Major Cardiac Imaging Advances in Last 5 Years: Nuclear (Imaging Technology) Advances. Youngho Seo, PhD

Size: px
Start display at page:

Download "Major Cardiac Imaging Advances in Last 5 Years: Nuclear (Imaging Technology) Advances. Youngho Seo, PhD"

Transcription

1 Major Cardiac Imaging Advances in Last 5 Years: Nuclear (Imaging Technology) Advances Youngho Seo, PhD

2 Technical Advances in Major Cardiac Imaging Areas using SPECT or PET Information we (can) get from nuclear imaging techniques Myocardial perfusion nuclear myocardial perfusion imaging Ejection fraction radionuclide ventriculography or gated MPI Myocardial viability radionuclide viability study (e.g., FDG-PET) Sympathetic innervation radioactive norepinephrine analogue (e.g., mibg) Myocardial blood flow Dynamic PET (and SPECT) Coronary flow reserve Stress dynamic PET (and SPECT) Research areas to advance nuclear cardiac imaging Improve quantitation of the above parameters accuracy, ease, dose reduction, speed of acquisition, etc. Dedicated nuclear cardiac imaging Small footprint, mobile, compact, etc. (not that much going on lately) Dedicated cardiac SPECT collimators (improving existing systems) New general-purpose scanner (e.g., PET/MRI) New radiopharmaceuticals Better flow agent (improved PET (e.g., F-18) and SPECT perfusion agents) Better norepinephrine analogue imaging agent (e.g., mfbg or other analogues) New applications Coronary flow reserve (by PET and SPECT), myocardial efficiency, inflammation, etc.

3 General-Purpose SPECT(/CT) Systems for Cardiac Imaging Newer scanner technologies have been introduced to improve both qualitative and quantitative SPECT imaging Quantification - Siemens xspect (2013), GE Q.Metrix (2014) provides measurements in Bq/ml (activity concentration) PET-like quantitative accuracy Improve resolution by improving reconstruction algorithm - Siemens IQ-SPECT (2011), UltraSPECT Wide-Beam reconstruction (correcting PSF variability, 2006) Improve resolution and sensitivity by improving collimator geometry Siemens IQ- SPECT (2011) New detector technology (e.g., CZT) for general-purpose SPECT GE Discovery NM/CT 670 CZT (2016)

4 Examples: Confocal Collimators & PSF Model Recon

5 Dedicated Cardiac SPECT Systems D-SPECT (Spectrum Dynamics) introduced in 2005 (a while ago) GE NM 530c and NM/CT 570c introduced in 2009 (also a while ago) Both systems use new solid-state detectors, CdZnTe (CZT) instead of NaI(Tl) crystals. Evidence of the advantage of doing scans with dedicated scanners is coming more lately. Erlandsson K, et al. Phys Med Biol. 2009;54:2635

6 One of Benefits of Using Dedicated Cardiac SPECT Dynamic Cardiac SPECT data acquisition is simpler than rotational SPECT. Allowing further analysis of the data when SPECT data are acquired dynamically. Ben-Haim S, et al. J Nucl Med. 2013;54:873

7 General-Purpose PET(/CT) Systems for Cardiac Imaging Not that much specialized hardware improvement for cardiac applications But, technologies like time-of-flight (TOF), PSF model in reconstruction, large axial FOV (better sensitivity and better/easier whole-heart coverage) all contribute to improved cardiac PET imaging. More efforts for new PET radiotracer development The workhorse is Rb-82 (generator produced). 13 N-NH 3 is better (shorter positron range), but less used because of logistics (onsite cyclotron requirement) and poorer production control. The biggest latest effort is F-18 labeled PET myocardial perfusion imaging agent development High throughput, best-possible radionuclide (F-18) for PET imaging (shortest positron range) First Phase 3 trial of 18 F-flurpiridaz (binding to mitochondrial complex 1, MC-1) did not meet the expected end points, flurpiridaz F 18 far exceeded SPECT for sensitivity but did not meet the non-inferiority threshold for specificity (May 4, 2015) Press Release from Lantheus The second Phase 3 study with different end points has been designed (according to Lantheus). However, this trial has not started yet though.

8 18 F-flurpiridaz PET MPI Berman DS, et al. J Am Coll Cardiol. 2013;61:469

9 Integrated PET-MRI for Cardiac Imaging Cardiac imaging applications that benefit from both PET and MRI Doing both at the same time relieve the logistical challenges at the minimum. Must make sure that the imaging capabilities for both PET and CMR are not compromised. PET Insert PET Insert Siemens mmr (2011) GE SIGNA PET/MR (2015), Image Courtesy of GE Healthcare

10 Effect of TOF-PET-MRI for Cardiac Imaging A C B D A) Non ECG gated, time-of-flight reconstruction. B) Non ECG gated, non time-of-flight reconstruction C) End diastole, time-of-flight reconstruction D) End diastole, non time-of-flight reconstruction E) 3D Cine MRI at systole F) 3D Cine MRI at diastole. E F Data courtesy of UCSF (K. Ordovas, J. Liu, Y. Seo)

11 Emerging Radiopharmaceuticals for Nuclear Cardiac Imaging 18 F-labeled perfusion imaging agent for PET e.g., 18 F-flurpiridaz 18 F-labeled sympathetic innervation imaging agent for PET e.g., MFBG (meta-[ 18 F]fluorobenzylguanidine), MFPBG (meta-(3- [ 18 F]fluoropropyl)benzylguanidine), LMI1195 (N-[3-Bromo-4-(3-[18F]fluoro-propoxy)-benzyl]- guanidine) Investigation for cardiac applications is either underway or considered Better flow-extracting 99m Tc-labeled perfusion imaging agent for SPECT 99m Tc-teboroxime could be revived since there are dedicated cardiac SPECT scanners that allow fast imaging suitable for fast washin and washout kinetics of the tracer 123 I-labeled rotenone analogues have been pursued in this direction Imaging fatty acid analogue for fatty acid metabolism (important energy for healthy myocardial activity) 123 I-BMIPP for SPECT 18 F-FTHA for PET

