1 STRAMIT RESIDENTIAL FLOOR FRAMING SYSTEM p r o d u c t t e c h n i c a l m a n u a l DFF
2 STRAMIT RESIDENTIAL FLOOR FRAMING SYSTEM A suspended floor design solution for both single and two storey residential construction. C-JOIST IMPORTANT NOTICE AND DISCLAIMER The information contained within this brochure is intended for general use and information only. Before application in a particular situation, Stramit recommends that you obtain appropriate independent qualified expert advice confirming the suitability of product(s) and information in question for the application proposed. While Stramit accepts its legal obligations, be aware however that to the extent permitted by law, Stramit disclaims all liability (including liability for negligence) for all loss and damage resulting from the direct or indirect use, or reliance on, the information provided in this brochure. 2
3 CONTENTS PAGE INTRODUCTION SELECTION AND SPECIFICATION DESIGN AND CONSTRUCTION Design Load Criteria Load Areas Framing Connections and Support Balconies and Verandahs Post/Piers and Bracing INSTALLATION PROCUREMENT ADDITIONAL INFORMATION REFERENCES INTRODUCTION The Stramit Residential Floor Framing system is designed to address the needs of domestic house construction. A wide range of section sizes provides freedom in designing floor joists, bearers for most locations. The Stramit Residential Floor Framing System can easily be adapted to a variety of house designs. In addition, the Stramit Residential Floor Framing system has extended bearer options to provide larger span design possibilities. extended bearer spans available up to 8 metres Stramit C-Joist with (U-Beam shown) Extended Bearer The Stramit Residential Floor Framing System offers joist spans at 450mm centres ( metres) Stramit C-Joist Stramit C-Joist and Bearer U-Beam Extended Bearer The Stramit Residential Floor Framing System is only suitable for use in residential home construction. It is not intended, nor suitable, for use in any form of mezzaine commercial, institutional, industrial, agricultural or any other form of non-residential construction. If in any doubt contact Stramit to confirm the suitability of a given application. Stramit Joist Stramit Bearer 3
4 SELECTION AND SPECIFICATION Termite resistant Non combustible components Lightweight and easy to install Ideal for flat or sloping sites Fast track construction with engineered components Pre-cut and prefabricated components enable speedy construction, even on sloping sites Suitable for use on standard industry pier systems Dimensional stability Achieve true lines without warping Economical in materials and construction Delivers a finish without shrinkage cracks Will not warp or twist and remains stable for the life of the building Dimensions and Mass Table 1 STRAMIT C-Joist & Bearer Dimensions & Mass member section depth width lip thickness mass D W L t mm mm mm mm kg/m J J J J J J J C J Joist J J J J J J J B B B C B Bearer B B B D Stramit C-Bearer W Table 2 Materials Stramit C-Joist and Bearers are cold rolled formed sections manufactured from high strength steel in material thickness ranging from 1.0mm (G550 grade, 550 MPa minimum yield stress material) to 2.4mm (G450 grade, 450MPa minimum yield stress material), with Z350 zinc coating (350grams per square metre minimum coating mass) in accordance with Australian Standard AS1397. Other Stramit accessories, such as FCB3 brackets, extended bearer brackets and lateral end restraints, are made from 300 MPa or 450MPa steel with a minimum glavanised coating of 275 grams per square metre. Tolerances Stramit C-Joists and Bearers are supplied with a length tolerance of +0-10mm. Performance Stramit C-Joists STRAMIT Extended Bearer Range Dimensions & Mass Member Sections* Depth Width Mass D (mm) W (mm) (kg/m) 200x100x4.0 RHS RHS 200x100x6.0 RHS x150x5.0 RHS UB UB 200UB UB UB * sections supplied by others The Stramit Residential Floor Framing System has been designed to NASH Residential and Low-Rise Steel Framing manual - Part 1 (Design Criteria) to meet the performance requirement of the NCC. Use of these provisions reduces the uncomfortable bounce and vibration that may be present in other systems. The product range can be used for both single and two storey construction. Internal bearers or joists do not support any load bearing walls. Deflections under service loads are limited to a minimum of span/500 and 12mm. W L D 4
5 Durability Ground clearance requirements Stramit steel flooring is not intended for use in applications where the clearance above the ground is less than 400mm. A reduction of ground clearance is possible in small localised areas on sloping sites to a minimum of 150mm within 2m of a ventilated external wall. In all cases the subfloor ventilation details should meet the requirements of Part of the National Construction Code, Volume 2. For application requirements regarding location, product, finish, ventilation refer to table 3. Table 3 FLOOR SYSTEM DURABILITY CRITERIA One of the following applicable criteria must be adhered to ensure satisfactory performance of the floor system. The standard system is not suitable for applications closer than 300m to calm still coastal water or closer than 1km to rough active surf. Application >10km from the coast <10km but > 1km from the < 1km but > 300m from & not in a heavy coast & not in a heavy calm still coastal water & industrial area. industrial area. not in a heavy industrial area. Ground Floor Sub-floor can be Sub-floor should be enclosed Sub-floor must be enclosed completely open and incorporate ventilators, or & incorporate ventilators, or Sub-floor painted with etch primer Sub-floor painted with high plus water-based acrylic top coat. build epoxy mastic based system Upper Floor No ceiling lining required If fully enclosed building, If fully enclosed building, of Two Storey no ceiling lining required, or no ceiling lining required, or Building If not fully enclosed, sub-floor If not fully enclosed, sub-floor painted with etch primer plus painted with high build water based acrylic top coat epoxy mastic system Balcony / Provide weather tight Provide weather tight top cover Provide weather tight top Verandah top cover protection, or protection & complete cover protection & complete For open deck or strip encapsulation, or encapsulation, or flooring sub-floor painted Sub-floor painted with etch primer Sub-floor painted with high with etch primer plus water- plus water-based acrylic top coat build epoxy mastic system based acrylic top coat Notes: The information above is current at the time of publication. Please check the NCC and BlueScope website for the latest information and guidance. If uncertain about the use of the system in an aggressive environment, please contact your nearest Stramit office for advice. 5
