Ball Valve Features and Benefi ts B2...VS/VSS, B3...L, B6...VS

Size: px
Start display at page:

Download "Ball Valve Features and Benefi ts B2...VS/VSS, B3...L, B6...VS"

Transcription

1 all Valve Features and enefi ts 2...VS/VSS, 3...L, 6...VS P /13 - Subject to change. elimo ircontrols (US), Inc. 2-way and 3-way confi guration ronze with stainless steel trim (2-way) Nickel plated brass body (3-way) educed and full port capacities Two piece construction Electronic actuation NPT and fl anged connections ide C v range ir gap for use with hot water and steam systems Live load low maintenance stem packing 2 year warranty US CND LTIN MEIC / CIEN 1

2 Flow Pattern, Operation and Installation all Valves FLO PTTEN Open CC Flow Direction Closed C to Open C to Open CC NOTE: 3 L are piped differently than 3 CCV Valves. VS SEIES LL VLVE PIPING DIGMS 2-way Valve Piping Diagram 3-way Diverting Valve Piping Diagram NOTE: To avoid torque increase during off season shut down, or other periods of inactivity longer than 1 month - the valve should be exercised (actuator or manually driven full open-closed cycle) at least once per month. This is necessary to avoid any application problems after an off season shut down. PIPING/MOUNTING OIENTTION ssembly can be mounted horizontally or vertically for water applications. For steam applications the valve can be mounted vertically but if mounted horizontally the valve must be 90 off center of the pipe. Do not install with actuator below pipe. (ater application only) (Steam or water application) P /13 - Subject to change. elimo ircontrols (US), Inc US CND LTIN MEIC / CIEN

3 Piping Sizing Geometry all Valves VLVE SIZE C v TYPE MODEL # ¾ Fp Cv 1 Fp Cv 1¼ Fp Cv 1½ Fp Cv LINE SIZE ½ 1 2 NPT 2050VS ½ 2 2 NPT 2050VS ½ 4 2 NPT 2050VS ½ 15 2 NPT 2050VS ¾ 30 2 NPT 9VS/VSS ¾ 51 2 NPT 0VS NPT 4VS/VSS NPT 5VS ¼ 48 2 NPT 2VS/VSS ½ 84 2 NPT 9VS/VSS ½ NPT 240VS NPT 249VS/VSS NPT 250VS ½ NPT 265VS/VSS NPT 280VS/VSS ½ NPT 315L ¾ NPT 320L NPT 325L ¼ 34 3 NPT 332L ½ 57 3 NPT 340L NPT 350L FLG 650VS ½ FLG 665VS FLG 680VS FLG 6100VS FLG 6150VS FLG 6200VS FLG 6250VS Fp Cv 2½ Fp Cv 3 Fp Cv 4 Fp Cv 5 Fp Cv 6 Fp Cv 8 Fp Cv 10 Fp Cv P /13 - Subject to change. elimo ircontrols (US), Inc US CND LTIN MEIC / CIEN 3

4 iring Instructions all Valves GENEL IING INSTUCTIONS NING The wiring technician must be trained and experienced with electronic circuits. Disconnect power supply before attempting any wiring connections or changes. Make all connections in accordance with wiring diagrams and follow all applicable local and national codes. Provide disconnect and overload protection as required. Use copper, twisted pair, conductors only. If using electrical conduit, the attachment to the actuator must be made with fl exible conduit. lways read the controller manufacturer s installation literature carefully before making any connections. Follow all instructions in this literature. If you have any questions, contact the controller manufacturer and/or elimo. Transformer(s) Typically actuators require a 24 VC class 2 transformer and draw a maximum of 10 V per actuator. The actuator enclosure cannot be opened in the fi eld, there are no parts or components to be replaced or repaired. EMC directive: 89/336/EEC Software class : Mode of operation type 1 Low voltage directive: 73//EEC Typical transformer sizing ctuator Series Voltage Max. V Per ctuator F LF N 24 4 L 24 3 CUTION It is good practice to power electronic or digital controllers from a separate power transformer than that used for actuators or other end devices. The power supply design in our actuators and other end devices use half wave rectifi cation. Some controllers use full wave rectifi cation. hen these two different types of power supplies are connected to the same power transformer and the DC commons are connected together, a short circuit is created across one of the diodes in the full wave power supply, damaging the controller. Only use a single power transformer to power the controller and actuator if you know the controller power supply uses half wave rectifi cation. Multiple actuators, one transformer Multiple actuators may be powered from one transformer provided the following rules are followed: 1. The TOTL current draw of the actuators (V rating) is less than or equal to the rating of the transformer. 2. Polarity on the secondary of the transformer is strictly followed. This means that all No. 1 wires from all actuators are connected to the common leg on the transformer and all No. 2 wires from all actuators are connected to the hotleg. Mixing wire No. 1 & 2 on one leg of the transformer will result in erratic operation or failure of the actuator and/or controls. Multiple actuators, multiple transformers Multiple actuators positioned by the same control signal may be powered from multiple transformers provided the following rules are followed: 1. The transformers are properly sized. 2. ll No. 1 wires from all actuators are tied together and tied to the negative leg of the control signal. See wiring diagram. ire type and wire installation tips For most installations, 18 or 16 Ga. cable works well with elimo actuators. Use code-approved wire nuts, terminal strips or solderless connectors where wires are joined. It is good practice to run control wires unspliced from the actuator to the controller. If splices are unavoidable, make sure the splice can be reached for possible maintenance. Tape and/or wire-tie the splice to reduce the possibility of the splice being inadvertently pulled apart. ire length for actuator installation Keep power wire runs below the lengths listed in the following tables. If more than one actuator is powered from the same wire run, divide the allowable wire length by the number of actuators to determine the maximum run to any single actuator. See section 1 for specifi c transformer sizing information for the actuator selected. Example: 3 actuators, 16 Ga wire 350 Ft 3 ctuators = 117 Ft. Maximum wire run P /13 - Subject to change. elimo ircontrols (US), Inc US CND LTIN MEIC / CIEN

5 Nomenclature all Valves 2 24 VS MX 24 -MFT-X1 Valve 2 = 2-way 3 = 3-way 6 = 2-way Flanged Valve Size = ½ to = 2 to 10 (Flanged) Industrial Cv Construction/ Material VS = ronze ody, Stainless Steel all and Stem VSS = Stainless Steel ody, all and Stem L = Nickel Plated rass ody, Chrome Plated rass all and Stem ctuator Type Non-Spring eturn LM NM M GM SY SY P Spring eturn LF NF F Electronic Fail-Safe GK... Power Supply 24 = 24 VC/DC 120 = 120 VC 0 = 0 VC Control -3-X1 = On/Off, Floating Point -MFT-X1 = Multi-Function Technology = Ω -S = uilt-in uxiliary Switch Ordering Example P /13 - Subject to change. elimo ircontrols (US), Inc. 1 Choose the valve actuator combination. 4VS+MX24-MFT-X1 2 Specify preference or confi guration. Non-Spring Models NO = Normally Open NC = Normally Closed Spring eturn Models NO/FO = Normally Open/Fail Open NO/FC = Normally Open/Fail Closed NC/FO = Normally Closed/Fail Open NC/FC = Normally Closed/Fail Closed efers to valve ports to. 3 Set-Up +NO For MFT orders only - select programming code +Tagging (if needed) P (01) P-100xx (xx) P-200xx (xx) P-300xx (Fxx) P-400xx (Jxx) X-XXXXX X-XXXXX Control voltage applications Pulse width modulation applications Floating point applications On/off applications Create custom MFT confi guration code Create custom MFT confi guration in the fi eld with MFT actuator PC software 4 Does order require tagging? Tagging: Valves may be tagged per customer specifi cation. ($10.00 per tag) Example: HU-1 FCU-2 Part number for tagging: Complete Ordering Example: 4VS+MX24-MFT-X1+NO US CND LTIN MEIC / CIEN 5

