Airtight with products from ISOCELL outer wall, timber frame / new / example 1
|
|
- Karin Underwood
- 7 years ago
- Views:
Transcription
1 outer wall, timber frame / new / example 1 spaced battens OMEGA Wind seal used under claddings without gaps, sd= 0,02m sealed with AIRSTOP Sealant Sprint OMEGA Facade lining, used under claddings with horizontal shadow gaps of up to 20 mm, sd= 0,17m, sealed with OMEGA facade tape STAMISOL FA under claddings without limitation of the percentage of the gaps (exept glass), sd=0,09m sealed with the sealant Stamcoll N 55 STAMISOL Color, also used under glass, sd= 0,05m, sealed with the sealant Stamcoll N 55 FH Vapour barrier fabric-reinforced sd=6,45m AIRSTOP Vapour barrier, sd= 18m FH Fleece vapour barrier, sd=2,5m or OSB- panel airtight sealed with AIRSTOP Flex Adhesive tape AIRSTOP Adhesive tape AIRSTOP sealant Sprint TJI- beam Insulation, e.g. ISOCELL cellulose lathing cladding
2 outer wall, timber frame / new / example 2 DWD panel Sd = approx. 0,2 m sealed with the AIRSTOP Adhesive tape OSB panel sd= 3 m to 10 m airtight sealed with the AIRSTOP Flex Adhesive tape TJI- beam Insulation, e.g. ISOCELL cellulose
3 outer wall, timber frame / new / example 3 OSB panel sd= 5 m to 10 m sealed with AIRSTOP Adhesive tape AIRSTOP Vapour barrier, sd= 18 m airtight sealed with AIRSTOP Flex Adhesive tape Junctions with AIRSTOP sealant Sprint TJI- beam Insulation, e.g. ISOCELL cellulose
4 outer wall, timber frame / new / example 4 Facade insulation panels, wood fibre plastered sd= 0,3 m The usage of EPS facade insulation is also possible, the correct vapour barrier must be determined in each case. FH Vapour barrier fabric-reinforced sd=6,45m AIRSTOP Vapour barrier, sd= 18m FH Fleece vapour barrier, sd=2,5m airtight sealed with AIRSTOP Flex Adhesive tape AIRSTOP Adhesive tape AIRSTOP sealant Sprint TJI- beam Insulation, e.g. ISOCELL cellulose
5 outer wall / renovation / from outside plaster panel wood beam ISOCELL cellulose insulation The insulation is done from outside. The openings can bei sealed with cork stoppers, the approval of the usage must be obtained by the manufactorer of the facade insulation panels. wooden panel spaced battens lathing TJI- beam old brickwork
6 outer wall / renovation / from inside OSB panel sd = approx. 6m FH Vapour barrier fabric-reinforced sd=6,45m airtight sealed with AIRSTOP Flex Adhesive tape AIRSTOP Adhesive tape ISOCELL cellulose insulation It is important that the connection of the ISOCELL cellulose to the brickwork is without gaps to insure the transport of the humidity (no use of vapour stop). The use of OSB or FH Vapour barrier fabricreinforced is recommended. Brickwork plastered outside and inside
7 outer wall / renovation / brickwork outside brickwork Plaster inside Insulation / mineral wool existant fair faced brickwork existant, outside wood beam with ISOCELL cellulose insulation diffusive wind seal spaced battens/ air covering
8 outer wall / renovation / framework plaster panel The institute for lowest energy houses (Passive Houses) recommends the use of a diffusive covering like plaster plates without vapour barriers in addition to ISOCELL cellulose insulation because of the capillary transport of the humidity to the inside of the construction. ISOCELL cellulose insulation framework
9 outer wall / renovation / double brickwork! Core insulation with GRANUBLOW or SLS 20 roller shutter Window with window ledge Fair faced brickwork old brickwork!!! Advice: It is recommended to inspect the double brickwork carefully to discover all gaps and holes!
