Pumps, Stages, Impellers, Curves/Performance, Components Why use
More informationCHILLED WATER DATA ROOM UNITS
Critical Infrastructure for the World s Leading Data Centers CHILLED WATER DATA ROOM UNITS Downflow Net Sensible Cooling 79 220kW Upflow Net Sensible Cooling 66 206kW A Nortek Company DATA CENTER COOLING
More informationPOWERS Controls No. 4 Pneumatic Damper Actuator
POWERS Controls No. 4 Pneumatic Damper Actuator Technical Instructions Document No. 155-032P25 AP 331-2 Actuator Assembly 331-2929 Typical Actuator Assembly 331-2904 Typical Actuator Assembly 331-3000
More informationSports and High Mast Lighting Poles Phone: (866) 474-7200 Fax: (817) 924-7049
Sports and High Mast Lighting Poles 4 High Mast Lighting Poles General American LitePole offers a raising and lowering system that allows for ease of maintaining the lighting system at ground level. Ideal
More informationPRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS
PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS OVENS MANUFACTURED BY: EARTHSTONE OVENS-6717 SAN FERNANDO RD GLENDALE CA 91201 TELEPHONE: 800-840-4915 818-553-1134 FAX: 818-553-1133
More informationInstallation Manual CLIFC Fan & Coil Variable Speed
Installation Manual CLIFC Fan & Coil Variable Speed General Description GENERAL DESCRIPTION FANS EQUIPMENT Totally Factory assembled within the unit all piping, wiring, and required controls for operation
More informationOwner s Manual EFX. Explosion-Proof Exhaust Fan. This manual covers installations, maintenance, repair and replacement parts. WARNING!
Heaters for the Harshest Environments Owner s Manual ISO 9001 EFX Explosion-Proof Exhaust Fan This manual covers installations, maintenance, repair and replacement parts. WARNING! READ ALL IMPORTANT NOTICES
More informationMorrison Bros. Co. General Product Specifications
Morrison Bros. Co. General Product Specifications Tank Mounted Spillbox The spill containment device is manufactured to contain spills and drips that may occur at the fill point on aboveground storage
More informationOVERALL CONVEYOR WIDTH STEEL ALUMINUM MODEL # PER FT. 10 FT. 5 FT. PER FT. 10 FT. 5 FT. PER FT. 10 FT. 5 FT. PER FT. 10 FT. 5 FT.
Pick Smarter. Pick Better. Pick UNEX. Skatewheel (SW) Skatewheel Gravity Conveyor is ideally suited to convey lightweight packages and where operations require portable or temporary conveyor lines such
More informationA. Section includes air conditioning units, controls and control panels.
SECTION 23 81 23 - COMPUTER-ROOM AIR-CONDITIONERS PART 1 - GENERAL 1.1 SUMMARY A. Section includes air conditioning units, controls and control panels. 1.2 REFERENCES A. Air-Conditioning, Heating, and
More informationMICRO HYDRO POWER GENERATING EQUIPMENT
MICRO HYDRO POWER GENERATING EQUIPMENT TOSHIBA TOSHIBA ENGINEERING In general, specifications of hydroelectric power system vary depending upon the installation location. The hydro turbine and generator
More informationMODEL IX -WAC/HP AIR CONDITIONERS & HEAT PUMPS FOR HIGHLY CORROSIVE & HAZARDOUS AREAS
1.5, 2, 2.5, 3, 3.5, 4, 5 & 6 Ton Industrial Grade Wall Mounted Air Conditioners & Heat Pumps Unit Application Bebco Model IX-WAC/HP Industrial Grade Air Conditioners & Heat Pumps are designed as a total
More informationSECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT
SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION A. The Work specified in this Section consists of designing, furnishing and installing factory-assembled
More informationBERTHOLD ELECTRIC GENERATOR CONNECTION CABINET
BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET Berthold Electric Company s Generator Connection Cabinet provides a quick and convenient station to connect a portable generator to a facility s main service
More informationEurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump
Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pumps Eurovacuum Company is offering its various products to meet industrial vacuum
More informationRoller Chain Coupling
Roller Chain Coupling Features 1. Simple structure A roller chain coupling consists of one duplex roller chain and two sprockets for a simplex chain. Handling is very simple as both the shafts (driving
More informationSECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS
SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating
More informationType 1, 3, & 3R Enclosures
Junction oxes Type 1 Screw over....................................................................... 50-53 Junction oxes Type 1 Hinge over........................................................................
More informationSTB Series Enclosures
STB Series Enclosures Features/Applications: The STB series of sheet steel enclosures are designed to meet the requirement for distribution and lighting junction boxes. Available in 14 sizes with standard
More informationSECTION 6. Glass Storefront Doors:
SECTION 6 Glass Storefront Doors: Table of Contents 3070 Storefront Door System Description & Dimensions 6070 Storefront Door System Description & Dimensions Door Leaf Detail Optional 10 Bottom Rail Detail
More informationCooking at the Speed of light!
