SO-LOW LAB FREEZERS TO -85 C
|
|
|
- Darren Lindsey
- 9 years ago
- Views:
Transcription
1 SO-LOW LAB FREEZERS TO -85 C RESEARCH - TESTING CLINICAL APPLICATIONS PHARMACY FREEZERS LIFE SCIENCES INDUSTRIAL USE Spartan Drive, Cincinnati, Ohio 45215, USA (513) Fax: (513)
2 Ultra-Low Temperature Freezers Dependable Operation by Design Specifications Control System: Digital temperature control Compressor life is extended by an energy-saving low stage which operates only on demand. Compressors are protected with a constant flow of refrigerant Heat is efficiently and effectively dissipated by an air-cooled condenser with two heavy-duty fans. Condenser requires no liquid coolant. General Specifications MODEL CU. FT./LITERS TEMPERATURE Temperature Range Freezer has an automatic timer system that will restart the unit in case of power failure. Frost and ice build-up along the gasket is minimized by a heater harness located beneath the channel cap away from the inner chamber. CFC-Free R-508B and R-404A refrigerants. Digital temperature control with dual display and adjustable temperature range. Scan button for setting tem- perature and tamper proof lockout. Quick pull-down to operating temperature with efficient and reliable cascade refrigeration. Two large hermetic compressors ensure rapid pull-down of product load. Because of the unique design of the So-Low freezers, the pressure in the refrigeration system is held very low, eliminating excessive heat build up. This low pressure allows the freezer to operate efficiently, extending compressor life. Refrigeration System - CFC Free: Cascade Type - Two hermetic type compressors - Large air cooled Condenser - Cooling coils - Copper tubing Insulation - CFC Free: Minimum of five inches of polyurethane - Sublids - Double sealed gaskets Construction: Inner Chamber - Heavy gauge corrosion resistant zinc coated galvanized steel. Outer shell - heavy gauge, cold-rolled steel Electrical Requirements: 115 volts, 60 hertz, 1 phase 208 volts, 60 hertz, 1 phase 230 volts, 60 hertz, 1 phase 220 volts, 50 hertz, 1 phase 440 volts, 60 hertz, 1 phase Digital Alarm System: Battery operated alarm system with digital display. Audio and visual display will activate with temperature warm up or loss of power. System includes an audio silence switch and alarm test switch. Accessories: Chart recorder 7 day 6 inch Inventory control systems Porthole access CO2 and LN2 back-up system Stainless steel chambers Racks - Baskets Cold safety gloves Three phase electrical wiring Telephone alarm system Voltage safety system RS232 or RS485 Data Ports Models Available to -40ºC CHEST HORIZONTAL C85-3 C85-5 C85-9 C85-12 C85-14 C85-17 C85-22 C ºC to -80ºC 24 x 12 x 18 (60.9 x 30.5 x 45.7) 30 x 18 x 16 (76.2 x 45.7 x 40.6) 47 x 16 x 20 (119.4 x 40.6 x 50.8) 55 x 19 x 20 (139.7 x 48.3 x 50.8) 62 x 20 x 20 (157.5 x 50.8 x 50.8) 69 x 20 x 21 (175.3 x 50.8 x 50.8) 67 x 19 x 30 (170.2 x 48.3 x 76.2) 67 x 23 x 31 (170.2 x 57.2 x 78.7) 34.5 x 26 x 47 (87.6 x 66 x 119.4) 40.5 x 32 x 47 (102.9 x 81.3 x 119.4) 58 x 29.5 x 47 (147.3 x 74.9 x 119.4) 66 x 32.5 x 48 (167.6 x 82.5 x 121.9) 73 x 34 x 48 (185.4 x 86.3 x 121.9) 81 x 34.5 x 49 (205.7 x 87.6 x 124.4) 98 x 36 x 44 (248.9 x 91.4 x 111.8) 98 x 36 x 44 (248.9 x 91.4 x 111.8) UPRIGHT VERTICAL U85-13 U85-18 U85-22 U85-25 U ºC to -80ºC 20 x 22 x (50.8 x 55.9 x 130) 23 x 26 x (58.4 x 66.1 x 130) 28.5 x 26 x (72.4 x 66.1 x 130) 34 x 25 x (86.4 x 63.5 x 130) 38 x 25 x (96.5 x 63.5 x 130) 36 x 33.5 x 79.5 (91.4 x 85.1 x 201.9) 36.5 x 36.5 x 79.5 (92.7 x 92.7 x 201.9) 42 x 36.5 x 79.5 (106.6 x 92.7 x 201.9) 49.5 x 36.5 x 79.5 (125.7 x 92.7 x 201.9) 53 x 36.5 x 79.5 (134.6 x 92.7 x 201.9) U ºC to -80ºC 42 x 25 x (106.7 x 63.5 x 130) 59.5 x 36.5 x 79.5 (151.1 x 92.7 x 201.9) Spartan Drive, Cincinnati, Ohio 45215, USA Phone: Fax: [email protected] B15-16
3 Specifications MINI FREEZER TO -85 C Capacity Temperature Range Dimensions Exterior W x D x H Interior W x D x H 2 cubic feet. / 56 liters -40 C to -85 C 25 x 26 x x 66 x 97 (cm) 17 x 14 x x 35 x 35 (cm) TEMPERATURE CONTROL Microprocessor control displays set point and chamber temperature. ALARM SYSTEM WITH RELAY The battery operated alarm system will emit an audible and visual alarm signal when there is a mechanical or electrical failure. The alarm has an over and under temperature setting, alarm silencing switch, and battery test switch. Also provided is a relay for remote alarm hook-up. REFRIGERATION SYSTEM A So-Low Cascade system with two hermetic compressors. CFC & HCFC free refrigerants. CONSTRUCTION Chamber is 14 ga. Zinc coated galvanized steel. Exterior is 16 ga. steel. Powder Coated cool gray. VOLTAGE 115 volts, 60 hertz, 1 phase. 15 AMP dedicated circuit required. ETL electrical approval. TECHNICAL SUPPORT Supplied by a Nation-Wide Network of Service Comapnies SO-LOW