12 LMI1195 in Rats, Rabbits, and Human Subjects Yu M, et al. Circ Cardiovasc Imaging. 2011;4:435

13 CMICE-013 ( 123 I-labeled rotenone derivative) Representative CMICE-013 images of porcine heart. R. Glenn Wells et al. J Nucl Med. 2015;56:764

14 18 F-FDG (glucose), 18 F-FDHROL (rotenol), 18 F-FTHA (fatty acid) in Failing Heart of Rat (Top) PET images corresponding to all electrocardiogram bins summed. (Bottom) PET images corresponding to only diastolic electrocardiogram bins summed. (A) 18 F-FDG images of SHR show almost no liver uptake. (B) 18 F- FDHROL images of SHR show substantial liver uptake. (C) 18 F-FTHA images of SHR again show substantial liver uptake. Andrew M. Hernandez et al. J Nucl Med. 2013;54:1938

15 New(er) Nuclear Cardiac Imaging Applications Dynamic Cardiac SPECT Imaging Analogous to dynamic cardiac PET imaging Allows SPECT to be used for myocardial blood flow and coronary flow reserve measurements Myocardial Inflammation Imaging (e.g., myocarditis, sarcoidosis, etc.) FDG, choline, somatostatin receptor Myocardial Efficiency Imaging Oxygen consumption, glucose utilization, fatty acid utilization Provided ways to assess the work output (that can be measured by PET only, with MRI strain measurement, etc.)

16 Dynamic Cardiac SPECT Imaging Data courtesy of UCSF. Shrestha U, et al. J Nucl Cardiol (Epub ahead of print)

17 MBF and CFR in Orthotopic Heart Transplant LAD 1. basal anterior 2. basal anteroseptal 7. mid anterior 8. mid anteroseptal 13. apical anterior 14. apical septal 17. apex RCA 3. basal inferoseptal 4. basal inferior 9. mid inferoseptal 10. mid inferior 15. apical inferior LCX 5. basal inferolateral 6. basal anterolateral 11. mid inferolateral 12. mid anterolateral 16. apical lateral GLOBAL TOTAL LAD 1. basal anterior 2. basal anteroseptal 7. mid anterior 8. mid anteroseptal 13. apical anterior 14. apical septal 17. apex RCA 3. basal inferoseptal 4. basal inferior 9. mid inferoseptal 10. mid inferior 15. apical inferior LCX 5. basal inferolateral 6. basal anterolateral 11. mid inferolateral 12. mid anterolateral 16. apical lateral GLOBAL TOTAL Data courtesy of UCSF. Shrestha U, et al. J Nucl Cardiol. In Press

18 Cardiac Efficiency Imaging Using PET/MRI Data courtesy of UCSF (G. Gullberg, U. Shrestha, Y. Seo)

19 Summary Improved quantitation/quantification techniques accuracy, ease, dose reduction, speed of acquisition, etc. Dedicated nuclear cardiac imaging scanners Small footprint, mobile, compact, etc. (but not that much going on lately) Improved general-purpose scanners (e.g., SPECT/CT, PET/CT, PET/MRI) tuned for cardiac applications (improved cardiac SPECT reconstruction, dedicated cardiac SPECT collimators, MRI combination, etc.) New radiopharmaceuticals Better flow agent (improved PET and SPECT perfusion agents under study) Better sympathetic neuronal activity imaging agents (e.g., MFBG, MFPBG, LMI1195, etc.) New/revisited applications Utility of coronary flow reserve (by PET and SPECT), inflammation, myocardial efficiency

Rb 82 Cardiac PET Scanning Protocols and Dosimetry. Deborah Tout Nuclear Medicine Department Central Manchester University Hospitals

Rb 82 Cardiac PET Scanning Protocols and Dosimetry. Deborah Tout Nuclear Medicine Department Central Manchester University Hospitals Rb 82 Cardiac PET Scanning Protocols and Dosimetry Deborah Tout Nuclear Medicine Department Central Manchester University Hospitals Overview Rb 82 myocardial perfusion imaging protocols Acquisition Reconstruction

More information

Objectives. Cardiac Substrate Metabolism. 2004 SNM Mid-Winter Educational Symposium

Objectives. Cardiac Substrate Metabolism. 2004 SNM Mid-Winter Educational Symposium Myocardial Viability Imaging With PET Marcelo F. Di Carli,, MD Brigham and Women s Hospital Harvard Medical School Boston, MA Conflict of Interest: : No Relations to disclose To review: Basic principles

More information

4DM Key Feature List. An overview of new and enhanced features in the current and previous versions of 4DM.

4DM Key Feature List. An overview of new and enhanced features in the current and previous versions of 4DM. 4DM Key Feature List An overview of new and enhanced features in the current and previous versions of 4DM. v2016 4DM Administration PDF Viewer Screen EKG Viewer Screen Merge Patients SPECT-CFR Quantification

More information

MYOCARDIAL PERFUSION COMPUTED TOMOGRAPHY PhD course in Medical Imaging. Anne Günther Department of Radiology OUS Rikshospitalet

MYOCARDIAL PERFUSION COMPUTED TOMOGRAPHY PhD course in Medical Imaging. Anne Günther Department of Radiology OUS Rikshospitalet MYOCARDIAL PERFUSION COMPUTED TOMOGRAPHY PhD course in Medical Imaging Anne Günther Department of Radiology OUS Rikshospitalet CORONARY CT ANGIOGRAPHY (CTA) Accurate method in the assessment of possible

More information

PET and PET/CT in Clinical Trials

PET and PET/CT in Clinical Trials PET and PET/CT in Clinical Trials Nathan C. Hall, M.D., Ph.D. The Ohio State University Medical Center CALGB Imaging Core Lab CALGB Imaging Committee Outline Introduction to PET Positron Emitter Physics

More information

CPT CODE PROCEDURE DESCRIPTION. CT Scans 70450 CT HEAD/BRAIN W/O CONTRAST 70460 CT HEAD/BRAIN W/ CONTRAST 70470 CT HEAD/BRAIN W/O & W/ CONTRAST

