MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR)
|
|
- Alexandrina Banks
- 7 years ago
- Views:
Transcription
1 MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) IMPROVING INDOOR AIR QUALITY IN NEW HOMES 1
2 NUAIRE S PEDIGREE Proud to Build British Nuaire is a world leader in the design and manufacture of fans and ventilation systems. We put our energy into efficient ventilation so you don t waste yours. Nuaire is a privately owned, British company that designs and manufactures innovative ventilation products for the residential and commercial sectors. We are proud to be recognised for our expertise, commitment to innovation and the outstanding quality of our products and customer service. People are the heart of Nuaire, and we have over 400 staff at our headquarters with a further 65 technical sales engineers throughout the UK and Ireland. Based in South Wales, our factory covers 18,000m 2, allowing us to manufacture almost all of our products on site; from small bathroom fans to large air handling units. In recent years Nuaire has invested millions of pounds into new manufacturing plant to supports its plans for growth. MADE IN GREAT BRITAIN Our manufacturing facility is approximately 4 x the size of the Wembley pitch GETTING IT RIGHT FROM THE START Nuaire s technical application team can offer expert advice and support to help you make the right choice in your ventilation strategy. Providing a simple, quick selection or offering advice on compliance with the very latest building regulations and environmental issues, we are here for you every step of the way. 2
3 Advice On Compliance and SAP Q Stay ahead of the latest building regulations and make the best product and fabric choices. Over 65 Sales Staff Field and office based staff to support you at every stage. Gold Star Aftercare Our comprehensive product warranty and dedicated after sales support gives you peace of mind. Nuaire Academy To ensure your installers get the best from your system and meet Building Regs, Nuaire offers BPEC training. This is free of charge to our customers delivered from our BPEC Accredited Training Centre. The Full Service Help with product selection, detailed parts lists and fast delivery ensure you meet your deadline and budget. 3
4 NUAIRE S MVHR MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR - System 4) Heat recovery (MVHR) is fast becoming the most popular strategy for effective whole home ventilation for new build properties. A proven low-energy, highly efficient ventilation method, Nuaire s heat recovery MRXBOX range offers all year round ventilation by extracting moisture and supplying fresh air, whilst recovering the heat that would otherwise be lost. The MRXBOXAB s is the first MVHR range on the market with integral automatic summer bypass as standard. Nuaire offers the widest range of heat recovery systems in the UK, specifically designed to meet building regulations with the best SFPs/SAP Q scores. With a range of compact wall units designed to suit every size and type of property, Nuaire will have a unit to fit the requirements of your project. With Government legislation and building regulations for low leakage rates, air-tight buildings may lead to poor indoor air quality. Nuaire s award winning, wide range of MVHR solutions are 95% efficient and will quietly and effectively provide fresh, filtered air all year round. MVHR systems will retain heat that would otherwise have been lost to outside and warm incoming fresh air, if required. MVHR How does it work? NO NEED TO OPEN WINDOWS TO VENTILATE Clean fresh air is continuously drawn into the property from outside through the supply air ducting. HIGH EFFICIENCY FILTERS HELP CREATE A HEALTHY LIVING ENVIRONMENT Clean, fresh air passes through the filter inside the unit and into the counter-flow heat exchanger, where it is warmed using the heat recovered from extract before it is delivered to the habitable rooms of the home. 4 BOOST FACILITY Both the supply and extract air can be boosted at any time by the home owner to increase the ventilation levels. Light switches, PIRs and Humidistats can be used. PREVENTS CONDENSATION BY KEEPING MOISTURE LEVELS LOW Stale air is continuously extracted from the moisture producing areas, such as kitchens and bathrooms. The MVHR unit takes advantage of the heat by absorbing up to 95% of it and storing it in the heat exchanger.
5 All the options you need Ventilation is often overlooked, or considered late in the construction when joists and other services are installed. Nuaire offer a wide range of solutions, including MVHR s for wall or ceiling mount. Nuaire also offer acoustic solutions to ensure you not only meet building regulations, but ensure efficient, whisper-quiet performance. WALL VOID Design Services Nuaire s Technical Application Team can offer expert advice and support on design. Services include supporting 3D CAD illustrations to illustrate choice of product, ducting and ancillaries. This bespoke package enables correct selection and aids project management and site control. As well as a simple, clean system layout in 3D showing ventilation, Nuaire provides a complete parts list with installation visuals. 5
6 NUAIRE S MVHR Building Regulations Part F Table 5.1a Extract Ventilation Rates Room Kitchen Intermittent Extract Continuous Extract Minimum Rate Minimum High Rate Minimum Low Rate 30 l/s adjacent to hob, or 60 l/s elsewhere Utility Room 30 l/s 8 l/s Bathroom 15 l/s 8 l/s Sanitary Accommodation 6 l/s 6 l/s Table 5.1b Whole Dwelling Ventilation Rates 13 l/s Total extract rate should be at least the whole dwelling ventilation rate given in Table 5.1b Number of bedrooms in dwelling Whole dwelling ventilation rate a.b. (l/s) Notes: a. In addition, the minimum ventilation rates should be no less than 0.3 l/s per m 2 of internal floor area (this includes all floors, e.g. for a two-storey building, add the ground and first floor areas). b. This is based on two occupants in the main bedroom and a single occupant in all other bedrooms. This should be used as the default value. If a greater level of occupancy is expected, add 4 l/s per occupant. Design of continuous mechanical extract systems System 3 (Continuous Mechanical Extract) has been sized for the winter period. Additional ventilation may be required during warmer months and it has been assumed that the provisions for purge ventilation (e.g. openable windows) could be used. Step 1: Determine the whole dwelling ventilation rate from Table 5.1b. (Note: no allowance is made for infiltration as the extract system lowers the pressure in the dwelling and all air flow through infiltration paths does not increase the overall ventilation rate.) Step 2: Calculate the whole dwelling extract ventilation rate by summing the individual room rates for minimum high rate from Table 5.1a. (For sanitary accommodation only, as an alternative, the purge ventilation provisions can be used where security is not an issue. In this case the minimum high extract rate for the sanitary accommodation should be omitted from the Step 2 calculation.) Step 3: The required extract rates are as follows: The maximum whole dwelling extract ventilation rate (i.e. the boost rate) should be at least the greater of Step 1 and Step 2. Note that the maximum individual room extract rates should be at least those given in Table 5.1a for minimum high rate. Location of Ventilation Devices Extract should be from each wet room. Mechanical extract terminals and fans should be installed as high as is practicable and preferably less than 400mm below the ceiling. Where ducts etc are provided in a dwelling with a protected stairway, precautions may be necessary to avoid the possibility of the system allowing smoke or fire to spread into the stairway. Air Transfer To ensure good transfer of air throughout the dwelling, there should be an undercut of minimum area 7600mm 2 in all internal doors above the floor finish. This is equivalent to an undercut of 10mm for a standard 760mm width door. This should be achieved by making an undercut of 10mm above the floor finish if the floor finish is fitted, or by a 20mm undercut above the floorboards, or other surface, if the finish has not been fitted. Controls Should be set up to operate without occupant intervention, but may have manual or automatic controls to select the boost rate. Any manual boost controls should be provided locally to spaces being served, e.g. bathrooms and kitchen, as provision of a single centrally located switch may result in fans being left in an inappropriate mode of operation. Automatic controls could include sensors for humidity, occupancy/usage and pollutant release. Humidity controls should not be used for sanitary accommodation as odour is the main pollutant. In kitchens, any automatic control must provide sufficient flow during cooking with fossil fuel (e.g. gas) to avoid build up of combustion products. Ensure that the system always provides the minimum whole dwelling ventilation rate specified in table 5.1b. Where manual controls are provided, they should be within reasonable reach of the occupants. It is recommended that they are located in accordance with the guidance of Requirement N3 Safe Opening And Closing of Windows etc., which is given in Approved Document N. Where reasonable, pull cords, operating rods or similar devices should be provided. Noise Any continuously running fans should be quiet so as not to discourage their use by occupants. The minimum whole dwelling extract ventilation rate should be at least the whole dwelling ventilation rate found in Step 1. 6
