Serial Port Connections
|
|
- Egbert Pearson
- 7 years ago
- Views:
Transcription
1 Serial Port Connections PORT 5 RS PORT RS45 Providing Power to an External Device from Port If either port is set up for communications with a serial device that requires 00mA or less at 5VDC, the device can obtain power from Port. Cable Lengths and Baud Rates Maximum cable lengths (the total number of feet from the CPU to the last device attached to the cable) are: Port (RS-) = 5 meters (50 ft.) Port (RS-45) = 00 meters (4000 ft.) Both ports support configurable baud rates, as listed in the CPU descriptions in this manual. The following pre-assembled cables are available: IC00CBL00 IC00CBL00 CPU Programming Cable RS Expansion Firmware Upgrade Cable 4- VersaMax PLC User's Manual March 00 GFK-50C
2 Port : RS- Pin Assignments for Port Port is an RS- port with a 9-pin female D-sub connector. It is used as the boot loader port for upgrading the CPU firmware. The pinout of Port allows a simple straight-through cable to connect with a standard AT-style RS- port. Cable shielding attaches to the shell. Pin Signal Direction Function n/c TXD Output Transmit Data output RXD Input Receive Data input 4 n/c 5 GND 0V/GND signal reference 6 n/c 7 CTS Input Clear to Send input RTS Output Request to Send output 9 n/c Shell SHLD Cable Shield wire connection / 00% (Continuous) shielding cable shield connection RS- Point to Point Connection In point-to-point configuration, two devices are connected to the same communication line. For RS-, the maximum length is 5 meters (50ft) PC 9-Pin CPU Serial Port Port 9-pin female 9-pin male () RXD () TXD () TXD () RXD (5) GND (5) GND (7) RTS (7) CTS () CTS () RTS The shield must connect to shell of connectors on both ends of the cable. GFK-50C Chapter 4 Installation 4-
3 and Cable Specifications for Port Vendor Part numbers below are provided for reference only. Any part that meets the same specification can be used. Cable: Belden Pin Male : Shell: Computer cable, overall braid over foil shield 5 conductor 0 Volt / 0 C (76 F) 4 AWG tinned copper, 7x stranding Type: Crimp Solder Vendor: Plug: DEA9PK7F ZDE9P Pin: Kit * ITT Cannon DE07-54 [9-pin size backshell kit]: Metal-Plated Plastic (Plastic with Nickel over Copper) Cable Grounding Clamp (included) 40 cable exit design to maintain low-profile installation Plus ITT Cannon [Extended Jackscrew]: Threaded with #4-40 for secure attachment to CPU00 port Order Qty for each cable shell ordered Critical Information any other part selected should meet or exceed this criteria. * Use of this kit maintains the 70mm installed depth. 4-4 VersaMax PLC User's Manual March 00 GFK-50C
4 Port : RS-45 Pin Assignments for Port Port is an RS-45 port with a 5-pin female D-sub connector. This can be attached directly to an RS-45 to RS- adapter. Pin Signal Direction Function SHLD Cable Shield Drain wire connection,, 4 n/c 5 P5V Output +5.VDC to power external devices (00mA max.) 6 RTSA Output Request to Send (A) output 7 GND 0V/GND reference signal CTSB Input Clear to Send (B) input 9 RT Resistor Termination (0 ohm) for RDA 0 RDA Input Receive Data (A) input RDB Input Receive Data (B) input SDA Output Transmit Data (A) output SDB Output Transmit Data (B) output 4 RTSB Output Request to Send (B) output 5 CTSA Input Clear to Send (A) input Shell SHLD Cable Shield wire connection / 00% (Continuous ) shielding cable shield connection and Cable Specifications for Port Vendor Part numbers below are provided for reference