1 A Power Relay for a Variety of Purposes with Various Models ROHS compliant Conforms to EN 680-, UL08, CSA22.2, SEV, SEMKO. Meets EN6033- requirements for household products. Clearance and creepage distance: 8 mm/8 m. Models with CTI material available. High-sensitivity (360 mw) and high-capacity (6 A) types available. Double-winding latching type available. Ordering Information Classification Enclosure Ratings Coil Ratings Contact Form SPST-NO SPDT DPST-NO DPDT PCB terminal General-purpose Flux protection / G2R-A G2R- G2R-2A G2R-2 Fully sealed G2R-A G2R- G2R-2A G2R-2 Bifurcated contact Flux protection G2R-AZ G2R-Z Fully sealed G2R-AZ G2R-Z High-capacity Flux protection / G2R-A-E G2R--E High-sensitivity Flux protection G2R-A-H G2R--H G2R-2A-H G2R-2-H Double-winding latching Flux protection G2RK-A G2RK- G2RK-2A G2RK-2 Quick connect (upper bracket mounting) General-purpose Unsealed G2R-A-T G2R-T Note:. When ordering, add the rated coil voltage to the model number. Example: G2R-A 2 V Rated coil voltage 2. Models with CTI material are also available. Contact your OMRON representative for more details. 6
2 Model Number Legend G2R V Relay Function None: Single-side stable K: Double-winding latching 2. Number of Poles : pole 2: 2 poles 3. Contact Form None: PDT A: PST-NO. Contact Type None: Single Z: Bifurcated. Enclosure Ratings None: Flux protection : Fully sealed 6. Terminals None: Straight PCB T: Quick-connect (upper bracket mounting) 7. Classification None: General-purpose E: High-capacity H: High-sensitivity 8. Safety Standards None: UL/CSA/EN/SEV/TÜV SKVD: UL/CSA/EN/SEV/TÜV/SEMKO 9. Rated Coil Voltage Refer to Coil Ratings Power Relays Specifications Coil Ratings Rated voltage 2 V 2 V 00/(0) V V 0/(2)V 2 V 230 V V Rated Current 0Hz 93 ma 6. ma ma 9.3 ma. ma. ma.7 ma.7 ma 60Hz 7 ma 3 ma 9/(0.6) ma ma. (.3) ma. ma 3.8 ma 3.8 ma Coil resistance 6 Ω 260 Ω,600 Ω 6,00 Ω,0 Ω 2,000 Ω 26,80 30,000 Ω Coil inductance Armature OFF (H) (ref. value) Armature ON Must operate voltage 80% max. of rated voltage Must release voltage 30% min. of rated voltage Max. voltage 0% of rated voltage (at 23 C) Power consumption Approx. 0.9 VA at 60 Hz (approx. 0.7 VA at 60 Hz) Rated voltage V 6 V 2 V 2 V 8 V 00 V Rated current (0/60Hz) 06 ma 88.2 ma 3.6 ma 2.8 ma. ma.3 ma Coil resistance 7 Ω 68 Ω 27 Ω,00 Ω,70 Ω 8,860 Ω Coil inductance Armature OFF (H) (ref. value) Armature ON Must operate voltage Must release voltage Max. voltage Power consumption % max. of rated voltage % min. of rated voltage 70% of rated voltage (at 23 C) Approx. 0.3 W 7
3 High-sensitivity Relays Rated voltage V 6 V 2 V 2 V 8 V Rated current (0/60Hz) 7. ma 60 ma 30 ma ma ma (see Note. ) Coil resistance (see Note. ) 70 Ω 00 Ω 00 Ω,600 Ω 6,00 Ω Coil inductance Armature OFF (H) (ref. value) Armature ON Must operate voltage Must release voltage Max. voltage Power consumption % max. of rated voltage % min. of rated voltage 70% of rated voltage (at 23 C) Approx W Note:. The rated current and coil resistance are measured at a coil temperature of 23 C with a tolerance of +% / % ( rated current) or ±0% ( coil resistance) 2. Operating characteristics are measured at a coil temperature of 23 C 3. Depending on the type of relay, some relays do not have coil specifications. Contact your Omron representative for more details. Double-winding Latching Relays Rated voltage V 6 V 2 V 2 V Set Coil Rated current (see note.) 67 ma 38 ma 70.6 ma 3.6 ma Reset Coil Must set voltage Must reset voltage Coil resistance (see note.) 30 Ω 3. Ω 70 Ω 69 Ω Coil inductance Armature OFF (H) (ref. value) Armature ON Rated current 9 ma 00 ma 0 ma 2 ma Coil resistance 2 Ω 60 Ω Ω 960 Ω Coil inductance Armature OFF (H) (ref. value) Armature ON % max. of rated voltage 70% max. of rated voltage Max. voltage 0% of rated voltage (at 23 C) Power consumption Set coil: Approx. 80 mw; Reset coil: Approx. 600 mw Note:. The rated current and coil resistance are measured at a coil temperature of 23 C with a tolerance of ±0%. 2. Operating characteristics are measured at a coil temperature of 23 C. 8
4 Contact Ratings PCB/Flux Protection, Plug-in, Quick-connect Terminal Relays Item General-purpose, quick-connect terminal High-capacity Number of poles pole 2 poles pole Load Resistive load Inductive load Resistive load Inductive load Resistive load Inductive load (cosϕ = ) (cosϕ = 0.; (cosϕ = ) (cosϕ = 0.; (cosϕ = ) (cosϕ = 0.; L/R = 7 ms) L/R = 7 ms) L/R = 7 ms) Rated Load 0 A at V; A at A at V; 2 A at V; 6 A at V; 8 A at V; 0 A at 30 V V; A at 30 V 3 A at 30 V 6 A at 30 V 8 A at 30 V A at 30 V Contact material AgSnIn Rated carry current 0 A A 6 A Max. switching voltage 380 V, 2 V 380 V, 2 V 380 V, 2 V Max. switching current 0 A A 6 A Max. switching power 2,00 VA,,87 VA,, VA, 00 VA,,000 VA, 2,000 VA, 300 W 0 W 0 W 90 W 80 W W Failure rate 00 ma at V 0 ma at V 00 ma at V (reference value) Note:. P level: λ 60 = 0. x 0-6 /operation. Power Relays PCB/Flux Protection Relays Item Bifurcated contacts High-sensitivity Number of poles pole pole 2 poles Load Resistive load Inductive load Resistive load Inductive load Resistive load Inductive load (cosϕ = ) (cosϕ = 0.; (cosϕ = ) (cosϕ = 0.; (cosϕ = ) (cosϕ = 0.; L/R = 7 ms) L/R = 7 ms) L/R = 7 ms) Rated Load A at V; 2 A at V; A at V; 2 A at V; 3 A at V; A at V; A at 30 V 3 A at 30 V A at 30 V 3 A at 30 V 3 A at 30 V. A at 30 V Rated carry current A A 3 A Max. switching voltage 380 V, 2 V 380 V, 2 V 380 V, 2 V Max. switching current A A 3 A Max. switching power, VA, 00 VA,, VA, 00 VA, 70 VA, VA, 0 W 90 W 0 W 90 W 90 W W Failure rate ma at V 00 ma at V 0 ma at V (reference value) Note: P level: λ 60 = 0. x 0-6 /operation. 9