7 MVHR Product Selector WALL MOUNTED LOW PROFILE Page No MRXBOX95 -WM1 MRXBOX95AB -WM1 MRXBOX95 -WM2 MRXBOX95AB -WM2 MRBOX95 -WH1 MRXBOX95AB -WH1 MRXBOX95AB -WH2 MRXBOX95B -LP1 Feature For properties up to 60m 2 /660ft 2 For properties up to 60m 2 /660ft 2 For properties up to 100m 2 /1100ft 2 For properties up to 100m 2 /1100ft 2 For properties up to 150m 2 /1600ft 2 For properties up to 150m 2 /1600ft 2 For properties up to 270m 2 /2900ft 2 For properties up to 100m 2 /1100ft 2 Kitchen + up to 2 wet rooms Kitchen + up to 5 wet rooms Kitchen + up to 6 wet rooms Kitchen + up to 7 wet rooms Kitchen + up to 8 wet rooms Discreet Run Monitor Integral automatic summer bypass Optional automatic summer bypass Integral frost protection Integral humidistat Optional sensors and detectors Optional remote commissioning box Summertime boost facility MRXBOX-VSC LCD Controller compatible 7
8 TOTAL CONTROL WITH THE LIGHTEST TOUCH...what a breath of fresh air Simple, intuitive and discreet, the Nuaire LCD control - MRXBOX-VSC puts you in total control of your MVHR system. With a wide range of functions and settings, no other product gives you the freedom to tailor performance, while saving energy. For more details call enquiries@nuaire.co.uk or visit
9 NUAIRE S MVHR CONTROL Touch Screen Controller for MVHR: MRXBOX-VSC The stylish touch screen wired controller has been designed to make controlling your MVHR ventilation system simple, for both the installer and the end user. With a 3.2 touch screen display, the unit can be surface or semi-recess mounted and is compatible with standard 2 gang recess back box. DIMENSIONS 85mm 73mm = Screen width 35mm = Surface mounting depth When installing the MVHR, you can commission the unit through the controller and program settings such as air flow, frost protection and summer bypass. For the end user, they will be able to tailor the unit to suit their lifestyle, through setting a timed or rising boost, or even putting the unit into holiday or night mode to save on energy. 145mm 57mm = Screen depth 6mm = Recessed mounting depth FLEXIBLE CONTROL OPTION 9
10 NUAIRE S MVHR MRXBOX95AB-WM1 (with automatic summer bypass) & MRXBOX95-WM1 The MRXBOXB95AB-WM1 has been designed with automatic summer bypass and the facility to commission the supply and extract fans independently on both minimum and maximum speeds, in addition to the features you will find on the standard MRXBOX95-WM1. Sensors for the MRXBOX95(AB) WM1 include: MRXBOX95-PIR (Passive Infra Red) - A low voltage sensor, detects movement and activates system. Incorporates overrun timer and timer adjustments. MRXBOX95-HUM - A low voltage sensor, activates the system when the RH level is above set point. Incorporates overrun timer and RH set point level adjustment. Both the MRXBOXBOX95AB-WM1 and MRXBOX95-WM1 are designed to provide optimised balanced (supply and extract) mechanical ventilation with heat recovery. Tempered air is delivered into living areas whilst extracting moisture laden air from wet areas, creating comfortable well - ventilated homes. The unit uses the latest generation of low voltage DC fans and motors, counter flow heat exchanger and easy accessible controls. The heat exchanger block can recover up to 95% of the normally wasted heat. The two independent fans have full speed control for background and boost ventilation rates as well as a run-on timer facility and adjacent smoke detectors. Both units are listed on the Product Characteristics Database. MRXBOX95-RFI - If fan failure occurs, the audio visual indicator will flash a warning. Typical Installation INSTALLATION FEATURES Filter being removed Filter cover Filter Code MVHR-WM1-FILTERKIT 10
11 Performance - MRXBOX95(AB)-WM CODE DESCRIPTION MRXBOX95-WM Fan Static Pressure (Pa) Multi-room supply and extract heat recovery 2. Product range 3. Efficiency 4. Wall/cupboard application 5. Medium duty MRXBOX95 AB -WM Air Volume Flow Rate (l/s) Multi-room supply and extract heat recovery 2. Product range 3. Efficiency 4. Automatic Summer Bypass 5. Wall/cupboard application 6. Medium duty Electrical & Sound Maximum power consumption Sound Power Levels db re 1pW Curve (Watts) K 2K 4K 8K Curve 1 71 Open inlet Open Outlet Breakout Open inlet Open Outlet Breakout Open inlet Open Outlet Breakout Open inlet Open Outlet Breakout Open inlet <10 Open Outlet Breakout The maximum power consumption shown above (Watts) is consumed on units running continuously, not taking into account any heat recovery saving and based on SAP Appendix Q testing. 11
12 NUAIRE S MVHR Sap Appendix Q Test Results MRXBOX95AB-WM1 MRXBOX95-WM1 Application Specific Fan Power (W/l/s) Heat Exchange Efficiency Energy Saving Trust Best Practice Compliant Specific Fan Power (W/l/s) Heat Exchange Efficiency Energy Saving Trust Best Practice Compliant Kitchen + 1 Wet Room % Yes % Yes Kitchen + 2 Wet Room % Yes % Yes General Arrangement SPIGOT LOCATION & DUCTING REFERENCES Spigot mm dia. = Intake air from outside. Spigot mm dia. = Supply air to property. Spigot mm dia. = Extract air from dwelling. Spigot mm dia. = Exhaust air to outside. Mounting Bracket on wall and rear of unit Two removable G2 Filters Condensate Tray 12
13 Extract Supply Fan Fan Run on Trickle Boost Trickle Boost Technical - MRXBOX95(AB)-WM1 DIMENSIONS (MM) Weight - 16kg Front View A Filter Access Side View 288 View from top View from Bottom Condensate take off Power Cable entry Electrical Details Please note: the electrical connection of the unit must be carried out by a qualified electrician. Detail of unit control on front panel. The unit is supplied with a flexible cord for connection to the mains supply. NOTE: This unit must be earthed. The mains power supply cable should be connected to a fixed wiring installation, via a fused isolator, in accordance with current IEE wiring regulations. Extract Fan Supply Fan ELECTRICAL DETAILS: MRXBOX95-WM1 Voltage: 230V 1ph 50Hz Consumption: 75W Amp Fuse rating: 3 Amp Run on Trickle Boost Trickle Boost Tamper proof label following commissioning, includes system status indication. 13
14 NUAIRE S MVHR Wiring - MRXBOX95(AB)-WM1 DIMENSIONS (MM) && WEIGHT UNIT UNIT UNIT SERVING KITCHEN & BATHROOM MAINS 230V 50Hz N L Fuse 2A Light switch (Double Pole) Room light 3 Pole isolator Green/Yellow Blue Brown Black Grey Supply cord from unit Optional summer boost switch Kitchen switch UNIT SERVING KITCHEN & TWO BATHROOMS MAINS 230V 50Hz N L Green/Yellow Blue Brown Supply cord from unit Fuse 2A Light switches (Double Pole) Room lights 3 Pole isolator Black Grey Optional summer boost switch Kitchen switch OPTIONAL SENSORS AND DETECTORS Customise MRXBOX95AB-WM1 for enhanced performance. All supplied with pre-plugged 10m data cable and incorporates status LED. MRXBOX95-PIR (passive infra red) A low voltage sensor, detects movement and activates system. Incorporates overrun timer and timer adjustments. MRXBOX95-HUM A low voltage sensor, activates the system when the RH level is above set point. Incorporates overrun timer and RH setpoint level adjustment. MRXBOX95-RFI If fan failure occurs the audio visual indicator will flash a warning. 14
15 Consultants Specification OPERATION The supply and extract system shall be wall/cupboard mounted in accordance with the specification. The combined supply and extract with heat recovery unit, shall supply filtered fresh air to each of the habitable rooms and vitiated air shall be extracted from all wet areas, e.g. bathroom, en suite, w.c, kitchen, utility rooms etc. The supply air shall be pre-heated by the warm extract air via the integrated counter-flow heat exchanger element. The ventilation unit shall vary its speed and therefore the ventilation rate, as it receives signals from one of the following: Switched live signal from light/remote switches Optional externally interconnected sensors When signals are received, the fan shall alter its speed to adjustable, normal and boost rates. An adjustable run-on facility is integrated into the unit which allows the fans to run-on for between 1 and 60 minutes after the signals have been switched off. The unit shall have the facility to commission the supply and extract fans independently on minimum speed (continuous background ventilation), and boost speed, via inbuilt minimum and maximum speed adjustment. The fans shall have infinitely variable speed control. CONTROL OPTIONS All versions shall have the following functions integrally mounted within the fan unit on a purpose made PCB, all such components pre-wired and factory fitted by the manufacturer: - Independent control of background supply and extract flow rates. Independent control of boost speed supply and extract flow rates. Integral heat exchanger frost protection. Integral adjustable run on timer. Fan failure indication. Integral S/L terminal for boost from remote switch, e.g. light switch. Indication and controls The unit shall have clear LED visual indication for maintenance, servicing and operation mode, i.e. summer bypass, frost protection. INTEGRAL AUTOMATIC SUMMER BYPASS MRXBOX95AB-WM1 The bypass damper shall open automatically via a wax actuator, allowing the air to bypass the heat exchanger to deliver fresh filtered air during the warmer months. UNIT SPECIFICATION The unit shall be fully insulated providing excellent thermal and acoustic characteristics and shall be complete with a multi plate counter flow high efficiency heat exchanger block, with a thermal efficiency of up to 95%. The heat exchanger shall be protected by G2 grade filters on fresh air inlet and system extract. The heat exchanger and filters shall be accessible via the front access panel, enabling quick and easy maintenance. The unit shall have low energy, high efficiency d.c. fan/motor assemblies with sealed for life bearings, the impellers shall be backward curved centrifugal type. The motors shall be suitable of an ambient temperature of 40ºC. The unit shall be supplied complete with an insulated condensate drip tray and 21.5mm drain connection. The unit shall be suitable for 125mm circular ducting. Note: The unit is also available in opposite handed format, refer to spigot configuration for set up. The breakout noise level and power requirements shall be as detailed by the unit manufacturer and in accordance with the ventilation equipment schedule. Units shall be MRXBOX95-WM1 or MRXBOX95AB-WM1 as manufactured by Nuaire and shall be listed on the Sap Appendix Q database. 15
