Steam Conditioning Valves and Turbine Bypass Systems
|
|
|
- Patience Gregory
- 9 years ago
- Views:
Transcription
1 Steam Conditioning Valves and Turbine Bypass Systems
2 The love of invention never stops Carl Friedrich Benz ( )
3 Technology from Germany changed plant construction for generations. The gas power plant of Bochum Verein was the most advanced of its time (1902)
4 Living Values for over 90 years
5 Taking responsibility
6 A passion for technology
7 Count on experience
8 1919 BOMAFA Armaturen GmbH Development, Manufacturing, Service 2012 BOMAFA India Manufacturing and Service for India BOMAFA Group 2010 H+G Maschinenbau GmbH Precise machining of large 1988 asfa Antriebssysteme GmbH Development of actuator systems
9 Today the BOMAFA Group is one of the leading suppliers for special valve solutions in Germany
10 Each BOMAFA valve comprises the experience of over 1000 projects worldwide
11
12 Customized HP-IP-LP systems for the steam generation of tomorrow
13 HP Turbine Bypass Systems for the latest 1000 MW powerplants
14 IP Bypass Valves
15 LP Turbine Bypass Systems for large steam volumes
16 Precise steam conditioning valves for processing industries (Ethanol, Pulp and Paper, Chemistry, Steal )
17 Variety of BOMAFA Valves HP Gate Valves HP WIV Valves Dump Tubes Desuperheater
18 Efficiency through BOMAFA Know-How Safe pressure reduction and highest controllability Precise desuperheating close to saturated steam Solutions for unique applications
19 Customized steam conditioning valves pay for themselves in a short period of time. They prevent steam losses, vibrations, noise and water hammer. Precise steam cooling to 5 C over saturated steam is possible. BOMAFA develops such valves for 90 years
20 Turbine Bypass Valves (HP - IP - LP) field of application Taking over of the steam in case of Turbine Trip, start up and shut down condition Bypassing of the steam to the next lower intermediate system or to the condenser Turbine Bypass Valves are responsible for the pressure reduction as well as the temperature reduction in the same value as the turbine
21 Pressure reduction and desuperheating in a cyclic process of a Power Plant with single re-heater 1->2 Pressurerizing of the fluid (Pump) 2->3 Heating, Vapourization, Superheating 3->4 Expansion in the HP Part of the Turbine, generation of technical Energy 3->4 Pressure reducing HP Bypass mode 4 ->4 Desuperheating, HP Bypass mode 4->5 Isobaric reheating 5->6 Expansion in the LP Turbine, generation of technical Energy 5->6 Pressure reducing in LP Bypass mode 6 ->6 Desuperheating in LP Bypass mode 6->1 Condensation
22 Steam conditioning and turbine bypass valves Actuator Inlet Pressure reduction Desuperheating Outlet
23 Principles of pressure reduction Connected systems with pressure differences have balancing ambition Leading values are the pressure P1, P2, temperatures T1, T2 and the connecting area A. The medium flow goes from system 1 to system 2 with the velocity v Depending on the pressure difference between the 2 systems, the velocity develops respectively. For steam: subcritical (p2/p1 > 0,546) critical (p2/p1 = 0,546) overcritical(p2/p1 < 0,546)
24 Noise control by careful selection of pressure reduction Example: Pressure vessel Atmospheric pressure (p1 = 10 bar) (p2 = 1 bar) 10bar 5,46bar 2,98bar 1,63bar 1bar Max. reduction of pressure by factor 0,546 per stage
25 Noise control by careful selection of pressure reduction Realistic Example: HP System: p1 = 125 bar, T1 = 560 C IP System: p2 = 32 bar, T2 = 340 C to 400 C. Stages Free Area Pressure Reduction Temperature Stage Enthalpie Mass n A [cm 2] p Stufe [bar(a)] T [ C] HD [kj/kg] M Punkt [t/h] ,0 560, x0,79=98,8 549, ,8x0,79=78,0 541, x0,79=61,6 534, ,6x0,79=48,7 528, ,7x0,79=38,5 524, ,5x0,79=32,0 521,
26 Subcritical pressure reduction Easy to maintain by modular design Components for pressure reduction are made of solid materials Seat and plug nitrided or stellited Complete controlability over all stages Inlet Subcritical multistage pressure reduction
27 Pressure reduction with motive steam extraction Valve closed
28 Pressure reduction with motive steam extraction Valve opened by 5% extraction of motive steam
29 Pressure reduction with motive steam extraction Vave opened by 20%
30 Pressure reduction with motive steam extraction Valve opened by 100%
31
32 Desuperheating Motive steam A motive steam assisted desuperheating will be selected for critical applications - cooling close to saturated vapor, small volume of flow or continuous operation. The motive steam is taken after the first pressure reduction stage and passed through a nozzle. There it is accelerated by the design of the nozzle together with the injected water and mixed. This procedure requires only very short evaporation distances. Efficient vaporization Short distances for vaporization Best conditions for temperature measuring No touching of internals by water Optimum for min. flow conditions <5% of max. flow Desuperheating close to saturation temperature possible (ca. 1 to 5 C superheated)