only. Any part that meets the same specification can be used. Cable: Belden 05 5 Pin Male : Shell: Low Capacitance Computer cable, overall braid over foil shield 5 Twisted-pairs Shield Drain Wire 0 Volt / 0 C (76 F) 4 AWG tinned copper, 7x stranding Velocity of Propagation = 7% Nominal Impedance = 00Ω Type: Crimp Solder Vendor: Plug: DAA5PK7F ZDA5P Pin: Kit* ITT Cannon DA07-50 [5-pin size backshell kit]: Metal-Plated Plastic (Plastic with Nickel over Copper) Cable Grounding Clamp (included) 40 cable exit design to maintain low-profile installation Plus ITT Cannon [Extended Jackscrew]: Threaded with (metric) Mx0.5 for secure attachment Order Qty for each cable shell ordered Critical Information any other part selected should meet or exceed this criteria. GFK-50C Chapter 4 Installation 4-5
5 RS-45 Point to Point Connection with Handshaking In point-to-point configuration, two devices are connected to the same communication line. For RS-45, the maximum cable length is 00 meters (4000 feet). Modems can be used for longer distances. Computer RD ( A' ) RD ( B' ) SD ( A ) SD ( B ) CTS ( A' ) CTS ( B' ) RTS ( B ') RTS ( A ) GND SHLD Shielded Twisted Pairs Up to 5. meters (50 ft) without isolation PLC SD ( A ) SD ( B ) RD ( A' ) RD ( B ' ) RT RTS ( A ) RTS ( B ) CTS ( B' ) CTS ( A' ) GND SHLD 4-6 VersaMax PLC User's Manual March 00 GFK-50C
6 RS-45 Multidrop Serial Connections In the multidrop configuration, the host device is configured as the master and one or more PLCs are configured as slaves. The maximum distance between the master and any slave may not exceed 4000 feet (00 meters). This figure assumes good quality cables and a moderately noisy environment. A maximum of slaves can be connected using RS-45 in a daisy chain or multidrop configuration. The RS-45 line must include handshaking and use wire type as specified earlier. Master Slave Station Last Station When wiring RS-45 multidrop cables, reflections on the transmission line can be reduced by daisy-chaining the cable as shown below. Make connections inside the connector to be attached to the PLC. Avoid using terminal strips to other types of connectors along the length of the transmission line. Computer RS- Port 9 Pin Male RD TD RTS 7 CTS DCD DTR 4 GND 5 9-Pin Female to 5- Pin Male RS- Shielded Cable (NC) RD TD 5 CTS 0 DTR DCD 7 GND SHLD RS-/RS-45 Converter IC690ACC900 DCD(A) DCD(B) RD(A ) 0 RD(B ) SD(A) SD(B) RT 9 CTS(A ) 5 CTS(B ) RTS(A) 6 RTS(B) 4 +5V 5 0V 7 SHLD RS-45 Cables Make connections inside D-connectors SD(A) SD(B) 0 RD(A ) RD(B ) 9 RT 6 RTS(A) 4 RTS(B) 5 CTS(A ) CTS(B ) 5 +5V 7 0V SHLD CPU RS-45 Port 5 Pin Female 5-5- FEMALE FEMALE RS- RS-45 PORT PORT Power Source for Converter. Must be wired no less than meters (0 feet) from the converter. 5- MALE 5V 0V TO OTHER PLC's Termination resistance for the Receive Data (RD) signal must be connected only on units at the ends of lines. This termination is made at the CPU by connecting a jumper between pin 9 and pin 0 inside the D-shell connector. Ground Potential: Multiple units not connected to the same power source must have common ground potential or ground isolation for proper operation of the system. GFK-50C Chapter 4 Installation 4-7
Modbus RTU Master Communications
Modbus RTU Master Communications This document describes the operation of Modbus RTU Master from the user interface point of view. Use this information as a supplement to the Serial Communications User
More informationData Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.