10 roof, / new / example 1 / > 15 pitch OMEGA or OMEGA light roof underlay unsupported or supported, bonded with OMEGA Quilli TJI- beam Lathing with OMEGA nail seal tape ISOCELL cellulose insulation FH Vapour barrier fabric-reinforced sd=6,45m AIRSTOP Vapour barrier, sd= 18m FH Fleece vapour barrier, sd=2,5m airtight sealed with AIRSTOP Flex Adhesive tape AIRSTOP Adhesive tape AIRSTOP sealant Sprint
11 roof, / new / example 2 / > 15 pitch OMEGA or OMEGA light roof underlay on OSB (sd ~ 4m), bonded with OMEGA Quilli TJI- beam Lathing with OMEGA nail seal tape ISOCELL cellulose insulation AIRSTOP Vapour barrier, sd= 18m OSB airtight sealed with AIRSTOP Flex Adhesive tape AIRSTOP Adhesive tape AIRSTOP sealant Sprint
12 roof, / new / example 3 / < 15 pitch STAMISOL PACK, sd = 1,02m, roof underlay unsupported or supported, bonded with STAMCOLL N55 sealant or melted with a hot air dryer TJI- beam Lathing with OMEGA nail seal tape ISOCELL cellulose insulation AIRSTOP Vapour barrier, sd= 18m airtight sealed with AIRSTOP Flex Adhesive tape AIRSTOP Adhesive tape AIRSTOP sealant Sprint
13 roof / > 15 pitch OMEGA roof underlay on wooden plate bonded with OMEGA Quilli rafter brick coverage / lathing Lathing with OMEGA nail seal tape ISOCELL cellulose insulation XPS or wood fibre panel FH Vapour barrier fabric-reinforced sd=6,45m AIRSTOP Vapour barrier, sd= 18m FH Fleece vapour barrier, sd=2,5m airtight sealed with AIRSTOP Flex Adhesive tape AIRSTOP Adhesive tape AIRSTOP sealant Sprint lathing 8/10 x 2,5cm, dimension between axes 33cm, max. 40cm Plaster panel or wooden fire protection panel
14 roof / > 15 pitch / extension with OSB panel OMEGA roof underlay on wooden plate bonded with OMEGA Quilli rafter brick coverage / lathing Lathing with OMEGA nail seal tape ISOCELL cellulose insulation OSB panel lathing 8/10 x 2,5cm, dimension between axes 33cm, max. 40cm ÖKO Natur vapour barrier sd=6,45m Airtight sealed with the AIRSTOP sealing system lathing 35/50 plaster panel
15 flat roof Vapour tight flat roof sheating Du to the solar impact to prefer in black Mostly with gravel and often on OSB because of static reasons TJI- beam ISOCELL cellulose insulation Instead of OSB panel better: FH Fleece vapour barrier, sd=2,5m, because of dehydration to the inside in summer airtight sealed with AIRSTOP Flex Adhesive tape AIRSTOP Adhesive tape AIRSTOP sealant Sprint often OSB panel
16 roof / renovation / example 1 Old bituminous sheating on wooden panel sd ~ 70m lathing and red brick covering existant: wood fibre panel plaster new: ISOCELL cellulose insulation insulated from the attic important: the airtightness has to be guaranteed (plaster without gaps! Connections, )!!
17 wooden panel Airtight with products from ISOCELL collar beam / ceiling / renovation Insulation opening with cork stopper old rafter insulation existant lathing existant covering ISOCELL cellulose insulation important: the airtightness has to be guaranteed (plaster without gaps! Connections, )!!
18 roof / renovation from inside old roof covering Lathing without sheating Wood fibre panel as roof underlay (not rain tight) Level old Level new ½ I- beam Lathing new ISOCELL cellulose insulation Vapour barrier lathing rafter old
19 roof inside and outside existant/ renovation old roof covering Lathing with sheating ISOCELL insulation tube rafter old existant covering insulation existant Advice: construction has to be proofed referring to building physics! ISOCELL cellulose insulation insulated from the attic
20 roof flattish/ renovation old roof covering ISOCELL insulation fibre open blown trussed rafter concrete existant covering Advice: construction has to be proofed referring to building physics!