16 NUAIRE S MVHR MRXBOX95AB-WM1-OH (with automatic summer bypass) & MRXBOX95-WM1-OH The MRXBOXB95AB-WM1-OH has been designed with automatic summer bypass and the facility to commission the supply and extract fans independently on both minimum and maximum speeds, in addition to the features you will find on the standard MRXBOX95-WM1-OH. Sensors for the MRXBOX95(AB) WM1-OH include: MRXBOX95-PIR (Passive Infra Red) - A low voltage sensor, detects movement and activates system. Incorporates overrun timer and timer adjustments. MRXBOX95-HUM - A low voltage sensor, activates the system when the RH level is above set point. Incorporates overrun timer and RH set point level adjustment. Both the MRXBOXBOX95AB-WM1-OH and MRXBOX95-WM1-OH are designed to provide optimised balanced (supply and extract) mechanical ventilation with heat recovery. Tempered air is delivered into living areas whilst extracting moisture laden air from wet areas, creating comfortable well - ventilated homes. The unit uses the latest generation of low voltage DC fans and motors, counter flow heat exchanger and easy accessible controls. The heat exchanger block can recover up to 95% of the normally wasted heat. The two independent fans have full speed control for background and boost ventilation rates as well as a run-on timer facility and adjacent smoke detectors. Both units are listed on the Product Characteristics Database. MRXBOX95-RFI - If fan failure occurs, the audio visual indicator will flash a warning. Typical Installation INSTALLATION FEATURES Filter being removed Filter cover Filter Code MVHR-WM1-FILTERKIT 16
17 Performance - MRXBOX95(AB)-WM1-OH CODE DESCRIPTION MRXBOX95-WM1-OH Fan Static Pressure (Pa) Multi-room supply and extract heat recovery 2. Product range 3. Efficiency 4. Wall/cupboard application 5. Medium duty 6. Opposite hand MRXBOX95 AB -WM1-OH Air Volume Flow Rate (l/s) Electrical & Sound 1. Multi-room supply and extract heat recovery 2. Product range 3. Efficiency 4. Automatic Summer Bypass 5. Wall/cupboard application 6. Medium duty 7. Opposite hand Maximum power consumption Sound Power Levels db re 1pW Curve (Watts) K 2K 4K 8K Curve 1 71 Open inlet Open Outlet Breakout Open inlet Open Outlet Breakout Open inlet Open Outlet Breakout Open inlet Open Outlet Breakout Open inlet <10 Open Outlet Breakout The maximum power consumption shown above (Watts) is consumed on units running continuously, not taking into account any heat recovery saving and based on SAP Appendix Q testing. 17
18 NUAIRE S MVHR Sap Appendix Q Test Results MRXBOX95AB-WM1-OH MRXBOX95-WM1-OH Application Specific Fan Power (W/l/s) Heat Exchange Efficiency Energy Saving Trust Best Practice Compliant Specific Fan Power (W/l/s) Heat Exchange Efficiency Energy Saving Trust Best Practice Compliant Kitchen + 1 Wet Room % Yes % Yes Kitchen + 2 Wet Room % Yes % Yes General Arrangement SPIGOT LOCATION & DUCTING REFERENCES Spigot mm dia. = Intake air from outside. Spigot mm dia. = Supply air to property. Spigot mm dia. = Extract air from dwelling. Spigot mm dia. = Exhaust air to outside. Mounting Bracket on wall and rear of unit Two removable G2 Filters Condensate Tray 18
19 Extract Supply Fan Fan Run on Trickle Boost Trickle Boost Technical - MRXBOX95(AB)-WM1-OH DIMENSIONS (MM) Weight - 16kg Front View A Filter Access Side View 288 View from top View from Bottom Condensate take off Power Cable entry Electrical Details Please note: the electrical connection of the unit must be carried out by a qualified electrician. Detail of unit control on front panel. The unit is supplied with a flexible cord for connection to the mains supply. NOTE: This unit must be earthed. The mains power supply cable should be connected to a fixed wiring installation, via a fused isolator, in accordance with current IEE wiring regulations. Extract Fan Supply Fan ELECTRICAL DETAILS: MRXBOX95-WM1-OH Voltage: 230V 1ph 50Hz Consumption: 75W Amp Fuse rating: 3 Amp Run on Trickle Boost Trickle Boost Tamper proof label following commissioning, includes system status indication. 19
20 NUAIRE S MVHR Wiring - MRXBOX95(AB)-WM1-OH DIMENSIONS (MM) && WEIGHT UNIT UNIT UNIT SERVING KITCHEN & BATHROOM MAINS 230V 50Hz N L Fuse 2A Light switch (Double Pole) Room light 3 Pole isolator Green/Yellow Blue Brown Black Grey Supply cord from unit Optional summer boost switch Kitchen switch UNIT SERVING KITCHEN & TWO BATHROOMS MAINS 230V 50Hz N L Green/Yellow Blue Brown Supply cord from unit Fuse 2A Light switches (Double Pole) Room lights 3 Pole isolator Black Grey Optional summer boost switch Kitchen switch OPTIONAL SENSORS AND DETECTORS Customise MRXBOX95AB-WM1-OH for enhanced performance. All supplied with pre-plugged 10m data cable and incorporates status LED. MRXBOX95-PIR (passive infra red) A low voltage sensor, detects movement and activates system. Incorporates overrun timer and timer adjustments. MRXBOX95-HUM A low voltage sensor, activates the system when the RH level is above set point. Incorporates overrun timer and RH setpoint level adjustment. MRXBOX95-RFI If fan failure occurs the audio visual indicator will flash a warning. 20
21 Consultants Specification OPERATION The supply and extract system shall be wall/cupboard mounted in accordance with the specification. The combined supply and extract with heat recovery unit, shall supply filtered fresh air to each of the habitable rooms and vitiated air shall be extracted from all wet areas, e.g. bathroom, en suite, w.c, kitchen, utility rooms etc. The supply air shall be pre-heated by the warm extract air via the integrated counter-flow heat exchanger element. The ventilation unit shall vary its speed and therefore the ventilation rate, as it receives signals from one of the following: Switched live signal from light/remote switches Optional externally interconnected sensors When signals are received, the fan shall alter its speed to adjustable, normal and boost rates. An adjustable run-on facility is integrated into the unit which allows the fans to run-on for between 1 and 60 minutes after the signals have been switched off. The unit shall have the facility to commission the supply and extract fans independently on minimum speed (continuous background ventilation), and boost speed, via inbuilt minimum and maximum speed adjustment. The fans shall have infinitely variable speed control. CONTROL OPTIONS All versions shall have the following functions integrally mounted within the fan unit on a purpose made PCB, all such components pre-wired and factory fitted by the manufacturer: - Independent control of background supply and extract flow rates. Independent control of boost speed supply and extract flow rates. Integral heat exchanger frost protection. Integral adjustable run on timer. Fan failure indication. Integral S/L terminal for boost from remote switch, e.g. light switch. Indication and controls The unit shall have clear LED visual indication for maintenance, servicing and operation mode, i.e. summer bypass, frost protection. INTEGRAL AUTOMATIC SUMMER BYPASS MRXBOX95AB-WM1-OH The bypass damper shall open automatically via a wax actuator, allowing the air to bypass the heat exchanger to deliver fresh filtered air during the warmer months. UNIT SPECIFICATION The unit shall be fully insulated providing excellent thermal and acoustic characteristics and shall be complete with a multi plate counter flow high efficiency heat exchanger block, with a thermal efficiency of up to 95%. The heat exchanger shall be protected by G2 grade filters on fresh air inlet and system extract. The heat exchanger and filters shall be accessible via the front access panel, enabling quick and easy maintenance. The unit shall have low energy, high efficiency d.c. fan/motor assemblies with sealed for life bearings, the impellers shall be backward curved centrifugal type. The motors shall be suitable of an ambient temperature of 40ºC. The unit shall be supplied complete with an insulated condensate drip tray and 21.5mm drain connection. The unit shall be suitable for 125mm circular ducting. Note: The unit is also available in standard format, refer to spigot configuration for set up. The breakout noise level and power requirements shall be as detailed by the unit manufacturer and in accordance with the ventilation equipment schedule. Units shall be MRXBOX95-WM1-OH or MRXBOX95AB-WM1-OH as manufactured by Nuaire and shall be listed on the Sap Appendix Q database. 21
22 NUAIRE S MVHR MRXBOX95AB-WM2 (with automatic summer bypass) & MRXBOX95-WM2 The MRXBOX95AB-WM2 has been designed with automatic summer bypass and the facility to commission the supply and extract fans independently on both minimum and maximum speeds. Both the MRXBOX95AB-WM2 and MRXBOX95-WM2 are designed to provide optimised balanced (supply and extract) mechanical ventilation with heat recovery. Tempered air is delivered into living areas whilst extracting moisture laden air from wet areas, creating comfortable well ventilated homes. The unit has the facility to commission the supply and extract fans independently on both minimum and maximum speeds. The heat exchanger block can recover up to 90% of the normally wasted heat. Both units are listed on the Product Characteristics Database. Typical Installation INSTALLATION FEATURES Filter being removed Filter cover Filter Code MVHR-WM2-FILTERKIT 22