CPT CODE PROCEDURE DESCRIPTION. CT Scans 70450 CT HEAD/BRAIN W/O CONTRAST 70460 CT HEAD/BRAIN W/ CONTRAST 70470 CT HEAD/BRAIN W/O & W/ CONTRAST CPT CODE PROCEDURE DESCRIPTION CT Scans 70450 CT HEAD/BRAIN W/O CONTRAST 70460 CT HEAD/BRAIN W/ CONTRAST 70470 CT HEAD/BRAIN W/O & W/ CONTRAST 70480 CT ORBIT W/O CONTRAST 70481 CT ORBIT W/ CONTRAST 70482

More information

BEYOND 18 F-FDG: INTRODUCTION TO NEW RADIOPHARMACEUTICALS

BEYOND 18 F-FDG: INTRODUCTION TO NEW RADIOPHARMACEUTICALS BEYOND F-FDG: INTRODUCTION TO NEW RADIOPHARMACEUTICALS Asti Mattia Nuclear Medicine Department Santa Maria Nuova Hospital, Reggio Emilia, Italy SUMMARY: F-Labelled Choline analogues. Comparison between

More information

The sympathetic nervous system of the heart plays a key

The sympathetic nervous system of the heart plays a key Effect of Diabetes Mellitus on Sympathetic Neuronal Regeneration Studied in the Model of Transplant Reinnervation Frank M. Bengel 1,3, Peter Ueberfuhr 2, Dominik Schäfer 1, Stephan G. Nekolla 1, Bruno

More information

Part A: Structure and Organization

Part A: Structure and Organization Part A: Structure and Organization Radioactive Materials License NRC (or State) radioactive materials license present Personnel Medical Director Meets Medical Director responsibility requirements Meets

More information

123 Main St NY, New York 12345 ph: (202) 555 5555 fax: (202) 555 5555

123 Main St NY, New York 12345 ph: (202) 555 5555 fax: (202) 555 5555 Patient Name: DOE, JOHN D. Gender: M Date of Study: 4/2/2013 Date of birth: 6/28/1962 Age: 50 Medical Record #: 45869725 Ordering Physician: JANE INTERNIST, MD History: Atypical Angina, Abn ECG, High Cholesterol,

More information

Data. microcat +SPECT

Data. microcat +SPECT Data microcat +SPECT microcat at a Glance Designed to meet the throughput, resolution and image quality requirements of academic and pharmaceutical research, the Siemens microcat sets the standard for

More information

Molecular Imaging: from cell to man

Molecular Imaging: from cell to man Molecular Imaging: from cell to man Torino, 24 November 2011 Advances in PET/SPECT technology for pre-clinical molecular imaging applications Alberto Del Guerra Dipartimento di Fisica "E.Fermi' Università

More information

PET/CT-MRI First clinical experience

PET/CT-MRI First clinical experience 20 th April 2013, Barcelona, Sp PET/CT-MRI First clinical experience Philippe Appenzeller, MD Staff Radiologist and Nuclear Medicine Physician Department Medical Imaging, University Hospital Zurich PET/CT-MR

More information

doi:10.1016/j.jacc.2007.11.013 This information is current as of October 16, 2008

doi:10.1016/j.jacc.2007.11.013 This information is current as of October 16, 2008 Task Force 5: Training in Nuclear Cardiology: Endorsed by the American Society of Nuclear Cardiology Manuel D. Cerqueira, Daniel S. Berman, Marcelo F. Di Carli, Heinrich R. Schelbert, Frans J. Th. Wackers,

More information

Next Generation Small Animal PET Technology

Next Generation Small Animal PET Technology G4 PET/X-ray P R O D U C T N O T E Pre-clinical in vivo Imaging Key Benefits: High performance, ultra-sensitive PET technology designed for pre-clinical imaging 3D PET and X-ray whole body images Purpose

More information

What are some common uses of the procedure?

What are some common uses of the procedure? Scan for mobile link. Cardiac Nuclear Medicine Cardiac nuclear medicine imaging evaluates the heart for coronary artery disease and cardiomyopathy. It also may be used to help determine whether the heart

More information

Myocardial Perfusion Imaging with PET, PET/CT, PET/MRI: Technical Advances and Future Applications

Myocardial Perfusion Imaging with PET, PET/CT, PET/MRI: Technical Advances and Future Applications CHAPTER 22 Myocardial Perfusion Imaging with PET, PET/CT, PET/MRI: Technical Advances and Future Applications Vikas Veeranna, MD and Sharmila Dorbala, MD, MPH Introduction Radionuclide myocardial perfusion

More information

Nuclear PACS: Problems, Solutions

Nuclear PACS: Problems, Solutions Nuclear PACS: Problems, Solutions by Jerold W. Wallis, MD Introduction Reprinted with permission: Wallis JW. Nuclear PACS: Problems, Solutions. Decisions in Imaging Economics. 2004;6;21-25. There is increasing

More information

CARDIOLOGY PROCEDURES REQUIRING PRECERTIFICATION

CARDIOLOGY PROCEDURES REQUIRING PRECERTIFICATION CLINICAL POLICY CARDIOLOGY PROCEDURES REQUIRING PRECERTIFICATION Policy Number: CARDIOLOGY 026.6 T2 Effective Date: May 1, 2015 Table of Contents CONDITIONS OF COVERAGE... COVERAGE RATIONALE... BENEFIT

More information

Purchasing a cardiac CT scanner: What the radiologist needs to know

Purchasing a cardiac CT scanner: What the radiologist needs to know Purchasing a cardiac CT scanner: What the radiologist needs to know Maria Lewis ImPACT St George s Hospital, London maria.lewis@stgeorges.nhs.uk CT scanner development Slice wars 1998 Increased z-coverage

More information

CPT Radiology Codes Requiring Review by AIM Effective 01/01/2016

CPT Radiology Codes Requiring Review by AIM Effective 01/01/2016 CPT Radiology Codes Requiring Review by AIM Effective 01/01/2016 When a service is authorized only one test per group is payable. *Secondary codes or add-on codes do not require preauthorization or separate

More information

Scintigraphic evaluation of myocardial perfusion for the

Scintigraphic evaluation of myocardial perfusion for the Myocardial Perfusion Imaging Protocols: Is There an Ideal Protocol?* Syed Sajid Husain Department of Nuclear Medicine/PET, VA Western New York Healthcare System, Buffalo, New York Is there an ideal myocardial

