Air Filtration System for Animal Transport Vehicles
|
|
- Branden O’Brien’
- 7 years ago
- Views:
Transcription
1 Air Filtration System for Animal Transport Vehicles Project Team Bernardo Predicala, Prairie Swine Centre Inc. Lee Whittington, Prairie Swine Centre Inc. Francis Pouliot / Jacquelin Labrecque, CDPQ Henry Gauvreau, Warman Veterinary Services Sylvain Messier, Demeter Services Vétérinaires Inc. Brent Jones, South West Ontario Veterinary Services Angus Chambers, JSR Genetics Funding Canadian Swine Health Board Canadian Agricultural Adaptation Program
2 Project Overview Background Recognized risk of infection during transport Close the biosecurity gap, in conjunction with filtered barns Project goal Develop and evaluate an air filtration system for a transport trailer to protect pigs from potential risk of infection Specific objectives: 1. Investigate options for different components of a trailer filtration system 2. Design a practical air filtration system that can be applied under Canadian conditions 3. Construct a prototype pig transport trailer with filtration 4. Evaluate effectiveness of the filtered-trailer system 2
3 Project Activities Phase 1 Literature review and survey of existing filtered trailer/trucks designs Number of filtered truck designs surveyed: 2 from France, 2 from Netherlands, 4 from U.S. European truck companies namely Berdex (Netherlands), Cuppers (Netherlands), and Guitton (France) supply filtered trucks to different swine production companies/organizations in Europe. 3
4 Existing filtered trailers Organization Trailer Length Cap50 Porcs (France) 40 to 45 ft (12 to 13.7 m) Berdex Hermitage-NGT PIC US SRTC-UWM (Netherlands) 45.4 ft (13.85 m) 53 ft (16 m) 32 ft (9.75 m) 20 ft (6.1 m) Number of Decks 1 1,2,3, Capacity per deck 214 (50-lb pigs) 170 (50-lb pigs) 93 (50-lb pigs) Fan Type Axial High-Pressure Fan Axial Axial Negative Air Machine Ventilation Rate per deck Low (oxygen is being monitored) High, Max 4,500 CFM Low, Max 500 CFM Maximum Static 1.4 inch water no setting 3 inch water Pressure Filter Type HEPA HEPA + UV lights HEPA DOP HEPA, DOP Air Conditioning Power Requirement Yes (Refrigeration unit) ~ 20,000 W Yes No No Yes (3 4,000 W-units) 5,500 W 10,000 W Cost (Refrigeration unit) $124K 3-deck $30K $40K parts $150K 4-deck $20K labor, misc Travel Time 24 hours 36 hours, rest every 5 16 hours (maximum) hours Floor Bedding No Yes Yes 4
5 Existing filtered trailers PIC, U.S.A.: (Photos courtesy of Bob Thompson) 5
6 6 Existing filtered trailers
7 Existing filtered trailers Europe Berdex (Netherlands) Cuppers (France) 7
8 8 Existing filtered trailers
9 9 Existing filtered trailers
10 10 Existing filtered trailers
11 Existing trailer cost estimate SRTC-UW Trailer: 20 x 7 x 7 gooseneck; capacity: lb pigs, lb pigs 11
12 Existing trailer cost estimate 12 SRTC-UW Trailer: 20 x 7 x 7 gooseneck; capacity: lb pigs, lb pigs Equipment cost Share (%) Ventilation $6,000 15% Filter $900 (HEPA) 2% $450 (DOP) A/C & Heating system $6,000 15% Power $20,000 50% (10kW generator) Insulation $7,000 18% Total $40,000 Trailer capital and labour costs (~$20,000) and miscellaneous items (~$7,000) not included.
13 Design challenges Ventilation Minimum ventilation per animal (summer and winter conditions) Leakage and unintended inlets; filtered air distribution Heat and moisture production in enclosed space Air flow resistance; power requirement System performance monitoring filter, air quality Emergency measures - in case of equipment failure Feeding and watering system Cleaning and disinfection Cost 13
14 Trailer Components - options Temperature control Filtration Fan Air Distribution Ventilation HEPA Axial Poly bag duct Air Conditioned MERV16 Centrifugal PVC pipe Combination MERV14 Cross ventilation Antimicrobial [None] 14 For the above options = 24 to 96 potential trailer configurations! Evaluation criteria (to select the option to include in the design): - cost, power requirement, robustness, resulting trailer environment (air quality, thermal conditions).