23 Performance - MRXBOX95(AB)-WM2 Fan Static Pressure (Pa) Air Volume Flow Rate (l/s) ISO AMCA 300 V Type D Air Density 1.2 kg/m 2 CODE DESCRIPTION MRXBOX95-WM Multi-room supply and extract heat recovery 2. Product range 3. Efficiency 4. Wall/cupboard application 5. Medium duty MRXBOX95AB-WM Multi-room supply and extract heat recovery 2. Product range 3. Efficiency 4. Automatic Summer Bypass 5. Wall/cupboard application 6. Medium duty Electrical & Sound Maximum power consumption Sound Power Levels db re 1pW Curve (Watts) K 2K 4K 8K Curve Open inlet Open Outlet Breakout Open inlet Open Outlet Breakout Open inlet <16 26 Open Outlet Breakout <16 < Open inlet <16 <16 18 Open Outlet Breakout <16 < Open inlet <16 <16 <16 <16 Open Outlet <16 24 Breakout <16 <16 18 The maximum power consumption shown above (Watts) is consumed on units running continuously, not taking into account any heat recovery saving and based on SAP Appendix Q testing. 23
24 NUAIRE S MVHR Sap Appendix Q Test Results MRXBOX95AB-WM2 MRXBOX95-WM2 Application Specific Fan Power (W/l/s) Heat Exchange Efficiency Energy Saving Trust Best Practice Compliant Specific Fan Power (W/l/s) Heat Exchange Efficiency Energy Saving Trust Best Practice Compliant Kitchen + 1 Wet Room % Yes % Yes Kitchen + 2 Wet Room % Yes % Yes Kitchen + 3 Wet Room % Yes % Yes Kitchen + 4 Wet Room % Yes % Yes Kitchen + 5 Wet Room % Yes Yes General Arrangement SPIGOT LOCATION & DUCTING REFERENCES Spigot mm dia. = Intake air from outside. Spigot mm dia. = Supply air to property. Spigot mm dia. = Extract air from dwelling. Spigot mm dia. = Exhaust air to outside. Mounting Bracket on wall and rear of unit Two removable G2 Filters Condensate Tray 24
25 Extract Supply Fan Fan Run on Trickle Boost Trickle Boost Technical - MRXBOX95(AB)-WM2 DIMENSIONS (MM) Weight - 21kg Front View Side View Mounting View from top bracket Spigots 4x 125mm dia Detail of unit control on front panel. Extract Fan Supply Fan Run on Trickle Boost Trickle Boost Tamper proof label following commissioning, includes system status indication. Electrical Details Please note: the electrical connection of the unit must be carried out by a qualified electrician. The unit is supplied with a flexible cord for connection to the mains supply. NOTE: This unit must be earthed. MRXBOX-VSC CONTROL SCREEN COMPATIBLE WITH THIS UNIT The mains power supply cable should be connected to a fixed wiring installation, via a fused isolator, in accordance with current IEE wiring regulations. ELECTRICAL DETAILS: MRXBOX95-WM2 Voltage: 230V 1ph 50Hz Consumption: WM2-1.3 Amp Fuse rating: 3 Amp 25
26 NUAIRE S MVHR Wiring - MRXBOX95(AB)-WM2 DIMENSIONS (MM) & WEIGHT UNIT UNIT SERVING KITCHEN & BATHROOM MAINS 230V 50Hz N L Fuse 2A Light switch (Double Pole) Room light 3 Pole isolator Green/Yellow Blue Brown Black Grey Supply cord from unit Optional summer boost switch Kitchen switch UNIT SERVING KITCHEN & TWO BATHROOMS MAINS 230V 50Hz N L Green/Yellow Blue Brown Supply cord from unit Fuse 2A Light switches (Double Pole) Room lights 3 Pole isolator Black Grey Optional summer boost switch Kitchen switch 26
27 Consultants Specification OPERATION The supply and extract system shall be positioned as indicated on the drawings and shall be in accordance with the particular fan schedule in the specification. The combined supply and extract with heat recovery unit, shall supply filtered fresh air to each of the habitable rooms and vitiated air shall be extracted from all wet areas, e.g. bathroom, en suite, w.c, kitchen, utility rooms etc. The supply air shall be pre-heated by the warm extract air via the integrated counter-flow heat exchanger element. The extracted air shall also be filtered before it reaches the heat exchanger block. The ventilation unit shall vary its speed and therefore the ventilation rate, as it receives signals from one of the following: Switched live signal from light/remote switches When signals are received, the fan shall alter its speed to adjustable, normal and boost rates. An adjustable run-on facility is integrated into the unit which allows the fans to run-on for between 1 and 60 minutes after the signals have been switched off. The unit shall have the facility to commission the supply and extract fans independently on minimum speed (continuous background ventilation), and boost speed, via inbuilt minimum and maximum speed adjustment. The fans shall have infinitely variable speed control. UNIT SPECIFICATION The unit shall be fully insulated providing excellent thermal and acoustic characteristics and shall be complete with a multi plate counter flow high efficiency heat exchanger block, with a thermal efficiency of up to 90%. The heat exchanger shall be protected by G3 grade filters on fresh air inlet and system extract. The heat exchanger and filters shall be accessible via the front access panel, enabling quick and easy maintenance. The unit shall have low energy, high efficiency EC fan/motor assemblies with sealed for life bearings, the impellers shall be backward curved centrifugal type. The motors shall be suitable of an ambient temperature of 40ºC. The unit shall be supplied complete with an insulated condensate drip tray and 21.5mm drain connection. The unit shall be suitable for 125mm circular ducting. Note: The unit is also available in opposite handed format, refer to spigot configuration for set up. The breakout noise level and power requirements shall be as detailed by the unit manufacturer and in accordance with the ventilation equipment schedule. Units shall be MRXBOX95-WM2 or MRXBOX95AB-WM2 as manufactured by Nuaire and shall be listed on the SAP Appendix Q database. CONTROL OPTIONS All versions shall have the following functions integrally mounted within the fan unit on a purpose made PCB, all such components pre-wired and factory fitted by the manufacturer: - Independent control of background supply and extract flow rates. Independent control of boost speed supply and extract flow rates. Integral heat exchanger frost protection. Fan failure indication. Integral S/L terminal for boost from remote switch, e.g. light switch. Additional S/L terminal for 100% boost speed from remote switch, e.g. plate switch Discreet daily run monitor. Remote fail indicator (part number MRXBOX95LH-RFI) Indication and controls The unit shall have clear LED visual indication for maintenance, servicing and operation mode, i.e. summer bypass, frost protection. INTEGRAL AUTOMATIC SUMMER BYPASS MRXBOX95AB-WM2 The bypass damper shall open automatically via a wax actuator, allowing the air to bypass the heat exchanger to deliver fresh filtered air during the warmer months. Integral Humidity Sensor The integral humidity sensor incorporated within the extract fan chamber will automatically boost both the extract and supply fan, to the commissioned boost speed, when the humidity level exceeds that set by the front panel mounted adjustment potentiometer. MRXBOX-VSC (VISUAL SYSTEM CONTROLLER) The MRXBOX-VSC is compatible with the Nuaire MRXBOX95(AB)-WM2 heat recovery units and can be purchased separately. The controller comes complete with commissioning and end user functions. The display will be a 3.2 LCD display and will remain on standby until such time the screen is touched. The initial display will show the MVHR system status as listed below: Current Fan Speed Current indoor/outside temperature (MRXBOX95AB units only) Indicate when the summer bypass is activated Indicate when frost protection is activated Indicate when the filters require cleaning/changing. 27
28 NUAIRE S MVHR MRXBOX95AB-WM2-OH (with automatic summer bypass) & MRXBOX95-WM2-OH The MRXBOX95AB-WM2-OH has been designed with automatic summer bypass and the facility to commission the supply and extract fans independently on both minimum and maximum speeds. Both the MRXBOX95AB-WM2-OH and MRXBOX95-WM2-OH are designed to provide optimised balanced (supply and extract) mechanical ventilation with heat recovery. Tempered air is delivered into living areas whilst extracting moisture laden air from wet areas, creating comfortable well ventilated homes. The unit has the facility to commission the supply and extract fans independently on both minimum and maximum speeds. The heat exchanger block can recover up to 90% of the normally wasted heat. Both units are listed on the Product Characteristics Database. Typical Installation INSTALLATION FEATURES Filter being removed Filter cover Filter Code MVHR-WM2-FILTERKIT 28
29 Performance - MRXBOX95(AB)-WM2-OH Fan Static Pressure (Pa) Electrical & Sound Air Volume Flow Rate (l/s) ISO AMCA 300 V Type D Air Density 1.2 kg/m 2 CODE DESCRIPTION MRXBOX95-WM2-OH Multi-room supply and extract heat recovery 2. Product range 3. Efficiency 4. Wall/cupboard application 5. Medium duty 6. Opposite hand MRXBOX95AB-WM2-OH Multi-room supply and extract heat recovery 2. Product range 3. Efficiency 4. Automatic Summer Bypass 5. Wall/cupboard application 6. Medium duty 7. Opposite hand Maximum power consumption Sound Power Levels db re 1pW Curve (Watts) K 2K 4K 8K Curve Open inlet Open Outlet Breakout Open inlet Open Outlet Breakout Open inlet <16 26 Open Outlet Breakout <16 < Open inlet <16 <16 18 Open Outlet Breakout <16 < Open inlet <16 <16 <16 <16 Open Outlet <16 24 Breakout <16 <16 18 The maximum power consumption shown above (Watts) is consumed on units running continuously, not taking into account any heat recovery saving and based on SAP Appendix Q testing. 29
30 NUAIRE S MVHR Sap Appendix Q Test Results MRXBOX95AB-WM2-OH MRXBOX95-WM2-OH Application Specific Fan Power (W/l/s) Heat Exchange Efficiency Energy Saving Trust Best Practice Compliant Specific Fan Power (W/l/s) Heat Exchange Efficiency Energy Saving Trust Best Practice Compliant Kitchen + 1 Wet Room % Yes % Yes Kitchen + 2 Wet Room % Yes % Yes Kitchen + 3 Wet Room % Yes % Yes Kitchen + 4 Wet Room % Yes % Yes Kitchen + 5 Wet Room % Yes Yes General Arrangement SPIGOT LOCATION & DUCTING REFERENCES Spigot mm dia. = Intake air from outside. Spigot mm dia. = Supply air to property. Spigot mm dia. = Extract air from dwelling. Spigot mm dia. = Exhaust air to outside. Mounting Bracket on wall and rear of unit Two removable G2 Filters Condensate Tray 30
