1 ABACUS ALS Rev DEC Immucor Gamma Product Catalogue IG /01 CAT
2
3 Table of Contents 1 2 Table of Contents Manual Reagents 3 Reagent Red Blood Cells 5 ABO Blood Grouping Anti-sera 6 Rh Blood Grouping Anti-sera 7 Rare Anti-sera 10 Anti-Human Globulin Sera 11 Potentiators/Enzymes 12 Quality Control 13 Proficiency Testing 14 Specialty Products 15 Accessories 16 Blood Bank Automation Systems 17 NEO 18 Echo 19 Manual Capture Work Station 20 Capture Products 21 Red Blood Cells 23 Platelets 24 Plates and Consumables 25 Reagent Red Blood Cells and ABO/Rh Blood Grouping Anti-sera 26 Rh and Kell Blood Grouping Anti-sera and Rare Anti-sera 27 Quality Control 28 Parts and Consumables 1 Immucor, Inc. Product Catalogue IG /01 CAT
4 Manual Reagents Immucor, Inc. Product Catalogue IG /01 CAT 2
5 Reagent Red Blood Cells Antibody Screening Product Code Product Name Size Description IG2377 Panoscreen I, II and III, including C W 3 x 10 ml Reagent red blood cells from three group O donors for antibody screening, including antigen C W, for the detection of unexpected antibodies. IG2380 Panoscreen I and II 2 x 10 ml IG2223 Hemantigen 1 x 10 ml Reverse Grouping Product Code Product Name Size Description Reagent red blood cells from two group O donors for antibody screening for the detection of unexpected antibodies. Pooled reagent red blood cells from two group O donors for antibody screening for the detection of unexpected antibodies. IG2338 Referencells A1, A2, B and O 4 x 10 ml Confirmation of ABO Serum Grouping. IG2345 Referencells A1 and B 2 x 10 ml Confirmation of ABO Serum Grouping. IG2342 Referencells A2 1 x 10 ml Confirmation of ABO Serum Grouping. Coombs Control Cells Product Code Product Name Size Description IG2224 Checkcell 1 x 10 ml IG2226 Checkcell (Weak) 1 x 10 ml IG7930 Complement Control Cells 1 x 3 ml IgG coated red blood cells for the confirmation of Antiglobulin reagents. IgG coated red blood cells for the confirmation of Antiglobulin reagents. Group 0 red blood cells sensitised with C3b (C3c+C3d) for the confirmation and QC of Antiglobulin reagents. 3 Immucor, Inc. Product Catalogue IG /01 CAT
6 Reagent Red Blood Cells (Continued) Panels Product Code Product Name Size Description IG3032 Panocell x 3 ml* Reagent red blood cell panel for the identification of unexpected antibodies (10 selected cells + 1 Tech Cell + 1 buffered preservative diluent). IG2332 Panocell x 3 ml Reagent red blood cell panel for the identification of unexpected antibodies (16 selected cells). IG5020 Panocell x 3 ml Reagent red blood cell panel for the identification of unexpected antibodies (20 selected cells). Ficin-Treated Panels Product Code Product Name Size Description IG2385 Panocell 10, Ficin Treated 24 x 3 ml* Ficin-treated reagent red blood cell panel for the identification of unexpected antibodies (treated & untreated pair + 1 Tech Cell + 1 buffered preservative diluent + Ficin Solution + 1 Ficin Control). *The Tech Cell is a rare phenotype bonus cell which may have a 2mL or 3mL fill volume. Immucor, Inc. Product Catalogue IG /01 CAT 4
7 ABO Blood Grouping Anti-sera Monoclonal Reagents Product Code Product Name Size Clone DB NOVACLONE Anti-A IgM 5 x 10 ml A98 DB NOVACLONE Anti-A IgM 10 x 10 ml A98 IG Anti-A Gamma-clone 5 x 10 ml Birma - 1 IG Anti-A Gamma-clone 10 x 10 ml Birma - 1 DB NOVACLONE Anti-B IgM 5 x 10 ml B84 + B97 DB NOVACLONE Anti-B IgM 10 x 10 ml B84 + B97 IG Anti-B Gamma-clone 5 x 10 ml GAMA 110 IG Anti-B Gamma-clone 10 x 10 ml GAMA 110 DB NOVACLONE Anti-A,B IgM 5 x 10 ml A98 + B84 + B97 + AB125 DB NOVACLONE Anti-A,B IgM 10 x 10 ml A98 + B84 + B97 + AB125 IG Anti-A,B Gamma-clone 5 x 10 ml Birma-1, ES4, ES15 IG Anti-A,B Gamma-clone 10 x 10 ml Birma-1, ES4, ES15 Lectin Product Code Product Name Size Description IG12280 DB IG7151 DB Anti-A1 Lectin Anti-H Lectin 1 x 5 ml 1 x 5 ml GX5602 Anti-A hel 1 x 2 ml Phythemagglutinine of Dolichus biflorus for the identification of group A(1) erythrocytes Phythemagglutinine of Ulex europaeus for the detection of H-substance Protectine of Helix pomatia for differentiation of group A(2), A(2)B and A(3), A(3)B erythrocytes 5 Immucor, Inc. Product Catalogue IG /01 CAT
8 Rh Blood Grouping Anti-sera Monoclonal Reagents (continued) Product Code Product Name Size Clone DB NOVACLONE Anti-D IgM + IgG 5 x 10 ml D175 (IgM) + D415 (IgG) DB NOVACLONE Anti-D IgM + IgG 10 x 10 ml D175 (IgM) + D415 (IgG) IG Anti-D IgM-IgG Blend Gamma-clone 5 x 10 ml GAMA401, F8D8 IG66420 Anti-D IgM-IgG Blend Gamma-clone 10 x 10 ml GAMA401, F8D8 IG66421 Anti-C, Gamma-clone 1 x 5 ml MS24 IG66425 Anti-c 1 x 5 ml MS33 IG66422 Anti-E, Gamma-clone 1 x 5 ml GAMA402 IG66424 Anti-e, Gamma-clone 1 x 5 ml MS16, MS21, MS63 GX7603 immuclone Anti-C W 1 x 5 ml MS110 IG42045 Gamma-clone Control 5 x 10 ml IG Gamma-clone Control 10 x 10 ml GX67205 immuclone Rh-Hr Control 5 x 10 ml GX6721 immuclone Rh-Hr Control 10 x 10 ml Immucor, Inc. Product Catalogue IG /01 CAT 6
9 Rare Anti-sera Kell System Product Code Product Name Size Clone IG4210 Anti-K 1 x 5 ml MS56 IG7537 Anti-k (Cellano) 1 x 5 ml (Polyclonal, human) IG7540 Anti-Kpa 1 x 2 ml (Polyclonal, human) IG7550 Anti-Kpb 1 x 2 ml (Polyclonal, human) GX99140 Anti-Jsb 1 x 2 ml (Polyclonal, human) Duffy System Product Code Product Name Size Clone IG7591 Anti-Fya 1 x 5 ml (Polyclonal, human) IG7594 Anti-Fyb 1 x 5 ml (Polyclonal, human) Kidd System Product Code Product Name Size Clone GX8306 immuclone Anti-Jka, IgM 1 x 5 ml MS15 GX8315 immuclone Anti-Jkb, IgM 1 x 5 ml MS8 IG7601 Anti-Jka 1 x 5 ml (Polyclonal, human) IG7604 Anti-Jkb 1 x 5 ml (Polyclonal, human) Lewis System Product Code Product Name Size Clone IG4861 Anti-Lea, Gamma-clone 1 x 5 ml GAMA701 IG4864 Anti-Leb, Gamma-clone 1 x 5 ml GAMA704 7 Immucor, Inc. Product Catalogue IG /01 CAT
10 Rare Anti-sera (continued) Lutheran System Product Code Product Name Size Clone GX8108 Anti-Lua 1 x 2 ml (Polyclonal, human) GX8109 Anti-Lub 1 x 2 ml (Polyclonal, human) MNS System Product Code Product Name Size Clone IG4802 Anti-M, Gamma-clone 1 x 5 ml M2A1 IG4807 Anti-N, Gamma-clone 1 x 5 ml 12E.A1 IG7454 Anti-S 1 x 5 ml (Polyclonal, human) GX9905 Anti-S 1 x 5 ml MS94 GX9909 Anti-s 1 x 2 ml P3BER Lectin Product Code Product Name Size IG4146 Anti-N Lectin (Vicia graminea) 1 x 5 ml P System Product Code Product Name Size Clone IG4501 Anti-P1, Gamma-clone 1 x 5 ml OSK17 Immucor, Inc. Product Catalogue IG /01 CAT 8