33 Pipe to stabilize the nozzle Water inlet Direct motive steam injection Two-substance nozzle for optimized mixing of steam and water Motive Steam Desuperheating
34
35 BOMAFA valve with motive steam desuperheating 6 Stages Leakage Class V Pressure Seal Body made of F 91
36 Desuperheating Radial Desuperheater Radial desuperheaters are based on the principle of pressurized atomization. By their design with up to 21 nozzles, they are particularly suitable for the injection of large water loads. The individual nozzles are connected with a ring line. The injection of water is controlled via a separate valve and the spring load of the individual nozzles. Optimized for the injection of large water loads High controllability by spring loaded nozzles Easy exchange of single nozzles possible No touching of internals by water
37 Radial Desuperheater
38 Special Topic
39 Avoidance of corrosion Corrosion of components during operation, particularly at higher temperatures Corrosion during downtime Corrosion due to external influences (seawater, aggressive environment, )
40 Active Protection (Avoid the emergence of corrosion on site) Avoid outdoor installation Preservation of valve during downtime Passive Protection (What the manufacturer can do) Provide components in aggressive environments with coatings
41 Surface treatment- Friction test after 1000 strokes of stem (material ) Stem grinded (0,1 Ra) without coating - Smooth surface - Acceptable sealing and frictional behavior Stem PVD - coated (Al Ti N) - Good sealing and frictional behavior - High corrosion protection - Good characteristics in the scratch test Inductive Coat ( Nickel based alloy ) - Inhomogeneous sight - Excellent sealing and frictional behavior - Excellent corrosion protection - Excellent characteristics in the scratch test Stem coated, Plasma nitrided - Good sealing and frictional behavior - High corrosion protection - Good characteristics in the scratch test Source: MPA Universität Stuttgart (2010): FORSCHUNGSVORHABEN AiF-Nr N / VGB-Nr. 317, Optimierung von Spindelabdichtungen in Armaturen [ ]. S. 111 ff.
42 Special Projects
43 BHEL 660 MW Project (India)
44 LP Bypass Valve Capacity: 900 t/h steam inlet Desuperheating: 431 t/h of water injected by 18 spring loaded nozzles Cooling to 155 C Material
45 LP Bypass Valve
46 South America: HP Bypass-valves for the Ethanol Industry
47 Capacity: 0,5-4 t/h incl. water Pressure Reduction: from 64 to 12 bar a Steam Conditioning Valve for process steam extraction Cooling from 490 C to 195 C (10 C superheated)
48
49 Rhein Paper Germany
50 Special design for precise desuperheating Capacity: 0,2-2 t/h incl. water Pressure: bar a Cooling to 240 C (33 C superheated)
51 Venturi desuperheater DN 50!
52 BOMAFA Worldwide Service
53 BOMAFA Service is available worldwide. Our engineers cooperate closely with local partners to guarantee smooth service works and to easily cope with special conditions on site. Local Service Centers: Asia (Thailand, India, China) Europe (Germany) South America (Brasil)
54 We are looking forward to you!
VAD. Variable Area Desuperheaters
Desuperheater overview Steam used in process plants can be superheated, that is, heated to a temperature above saturation. The excess of temperature above its saturation is called 'superheat'. Desuperheated
100DHP TM CCI DRAG Control Valve For High Pressure Turbine Bypass
100DHP TM CCI DRAG Control Valve For High Pressure Turbine Bypass 2 What is a HP Turbine Bypass Valve? It routes high pressure, high temperature steam around the HP Turbine, from the main steam line typically
VAD Variable Area Desuperheaters
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
Improved Modern Control Station for High Pressure Bypass System in Thermal Power Plant
Improved Modern Control Station for High Pressure Bypass System in Thermal Power Plant P.Karthikeyan 1, A.Nagarajan 2, A.Vinothkumar 3 UG Student, Department of EEE, S.A. Engineering College, Chennai,
Desuperheater Online Program Sizing Guidance
Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without
APPLIED THERMODYNAMICS TUTORIAL 1 REVISION OF ISENTROPIC EFFICIENCY ADVANCED STEAM CYCLES
APPLIED THERMODYNAMICS TUTORIAL 1 REVISION OF ISENTROPIC EFFICIENCY ADVANCED STEAM CYCLES INTRODUCTION This tutorial is designed for students wishing to extend their knowledge of thermodynamics to a more
Why and How we Use Capacity Control
Why and How we Use Capacity Control On refrigeration and air conditioning applications where the load may vary over a wide range, due to lighting, occupancy, product loading, ambient weather variations,
Torino Nord. Cogeneration Plant. The gas turbine. The steam generator. The Torino Nord cogeneration plant produces electricity and heat for district
PLANT TORINO NORD Iren Energia is the company in the Iren Group whose core businesses are the production and distribution of electricity, the production and distribution of thermal energy for district