Data Bulletin 1210DB0002R3/05 03/2005 LaVergne, TN, USA Communications Wiring for POWERLINK G3 Systems Class 1210 Retain for future use. ABOUT THIS BULLETIN This data bulletin describes the proper wiring
More informationMoxa TCC-100/100I User s Guide
Moxa TCC-100/100I User s Guide Seventh Edition, June 2008 www.moxa.com/product 2008 Moxa Inc., all rights reserved. Reproduction without permission is prohibited. Moxa TCC-100/100I User s Guide The software
More informationCable Guide. Click on the subject to view the information. Digi Cables Building Cables General Cable Information
Cable Guide Click on the subject to view the information. Digi Cables Building Cables General Cable Information Digi Cables Click on the subject to view the information. Digi Connector Options Digi Connector
More informationRS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: 91-79-4002 4896 / 97 / 98 (M) 0-98253-50221 www.interfaceproducts.info
RS232C < - > RS485 CONVERTER S MANUAL Model: LD15U INTRODUCTION Milestone s model LD-15U is a RS232 to RS 485 converter is designed for highspeed data transmission between computer system and or peripherals
More informationRJ45 Shielded (standard) port pinout. CS9000, Jetstream 4000 + 8500, Lanstream 2000, RTA8/RJX, RRC16, MTA8/RJX & SXDC8/RJX
Shielded (standard) port pinout Pin Circuit Function 1 DCD Input Data Carrier Detect 2 DSR Output Data Set Ready 3 DTR Input Data Terminal Ready 4 S/GND Signal Ground 5 TXD Output Transmit Data 6 RXD Input
More informationCable Pinouts. SRP I/O Module
Cable Pinouts C This appendix lists the cables and connector pinout assignments for the cables used with the ERX-700 series and ERX-1400 series. Topic Page SRP I/O Module C-1 CT1 and CE1 I/O Modules C-4
More informationConnector and Cable Specifications
APPENDIXB This chapter describes the connector and cable specifications. Connector Specifications, page B-1l Cable and Adapter Specifications, page B-5 Connector Specifications 10/100/1000 Ports, page
More informationCable Specifications. T3 Trunk Cabling APPENDIX
APPENDIX B This appendix contains details on the MGX 8230 cabling. It includes the following sections: T3 Trunk Cabling Frame Relay Cabling DC Power Cabling AC Power Cabling Control and Clock Cabling External
More informationComputer Control of Satellite Antennas
Computer Control of Satellite Antennas This paper discusses the use of the serial interface available on Research Concepts, Inc. (RCI) satellite antenna controllers. The serial communications interface
More informationRS-232 COMMUNICATIONS
Technical Note D64 0815 RS-232 COMMUNICATIONS RS-232 is an Electronics Industries Association (EIA) standard designed to aid in connecting equipment together for serial communications. The standard specifies
More informationComtrol Cable User Guide
Comtrol Cable User Guide Trademark Notices Comtrol and DeviceMaster are trademarks of Comtrol Corporation. PortVision is a registered trademark of Comtrol Corporation. Microsoft and Windows are registered
More informationMDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE. USER GUIDE Document reference : 9010709-03
MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE USER GUIDE Document reference : 9010709-03 If you have questions about the MDM192 or desire assistance, contact ETIC TELECOMMUNICATIONS at the following
More informationTable of Contents. Page Number. PLC Connections 1 Cable Solutions for Omron PLCs 11 Cable Solutions for Multi-Vendor PLCs 15
Table of Contents Name Page Number PLC Connections 1 Cable Solutions for Omron PLCs 11 Cable Solutions for Multi-Vendor PLCs 15 i Reference Information PLC Connections The following pages illustrate the
More informationCable Specifications and Information
APPENDIX A This appendix provides the connector and pinout information you need for making or purchasing cables used with Cisco VG224 voice gateway. To order cables from Cisco, see the Obtaining Technical
More informationFOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology
FOSTCDR pn 8684R1 FOSTCDR-0812ds page 1/5 Industrial Serial to Multimode Fiber Optic Converter Data Rates up to 115.2 kbps 2.5 Mile (4 km) Range 10 to 30 VDC Input Voltage Wide Operating Temperature 2000V
More informationManual Serial PCI Cards
Manual Serial PCI Cards W&T Models 13011, 13410 13411, 13610 13611, 13812 Version 1.4 Subject to error and alteration 37 01/2005 by Wiesemann & Theis GmbH Subject to errors and changes: Since we can make
More informationModbus RTU Master Communications
Modbus RTU Master Communications This document describes the operation of Modbus RTU Master from the user interface point of view. Use this information as a supplement to the Serial Communications User
More informationHSG Engineering Tech Bulletin
Specifications subject to change OCT 2013; Rev. 1.3 HSG Engineering Tech Bulletin Recommended RS-485 Wiring for NetAXS-4/NetAXS-123 Loops Overview This document provides the recommended RS-485 wiring for
More informationCable Guide Including all PortServer TS, Digi Connect, and Digi One Products
Cable Guide Including all PortServer TS, Digi Connect, and Digi One Products 90000253_E Digi International Inc. 2005. Digi, Digi International, the Digi logo, the Making Device Networking Easy logo, Digi
More informationCable Specifications and Information
APPENDIXA This appendix provides the connector and pinout information you need for making or purchasing cables used with Cisco VG350 Voice Gateway. To order cables from Cisco, see the Obtaining Technical
More informationConnectors and Cables
APPENDIX B This appendix describes the connectors, cables, and adapters that you use to connect the switch to other devices. Connector Specifications 10/100 Ports The 10/100 Ethernet ports use standard
More information1-Port R422/485 Serial PCIe Card
1-Port R422/485 Serial PCIe Card Installation Guide 1. Introduction Thank you for purchasing this 1-Port RS422/485 Serial PCI Express (PCIe) Card. It is a universal add in card that connects to a PC or
More informationALL-USB-RS422/485. User Manual. USB to Serial Converter RS422/485. ALLNET GmbH Computersysteme 2015 - Alle Rechte vorbehalten
ALL-USB-RS422/485 USB to Serial Converter RS422/485 User Manual ALL-USB-RS422/485 USB to RS-422/485 Plugin Adapter This mini ALL-USB-RS422/485 is a surge and static protected USB to RS-422/485 Plugin Adapter.