Multi-layer Insulation Blanket for Roofs
Multilayer Insulation Blanket for Roofs Thermal Insulation in a 40mm thin, flexible, multilayer membrane Meets requirements of L1A, L1B 2010 In accordance with BR443 NHBC Acceptance Pitched & Flat roof
More informationCERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011
CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS
More informationWalls. Add Strength and Water Resistance When Repairing Your. Replace damaged framing members when walls are open
Add Strength and Water Resistance When Repairing Your Walls Any home repair or remodeling work you do presents an opportunity to make your home fare better in the next storm. Whether you are just replacing
More informationEnergy Company Obligation (ECO): Technical Monitoring Questions
Energy Company Obligation (ECO) Technical Monitoring Questions v1 30/05/2013 Energy Company Obligation (ECO): Technical Monitoring Questions Under ECO suppliers are required to instruct suitably qualified
More informationNRG 75 CRF NRG GREENBOARD WALL SYSTEM
NRG GREENBOARD WALL SYSTEM NRG Energy Efficient Building Systems is pleased to announce a revolution in lightweight cladding systems. NRG Building Systems is the first and only company to achieve CodeMark
More informationfire separating walls #2
210108 fire separating walls #2 ISSUE BSA has identified a number of instances of defective fire separating walls in duplexes, town houses and multi-residential complexes. The system of fire separating
More informationBuilding Regulations for the Conservation of Fuel and Power
Insulation CI/SfB Rn7 M2 First Issue April 2014 Building Regulations for the Conservation of Fuel and Power ENGLAND EXISTING DWELLINGS 2013 EDITION Low Energy Low Carbon Buildings Contents Page Introduction
More informationThe better way to build TM. Installation Manual. EXTERIOR WALL SIPs
The better way to build TM Installation Manual EXTERIOR WALL SIPs July 2015 EXTERIOR WALL SIPs Installation Manual Table of Contents Topics General Requirements................................... 3 Materials..............................................
More informationRockwool Flexi Insulation Application Guide
Pitched roof Rafters InterMediate floors INTERNAL partitions external Framed walls separating floors Separating Walls Rockwool Flexi Insulation Application Guide Ground floor The perfect fit for any framed
More informationThe compliance of a roof to part of a new house at 28D Rata Street, Oxford, Waimakariri
Determination 2009/103 The compliance of a roof to part of a new house at 28D Rata Street, Oxford, Waimakariri 1. The matters to be determined 1.1 This is a determination under Part 3 Subpart 1 of the
More informationWindow Installation in Passive Houses ways to achieve superior insulation, airtightness and durability
Window Installation in Passive Houses ways to achieve superior insulation, airtightness and durability Florian Speier Swiss Architect CPHC co-founder, Zola European Windows What makes a window perform?
More informationBuilding Construction. Lightweight construction. Conventional Construction
Ventilation 53 Building Construction The firefighter s ability to safely and efficiently ventilate a building through its roof will depend to some degree on the firefighter s understanding of roof construction.
More informationIncluding. Rubershield-Pro. Breather Membrane
Including RubershieldPro Breather Membrane 2 Ruberoid produces a wide range of underslating membranes, primarily to be installed below tiles, slates or metal roofing providing a secondary barrier against
More information..." by A Elmroth and P Levin.
ABSTRACT This survey describes how external walls and joints are constructed in practice. The paper gives you an opportunity to compare how successful the implementation of airtightness has been in Sweden
More informationSection 3.1.2. Timber Frame Walls. Single layer between studs. Single layer between studs with service void. Between studs with insulated lining
Section Timber Frame Walls Single layer between studs Product: Earthwool FrameTherm Rolls and Slabs Tf01 Single layer between studs with service void Product: Earthwool FrameTherm Rolls and Slabs Tf02
More informationAND MEMBRANES ROOFING UNDERLAYS. www.fakro.com
AND MEMBRANES 010 ROOFING UNDERLAYS 1 HO DOES YOUR ROOF BREATHe? MEMBRANES THE WAY to A WARM AND DRY ROOF HO HO HO HO HO HO WATERTIGHTNESS The FAKRO Company offers a wide range of membranes and underlays
More informationsolutions & tips six Wise Energy Guide Building envelope solutions and simple tips AIR SEALING
Wise Energy Guide solutions & tips 32 AIR SEALING Is your house leaking money? six Building envelope solutions and simple tips If your home is like most, the greatest amount of heat loss is from air leakage;
More informationresearch highlight Highly Energy Efficient Building Envelope Retrofits for Houses
research highlight June 2012 Technical Series 12-103 Highly Energy Efficient Building Envelope Retrofits for Houses introduction In Canada approximately 30% of all energy is consumed in buildings, with