Cooking at the Infrared Cooking & Colouring Infrabaker is a modular infrared continuous cooking system developed by Infrabaker International. The machine is designed to cook and/or put colour on a wide
More informationCity of San Diego, CWP Guidelines
PART 1 -- GENERAL SECTION 08520-1.1 WORK OF THIS SECTION City of San Diego, CWP Guidelines A. The WORK of this Section includes providing aluminum windows with frames, bracing, glazing attachments, screens,
More informationLow Voltage Transformers Sealed, General Purpose, Dry Type
Low Voltage Transformers Sealed, General Purpose, Dry Type Catalog 7400CT9601R4/08 08 Class 7400 CONTENTS Description..............................................Page Introduction.................................................
More information9300BC SERIES Light Commercial Door Closer
Light Commercial Door Closer general information The 9300BC is a durable, economically priced door closer designed for commercial exterior and interior doors such as storefront and industrial applications.
More informationAIR CONDITIONING PRODUCTS COMPANY
Quality Products Fixed Louvers AIR CONDITIONING PRODUCTS COMPANY all Shutter Backdraft Damper Ceiling Shutter Motorized Damper Fixed Louver Ga le Shutter Drainable Louver Supply Damper Fiberglass Shutter
More informationJIC CONTINUOUS HINGE BOXES
JIC CONTINUOUS HINGE BOXES Austin JIC Continuous Hinge (JH) boxes are Underwriters Laboratories Listed and are designed for use as electrical junction boxes, terminal wiring boxes, and instruments housing.
More informationAPCO SLOW CLOSING AIR/VACUUM VALVES
BULLETIN 1 JULY 01 APCO SLOW CLOSING AIR/VACUUM VALVES Series 1900 APCO Slow Closing Air/Vacuum s Maximum Air Flow Velocity in Good Pipeline Design The Air/Vacuum operates in the normal fashion allowing
More informationFan Dia. Motor Amps Connections Approx. 115 V 10 O TD 15 O TD H W D CFM (Quantity) 115 V 230 V Inlet Suction Drain Ship. Wt. Lbs.
COMPACT UNIT FOR CEILING OR WALL MOUNT Fan Dia. Motor Amps Connections Approx. 115 V 10 O TD 15 O TD H W D CFM (Quantity) 115 V 230 V Inlet Suction Drain. MJ-40 400 600 7 13 5/8 8 125 5 1/4" 0.65 0.35
More informationPipe Cutting and Beveling Clamshells
Pipe Cutting and Beveling Clamshells Who We Are One Company, Total Support, Complete Solutions For more than a century, Hydratight has provided world-class bolted joint solutions and continues to set international
More informationMONITOR SECTION INDEX
MONITOR SECTION INDEX Daspit Tool... E2 Daspit Tool - Truck Mount... E3 Daspit Tool - Throw Down Model... E4 Alpha MA-HV4-4 Aluminum Tiller Bar Monitor... E5 Alpha-E Tiller Bar Montior - 3... E6 SharpShooter
More informationECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
More informationCFM @.0 SP H/M/L AFLR-12 12 3.033 1565/1464/1309 60 1836/1469/1175 24/22/20 115 AFLR-20 20 3 1/8 1468/1209/1063 60 7562/6050/4840 34/31/28 115
Air Circulators High Velocity Floor Fans Circulate Large Volumes of Air Product Specifications Size Spd HP HZ CFM/WATT @.0 SP AFLR-12 12 3.033 1565/1464/1309 60 1836/1469/1175 24/22/20 115 AFLR-20 20 3
More informationCE6500 Energy Recovery Ventilator
ADVANCED COMMERCIAL Energy Recovery Ventilator PRODUCT SPECIFICATIONS & TECHNICAL DATA Features NOMINAL CAPACITY 5500-7000 CFM CASING Double-wall cabinet White exterior paint, -gauge galvanized steel -gauge
More informationNational System of Garage Ventilation s Engineering Guide
National System of Garage Ventilation s Engineering Guide In designing a fume removal system, it is extremely important to determine the following: 1. Type of apparatus to be exhausted (i.e. gasoline,
More informationN E R / E R T H R E E P H A S E ELECTRIC C H A I N H O I S T S
N E R / E R T H R E E P H A S E ELECTRIC C H A I N H O I S T S W o r k i n g H a r d e r F o r Yo u In 1876, Edwin Harrington dramatically improved the self-sustaining hoist by introducing the worm-gear
More informationSECTION 233000 HVAC AIR DISTRIBUTION
1320 / Talent Community Center 233000-1 HVAC AIR DISTRIBUTION SECTION 233000 HVAC AIR DISTRIBUTION PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Ductwork. 2. Ductwork accessories. 3. Fans. 4. Air
More informationFAIRBANKS NIJHUIS FIRE PUMPS. www.fairbanksnijhuis.com
FAIRBANKS NIJHUIS FIRE PUMPS www.fairbanksnijhuis.com FAIRBANKS NIJHUIS Long established as a leading fire pump manufacturer, Fairbanks Nijhuis offers a broad range of horizontal and vertical split case,
More informationsecurity products metric sizes Redefine your comfort zone. www.titus-hvac.com
