1 Steel Building Systems Steelway Product Specifications 1.0 Table of Contents 2.0 General References System Description Design Criteria Source Quality Control Drawings Certification Protection Performance Testing Standing Seam Roof System Through Fastened Roof and Wall Systems Architectural/Self-Framing Wall Systems Products Materials: Primary Structural: Secondary Structural: Cladding Systems: Roof Cladding Systems Exterior: Roof Trim System: Roof Cladding Systems Interior (liners): Roof Stand-off Systems: Wall Cladding Systems - Exterior: Wall Trim System: Wall Cladding Systems Interior (Liners): Wall Stand-off Systems: Fabrication Shop Painting Execution Erection Wall Cladding Roof Cladding Liner Sheets Steelway Standard Material Specifications Panels Fasteners Trim Purlins, Girts & Jambs Structural Structural Bolts Anchor Rods Standard Steelway Anchor Rod Sizes 12 Rev: Oct 30/07 Page 1 of 12

2 2.0 General 2.1 References SAE J429 Grade 8.2, Low Carbon Martensite Steel, Quenched and Tempered. ASTM A529/A529M, High Strength Carbon, Manganese Steel of Structural Quality. ASTM A1011/A1011M, Steel, Sheet and Strip, Hot-Rolled, Carbon, Structural, High-Strength Low Alloy and High-Strength Low-Alloy with Improved Formability. ASTM A653/A653M, Steel Sheet, Zinc-Coated (Galvanized). ASTM A307, latest edition, Specification for Carbon Steel Bolts and Studs, 60,000 psi tensile. ASTM 325M, latest edition, Specification for High-Strength Bolts for Structural Steel Joints Metric. ASTM A792/A792M, Specification for Steel Sheet, Zinc/Aluminum-Coated (Galvalume) by the HotDip Process, Structural (Physical Quality). CSSBI 30 M Standard for Steel Building Systems. CSSBI B8-95 Building Incorporating Steel Building Systems: Responsibility of Parties Involved. CSSBI Bulletin No. B15-93 Snow, Wind and Earthquake Design Criteria for Steel Building Systems. CSSBI Sheet Steel Facts #3: Care and Maintenance of Prefinished Sheet Steel Building Products, June G40.20/G40.21 latest edition, Structural Quality Steels. ASTM A992/A992M, Standard Specification for Steel Structural Shapes for use in Building Framing. S136, latest edition, North American Specification for the Design of Cold- Formed Steel Structural Members. S16, latest edition, Limit States Design of Steel. CISC/CPMA I-73a, A Quick-Drying One-Coat Paint for use on Structural Steel. W47.1, latest edition, Certification of Companies for Fusion Welding of Steel Structures. W59, latest edition, Welded Steel Construction (Metal Arc Welding). 2.2 System Description Type: rigid frame or beam and column with vertically braced bays as indicated. Roof Slope: minimum 1:48 or as indicated on drawings. Wall System: through fastened or concealed fastener, single skin. Roof System: fully thermally broken standing seam, concealed fastener, single skin or through fastened roof, single skin. Stand-Off System: notched zee, hat and chair or metal capped thermal block. Liner System: through fastened, single skin. 2.3 Design Criteria Design steel building system to withstand live loads and dead loads including ceilings, mechanical and electrical systems, as indicated. Design building walls and roof to allow for thermal movement of component materials caused by ambient temperature range of -40 deg C (-40 deg F) to +40 deg C (104 deg F) without buckling, failure of joint seals, undue stress on fasteners or other detrimental effects. Rev: Oct 30/07 Page 2 of 12

3 Building shall be weathertight. Design building enclosed elements to accommodate, by means of expansion joints and clips any movement in element itself and between element and building structure caused by structural movements without permanent distortion, breakage of seals or water penetration. Refer to drawings and A660 Certificate of Design and Manufacturing Conformance for additional design criteria. 2.4 Source Quality Control Provide a certificate that steel building system manufacturer is certified to CSA-A660, latest edition. 2.5 Drawings Submit erection drawings bearing stamp and signature of professional engineer registered in the province/state in which the building is to be erected. Submit the following documents in accordance with the CSSBI 30 M paragraph 13; erection drawings showing foundation loads, anchor rod setting details, part numbers, connections and assembly details. Indicate plans and grid lines, structural members and connection details, bearing and anchorage details, roof cladding, wall cladding, framed openings, camber (as required), loads and reaction forces, fasteners and field welds (as required), sealant locations and details. Indicate shop and erection details including cuts, copes, connections, holes, threaded fasteners, rivets and welds. Indicate on erection drawings related provisions required for mechanical, electrical and other work, when such information can be supplied to building manufacturer at time of initial order. 2.6 Certification Submit A660 Certificate of Design and Manufacturing Conformance stating design criteria used and loads assumed in design. Certificate shall be stamped and signed by a professional engineer registered in the province/state in which the building is to be erected. Provide documentation to show steel building systems manufacturer is certified under W47.1, Division 1 or 2.1, for welded fabrication. 2.7 Protection Protect pre-finished steel sheet during fabrication, transportation, site storage and installation in accordance with CSSBI Bulletin No. 9. Handle and protect galvalume materials from damage to zinc/aluminum coating. During storage, separate surfaces of galvalume materials to permit free circulation of air. Provide protection from weather to all primary and secondary steel components if stored on site by means of properly secured tarps. Components should be prevented from prolonged contact to the ground by means of adequately spaced blocking. Avoid incurring undue stresses on building components from lifting or twisting during building erection. Rev: Oct 30/07 Page 3 of 12

4 2.8 Performance Testing Standing Seam Roof System Underwriters Laboratories Inc. U.L. Class 90 rating Corps of Engineers Uplift Test ASTM E1592, 156 psf mean ultimate load obtained Factory Mutual Research Corporation FM4477 Uplift Test 1-60 and 1-90 rating ASTM Air and Water Penetration Testing ASTM E1680 Air Infiltration ASTM E1645 Water Leakage Through Fastened Roof and Wall Systems Underwriters Laboratories Inc. U.L. Class 90 rating Diaphragm tests ASTM E Architectural/Self-Framing Wall Systems Diaphragm testing ASTM E455 Compression testing ASTM E72-98 Rev: Oct 30/07 Page 4 of 12