4 SO-LOW LAB FREEZERS -20 C TO -45 C RESEARCH - TESTING CLINICAL APPLICATIONS PHARMACY FREEZERS LIFE SCIENCES EPOXY STORAGE Spartan Drive, Cincinnati, Ohio 45215, USA (513) Fax: (513)
5 Lab Freezers -20ºC To -45ºC You Can Count On SO-LOW FREEZERS Undercounter Freezer General Specifications MODEL CU. FT. LITERS TEMPERATURE Performance testing is your assurance of So-Low Lab Freezers dependability, Every freezer is fully tested under the most demanding conditions for seven days. The constant ultra low setpoint operating temperature is guaranteed in warm (+30C) temperature environments. Electrical Approval. So-low Freezers are (ETL) listed and conform to UL Standard The freezers are also certified to Canada/CSA Standard C 22.2 No Efficiency is maintained through optimal removal of BTU s generated within the system. Dependability is backed up by a 12 month warranty. Technical problems are handled by a Nation-Wide-Network of service companies. Large Selection Dependability Efficiency Quality Construction Ease of Operation Low Maintenance Laboratory professionals all over the world have recognized the dependability and efficiency of So-Low Ultra Low Freezers, the first to combine all of these performance features and deliver a level of quality construction, reliability and value unequaled anywhere in the world. Accessories: Chart Recorders: 7 day/6 inch Inventory Control Systems Cold Safety Gloves Telephone Alarm System Voltage Safety System CHEST HORIZONTAL (TO -25ºC) (TO -40ºC) (TO -45ºC) CH25-5 CH25-9 CH40-16 CH25-22 CH40-5 CH45-5 CH43-9 CH40-16 CH ºC to -25ºC 0ºC to -25ºC 0ºC to -25ºC 0ºC to -25ºC 0ºC to -45ºC 0ºC to -43ºC 23 x x 27 (58 x 39 x 69) 36 x 16.5 x 28 (91 x 42 x 71) 48.5 x 20.5 x 27.5 (123 x 52 x 69) 68 x 22 x 26 (173 x 56 x 66) 23 x x 27 (58 x 39 x 69) 23 x x 27 (58 x 39 x 69) 36 x 16.5 x 28 (91 x 42 x 71) 48.5 x 20.5 x 27.5 (123 x 52 x 69) 68 x 22 x 26 (173 x 56 x 66) 28.5 x 22 x 37.5 (72 x 56 x 95) 41.5 x 24.5 x 38 (105 x 62 x 97) 56 x 29 x 38.5 (142 x 73 x 97) x 29.5 x 34.3 (186 x 75 x 87) 28.5 x 22 x 37.5 (72 x 56 x 95) 28.5 x 22 x 37.5 (72 x 56 x 95) 41.5 x 24.5 x 38 (105 x 62 x 97) 56 x 29 x 38.5 (142 x 73 x 97) x 29.5 x 34.3 (186 x 75 x 87) UPRIGHT VERTICAL (TO -40ºC) U40-13 U40-18 U40-22 U40-25 U x 22 x (50.8 x 55.9 x 130) 23 x 26 x (58.4 x 66.1 x 130) 28.5 x 26 x (72.4 x 66.1 x 130) 34 x 25 x (86.4 x 63.5 x 130) 38 x 25 x (96.5 x 63.5 x 130) 36 x 33.5 x 79.5 (91.4 x 85.1 x 201.9) 36.5 x 36.5 x 79.5 (92.7 x 92.7 x 201.9) 42 x 36.5 x 79.5 (106.6 x 92.7 x 201.9) 49.5 x 36.5 x 79.5 (125.7 x 92.7 x 201.9) 53 x 36.5 x 79.5 (134.6 x 92.7 x 201.9) UPRIGHT VERTICAL (TO -30ºC) DHW20-20MDP DHW20-30M DHW30-30MP ºC to -20ºC 0ºC to -20ºC 0ºC to -30ºC 27 x 20 x 57 (68 x 51 x 145) 32 x 22.5 x 65 (81 x 57 x 165) 32 x 22.5 x 65 (81 x 57 x 165) 32 x x 80 (81 x 73 x 203) 35.5 x 35 x 79 (90 x 88 x 200) 35.5 x 35 x 79 (90 x 88 x 200) CHEST HORIZONTAL (TO -40ºC) C40-5 C x 18 x 16 (76.2 x 45.7 x 40.6) 69 x 20 x 21 (175.3 x 50.8 x 50.8) 40.5 x 32 x 47 (102.9 x 81.3 x 119.4) 81 x 34.5 x 49 (205.7 x 87.6 x 124.4) Spartan Drive, Cincinnati, Ohio 45215, USA Phone: Fax: [email protected] B15-16A
6 SO-LOW LAB FREEZERS AND REFRIGERATORS LAB & PHARMACY FREEZERS LAB & PHARMACY REFRIGERATORS CHROMATOGRAPHY REFRIGERATORS FLAMMABLE MATERIAL STORAGE EXPLOSION PROOF / MANUAL DEFROST UNDERCOUNTER FREEZERS / REFRIGERATORS
7 General Specifications MODEL CU. FT./LITERS TEMPERATURE LAB & PHARMACY REFRIGERATORS DH4-10GD DH4-12GD DH4-15SGD DH4-17SGD DH4-23GD DH4-23SD DH4-27GD DH4-27SD DH4-38SGD DH4-45SGD DH4-49GD DH4-49SD DH4-66SGD DH4-74GD DH4-74SD 10 / / / / / / x x (52 x 53 x 96) 21 x x (52 x 53 x 116) 33 x 21 x 40.5 (83 x 53 x 102) 33 x 21 x 46.5 (83 x 53 x 118) 40.5" x 25.5" x 55" (102 x 65 x 140) 49" x 25.5" x 55" (125 x 65 x 140) 72 x 27 x 55 (183 x 68 x 140) 24 x 24 x 65 (60 x 60 x 165) 24 x 24 x 73 (60 x 60 x 185) 36 x 24 x 65 (91 x 60 x 165) 36 x 24 x 71 (91 x 60 x 180) 27 x 32 x 81.5 (68 x 81 x 207) 30" x 32" x 81.5" (76 x 81 x 198) 43.5" x 32" x 81.5" (110 x 81 x 198) 75 x 32 x 81.5 (132 x 81 x 207) 75" x 32" x 81.5" (191 x 81 x 198) ECONOMY LABORATORY REFRIGERATORS EC4-10GD EC4-12GD EC4-23GD EC4-23SD EC4-27GD EC4-27SD EC4-38SGD EC4-45SGD EC4-49GD EC4-49SD EC4-74GD EC4-74SD 10 / / / / x x (52 x 53 x 96) 21 x x (52 x 53 x 116) 40.5" x 25.5" x 55" (102 x 65 x 140) 49" x 25.5" x 55" (125 x 65 x 140) 24 x 26 x 54 (60 x 60 x 137) 24 x 24 x 62 (60 x 60 