Power Distribution Units

Size: px
Start display at page:

Download "Power Distribution Units"

Transcription

1

2 Power Distribution Units Deliver, monitor and control power to your racks with our diverse PDU offering You re in control. With Electrorack s diverse PDU offering, you can choose the level of power and control you need. Whether you just want to deliver power, monitor the current draw on a local meter, have remote IP access to monitor loads and set alarm conditions or even turn individual receptacles on or off remotely from anywhere in the world, Electrorack has a solution for you! Electrorack power distribution products are designed and tested to the latest IT safety standards. Available in a wide variety of input and output connections, voltages range from 120V, 208V and 230V single and 3-phase for North American and International requirements. Electrorack s product line spans a wide range of power requirements from 1.8kW up to 21.5kw per single branch whip. And, our versatile mounting solutions include zero U vertical tool-less button mounting to ease installation while maximizing space utilization. Don t see the exact unit you need? Call us. Our flexible manufacturing allows us to create timely solutions based on your requirements. Product Highlights Multiple Power Distribution Options: 120V, 208V, 230V & 3-phase power options. 15, 20, 30, 50 & 60-Amp power input feeds to maximize whip efficiency to your load. Basic, Metered, Monitored & Switched: Match your level of access and control required for your equipment. Remote IP Access Solutions: Monitored & Switched units provide remote access to manage PDU s from anywhere. Environmental Monitoring: Monitored & Switched units can monitor & alarm temperature & humidity conditions. RMS Metering: Accuracy is critical when monitoring loads, that s why we utilize industry-leading true RMS meters. Zero U and Rack-mount models: Both vertical and horizontal unit form factors are available. Unsurpassed Mounting Flexibility: Complete offering of tool-less mounting bars and side and recessed-mount brackets allow power to mount virtually anywhere in a rack. Tested to UL : Our PDUs are tested to the latest standard for IT equipment - UL Choose the products that meet your requirements Switched Deliver Power to Equipment in a Cabinet Make informed decision at the cabinet about adding/balancing the load to prevent overload/circuit failure Remote access to identify/monitor power load issues via IP from anywhere in the world Benefit Monitor critical environmental conditions that may impact equipment performance to prevent downtime Determine your own thresholds for notification via or pager of pending power, temperature or humdity issues Turn individual receptacles on/off or reboot equipment remotely via IP from anywhere. Turn off unused receptacles to prevent unauthorized equipment connections. Style Monitored Metered Basic Power Distribution Local Current Meter on Unit Tempurature Current User-defined Humidity Monitoring via IP Alarm Thresholds Monitoring via IP Receptacle Control via IP Feature 2

3 Versatile Mounting Solutions Tool-less Mounting Utilizing buttons on the back of all vertical PDUs, we are able to offer toolless mounting. This allows users to quickly mount or remove units on our Vertical Power Mounting Bars inside the enclosure. Units slide into the keyhole slots on the power bars. Zero U Power Mounting Bars Available in widths to accommodate 1,2 or 3 vertical PDU s or a combination of PDU s and cable management rings. Vertical Power Mounting Bars can mount anywhere and are infinitely adjustable along the front to back Unistrut frame members of Electrorack enclosures. In 24 or wider enclosures the body of the PDU s do not block access to the mounting holes. Side-mount Brackets Innovative tool-less side-mount brackets allow power receptacles to face forward or backward in the rack. This orinetation keeps the plugs out of the rack space improving access to equipment mounting holes and minimizing blockage of exhaust airflow. Rack-mount Unit Flexibility Fully rotatable rack-mount ears allow units to mount in any orientation in the rack, even vertically. The recessedmount option is ideal when there is insufficient space at the front of the rack for plugs and cords. A lacing bar that spans the front of the recessed brackets is included to manage cables and keep them from sagging out of the rack space occupied by the PDU. 3 WHAT S INSIDE OVERVIEW 2-3 BASIC PDU S 4-5 METERED PDU S MONITORED PDU S SWITCHED PDU S MOUNTING ACCESSORIES POWER CORDS