31 Extract Supply Fan Fan Run on Trickle Boost Trickle Boost Technical - MRXBOX95(AB)-WM2-OH DIMENSIONS (MM) Weight - 21kg Front View Side View Mounting View from top bracket Spigots 4x 125mm dia Detail of unit control on front panel. Extract Fan Supply Fan Run on Trickle Boost Trickle Boost Tamper proof label following commissioning, includes system status indication. Electrical Details Please note: the electrical connection of the unit must be carried out by a qualified electrician. The unit is supplied with a flexible cord for connection to the mains supply. NOTE: This unit must be earthed. MRXBOX-VSC CONTROL SCREEN COMPATIBLE WITH THIS UNIT The mains power supply cable should be connected to a fixed wiring installation, via a fused isolator, in accordance with current IEE wiring regulations. ELECTRICAL DETAILS: MRXBOX95-WM2-OH Voltage: 230V 1ph 50Hz Consumption: WM2-1.3 Amp Fuse rating: 3 Amp 31
32 NUAIRE S MVHR Wiring - MRXBOX95(AB)-WM2-OH DIMENSIONS (MM) & WEIGHT UNIT UNIT SERVING KITCHEN & BATHROOM MAINS 230V 50Hz N L Fuse 2A Light switch (Double Pole) Room light 3 Pole isolator Green/Yellow Blue Brown Black Grey Supply cord from unit Optional summer boost switch Kitchen switch UNIT SERVING KITCHEN & TWO BATHROOMS MAINS 230V 50Hz N L Green/Yellow Blue Brown Supply cord from unit Fuse 2A Light switches (Double Pole) Room lights 3 Pole isolator Black Grey Optional summer boost switch Kitchen switch 32
33 Consultants Specification OPERATION The supply and extract system shall be positioned as indicated on the drawings and shall be in accordance with the particular fan schedule in the specification. The combined supply and extract with heat recovery unit, shall supply filtered fresh air to each of the habitable rooms and vitiated air shall be extracted from all wet areas, e.g. bathroom, en suite, w.c, kitchen, utility rooms etc. The supply air shall be pre-heated by the warm extract air via the integrated counter-flow heat exchanger element. The extracted air shall also be filtered before it reaches the heat exchanger block. The ventilation unit shall vary its speed and therefore the ventilation rate, as it receives signals from one of the following: Switched live signal from light/remote switches When signals are received, the fan shall alter its speed to adjustable, normal and boost rates. An adjustable run-on facility is integrated into the unit which allows the fans to run-on for between 1 and 60 minutes after the signals have been switched off. The unit shall have the facility to commission the supply and extract fans independently on minimum speed (continuous background ventilation), and boost speed, via inbuilt minimum and maximum speed adjustment. The fans shall have infinitely variable speed control. UNIT SPECIFICATION The unit shall be fully insulated providing excellent thermal and acoustic characteristics and shall be complete with a multi plate counter flow high efficiency heat exchanger block, with a thermal efficiency of up to 90%. The heat exchanger shall be protected by G3 grade filters on fresh air inlet and system extract. The heat exchanger and filters shall be accessible via the front access panel, enabling quick and easy maintenance. The unit shall have low energy, high efficiency EC fan/motor assemblies with sealed for life bearings, the impellers shall be backward curved centrifugal type. The motors shall be suitable of an ambient temperature of 40ºC. The unit shall be supplied complete with an insulated condensate drip tray and 21.5mm drain connection. The unit shall be suitable for 125mm circular ducting. Note: The unit is also available in standard format, refer to spigot configuration for set up. The breakout noise level and power requirements shall be as detailed by the unit manufacturer and in accordance with the ventilation equipment schedule. Units shall be MRXBOX95-WM2-OH or MRXBOX95AB-WM2-OH as manufactured by Nuaire and shall be listed on the SAP Appendix Q database. CONTROL OPTIONS All versions shall have the following functions integrally mounted within the fan unit on a purpose made PCB, all such components pre-wired and factory fitted by the manufacturer: - Independent control of background supply and extract flow rates. Independent control of boost speed supply and extract flow rates. Integral heat exchanger frost protection. Fan failure indication. Integral S/L terminal for boost from remote switch, e.g. light switch. Additional S/L terminal for 100% boost speed from remote switch, e.g. plate switch Discreet daily run monitor. Remote fail indicator (part number MRXBOX95LH-RFI) Indication and controls The unit shall have clear LED visual indication for maintenance, servicing and operation mode, i.e. summer bypass, frost protection. INTEGRAL AUTOMATIC SUMMER BYPASS MRXBOX95AB-WM2-OH The bypass damper shall open automatically via a wax actuator, allowing the air to bypass the heat exchanger to deliver fresh filtered air during the warmer months. Integral Humidity Sensor The integral humidity sensor incorporated within the extract fan chamber will automatically boost both the extract and supply fan, to the commissioned boost speed, when the humidity level exceeds that set by the front panel mounted adjustment potentiometer. MRXBOX-VSC (VISUAL SYSTEM CONTROLLER) The MRXBOX-VSC is compatible with the Nuaire MRXBOX95(AB)- WM2-OH heat recovery units and can be purchased separately. The controller comes complete with commissioning and end user functions. The display will be a 3.2 LCD display and will remain on standby until such time the screen is touched. The initial display will show the MVHR system status as listed below: Current Fan Speed Current indoor/outside temperature (MRXBOX95AB-OH units only) Indicate when the summer bypass is activated Indicate when frost protection is activated Indicate when the filters require cleaning/changing. 33
34 NUAIRE S MVHR MRXBOX95AB-WH1 (with automatic summer bypass) & MRXBOX95-WH1 The MRXBOXB95AB-WH1 has been designed with automatic summer bypass and the facility to commission the supply and extract fans independently on both minimum and maximum speeds. Both the MRXBOX95AB-WH1 and MRXBOX95-WH1 are designed to provide optimised balanced (supply and extract) mechanical ventilation with heat recovery. Tempered air is delivered into living areas whilst extracting moisture laden air from wet areas, creating comfortable well ventilated homes. The unit has the facility to commission the supply and extract fans independently on both minimum and maximum speeds. The heat exchanger block can recover up to 95% of the normally wasted heat. Both units are listed on the Product Characteristics Database. Typical Installation INSTALLATION FEATURES Filter being removed Filter cover Filter Code MVHR-WH1-FILTERKIT 34
35 Performance - MRBOX95(AB)-WH1 500 CODE DESCRIPTION MRXBOX95-WH1 Fan Static Pressure (Pa) Air Volume Flow Rate (l/s) Multi-room supply and extract heat recovery 2. Product range 3. Efficiency 4. Wall/cupboard application 5. High 1 Model MRXBOX95AB-WH Multi-room supply and extract heat recovery 2. Product range 3. Efficiency 4. Automatic Summer Bypass 5. Wall/cupboard application 6. High 1 Model Electrical & Sound Maximum power consumption Sound Power Levels db re 1pW Curve (Watts) K 2K 4K 8K Curve Open inlet <16 31 Open Outlet Breakout < Open inlet <16 30 Open Outlet Breakout < Open inlet <16 29 Open Outlet Breakout < Open inlet <16-25 Open Outlet Breakout <16 < Open inlet <16 <16 22 Open Outlet Breakout <16 < Open inlet <16 <16 <16 <16 Open Outlet <16 27 Breakout <16 <16 <16 <16 19 The maximum power consumption shown above (Watts) is consumed on units running continuously, not taking into account any heat recovery saving and based on SAP Appendix Q testing. 35
squrboxbox heat recovery squrboxbox I technical information
heatrecoveryrange heat recovery squrboxbox I technical information squrboxbox Low depth high performance Only 350mm deep & up to 430l/s, providing the most effective low depth solution. Quietest solution
More informationDuplexvent DV72 EC So light, so slim it fits inside a 600mm cupboard
Duplexvent DV72 EC So light, so slim it fits inside a 600mm cupboard Duplexvent DV72 EC MVHR is designed to provide constant volume ventilation levels to exceed the latest Building Regulations 2010. The
More informationHRU ECO 4. System 4 Continuous Mechanical Supply and Extract Ventilation with Heat Recovery Appendix Q Eligible
HRU ECO 4 System 4 Continuous Mechanical Supply and Extract Ventilation with Heat Recovery Appendix Q Eligible Weight As a result of the unique clamping construction in combination with the plastic/synthetic
More informationMODEL: DV72. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual. Configuration Left Hand Right Hand
9041381- Issue 6 4/11 MODEL: DV72 Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual Commissioning Data: to be completed by the installer Date of installation: Configuration
More informationInstallation and Maintenance
MRXBOX95B-LP1 (Standard Unit) MRXBOX95B-LP1-OH (Opposite Hand Unit) Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Ceiling Void Mounting Installation and Maintenance The EMC Directive
More informationPart 3 Ancillary technologies. Chapter 3.2. Mechanical ventilation with heat recovery
Part 3 Ancillary technologies Chapter CONTENTS SCOPE Clause Page DESIGN Design standards D1 1 Statutory requirements D2 1 System design D3 1 Building integration D4 2 Noise D5 2 Access and controls D6
More informationIMPROVING INDOOR AIR QUALITY IN NEW HOMES. MECHANICAL EXTRACT VENTILATION (MEV & dmev)
IMPROVIG IDOOR AIR QUAITY I EW HOMES MECHAICA EXTRACT VETIATIO (MEV & dmev) UAIRE S PEDIGREE Proud to Build British uaire is a world leader in the design and manufacture of fans and ventilation systems.
