1 INSTALLATION and OPERATION MANUAL
2
3 Table of Contents Chapter 1: Introduction 1.1 General Data Port Interfaces G.703/64K Interface Features Specifications Loop Back Diagnostics Timing Considerations. 7 Chapter 2: Installation and Operation 2.1 General Site Preparation Mechanical Assembly Electrical Installation Dip Switch and Jumper Settings Front Panel Loop Back Operation Auto Delay Feature.. 16 Chapter 3: Optional Rack Mounting Appendix A: DIP Switch Setting Tables A.1 DSW1 Setting (Clock Source Setup).. 19 A.2 DSW2 Setting (Data Port Setup) 20 A.3 DSW3 Setting (Delay Setup).. 21 i
4 Table of Contents Appendix B: Cable Pin Out Definition Tables. 23 B.1 DB9 Connectors.. 23 B.2 User Data Port Connector for RS B.3 User Data Port Connector for RS B.4 User Data Port Connector for V B.5 User Data Port Connector for X B.6 User Data Port Connector for RS B.7 User Data Port Connector for V ii
5 Chapter 1: Introduction 1.1 General The Access Unit is used to multiplex two G.703/64Kbps bit flows to one 128K Synchronous Data Port or vice versa. Referring to the Point-to-Point example below, no additional bandwidth is available for synchronization. Therefore, it is important that the transmission delay between the two units be less than half of a 64Kbps cycle. Figure 1-1: Point to point connection diagram The delay between A CH 64K and B CH 64K should be the same. Any delay may be manually nulled via DIP switch settings. The delay may also be automatically detected while in Auto Delay mode for automatic nulling. In either case, for normal operation, the delay between channels must remain fixed after setting. 128Kbps data A CH 64Kbps B CH 64Kbps Figure 1-2: Multiplex/De-multiplex Timing Diagram 1
6 Chapter 1: Introduction To achieve proper operation, the timeslot assignment of transmit and receive sides must be the same and sequential, otherwise, the multiplex and de-multiplex feature will not work reliably. Figure 1-3: Typical Application of 1.2 Data Port Interfaces The data port of the is DCE and runs at a fixed rate of 128Kbps in synchronous mode only. At the receiving side, the incoming data is split equally, bit-for-bit, to the A and B channels of the G.703/64K interfaces. When receiving data from the G.703 channels, the data is recombined to form the outputted 128Kbps stream. There are 6 interface standards supported by the Data Port. They are RS-530, RS-449, X.21, V.35, RS-232 and V.36. The output connector for the Data Port is a standard DB25F connector. Interface selection is provided by a combination of DIP switch settings and physical adapter cables. For exact DIP switch settings and cabling information, please refer to Appendices A and B respectively. 2
7 Chapter 1: Introduction 1.3 G.703/64K Interface The G.703 Interfaces used in the have a through rate of 64Kbps each and operate in co-directional mode only. The following will describe co-directional operation in more detail. Co-directional The term co-directional is used to describe an interface across which the information and its associated timing signal are transmitted in the same direction (see Figure 1-4). Equipment Equipment Data signal Timing signal Figure 1-4: Co-directional interface This mode is the most popular for point-to-point applications. All timing modes (recovery, transparent, data port or internal oscillator) are possible in this mode. 3
8 Chapter 1: Introduction G.703 Co-directional Code Conversion Rules Bit number kbit/s data Steps 1-3 Step 4 Step 5 Violation Violation Octet timing Figure 1-5: G.703 Co-directional Code Conversion Rules Illustration Step 1: A 64Kbps period is divided into four unit intervals. Step 2: A binary one is coded as a block of four bits Step 3: A binary zero is coded as a block of four bits Step 4: The binary signal is converted into a three-level signal. Step 5: A Violation block marks the last bit in an octet. The next page displays a figure showing the boundaries for the standard pulse signals for proper operation and compatibility with other G.703 equipment. 4
9 Chapter 1: Introduction V 1,0 0,5 3,12 µs (3,9 0,78) 3,51 s (3,9 0,39) 3,9 µ s 0 4,29 µs (3,9 + 0,39) 6,5 µs (3,9 + 2,6) 7,8 µ s (3,9 + 3,9) a)mask for single pulse V 1,0 0,5 7,02 µs (7,8 0,78) 7,41 µs (7,8 0,39) 7,8 s 0 8,19 µs (7,8 + 0,39) 10,4 µs (7,8 + 2,6) 11,7 s (7,8 + 3,9) b)mask for double pulse Figure 1-6: Pulse Masks for the 64Kbps co-directional interface. 5
10 Chapter 1: Introduction 1.4 Features Primary G.703 Link 2 channels (2x64Kbps) Interface: 64Kbps G.703 co-directional Synchronous mode Data Port interface 1 channel DCE-128Kbps: RS-530, RS-449, X.21, V.35, RS-232, or V.36 Data Port DSR constantly ON except in test DCD constantly ON Data port Loop back (Loop back to DTE) Self testing function 1-5 Specifications G.703 Interface Specifications Type: Co-directional 64Kbps Line: 4 wires 0.5~0.7mm Impedance: 120 Ω (Balanced) Clock frequency: 64KHz ±100ppm Complies with: ITU G.703 and G.823 (jitter) Frame format: unframed only Line code: 64Kbps co-directional line code Connector: DB9/F (proprietary) User Data Interface Specifications Interface Types: RS530, RS-449, X.21, V.35, RS-232 and V.36 Data rate: 128Kbps SYNC Connector: DB25/F plus adapter cables 6
11 Chapter 1: Introduction 1.6 Loop back Diagnostics The features V.54 diagnostic capabilities for performing local loopback and BERT testing. The operator at either end of the G.703 lines may test the in the digital loopback mode. The loopback function is controlled by push-button switches, located on the front panel. When the Test push-button is activated, the unit generates a 511 test pattern, according to ITU, for direct endto-end integrity testing. The Error indicator flashes for each bit error detected. Operation is described in Chapter Timing Considerations Multiple clock source selection provides maximum flexibility in connecting both the G.703/64K link and user data interface. The G.703/64K link may be clocked from the recovered receive clock, from the user data port or from the internal oscillator. The has the flexibility to meet the timing requirements of various system configurations. The timing mode for the G.703/64K link and the user channel, is selected by DIP switch setting. 7