5 PCB/Fully Sealed Relays Item General-purpose (single contact) Bifurcated contact Number of poles pole 2 poles pole Load Resistive load Inductive load Resistive load Inductive load Resistive load Inductive load (cosϕ = ) (cosϕ = 0.; (cosϕ = ) (cosϕ = 0.; (cosϕ = ) (cosϕ = 0.; L/R = 7 ms) L/R = 7 ms) L/R = 7 ms) Rated Load 8 A at V; 6 A at V; A at V;. A at V; A at V; 2 A at V; 8 A at 30 V A at 30 V A at 30 V 2. A at 30 V A at 30 V 3 A at 30 V Rated carry current 8 A A A Max. switching voltage 380 V, 2 V 380 V, 2 V 380 V, 2 V Max. switching current 8 A A A Max. switching power 2,000 VA,,00 VA,,000 VA, 37 VA,, VA, 00 VA, W W W 7 W 0 W 90 W Failure rate 00 ma at V 0 ma at V ma at V (reference value) Note: P level: λ 60 = 0. x 0-6 /operation. Latching Relays Number of poles pole 2 poles Load Resistive load Inductive load Resistive load Inductive load (cosϕ = ) (cosϕ = 0.; (cosϕ = ) (cosϕ = 0.; L/R = 7 ms) L/R = 7 ms) Rated Load A at V; 3. A at V; 3 A at V;. A at V; A at 30 V 2. A at 30 V 3 A at 30 V 2 A at 30 V Rated carry current A 3 A Max. switching voltage 380 V, 2 V Max. switching current A 380 V, 2 V Max. switching power, VA, 0 W 87 VA, 7 W 70 VA, 90 W 37 VA, 60 W Failure rate 00 ma at V 0 ma at V (reference value) Note: P level: λ 60 = 0. x 0-6 /operation. 3 A
6 Characteristics Standard Relays Item Pole 2 Poles Contact resistance 30 mω max. (high-capacity type: 00 mω max.) 0 mω max. Operate (set) time Release (reset) time Max. operating frequency Insulation resistance Impulse withstand voltage Insulation Distance Creepage (Typ) Clearance (Typ) ms max : 0 ms max.; : ms max. (w/built-in diode: ms max.) Mechanical: 8,000 operations/hr Electrical:,800 operations/hr (under rated load),000 MΩ min. (at 00 V) 0KV *0µsec 0.0 mm 9.3 mm Tracking Resistance (CTI) 7 V Dielectric strength,000 V, 0/60 Hz for min,000 V, 0/60 Hz for min between coil and contacts*; between coil and contacts*;,000 V, 0/60 Hz for min 3,000 V, 0/60 Hz for min between contacts of same polarity between contacts of different polarity,000 V, 0/60 Hz for min between contacts of same polarity Vibration resistance Destruction: 0 to to 0 Hz, 0.7mm single amplitude (.mm double amplitude) Malfunction: 0 to to 0 Hz, 0.7mm single amplitude (.mm double amplitude) Shock resistance Destruction:,000 m/s 2 Malfunction: 0 m/s 2 when energized; 00 m/s 2 when not energized Endurance Mechanical: coil: 0,000,000 operations min.; coil:,000,000 operations min. (at 8,000 operations/hr) Electrical:00,000 operations min. (at,800 operations/hr under rated load) Ambient temperature Operating: -0 C to 70 C (with no icing) Ambient humidity Operating: % to 8% Weight Approx. 7 g Note: Values in the above table are initial values. Power Relays 2
7 Double-winding Latching Relays Item Pole 2 Poles Contact resistance 30 mω max. 0 mω max. Set time Reset time Min. set/reset signal width Max. operating frequency ms max ms max. 30 ms max. Mechanical: 8,000 operations/hr Electrical:,800 operations/hr (under rated load) Insulation resistance,000 MΩ min. (at 00 V) Dielectric strength,000 V, 0/60 Hz for min,000 V, 0/60 Hz for min between coil and contacts*; between coil and contacts*;,000 V, 0/60 Hz for min 3,000 V, 0/60 Hz for min between contacts of same pole; between contacts of different poles,000 V, 0/60 Hz for min,000 V, 0/60 Hz for min between set and reset coil between contacts of same pole,000 V, 0/60 Hz for min between set and reset coil Vibration resistance Destruction: 0 to to 0 Hz, 0.7mm single amplitude (.mm double amplitude) Malfunction: 0 to to 0 Hz, 0.7mm single amplitude (.mm double amplitude) Shock resistance Destruction:,000 m/s 2 (approx. 00G) Malfunction: Set: 00 m/s 2 (approx. 0G); 0 m/s 2 (approx. G) Reset: 00 m/s 2 (approx. 0G) Endurance Mechanical: 0,000,000 operations min (at 8,000 operations/hr) Electrical: 00,000 operations min. (at,800 operations/hr under rated load) Ambient temperature Operating: -0 C to 70 C (with no icing) Ambient humidity Operating: % to 8% Weight Approx. 7 g (Quick-connect type: approx. g) Note: Values in the above table are the initial values. 22
8 Approved Standards UL 08 (File No. E63), CSA 22.2 No. (File No. LR3928) Model Contact form Coil ratings Contact ratings G2R- SPDT 3 to 0 V 0 A, 30 V (resistive) G2R- 3 to V 0 A, V (general use) G2R--H TV-3 (NO contact only) G2R--S G2R--T G2R-A SPST-NO G2R-A G2R-A-H G2R-A-S G2R-A-T G2R--E SPDT 6 A, 30 V (resistive, NO contact only) 6 A, V (general use, NO contact only) G2R-A-E SPST-NO TV-3 (NO contact only); (/3 hp, V For UL) G2R-2 DPDT A, 30 V (resistive) G2R-2 A, V (general use) G2R-2-H TV-3 (NO contact only) G2R-2-S G2R-2A DPST-NO G2R-2A G2R-2A-H G2R-2A-S G2R-A-ASI SPST-NO 0 A, 30 V (resistive) 0 A, V (general use) TV-/TV-8 (NO contact only), (For UL) TV-8 (NO contact only); / hp, 2 V (For CSA) Power Relays 23
