ONLINE DATA SHEET. UE410-MM3 Flexi Classic SAFETY CONTROLLERS
|
|
- Blanche Jenkins
- 7 years ago
- Views:
Transcription
1 ONLINE DATA SHEET UE410-MM3 Flexi Classic
2 A B C D E F Illustration may differ Ordering information Type Part no. UE410-MM Other models and accessories H I J K L M N O P Q R S T Detailed technical data Features Module Configuration method Safety-related parameters Main module Via rotary switch Safety integrity level SIL3 (IEC 61508) SILCL3 (EN 62061) Category Category 4 (EN ISO 13849) Performance level PL e (EN ISO 13849) PFHd (mean probability of a dangerous failure per hour) 2.5 x 10-9 (EN ISO 13849) T M (mission time) 20 years (EN ISO 13849) Functions Restart interlock External device monitoring (EDM) Differentiation between man and material (muting) Interfaces Inputs Override Concurrence monitoring Monitoring of total muting time Sensor gap monitoring End of muting by ESPE Number of muting sensors 2 / 4 Outputs Manual / automatic (configurable) 2 safety inputs 2 switching inputs 4 muting inputs 2 safety outputs 2 test outputs 2 diagnostic outputs 2 SENS:CONTROL - SAFE CONTROL SOLUTIONS SICK Online data sheet :01:50 Subject to change without notice
3 Connection type Permitted cross-section Finely stranded with ferrules (1x) Finely stranded with ferrules (2x) Display elements Fieldbus, industrial network Type of fieldbus integration Plug-in screw-type terminals 0.14 mm² mm² 0.14 mm² mm² 0.25 mm² mm² 0.25 mm² mm² LEDs CANopen DeviceNet EtherNet/IP Modbus TCP PROFIBUS DP PROFINET Gateway Electrical data Protection class III (EN 61140) Type of voltage supply PELV or SELV 1) Supply voltage V S 24 V DC (19.2 V DC V DC) Residual ripple 10 % Power consumption Switch-on time 3 W (DC) 10 s 1) The current of the power supply that powers the main unit must be limited to a maximum of 4 A, either through the power supply itself or a fuse. Mechanical data Dimensions (W x H x D) Weight 22.5 mm x 96.5 mm x mm 180 g Ambient data Enclosure rating Housing IP 40 (EN 60529) Terminals IP 20 (EN 60529) Ambient operating temperature 25 C C Storage temperature 25 C C Air humidity 15 % %, Non-condensing Climate conditions according to EN (55 C ambient operating temperature, 95% rel. humidity) Electromagnetic compatibility (EMC) Class A (EN , EN 55011) Vibration resistance 5 g RMS, 5 Hz Hz (EN ) :01:50 Online data sheet Subject to change without notice SENS:CONTROL - SAFE CONTROL SOLUTIONS SICK 3
4 A B C D E F Dimensional drawing (dimensions in mm (inch)) (4.5) 78 (3.07) 58 (2.28) 93.7 (3.69) (4.76) H I J K L M N O P Q R S T 93.3 (3.67) 96.5 (3.8) 67 (2.64) 85 (3.35) 22.5 (0.89) 4 SENS:CONTROL - SAFE CONTROL SOLUTIONS SICK Online data sheet :01:50 Subject to change without notice
5 USmod 4c int43 Australia Phone tollfree sales@sick.com.au Belgium/Luxembourg Phone +32 (0) info@sick.be Brasil Phone marketing@sick.com.br Canada Phone information@sick.com Česká republika Phone sick@sick.cz China Phone info.china@sick.net.cn Phone ghk@sick.com.hk Danmark Phone sick@sick.dk Deutschland Phone info@sick.de España Phone info@sick.es France Phone info@sick.fr Great Britain Phone +44 (0) info@sick.co.uk India Phone info@sick-india.com Israel Phone info@sick-sensors.com Italia Phone info@sick.it Japan Phone +81 (0) support@sick.jp Magyarország Phone office@sick.hu Nederland Phone +31 (0) info@sick.nl Norge Phone sick@sick.no Österreich Phone +43 (0) office@sick.at Polska Phone info@sick.pl România Phone