5 3.0 Products 3.1 Materials: Primary Structural: Structural steel: to G40.20/G40.21, ASTM A992/A992M, 50 ksi (340 MPa) minimum yield, shop primed with 30 day primer. o Hot rolled sections, 50 ksi (340 MPa) minimum yield. o Bar & Plate for welded sections, Flange & Webs, 50 ksi (340 MPa) minimum yield. Surface preparation to SSPC-SP3. Welded Materials: to W59. Shop Primer Paint: Single Coat Grey Oxide Primer to CISC/CPMA Standard 1-73a, 1.5 to 2 mils film thickness. Bolts: ASTM A325M (ASTM A490M when required) complete with nuts and washer. Anchor Rods: G40.21, ASTM A992/A992M, 50 ksi (340 MPa) minimum yield Secondary Structural: Structural steel: o Purlins & Girts: minimum 16 gauge (0.060 in/1.52 mm), Hot Rolled Sheet Steel conforms to G40.21, ASTM A1011/A1011M, 50 ksi (340 MPa) minimum yield. Grey Powder Coat Primer (epoxy/ polyester hybrid), 1.5 mils film thickness. o Opening Framing: minimum 16 gauge (0.060 in/1.52 mm), Hot Rolled Sheet Steel conforms to G40.21, ASTM A1011/A1011M, 50 ksi (340 MPa) minimum yield. Grey Powder Coat Primer (epoxy/ polyester hybrid), 1.5 mils film thickness. o Purlin Stabilizers: Minimum 18 gauge (0.048 in/1.22 mm) zee section stabilizers factory cut and pre-packaged shall be provided between purlins to stabilize top and bottom flanges on all roofs with standing seam panels and clips. Number of rows per bay to be determined by design. Hot Rolled Sheet Steel conforms to ASTM A653/A653M, galvanized G60 33 ksi (230 MPa) minimum yield. o Shop Primer Paint: Single Coat Grey Oxide Primer to CISC/CPMA Standard 1-73a, 1.5 to 2 mils film thickness. Grey Powder Coat Primer (epoxy/ polyester hybrid), 1.5 mils film thickness. Bracing Systems: o Flange brace: to ASTM A653, galvanized G90, 50 ksi (340 MPa) minimum yield. o Rod: to G40.21, ASTM A992/A992M, 50 ksi (340 MPa) minimum yield, shop primed with 30 day primer. o Cable: Galvanized strand to ASTM A475 Class A coating (CSA G12). Design strength based on manufacturer s published breaking strengths. o Eye bolts: Forged, 1030 carbon steel, hot galvanized. Design strengths based on manufacturers published breaking strengths. o Bolts: to ASTM 307 or SAE J429 Grade Cladding Systems: Pre-finished System for Steel Sheet Exposed to Exterior: Aluminum-zinc coated material with factory applied paint system: o Insulation and Tape: as recommended by steel building systems manufacturer. Rev: Oct 30/07 Page 5 of 12

6 o o o Insulation Adhesive: purpose made for insulation type and steel liner sheet, incombustible after initial set. Vapor Barrier and Sealing Tape: as recommended by insulation supplier. Sealant: as recommended by manufacturer Roof Cladding Systems Exterior: Sheet Steel: 26 gauge (0.018 in/0.46 mm) minimum standard factory preformed steel sheet aluminum-zinc coated to match existing, pre-finished profile. Include closures, gaskets, caulking, flashing and fasteners to effect weathertight insulation. Steel Sheet, Aluminum-Zinc Coated: to ASTM A792 structural quality Grade 33 or Grade 50 with AZM165 Galvalume Plus coating, regular spangle surface, passivated for unpainted finish and AZM150 unpassivated for paint finish. Paint System: o exterior Series 8000 o interior washcoat (minimum) Colour: choose from manufacturers Standard Series Screws: corrosion resistant purpose made, head colour to match cladding. Through Fastened: 26 gauge (0.018 in/0.46 mm) panel minimum, 1.5 in (38 mm) deep profile, 36 in (914 mm) coverage. Major corrugations at 12 in (305 mm) on centre, shallow corrugations in panel flat. Structural bearing side edge for stable sidelap. Standing Seam: 24 gauge (0.024 in/0.61 mm) panel minimum, 3 in (76 mm) raised panel seams, 24 in (610 mm) coverage. Major corrugations at 24 in (610 mm) on centre, shallow corrugations in panel flat. Factory applied mastic for sidelap, pre-punched and factory notched. Standing Seam Panel Thermal Clips and Related Panel Fasteners: extra heavy duty, 20 gauge (0.036 in/0.91 mm), corrosion resistant, purpose made clips with movable tabs. Spacing of clips and fasteners to be manufacturer's design to suit the loads indicated. Floating clips to allow the roof a 3.5 in (89 mm) range of thermal movement (1 in (44 mm) of expansion and 1 in (44 mm) of contraction). Thermal Block Spacers: continuous 1 in (25 mm) thick, extruded polystyrene meeting CAN/CGSB M87, Type 4, 210 KPa compressive strength Roof Trim System: Accessories to Roof Cladding: brake or bend to shape, of material and finish to match roof cladding or wall cladding where applicable, comprising cap flashing, drip flashing, coping and closures for corners, soffit and fascia. Ridge Cap: brake or bend to shape, 26 ga (0.018in/0.46mm) minimum, colour to suit roof cladding or as specified. Gutters: 26 gauge (0.018 in/0.46 mm) factory brake formed, material and finish to match roof or wall cladding. Include brackets, fasteners, end caps and closures as required Roof Cladding Systems Interior (liners): Sheet Steel: 28 gauge (0.015 in/0.38 mm) minimum standard factory preformed steel sheet aluminum-zinc coated to match existing, pre-finished profile. Include closures, gaskets, caulking, flashing and washered fastener when specified. Steel Sheet, Aluminum-Zinc Coated: to ASTM A792 structural quality Grade 33 or Grade 50 with AZM165 Galvalume Plus coating, regular spangle surface, passivated for unpainted finish and AZM150 unpassivated for paint finish. Rev: Oct 30/07 Page 6 of 12

7 Through Fastened Panel: 28 gauge (0.015 in/0.38 mm) panel minimum, 1.5 in (38 mm) deep profile, 36 in (914 mm) coverage. Major corrugations at 12 in (305 mm) on centre, shallow corrugations in panel flat Roof Stand-off Systems: Notched Zee: 16 gauge ( in/1.44 mm) minimum, factory notched zee to suit liner profile. Depth to suit insulation value required. Hot Rolled Sheet Steel conforms to G40.21, ASTM A1011/A1011M, 50 ksi (340 MPa) minimum yield, galvanized to G60 (minimum). Include required fasteners. Hat and Chair: 16 gauge (0.060 in/1.52 mm) minimum, brake formed to suit liner profile. Depth to suit insulation value required. Hot Rolled Sheet Steel conforms to G40.21, ASTM A1011/A1011M, 50 ksi (340 MPa) minimum yield. Grey Powder Coat Primer (epoxy/ polyester hybrid), 1.5 mils film thickness. Include required fasteners Wall Cladding Systems - Exterior: Sheet Steel: factory preformed steel sheet, 26 gauge (0.018 in/0.46 mm) minimum base metal thickness aluminum-zinc coated pre-finished to match existing profile. Include closures, gaskets, caulking, flashing and fasteners to effect weathertight installation. Steel Sheet, Aluminum-Zinc Coated: to ASTM A792 structural quality Grade 33 or Grade 50 with AZM165 Galvalume Plus coating, regular spangle surface, passivated for unpainted finish and AZM150 unpassivated for paint finish. Paint System: Exterior Series 8000 interior washcoat (minimum) Colour: choose from manufacturers Standard Series Screws: corrosion resistant purpose made, head colour to match cladding. Through Fastened Panel: 26 gauge (0.018 in/0.46 mm) panel minimum, 1.5 in (38 mm) deep profile (standard or reversible face (wide rib out)), 36 in (914 mm) coverage. Major corrugations at 12 in (305 mm) on centre, shallow corrugations in panel flat. Structural bearing side edge for stable sidelap Concealed Fastener Panel: 24 gauge (0.024 in/0.61 mm) panel minimum, 3 in (76 mm) deep profile, flat face or sculptured, 16 in (406 mm) coverage, embossed finish (optional) Wall Trim System: Exterior Corners: of material to match finish and profile of adjacent cladding material, shop cut and brake formed to correct angle. Accessories to Exterior Wall Cladding: brake or bend shape, of material and finish to match wall cladding, consisting of cap flashings, drip flashings, corner flashings, header, jamb and sill trims. Closures to be foam (grey only) or metal (colour and material to match wall cladding). All trim material to be pre-finished 26 gauge (0.018 in/0.46 mm) minimum. Foam closures: Cross-linked polyethylene with UV stabilizers. Field applied tape sealant as required. Downspouts: 26 gauge (0.018 in/0.46 mm) factory brake formed, material and finish to match wall cladding. 28 gauge (0.015 in/0.38 mm) minimum, roll formed, aluminum alloy #3105-H14 (Dark Brown QC8229, Bone White QC8273) Wall Cladding Systems Interior (Liners): Sheet Steel: 28 gauge (0.015 in/0.38 mm) minimum standard factory preformed steel sheet aluminum-zinc coated to match existing, pre-finished Rev: Oct 30/07 Page 7 of 12