x 157) 27 x 32 x 81.5 (68 x 81 x 207) 30" x 32" x 81.5" (76 x 81 x 198) 43.5" x 32" x 81.5" (110 x 81 x 198) 75" x 32" x 81.5" (191 x 81 x 198) STAINLESS STEEL LABORATORY REFRIGERATORS DH4-12SDSS DH4-23GDSS DH4-23SDSS DH4-27GDSS DH4-27SDSS DH4-49GDSS DH4-49SDSS DH4-72GDSS DH4-72SDSS 12 / x x (52 x 53 x 116) 24 x 24 x 73 (60 x 60 x 185) CHROMATOGRAPHY REFRIGERATORS DH4-23GDCH DH4-23GDCH-SS DH4-27GDCH DH4-27GDCH-SS DH4-38SGDCH DH4-45SGDCH DH4-49GDCH DH4-49GDCH-SS DH4-74GDCH DH4-74GDCH-SS 38 / / " x 25.5" x 55" (102 x 65 x 140) 49" x 25.5" x 55" (125 x 65 x 140) 27 x 32 x 81.5 (68 x 81 x 207) 30" x 32" x 81.5" (76 x 81 x 198) 43.5" x 32" x 81.5" (110 x 81 x 198) 75" x 32" x 81.5" (191 x 81 x 198) PASS-THRU GLASS DOOR REFRIGERATORS DH4-25PT DH4-50PT DH4-80PT 25 / / / x 28 x 53 (79 x 71 x 134) 49 x (125 x 71 x 134) 75 x 28 x 53 (190 x 71 x 134) 26 x 34 x 82 (66 x 86 x 208) 52 x 34 x 82 (132 x 86 x 208) 78 x 34 x 82 (198 x 86 x 208)
8 General Specifications MODEL CU. FT./LITERS TEMPERATURE LABORATORY FREEZERS DH30-12SDSS DH29-23SD DH30-23SDSS DH30-27SDSS DH29-34SD DH29-46SD DH30-49SDSS DH30-72SDSS DH29-74SD 12 / / / / x x (52 x 53 x 116) 31 x 28 x 60 (79 x 71 x 152) 74" x 28" x 60" (188 x 71 x 152) 24 x 24 x 73 (60 x 60 x 185) 26" x 33.75" x 84.5" (66 x 85 x 215) 26" x 33.75" x 84.5" (66 x 85 x 215) 35 x x 81.5 (89 x 85 x 207) 78" x 33.75" x 84.5" (198 x 85 x 215) LABORATORY GLASS DOOR FREEZERS DH20-23GD DH20-23GDSS DH20-27GD DH20-27GDSS DH20-49GD DH20-49GDSS DH20-72GD DH20-72GDSS 26" x 33.75" x 81.5" (66 x 85 x 198) 26" x 33.75" x 81.5" (66 x 85 x 198) LABORATORY MANUAL DEFROST FREEZERS DHW20-20 DHW20-20MDP DHW20-30 DHW20-30M DHW30-30 DHW30-30MP 20 / / C to -30 C -20 C to -30 C 27" x 20" x 57" (68 x 50 x 145) 27" x 20" x 57" (68 x 50 x 145) 32" x 28.75" x 82" (82 x 73 x 208) 32" x 28.75" x 82" (82 x 73 x 208) 35.75" x 34.25" x 72" (90 x 87 x 183) 35.75" x 34.25" x 79" (90 x 87 x 200) 35.75" x 34.25" x 72" (90 x 87 x 183) 35.75" x 34.25" x 79" (90 x 87 x 200) LABORATORY REFRIGERATOR / FREEZER COMBINATION UNITS DH-20RF DH-48RF DH-70RF 10 / 283 (R) 10 / 283 (F) (R) (F) (R) (F) 2ºC to 8ºC -12ºC to -22ºC 2ºC to 8ºC -12ºC to -22ºC 2ºC to 8ºC -12ºC to -22ºC 28 x 28 x 20 (71 x 71 x 51) 28 x 28 x 20 (71 x 71 x 51) 48 x 28 x 60 (122 x 71 x 155) 33 x x 84.5 (85 x 88 x 214) 52 x x 84.5 (132 x 88 x 214) 78 x x 84.5 (198 x 88 x 214) UNDERCOUNTER FREEZERS MV25-4UCF MV30-4UCF MV23-4UCF MV20-1.5UCF 4.5 / / / / 42 0 C to -25 C 0 C to -30 C -17 C to -23 C -20 C 20" x 19.5" x 24.25" (50 x 49 x 61) 20" x 19.5" x 24.25" (50 x 49 x 61) 19" x 18.25" x 24.75" (48 x 46 x 63) 11.25" x " x 12" (29 x 45 x 30) 24" x 24" x 33" (61 x 61 x 83) 24" x 24" x 33" (61 x 61 x 83) 24" x 24" x 34" (61 x 61 x 86) " x 22" x 24.25" (38 x 56 x 62) UNDERCOUNTER REFRIGERATORS MV4-2UCRDA MV4-2UCRGDDA MV4-6UCRDA MV4-6UCRGDDA MV4-8UCRDA 2.5 / / / / / x19.5 x (45 x 49 x 73) x19.5 x (45 x 49 x 73) 20 x 17 x (50 x 43 x 61) x x 24.5 (51 x 45 x 62) 28 x x 26.5 (71 x 52 x 67) x 23.5 x (60 x 59 x 84) x 25.5 x (60 x 64 x 84) x 24 x 34 (76 x 61 x 86) UNDERCOUNTER REFRIGERATOR / FREEZER COMBINATION UNITS MV18-6UCRF MV18-8UCRF 5.3 / 150 (R).7 / 20 (F) 7.2 (R).7 (F) 1 C to 7 C -18ºC to -9ºC 1 C to 7 C -18ºC to -9ºC 21" x 21" x 28" (53 x 53 x 71) 28 x x 26.5 (71 x 52 x 67) x 24 x 34 (61 x 61 x 86) x 24 x 34 (76 x 61 x 86)
9 General Specifications MODEL CU. FT./LITERS TEMPERATURE 23 x 20 x 46 (58 x 50 x 116) 26 x 17 x 51 (66 x 43 x 129) 27 x 20 x x 51 x 145) 28 x 34 x (71 x 86 x 153) 32 x 32 x (81 x 81 x 167) 32 x 34 x (81 x 86 x 180) 35.75" x 35.5" x 72.5" (90 x 90 x 184) 23 x 20 x 46 (58 x 50 x 116) 26 x 17 x 51 (66 x 43 x 129) 27 x 20 x x 51 x 145) 32 x 22.5 x 13.5 (81 x 57 x 34) 32 x 22.5 x 51.5 (81 x 57 x 130) 28 x 34 x (71 x 86 x 153) 32 x 32 x (81 x 81 x 167) 32 x 34 x (81 x 86 x 180) 35.75" x 35.5" x 72.5" (90 x 90 x 184) x 35.5 x 72.5 (90 x 90 x 184) 23" x 20" x 46" (58 x 50 x 116) 26 x 17 x 51 (66 x 43 x 129) 27 x 20 x x 51 x 145) 28" x 34" x 65.25" (71 x 86 x 165) 32 x 31.5 x (81 x 79 x 179) 32 x 33.5 x 76 (81 x 85 x 193) 35.75" x 36.25" x 77.5" (80 x 92 x 196) 23" x 20" x 46" (58 x 50 x 116) 26" x 17" x 51" (66 x 43 x 129) 27" x 20" x 57" (68 x 51 x 145) 32 x 22.5 x 13.5 (81 x 57 x 34) 32 x 22.5 x 51.5 (81 x 57 x 130) 28" x 33.5" x 65.25" (71 x 85 x 165) 32" x 31.5" x 70.75" (81 x 79 x 179) 32" x 33.5" x 76" (81 x 85 x 193) 35.75" x 36.25" x 77.5" (80 x 92 x 196) x x 77.5 (80 x 92 x 196) FLAMMABLE MATERIAL STORAGE REFRIGERATORS DHH4-14SDFMS 14 / 396 DHH4-17SDFMS 20 / 566 DHH4-20SDFMS DHH4-30SDFMS FLAMMABLE MATERIAL STORAGE FREEZERS DHH20-14SDFMS DHH20-17SDFMS DHH20-20SDFMS DHH20-30SDFMS DHH-30RFFMS 14 / / / 141 (F) 25 / 707 (R) -20 C to -15 C EXPLOSION PROOF STORAGE REFRIGERATORS 14 / 396 DHH4-14SDRX DHH4-17SDRX 20 / 566 DHH4-20SDRX DHH4-30SDRX EXPLOSION PROOF STORAGE FREEZERS -18 C to -25 C 14 / 396 DHH20-14SDFX -18 C to -25 C DHH20-17SDFX -18 C to -25 C 20 / 566 DHH20-20SDFX -18 C to -25 C DHH20-30SDFX 5 / 141 (F) DHH-30RFX 25 / 707 (R) REFRIGERATED INCUBATORS SRI3 SRI21D SRI20 SRI27 3.2/99 17/481 20/566 27/765-10ºC to 45ºC 0ºC to 40ºC -10ºC to 40ºC 5 C to 45 C 16" x 14" x 25" (41 x 36 x 64) 27" x 24" x 58" (69 x 46 x 146) 27 x 24" x 58" (69 x 46 x 146) 30 x 29 x 54 (76 x 74 x 137) 24" x 21" x 33.8" (61 x 53 x 85) 34.5" x 34.5" x 77.5" (87 x 87 x 196) 34.5" x 34.5" x 77.5" (87 x 87 x 196) 36.5 x 35.8 x 77.5 (92 x 90 x 196) GENERAL PURPOSE INCUBATORS SMI2 SMI6 SMI7 SMI11 SMI12 SMI31 SMI /55 6/ / /320 12/ /900 40/ above ambient to 70 C 15" x 14.5" x 15" (38 x 37 x 38) 19" x 20" x 26" (48 x 51 x 66) 24 x 24 x 20 (61 x 61 x 51) 36 x 20 x 27 (91 x 51 x 69) 20" x 20" x 26" (49 x 49 x 56) 33 x 26 x 64 (84 x 66 x 163) 35 x 26 x 76 (89 x 66 x 193) 22" x 22" x 27.3" (55 x 56 x 69) 25.5" x 27" x 38" (64 x 69 x 96) 30 x 31.8 x 32.3 (77 x 80 x 82) 42.5 x 27 x 38 (107 x 69 x 96) 25.5" x 27" x 76" (64 x 69 x 193) 39 x 34 x 75 (98 x 86 x 191) 41.5 x 35 x 87.5 (105 x 88 x 222) 1.8/51 6/170 6/ /159 32/906 40/ / x 15.7 x 12.5 (40 x 40 x 32) 20 x 20 x 26 (52 x 51 x 66) 20.5 x 20 x 25.8 (52 x 50 x 65) 21 x 20 x 24 (52 x 50 x 61) 32 x 26 x 63 (83 x 66 x 160) 35 x 26 x 75.5 (89 x 66 x 192) 43 x 34.5 x 67.5 (109 x 88 x 171) 21 x 22.5 x 27 (52 x 57 x 68) 26 x 26 x 40 (67 x 67 x 101) 26 x 25.5 x 40.3 (66 x 64 x 102) 27 x 28 x 38 (69 x 71 x 95) 39.5 x 33.5 x 75.5 (100 x 86 x 191) 42.5 x 34.5 x 87 (108 x 88 x 221) 51 x 44.8 x 80 (129 x 114 x 203) CO2 INCUBATORS SCO2W SCO6WE SCO5W SCO5A SCO31 SCO40 SCO Spartan Drive, Cincinnati, Ohio 45215, USA Phone: Fax: B15-16
08 FRIDGES & FREEZERS
08-80 C FREEZERS PowerFREEZE TM -86 C Freezers VXE/VXS Series, Jouan VXS490 PowerFREEZE cooling system VXE490 Exclusive PowerFREEZE cooling system in each shelf eliminates freeze-thaw cycles, reduces ice
Freezers - Ultrafreezers. Platilab & Irilab Series
Freezers - Ultrafreezers Platilab & Irilab Series PLATILAB: top security and performances with reliable temperature control. IRILAB: combining the high reliability of PLATILAB with the possibility to store
-86 C ULTRALOW TEMPERATURE FREEZERS. NuAire, Inc. 2100 Fernbrook Lane Plymouth, MN 55447 U.S.A. 763.553.1270 www.nuaire.com
-86 C ULTRALOW TEMPERATURE FREEZERS NuAire, Inc. 2100 Fernbrook Lane Plymouth, MN 55447 U.S.A. 763.553.1270 www.nuaire.com NuAire Glacier -86 C Ultra-low Temperature Freezer NuAire Glacier -86 C Ultra-low
Refrigerators - Freezers. Ekofrigolab & Ekobasic Series
Refrigerators - Freezers Ekofrigolab & Ekobasic Series Angelantoni Life Science S.r.l. manufactures a wide range of refrigerated cabinets and combined refrigerator/freezer cabinets. We offer high reliability
MODEL NU-9728-86 C ULTRALOW TEMPERATURE FREEZERS
POLAR EDITION -86 C ULTRALOW FREEZER MODEL NU-9728-86 C ULTRALOW TEMPERATURE FREEZERS NuAire, Inc. 2100 Fernbrook Lane Plymouth, MN 55447 U.S.A. 763.553.1270 WWW.NUAIRE.COM POLAR EDITION -86 C ULTRALOW
MAC-120HE-01 Air-Cooled Chiller
MAC-120HE-01 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 208/230-1-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-01
Ultra-Low Temperature V.I.P. Series Freezers. Integrated Ultra-Low Temperature Storage Solutions for Biosafety, Security and Performance
Ultra-Low Temperature V.I.P. Series Freezers Integrated Ultra-Low Temperature Storage Solutions for Biosafety, Security and Performance The ultra-low temperature freezer VIP series lineup meets diversifying
PRE-ASSEMBLED REMOTE REFRIGERATION SYSTEMS
NOR-LAKE, INCORPORATED 727 Second Street P.O. Box 248 Hudson, Wisconsin 54016 800-955-5253 715-386-2323 866-961-5253 Parts 800-388-5253 Service 715-386-4291 FAX www.norlake.com Split-Pak Pre-Assembled
Digital Ultra-Low Temperature Freezer. Digital Ultra-Low Temperature Freezer, Dual SHFS TM, Chest Type. Dual SHFS TM, Upright Type
- High Performance Touch-Screen TFT LCD Controller for Ease-of-use (WUF, WUF-D models) - Simplified Hi-Efficiency Freezing System can Freezes down to -86 : realize robust and long life time (WUF, WUF-D
Cold Room & Refrigeration System (Casserole Assembly) No of units: 1
Technical Specifications Cold Room & Refrigeration System (Casserole Assembly) No of units: 1 For chiller storage of all sorts of items Chiller storage temperature: 2-5 C Provides excellent thermal efficiency
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
IV. Rear Mount System
