Thermocouple Conversion Module
|
|
- Agnes Green
- 7 years ago
- Views:
Transcription
1 No.SS (Rev. 1) SystempaK (Digital/Single Case) Thermocouple Conversion Module Model J-STP 90/95 Introduction The Thermocouple Conversion (J-STP) Module is a signal conversion module housed in a single case and accepts an electromotive force of thermocouple input, and converts it into a 1 to 5V DC or 4 to 20 ma DC signal. The Thermocouple Conversion Module provides a linearization function as a standard function to obtain a linear output proportional to the measured temperature, as well as a filter function to convert input and output signals in response to the application. The J-STP is available for one-output (J-SMP90) or two-output (J- SMP95) model. Kind of thermocouple, range, filter function changes, and such other setting changes are easily done with the dedicated Loader Software, which operates on a general-purpose PC. Complete isolation is employed between the power, input, and output circuits. In the two-output model, isolation is employed also between the two output circuits. Specification Input signal: Thermocouples Types R, S, B, K, E, J, T, N (IEC / JIS C ) WRe5-26 (ASTM-E (2002)) Measuring range: T/C type Measuring range R -50 to 1760 S -50 to 1760 B 0 to 1820 K -200 to 1370 E -200 to 1000 J -210 to 1200 T -200 to 400 N -270 to 1300 WRe to 2700 ±120% settable Span: Specifiable to a desired span within the measuring range. Contact us for ranges less than (Because thermocouple electromotive changes are extremely small.) Burnout protection: Upscale/Downscale (Specify when ordering.) Burnout response: 30 sec or less (Moving average available, first-order lag filtering: 0.1 sec) Output signal: No. 1 output; 1 to 5V DC or 4 to 20 ma DC No. 2 output; 1 to 5V DC (Between No. 1 and No. 2 outputs is isolated.) Edge connector output; 1 to 5V DC (No. 1 output must be 1 to 5V DC when connecting the signal with the A-MC I/O cable.) Output impedance: Voltage output; 250 Ω or less, Current output; 250 kω or more Output range: -20 to +120%FS Allowable load resistance:0 to 600 Ω (Current output: Up to +110%) Output update interval: 5 msec (Output hardware filter: 0 to 90% response, 50 msec) Input/output response: 160 msec at minimum, 0 to 90% response (Moving average and first-order lag filtering are not provided.) Accuracy: Input span No. 1 and No. 2 output 10 mv or more ±0.15%FS less than 10 mv Input accuracy shown in separate table + CJC accuracy Cold junction compensation accuracy; ±0.5 at 23 (Other than R, WRe) ±1.0 at 23 (R, WRe) Insulation resistance: 500V DC, 100 MΩ min (Mutual between input - output - GND - power terminal) Withstand voltage: 1000V AC, 1 min (Mutual between input - output - GND - power terminal) +10 Power supply: 24V DC -15% Current consumption: 130 ma or less (at 24V DC) Ambient temperature: Normal operating condition; 5 to 45 Operation limit; 0 to 50 Ambient humidity: 0 to 90%RH (No condensation allowed) Mounting: Panel, Wall, DIN rail mounting Front mask color: Black Weight: 400 g Operating influence: Cold junction compensation accuracy;±0.5 /10, 5 to Supply voltage effect; ±0.1%FS/24V DC -15 % Temperature effect; Input accuracy shown in separate table/10 1
2 Loader settings: Module ID; 16 one-byte characters, 8 two-byte kanji characters Input type; Specify thermocouple type. Unit of temperature;, F Input range; Lo and Hi setting values Linearization table; 101 points Input filtering; Disabled/Enabled (moving average) Zero-span adjustment; Adjustable between -20 and +120%FS First-lag filtering; Without/With (0 to 20.0 sec, 63% response time) Note: Burnout protection (Upscale/Downscale) is specified by hardware. Please specify it when ordering. Default setting is Upscale unless specified otherwise. 2