More informationArchitectural integration of solar thermal collectors into the building envelope
Architectural integration of solar thermal collectors into the building envelope Charlotta Isaksson, Thomas Müller, Irene Bergmann AEE - Institute for Sustainable Technologies (AEE INTEC) A-8200 Gleisdorf,
More informationSchool in Schwanenstadt, Austria
School in Schwanenstadt, Austria 1. INTRODUCTION PROJECT SUMMARY - building period 1960s - numerous expansions SPECIAL FEATURES - Renovation to meet Passive House Standard - decentralized ventilation system
More informationCase Study Family Room Renovation 3br family home, Melbourne
Family Room Renovation 3br family home, Melbourne In a Nutshell With time and budget constraints we often renovate just one room at a time. This case study looks at a family room renovation where the key
More informationGYPROCK PARTY WALL INTERTENANCY WALL SYSTEMS FOR CLASS 1 BUILDINGS
GYPROCK PARTY WALL INTERTENANCY WALL SYSTEMS FOR CLASS 1 BUILDINGS CONTENTS Introduction 2 Applications 3 Advantages 3 Components 3 6 Design Considerations 7 8 System Features 10 Typical installation Sequence
More informationSystem 5000 FLAME-FREE, FELT SYSTEM, INSTALLED USING HOT AIR, TOTALLY ELIMINATING FIRE RISK AND PROVIDING A BITUMEN ALTERNATIVE TO SINGLE PLY
CI/SfB Oct 12 (47) Ln Uniclass L524 FLAME-FREE, FELT SYSTEM, INSTALLED USING HOT AIR, TOTALLY ELIMINATING FIRE RISK AND PROVIDING A BITUMEN ALTERNATIVE TO SINGLE PLY Bailey Flame-free felt roofing Bailey
More informationEnvelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit
R-H-DI1 INSULATION BATT NR-E-IB1 Avoid Using Batt Insulation With Metal Framing Batt insulation should not be used with metal framing systems. Although it is common to see fiberglass batt insulation installed
More informationThe formation of roof waterproofing details calls for
3.5 BUILT-UP ROOFING DETAIL DESIGN INTRODUCTION The formation of roof details calls for a combination of the skills of the designer and the roofer. There are many different approaches to detail design
More informationFire 2This Technical Bulletin has been commissioned by the UK SIP Association in
REV 1-12.12.11/TB002 Technical Bulletin Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in conjunction with TRADA Technology and is intended to provide the reader with introductory
More informationSealing & Bonding Sika solutions for Window Installation
Sealing & Bonding Sika solutions for Window Installation Sika s Comprehensive Fenestration Competence Benefit of our solution Globally, growing requirements to save energy and to utilize natural resources
More informationrationel WINDOWS WITH VISION
Brick / Blockwork 340mm Cavity Wall Interface Detail Cill BW-001A 5 x 50mm Woodscrews (Staggered) By Installer 20 x 90mm Standard Timber Packer With Upstand Bedded To Frame In Silicone By Installer Aluminium
More informationPassive house rehabilitation of post war residential building in Zug, Switzerland
Passive house rehabilitation of post war residential building in, Switzerland Owner: Erbengemeinschaft Ducret Architect: Miloni & Partner, Wettingen Energy concept designer: Zurfluh & Lottenbach, Luzern
More informationRev 1-12.2013. Code of Practice. SIP Technology. www.uksips.org
Rev 1-12.2013 Code of Practice SIP Technology www.uksips.org What are Structural Insulated Panels (SIPS)? SIPS are prefabricated, high performance, lightweight, building panels that can be used in floors,
More informationSample Drawing Package for One and Two Family Dwelling Applications
Sample Drawing Package for One and Two Family Dwelling Applications For a full list of submission requirements, refer to the relevant checklist for your application found on our website: http://vancouver.ca/home-property-development/application-forms-and-checklists.aspx
More informationGood Craftsmanship Guide. Carpentry and Joinery- Carcassing
Good Craftsmanship Guide Carpentry and Joinery- Carcassing Introduction This Good Craftsmanship Guide highlights key problems with the major elements of Carpentry and Joinery - Carcassing, and gives guidance
More informationRESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings
More informationINSTALLATION. General. Important Note. Design. Transport
General The roof trusses you are about to install have been manufactured to precise engineering standards. To ensure that the trusses perform as designed, it is essential that they be handled, erected
More informationManagement Consultancy Training. Asbestos Materials. Residential Guide
Asbestos Materials Residential Guide This guide highlights some of the more common asbestos containing materials (ACMs) in low occupancy residential buildings, their uses and likely locations. The guide
More informationWe care about. Environmentally-Friendly Building Products from Renewable Resources. natural building products. Product range overview
http://upload.wikimedia.org/wikipedia/commons/a/ae/flag_of_the_united_kingdom.svg.0.0 :8 Seite von Environmentally-Friendly Building Products from Renewable Resources Product range overview We care about
More informationMark Cramer Inspection Services, Inc.