11 Rare Anti-sera (continued) Colton System Product Code Product Name Size Clone GX99100 Anti-Coa 1 x 2 ml (Polyclonal, human) GX8307 Anti-Cob 1 x 2 ml (Polyclonal, human) Diego System Product Code Product Name Size Clone IG7620 Anti-Dia 1 x 2 ml (Polyclonal, human) GX99120 Anti-Wra 1 x 2 ml (Polyclonal, human) 9 Immucor, Inc. Product Catalogue IG /01 CAT
12 Anti-Human Globulin sera Polyspecific, Monoclonal and Polyclonal Product Code Product Name Colour Size Clone DB NOVACLONE Anti-IgG, -C3d Green 5 x 10 ml 5H4 + 8D2-8, 86 5A2, 139 4B4 DB NOVACLONE Anti-IgG, -C3d Green 10 x 10 ml 5H4 + 8D2-8, 86 5A2, 139 4B4 IG Anti-IgG, -C3d, Gamma-clone Green 5 x 10 ml 16H8, GAMA003,GAMA004 IG Anti-IgG, -C3d, Gamma-clone Green 10 x 10 ml 16H8, GAMA003,GAMA004 GX4810 Anti-Human Globulin Serum (Anti-IgG, C3d) Green 1 x 10 ml (Polyclonal, Rabbit) Monospecific, Monoclonal and Polyclonal Product Code Product Name Colour Size Clone DB NOVACLONE Anti-IgG Clear 5 x 10 ml 5H4 + 8D2-8 DB NOVACLONE Anti-IgG Clear 10 x 10 ml 5H4 + 8D2-8 IG Anti-IgG,Gamma-clone Clear 5 x 10 ml 16H8 IG Anti-IgG,Gamma-clone Clear 10 x 10 ml 16H8 GX3002 Anti-IgA 1 x 2 ml (Polyclonal, Sheep) GX3003 Anti-IgM 1 x 2 ml (Polyclonal, Sheep) Monoclonal Product Code Product Name Size Clone IG4068 Anti-C3b, -C3d, Gamma-clone 1 x 5 ml GAMA003,GAMA004 DB NOVACLONE Anti-C3d 1 x 3 ml 139 4B4 Immucor, Inc. Product Catalogue IG /01 CAT 10
13 Potentiators / Enzymes Product Code Product Name Size Use IG % Bovine Albumin 10 x 10 ml Protein Additive IG2008 ImmuAdd 10 x 10 ml Low Ionic Strength Additive IG Gamma LO-ION 10 x 10 ml Low Ionic Strength Additive IG Gamma N-HANCE 10 x 10 ml Low Ionic Strength Additive IG70505 Gamma PeG 5 x 10 ml Polyethylene Glycol Additive IG Gamma PeG 10 x 10 ml Polyethylene Glycol Additive IG7056 Gamma Zyme-F 1 x 10 ml Ficin Solution for Two-Stage Test Procedures IG7058 Gamma Zyme-B 1 x 10 ml Bromelin Solution for One-Stage Test Procedures IG57292 Freeze Dried Papain 10 x 2 ml Proteolytic Enzyme 11 Immucor, Inc. Product Catalogue IG /01 CAT
14 Quality Control Product Code Product Name Size Use Description IG2400 corqc 2 x 11.5 ml Quality Control of Routine Reagents The corqc test system is designed for use in daily quality control of routine blood bank reagents. The kit consists of one vial of reagent cells and one vial of reagent antiserum. IG2417 corqc EXTEND 3 x 5 ml Quality Control for Rh and Kell blood grouping reagents The corqc EXTEND test system is designed for use in daily quality control of Rh and Kell blood grouping reagents. The kit consists of one vial of RhC positive, one vial of RhE positive and one vial of RhD negative/ Kell Positive reagents. IG2995 Weak D Cells 1 x 5 ml Quality Control of Anti-D Reagents Weak D Cells are supplied as a 3-4% suspension of selected human weak D red blood cells. They are to be used for quality control of Anti-D reagents in the Indirect Antiglobulin Test for weak D. IG7930 Complement Control Cells 1 x 3 ml Quality Control of Anti-Human Globulin Complement Control Cells are supplied as a 3-4% suspension of C3b (C3c/C3d) coated red blood cells. They are to be used for confirming reactivity of the anti-c3 component of Anti-Human Globulin for reagent quality control and for confirmation of negative antiglobulin tests. GX99204 Anti-D Standards kit 3 x 5 ml For Sensitivity Control of Anti- Human Globulin Test The kit consists of 3 anti-d controls, 0.1iu/ml, 0.05iu/ ml and 0.025iu/ml. GX99430 Coombs Control Serum 1 x 10 ml For use as a control to confirm the sensitivity of Coombs techniques and is for use in tube tests Coombs Control Reagent is a weak IgG (D) antibody (usually anti-d of 0.3 IU/ml or less). Immucor, Inc. Product Catalogue IG /01 CAT 12
15 Proficiency Testing Product Code Product Name Size Use Description IG2999 Tech-Chek Kit Confirmation of Competency Tech-Chek is designed to provide laboratory supervisors with the ability to educate technical staff and monitor their competency on a regular basis. This kit ships every four weeks on a subscription basis and contains two vials of either serum or cells. Includes enough sample to permit at least two technologists to undertake testing. IG56169 Self-check II Kit Confirmation of Competency and Proficiency Self-check II consists of "unknown" serum and cell samples for testing. This kit ships every four weeks on a subscription basis and includes all materials necessary for individual proficiency testing in your laboratory. Includes enough sample to permit at least two technologists to undertake testing. IG7999 RiSE Kit Confirmation of Proficiency RiSE is a self-evaluation proficiency test system which combines basic and advanced immunohaematologic problems. This kit is shipped quarterly on a subscription basis and contains enough "unknown" serum or cell sample to enable at least two technologists to undertake testing. 13 Immucor, Inc. Product Catalogue IG /01 CAT
16 Specialty Products Product Code Product Name Size Use IG7861 Gamma ELU-KIT II Kit For rapid acid elution of antibodies from intact red blood cells. IG7865 Gamma EGA Kit (EDTA Glycine Acid) Kit For antigen typing of DAT positive red blood cells by dissociation of IgG, inactivates Kell antigens. IG57319 W.A.R.M. (Warm Autoantibody Removal Medium) 10 x 5 ml For removal of warm-reactive red blood cell autoantibodies. IG57316 RESt (Rabbit Erythrocyte Stroma) 8 tests Eliminates Unwanted Cold Autoagglutinins. IG57320 H.P.C. (Human Platelet Concentrate) 10 x 1 ml Removes Unwanted HLA-related Antibodies. IG7700 P1 Blood Group Substance 1 x 2 ml Neutralization of Anti-P1 Antibodies. IG7702 Lewis Blood Group Substance 1 x 2 ml Neutralization of Anti-Lewis Antibodies. IG7890 Gamma -Quin 1 x 10 ml Removal of Red Cell-bound Immunoglobulin. IG7870 Gamma Lectin System 3 x 5 ml Investigation of Red Cell Polyagglutination. Immucor, Inc. Product Catalogue IG /01 CAT 14
17 Accessories Product No Product Name Size IG2900 Gamma Purple Marking Pens 12 per pack IG Tier Reagent Rack 10 vial capacity IG Tier Reagent Rack 20 vial capacity 15 Immucor, Inc. Product Catalogue IG /01 CAT
18 Blood Bank Automation Systems NEO Echo Manual Capture Work Station Immucor, Inc. Product Catalogue IG /01 CAT 16