12 Chapter 1: Introduction E1 link timing The G.703/64K link receive path always operates on the receive clock. The recovers the receive clock from the received link data signal. The source of the link transmit clock may be selected by the user. The following four transmit timing modes are available. Recovery timing: The G.703 link transmit clock is locked to the recovered receive clock. This is usually the timing mode selected for network operation. Internal timing: The G.703 link transmit clock is derived from the internal clock oscillator. This timing mode is necessary in point-to-point applications over leased lines. In this case, one must use the internal oscillator, and the other must operate from the recovered clock. Transparent timing: The synchronous data channel accepts the recovered G.703 clock and provides the G.703 transmit clock from the DCE (Transparent timing). External timing: The ETU-01A E1 link transmit clock is locked to the clock signal provided by the user DCE connected to the data channel. 8
13 Chapter 2: Installation and Operation 2.1 General This chapter provides detailed instructions for mechanical installation and operation of the. 2.2 Site Preparation Install the within reach of an easily accessible grounded AC outlet. The outlet should be capable of furnishing 90 ~ 250 VAC. Allow at least 10 cm (4 inch) clearance at the rear of the for signal lines and interface cables. 2.3 Mechanical Assembly The is designed for tabletop, bench, or optional rack mount installation, and is delivered completely assembled. No provision has been made for bolting the to a tabletop. Rack mounting instructions are provided in Chapter Electrical Installation Power connection AC power is supplied to the through a standard 3-prong IEC connector. (Refer to Figure 2-1) The should always be grounded through the protective earth lead of the power cable. The power supply within the is a switching power type, designed to operate from any AC voltage, 90 to 250 volts. 9
14 Chapter 2: Installation and Operation IEC Connector and fuse holder Data Port Connector G.703/64K Connectors Figure 2-1: back panel The line fuse is located in an integral-type fuse holder on the rear panel. Make sure that only fuses of the required rating are used for replacement. Do not use repaired fuses or shortcircuit the fuse holder. Always disconnect the power cable before removing or replacing the fuse Rear panel connectors The s CH-128 DB25F connector, in combination with various DIP switch settings and adapter cables, provides for six interface types (RS-530, RS-449, X.21, V.35, RS-232 and V.36). The G.703/64K line connectors incorporate DB9F connectors. (Appendix B provides detailed pin out information on the various interface connectors). 10
15 Chapter 2: Installation and Operation 2.5 DIP Switches and Jumper Settings Caution To avoid accidental electrical shock, disconnect the power cord prior to opening the cover Procedure a. Turn power OFF. Disconnect the power cord from the AC outlet. b. Loosen the thumb screws at the left/right of the rear panel. c. Remove the PCB assembly. d. Adjust the DIP switches and jumper as required, according to the tables in Appendix A. e. Replace the PCB and tighten the screws. Referring to the following figure, three DIP switches are used for configuration and are labeled DSW1 to DSW3. If a DIP switch configuration is changed while the is in a powered on state, the effect will not be realized until the unit is power cycled off then on. The Logic Ground Jumper will connect (CON) or disconnect (DIS) the logic ground from chassis ground. Chassis ground is connected directly to the ground post of the IEC power connector. 11
16 Chapter 2: Installation and Operation G.703/64K (x2) CH-128 Data Port DSW1 DSW2 DSW3 Logic Ground Jumper Indicator LEDs Loop Back Test Sws. Figure 2-2: Printed Circuit Board Diagram 12
17 Chapter 2: Installation and Operation 2.6 Front Panel The front panel of the provides user access to the diagnostic loop back push-button switches as well as a visual reference of activity via LED display. Figure 2-3: front panel layout Label Color Description PWR green Lights when unit is powered on. TD yellow Flashes when data is transmitted from the 128K data port. RD yellow Flashes when data is received at the 128K data port. RTS yellow Lights when the connected DTE equipment supplies RTS. DCD yellow Normally, should be lit during operation. Ta yellow Flashes when G.703 A-channel transmits data. Ra yellow Flashes when G.703 A-channel receives data. Tb yellow Flashes when G.703 B-channel transmits data. Rb yellow Flashes when G.703 B-channel receives data. Err red Indicates error in BERT or slip in A-B channel delay. Test red Lights when any push-button switch is selected. 2.7 Loop Back Operation Table 2-1: Indicator LED descriptions The loop back test buttons and LED indicators built into the allow for rapid checking of the data terminal, and the G.703/64K lines. Before testing the operation of the data system equipment and line circuits, please ensure that all units are turned on and are configured correctly. 13
18 Chapter 2: Installation and Operation Bit Error Rate Tester When the Test push-button is depressed, the internal pattern generator and pattern tester will be activated and a 511 test pattern will be transmitted out the 64K co-directional lines. The Test LED will light. Referring to figure 2-4, if the remote unit also has its Test push-button switch depressed, its internal pattern generator and tester will be activated and its signal will be received by the local unit. In this configuration, both units and the lines are tested. Both units will have their Test LEDs lit and Err LEDs should be off. Figure 2-4: Back-to-back BERT testing Referring to figure 2-5, if the remote unit is placed into loop back by placing its Loc ana loopbk switch in the depressed position, the 511 pattern will be returned to the local unit and tested. This will test the local unit and lines. If there are no errors, the Err LEDs should be off. 14