9 SEV Contact form Coil ratings Contact ratings pole 3 to 0 V 6 A, V (AgSnIn contact) 3 to V 6 A, 30 V (AgSnIn contact) 0 A, V A, V3 0 A, 30 V 2 poles A, V 2 A, 380 V A, 30 V SEMKO Contact form Coil ratings Contact ratings pole 3 to 0 V 0/80 A, V 3 to V 3/00 A, V 6/28 A, V (AgSnIn contact) 2 poles /0 A, V TÜV (EN680-) Contact form Coil ratings Contact ratings pole 3 to 0 V, 6 V to V (for Standard coil) 3 to 8 V (for K, U coil) 3 to 70 V (for H coil) 0 A, V (cosϕ =.0) 0 A, 30 V (0 ms) 6 A, V (cosϕ =.0) (AgSnIn contact) 2 poles 8 A, V (cosϕ = 0.) A, V (cosϕ =.0) A, 30 V (0 ms) 2. A, V (cosϕ = 0.) EN 680- (VDE) Contact form Coil ratings Contact ratings pole, 6, 9, 2, 8, 2, 8, 60, 00, 0 V 0 A, V (cosϕ =.0) 2, 8, 2, 8, 0, 00/(0), 0,, 0 A, 30 V (0 ms) 0/(2), 2, 230, V 6 A, V (cosϕ =.0) 2 poles, 6, 9, 2, 8, 2, 8, 60, 00, 0 V A, V (cosϕ =.0) 2, 8, 2, 8, 0, 00/(0), 0,, A, 30 V (0 ms) 0/(2), 2, 230, V 2
10 Engineering Data Maximum Switching Power Flux Protection/Plug-in Relays G2R-, G2R-A, G2R--T, G2R-A-T G2R--E, G2R-A-E G2R-Z, G2R-AZ Power Relays inductive load inductive load inductive load Switching voltage (V) Switching voltage (V) Switching voltage (V) G2R--H, G2R-A-H, G2R-2, G2R-2A G2R-2-H, G2R-2A-H inductive load inductive load G2RK-A, G2RK- Switching voltage (V) G2RK-2A, G2RK-2 Switching voltage (V) inductive load inductive load Switching voltage (V) Switching voltage (V) 2
11 Fully Sealed Relays G2R-, G2R-A G2R-2, G2R-2A G2R-Z, G2R-AZ inductive load (cosφ = 0.) inductive load (cosφ = 0.) inductive load (cosφ = 0.) Switching voltage (V) Switching voltage (V) Switching voltage (V) Endurance Flux Protection/Plug-in Relays G2R-, G2R-A, G2R--T, G2R-A-T G2R--E, G2R-A-E G2R-Z, G2R-AZ Endurance (x0 3 operations),000, V/30-V -V inductive load (cosφ = 0.) 30-V (L/R = 7ms) Endurance (x0 3 operations) 0,000,000 3,000, V (cosφ = 0.) /30-V inductive load -V/30-V Endurance (x0 operations) 3,000, V -V inductive load (cosφ = 0.) -V/30-V 00 G2R--H, G2R-A-H, G2R-2 G2R-2A G2R-2-H, G2R-2A-H G2R-3-S, G2R-A3-S Endurance (x0 operations) 3,000, V inductive load (cosφ = 0.) 30-V -V/30-V Endurance (x0 3 operations) 0,000,000 3,000, V inductive load (cosφ = 0.) -V/30-V 30-V inductive load 26
12 Engineering Data (cont.) G2RK-A, G2RK- Endurance (x0 operations) 3,000, V/30-V 30-V inductive load (L/R = 7ms) -V inductive load (cosφ = 0.) G2RK-2A, G2RK-2 Endurance (x0 3 operations) 0,000,000, V/30-V 30-V inductive load -V inductive load (cosφ = 0.) Power Relays Fully sealed Relays G2R-, G2R-A G2R-2, G2R-2A G2R-Z, G2R-AZ Endurance (x0 3 operations),000, V/30-V -V inductive load (cosφ = 0.) 30-V (L/R = 7ms) 3 Endurance (x0 operations),000, V/30-V 30-V -V inductive load (cosφ = 0.) Endurance (x0 3 operations),000, V inductive load (cosφ = 0.) 30-V inductive load -V/30-V Ambient Temperature vs Maximum Coil Voltage Maximum coil voltage (%) coil coil Note: The maximum coil voltage refers to the maximum value in a varying range of operating power voltage, not a continuous voltage. Ambient temperature ( C) 27
13 Dimensions Note:. All units are in millimetres unless otherwise indicated. 2. Orientation marks are indicated as follows: Relays with PCB Terminals SPDT Relays G2R-, G2R-Z, G2R--H 29 max. 3 max. (28.8)* * Terminal Arrangement/ Internal Connections Mounting Holes Tolerance: ± max. (2.3)* 2 3 Five,.3-dia. The illustration shows the G2R-. SPST-NO Relays G2R-A, G2R-AZ, G2R-A-H 0. 0.** **0.3 (-H Type) (2.) 29 max. (28.8)* 3 max. * max. (2.3)* 3 Four,.3-dia. The illustration shows the G2R-A. SPDT/High-capacity Relays G2R--E ** **0.3 (-H Type) (2.) 29 max. (28.8)* 3 max. * Eight,.3-dia. 2. max. (2.3)* (2.) (2.) SPST-NO/High-capacity Relays G2R-A-E 29 max. (28.8)* 3 max. * Six,.3-dia. 2. max. (2.3)* (2.) (2.) 28
14 Relays with PCB Terminals SPDT Relays G2R-, G2R-Z 2. max. (2.8)* 29 max. 3. max. (28.6)* (2.9)* Terminal Arrangement/ Internal Connections 2 3 Mounting Holes Tolerance: ± Five,.3-dia. Power Relays SPST-NO Relays G2R-A, G2R-AZ max. 3. max. (28.6)* (2.9)* (2.) max. (2.8)* 3 Four,.3-dia. (2.) Relays with PCB Terminals DPDT Relays G2R-2, G2R-2-H 29 max. 3 max. (28.8)* * Terminal Arrangement/ Internal Connections Mounting Holes Tolerance: ±0. Eight,.3-dia. 2. max. (2.2)* DPST-NO Relays G2R-2A, G2R-2A-H max. (28.8)* 0. 3 max. * (2.) (2.) Six,.3-dia. 2. max. (2.2)* (2.) (2.) DPDT Relays G2R-2 29 max. 3. max. (28.6)* (2.8)* Eight,.3-dia. 2. max. (2.7)* (2.) (2.) 29
15 DPST-NO Relays G2R-2A 29 max. 3. max. (28.6)* (2.8)* Six,.3-dia. 2. max. (2.7)* (2.) (2.) 0. Double-winding Latching Relays with PCB Terminals SPDT Relays G2RK- 29 max. 3 max. (28.8)* (2.8)* max. (2.2)* - - S 2 R Seven,.3-dia (2.) (After confirming coil polarity, wire correctly.) Double-winding Latching Relays with PCB Terminals 29 max. 3 max. SPST-NO Relays (28.8)* (2.8)* Terminal Arrangement/ Mounting Holes G2RK-A Internal Connections Tolerance: ±0. DPDT Relays G2RK-2 DPST-NO Relays G2RK-2A 2. max. (2.2)* 2. max. (2.2)* max. 3 max. (28.8)* (2.8)* max. 3 max. - - S 2 R S + R (2.) (2.) 3. (After confirming coil polarity, wire correctly.) Six,.3-dia. Eight,.3-dia. 0 (2.) (After confirming coil polarity, wire correctly.) Six,.3-dia. 2. max S + R (2.) (2.) (After confirming coil polarity, wire correctly.) 30