6 2...VS Series, 2-way, all Valve ronze ody, Stainless Steel all and Stem Live-load packing set Stainless steel ball & stem low-out proof stem design Technical Data Media chilled or hot water, glycol, 35# steam Flow characteristic modifi ed equal percentage ction 90 rotation valve open C, valve closed CC Sizes ½, ¾, 1, 1¼, 1½, 2, 2½, 3 Type of end fi tting SE NPT (female connections) Materials: 1 Stem packing reinforced PTFE 2 Stem bearing reinforced PTFE 3 all 316 stainless steel 4 Seat (x2) reinforced PTFE w/ Durafi ll 5 etainer 16 (¾ - 1 ) stainless steel 584 (1¼ - 3 ) stainless steel 6 Gland 16 brass 7 Stem 316 stainless steel 8 Jam nut stainless steel 9 ody seal PTFE (1-1/4 to 3 ) 10 ody 584-C84400 bronze pplication This valve is typically used in air handling units on heating or cooling coils, and fan coil unit heating or cooling coils. Some other common applications include Unit Ventilators, VV ox re-heat coils and bypass loops. This valve is suitable for use in a hydronic system with variable flow. This valve is designed with MFT functionality which facilitates the use of various control input. Up to 35 psi steam ½ PSIG OG, Cold Non-Shock. Federal Specification: -V-35C,Type II Composition: Z Style: 3 Valve Nominal Size Type Suitable ctuators C v Inches DN [mm] 2-way NPT Spring Non-Spring eturn eturn 1 ½ VS-01 2 ½ VS-02 4 ½ VS ½ VS ¾ 20 9VS 51 ¾ 20 0VS VS VS 48 1¼ 32 2VS 84 1½ 40 9VS 177 1½ VS VS VS 503 2½ VS VS LF Series NF F Series LM Series NM M Series GM Series SY Series Pressure rating 600 psig OG Media temp. range - F to +280 F (-30 C to +138 C) Close-off pressure F Maximum differential <600 psig pressure (ΔP) Flow Patterns 10 P /13 - Subject to change. elimo ircontrols (US), Inc US CND LTIN MEIC / CIEN

7 2...VSS Series, 2-way, all Valve Stainless Steel ody, all and Stem Live-load packing set Stainless steel ball & stem low-out proof stem design pplication These threaded valves are designed to provide modulating or two position control of hot or chilled water and saturated steam systems under 50 psi. Typical applications include reheat coils, vav terminal control, unit ventilators, and air handlers, especially in areas which have minimum profile requirements. Up to 50 psi steam ½ PSIG OG, Cold Non-Shock. Federal Specification: -V-35C,Type II, Composition: SS Style: 3 Technical Data Media chilled or hot water, glycol, 50# steam Flow characteristic modifi ed equal percentage ction 90 rotation valve open C, valve closed CC Sizes ½, ¾, 1, 1¼, 1½, 2, 2½ Type of end fi tting SE NPT (female connections) Materials: 1 Stem packing reinforced PTFE 2 Stem bearing reinforced PTFE 3 all 316 stainless steel 4 Seat (x2) reinforced PTFE w/ Durafi ll 5 etainer 16 (¾ - 1 ) stainless steel 584 (1¼ - 3 ) stainless steel 6 Gland Stem 316 stainless steel 8 Jam nut stainless steel 9 ody seal PTFE (1¼ to 3 ) 10 ody 351-CF8M 316 stainless steel Valve Nominal Size Type Suitable ctuators C v Inches DN Spring Non- Spring 2-way NPT [mm] eturn eturn 15 ½ VSS ¾ 20 9VSS VSS 48 1¼ 32 2VSS 84 1½ 40 9VSS VSS 503 2½ VSS LF Series F Series NM Series M Series GM Series SY Series P /13 - Subject to change. elimo ircontrols (US), Inc. Pressure rating 2000 psig OG (½ - 1 ) Media temp. range - F to +298 F (-30 C to +148 C) Close-off pressure F Maximum differential <600 psig pressure (ΔP) Flow Patterns US CND LTIN MEIC / CIEN 7

8 3...L Series, 3-way, all Valve Chrome Plated rass all and Nickel Plated Stem pplication This valve is typically used in air handling and fan coil units on heating or cooling coils, unit ventilators, VV box re-heat coils, and bypass loops. This valve is suitable for use as a diverting valve only. Technical Data Media Flow characteristic ction chilled or hot water, 60% glycol modifi ed linear 90 rotation to open C, to open CC Sizes ½, ¾, 1, 1¼, 1½, 2 Type of end fi tting NPT female ends Materials: ody nickel plated brass all chrome plated brass Stem nickel plated brass Stem seal o-ring EPDM Valve seat PTFE Leakage NSI VI Pressure rating 600 psig OG 600 psi DN (3...L) 400 psi DN (3...L) Media temp. range 0 F to 250 F [-18 C to +120 C] Close-off pressure 200 psi Maximum differential 50 psi pressure (ΔP) Valve Nominal Size Type Suitable ctuators C v Inches DN [mm] 3-way Spring Non-Spring Electronic NPT eturn eturn Fail-Safe 6.4 ½ L 12.8 ¾ L L 34 1¼ L 57 1½ L L LF Series F Series L Series N Series w Flow Patterns to Open C to Open CC P /13 - Subject to change. elimo ircontrols (US), Inc US CND LTIN MEIC / CIEN

9 6...VS Series, 2-way, all Valve Cast Iron ody, Stainless Steel all and Stem Same end to end dimension as conventional flanged iron gate valve Fast quarter turn open or closed operation Stainless steel ball and stem Positive shut-off Two-piece body construction Technical Data Media chilled or hot water, glycol, 50# steam Flow characteristic modifi ed equal percentage ction 90% rotation valve open C, valve closed CC Sizes 2, 2½, 3, 4, 6, 8, 10 Type of end fi ttings fl anged 125# NSI bolt pattern Materials: 1 ody cast iron - STM 126 Class 2 End cap cast iron - STM 126 Class 3 all 304 stainless steel - STM Seats PTFE 5 Stem 304 stainless steel - ISI Packing PTFE 7 Gland cast iron - STM 126 Class 8 Gasket PTFE 9 Nut steel - STM 6 pplication Ideal for water service where a non-corrosive, clean cosmetic appearance is required. Optional FD approval, suitable for potable water and food contact. Sizes: 2-10 (50-250mm) 200 psi CP (cold water pressure) (non-shock) pproved valves shall comply with the merican Standard for face-to-face dimensions (NSI 16.10) for Class 125 cast iron flanged gate valves. The dimensions and drilling of end flanges conform to the merican cast iron flange standard, Class 125 (NSI 16.1). Valve Nominal Size Type Suitable ctuators C v Inches DN [mm] 2-way NPT Non-Spring eturn VS 420 2½ VS VS VS VS VS VS SY Series Pressure rating 200 psig OG Media temp. range - F to +298 F (-30 C to +148 C) Close-off pressure F Maximum differential <200 psi pressure (ΔP) US CND LTIN MEIC / CIEN 9

10 This Page Intentionally Left lank P /13 - Subject to change. elimo ircontrols (US), Inc US CND LTIN MEIC / CIEN

11 all Valve Product ange Overview VS/VSS all Valve Product ange 2...VS/VSS, 3...L, 6...VS P /13 - Subject to change. elimo ircontrols (US), Inc. Valve Nominal Size Type Suitable ctuators C v Inches DN [mm] 2-way NPT 1 ½ VS-01 2 ½ VS-02 4 ½ VS ½ VS ¾ 20 9VS 51 ¾ 20 0VS VS VS 48 1¼ 32 2VS 84 1½ 40 9VS 177 1½ VS VS VS 190 2½ VS VS 15 ½ VSS ¾ 20 9VSS VSS 48 1¼ 32 2VSS 84 1½ 40 9VSS VSS 190 2½ VSS VSS 3-way NPT 6.4 ½ L 12.8 ¾ L L 34 1¼ L 57 1½ L L 2-ay Flanged VS 420 2½ VS VS VS VS VS VS Non-Spring eturn LM Series NM Series M Series GM Series NM Series M Series GM Series L Series N Series SY Series SY Series Spring eturn LF Series NF Series F Series LF NF F Series LF Series F Series Electronic Fail-Safe GK GK GK Mode of Operation The control valve is operated by an electronic actuator that responds to a standard voltage for on/off control, by a proportional VDC/4 20 m, or 3-point control system. The actuator will then move the ball of the valve to the position dictated by the contol signal thus changing the flow. Product Features Modified equal percentage of flow for 2, 3 and 6. Modified linear flow for 3. ctuator Specifications Control type Manual override Electrical connection Valve Specifications Service Flow characteristic on/off, fl oating point, proportional, 2-10 VDC multi-function technology (MFT) LM, NM, GM, M, SY, F, NF, GK 3 ft [1m] cable with ½ conduit fi tting Sizes ½ to 10 chilled or hot water, (60% glycol), steam modified equal percentage (2-way), modifi ed linear (3-way) End fi tting NPT (2...VS & 3.. L) fl anged (6...VS) Materials ody all Stem Seats 2-way 3-way Packing 2-way NPT 2-way fl anged Media temp range 2..VS, 6..VS 2..VSS 3...L ody pressure rating 3-way Maximum inlet pressure Steam ater Leakage bronze (2..VS), stainless steel (2..VSS), nickel plated brass (3...L), cast iron (6..VS) stainless steel, bronze (½ ) chrome plated brass (3...L) stainless steel, bronze (½ ) nickel plated brass (3...L) MPTFE LPTFE PTFE PTFE - F to +280 F [-30 C to +138 C] - F to +298 F [-30 C to +148 C] 0 F to 250 F [-18 C to +120 C] up to 2000 psig OG 600 psi DN (3...L) 400 psi DN (3...L) 35 psi 2..VS 50 psi 2..VSS, 6..VS 50 psi 3...L NSI class VI US CND LTIN MEIC / CIEN 11