6 DESIGN AND CONSTRUCTION Consideration of house plans is required when designing the floor system. The Stramit C-Joist system has the extended bearer option. Extended bearers provide design flexibility and allow for large spans to be achieved in areas such as above garages, rumpus, living rooms and balconies. Design Load Criteria The Limit State Method has been used throughout this brochure. Minimum design load and load combinations are generally as per NASH Standard Part 1. Load allowances Floor live load: 1.5 kpa 2.0 kpa - for balcony areas. Concentrated load: 1.8kN Dead load: Self-weight plus partition loads, plus weight of flooring, roof, and walls if applicable. Static and Dynamic serviceability Deflection, D 1 L/500 and D 1 < 12mm load combination: dead load + 100% live load. Deflection, D 2 < 2mm load :1kN. Assumptions Tile roof mass: 92kg/m 2. Metal roof mass: 40.7kg/m 2. Ceiling mass: 10.5kg/m 2. Wall mass: 29.5kg/m 2. Definitions balcony: an external area, one or more metres above ground. All load data has been based on using 18mm fibre cement sheeting as the flooring material; this provides substantial cross bracing whilst maintaining the 2.0kPa live loading requirement. partition loads: weight of non-load bearing walls, floor underlays and floor coverings, ceilings, services through floors, are assumed to be a maximum of 0.5kPa. joist spans: the distance between the end supports of a joist, which is usually the webs of the bearers to which the joist is attached. bearer spans: the centre distance between the piers or posts supporting the bearer. Single-span bearers only have two supports, one at each end, even if there are a series of such bearers in line. Continuous-span bearers have more than two equally-spaced supports. Design Limitations The Stramit C-Joist System is suitable for suspended floor framing in single occupancy buildings which come within the scope of a Class 1a dwelling as defined by NCC. The building should conform to all limitations as set out in Clause 1.2 of AS Floor live load exceeding 1.5kPa (2.0kPa for balconies) requires engineering calculations. Floor concentrated load of more than 1.8kN requires engineering calculations. May not be suitable for heavy items such as water beds, water tanks, large plants or aquariums, heavy gym equipment or pianos etc. Seek engineering advice for such applications. Not suitable for applications closer than 1km to aggressive environments. Connections between extended bearers and the structural elements of the building are the responsibility of the building designer. Stramit C-Joists must be used between bearers, as an in-plane system shown below. The information in this brochure is applicable only to the in-plane system. The use of the products in a joist on bearer configuration can lead to an undesirable transfer of movement-related vibration within and between rooms and is not recommended. Stramit C-Joist Stramit Bearers Stramit Extended Bearer Brackets Stramit C-Joists Extended Bearer Section (by others) Applied Standards AS/NZS 4600 Cold-formed steel structures. NASH Standard, Residential and Low-rise Steel Framing, Part 1 Design Criteria, The design tables include both single and continuous span configurations. 6
7 Load Areas ROOF-LOAD AREA Single or Upper Level of Two Storey Single span bearer - Tables 7 to 10 Continuous span bearer - Tables 11 & 12 roof-load area (tables 7-12) balcony & verandah area (tables 17-18) roof-load area (tables 13-16) non-roof-load area (tables 4-6) roof-load area (tables 13-16) OH roof-load area -single or upper level x Design Tables Data for the design of members can be found in Tables 4 to 18 and for connections and supports in Tables 19 to 24. Non-Roof-Load Areas These are defined as any floor areas within the internal confines of a residential building structure that supports 1.5 kpa live load, 0.5 kpa partition loading and are not supporting load-bearing walls or large concentrated loads (greater than 1.8kN). Internal areas can include bearers or joists at the sides of openings (eg. stairwell) OH ROOF-LOAD AREA Lower Level of Two Storey Single span bearer - Tables 13 & 14 Continuous span bearer - Tables 15 & 16 x NON-ROOF-LOAD AREA Any Floor level Single span bearer - Tables 4 & 5 Continuous span bearer - Table 6 roof-load area -lower level non-roof-load area Roof-Load Areas These are defined as areas that support combined roof, wall and floor loads within the residential building structure. They work as the combined load system of roof and floor areas. Balcony & Verandah Areas These are defined as floor areas that are external to the habitable building structure, and are located one or more metres above the ground. BALCONY AND VERANDAH NON-ROOF-LOAD AREA All Levels Single span bearer - Table 17 Continuous span bearer - Table 18 balcony & verandah area 7
8 NON-ROOF-LOAD AREA STRAMIT BEARERS - SINGLE SPAN Table 4 FLOOR SYSTEM - Non-Roof-Load Areas Maximum Joist Span 1.9mm thick SINGLE SPAN bearers bearer B11519 B18219 B23519 B28319 span J11510 J11512 J11515 J11519 J18210 J18212 J18215 J18219 J18224 J23512 J23515 J23519 J23524 J28319 J28324 <1.2* mm thick SINGLE SPAN bearers bearer B18224 B23524 B28324 span J18210 J18212 J18215 J18219 J18224 J23512 J23515 J23519 J23524 J28319 J28324 <1.4* Notes: only for joists at 450mm centres suitable for 19mm or 22mm thick particleboard floors not suitable for roof loading not suitable to support load bearing walls, or large concentrated load not suitable for balcony areas (*) for bearer of less than that span, or bearers sitting along the span on a bearing wall. extrapolation not permitted deflection L/500 and 12mm 8