19 Chapter 2: Installation and Operation Figure 2-5: Remote loop back test In the next example (refer to figure 2-6), a Datacom BERT tester, such as the HCT-6000 is connected to the data port. The is placed in DTE loop back mode by depressing the "DTE loopbk pushbutton switch. This will enable testing of the data port interface. Figure 2-6: Data Port BERT 15
20 Chapter 2: Installation and Operation 2.8 Auto Delay A feature of the is the auto delay function. If the two G.703/64K Co-directional signals arrive out of time at the receivers, the 128K data stream cannot be properly reassembled. The delay between channels may be nulled by manually setting DIP switch 3 or by performing the auto delay function. In order to perform auto delay, there must be someone at each end of the link (refer to figure 2-7). Figure 2-7: Null Delay Feature At the local and remote sites, depress the Test switches. Then depress the Auto Delay switches on each unit. When the Err LEDs go out, release the Auto Delay switches. The delay both ways has been calculated and saved in each unit. Now release the Test switches. The delay settings have been saved in EEPROM and are read whenever the unit is powered up. There is no need to re-calibrate unless the environment is changed. 16
21 Chapter 3: Optional Rack Mounting All Standalone/Rack Series units have the option of adding standard EIA 19 rack mount capability. Two rack mount options provide for either mounting a single unit (half space) in a rack or for mounting two units in tandem (full space). In either situation, one standard rack unit space is required. Each rack mount kit provides all the necessary hardware for a complete installation. Figure 3-1: Rack Mount Installation, ETU01-SS. In single unit installations, the unit may be placed in the left or right side position simply by reversing the rack mounting ears. The kit includes, one (1) short and one (1) long rack adapter, four (4) 3x8mm self-tapping screws, and four (4) #12-24x0.5 screws. 17
22 Chapter 3: Optional Rack Mounting In order to save rack mount space, units may be mounted in tandem. Please refer to the following drawing examples for this application. Figure 3-2: Tandem Units Mounting (Exploded) Figure 3-3: Tandem Units Mounting Detail The tandem kit includes two (2) rack mount adapters, one (1) each of inner and outer central mounting adapters, twenty (20) 3x8mm self-tapping screws, and four (4) #12-24x0.5 screws. 18
23 Appendix A: DIP Switch Setting Tables A.1 DSW1 Setting (Clock Source Setup) DSW1 STATE FUNCTION OFF OFF RX timing from recovery, TX timing from data -1-2 port. ON OFF RX and TX timing both from recovery. OFF ON RX and TX timing both from data port. ON ON RX and TX timing both from internal oscillator.* -3 OFF Recovery timing source: Channel A.* ON Recovery timing source: Channel B. -4 Reserved. -5 Reserved. -6 Reserved. -7 Reserved. -8 Reserved. * note: Factory setting. 19
24 Appendix A: DIP Switch Setting Tables A.2 DSW2 Setting (Data Port Setup) DSW2 STATE FUNCTION OFF OFF Data port type: RS-530, RS-449, X.21* -1-2 ON OFF Data port type: V.35 OFF ON Data port type: RS-232 (SYNC ONLY) ON ON Data port type: V.36-3 OFF RX clock polarity: NORMAL* ON RX clock polarity: INVERTED -4 OFF TX clock polarity: NORMAL* ON TX clock polarity: INVERTED -5 OFF CTS: Always ON* ON CTS: Follow RTS -6 OFF Reserved. ON Reserved. -7 OFF Reserved. ON Reserved. -8 OFF Front panel switches: DISABLE ON Front panel switches: ENABLE* *note: Factory setting. 20
25 Appendix A: DIP Switch Setting Tables A-3 DSW3 Setting (Delay) DSW2 STATE FUNCTION OFF OFF OFF OFF OFF Delay clock cycle: 0 ON OFF OFF OFF OFF Delay clock cycle: 1 OFF ON OFF OFF OFF Delay clock cycle: 2 ON ON OFF OFF OFF Delay clock cycle: 3 OFF OFF ON OFF OFF Delay clock cycle: 4 ON OFF ON OFF OFF Delay clock cycle: 5 OFF ON ON OFF OFF Delay clock cycle: 6 ON ON ON OFF OFF Delay clock cycle: 7 OFF OFF OFF ON OFF Delay clock cycle: 8 ON OFF OFF ON OFF Delay clock cycle: 9 OFF ON OFF ON OFF Delay clock cycle: 10 ON ON OFF ON OFF Delay clock cycle: 11 OFF OFF ON ON OFF Delay clock cycle: 12 ON OFF ON ON OFF Delay clock cycle: 13 OFF ON ON ON OFF Delay clock cycle: 14 ON ON ON ON OFF Delay clock cycle: 15 OFF OFF OFF OFF ON Delay clock cycle: 16 ON OFF OFF OFF ON Delay clock cycle: 17 OFF ON OFF OFF ON Delay clock cycle: 18 ON ON OFF OFF ON Delay clock cycle: 19 OFF OFF ON OFF ON Delay clock cycle: 20 ON OFF ON OFF ON Delay clock cycle: 21 OFF ON ON OFF ON Delay clock cycle: 22 ON ON ON OFF ON Delay clock cycle: 23 OFF OFF OFF ON ON Delay clock cycle: 24 ON OFF OFF ON ON Delay clock cycle: 25 OFF ON OFF ON ON Delay clock cycle: 26 ON ON OFF ON ON Delay clock cycle: 27 OFF OFF ON ON ON Delay clock cycle: 28 ON OFF ON ON ON Delay clock cycle: 29 OFF ON ON ON ON Delay clock cycle: 30 ON ON ON ON ON Delay clock cycle: 31-6 OFF Delay channel: B ON Delay channel: A -7 Reserved. -8 Reserved. 21
26 Appendix A: DIP Switch Setting Tables This page left blank intentionally. 22
27 Appendix B: Cable Pinout Definition Tables B.1 DB9 Connectors The analog port physical interface is a 9- pin female D-type connector wired in accordance with Table B-1. Pin Designation Direction Function 1 TTIP From Transmit data (+) RTIP To Receive data (+) FG Frame ground 6 TRING From Transmit data (-) RRING To Receive data (-) Table B-1: DB-9 connector pin allocation 23
28 Appendix B: Cable Pinout Definition Tables B.2 User DATA Port Connector For RS-232 The user data channel for RS-232 physical interface is a 25-pin female D-type connector wired in accordance with Table B-2. Abbr. Pin Direction Description FG 1 Chassis ground. May be isolated from signal ground. SG 7 Signal Ground. TD 2 To Serial digital data from DTE. RD 3 From Serial digital data at the output of the /2*64K receiver. RTS 4 To CTS 5 From DSR 6 From DTR 20 To DCD 8 From ETC 24 To TC 15 From RC 17 From Supply an ON signal to the /2*64k when data transmission is desired. Constantly ON or follow RTS. (by DIP SW setting). Constantly ON, Except during test loops. Not used. Constantly ON. A transmitted data rate clock input from the data source. A transmitted data rate clock for use by an external data source. A received data rate clock for use by an external data source. Table B-2 RS-232 pin allocation 24