More information

QUANTITATIVE IMAGING IN MULTICENTER CLINICAL TRIALS: PET

QUANTITATIVE IMAGING IN MULTICENTER CLINICAL TRIALS: PET Centers for Quantitative Imaging Excellence (CQIE) LEARNING MODULE QUANTITATIVE IMAGING IN MULTICENTER CLINICAL TRIALS: PET American College of Radiology Clinical Research Center v.1 Centers for Quantitative

More information

State-of-the-Art Technology in Cardiac CT

State-of-the-Art Technology in Cardiac CT 1 2 Next Step Evolution or Revolution? State-of-the-Art Technology in Cardiac CT Stefan Ulzheimer, PhD Global Director of Collaborations CT Siemens Medical Solutions Major Innovations in CT Head The 80

More information

Computed Tomography, Head Or Brain; Without Contrast Material, Followed By Contrast Material(S) And Further Sections

Computed Tomography, Head Or Brain; Without Contrast Material, Followed By Contrast Material(S) And Further Sections 1199SEIU BENEFIT AND PENSION FUNDS High Tech Diagnostic Radiology and s # 1 70336 Magnetic Resonance (Eg, Proton) Imaging, Temporomandibular Joint(S) 2 70450 Computed Tomography, Head Or Brain; Without

More information

AI CPT Codes. x x. 70336 MRI Magnetic resonance (eg, proton) imaging, temporomandibular joint(s)

AI CPT Codes. x x. 70336 MRI Magnetic resonance (eg, proton) imaging, temporomandibular joint(s) Code Category Description Auth Required Medicaid Medicare 0126T IMT Testing Common carotid intima-media thickness (IMT) study for evaluation of atherosclerotic burden or coronary heart disease risk factor

More information

Diagnostic Imaging Prior Review Code List 3 rd Quarter 2016

Diagnostic Imaging Prior Review Code List 3 rd Quarter 2016 Computerized Tomography (CT) Abdomen 6 Abdomen/Pelvis Combination 101 Service 74150 CT abdomen; w/o 74160 CT abdomen; with 74170 CT abdomen; w/o followed by 74176 Computed tomography, abdomen and pelvis;

More information

Diagnostic and Therapeutic Procedures

Diagnostic and Therapeutic Procedures Diagnostic and Therapeutic Procedures Diagnostic and therapeutic cardiovascular s are central to the evaluation and management of patients with cardiovascular disease. Consistent with the other sections,

More information

A Proposal for an Advanced Cardiovascular Imaging Training Track

A Proposal for an Advanced Cardiovascular Imaging Training Track Journal of the American College of Cardiology Vol. 48, No. 7, 2006 2006 by the American College of Cardiology Foundation ISSN 0735-1097/06/$32.00 Published by Elsevier Inc. doi:10.1016/j.jacc.2006.04.096

More information

Positron Emission Tomography: Principles, Technology, and Recent Developments

Positron Emission Tomography: Principles, Technology, and Recent Developments Nuclear Physics A 752 (2005) 679c 687c Positron Emission Tomography: Principles, Technology, and Recent Developments Sibylle I. Ziegler Nuklearmedizinische Klinik, Klinikum rechts der Isar der Technischen

More information

1 Cerebral metabolic changes in men after chiropractic spinal manipulation for neck pain

1 Cerebral metabolic changes in men after chiropractic spinal manipulation for neck pain 1 Cerebral metabolic changes in men after chiropractic spinal manipulation for neck pain Alternative Therapies Health Medicine Nov-Dec 2011;Vol. 17; No. 6; pp12-7 Tashiro M, Ogura T, Masud M, Watanuki

More information

12 Lead ECGs: Ischemia, Injury & Infarction Part 2

12 Lead ECGs: Ischemia, Injury & Infarction Part 2 12 Lead ECGs: Ischemia, Injury & Infarction Part 2 McHenry Western Lake County EMS Localization: Left Coronary Artery Right Coronary Artery Right Ventricle Septal Wall Anterior Descending Artery Left Main

More information

Flash, Rocking on others Added value in DCM and CRT. C. Parsai Polyclinique des Fleurs France

Flash, Rocking on others Added value in DCM and CRT. C. Parsai Polyclinique des Fleurs France Flash, Rocking on others Added value in DCM and CRT C. Parsai Polyclinique des Fleurs France Cleland JGF et al. (2007) Nat Clin Pract Cardiovasc Med 4: 90 101 Predicting CRT Response Device Related Patient

More information

Riduzione della dose nella SPECT cardiaca : apparecchiature e software

Riduzione della dose nella SPECT cardiaca : apparecchiature e software Riduzione della dose nella SPECT cardiaca : apparecchiature e software Optimization of procedures in Nuclear Cardiology A.Ghilardi Nuclear Medicine Department AO Papa Giovanni XXIII Bergamo Italy Io c

More information

Master s Program in Medical Physics. Physics of Imaging Systems Basic Principles of Computer Tomography (CT) III. Prof. Dr. Lothar Schad.

Master s Program in Medical Physics. Physics of Imaging Systems Basic Principles of Computer Tomography (CT) III. Prof. Dr. Lothar Schad. 1 12/9/2008 Page 1 Master s Program in Medical Physics Physics of Imaging Systems Basic Principles of Computer Tomography (CT) III Chair in Faculty of Medicine Mannheim University of Heidelberg Theodor-Kutzer-Ufer

More information

MYOCARDIAL PET/CT SCAN (FDG tracer)

MYOCARDIAL PET/CT SCAN (FDG tracer) MYOCARDIAL PET/CT SCAN (FDG tracer) Contact information and registration: Meilahti Hospital, Department of Nuclear Medicine Tower Hospital, Haartmaninkatu 4, 00290 Helsinki tel. 09-471 72554 Appointment

More information

University of Texas Medical School at Houston. April 14, 2015

University of Texas Medical School at Houston. April 14, 2015 DEPARTMENT OF HEALTH & HUMAN SERVICES Public Health Service Food and Drug Administration 10903 New Hampshire Avenue Document Control Center WO66-G609 Silver Spring, MD 20993-0002 University of Texas Medical