More informationOPT-700 - SERIAL TO FIBER OPTIC CONVERTER
USER S MANUAL OPT-700 - SERIAL TO FIBER OPTIC CONVERTER JUL / 05 OPT-700 VERSION 1 TM FOUNDATION OPT700ME smar www.smar.com Specifications and information are subject to change without notice. Up-to-date
More informationParagon Explorer Lite Communication Software
CU-111 APRIL 11, 2013 Paragon Explorer Lite Communication Software For Fireye Paragon Scanners using Windows XP DESCRIPTION Paragon Explorer Lite, is the basic PC based configuration tool for Paragon model
More informationPCMCIA 1 Port RS232 2.1 EDITION OCTOBER 1999
232 232232 PCMCIA 1 Port RS232 2.1 EDITION OCTOBER 1999 Guarantee. FULL 36 MONTHS GUARANTEE. We guarantee your interface card for a full 36 months from purchase, parts and labour, provided it has been
More informationVSCOM USB PRO Series Industrial I/O Adapters
VSCOM USB PRO Series Industrial I/O Adapters 1.Introduction The VSCOM USB PRO Series Industrial I/O Adapters are advanced USB to Serial Adapters that connect to 1, 2, 4 or 8 RS-232/422/485 serial devices.
More information16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide
16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide 1. Introduction Thank you for purchasing this 16-Port RS232 to USB2.0 High Speed Multi Serial Adapter. It is an
More informationmaxon motor maxon motor control EPOS Positioning Controller Cable Starting Set Edition June 2006 part number 302287 Positioning Controller
control EPOS Positioning Controller Cable Starting Set Edition June 2006 24/1 part number 302287 Positioning Controller Documentation Cable Starting Set 1 Table of contents 1 Table of contents... 2 2 Table
More information2-Port RS232/422/485 Combo Serial PCI Card
2-Port RS232/422/485 Combo Serial PCI Card Installation Guide 1. Introduction Thank you for purchasing this 2-Port RS232/422/485 Combo Serial PCI Card. It is a universal add in card that connects to a
More informationCable Guide For all PortServer TS, Digi Connect, and Digi One Products
Cable Guide For all PortServer TS, Digi Connect, and Digi One Products 90000253_F Digi International Inc. 2011. Digi, Digi International, the Digi logo, Digi One, Digi Connect, PortServer TS, and RealPort
More informationISHIDA BC-3000. Scale to Scale Communications
ISHIDA BC-3000 Scale to Scale Communications Setup Procedure & Operating Instructions March 2006 PN 94561 Revision History Date Page Description March 2006 Initial publication August 2006 2 Added RS-232
More informationM-Bus Network Installation Notes
M-Bus Network Installation Notes 1 M-Bus Network Installation Notes This manual explains how to calculate the maximum M-Bus cable length depends on technical parameters of used cable and number of M-Bus
More informationCable Guide For all PortServer TS, Digi Connect, and Digi One Products
Cable Guide For all PortServer TS, Digi Connect, and Digi One Products 90000253_G Digi International Inc. 2013. Digi, Digi International, the Digi logo, Digi One, Digi Connect, PortServer TS, and RealPort
More informationMaking a DB to RJ45 adapter.
Making a DB to RJ45 adapter. DB9 to RJ45 adapters are often used in combination with a RS232 repeater for extending the distance of a serial RS232 link, but can be used for any adapter or converter purposes.