29 Appendix B: Cable Pinout Definition Tables B.3 User Data Port Connector For RS-530 The user data channel for RS-530 physical interface is a 25-pin female D-type connector wired in accordance with Table B-3. Abbr. Pin Direction Description FG 1 Chassis ground. May be isolated from signal ground. SG 7 Signal Ground. TD(A) 2 To Serial digital data from DTE. TD(B) 14 RD(A) RD(B) 3 16 From Serial digital data at the output of the /2*64K receiver. RTS(A) RTS(B) 4 19 To ON signal to the /2*64k when data transmission is desired. CTS(A) CTS(B) 5 13 From Constantly ON or follow RTS. (DIP SW setting). DSR(A) DSR(B) 6 22 From Constantly ON, Except during test loops. DTR(A) 20 To Not used. DTR(B) 23 DCD(A) 8 From Constantly ON. DCD(B) 10 ETC(A) ETC(B) To A transmitted data rate clock input from the data source. TC(A) TC(B) From A transmitted data rate clock for use by an external data source. RC(A) RC(B) 17 9 From A received data rate clock for use by an external data source. Table B-3: RS-530 pin allocation 25
30 Appendix B: Cable Pinout Definition Tables B.4 DB25 to MB34 Cable Pin Out for V.35 The user data channel for V.35 physical interface is a cable adapter with a 34-pin female MB-type connector wired in accordance with Table B-4. Abbr. DB25 PIN# MB34 PIN# V.35 Circuit FG 1 A Chassis ground. May be isolated from signal ground. SG 7 B Signal Ground TD(A) TD(B) 2 14 P S TD(A) TD(B) RD(A) RD(B) 3 16 R T RD(A) RD(B) RTS(A) 4 C RTS CTS(A) 5 D CTS DSR(A) 6 E DSR DTR(A) 20 H DTR DCD(A) 8 F DCD ETC(A) ETC(B) U W ETC(A) ETC(B) TC(A) TC(B) Y AA TC(A) TC(B) RC(A) RC(B) 17 9 V X RC(A) RC(B) Table B-4: DB25 to MB34 Cable Pin Out for V.35 26
31 Appendix B: Cable Pinout Definition Tables B.5 DB25 to DB15 Cable Pin Out for X.21 The user data channel for X.21 physical interface is a cable adapter with a 15-pin female DB-type connector wired in accordance with Table B-5. Abbr. DB25 PIN# DB15 PIN# X.21 Circuit FG 1 1 Chassis ground. May be isolated from signal ground. SG 7 8 Signal Ground TD(A) TD(B) Transmit(A) Transmit(B) RD(A) RD(B) Receive(A) Receive(B) RTS(A) RTS(B) Control(A) Control(B) DCD(A) DCD(B) Indication(A) Indication(B) ETC(A) ETC(B) External Timing(A) External Timing(B) RC(A) RC(B) Signal Timing(A) Signal Timing(B) Table B-5: DB25 to DB15 Cable Pin Out for X.21 27
32 Appendix B: Cable Pinout Definition Tables B.6 DB25 to DB37 Cable Pin Out for RS-449 The user data channel for RS-449 physical interface is a cable adapter with a 37-pin female DBtype connector wired in accordance with Table B-6. Abbr. DB25 PIN# DB37 PIN# RS-449 Circuit FG 1 1 Chassis ground. May be isolated from signal ground. SG 7 19,20,37 SG,RC,SC TD(A) TD(B) SD(A) SD(B) RD(A) RD(B) RD(A) RD(B) RTS(A) RTS(B) RS(A) RS(B) CTS(A) CTS(B) CS(A) CS(B) DSR(A) DSR(B) DM(A) DM(B) DTR(A) DTR(B) TR(A) TR(B) DCD(A) DCD(B) RR(A) RR(B) ETC(A) ETC(B) TT(A) TT(B) TC(A) TC(B) ST(A) ST(B) RC(A) RC(B) RT(A) RT(B) Table B-6: DB25 to DB37 Cable Pin Out for RS
33 Appendix B: Cable Pinout Definition Tables B.7 DB25 to DB37 Cable Pin Out for V.36 The user data channel for V.36 physical interface is a 25-pin female D-type connector wired in accordance with Table B-7. Abbr. Pin Direction Description FG 1 Chassis ground. May be isolated from signal ground. SG 7 Signal Ground. TD(A) 2 To Serial digital data from DTE. TD(B) 14 RD(A) RD(B) 3 16 From Serial digital data at the output of the /2*64K receiver. RTS 4 To ON signal to the /2*64k when data transmission is desired. CTS 5 From Constantly ON or follow RTS. (DIP SW setting). DSR 6 From Constantly ON, Except during test loops. DTR 20 To Not used. DCD 8 From Constantly ON. ETC(A) ETC(B) To A transmitted data rate clock input from the data source. TC(A) TC(B) From A transmitted data rate clock for use by an external data source. RC(A) RC(B) 17 9 From A received data rate clock for use by an external data source. Table B-7: User Data Port Connector Pin Out for V.36 29
34
35
36 CTC Union Technologies Co., Ltd. Far Eastern Vienna Building (Neihu Technology Park) 8F, No. 60 ZhouZi St. Neihu, Taipei, Taiwan Phone:(886) Fax:(886)
G.703 Fractional T1 Access Unit. User Guide
G.703 Fractional T1 Access Unit User Guide Description The G.703 T1/FT1 ACCESS UNIT is a single port access unit for T1 or Fractional T1 services. Data Port rates are selectable via DIP-switches, for
More informationBTM10 Series Transmission Analyzer
BTM10 Series Transmission Analyzer BTM10/E1 BTM10/T1 BTM10/E1/T1 E1 and T1 Telecom/Datacom Analyzer Portable Analyzer series Introduction The BTM10 series analyzers come in three firmware models that support
More informationIMACS. Cable and Equipment Guide. Premisys Communications. Integrated Multiple Access Communications Server. Publication 000-001903 Revision A2
IMACS Integrated Multiple Access Communications Server Cable and Equipment Guide Premisys Communications Publication 000-001903 Revision A2 February 1999 Trademarks: Premisys is a registered trademark
More informationFOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology
FOSTCDR pn 8684R1 FOSTCDR-0812ds page 1/5 Industrial Serial to Multimode Fiber Optic Converter Data Rates up to 115.2 kbps 2.5 Mile (4 km) Range 10 to 30 VDC Input Voltage Wide Operating Temperature 2000V
More informationChapter 4 T1 Interface Card
Chapter 4 T1 Interface Card GENERAL This chapter describes DTE interface options that may be required if application requirements change. It also describes software configuration for the T1 interface card.
More informationConfiguring Serial Interfaces for E1- and T1-Carrier Lines
5 Configuring Serial Interfaces for E1- and T1-Carrier Lines Contents Using the Serial Module for E1- or T1-Carrier Lines.................. 5-3 Elements of an E1- or T1-Carrier Line..........................