Mark Cramer Inspection Services, Inc. 492 Twentieth Avenue, Indian Rocks Beach, FL 34635-2970 (727) 595-4211 Fax (727) 596-7583 Certified Member #12085 American Society of Home Inspectors Construction
More information!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035
Decra Plus Drawing no DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 Description Shown In Decra Brochure Most Commonly Used Detail t~êã=oççñ=b~îéë=aéí~áä=b~îéë=lîéêü~åö=táíü=fåëìä~íéç=c~ëåá~=~åç=pçññáí
More informationTimber Frame Construction
Timber Frame Construction Introduction Design and Detailing What is timber? Failure modes History of timber frame construction Forms of timber frame construction Live and dead loads Wind loads Roof construction
More informationPerformance of 8 Passive House Envelopes in Cold Climates
7 th Annual North American Passive House Conference September 27-30, 2012 Denver CO Performance of 8 Passive House Envelopes in Cold Climates Rolf Jacobson, LEED AP CSBR, University of Minnesota ZEB, Norwegian
More informationHigh R-Value Does Not Always Mean High Performance
High R-Value Does Not Always Mean High Performance By Charlie Gohman, Building Science and Efficiency Manager, Energy Office, Arizona Department of Commerce Ever since the energy crisis of the 70s we have
More informationMineral fibreglass insulation
Isover MULTIMAX 30 Specification code: MW - EN 13162 - T5 - MU1 - WS - WL(P) - AF r 5 TeChNICaL SPeCIFICaTION Insulating slabs made of Isover fibreglass wool. The production method is based on the fibering
More informationThe Pleasance, Edinburgh
Refurbishment Case Study 5 DRAFT The Pleasance, Edinburgh Insulation of coom ceiling, attic space & lightwell 2 nd edition The views expressed in commissioned case studies are those of the authors and
More informationThe Case for Cross Laminated Timber: Part 2
Learning Objectives The Case for Cross Laminated Timber: Part 2 Opportunities and Challenges for a New Class of Timber Product 1. Review answers to common questions regarding the design and construction
More informationAsphalt Shingle Application Requirements
Alberta Allied Roofing Association Asphalt Shingle Application Requirements Section 1 Roof Decks 1.1 General Asphalt Shingles are not permitted to be installed directly over rigid insulation. When Asphalt
More informationPB301 July 2009. Lightweight Building Solutions. Bushfire Protection. www.boral.com.au/bushfireprotection
PB301 July 2009 Lightweight Building Solutions Bushfire Protection www.boral.com.au/bushfireprotection Attached or adjacent within 6m roofed structures such as garages, carports, verandas and the like,
More informationPrelease Schedule of Condition and Want of Repairs at Milton Keynes for May
Prelease Schedule of Condition and Want of Repairs at Milton Keynes for May Instruction To carry out Inspection of the Industrial Unit, to identify areas of repair to the Unit at commencement of the Lease.
More informationSchlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing
Substrate, structural panel, bonded waterproofing The universal substrate for tiles Perfect covering No matter whether you work with mosaics or large format tiles, an absolutely level substrate with straight
More informationSTRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM
Chapter 9 STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM 9.1 BACKGROUND Steel is widely used in the construction of multi-storey buildings. However, steel construction is seldom used and is traditionally
More informationISO Types 1-6: Construction Code Descriptions
ISO 1 Frame (combustible walls and/or roof) Class 1B Buildings where the exterior walls are wood or other combustible materials, including construction where the combustible materials are combined with
More informationFIRE RATED GLAZING System Guide
SYSTEM GUIDE Issue date: 05-05-2015 Expiry date: 31-12-2016 System Guide Introduction Pyropanel Developments are specialists in fire rated glazing solutions, and our systems are designed for easy installation
More informationLinea Weatherboard DIRECT FIX CONCRETE SLAB AND SOFFIT FIGURE 1
Top plate Stud Soffit lining 45mm min nog Fix scotia bead Building underlay/james Hardie rigid air barrier Soffit Detail Building underlay/james Hardie rigid air barrier Bottom plate 25mm wide cant strip.
More informationThe right solutions. However, it is inevitable that with the introduction of any new construction system the question arises How does it compare?
Value assessment. The right solutions. We Believe We believe that Porotherm offers both short and long term value to all involved in the building process - from bricklayer to client and everyone in between.
More informationBLACK JACK ALL WEATHER ROOF COATING
PAGE: 1 of 6 PRINT DATE: 16/09/2004 BLACK JACK ALL WEATHER ROOF COATING DESCRIPTION BLACK JACK ALL WEATHER ROOF COATING is a solvent based, full bodied black brushable compound with added fibres for reinforcement.