8 profile. Include closures, gaskets, caulking, flashing and washered fastener when specified. Steel Sheet, Aluminum-Zinc Coated: to ASTM A792 structural quality Grade 33 or Grade 50 with AZM165 Galvalume Plus coating, regular spangle surface, passivated for unpainted finish and AZM150 unpassivated for paint finish. Through Fastened: 28 gauge (0.015 in/0.38 mm) panel minimum, 1.5 in (38 mm) deep profile, 36 in (914 mm) coverage. Major corrugations at 12 in (305 mm) on centre, shallow corrugations in panel flat Wall Stand-off Systems: Notched Zee: 18 gauge (0.048 in/1.21 mm) minimum, factory notched zee to suit liner profile. Depth to suit insulation value required. Hot Rolled Sheet Steel conforms to ASTM A653/A653M, 33 ksi (230 MPa) minimum yield, galvanized to G60 (minimum). Include required fasteners. Metal Capped Thermal Block: 18 gauge (0.048 in/1.21 mm) minimum factory applied metal cap to ASTM-A 446 grade A, galvanized steel ASTM-A 525M Z275. Close-cell polystyrene, compressive strength 30 psi (207 kpa). Thermal resistance to ASTM C518-70, RSI Include required fasteners. 3.2 Fabrication Fabricate structural members in accordance with shop drawings and to S16. Tolerance not to exceed those specified in CSSBI 30 M. Provides holes for attachment of other work, as indicated. 3.3 Shop Painting Clean, prepare surfaces and shop prime structural steel to S16 except where members are zinc coated or zinc-aluminum alloy coated or to be encased in concrete. Rev: Oct 30/07 Page 8 of 12

9 4.0 Execution 4.1 Erection Do work in accordance with CSSBI Standard for Steel Building Systems 30 M except where specified otherwise. Erect structural frame in accordance with erection drawings and to S16. Erection tolerances not to exceed those specified in CSSBI 30 M. Obtain written permission of steel building manufacturer prior to field cutting or altering of structural members. Touch up with shop primer bolts, rivets, welds, and burned or scratched surfaces where exposed to exterior at completion of erection. 4.2 Wall Cladding Install wall cladding assemblies ensuring a complete installation. Secure to structural wall supports. 4.3 Roof Cladding Erector to ensure they are completely familiar with products prior to installation. All related erections drawings, details and manuals must be reviewed prior to commencing work. Ensure building is square and plumb before cladding installation. Secure sheets to structural purlins as indicated on erection drawings and details. Terminate sheet ends over structural supports. Secure and continuously seal side and end laps. Apply all caulking and closures as per erection details and manufacturer s supplied erection manuals. Install roof assemblies ensuring a complete and watertight installation. 4.4 Liner Sheets Install all necessary closures, gaskets, caulking sealants and flashing as recommended by steel building systems manufacturer, when specified. Rev: Oct 30/07 Page 9 of 12

10 5.0 Steelway Standard Material Specifications 5.1 Panels Roll to Loc (RTL-24) Use: Roof Gauge: 24 (0.024 in/0.61 mm) Flat Girth: Coverage Width: 24 Yield: 50 ksi Plain: AZM165 Galvalume Plus 8,000 Series AZM150 Bone White Paint: QC8273 Storm Seal Use: Roof/Wall Gauge: 24 (0.024 in/0.61 mm) Flat Girth: Coverage Width: 36 Yield: 33 ksi Plain: AZM165 Galvalume Plus 8,000 Series AZM150Bone White Paint: QC8273 Storm Seal Use: Roof/Wall Gauge: 26 (0.018 in/0.46 mm) Flat Girth: Coverage Width: 36 Yield: 33 ksi Plain: AZM165 Galvalume Plus 8,000 Series AZM150 Galvalume Paint: Bone White Dark Brown Stone Grey Slate Blue Tan Melchers Green Medium Green White White QC8273 QC8229 QC8305 QC8260 QC8315 QC8307 QC8329 QC8317 All Steel Standard Storm Seal Use: Roof/Wall Gauge: 28 (0.015 in/0.38 mm) Flat Girth: Coverage Width: 36 Yield: 33 ksi Plain: AZM165 Galvalume Plus 8,000 Series AZM150 Galvalume Paint: Bone White QC8273 Wood/Steel Standard Note: As wall cladding, Stormseal profile panels can be installed with either Narrow Rib Out or Wide Rib Out orientation (must be specified in order) Tech Loc 16 Use: Wall Gauge: 24 (0.024 in/0.61 mm) Flat Girth: Rev: Oct 30/07 Page 10 of 12

11 Coverage Width: 16 Yield: 37 ksi 8,000 Series AZM150 Galvalume Paint: Bone White QC Fasteners Exposed fasteners are to match adjacent panel colours with the exception being galvalume panels which use Bone White fasteners. Exposed fasteners are to be nylon head to resist corrosion. Washered fasteners are to be used on outer roofing, non-washered fasteners are to be used on outer wall siding. Non-washered fasteners are to be used on liner cladding unless specified otherwise. 5.3 Trim Tech Loc 16: 18 gauge (0.048 in/1.21 mm) trims at base, eave and inlets at wall openings, for self framing buildings only. Available in QC8273 Bone White only. Storm Seal: 26 gauge (0.018 in/0.46 mm) standard trims in the same colour as the adjacent wall panels. Fascia & Gutter: 26 gauge (0.018 in/0.46 mm) standard available in the same colour as the wall panels. Rev: Oct 30/07 Page 11 of 12