12 LF ctuators, On/Off Dimensions with 2-ay Valve Models LF24 US LF24-S US LF120 US LF120-S US w/built-in ux. Switch w/built-in ux. Switch Technical Data Control on/off, fl oating point Power supply LF24(-S) US 24 VC ± 20% 50/60 Hz 24 VDC ± 10% LF120(-S) US 120 VC ± 10% 50/60 Hz Power consumption LF24(-S) US running 5 holding 2.5 LF120(-S) US running 5.5 holding 3.5 Transformer sizing 7 V, class 2 power source Electrical connection (-S models have 2 cables) ½ conduit connector 3 ft. [1m], 18 G appliance cable Electrical protection 120V actuators double insulated Overload protection electronic throughout rotation ngle of rotation 95 Spring return direction reversible with C/CC mounting Position indication visual indicator 0 to 90 unning time <40 to 75 sec. (on/off) spring <25 -4 F to +1 F [-20 C to +50 C] <60 - F [-30 C] mbient temperature - F to +1 F [-30 C to +50 C] Housing NEM 2 gency listings UL 873, CS C.2 No. 24 certifi ed, CE Quality standard ISO 9001 Noise level max. 62 d() LF...-S US uxiliary switch 1 x SPDT, VC, UL Listed, adjustable 0 to 95 (double insulated) ated impulse voltage 800V (4kV for 120V model), Control pollution degree 3, Type of action 1. (1.. for -S models) Valve Nominal Size Dimensions (Inches) Valve ody COP Inches DN [mm] C D F 2050VS ½ VS ½ VS ½ VS ½ VSS ½ Dimensions with 3-ay Valve Valve Nominal Dimensions (mm) Size Valve ody COP Inches DN [mm] C 315L 50 ½ [67] 1.73 [44] 1.42 [36] 320L 50 ¾ [78] 1.81 [46] 1.63 [42] 325L [87] 1.81 [46] 1.77 [45] P /13 - Subject to change. elimo ircontrols (US), Inc US CND LTIN MEIC / CIEN

13 LF ctuators, On/Off iring Diagrams 1 Provide overload protection and disconnect as required. 2 CUTION Equipment damage! ctuators may be connected in parallel. Power consumption must be observed. 3 ctuator may also be powered by 24 VDC. 4 For end position indication, interlock control, fan startup, etc., LF24-S US and LF120-S US incorporates a built-in auxiliary switch: 1 x SPDT, VC, UL listed, adjustable 0 to Common 2 + Hot 3 LF24 US 2 On/Off wiring for 24 VC/DC LF-08 Meets culus or UL and CS requirements without the need of an electrical ground connection. NING Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. On/Off wiring for 120 VC 048-UX uxiliary Switch P /13 - Subject to change. elimo ircontrols (US), Inc US CND LTIN MEIC / CIEN 13

14 LF24-MFT US ctuators, Multi-Function Technology Dimensions with 2-ay Valve Models LF24-MFT US LF24-MFT-S US w/built-in ux. Switch Technical Data Control MFT Control signal 2 to 10 VDC (4-20m with 500 Ω resistor) Power consumption running 2.5 holding 1 Transformer sizing 5 V (class 2 power source) Electrical connection (-S models have 2 cables) ½ conduit connector 3 ft. [1m], 18 G appliance cable Overload protection electronic throughout 0 to 95 rotation Input impedance 100 kω for 2 to 10 VDC (0.1 m) 500 Ω for 4 to 20m 750 Ω for PM 500 Ω for on/off and fl oating point Feedback 2 to 10 VDC, 0.5 m max ngle of rotation 95 Direction of rotation spring reversible with C/CC mounting motor reversible with built-in Position indication visual indicator unning time <40 to 75 sec. (on/off) 150 sec. independent of load (proportional) spring <25 -4 F to +1 F [-20 C to +50 C] <60 F [-30 C] mbient temperature - F to +1 F [-30 C to +50 C] Housing NEM 2 gency listings UL 873, CS C.2 No. 24 certifi ed, CE Noise level max. 62 d() Quality standard ISO 9001 LF24-MFT-S US uxiliary switch 1 x SPDT, VC, UL Listed, adjustable 0 to 95 (double insulated) Valve Nominal Size Dimensions (Inches) Valve ody COP Inches DN [mm] C D F 2050VS ½ VS ½ VS ½ VS ½ VSS ½ Dimensions with 3-ay Valve Valve Nominal Dimensions (mm) Size Valve ody COP Inches DN [mm] C 315L 50 ½ [67] 1.73 [44] 1.42 [36] 320L 50 ¾ [78] 1.81 [46] 1.63 [42] 325L [87] 1.81 [46] 1.77 [45] P /13 - Subject to change. elimo ircontrols (US), Inc US CND LTIN MEIC / CIEN

15 LF24-MFT US ctuators, Multi-Function Technology iring Diagrams 24 VC/DC Transformer CUTION Equipment damage! ctuators may be connected in parallel if not mechanically mounted to the same shaft. Power consumption and input impedance must be observed. Position ( ) Feedback VDC (+) a (1) Common (2) Hot (3) Y Input (5) U Output 3 ctuators may also be powered by 24 VDC. CC C MFT 4 IN4004 or IN4007 diode (IN4007 supplied, elimo part number 40155). 5 Triac and can also be contact closures. 6 7 Control signal may be pulsed from either the Hot (Source) or Common (Sink) 24 VC line. Position feedback cannot be used with Triac sink controller. The actuators internal common reference is not compatible. On/Off control (C only) 7 Position Feedback VDC ( ) (+) 6 (1) Common (2) + Hot (3) Y Input (5) U Output 041 The ZG Ω resistor converts the 4 to 20 m control signal to 2 to 10 VDC, up to 2 actuators may be connected in parallel. CC C MFT NING Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. PM, triac source and sink MFT P /13 - Subject to change. elimo ircontrols (US), Inc. Floating Point control Propotional 2 to 10 or 4 to 20 m control signal US CND LTIN MEIC / CIEN 15

16 NF ctuators, On/Off Dimensions with 2-ay Valve C F D Models NF24-X1 NFUP-X1 NFUP-S-X1 Technical Data Control Power consumption NF24-X1 NFUP-X1 Transformer sizing w/built-in ux. Switch on/off running 6 holding 2.5 running 6 holding 2.5 NF24-X1 NFUP(-S)-X1 8.5 V (class 2 power source) 6 24 VC (class 2 powe source) VC VC Electrical connection (-S model has 2 cables) ½ conduit connector 3 ft. [1m], 18 G appliance cables Electrical protection 120V actuators double insulated Overload protection electronic throughout 0 to 95 rotation ngle of rotation 95 Position indication visual indicator unning time control <75 seconds spring <20 seconds mbient temperature - F to +1 F [-30 C to +50 C] Housing NEM 2 / IP54 gency listings UL 873, CS C.2 No. 24 certified, CE Noise level max. 45 d() NFUP-S-X1 uxiliary switch 2 x SPDT, 3 ( V Valve Nominal Size Dimensions (Inches) Valve ody COP Inches DN [mm] C D F 9VS 400 ¾ VS 200 ¾ VSS 1000 ¾ P /13 - Subject to change. elimo ircontrols (US), Inc US CND LTIN MEIC / CIEN

17 NF ctuators, On/Off iring Diagrams 1 Provide overload protection and disconnect as required. 2 CUTION Equipment damage! ctuators may be connected in parallel. Power consumption must be observed. 3 ctuators may also be powered by 24 VDC. 4 For end position indication, interlock control, fan startup, etc., NF24-S US incorporates a built-in auxiliary switch: 1 x SPDT, VC, UL listed, adjustable 5 to 85. Meets culus or UL and CS requirements without the need of an electrical ground connection. 1 1 Common 2 + Hot 3 On/Off wiring for NF24-X1 NF24-X _NF(X) 066_NF(X)UP NING Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. NFUP-X1 NFUP-S-X1 On/Off wiring for NFUP-X1, NFUP-S-X1 ht lk 067_NF(X)UP-S P /13 - Subject to change. elimo ircontrols (US), Inc. uxiliary Switch NFUP-S-X US CND LTIN MEIC / CIEN 17