More information

Family IMAGINGFORSCIENCE. the next generation four modality preclinical imaging platform SPECT/MRI, PET/MRI, SPECT/CT, PET/CT, SPECT/CT/PET

Family IMAGINGFORSCIENCE. the next generation four modality preclinical imaging platform SPECT/MRI, PET/MRI, SPECT/CT, PET/CT, SPECT/CT/PET Family the next generation four modality preclinical imaging platform SPECT/MRI, PET/MRI, SPECT/CT, PET/CT, SPECT/CT/PET IMAGINGFORSCIENCE nanoscan products are No.1 in the following: - achieve the breakthrough

More information

How To Improve Your Ct Image Quality

How To Improve Your Ct Image Quality Translating Protocols Between Scanner Manufacturer and Model Cynthia H. McCollough, PhD, FACR, FAAPM Professor of Radiologic Physics Director, CT Clinical Innovation Center Department of Radiology Mayo

More information

The Danish Cardiovascular Research Academy and Faculty of Health Sciences, University of Copenhagen

The Danish Cardiovascular Research Academy and Faculty of Health Sciences, University of Copenhagen 1 The Danish Cardiovascular Research Academy and Faculty of Health Sciences, University of Copenhagen PhD-course: Cardiovascular Imaging Aim and Content: This course covers important theoretical and practical

More information

PET/CT: Basic Principles, Applications in Oncology

PET/CT: Basic Principles, Applications in Oncology PET/CT: Basic Principles, Applications in Oncology Mabel Djang, HMS III Overview PET Basics and Limitations PET/CT - Advantages and Limitations Applications of PET/CT in oncology Summary 2 Principles of

More information

Effects of Short-term Carvedilol on the Cardiac Sympathetic Activity Assessed by 123 I-MIBG Scintigraphy

Effects of Short-term Carvedilol on the Cardiac Sympathetic Activity Assessed by 123 I-MIBG Scintigraphy Effects of Short-term Carvedilol on the Cardiac Sympathetic Activity Assessed by 123 I-MIBG Scintigraphy Sandra Marina Ribeiro de Miranda 1, Evandro Tinoco Mesquita 1,2, Hans Fernando da Rocha Dohmann

More information

Medical Physics and Radioactivity

Medical Physics and Radioactivity Medical Physics and Radioactivity Radioactivity Unstable nucleus Electromagnetic wave particle Atoms which emit electromagnetic radiation or a particle by the spontaneous transformation of their nucleus

More information

The heart walls and coronary circulation

The heart walls and coronary circulation CHAPTER 1 The heart walls and coronary circulation The heart is located in the central-left part of the thorax (lying on the diaphragm) and is oriented anteriorly, with the apex directed forward, downward,

More information

Quantitative Imaging In Clinical Trials Using PET/CT: Update

Quantitative Imaging In Clinical Trials Using PET/CT: Update Quantitative Imaging In Clinical Trials Using PET/CT: Update Paul Kinahan, Robert Doot Imaging Research Laboratory Department of Radiology University of Washington, Seattle, WA Supported by RSNA Quantitative

More information

Procedure Codes. RadConsult provides real-time decision support for physicians who order high-cost imaging procedures RADIATION THERAPY

Procedure Codes. RadConsult provides real-time decision support for physicians who order high-cost imaging procedures RADIATION THERAPY Procedure Codes 2011 RadConsult provides real-time decision support for physicians who order high-cost imaging procedures RADIATION THERAPY 2D3D Therapeutic radiology treatment planning; simple 77261 Therapeutic

More information

HERC Coverage Guidance Advanced Imaging for Staging of Prostate Cancer Disposition of Public Comments

HERC Coverage Guidance Advanced Imaging for Staging of Prostate Cancer Disposition of Public Comments Table of Contents Commenters... 1 Public Comments... 2 References Provided by Commenters... 6 Commenters Identification Stakeholder A Medical Imaging & Technology Alliance (MITA), Arlington, VA [Submitted

More information

Performance Comparison of Four Commercial GE Discovery PET/CT Scanners: A Monte Carlo Study Using GATE

Performance Comparison of Four Commercial GE Discovery PET/CT Scanners: A Monte Carlo Study Using GATE Performance Comparison of Four Commercial GE Discovery PET/CT Scanners: A Monte Carlo Study Using Parham Geramifar 1,3,4, Mohammad Reza Ay 2,3,4, Mojtaba Shamsaie Zafarghandi 1, George Loudos 5, Arman

More information

Variations in PET/CT Methodology for Oncologic Imaging at U.S. Academic Medical Centers: An Imaging Response Assessment Team Survey

Variations in PET/CT Methodology for Oncologic Imaging at U.S. Academic Medical Centers: An Imaging Response Assessment Team Survey Variations in PET/CT Methodology for Oncologic Imaging at U.S. Academic Medical Centers: An Imaging Response Assessment Team Survey Michael M. Graham 1, Ramsey D. Badawi 2, and Richard L. Wahl 3 1 University

More information

Positron Emission Tomography - For Patients

Positron Emission Tomography - For Patients Positron Emission Tomography - For Patients A physician s written order is required for any PET-CT tests. How should I prepare for my PET-CT? PET-CT is more complicated than most other tests you may be

More information

PET PROS PET Professional Resources and Outreach Source. A summary of the recommendations and practice guidelines of professional groups

PET PROS PET Professional Resources and Outreach Source. A summary of the recommendations and practice guidelines of professional groups PET PROS PET Professional Resources and Outreach Source A summary of the recommendations and practice guidelines of professional groups Background: The SNMMI PET/CT Utilization Task Force (UTF) was formed

More information

A precise, noninvasive technique for the diagnosis of. Cardiac Image Fusion from Stand-Alone SPECT and CT: Clinical Experience

A precise, noninvasive technique for the diagnosis of. Cardiac Image Fusion from Stand-Alone SPECT and CT: Clinical Experience Cardiac Image Fusion from Stand-Alone SPECT and CT: Clinical Experience Oliver Gaemperli 1, Tiziano Schepis 1, Ines Valenta 1, Lars Husmann 2, Hans Scheffel 2, Victor Duerst 1, Franz R. Eberli 1, Thomas

More information

General Nuclear Medicine

General Nuclear Medicine Scan for mobile link. General Nuclear Medicine Nuclear medicine imaging uses small amounts of radioactive materials called radiotracers that are typically injected into the bloodstream, inhaled or swallowed.