3 Table Input Accuracy Thermocouple Full-scale set Input accuracy % to span temperature K 250 or more ±0.15% Measurement full-scale set temperature [ ] / Set span range [ ] Less than 250 ±0.15% 250 / Set span range [ ] J 200 or more ±0.15% Measurement full-scale set temperature [ ] / Set span range [ ] Less than 200 ±0.15% 200 / Set span range [ ] T 250 or more ±0.15% Measurement full-scale set temperature [ ] / Set span range [ ] Less than 250 ±0.15% 250 / Set span range [ ] E 200 or more ±0.15% Measurement full-scale set temperature [ ] / Set span range [ ] Less than 200 ±0.15% 200 / Set span range [ ] R 1000 or more ±0.15% Measurement full-scale set temperature [ ] / Set span range [ ] (Measurement value less than 500 is not applied with the accuracy specification) Less than 1000 ±0.15% 1000 / Set span range [ ] (Measurement value less than 500 is not applied with the accuracy specification) WRe5-26 ±0.15% Measurement full-scale set temperature [ ] / Set span range [ ] CJC accuracy CJC base accuracy (Measurement value less than 700 is not applied with the accuracy specification) Additional accuracy Other than R, WRe ±0.5 (at 23 ) CJC temperature effect ±0.5 / 10, 5 to 45 R, WRe ±1.0 (at 23 ) CJC temperature effect ±0.5 / 10, 5 to 45 PC loader Communication connector Thermocouple + - Burnout circuit Analog input processing circuit Digital processing section Isolation circuit Isolation circuit No.1 output circuit No.2 output circuit CJC sensor CJC Cold junction compensation temperature detection circuit Power circuit Figure 1. Functional block diagram of thermocouple conversion module 3
4 Model Number Table One-output model Basic model number Selections Additions Description I II I J-STP90 Thermocouple Conversion Module (1-output) X No varnish coated C Varnish coated -T Input signal: Thermocouple (Type T) -J Input signal: Thermocouple (Type J) -K nput signal: Thermocouple (Type K) -E Input signal: Thermocouple (Type E) -R Input signal: Thermocouple (Type R) -S Input signal: Thermocouple (Type S) -B Input signal: Thermocouple (Type B) -N Input signal: Thermocouple (Type N) 1 Output signal: 1 to 5V DC 2 Output signal: 4 to 20 ma DC -0 Without test report -1 With test report Two-output model Basic model number Selections Additions Description I II I Thermocouple Conversion Module (2-output) No varnish coated Varnish coated Input signal: Thermocouple (Type T) Input signal: Thermocouple (Type J) Input signal: Thermocouple (Type K) Input signal: Thermocouple (Type E) Input signal: Thermocouple (Type R) Input signal: Thermocouple (Type S) Input signal: Thermocouple (Type B) Input signal: Thermocouple (Type N) No. 1 output signal: 1 to 5V DC, No. 2 output signal: 1 to 5V DC No. 1 output signal: 4 to 20 ma DC, No. 2 output signal: 1 to 5V DC Without test report With test report Example: J-STP95X-J1-1 4
5 5
6 (standard accesary) (standard accesary) 6
7 MEMO 7
8 Note: Thermocouple Types S, B, and N will become available for sale at timings that differ from those of other types. When ordering, please check with our sales representative. When ordering, please specify: 1) Tag number 2) Input range* [Default setting differs depending on thermocouple type.] 3) Burnout (Upscale, Downscale) [Set to Upscale by default] The following are also set by default: a) Input filtering: Moving average available b) First-order lag filtering: Available, 0.1 sec * Use the quick list below when specifying the range. Ranges other than those below are also accepted. Code No. Input range 01 0 to to to to to to to to to to nd edition: Jan
Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM
Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES AC averaging technique used to rectify, amplify, and filter 50 Hz to 400 Hz sine-wave signals. Accepts inputs of between 20 mv to 550 V rms to give
More informationRISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
More informationJ TB/TW Temperature limiter, temperature monitor
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net
More informationAdjustment functions for both span and shift have been incorporated
SENSORS FOR SERIES LED Type Wafer Alignment Sensor FX-0-F FT-F9 FD-F7 EX-F70/F60 M SH-7 FD-L4 M-DW The use of a safe LED light beam now allows for high precision detection with a resolution of 0!m (.8
More informationMLC 9000+ TM Maximum Productivity and Versatility for Control without Compromise!
Data Sheet Maximum Productivity and Versatility for Control without Compromise! Basic Bus Communication Module DESCRIPTION The Basic Bus Communication Module (BCM) is part of the MLC 9000+ DIN rail mount
More informationContents. Document information
User Manual Contents Document information... 2 Introduction... 3 Warnings... 3 Manufacturer... 3 Description... Installation... Configuration... Troubleshooting...11 Technical data...12 Device Scope: PCB
More informationJNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
More informationDuct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
More informationHSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000.
NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24
More informationAuto-tune PID. Temperature Controller BRAINCHILD FEATURES
Auto-tune PID Temperature Controller FEATURES Easy-to-use Fuzzy modified PID heat & cool control Fast A-D sampling rate (5 times/s) Universal input (PT100, thermocouple) with high accuracy 18-bit A-D Analog
More informationTLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR
TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR TECHNICAL DATA CARATTERISTICHE MECCANICHE Housing Self-extinguishing plastic, UL 94 V0 Dimensions 48x48 mm DIN depth 98 mm Weight 225 g approx.
More informationDifferential Pressure Sensors for air and non-corrosive gases, with calibration certificate
1 919 1919P01 1919P03 QBM65/C, QBM75-1U/C Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate QBM751-1/C QBM65/C QBM75/C Highly accurate measurements with calibration
More informationVario-Series Accessories
Accessories and spare parts for GMW analogue panel meters and controllers Current Transformers pages 2-9 Shunt Resistors 10-11 Voltage Dividers 12 Power supply for indicator/controllers 13 Blanking Plates
More informationProcess modules Digital input PMI for 24 V DC inputs for 120 V AC inputs
E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation
More informationMILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)
MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed
More informationJUMPFLEX 857 Series. 0...20 ma 2...10 V. 4...20 ma. Transducers / Relay and Optocoupler Modules
0888-0172/0002-3601 JUMPFLEX 857 Series 2.0 E 12/08 Printed in Germany Subject to design changes 2...10 V 0...20 ma 4...20 ma WAGO Kontakttechnik GmbH & Co. KG Postfach 2880 32385 Minden Hansastraße 27
More informationModel: DC-A2IO Advanced HVAC Controller
Model: DC-A2IO Advanced HVAC Controller Job Name: Schedule Reference: Date: DC-A2IO Advanced HVAC Controller Package PAC-IF01 M-Net Adapter AL2-14MR-D α2 Simple Application Controller Accessories AL2-2DA
More informationH/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.
Application : The transducer RISH CON - CA/CV (Fig.1) converts a sinusoidal AC Current or AC Voltage into a load independent DC Current or a load independent DC Voltage proportional to the measured value.
More informationDigital Pressure Measuring Instrument MDR480
Description The digital panel instrument MDR480 is designed to measure, display, and monitor pressures in industrial applications. The instrument is panel mounted with a front frame dimension of 96 mm
More informationCPA PC-Programmable Current/Voltage and RTD/Thermocouple Limit Alarm Trips
January 2014 Description The universal CPA PC-Programmable Alarms provide on/off control, warn of unwanted process conditions, and provide emergency shutdown. Very economical, they accept a direct signal
More information3500/62 Process Variable Monitor
3500/62 Process Variable Monitor Description The 3500/62 Process Variable Monitor is a 6-channel monitor for processing machine critical parameters (pressures, flows, temperatures, levels, etc.) that merit
More informationCurrent valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
More informationDeltaV S-series Traditional I/O
DeltaV Distributed Control System Product Data Sheet DeltaV S-series Traditional I/O Modular and flexible construction. Reduced installation time and expense. Easy online expansion. Field mounted capable
More informationUSB TC-08. Temperature Logger. User's Guide. usbtc08.en r7 Copyright 2005-2013 Pico Technology Limited. All rights reserved.
USB TC-08 Temperature Logger User's Guide USB TC-08 User's Guide I Contents 1 Introduction...1...1 1 Overview...1 2 Leg al information...2 3 Safety warning...3 4 Company details 2 Getting Started...4...4
More information2/8.10.01. These vacuum switches are used in measuring ranges between -1 and 0 bar.