12 Downspouts: Available in QC8273 Bone White or QC8229 Dark Brown, 10' lengths. Downspout Elbows: Available in QC8273 Bone White or QC8229 Dark Brown, 135 only. 5.4 Purlins, Girts & Jambs 8 in/203 mm Cold Formed Cee & Zee Sections available in 10 ga (0.135 in/3.4 mm), 12 ga (0.105 in/2.67 mm), 13 ga (0.090 in/2.29 mm), 14 ga (0.075 in/1.91 mm) & 16 ga (0.060 in/1.52 mm). 10 in/254 mm Cold Formed Cee & Zee Sections available in 10 ga (0.135 in/3.4 mm), 12 ga (0.105 in/2.67 mm), 13 ga (0.090 in/2.29 mm), 14 ga (0.075 in/1.91 mm) & 16 ga (0.060 in/1.52 mm). 12 in/305 mm Cold Formed Cee & Zee Sections available in 10 ga (0.135 in/3.4 mm), 12 ga (0.105 in/2.67 mm), 13 ga (0.090 in/2.29 mm), 14 ga (0.075 in/1.91 mm). Hot Rolled Sheet Steel conforms to G40.21, ASTM A1011/A1011M, 50 ksi (340 MPa) minimum yield. Grey Powder Coat Primer (epoxy/ polyester hybrid), 1.5 mils film thickness. 5.5 Structural Hot rolled sections, 50 ksi (340 MPa) minimum yield. Bar & Plate for welded sections, Flange & Webs, 50 ksi (340 MPa) minimum yield. Surface preparation to SSPC-SP3. Single Coat Grey Oxide Primer to CISC/CPMA Standard 1-73a, 1.5 to 2 mils film thickness. 5.6 Structural Bolts Plate to Plate Connection, ASTM A325 or ASTM A490 as design requires. Secondary Structural Bolts, SAE J429 Grade 8.2, 150 ksi (1020 MPa) specified minimum tensile strength 5.7 Anchor Rods Must be ordered separately; length by foundation designer from Steelway s standard range. G40-21 ASTM A992/A992M, 50 ksi (340 MPa) minimum yield. Builder to notify foundation designer of length of anchor rods available if purchasing them from Steelway Standard Steelway Anchor Rod Sizes 3/4" Diameter x 18" Long (15" Embedment & 3" Hook) 7/8" Diameter x 21" Long (18" Embedment & 3" Hook) 1" Diameter x 24" Long (20" Embedment & 4" Hook) 1 1/4" Diameter x 24" Long (20" Embedment & 4" Hook) Rev: Oct 30/07 Page 12 of 12

Preformed Metal Roofing and Siding

Preformed Metal Roofing and Siding Page -1-1. GENERAL 1.1. Description This specification along with the drawings covers the furnishing of all material, products, equipment, accessories, tools, services, transportation, labor and supervision

More information

SECTION 07720 PREFORMED METAL STANDING SEAM ROOFING

SECTION 07720 PREFORMED METAL STANDING SEAM ROOFING SECTION 07720 PREFORMED METAL STANDING SEAM ROOFING PART ONE GENERAL DESCRIPTION This section includes pre-formed standing seam metal roofing and related flashings, closures, trim and accessories including,

More information

Specifications. Preformed Metal Wall and Roof Panels. Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023

Specifications. Preformed Metal Wall and Roof Panels. Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023 Specifications Preformed Metal Wall and Roof Panels Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023 Section 07410 Preformed Metal Wall and Roof Panels Structural

More information

SECTION 07400 STANDING SEAM METAL ROOF

SECTION 07400 STANDING SEAM METAL ROOF SECTION 07400 STANDING SEAM METAL ROOF PART 1 - GENERAL 1.01 SECTION INCLUDES A. Work described in this section includes pre-formed standing seam metal roofing system complete with clips, perimeter and

More information

GUIDELINE SPECIFICATIONS

GUIDELINE SPECIFICATIONS GUIDELINE SPECIFICATIONS GORDON SOFFIT-SHIELD - An Exterior Metal Soffit System DIVISION 05 5800 or DIVISION 07 7700 Note To Specifier: SOFFIT-SHIELD should be installed by tradesmen that are experienced

More information

SECTION 07410 PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK

SECTION 07410 PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK SECTION 07410 PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK A. This section covers the pre-finished, pre-fabricated Architectural standing seam roof system. All metal trim,

More information

PART 1 GENERAL 1.1 SECTION INCLUDES

PART 1 GENERAL 1.1 SECTION INCLUDES J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including

More information

Holiday Inn Express & Suites Covington (Newton County) 1. Standing-seam metal roofing, custom fabricated.

Holiday Inn Express & Suites Covington (Newton County) 1. Standing-seam metal roofing, custom fabricated. PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Standing-seam metal roofing, custom fabricated. 1.2 SUBMITTALS A. Product Data: For each type of product indicated. B. Shop Drawings: Show installation

More information

SECTION 07 61 13 STANDING SEAM METAL ROOFING

SECTION 07 61 13 STANDING SEAM METAL ROOFING SECTION 07 61 13 STANDING SEAM METAL ROOFING PART 1 GENERAL 1.01 SCOPE OF WORK A. The Work shall include all labor, materials, equipment and supervision required to complete the work of the above referenced

More information

Standing Seam Roof Systems

Standing Seam Roof Systems Standing Seam Roof Systems REAL PEOPLE. REAL PRODUCTS. REAL SOLUTIONS. www.a-s.com Building Benefits You Can Expect From A&S Materials Standing Seam roof panels weigh a relatively modest 11/2 pounds per

More information

VALOR STEEL BUILDINGS STANDARD SPECIFICATIONS

VALOR STEEL BUILDINGS STANDARD SPECIFICATIONS VALOR STEEL BUILDINGS STANDARD SPECIFICATIONS For Rigid/I- Beam Construction as designed, engineered, and fabricated by Valor Steel Buildings. General 1.1) Valor shall use standards, specifications, recommendations,

More information

James M. Pleasants Company

James M. Pleasants Company James M. Pleasants Company SUBMITTAL DATA GAINESVILLE MECHANICAL DECEMBER 20, 2013 PROJECT: GSU: J-183 HUMANITIES LAW BLDG. QUOTE NO:12116 ENGINEER: STEVENS & WILKINSON GASKETED PLATE HEAT EXCHANGER Tag:

More information

238T Standing Seam Metal Roof System (SSMRS)

238T Standing Seam Metal Roof System (SSMRS) 238T Standing Seam Metal Roof System (SSMRS) Text in red are instructions to the specifier and should be deleted. Text in blue are choices that need to be made, with those not selected, deleted. McElroy

More information

- - - - Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner

- - - - Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner The Kelly Klosure pre-framed modular panel has 4 components that are factory finished to create an easy and versatile bolt-together system in the field. Steel Panel Frame Exterior Steel Sheeting Optional

More information

Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood

Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood Section 07411 Metal Roof Panels Part 1 General 1.1 Summary A. This section includes the following: a. Factory-formed