9 Table 5 FLOOR SYSTEM - Non-Roof-Load Areas Maximum Joist Span SINGLE SPAN extended range bearers 200 UB 18 bearer span J11510 J11512 J11515 J11519 J18210 J18212 J18215 J18219 J18224 J23512 J23515 J23519 J23524 J28319 J UB 22 bearer span J11510 J11512 J11515 J11519 J18210 J18212 J18215 J18219 J18224 J23512 J23515 J23519 J23524 J28319 J UB 25 bearer span J11510 J11512 J11515 J11519 J18210 J18212 J18215 J18219 J18224 J23512 J23515 J23519 J23524 J28319 J bearer 310 UB 32 span J11510 J11512 J11515 J11519 J18210 J18212 J18215 J18219 J18224 J23512 J23515 J23519 J23524 J28319 J Notes: only for joists at 450mm centres suitable for 19mm or 22mm thick particleboard floors not suitable for roof loading not suitable to support load bearing walls, or large concentrated load not suitable for balcony areas extrapolation not permitted deflection L/500 and 12mm EXTENDED BEARERS - SINGLE SPAN NON-ROOF-LOAD AREA 9
10 NON-ROOF-LOAD AREA STRAMIT BEARERS - CONTINUOUS SPAN Table 6 FLOOR SYSTEM - Non-Roof-Load Areas Maximum Joist Span 1.9mm thick CONTINUOUS SPAN bearers bearer B11519 B18219 B23519 B28319 span J11510 J11512 J11515 J11519 J18210 J18212 J18215 J18219 J18224 J23512 J23515 J23519 J23524 J28319 J28324 <1.2* mm thick CONTINUOUS SPAN bearers bearer B18224 B23524 B28324 span J18210 J18212 J18215 J18219 J18224 J23512 J23515 J23519 J23524 J28319 J28324 <1.4* Notes: only for joists at 450mm centres suitable for 19mm or 22mm thick particleboard floors not suitable for roof loading not suitable to support load bearing walls, or large concentrated load not suitable for balcony areas (*) for bearer of less than that span, or bearers sitting along the span on a bearing wall. extrapolation not permitted deflection L/500 and 12mm 10
11 Table 7 Maximum Bearer Span, Single/Upper Storey Tiled Roof Single Span Bearers B11519 joist span nom B18219 joist span nom B18224 joist span nom Maximum Bearer Span, Single/Upper Storey Tiled Roof Single Span Bearers B23524 joist span nom B28319 joist span B28324 joist span nom STRAMIT BEARERS - SINGLE SPAN TILED ROOF B23519 joist span nom Notes: only for joists at 450mm centres with 19mm or 22mm thick particle board floors not suitable to support other load bearing walls, or large concentrated loads not suitable for balcony areas nom in table above refers to a floor load width less than 500mm linear interpolation is permitted extrapolation not permitted deflection L/500 and 12mm OH y = Roof Load Width = x 2 + OH joist span = y x ROOF-LOAD AREA - SINGLE / UPPER STOREY 11
12 ROOF-LOAD AREA - SINGLE / UPPER STOREY META L ROOF STRAMIT BEARERS - SINGLE SPAN Table 8 Maximum Bearer Span, Single/Upper Storey Metal Roof Single Span Bearers B11519 joist span nom B18219 joist span nom B18224 joist span nom B23519 joist span nom Notes: only for joists at 450mm centres with 19mm or 22mm thick particle board floors not suitable to support other load bearing walls, or large concentrated loads not suitable for balcony areas nom in table above refers to a floor load width less than 500mm linear interpolation is permitted extrapolation not permitted deflection L/500 and 12mm Maximum Bearer Span, Single/Upper Storey Metal Roof Single Span Bearers B23524 joist span nom B28319 joist span B28324 joist span OH y = Roof Load Width = x 2 + OH joist span = y x 12
13 Table 9 Maximum Bearer Span, Single/Upper Storey Tile Roof Single Span Bearers 200x100x4.0 RHS joist span x100x6.0 RHS joist span x150x5.0 RHS joist span Maximum Bearer Span, Single/Upper Storey Tile Roof Single Span Bearers 200UB22.3 joist span UB25.7 joist span UB32.0 joist span EXTENDED BEARERS - SINGLE SPAN TILED ROOF UB18.2 joist span Notes: only for joists at 450mm centres with 19mm or 22mm thick particle board floors not suitable to support other load bearing walls, or large concentrated loads not suitable for balcony areas nom in table above refers to a floor load width less than 500mm linear interpolation is permitted extrapolation not permitted deflection L/500 and 12mm = Roof Load Width = x 2 + OH joist span = y ROOF-LOAD AREA - SINGLE / UPPER STOREY 13
14 ROOF-LOAD AREA - SINGLE / UPPER STOREY META L ROOF EXTENDED BEARERS - SINGLE SPAN Table 10 Maximum Bearer Span, Single/Upper Storey Metal Roof Single Span Bearers 200x100x4.0 RHS joist span x100x6.0 RHS joist span x150x5.0 RHS joist span UB18.2 joist span Notes: only for joists at 450mm centres with 19mm or 22mm thick particle board floors not suitable to support other load bearing walls, or large concentrated loads not suitable for balcony areas nom in table above refers to a floor load width less than 500mm linear interpolation is permitted extrapolation not permitted deflection L/500 and 12mm Maximum Bearer Span, Single/Upper Storey Metal Roof Single Span Bearers = Roof Load Width = x 2 + OH joist span = y 200UB22.3 joist span UB25.7 joist span UB32.0 joist span
15 Table 11 Maximum Bearer Span, Single/Upper Storey Tile Roof Continuous Span Bearers B11519 joist span nom B18219 joist span nom B18224 joist span nom Maximum Bearer Span, Single/Upper Storey Tile Roof Continuous Span Bearers B23524 joist span nom B28319 joist span B28324 joist span STRAMIT BEARERS - CONTINUOUS SPAN TILED ROOF B23519 joist span nom Notes: only for joists at 450mm centres with 19mm or 22mm thick particle board floors not suitable to support other load bearing walls, or large concentrated loads not suitable for balcony areas nom in table above refers to a floor load width less than 500mm linear interpolation is permitted extrapolation not permitted deflection L/500 and 12mm = Roof Load Width = x 2 + OH joist span = y ROOF-LOAD AREA - SINGLE / UPPER STOREY 15
16 ROOF-LOAD AREA - SINGLE / UPPER STOREY META L ROOF STRAMIT BEARERS - CONTINUOUS SPAN Table 12 Maximum Bearer Span, Single/Upper Storey Metal Roof Continuous Span Bearers B11519 joist span nom B18219 joist span nom B18224 joist span nom B23519 joist span nom Notes: only for joists at 450mm centres with 19mm or 22mm thick particle board floors not suitable to support other load bearing walls, or large concentrated loads not suitable for balcony areas nom in table above refers to a floor load width less than 500mm linear interpolation is permitted extrapolation not permitted deflection L/500 and 12mm Maximum Bearer Span, Single/Upper Storey Metal Roof Continuous Span Bearers B23524 joist span nom B28319 joist span B28324 joist span OH y x = Roof Load Width = x 2 + OH joist span = y 16