More informationAdvanced Data Capture and Control Systems
Advanced Data Capture and Control Systems Tronisoft Limited Email: sales@tronisoft.com Web: www.tronisoft.com RS232 To 3.3V TTL User Guide RS232 to 3.3V TTL Signal Converter Modules P/N: 9651 Document
More informationCabling Guide for Console and AUX Ports
Cabling Guide for Console and AUX Ports Contents Introduction Prerequisites Requirements Components Used Conventions Table of Routers with Console and AUX Ports Console Port Settings for Terminal Connection
More informationPCS0100en 02.2008. Persy Control Services B.V. Netherlands
P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for
More informationATS Communication Overview
ATS Communication Overview Viewpoint ATS 485 Communication link IBM Compatible Slide 1 of 23 Contents 1. Introduction 2. LonWork 3. Modbus Cards 4. Modbus Factory Configuration 5. Modbus Test Software
More informationMechoNet TM Network Interface (MNI) Specification Submittal
MechoNet TM Network Interface (MNI) Specification Submittal Models MechoNet Network Interface: MNI RJ (RJ45 Motor Ports): Stock No.: IMNI 0001 TP AS (US version) Stock No.: IMNI 0004 TP AS (UK version)
More informationFrame Relay Cabling This section describes the cabling and connector pinouts for the Frame Relay cards.
A P P E N D I B Cabling Summary Introduction This appendix contains details on the MG 8850 cabling. Note In all cable references, the transmit direction is away from the switch, and the receive direction
More informationIMACS. Cable and Equipment Guide. Premisys Communications. Integrated Multiple Access Communications Server. Publication 000-001903 Revision A2
IMACS Integrated Multiple Access Communications Server Cable and Equipment Guide Premisys Communications Publication 000-001903 Revision A2 February 1999 Trademarks: Premisys is a registered trademark
More informationModule Connectors and Cable Specifications
Module Connectors, page 1 Cables and Adapters, page 2 Cleaning the Fiber-Optic Connectors, page 6 Module Connectors RJ-45 Connector The RJ-45 connector is used to connect a Category 3, Category 5, Category
More informationApplication Note 83 Fundamentals of RS 232 Serial Communications
Application Note 83 Fundamentals of Serial Communications Due to it s relative simplicity and low hardware overhead (as compared to parallel interfacing), serial communications is used extensively within
More informationNOTE: It is the responsibility of the installation organization to have only technically qualified personnel performing the installation.
This quick start guide provides, basic installation information, drawings, first time power-on instructions, and short descriptions of key terms and concepts for installing the EntraGuard Platinum Telephone
More informationConnector and Cable Specifications
APPENDIX B This appendix provides the following cabling and pinout information for the Cisco IAD1101 integrated access device: Console Port Signals and Pinouts Ethernet Connector Pinouts Analog Subscriber
More informationModel 201 Wiegand Touchpad Reader Installation Guide
Model 201 Wiegand Touchpad Reader Installation Guide P/N 460353001C 15AUG11 2011 UTC Fire & Security. All rights reserved. This document may not be copied in whole or in part or otherwise reproduced without
More informationModbus Communications for PanelView Terminals
User Guide Modbus Communications for PanelView Terminals Introduction This document describes how to connect and configure communications for the Modbus versions of the PanelView terminals. This document
More informationWxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address
Instructions Page 1 Connections The WxGoos-1 is a self-contained web server and requires 6vdc of power at 300ma. A center-positive 2.1 mm plug is used. There are five ports: 1. 10/100 Ethernet RJ-45 receptacle
More informationElettronica dei Sistemi Digitali Costantino Giaconia SERIAL I/O COMMON PROTOCOLS
SERIAL I/O COMMON PROTOCOLS RS-232 Fundamentals What is RS-232 RS-232 is a popular communications interface for connecting modems and data acquisition devices (i.e. GPS receivers, electronic balances,
More informationEasySYNC Ltd. USB to Serial Converters Manual
EasySYNC Ltd Document Reference No.: ES_000061 Issue Date: 2011-08-23 The ES-U-xxxx-x adapters are a series of USB Serial Converters from EasySYNC Ltd. They provide a simple method of adapting legacy RS-232
More informationAPPLICATION NOTE. Leased Line Modem. Leased Line Modem...3. Introduction... 3. Key Concepts... 4