4 Basic PDUs Cost-effective power delivery to the rack Basic power distribution delivers a reliable single input power source to the rack. Available in a wide variety of input and output connections, voltages range from 120V, 208V and 3-Phase to match the load required at each rack. Electrorack s Basic rack power distribution are available in Zero U vertical or 19 rack-mountable form factors and can satisfy a wide range of power requirements offering 1.8kW up to 21.5kw per single branch whip. Basic Power Distribution Basic PDU Features & Benefits Multiple Power Distribution Options: 120V, 208V & 3-phase power options. 15, 20, 30, 50 & 60-Amp power input feeds to maximize whip efficiency to your load. Zero U and Rack-mount models: Both vertical and horizontal unit form factors are available. Unsurpassed Mounting Flexibility: Complete offering of tool-less mounting bars and side and recessed-mount brackets allow power to mount virtually anywhere in a rack. Tested to UL : Our PDUs are tested to the latest standard for IT equipment - UL Branch Circuit Protection: All PDUs over 20 amps are equipped with UL489 Listed Circuit Breakers. 208V, 20A Basic PDU with C13 IEC receptacles shown in traditional 19 EIA mounting position. Units equipped with branch circuit protection as required by UL utilize UL489 Listed circuit breakers. Available in IEC (shown left) or NEMA receptacle (shown right) configurations, Basic PDUs are a cost-effective means of delivering power to multiple pieces of equipment. 120V, 20A Basic PDU with NEMA 5-20 receptacles shown at the back of the rack with the receptacles facing up. This orinetation is useful for preventing plugs from being pulled out. 4

5 Basic PDU Offering Basic Power Model Voltage Amp/kW Input Output Form Factor (LxWxD) Description PB V 15A 5-15P (10) NEMA "x1.72"x1.72" PB V 15A 5-15P (18) NEMA "x1.72"x1.72" PB V 15A 5-15P (24) NEMA "x1.72"x1.72" PB V 20A L5-20P (10) NEMA "x1.72"x1.72" PB V 20A L5-20P (18) NEMA "x1.72"x1.72" PB V 20A L5-20P (24) NEMA "x1.72"x1.72" PB V 30A L5-30P (16) NEMA "x2.18"x1.72"* PB V 30A L5-30P (24) NEMA 5-20 PB V 20A L6-20P (12) IEC-320 C "x1.72"x1.72" PB V 20A L6-20P (18) IEC-320 C "x1.72"x1.72" PB V 20A L6-20P 66.5"x1.72"x1.72" PB V 30A L6-30P (16) IEC-320 C "x2.18"x1.72"* PB V 30A L6-30P PB V 30A L6-30P (20 IEC-320 C13 (4) C19 PBD V, 3PH 5.7kW L15-20P 66.5"x2.18"x1.72" PBY V, 3PH 5.7kW L21-20P 66.5"x2.18"x1.72" PBD V, 3PH 8.6kW L15-30P PBY V, 3PH 8.6kW L21-30P PBD V, 3PH 14.4kW CS8365S PBD V, 3PH 17.3kW 460P9W PBY V, 3PH 17.3kW 560P9W Basic 17.5 Horizontal PDU, 120V 15A, (10) NEMA 5-15 outlets, 5-15P input plug. Basic 29.5 Vertical PDU, 120V 15A, (18) NEMA 5-15 outlets, 5-15P input plug. Basic 66.5 Vertical PDU, 120V 15A, (24) NEMA 5-15 outlets, 5-15P input plug. Basic 17.5 Horizontal PDU, 120V 20A, (10) NEMA 5-20 outlets, L5-20P input plug. Basic 29.5 Vertical PDU, 120V 20A, (18) NEMA 5-20 outlets, L5-20P input plug. Basic 66.5 Vertical PDU, 120V 20A, (24) NEMA 5-15 outlets, L5-20P input plug. Basic 29.5 Vertical PDU, 120V 30A, (16) NEMA 5-20 outlets, L5-30P input plug. Basic 66.5 Vertical PDU, 120V 30A, (24) NEMA 5-20 outlets, L5-30P input plug. Basic 17.5 Horizontal PDU, 208V 20A, (12) C13 outlets, L6-20P input plug w/10' cord. Basic 29.5 Vertical PDU, 208V 20A, (18) C13 outlets, L6-20P input plug w/10' cord. Basic 66.5 Vertical PDU, 208V 20A, (24) C13 outlets, L6-20P input plug w/10' cord. Basic 29.5" Vertical PDU, 208V 30A, (16) C13 outlets, L6-30P input plug w/10' cord. Basic 66.5" Vertical PDU, 208V 30A, (24) C13 outlets, L6-30P input plug w/10' cord. Basic 66.5" Vertical PDU, 208V 30A, (20) C13 & (4) C19 outlets, L6-30P input plug w/10' cord. Basic 66.5" Vertical PDU, 3PH Delta 208V 20A, (24) C13 outlets, L15-20P input plug w/10' cord. Basic 66.5" Vertical PDU, 3PH Wye 208V 20A, (24) C13 outlets, L21-20P input plug w/10' cord. Basic 66.5 Vertical PDU, 3PH Delta 208V 30A, (24) C13 & (6) C19 outlets, L15-30P input plug w/10' cord. Basic 66.5 Vertical PDU, 3PH Wye 208V 30A, (24) C13 & (6) C19 outlets, L21-30P input plug w/10' cord. Basic 66.5 Vertical PDU, 3PH Delta 208V 50A, (24) C13 & (6) C19 outlets, CS8365C input plug w/10' cord. Basic 66.5 Vertical PDU, 3PH Delta 208V 60A, (24) C13 & (6) C19 outlets, 460P9W input plug w/10' cord. Basic 66.5 Vertical PDU, 3PH Wye 208V 60A, (24) C13 & (6) C19 outlets, 560P9W input plug w/10' cord. Basic Power Distribution * Body of housing is 1.72 deep except at the breaker box where it is 3.5 deep. All units are approved to UL If your requirements fall outside of the standard offering above, ask Electrorack. Our capabilities allow us to create a wide range of offerings that extend beyond the standard listing above. 5