CATALOGUE > Release 8.5 > Electronic vacuum switches Series SWM Electronic miniature vacuum switches Series SWM These vacuum switches are used in measuring ranges between -1 and 0 bar. Small dimension
More informationMCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet 100260_en_01. 1 Description
Voltage Transducer for DC Voltages TERFACE Data Sheet 000_en_0 PHOENIX CONTACT - /00 Description The MCR voltage transducer measures DC voltages in several signal ranges from 0... ±0 V DC to 0... ±0 V
More informationMeter Relays. 077 Series Analogue Meter Relays. Features. Applications
077 Series Analogue Features Monitors and controls any variable which can be converted to an A.C. or D.C. signal. Rugged, shock and vibration resistant design Indicator, relays and power unit in one housing
More informationEXTERNAL DIMENSIONS AND PARTS
FX2N-4DA SPECIAL FUNCTION BLOCK USER S GUIDE JY992D65901A This manual contains text, diagrams and explanations which will guide the reader in the correct installation and operation of the FX2N-4DA special
More informationDS 600. A contact free flux gate based current measurement sensor 600A rms
DS 600 A contact free flux gate based current measurement sensor 600A rms DS 600 is member of the small housing sensor family. The family includes a 200A and a 600A version. 600A rms - 900A peak Maximum
More informationTHERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES
TSI and TSI logo are registered trademarks of TSI Incorporated. SmartTune is a trademark of TSI Incorporated. THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES IFA 300 Constant Temperature Anemometry
More informationTemp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol
Temp-485-Pt100 A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol Temp-485-Pt100 Box version [600 113] Temp-485-Pt100 Cable version [600 114]
More informationVOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421
VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421 TABLE OF CONTENTS 1. FEATURES... 1 2. SPECIFICATIONS... 1 2-1 General Specifications...1 2-2 Electrical Specifications... 2 3. FRONT PANEL DESCRIPTION... 4 3-1
More informationHARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel. +45 7547 0600 vc@valcontrols.com www.valcontrols.
HARDWARE MANUAL Ixx24-A 1/20 Table of contents 1 General... 3 1.1 Safety instructions... 3 1.2 Environment... 3 1.3 Mounting and dimension... 3 2 Communication... 4 2.1 Control loop AI0 and Transmitter
More informationModel CS 64 Mini-DIN Cable and Adaptor
Model CS 64 Mini-DIN Cable and Adaptor Page 1 of 9 Features Hi-Pro and NOAHlink compatible cable & Mini-DIN CS 64 Clip Module / NOAHlink Adaptor #1 Integrated Clip Module - Mini-DIN Cable Integrated NOAHlink
More information1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.
1587/1577 Insulation Multimeters Technical Data Two powerful tools in one. The Fluke 1587 and 1577 Insulation Multimeters combine a digital insulation tester with a full-featured, true-rms digital multimeter
More informationSINEAX U553 Transducer for AC Voltage
With power supply RMS value measurement Carrying rail housing P/0 Application he transducer SINEAX U55 (Fig. ) converts a sinusoidal or a distorted AC voltage into a load independent DC current or a load
More informationCross-beam scanning system to detect slim objects. 100 mm 3.937 in
891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC
More informationADC-20/ADC-24 Terminal Board. User Guide DO117-5
ADC-20/ADC-24 Terminal Board User Guide DO117-5 Issues: 1) 8.11.05 Created by JB. 2) 13.12.05 p10: added 0V connection to thermocouple schematic. 3) 22.3.06 p11: removed C1. 4) 20.8.07 New logo. 5) 29.9.08
More informationHow To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)
transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control
More informationSmart DeviceNet Remote I/O Terminals
Smart DeviceNet Remote I/O Terminals ather and Use Information for Effective Preventive Maintenance et more useful data for preventive maintenance when you build cost-effective parallel information systems
More informationIncremental Rotary Encoder E6B2
Incremental Rotary Encoder General-Purpose Rotary Encoder Withstands arge Shaft oads Wide variety of supply voltages and output forms Easy-to-adjust zero index (phase Z) with origin indicating function
More informationVoltage Regulator SPAU 341 C. Product Guide
Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations
More informationWahl C50 Calibrator FEATURES
NEW! On Site Multifunction Portable Far Superior Accuracy as Compared to Fluke! Simultaneous Measurement and Generation Quick Connect Terminals Anti-Shock Boot Quick Connect Terminals Navigator Power Supply,
More informationData sheet GIOD.1 Input/output module with CAN bus. ERP no.: 5204183. www.guentner.de. Data sheet GIOD.1 V_3.0
Data sheet GIOD.1 Input/output module with CAN bus ERP no.: 5204183 www.guentner.de Page 2 / 10 Contents 1 GIOD.1... 3 1.1 Functional description...3 1.2 Connections... 5 1.3 Electrical properties of...