More information

The Olympia Difference

The Olympia Difference The Olympia Difference Valued Customer, Thank you for choosing Olympia Steel Buildings as the solution to your building needs. You can be confident that the Olympia team of professionals will provide you

More information

The Butler MR-24 Standing Seam Roof Difference. A comparison between metal roof systems

The Butler MR-24 Standing Seam Roof Difference. A comparison between metal roof systems The Butler MR-24 Standing Seam Roof Difference A comparison between metal roof systems Roof Systems Necessities Weathertight (don t leak!) Low maintenance Weathertightness Roof clips, seams, panel alignment

More information

SECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here) SECTION 08332 COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Counter Fire Doors. 1.2

More information

March 14, 2007. Installation of Bay, Bow and Garden Windows

March 14, 2007. Installation of Bay, Bow and Garden Windows March 14, 2007 Re: Installation of Bay, Bow and Garden Windows Attached are the Atrium Companies, Inc recommendation for the installation of bay, bow and garden windows. These instructions were developed

More information

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590

More information

CHAPTER 7: Building Systems ROOFING SYSTEMS

CHAPTER 7: Building Systems ROOFING SYSTEMS ROOFING SYSTEMS Purpose Examples 1. Shingle roof system 2. Metal roof with blanket insulation 3. Metal roof with rigid insulation 4. Built-up asphalt roof system 5. Single-ply roof system 6. Modified Bitumen

More information

CONSTRUCTION DETAILS & LOAD DESIGN CHARTS

CONSTRUCTION DETAILS & LOAD DESIGN CHARTS Office and Production 126 New Pace Rd., PO Box 279 Newcomerstown, OH 43832 1-800-446-2188, Fax: 740-498-4184 www.buildwithsips.com CONSTRUCTION DETAILS & LOAD DESIGN CHARTS Table of Contents Description

More information

SECTION 07410 METAL ROOF & WALL PANELS

SECTION 07410 METAL ROOF & WALL PANELS This document specifies Metal Roofing Systems prefinished factory formed metal roofing marketed as MRS System 2500 steel and aluminum roofing systems and includes MRS flashing and Trim. MRS finish is a

More information

SECTION 07411 STANDING SEAM METAL ROOFING

SECTION 07411 STANDING SEAM METAL ROOFING PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following: 1. Standing-seam metal roof. 2. Metal gutters. 1.2 DEFINITIONS A. Metal Roof Panel Assembly: Metal roof panels, waterproofing membrane (underlayment),

More information

Table of Contents. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide. Notes to Designer /Installers..

Table of Contents. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide. Notes to Designer /Installers.. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide Table of Contents Section Page Section Page Notes to Designer /Installers.. 1 Fastener Placement and Selection.2-3

More information

SPECIFICATION Section 03450 - Insulated Precast Concrete Wall Panels

SPECIFICATION Section 03450 - Insulated Precast Concrete Wall Panels Lafarge/CPCI Guide Specification SPECIFICATION Section 03450 - Insulated Precast Concrete Wall Panels 1.0 General 1.1 Description.1 The General conditions of the Contract and Supplementary General Conditions

More information

BRIDGE & SUPPLY COMPANY. Installation Guide. Ultra 2000. Includes:

BRIDGE & SUPPLY COMPANY. Installation Guide. Ultra 2000. Includes: BRIDGE & SUPPLY COMPANY Installation Guide Ultra 2000 Includes: Ultra 2000 Installation Guide Stock Trim Profiles Ultra 2000 Trim Installation Guide Page 2 Table of Contents Ultra 2000 Profile, Colors

More information

Window Installation Instructions

Window Installation Instructions Caution The correct installation methods of windows in full frame or insert applications is critical towards achieving the tested performance of the window and longterm enjoyment and energy savings for

More information

Nucor VR16 II TM Vertical Rib Standing Seam Roof System

Nucor VR16 II TM Vertical Rib Standing Seam Roof System Nucor VR16 II TM Vertical Rib Standing Seam Ro System www.nucorbuildingsystems.com Nucor VR16 II Vertical Rib Standing Seam Ro Perfect for the Marketplace The Nucor Building Systems VR16 II Ro Panel is

More information

1.02 SYSTEM DESCRIPTION

1.02 SYSTEM DESCRIPTION 1 OF 7 MODULAR MEZZANINES GUIDE SPECIFICATIONS FOR PART 1 - GENERAL 1.01 RELATED WORK A. SECTION 03 30 00: Cast in Place Concrete (and Concrete Finishing) 1. The area where mezzanine is installed shall

More information

DENVER MODEL 30 X 30 SPECIFICATIONS

DENVER MODEL 30 X 30 SPECIFICATIONS DENVER MODEL 30 X 30 SPECIFICATIONS Dimensions: Roof Dimensions 30-0 x 30-0 (4) Columns (Center to Center) 25-6½ x 25-6½ Minimum Clearance 8-0 Roof Height @ Peak Dependent on Col. Ht. Hip Roof 4:12 pitch

More information

INSTALLATION OF A BAY WINDOW

INSTALLATION OF A BAY WINDOW INSTALLATION OF A BAY WINDOW Installation of a Bay Window These instructions relate to the replacement of an existing bay window or replacement of a straight window with a new bay window, in an opening

More information

PROPOSED SPECIFICATION FOR ALUCOBOND PLUS Aluminium Composite Panel Cladding System Fixed Watertight Cassette Panel System - 4mm thick

PROPOSED SPECIFICATION FOR ALUCOBOND PLUS Aluminium Composite Panel Cladding System Fixed Watertight Cassette Panel System - 4mm thick 1. SCOPE OF WORK The scope of work includes the design, supply fabrication and installation of Alucobond PLUS aluminium composite panel cladding, complete with all necessary sub-structures, anchors, hardware

More information

COLORADO MODEL. 35 x 65 SPECIFICATIONS

COLORADO MODEL. 35 x 65 SPECIFICATIONS COLORADO MODEL 35 x 65 SPECIFICATIONS Dimensions: Roof Dimensions 35-0 x 65-0 Column Dimensions (center to center) 31-0 x 30-6 Minimum Clearance 14-0 Roof Height @ Peak ±18-8 Curved Roof ±42-6 radius Square

More information

PRODUCT SPECIFICATIONS

PRODUCT SPECIFICATIONS LokSeam LokSeam 12" One of the most versatile architectural metal panels available today, LokSeam by ABC, is a snap-together, concealed fastener, standing seam roof system with a 13/4" tall vertical rib,

More information

SECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE

SECTION 15076 CEMENT-MORTAR LINED AND COATED STEEL PIPE SECTION 15076 CEMENT-MORTAR LINED AND COATED (CML&C) STEEL PIPE PART 1 GENERAL 1.01 DESCRIPTION This section designates the requirements for steel pipe fabrication, test in shop, installation of steel

More information

PANELIZED HOME INSTALLATION GUIDELINE

PANELIZED HOME INSTALLATION GUIDELINE PANELIZED HOME INSTALLATION GUIDELINE A typical home package will be constructed of Snap-N-Lock Insulated Panels clad with steel skins. 4" panels will be used for the walls, and 6" panels for the roof.