18 NF ctuators, Multi-Function Technology Dimensions with 2-ay Valve C F D Models NFX24-MFT-X1 NFX24-MFT-S-X1 Technical Data Control MFT Control signal 2 to 10 VDC, (4 to 20 m with 500 Ω resistor) Power supply 24 VC ± 20% 50/60 Hz 24 VDC ± 20% / -10% Power consumption running 6.5 holding 3 Transformer sizing 9 V, (class 2 power source) Electrical connection ½ conduit connector 3 ft. [1m], 18 G appliance cable Overload protection electronic throughout 0 to 95 rotation Input impedance 100 kω for 2 to 10 VDC (0.1 m) 500 Ω for 4 to 20 m 1500 Ω for on/off and fl oating point Feedback output 2 to 10 VDC, 0.5 m max ngle of rotation 95 Direction of rotation spring reversible with C/CC mounting motor reversible with built-in Position indication visual indicator, 0 to 95 unning time motor 150 seconds (default), variable (40 to 0 seconds) spring <20 -4 F to +1 F [-20 C to +50 C]; <60 - F [-30 F] mbient temperature - F to +1 F [-30 C to +50 C] Housing NEM 2 / IP54, Enclosure Type 2 gency listings culus acc. to UL / -2-14, CN/ CS E :02, CE acc. to 2004/108/EC & 2006/95/EC Noise level <40 d() 150 seconds, run time dependent <62 d() spring return NFX24-MFT-S-X1 uxiliary switch 2 x SPDT, VC, UL pproved one set at +10, one adjustable 10 to 90 Valve Nominal Size Dimensions (Inches) Valve ody COP Inches DN [mm] C D F 9VS 400 ¾ VS 200 ¾ VSS 1000 ¾ P /13 - Subject to change. elimo ircontrols (US), Inc US CND LTIN MEIC / CIEN

19 NF ctuators, Multi-Function Technology iring Diagrams 2 CUTION Equipment damage! ctuators may be connected in parallel if not mechanically mounted to the same shaft. Power consumption and input impedance must be observed. ( ) Control Signal (+) 4 to 20 m or 2 to 10 VDC Ω Ω 1/4 watt lk (1) Common ht (3) Y 1 Input, 2 to 10V Pnk (4) Y 2 Input Grn (5) U Output, 2 to 10V ctuators may also be powered by 24 VDC. CC C 4 IN4004 or IN4007 diode (IN4007 supplied, elimo part number 40155). VDC/4-20 m 5 Triac and can also be contact closures. 6 7 Control signal may be pulsed from either the Hot (Source) or Common (Sink) 24 VC line. Position feedback cannot be used with Triac sink controller. The actuators internal common reference is not compatible. ( ) 2 to 10 VDC Feedback Signal (+) lk (1) Common ed (2) Hot + ht (3) Y1 Input Pnk (4) Y2 Input Org (5) U Output 2 to 10V The ZG Ω resistor converts the 4 to 20 m control signal to 2 to 10 VDC, up to 2 actuators may be connected in parallel. Meets culus or UL and CS requirements without the need of an electrical ground connection. NING Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. Floating Point Direction of rotation switch CC CC C C 5 5 (C only) Position ( ) Feedback VDC (+) lk (1) Common ht (3) Y Input Pnk (4) Y 2 Input Org (5) U Output PM P /13 - Subject to change. elimo ircontrols (US), Inc. Two Position 24 VC/DC Transformer ( ) Position Feedback VDC (+) (C Only) ( ) Control Signal 2-10 VDC or 4 to 20 m (+) 7 Ω 500 Ω 1/4 watt Min* Mid* Max* Normal** C a Functions 0% 50% 100% Control mode acc. to Y lk (1) Common ed (2) Hot ht (3) Y Input Pnk (4) Y 2 Input Org (5) U Output 5 lk (1) Common ht (3) Y 1 Input, 2 to 10V Pnk (4) Y 2 Input Org (5) a b c * Default selectable 0-100%. See Configuration Data Sheet. ** Customizable. See Configuration Data Sheet. Override Control to Min, Mid, Max, Positions US CND LTIN MEIC / CIEN 19

20 NF ctuators, Multi-Function Technology Dimensions with 2-ay Valve C F D Models NFX24 Technical Data Control MFT Control signal Power supply 24 VC ± 20% 50/60 Hz 24 VDC ± 20% / -10% Power consumption running 6.5 holding 3 Transformer sizing 9 V (class 2 power source) Electrical connection ½ conduit connector 3 ft. [1m], 18 G appliance cable Overload protection electronic throughout 0 to 95 rotation Input impedance 100 kω for 2 to 10 VDC (0.1 m) 500 Ω for 4 to 20 m 1500 Ω for on/off and fl oating point Feedback output 2 to 10 VDC, 0.5 m max ngle of rotation 95 (adjustable with mechanical end stop, 35 to 95 ) Direction of rotation spring reversible with C/CC mounting motor reversible with built-in Position indication visual indicator, 0 to 95 unning time control 150 seconds (default), variable (40 to 0 seconds) spring <20 -4 F to +1 F [-20 C to +50 C]; <60 - F [-30 F] mbient temperature - F to +1 F [-30 C to +50 C] Housing NEM 2 / IP54, Enclosure Type 2 gency listings culus acc. to UL / -2-14, CN/ CS E :02, CE acc. to 2004/108/EC & 2006/95/EC Noise level <40 d() 150 seconds, run time dependent, <62 d() spring return Valve Nominal Size Dimensions (Inches) Valve ody COP Inches DN [mm] C D F 9VS 400 ¾ VS 200 ¾ VSS 1000 ¾ P /13 - Subject to change. elimo ircontrols (US), Inc US CND LTIN MEIC / CIEN

21 NF ctuators, Multi-Function Technology P /13 - Subject to change. elimo ircontrols (US), Inc Override INSTLLTION NOTES Provide overload protection and disconnect as required. ctuators and controller must have separate transformers. Consult controller instruction data for more detailed information. esistor value depends on the type of controller and the number of actuators. No resistor is used for one actuator. Honeywell resistor kits may also be used. To reverse control rotation, use the reversing switch. Switch Switch Damper Position Damper Open Damper Closed The direction of rotation switch is set so that the fail safe position and the position of the damper is closed with no signal at wire. Low Limit Control Series Ω Series 90 low limit control 135 Ω for 0 to 50% control 280 Ω for 0 to 100% control lk (1) Common ht (3) 24 ht (4) ht (5) lk (1) Common ht (3) 24 ht (4) ht (5) lk (1) Common ht (3) 24 ht (4) ht (5) High Limit Control Series 90 iring Multiple ctuators to a Series 90 lk (1) Common Series 90 high limit control Ω Shunting esistor 24 Series 90 No. of actuators esistance Ω Ω Ω Ω 6 28 Ω esistor Kit No. ZG-03 To other actuators lk (1) Common ht (3) 24 ht (4) ht (5) ht (3) 25 ht (4) ht (5) lk (1) Common ht (3) 25 ht (4) ht (5) iring Multiple ctuators to a Series 90 using a Minimum Position Potentiometer Series 90 Shunting esistor 24 H205 Changeover Occupied Contact To other actuators S963 Minimum Position Potentiometer lk (1) Common 25 ht (3) ht (4) ht (5) lk (1) Common ht (3) 25 ht (4) ht (5) Typical wiring diagrams for multiple actuators used with the 973, 7100 and T775 controllers 24 H205 Changeover Shunting esistor 973, 7100 No. of actuators esistance Ω Ω Ω esistor Kit No. ZG Shunting esistor Y 973, 7100 T775 Q209 Minimum Position Potentiometer To other actuators To other actuators lk (1) Common ht (3) 25 ht (4) ht (5) Occupied Contact Honeywell T675 Morning armup lk (1) Common ht (3) 25 ht (4) ht (5) Used with the 973 and 7100 controllers Honeywell T675 Morning armup Honeywell Q209 Minimum Position Potentiometer lk (1) Common ht (3) 25 ht (4) ht (5) lk (1) Common 020 ht (3) 25 ht (4) ht (5) US CND LTIN MEIC / CIEN