17 Table 13 Maximum Bearer Span, Lower Level of 2 Storey Tile Roof Single Span Bearers 200x100x4.0 RHS upper level joist span + lower level joist span x100x6.0 RHS upper level joist span + lower level joist span x150x5.0 RHS upper level joist span + lower level joist span Maximum Bearer Span, Lower Level of 2 Storey Tile Roof Single Span Bearers 200UB22.3 upper level joist span + lower level joist span UB25.7 upper level joist span + lower level joist span UB32.0 upper level joist span + lower level joist span EXTENDED BEARERS - SINGLE SPAN TILED ROOF UB18.2 upper level joist span + lower level joist span Notes: only for joists at 450mm centres with 19mm or 22mm thick particle board floors not suitable to support other load bearing walls, or large concentrated loads not suitable for balcony areas nom in table above refers to a floor load width less than 500mm linear interpolation is permitted extrapolation not permitted deflection L/500 and 12mm OH y = Roof Load Width = x 2 + OH upper level joist span = x lower level joist span = y x ROOF-LOAD AREA - LOWER STOREY 17
18 ROOF-LOAD AREA -LOWER STOREY META L ROOF EXTENDED BEARERS - SINGLE SPAN Table 14 Maximum Bearer Span, Lower Level of 2 Storey Metal Roof Single Span Bearers 200x100x4.0 RHS upper level joist span + lower level joist span x100x6.0 RHS upper level joist span + lower level joist span x150x5.0 RHS upper level joist span + lower level joist span UB18.2 upper level joist span + lower level joist span Notes: only for joists at 450mm centres with 19mm or 22mm thick particle board floors not suitable to support other load bearing walls, or large concentrated loads not suitable for balcony areas nom in table above refers to a floor load width less than 500mm linear interpolation is permitted extrapolation not permitted deflection L/500 and 12mm Maximum Bearer Span, Lower Level of 2 Storey Metal Roof Single Span Bearers 200UB22.3 upper level joist span + lower level joist span UB25.7 upper level joist span + lower level joist span UB32.0 upper level joist span + lower level joist span OH y x = Roof Load Width = x 2 + OH upper level joist span = x lower level joist span = y 18
19 Table 15 Maximum Bearer Span, Lower Level of 2 Storey Tile Roof Continuous Span Bearers B11519 upper level joist span + lower level joist span nom B18219 upper level joist span + lower level joist span nom B18224 upper level joist span + lower level joist span nom Maximum Bearer Span, Lower Level of 2 Storey Tile Roof Continuous Span Bearers B23524 upper level joist span + lower level joist span nom B28319 upper level joist span + lower level joist span B28324 upper level joist span + lower level joist span STRAMIT BEARERS - CONTINUOUS SPAN TILED ROOF B23519 upper level joist span + lower level joist span nom Notes: only for joists at 450mm centres with 19mm or 22mm thick particle board floors not suitable to support other load bearing walls, or large concentrated loads not suitable for balcony areas nom in table above refers to a floor load width less than 500mm linear interpolation is permitted extrapolation not permitted deflection L/500 and 12mm OH y = Roof Load Width = x 2 + OH upper level joist span = x lower level joist span = y x ROOF-LOAD AREA - LOWER STOREY 19
20 ROOF-LOAD AREA -LOWER STOREY META L ROOF STRAMIT BEARERS - CONTINUOUS SPAN Table 16 Maximum Bearer Span, Lower Level of 2 Storey Metal Roof Continuous Span Bearers B11519 upper level joist span + lower level joist span nom B18219 upper level joist span + lower level joist span nom B18224 upper level joist span + lower level joist span nom B23519 upper level joist span + lower level joist span nom Notes: only for joists at 450mm centres with 19mm or 22mm thick particle board floors not suitable to support other load bearing walls, or large concentrated loads not suitable for balcony areas nom in table above refers to a floor load width less than 500mm linear interpolation is permitted extrapolation not permitted deflection L/500 and 12mm Maximum Bearer Span, Lower Level of 2 Storey Metal Roof Continuous Span Bearers B23524 upper level joist span + lower level joist span nom B28319 upper level joist span + lower level joist span nom B28324 upper level joist span + lower level joist span OH y = Roof Load Width = x 2 + OH upper level joist span = x lower level joist span = y x 20
21 Table 17 FLOOR SYSTEM - Non-Roof - BALCONY Loads Maximum Joist Span 1.9mm thick SINGLE SPAN bearers single bearer B11519 B18219 B23519 B28319 span J11510 J11512 J11515 J11519 J18210 J18212 J18215 J18219 J18224 J23512 J23515 J23519 J23524 J28319 J28324 <1.2* mm thick SINGLE SPAN bearers single bearer B18224 B23524 B28324 span J18210 J18212 J18215 J18219 J18224 J23512 J23515 J23519 J23524 J28319 J28324 <1.4* STRAMIT BEARERS - SINGLE SPAN Notes: only for joists at 450mm centres suitable for 15mm thick fibre-cement flooring. not suitable for roof loading not suitable to support load bearing walls, or large concentrated load (*) for bearer of less than that span, or bearers sitting along the span on a bearing wall. extrapolation not permitted deflection L/500 and 12mm BALCONY AREA 21
22 BALCONY AREA STRAMIT BEARERS - CONTINUOUS SPAN Table 18 FLOOR SYSTEM - Non-Roof- BALCONY Loads Maximum Joist Span 1.9mm thick CONTINOUS SPAN bearers bearer B11519 B18219 B23519 B28319 span J11510 J11512 J11515 J11519 J18210 J18212 J18215 J18219 J18224 J23512 J23515 J23519 J23524 J28319 J28324 <1.2* mm thick CONTINOUS SPAN bearers bearer B18224 B23524 B28324 span J18210 J18212 J18215 J18219 J18224 J23512 J23515 J23519 J23524 J28319 J28324 <1.4* Notes: only for joists at 450mm centres suitable for 15mm thick fibre-cement flooring. not suitable for roof loading not suitable to support load bearing walls, or large concentrated load (*) for bearer of less than that span, or bearers sitting along the span on a bearing wall. extrapolation not permitted deflection L/500 and 12mm 22
HOPLEYS OPENWEBSTEELJOISTS
Design Aid Manual Now also includes Letter of Certification & Bearer Span Table HOPLEYS OPENWEBSTEELJOISTS 2...has over 60 years experience and a respected reputation in Sheet Metal fabrication and associated
More informationTimber Decks. Technical Note. March 2007
Timber Decks Technical Note. March 2007 This Technical Note contains general information for residential timber decks and floor frame structures for veranda s, patios etc which are exposed to the weather.
More informationSTRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM
Chapter 9 STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM 9.1 BACKGROUND Steel is widely used in the construction of multi-storey buildings. However, steel construction is seldom used and is traditionally
More informationDecember 2013. J-Ply Roofing, Flooring and Decking
December 2013 J-Ply Roofing, Flooring and Decking Introduction J-Ply plywood is manufactured in New Zealand by Juken New Zealand Limited (JNL) and marketed by New Zealand Wood Products Limited. The J-Ply
More informationCOMMONLY USED RESIDENTIAL BUILDING CODES
COMMONLY USED RESIDENTIAL BUILDING CODES INTERNATIONAL RESIDENTIAL CODE (2009) form revised 5/10 FOUNDATION 1. DESIGN OF FORMWORK. Section 1906.1 IBC 2009, Section R404.1.2.3.6 IRC 2009, ACI 318 Section
More informationKnauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap
Tile Backing Will not deteriorate in water Easy to score and snap Resistant to mould and mildew Knauf Aquapanel Interior Cement board for wet areas Knauf Aquapanel Interior Cement Board Drywall for Wet
More informationPART 1 GENERAL 1.1 SECTION INCLUDES
J-1 Section 09110 Long Form Specification INTERIOR METAL STUD FRAMING This section includes lightweight, usually 0.036 inch (0.9 mm) thick or lighter, non-axial load bearing metal stud framing including
More informationSTANDARD OPEN PATIO COVER
STANDARD OPEN PATIO COVER BUILDING & SAFETY DIVISION 201 E. LA HABRA BLVD. LA HABRA, CA 90631 62-90-9710 Call Before You Dig 1-800-227-2600 PLEASE NOTE: This information Bulletin is made available to assist
More informationTECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE
TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE TECHNICAL SPECIFICATION PART 8000 - PRECAST CONCRETE TABLE OF CONTENTS Item Number Page 8100 PRECAST CONCRETE CONSTRUCTION - GENERAL 8-3 8101 General
More informationAsphalt Shingle Application Requirements
Alberta Allied Roofing Association Asphalt Shingle Application Requirements Section 1 Roof Decks 1.1 General Asphalt Shingles are not permitted to be installed directly over rigid insulation. When Asphalt
More informationDetailing of Reinforcment in Concrete Structures
Chapter 8 Detailing of Reinforcment in Concrete Structures 8.1 Scope Provisions of Sec. 8.1 and 8.2 of Chapter 8 shall apply for detailing of reinforcement in reinforced concrete members, in general. For
More informationCERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011
CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS
More informationCH. 2 LOADS ON BUILDINGS
CH. 2 LOADS ON BUILDINGS GRAVITY LOADS Dead loads Vertical loads due to weight of building and any permanent equipment Dead loads of structural elements cannot be readily determined b/c weight depends
More informationSuperform Products Ltd.
TYPICAL CORNER REINFORCING NOTE : SEE ENGINEERED REBAR SCHEDULES SUPPLIED BY THE MANUFACTURER STEEL REINFORCEMENT WALL CORNER 90 Copyright 2012 Sept. 2012 5.1.1 Rebar Spacing 6" 12" Max. Load LB./FT. 2000
More informationCertification: Building Plans Examiner. Exam ID: B3
Certification: Building Plans Examiner Exam ID: B3 Scope: A Building Plans Examiner will be responsible for reviewing submitted plans to determine if they meet the requirements of the various Building
More informationTimber Frame Construction
Timber Frame Construction Introduction Design and Detailing What is timber? Failure modes History of timber frame construction Forms of timber frame construction Live and dead loads Wind loads Roof construction
More informationConnection Solutions
Connection Solutions DESIGN BUILD SYSTEM Connection Solutions for Cold formed Steel Construction Complies with; AS/NZS 4600:2005 AISI S100:2007 AS/NZ 1397 ASTM A653 DESIGN & BUILD SYSTEM FRAMECAD Construction
More informationPartitioning & Ceiling Product Information
Partitioning & Ceiling Product Information tel + 44 (0) 1384 412448 fax + 44 (0) 1384 4494 email enquiries@drywallsteelsections.co.uk web www.drywallsteelsections.co.uk tel + 44 (0) 1384 412448 fax + 44
More informationTECHNICAL RECOMMENDATION
TECHNICAL RECOMMENDATION NO: 9 DESIGN OF LIGHT TIMBER FRAMED WALLS AND FLOORS FOR FIRE RESISTANCE Peter Collier Contents Design of Light Timber Framed Walls and Floors for Fire Resistance Relevance Acceptance
More informationWorkSafe Guidance Document FALL PROTECTION IN RESIDENTIAL CONSTRUCTION
WorkSafe Guidance Document FALL PROTECTION IN RESIDENTIAL CONSTRUCTION WorkSafe Guidance Document Fall Protection in Residential Construction Table of Contents Executive Summary... 1 Introduction... 1
More informationPost and Beam Construction
Post and Beam Construction A Presentation By the Canadian Wood Council Canadian Conseil Wood canadien Council du bois Early settlers introduced the concept of post and beam construction in North America
More information4. ANCHOR BOLTS AND STRAPS a. ½" anchor bolts shall be embedded 7" into concrete a maximum of 6' on center and 12" from corners and ends of plates.
GENERAL CODE REQUIREMENTS (BASEMENTS) 1. FOOTINGS a. Footings shall be below frost line depth (42"). b. For an 8" foundation wall, footings shall be no less than 8" deep and 16" wide. c. Steel reinforcement
More informationRESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings
More informationPERGOLAS AND CARPORTS
TECHNICAL DATA SHEET ISSUED BY TIMBER QUEENSLAND PERGOLAS AND CARPORTS RECOMMENDED PRACTICE // MARCH 2014 19 This data sheet contains Timber Queensland s recommendations for attached and detached timber
More informationRockwool Flexi Insulation Application Guide
Pitched roof Rafters InterMediate floors INTERNAL partitions external Framed walls separating floors Separating Walls Rockwool Flexi Insulation Application Guide Ground floor The perfect fit for any framed
More informationDESIGN OF SLABS. 3) Based on support or boundary condition: Simply supported, Cantilever slab,
DESIGN OF SLABS Dr. G. P. Chandradhara Professor of Civil Engineering S. J. College of Engineering Mysore 1. GENERAL A slab is a flat two dimensional planar structural element having thickness small compared
More informationMANUFACTURED HOUSING USED AS DWELLINGS
MANUFACTURED HOUSING USED AS DWELLINGS SECTION AE101 SCOPE AE101.1 General. These provisions shall be applicable only to a manufactured home used as a single dwelling unit and shall apply to the following:
More informationScope of EN 1090-1 Clarification Document
Scope of EN 1090-1 Clarification Document This document has been submitted to the European Commission as the UK view on the scope of EN 1090-1. After discussions, including with the European Technical
More informationThe WANZ Guide to Window Installation
The WANZ Guide to Window Installation as described in E2/AS1 Amendment 5 Ver. 1.1 Page 2 of 74 Contents Overview Page 5 Objective Page 5 Scope Page 5 Opening Preparation Page 7 Step P1 Preliminary Check
More informationtechnology UICK progressive sustainable any design, any shape, any colour, anywhere you like!
uality using advanced building technology UICK uality innovative progressive sustainable any design, any shape, any colour, anywhere you like! 2 NicheQ is an award winning progressive and innovative builder
More informationHOUSING STANDARDS POLICY TRANSITION STATEMENT IMPLEMENTATION: OCTOBER 2015. May 2015
HOUSING STANDARDS POLICY TRANSITION STATEMENT IMPLEMENTATION: OCTOBER 2015 May 2015 MAYOR OF LONDON Housing Standards: Transition Policy Statement. On 25 March 2015 through a written ministerial statement,
More informationBuilding Construction. Lightweight construction. Conventional Construction
Ventilation 53 Building Construction The firefighter s ability to safely and efficiently ventilate a building through its roof will depend to some degree on the firefighter s understanding of roof construction.