More information

Residential Roofing Guide

Residential Roofing Guide Residential Roofing Guide TABLE OF CONTENTS Building Detail and Accessories...... 1 Panel Introduction and Handling...... 2 Cutting and Trimming.... 3 Roof Preparation..... 3 Roof Slope..... 3 Re-roofing...

More information

ATLANTA MODEL SPECIFICATIONS

ATLANTA MODEL SPECIFICATIONS ATLANTA MODEL 50 SPECIFICATIONS Dimensions: Roof Dimensions (point to point) 50-0 Column Dimensions (out to out of columns) 44-0 Eave Height 8-0 Roof Height @ Peak ±21-8⅞ Hip Roof 6:12 pitch Square Feet

More information

Sun Windows General Information Sun New Construction Window Installation Instructions

Sun Windows General Information Sun New Construction Window Installation Instructions Sun Windows General Information Section 1 G F H H H A. Apply Weather Resistive Barrier B. Apply Sill Flashing Tape C. Place Waterproof Sill Shims D. Caulk Back of Nail Fin Sides & Top, Set Window, Fasten

More information

Table of Contents. Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide

Table of Contents. Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide Table of Contents Section Page Section Page Notes to Designer /Installers.. 1 Fastener Placement and Selection.2-3

More information

STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS

STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS ROOFING APPLICATION STANDARD (RAS) No. 133 STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS 1. Scope 1.1 This application standard has been developed to provide consistent information for the

More information

STANDING SEAM SHEET METAL ROOFING

STANDING SEAM SHEET METAL ROOFING STANDING SEAM SHEET METAL ROOFING GENERAL INFORMATION 1.1 For all standing seam metal roofing work consult Columbia University Facilities Exteriors and Historic Preservation group. 1.2 Fabricator is responsible

More information

INSTALLATION. General. Important Note. Design. Transport

INSTALLATION. General. Important Note. Design. Transport General The roof trusses you are about to install have been manufactured to precise engineering standards. To ensure that the trusses perform as designed, it is essential that they be handled, erected

More information

SECTION 07 42 13 METAL WALL PANELS

SECTION 07 42 13 METAL WALL PANELS Mitsubishi Plastics Composites America, Inc. 401 Volvo Parkway Chesapeake, VA 23320 Phone: (800) 422-7270 Fax: (757) 436-1896 E-mail: info@alpolic.com www.alpolic-northamerica.com This MANU-SPEC utilizes

More information

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM Chapter 9 STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM 9.1 BACKGROUND Steel is widely used in the construction of multi-storey buildings. However, steel construction is seldom used and is traditionally

More information

SELF-STORAGE BUILDINGS

SELF-STORAGE BUILDINGS SELF-STORAGE BUILDINGS QUALITY and RELIABILITY The self-storage business has grown into a multi-billion dollar industry. Current businesses are expanding and new companies are starting up every day. The

More information

City of San Diego, CWP Guidelines

City of San Diego, CWP Guidelines PART 1 -- GENERAL SECTION 08520-1.1 WORK OF THIS SECTION City of San Diego, CWP Guidelines A. The WORK of this Section includes providing aluminum windows with frames, bracing, glazing attachments, screens,

More information

Metal Building Systems Installation and Flashings & Details Guide. Table of Contents

Metal Building Systems Installation and Flashings & Details Guide. Table of Contents Table of Contents Section Page Notes to Designer/User..................1-2 Map of Typical Roof Conditions............3 Fastener Placement.......................4 Fastener Selection........................5

More information

SECTION 6. Glass Storefront Doors:

SECTION 6. Glass Storefront Doors: SECTION 6 Glass Storefront Doors: Table of Contents 3070 Storefront Door System Description & Dimensions 6070 Storefront Door System Description & Dimensions Door Leaf Detail Optional 10 Bottom Rail Detail

More information

Slim Seam Architectural Design Manual

Slim Seam Architectural Design Manual Slim Seam Architectural Design Manual Headquarters: 3449 Hempland Road Lancaster, PA 17601 Phone: 800-477-2741 Fax: 800-283-4289 Architectural Products Division: 308 Alabama Blvd. Jackson, GA 30233 Phone:

More information

1. The General conditions of the Contract and Supplementary General Conditions apply to this Division, except as qualified herein and/or excluded.

1. The General conditions of the Contract and Supplementary General Conditions apply to this Division, except as qualified herein and/or excluded. Lafarge/CPCI Guide Specification SPECIFICATION Section 03450 - Architectural Precast Concrete 1.0 General 1.1 Description 1. The General conditions of the Contract and Supplementary General Conditions

More information

VA25014B0516 VA CINCINNATI PROJECT NO. 539-328 INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION 09 29 00 GYPSUM BOARD

VA25014B0516 VA CINCINNATI PROJECT NO. 539-328 INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION 09 29 00 GYPSUM BOARD SECTION 09 29 00 GYPSUM BOARD PART 1 - GENERAL 1.1 DESCRIPTION This section specifies installation and finishing of gypsum board, vapor retarder and air and moisture barrrier. 1.2 RELATED WORK A. Installation

More information

Sports and High Mast Lighting Poles Phone: (866) 474-7200 Fax: (817) 924-7049

Sports and High Mast Lighting Poles Phone: (866) 474-7200 Fax: (817) 924-7049 Sports and High Mast Lighting Poles 4 High Mast Lighting Poles General American LitePole offers a raising and lowering system that allows for ease of maintaining the lighting system at ground level. Ideal

More information

INSTALLATION MANUAL For Grand Rib-3 / Multi Purpose / & Classic Rib Roofing Panels

INSTALLATION MANUAL For Grand Rib-3 / Multi Purpose / & Classic Rib Roofing Panels INSTALLATION MANUAL For Grand Rib-3 / Multi Purpose / & Classic Rib Roofing Panels Grand Rib-3 / Multi-Purpose / Classic Rib Grand Rib-3 / Multi-Purpose / & Classic Rib Grand Rib 3 panels are a strong,

More information

METAL BUILDING SYSTEMS

METAL BUILDING SYSTEMS BUILDING SYSTEMS The Brand of Choice METAL BUILDING SYSTEMS www.nucorbuildingsystems.com Building Systems The Brand of Choice Nucor Building Systems, a division of Nucor Corporation, is one of the most

More information

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES 101 Retrofits Required. Pursuant to Section 553.844 553.884, Florida Statutes, strengthening of existing site-built,

More information

September 3, 2009. Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901

September 3, 2009. Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901 September 3, 2009 Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901 RE: Ketchikan Gateway Borough Gateway Recreation Center Roof Observations and Intrusive Inspections

More information

PERIMETER FLASHING. Table of Contents

PERIMETER FLASHING. Table of Contents FM Global Property Loss Prevention Data Sheets 1-49 February 1985 Revised September 2000 Page1of25 PERIMETER FLASHING Table of Contents Page 1.0 SCOPE... 3 1.1 Changes... 3 2.0 LOSS PREVENTION RECOMMENDATIONS...