More informationUser Manual IC-485AI 2002-09-27
User Manual IC-485AI Note: This equipment has been tested and found to comply ith the limits for a Class A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
More informationFOM-5A, 6A. Asynchronous Fiber Optic Modem
FOM-5A, 6A Asynchronous Fiber Optic Modem FEATURES Asynchronous transmission at up to 19.2 kbps Transmission range up to 3 km (1.8 mi), regardless of data rate Full- or half-duplex Transfers one control
More informationF2400 FOM II Series Fiber Optic Modem Technical Manual
F2400 FOM II Series Fiber Optic Modem Technical Manual T1 Revision B Copyright April 2003 VERSITRON, Inc. 83 Albe Drive / Suite C Newark, DE 19702 www.versitron.com A030430283T PROPRIETARY DATA All data
More informationLOXONE 12 Channel Amplifier
LOXONE 12 Channel Amplifier Item no.: 200110 Thank you for purchasing the Loxone Twelve Channel Amplifier. The versatility of the Amplifier makes it the perfect choice for almost every type of custom multi-room
More informationIPG/7700 Hardware Manual SYSTECH. Document number 80-001099-7 Revision A
IPG/7700 Hardware Manual SYSTECH C O R P O R A T I O N Document number 80-001099-7 Revision A Created 2010, and Protected Under the U.S. Copyright Act of 1976. Copyright 2010, SYSTECH Corporation All Rights
More informationRS-232 COMMUNICATIONS
Technical Note D64 0815 RS-232 COMMUNICATIONS RS-232 is an Electronics Industries Association (EIA) standard designed to aid in connecting equipment together for serial communications. The standard specifies
More informationZC-24DO CANopen I/O Module: 24 Digital Outputs
Z-PC Line EN ZC-24DO CANopen I/O Module: 24 Digital Outputs Installation Manual Contents: - General Specifications - Technical Specifications - Installation Rules - Electrical connections - DIP-switches
More informationConnecting Serial Interface Cards to a Network
CHAPTER 3 This chapter describes how to connect Cisco serial interface cards to a network and contains the following sections: Serial WAN Interface Cards (WICs), page 3-1 Serial High Speed WICs (HWICs),
More informationFOMi-E3, FOMi-T3 E3, T3, and HSSI Manageable Fiber Optic Modems
Data Sheet FOMi-E3, FOMi-T3 Extend the range of E3, T3 or HSSI services over fiber optic cables up to 110 km (68 miles) Transparently transmit E3, T3 or HSSI signals over multimode and single-mode fiber
More informationFCD-E1E Managed E1 and Fractional E1 Access Device
Where to buy > See the product page > Data Sheet FCD-E1E E1 main link and sublink supporting both framed and unframed signals TDM multiplexer enables Ethernet, Sub-E1 and Serial Services over E1 One data
More informationCable Specifications and Information
APPENDIXA This appendix provides the connector and pinout information you need for making or purchasing cables used with Cisco VG350 Voice Gateway. To order cables from Cisco, see the Obtaining Technical
More informationFlexPoint T1/E1 Copper to Fiber Line Driver
BLACK BOX NETWORK SERVICES MT660A-MM MT661A-SM MT660A-MM-E MT661A-SM-E FlexPoint T1/E1 Copper to Fiber Line Driver CUSTOMER Order toll-free in the U.S.: Call 877-877-BBOX SUPPORT (outside U.S. call 724-746-5500)
More informationHow To Set Up A 366101 Modem (Marc) Model 366101 (Marc) Model 2 (Marr) Model 1 (Marm) Model 4 (Mariar) Model 8 (Marp) Model 6 (Mar
DIN Rail Mounted Leased Line Modem Users Manual 366-101 Rev. 2 Copyright 2008 Miille Applied Research Co., Inc. Houston, Texas This page is left blank intentionally Page i TABLE OF CONTENTS LIST OF FIGURES...
More informationT3 Mux M13 Multiplexer
T3 Mux M13 Multiplexer User Manual [Type the abstract of the document here. The abstract is typically a short summary of the contents of the document. Type the abstract of the document here. The abstract
More informationDate Rev. Details Author
Jtech engineering ltd J - Te c h E n g i n e e ring, L t d. 11080 Bond Boulevard Delta BC V4E 1M7 Canada Tel: 604 543 6272 Fax: 604 543 6476 http://www.jtecheng.com AUTODIALER USER S MANUAL REVISION HISTORY
More informationFCD-E1LC, FCD-T1LC Managed E1/T1 or Fractional E1/T1 Access Units
Where to buy > See the product page > Data Sheet FCD-E1LC, FCD-T1LC Managed TDM multiplexers for access to full or fractional E1/T1 services Managed access units for E1/T1 or fractional E1/T1 service E1/T1
More informationUSER MANUAL GUIMGR Graphical User Interface Manager for FRM301/FRM401 Media Racks
USER MANUAL GUIMGR Graphical User Interface Manager for FRM301/FRM401 Media Racks CTC Union Technologies Co., Ltd. Far Eastern Vienna Technology Center (Neihu Technology Park) 8F, No. 60 Zhouzi St. Neihu,
More informationMoxa TCC-100/100I User s Guide
Moxa TCC-100/100I User s Guide Seventh Edition, June 2008 www.moxa.com/product 2008 Moxa Inc., all rights reserved. Reproduction without permission is prohibited. Moxa TCC-100/100I User s Guide The software
More informationISHIDA BC-3000. Scale to Scale Communications
ISHIDA BC-3000 Scale to Scale Communications Setup Procedure & Operating Instructions March 2006 PN 94561 Revision History Date Page Description March 2006 Initial publication August 2006 2 Added RS-232
More informationTeleservice via RS232 interface XC100/XC200
User Manual 10/10 MN0500005Z-EN replaces 07/04 AWB74-1490GB Teleservice via RS interface XC100/XC00 All brand and product names are trademarks or registered trademarks of the owner concerned. Emergency
More informationCTC Union Technologies Co.,Ltd. Far Eastern Vienna Technology Center (Neihu Technology Park) 8F, No. 60 Zhouzi St., Neihu, Taipei 114, Taiwan
CTC Union Technologies Co.,Ltd. Far Eastern Vienna Technology Center (Neihu Technology Park) 8F, No. 60 Zhouzi St., Neihu, Taipei 114, Taiwan T +886-2-26591021 F +886-2-26590237 E sales@ctcu.com info@ctcu.com
More informationORION TELECOM NETWORKS INC. T1
RION TELECOM NETWORKS ORION TELECOM NETWORKS INC. T1 Protection (Fail-Over) Switch Product Brochure & Data Sheet Headquarters: Phoenix, Arizona Orion Telecom Networks Inc. 20100, N 51st Ave, Suite B240,
More informationCable Specifications. T3 Trunk Cabling APPENDIX
APPENDIX B This appendix contains details on the MGX 8230 cabling. It includes the following sections: T3 Trunk Cabling Frame Relay Cabling DC Power Cabling AC Power Cabling Control and Clock Cabling External
More informationCDI-S100 SERIAL INTERFACE CARD
CDI-S100 SERIAL INTERFACE CARD R R SERIAL INTERFACE MODULE MUSIC MUTE L L GAIN 0 LINE 5 LINE 6 db -10 + 10 MIC LEFT RIGHT FUSE 230V RATING 115V T100mA T200mA POW Installation Guide 2 CDI-S100 Installation
More informationDV-1D Data/Voice DSU TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...8 SECTION 3 - INSTALLATION...11
DV-1D Data/Voice DSU TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...8 SECTION 3 - INSTALLATION...11 SECTION 4 - OPERATION...18 SECTION 5 - FRONT PANEL CONTROLS AND INDICATORS...25
More informationDataSMART 554 & 558 T1/FT1 Plug-in DSU/CSUs Page 1 of 8. T1/FT1 Single-port Plug-in DSU/CSUs
554 & 558 T1/FT1 Plug-in DSU/CSUs Page 1 of 8 = PDF Leased Line Economical T1 Internet Access Central Site T1 Management T1/FT1 Single-port Plug-in DSU/CSUs Key Features Specifications Ordering Information
More informationINSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930
INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................