More informationZehnder Focus 200. Ventilation device
Ventilation device Use The Zehnder Focus (F) 200 comfort ventilation unit was specially developed for use in demanding residential and commercial buildings. It combines maximum comfort, simple operation
More informationTechnical Bulletin 005(A) Developed with Communities and Local Government
Technical Bulletin 005(A) Developed with Communities and Local Government Title: Gas cookers in internal kitchens - Ventilation requirements as applied to England, Wales, the le of Man and Guernsey Date
More informationMistrale. Fusion Terminal
Mistrale Fusion Terminal PUBLICATION NATURAL VENT. 1 SEPT 2015 Features - Slimline energy efficient ventilation solution - Standard and high capacity terminals provide 128 or 256 L/s capacity - Compliant
More informationNUAIRE VENTILATION SYSTEMS DRIMASTER, DRIMASTER 3S, DRIMASTER 2000 AND DRIMASTER 2000 3S SYSTEMS
NuAire Ltd Western Industrial Estate Caerphilly Mid Glamorgan CF83 1NA Tel: 029 2085 8200 Fax: 029 2085 8300 e-mail: info@nuaire.co.uk website: www.nuaire.co.uk Agrément Certificate 00/3727 Product Sheet
More informationCADB and CADT-D / DI / DC Series
HEAT RECOVERY UNITS CADB and CADT-D / DI / DC Series NEW The CADB, CADT heat recovery range consists of: - Self-supporting casing with extruded aluminium profile structure and beige plastic coated galvanised
More informationNUAIRE VENTILATION SYSTEMS FLATMASTER AND FLATMASTER 2000 SYSTEMS
NuAire Ltd Western Industrial Estate Caerphilly Mid Glamorgan CF83 1NA Tel: 02920 858 200 Fax: 02920 858 300 e-mail: info@nuaire.co.uk website: www.nuaire.co.uk NUAIRE VENTILATION SYSTEMS APPROVAL INSPECTION
More informationAirline. small air handlers and extract fan units. VES Airline part of a complete range of innovative, flexible products from the HVAC experts
Lo w p r o f i l e small air handlers and extract fan units Duties to 0.55m 3 /sec Available with the Electroline fitted control panel Ceiling void friendly - unit heights from 190mm to 350mm Airline VES
More informationRochdale Building Control Guide. Approved Document F Means of ventilation
Rochdale Building Control Guide Approved Document F Means of ventilation Coming into effect 1 st October 2010 As we build homes that are more airtight it is increasingly becoming important to ensure that
More informationDIMENSIONS SELV MODELS
25 CURZON - 1mm CENTRIFUGL FNS DIMENSIONS B Ø C D E Measured in mm : 216 B : 195 C : 5 D : 52 E : 98 Ø* * : 8/1 * (8mm without adaptor 1mm with adaptor) CURZON - 1mm CENTRIFUGL FNS 14 12 1 8 6 4 2 14 12
More informationUSER S MANUAL HSC-24A
AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL
More informationThe space saving solution.
10 KICKSPACE KICKSPACE. Over 70% of people think that they would benefit from additional kitchen space (ICM Research 2012) Kitchen kindly supplied by Second Nature kitchens - www.sncollection.co.uk The
More informationHRU ECO 4 Technical Guide
HRU ECO 4 Technical Guide System 4 Continuous Mechanical Supply and Extract Ventilation with Heat Recovery Appendix Q Eligible Climate for life. Technical Guide for a Climate for Life The Itho Group was
More informationEnergy Efficiency HOSPITALITY. www.energia.ie
Energy Efficiency HOSPITALITY www.energia.ie Your chance to reduce your business energy usage by as much as 20%! 20% is a significant figure and reducing your energy bill by this amount could make a real
More information8W! SILENT-100 Series. 26,5 db BATHROOM EXTRACT FANS. Bathroom and toilet extract fans SILENT-100. Low noise! Water protected! Energy efficient!
Bathroom and toilet extract fans SILENT-100 BATHROOM EXTRACT FANS SILENT-100 Series SILVER versions The SILENT-100 CZ and CRZ can be supplied Range of axial extractors with airflow rates of approx. 95
More informationFrequently Asked Questions. Air Top Diesel Heaters. 2000STC, Evo 40 & Evo 55
Frequently Asked Questions Air Top Diesel Heaters 2000STC, Evo 40 & Evo 55 Question 1 What power outputs are the heaters available in? There are 3 models 2kW, 4kW and 5.5kW Question 2 What voltage are
More informationabout your house How to Get the Ventilation That You Need in Your House Figure 1 Infiltration and exfiltration of air in a house
about your house CE 64 How to Get the Ventilation That You Need in Your House Canadian houses are relatively airtight, and have been for years. The old farmhouses where people lived several generations
More informationRKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features
RKE Heat recovery unit from 200 to 6800 m 3 /h General features RKE heat recovery units are suitable for residential and commercial applications and offer a real energy saving in forced ventilation plants,
More informationLUCCI AIRFUSION QUEST II CEILING FAN
LUCCI AIRFUSION QUEST II CEILING FAN WITH IR REMOTE INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION. V1.0 QUEST II IR
More informationInstallation, operation and maintenance manual TX 35A
Installation, operation and maintenance manual TX 35A Rev.10 may 2012 Page 1 of 18 1.0.0 Table of contents INSTALLATION, OPERATION AND MAINTENANCE MANUAL...1 1.0.0 TABLE OF CONTENTS...2 2.0.0 ILLUSTRATIONS...2
More informationUSER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting
More informationFire. The Fire Installers Mate. A guide to fire alarm systems design
Fire The Fire Installers Mate A guide to fire alarm systems design BS 5839 Part 1:2002 A guide to BS 5839 Part 1:2002 Disclaimer This booklet is not intended to be a comprehensive guide to all aspects
More informationCE6500 Energy Recovery Ventilator
ADVANCED COMMERCIAL Energy Recovery Ventilator PRODUCT SPECIFICATIONS & TECHNICAL DATA Features NOMINAL CAPACITY 5500-7000 CFM CASING Double-wall cabinet White exterior paint, -gauge galvanized steel -gauge
More informationSolar air collectors for industry and larger halls S Ø. Efficient dehumidification and air heating for free...