15 Phase 2 Construction and testing Design of filtration system - selected options Environment control non-airconditioned, mechanically-ventilated Filter MERV 16 filters Air mover axial fan Air distribution no air diffuser 15
16 Phase 2 Schematic diagram of trailer filtration system retrofit Air inlets Filter Fan Air outlets 16
17 Phase 2 Trailer retrofit: 17
18 18 Phase 2
19 19 Phase 2
20 Phase 2 Trailer test bacteriophage φx174 aerosol 20
21 Phase 2 Bag (antimicrobial fabric) filter: 21
22 Phase 2 Trailer testing: 22
23 Results Trailer testing MERV 16 filter 23
24 Results Trailer testing antimicrobial fabric filter 24
25 Summary Information available on design components for a trailer filtration system Antimicrobial filters (MERV 16, fabric filter) can capture bioaerosols in the airstream and prevent entry to animal compartment Specific design challenges were identified: 25
26 Challenges Ventilation rate requirements - no standard Size of fans, motors Significant airflow restriction high HP Target filter efficiency infective dose Power supply capacity, quality Leakage controlled airflow, wind effect Keep things simple controls, monitors Cost 26
27 Emergency Biocontainment System for Swine Facilities to Control Transmissible Airborne Diseases Project Team Bernardo Predicala, Prairie Swine Centre Inc. Lee Whittington, Prairie Swine Centre Inc. Francis Pouliot / Jacquelin Labrecque, CDPQ Sylvain Messier, Demeter Services Vétérinaires Inc. Henry Gauvreau, Warman Veterinary Services Brent Jones, South West Ontario Veterinary Services Funding Canadian Swine Health Board Canadian Agricultural Adaptation Program
28 Project Overview Develop alternatives to current means of dealing with airborne disease outbreaks Project goal: Investigate potential measures for emergency biocontainment of a barn during an outbreak Specific objectives: 1. Compile measures and strategies that can potentially be applied for isolating a barn during an airborne disease outbreak 2. Evaluate effectiveness of selected measures in pilot scale 3. Develop best management practices and communication/ coordination protocols to be implemented during emergency biocontainment 28
29 Exhaust bag-type filter Photo courtesy: Brent Jones 29
30 Filtered enclosure Photo source: Baumgartner Environics Inc. 30
31 31 Dust reduction curtain
32 32 Trailer with filter walls
33 33 Other exhaust filter options
34 Assessment criteria a. time required for installation - within 1 or 2 days after an outbreak is detected b. operational and maintenance requirements - minimal technical expertise and manpower needed for set-up and operation c. portability and adaptability for installation - adaptable to different existing barn configurations d. robustness and reliability of performance - must function reliably over biocontainment period e. affordability - total cost must not offset the benefits of biocontainment; reusable measures 34
35 Option Rank Comments Assessment results Bag-type filter at exhaust Dust control curtain at exhaust 1 2 Dust removal before filter pre-filter (easily installation), upwind directed pre-filter and filter(gravitational settling), Filter- non-collapsible, ability to fit to different sized exhaust, easy air tight attachments (wet suit zippers, Velcro), mechanical support Reduce pressure drop - fan inside the filtration system Maintenance- detection - measure dust level, pressure drop, Combination with dust control curtain Air outlet attachment to curtain horizontal plane at ground level, modified wind hood, pipe Effectiveness virus dissemination, snow accumulation Trailer fitted with mechanical filters Filter roll assembly at exhaust Flexible filter housing (green house style) 35 3 Constraint - Installation issue, long hoses, complex, number of trailers 4 Constraint - installation, maintenance, incomplete seal, higher filter surface area (cost, pressure drop) 5 Constraint installation, snow and water at bottom of the cover, snow load in the covered area
36 36 Pilot-scale test set-up
37 37 Test set-up
38 Test set-up Downstream sampling port Test section Upstream sampling port Aerosol injection port HEPA filter Fan HEPA filter Experimental set-up located at IRDA. 38
39 39 Aerosol measurement
40 Measures tested (a) (b) (c) Photo of the tested measures: (a) Noveko antimicrobial filter; (b) Noveko prefilter; and (c) dust reduction curtain. 40
41 Measures / configuration tested Test results Air flow rate (m 3 h -1 ) P across test section (in. H 2 O) Reduction in aerosolized particles (%) NF (10 layers) with pre-filter NF(20 layers) with pre-filter NF (10 layers) with pre-filter 1156 > DRC1 (4 layers) - attached DRC1 (2 layers) - attached DRC1 (2 layers) - attached with NF (20 layers) NF (20 layers) no pre-filter NF (15 layers) with pre-filter NF (15 layers) with pre-filter 1156 > NF (15 layers) with DRC2 (4 layers) - detached NF (15 layers) with DRC2 (4 layers) - detached 1156 > NF - Noveko filter; DRC dust reduction curtain; P pressure drop 41
42 Next steps Full-scale testing of selected measures Incorporate into Best Management Practices and Emergency Response Protocol documents Assemble a prototype emergency trailer 42
43 43 Questions?