More informationThe Analyst RS422/RS232 Tester. With. VTR, Monitor, and Data Logging Option (LOG2) User Manual
12843 Foothill Blvd., Suite D Sylmar, CA 91342 818 898 3380 voice 818 898 3360 fax www.dnfcontrolscom The Analyst RS422/RS232 Tester With VTR, Monitor, and Data Logging Option (LOG2) User Manual Manual
More informationTechnical Manual. For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI
Technical Manual For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI Caller ID.com WHOZZ CALLING? POS 2 Caller ID Monitoring Unit Technical Manual For use with Caller ID signaling
More informationMDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE. USER GUIDE Document reference : 9010709-03
MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE USER GUIDE Document reference : 9010709-03 If you have questions about the MDM192 or desire assistance, contact ETIC TELECOMMUNICATIONS at the following
More informationOptimux-134, Optimux-125
Data Sheet Optimux-134, Optimux-125 Up to 16 E1/T1 links, full bandwidth 100 Mbps Ethernet traffic and high-speed data multiplexed into fiber optic uplink 25/34 Mbps or 125/134 Mbps operation s Single-,
More informationApplication Note 83 Fundamentals of RS 232 Serial Communications
Application Note 83 Fundamentals of Serial Communications Due to it s relative simplicity and low hardware overhead (as compared to parallel interfacing), serial communications is used extensively within
More informationCable Guide. Click on the subject to view the information. Digi Cables Building Cables General Cable Information
Cable Guide Click on the subject to view the information. Digi Cables Building Cables General Cable Information Digi Cables Click on the subject to view the information. Digi Connector Options Digi Connector
More informationALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL
ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL INTRODUCTION... 2.. TECHNICAL DATA... 3 ACCESSORIES... 5. INSTALLATION... 7 OPERATION... 12. TECHNICAL INFORMATION... 13 MAINTENANCE... 14. CONFIGURATIONS...
More informationALARMS-xx. Remote Alarm Unit Setup Guide 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 RESET ALL
Remote Alarm Unit Setup Guide 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 RESET ALL User s Guide Version 1.0 07/01/2009 Michael Stevens & Partners Ltd. has made
More informationFAST TUTORIALS FOR TIME-CHALLENGED TECHNICIANS
Tech Notes from a Telephone Engineer FAST TUTORIALS FOR TIME-CHALLENGED TECHNICIANS DDS Description: DDS Digital Data Service Long held industry acronym for transporting digital data at rates of: 2.4kbps,
More informationIMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions
IMMS-CCC IMMS-CCC Hardwire Central Interface Installation Instructions TABLE OF CONTENTS... Choose a Location... 1 Connections... 2 Operations... 3 Software Configuration... 4 Troubleshooting... 5 Loopback
More informationModbus Communications for PanelView Terminals
User Guide Modbus Communications for PanelView Terminals Introduction This document describes how to connect and configure communications for the Modbus versions of the PanelView terminals. This document
More informationIP DSLAM IDL-2402. Quick Installation Guide
IP DSLAM IDL-2402 Quick Installation Guide Table of Contents Package Contents... 3 Overview... 4 Setup the IDL series IP DSLAM... 5 Safety Instruction... 5 Hardware Installation... 6 WEB Configuration...
More informationSTATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625 METRIC SPECIFICATIONS FOR RS232 LEASED LINE MODEMS (LOW SPEED MODEL 400)
STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625 METRIC SPECIFICATIONS FOR RS232 LEASED LINE MODEMS (LOW SPEED MODEL 400) N.J. Specification No. Effective Date: July 1, 2001 New
More informationBLACK BOX. T1/E1 Link Extenders OCTOBER 2007 MT195A-T1 MT196A-E1
BLACK BOX NETWORK SERVICES OCTOBER 2007 MT195A-T1 MT196A-E1 T1/E1 Link Extenders Important This is a Class A device and is intended for use in a light industrial environment. It is not intended nor approved
More informationNotes Odom, Chapter 4 Flashcards Set: http://www.flashcardmachine.com/1162711/b41c
EDTECH 552 (SP11) Susan Ferdon Notes Odom, Chapter 4 Flashcards Set: http://www.flashcardmachine.com/1162711/b41c telco Leased Line CSU/DSU Local Telephone Company Owns the cables and has right of way
More information2-Pair HDSL1 Adtran Fiber Optic Link System
ISSUE 2 June 01, 2004 Data Sheet #37 2-Pair HDSL1 Adtran Fiber Optic Link System Contents 1. General. 1 2. Application... 2 3. Housings.. 2 4. Installation 3 5. Provisioning. 5 6. LED Indicators. 6 7.
More informationLow Speed Modems for Dial and Leased Circuits 2400E-2 (Stand Alone) 2400R-2 (Rack Mount) 2400E-4 (Stand Alone) 2400R-4 (Rack Mount)
Low Speed Modems for Dial and Leased Circuits 2400E-2 (Stand Alone) 2400R-2 (Rack Mount) 2400E-4 (Stand Alone) 2400R-4 (Rack Mount) QUALITY COMMUNICATIONS PRODUCTS Made in the U.S.A. 11-1010-002 INTRODUCTION
More informationOptimux-34, Optimux-25
Data Sheet Optimux-34, Optimux-25 Up to 16 E1/T1 links and high-speed data or Ethernet traffic multiplexed into fiber optic uplink E3 copper uplink for Optimux-34 Single-mode, multimode, single-mode over
More informationFrame Relay Cabling This section describes the cabling and connector pinouts for the Frame Relay cards.