More information

SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word

More information

SECTION 15140 - PIPE HANGERS AND SUPPORTS

SECTION 15140 - PIPE HANGERS AND SUPPORTS Part I - GENERAL 1.01 SECTION INCLUDES A. The work covered under this section consists of the furnishing of all necessary labor, supervision, materials, equipment, and services to completely execute the

More information

SECTION 230529 - HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

SECTION 230529 - HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT SECTION 230529 - PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Steel pipe hangers and supports. 2. Metal framing systems. 3. Thermal-hanger shield inserts. 4. Fastener systems.

More information

Tundra Series Windows January 2016

Tundra Series Windows January 2016 Tundra Series Windows January 2016 New Construction Installation Instructions Nail Fin, J-Fin and Brickmold Aplications product. ATTENTION! Read and understand all installation instructions before installing

More information

TABLE OF CONTENTS. Roof Decks 172 B, BA, BV Deck N, NA Deck. Form Decks 174.6 FD,.6 FDV Deck 1.0 FD, 1.0 FDV Deck 1.5 FD Deck 2.0 FD Deck 3.

TABLE OF CONTENTS. Roof Decks 172 B, BA, BV Deck N, NA Deck. Form Decks 174.6 FD,.6 FDV Deck 1.0 FD, 1.0 FDV Deck 1.5 FD Deck 2.0 FD Deck 3. Pages identified with the NMBS Logo as shown above, have been produced by NMBS to assist specifiers and consumers in the application of New Millennium Building Systems Deck products. Pages identified with

More information

Asphalt Shingle Application Requirements

Asphalt Shingle Application Requirements Alberta Allied Roofing Association Asphalt Shingle Application Requirements Section 1 Roof Decks 1.1 General Asphalt Shingles are not permitted to be installed directly over rigid insulation. When Asphalt

More information

SECTION 07 41 13.16 - STANDING-SEAM METAL ROOF PANELS PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION 07 41 13.16 - STANDING-SEAM METAL ROOF PANELS PART 1 - GENERAL 1.1 RELATED DOCUMENTS SECTION 07 41 13.16 - STANDING-SEAM METAL ROOF PANELS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

SECTION 02630 STORM DRAINAGE SYSTEM

SECTION 02630 STORM DRAINAGE SYSTEM SECTION 02630 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes specifications for storm drainage systems including modifications and connections to existing storm drainage systems. 1.02 REFERENCE

More information

POST AND FRAME STRUCTURES (Pole Barns)

POST AND FRAME STRUCTURES (Pole Barns) POST AND FRAME STRUCTURES (Pole Barns) Post and frame structures. The following requirements serve as minimum standards for post and frame structures within all of the following structural limitations:

More information

Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION

Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION SIPS SCREWS WITH MINIMUM 1" PENETRATION IN WOOD MEMBER IN SIP WALL PANEL CONNECTED TO @ 24" O.C. MAXIMUM OUTSIDE SKIN EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY FOAM CORE AS EACH SIDE OF FRAMING TYP.

More information

Installation Manual for STANDING SEAM ROOFING

Installation Manual for STANDING SEAM ROOFING Installation Manual for STANDING SEAM ROOFING Absolute Steel Toll Free 877-833-3237 / Phone 480-768-1618 / Fax 480-768-1514 www.metalroofingsource.com Standing Seam features approximately one-inch high

More information

HHS J.W. Peavy Center Exterior Walls Waterproofing and Roof Replacement Project WBS # H-000018-0006-4 SECTION 07610 STANDING SEAM METAL ROOFING

HHS J.W. Peavy Center Exterior Walls Waterproofing and Roof Replacement Project WBS # H-000018-0006-4 SECTION 07610 STANDING SEAM METAL ROOFING PART 1 - GENERAL 1.01 DESCRIPTION SECTION 07610 A. Furnish and install a weather and watertight prefabricated standing seam roof system complete, in place, as shown on the drawings and as specified herein.

More information

VERTICAL LOCK Table of Contents

VERTICAL LOCK Table of Contents Table of Contents TABLE OF CONTENTS Vertical Lock Product Data Sheet... 2 Vertical Lock Engineering Data... 3 General Information... 6 Material Testing... 7 Panel Overview... 8 Handling Material & Storage

More information

Rouse Life Sciences Roof Repair or Replacement 07 61 13 SECTION 07 61 13

Rouse Life Sciences Roof Repair or Replacement 07 61 13 SECTION 07 61 13 1. PART 1 - GENERAL 1.1 DESCRIPTION OF WORK SECTION 07 61 13 STANDING SEAM METAL ROOFING 1. This Section covers the pre-finished, pre-fabricated Architectural standing seam roof system. All metal trim,

More information

Product Catalog. Extreme Roofing, Inc. 2680 Rt. 982 Mammoth, PA 724.838.7695 www.extremeroofinginc.com

Product Catalog. Extreme Roofing, Inc. 2680 Rt. 982 Mammoth, PA 724.838.7695 www.extremeroofinginc.com 2012 Product Catalog Extreme Roofing, Inc. 2680 Rt. 982 Mammoth, PA 724.838.7695 www.extremeroofinginc.com 2 PH. 724.838.7695 Email. sales@extremeroofinginc.com Website. www.extremeroofinginc.com Fax.

More information

A. Double lock standing seam, single element, metal roof panels.

A. Double lock standing seam, single element, metal roof panels. Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions SECTION 07 41 13 METAL ROOF PANELS Morin Metal Panels Double Lock Standing Seam Metal Roof Panels PART 1 - GENERAL 1.1

More information

DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION SECTION: 07 41 13 METAL ROOF PANELS REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC

DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION SECTION: 07 41 13 METAL ROOF PANELS REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC 0 ICC ES Report ICC ES (800) 423 687 (62) 699 043 www.icc es.org 000 Most Widely Accepted and Trusted ESR 3422 Reissued 09/201 This report is subject to renewal 09/2016. DIVISION: 07 00 00 THERMAL AND

More information

Screw Patterns Roof & Walls 403-279-2766 TR-36 MD-36 TSM-32. PBR-Panel

Screw Patterns Roof & Walls 403-279-2766 TR-36 MD-36 TSM-32. PBR-Panel Screw Patterns Roof & Walls Overlap Underlap ¾ 9 TR-36 36 5/8 6 MD-36 36 ½ 8 TSM-32 32 1¼ 12 PBR-Panel 36 Bottom Edge Screw Pattern apply to every profile except for MD36 (1 screw beside every rib) High

More information

Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows

Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows americancraftsmanwindows.com Project Requirements: Read

More information

TARIFF CODE and updates standard

TARIFF CODE and updates standard TARIFF CODE and updates standard No HS CODE AHTN CODE PRODUCT DESCRIPTION PRODUCT TYPE STANDARDS IDENTIFIED 7207 Semi finished products of iron or non alloy steel Containing by weight less than 0.25% of

More information

application instructions

application instructions application instructions ARCHITECTURAL COLLECTION PRIMED BOLD PROFILE 120 SERIES LAP SIDING (D5, T4, D8, T5, Q4) General At the time of manufacture, siding meets or exceeds the performance standards set

More information

Display hidden notes to specifier. (Don't know how? Click Here) A. Advanced Upcoiling Security Grilles, power operated.