metric sizes secure lethal objects monitoring areas suicide deterrent Redefine your comfort zone. www.titus-hvac.com humid areas prevents corrosion minimum security medium security maximum security Table
More informationModel RC Armature-Slot- Insulation Folder
Model RC Armature-Slot- Insulation Folder 21 Model RC will handle insulation material up to 8 wide between its guides. Creasing rollers are adjustable sideways to make troughs up to 6 wide. A fixed ruler-guide
More informationJohnson Air-Rotation Systems
AR Series TM Johnson Air-Rotation Systems Solution TM D Series TM FF Series TM 80/20 PR Series TM Johnson Air-Rotation systems announces a major addition to its product line, completing its line of high
More informationMechanical Rooftop Custom Capabilities
Mechanical Rooftop Custom Capabilities Mechanical Construction Capabilities Price manufactures a wide range of custom gas heat and DX cooled units to meet your new construction and retrofit needs. In addition
More informationStandard offering (pumps)
MDM PUMPS LTD Spring Lane Malvern, Worcs. England. WR14 1BP This outlines what we typically supply. Tel: +44 (0)1684 892678 Fax: +44 (0)1684 892841 E-mail: Website: Standard offering (pumps) info@mdmpumps.co.uk
More informationDirect Gas Fired [Make-Up Air / Displacement Ventilation / Space Heating] System
Section 15622 AA-Series (rev. 04/16/15) Direct Gas Fired [Make-Up Air / Displacement Ventilation / Space Heating] System Note: Optional items and/or items requiring a choice, are shown between brackets
More informationHeavy-Duty Lube and Fuel Truck Sales Tool
Heavy-Duty Lube and Fuel Truck Sales Tool Contact: Adrian Britt or Mike Kelley @ (678) 639-0099 33,000 lb. Lube/Fuel Truck Contact: Adrian Britt or Mike Kelley @ (678) 639-0099 Example Specification
More informationManual piston sampler...m 11
SAMPLING Manual piston sampler...m 11 Screw sampler...prec 22...PREC 100 Slide sampler...pr 55 Rotative screw sampler...prv Piston sampler...p 11 Sampler on belt conveyor...pba Rotating cup sampler...pgr
More informationPreformed Metal Roofing and Siding
Page -1-1. GENERAL 1.1. Description This specification along with the drawings covers the furnishing of all material, products, equipment, accessories, tools, services, transportation, labor and supervision
More informationAccessories for GF and RA machines
Orbital cutting & beveling machines for high-purity process piping www.orbitalum.com Accessories for GF and RA machines A brand of ITW Orbital Cutting & Welding 23 www.orbitalum.com Orbital cutting & beveling
More informationUniquely designed and engineered specifically for the pulp and paper industry.
Universal SPU2 Series Uniquely designed and engineered specifically for the pulp and paper industry. For more than half a century, Waukesha Cherry-Burrell has been a leader in the design, manufacturing
More information26 3213.13 Diesel Engine Driven Generators Page 1 of 6
Last Update: December 8, 2014 A. Description of System Consultant s Handbook Page 1 of 6 1. Provide a diesel engine driven electric generating unit, factory assembled, tested and certified to operate at
More informationAMPSEAL* Automotive Plug Connector and Header Assembly
AMPSEAL* Automotive Plug Connector and Header Assembly Application Specification 24 SEP 97 Rev E All dimensions are given in millimeters unless otherwise specified. All dimensional tolerances are +0.2
More informationTOP RUNNING SINGLE GIRDER BRIDGE CRANE
SECTION 14630 TOP RUNNING SINGLE GIRDER BRIDGE CRANE 1.01 SUMMARY PART 1- GENERAL A. The work required under this section shall include the designing, manufacturing, shipping, installing and field testing
More informationVentilation Solutions Radon Mitigation
Ventilation Solutions Radon Mitigation 2 Radon Mitigation Radon is a health hazard with a simple solution Radon is everywhere! You can t see radon and you can t smell it or taste it, but it may be a problem
More informationFan Applications. Major Considerations Defined. Fan Application. Major Application Considerations. A. Fan Types FA/126-06
Fan Application FA/126-06 A technical bulletin for engineers, contractors and students in the air movement and control industry. Fan Applications There are many different types of fans and many applications
More informationCT-02 CABLE TRAY SYSTEMS
CT-02 CABLE TRAY SYSTEMS SYSTEMS THAT MAKE SENSE Introduction B-Line Systems was formed in 96 and has over 30 years experience manufacturing cable tray systems in which it has grown to become the industry
More information