19 Blood Bank Automation Systems NEO TM The NEO is a fully automated, high throughput, walk-away analyser with a flexible design and a broad test menu. Test Menu: ABO/Rh Full Group (2 clones available) ABO/Rh Group Confirmation (2 clones available) Donor Confirmation Rh and Kell Phenotyping Extended Phenotyping Antibody Screening (2-cell, 3-cell, 4-cell & Pooled cell) 14 cell Antibody Identification Panel (Primary Panel, D-positive Panel, D-negative Panel) Weak D IgG DAT IgG Crossmatch Platelet Antibody Screen Platelet Antibody Crossmatch It features continuous random access and STAT capability; plus, its Dynamic Scheduler prioritizes workflow to maximize efficiency. Using Immucor Gamma's patented Capture Solid Phase technology, the NEO has superior sensitivity and specificity. Product Code GX64600 Description NEO 17 Immucor, Inc. Product Catalogue IG /01 CAT
20 Blood Bank Automation Systems Echo The Echo is a fully automated, walk-away benchtop analyzer. With its fast turnaround time and broad test menu, it is perfect for the small to medium sized laboratories or as a back-up system for the NEO. Test Menu: ABO/Rh Full Group (2 clones available) ABO/Rh Group Confirmation (2 clones available) Donor Confirmation Rh and Kell Phenotyping Antibody Screening (3-cell) 14 cell Antibody Identification Panel (Primary Panel, D-positive Panel, D-negative Panel) Weak D IgG DAT IgG Crossmatch It features continuous random access, STAT capability and reflex testing. With over 1100 systems placed worldwide in the last 5 years, the Echo is revolutionizing how Blood Banking is done. Product Code GX87000 Description Echo Immucor, Inc. Product Catalogue IG /01 CAT 18
21 Blood Bank Automation Systems Manual Capture Work Station Due to it's high level of sensitivity and specificity, Immucor Gamma has been using Capture solid phase technology as an alternative to tube testing and column agglutination for over 20 years. Capture solid phase can be performed both manually on the Capture Work Station or automated on the NEO and/ or Echo. Capture can be used with erythrocytes (Capture-R) and platelets (Capture- P). For example, Capture-R is performed by adding plasma or serum from a patient or donor and Capture LISS to a microtitre well that has been coated with red cell antigens. During the incubation phase, if antibodies are present in the plasma or serum, they will adhere to the well. Next, a brief wash step is performed followed by the addition of Capture- R indicator cells and then a brief centrifugation step. Capture is read by looking for a button of packed red cells at the bottom of the well (negative) to a full coating of red cells across the well (positive). Product Code IG15159 IG15158 GX5175 GX30205 IG5133 Description Immuspin Centrifuge Immuspin Rotor CSW 100 Washing System P2 Incubator Light Box Viewer 19 Immucor, Inc. Product Catalogue IG /01 CAT
22 Capture Products Immucor, Inc. Product Catalogue IG /01 CAT 20
23 Capture Products - Red Blood Cells Screening Plates Product Code Product Name Size Description IG66804 IG66814 Capture-R Ready-Screen (3), including C W, Kpa Capture-R Ready-Screen (3), including C W, Kpa For use on: NEO, Echo, Work Station 1 plate/ 24 tests 5 plates/120 tests Eight well microtitre strips coated with red cell membranes from three group O donors plus an additional well with a built-in positive control. Each strip is sufficent to perform two antibody screens. IG66203 IG66213 Capture-R Ready-Screen (Pooled Cells), including C W Capture-R Ready-Screen (Pooled Cells), including C W 1 plate/ 96 tests 5 plates/ 480 tests Eight well microtitre strips each coated with red cell membranes from a pooled suspension of two group O donors. Each strip is sufficient to perform eight antibody screens. For use on: NEO, Work Station IG66202 IG66212 Capture-R Ready-Screen (I and II), including C W Capture-R Ready-Screen (I and II), including C W 1 plate/ 48 tests 5 plates/240 tests Eight well microtitre strips coated with red cell membranes from two group O donors. Each strip is sufficient to perform four antibody screens. For use on: NEO, Work Station IG66802 IG66812 Capture-R Ready-Screen (4) Capture-R Ready-Screen (4) 1 plate/24 tests 5 plates/120 tests Eight well microtitre strips coated with red cell membranes from four group O donors. Each strip is sufficient to perform two antibody screens. For use on: NEO, Work Station 21 Immucor, Inc. Product Catalogue IG /01 CAT
24 Capture Products - Red Blood Cells (continued) Identification Plates Product Code Product Name Size Description IG66204 IG66214 Capture-R Ready-ID Capture-R Ready-ID For use on: NEO, Echo, Work Station 1 plate/6 tests 5 plates/30 tests Sixteen microtitre well strips coated with red cell membranes from fourteen group O donors plus positive and negative control wells. Donors are selected to possess most of the frequently inherited antigens. Each strip is sufficient to perform one antibody ID. IG6454 IG6455 Capture-R Ready-ID Extend I Capture-R Ready-ID Extend I For use on: NEO, Echo, Work Station 1 plate/6 tests 5 plates/30 tests Sixteen microtitre well strips coated with D-positive red cell membranes from fourteen group O donors plus positive and negative control wells. Each strip is sufficient to perform one antibody ID. IG6456 IG6457 Capture-R Ready-ID Extend II Capture-R Ready-ID Extend II For use on: NEO, Echo, Work Station 1 plate/6 tests 5 plates/30 tests Sixteen microtitre well strips coated with D-negative red cell membranes from fourteen group O donors plus positive and negative control wells. Each strip is sufficient to perform one antibody ID. Select Plates Product Code Product Name Size Description IG6446 Consumables Capture-R Select For use on: NEO, Echo, Work Station 5 plates/480 tests These microtitre wells are coated for the immobilization of human erythrocytes to be used in solid phase assays for the detection of IgG red cell antibodies (e.g., selected red cell panels, autologous controls, direct antiglobulin test, crossmatching, or typing with IgG anti-sera including weak D testing and extended phenotyping). Product Code Product Name Size IG6428 Capture-R Ready Indicator Red Cells For use on: NEO, Echo, Work Station 10 x 10 ml IG66236 Capture-R Control Set (Weak Positive/Negative) For use on: NEO, Echo, Work Station 2 x 11.5 ml Immucor, Inc. Product Catalogue IG /01 CAT 22