office@sick.ro Russia Phone info@sick.ru Schweiz Phone contact@sick.ch Singapore Phone sales.gsg@sick.com Slovenija Phone +386 (0) office@sick.si South Africa Phone info@sickautomation.co.za South Korea Phone /4 info@sickkorea.net Suomi Phone sick@sick.fi Sverige Phone info@sick.se Taiwan Phone sales@sick.com.tw Türkiye Phone +90 (216) info@sick.com.tr United Arab Emirates Phone +971 (0) info@sick.ae USA/México Phone +1(952) tollfree info@sickusa.com More representatives and agencies at SICK AG Waldkirch Germany
ONLINE DATA SHEET WT34-R220 W34 PRODUCT PORTFOLIO
ONLINE DATA SHEET WT34-R220 W34 A B C D E F WT34-R220 W34 Illustration may differ Ordering information Type Part no. WT34-R220 1019233 Other models and accessories www.sick.de/w34 H I J K L M N O P Q R
More informationONLINE DATA SHEET. www.mysick.com. Contrast sensors KTM KTM-WP11181P
ONLINE DATA SHEET www.mysick.com Contrast sensors KTM KTM-WP11181P Contrast sensors KTM Model Name > KTM-WP11181P Part No. > 1062199 At a glance Established mini housing High grayscale resolution Increased
More informationPhotoelectric sensors W100, Photoelectric proximity sensor, energetic
ONLINE DATA SHEET www.mysick.com Photoelectric sensors W100, Photoelectric proximity sensor, energetic WT100-P4439 Photoelectric sensors W100, Photoelectric proximity sensor, energetic Model Name > WT100-P4439
More informationColor sensors CS8, CS8-1
ONLINE DATA SHEET www.mysick.com Color sensors CS8, CS8-1 CS81-P1112 Color sensors CS8, CS8-1 Model Name > CS81-P1112 Part No. > 1028224 At a glance One (CS8-1) or four (CS8-4) colors can be saved 12.5
More informationPhotoelectric sensors V180-2, Photoelectric retro-reflective sensor, Standard optics
ONLINE DATA SHEET www.mysick.com Photoelectric sensors V180-2, Photoelectric retro-reflective sensor, Standard optics VL180-2P42436 Photoelectric sensors V180-2, Photoelectric retro-reflective sensor,
More informationfiber-optic sensors WLL180T, Fiber-optic photoelectric sensor
ONLINE DATA SHEET www.mysick.com fiber-optic sensors WLL180T, Fiber-optic photoelectric sensor WLL180T-P434 fiber-optic sensors WLL180T, Fiber-optic photoelectric sensor Model Name > WLL180T-P434 Part
More informationD ATA S H E E T. DT50 Laser class 1. Laser distance sensor
D ATA S H E E T DT50 Laser class 1 Laser distance sensor DT50 Distance sensor Laser class 1 State-of-the-art time of flight technology for fast and accurate measurement results (range up to 10 m) Quick
More informationBar code scanners CLV45x / CLV450 / Standard Density
ONLINE DATA SHEET www.mysick.com Bar code scanners CLV45x / CLV450 / Standard Density CLV450-0010 Bar code scanners CLV45x / CLV450 / Standard Density Model Name > CLV450-0010 Part No. > 1018556 At a glance
More informationBar code scanners CLX49x / CLX490 / Standard Density
ONLINE DATA SHEET www.mysick.com Bar code scanners CLX49x / CLX490 / Standard Density CLX490-0010 Bar code scanners CLX49x / CLX490 / Standard Density Model Name > CLX490-0010 Part No. > 1019318 At a glance
More informationV180-2 M18 Cylindrical Photoelectric Sensor Series
D ata S h e e t V80-8 Cylindrical Photoelectric Sensor Series A rounded concept, not only economically. Cylindrical photoelectric switches offer the benefits of very fast commissioning and compact design.
More informationPRODUCT INFORMATION. Teach me twice! One principle, two housings: MZ2Q for T- and C-slots magnetic cylinder sensors with two adjustable switch points.