16 Relays with Quick-connect Terminals SPDT Relays G2R--T 30. max. (29.7)* Five,.3-dia Terminal Arrangement/Internal Connections Mounting Holes Tolerance: ± Two M3 or two 3. dia. Power Relays 29. max. SPST-NO Relays G2R-A-T 2. max. (3.9)* 30. max. (29.7)*.2 7. Five,.3-dia max. (3.)* Terminal Arrangement/Internal Connections Mounting Holes 38 3 Two M3 or two 3. dia. 29. max. 2. max. (3.9)* max. (3.)* Note: Model number of quick-connect terminal is 87. Precautions Mounting When mounting a number of relays on a PCB, be sure to provide a minimum mounting space of mm between the two juxtaposed relays as shown below. mm min. The above minimum mounting space is necessary due to mutual thermal interference generated by the relays. This restriction may be ignored, however, depending on the operating conditions of the relays. Consult OMRON for details. There is no restriction on the mounting direction of each relay on the PCB. When using this circuit, confirm the set and reset states and then take into account the circuit constant. mm min. CAT. No. K03-E2-2A-X 3
SPST-NO SPDT DPST-NO DPDT
PCB Relay A Power Relay for a Variety of Purposes with Various Models Conforms to VDE (EN680-), UL08, CSA22.2. Meets EN6033- requirements for household products. Clearance and creepage distance: 8 mm/8
More informationPCB Relay. LED indicator G2R-1A3-SN G2R-13-SN --- --- contact) LED indicator and diode DC G2R-1A3-SND G2R-13-SND --- ---
PCB Relay A Power Relay for a Variety of Purposes with Various Models Conforms to VDE045 (VDE approval: C2 insulation grade), UL8, CSA22.2, SEV, SEMKO. Meets VDE0700 requirements for household products
More informationSPST-NO SPDT DPST-NO DPDT
PCB Relay Next-generation PCB Relay Available in 2 Models Low profile:. mm max. in height Contains no lead inside and features cadmium-free contacts ensuring environment-friendly use. Conforms to VDE0
More informationType Contact material Contact form Construction Model General purpose AgCdO SPDT Semi-sealed G2R-1
Power PCB Relay G2R Creepage distance of 8.0 mm (0.31) min. between coil and contact. Dual-winding latching type available. Plug-in and quick-connect terminals available. High sensitivity (360 mw) and
More informationNumber of poles 1-pole 2-pole Minimum Enclosure Contact. G2R-1AZ G2R-1Z DC Fully sealed G2R-1AZ4 G2R-1Z4 G2R-1A-E G2R-1-E
PCB Power elay The Best Seller eneral purpose power elays of single-pole0 A and double-pole A. Safety-oriented design with dielectric strength of,000 V between coil and contacts, and surge resistance of
More informationModel Number Structure
General-purpose Relay G2RS Slim and Space-saving Power Plug-in Relay Lockable test button models now available. Built-in mechanical operation indicator. Provided with nameplate. AC type is equipped with
More informationModel Number Structure
General-purpose Relay G2RS Slim and Space-saving Power Plug-in Relay Lockable test button models now available. Built-in mechanical operation indicator. Provided with nameplate. AC type is equipped with
More informationType Sealing Poles Contacts Rated voltage Model Standard d Flux-tight 4 poles oes 3PST-NO, SPST-NC 24 VDC G7SA-3A1B 3PST-NO, 3PST-NC
Safety Relay Slim Safety Relays Conforming to EN Standards The forcibly guided contact in the assures safe operation (EN50205 Class A, approved by VDE.) Ideal for use in safety circuits in press machinery,
More informationGeneral-purpose Relay
General-purpose Relay An Improved Miniature Power Relay with Many Models for Sequence Control and Power Applications A wide range of relay variations including ones with operation indicators, high-capacity
More information3. Terminal Shape P : PCB terminals FS: Surface-mounting terminals, short FL : Surface-mounting terminals, long
Surfacemounting Relay Ultracompact and Slim DPDT Relay Suitable for highdensity mounting.(.7 mm (W). mm (L) 9 mm (H)). Dielectric strength of, VAC and an impulse withstand voltage of 2, V for 2 μs (conforms
More informationG7SA. Ordering Information. Slim Plug-In Safety Relay. Slim Safety Relay for Machine Control. H Slim body only 13 x 24 x 50 mm
Slim Plug-In Safety Relay Slim Safety Relay for Machine Control H Slim body only 13 x 24 x 50 mm (six poles) H Four-pole and six-pole models are available H Terminal arrangement simplifies PCB pattern
More informationSurface Mounting Relay
Surface Mounting Relay Surface Mounting Relay with the World s Smallest Mounting Area and a Height of Only 5.2 mm Subminiature model as small as 5.2 (H) x 6.5 (W) x 10 (L) mm is ideal for high-density
More informationOrdering Information. Latching Relay G2AK. Model Number Legend G2AK-@@@@@ 1 2 3 4 5. Magnetic Latching Version of G2A Ideal for Sequence Control
Latching Relay CSM DS_E_4_1 Magnetic Latching Version of G2A Ideal for Sequence Control Double-winding latch system with continuous rating. Terminals pulled from the respective junctions between the built-in
More informationG6K. Surface Mounting Relay with the World s Smallest Mounting Area. Model Number Legend. Application Examples. Surface Mounting Relay