25 Capture Products - Platelets Platelet Antibody Assays Product Code Product Name Size Description IG66247 IG66240 IG66248 Capture-P Ready-Screen Capture-P Indicator Cells Capture-P Control Set Weak Positive & Negative Controls 1 Plate/6 tests 1 x 11.5 ml 2 x 3 ml Sixteen microtitre well strips coated with platelet membranes from thirteen group O donors. Each strip is sufficient to perform six patient tests and will detect platelet-specific and HLA antibodies. For use on: NEO, Work Station IG66246 IG66251 IG66240 Capture-P Capture-P Capture-P Indicator Cells 1 Plate/96 tests 5 Plates/480 tests 1 x 11.5 ml Each mictotire well is coated with anti-platelet antibodies to bind platelets in plasma. The assay will detect platelet-specific and HLA antibodies. IG66248 Capture-P Control Set 2 x 3 ml Weak Positive & Negative Controls For use on: NEO, Work Station IG5035 Capture-P Platelet Wash and Storage Solution 1 liter bag 23 Immucor, Inc. Product Catalogue IG /01 CAT
26 Capture Products - Plates and Consumables Microtitre Plates Product Code Product Name Size Description IG89000 CMT Plates 40 plates Coated microtiter plates for haemagglutination assays on the Echo. GX66050 NEO Plates 100 plates Blank bar coded microplates for haemagglutination assays on the NEO. Consumables Part Number Product Name Size For use on: IG6420 Capture LISS 10 x 11.5 ml NEO, Echo, Work Station GX66056 System Liquid Concentrate 10 x 500 ml NEO, Echo, Work Station GX66052 Echo Specimen Diluent 10 x 11.5 ml Echo GX66055 NEO Specimen Diluent 10 x 500 ml NEO IG6226 Stir balls 2 x 50 pieces NEO, Echo IG6074 Stir ball dispenser 1 piece NEO, Echo GX66078 PeraSafe 10 sachets NEO, Echo Immucor, Inc. Product Catalogue IG /01 CAT 24
27 Capture Products - Reagent Red Blood Cells and ABO/Rh Blood Grouping Anti-sera Reverse Grouping Product Code Product Name Size Description IG2338 Referencells A1, A2, B and O 4 x 10 ml Confirmation of ABO Serum Grouping IG2345 Referencells A1 and B For use on: NEO, Echo 2 x 10 ml Confirmation of ABO Serum Grouping Monoclonal Reagents Product Code Product Name Size Use Clone DB NOVACLONE Anti-A IgM, Galileo 10 x 10 ml ABO Blood Grouping A98 GX66080 immuclone Anti-A IgM, Galileo 10 x 10 ml ABO Blood Grouping Birma - 1 DB NOVACLONE Anti-B IgM, Galileo 10 x 10 ml ABO Blood Grouping B84 + B97 GX66081 immuclone Anti-B IgM, Galileo 10 x 10 ml ABO Blood Grouping GAMA 110 DB NOVACLONE Anti-A,B IgM, Galileo 10 x 10 ml ABO Blood Grouping A98 + B84 + B97 + AB125 GX66082 immuclone Anti-A,B IgM, Galileo 10 x 10 ml ABO Blood Grouping Birma-1, ES4, ES15 GX66085 immuclone Anti-D rapid IgM, Galileo 10 x 10 ml Rh Blood Typing RUM-1 GX66037 NOVACLONE Anti-D IgM + IgG, Galileo 10 x 10 ml Rh Blood Typing D175 (IgM) + D415 (IgG) GX66010 immuclone Anti-CDE IgM + IgG, Galileo 1 x 10 ml Rh Blood Typing Anti-C: MS24 (IgM) + Anti-D: MS201 (IgM) + Anti-D: MS26 (IgG) + Anti-E: MS80 (IgM) 25 Immucor, Inc. Product Catalogue IG /01 CAT
28 Capture Products - Rh and Kell Blood Grouping Anti-sera and Rare Anti-sera Rh Typing Product Code Product Name Size Clone GX66011 immuclone (1) Anti-C IgM, Galileo 10 ml MS24 GX66012 immuclone (2) Anti-C IgM, Galileo 10 ml MS273 GX66013 immuclone (1) Anti-c IgM, Galileo 10 ml MS33 GX66014 immuclone (2) Anti-c IgM, Galileo 10 ml MS35 GX66015 immuclone (1) Anti-E IgM, Galileo 10 ml MS258 + MS80 GX66016 immuclone (2) Anti-E IgM, Galileo 10 ml MS12 + MS260 GX66017 immuclone (1) Anti-e IgM, Galileo 10 ml MS16 + MS21 + M63 GX66018 immuclone (2) Anti-e IgM, Galileo 10 ml MS62 + MS69 GX66019 immuclone Anti-C w IgM, Galileo 10 ml MS110 GX66083 immuclone Rh-Hr control, Galileo control serum for monoclonal Rh-sera 10 x 10 ml Kell Typing Product Code Product Name Size Clone GX66020 immuclone (1) Anti-K IgM, Galileo 10 ml MS56 GX66088 immuclone (2) Anti-K IgM, Galileo 10 ml K1.21.HM.EF Extended Typing Product Code Product Name Size Clone GX66021 immuclone Anti-M, Galileo 5 ml M-11H2 GX66300 Anti-Fya micro 5 ml (Polyclonal, human) GX66301 Anti-Fyb micro 5 ml (Polyclonal, human) GX66302 Anti-Jka micro 5 ml (Polyclonal, human) GX66303 Anti-Jkb micro 5 ml (Polyclonal, human) GX66304 Anti-S micro 5 ml (Polyclonal, human) GX66305 Anti-s micro 5 ml (Polyclonal, human) GX66307 Anti-C w micro 5 ml (Polyclonal, human) GX66306 Anti-k (Cellano) micro 5 ml (Polyclonal, human) GX66299 Negative Control micro control serum for micro sera for use on Capture R Select 5 ml Immucor, Inc. Product Catalogue IG /01 CAT 26
29 Capture Products - Quality Controls Product Code Product Name Size Platform Description IG66090 WBcorQC 2 sets of 4 x 4.5 ml Echo Whole blood QC sets for reagent and process control IG66296 corqc EXTEND Standard 1 x 10 ml NEO, Work Station Test reagent for quality control IG66297 corqc EXTEND Complete 1 x 10 ml, 4 x 5 ml NEO, Work Station Test system for quality control IG66122 DAT positive Control cells 1 x 10 ml NEO, Echo, Work Station For use with Capture R Select IG66125 DAT positive Control cells 4 x 10 ml NEO, Echo, Work Station For use with Capture R Select 27 Immucor, Inc. Product Catalogue IG /01 CAT
30 Capture Products - Parts and Consumables Product Code Description Platform Size GX66806 Balance Strips NEO, Echo 1 plate/12 strips GX65012 Sample Rack (13 mm tubes) NEO 1 each GX65013 Paediatric Rack (13 mm tubes) NEO 1 each GX65014 Donor Rack (13 mm tubes) NEO 1 each GX65018 Sample Rack (16 mm tubes) NEO 1 each GX65016 Reagent Rack (12 vial capacity) NEO 1 each GX65246 Reagent Rack (9 vial capacity) NEO 1 each GX65030 Plate Carrier NEO 1 each GX87280 Sample Rack Echo 1 each GX87289 Paediatric Rack Echo 1 each GX87288 Donor Rack Echo 1 each GX87308 Sarstedt Rack Echo 1 each GX87281 Reagent Rack Echo 1 each GX87400 Strip holder Echo 1 each GX87284 Incubator tray (black) Echo 1 each Immucor, Inc. Product Catalogue IG /01 CAT 28
31 Abacus ALS Australia 12 Mowbray Terrace East Brisbane Queensland, AUS, 4169 Ph Fax Abacus ALS New Zealand PO Box SAMC Auckland, NZ Ph Fax Immucor, Inc Gateway Drive (30091) Suite 500 Norcross, GA Abacus ALS Pty Ltd. All rights reserved. All trademarks and images are the property of Immucor, Inc. and its subsidiaries.
Echo. Compact Immunohematology automation. Echo is designed to bring the benefits of automation to labs of all sizes and volumes.