C. starting positive displacement pumps with the discharge valve closed.
KNOWLEDGE: K1.04 [3.4/3.6] P78 The possibility of water hammer in a liquid system is minimized by... A. maintaining temperature above the saturation temperature. B. starting centrifugal pumps with the
A basic introduction to steam
A basic introduction to steam FOR HOT, COLD, MOIST AND DRY, FOUR CHAMPIONS FIERCE. STRIVE HERE FOR MASTERY Milton 1666 Steam Wonderful Steam Very high heat content Recyclable Clean, non toxic Biodegradable
SAMPLE CHAPTERS UNESCO EOLSS
STEAM TURBINE OPERATIONAL ASPECTS R.A. Chaplin Department of Chemical Engineering, University of New Brunswick, Canada Keywords: Steam Turbines, Operation, Supersaturation, Moisture, Back Pressure, Governing
EJECTOR AIR REMOVAL SYSTEMS ENGINEERING DATA BULLETIN # PVS-80025201-ARS PAGE 1 OF 5
BULLETIN # PVS-80050-ARS PAGE OF 5 GENERAL Air Removal Systems generally consist of dual 00% (twin-element) ejecrs, single 00% surface-type inter- & aftercondensers, suction & discharge isolation valves
VST-SE for Steam Conditioning Applications
VST-SE for Steam Conditioning Applications 2 CCI - The leader in innovative steam conditioning solutions for over 70 years. What Is a Steam Conditioning Valve? A steam conditioning valve converts steam
Skoda Supercritical Steam Turbine 660 MW
Skoda Supercritical Steam Turbine 660 MW Jiri Fiala Head of Engineering Dept. Skoda Power s.r.o. 27th of October 2010 Vrnjacka Banja - Serbia ŠKODA History Establishment of the company in 1859 Mr. Emil
Thermodynamics - Example Problems Problems and Solutions
Thermodynamics - Example Problems Problems and Solutions 1 Examining a Power Plant Consider a power plant. At point 1 the working gas has a temperature of T = 25 C. The pressure is 1bar and the mass flow
Pressure Locking & Thermal Binding In Wedge Gate & Parallel Slide Gate Valves
Pressure Locking & Thermal Binding In Wedge Gate & Parallel Slide Gate Valves CRANE Energy Flow Solutions TM Donald H. Johnson Crane Energy Flow Solutions 1 Crane Co. Resolution Made By Richard Teller
UNIT 2 REFRIGERATION CYCLE
UNIT 2 REFRIGERATION CYCLE Refrigeration Cycle Structure 2. Introduction Objectives 2.2 Vapour Compression Cycle 2.2. Simple Vapour Compression Refrigeration Cycle 2.2.2 Theoretical Vapour Compression
How To Power A Power Plant With Waste Heat
Power Generation Siemens Organic Rankine Cycle Waste Heat Recovery with ORC Answers for energy. Table of Contents Requirements of the Future Power Supply without extra Fuel Siemens ORC-Module Typical Applications
Waste Heat Recovery through Air Conditioning System
International Journal of Engineering Research and Development e-issn: 2278-067X, p-issn : 2278-800X, www.ijerd.com Volume 5, Issue 3 (December 2012), PP. 87-92 Waste Heat Recovery through Air Conditioning
An analysis of a thermal power plant working on a Rankine cycle: A theoretical investigation
An analysis of a thermal power plant working on a Rankine cycle: A theoretical investigation R K Kapooria Department of Mechanical Engineering, BRCM College of Engineering & Technology, Bahal (Haryana)
TOPIC: 191004 KNOWLEDGE: K1.01 [3.3/3.5] Which one of the following contains indications of cavitation in an operating centrifugal pump?