with the World s Smallest Mounting Area Subminiature model as small as.2 (H). (W) (L) mm is ideal for high-density mounting ((U)-2F(-Y)). Low profile of.2 mm improves mounting efficiency ((U)-2F(-Y)).
More informationSurface Mounting Relay
Surface Mounting Relay Surface Mounting Relay with the World s Smallest Mounting Area and a Height of Only 5.2 mm Subminiature model as small as 5.2 (H) x 6.5 (W) x 10 (L) mm is ideal for high-density
More information1 POLE - 16A 80A Inrush type. (b) Contact configuration A : 1 form A (SPST-NO) C : 1 form C (SPDT) (standard type "K" only)
FTR-K1 SERIES POWER RELAY 1 POLE - 16A 80A Inrush type FTR-K1 Series FEATURES Peak 80A inrush current (1 form A type) Low profile (height: 15.7mm) HIGH INSULATION Insulation distance (between coil and
More informationRT series Miniature Printed Circuit Board Relays, Sockets and Accessories
s RT series Miniature Printed Circuit oard Relays, Sockets and ccessories pplied Coil Voltage (% of rated nom.) RT series (DC Coil) 6 mp PC oard Miniature Relay Meets VDE 0mm Spacing, KV Dielectric File
More informationAZ420 MINIATURE GENERAL PURPOSE RELAY
MINIATURE GENERAL PURPOSE RELAY FEATURES Rugged construction for high reliability Life expectancy greater than 0 million operations DC coils to 11 V Power consumption as low as 2 mw per pole available
More information2 POLES - 5A LOW PROFILE TYPE
FTR-K1 SERIES POWER RELAY 2 POLES - 5A LOW PROFILE TYPE FTR-F1 Series FEATURES Low profile (height: 16.5mm) DPST/DPDT 5A, TV-3 rating available High insulation (due to its reinforced insulation construction)
More information1 POLE - 8A Medium Load Control
POWER RELAY 1 POLE - 8A Medium Load Control JS Series FEATURES UL class B (130 C) coil wire insulation 1 form A (SPST-NO) or 1 form C (SPDT) contact Low profile and space saving - Height: 12.5 mm - Mounting
More information1 POLE 5 A (CADMIUM FREE CONTACTS TYPE) NY SERIES
POWER RELAY 1 POLE 5 A (CADMIUM FREE CONTACTS TYPE) NY SERIES RoHS compliant FEATURES Ultra slim type with 5 mm thickness Good for high density mounting Low power consumption and high sensitivity Nominal
More informationSZR-LY Series. General Purpose Power Relay WARNING WARNING. Sensing and Control
Power Relay FEATURES Small package design ARC barrier equipped Silver Cadium Oxide contact High dielectric strength (,800 Vac) High reliability and long life Ultra-high sensitivity with quick response
More informationGoodsky Technical Data. Contact Details
Goodsky Technical Data The following page(s) are extracted from multi-page Goodsky product catalogues or CDROMs and any page number shown is relevant to the original document. The PDF sheets here may have
More information1 POLE - 16A 80A Inrush type. (a) Relay type FTR-K1 : FTR-K1-Series
FTR-K1 SERIES POWER RELAY 1 POLE - 16A 80A Inrush type FTR-K1 Series FEATURES Peak 80A inrush current (1 form A type) Low profile (height: 15.7mm) High insulation Insulation distance (between coil and
More informationRY2 miniature industrial relays
6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,
More information(e) Enclosure B : Flux proof type, RTII C : Plastic sealed type (with tape), RTIII K : Plastic sealed type, RTIII
Non-promotional not for new designs FTR-K1 SERIES POWER RELAY 1 POLE - 10A VS Series FEATURES UL, CSA, VDE, SEV, SEMKO, CQC recognized TV-5 is available Working class: C UL class B (130 C) coil wire insulation
More information60 Series - General purpose relays 6-10 A. Features 60.12 60.13
Features 60.12 60.13 Plug-in mount 10 A General purpose relay 2 & 3 pole changeover contacts Cadmium Free contacts (preferred version) AC coils & DC coils UL Listing (certain relay/socket combinations)
More informationSILENT POWER RELAY. FTR-H3 Series. 1 POLE - 78A/120A Inrush Current Type FTR-K1 SERIES FEATURES
FTR-K1 SERIES SILENT POWER RELAY 1 POLE - 78A/120A Inrush Current Type FTR-H3 Series FEATURES Pin compatible with widely used VS and FTR-H1 series power relays Silent relay with patented unique U-shape
More information1a/1c 5A/10A small power relays
VDE a/c A/A small power relays RELAYS RoHS compliant FEATURES High electrical noise immunity High switching capacity in a compact package High sensitivity: mw (a), mw (c) High surge voltage:, V between
More informationDATA SHEET COMPACT AND LIGHTWEIGHT, SMALL MOUNTING SIZE, HIGH BREAKDOWN VOLTAGE
DATA SHEET MINIATURE SIGNAL RELAY EC SERIES COMPACT AND LIGHTWEIGHT, SMALL MOUNTING SIZE, HIGH BREAKDOWN VOLTAGE DESCRIPTI The EC series has reduced mounting space but sustained high-performance of NEC
More information2 POLES 1 to 2 A (FOR SIGNAL SWITCHING)
MINIATURE RELAY 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) RY SERIES FEATURES Ultra high sensitivity UL, CSA recognized Conforms to FCC rules and regulations Part 68 Surge strength 1,500 V High dielectric
More informationStandard with LED indicator
General-purpose Relay MY Versatile, Multi-featured, Miniature Power Relay for Sequence Control and Power Switching Applications Models with lockable test buttons now available. Multiple features available,
More information48 SERIES Relay interface modules 10 A
48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply
More informationTQ SMD RELAYS TQ SMD LOW-PROFILE SURFACE-MOUNT RELAY FEATURES SPECIFICATIONS
LOW-PROFILE SURFACE-MOUNT RELAY RELAYS.55 5.6. FEATURES Low-profile: 6 mm.36 inch (Tape height: max. 6.5 mm.56 inch) Tape and reel package is available as standard packing style Surge withstand between
More informationPOWER RELAY. FTR-K1-KS Series. 1 POLE - 16A / Inrush 120A relay FTR-K1 SERIES FEATURES
POWER RELAY POLE - 6A / Inrush 20A relay FTR-K-KS Series FTR-K SERIES FEATURES pole 6A, form A or form C Peak inrush current 20A / TV-8 Coil power 400mW High insulation in small package (between coil and
More informationDISCONTINUED (1998) FBR46 SERIES. MINIATURE RELAY 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) RoHS compliant FEATURES
MINIATURE RELAY 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) FBR46 SERIES RoHS compliant FEATURES Miniature size About 50% smaller in volume compared with the FBR240 series used mainly in communication equipment.
More informationCQM1-SF200/CS1W-SF200
Safety Relay Unit ( I/O Unit Type) CQM1-SF200/CS1W-SF200 CSM_CQM1-SF200_CS1W-SF200_DS_E_2_1 A Safety Relay Unit That Functions as a I/O Unit. Less Installation Space and Wiring Required. Safety Relay Unit
More information38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
More information40 Series - Miniature PCB/Plug-in relays 8-10 - 16 A. Features 40.31 40.51 40.52
Features 40.31 40.51 40.52 1 & 2 Pole relay range 40.31-1 Pole 10 A (3.5 mm pin pitch) 40.51-1 Pole 10 A (5 mm pin pitch) 40.52-2 Pole 8 A (5 mm pin pitch) PCB mount - direct or via PCB socket 35 mm rail
More informationPOWER RELAY. JV Series. 1 POLE - 5A/10A Medium Load Control FTR-K1 SERIES FEATURES
FTR-K1 SERIES POWER RELAY 1 POLE - 5A/10A Medium Load Control JV Series FEATURES UL, CSA, VDE, SEMKO, CQC recognized UL class B (130 C) wire class Low profile and space saving - Height: 12.5 mm - Mounting
More information48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.
48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according
More informationDISCONTINUED (2012) VB SERIES 2 POLE 5 A (MEDIUM LOAD CONTROL) POWER RELAY. RoHS compliant
POWER RELAY 2 POLE 5 A (MEDIUM LOAD CONTROL) VB SERIES RoHS compliant FEATURES UL, CSA, VDE, SEV, SEMKO, CQC recognized TV-3 rated Working class: C UL class B (130 C) insulation Type of service: continuous
More information0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N
55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils
More informationSignal Relays AXICOM. P2 Relay V23079. AXICOM Telecom-, Signal and RF Relays. P2 V23079 Relay. Coil Operating Range. Coil Data
P Relay V379 n Standard telecom relay (ringing and test access) n Slim line 5x7.5mm (.59x.95 ) n Max. switching current 5A n form C bifurcated contacts ( changeover contacts, CO) n Immersion cleanable
More information38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical
More information1 POLE - 5A SLIM POWER RELAY
POWER RELAY POLE - A SLIM POWER RELAY FTR-MY Series RoHS compliant FEATURES Width mm, height mm,(% smaller than NY series) area mm, super slim, low power, compact and light weight.gr. Nominal power: mw
More informationPluggable interface relays CR-P Pcb relays
2CDC 293 034 F0004 1 2 4 3 Features 9 different supply s: DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2 c/o (8 A) Cadmium-free contact
More informationType Terminal Coil Contact form Model
General Purpose Relay MK Exceptionally reliable general purpose relay. Long life (minimum 100,000 electrical operations) assured by silver contacts. Built-in operation indicator (mechanical, LED), diode
More informationNA Series. 2 POLES - 1 to 2 A (For Signal Switching) MINIATURE RELAY FTR-K1 SERIES
FTR-K1 SERIES MINIATURE RELAY 2 POLES - 1 to 2 A (For Signal Switching) NA Series FEATURES Slim type relay for high density mounting Conforms to Telcordia specification and FCC Part 68 - Dielectric strength
More information1 pole, 16 A Screw terminal connection 35 mm rail (EN 60715) mounting. 2 pole, 8 A Screw terminal connection 35 mm rail (EN 60715) mounting
Series - Relay interface modules 8-10 - 16 A Features.01.02 1 & 2 pole relay interface modules, screw terminal socket, mm wide. Ideal interface for PL and electronic systems.01-1 Pole 16 A.02-2 Pole 8
More informationRM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
More informationD2SW-P. Sealed Subminiature Basic Switch. Ordering Information
Sealed Subminiature Basic Switch Sealed Basic Switch with Simplified Construction, Mounting Compatible with SS and D2SW Series. Sealing by using rubber packing means the switch can be used in dust-proof
More informationFP2 Relay. The Best Relaytion
The Best Relaytion 2 pole telecom / signal relay Through Hole Type (THT) Polarized. Relay types: non-latching with1 coil latching with 1 coil latching with 2 coils Features Telecom / signal relay (dry
More informationSlim Relay G2RV. Features. Test switch operation. Protection cover: lock. Protection cover: unlock. Protection cover open. Protection cover close
Slim Relay GRV The only truly industrial 6 mm relay Lockable test switch models now available. Large plug-in terminals for reliable connection. LED indicator and mechanical flag for status indication.