Echo Compact Immunohematology automation Echo is designed to bring the benefits of automation to labs of all sizes and volumes. Transfuse Transplant Transform a life Echo Instrument Map A D B C E I want
More informationSTANDARD OPERATING PROCEDURE FOR THE DIRECT ANTIGLOBULIN TEST
STANDARD OPERATING PROCEDURE FOR THE DIRECT ANTIGLOBULIN TEST TITLE: Standard Operating Procedure for Performing the Direct Antiglobulin Test 1.0 Principle To detect in vivo sensitization of red blood
More informationDirect Antiglobulin Test (DAT)
Exercise 8 Direct Antiglobulin Test (DAT) Objectives: 1. State the purpose for performing the DAT. 2. State what a positive DAT indicates. 3. List the reagents which are used for performing the DAT. 4.
More informationDirect Antiglobulin Test (DAT)
Exercise 8 Exercise 9 Direct Antiglobulin Test (DAT) Elution Study Task Aim Introduction To perform the DAT and elution procedure with correct interpretation of results. To perform with 100% accuracy the
More informationSTANDARD OPERATING PROCEDURE FOR RESOLVING ABO & Rh BLOOD GROUP DISCREPANCIES
STANDARD OPERATING PROCEDURE FOR RESOLVING ABO & Rh BLOOD GROUP DISCREPANCIES TITLE: STANDARD OPERATING PROCEDURE FOR RESOLVING ABO & RH BLOOD GROUP DISCREPANCIES 1.0 Principle 1.1 To resolve ABO and Rh
More informationCORD BLOOD EVALUATION
CORD BLOOD EVALUATION Principle: When there is incompatibility between a mother s antibodies and an infant s red blood cell antigens, the infant is at risk of developing Hemolytic Disease of the Fetus
More informationSerotyping Techniques
Serotyping Techniques Thomas A. Kruzel, M.T., N. D. Southwest College of Naturopathic Medicine & Health Sciences ABO Blood Groups Blood Group RBC Antigens Serum Antibodies Percentage O none Anti A & B
More informationIntroduction. Laboratory Procedure Manual
Exercise 9 Elution Study Objectives: 1. State when an elution procedure may be performed. 2. List four situations in which the performance of an elution may provide helpful information. 3. List three types
More informationUnit 8 Pretransfusion Compatibility Testing
Unit 8 Pretransfusion Compatibility Testing A. The purpose of pretransfusion testing is to select, for each recipient, blood components that, when transfused, will have acceptable survival and will not
More informationStandardization and Evaluation of IgA and IgM Gel Column Agglutination for Direct Antiglobulin Testing
Standardization and Evaluation of IgA and IgM Gel Column Agglutination for Direct Antiglobulin Testing ABSTRACT BACKGROUND: Diagnosis of autoimmune hemolytic anemia is commonly confirmed with a positive
More informationRhD typing. Practice for IV year medical students. Zita Csernus MD. National Blood Transfusion Service Blood Transfusion Centre Pécs
immunisation Bed side test Antibody tests RhD typing Practice for IV year medical students Zita Csernus MD National Blood Transfusion Service Blood Transfusion Centre Pécs Rh Blood Group System Discovery:
More informationAntibody Identification. Part 1. Prerequisites. When Do We I.D.? Part 1: The Basics. A Blood Bank Guy Video Podcast
Antibody Identification Part : The Basics A Blood Bank Guy Video Podcast D. Joe Chaffin, MD March Part Prerequisites Geography of a panel Antibody ID method Case examples Prerequisites When Do We I.D.?
More informationImmunohematology. Immunohematology. Blood Group Antigens
Immunohematology Immunohematology Jeffrey S. Jhang, MD Assistant Director, Transfusion Medicine Demonstration of red cell antigen-red cell antibody reactions is the key to immunohematology Combination
More informationHistory of Innovation
1 History of Innovation Only Immucor consistently delivers the next-generation of blood bank automation to labs worldwide ABS HV Galileo NEO 1998 1999 2004 2007 2010 ABS2000 ABS Precis Echo 2 Innovation
More informationDAT Principle and Application of the DAT DAT Panel Evaluation of a Positive DAT. Case Studies Case 1 Case 2 Factors Affecting the Antiglobulin Test
05Harmening-05 01/17/2005 C H 5:17 PM A Page 93 P T E R five The Antiglobulin Test Ralph E.B. Green, B. App. Sci., FAIMLS, MACE, and Virginia C. Hughes, MS, MT(ASCP)SBB, CLS(NCA)I Introduction Principles
More informationQUICK REFERENCE TO BLOOD BANK TESTING
QUICK REFERENCE TO BLOOD BANK TESTING All Blood bank Tests are performed on demand 24 hours a day, 7 days a week. Feto/Maternal Bleed Quantitation estimates will be available within 4 hours of blood bank
More informationTime Frame 15 minutes. Student should strive to be able to perform multiple procedures simultaneously.
Name Direct Antiglobulin Test (DAT) (Direct Coombs) Principle The DAT detects the in vivo sensitization of RBC with IgG incomplete or non-agglutinating antibodies. After thorough washing of RBC with saline
More informationComparing the Tube and Gel Techniques for ABO Antibody Titration, as Performed in Three European Centers 林 良 豐 100.07.18
Comparing the Tube and Gel Techniques for ABO Antibody Titration, as Performed in Three European Centers 林 良 豐 100.07.18 Introduction Data from 60 consecutive ABO-incompatible kidney transplantations performed
More informationINSTRUCTIONS FOR USE
Blood Grouping Reagent A/B/D Monoclonal and Reverse Grouping Card MTS080515 Intended Use For the performance of a forward and reverse ABO and D antigen grouping on a single Gel Card For use with the ID-Micro
More informationSelecting Appropriate Blood Products for Recipients of ABO/Rh Mismatched Stem Cell Transplants. Summary of Significant Changes. Purpose.
This Specification replaces SPN/DDR/RC/023/05 (SPN215/1) Copy Number Summary of Significant Changes Change to new document reference numbers. Effective 18/10/11 Removal of ABO titres from sections 3.1
More informationVII. Rh Blood Group System
VII. Rh Blood Group System A. The Rh system is one of the most complex genetic systems, and certain aspects of its genetics, nomenclature and antigenic interactions are unsettled. The aim of this lecture
More informationLaboratory Procedure Manual. Rh Phenotyping
Exercise 4 Textbook: Quinley, Chapter 8 Skills: 20 Points Objectives:. State the antigens of the Rh blood group system. 2. Define the terms dominant, codominant, heterozygous, and homozygous as they relate
More informationC. Note that this discussion will be mostly limited to transfusion service actions
(Basic Immunohematology Part 2) February 2012 D. Joe, MD www.bbguy.org I. Outline: A. Overview of pretransfusion testing B. Testing methods C. Required components of the process D. Nomenclature of tests
More informationBlood Typing Laboratory Exercise 40
Blood Typing Laboratory Exercise 40 Background Blood typing involves identifying protein substances called antigens that are present in red blood cell membranes. Although there are many different antigens
More informationHiPer Blood Grouping Teaching Kit
HiPer Blood Grouping Teaching Kit Product Code: HTI008 Number of experiments that can be performed: 100 Duration of Experiment: Protocol: 15 minutes Storage Instructions: The kit is stable for 6 months
More informationBlood Grouping Reagent DG Gel 8 ABO/Rh + Kell REF 210383 3034946
Blood Grouping Reagent DG Gel 8 ABO/Rh + Kell REF 210383 3034946 Instructions for Use INTENDED USE The DG Gel 8 ABO/Rh + Kell card is for the determination of ABO forward and reverse group, and D and K
More informationVI. ABO and H Blood Groups
MLAB 243 4 A. History of ABO System. Discovered in 900 by Karl Landsteiner and remains the most important of the blood group systems as far as the transfusion of blood is concerned. 2. Landsteiner tested
More informationIgM ELISA. For the quantitative determination of IgM in human serum and plasma. For Research Use Only. Not For Use In Diagnostic Procedures.