SEPARATING DUST PARTICLES USING AN AERODYNAMIC DEDUSTER
SEPARATING DUST PARTICLES USING AN AERODYNAMIC DEDUSTER DEVELOPMENT OF AN AERODYNAMIC DEDUSTER FOR LIVESTOCK BUILDINGS G.A. Zhao, Y. Zhang Summary Dust is among the major pollutants that have a detrimental
More informationHOSPITAL ISOLATION ROOM HVAC SYSTEM DESIGN
HOSPITAL ISOLATION ROOM HVAC SYSTEM DESIGN Presented to: ASHRAE YEA Illinois Chapter Specialty Environment Design Conference March 24, 2014 Jean O. Gibbons, PE, LEED AP Senior Vice President Grumman/Butkus
More informationINSTRUCTIONS FOR HOW TO PROPERLY SELECT A FAN OR BLOWER
INSTRUCTIONS FOR HOW TO PROPERLY SELECT A FAN OR BLOWER The instructions that follow are to assist you in completing the information required when making a fan or blower selection. If you need additional
More informationEACO DOP / PAO TESTING GUIDELINE 2013
2013 Foreword The guideline promotes industry standards for training, equipment, and methodologies for HEPA filter integrity testing of negative air units, vacuums and any other HEPA filtered equipment
More informationSubpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,
4658.4500 PLUMBING SYSTEMS; NEW CONSTRUCTION. Subpart 1. Installation. All plumbing systems must be installed and tested according to this chapter and chapter 4715, the Minnesota Plumbing Code. Subp. 2.
More informationConstruction Indoor Air Quality Management Plans for LEED. Matt Gregg, PE, LEED AP
Construction Indoor Air Quality Management Plans for LEED Matt Gregg, PE, LEED AP Agenda What is a Construction IAQ Management Plan? What are the LEED Requirements? What is the Mechanical Contractor s
More informationHEPA-filtered Negative Air Machines and their Role in Creating Airborne Infection Isolation Rooms with the ECU AnteRoom. Frequently Asked Questions
HEPA-filtered Negative Air Machines and their Role in Creating Airborne Infection Isolation Rooms with the ECU AnteRoom Frequently Asked Questions What is a negative air machine and why do I need one?
More informationExisting Housing Stock
1 How Old and New Houses Use Energy Total Consumption per Household, 2001 120 100 2: RENOVATION - CONCORD, MA million per household 80 60 40 20 Space Heating Electric Air Conditioning Water Heating Refrigerators
More informationUNIVERSITY OF MISSOURI 23 0000 - Heating Ventilating and Air-Conditioning (HVAC) March 2015.01
GENERAL: This section provides general standards for overall sizing and design of Heating, Ventilating, and Air Conditioning (HVAC) systems. Other sections contain specific standards for each system per
More informationSolar air collectors for industry and larger halls S Ø. Efficient dehumidification and air heating for free...
Solar air collectors for industry and larger halls N S Ø Efficient dehumidification and air heating for free... This booklet contains information about SolarVenti Industrial air solar system. The system
More informationGlossary of Heating, Ventilation and Air Conditioning Terms
Glossary of Heating, Ventilation and Air Conditioning Terms Air Change: Unlike re-circulated air, this is the total air required to completely replace the air in a room or building. Air Conditioner: Equipment
More informationFans and Air Handling Units. Will Rea and Paul Pilutti February 16 th, 2011
Fans and Air Handling Units Will Rea and Paul Pilutti February 16 th, 2011 HTS Lunch and Learns Available Online Visit www.htseng.com Engineering Tools Resource Center Contents Fans Fan Curves Fan Laws
More informationRobert McCabe Director, Health Care Solutions HTS Chicago. Improved Air Quality and Energy Efficiency through Air Handler Filtration System Upgrade
Robert McCabe Director, Health Care Solutions HTS Chicago Improved Air Quality and Energy Efficiency through Air Handler Filtration System Upgrade Biography Robert McCabe has been involved in commercial
More informationHow To Order A Direct Flow Air Cleaner
Reduced Volume - Improved Performance - Flexible Packaging The patented Direct Flow technology provides the flexibility to optimize the air system performance to size ratio, meeting the demands of today
More informationA. Air-Conditioning and Refrigeration Institute: 1. ARI 850 - Commercial and Industrial Air Filter Equipment.