More informationUnderstanding Raised Floor Systems for the Specifier (2008)
Understanding Raised Floor Systems for the Specifier (2008) The Access Flooring Company Unit 4 Norton House Fircroft Way Edenbridge Kent TN8 6EL Tel: 0870 350 0415 Fax: 0870 350 0425 Website: www.accessflooring.com
More informationRESIDENTIAL MASONRY A BEST PRACTICES GUIDE
RESIDENTIAL MASONRY A BEST PRACTICES GUIDE Build With Brick Build With Boral CONTENTS BRICK :01 MASONRY CEMENT :03 MASONRY SAND :04 WALL TIES :05 STEEL LINTELS :07 DRAINAGE WALL SYSTEM :09 FLASHING :11
More information9.8.1.1. General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and guards.
Section 9.8. Stairs, Ramps, Handrails and Guards 9.8.1. Application 9.8.1.1. General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and
More informationGuidance on loft conversions in two-storey houses
Guidance on loft conversions in two-storey houses Technical guidance for building control surveyors, designers and installers 01 Guidance on loft conversions in two-storey houses Technical guidance for
More informationPOST AND FRAME STRUCTURES (Pole Barns)
POST AND FRAME STRUCTURES (Pole Barns) Post and frame structures. The following requirements serve as minimum standards for post and frame structures within all of the following structural limitations:
More informationB. Related categories: The following categories contain requirements that relate to this section:
ORIENTED STRAND BOARD PART I. - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply
More informationLight Steel Modular Construction
Technical Information Sheet ED014 Light Steel Modular Construction R M Lawson BSc PhD CEng MICE MIStructE MASCE ACGI This Information Sheet reviews the various forms of building modules constructed using
More informationWe care about. Environmentally-Friendly Building Products from Renewable Resources. natural building products. Product range overview
http://upload.wikimedia.org/wikipedia/commons/a/ae/flag_of_the_united_kingdom.svg.0.0 :8 Seite von Environmentally-Friendly Building Products from Renewable Resources Product range overview We care about
More informationInsulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panels KS1000 RW
Insulated Roof & Wall Panels Trapezoidal Insulated Roof Panels KS1000 RW Overview Kingspan roof panel systems present a superior system compared to conventional multi-part site assembled systems. They
More informationOWAplan1. The seamless acoustic ceiling. Pure acoustics. Pure design.
OWAplan1 The seamless acoustic ceiling. Pure acoustics. Pure design. 3 Perspectives of freedom OWAplan It is time for a new way of thinking, for a new kind of freedom in room design, for taking a different
More informationExcerpts from the Canadian National Building Code (NBC)
Excerpts from the Canadian National Building Code (NBC) Reproduced here with Permission of the Copyright Owner, the National Research Council of Canada, Institute for Research in Construction. For more
More informationWe re about to build.
We re about to build. Get out there boys! every new home is a possible new dinner menu! What do we need to know about dealing with termites? A Managed Approach is Best! There are more than three hundred
More informationdomestic structure SBSG 2007 ANNEX C
domestic structure SBSG 2007 ANNEX C Small buildings structural guidance 1.A General 1.B Stability 1.C Foundations 1.D Masonry walls 1.E Timber frame walls 1.F Timber floor and roof members contents domestic
More informationDevelopment Services Department Building Permit & Inspection Services Shed and Garage Construction Guide for Detached and Semi-Detached Dwellings
Development Services Department Building Permit & Inspection Services Shed and Garage Construction Guide for Detached and Semi-Detached Dwellings H:/forms/handouts/bldg071.docx Shed and Garage Construction
More informationThe Kingspan Insulation Price List 1 st January 2013
Insulation The Kingspan Insulation Price List 1 st January 2013 FOR BUILDING FABRIC INSULATION, CAVITY CLOSERS AND MEMBRANES Visit our website: www.kingspaninsulation.co.uk Low Energy - Low Carbon Buildings
More informationISO Types 1-6: Construction Code Descriptions
ISO 1 Frame (combustible walls and/or roof) Class 1B Buildings where the exterior walls are wood or other combustible materials, including construction where the combustible materials are combined with
More informationBuilding Code Clarifications - 7. Fire Resistance
Building Code Clarifications - 7. Fire Resistance 7.1 (15-12-030) Use of combustibles in Type III construction roof assemblies Code Section (15-12-030) Use of Combustibles was revised on May 17, 2000,
More informationChapter 6 ROOF-CEILING SYSTEMS
Chapter 6 ROOF-CEILING SYSTEMS Woodframe roof-ceiling systems are the focus of this chapter. Cold-formed steel framing for a roof-ceiling system also is permitted by the IRC but will not be discussed;
More informationInstallation Instructions
Installation Instructions Pedestal Models FS 500 LE FS 800 LE Insert Models IS 500 LE IS 800 LE Pecan Engineering Pty Ltd 13 Acorn Road Dry Creek South Australia 5094 Email info@pecan-eng.com.au Phone:
More informationRESIDENTIAL WOOD DECKS
RESIDENTIAL WOOD DECKS 1 A Building Permit is required for the construction of a wood deck where the deck is more than 600 mm above grade at any point. Definition: For the purposes of this pamphlet, a
More informationYEAR TRANSFERRABLE TANALISED 25 YEAR TERMITE RESISTANT* STRUCTURAL TIMBER AND WOOD PRODUCTS GUARANTEE
TRANSFERRABLE TANALISED 25 TERMITE RESISTANT* STRUCTURAL TIMBER AND WOOD PRODUCTS GUARANTEE Thank you for selecting Tanalised termite resistant* structural timber and wood products for your new home or
More informationPreformed Metal Roofing and Siding
Page -1-1. GENERAL 1.1. Description This specification along with the drawings covers the furnishing of all material, products, equipment, accessories, tools, services, transportation, labor and supervision
More informationH:\forms\handouts\bldg049 1 of 11 Revised Mar 2/15/dh
Accessory Apartment Construction Guide For Single Detached Dwelling and Semi-Detached Dwellings that have been in existence for at least five (5) years Notes: Buildings that are less than five (5) years
More informationEnergy Company Obligation (ECO): Technical Monitoring Questions
Energy Company Obligation (ECO) Technical Monitoring Questions v1 30/05/2013 Energy Company Obligation (ECO): Technical Monitoring Questions Under ECO suppliers are required to instruct suitably qualified
More informationGood Craftsmanship Guide. Carpentry and Joinery- Carcassing
Good Craftsmanship Guide Carpentry and Joinery- Carcassing Introduction This Good Craftsmanship Guide highlights key problems with the major elements of Carpentry and Joinery - Carcassing, and gives guidance
More informationGENERAL + MEANS OF ESCAPE (Part One) By Mdm Eng Yew Hoon (SIA)
GENERAL + MEANS OF ESCAPE (Part One) By Mdm Eng Yew Hoon (SIA) Chapter 1 : Definitions clause 1.2.10 : circulation space OLD CLAUSE A space mainly used as means of access between a room or protected shaft
More informationPlanning Information. Passenger and Freight Elevators.