More informationElectrical Wiring Technical Bulletin
Electrical Wiring Technical Bulletin Overview In general, SIP construction is easier and more cost effective when things are planned and thought out before the panels are manufactured. This process will
More informationMold Preventing I nterior System
interior insulation and renovation boards A system of components that have been designed to work perfectly together to repair damage caused by mold. The system consists of boards, insulation wedges, reveal
More informationResidential Inspection Guidelines
Residential Inspection Guidelines 201 Pre-Pour Foundation Dimensions Building Location Certificate - if required in the building consent Construction and Advice Notes Check the building dimensions against
More informationSANS 1 0 1 7 7-9. www.spunchem.com FIRE PERFORMANCE SANS 428 ENERGY SAVER REFLECTIVE TIASA A MEMBER OF 2009/366 2009/367 2009/369 2008/341
REFLECTIVE ENERGY SAVER FIRE PERFORMANCE SANS 428 SANS 1 0 1 7 7-9 SANS 10177-10 SANS 10177-11 www.spunchem.com A MEMBER OF TIASA Thermal Insulation Association of Southern Africa 2009/66 2009/67 2009/69
More informationInstallation Details. D1 General D2 Walls D3 Ceilings D4 Reference. D Installation Details
D Installation Details D1 General D2 Walls D3 Ceilings D4 Reference D Installation Details D Contents D1 General Installation and Fastening Sequence for Steel Studs D1.1 Fastener Selection D1.3 D2 Walls
More informationFERMACELL Powerpanel H 2 O for Wet & Moisture affected areas
FERMACELL Powerpanel H 2 O for Wet & Moisture affected areas Powerpanel H 2 O is a cement based board from FERMACELL. Board Characteristics Board Thickness 12.5 mm Board Sizes 1000 x 1200 mm 50 sheets/pallet
More informationMinimizing Water Intrusion Through Roof Vents in High-Wind Regions
Minimizing Water Intrusion Through Roof Vents in High-Wind Regions http://www.fema.gov HURRICANE IKE RECOVERY ADVISORY Purpose: To recommend practices for minimizing water intrusion through roof vent systems
More informationRoofers Guide to Underslating Membranes
Roofers Guide to Underslating Membranes IKO is a worldwide enterprise, with more than 3000 employees, and manufacturing plants in Canada, the United States, United Kingdom, Belgium, Holland, France and
More informationHORIZONTAL INSTALLATION
THERMO/SOLAR Žiar s.r.o. MANUAL FOR INSTALLATION PV SUPPORTING FRAMES HORIZONTAL INSTALLATION Technical alternation reserved A1410 1 12/2014 CONTENT ORD.NO. PAGE Mounting information 3 Mounting, flat roof
More informationINSTALLATION INSPECTION GUIDE FOR 3RD PARTY INSPECTORS FOR PAREX USA EXTERIOR INSULATION AND FINISH SYSTEMS
INSTALLATION INSPECTION GUIDE FOR 3RD PARTY INSPECTORS FOR PAREX USA EXTERIOR INSULATION AND FINISH SYSTEMS Introduction This inspection guide is organized to follow the EIF System's Installation Guide.
More information0845 0098 980 www.nicholsonsts.com
0845 0098 980 www.nicholsonsts.com ROOFTRAK The IFP is revolutionising the way we fix things to roofs. Technical Director of a leading UK roofing system manufacturer The ROOFTRAK-IFP A revolutionary solution
More informationAdditions and Alterations
Additions and Alterations Addition and alteration construction is a miscellaneous grouping of home improvement and renovation projects that are generally geared toward the enhancement of an existing principal
More informationPassive Cross Laminated Timber Buildings
Final Report Passive Cross Laminated Timber Buildings Cerbof-project no. 76 Henrik Janols, Mats Rönnelid, Tina Wik, Dalarna University Matias Brännström, Stora Enso Wood Products Håkan Helling, Tommy Lövenvik,
More informationWindow Installation Instructions
Caution The correct installation methods of windows in full frame or insert applications is critical towards achieving the tested performance of the window and longterm enjoyment and energy savings for
More informationInstallation Guide. Bath and Wall Surrounds SERIES 7104 1021861-2-B
Installation Guide and Wall Surrounds SERIES 7104 1021861-2-B Thank You For Choosing Sterling We appreciate your commitment to Sterling value. Please take a few minutes to review this manual before you
More informationModuSec. Secure and efficient IT room solutions. Turnkey Modular Construction Fast clean build to any size or shape
ModuSec Secure and efficient IT room solutions Turnkey Modular Construction Fast clean build to any size or shape Room in room Standalone external build Transportable Modusec SR Options Modusec SR Options
More information2014 British Columbia Building Code Changes
District of Houston 250-845-2238 2014 British Columbia Building Code Changes A District of Houston interpretation of the 2014 Building Code Changes for 9.36 & 9.32 The following changes reflect the most
More informationFLASHMAN WINDOW AND DOOR FLASHING SYSTEM. Product. Scope. Appraisal No. 573 [2013]
FLASHMAN WINDOW AND DOOR FLASHING SYSTEM This Appraisal replaces BRANZ Appraisal No. 573 (2007). Amended 05 February 2016. BRANZ Appraisals Technical Assessments of products for building and construction.