SECTION 23 40 00 - HVAC AIR CLEANING DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Activated carbon filters. 2. Extended surface rigid air filter with synthetic media. 3. Disposable panel
More informationHVAC Design Requirements
Maintenance of HVAC HVAC Design Requirements Air Flow Diagram แบบ Recirculation Air Flow Diagram แบบ Once Through Definition Of Conditions As built At rest In operation air air air Maintenance GMP Requirements
More informationHEATER, AIR CONDITIONING AND VENTILATION
55-1 GROUP 55 HEATER, AIR CONDITIONING AND VENTILATION CONTENTS GENERAL DESCRIPTION 55-2 HEATER AND AIR CONDITIONING SYSTEM 55-4 HEATER CONTROL 55-6 A/C-ECU 55-7 A/C COMPRESSOR 55-9 CONDENSER 55-9 DUCT
More informationInnovent LASER Packaged Fresh Air Conditioning Units
LASER Latent And Sensible Energy Reduction Latent And Sensible Energy Reduction For Outside Air Innovent LASER Packaged Fresh Air Conditioning Units Innovent LASER units provide both sensible and latent
More informationChapter 12 Industrial Ventilation
Chapter 1 Industrial Ventilation Introduction Industrial Ventilation is an important method for reducing employee exposures to airborne contaminants. Ventilation is used to reduce or remove contaminates
More informationGuide to in situ leak testing of HEPA filter configurations that cannot be conventionally scan tested
DOP Solutions Technical Document: Guide to in situ leak testing of HEPA filter configurations that cannot be conventionally scan tested Issue 1: Prepared by Neil Stephenson and Tim Triggs and edited by
More informationElement D Services Heating, Ventilating, and Air Conditioning
PART 1 - GENERAL 1.01 OVERVIEW A. This section supplements Design Guideline Element D3041 on air handling distribution with specific criteria for projects involving design of a Data Center spaces B. Refer
More informationVentilation Solutions Radon Mitigation
Ventilation Solutions Radon Mitigation 2 Radon Mitigation Radon is a health hazard with a simple solution Radon is everywhere! You can t see radon and you can t smell it or taste it, but it may be a problem
More informationIEQ Management Plan. Denver Museum of Nature and Science ECF Addition
IEQ Management Plan GH Phipps Construction Companies 5995 Greenwood Plaza Blvd., Suite 100 Greenwood Village, Colorado 80111-4710 303.571.5377 PHONE www.ghphipps.com Denver Museum of Nature and Science
More informationVentilation Standard For Health Care Facilities
The following article was published in ASHRAE Journal, October 2008. Copyright 2008 American Society of Heating, Refrigerating and Air- Conditioning Engineers, Inc. It is presented for educational purposes
More informationIndustrial Ventilation Design Guidebook Chapter 10 LOCAL VENTILATION
Industrial Ventilation Design Guidebook Chapter 10 LOCAL VENTILATION LARS OLANDER, LORRAINE CONROY, ILPO KULMALA, RICHARD P. GARRISON, MICHAEL ELLENBECKER, BERNHARD BIEGERT, BERNARD FLETCHER, HOWARD D.
More informationCommercial Coil Cleaning:
18 Commercial Coil Cleaning: by Barry Harris, PH.D., ASCS 1, Lindell F. Killian, ASCS 2, and Nicolaus P. Neumann, P.E. 3 A Case History Facility managers and HVAC engineering supervisors have limited budgets
More informationToday, healthcare facilities must be prepared to face
Alternate Methods for USING GERMICIDAL UV-C Disinfection Lamps TO SUPPLEMENT HEPA Filtration By Dave Shagott Today, healthcare facilities must be prepared to face potential large-scale threats from chemical,
More informationECHO System for Basements
ECHO System for Basements Homeowners looking for more space are all too familiar with the cold, damp and dingy basement. Now, the Enclosure Conditioned Housing (ECHO) System TM, winner of the Ottawa-Carleton
More informationAppendix A: SOP of Information Required from Tyson and Information for the Producer
Appendix A Page 1 of 1 Appendix A: SOP of Information Required from Tyson and Information for the Producer Measurements To Be Taken 1. Inside and outside temperature and relative humidity. 2. Fan status
More informationProcedures for the Effective Use of Biological Safety Cabinets
Procedures for the Effective Use of Biological Safety Cabinets APPROVAL DATE BY BIOHAZARDS SUBCOMMITTEE: August 10, 2012 SUPERSEDES: March 1, 2012 This corporate guideline/procedure is intended as a minimum
More informationDownflo workstation DuSt ColleCtorS