22 F ctuators, On/Off Dimensions with 2-ay Valve C F D Models F24-X1 FUP-X1 FUP-S-X1 Technical Data Control Power consumption FUP-X1 FUP-S-X1 Transformer sizing w/built-in ux. Switches on/off running 5 holding 2.5 running 7 holding 3.5 F24-X1 FUP(-S)-X1 7.5 V (class 2 power source) 7 24 VC (class 2 power source) VC VC Electrical connection (-S model has 2 cables) ½ conduit connector 3 ft. [1m], 18 G appliance cables Electrical protection 120V actuators double insulated Overload protection electronic throughout 0 to 95 rotation ngle of rotation 95 Position indication visual indicator Manual override hex crank unning time control 150 seconds independent of load spring <20 seconds mbient temperature - F to +1 F [-30 C to +50 C] Housing NEM 2 / IP54 gency listings UL 873, CS C.2 No. 24 certifi ed, CE Noise level max. 45 d() FUP-S-X1 uxiliary switches * Dual Mounted ctuators 2 x SPDT, VC, UL listed, one switch is fi xed at +5, one is adjustable 25 to 85 (double insulated) Valve Nominal Size Dimensions (Inches) Valve ody COP Inches DN [mm] C D F 4VS VS VS 200 1¼ *9VS 600 1½ *240VS 600 1½ *249VS VSS VSS ¼ *9VSS ½ *249VSS Dimensions with 3-ay Valve 4.04 [102.7] 3.93 [99.9] Valve Nominal Dimensions (mm) Size Valve ody COP Inches DN [mm] C 332L 50 1¼ [105] 2.00 [51] 2.19 [56] 340L 50 1½ [1] 2.44 [62] 2.61 [67] 350L [142] 2.67 [68] 3.11 [79] 9.77 [248.2] 2.50 [63.5] P /13 - Subject to change. elimo ircontrols (US), Inc US CND LTIN MEIC / CIEN

23 F ctuators, On/Off iring Diagrams 1 Provide overload protection and disconnect as required. 2 CUTION Equipment damage! ctuators may be connected in parallel. Power consumption must be observed. 3 ctuators may also be powered by 24 VDC. 4 For end position indication, interlock control, fan startup, etc., F24-S US incorporates two built-in auxiliary switches: 2 x SPDT, VC, UL listed, one switch is fi xed at +5, one is adjustable 25 to 85. p j y 1 Common 2 + Hot 3 F24-X1 2 On/Off iring for F24-X1 194_F24-X1 003_F24-X1 Meets culus or UL and CS requirements without the need of an electrical ground connection. NING Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. On/Off iring for FUP-X1, FUP-S-X1 FUP-X1 FUP-S-X1 195_FUP-S-X1 uxiliary Switches FUP-S-X1 P /13 - Subject to change. elimo ircontrols (US), Inc US CND LTIN MEIC / CIEN

24 F ctuators, Multi-Function Technology Dimensions with 2-ay Valve C F D Models FX24-MFT-X1 FX24-MFT-S-X1 FX24 w/built-in ux. Switches Technical Data Control MFT Control signal 2 to 10 VDC, (4 to 20 m with 500 Ω resistor) Ω (MFT95) Power supply 24 VC ± 20% 50/60 Hz 24 VDC ± 10% Power consumption running 7.5 holding 3 Transformer sizing 10 V (class 2 power source) Electrical connection (-S model has 2 cables) ½ conduit connector 3 ft. [1m], 18 G appliance cable Overload protection electronic throughout rotation Input impedance 100 kω for 2 to 10 VDC (0.1 m) 500 Ω for 4 to 20 m 750 Ω for PM 1500 Ω for on/off and fl oating point Feedback output 2 to 10 VDC, 0.5 m max ngle of rotation 95 Direction of rotation spring reversible with C/CC mounting motor reversible with built-in Position indication visual indicator Manual override hex crank unning time control 150 seconds independent of load spring <20 seconds mbient temperature - F to +1 F [-30 C to +50 C] Housing NEM 2 / IP54 gency listings UL 873, CS C.2 No. 24 certifi ed, CE Noise level max. 45 d() FX24-MFT-S-X1 uxiliary switches * Dual Mounted ctuators 2 x SPDT, VC, UL listed, one switch is fi xed at +5, one is adjustable 25 to 85 (double insulated) Valve Nominal Size Dimensions (Inches) Valve ody COP Inches DN [mm] C D F 4VS VS VS 200 1¼ *9VS 400 1½ *240VS 50 1½ *249VS VSS VSS ¼ *2VSS ¼ *9VSS ½ *249VSS Dimensions with 3-ay Valve 4.04 [102.7] 3.93 [99.9] Valve Nominal Dimensions (mm) Size Valve ody COP Inches DN [mm] C 332L 50 1¼ [105] 2.00 [51] 2.19 [56] 340L 50 1½ [1] 2.44 [62] 2.61 [67] 350L [142] 2.67 [68] 3.11 [79] 9.77 [248.2] 2.50 [63.5] P /13 - Subject to change. elimo ircontrols (US), Inc US CND LTIN MEIC / CIEN

25 F ctuators, Multi-Function Technology iring Diagrams 24 VC/DC Transformer CUTION Equipment damage! ctuators may be connected in parallel if not mechanically mounted to the same shaft. Power consumption and input impedance must be observed. Position ( ) Feedback VDC (+) a (1) Common (2) Hot (3) Y Input (5) U Output 3 ctuators may also be powered by 24 VDC. 4 IN4004 or IN4007 diode (IN4007 supplied, elimo part number 40155). On/Off control CC C MFT 5 Triac and can also be contact closures. 6 7 Control signal may be pulsed from either the Hot (Source) or Common (Sink) 24 VC line. Position feedback cannot be used with Triac sink controller. The actuators internal common reference is not compatible. (C only) 7 Position Feedback VDC ( ) (+) 6 (1) Common (2) + Hot (3) Y Input (5) U Output 041 The ZG Ω resistor converts the 4 to 20 m control signal to 2 to 10 VDC, up to 2 actuators may be connected in parallel. Meets culus or UL and CS requirements without the need of an electrical ground connection. NING Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. PM, triac source and sink CC C MFT 302_FX24-MFT...MFT P /13 - Subject to change. elimo ircontrols (US), Inc. Floating Point control Propotional 2 to 10 or 4 to 20 m control signal uxiliary Switches FX24-MFT-S-X US CND LTIN MEIC / CIEN 25

26 F ctuators, Multi-Function Technology Override INSTLLTION NOTES Provide overload protection and disconnect as required. ctuators and controller must have separate transformers. Consult controller instruction data for more detailed information. esistor value depends on the type of controller and the number of actuators. No resistor is used for one actuator. Honeywell resistor kits may also be used. To reverse control rotation, use the reversing switch. Switch Switch Damper Position Damper Open Damper Closed The direction of rotation switch is set so that the fail safe position and the position of the damper is closed with no signal at wire. Low Limit Control Series Ω Series 90 low limit control 135 Ω for 0 to 50% control 280 Ω for 0 to 100% control lk (1) Common ht (3) 24 ht (4) ht (5) lk (1) Common ht (3) 24 ht (4) ht (5) lk (1) Common ht (3) 24 ht (4) ht (5) High Limit Control Series 90 iring Multiple ctuators to a Series 90 lk (1) Common Series 90 high limit control Ω Shunting esistor 24 Series 90 No. of actuators esistance Ω Ω Ω Ω 6 28 Ω esistor Kit No. ZG-03 To other actuators lk (1) Common ht (3) 24 ht (4) ht (5) ht (3) 25 ht (4) ht (5) lk (1) Common ht (3) 25 ht (4) ht (5) iring Multiple ctuators to a Series 90 using a Minimum Position Potentiometer Series 90 Shunting esistor 24 H205 Changeover Occupied Contact To other actuators S963 Minimum Position Potentiometer lk (1) Common 25 ht (3) ht (4) ht (5) lk (1) Common ht (3) 25 ht (4) ht (5) Typical wiring diagrams for multiple actuators used with the 973, 7100 and T775 controllers 24 H205 Changeover Shunting esistor 973, 7100 No. of actuators esistance Ω Ω Ω esistor Kit No. ZG Shunting esistor Y 973, 7100 T775 Q209 Minimum Position Potentiometer To other actuators To other actuators lk (1) Common ht (3) 25 ht (4) ht (5) Occupied Contact Honeywell T675 Morning armup lk (1) Common ht (3) 25 ht (4) ht (5) Used with the 973 and 7100 controllers Honeywell T675 Morning armup Honeywell Q209 Minimum Position Potentiometer lk (1) Common ht (3) 25 ht (4) ht (5) lk (1) Common 020 ht (3) 25 ht (4) ht (5) P /13 - Subject to change. elimo ircontrols (US), Inc US CND LTIN MEIC / CIEN