More informationDuPont Tyvek ThermaWrap R5.0 Installation Guidelines for New Construction Using Stone Veneer or Lap Siding, e.g. Fiber Cement and Wood/Cedar
Tyvek ThermaWrap R5.0 Installation Guidelines for New Construction Using Stone Veneer or Lap Siding, e.g. Fiber Cement and Wood/Cedar VERSION 1/16 FOR SINGLE FAMILY HOMES AND LOW-RISE MULTI-FAMILY BUILDINGS
More informationAirtight Intelligence
VARIO - Airtight Intelligence The multitasking membrane The Vario System keeps heat in Airtight Intelligence Vario-System keeps draughts out beats present and future regulations saves energy Introducing
More informationPost-insulation of cellar ceiling and cellar walls
WP5 Education and Economic Promotion Post-insulation of cellar ceiling and cellar walls Educational product: New lecture material for training modules dealing with knowledge and skills how to apply suitable
More informationFS Deck Mounted Skylight Installation Instructions 15-90
FS FS Deck Mounted Skylight Installation Instructions 5-90 VAS 456-0909 5-90 FS is designed for roof pitch 5-90 deg. Accessories Refer to instructions for accessory type in questionor contact VELUX for
More informationPost and Beam Construction
Post and Beam Construction A Presentation By the Canadian Wood Council Canadian Conseil Wood canadien Council du bois Early settlers introduced the concept of post and beam construction in North America
More informationICC-ES Evaluation Report Reissued September, 2010 This report is subject to re-examination in one year.
ICC-ES Evaluation Report ESR-2270 Reissued September, 2010 This report is subject to re-examination in one year. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council
More informationDirectorate for the Built Environment Building Standards Division
Directorate for the Built Environment Building Standards Division BRE Scotland and Waterman Group Risk assessment of structural impacts on buildings of solar hot water collectors and photovoltaic tiles
More informationAll Weather Hall. Efficient, multipurpose & quick to build
All Weather Hall Efficient, multipurpose & quick to build ALL WEATHER HALL www.deboer.com www.deboer.com ALL WEATHER HALL A flexible solution for a multitude of needs All Weather halls from De Boer provide
More informationBritish Gypsum Guide to Timber Frame Construction. March 1998
British Gypsum Guide to Timber Frame Construction March 1998 Timber frame construction has a centuries long tradition in the UK, however, over the last 80 years it has continuously evolved to meet the
More informationwww.citiesinspection.com October 5, 2015 Dear Client,
www.citiesinspection.com October 5, 2015 Dear Client, On 9/14/2015, Cities Inspection Service, Inc. completed a building inspection of the property located at 123 Oak Street, Someplace, Minnesota for you.
More information12.1 Schlüter -KERDI-BOARD
I n n o v a t i v e p r o f i l e s 12.1 Schlüter -KERDI-BOARD S u b s t r a t e U N I V E R S A L S T R U C T U R A L P A N E L, B O N D E D W A T E R P R O O F I N G Application and Function Schlüter
More informationInnovation - High performance roof, wall and floor insulation board. delivering better performance
2010 VERSION 1 IRL High performance roof, wall and floor insulation board Innovation - delivering better performance PRODUCT SPECIFICATION INSTALLATION GUIDE I ve worked with Xtratherm for years, they
More informationWALLS Three common wall types are described below, with their insulation solutions.
APPENDIX 5: Building Envelope Insulation is vitally important for temperature controlled buildings. If fuel (and therefore money) is being used to heat a building, less fuel (and money) will be used if
More informationComposite Panel Firewall Systems
Composite Panel Firewall Systems part of the Protecting more than your business Insulated mineral fibre panels have excellent thermal and acoustic properties, ideal for factory and office partition walls.