More information4 A CAPACITY, THE VARIETY OF CONTACT ARRANGEMENTS FEATURES
4 A CAPACITY, THE VARIETY OF CONTACT ARRANEMENTS S RELAYS FEATURES 28. 1.12 12..472 1.4.49 The variety of contact arrangements 2 Form A 2 Form B, 3 Form A 1 Form B, 4 Form A Latching types available High
More information1 POLE - 16A / Inrush 120A relay. (a) Relay type FTR-K1 : FTR-K1 Series (b) Contact configuration A : 1 form A C : 1 form C
FTR-K1 SERIES POWER RELAY 1 POLE - 16A / Inrush 120A relay FTR-K1-KS Series FEATURES 1 pole 16A, 1 form A or 1 form C Peak inrush current 120A / TV-8 Coil power 400mW High insulation in small package (between
More information38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.
38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC
More informationReed V23100-V4 Relay. AXICOM Telecom-, Signal and RF Relays. AXICOM Telecom-, Signal and RF Relays. Reed V23100-V4 Relay
AXICOM AXICOM 108-98011 Nov. 07 Rev. C ECOC: JM10 Disclaimer While Tyco Electronics has made every reasonable effort to ensure the accuracy of the information in this datasheet, Tyco Electronics does not
More informationRelays. Relays. RH Series. RH Series General Purpose Midget Relays. Specifications
RH Series RH Series General Purpose Midget Key features of the RH series include: Compact midget size saves space High switching capacity (A) Choice of blade or PCB style terminals Relay options include
More information34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51
34 Series - Slim electromechanical PCB relays 6 34 SERIES Features 34.51 Ultra-slim 1 Pole - 6 relay Printed circuit mount - direct or via PCB socket 35 mm rail mount - via screw, screwless or push-in
More informationHIGH REPEATABILITY, BROADBAND TO-5 RELAYS DPDT
HIGH REPEATABILITY, BROADBAND TO-5 RELAYS DPDT SERIES RF00 RF00D RF00DD RF0 RF0D RF0DD RELAY TYPE Repeatable, RF relay Repeatable, RF relay with internal diode for coil transient suppression Repeatable,
More informationThe Best Relaytion. Reed Relays. 108-98011 Rev. B EC-JM00-0009-03 ECOC: JM10 1. Aug. 04
The Best Relaytion Reed Relays 108-98011 Rev. B EC-JM00-0009-03 ECOC: JM10 1. Aug. 04 1 and 2 pole relays non-polarized, non-latching Features Direct coil control with TTL-signals possible Highly reliable
More informationSKR - industry relay
SKR - industry relay the universal relay SKR the time module STM the socket The strengths of the SKR industry relay lie in the mature and thoughtout construction. Over-average contact safety and life time,
More informationLAUBE TECHNOLOGY DRY REED RELAYS
LAUBE TECHNOLOGY DRY REED RELAYS CONTACT FORM CURRENT PART SERIES PAGE #'S (1A) SPST-NO 1 AMP D41A...0L 147~148 (Link) (1A) SPST-NO 1 AMP D71A.1.0 149~150 (Link) (1A) SPST-NO 1 AMP F51A.100 151~152 (Link)
More informationLOW PROFILE 2 FORM C RELAY 9.354 +0.4 5.197 0.2 +.016.008. mm inch. M.B.B.type. Initial breakdown voltage 1 A 30 V DC 30 W, 62.5 V A 30 W.
TESTING LOW PROFILE FORM C RELA TQ-RELAS 9.35 6.7..5 5..6.8.55 9.35. 5..6.8 FEATURES High sensitivity: Form C: power consumption (single side stable type) Form C: 8 power consumption (single side stable
More information49 Series - Relay interface modules 8-10 - 16 A. Features
Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole
More informationD2QW D2QW-@@@@@- @ - @ 1 2 3 4 5 6 7. Sealed long stroke slide-contact switch for reliable ON/OFF action even in severe environmental conditions.
Sealed long stroke slide-contact switch for reliable ON/OFF action even in severe environmental conditions. Extra-long stroke even without levers. (:.7 mm) Clip contacts with highly reliable slide contact
More informationDISCONTINUED (2009) RA SERIES. 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) MINIATURE RELAY. RoHS compliant
MINIATURE RELAY 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) RA SERIES RoHS compliant FEATURES Ultra high sensitivity (75 to 150 mw) High reliability-bifurcated contacts Conforms to FCC rules and regulations
More informationA SERIES. 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) MINIATURE RELAY. RoHS compliant
MINIATURE RELAY 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) A SERIES RoHS compliant FEATURES Extremely low profile and light weight Height: 5 mm Weight: approximately 1.2 g Meet FCC (Part 68) standard Conforms
More informationGeneral-purpose Relays
General-purpose Relays MK-S New Model General-purpose Relays Featuring Mechanical Indicator and Lockable Test Button Built-in operation indicator (mechanical and LED), and new models with lockable test
More informationHow To Read A Pipe From A Sensor
Liquid Level Sensor Installation on pipes. Sensing by means electrostatic capacity and is not influenced by the color of the pipe or liquid. Available in 8 to mm dia. and to mm dia. models to enable sensing
More informationRelays & Sockets. RH Series Compact Power Relays. Part Number Selection
RH Key features SPDT through PDT, 0A contacts Compact power type relays Miniature power relays with a large capacity 0A contact capacity Compact size saves space Contact SPDT DPDT PDT PDT RH Series Compact
More informationElectronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
More informationSafety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
More informationRM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
More informationDISCONTINUED (1998) MINIATURE RELAY 1 POLE 1 to 2 A (FOR SIGNAL SWITCHING) FBR211 SERIES. RoHS compliant
MINIATURE RELAY POLE to 2 A (FOR SIGNAL SWITCHING) FBR2 SERIES RoHS compliant FEATURES 2 A maximum carrying current Capable of 2 A maximum continuous carrying current in the contact Superior reliability
More informationGeneral Purpose Relays Types K, R, N, and C
General Purpose Relays s K, R, N, and C Catalog 0CT00R/0 00 Class 0 CONTENTS Description............................................. Page R Miniature Plug-in Relays.............................. K Plug-in
More informationSolid-State Timer H3G
ASH & ALAIN INDIA PVT LTD S-100, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-11000(India) Tel : 011-43797575 Fax : 011-43797574 E-mail : sales@ashalain.com Solid-State Timer Low-Cost, Plug-In
More informationYour Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.
Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description
More informationType: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
More informationRM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters
Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main
More informationFeatures. Type List 832A
Type List Terminal style PCB terminal A Contact form 1B (SPNC) 1B (SPNC) Insulation eatures Heavy duty 30A general purpose Power Relays. UL/CUL (UL 508 & 873), VDE safety approvals. Optional for open frame,
More informationProduct Catalogue. Relays with forcibly guided contacts
Product Catalogue Relays with forcibly guided contacts Product Catalogue - Relays with forcibly guided contacts Edition / Publisher: ELESTA relays GmbH, Bad Ragaz, Switzerland All rights reserved. This
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...
Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast
More informationAXICOM Telecom-, Signal and RF Relays. Cradle Relay S V23054 / V23062. 108-98014 Nov. 07 Rev. C ECOC: JM10
Cradle Relay S V23054 / V23062 108-98014 Nov. 07 Rev. C ECOC: JM10 Disclaimer While Tyco Electronics has made every reasonable effort to ensure the accuracy of the information in this datasheet, Tyco Electronics
More informationVIBRATION MONITORING OF FANS INSTALLED IN ROAD TUNNELS
VIBRATION MONITORING OF FANS INSTALLED IN ROAD TUNNELS CEMB SPA Via Risorgimento, 9 Mandello del Lario (Lc), Italy stm@cemb.com www.cemb.com INSTRUMENT FOR MONITORING VIBRATIONS OF FANS INSTALLED IN ROAD
More informationPOWER ROCKER SWITCH UL, CSA, VDE, TÜV, ÖVE, KEMA, SEMKO, NEMKO, DEMKO, FIMKO, SEV UL, CSA, VDE, TÜV, SEMKO, NEMKO, DEMKO, FIMKO, SEV, KEMA, ÖVE
POWER ROCKER SWITCH SWITCHES AJ8 switch standard actuator AJ8 switch Wide actuator RoHS Directive compatibility information http://www.nais-e.com/ FEATURES 1. Power rocker switches for safety requirements.
More informationRelays and Timers Specifications Bulletin Number 700
Technical Data Relays and Timers Specifications Bulletin Number 700 Topic Page General Purpose Relays 2 Timing Relays 41 NEMA Industrial Relays 81 IEC Control Relays 93 Solid State Relays 109 Additional
More informationVEO. V4PF480Y/277VSYTK02 Art.Nr.: 2104200. V4PF480Y/277VSYTK02P Art.Nr.: 2104210 TECHNICAL DATA
Monitoring of phase sequence and phase loss Monitoring of asymmetry Temperature monitoring (PTC) Supply voltage 208-480 V AC Supply circuit = measuring circuit 2 change-over contacts Width 45 mm Control
More informationClear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles
Clear Glass Sensor Optimum Sensor for Detecting Transparent Glass and Plastic Bottles E3S-CR67/62 Retroreflective Sensor smoothly detects 5-mm gaps. Detects transparent bottles that have a lens effect.
More informationType: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC
More informationHIGH REPEATABILITY SPDT, BROADBAND 12 GHZ MAGNETIC-LATCHING RF RELAY
HIGH REPEATABILITY SPDT, BROADBAND 12 GHZ MAGNETIC-LATCHING RF RELAY SERIES RF121 RELAY TYPE RF Magnetic-Latching, SPDT, Through-hole Relay DESCRIPTION The ultraminiature RF121 relay is built on Teledyne
More informationLC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil
Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -
More informationDATA SHEET COMPACT AND LIGHTWEIGHT, SMALL MOUNTING SIZE, HIGH BREAKDOWN VOLTAGE
DATA SHEET MINIATURE SIGNAL RELAY EC SERIES COMPACT AND LIGHTWEIGHT, SMALL MOUNTING SIZE, HIGH BREAKDOWN VOLTAGE DESCRIPTI The EC series has reduced mounting space but sustained high-performance of NEC
More informationSpecifications H8CA-S H8CA-S RATINGS. Approved by the following standards CHARACTERISTICS
Solid-State Counter/Timer 1/16 DIN, Easy-to-Operate Combination Counter and Timer Operation selectable as preset counter or timer 6-digit LCD Present Value: 8 mm (.32 in) Set Value: 4 mm (.16 in) Nonsignificant
More informationType: DILM32 10(24V50HZ) Article No.: 277247
Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,
More informationCross-beam scanning system to detect slim objects. 100 mm 3.937 in
891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC
More informationONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.
ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD SWITCHES FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.2g) Solder terminal type with mounting holes (0.3g)
More informationE-STOP relays, safety gate monitors
Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
More informationCount input Display Time range 999999.9h or 3999d23.9h (selectable) 999h59m59s or 9999h59.9m (selectable) 3. Case Color B: Black
R Self-Powered Time Counter Subminiature Time Counters With Enhanced Appearance and Features H Large display with 8.6 mm (0.338 in) height H Available with backlit LCD H PNP/NPN DC voltage available H
More information