27 LM()X24-3-X1, LX24-3 ctuators, On/Off, Floating Point Dimensions with 2-ay Valve PGE7 H2 H1 C F P /13 - Subject to change. elimo ircontrols (US), Inc. Models LM24-3-X1 LMX24-3-X1 LX24-3 Technical Data Control Power supply Power consumption Transformer sizing Electrical connection LM24-3-X1 on/off, fl oating point 24 VC ± 20% 50/60 Hz 24 VDC ± 10% running 1.5 holding V (class 2 power source) ½ conduit connector 3 ft., 18 G plenum rated cables Overload protection electronic throughout 0 to 95 rotation Input impedance 600 Ω ngle of rotation 95 Torque 45 in-lbs [5 Nm] Direction of rotation reversible with Position indication reflective visual indicator (snap-on) Manual override external push button unning time 95 seconds, constant independent of load Humidity 5 to 95% H non-condensing (EN ) mbient temperature - F to +1 F [-30 C to +50 C] Storage temperature -40 F to +176 F [-40 C to +80 C] Housing NEM type 2/IP54 Housing material UL94-5V gency listings culus acc. to UL /-2-14, CN/CS C.2 No. 24 certifi ed, CE acc. to 73//EEC Noise level <35 db() Servicing maintenance free Quality standard ISO 9001 D Valve Nominal Size Dimensions (Inches) Valve ody COP Inches DN [mm] C D F H1 H2 2050VS ½ VS ½ VS ½ VS ½ Dimensions with 3-ay Valve Valve Nominal Dimensions (mm) Size Valve ody COP Inches DN [mm] C 315L 50 ½ [67] 1.73 [44] 1.42 [36] 320L 50 ¾ [78] 1.81 [46] 1.63 [42] 325L [87] 1.81 [46] 1.77 [45] US CND LTIN MEIC / CIEN 27

28 LM()X24-3-X1, LX24-3 ctuators, On/Off, Floating Point iring Diagrams Provide overload protection and disconnect as required. 3 ctuators may also be powered by 24 VDC. Meets culus or UL and CS requirements without the need of an electrical ground connection. NING Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualified licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. On/Off control Floating Point or On/Off control Piping The valve should be mounted in a weather-protected area in a location that is within the ambient limits of the actuator. llow suffi cient room for valve with actuator and for service. llow 6 for cover removal and 12 for complete actuator removal. The assembly can be mounted with the actuator vertical or horizontal in relation to the pipe. The actuators should never be mounted underneath the valve, as condensation can build up and result in a failure of the actuators. Do not reverse fl ow direction. P /13 - Subject to change. elimo ircontrols (US), Inc US CND LTIN MEIC / CIEN

29 LMX24-MFT-X1, LX24-MFT ctuators, Multi-Function Technology Dimensions with 2-ay Valve PGE7 H2 H1 C F P /13 - Subject to change. elimo ircontrols (US), Inc. Models LMX24-MFT-X1 LX24-MFT Technical Data Power supply 24 VC ± 20% 50/60 Hz 24 VDC ± 10% Power consumption 2 Transformer sizing 3.5 V (class 2 power source) Electrical connection 3 ft. [1m], 10 ft. [3m], 16 ft. [5m] 18 G plenum rated cable ½ conduit connector Overload protection electronic throughout 0 to 95 rotation Input impedance 100k Ω for 2 to 10 VDC (0.1 m) 500 Ω for 4 to 20 m 750 Ω for PM 1500 Ω for on/off and fl oating point Feedback 2 to 10 VDC, 0.5 m max VDC variable ngle of rotation 95 Torque 45 in-lbs [5 Nm] Direction of rotation reversible with Position indication reflective visual indicator (snap-on) Manual override external push button unning time 150 seconds (default) variable (35 to 150 seconds) Humidity 5 to 95% H non-condensing (EN ) mbient temperature - F to +1 F [-30 C to +50 C] Storage temperature -40 F to +176 F [-40 C to +80 C] Housing NEM type 2/IP54 Housing material UL94-5V gency listings culus acc. to UL /-2-14, CN/CS E , CS C.2 No , CE acc. to 89/336/EEC Noise level <35 db() Servicing maintenance free Quality standard ISO 9001 D Valve Nominal Dimensions (Inches) Size Valve ody COP Inches DN [mm] C D F H1 H2 2050VS ½ VS ½ VS ½ VS ½ Dimensions with 3-ay Valve Valve Nominal Dimensions (mm) Size Valve ody COP Inches DN [mm] C 315L 50 ½ [67] 1.73 [44] 1.42 [36] 320L 50 ¾ [78] 1.81 [46] 1.63 [42] 325L [87] 1.81 [46] 1.77 [45] US CND LTIN MEIC / CIEN 29

30 LMX24-MFT-X1, LX24-MFT ctuators, Multi-Function Technology iring Diagrams 1 Provide overload protection and disconnect as required. 3 ctuators may also be powered by 24 VDC. 4 5 Position feedback cannot be used with Triac sink controller. The actuator internal common reference is not compatible. Control signal may be pulsed from either the Hot (source) or the Common (sink) 24 VC line. 1 3 Position 24 VC/DC Transformer ( ) Feedback VDC (+) a 2 lk (1) Common ed (2) Hot ht (3) Y Input Org (5) U Output ZG-01 may be used. 7 8 Contact closures & also can be triacs. & should both be closed for triac source and open for triac sink. For triac sink the common connection from the actuator must be connected to the hot connection of the controller. On/Off control 1 2 lk (1) Common ed (2) Hot to 10 VDC Feedback Signal 7 4 ht (3) Y 1 Input 8 Pnk (4) Y 2 Input Org (5) U Output 2 to 10V MFT Floating Point 1 3 Control Signal 4 to 20 m or 2 to 10 VDC ( ) (+) Ω 500Ω 1/4 watt 6 2 lk (1) Common ht (3) Y 1 Input, 2 to 10V Org (5) U Output, 2 to 10V 399 MFT VDC/4-20 m PM 1 (C only) 2 Position Feedback VDC ( ) (+) 5 lk (1) Common ht (3) Y Input Org (5) U Output T 399 P /13 - Subject to change. elimo ircontrols (US), Inc US CND LTIN MEIC / CIEN

Pressure Independent Characterized Control Valves (PICCV)

Pressure Independent Characterized Control Valves (PICCV) Pressure Independent haracterized ontrol s (PIV) Easy direct coupling of actuator with a single screw. Perpendicular mounting ISO flange and square drive head eliminate lateral forces on the stem. Vent

More information

Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC 100... 240 V Control: Open/close or 3-point Auxiliary switch

Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC 100... 240 V Control: Open/close or 3-point Auxiliary switch echnical data sheet Rotary actuator LR-S Rotary actuator for and -way (control) ball valves orque 5 Nm Nominal voltage C... 4 V Control: Open/close or -point uxiliary switch echnical data Electrical data

More information

How To Control A Motorized Motorized Power Control (Motorized Motor Control) (Mft)

How To Control A Motorized Motorized Power Control (Motorized Motor Control) (Mft) Technical Documentation Multi-Function Technology (MFT) for Damper and Control Valve Applications Effective May 2010 Multi-Function Technology Your swiss army knife for HVAC. We set standards. www.belimo.com

More information

Installation Instructions

Installation Instructions 0.1.2....6.7..9 1 0.1.2....6.7..9 1 Installation Instructions Quick-Mount Visual Instructions for Mechanical Installation Quick-Mount Visual Instructions 1. Rotate the damper to its fail-safe position.

More information

WE-350 Series ¼ Turn Electric Actuator

WE-350 Series ¼ Turn Electric Actuator WE-350 Series ¼ Turn Electric Actuator Operation and Installation Manual Pg 1 (Rev. 020113) Table of Contents 1.0 General 1.1 Pre-Installation Inspection 1.2 Storage 1.3 Features & General Information

More information

4 Posiflow Proportional Solenoid Valves

4 Posiflow Proportional Solenoid Valves 4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,

More information

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed. FANs 268.1, 1628.3 Installation Bulletin M100Q Issue Date 1099 M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications I nstallation Parts Included M110QGA-1 and

More information

Heating, air-conditioning, cooling

Heating, air-conditioning, cooling Series description Design High efficiency, single stage, low pressure, inline centrifugal pump Supplied with EC motor and electronic duty adaptation Available in glanded construction, mechanical shaft

More information

VG2000 Series Cast Iron Flanged Globe Valves

VG2000 Series Cast Iron Flanged Globe Valves VG2000 Series ast Iron Flanged Globe Valves Installation Instructions Part No. 14-1161-106, Rev. Issued November 15, 2013 Supersedes June 15, 2007 pplications VG2000 Series ast Iron Flanged Globe Valves

More information

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES PRODUCT DATA Design VC Series zone valves consist of: 2-way or 3-way valve housing available with various connection ends Spindle and cartridge

More information

TAC Erie VT/VS PopTop Series Two Position Spring Return Valves

TAC Erie VT/VS PopTop Series Two Position Spring Return Valves TC 1354 Clifford venue P. O. ox 2940 Loves Park, IL 61132-2940 www.tac.com TC Erie VT/VS PopTop Series Two Position Spring Return Valves General & High Close-Off PopTop Zone Valves General Instructions

More information

Assisted lift operated 2/2-way solenoid valves Type EV250B

Assisted lift operated 2/2-way solenoid valves Type EV250B MAKING MODERN LIVING POSSIBLE Data sheet Assisted lift operated 2/2-way solenoid valves Type EV250B EV250B with assisted lift can operate from zero and up to 10 bar differential pressure. This 2/2-way

More information

QLM and QLD Series Three-port Control Valves

QLM and QLD Series Three-port Control Valves Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

2012 Valve & Valve Actuator Catalog. For new construction or retrofits, simplify projects with our complete selection. www.usa.siemens.