Solar air collectors for industry and larger halls N S Ø Efficient dehumidification and air heating for free... This booklet contains information about SolarVenti Industrial air solar system. The system
More informationHow To Make Your House Breathe
RENEWABLES VENTILATION UNITS Nothing lost plenty of healthy fresh air gained Innovative ventilation units that offer healthy indoor air and significantly lower energy bills 04 2015 STIEBEL ELTRON is full
More informationPlease read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan
Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan TABLE OF CONTENTS INTRODUCTION 2 IMPORTANT SAFEGUARDS...2 PACKAGE CONTAINS..2 NAMES OF PARTS.3
More informationUnder sill units. Type FSL-B-ZAS
.1 X X testregistrierung Under sill units Type, heat recovery Centrifugal fan Adaptive heat recovery damper HYGIENISCH GETESTET V DI 022 Tested to VDI 022 Secondary air unit for supply air and extract
More informationRRV934. Multi-controller. Synco living
s 2 709 Synco living Multi-controller RRV934 RF-based multi-controller For precontrol of up to 2 room groups For control of ventilation plant with up to 3 stages RF communication based on KNX standard
More informationECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
More informationMeaco 30L and Meaco 40L dehumidifier instruction manual
Meaco 30L and Meaco 40L dehumidifier instruction manual Please read this instruction manual before using the dehumidifier and keep safe for future reference SAFETY INSTRUCTIONS PLEASE READ ALL INSTRUCTIONS
More informationFlexit air handling unit K2 R
Flexit air handling unit K2 R with integrated kitchen hood PATENTED The quietest on the market Modern design Energy-efficient Installation in the kitchen A FOR A HEALTHY ENVIRONMENT Requirement-controlled
More informationHitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE
Hitachi Air Conditioning Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE Contents Page 04 Product Range 08-09 RAC Summit Wall Mounted 10 RAC Shirokuma Wall mounted 11 RAC S Series - Wall
More informationIMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.
THERMAWAVE CERAMIC HEATER Model HZ-850 Series Model HZ-860 Series IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER. Warning Failure to
More informationRapide Inline Ceiling Extractor Fan, White Fascia 41800040590. Rapide Inline Ceiling Extractor Fan, Chrome Fascia 41800040580
Any Queries Call : 08000 23 23 23 Rapide Inline Ceiling Extractor Fan, White Fascia 41800040590 Rapide Inline Ceiling Extractor Fan, White Fascia Illuminated 41800040670 Rapide Inline Ceiling Extractor
More informationREB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16
REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16 Manually Operated Electronic Speed Controller Single Phase For all applications using suitably specified single-phase induction motor fans 1 GENERAL The
More informationNEW! Flexit SL4 R. Air Handling Unit with rotating recovery system Energy-efficient New control system. Patent applied for!
Flexit SL4 R Air Handling Unit with rotating recovery system Energy-efficient New control system NEW! Patent applied for! - Simple settings - Flexible installation - User friendly F O R H E A LT H Y I
More informationGreen Line HRX Ceiling Mounted
Green Line HRX Ceiling Mounted Mechanical Ventilation with Heat Recovery appliance Installation and Operating Instructions Models: HRX-S-C, HRX-B-C, HRX-FP-C, HRX-BFP-C These instructions must be given
More informationsaving energy in comfort Factsheet Recair Enthalpy
saving energy in comfort Factsheet Recair Enthalpy Introduction Enthalpy Exchanger The enthalpy exchanger is able to transfer both sensible heat and latent heat (moisture) from the cooled to the heated
More informationEFA PSBP. Natural Ventilation Strategy. Introduction. 1.1 Relevant legislation. 1.1.1 The Building Regulations 2010
EFA PSBP Natural Ventilation Strategy Introduction The Baseline Designs Project will provide scheme design details for a number of Primary and Secondary School Exemplars. For the purposes of setting a
More informationSWIMMING POOL HEAT PUMP
SWIMMING POOL HEAT PUMP Installation & User Manual Model HP40B HP50B HP65B Hayward Pool Products Canada, Inc. T: 1-888-238-7665 www.haywardpool.ca CONTENT I. Application 4 II. Features 4 III. Technical
More informationEBDSPIR-PRM, EBDSPIR-PRM-IP
Product Guide EBDSPIR-PRM, EBDSPIR-PRM-IP Ceiling PIR presence/absence detector Overview The EBDSPIR-PRM PIR (passive infrared) presence detector provides automatic control of lighting loads with optional
More informationAN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T
Product Instruction Manual Accona AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T Panel heater v16.5/5 Version 3.2 Jan 2015 Contents 1. Important safety points 2. Installation 2.1. Wall mounting
More informationPortable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
More informationDUCTED AIR CONDITIONING SOLUTIONS
DUCTED AIR CONDITIONING SOLUTIONS H I G H E N E R G Y E F F I C I E N C Y B A C K E D B Y A 5 Y E A R F U L L P A R T S & L A B O U R W A R R A N T Y DUCTED RANGE WHY CHOOSE FUJITSU? AUSTRALIA S FAVOURITE
More informationHome Owners Guide HR SERIES HEAT RECOVERY VENTILATOR (HRV) Models HR100V, HR160H & HR220H RESIDENTIAL USE ONLY HR160H & HR220H
HR SERIES HEAT RECOVERY VENTILATOR (HRV) Home Owners Guide Models HR100V, HR160H & HR220H RESIDENTIAL USE ONLY HR100V HR160H & HR220H READ AND SAVE THIS GUIDE PP0924 09/2013 ABOUT S&P S&P is the world's
More informationDéfumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F400-120. advantages.
Défumair XR smoke-extraction fan extraction casing for kitchen at F400-120 Personalisation : - Phonic insulation version by insulated double-skin panels through 25 mm glass wool, class M1. advantages Originally
More information06150 PORVOO, FINLAND Pelican eco ED(D), Pelican eco EDE(D), Pelican eco EDW(D), Pelican eco EDX(D)
Certificate Certified Passive House Component For cool, temperate climates, valid until 31 December 2013 Passive House Institute Dr. Wolfgang Feist 64283 Darmstadt GERMANY Category: Manufacturer: Heat
More informationHeat Pumps for Swimming Pools
Page 1 of 5 Heat Pumps for Swimming Pools This factsheet provides members with invaluable information about heat pumps and their use for heating swimming pool water. There is a consumer factsheet already
More informationTe c h n i c a l G u i d a n c e D o c u m e n t
F Ventilation Building Regulations 2009 Te c h n i c a l G u i d a n c e D o c u m e n t Contents Page Introduction 2 Transitional Arrangements 2 The Guidance 2 Existing Buildings 2 Technical Specifications
More informationFIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval.
Polk School District Specifications for the New Fire Alarm in the Existing Building Eastside Elementary School FIRE ALARM SYSTEM 1.01 SUBMITTALS A. Shop drawings shall be submitted as follows: 1. Manufacturer's
More informationVentilation Solutions Kitchens. fantech
Ventilation Solutions Kitchens 2 Kitchens Today s kitchens have become much more than a place for cooking and food preparation. The kitchen is the heart of the home. It s the center of activity for the
More informationHow To Get A Passive House
Certificate Certified Passive House Component For cool, temperate climates, valid until 31 December 2015 Passive House Institute Dr. Wolfgang Feist 64283 Darmstadt GERMANY Category: Manufacturer: Product
More informationElement D Services Heating, Ventilating, and Air Conditioning
PART 1 - GENERAL 1.01 OVERVIEW A. This section supplements Design Guideline Element D3041 on air handling distribution with specific criteria for projects involving design of a Data Center spaces B. Refer
More informationIMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White
IMPORTANT INSTRUCTIONS & OPERATING MANUAL Houston 50 Inch Electric Wall Mounted Fireplace Black / White Model Number:MFE5050BK Model Number:MFE5050WH Read these instructions carefully before attempting
More information- White Paper - Data Centre Cooling. Best Practice
- White Paper - Data Centre Cooling Best Practice Release 2, April 2008 Contents INTRODUCTION... 3 1. AIR FLOW LEAKAGE... 3 2. PERFORATED TILES: NUMBER AND OPENING FACTOR... 4 3. PERFORATED TILES: WITH
More informationPFT Two stage axial fan The high pressure fan for modern boiler plants
PFT Two stage axial fan The high pressure fan for modern boiler plants Modern boilers equipped with complete flue-gas cleaning systems demand fans for high pressure that can be controlled quickly and accurately
More informationDomestic AC Fans 230V Installation and Operating Guide. eco 230V AC Base Models: icon eco15 72683501 icon15 72591501 icon30 72591601 icon60 72591701
Domestic AC Fans 230V Installation and Operating Guide eco 230V AC Base Models: ico eco15 72683501 ico15 72591501 ico30 72591601 ico60 72591701 ico Domestic Fan 230V Installation, Maintenance and Use ico
More informationLK Electric Boiler - 4,5
LK Electric Boiler -, Design LK Electric Boiler, kw is a wall-mounted electric boiler, intended primarily for low-temperature heating systems, e.g. under floor heating. LK Electric Boiler, kw is delivered
More informationTD-SILENT Series (160 to 1000 models) TD-SILENT Series (1300 and 2000 models) NEW TD-SILENT. In-Line duct fans
IN-LINE MIXED LOW DUT ANS ultra-quiet Series (16 to 1 models) Low profile Mixed-flow fans with sound-absorbent insulation. Extremely quiet. ertified of Approval Noise Abatement Society (TD-35, TD-5, TD-8
More informationAir Conditioner Water Heater - A Product of HotSpot Energy LLC
Air Conditioner Water Heater - A Product of HotSpot Energy LLC PLEASE READ THIS BEFORE YOU INSTALL THE UNIT 1. This air conditioner must be installed and/or repaired by a qualified technician. If you perform
More informationDrayton Digistat +2RF/+3RF
/+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer
More informationOperation and Installation Manual. Max Series
Operation and Installation Manual Max Series Models 95MAX 155MAX 155ECM 155MAXRX 200MAX 200MAXRX MAXTOP 195DCS 300DCS 200ERV 200ERVD New Auto Dehumidistat Function prevents unwanted use of the dehumidistat
More informationInnovent LASER Packaged Fresh Air Conditioning Units
LASER Latent And Sensible Energy Reduction Latent And Sensible Energy Reduction For Outside Air Innovent LASER Packaged Fresh Air Conditioning Units Innovent LASER units provide both sensible and latent
More informationRPV - RP - RA air handling units
APPLICATIONS Heating, ventilation, cooling >> FACTORIES >> WAREHOUSES >> HALLS >> DISTRIBUTION CENTRES >> COMMERCIAL PREMISES >> PLACES OF WORSHIP RPV - RP - RA air handling units www.reznor.eu RPV - RP
More informationEnergy Efficient Air Distribution Systems
(57.7) X from Polypipe Ventilation Energy Efficient Air Distribution Systems VSPweb On-line Planner Providing Duct Systems for: Mechanical Ventilation with Heat Recovery Mechanical Extract Ventilation
More informationCurrent valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
More informationROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.