A company of ThyssenKrupp Elevator Thyssen Aufzüge tk This planning information will give you an overview of the most important planning criteria of passenger and freight elevators. However you should
More informationDocument type: Practice Note Title: External and internal membranes Document number: AC2234 Version: 5. 1. Purpose
Document type: Practice Note Title: External and internal membranes Document number: AC2234 Version: 5 1. Purpose The purpose of this practice note is to address the incidence of deck and roof membrane
More informationQuality Regulations for Profiles
Quality Regulations for Profiles September 2010 Quality Regulations for Profiles Page 2/42 Contents Preface... 4 1. Terms and Definitions... 5 1.1 Third parties... 5 1.2 Independent laboratories... 5 1.3
More information8 EXTRA LIGHT GRC SANDWICH ELEMENTS FOR ROOFING IN INDUSTRIAL BUILDINGS
8 EXTRA LIGHT GRC SANDWICH ELEMENTS FOR ROOFING IN INDUSTRIAL BUILDINGS MARICA DELLA BELLA and DIEGO CIAN Precompressi Centro Nord S.p.A., Italy SUMMARY: Secondary roofing elements, complementary to the
More informationPROJECT TITLE : 2-STOREY RESIDENCE LOCATION : ALONG DAANG HARI,MOLINO.BACOOR,CAVITE OWNER : CUEVASVILLE REALTY
PROJECT TITLE : 2-STOREY RESIDENCE LOCATION : ALONG DAANG HARI,MOLINO.BACOOR,CAVITE OWNER : CUEVASVILLE REALTY GENERAL SPECIFICATIONS These specifications are intended to cover the construction of the
More informationFinal inspections are completed by site visit only. Access to fenced yards shall be planned.
ROOFING RESIDENTIAL BUILDING INSPECTIONS DEPARTMENT www.ci.blaine.mn.us This handout is intended only as a guide and is based in part on the 2015 Minnesota State Building Code, Blaine City ordinances,
More informationHIGH LEVEL SEISMIC UPGRADE COST ESTIMATE FOR CENTRE BLOCK, PARLIAMENT HILL
HIGH LEVEL SEISMIC UPGRADE COST ESTIMATE FOR CENTRE BLOCK, PARLIAMENT HILL Prepared for: Public Works and Government Services Canada Parliamentary Precinct Branch Prepared by: Halsall Associates 210 Gladstone
More information0331 Brick and block construction
0331 BRICK AND BLOCK CONSTRUCTION This worksection has been written for Class 1 and 10a buildings that fully conform to the scope of AS 4773.1. If the works include isolated structures, (totally separate
More informationRESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS
RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS The following guidelines are intended to assist with the permit acquisition process with regard to Plumbing Alterations. Not all information, or additional
More informationCost Guide MARKET SUMMARY OVERVIEW REPAIRS AND MAINTENANCE ELECTRICAL ROOFING & ROOF DRAINAGE (UP TO TWO STOREYS; FIXED TO EXISTING ROOF FRAME)
Cost Guide < 1 > MARKET SUMMARY OVERVIEW Low interest rates and competitive construction pricing makes now a great time to renovate or build a new home. Interest rates are at historic lows and can be fixed
More informationWELAND TERMINOLOGY LOAD BEARING BAR CROSS BAR GRATING TYPE SAF MESH OPENING GRATING. LENGTH, SPAN WIDTH or LENGTH OF LOAD BAR GRATING
GRATING Page Terminology 6-7 Pedestrian Walkway Multipanels from Stock 8-13 Duckboard 13 Vehicular Multipanels with Load Tables 14-15 Kerb Angle Frames 16-17 Entrance Mats 18-20 Special Grating 22 Mesh
More informationMEZZANINE SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE 1.2 APPROVED MANUFACTURER 1.3 REGULATORY ORGANIZATIONS AND GROUPS 1.4 QUALITY ASSURANCE
MEZZANINE SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE This specification is intended to describe the general requirements applicable to a proper structural mezzanine design. In addition, it is to serve as
More informationFormwork for Concrete
UNIVERSITY OF WASHINGTON DEPARTMENT OF CONSTRUCTION MANAGEMENT CM 420 TEMPORARY STRUCTURES Winter Quarter 2007 Professor Kamran M. Nemati Formwork for Concrete Horizontal Formwork Design and Formwork Design
More informationHS-Steel-Classic. Curing chambers for the concrete block industry in a proven steel version
ANLAGENTECHNIK HS-Steel-Classic Curing chambers for the concrete block industry in a proven steel version + special galvanising + simple assembly due to snap-in connections and building kit system We build
More informationPB301 July 2009. Lightweight Building Solutions. Bushfire Protection. www.boral.com.au/bushfireprotection
PB301 July 2009 Lightweight Building Solutions Bushfire Protection www.boral.com.au/bushfireprotection Attached or adjacent within 6m roofed structures such as garages, carports, verandas and the like,
More informationsound reduction systems for commercial, educational and industrial environments
sound reduction systems for commercial, educational and industrial environments Tel: +44 ()14 3874 Fax: +44 ()14 38957 E-mail: info@soundreduction.co.uk Web: www.soundreduction.co.uk soundblocker Acoustic
More informationFCA CARPENTRY & JOINERY THEORY. 10 SIMPLE ROOF CONSTRUCTION Part 2
CARPENTRY & JOINERY FCA CARPENTRY & JOINERY THEORY 10 SIMPLE ROOF Double Roofs A double roof is a roof whose rafters are of such a length that they require an intermediate support. This support is usually
More informationStandards & Tolerances Guide
Standards & Tolerances Guide QUEENSLAND FEBRUARY 2016 1 2 Foreword This Guide has been compiled in response to community and industry concerns that identified a need to collate general building standards
More informationChapter 2 Basis of design and materials
Chapter 2 Basis of design and materials 2.1 Structural action It is necessary to start a design by deciding on the type and layout of structure to be used. Tentative sizes must be allocated to each structural
More informationResidential Deck Safety, Construction, and Repair
Juneau Permit Center, 4 th Floor Marine View Center, (907)586-0770 This handout is designed to help you build your deck to comply with the 2006 International Residential Building code as modified by the
More informationMark Cramer Inspection Services, Inc.