PRODUCT INFORMATION Teach me twice! One principle, two housings: MZ2Q for T- and C-slots magnetic cylinder sensors with two adjustable switch points. MZ2Q-T and MZ2Q-C: convincingly flexible, vanishingly
More informationDT50 A new age in Laser Distance Measurement
Product information DT50 A new age in Laser Distance Measurement Redefining Performance Maximum performance for your application Automation solutions, and sequences, are becoming increasingly complex,
More informationEnkoder absolutne AFS/AFM60 EtherNet/IP, Rotary
KATALOG ONLINE www.mysick.com Enkoder absolutne AFS/AFM60 EtherNet/IP, Rotary AFM60A-BHIB018X12 Enkoder absolutne AFS/AFM60 EtherNet/IP, Rotary Nazwa modelu > AFM60A-BHIB018X12 Numer części > 1055328 At
More informationGas flow measuring devices Ultrasonic gas flow meter, FLOWSIC600
ONLINE DATA SHEET www.mysick.com Gas flow measuring devices Ultrasonic gas flow meter, FLOWSIC600 FLOWSIC600 2plex Gas flow measuring devices Ultrasonic gas flow meter, FLOWSIC600 Model Name > FLOWSIC600
More informationPRODUCT INFORMATION. SICK Remote Service Product and System Support. Secure remote monitoring for efficient service
PRODUCT INFORMATION SICK Remote Service Product and System Support Secure remote monitoring for efficient service Modular service contracts - flexible for every requirement An important part of LifeTime
More informationALIS Barcode / RFID Airport Luggage Identification System. Making sure your luggage gets there
Product Information ALIS Barcode / RFID Airport Luggage Identification System Making sure your luggage gets there The most reliable solutions for handling your baggage. SICK tailor-made solutions from
More informationHow To Use An Od Max Sensor System For Distance Measurement
OD Max: Highly precise distance measurement thickness or the evenness can be achieved. This is due to the in the system integrated arithmetical functions. D T SHEET Displacement TThe OD Max is an highly
More informationThe new generation: WLL180T photoelectric sensor with fiber-optic cable. Around the corner at High Speed
P r o d u C t i n f o r m at i o n The new generation: WLL180T photoelectric sensor with fiber-optic cable Around the corner at High Speed WLL180T: World-class performance and scanning range SICK has been
More informationCLV440/442 Bar Code Scanner
PRODUCT INFORMATION CLV440/442 Bar Code Scanner Advanced line CLV440/442 Bar Code Scanner: Dynamic focus control Compact but powerful The bar code scanners CLV440/442 represent the newest members of our
More informationHIPERFACE DSL The digital evolution. The new digital interface for servo motors
HIPERFACE DSL The digital evolution The new digital interface for servo motors Continuing the tradition of world class excellence in interface communication technology Introducing HIPERFACE DSL. With SSI
More informationDRS61: Incremental encoders, number of lines and zero pulse width freely programmable DRS60: Incremental Encoders with Zero-Pulse-Teach
RS: Incremental encoders, number of lines and zero pulse width freely programmable RS: Incremental Encoders with Zero-Pulse-Teach Further highlights of this generation of encoders: Simple zero-pulse-teach
More informationFor accurate positioning in warehouse and conveying areas
TECHNICAL DESCRIPTION DMP Position finder For accurate positioning in warehouse and conveying areas AUDIN - 8, avenue de la malle - 170 Saint Brice Courcelles - Tel : 0..0.0.1 - Fax : 0..0.8.0 - Web :
More informationHIPERDRIVE HRA71 and HIPER- DRIVE -HUB: Integrated positioning system with absolute distance measurement for format adjustment
HIPERDRIVE HRA7 and HIPER- DRIVE -HUB: Integrated positioning system with absolute distance measurement for format adjustment Convincing benefits: Highly integrated system Low cabling requirements: VDC
More informationS OUNTING INSTRUCTION M M o u n t i n g k i t 2 &