More information

Mississippi Medicaid. Provider Reference Guide. For Part 220. Radiology Services

Mississippi Medicaid. Provider Reference Guide. For Part 220. Radiology Services Mississippi Medicaid Provider Reference Guide For Part 220 Radiology Services This is a companion document to the Mississippi Administrative Code Title 23 and must be utilized as a reference only. Table

More information

B I O - T E C H S Y S T E M S, I N C. Market Research in the Health Care Field NEWS RELEASE

B I O - T E C H S Y S T E M S, I N C. Market Research in the Health Care Field NEWS RELEASE B I O - T E C H S Y S T E M S, I N C. Market Research in the Health Care Field NEWS RELEASE 4167 Pinecrest Circle West Las Vegas, Nevada 89121 November 10, 2010 (702) 456-7608 (702) 456-2189 FAX E-Mail:

More information

CPT * Codes Included in AIM Preauthorization Program for 2013 With Grouper Numbers

CPT * Codes Included in AIM Preauthorization Program for 2013 With Grouper Numbers CPT * Codes Included in AIM Preauthorization Program for 2013 With Grouper Numbers Computerized Tomography (CT) CPT Description Abdomen 74150 CT abdomen; w/o contrast 6 74160 CT abdomen; with contrast

More information

Imaging Science. Prof. Dr. rer. nat. Bernd Pichler

Imaging Science. Prof. Dr. rer. nat. Bernd Pichler Imaging Science Prof. Dr. rer. nat. Bernd Pichler Department Radiologie Diagnostic and lnterventional Radiology Prof. Nikolaou Diagnostic and lnterventional Neuroradiology Prof. Ernemann Nuclear Medicine

More information

Journal of the American College of Cardiology Vol. 40, No. 6, 2002 2002 by the American College of Cardiology Foundation ISSN 0735-1097/02/$22.

Journal of the American College of Cardiology Vol. 40, No. 6, 2002 2002 by the American College of Cardiology Foundation ISSN 0735-1097/02/$22. Journal of the American College of Cardiology Vol. 40, No. 6, 2002 2002 by the American College of Cardiology Foundation ISSN 0735-1097/02/$22.00 Published by Elsevier Science Inc. PII S0735-1097(02)02118-6

More information

Now bring the advantages of digital workflow to cardiology

Now bring the advantages of digital workflow to cardiology CARESTREAM Cardiology PACS Now bring the advantages of digital workflow to cardiology The single system advantage Now there s ONE Solution. 2 A large and growing number of health care facilities are benefiting

More information

Global Business Unit Address. Siemens Medical Solutions USA, Inc. 2501 N. Barrington Road Hoffman Estates, IL 60192-5203. Telephone: +1847 304 7700

Global Business Unit Address. Siemens Medical Solutions USA, Inc. 2501 N. Barrington Road Hoffman Estates, IL 60192-5203. Telephone: +1847 304 7700 Trademarks and service marks used in this material are property of Siemens Medical Solutions USA or Siemens AG. All other company, brand, product and service names may be trademarks or registered trademarks

More information

False positive PET in lymphoma

False positive PET in lymphoma False positive PET in lymphoma Thomas Krause Introduction and conclusion 2 3 Introduction 4 FDG-PET in staging of lymphoma 34 studies with 2227 Patients CT FDG-PET Sensitivity 63 % 89 % (58%-100%) (63%-100%)

More information

PET. Can we afford PET-CT. Positron annihilation. PET-CT scanner. PET detection

PET. Can we afford PET-CT. Positron annihilation. PET-CT scanner. PET detection PET-CT Can we afford PET-CT John Buscombe New technology Combines functional information-pet anatomical information-ct Machine able to perform both studies in single imaging episode PET imaging depends

More information

Medical Radioisotopes Production Without A Nuclear Reactor

Medical Radioisotopes Production Without A Nuclear Reactor Medical Radioisotopes Production Without A Nuclear Reactor Henk van der Keur Laka Foundation, 22 May 2010 www.laka.org Contents 1 Introduction 2 2 The Emergence and Development of Nuclear Medicine 4 2.1

More information

Optimization of image quality through online motion correction

Optimization of image quality through online motion correction Advanced imaging technologies a revolution in diagnosis and treatment Optimization of image quality through online motion correction Oline Vinter Olesen December 10, 2010 Medical Solutions, Siemens Institute

More information

THORACIC DIAGNOSTIC ASSESMENT PROGRAM (DAP) PATIENT INFORMATION FOR:

THORACIC DIAGNOSTIC ASSESMENT PROGRAM (DAP) PATIENT INFORMATION FOR: central east regional cancer program in partnership with cancer care ontario THORACIC DIAGNOSTIC ASSESMENT PROGRAM (DAP) PATIENT INFORMATION FOR: Thoracic dap booklet March2012.indd 1 SCHEDULED TESTS YOUR

More information

SUPERCHARGED. CUSTOM-DESIGNED FOR CARDIOLOGY. Cardiology PACS. Cardiology

SUPERCHARGED. CUSTOM-DESIGNED FOR CARDIOLOGY. Cardiology PACS. Cardiology Cardiology PACS CUSTOM-DESIGNED FOR CARDIOLOGY. Now, you can count on powerful PACS performance in your cardiology department. CARESTREAM Vue for Cardiology can consolidate your disparate cardio lab systems

More information

AHE 232 Introduction to Clinical Software. Week eleven:

AHE 232 Introduction to Clinical Software. Week eleven: AHE 232 Introduction to Clinical Software Week eleven: Note: I have set up the entire curriculum for this class with weekly lesson plans. This will allow the Instructor to determine how to incorporate