IgM ELISA For the quantitative determination of IgM in human serum and plasma For Research Use Only. Not For Use In Diagnostic Procedures. Please read carefully due to Critical Changes, e.g., Calibrator
More informationTHE Rh BLOOD GROUP SYSTEM
CHAPTER 10 THE Rh BLOOD GROUP SYSTEM CONNIE WESTHOFF OBJECTIVES After completion of this chapter, the reader will be able to: 1. Describe the Rh system antigens, including: a. The alleles inherited at
More informationEDUCATIONAL COMMENTARY ANTIBODY TITRATIONS
EDUCATIONAL COMMENTARY ANTIBODY TITRATIONS Educational commentary is provided through our affiliation with the American Society for Clinical Pathology (ASCP). To obtain FREE CME/CMLE credits click on Earn
More informationBasic Immunologic Procedures. Complex Serological Tests
Basic Immunologic Procedures Complex Serological Tests Amal Alghamdi 2014-2015 1 Classification of antigen-antibody interactions: 1. Primary serological tests: (Marker techniques) e.g. Enzyme linked immuonosorben
More informationHemolysis. Intravascular vs. Extravascular. Classification. Warm vs. Cold Auto. Warm Auto. WAIHA Serologic Investigation
Positive Direct Antiglobulin Test and Autoimmune Hemolytic Anemias Jeffrey S. Jhang, M.D. Assistant Professor of Clinical Pathology College of Physicians and Surgeons of Columbia University Direct Antiglobulin
More informationRh Immune Globulin Workup (RhIgW)
Exercise 10 Rh Immune Globulin Workup (RhIgW) 1. State the purpose for giving Rh Immune Globulin (RhIg). 2. State the population which is most frequently given RhIg. 3. State the severity of HDFN. 4. State
More informationGuidance manual on ABO and Rh blood grouping
NIB/BRL/GM/02 Guidance manual on ABO and Rh blood grouping NATIONAL INSTITUTE OF BIOLOGICALS (Ministry of Health & Family Welfare) Government of India A-32, Sector -62, Institutional Area NOIDA- 201307
More informationCan receive blood from: * I A I A and I A i o Type A Yes No A or AB A or O I B I B and I B i o Type B No Yes B or AB B or O
Genetics of the ABO Blood Groups written by J. D. Hendrix Learning Objectives Upon completing the exercise, each student should be able: to explain the concept of blood group antigens; to list the genotypes
More informationDEPARTMENT OF CLINICAL LABORATORY SCIENCES SCHOOL OF HEALTH TECHNOLOGY AND MANAGEMENT THE UNIVERSITY AT STONY BROOK STONY BROOK, NEW YORK 11794-8205
DEPARTMENT OF CLINICAL LABORATORY SCIENCES SCHOOL OF HEALTH TECHNOLOGY AND MANAGEMENT THE UNIVERSITY AT STONY BROOK STONY BROOK, NEW YORK 11794-8205 IMMUNOHEMATOLOGY COMPETENCY EVALUATION FORM STUDENT
More informationMouse IgM ELISA. Cat. No. KT-407 K-ASSAY. For the quantitative determination of IgM in mouse biological samples. For Research Use Only. 1 Rev.
K-ASSAY Mouse IgM ELISA For the quantitative determination of IgM in mouse biological samples Cat. No. KT-407 For Research Use Only. 1 Rev. 072309 K-ASSAY PRODUCT INFORMATION Mouse IgM ELISA Cat. No. KT-407
More informationSome Immunological Test. Presented by Alaa Faeiz Ashwaaq Dyaa Aseel Abd AL-Razaq Supervised by D.Feras
Some Immunological Test Presented by Alaa Faeiz Ashwaaq Dyaa Aseel Abd AL-Razaq Supervised by D.Feras Alaa Faeiz Antigen -Antibody Reactions. Antigen antibody reactions are performed to determine the presence
More informationABORhCard. ABORhCard Package Insert ABO and Rh Blood Grouping Device
ABORhCard Package Insert ABO and Rh Blood Grouping Device ABORhCard Intended Use The ABORhCard is a qualitative in vitro test that provides a simultaneous ABO and Rh determination of an individual s ABO
More informationSafe Blood and Blood Products
Safe Blood and Blood Products Module 3 Blood Group Serology Safe Blood and Blood Products Module 3 Blood Group Serology Conversion of electronic files for the website edition was supported by Cooperative
More informationWHO Prequalification of Diagnostics Programme PUBLIC REPORT. Product: Genscreen ULTRA HIV Ag-Ab Number: PQDx 0096-031-00. Abstract
WHO Prequalification of Diagnostics Programme PUBLIC REPORT Product: Genscreen ULTRA HIV Ag-Ab Number: PQDx 0096-031-00 Abstract Genscreen ULTRA HIV Ag-Ab with product codes 72386 and 72388, manufactured
More informationBlood Physiology. Practical 4. Contents. Practical tasks. Erythrocytes The blood types
Blood Physiology Practical 4 Contents Erythrocytes The blood types Practical tasks Determination of blood groups of the ABO system Determination of the Rhesus system (Rh factor) The cross matching test
More informationBlood-Based Cancer Diagnostics
The Biotechnology Education Company Blood-Based Cancer Diagnostics EDVO-Kit 141 Store entire experiment at room temperature. EXPERIMENT OBJECTIVE: The objective of this experiment is to learn and understand
More informationCold Agglutination Titer detecting Cold Reacting Antibodies
Objectives: Cold Agglutination Titer detecting Cold Reacting Antibodies 1. Perform a serial dilution to determine the amount of cold reacting antibody present in a patient specimen with the results obtained
More information1. BLOOD GROUP SYSTEMS. Page 1. Haematology LECTURE 10. BLOOD GROUPS AND TRANSFUSIONS OVERVIEW. 1. Blood Group Systems
Undergraduate Course in Veterinary Clinical PathologySocrates Programme Haematology LECTURE 10. BLOOD GROUPS AND TRANSFUSIONS 10-1 OVERVIEW 1. Blood Group Systems 2. Blood group testing and cross-matching
More informationBlood Group Incompatibility
Joyce Poole, International Blood Group Reference Laboratory, Bristol, UK Blood group antibodies present in plasma can bind with blood group antigens on red cells and cause a reaction (blood group incompatibility).
More informationLAB 14 ENZYME LINKED IMMUNOSORBENT ASSAY (ELISA)
STUDENT GUIDE LAB 14 ENZYME LINKED IMMUNOSORBENT ASSAY (ELISA) GOAL The goal of this laboratory lesson is to explain the concepts and technique of enzyme linked immunosorbent assay (ELISA). OBJECTIVES
More informationDengue IgM ELISA. For the quantitative determination of IgM-class antibodies to Dengue Virus in serum.
Dengue IgM ELISA For the quantitative determination of IgM-class antibodies to Dengue Virus in serum. For Research Use Only. Not For Use In Diagnostic Procedures. Catalog Number: 20-DEMHU-E01 Size: 96
More informationValidation of column agglutination technology for blood group alloantibody titration
Validation of column agglutination technology for blood group alloantibody titration Melanie J Adriaansen and Holly E Perry Abstract Objective: To compare the performance of column agglutination technology
More informationABORhCard Applications and Performance Studies White Paper
ABORhCard Applications and Performance Studies White Paper Contents Background....................................... 2 ABORhCard Simple, Accurate, Fast Blood Typing....... 2 Product Design....................................
More informationABO-Rh Blood Typing With Synthetic Blood
70-0101 ABO-Rh Blood Typing With Synthetic Blood Teacher s Manual World-Class Support for Science & Math The ability to type blood is an invaluable tool in the fields of medicine and criminology. Using
More informationHow Does a Doctor Test for AIDS?
Edvo-Kit #S-70 How Does a Doctor Test for AIDS? S-70 Experiment Objective: The Human Immunodefi ciency Virus (HIV) is an infectious agent that causes Acquired Immunodefi ciency Syndrome (AIDS) in humans.