Downflo WorkStation Dust Collectors Outperforms All Other Collectors Downflo WorkStations (DWS) fit anywhere on the plant floor and apply NO restrictions to worker movements or visibility. The full line
More information2014 British Columbia Building Code Changes
District of Houston 250-845-2238 2014 British Columbia Building Code Changes A District of Houston interpretation of the 2014 Building Code Changes for 9.36 & 9.32 The following changes reflect the most
More informationHEPA FILTER DEFECTS ARE COMMON
HEPA FILTER DEFECTS ARE COMMON Kenneth F. Cherry 1 and Kenneth A. Smigielski 2 1 NCEC Inc. 2 First Solar LLC. ABSTRACT HEPA filters (High Efficiency Particulate Air) filters are claimed by vendors to have
More informationHeating, Ventilation, Air Conditioning and Refrigeration (HVACR)
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) I. Demonstrate safety skills in typical HVACR work situations to NATE Core Installer Knowledge Areas for Technician Excellence for Safety
More informationRPV - RP - RA air handling units
APPLICATIONS Heating, ventilation, cooling >> FACTORIES >> WAREHOUSES >> HALLS >> DISTRIBUTION CENTRES >> COMMERCIAL PREMISES >> PLACES OF WORSHIP RPV - RP - RA air handling units www.reznor.eu RPV - RP
More informationAsbestos in the Workplace: A Guide to Removal of Friable Asbestos Containing Material
Asbestos in the Workplace: A Guide to Removal of Friable Asbestos Containing Material Revised November 21, 2013 Application Code of Practice Where asbestos is present or believed to be present in a workplace
More informationHow To Design A Gas Dryer
Non Domestic Laundry Gas Appliance Installation Code of Practice Introduction This code of practice has been produced with the assistance of all Companies within the OPL sector of SLEAT because of the
More informationDehumidification Frequently Asked Questions
Dehumidification Basics Why do you want to keep indoor Rh between 30-60%? ASHRAE recommends keeping the relative humidity in a home between 30-60% to limit the effects of many unwanted conditions and harmful
More informationA Prototype Alternative Ventilation System for Retrofit, Rehab and Renovation of Rural Alaska Houses
A Prototype Alternative Ventilation System for Retrofit, Rehab and Renovation of Rural Alaska Houses Robert L Crosby Jr, Biorealis Systems, Inc. Abstract: Bristol Bay Housing Authority (BBHA) currently
More informationSPECIAL APPLICATIONS
Page 1 SPECIAL APPLICATIONS The protection of microelectronics clean rooms using aspirating smoke detection systems requires special consideration. The physical configuration of the room(s) and the direction
More informationLow Cost. Lower Energy Costs. Higher Efficiency.
HI-E DRY dehumidifiers remove two to three times more water per kilowatt hour of electricity than conventional dehumidifiers. Low Cost. Lower Energy Costs. Higher Efficiency. Therma-Stor designed an efficient,
More informationOwner's Manual Air-Purifier MK-B1000 Air Cleaning Expert 110V Model
Owner's Manual Air-Purifier MK-B1000 Air Cleaning Expert 110V Model Quick Reference Table of Contents How the Air-Purifier MK-B1000 works (pg.2) Getting to Know Your New Air-Purifier MK-B1000 (pg.2).location
More informationControlling Condensation On CWP Insulation BY ED LIGHT, MEMBER ASHRAE; JAMES BAILEY, P.E., MEMBER ASHRAE; AND ROGER GAY
This article was published in ASHRAE Journal, Decemeber 2014. Copyright 2014 ASHRAE. Posted at www.ashrae.org. This article may not be copied and/or distributed electronically or in paper form without
More informationAnswers to Your Questions from the Webinar
2008 Desert Aire and USA Swimming. Used by permission. Desert Aire & USA Swimming - Aquatics Webinar - Answers to Your Questions Answers to Your Questions from the Webinar Thank you for your interest in
More informationAir Conditioning. The opportunity for energy efficiency. Low cost actions to reduce energy usage now
Fact Sheet #6 Air Conditioning In this fact sheet you will discover: The opportunity for energy efficiency How air conditioning works Low cost actions to reduce energy usage now Investments to reduce costs
More informationHVAC Code Requirements
one and two family dwellings? Answer: SECTION 2001: GENERAL 2001.1 Air supply. Fuel-burning equipment shall be provided with a supply of air for fuel combustion, draft hood dilution and ventilation of
More informationHVAC Systems and Indoor Air Quality. Douglas K. Spratt, M.Sc., P.Eng.