Mobile Climate Control 45 MCC Reference Manual 2014 PN: 89-3069 Rearmount Air Conditioning System Eco RM Capacity, Reliability, and Serviceability MCC Eco RM unit, selected as preferred equipment by leading
IC+ NEW inverter compressor technology delivers energy saving, high performance cooling
-3ºC Biomedical Freezers With Inverter Control KM-MU28H1E / KM-MU9H1E l NEW inverter compressor technology delivers energy saving, high performance cooling l Outstanding reliability and performance for
Conserve O Gram. Cold Storage for Photograph Collections Using Individual Freezer Units. Introduction. Types of Freezers. August 2009 Number 14/11
Conserve O Gram August 2009 Number 14/11 Cold Storage for Photograph Collections Using Individual Freezer Units Introduction Most photograph collections can benefit from cold storage. When collections
BIOMEDICAL REFRIGERATORS
BIOMEDICAL REFRIGERATORS U LT R A L O W F R E E Z E R S - L A B O R AT O R Y, P H A R M A C E U T I C A L A N D M E D I CA L R E F R I G E R AT I O N ARCTIKO CONTROLLER At Arctiko we have the customer
Whynter 62 QT DUAL ZONE PORTABLE FRIDGE / FREEZER
Whynter 62 QT DUAL ZONE PORTABLE FRIDGE / FREEZER MODEL# : FM-62DZ Instruction Manual Congratulations on your new WHYNTER product. To ensure proper operation, please read this Instruction Manual carefully
SAFETY PRECAUTIONS Read all of the instructions before using this appliance. When using this appliance, always exercise basic safely precautions,
SAFETY PRECAUTIONS Read all of the instructions before using this appliance. When using this appliance, always exercise basic safely precautions, including the following: Do not use if the power supply
Thermo Scientific Forma -86 C Chest and Upright Freezers. Sample Storage Products You Can Trust
Thermo Scientific Forma -86 C Chest and Upright Freezers Sample Storage Products You Can Trust 1 Everyday sample storage protection. State-of-the-art, patented refrigerated system improves temperature
Nordic Heat Pump Product Guide
Nordic Heat Pump Product Guide About Maritime Geothermal Maritime Geothermal is a privately owned, Canadian based manufacturer of geothermal heat pumps. We began manufacturing the Nordic line of heat pumps
SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS
SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating
LABORATORY / MEDICINE / PHARMACEUTICAL REFRIGERATORS
TECHNOLOGY FOR LIFE LABORATORY / MEDICINE / PHARMACEUTICAL REFRIGERATORS Biomedical Refrigeration I LR / ML (with solid door) Safe storage of temperature-sensitive preparations at +4 C/ +5 C According
Horizontal Steam Sterilizers. Healthcare Line. Since
Horizontal Steam Sterilizers Healthcare Line Since 1925 Horizontal Steam Sterilizers for Healthcare Applications The Tuttnauer line of healthcare sterilizers are designed for hospital operating rooms,
Commercial Refrigeration Temperature and Defrost Controls
Commercial Refrigeration Temperature and Defrost Controls UNI-LINE PRODUCT KNOWLEDGE 2010 Invensys. All Rights Reserved. The names, logos, and taglines identifying the products and services of Invensys
Split System Cooling Product Data
Split System Cooling Product XL16i 1½ 5 Tons PUB. NO. 22-1890-01 Features and Benefits Climatuff compressor Efficiency up to 16.0 SEER and 9.0 HSPF All aluminum Spine Fin coil WeatherGuard fasteners Quick-Sess
Thermostatic Equipment
Thermostatic Equipment comming soon (06/2015): Climatic Chambers with LED lighting Climatic Chambers with steam humidifier Peltier - Cooled Incubators Refrigerators with back - up system ultra - Low Freezers
HL Series - Commercial Heaters Tankless Water Heating Solutions
HL Series - Commercial Heaters 5-18 kw (17,000-61,400 BTUs) Low flow activation options at.15 and.25 GPM (0.6 and 0.9 L-Min) Certified Lead-Free Design Variable Temp Heat Exchanger Pressure Drop Advantage
The prevailing force in the field. AIR CONDITIONING SOLUTIONS FOR THE PULP AND PAPER INDUSTRY
The prevailing force in the field. AIR CONDITIONING SOLUTIONS FOR THE PULP AND PAPER INDUSTRY About HDT Nordic HDT Global, in business for over 75 years, acquired Nordic Air in 2010. Nordic was founded
SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS
SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES After studying this unit, the reader should be able to explain the purpose of the condenser in a refrigeration system. describe differences
DESIGN STANDARDS SECTION 23 60 00
PART 1 - GENERAL 1.01 Work included: A. Piping, tubing and fittings. B. Piping specialties. C. Special duty valves. D. Refrigerants. E. Chillers. F. Refrigerant monitors. 1.02 General requirements: A.
THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.
THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS. NOT ALL CODES ARE POSSIBLE ON ANY INDIVIDUAL UNIT. IF THE ALARM APPLIES
ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL
RANCO INSTALLATION INSTRUCTIONS ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL Relay Electrical Ratings PRODUCT DESCRIPTION The Ranco ETC is a microprocessor-based family of electronic temperature controls,
Thermo Scientific Heratherm Microbiological Incubators. Safe, easy and efficient
Microbiological Incubators Safe, easy and efficient Microbiological Incubators your samples We are obsessed with sample integrity. Each of our new laboratory microbiological incubators is designed with
DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL
DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL Service Information If service or parts are required, contact the nearest Norcold Service Center. To find an authorized Norcold Service Center
MODEL IX -WAC/HP AIR CONDITIONERS & HEAT PUMPS FOR HIGHLY CORROSIVE & HAZARDOUS AREAS
1.5, 2, 2.5, 3, 3.5, 4, 5 & 6 Ton Industrial Grade Wall Mounted Air Conditioners & Heat Pumps Unit Application Bebco Model IX-WAC/HP Industrial Grade Air Conditioners & Heat Pumps are designed as a total
ECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
SECTION 15732 AIR CONDITIONING UNIT
SECTION 15732 AIR CONDITIONING UNIT PART 1 GENERAL 1.01 SUMMARY A. Section includes: 1. Packaged, split system air conditioning unit No. 1. 1.02 REFERENCES A. Air-Conditioning, Heating, and Refrigeration
SECTION 23 81 43 HEAT PUMPS
SECTION 23 81 43 HEAT PUMPS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop heat pumps. 1.2 REFERENCES A. American Society of Heating, Refrigerating and Air-Conditioning Engineers:
Refrigeration and air-conditioning. Alfa Laval s offering at a glance
Refrigeration and air-conditioning Alfa Laval s offering at a glance At Alfa Laval green is cool Alfa Laval products are also installed on oil platforms, in power plants, onboard ships, in the mechanical
Troubleshooting Your Refrigerator
Troubleshooting Your Refrigerator With conscientious care, a refrigerator will perform for years with little or no repairs. Refrigerators are categorized according to the way frost is removed from them.
Split System Heat Pump Product Data
Split System Heat Pump Product Data XL20i 4TWZ0024, 036, 048 & 060 with ComfortLink II and Charge Assist 2, 3, 4 & 5 Tons PUB. NO. 22-1826-01 Features and Benefits Two Climatuff compressors Efficiency
Instruction manual for Firstline FCS12000CH
Instruction manual for Firstline FCS12000CH Contents Introduction... 2 Safety Awareness... 3 Safety Awareness... 4 Name of Parts... 5 Name of Parts... 6 Remote Controller Preparation... 7 Operation of
Benchtop Test Chambers Temperature and Humidity
Benchtop Test Chambers Temperature and Humidity Compact chambers with extended testing ranges ESPEC's Criterion benchtop chambers offer two sizes and a variety of testing ranges. With many options, they
Blood Bank Refrigerators according to DIN 58371 Blood Plasma Freezers according to DIN 58375
Blood Bank Refrigerators according to DIN 58371 Blood Plasma Freezers according to DIN 58375 1865 Philipp Kirsch establishes the company as a coppersmith firm 1901 Beer cooling cylinders are produced 1927
TECHNICAL DATA E-PRO COLD UNITS Refrigerated glass display units, CDDL, CDD and CDDH series
TECHNICAL DATA E-PRO COLD UNITS Refrigerated glass display units, CDDL, CDD and CDDH series The range of E-Pro cold units includes various types of refrigerated units and worktops. Thanks to the flexible
SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT
SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION A. The Work specified in this Section consists of designing, furnishing and installing factory-assembled
MP-4000 Alarm List (Software version 2.4.3 or later)
Service Bulletin SUBJECT: MP4000 Alarm s BULLETIN: C 100 DATE: June 19, 2013 ALARM LIST Where it is possible the alarm number is kept the same as for MP-3000. MP-3000 holds alarm number from 0 to 127.
Split units TH with hermetic compressors
Split units TH with compressors Refrigeration units in split variant. Available with screw or solder terminal. Condensing unit with sound insulated weatherproof housing for outdoor installation. Split
Split System Heat Pump Product Data
Split System Heat Pump Product Silver 14 4A6H4 1 1 /2-5 Tons PUB. NO. 12-1175-07 Contents Features and Benefits 2 Model Nomenclature 3 General 4 Product Specifications 4 A-weighted Sound Power Level [db(a)]
SECTION 11 78 13 MORTUARY REFRIGERATORS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 11 78 13 MORTUARY REFRIGERATORS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also delete any other item or paragraph not applicable in
26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS.