More informationAffi-Prep Protein A Matrix Instruction Manual
Affi-Prep Protein A Matrix Instruction Manual Catalog Numbers 156-0005 156-0006 Bio-Rad Laboratories, 2000 Alfred Nobel Dr., Hercules, CA 94547 LIT-230 Rev B Table of Contents Section 1 Introduction...1
More informationImmunohematology JOURNAL OF BLOOD GROUP SEROLOGY AND EDUCATION
Immunohematology JOURNAL OF BLOOD GROUP SEROLOGY AND EDUCATION V OLUME 22, NUMBER 2, 2006 Immunohematology JOURNAL OF BLOOD GROUP SEROLOGY AND EDUCATION VOLUME 22, NUMBER 2, 2006 C O N T E N T S 47 With
More informationClassic Immunoprecipitation
292PR 01 G-Biosciences 1-800-628-7730 1-314-991-6034 technical@gbiosciences.com A Geno Technology, Inc. (USA) brand name Classic Immunoprecipitation Utilizes Protein A/G Agarose for Antibody Binding (Cat.
More informationGuidelines for pre-transfusion compatibility procedures in blood transfusion laboratories.
Guidelines for pre-transfusion compatibility procedures in blood transfusion laboratories. British Committee for Standards in Haematology Address for correspondence: BCSH Secretary British Society for
More informationXV.Quality Assurance in the Blood Bank
XV.Quality Assurance in the Blood Bank A. Overview 1. Goals 2. Terms B. Record Keeping a. Safe transfusion b. Careful adherence to SOPs by trained personnel c. Develop comprehensive guidelines to be in
More information510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY
A. 510(k) Number: K092353 510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY B. Purpose for Submission: This is a new 510k application for a new indication for the MONOLISA Anti-HAV IgM EIA
More informationDirect Testing Systems and Serology
Direct Testing Systems and Serology Rapid Manual Tests 6-2 Serology Diagnostics 6-6 BD Diagnostics Diagnostic Systems Catalog 2005/2006 6-1 Rapid Manual Tests Meningitis Test Systems 252360 Directigen
More informationMLT 118L Clinical Immunology/Immunohematology Lab
Page 1 of 5 MLT 118L Clinical Immunology/Immunohematology Lab Approval Date: Effective Term: Department: MEDICAL LABORATORY TECHNICIAN Division: Allied Health/Public Safety Units: 1.00 Grading Option:
More informationMouse Creatine Kinase MB isoenzyme (CKMB) ELISA
KAMIYA BIOMEDICAL COMPANY Mouse Creatine Kinase MB isoenzyme (CKMB) ELISA For the quantitative determination of mouse CKMB in serum, plasma, cell culture fluid and other biological fluids Cat. No. KT-57681
More informationREQUEST FOR TESTING TRANSFUSION SERVICES
REQUEST FOR TESTING TRANSFUSION SERVICES 921 Terry Avenue Seattle, WA 98104-1256 TO REORDER FORMS CALL 425-656-3019 PSBC Tech PSBC ID / CL # Time Received See the back of this order form for sample requirements.
More informationCharacteristics and Serologic Determination of Antibodies to High Frequency Antigens
Characteristics and Serologic Determination of Antibodies to High Frequency Antigens Nicole Thornton The International Blood Group Reference Laboratory Bristol, United Kingdom. 23 rd Regional Congress
More informationValidation. Richard Haggas Quality Manager, Blood Transfusion Department Leeds and Bradford Teaching Hospitals
Validation. Richard Haggas Quality Manager, Blood Transfusion Department Leeds and Bradford Teaching Hospitals What do we mean by validation? The establishment of documented and objective evidence that
More information06-6542 n/a MYSTERY OF THE BLOOD STAIN (RE)
DATA SHEET Order code Manufacturer code Description 06-6542 n/a MYSTERY OF THE BLOOD STAIN (RE) The enclosed information is believed to be correct, Information may change without notice due to product
More informationDot Blot Analysis. Teacher s Guidebook. (Cat. # BE 502) think proteins! think G-Biosciences www.gbiosciences.com
PR110 G-Biosciences 1-800-628-7730 1-314-991-6034 technical@gbiosciences.com A Geno Technology, Inc. (USA) brand name Dot Blot Analysis Teacher s Guidebook (Cat. # BE 502) think proteins! think G-Biosciences
More informationAntigens & Antibodies II. Polyclonal antibodies vs Monoclonal antibodies
A Brief Review of Antibody Structure A Brief Review of Antibody Structure The basic antibody is a dimer of dimer (2 heavy chain-light chain pairs) composed of repeats of a single structural unit known
More informationABO-Rh Blood Typing Using Neo/BLOOD
ABO-Rh Blood Typing Using Neo/BLOOD Objectives Determine the ABO and Rh blood type of unknown simulated blood samples. Prepare a simulated blood smear. Examine a prepared blood smear under the microscope
More informationRPCI 004 v.002 Staining Procedure For all Directly Conjugated Reagents (Whole Blood Method)
Immune Tolerance Network RPCI 004 v.002 Staining Procedure For all Directly Conjugated Reagents (Whole Blood Method) Author: Paul Wallace, Director, RPCI Laboratory of Flow Cytometry Approved by: Paul
More informationOptimal Conditions for F(ab ) 2 Antibody Fragment Production from Mouse IgG2a
Optimal Conditions for F(ab ) 2 Antibody Fragment Production from Mouse IgG2a Ryan S. Stowers, 1 Jacqueline A. Callihan, 2 James D. Bryers 2 1 Department of Bioengineering, Clemson University, Clemson,
More informationChapter 18. Blood Types
Chapter 18 Blood Types Blood Types blood types and transfusion compatibility are a matter of interactions between plasma proteins and erythrocytes Karl Landsteiner discovered blood types A, B and O in
More informationAuthor: Stephanie Skibby, HLA Laboratory, Inland Northwest Blood Center, Spokane, WA
Chapter 1: Serology Chapter 3: Flow Cytometry/Luminex Section: Technical Modules Module: (a) Serum Preparation Author: Stephanie Skibby, HLA Laboratory, Inland Northwest Blood Center, Spokane, WA Date
More informationTopic: Serological reactions: the purpose and a principle of reactions. Agglutination test. Precipitation test. CFT, IFT, ELISA, RIA.