2012 Valve & Valve Actuator Catalog. For new construction or retrofits, simplify projects with our complete selection. www.usa.siemens. 2012 Valve & Valve Actuator Catalog For new construction or retrofits, simplify projects with our complete selection. www.usa.siemens.com/hvac Our dynamic duos provide comprehensive control. Fast installation

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

Butterfly Valves PN 6/10/16 for flanged connection

Butterfly Valves PN 6/10/16 for flanged connection 4 136 ACVATIX Butterfly Valves PN 6/10/16 for flanged connection tight-closing VKF46.. VKF46..TS Grey cast iron housing EN-GJL-250 (to DN 300) nodular cast iron housing EN-GJS-400-15 (from DN 350) DN 40

More information

XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY

XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY PRODUCT SPECIFICATION SHEET switched off. This results in energy savings during mild weather. Normal control will resume when T3 fails to

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays

More information

2- and 3-port valves with flanged connections, PN 10

2- and 3-port valves with flanged connections, PN 10 4 402 VVF32.. VXF32.. ACVATIX 2 and 3port valves with flanged connections, PN 10 From the largestroke valve line VVF32.. VXF32.. Performance valves for medium temperatures from 10 150 C Valve body of grey

More information

HVAC Valves and Actuators Catalogue

HVAC Valves and Actuators Catalogue HVAC Valves and Actuators Catalogue Issue: September 2008 Make the most of your energy TAC the Single Source for all your Valve and Actuator Needs This catalogue presents the comprehensive HVAC Valve and

More information

225-230T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

225-230T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators Actuators Technical data sheet 225-230T-05-S2 Rotary drive without spring return Description Actuator for adjusting air dampers of 90 angle of rotation to be used in HVAC installations. Torque Motor 5

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical

More information

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM TAC I/NETTM TM TAC s TM has an extensive range ofpre-engineered VAV control sequences, which combined with a fully integrated actuator and airflow transducer, makes it a low Total Installed Cost solution

More information

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES 2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES DIRECT ACTING Brochure N-289 SPECIFICATIONS Port Size: 1/8 and1/4 Solenoid Valve for air, oil, water and other fluids Flow Direction:

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4 to 1 NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power .55 W Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies /" to " NPT / 3/ / 5/ 5/3 Features Molded one-piece solenoid with highly efficient solenoid cartridge and.55 W low wattage coil Standard

More information

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51 34 Series - Slim electromechanical PCB relays 6 34 SERIES Features 34.51 Ultra-slim 1 Pole - 6 relay Printed circuit mount - direct or via PCB socket 35 mm rail mount - via screw, screwless or push-in

More information

T7560A,B,C Digital Wall Module

T7560A,B,C Digital Wall Module T7560A,B,C Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. Digital

More information

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application 33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection

More information

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection

More information

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit) 000W Single Output Power Supply AK-000 series Features: Universal AC input / Full range Programmable output Voltage (0% ~ 05%) Programmable output Current (% ~ 05%) + / 0.5A auxiliary output U profile,

More information

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve Mist Spray Unit Series MU/ Intermittent spray to cutting and press gear chains, etc. Standard Specifications MU MU Inlet air Oil tank set range. MPa. to. MPa Oil tank capacity (cm ) Total capacity: Effective

More information

4/2-Way Pneumatic Solenoid Valve

4/2-Way Pneumatic Solenoid Valve 4/2-Way Pneumatic Solenoid Valve Robust servo assisted piston valve Service friendly manual override Single or block assembly Explosion-proof versions Type 5413 cam be combined with Type 2508 Cable plug

More information

Electric Rotary Actuator - On/Off or programmable control actuator

Electric Rotary Actuator - On/Off or programmable control actuator Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type

More information

Type overview. Technical data

Type overview. Technical data Technical data sheet R3..xx-S.. Characterised control valve, 3-way, Internal thread For closed cold and warm water systems For modulating water-side control of air handling units and heating systems ir

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and

More information

Pneumatic Control and Shut-off Butterfly Valve Pfeiffer Type BR 14b/31a and Type BR 14c/31a

Pneumatic Control and Shut-off Butterfly Valve Pfeiffer Type BR 14b/31a and Type BR 14c/31a Pneumatic Control and Shut-off Butterfly Valve Pfeiffer Type BR 14b/31a and Type BR 14c/31a Application Tight-closing, double eccentric butterfly valve for process engineering and plants with industrial

More information

How To Use A Flowmeter

How To Use A Flowmeter INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power Features: Universal AC input / Full range Programmable output Voltage (0% ~ 05%) Programmable output Current (% ~ 05%) + / 0.5A auxiliary output Forced current sharing at parallel operation Power OK signal

More information

Valve and Valve Actuator Selection Guide

Valve and Valve Actuator Selection Guide www.sbt.siemens.com/hvp/components Building Technologies Building Technologies Siemens Building Technologies, Inc. 1000 Deerfield Parkway Buffalo Grove, IL 60089-4513 USA Tel 847 215 1000 Siemens Building

More information

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency echnical data sheet NV24A--RE Communicative globe valve actuator for 2-way and 3-way globe valves Actuating force 1000 N Nominal voltage AC/DC 24 V Control Modulating DC (0)2...10 V Variable Nominal stroke

More information

Relays High Capacity 50 Amp Mini Relays Standard Mini Relays Micro Relays Power Relays Connector Modules

Relays High Capacity 50 Amp Mini Relays Standard Mini Relays Micro Relays Power Relays Connector Modules CHIEF EN TERPRISES INC. M a s t e r I n t e r n a t i o n a l D i s t r i b u t o r Relays High Capacity 50 Amp Mini Relays Standard Mini Relays Micro Relays Power Relays Connector Modules M AS TER IN

More information

DN [mm] [m 3 /h] Characterizing disk Dimensions / Weights see «Dimensions and weights», page 3 Motorizing

DN [mm] [m 3 /h] Characterizing disk Dimensions / Weights see «Dimensions and weights», page 3 Motorizing Technical data sheet R5.. Characterized control valves, 3-way, with external thread for open and closed cold and warm water systems for modulating control on the water side of air-handling and heating

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2... Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast

More information

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils

More information

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply) transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control

More information

MFP14, MFP14S and MFP14SS Automatic Pumps

MFP14, MFP14S and MFP14SS Automatic Pumps Page 1 of 6 TI-P136-02 ST Issue 12 Cert. No. LRQ 0963008 ISO 9001, S and SS utomatic Pumps Description The Spirax Sarco automatic pump is a displacement receiver operated by steam or compressed air. It

More information

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval. www.frese.

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval. www.frese. Page 1 of 6 Application Proportional 0-10V or 3-position modulating or On/ Off control of Frese OPTIMA Compact valves in heating, ventilating and air conditioning systems. The actuator can be mounted on

More information

Overview of types. Technical data

Overview of types. Technical data Technical data sheet R3..xx-S.. Characterised control valves, 3-way, with internal thread For closed cold and warm water systems For modulating water-side control of HU and heating systems ir bubble-tight

More information

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01 ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions

More information

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M1115-2 (Angle) Schematic. Standard Components Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Throttles to maintain minimum upstream pressure PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE

More information

PRESSURE REDUCING CONTROL VALVE

PRESSURE REDUCING CONTROL VALVE Schematics Throttles to reduce high upstream pressure to constant lower downstream pressure Low Flow By-Pass controls at low flows 4 PRESSURE REDUCING CONTROL VALVE with LOW FLOW BY-PASS FEATURE Main Line

More information

650W Single Output Power Supply

650W Single Output Power Supply AK-650 series Features : Universal AC input with active PFC Programmable output Voltage ( 0% ~ 05% ) Programmable output Current ( % ~ 05% ) High efficiency up to 9% + / 0.5A auxiliary output Intelligent

More information

! WARNING. Before using product, read and understand instructions.

! WARNING. Before using product, read and understand instructions. McDonnell & Miller Installation & Maintenance Instructions MM-600G) Series FS8-W General Purpose Liquid Flow Switch OPERATION This control is an independently mounted water flow sensing device that makes

More information

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6. 38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC

More information

Duct Humidity Transmitter

Duct Humidity Transmitter SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers

More information

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER (PWM Input, 1.2A or 2A Output, Metal Box or PCB) PCB Board - P/N: PWMC-PCB-2A, PWMC-PCB-1.2A Packaged Driver (metal box with 1.5 m (5 ft.) cable)

More information

Spira-trol TM Two-port Control Valves EN Standard KE, KF and KL DN15 to DN300 and ASME Standard KEA, KFA and KLA ½" to 12"

Spira-trol TM Two-port Control Valves EN Standard KE, KF and KL DN15 to DN300 and ASME Standard KEA, KFA and KLA ½ to 12 Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR MAIN FEATURES The pneumatic S GATE knife gate valve is intended for the automatic shut off of pipes of the heavy fluids like slurries and powders. The main fields of application are the water treatment,

More information

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing) CHRONOMITE INSTANT-FLOW MICRO WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No.