KNOWLEDGE: K1.01 [3.3/3.5] P21 Which one of the following contains indications of cavitation in an operating centrifugal pump? A. Low flow rate with low discharge pressure. B. Low flow rate with high discharge
Webpage: www.ijaret.org Volume 3, Issue IV, April 2015 ISSN 2320-6802
Efficiency Assessment and Improvement of at Super Thermal Power Station Vikram Singh Meena 1, Dr. M.P Singh 2 1 M.Tech in Production Engineering, Jagannath University, Jaipur, Rajasthan, India [email protected]
Development of a model for the simulation of Organic Rankine Cycles based on group contribution techniques
ASME Turbo Expo Vancouver, June 6 10 2011 Development of a model for the simulation of Organic Rankine ycles based on group contribution techniques Enrico Saverio Barbieri Engineering Department University
Sheet 5:Chapter 5 5 1C Name four physical quantities that are conserved and two quantities that are not conserved during a process.
Thermo 1 (MEP 261) Thermodynamics An Engineering Approach Yunus A. Cengel & Michael A. Boles 7 th Edition, McGraw-Hill Companies, ISBN-978-0-07-352932-5, 2008 Sheet 5:Chapter 5 5 1C Name four physical
Lesson. 11 Vapour Compression Refrigeration Systems: Performance Aspects And Cycle Modifications. Version 1 ME, IIT Kharagpur 1
Lesson Vapour Compression Refrigeration Systems: Performance Aspects And Cycle Modifications Version ME, IIT Kharagpur The objectives of this lecture are to discuss. Performance aspects of SSS cycle and
API Flanged Safety Relief Valves Series 526 CATALOG
API Flanged Safety Relief Valves Series 26 CATALOG The-Safety-Valve.com 1 Valve finder How to find the right product group High operating to set pressure ratio, high backpressure or low total height? Yes
Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.
Table V Troubleshooting Checklist for Refrigeration Systems TROUBLE POSSIBLE CAUSE CORRECTIVE MEASURE High condensing pressure. Low condensing pressure. Air or non-condensable gas in system. Inlet water
How To Calculate The Performance Of A Refrigerator And Heat Pump
THERMODYNAMICS TUTORIAL 5 HEAT PUMPS AND REFRIGERATION On completion of this tutorial you should be able to do the following. Discuss the merits of different refrigerants. Use thermodynamic tables for
Steam Jet Vacuum Pumps
By: S.G. Ketterer and C.G. Blatchley The use of steam jet ejectors for entraining air or gases at subatmospheric pressures is increasing rapidly, particularly in the range of pressures below mm absolute.
CCI 100 DPC DRAG Wellhead Production Choke Valve
CCI 100 DPC DRAG Wellhead Production Choke Valve 2 Severe service DRAG choke valve delivers precise wellhead pressure control with superior reliability and life. Improves well production time Enhances
1. A belt pulley is 3 ft. in diameter and rotates at 250 rpm. The belt which is 5 ins. wide makes an angle of contact of 190 over the pulley.
Sample Questions REVISED FIRST CLASS PARTS A1, A2, AND A3 (NOTE: these questions are intended as representations of the style of questions that may appear on examinations. They are not intended as study
Steam Turbine Concepts for the Future Volatile Power Market
Steam Turbine Concepts for the Future Volatile Power Market Power-Gen Europe June 12 14, 2012 Michael Wechsung Thomas Loeper Radim Znajda Siemens AG - Energy Sector Fossil Power Generation Agenda Situation
New Developments on Industrial Steam Turbines
New Developments on Industrial Steam Turbines Enhanced Platform The next generation of Siemens industrial steam turbines Flexibility meets Efficiency The new pre-designed multistage steam turbine SST-111
VdS 2100-09en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS 2100-09en : 2011-05 (01)
VdS Guidelines for water extinguishing systems VdS 2100-09en Requirements and test methods VdS 2100-09en : 2011-05 (01) Publishing house: VdS Schadenverhütung GmbH Amsterdamer Str. 172-174 50735 Köln,
PRESSURE REDUCER AND RELIEF VALVES WITH METALLIC BELLOW FOR WATER STEAM
PRESSURE REDUCER AND RELIEF VALVES WITH METALLIC BELLOW FOR WATER STEAM PRESSURE REDUCER AND RELIEF VALVES These devices are used to reduce and control a gaseous flow pressure (air, steam, gas ). The PRESSURE
DE-TOP User s Manual. Version 2.0 Beta
DE-TOP User s Manual Version 2.0 Beta CONTENTS 1. INTRODUCTION... 1 1.1. DE-TOP Overview... 1 1.2. Background information... 2 2. DE-TOP OPERATION... 3 2.1. Graphical interface... 3 2.2. Power plant model...