M O U N T I N G I N S T R U C T I O N S instructions This document is protected by copyright. The SICK AG company retains this right. Reproducing this document in whole or part is only permissible within
More informationPRODUCT INFORMATION. SICK LifeTime Services. LifeTime Services for Machines and Systems
PRODUCT INFORMATION SICK LifeTime Services LifeTime Services for Machines and Systems Ordering Information Place your trust in us... SICK LifeTime Services Place your trust in us... SICK LifeTime Services
More informationW 18-3: Incorporated application Know-how, expanded functionality, high level of equipment availability
Photoelectric proximity switches, FGS Photoelectric reflex switches Through-beam photoelectric switches W -: Incorporated application Know-how, expanded functionality, high level of equipment availability
More informationStorage and conveyor APPLICAtIoNS EFFICIENtLY SoLVED
Applications efficiently solved TASKS in storage and conveyor Industry Flexibility and cost-efficiency The competitive advantage in storage and conveyor systems The storage and conveyor system plays a
More informationUniversal or individual application solutions. WLL190T-2. Sensor Configuration for Individual Applications
MANUAL Universal or individual application solutions. Fast and reliable programming menu driven and at the push of a button: sensor properties and parameters are individually determined directly on the
More informationCONFIGURABLE SAFETY RELAYS
MSI-s/R, MSI-sx/Rx Configurable MSI provide important functions for the efficient flow of automated production processes Special features Combined guarding types by connecting up to 4 AOPDs Additional
More informationCONFIGURABLE SAFETY RELAYS
MSI-m/R, MSI-mx/Rx Configurable MSI Safety Relay with function for efficient material flow in a packaging application Special features Sequential or Parallel with automatic mode detection MSI-mx for separate
More informationXUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm
Characteristics XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm Complementary Detection system Kit composition [EAA] effective aperture angle Emission Main Range of product Product or
More informationDigital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
More informationYour Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.
Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description
More informationOnline data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS
Online data sheet PET-1CB010N10SVMC PET B C D E F H I J K L M N O P Q R S T Illustration may differ Detailed technical data Features Pressure type Measuring range Ordering information Other models and
More informationSet for PROFINET IO in IP20 TI-BL20-EN-PN-4
Cable max. 50 m between interface and read/write head Connection of up to 4 read/write heads via BL ident extension cables Mixed operation of HF and UHF read/ write heads Connectors /S2500 Type code Ident
More informationAS-i 3.0 Gateways, PROFIsafe via PROFINET or PROFIBUS
via PROFINET or AS-i 3.0 Gateways, via PROFINET or 2 / 1 Master, PROFINET / Slave AS-i Safety input slaves report via AS-i Safety output slaves switch via 1 Safety Monitor for 2 AS-i networks Operation
More informationR4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT ... ... Spur 2. Spur 1. Zone 1. Zone 0
FieldBarrier Features Assembly 8... 12 outputs Ex ia IIC, FISCO and Entity Advanced fault isolation and diagnostics at the spur FieldBarrier in Zone 1/Div. 2 Instruments in Zone 0...1/Div. 1 For FOUNDATION
More informationAgilent 87421A/87422A Power Supply
Agilent 87421A/87422A Power Supply Technical Overview Designed specifically for Agilent Technologies microwave system amplifiers Bias cable permits remote placement Compact size for easy system integration
More informationTX OPEN RS232/485 module