More informationMAXIMUM LOAD CURRENT 1 A SN SERIES
SOLID STATE RELAY (I/O Module) MAXIMUM LOAD CURRENT 1 A SN SERIES RoHS compliant FEATURES I/O modules for interface between CPU and external input devices or loads Ultra slim and light weight, SIL s type
More informationDC Electronic Loads 8500 series
Data Sheet DC Electronic Loads 8500 series 2400W 600 W - 1200 W 300 W Versatile & Economical DC Electronic Loads The 8500 series Programmable DC Electronic Loads can be used for testing and evaluating
More informationLM56 Dual Output Low Power Thermostat
Dual Output Low Power Thermostat General Description The LM56 is a precision low power thermostat. Two stable temperature trip points (V T1 and V T2 ) are generated by dividing down the LM56 1.250V bandgap
More informationT-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE
T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE T-Series industrial inclinometers are compact high performance sensors used to determine inclination in roll and pitch axes with excellent precision and
More informationAutomation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
More informationDisturbance Recoder SPCR 8C27. Product Guide
Issued: April 1999 Status: Updated Version: C/26.04.2006 Data subject to change without notice Features Versatile digital disturbance recorder module for recording various phenomena in the electric power
More informationRM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
More informationUSER MANUAL V5.0 ST100
GPS Vehicle Tracker USER MANUAL V5.0 ST100 Updated on 15 September 2009-1 - Contents 1 Product Overview 3 2 For Your Safety 3 3 ST100 Parameters 3 4 Getting Started 4 4.1 Hardware and Accessories 4 4.2
More information40.3. Control Relays and Timers
.3 Contents EASY500/700/800 Intelligent Relays........ EASY/MFD Expansion Modules............ MFD Intelligent Relays................... EASY/MFD Communication Modules....... EASY/MFD Power Supplies, Accessories
More informationNTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter
NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter Description: The NTE2053 is a CMOS 8 bit successive approximation Analog to Digital converter in a 20 Lead DIP type package which uses a differential
More informationSeries AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter
FEATURES: Click on Series name for product info on aimtec.com Models Single output Model Max Output Power (W) 1 AC-DC Constant Current or Constant Over temperature protection Voltage LED Driver Over current
More information713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.
and Transmitter All-in-one package for open channel flow measurement. 3.1 NEW Class 1, Division 1 Approved Sensor As our products are continuously improved, we reserve the right to make any change in the
More informationABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01
ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions
More informationSR1, SR3 Series Digital Controller Instruction Manual
SR, SR Series Digital Controller Instruction Manual Please do not begin operating this product until you have read this instruction manual thoroughly and you understand its contents. Safety Rules For matters
More informationFieldIT Head mounted Temperature Transmitter TF02/TF02-Ex
Data Sheet 0/-8.5 EN FieldIT Head mounted Temperature Transmitter TF0/TF0-Ex FOUNDATION Fieldbus H, Pt 00 (RTD), thermocouples, or independent channels Input Resistance thermometer (-, -, -wire circuit)
More informationDCS Input/Output Relay Card Series
Input/Output Relay Card Series I/O RELAY CARD (with loopback test function) 8N The 8N series I/O Relay Cards easily and quickly standardize and facilitate installation of the relay board. Loopback test
More informationFerrostat Speed Sensor Series DSF Explosion Proof Versions EEx
Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment
More informationPC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS
PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS FRANCE Head office USA 4 Rue du Bois Chêne le loup Parc d Activité de Brabois 54 500 VANDOEUVRE LES NANCY (33) 0383442413, Fax (33) 0383443797
More informationDRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters
The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual
More informationABB i-bus EIB / KNX Analogue Input AE/S 4.2
Product Manual ABB i-bus EIB / KNX Analogue Input AE/S 4.2 Intelligent Installation Systems This manual describes the functionality of Analogue Input AE/S 4.2. Subject to changes and errors excepted. Exclusion
More informationAbsolute Rotary Encoder E6CP
Absolute Rotary Encoder Absolute Rotary Encoders with Gray Code Output Gray code output decreases output errors Lightweight plastic housing Used with Omron s H8PS Cam Positioner, this encoder detects the
More informationOrdering Part Numbers: Universal Signal Converter: USC-CVB225-01 Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V
Description: The universal signal converter offers threeway isolation and translates one input control signal into one to three simultaneous outputs. Switches allow the user to select the desired input
More informationSIMATIC NET. CP 243-2 AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program
Preface Contents SIMATIC NET CP 243-2 AS-Interface Master Manual Technical Description and Installation Instructions Interface to the User Program 2 in the S7-200 CPU Access to the Data of the AS-i Slaves
More informationT0118 T2118 T3118. Instruction Manual
Programmable indoor transmitter of temperature T0118 Programmable indoor transmitter of atmospheric pressure T2118 Programmable indoor transmitter of temperature, relative humidity and other derived humidity
More information3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range.