DESIGN CHALLENGES AND OPERATIONAL EXPERIENCE OF A MEGA MED SEAWATER DESALINATION PLANT IN TIANJIN
DESIGN CHALLENGES AND OPERATIONAL EXPERIENCE OF A MEGA MED SEAWATER DESALINATION PLANT IN TIANJIN Authors: Presenter: T. Efrat, Yu Haimiao Tomer Efrat Deputy Manager, Thermal Process Dept. IDE Technologies
CONTENTS. ZVU Engineering a.s., Member of ZVU Group, WASTE HEAT BOILERS Page 2
WASTE HEAT BOILERS CONTENTS 1 INTRODUCTION... 3 2 CONCEPTION OF WASTE HEAT BOILERS... 4 2.1 Complex Solution...4 2.2 Kind of Heat Exchange...5 2.3 Heat Recovery Units and Their Usage...5 2.4 Materials
Signature and ISX CM870 Fuel System
Signature and ISX CM870 Fuel System Cummins Ontario Training Center HPI-TP Fuel System Heavy Duty High Pressure Injection - Time Pressure Fuel System The fuel system developed for the Signature and ISX
High Pressure Ammonia Systems New Opportunities
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2010 High Pressure Ammonia Systems New Opportunities Andy Pearson Star Refrigeration
Solenoid valves Type EVU
Data sheet Solenoid valves EVU EVU solenoid valves are designed to fit into compact refrigeration systems. Available in direct and pilot operated versions, they can be applied in liquid, suction, and hot
POSSIBILITY FOR MECHANICAL VAPOR RE-COMPRESSRION FOR STEAM BASED DRYING PROCESSES
POSSIBILITY FOR MECHANICAL VAPOR RE-COMPRESSRION FOR STEAM BASED DRYING PROCESSES M. Bantle 1, I. Tolstorebrov, T. M. Eikevik 2 1 Department of Energy Efficiency, SINTEF Energy Research, Trondheim, Norway,
Testing methods applicable to refrigeration components and systems
Testing methods applicable to refrigeration components and systems Sylvain Quoilin (1)*, Cristian Cuevas (2), Vladut Teodorese (1), Vincent Lemort (1), Jules Hannay (1) and Jean Lebrun (1) (1) University
DEVELOPMENT OF A TWIN SCREW EXPRESSOR AS A THROTTLE VALVE REPLACEMENT FOR WATER-COOLED CHILLERS
DEVELOPMENT OF A TWIN SCREW EXPRESSOR AS A THROTTLE VALVE REPLACEMENT FOR WATER-COOLED CHILLERS J J Brasz, Carrier Corporation, Syracuse, NY, 13221, USA [email protected] I K Smith and N Stosic
Vogt Valves The Connection Bulletin for Forged Steel Flow Control Valves CB 15
The Connection Bulletin for Forged Steel Flow Control Valves CB 15 Flow Control Division Forged Steel Flow Control Valves GRADUATED DIAL AND INDICATOR FULLY GUIDED V-PORT THROTTLING DISC AND INTEGRAL HARD
Transcritical CO2 booster system How to control the system
Application guide Transcritical CO2 booster system How to control the system EKC 326A 21 ICMTS CCM AK-SC 255/ AK-SM 350/ AK-SM 720/ AKA 245 DCR 32R AKD 102 Danfoss R64-2047.10 www.danfoss.com/co2 General
Thermostatic expansion valves type TR6 REFRIGERATION AND AIR CONDITIONING. Technical leaflet
Thermostatic expansion valves type REFRIGERATION AND AIR CONDITIONING Technical leaflet Thermostatic expansion valves, type Contents Page Introduction........................................................................................3
Rusty Walker, Corporate Trainer Hill PHOENIX
Refrigeration 101 Rusty Walker, Corporate Trainer Hill PHOENIX Compressor Basic Refrigeration Cycle Evaporator Condenser / Receiver Expansion Device Vapor Compression Cycle Cooling by the removal of heat
ARP Food Industry, Portugal
Food Industry, Portugal In a Portuguese food company colibri will install a twostage ammonia-water-absorption refrigeration system. The 1st refrigeration stage provides the customer with liquid ammonia
PERFORMANCE EVALUATION OF NGCC AND COAL-FIRED STEAM POWER PLANTS WITH INTEGRATED CCS AND ORC SYSTEMS
ASME ORC 2015 3rd International Seminar on ORC Power Systems 12-14 October 2015, Brussels, Belgium PERFORMANCE EVALUATION OF NGCC AND COAL-FIRED STEAM POWER PLANTS WITH INTEGRATED CCS AND ORC SYSTEMS Vittorio
Increasing the evaporation temperature with the help of an internal heat exchanger
Increasing the evaporation temperature with the help of an internal heat exchanger A. TAMBOVTSEV (a), H. QUACK (b) (a,b) Technische Universität Dresden, D-01062, Dresden, Germany (a) Fax: (+49351) 463-37247,
A Review on Power Generation in Thermal Power Plant for Maximum Efficiency
International Journal of Advanced Mechanical Engineering. ISSN 2250-3234 Volume 4, Number 1 (2014), pp. 1-8 Research India Publications http://www.ripublication.com/ijame.htm A Review on Power Generation
SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS
SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES After studying this unit, the reader should be able to explain the purpose of the condenser in a refrigeration system. describe differences
CPX/HT Series. REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM. High-performance products. Designed for you!