More information

Truly digital PET imaging

Truly digital PET imaging Advanced Molecular Imaging Vereos PET/CT Truly digital PET imaging Philips proprietary Digital Photon Counting technology Vereos PET/CT is the first commercially available scanner to offer truly digital

More information

2016 CPT Radiology, ECHO, and PET Codes Requiring Review Modality Body Part Group # CPT Description Default CPT "1"

2016 CPT Radiology, ECHO, and PET Codes Requiring Review Modality Body Part Group # CPT Description Default CPT 1 26 CPT Radiology, ECHO, and PET Codes Requiring Review (Please Note: Group # and Default CPT "" are for internal claims processing use only) Modality Body Part Default CPT "" CT Head 748 CT orbit, sella

More information

MAJOR ACHIEVEMENTS IN NUCLEAR CARDIOLOGY. Advances in technical aspects of myocardial perfusion SPECT imaging

MAJOR ACHIEVEMENTS IN NUCLEAR CARDIOLOGY. Advances in technical aspects of myocardial perfusion SPECT imaging MAJOR ACHIEVEMENTS IN NUCLEAR CARDIOLOGY Advances in technical aspects of myocardial perfusion SPECT imaging Piotr J. Slomka, PhD, a James A. Patton, PhD, b Daniel S. Berman, MD, a and Guido Germano, PhD

More information

MDCT Technology. Kalpana M. Kanal, Ph.D., DABR Assistant Professor Department of Radiology University of Washington Seattle, Washington

MDCT Technology. Kalpana M. Kanal, Ph.D., DABR Assistant Professor Department of Radiology University of Washington Seattle, Washington MDCT Technology Kalpana M. Kanal, Ph.D., DABR Assistant Professor Department of Radiology University of Washington Seattle, Washington ACMP Annual Meeting 2008 - Seattle, WA Educational Objectives Historical

More information

Health Policy Advisory Committee on Technology

Health Policy Advisory Committee on Technology Health Policy Advisory Committee on Technology Technology Brief PET MRI integrated hybrid scanners February 2012 State of Queensland (Queensland Health) 2012 This work is licensed under a Creative Commons

More information

Interview with David Djang, MD On PET Scan in Oncology: Principles and Practice

Interview with David Djang, MD On PET Scan in Oncology: Principles and Practice Interview with David Djang, MD On PET Scan in Oncology: Principles and Practice By Howard (Jack) West, MD May, 2009 Hello and welcome to the GRACE audio podcast on PET scanning. This one is with Dr. David

More information

Cardiac CT Emerging Role and Current Indications

Cardiac CT Emerging Role and Current Indications Cardiac CT Emerging Role and Current Indications Dr. Felix Keng MBBS, FRCP (Lond), FAMS, Dip CBNC, Dip CBCCT, MMed (Int Med), FAPSC Director, Nuclear Cardiology National Heart Centre, Singapore Adjunct

More information

Non-invasive functional testing in 2014

Non-invasive functional testing in 2014 Non-invasive functional testing in 2014 Bjarne Nørgaard Department Cardiology B Aarhus University Hospital Skejby, Disclosures: Research grants: Edwards and Siemens Non-invasive functional testing in 2014

More information

Hybrid Imaging PET/MR

Hybrid Imaging PET/MR Hybrid Imaging PET/MR Marco Aiello 1, Marco Salvatore 2 1- SDN Istituto di Ricerca Diagnostica Nucleare, Napoli 2-Istituto di Biostrutture e Bioimmagini, CNR maiello@sdn-napoli.it Società Italiana di Fisica

More information

SPECT-CT. 자료: Simens

SPECT-CT. 자료: Simens 12 주차 SPECT - CT SPECT-CT 자료: Simens Gantry Overview 전면부 Gantry Overview 후면부 Blowers CT 겐트리의 냉각장치로써 냉각 및 정화된 공기를 주입 XTA X-ray Tube High Voltage Tank SRS Slip ring system. 별도의 Wire 없이 Tube와 Frame간에 전기적

More information

Scott Hubbell, MHSc, RRT-NPS, C-NPT, CCT Clinical Education Coordinator/Flight RRT EagleMed

Scott Hubbell, MHSc, RRT-NPS, C-NPT, CCT Clinical Education Coordinator/Flight RRT EagleMed Scott Hubbell, MHSc, RRT-NPS, C-NPT, CCT Clinical Education Coordinator/Flight RRT EagleMed Identify the 12-Lead Views Explain the vessels of occlusion Describe the three I s Basic Interpretation of 12-Lead

More information

SPECT and PET imaging in porcine inflammation and infection models. UCPH pig model network seminar

SPECT and PET imaging in porcine inflammation and infection models. UCPH pig model network seminar SPECT and PET imaging in porcine inflammation and infection models UCPH pig model network seminar Friday November 21. 2014, 8.30 12.00, auditorium A2 70.02, Thorvaldsensvej 40, 1871 Frederiksberg C. See

More information

Ga-68 PET. John Buscombe

Ga-68 PET. John Buscombe Ga-68 PET John Buscombe Introduction n Ga-68 a new radionuclide n PET based n Chemistry can be difficult n Used primarily with DOTATATE n Now also used with other agents In-111 octreotide v F-18 FDG in

More information

Cognitive Neuroscience. Questions. Multiple Methods. Electrophysiology. Multiple Methods. Approaches to Thinking about the Mind

Cognitive Neuroscience. Questions. Multiple Methods. Electrophysiology. Multiple Methods. Approaches to Thinking about the Mind Cognitive Neuroscience Approaches to Thinking about the Mind Cognitive Neuroscience Evolutionary Approach Sept 20-22, 2004 Interdisciplinary approach Rapidly changing How does the brain enable cognition?