Issue Date 02/18/02 APPLICATION NOTE Leased Line Modem Leased Line Modem...3 troduction... 3 Key Concepts... 4 Application Details...4 Theory of Operation...6 Components...8 Planning Considerations...10
More informationRevision Date: September 19, 2006
RS232 to TTL Cables Revision Date: September 19, 2006 SuperDroid Robots Inc. is incorporated in Wake County, NC USA SuperDroid Robots also does business as Team Half-Life SuperDroid Robots is a registered
More informationUsing Xbee 802.15.4 in Serial Communication
Using Xbee 802.15.4 in Serial Communication Jason Grimes April 2, 2010 Abstract Instances where wireless serial communication is required to connect devices, Xbee RF modules are effective in linking Universal
More informationRS-232/422/485, Power over Ethernet
IP-COM-M IP-COMi-M IP-COM-M PoE IP-COMi-M PoE RS-232 RS-232/422/485 RS-232, Power over Ethernet RS-232/422/485, Power over Ethernet Edition: September 2012 The computer programs provided with the hardware
More informations!nus-elektrotechnikai bt. Industrial IT & Automation
USB/PPI+ Optoelectronic isolated USB/PPI adapter Optoelectronic isolated USB/PPI adapter, can replace Siemens 6ES7 901-3DB30-0XA0, the largest communication distance of up to 2 kilometers. Not support
More informationRS-422 and RS-485 Application Note
RS-422 and RS-485 Application Note International Headquarters B&B Electronics Mfg. Co. Inc. 707 Dayton Road -- P.O. Box 1040 -- Ottawa, IL 61350 USA Phone (815) 433-5100 -- General Fax (815) 433-5105 Home
More informationRS485 & RS422 Basics
RUA ALVARO CHAVES, 155 PORTO ALEGRE RS BRASIL 90220-040 TEL: +55 (51) 3323 3600 FAX: +55 (51) 3323 3644 info@novus.com.br RS485 & RS422 Basics INTRODUCTION The 422 and 485 standards, as they are known
More information2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide
2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide 1. Introduction Thank you for purchasing this 2-Port RS232/422/485 Combo Serial to USB Adapter.
More informationSmartio C168H/PCI User s Manual
Smartio C168H/PCI User s Manual Smartio 8 Ports Serial Board for PCI Bus Jul. 1999 (2nd Edition) The content of this manual is also available in CD-ROM and at Moxa Web Site. Moxa Technologies Co., Ltd.
More informationRS232 Data Interface a Tutorial on Data Interface and cables
RS232 Data Interface a Tutorial on Data Interface and cables From arc@arcelect.com RS-232 is simple, universal, well understood and supported but it has some serious shortcomings as a data interface. The
More informationG.703 Fractional T1 Access Unit. User Guide
G.703 Fractional T1 Access Unit User Guide Description The G.703 T1/FT1 ACCESS UNIT is a single port access unit for T1 or Fractional T1 services. Data Port rates are selectable via DIP-switches, for
More informationMassachusetts Institute of Technology Department of Electrical Engineering and Computer Science 6.115 Microprocessor Project Laboratory
Massachusetts Institute of Technology Department of Electrical Engineering and Computer Science 6.115 Microprocessor Project Laboratory Connecting your PSoC Evaluation Board It is easy and fun to avoid
More informationTIMING SIGNALS, IRIG-B AND PULSES
TIMING SIGNALS, IRIG-B AND PULSES Document No. PD0043200B July 2013 Arbiter Systems, Inc. 1324 Vendels Circle, Suite 121 Paso Robles, CA 93446 U.S.A. (805) 237-3831, (800) 321-3831 http://www.arbiter.com
More informationRJ11 RS-232 Interface
H NS TN30 RJ11 RS-232 Interface 1.0 General The back panel of the CPP-3794 provides a combination of 9 pin DB connectors and RJ11 connectors for connecting RS-232 serial cables. The 9 pin DB connector
More informationKOM200. Industrial Serial to Fiber Media Converter. User s Manual
KOM200 s Manual 200911 KOM200 Industrial Serial to Fiber Media Converter s Manual KYLAND Technology Co., Ltd. 1 KOM200 s Manual 200911 Table of contents CHAPTER 1: PRODUCT OVERVIEW---------------- 3 CHAPTER
More informationUsing installed Fieldbus Wiring to carry Ethernet Communications
Using installed Fieldbus Wiring to carry Ethernet Communications Modbus Plus, Data Highway, GE Genius, Profibus, ControlNet, DeviceNet, InterbusS and many other RS232 or RS4422 cables Key Issues when upgrading
More informations!nus-elektrotechnikai bt. Industrial IT & Automation
USER MANUAL s!nus-elektrotechnikai bt. USB/PPIM+ Siemens S7-200 USB/PPI Multi-Master Cable USB/RS485 Isolated For all PPI-Bus System Summary: USB / PPIM + is the PPI Multi-Master programming Cable which
More informationPmod peripheral modules are powered by the host via the interface s power and ground pins.