CPX/HT Series REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM High-performance products. Designed for you! COMPRESSED AIR WATER CONTAMINATION Atmospheric air contains water in vapor form in different
Guidelines for Choosing and Installing Radar in Stilling Wells and Bypass Chambers
Technical Note 84-3-424, Rev CA September 212 Rosemount Radar Transmitters Guidelines for Choosing and Installing Radar in Stilling Wells and Bypass Chambers INTRODUCTION This document provides a guideline
Vacuum Control. Vacuum Applications. Vacuum Regulators. Vacuum Breakers (Relief Valves) Vacuum Control Devices. Vacuum Terminology
Vacuum Applications Vacuum regulators and breakers are widely used in process plants. Conventional regulators and relief valves might be suitable for service if applied correctly. This section provides
EXPERIMENTAL RESEARCH ON FLOW IN A 5-STAGE HIGH PRESSURE ROTOR OF 1000 MW STEAM TURBINE
Proceedings of 11 th European Conference on Turbomachinery Fluid dynamics & Thermodynamics ETC11, March 23-27, 2015, Madrid, Spain EXPERIMENTAL RESEARCH ON FLOW IN A 5-STAGE HIGH PRESSURE ROTOR OF 1000
Boiler Calculations. Helsinki University of Technology Department of Mechanical Engineering. Sebastian Teir, Antto Kulla
Helsinki University of Technology Department of Mechanical Engineering Energy Engineering and Environmental Protection Publications Steam Boiler Technology ebook Espoo 2002 Boiler Calculations Sebastian
Refrigeration and Airconditioning Prof. M. Ramgopal Department of Mechanical Engineering Indian Institute of Technology, Kharagpur
Refrigeration and Airconditioning Prof. M. Ramgopal Department of Mechanical Engineering Indian Institute of Technology, Kharagpur Lecture No. # 22 Refrigeration System Components: Compressor (Continued)
DIRECT STEAM INJECTION HOT WATER SYSTEMS FOR JACKETED HEATING
By Philip Sutter Pick Heaters, Inc. DIRECT STEAM INJECTION HOT WATER SYSTEMS FOR JACKETED HEATING INTRODUCTION Many process plants currently use steam or hot water to heat jacketed devices such as tanks,
Type 92S Pilot-Operated Steam Regulator
Type 92S Pilot-Operated Steam Regulator Introduction The Type 92S steam regulator is piston actuated for high cycle steam service which includes a Type 6492L, 6492H or pilot (see Figure 1). These pilots
The Technology and Business of Power Andrew Valencia, P.E. Lower Colorado River Authority
The Technology and Business of Power Andrew Valencia, P.E. Lower Colorado River Authority 1 2 What is Efficiency? Efficiency: What you get divided by what you pay for Heatrate is a measure of plant efficiency
V47 Series Temperature Actuated Modulating Water Valves
V47 Series Temperature Actuated Modulating Water Valves Master Catalog 125 Valves, Miscellaneous (Other Than Gas) Section V Product Bulletin V47 Issue Date 0286 Application The V47 modulating valves regulate
Steam System Best Practices Condensate System Piping
Steam System Best Practices Condensate System Piping Summary The best method for improving steam system energy efficiency, reducing chemical costs, and reducing make-up water costs is to return the maximum
INTEC Engineering GmbH Heating Solutions for the Marine Industry
INTEC Engineering GmbH Heating Solutions for the Marine Industry Thermal Oil Heaters Heating Solutions for the Marine Industry Compared to conventional plants using hot water or steam, thermal oil as a
FUNDAMENTALS OF ENGINEERING THERMODYNAMICS
FUNDAMENTALS OF ENGINEERING THERMODYNAMICS System: Quantity of matter (constant mass) or region in space (constant volume) chosen for study. Closed system: Can exchange energy but not mass; mass is constant
GE Oil & Gas. Air Cooled Heat Exchangers. Robust and reliable for all loads and applications
GE Oil & Gas Air Cooled Heat Exchangers Robust and reliable for all loads and applications What it is Air cooled heat exchangers are commonly used in industrial applications where a reliable source of
HS-901(A) BASIC STEAM HEATING SYSTEMS
HS-901(A) BASIC HEATING SYSTEMS One-Pipe Two-Pipe Basic Steam Heating Systems One-pipe steam heating system EQUALIZER SAFETY FACTOR STATIC HEAD PRESSURE DROP 2" HEATING UNIT 15" DRIP CONNECTION In a one-pipe,