T H R U - T H E - W A L L A I R C O N D I T I O N E R S 26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS. W A L L M A S T E R T H R U - T H E - W A L L A I R C O N D I T I O N E R
Explosion-Proof Electric Unit Heaters
Type FX4 FX4 Explosion-Proof Electric Air Heaters FX4 heaters are UL listed and/or CSA certified for use in hazardous locations. They are designed for dry indoor industrial applications such as oil refineries,
Laboratory Division. Product Range Cold Storage Clean Air Lyo
Laboratory Division Product Range Cold Storage Clean Air Lyo Laboratory Division Product Range Laminar Flow & Biosafety cabinets Operator, product & environment protection Microbiological safety cabinets
86 C Freezer Accessories. More Choices. Choose from a Wide Selection of Racks, Monitoring Systems and Other New Brunswick Freezer Accessories
86 C Freezer Accessories More Choices Choose from a Wide Selection of Racks, Monitoring Systems and Other New Brunswick Freezer Accessories 2 A Wide Range of Accessories The perfect complement for your
Undercounter & Slimline Cabinet Range HR/LR 120 HRB/LRB120 HR/LR 140 HR/LR 150 HR/LR 200 HR/LR 240 HR/LR 360 HR/LR 410
Undercounter & Slimline Cabinet Range HR/LR 120 HRB/LRB120 HR/LR 140 HR/LR 150 HR/LR 200 HR/LR 240 HR/LR 360 HR/LR 410 CONTENTS PAGE Introduction 1 to 2 2. Controller and operation 3 to 4 3. Controller
Split System Cooling Product Data
Split System Cooling Product Data XR17 4TTR7 2, 3, 4 & 5 Tons PUB. NO. 22-1884-01 Features and Benefits CLIMATUFF 2-stage scroll compressor Efficiency up to 18.0 SEER All Aluminum SPINE FIN coil DURATUFF
Incubator with mechanical convection
BF series 400 Incubators and cooling incubators Incubator with mechanical convection The BINDER incubator of the BF series with mechanical convection is suitable for all gentle incubation applications,
Standard Features: Options:
We offer a large variety of features and options for your convenience! Future Health Concepts, Inc. offers a variety of Blanket and Fluid Warming Cabinets in both standard and custom sizes to meet individual
BR I Blood Bank Refrigerators
Technology for Life Medical SYSTEMS Technology for Life BR I Blood Bank Refrigerators +4 C 292.9707.50 08/2013 BIOMEDICAL REFRIGERATION Innovative and reliable refrigeration solutions compression Refrigerators,
How To Understand Evaporator
SECTION 5 COMMERCIAL REFRIGERATION UNIT 21 EVAPORATORS AND THE REFRIGERATION SYSTEM UNIT OBJECTIVES After studying this unit, the reader should be able to Define high-, medium-, and low-temperature refrigeration.
INSTRUCTION MANUAL FOR RECREATIONAL REFRIGERATOR/FREEZER MODEL
INSTRUCTION MANUAL FOR RECREATIONAL REFRIGERATOR/FREEZER MODEL 15-LITER, 20-LITER, 35-LITER, 45-LITER, 60-LITER & 100-LITER SECTION 1 Basic Operation SECTION 2 Cleaning and Storing SECTION 3 Basic Trouble
Marine Refrigerator/freezer CR 195 & CR 195 Stainless Steel-INOX
Marine Refrigerator/freezer CR 195 & CR 195 Stainless Steel-INOX Installation and operating instructions Indel Marine USA, Inc. 3400 Gateway Drive Unit 107 Pompano Beach, FL 33069 Tel +1 954 984 8448,
AIR-COOLED CONDENSERS Technical Guide
BN-ACCTB0306 March, 2006 AIR-COOLED CONDENSERS Technical Guide Monarch and Ambassador Series TABLE OF CONTENTS Overview... 2, 3 Features & Options... 3, 4 Three Solutions...5 Nomenclature...6 Condenser
Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832)
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Z-Plus Series Temperature/Humidity Chambers Reliability You Expect Features You Want Value You Need Z-Plus chambers
A. Section includes air conditioning units, controls and control panels.
SECTION 23 81 23 - COMPUTER-ROOM AIR-CONDITIONERS PART 1 - GENERAL 1.1 SUMMARY A. Section includes air conditioning units, controls and control panels. 1.2 REFERENCES A. Air-Conditioning, Heating, and
S IJDERS SCIE TIFIC B.V.
LOW TEMPERATURE FREEZERS, -45 C Snijders Scientific manufactures beside Ultra Low Temperature freezers (-86 C) also Low Temperature freezers with a maximum range up to -45 C. These LT upright freezers
innovative comfort solutions
engineering and specifications Guide duct-free air conditioning systems Art cool inverter flex multi-split floor standing ceiling cassette PTAC PTHP through-the-wall innovative comfort solutions 1 AT LG,
Product Data. Split System Cooling 22-1904-1F-EN. March 2015
Product Data Split System Cooling 4TTR4018L1000A 4TTR4024L1000A 4TTR4025L1000A 4TTR4030L1000A 4TTR4031L1000A 4TTR4036L1000A 4TTR4037L1000A 4TTR4042L1000A 4TTR4043L1000A 4TTR4048L1000A 4TTR4060L1000A Note:
WAECO COOLMATIC 2.8 CUBIC FEET 12/24 VOLTS DC & 110 / 220 VOLTS AC BUILT-IN REFRIGERATOR-FREEZER WITH FLUSH MOUNT FRAME
Well after screwing around with the old Norcold refrigerator for the past 2 years I finally decided to search for a replacement. I looked at the Wal-Mart offerings but just did not like the look and feel
ASME Packaged Indirect Fired Water Heater
Utilizes Or HTHW To Heat Domestic Water, Semi-Instantaneous or Storage Type Model BW Features Reliable Only high grade materials used in construction to ensure long operating life Hydrastone cement lining
Submitted to Reference Approval Construction Unit Designation Schedule #
SUBMITTAL AQV09JA High Wall 9,000 Btu/h Heat Pump Nom Cooling Capacity (Btu/h) 9,000 SEER 20.0 Cool Capacity Range (Btu/h) 3,100 to 11,900 Nom Heating Capacity (Btu/h) 11,950 HSPF 10.0 Heating COP 3.7
A GUIDE TO SELECTING YOUR INDUSTRIAL OVEN
A GUIDE TO SELECTING YOUR INDUSTRIAL OVEN Application 1 The first step in selecting an industrial oven is defining the required heat application that your oven will be used for. Heat processing is extensively
Heating oven with mechanical convection
FD series 53 Drying ovens / Heating ovens Heating oven with mechanical convection A BINDER FD series heating oven is always used when fast drying and sterilization is required. Thanks to its fully homogeneous
INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE
INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient
CRAC Precision climate control units for data centres
CRAC Precision climate control units for data centres 2 Rittal Computer Room Air Conditioner The whole is more than the sum of its parts The same is true of Rittal The System. With this in mind, we have
Local Dealer: www.cebrands.com
Local Dealer: C.E. LLC - Miami, FL USA www.cebrands.com Res2012-Rev2 QUALITY YOU CAN FEEL Residential Product Line >TCA7,9 Tempstar SmartComfort TXT + Air Conditioner Featuring The Observer Communication
HOSHIZAKI AMERICA, INC.