2-Color Display High-Precision Digital Pressure Switch Series ZSE3A(F)/ISE3A RoHS Can copy to up to 1 switches simultaneously. The settings of the master sensor can be copied to the slave sensors. Reducing
More informationModular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
More informationCold-Junction-Compensated K-Thermocoupleto-Digital Converter (0 C to +1024 C)
19-2235; Rev 1; 3/02 Cold-Junction-Compensated K-Thermocoupleto-Digital General Description The performs cold-junction compensation and digitizes the signal from a type-k thermocouple. The data is output
More informationWhat Does Rail-to-Rail Operation Really Mean?
What Does Rail-to-Rail Operation Really Mean? 2004 Microchip Technology Incorporated. All Rights Reserved. What does Rail-to-Rail Operation really mean? 1 Agenda What does Rail-to-Rail output operation
More informationLM741. Single Operational Amplifier. Features. Description. Internal Block Diagram. www.fairchildsemi.com
Single Operational Amplifier www.fairchildsemi.com Features Short circuit protection Excellent temperature stability Internal frequency compensation High Input voltage range Null of offset Description
More informationAMP CO Plus Insert for Cat. 6 A Applications
Product Specification 108-93039 10/Mar/2011 Rev F AMP CO Plus Insert for Cat. 6 A Applications 1. SCOPE 1.1 Content This specification covers performance, tests and quality requirements for AMP* CO Plus
More informationABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x.16.6.1, 2CDG 110 1xx R0011
, 2CDG 110 1xx R0011 SA/S 8.16.6.1 2CDC 071 006 S0010 The 16/20 A Switch actuators are modular installation devices in Pro M Design for installation in the distribution board. The devices are especially
More informationPSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624
PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624 v.1.0 AC/AC power supply unit Edition: 1 from 24 th October 2008 Supercedes edition: ---------- 10062009 CONTENTS: 1. Technical description. 1.1. General description
More informationE8F2. Pressure Sensor with Easy-to-Read LED Display. Digital Pressure Sensor. Ordering Information. Sensors (Refer to Dimensions on page 7.
Digital Sensor CSM DS_E_4_3 Sensor with Easy-to-Read LED Display status can be checked at a glance from the digital display and bar display. Measurement pressure prevents incorrect outputs due to momentary
More informationFM Radio Transmitter & Receiver Modules
FM Radio Transmitter & Receiver Modules T5 / R5 Features MINIATURE SIL PACKAGE FULLY SHIELDED DATA RATES UP TO 128KBITS/S RANGE UPTO 300 METRES SINGLE SUPPLY VOLTAGE INDUSTRY PIN COMPATIBLE QFMT5-434 TEMP
More informationAnalog signal converters CC-E I/I Current / current isolators
ata sheet Analog signal converters CC-E I/I Current / current isolators The CC-E I/I is an isolator for the electrical isolation of current signals without auxiliary supply. It allows the isolation between
More informationSDI Multi Sensor Module with Charger Enclosure Station Support
Description The purpose of the is to provide a low power temperature compensated battery charge controller and a general-purpose interface for analog sensors. Sensor and charge controller data are acquired
More informationTemperature Controller CD401/CD901/CD701/CD501/CD100/CD101 Instruction Manual
Ⅰ. Warn Warning of connection Temperature Controller CD401/CD901/CD701/CD501/CD100/CD101 Instruction Manual If the controller fails to operate or error occurs, the system will bring fault for it, please
More informationMODEL IFMA - DIN-RAIL FREQUENCY TO ANALOG CONVERTER
Bulletin No. IFMA-E Drawing No. LP0340 Released 5/06 Tel +1 (717) 767-6511 Fax +1 (717) 764-0839 www.redlion.net MODEL IFMA - DIN-RAIL FREQUENCY TO ANALOG CONVERTER SIMPLE ON-LINE RANGE SETTING (Using
More informationADM1TE 5/30A DIN rail single phase two wire energy meter
ADMTE 5/30A DIN rail single phase two wire energy meter. Safety instruction.2 Foreword.3 Performance criteria.4 Specifications.5 Basic errors.6 Description.7 Dimensions.8 Installation.9 Operating.0 Troubleshooting.