HVAC Systems and Indoor Air Quality Douglas K. Spratt, M.Sc., P.Eng. The 5 Senses Architecture Electrical Structural Mechanical Hearing Seeing Smelling Feeling Tasting HVAC Systems are Dynamic Heat Gains
More informationG U I D E L CERTIFICATION EDUCATION TRAINING. Procurement Guideline. National Air Filtration Association Recommended Practice
G U National Air Filtration Association Recommended Practice I D E L I N E Procurement Guideline TRAINING EDUCATION CERTIFICATION HVAC Air Filter Purchasing Specification Guideline 1.0 Purpose To provide
More informationAIRROLLAIR COMPRESSORS 15-20 - 25-30 - 40E
AIRROLLAIR COMPRESSORS 15-20 - 25-30 - 40E ROLLAIR 15-40E: INCREASED FLEXIBILITY IN AN EXTENDED RANGE Worthington Creyssensac cares for future generations and is an ISO 14000 certified manufacturing company
More informationAustralian/New Zealand Standard
Australian/New Zealand Standard The use of ventilation and air conditioning in buildings - Part 1: Fire and smoke control in buildings UPDATED AS/NZS 1668.1:2015 What is the scope of this Standard? The
More informationOn-Demand Ventilation Energy Saving in Industrial Applications
On-Demand Ventilation Energy Saving in Industrial Applications Ales Litomisky, Ecogate, Inc. ABSTRACT The purpose of this paper is to describe innovative on-demand industrial ventilation. These on-demand
More informationAutomobile Air Conditioning Primer
Automobile Air Conditioning Primer An air conditioner is basically a refrigerator without the insulated box. It uses the evaporation of a refrigerant, like Freon, to provide cooling. The mechanics of the
More informationCooling Capacity CFM range @.5 in. w.c. (125 Pa)
N8MXL Product Specifications 80% ECM Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out sensors standard Category I venting Blocked vent switch 24 VAC humidifier terminal Electronic air
More informationEvaluating the Field Performance of Windows and Curtain Walls of Large Buildings
Best2 Airtightness of Buildings Session WB6-2 Evaluating the Field Performance of Windows and Curtain Walls of Large Buildings Mario D. Gonçalves, Patenaude-Trempe and Robert Jutras, Air-Ins Introduction
More informationVariTrane Duct Designer An in depth look...
VariTrane Duct Designer An in depth look... Introduction The VariTrane Duct Designer duct design program was written to help optimize design while obtaining a minimum pressure system. The program is based
More informationNewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS PARTS LIST Front Back FIG.5 FIG.6 1. Control panel 2. Carrying handle 3. Water tank 4. Casters
More informationCooling Capacity CFM range @.5 in. w.c. (125 Pa)
96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL 96% AFUE, all models all positions Xtra SEER ECM blower motor Supports two stage cooling units Dehumidification feature in cooling California NOx
More informationPlumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling
Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling February 2001 contents General Information 3 Inspection 4 New Drain and Vent Installations
More informationVentilation Solutions Kitchens. fantech
Ventilation Solutions Kitchens 2 Kitchens Today s kitchens have become much more than a place for cooking and food preparation. The kitchen is the heart of the home. It s the center of activity for the
More informationBring the fresh in. Dedicated Outside Air Systems
Bring the fresh in. Dedicated Outside Air Systems The inside story on outside air. On average, we breathe in 3,400 gallons of air each day. Ambient indoor air pollution is a major problem, affecting health
More informationWORKSHEET FOR RESIDENTIAL AIR SYSTEM DESIGN page 1
WORKSHEET FOR RESIDENTIAL AIR SYSTEM DESIGN page 1 Wallet card photocopy Inspection Authority: Signature: Date: / / Submitted For: ( Owner ) Name Address City Prov Postal code Phone ( ) Fax ( ) Designer/Signature:
More informationCONTROL METHODS. There are five ways to control the release of asbestos fibers:
Control Methods CONTROL METHODS When asbestos containing materials are found in a building, the owner must decide which method or methods will be used to deal with the asbestos. The decision will be based
More informationDATA CENTERS. Protect Your Best in Class Technology With Ours CLEAN AIR SOLUTIONS
DATA CENTERS Protect Your Best in Class Technology With Ours CLEAN AIR SOLUTIONS COSTLY FAN ENERGY REDUCED BY CAMFIL PREMIUM PRODUCTS = COST SAVINGS Power Usage Effectiveness (PUE) is an important metric
More informationWalnut Drying Design and Operation. Selecting Dryer Type. Tray Drying Before 1920. Don Osias Jim Thompson
Walnut Drying Design and Operation Don Osias Jim Thompson Selecting Dryer Type Tray Drying Before 1920 1 Stack Dryer Energy efficient High capital cost Pothole For small lots High labor cost Hopper-bottom
More informationBoth health-care facility classification and area classification, as per CSA, determine the design requirements.