Item #40096 10/27/2014 1 HOSHIZAKI AMERICA, INC. Hoshizaki America has built a legacy of quality design, reliability and customer commitment. In our Commercial Series refrigeration line, you ll see solutions
Heating oven with mechanical control
ED series 53 Drying ovens / Heating ovens Heating oven with mechanical control The strength of the BINDER ED series heating oven: routine drying and sterilization applications up to 300 C (572 F). Thanks
FTQ. Daikin Inverter Ducted Heat Pump
FTQ Daikin Inverter Ducted Heat Pump A TRADITIONAL CENTRAL AIR SYSTEM MADE BETTER WITH DAIKIN CONSTANT COMFORT INVERTER TECHNOLOGY. The Daikin Inverter Ducted Heat Pump line is a cost effective alternative
SM6 Series Circuit Breaker Monitors CONSOLIDATED. Electronics, Inc. MONITORING THE FUTURE
Series Circuit Breaker Monitors CONSOLIDATED Electronics, Inc. MONITORING THE FUTURE Why SF Gas Density Monitors? 6 Cut Maintenance Costs Your capital investment may be recovered with the elimination of
Material test chamber with mechanical convection
FP series 400 Material test chambers Material test chamber with mechanical convection A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and
Morrison Bros. Co. General Product Specifications
Morrison Bros. Co. General Product Specifications Tank Mounted Spillbox The spill containment device is manufactured to contain spills and drips that may occur at the fill point on aboveground storage
-86 C Freezer Accessories. New Brunswick Freezer Accessories. A wide selection of racks, monitoring systems and more!
-86 C Freezer Accessories New Brunswick Freezer Accessories A wide selection of racks, monitoring systems and more! A Wide Range of Accessories The Perfect Complement for Your Ultra-Low Temperature Freezer
Nirvana. Cycling Refrigerated Dryers
Nirvana Cycling Refrigerated Dryers Nirvana Cycling Refrigerated Dryers Reliability Is Our Design Ingersoll Rand's Nirvana Cycling Refrigerated Dryer provides reliability like no other dryer in its class:
S G G S G G S G G S G G. FR / MF range. Deep Freezers & Plasma Storage Freezers
FR / MF I Deep Freezers & Plasma Storage Freezers 292.9707.70 09/2015 > Low-temperature storage of plasma and other blood products at 41 C / 35 C > According to DIN 58375 & Medical Device 93/42/EEC BIOMEDICAL
Thermo Scientific Heratherm Microbiological Incubators. Safe,
Thermo Scientific Heratherm Microbiological Incubators Safe, easy and efficient Thermo Scientific Heratherm Microbiological Incubators your samples We are obsessed with sample integrity. Each of our new
Operators manual Basic water heater
Operators manual Basic water heater Isotemp Basic water heater has been designed and produced to ensure that your water heater will give long and trouble free operation for many years. It is important,
VDL 53 - Vacuum drying oven for flammable solvents
Vacuum drying ovens VDL 53 - Vacuum drying oven for flammable solvents The VDL series ensures maximum safety when drying organic solvents in accordance with TÜV/GS guidelines. The interior chamber is designed
3.6 CU.FT. REFRIGERATOR INSTRUCTION MANUAL
3.6 CU.FT. REFRIGERATOR INSTRUCTION MANUAL Model No.: MCBR360W MCBR360B MCBR360S To ensure proper use of this appliance and your safety, please read the following instructions completely before operating
Walk-in Cooler & Freezer Instruction Manual
Walk-in Cooler & Freezer Instruction Manual Technical Guidance for design, installation and maintenance of cold room plant, refrigerated warehouse, cold storage warehouse, walk in cooler & walk in freezer
BUILT-IN WINE & BEVERAGE COOLER WITH DUAL TEMPERATURE ZONES INSTRUCTION MANUAL. Model No.: MCWBC77DZC
BUILT-IN WINE & BEVERAGE COOLER WITH DUAL TEMPERATURE ZONES INSTRUCTION MANUAL Model No.: MCWBC77DZC To ensure proper use of this appliance and your safety, please read the following instructions completely
Installation & operating instructions
Installation & operating instructions Isotherm Cruise & Drawer marine freezers Type: CR 63F INOX, CR 65F, CR 65F INOX, CR 90F, CR 90F INOX, DR 55F INOX Indel Webasto Marine USA, Inc. 3400 Gateway Drive
Sanitary Type Electronic Flow Switches
Industries Pharmaceutical Sanitary Type Electronic Flow Switches Food and Beverage Biotechnology Semiconductor Water Treatment S Series Ameritrol, Inc. Instruments and Controls Features No Moving Parts
Are these noise cancelling devices needed to make your chiller quiet??
Are these noise cancelling devices needed to make your chiller quiet?? Not on this chiller! Some sound barriers should never be broken. Government authorities recommend that exposure to loud noise over
MT I Transport Boxes (Active & Passive)
Medical SYSTEMS MT I Transport Boxes (Active & Passive) 292.9707.75 02/2013 BIOMEDICAL REFRIGERATION Innovative and reliable refrigeration solutions compression Refrigerators, Freezers and Ice Liners Absorption
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W
MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries
A/C-HEATER SYSTEM - AUTOMATIC
A/C-HEATER SYSTEM - AUTOMATIC 1995 Volvo 850 1995-96 Auto. A/C-Heater Systems Volvo 850 * PLEASE READ THIS FIRST * WARNING: To avoid injury from accidental air bag deployment, read and carefully follow
Instructional & Operating Manual
Instructional & Operating Manual For CoolFreeze Series Portable Refrigerators/Freezers CF-18, CF-25, CF-35, CF-40, CF-50, CF-80, CF-110 WAECO USA Clinton, CT www.waecousa.com ! Safety indications in the
ice 3 FLUID TO FLUID HEAT PUMP
ice 3 FLUID TO FLUID HEAT PUMP SUBMITTAL DATA (888) 530-7713 P O Box 5, Wentworth, H 03282 Rev.3 (5-30-14) ice 3, IC-2040 Fluid-to-Fluid R-410a Heat Pump Engineering Guide Specifications General otes:
Professional Kitchens
Professional Kitchens Your premium partner for professional refrigeration Product programme 2011-2012 2000 kwh/year High quality Danish design High reliability The simple to use control system has built-in
HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:
HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER: It is normal for a heat pump to have a build up of white frost on the outside coil during cold damp weather. The