VACUUM REFRIGERATION SYSTEMS
VACUUM REFRIGERATION SYSTEMS CHILL VACTOR The Croll-Reynolds CHILL-VACTOR is a chiller that uses a vapor flashing process. Water has a pressure-temperature relationship which is its boiling point. If its
Direct steam injection humidifiers
Direct steam injection humidifiers Direct steam injection gives quality control of air humidity. Research and development in separation, the use of lightweight stainless steel combined a constant temperature
Steam System Efficiency. Bill Lumsden Leidos Engineering
Steam System Efficiency Bill Lumsden Leidos Engineering Steam System Efficiency Steam System Efficiency Key Take-aways: Review of the properties of ice, water, and steam Learn the basics of steam trap
Flowserve - Edward Valves Quick Closing Isolation Valves -The Equiwedge Alternative
Flowserve - Edward Valves Quick Closing Isolation Valves -The Equiwedge Alternative Problem Fast isolation of a large bore main steam or feedwater line during a pipe rupture that seals flow in both directions.
USC Steam Turbine technology for maximum efficiency and operational flexibility. Dr. Rainer Quinkertz Andreas Ulma Edwin Gobrecht Michael Wechsung
USC Steam Turbine technology for maximum efficiency and operational flexibility Dr. Rainer Quinkertz Andreas Ulma Edwin Gobrecht Michael Wechsung Siemens AG POWER-GEN Asia 2008 Kuala Lumpur, Malaysia October
QUESTIONS THERMODYNAMICS PRACTICE PROBLEMS FOR NON-TECHNICAL MAJORS. Thermodynamic Properties
QUESTIONS THERMODYNAMICS PRACTICE PROBLEMS FOR NON-TECHNICAL MAJORS Thermodynamic Properties 1. If an object has a weight of 10 lbf on the moon, what would the same object weigh on Jupiter? ft ft -ft g
Using meters to measure steam flow
Page 1 of 6 April 1998 Plant Engineering SELECTING NEW TECHNOLOGY: PROBLEM SOLVING Using meters to measure steam flow Jesse L. Yoder, Ph.D., Senior Analyst, Automation Research Corp., Dedham, MA Key Concepts
State of the Art Energy Efficient Data Centre Air Conditioning
- White Paper - State of the Art Energy Efficient Data Centre Air Conditioning - Dynamic Free Cooling - Release 2, April 2008 Contents ABSTRACT... 3 1. WHY DO I NEED AN ENERGY EFFICIENT COOLING SYSTEM...
Commercial refrigeration has been in the environmental. Refrigerant. as a. Basics Considerations PART 1:
PART 1: CO 2 Commercial refrigeration has been in the environmental spotlight for more than a decade, especially as leakage studies have revealed the true effects of hydrofluorocarbon (HFC) emissions.
SIL in de praktijk (Functional Safety) 23.04.2015 - Antwerpen. 61508 Compliance of Actuators and Life Cycle Considerations. SAMSON AG Dr.
SIL in de praktijk (Functional Safety) 23.04.2015 - Antwerpen SAMSON AG Dr. Thomas Karte 61508 Compliance of Actuators and Life Cycle Considerations 2015-04-23 SAMSON AG Dr. Karte - 61508 Compliance of
D A T A S H E E T. TX6 Thermo Expansion Valves. Alco Controls TX6. Features. Introduction. Construction
ALCO s series of Thermo -Expansion Valves are designed for air conditioning, chillers, rooftops, close control, A/C transportation, heat pumps, industrial cooling process and refrigeration applications.
MFP14, MFP14S and MFP14SS Automatic Pumps
Page 1 of 6 TI-P136-02 ST Issue 12 Cert. No. LRQ 0963008 ISO 9001, S and SS utomatic Pumps Description The Spirax Sarco automatic pump is a displacement receiver operated by steam or compressed air. It
D A T A S H E E T. TX3 Thermo Expansion Valves. Alco Controls TX3. Features. Introduction. Description of bulb charges
ALCO s TX3 series of Thermo -Expansion Valves are designed for air conditioning, heat pumps and commercial refrigeration applications. The TX3 is ideal for those applications requiring hermetic / compact
Diaphragm Actuators Favorable Variety Pneumatic Diaphragm Actuators Electric Actuators Hydraulic Actuators
Favorable Variety Whether rotary or linear with pneumatic, electric, and hydraulic valve actuators from ARCA Regler GmbH, you always have the right solution at hand. ARCA s comprehensive product portfolio
from the turbine manufacturer.