More information

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) TECHNICAL DATASHEET #TD1102AX CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version) Part Number: Connector Amplifier CAPV-H-4-20MA-x complete with cable CAPV-4C-yM Where: x = current output

More information

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250 MAKING MODERN LIVING POSSIBLE Data sheet OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250 The compact OEM pressure transmitter programme is designed for use in severe hydraulic

More information

TorqPlus TM Electric Valve Actuators and Controls

TorqPlus TM Electric Valve Actuators and Controls TorqPlus TM Electric Valve Actuators and Controls Torque 150 IN/LB 600 IN/LB The Engineered Solution Bettis TorqPlus quality line of electric actuators are designed for quarter turn applications ball,

More information

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008 Installation Manual Rental Services Air Handling Units July 2008 CHS-SVN01A-EN Copyright 2008 Trane All rights reserved This document and the information in it are the property of Trane and may not be

More information

GENERAL PRODUCT OVERVIEW

GENERAL PRODUCT OVERVIEW CONTROLS Pneumatic Controls comprehensive range of factory supplied, installed and calibrated controls are available for pressure independent control applications with all terminal types. Pressure dependent

More information

MasterINTERFACE 39 Series - Relay interface modules

MasterINTERFACE 39 Series - Relay interface modules MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

AURORA. 1030 AND 1040 Series SUCTION DIFFUSERS, COMBINATION AND TRIPLE DUTY VALVES WWW.AURORAPUMP.COM

AURORA. 1030 AND 1040 Series SUCTION DIFFUSERS, COMBINATION AND TRIPLE DUTY VALVES WWW.AURORAPUMP.COM UROR 1030 ND 1040 Series SUCTION DIFFUSERS, COMINTION ND TRIPLE DUTY VLVES WWW.URORPUMP.COM UROR 1030 ND 1040 Series Suction Diffusers, Combination and Triple Duty Valves Designed for Direct Mounting on

More information

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp. EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium

More information

Automatic control equipment for HVAC systems

Automatic control equipment for HVAC systems Automatic control equipment for HVAC systems Products for domestic and industrial installations In buildings, the main aim of the installations is to guarantee and maintain a comfortable ambient. Watts

More information

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv) Order code Series and function 1) Plug socket see page 5.042. MN-06-310-HN-442 Standard coil 1) 441 = 12 V DC, 4.2 W 442 = 24 V DC,

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,

More information

Introduction. Angle/Flared/Sequence/Changeover Service Valves. Valves D-193. www.usa.siemens.com/hvac

Introduction. Angle/Flared/Sequence/Changeover Service Valves. Valves D-193. www.usa.siemens.com/hvac Introduction Angle/Flared/Sequence/Changeover Service D-193 In this section, you will find flared, angled, sequence and changeover valves for use in service applications. D-194 Need additional assistance?

More information

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) CHRONOMITE INSTANT-FLOW WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No. Wattage

More information

Safety automation solutions

Safety automation solutions Operating principle, characteristics Preventa safety s types XPS AV,, For and switch monitoring Operating principle Safety s XPS AV, and are used for monitoring circuits conforming to standards EN/ISO

More information

Oil and Coolant Circulating Heating System. Model - OCSM

Oil and Coolant Circulating Heating System. Model - OCSM Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically

More information

Centro-Matic Automatic Lubrication Systems System Controls

Centro-Matic Automatic Lubrication Systems System Controls Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the

More information

Compressor Service & Maintenance Manual

Compressor Service & Maintenance Manual Compressor Service & Maintenance Manual C Series COMPRESSOR (D)C1103 (D)C1203 (D)C2106 (D)C2206 (D)C3210 Copyright 2006 DCI. All Rights Reserved. 92311, Rev. C, 08/13 1 C1000 Series Service & Maintenance

More information

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to: OPERATING LIMITS Flows up to: m /h* Heads up to: m C Max operating pressure: bars Temperature range: - à + C Max ambient temperature: + C ND of orifices: à * m /h: parallel operation SIRIUX SINGLE AND

More information

Know-how makes the difference. Electrical Actuators

Know-how makes the difference. Electrical Actuators Know-how makes the difference Electrical Actuators With Dansk Ventil Center as your business partner, you are always guaranteed a wide and well sorted product range and a unique technical know-how Product

More information

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS Technical Information sheet 0001/07/Rev01 ENG FUNCTION Series S001 and S002 circulation units are applied to the primary circuit of solar

More information

Redundancy Module QUINT-DIODE/40

Redundancy Module QUINT-DIODE/40 Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping

More information

DMX-K-DRV. Integrated Step Motor Driver + (Basic Controller) Manual

DMX-K-DRV. Integrated Step Motor Driver + (Basic Controller) Manual DMX-K-DRV Integrated Step Motor Driver + (Basic Controller) Manual DMX-K-DRV Manual page 1 rev 1.33 COPYRIGHT 2007 ARCUS, ALL RIGHTS RESERVED First edition, June 2007 ARCUS TECHNOLOGY copyrights this document.

More information

Float and Thermostatic Traps Series H, C and X

Float and Thermostatic Traps Series H, C and X Hoffman Specialty Installation & Maintenance Instructions HS-(E) and Thermostatic Traps Series H, C and X Series C & NPT Series C NPT Series X NPT Series C NPT Series H Ratings Maximum Max. Operating NPT

More information

ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves

ball valves Flomite 71 Series 2-way Integral Panel Mount Ball Valves 2-way Integral Panel Mount Ball Valves Used for quick on-off service with a visual indication of flow, HOKE s 2-way ball valves offer orifice sizes up to 0.25 (6.4mm). Flomite valves feature a floating

More information

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 techsupport@securitron.com in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate

More information

Air damper actuators

Air damper actuators 4 634 OpenAir TM Air damper actuators GDB...1 GLB...1 Rotary version, / AC 230 V Electronic motor driven actuators for three-position and modulating control Nominal torque 5 Nm (GDB), 10 Nm (GLB) Mechanically

More information

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223 3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223 HERION S HIGH PERFORMANCE POPPET VALVES For those applications requiring high Cv, fast response times, large

More information

N20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL

N20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL N2xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL SPECIFICATIONS Supply voltage N224A / N3424A N223A / N3423A PRODUCT DATA 24 Vac 15%, 5/6 Hz 23 Vac 15%,

More information

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics 3/2-, 5/2-5/3-way Solenoid Valves for process pneumatics Type 6518 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 6518/6519 can be combined with... Stard-,

More information

M9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators

M9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators M9102-AGA-2S, -3S and M9104-xxA-2S, -3S Series Electric Non-Spring Return Actuators Product Bulletin Code No. LIT-1201742 Issued February 12, 2015 The M9102 and M9104 Series Actuators are directmount,

More information

Cable Plug acc. to DIN EN 175301-803, Form A

Cable Plug acc. to DIN EN 175301-803, Form A Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with

More information

Specifying a Variable Frequency Drive s

Specifying a Variable Frequency Drive s Specifying a Variable Frequency Drive s Put on by Bruce Reeves and Jeremy Gonzales Dykman Electrical Covering the Western US For all of your VFD and Soft Start and Motor Needs How To Specify a Variable

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

TIG INVERTER INSTRUCTION MANUAL

TIG INVERTER INSTRUCTION MANUAL TIG INVERTER INSTRUCTION MANUAL Contents Warning General Description Block Diagram Main Parameters Circuit Diagram Installation and Operation Caution Maintenance Spare Parts List Troubleshooting 3 4 4

More information

HENRY TECHNOLOGIES - OIL LEVEL REGULATORS (CONVENTIONAL)

HENRY TECHNOLOGIES - OIL LEVEL REGULATORS (CONVENTIONAL) HENRY TECHNOLOGIES - OIL LEVEL REGULATORS (CONVENTIONAL) The oil level regulator controls the oil level in the compressor crankcase with a float operated valve. Oil level regulators are designed to attach

More information

Data sheet ECC 12 and 22

Data sheet ECC 12 and 22 Application ECC is an electronic room temperature controller for water-based systems. ECC can control - fan-coil units - inductions units - air conditioning systems - small ventilating systems - 2-pipe

More information

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC) Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC) VPS 504 S06 (120 VAC) is: CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter R-15 (Canada) UL

More information