Digilent Pmod Interface Specification Revision: November 20, 2011 1300 NE Henley Court, Suite 3 Pullman, WA 99163 (509) 334 6306 Voice (509) 334 6300 Fax Introduction The Digilent Pmod interface is used
More informationBluetooth UART/RS232 Module
Introduction BLUEMORE600 is a professional, slim, wireless module ready for integration in brand new or existing electronic products. Based on CSR chipset BC03MM it s fully compatible for Serial Port profiles.
More informationOne Port Serial Server Users Manual Model ESP901, ESP901E
One Port Serial Server Users Manual Model ESP901, ESP901E Documentation Number: ESP901-2303 International Headquarters B&B Electronics Mfg. Co. Inc. 707 Dayton Road -- P.O. Box 1040 -- Ottawa, IL 61350
More informationProgramming and Using the Courier V.Everything Modem for Remote Operation of DDF6000
Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000 1.0 Introduction A Technical Application Note from Doppler System July 5, 1999 Version 3.x of the DDF6000, running version
More informationUser Manual IC-485AI 2002-09-27
User Manual IC-485AI Note: This equipment has been tested and found to comply ith the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
More informationNPort DE-311 Hardware Installation Guide
NPort DE-311 Hardware Installation Guide Fourth Edition, June 2008 www.moxa.com/product 2008 Moxa Inc., all rights reserved. Reproduction without permission is prohibited. NPort DE-311 Hardware Installation
More informationGold Eagle HV Gold Eagle HV Cable Kit (EtherCAT and CAN)
Gold Eagle HV Gold Eagle HV Cable Kit (EtherCAT and CAN) January 2014 (Ver. 1.000) Notice This guide is delivered subject to the following conditions and restrictions: This guide contains proprietary information
More informationSyncLink GT2/GT4 Serial Adapter
SyncLink GT2/GT4 Serial Adapter Hardware User s Manual MicroGate Systems, Ltd http://www.microgate.com MicroGate and SyncLink are registered trademarks of MicroGate Systems, Ltd. Copyright 2008 2012 MicroGate
More informationPower Supply and Cabling Options. SmartTrak 100/101/140
Power Supply and Cabling Options SmartTrak 00/0/40 2 Power Supply and Cabling Options SmartTrak 00/0/40 Table of Contents Power Supplies... Communication Cables... Accessory Options... Appendix A Communication
More informationRS-485 the Murphy Way!
RS-485 the Murphy Way! Proper Use of Murphy s RS-485 Ports. Murphy Switch of California, Inc. has chosen to support two methods of differential communications. One method is fail-safe biasing of the RS-485
More informationIMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions
IMMS-CCC IMMS-CCC Hardwire Central Interface Installation Instructions TABLE OF CONTENTS... Choose a Location... 1 Connections... 2 Operations... 3 Software Configuration... 4 Troubleshooting... 5 Loopback
More information400 Series - Mini USB Buccaneer
IP68 Sealed IP68 rated USB V2.0 performance Plug and play capability Shielded system Overmoulded cables Screw coupling PCB versions Dust and waterproof to EN60529 Data rates up to 480Mbs Hot pluggable,
More informationMFRD52x. Mifare Contactless Smart Card Reader Reference Design. Document information
Rev. 2.1 17. April 2007 Preliminary Data Sheet Document information Info Keywords Content MFRC522, MFRC523, MFRC52x, MFRD522, MFRD523, Mifare Contactless Smart Card Reader Reference Design, Mifare Reader
More informationWhen any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Samba OPLC SM35-J-R20 Installation Guide The Unitronics SM35-J-R20 offers the following onboard I/Os: 12 Digital Inputs, configurable via wiring to include: 1 HSC/Shaft-encoder Input, 2 Analog inputs (only
More informationCIN::APSE MICROMINIATURE D-SUB
INTRODUCTION CINCH has been producing filter connectors for years and has acquired an in depth knowledge of EMC protection. CINCH offers fast delivery on a wide range of standard filtered connectors and
More informationCabling Specifications
APPENDIX A This appendix provides cabling and pinout information for feature cards on the Cisco AS5350XM and Cisco AS5400XM universal gateways. It contains the following sections: 2-Port and 4-Port T1
More informationTelebyte 209 Short Haul Modem
Telebyte 209 This document provides installation instructions for the Telebyte 209 (Keri Systems P/N SHM-232). This short haul modem can be used to assist in long-distance, direct, connections between
More informationLocoNet, the Digitrax Difference
LocoNet, the Digitrax Difference LocoNet is Digitrax's method of communication between LocoNet compatible devices on a model railroad layout. LocoNet Compatible devices are designed to work together on
More informationTable of Contents. Creating a VC1000 Network... 3
2 Table of Contents Creating a VC1000 Network... 3 Topology... 3 Unit ddressing... 4 Terminating Resistors... 5 Shielding... 5 Interconnecting the common... 6 ias Resistors... 6 VC1000 Hardware Configuration...