HEATING, VENTILATION AND AIR-CONDITIONING SYSTEM (HVAC) Class 1 Facility: General Anesthesia Heating, ventilation and air-conditioning system standards are a primary infection prevention and control strategy
More informationIPACK2005-73273 DISTRIBUTED LEAKAGE FLOW IN RAISED-FLOOR DATA CENTERS
Proceedings of IPACK5 ASME InterPACK '5 July 17-, San Francisco, California, USA IPACK5-7373 DISTRIBUTED LEAKAGE FLOW IN RAISED-FLOOR DATA CENTERS Amir Radmehr Innovative Research, Inc. Plymouth, MN, USA
More informationF9MXE. Product Specifications
96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL 96% AFUE, all models all positions Select models earn the ENERGY STAR (See below, indicated with check mark.) Xtra SEER ECM blower motor Supports
More informationEnvironmental Monitoring
Chapter 10 Environmental Monitoring By the end of this chapter, you will be able to: l List the types of environmental testing l Name three types of checks that are carried out to ensure the isolator is
More informationEssam E. Khalil khalile1@asme.org
AIR-CONDITIONING SYSTEMS DEVELOPMENTS IN HOSPITALS: COMFORT, AIR QUALITY, AND ENERGY UTILIZATION Essam E. Khalil khalile1@asme.org PROFESSOR OF MECHANICAL ENGINEERING, CAIRO UNIVERSITY, EGYPT Abstract
More informationUsing Portable Spot Air Conditioners in Industrial Applications
Using Portable Spot Air Conditioners in Industrial Applications Cooling People, Processes and Equipment In today s highly competitive manufacturing sector, companies are constantly looking for new ways
More informationREMODELING DAIRY BARNS FOR DAIRY BEEF HOUSING
REMODELING DAIRY BARNS FOR DAIRY BEEF HOUSING David W. Kammel Biological Systems Engineering department 460 Henry mall Madison, WI53706 608 262-9776 dwkammel@wisc.edu Introduction There are a large number
More informationPlumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling
PLANNING, PROPERTY AND DEVELOPMENT DEPARTMENT Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling October 2014 contents General Information
More informationIEQ-15 Air Distribution System
AIM OF CREDIT To encourage and recognise the design and maintenance of air distribution systems that minimise the risk of particulate and microbial contamination to the internal air supply. CREDIT CRITERIA
More informationEnergy Efficiency HOSPITALITY. www.energia.ie
Energy Efficiency HOSPITALITY www.energia.ie Your chance to reduce your business energy usage by as much as 20%! 20% is a significant figure and reducing your energy bill by this amount could make a real
More informationMedical Air Systems: Scroll
GENERAL The Chemetron skid mount scroll medical air system is designed to provide medical breathing air for hospital and medical institutions. This system meets NFPA 99 requirements for Level 1 breathing
More informationPreparing the Work Area
Preparing the Work Area Work Area Preparation Objectives of Work Area Prep Sequence and Methods for Prep Engineering Controls: Negative Pressure Requirements, Equipment and Set-up Purpose of Area Prep
More informationVentilation Solutions Fresh Air Solutions for Ductless Heating & Cooling. fantech
Ventilation Solutions Fresh Air Solutions for Ductless Heating & Cooling 2 Ductless Ventilation & Fresh Air Solutions We can fill your home with healthy, fresh air Indoor Air Pollution is real, and it
More informationAcoustical Design Guidelines for HVAC Systems in Schools
Acoustical Design Guidelines for HVAC Systems in Schools Seminar 9, ASHRAE Summer Meeting Albuquerque, New Mexico Sponsor: TC 2.6 Sound and Vibration Robert M. Lilkendey Associate Principal Consultant
More informationBoth health-care facility classification and area classification, as per CSA, determine the design requirements.
HEATING, VENTILATION AND AIR-CONDITIONING SYSTEM (HVAC) Class 3 Facility: Local Anesthesia Heating, ventilation and air-conditioning system standards are a primary infection prevention and control strategy
More informationPI s Name Date Bldg./Rm# CDC Biosafety Level 3 (BSL-3)
PI s Name Date Bldg./Rm# CDC Biosafety Level 3 (BSL-3) Yes No 1. Is access to the laboratory limited or restricted at the discretion of the laboratory director when experiments are in progress? Yes No
More informationCamfil Farr Technical Services Bulletin
Camfil Farr Technical Services Bulletin ASHRAE Testing for HVAC Air Filtration A Review of Standards 52.1-1992 & 52.2-1999 The American Society of Heating, Refrigeration, and Air Conditioning Engineers
More informationDehumidifier Users manual. For Models: DH45S DH65S
Dehumidifier Users manual For Models: DH45S DH65S 950-0062-revD Jan. 9 2007 FORWARD The appearance of the units that you purchase might be slightly different from the ones described in the Manual, but
More informationUSER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting
More informationLaboratory Performance Testing of Residential Window Mounted Air Conditioners
Laboratory Performance Testing of Residential Window Mounted Air Conditioners Jon Winkler Chuck Booten Dane Christensen Jeff Tomerlin April 29, 2012 NREL is a national laboratory of the U.S. Department
More informationPhoenix Process Engineering, Inc. Project Experience Helping Clients Achieve MACT Compliance
Phoenix Process Engineering, Inc. Project Experience Helping Clients Achieve MACT Compliance The Boiler MACT, 40 CFR 63, Subpart DDDDD, was vacated in 2007 by the U.S Court of Appeals and the 2004 rule
More informationLiquid Cooling Solutions for DATA CENTERS - R.M.IYENGAR BLUESTAR LIMITED.