A P P E N D I B Cabling Summary Introduction This appendix contains details on the MG 8850 cabling. Note In all cable references, the transmit direction is away from the switch, and the receive direction
More informationCable Specifications and Information
APPENDIX A This appendix provides the connector and pinout information you need for making or purchasing cables used with Cisco VG224 voice gateway. To order cables from Cisco, see the Obtaining Technical
More informationConnector and Cable Specifications
APPENDIXB This chapter describes the connector and cable specifications. Connector Specifications, page B-1l Cable and Adapter Specifications, page B-5 Connector Specifications 10/100/1000 Ports, page
More informationOptimux-134, Optimux-125
Optimux-134, Optimux-125 Up to 16 E1/T1 links, full bandwidth 100 Mbps Ethernet traffic and high-speed data multiplexed into fiber optic uplink 34/25 Mbps or 134/125 Mbps operation s Single-, multi, single-
More informationKeysight N4877A Clock Data Recovery and Demultiplexer 1:2
Keysight N4877A Clock Data Recovery and Demultiplexer 1:2 Getting Started Getting Started with the Keysight N4877A Clock Data Recovery and Demultiplexer 1:2 You only need a few minutes to get started
More informationKOM200. Industrial Serial to Fiber Media Converter. User s Manual
KOM200 s Manual 200911 KOM200 Industrial Serial to Fiber Media Converter s Manual KYLAND Technology Co., Ltd. 1 KOM200 s Manual 200911 Table of contents CHAPTER 1: PRODUCT OVERVIEW---------------- 3 CHAPTER
More informationRJ11 RS-232 Interface
H NS TN30 RJ11 RS-232 Interface 1.0 General The back panel of the CPP-3794 provides a combination of 9 pin DB connectors and RJ11 connectors for connecting RS-232 serial cables. The 9 pin DB connector
More informationTECHNICAL TBR 14 BASIS for April 1994 REGULATION
TECHNICAL TBR 14 BASIS for April 1994 REGULATION Source: ETSI TC-BTC Reference: DTBR/BTC-02038 ICS: 33.040.40 Key words: ONP, leased line Business TeleCommunications (BTC); 64 kbit/s digital unrestricted
More informationINTERNATIONAL TELECOMMUNICATION UNION
INTERNATIONAL TELECOMMUNICATION UNION )454 6 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU $!4! #/--5.)#!4)/. /6%2 4(% 4%,%0(/.%.%47/2+ ")43 0%2 3%#/.$ $50,%8 -/$%- 34!.$!2$):%$ &/2 53% ). 4(% '%.%2!,
More informationRack mounted telephone- and leased line modem for industrial applications
Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as
More informationVOICE RECORDING SYSTEM ISDN PRI / BRI
Sense Box VOICE RECORDING SYSTEM ISDN PRI / BRI / Analog SUB-SYSTEM ISDN2, ISDN30 Sense Box USER MANUAL TABLE OF CONTENTS 1. STATUTORY INFORMATION... 3 1.1 SAFETY WARNING... 3 1.2 SAFETY EXTRA LOW VOLTAGE
More informationChapter 2 - The TCP/IP and OSI Networking Models
Chapter 2 - The TCP/IP and OSI Networking Models TCP/IP : Transmission Control Protocol/Internet Protocol OSI : Open System Interconnection RFC Request for Comments TCP/IP Architecture Layers Application
More informationFanuc 0 M/T Model C Serial (RS232) Connection Guide
Memex Automation Inc., Burlington, Ontario Canada L7N 1 http://www.memex.ca Fanuc 0 M/T Model C Serial (RS232) Connection Guide The Fanuc 0-C control has two RS-232 interfaces. Interface number 1 (M5)
More informationConnector and Cable Specifications
APPENDIX B This appendix provides the following cabling and pinout information for the Cisco IAD1101 integrated access device: Console Port Signals and Pinouts Ethernet Connector Pinouts Analog Subscriber
More information5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...
More informationAdvanced Data Capture and Control Systems
Advanced Data Capture and Control Systems Tronisoft Limited Email: sales@tronisoft.com Web: www.tronisoft.com RS232 To 3.3V TTL User Guide RS232 to 3.3V TTL Signal Converter Modules P/N: 9651 Document
More informationMANUAL PC1000R INFO@APART-AUDIO.COM
MANUAL PC1000R INFO@APART-AUDIO.COM Features The APart PC1000R is a professional multisource CD/USB/SD card music player, equipped with balanced and unbalanced analog outputs, coaxial and optical digital
More informationLoop-IP6700 TDMoEthernet
Loop- Description Loop- is designed to transport /T1/DTE/E3/DS3 signal with timing plus Ethernet traffic over IP network, electrical or optical. This is a cost effective way of migrating to IP network
More informationInstallation and Operation Manual. Intraplex. DA-191B Four-Port Asynchronous Data Module. Version 1. GatesAir.com
Installation and Operation Manual Intraplex DA-9B Four-Port Asynchronous Data Module Version GatesAir.com Publication Information 204 GatesAir, Inc.. Proprietary and Confidential. GatesAir considers this
More informationZypcom Application Note
Zypcom Application Note Product: Z34-SX, Z34-RX, Z34-SE, Z34-RE, Z32t-SX, Z32t-SE, Z32t-RX, Z32b-SX, Z32b-SE, Z32b-RE and Z32b-RX Application: Leased Line Operation with Synchronous Data Synchronous leased
More informationRS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: 91-79-4002 4896 / 97 / 98 (M) 0-98253-50221 www.interfaceproducts.info
RS232C < - > RS485 CONVERTER S MANUAL Model: LD15U INTRODUCTION Milestone s model LD-15U is a RS232 to RS 485 converter is designed for highspeed data transmission between computer system and or peripherals
More informationApplication Note - Connecting an Electricity Meter to SolarEdge Devices (Europe and APAC)
February 2015 February 2015 Application Note - Connecting an Electricity Meter to SolarEdge Devices (Europe and APAC) This document describes how to connect an electricity meter to a SolarEdge device (inverters,
More informationTelephone- and leased line modem for industrial applications TD-36
Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased
More informationSingle channel data transceiver module WIZ2-434
Single channel data transceiver module WIZ2-434 Available models: WIZ2-434-RS: data input by RS232 (±12V) logic, 9-15V supply WIZ2-434-RSB: same as above, but in a plastic shell. The WIZ2-434-x modules
More information2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide
2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide 1. Introduction Thank you for purchasing this 2-Port RS232/422/485 Combo Serial to USB Adapter.