s 8 185 8185P01 TX-I/O ; DESIGO OPEN TX OPEN RS/485 module for integrating third-party systems and devices to DESIGO (V4 or higher) TXI1.OPEN Platform to integrate third-party systems and devices to the
More informationNGC-30 Programming Guide
NGC-30 Programming Guide Addendum A INDUSTRIAL HEAT TRACING SOLUTIONS EN-RaychemNGC30-IM-INSTALL129 R2 This document describes new features of the DigiTrace NGC-UIT which are not published in its entirety
More informationProgrammable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2
Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male
More informationSAFETY LIGHT CURTAINS
SAFETY LIGHT CURTAINS Overview Safety Light Curtains with resolutions that can be reduced guarantee protection and tolerate work equipment in the protective field The Safety Light Curtains comply with
More informationPNOZsigma - Base units
PNOZsigma - Base units Register Login Sensors Control and Communication Electronic monitoring relays Safety Relays PNOZ X PNOZsigma PNOZelog PNOZmulti PNOZpower Configurable control systems Programmable
More informationMake the invisible visible! SENSORS WITH EXCELLENT BACKGROUND SUPPRESSION
Make the invisible visible! SENSORS WITH EXCELLENT BACKGROUND SUPPRESSION photoelectric sensors Thanks to its vision for innovation and technological enhancement, Contrinex keeps on setting new standards
More informationSafety technique. Emergency stop module BO 5988 safemaster
Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1
More informationE-STOP relays, safety gate monitors
Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
More informationAS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET
safe via BUS or NET AS-i 3.0 Gateways, safe via NET or BUS safe and Safe Link in one device up to 450 devices 2 / 1 Master, NET / BUS Slave AS-i Safety input slaves report via safe AS-i Safety output slaves
More informationPreset Counter signo 721
Most simple handling Impressive, clearly readable display in 48x48 mm Input frequency up to 60 khz Easy installation due to pluggable terminals TECHNICAL DATA GENERAL Display Height of digits Supply voltage
More informationRosemount 333 HART Tri-Loop
Product Data Sheet Rosemount 333 Rosemount 333 HART Tri-Loop HART-TO-ANALOG SIGNAL CONVERTER Convert a digital HART signal into three additional analog signals Easy to configure and install Accessory product
More informationSet for Profibus DPV1 in IP20 TI-BL20-DPV1-8
Type code Ident no. 1545007 Number of channels 8 Dimensions (W x L x H) 110.3 x 128.9 x 74.4 mm Cable max. 50 m between interface and read/write head 2 decimal rotary coding switches for the adjustment
More informationdeltadue series gateways: PROFIBUS DP, DeviceNet, CANopen, Modbus TCP to Modbus RTU
BT. 02.30 DXDY/E deltadue series gateways: PROFIBUS DP, DeviceNet, CANopen, TCP to Integrate Ascon instrumentation lines into your system DX 5000 RS232/ Line converter / Repeater / Line adapter Data transfer
More informationSINEAX U553 Transducer for AC Voltage
With power supply RMS value measurement Carrying rail housing P/0 Application he transducer SINEAX U55 (Fig. ) converts a sinusoidal or a distorted AC voltage into a load independent DC current or a load
More informationProduct and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.
Product and Applications Description The power supply units N 125/x2 can supply DC 24 V power from an additional pair of terminals (yellowwhite). This DC 24 V output voltage can be used to power e.g. an
More informationImageFTP Visualization Software Version 3.51
OPERATING INSTRUCTIONS Visualization Software Version 3.51 FTP server for viewing and automatical saving images generated by ICR880/890 Camera Systems Contents Described Software Versions Software/ Tool
More informationMLC 9000+ TM Maximum Productivity and Versatility for Control without Compromise!