Liquid Cooling Solutions for DATA CENTERS - R.M.IYENGAR BLUESTAR LIMITED. Presentation Goals & Outline Power Density Where we have been- where we are now - where we are going Limitations of Air Cooling
More informationPOLICY BULLETIN Tecumseh Compressor Company Compressor Group
to Bulk Milk Coolers and Other System Page 1 of 5 Overall reliability can be enhanced if there exists a complete understanding of the features, system design, installation requirements, processing, charging
More informationThere are several types of air cleaning devices available, each designed to remove certain types of pollutants.
Please Note: EPA neither certifies nor recommends particular brands of home air cleaning devices. While some home air cleaning devices may be useful in some circumstances, EPA makes no broad endorsement
More informationMODEL: DV72. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual. Configuration Left Hand Right Hand
9041381- Issue 6 4/11 MODEL: DV72 Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual Commissioning Data: to be completed by the installer Date of installation: Configuration
More informationCooling Capacity CFM range @.5 in. w.c. (125 Pa)
96% AFUE, Two Stage ECM Gas Furnace EASIER TO SELL 96% AFUE, all models, all positions Two stage heating operation Xtra SEER ECM blower motor Supports two stage cooling units Dehumidification feature in
More informationLiabilities of Vented Crawl Spaces, Their Impacts on Indoor Air Quality in Southeastern U.S. Homes and One Intervention Strategy
Liabilities of Vented Crawl Spaces, Their Impacts on Indoor Air Quality in Southeastern U.S. Homes and One Intervention Strategy Jonathan Coulter 1 ABSTRACT This paper documents the influences vented crawl
More informationDiagnostics for Mobile Homes: HVAC
Diagnostics for Mobile Homes: HVAC Adam Harris NYSWDA Wade Thompson - IWTC Objectives Identify different types of HVAC used in mobile homes Provide an overview of duct systems Demonstrate various tests
More informationBPI Air Conditioning & Heat Pump Professional Training Sample Slides ( ) Agenda
BPI Air Conditioning & Heat Pump Professional Training Sample Slides ( ) Photo of scott at AC with guages 1 Agenda Day I Refrigerants Introductions Verifying Charge Super Heat Paperwork & Sign-In Subcooling
More informationTechnical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC
Technical Concept Filter Fan Unit COMPACT Type COMPACT AC Type COMPACT EC Ultra Filter Fan Unit COMPACT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide
More informationMould Mould A Basic Guide
Mould A Basic Guide Summary Mould is a fact of life. Moulds will grow practically everywhere people live and work. Mould is recognized as an occupational hazard for indoor workers as well as outdoor workers
More informationSECTION 15936 AIR INLETS AND OUTLETS
SECTION 15936 AIR INLETS AND OUTLETS PART 1 - GENERAL 1.01 SUMMARY A. Section Includes: 1. Diffusers. 2. Registers. 3. Grilles. 4. Louvers. 5. Lowered Penthouses. 6. Gravity Roof Hoods. 7. Gravity Roof
More informationBuilding Performance Solutions HVAC Design Guide, 2007
Building Performance Solutions HVAC Design Guide, 2007 HVAC sizing, system design, layout, and installation shall be sized according to (Air Conditioning Contractor of America), ACCA manual J8, 8 th edition,
More informationElectrostatic or Electronic: Know the Facts By Robert P. Scaringe, P.E., Ph.D., ---President of Mainstream Engineering
Electrostatic or Electronic: Know the Facts By Robert P. Scaringe, P.E., Ph.D., ---President of Mainstream Engineering HVAC system air filter upgrades are one way contractors can simultaneously increase
More informationASTACEA4 Inspect complex/central air conditioning systems
Overview This Unit covers the competences required to inspect complex/central air conditioning systems as defined by the CIBSE TM 44 Figure 1.1: Summary of system types and their component parts. The air
More informationLIFE SAFETY UPDATE. FULL SPRINKLERING OF ALL NURSING FACILITIES ADDITIONAL CLARIFICATIONS Prepared by Eric Rosenbaum, P.E. Hughes Associates, Inc.
LIFE SAFETY UPDATE FULL SPRINKLERING OF ALL NURSING FACILITIES ADDITIONAL CLARIFICATIONS Prepared by Eric Rosenbaum, P.E. Hughes Associates, Inc. The purpose of this update is as follows: Remind all state
More information