Topic: Serological reactions: the purpose and a principle of reactions. Agglutination test. Precipitation test. CFT, IFT, ELISA, RIA. Serology is the study and use of immunological tests to diagnose and
More informationLab 02: Blood Cytology (20 points)
Pierce College Putman/Biol 242 Name: Lab 02: Blood Cytology (20 points) Reference: Marieb & Mitchell 9 th Ed: 29A (Activities 1, 2, 3, 4, 7); 10 th Ed: Exercise 29 (Activities 1, 2, 3, 4, 7). Pierce College
More informationSAMPLE COLLECTION MANUAL. NZBS Blood Banks and NZBS Reference Laboratory
SAMPLE COLLECTION MANUAL NZBS Blood Banks and NZBS Reference July 2012 SECTION 1. INTRODUCTION 3 SECTION 2. PRETRANSFUSION TESTING 3 2.1 COMPLETION OF REQUEST FORM... 3 2.2 SAMPLE COLLECTION... 4 2.3 SAMPLE
More informationCHAPTER 10 BLOOD GROUPS: ABO AND Rh
CHAPTER 10 BLOOD GROUPS: ABO AND Rh The success of human blood transfusions requires compatibility for the two major blood group antigen systems, namely ABO and Rh. The ABO system is defined by two red
More informationMalondialdehyde (MDA) ELISA
Malondialdehyde (MDA) ELISA For the quantitative determination of MDA in serum, plasma and other biological fluids Cat. No. KT-21493 For Research Use Only. Not for use in diagnostic procedures. Page 1
More informationEDUCATIONAL COMMENTARY WARM AUTOANTIBODIES AND TRANSFUSION
EDUCATIONAL COMMENTARY WARM AUTOANTIBODIES AND TRANSFUSION Educational commentary is provided through our affiliation with the American Society for Clinical Pathology (ASCP). To obtain FREE CME/CMLE credits
More informationBlood Sticky, opaque fluid with a metallic taste (Fe 2+ ) Varies from scarlet (P O2 = 100) to dark red (P O2 = 40) ph is between 7.35 and 7.45 Average volume in an adult is 5 L (7% of body weight) 2 L
More informationLIAISON XL HBsAg Quant
Hepatitis and Retrovirus LIAISON XL HBsAg Quant Reliable detection of HBsAg mutants and genotypes for accurate differential diagnosis of the stage of infection FOR OUTSIDE THE US AND CANADA ONLY LIAISON
More informationRealLine HCV PCR Qualitative - Uni-Format
Instructions for use PCR KIT FOR EXTRACTION OF RNA AND REAL TIME PCR DETECTION KIT FOR HEPATITIS C VIRUS RNA Research Use Only Qualitative Uni Format VBD0798 48 tests valid from: December 2013 Rev11122013
More informationQuickTiter FeLV Core Antigen ELISA Kit (FeLV p27)
Product Manual QuickTiter FeLV Core Antigen ELISA Kit (FeLV p27) Catalog Numbers VPK-155 96 wells FOR RESEARCH USE ONLY Not for use in diagnostic procedures Introduction Feline leukemia virus (FeLV) is
More informationRat creatine kinase MM isoenzyme (CK-MM) ELISA Kit
Rat creatine kinase MM isoenzyme (CK-MM) ELISA Kit Catalog Number. CSB-E14405r For the quantitative determination of rat creatine kinase MM isoenzyme (CK-MM) concentrations in serum, plasma and tissue
More information2nd Ed. 2004. Prepared by. Scientific Subcommittee of the Australian & New Zealand Society of Blood Transfusion Inc
G u i d e l i n e s f o r B l o o d G r o u p i n g & A n t i b o d y S c r e e n i n g i n t h e A n t e n a t a l & P e r i n a t a l S e t t i n g 2nd Ed. 2004 Prepared by Scientific Subcommittee of
More informationLAB 1 - Direct agglutination. Serology-the study of the in vitro reactions between antibody and antigen
LAB 1 - Direct agglutination Serology-the study of the in vitro reactions between antibody and antigen Serological reaction: - quantitative (weight/volume) - qualitative Agglutination - the aggregation
More informationFor the development of sandwich ELISAs to measure phosphorylated Epidermal Growth Factor Receptor (EGF R) in cell lysates.
DuoSet IC Human Phospho-EGF R Catalog Number DYC1095-2 Catalog Number DYC1095-5 For the development of sandwich ELISAs to measure phosphorylated Epidermal Growth Factor Receptor (EGF R) in cell lysates.
More informationInc. Wuhan. Quantity Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4 Standard (liquid) 2
Uscn Life Science Inc. Wuhan Website: www.uscnk.com Phone: +86 27 84259552 Fax: +86 27 84259551 E-mail: uscnk@uscnk.com ELISA Kit for Human Prostaglandin E1(PG-E1) Instruction manual Cat. No.: E0904Hu
More informationHepatitis and Retrovirus. LIAISON XL Accurate detection of HIV infection. HIV Ab/Ag FOR OUTSIDE THE US AND CANADA ONLY
Hepatitis and Retrovirus LIAISON XL Accurate detection of HIV infection HIV Ab/Ag FOR OUTSIDE THE US AND CANADA ONLY LIAISON XL HIV Ab/Ag is Your solution LIAISON XL murex HIV Ab/Ag main features The LIAISON
More informationRat creatine kinase MM isoenzyme (CK-MM) ELISA Kit
Rat creatine kinase MM isoenzyme (CK-MM) ELISA Kit Catalog Number. CSB-E14405r For the quantitative determination of rat creatine kinase MM isoenzyme (CK-MM) concentrations in serum, plasma, tissue homogenates.
More informationAntibodies to Low-Incidence Antigens in the MNS Blood Group System. Antibodies to High-Incidence Antigens in the MNS Blood Group System
Blood Group Systems Page 1 [Start with listings with each line having hyperlink to full section in the rest of this document.] ABO BLOOD GROUP SYSTEM Anti-A. Anti-B Anti-A 1 MNS BLOOD GROUP SYSTEM Anti-M
More informationAnswers to Your Questions About Blood Bank Proficiency, Competency and QC Follow Up to April 28, 2016 Webinar
Answers to Your Questions About Blood Bank Proficiency, Competency and QC Follow Up to April 28, 2016 Webinar Anne Chenoweth, MBA, MT(ASCP)CM, CQA(ASQ) Director, Accreditation and Quality AABB Stacy Olea,
More informationComparison of test tube, gel column agglutination and solid phase red cell adherence methods
Comparison of test tube, gel column agglutination and solid phase red cell adherence methods with and without drug added for detection of drug-dependent antibodies Phyllis Kirchner, MT(ASCP)SH, SBB ABSTRACT
More informationGuidelines For Setting up Blood Storage Centres
Guidelines For Setting up Blood Storage Centres National AIDS Control Organisation Ministry of Health and Family Welfare Government of India New Delhi 2007 Produced and published by National AIDS Control
More informationImmunohematology Journal of Blood Group Serology and Molecular Genetics Volume 30, Number 3, 2014
Journal of Blood Group Serology and Molecular Genetics V o l u m e 3 0, N u m b e r 3, 2014 Immunohematology Journal of Blood Group Serology and Molecular Genetics Volume 30, Number 3, 2014 CONTENTS 113
More informationSTANDARD OPERATING PROCEDURE
STANDARD OPERATING PROCEDURE Title: Antibody Production at Strategic Diagnostics Inc. SOP#: M-119 Version #: 1 Date Approved: August 6, 2009 Author: Strategic Diagnostic Inc. Date Modified: 1. PURPOSE
More informationMouse krebs von den lungen 6 (KL-6) ELISA
KAMIYA BIOMEDICAL COMPANY Mouse krebs von den lungen 6 (KL-6) ELISA For the quantitative determination of mouse KL-6 in serum, plasma, cell culture supernatants, body fluid and tissue homogenate Cat. No.
More informationBLOOD GROUP ANTIGENS AND ANTIBODIES
BLOOD GROUP ANTIGENS AND ANTIBODIES Over 20 blood group systems having approximately 400 blood group antigens are currently recognised. The ABO and Rhesus (Rh) blood group systems are of major clinical
More informationT100. BioTube Rack. Rack is made of 3 components: A white base A removable grid plate that can hold individual or strips of tubes A translucent cover
BiotubeTM System Simport offers a wide choice of racks containing 96 x 1.2 ml tubes (8.8 mm top dia. x 45 mm H, or strips of 8 or 12. Tubes, strips, caps and boxes are available as separate units as well.
More informationBody Fluids. What is Serology? Blood. Introduction
Body Fluids Forensic Serology Introduction Prior to the development of DNA typing, forensic serology was the primary technique of crime labs. Most labs still use basic serological testing procedures. Some
More informationMYCOLOGY PARASITOLOGY RHEUMATOID FACTORS VIROLOGY SAMPLE COLLECTION
C A T A L O G U E C L I N I C A L D I A G N O S T I C S couv BACTERIOLOGYOGY MYCOLOGY PARASITOLOGY RHEUMATOID FACTORS VIROLOGY SAMPLE COLLECTION couv EXPORT DEPARTMENT Orders, technical and commercial