Data Sheet Maximum Productivity and Versatility for Control without Compromise! Basic Bus Communication Module DESCRIPTION The Basic Bus Communication Module (BCM) is part of the MLC 9000+ DIN rail mount
More informationProduct Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP
Product Information Gateway For Connecting EnDat Encoders to PROFIBUS-DP April 2012 PROFIBUS Gateway For Connecting EnDat Encoders Encoders with EnDat interface for connection via gateway All absolute
More informationAS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor
AS-i 3.0 Gateways AS-i 3.0 Gateways 2 / 1 AS-i Master, Slave 1 AS-i Safety Monitor for 2 s Operation using a single Monitor! Monitor processes safety slaves on two s Coupling between the two networks superfluous
More informationW 2: Subminiature photoelectric switch series: extremely small and extremely strong
Photoelectric proximity switches BGS Photoelectric proximity switches energetic, (V optics) Photoelectric reflex switches Through-beam photoelectric switches W : Subminiature photoelectric switch series:
More informationProcess modules Digital input PMI for 24 V DC inputs for 120 V AC inputs
E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation
More informationElectronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
More informationThree-phase monitoring relay CM-PFE
Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics
More informationElectronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
More informationCPU systron S 200 - S 250 - S 250c. systron S 200 - S 250 - S 250c. CPUs to the process modules. Stand-alone PLC
E031019 000823 systron S 200 - S 250 - S 250c CPU systron S 200 - S 250 - S 250c 45 mm width Flexible and expandable Easy to use software for bus connection (S 250/ S 250c) CPUs to the process modules
More informationRosemount 333 HART Tri-Loop
Product Data Sheet September 2014 00813-0100-4754, Rev GA Rosemount 333 HART Tri-Loop HART-to-Analog Signal Converter Convert a digital HART signal into three additional analog signals Easy to configure
More informationTechnical Data. Dimensions
0102 Model Number Features Comfort series 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications
More informationThe Right Tool at the Right Time. Gängtapp och borrset. enligt DIN- och ISO-standard
The Right Tool at the Right Time Gängtapp och borrset enligt DIN- och ISO-standard L113 Kombinerad Borr - Gängtappssats ISO Kierretapit/ porat, sarjat ISO ISO Tap-Drill Set ISO Maschi e Punte, Set Gjengetapper/
More informationSTEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: 2868567. DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase
Extract from the online catalog STEP-PS/1AC/12DC/1.5 Order No.: 2868567 DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase Commercial data EAN 4046356292924 Pack 1 pcs. Customs tariff
More informationOPERATING INSTRUCTIONS S300. Safety laser scanner
OPERATING INSTRUCTIONS Safety laser scanner en Operating instructions This document is protected by the law of copyright, whereby all rights established therein remain with the company SICK AG. Reproduction
More informationHandheld portable appliance testers
PAT100 SERIES Handheld portable appliance testers PAT100 SERIES Handheld portable appliance testers Simple Tick/Cross, pass/fail indication plus measurement Battery powered with rechargeable options Includes
More informationType: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
More informationContact expansion modules
Gertebild ][Bildunterschrift Kontakterweiterungen Contact for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs: 4 safety contacts
More informationPCS0100en 02.2008. Persy Control Services B.V. Netherlands
P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for
More informationABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x.16.2.1, 2CDG1101xxR0011
Technical Data 2CDC505051D0205 ABB i-bus KNX Product description Switch Actuators SA/S x.16.2.1, 16 A are modular installation devices in ProM design for installation in the distribution board. They are
More informationAnalog signal converters CC-E I/I Current / current isolators
ata sheet Analog signal converters CC-E I/I Current / current isolators The CC-E I/I is an isolator for the electrical isolation of current signals without auxiliary supply. It allows the isolation between
More informationJabra SOLEMATE USER MANUAL
Jabra SOLEMATE USER MANUAL Contents Welcome...2 JABRA Solemate OVERVIEW...3 connecting...6 play music, chat and voice guidance...8 support... 12 technical specifications... 16 1 WELCOME Thank you for purchasing
More informationM-series Virtual I/O Module 2
DeltaV Distributed Control System Product Data Sheet M-series Virtual I/O Module 2 Non-intrusive DeltaV I/O simulation Powerful integration solution Easy to use Modular, flexible packaging The M-series
More informationSpeed sensor MiniCoder GEL 247
Speed sensor MiniCoder GEL 47 Flange assembly Technical information version 08.0 The MiniCoder family from Lenord + Bauer offers spacesaving solutions for the contactless measurement of rotational movements
More informationBar Code Reader Series BCL 20 A flexible reader for a variety of applications
Bar Code Reader Series BCL 20 A flexible reader for a variety of applications PRODUCT INFORMATION The benchmark for flexibility. Laser scanners of the BCL 20 series as variable as your requirements demand.