More informationINSTALLATION and OPERATION MANUAL
INSTALLATION and OPERATION MANUAL Table of Contents Chapter 1: Introduction 1.1 General. 1 1.2 Data Port Interfaces. 2 1.3 G.703/64K Interface 3 1.4 Features 6 1.5 Specifications... 6 1.6 Loop Back Diagnostics
More informationRS-422/485 Multiport Serial PCI Card. RS-422/485 Multiport Serial PCI Card Installation Guide
RS-422/485 Multiport Serial PCI Card Installation Guide 21 Contents 1. Introduction...1 2. Package Check List...2 3. Board Layouts and Connectors...3 3.1 2S with DB9 Male Connectors...3 3.1.1 JP5: UART
More informationHARDWARE MANUAL. BrightSign HD120, HD220, HD1020. BrightSign, LLC. 16795 Lark Ave., Suite 200 Los Gatos, CA 95032 408-852-9263 www.brightsign.
HARDWARE MANUAL BrightSign HD120, HD220, HD1020 BrightSign, LLC. 16795 Lark Ave., Suite 200 Los Gatos, CA 95032 408-852-9263 www.brightsign.biz TABLE OF CONTENTS OVERVIEW... 1 Block Diagram... 2 Ports...
More informationRC2200DK Demonstration Kit User Manual
Demonstration Kit User Manual Table of contents TABLE OF CONTENTS... 1 QUICK INTRODUCTION... 2 INTRODUCTION... 3 DEMONSTRATION BOARD... 4 POWER SUPPLY SECTION... 5 RS-232 INTERFACE... 6 CONNECTORS... 7
More informationAppendix A. This Appendix includes the following supplemental material:
Appendix A This Appendix includes the following supplemental material: Cabling Diagrams and Instructions Connectors (9-pin D-type) Data Transfer Protocols Usage/Handshaking Ultimax Dual Screen Console
More informationUSB to RS-422/485 Serial Adapter
USB to RS-422/485 Serial Adapter User Manual Ver. 2.00 All brand names and trademarks are properties of their respective owners. Contents: Chapter 1: Introduction... 3 1.1 Product Introduction... 3 1.2
More information485USBTB-2W & 485USBTB-4W
RS-485 2-Wire RS-485 4-Wire Connector Data Rate Connector Standard Data Rate Source Input Voltage Consumption Driver CD Dimensions Enclosure Weight Operating Temp Storage Temp Op Humidity MTBF MTBF Method
More informationEDI Distributor Control Interface Wiring and Setup Instructions
Universal I/O EDI Distributor Control Interface Wiring and Setup Instructions EDI UNIVERSAL I/O INTERFACE MODULE The only interface needed for EDI-V5 controls Network compatible with all older EDI controls
More informationIMVIB. Online vibration monitoring for Ariel compressors
IMVIB Online vibration monitoring for Ariel compressors The cost-effective way to add spectral vibration measurement & trending on critical machinery Monitoring vibration trends of your industrial equipment
More informationOmron I/O Driver (Series 2) Programmable Serial Interface Card
Omron I/O Driver (Series 2) Programmable Serial Interface Card USER MANUAL Rev. P1.55 June 8, 2012 DeltaV is a trademark of Emerson Process Management, Inc Emerson Process Management, Inc. 1998, 1999.
More informationEncore Controller to Router Connections
Encore Presentation System Encore Controller to Router Connections Contents: Scope... 2 EXT COMM Pinouts... 2 Cable Connection Straight Through... 3 Cable Connection Null Modem... 3 Lantronix Ethernet
More informationROLINE THE Difference
ROLINE THE Difference The products of the brand ROLINE are developed for professional users and differ in their quality substantially from comparable products in the IT environment. The high compatibility
More information