ROOFTOP - HEAT PUMP UNIT Technical data Applies to Model YNRA R410A This document applies when installing into an air handler or as part of an air handling system. CONTENTS 1. General description... 2
More informationNews! Flexit S20 R. Air Handling Unit. A new generation of Air Handling Units. For a healthy indoor envionment
News! Flexit S20 R Air Handling Unit A new generation of Air Handling Units For a healthy indoor envionment Flexit S20 R Air Handling Unit Flexit is launching a new range of air handling units with capacity
More informationTIG INVERTER INSTRUCTION MANUAL
TIG INVERTER INSTRUCTION MANUAL Contents Warning General Description Block Diagram Main Parameters Circuit Diagram Installation and Operation Caution Maintenance Spare Parts List Troubleshooting 3 4 4
More informationUR...3 URX CF...7 URHE CF...11. Heat recovery unit. Heat recovery unit with refrigerant circuit(442-1947 cfm)
UR...3 Heat recovery unit URX CF...7 Heat recovery unit with refrigerant circuit(442-1947 cfm) URHE CF...11 High efficiency heat recovery unit with refrigeration circuit(588-1942 cfm) UR Heat recovery
More informationELECTRIC CENTRAL HEATING FLOW BOILER
ELECTRIC CENTRAL HEATING FLOW BOILER EKCO.T Used product can t be treated as general communal waste. Disassembled appliance has to be delivered to the collection point of electrical and electronic equipment
More informationPortable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W
MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries
More informationSWIMMING POOL AIR-HANDLING UNITS KU-DB Series
SWIMMING POOL AIR-HANDLING UNITS KU-DB Series ME20 proklima 2 SWIMMING POOL AIR-HANDLING UNITS - KU-DB Series proklima 3 TABLE OF CONTENTS 1 Introduction page 3 2 Features page 4 SWIMMING POOL AREA t =
More informationThe compact unit series
The compact unit series The easy way to maintain a good climate i High, efficient energy recovery with an efficiency of 80 90 % i Energy-saving fan motors utilising EC technology for minimal energy consumption
More information94210E-03 2005-10 L7 X W. User Manual. Air Handling Unit Loft Models with water-based heating
94210E-03 2005-10 FLEXIT L4 X W L7 X W User Manual Air Handling Unit Loft Models with water-based heating Contents 1 Important Safety Instructions... 3 2 Method of Operation - System... 3 3 Operation -
More informationTHERMONET UNDERFLOOR HEATING STANDARD THERMOSTAT KIT STOCK CODE 5260
THERMONET UNDERFLOOR HEATING STANDARD THERMOSTAT KIT STOCK CODE 5260 STANDARD THERMOSTAT KIT 1.0 KIT CONTENTS Parts included: 1 x Thermostat 1 x Wall plate 2 x Mounting box screws 1 x Floor temperature
More informationNewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ELECTRICAL SAFETY This appliance is for indoor use only. Always turn off the unit and unplug
More informationHVAC Checklist - Long Form
HVAC Checklist - Long Form Page 1 of 14 Appendix B discusses HVAC system components in relation to indoor air quality. utside Air Intake Location pen during occupied hours? Unobstructed? Standing water,
More information2014 British Columbia Building Code Changes
District of Houston 250-845-2238 2014 British Columbia Building Code Changes A District of Houston interpretation of the 2014 Building Code Changes for 9.36 & 9.32 The following changes reflect the most
More informationBUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010
Building Control Charnwood Borough Council Southfield Road Loughborough LE11 2TN BUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010 Page 1 of 6 PURPOSE: This Guidance
More informationAIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries
AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries Hot tips and cool ideas to save energy and money! Air conditioning units or systems are often used by foundries
More informationFlexit SPIRIT K2R. Air handling unit with integrated kitchen hood
Flexit SPIRIT K2R Air handling unit with integrated kitchen hood The quietest on the market Modern design Energy-efficient Installation in the kitchen Flexit SPIRIT - a new generation of air handling units
More informationPortable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support
More informationBaxi Combi 130 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Combination Boiler
User s Operating Instructions Baxi Combi 130 HE Gas Fired Wall Mounted Condensing Combination Boiler Please keep these instructions safe. Should you move house, please hand them over to the next occupier.
More informationMechanical and Natural Ventilation
BBSE3006: Air Conditioning and Refrigeration II http://www.hku.hk/bse/bbse3006/ Mechanical and Natural Ventilation Dr. Sam C. M. Hui Department of Mechanical Engineering The University of Hong Kong E-mail:
More informationSMOKE DETECTOR INSTALLATION PROGRAM The Burlington Ordinance Perspective
SMOKE DETECTOR INSTALLATION PROGRAM The Burlington Ordinance Perspective The National Fire Alarm Code, NFPA 72, sets the minimum requirements of performance, selection, use and location of automatic detection
More informationHot Water. Heat pump water heaters. Residential and Commercial R410a
Hot Water Heat pump water heaters Residential and Commercial R410a Heat pump technology Heat Pump Water Heating is a new idea using existing technology and is viewed as the latest generation of water heating
More informationInstallation and Operating Guide LOOVENT eco Centrifugal Fans (SELV versions)
80000156 Issue 1 10/13 Installation and Operating Guide LOOVENT eco Centrifugal Fans (SELV versions) LOOVENT eco T SELV - 72684309 LOOVENT eco HT SELV - 72684310 LOOVENT eco dmev T SELV - 72684312 LOOVENT
More information1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None
1-Way Chilled Water Cassettes KCO 60, 90 & 120 Technical Brochure TM KCO-W.1GB Date : November 2005 Supersedes : None General Features Control valve (optional) Air vent In-tube electric heating elements
More informationAIR-CONDITIONER SPLIT TYPE
FILE NO. A08-016 SERVICE MANUAL AIR-CONDITIONER SPLIT TYPE RAS-M10PKVP-E, RAS-M13PKVP-E, RAS-M16PKVP-E, RAS-M18PKVP-E / RAS-M10PKVP-ND, RAS-M13PKVP-ND, RAS-M16PKVP-ND, RAS-M18PKVP-ND / RAS-3M26GAV-E1,
More informationDC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.
1100 & 1400 Energy Controllers Satchwell 1100 & 1400 for energy-efficient temperature control in smaller buildings. 02 1100 & 1400 Energy Controllers Features he 1100 and 1400 Energy Controllers are self-configuring
More informationBring the fresh in. Dedicated Outside Air Systems
Bring the fresh in. Dedicated Outside Air Systems The inside story on outside air. On average, we breathe in 3,400 gallons of air each day. Ambient indoor air pollution is a major problem, affecting health
More informationR22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power
R22. K Control. Indoor Unit. Nomenclature. PL H 3 G K H B Compatibility Unit style Heat Pump Horse Power Control Boost Heaters R22. K Control. Outdoor Unit. Nomenclature. PU H 3 Y K A Compatibility Outdoor
More informationSolar Homes Catch the Sun. Are you planning a new house? Discover how you can apply solar architecture principles to:
PASSIVE Solar Design Solar Homes Catch the Sun Are you planning a new house? Discover how you can apply solar architecture principles to: keep your heating bills to a minimum enjoy the comfort of a warm
More information