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 15 mm
0102 Model Number Features Comfort series 15 mm flush Accessories MHW 01 Modular mounting bracket MH 04-2057B Mounting aid for VariKont and +U1+ Technical Data General specifications Switching element
More informationContact expander modules
Gertebild ][Bildunterschrift Kontakterweiterungen Contact expansion module for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs:
More informationPHOENIX CONTACT - 2012-12-14. Features
Electronic monitoring relay for phase sequence, phase failure, and asymmetry monitoring Data sheet 101748_en_03 1 Description PHOEIX COTACT - 2012-12-14 Features Increasingly higher demands are being placed
More information1788 Linking Device Specifications
Technical Data 1788 Linking Device Specifications Catalog Numbers 1788-EN2DNROM, 1788-EN2DNR, 1788-EN2FFR, 1788-EN2PAR, 1788-CN2DN, 1788-CN2FFR, 1788-CN2PAR, 1788-FBJB4R, 1788-FBJB6 Topic Page 1788-EN2DNR
More informationAccuracy counts! SENSORS WITH ANALOG OUTPUT
Accuracy counts! SENSORS WITH ANALOG OUTPUT OTHER APPLICATIONS: KEY ADVANTAGES: Distance measurement Positioning Profile detection Deformation monitoring Vibration monitoring Process monitoring Detection
More informationCLV620, CLV630, CLV640: Intelligence for logistics and automation.
P R O D U C T I N F O R M AT I O N CLV620, CLV630, CLV640: Intelligence for logistics and automation. A new generation of bar code scanners with high reading and network performance. Greater speed for
More informationNX safety stand-alone
NX-S@ NX safety stand-alone stand-alone into machine automation Expandable safety system up to 32 safety connections or 63 standard connections controller flexible system lets your freely mix safety I/O
More informationSEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use
s 5 146 Synco 200 Signal Converter SEZ220 With preprogrammed standard applications Freely programmable enu-driven operation Use The signal converter is for use in HVAC plant to provide minimum / maximum
More informationMICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features
Central 48 V DC Power Supplies for PoE-Components MICROSENS Description Active network equipment which is supporting the Power-over-Ethernet functions, typically requires a powerful 48 V DC power supply.
More information2D Code Scanning Systems. Responding to the Challenges of the Future
P r o d u c t I n f o r m at i o n 2D Code Scanning Systems Responding to the Challenges of the Future The perfect solution for your 2D code detection requirements. The ideal partner for trade and industry.
More informationProgrammable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8
CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps LEDs for display of supply voltage, group and bus errors as well as status and diagnostics Connection
More informationAutomation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
More informationHSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000.
NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24
More informationOPERATING INSTRUCTIONS S3000. Safety laser scanner
OPERATING INSTRUCTIONS Safety laser scanner en Operating instructions This document is protected by the law of copyright, whereby all rights established therein remain with the company SICK AG. Reproduction
More informationFrequency Converter Fv
2 Bosch Rexroth AG Electric Drives and Controls Documentation Brake chopper with up to 30 kw continuous braking power Easy to operate and service (detachable fan, LCD operating panel with copy function)
More information1.5 GHz Active Probe TAP1500 Datasheet
1.5 GHz Active Probe TAP1500 Datasheet Easy to use Connects directly to oscilloscopes with the TekVPI probe interface Provides automatic units scaling and readout on the oscilloscope display Easy access
More informationHP 2530 8-Port Switches Quick Setup Guide
HP 2530 8-Port Switches Quick Setup Guide The switch drawings in this document are for illustration only and may not match your particular switch model. For more detailed instructions and information to
More informationRedundancy Module QUINT-DIODE/40
Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping
More informationDimensional drawing. Connection type IME08-1B5NOZT0S IME08-1B5NSZT0S IME08-1B5POZT0S IME08-1B5PSZT0S. 3 x 0.14 mm². brn. L+ Schließer/ Öffner M.
Inductive sensor, IE series, IE08, DC-wire, Standard series, Flush Inductive sensor Sensing range.5 mm Short-circuit protection (pulsed) Dimensional drawing 8x Robust brass housing, nickelplated with fine
More informationPositive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
More informationProduct and functional description
Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected
More informationPlug-in relays Mini ISO relays
Powertrain Systems Chassis Systems Safety Security Body Driver Information Convenience Description Features Limiting continuous current 70 A Dimensional characteristics and the functional allocation of
More information