More informationProduct Overview. Features CHAPTER
CHAPTER 1 This chapter describes the Cisco IAD1101 integrated access device chassis, and the line interface modules supported by the Cisco IAD1101. This chapter includes the following sections: Features
More informationLoop-IP6700 TDMoEthernet
Loop-IP6700 TDMoEthernet Description Feature 1U height WAN port One electric Ethernet (10/100 BaseT) or optical Ethernet (10/100 Base-FX) Tributary ports TDM interfaces low speed, up to 4 E1/T1 low speed,
More information0832 Dot Matrix Green Display Information Board User s Guide
0832 Dot Matrix Green Display Information Board User s Guide DE-DP105_Ver1.0 0832 DOT MATRIX GREEN DISPLAY INFORMATI BOARD USER S GUIDE Table of contents Chapter1.Overview... 1 1.1. Welcome... 1 1.2. Quick
More informationPerle 10/100 Ethernet Media Converters
Perle 10/100 Ethernet Media Converters Installation Guide S-110-XXXXXX S-110-XXXXXX-XT P/N 5500302-16 (Rev B) Overview This document contains instructions necessary for the installation and operation of
More informationConnecting instruments serially to your computer
Connecting instruments serially to your computer This TechNote will review how to connect instruments (GPS, Sounder, Heading Sensor ) to a computer. Important points such as electrical specification (RS-232
More informationT1 Networking Made Easy
T1 Networking Made Easy 1 THE T1 CARRIER 3 WHAT DOES A T1 LOOK LIKE? 3 T1 BANDWIDTH 3 T1 PHYSICAL CHARACTERISTICS 4 T1 FRAMING 5 LINE CODE 6 T1 NETWORKING 6 TELCOS 6 PSTN ACCESS WITH A T1 8 SUMMARY OF
More informationCable Pinouts. SRP I/O Module
Cable Pinouts C This appendix lists the cables and connector pinout assignments for the cables used with the ERX-700 series and ERX-1400 series. Topic Page SRP I/O Module C-1 CT1 and CE1 I/O Modules C-4
More informationMODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE
DESCRIPTION MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE DESCRIPTION The SST Model 5010 Two Channel Smoke/Fire Detection Module provides two independent detection input channels for the NOVA-5000
More informationNSI DIGITAL DIMMING SYSTEM DDS 9800 DIMMER PACKS
NSI DIGITAL DIMMING SYSTEM NSI DIGITAL DIMMING SYSTEM DDS 9800 DIMMER PACKS Software Revision 1.41, Version C UL, Mfg Q3/96, and above SPECIFICATIONS Number of Channels: 9800 : 8 channels Output capacity:
More informationRuby SuperSystem Bulletin Hardware & Software Support Services. Bulletin
Ruby SuperSystem Bulletin Hardware & Software Support Services Bulletin NO: 08.00 Subject: Products: Publication Date: Author: Wayne Board All Wayne Ruby SuperSystem Installations Utilizing DCPT s January
More informationINTERNATIONAL TELECOMMUNICATION UNION
INTERNATIONAL TELECOMMUNICATION UNION )454 6 TER TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU $!4! #/--5.)#!4)/. /6%2 4(% 4%,%0(/.%.%47/2+ ")43 0%2 3%#/.$ $50,%8 -/$%- 53).' 4(% %#(/ #!.#%,,!4)/. 4%#(.)15%
More informationSetting Up and Testing the MAX Hardware
Page 1 of 12 Setting Up and Testing the MAX Hardware This chapter covers these topics: Planning the hardware installation Inserting an expansion card Setting up the hardware Connecting to input power Connecting
More informationFiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers
Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers Analog Data Links Multi-Channel Contact Closures Multiplexers Digital Data Links - Contact Closures Power Supply
More informationRFS-805. Digital Modulator AV to COFDM. User Manual
RFS-805 Digital Modulator AV to COFDM User Manual 1. Purpose of use RFS-805 is a digital modulator designed for a processing audio and video signals into COFDM (DVB-T) multiplex. 2. Installation The connections
More informationUSB to RS-422/485 Serial Adapter
USB to RS-422/485 Serial Adapter User Manual Ver. 2.00 All brand names and trademarks are properties of their respective owners. Contents: Chapter 1: Introduction... 3 1.1 Product Introduction... 3 1.2
More informationEncore Controller to Router Connections
Encore Presentation System Encore Controller to Router Connections Contents: Scope... 2 EXT COMM Pinouts... 2 Cable Connection Straight Through... 3 Cable Connection Null Modem... 3 Lantronix Ethernet
More informationXPort Universal Demo Board User Guide
XPort Universal Demo Board User Guide Part Number 900-563 Revision A September 2009 Copyright and Trademark Contacts 2009 Lantronix. All rights reserved. No part of the contents of this book may be transmitted
More informationAPPLICATION NOTE. Leased Line Modem. Leased Line Modem...3. Introduction... 3. Key Concepts... 4
Issue Date 02/18/02 APPLICATION NOTE Leased Line Modem Leased Line Modem...3 troduction... 3 Key Concepts... 4 Application Details...4 Theory of Operation...6 Components...8 Planning Considerations...10
More informationLevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual
LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual Ver. 1.0.0-0711 1 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital
More informationHP UPS R1500 Generation 3
HP UPS R1500 Generation 3 Installation Instructions Part Number 650952-001 NOTE: The rating label on the device provides the class (A or B) of the equipment. Class B devices have a Federal Communications
More informationDS26303 OCTAL 3.3V T1/E1/J1 SHORT HAUL LIU PRODUCT BRIEF
DS26303 OCTAL 3.3V T1/E1/J1 SHORT HAUL LIU PRODUCT BRIEF www.maxim-ic.com FEATURES Eight complete E1, T1, or J1 short haul LIUs Independent E1 or T1 or J1 selections for each of the LIU s in non-hardware
More informationVIEW. SLX300 SpeakerLinX IP Zone. Amplifier Installation and Setup Guide. AVoIP
VIEW SLX300 SpeakerLinX IP Zone Amplifier Installation and Setup Guide TM AVoIP ClearOne 5225 Wiley Post Way Suite 500 Salt Lake City, UT 84116 Telephone 1.800.283.5936 1.801.974.3760 Tech Sales 1.800.705.2103
More informationOne Port Serial Server Users Manual Model ESP901, ESP901E
One Port Serial Server Users Manual Model ESP901, ESP901E Documentation Number: ESP901-2303 International Headquarters B&B Electronics Mfg. Co. Inc. 707 Dayton Road -- P.O. Box 1040 -- Ottawa, IL 61350
More information