Mark Cramer Inspection Services, Inc. 492 Twentieth Avenue, Indian Rocks Beach, FL 34635-2970 (727) 595-4211 Fax (727) 596-7583 Certified Member #12085 American Society of Home Inspectors Construction
More informationChapter 3 Pre-Installation, Foundations and Piers
Chapter 3 Pre-Installation, Foundations and Piers 3-1 Pre-Installation Establishes the minimum requirements for the siting, design, materials, access, and installation of manufactured dwellings, accessory
More information1.2.1 1.1.8 PRODUCTBLADEN GT ROCKPANEL STRUCTURE
1..1 1.1.8 PRODUCTBLADEN SHEETS GT page 1 to 6 Rockpanel Structure is a very durable panel with a lightly textured finish, specially developed for use in cladding, fascia, soffit applications. The basic
More informationWhat you need to know about concrete block basement construction.
Designing and planning your new residence is a vitally important process, which will have a great influence on the future enjoyment of your home. A successful process will ensure all areas of the home
More informationCHAPTER 6 CONSTRUCTION TYPES
CHAPTER 6 CONSTRUCTION TYPES SECTION 601 GENERAL 601.1 Scope. Provisions of this chapter shall govern the classification of construction type by materials and fire resistance of its elements and the use
More informationFLASHCLAD VERTICAL WEATHERBOARD CAVITY SYSTEM. Product. Scope. Appraisal No. 829 [2013] Appraisal No. 829 (2013) Amended 05 February 2016
WEATHERBOARD CAVITY SYSTEM Amended 05 February 2016 BRANZ Appraisals Technical Assessments of products for building and construction. Flashclad Limited PO Box 346 Kaiapoi 7633 North Canterbury Tel: 0800
More informationLPCB Red Book Listed Products and Passive Fire Protection Installer Schemes Answering the needs of the market
LPCB Red Book Listed Products and Passive Fire Protection Installer Schemes Answering the needs of the market Ian Stewart Passive installer scheme manager September 2011 Introduction to BRE Global Research,
More informationGuide to Assessment and Repair of Flood Damaged Timber and Timber Framed Houses
Technical Guide Guide to Assessment and Repair of Flood Damaged Timber and Timber Framed Houses ASSESSMENT OF DAMAGE Prior to any assessments or repairs being commenced, a licensed electrician must undertake
More informationElevating Your House. Introduction CHAPTER 5
CHAPTER 5 Elevating Your House Introduction One of the most common retrofitting methods is elevating a house to a required or desired Flood Protection Elevation (FPE). When a house is properly elevated,
More informationFIRE AND SMOKE PROTECTION FEATURES
CHAPTER 7 FIRE AND SMOKE PROTECTION FEATURES SECTION 70 GENERAL 70. Scope. The provisions of this chapter shall govern the materials, systems and assemblies used for structural fire resistance and fire-resistance-rated
More informationHow To Build A Luxury Apartment Complex In London
Post Tensioning Awards 2009 Project Summary Type of structure Location Architects Structural Engineer Residential with leisure suites including Swimming pool, Cinema, Virtual Golf, Wine Cellars, and Parking
More informationHDA -----------------------------------------------------------
----------------------------------------------------------- Lightstrips ---------------------------------------------------------------------- Ceiling system for heating and cooling LIGHTSTRIPS LIGHTSTRIPS
More informationRESIDENTIAL TIMBER DECKS
TECHNICAL DATA SHEET ISSUED BY TIMBER QUEELAND RESIDENTIAL TIMBER DECKS 4 RECOMMENDED PRACTICE // MARCH 2014 This data sheet contains TQ s recommendations for residential timber decks, verandahs, patios
More informationResidential Inspection Guidelines
Residential Inspection Guidelines 201 Pre-Pour Foundation Dimensions Building Location Certificate - if required in the building consent Construction and Advice Notes Check the building dimensions against
More informationINSTALLATION GUIDELINES for SOLAR PHOTOVOLTAIC SYSTEMS 1
City of Cotati Building Division 201 W. Sierra Ave. Cotati, CA 94931 707 665-3637 Fax 792-4604 INSTALLATION GUIDELINES for SOLAR PHOTOVOLTAIC SYSTEMS 1 Any PV system on a new structures should be included
More informationThe WANZ Guide to Window Installation
The WANZ Guide to Window Installation as described in E2/AS1 Amendment 5 2 of 60 Contents Overview 5 Objective 5 Scope 5 Opening Preparation 7 Step P1 Preliminary Check 8 Step P2 Cut the Underlay 9 Step
More informationSOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design
SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design Ideal installation for; Offices Branch Offices Schools Computer Aided Classes Government Offices Hotels
More informationINNOVATIONS. Economic Flat Roof Refurbishment with NOVOPROOF Sealing Systems. A Company of the SAARGUMMI Group
INNOVATIONS Economic Flat Roof Refurbishment with NOVOPROOF Sealing Systems A Company of the SAARGUMMI Group OUR SOLUTION TO REFURBISH ROOFS FOR LONG-TERM DURABILITY Quality and Experience from the Innovation
More informationCable Trays Technical Instructions & Specifications
Cable Trays Technical Instructions & Specifications Products Catalogue Objective and Structure The company s main objective is the supply of quality products, with respect to: practical design increased
More informationCI SfB. (4-) Nn2. Onduline. Mini Profile. Onduline Garden Roof Range. Onduline Building Products Ltd
CI SfB (4-) Nn2 Onduline Mini Profile Onduline Garden Roof Range Onduline Building Products Ltd Onduline Garden Roof Range Onduline Mini Profile The new Onduline Mini Profile sheets have been designed
More informationCPA Steel Stud Framing Page 1 of 11
CPA Steel Stud Framing Page 1 of 11 STEEL STUD FRAMING General Requirements City of Palo Alto (CPA) Building Inspection Division 285 Hamilton Ave. Inspection Request: 650 329-2496 Building Division IVR#
More information