More information

Cardiac Dedicated Ultrafast SPECT Cameras: New Designs and Clinical Implications

Cardiac Dedicated Ultrafast SPECT Cameras: New Designs and Clinical Implications Cardiac Dedicated Ultrafast SPECT Cameras: New Designs and Clinical Implications Ernest V. Garcia, Ph.D, Endowed Professor of Cardiac Imaging Professor of Radiology, Emory University School of Medicine,

More information

Society of Nuclear Medicine Procedure Guideline for Myocardial Perfusion Imaging

Society of Nuclear Medicine Procedure Guideline for Myocardial Perfusion Imaging Society of Nuclear Medicine Procedure Guideline for Myocardial Perfusion Imaging version 3.0, approved June 15, 2002 Authors: H. William Strauss, MD (Memorial Sloan Kettering Cancer Center, New York, NY);

More information

Positron Emission Tomography (PET) Detector Development for Plant Biology

Positron Emission Tomography (PET) Detector Development for Plant Biology Positron Emission Tomography (PET) Detector Development for Plant Biology Objectives Develop limited angle PET tomography for application in plant biology research Apply the technology to studying dynamics

More information

GENESEE/FINGER LAKES REGION PET CAPACITY AND UTILIZATION REPORT

GENESEE/FINGER LAKES REGION PET CAPACITY AND UTILIZATION REPORT GENESEE/FINGER LAKES REGION PET CAPACITY AND UTILIZATION REPORT December 2015 SECTION ONE: INTRODUCTION This report provides information on the availability and utilization of Positron Emission Tomography

More information

Local Coverage Article: NCD Coding Article for Positron Emission Tomography (PET) Scans Used for Non- Oncologic Conditions (A53134)

Local Coverage Article: NCD Coding Article for Positron Emission Tomography (PET) Scans Used for Non- Oncologic Conditions (A53134) Local Coverage Article: NCD Coding Article for Positron Emission Tomography (PET) Scans Used for Non- Oncologic Conditions (A53134) Contractor Information Contractor Name Novitas Solutions, Inc. Article

More information

Heart Center Packages

Heart Center Packages Heart Center Packages For more information and appointments, Please contact The Heart Center of Excellence at the American Hospital Dubai Tel: +971-4-377-6571 Email: heartcenter@ahdubai.com www.ahdubai.com

More information

Magnetic Resonance Quantitative Analysis. MRV MR Flow. Reliable analysis of heart and peripheral arteries in the clinical workflow

Magnetic Resonance Quantitative Analysis. MRV MR Flow. Reliable analysis of heart and peripheral arteries in the clinical workflow Magnetic Resonance Quantitative Analysis MRV MR Flow Reliable analysis of heart and peripheral arteries in the clinical workflow CAAS MRV Functional Workflow Designed for imaging specialists, CAAS MRV

More information

Diagnostic Imaging Services

Diagnostic Imaging Services Diagnostic Imaging Services Ultrasound Platinum Medical Centre The Wellington Hospital South Building Wellington Diagnostics and Outpatients Centre Introduction The Wellington Hospital is home to the most

More information

SNM: Advancing Molecular Imaging and Therapy. June 15, 2009 Toronto

SNM: Advancing Molecular Imaging and Therapy. June 15, 2009 Toronto SNM: Advancing Molecular Imaging and Therapy June 15, 2009 Toronto Robert W. Atcher, Ph.D., M.B.A. SNM President SNM Isotope Survey Results!! "# $% $&# '&( ' &)) Frederic H. Fahey, D.Sc. Chair, SNM Scientific

More information

Efficient Evaluation of Chest Pain

Efficient Evaluation of Chest Pain Efficient Evaluation of Chest Pain Vikranth Gongidi, DO FACC FACOI Indian River Medical Center Vero Beach, FL No Disclosures Outline Background Chest pain pathway Indications for stress test Stress test

More information

The Importance of Following the PROTOCOL in Clinical Trials

The Importance of Following the PROTOCOL in Clinical Trials The Importance of Following the PROTOCOL in Clinical Trials Presentation Objectives: Upon completion of this presentation, participants will be able to: Describe the following terms: Protocol, Protocol

More information

From Bioinformatics to Health Decision Support

From Bioinformatics to Health Decision Support From Bioinformatics to Health Decision Support Bart De Moor ESAT-SCD KatholiekeUniversiteitLeuven A: Kasteelpark Arenberg 10, B-3001 Leuven Belgium T: +32(0)475 2 8 7052 W: www.esat.kuleuven.be E: bart.demoor@esat.kuleuven.be

More information

Long-Term Effects of Drug Addiction

Long-Term Effects of Drug Addiction Long-Term Effects of Drug Addiction Part 1: Addiction is a chronic disease Drug addiction is considered a chronic brain disease because drugs cause long-lasting changes in brain structure and function.

More information

Factors Affecting Blood Pressure. Vessel Elasticity Blood Volume Cardiac Output

Factors Affecting Blood Pressure. Vessel Elasticity Blood Volume Cardiac Output Factors that Affect Pressure Graphics are used with permission of: Pearson Education Inc., publishing as Benjamin Cummings (http://www.aw-bc.com) Page 1. Introduction pressure is affected by several factors:

More information

Truly digital PET imaging

Truly digital PET imaging Truly digital PET imaging Philips proprietary Digital Photon Counting technology Vereos PET/CT is the first commercially available scanner to offer truly digital PET, resulting in significantly improved

More information

Press. Siemens solutions support diagnosis and treatment of cardiovascular diseases

Press. Siemens solutions support diagnosis and treatment of cardiovascular diseases Press Healthcare Erlangen, August 29, 2015 ESC 2015: ExCel London Exhibition and Convention Center, Booth #G700 Siemens solutions support diagnosis and treatment of cardiovascular diseases New cardiovascular

More information

Signal-averaged electrocardiography late potentials

Signal-averaged electrocardiography late potentials SIGNAL AVERAGED ECG INTRODUCTION Signal-averaged electrocardiography (SAECG) is a special electrocardiographic technique, in which multiple electric signals from the heart are averaged to remove interference

More information

Improvements in quality and quantification of 3D PET images

Improvements in quality and quantification of 3D PET images Improvements in quality and quantification of 3D PET images The resolution of PET depends on some effects impossible to be readily corrected The implementation of 3D spatially-variant PSF (radially asymmetric)

More information

What Is A Nuclear Medicine And Medical Setting?

What Is A Nuclear Medicine And Medical Setting? With nuclear medicine and molecular imaging, physicians can obtain unique insights into a patient s body that allow for a more personalized approach to the evaluation and management of heart disease, cancer

More information