Display hidden notes to specifier. (Don't know how? Click Here) A. Advanced Upcoiling Security Grilles, power operated. SECTION 08333 ADVANCED UPCOILING SECURITY GRILLE MODEL 600 ADV Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Advanced Upcoiling Security Grilles,

More information

SPECIFICATION Section 03410 - Structural Precast / Prestressed Concrete

SPECIFICATION Section 03410 - Structural Precast / Prestressed Concrete Lafarge/CPCI Guide Specification SPECIFICATION Section 03410 - Structural Precast / Prestressed Concrete 1.0 General 1.1 Description.1 The General conditions of the Contract and Supplementary General Conditions

More information

Discount Direct Metal Roofing Plus Rib Roofing Panels Installation Instructions

Discount Direct Metal Roofing Plus Rib Roofing Panels Installation Instructions Discount Direct Metal Roofing Plus Rib Roofing Panels Installation Instructions All questions and concerns please call 904-696-9700 Discount Direct Metal Roofing Plus Rib metal roofing panels are a strong,

More information

112039.00 SECTION 074113.16 STANDING-SEAM MEAL ROOF PANELS

112039.00 SECTION 074113.16 STANDING-SEAM MEAL ROOF PANELS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.

More information

Federal Steel Systems: Metal Building Terminology

Federal Steel Systems: Metal Building Terminology Federal Steel Systems Federal Steel Systems: Metal Building Terminology 925 S. Niagara Street, Suite 250 Denver, Colorado 80224 Toll-Free: 1-855-885-9570 info@federalsteelsystems.com http://federalsteelsystems.com

More information

THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150

THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150 THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150 SECTION ONE A. Objective The objective of this guide is to provide Owners and General Contractors/Construction

More information

Storage Store the siding in a dry and ventilated area. Do not place it directly on the ground. Always cover the siding after a day s work.

Storage Store the siding in a dry and ventilated area. Do not place it directly on the ground. Always cover the siding after a day s work. Installation Guide Before you begin, take the time to read this entire guide to clearly understand the requirements and steps to follow for proper installation. Warning Do not install defective material.

More information

Residential Deck Safety, Construction, and Repair

Residential Deck Safety, Construction, and Repair Juneau Permit Center, 4 th Floor Marine View Center, (907)586-0770 This handout is designed to help you build your deck to comply with the 2006 International Residential Building code as modified by the

More information

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM Installed in Pre-engineered Steel Buildings Provides Lowest Cost Construction Method for CORROSIVE AND WET Environments PREFERRED SOLUTIONS, INC.

More information

A. The shade structure contractor shall be responsible for the design, engineering, fabrication, and supply of the work specified herein.

A. The shade structure contractor shall be responsible for the design, engineering, fabrication, and supply of the work specified herein. 13310 FABRIC SHADE STRUCTURES FOR PLAYGROUND AREAS ************************************************************************************************************************ SPECIFIER: CSI Master Format

More information

SECTION 07 21 16 - PRE-ENGINEERED BUILDING BLANKET INSULATION

SECTION 07 21 16 - PRE-ENGINEERED BUILDING BLANKET INSULATION PROJECT ARCHITECT RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment.

More information

TABLE OF CONTENTS" SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE 7"

TABLE OF CONTENTS SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE 7 2 TABLE OF CONTENTS SECTION 1: What is a Standing Seam Metal Roof PAGE 3 SECTION 2: Common Types of Standing Seam Metal Roofs..PAGE 5 SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE

More information

Chapter 36 - STRAW BALE CONSTRUCTION SECTION 3601 - PURPOSE. SECTION 3602 - SCOPE. SECTION 3603 - DEFINITIONS.

Chapter 36 - STRAW BALE CONSTRUCTION SECTION 3601 - PURPOSE. SECTION 3602 - SCOPE. SECTION 3603 - DEFINITIONS. Austin City Code - Volume II TITLE 25 LAND DEVELOPMENT\CHAPTER 25-12 TECHNICAL CODES\ARTICLE 1: UNIFORM BUILDING CODE\25-12-3 LOCAL AMENDMENTS TO THE BUILDING CODE Chapter 36 - STRAW BALE CONSTRUCTION

More information

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions SECTION 07 42 13 METAL WALL PANELS

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions SECTION 07 42 13 METAL WALL PANELS Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions SECTION 07 42 13 METAL WALL PANELS Concealed Fastener Metal Wall Panels PART 1 - GENERAL 1.1 SECTION INCLUDES A. [Concealed

More information

SECTION 07410 METAL ROOF SYSTEM

SECTION 07410 METAL ROOF SYSTEM SECTION 07410 METAL ROOF SYSTEM PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and General Provisions of Contract, including General Conditions and other Division 1 Specification Sections, apply to

More information

A D D E N D U M # 3 QUESTIONS FROM BIDDERS: DATE: November 5, 2012. All Bidders. Jenne dos Santos, CBI Consulting Inc. City of Chelsea, MA

A D D E N D U M # 3 QUESTIONS FROM BIDDERS: DATE: November 5, 2012. All Bidders. Jenne dos Santos, CBI Consulting Inc. City of Chelsea, MA Page 1 of 10, Addendum No. 3 Temporary Garage Structure City of Chelsea, MA November 5, 2012 CBI Job No.: 12055-A A D D E N D U M # 3 DATE: November 5, 2012 TO: FROM: PROJECT: All Bidders Jenne dos Santos,

More information

Retrofitting an Insulated Cold Roof

Retrofitting an Insulated Cold Roof Retrofitting an Insulated Cold Roof As a metal-roofing contractor in the Upper Peninsula of Michigan, I am frequently asked to fix roof leaks that have less to do with roofing than with the way poorly

More information

Metal Roofing Practical Design

Metal Roofing Practical Design Metal Roofing Practical Design Metal Roofing Practical Design Learning Outcomes Minimum Requirements Design Resources Low Slope Metal Roofing Design Details Continuously Insulated (Ci) Systems Minimum

More information

Installation Window Building In Details

Installation Window Building In Details Installation Window Building In Details INSTALLATION Photo courtesy of Rowe Aluminium DATE: NOVEMBER 2009 REPLACES: AUGUST 2003 INSTALLATION Installation Replaces: Scale: NOT TO SCALE Vantage snap-on couplers

More information

Introduction...COMB-2 Design Considerations and Examples...COMB-3

Introduction...COMB-2 Design Considerations and Examples...COMB-3 SECTION DIRECTORY General Information Introduction...COMB-2 Design Considerations and Examples...COMB-3 Combination Assembly Recommendations and Limitations Composite Configurations...COMB-4 Typical Sealant

More information