Specifying Steam Surface Condensers by Elliot Spencer Graham Mfg.Co., Inc., Great Neck, Long Island, N.Y. Factors affecting condenser design and selection. A typical air conditioning surface condenser
Mechanical Seal Piping Plans
Mechanical Seal Piping Plans Single Seals plans 01, 02, 03, 11, 13, 14, 21, 23, 31, 32, 41 Dual Seals plans 52, 53A, 53B, 53C, 54, 55 Quench Seals plans 62, 65A, 65B, 66A, 66B Gas Seals plans 72, 74, 75,
MAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure
MAKING MODERN LIVING POSSIBLE Thermostatic valve AVTA Technical brochure 2 IC.PD.500.A3.02-520B3728 Danfoss A/S 07-2009/ RA-MC/mr Contents Page Features............................................................................................4
Best Choice BENSON BOILER. Excellent performance features make the Benson boiler the most widely used type of once-through boiler
BENSON BOILER Best Choice Excellent performance features make the Benson boiler the most widely used type of once-through boiler by JOACHIM FRANKE and RUDOLF KRAL Power for generations BENSON BOILER Best
GS-General Service Control Valves
GS-General Service Control Valves GS-General Service Valves The GS-General Service Valves continue Copes-Vulcan s tradition of designing and manufacturing control valves that provide both exceptional service
Thermodynamical aspects of the passage to hybrid nuclear power plants
Energy Production and Management in the 21st Century, Vol. 1 273 Thermodynamical aspects of the passage to hybrid nuclear power plants A. Zaryankin, A. Rogalev & I. Komarov Moscow Power Engineering Institute,
Pre-designed Steam Turbines
Industrial Power Pre-designed Steam Turbines The comprehensive product range up to 12 megawatts Scan the QR code with the QR code reader in your mobile! siemens.com / energy / steamturbines A Full Range
AB Progetti S.r.l. Phone +390112485088 Fax +390112489568 www.abprogetti.com [email protected]
AB Progetti S.r.l. Phone +390112485088 Fax +390112489568 www.abprogetti.com [email protected] STEAM JET EJECTORS AND VACUUM SYSTEMS TABLE OF CONTENT 1 GENERAL DESCRIPTION PAG. 03 1.1 SINGLE STAGE EJECTOR
MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump
MAINTENANCE INSTRUCTIONS Thermia Robust heat pump 9 6 8 0-5 4 7 4 5 0 0 1 R e v. 3 Table of contents 1 Important information.................. 2 1.1 Product description....................... 2 1.2 General................................
How To Clean Up A Reactor Water Cleanup
General Electric Systems Technology Manual Chapter 2.8 Reactor Water Cleanup System TABLE OF CONTENTS 2.8 REACTOR CLEANUP SYSTEM... 1 2.8.1 Introduction... 2 2.8.2 System Description... 2 2.8.3 Component
Oil & Gas. CHTR Centrifugal, High-pressure, Multistage Barrel Pump to API 610, 10 th Edition.
Oil & Gas CHTR Centrifugal, High-pressure, Multistage Barrel Pump to API 610, 10 th Edition. 2 Introduction CHTR Reliable delivery at high pressure. Day in and day out, KSB pumps prove their worth again
PRESSURE REDUCING VALVES
0E0-GB PRESSURE REDUCING VAVES MAIN FEATURES The pressure reducing valve is able, by varying its pressure drops, to hold the downstream pressure of the fluid at a constant level against changes in the
Characteristics of Evaporators
Characteristics of Evaporators Roger D. Holder, CM, MSME 10-28-2003 Heat or Energy In this paper, we will discuss the characteristics of an evaporator coil. The variance of the operational condenses of
Evaluation Of Hybrid Air- Cooled Flash/Binary Power Cycle
INL/CON-05-00740 PREPRINT Evaluation Of Hybrid Air- Cooled Flash/Binary Power Cycle Geothermal Resources Council Annual Meeting Greg Mines October 2005 This is a preprint of a paper intended for publication
ECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
Pressurized Water Reactor B&W Technology Crosstraining Course Manual. Chapter 9.0. Integrated Control System
Pressurized Water Reactor B&W Technology Crosstraining Course Manual Chapter 9.0 Integrated Control System TABLE OF CONTENTS 9.0 INTEGRATED CONTROL SYSTEM... 1 9.1 Introduction... 1 9.2 General Description...