More informationS-series Electronic Marshalling
DeltaV Distributed Control System Product Data Sheet S-series Electronic Marshalling I/O anywhere you need it Single channel granularity Reduces installed cost of system Fully redundant architecture Field
More informationQuick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
More informationM2M I/O Modules. To view all of Advantech s M2M I/O Modules, please visit www.advantech.com/products.
M2M I/O Modules 14 M2M I/O Modules Overview 14-2 M2M I/O Modules Selection Guide 14-6 ADAM-2510Z Wireless Router Node 14-8 ADAM-2520Z Wireless Modbus RTU Gateway 14-9 ADAM-2031Z ADAM-2632Z ADAM-2017Z ADAM-2018Z
More informationDigital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
More informationType: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
More informationUser's Guide. True RMS Industrial Multimeter
User's Guide 97650 True RMS Industrial Multimeter Ω C ã F ã 10A V µ 10A V ã ã ma A Introduction This meter measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency (electrical & electronic),
More informationFLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX 759 26-06-2007 759 M1 02 E MES FLOW CALCULATOR 759-02/1
BAMOPHOX 759 E - M FLOW CALCULATOR INSTRUCTION MANUAL MESURES 22, Rue de la Voie des Bans - Z.I. de la Gare - 95100 ARGENTEUIL Tél : (33) 01 30 25 83 20 - Web : www.bamo.fr Fax : (33) 01 34 10 16 05 -
More informationUMEC International Corporation
UP1301A SERIES 130 Watt Open Frame Switchers Small Size 3*5*1.2(inches) Universal Input to 264 VAC Low Power Consumption Overvoltage Protection Continuous Short Circuit Protection Over Temperature Protection
More informationDifferential Charge Amplifier
Electronics Differential Type 58A... The differential charge amplifier is used for signal conversion of piezoelectric sensors with differential output. Executions Aluminum die-cast enclosure (IP64) Plastic
More informationTemperature Transmitters ZTT series
BT.11.13 ZT/E Transmitters ZTT series The ZTT Series transmitters accept the most commonly used temperature sensors (TC and RTD), as well as mv and slidewire feedback signals. All ZTT transmitters provide
More informationResearch RF Sputtering Packages
Research RF Sputtering Packages Shown with 3" Polaris Adjustable Position Source with Tilt and Shutter 300 or 600 Watt Low Cost Packages for Those With Limited Budgets Desiring Full Capability 13.56 MHz
More informationIO-DIM6 6-Channel, Digital to Analogue Converters
Page 1 of 6 IO-DIM6 6-Channel, Digital to Analogue Converters Features: Benefits: Input status indication Calibrated output DIN Rail mounting Expands controller input capacity Fault finding LED indication
More informationMPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card
Machinery Protection Card Type FEATURES Continuous on-line Machinery Protection Card Real-time measurement and monitoring using state-of-the-art DSP techniques Fully VME-compatible slave interface Fully
More informationLow Cost, Precision IC Temperature Transducer AD592*
a FEATURES High Precalibrated Accuracy:.5 C max @ +25 C Excellent Linearity:.15 C max ( C to +7 C) Wide Operating Temperature Range: 25 C to +15 C Single Supply Operation: +4 V to +3 V Excellent Repeatability
More informationCPCI-3U-AC-300W-R. Rugged 300W AC Input 3U CompactPCI Power Supply. Electrical Specification for: Telkoor Part Number: 900-4602-0000
Electrical Specification for: CPCI-3U-AC-300W-R Rugged 300W AC Input 3U CompactPCI Power Supply Telkoor Part Number: 900-4602-0000 GENERAL SCALE RELEASE DATE 12/9/06 SHEET 1 OF 6 REVISION HISTORY Rev Level
More informationApplication Note TMA Series
1W, SIP, Single & Dual Output DC/DC Converters Features SIP Package with Industry Standard Pinout Package Dimension: 19.5 x 10.2 x 6.1 mm (0.77 x 0.4 x 0.24 ) 5V&12V Models 19.5 x 10.2 x 7.1 mm (0.77 x
More informationCQM1-SF200/CS1W-SF200
Safety Relay Unit ( I/O Unit Type) CQM1-SF200/CS1W-SF200 CSM_CQM1-SF200_CS1W-SF200_DS_E_2_1 A Safety Relay Unit That Functions as a I/O Unit. Less Installation Space and Wiring Required. Safety Relay Unit
More information