More informationBuilding Condition Assessment Report
C2 - Nurses Resident (aka Administration) Building Condition Assessment Report Asset Address Address Construction Year Size (Gross Floor Area) Asset Type Floors Above Ground Inspection Date C2 - Nurses
More information- 1 - Element Type. 9 mm gypsum board, 50 mm mineral wool (glued) 9 mm gypsum board, 50 mm mineral wool (on wooden studs, at 300 mm centres)
concrete 160 mm concrete 180 mm concrete 200 mm concrete 220 mm concrete 230 mm concrete 240 mm concrete 260 mm calcium silicate block 214 mm calcium silicate block 240 mm calcium silicate block 265 mm
More informationCI SfB. (4-) Nn2. Onduline. Mini Profile. Onduline Garden Roof Range. Onduline Building Products Ltd
CI SfB (4-) Nn2 Onduline Mini Profile Onduline Garden Roof Range Onduline Building Products Ltd Onduline Garden Roof Range Onduline Mini Profile The new Onduline Mini Profile sheets have been designed
More informationVM ZINC : standing seam Guidelines for specification and installation
VM ZINC : standing seam Guidelines for specification and installation Junglim Architecture - QUARTZ-ZINC Roofing and cladding system in VM ZINC Roofs from a 3 pitch and facades Freedom with shape and appearance
More informationInternal wall insulation in existing housing
Energy Efficiency Best Practice in Housing Internal wall insulation in existing housing A guide for specifiers and contractors Cost-effective External wall appearance maintained Easier to install and maintain
More informationEuropean Technical Approval ETA 13/0526
European Technical Approval ETA 13/0526 Trade Name Holder of the approval Website Generic type and use of construction product DOLCEA i3 PCIM S.A. Rue du Péquet 54 5590 Achene (Ciney) Belgium www.isoproc.eu
More informationInsulation R-Value Comparisons
Insulation R-Value Comparisons American Ingenuity s component panels for the 22 48 domes contains seven inch thick rigid Expanded Polystyrene (E.P.S.) insulation which has an R value of 28. American Ingenuity
More informationFig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION
SIPS SCREWS WITH MINIMUM 1" PENETRATION IN WOOD MEMBER IN SIP WALL PANEL CONNECTED TO @ 24" O.C. MAXIMUM OUTSIDE SKIN EACH SIDE OF FRAMING TYP. AS RECOMMENDED BY FOAM CORE AS EACH SIDE OF FRAMING TYP.
More informationSika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades
Construction Sika For Sealing and Waterproofing Construction Gaps in Building Façades Waterproof and Airtight Flexible Seal Controlled Vapour Diffusion Bonds to any Building Substrate Prevents Interstitial
More informationSuperform Products Ltd.
TYPICAL CORNER REINFORCING NOTE : SEE ENGINEERED REBAR SCHEDULES SUPPLIED BY THE MANUFACTURER STEEL REINFORCEMENT WALL CORNER 90 Copyright 2012 Sept. 2012 5.1.1 Rebar Spacing 6" 12" Max. Load LB./FT. 2000
More informationDuPont Tyvek ThermaWrap R5.0 Installation Guidelines for New Construction Using Vinyl, Brick and Stone Claddings
Tyvek ThermaWrap R5.0 Installation Guidelines for New Construction Using Vinyl, Brick and Stone Claddings VERSION 1/16 FOR SINGLE FAMILY HOMES AND LOW RISE MULTI-FAMILY BUILDINGS LESS THAN 4 STORIES Tyvek
More informationHigh Performance Solutions and Compounds for Roofing and Structural Waterproofing
High Performance Solutions and Compounds for Roofing and Structural Waterproofing IKO is a worldwide group of companies with extensive experience and specialist technical knowledge. IKO is a leader in
More informationDURATION STORM. TruDefinition. TruDefinition Duration STORM Shingles are a component of the Owens Corning Total Protection Roofing System.
TruDefinition DURATION STORM Impact-Resistant Shingles with WeatherGuard and SureNail Technologies Onyx Black TruDefinition Duration STORM Shingles are a component of the Owens Corning Total Protection
More informationDow Corning PROPRIETARY. Dow Corning. A Thermal Modelling Comparison of Typical Curtain Wall Systems
Dow Corning A Thermal Modelling Comparison of Typical Curtain Wall Systems Introduction Today s Aim To understand the meaning of a U value and window energy ratings Discuss the drivers for energy efficiency
More information