6 Metered PDUs Monitor current draw at the PDU via local meter Metered power distribution units deliver a single input power source to the rack with the added ability to monitor aggregate current (amps). Utilizing True RMS meters, the aggregate current draw per circuit is displayed on the unit via a digital display. The local digital display in the rack helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the power distribution unit (PDU). This data can be used to forecast future power capacity planning, facility enhancements and cooling requirements. Metered PDU Features & Benefits Metered Power Distribution Input Current Monitoring: Precisely measure the aggregate current draw (in amps) on each power circuit utilizing a true RMS meter to avoid overloading circuits. On-site verification of the current draw via the LED digital display. Multiple Power Distribution Options: 120V, 208V & 3-phase power options. 15, 20, 30, 50 & 60-Amp power input feeds to maximize whip efficiency to your load. Zero U and Rack-mount models: Both vertical and horizontal unit form factors are available. Unsurpassed Mounting Flexibility: Complete offering of tool-less mounting bars and side and recessed-mount brackets allow power to mount virtually anywhere in a rack. Tested to UL : Our PDUs are tested to the latest standard for IT equipment - UL Branch Circuit Protection: All PDUs over 20 amps are equipped with UL489 Listed Circuit Breakers. 120V, 20A Metered PDU with NEMA 5-20 receptacles shown rmounted vertically to the equipment mounting angle utilizing the rotatable mounting brackets. True RMS local meters on the PDU provide accurate current measurements to quickly identify remaining capacity, allowing for informed decisions about adding additional equipment. Two 120V, 20A Metered PDUs mounted on the outer-most positions of a 6.8 wide vertical mounting bar allowing cable rings to mount in the center position. 120V, 20A Basic PDU with NEMA 5-20 receptacles shown mounted with the recessed rack-mounting bracket. The bracket includes cable lances for lacing and strain relief. 6

7 Metered PDU Offering Metered Power Model Voltage Amp/kW Input Output Form Factor (LxWxD) Description PM V 20A L5-20P (10) NEMA "x1.72"x1.72" PM V 20A L5-20P (18) NEMA "x1.72"x1.72" PM V 20A L5-20P (24) NEMA "x1.72"x1.72" PM V 30A L5-30P (16) NEMA "x2.18"x1.72"* PM V 30A L5-30P (24) NEMA 5-20 PM V 20A L6-20P (12) IEC-320 C "x1.72"x1.72" PM V 20A L6-20P (18) IEC-320 C "x1.72"x1.72" PM V 20A L6-20P 66.5"x1.72"x1.72" PM V 30A L6-30P (16) IEC-320 C "x2.18"x1.72"* PM V 30A L6-30P PM V 30A L6-30P PMD V, 3PH 5.7kW L15-20P 66.5"x2.18"x1.72" PMY V, 3PH 5.7kW L21-20P 66.5"x2.18"x1.72" PMD V, 3PH 8.6kW L15-30P PMY V, 3PH 8.6kW L21-30P PMD V, 3PH 14.4kW CS8365S PMD V, 3PH 17.3kW 460P9W PMY V, 3PH 17.3kW 560P9W * Body of housing is 1.72 deep except at the breaker box where it is 3.5 deep. Metered 17.5" Horizontal PDU, 120V 20A, (10) NEMA 5-20 outlets, L5-20P input plug w/10' cord. Metered 29.5" Vertical PDU, 120V 20A, (18) NEMA 5-20 outlets, L5-20P input plug w/10' cord. Metered 66.5" Vertical PDU, 120V 20A, (24) NEMA 5-15 outlets, L5-20P input plug w/10' cord. Metered 29.5" Vertical PDU, 120V 30A, (16) NEMA 5-20 outlets, L5-30P input plug w/10' cord. Metered 66.5" Vertical PDU, 120V 30A, (24) NEMA 5-20 outlets, L5-30P input plug w/10' cord. Metered 17.5" Horizontal PDU, 208V 20A, (12) C13 outlets, L6-20P input plug w/10' cord. Metered 29.5" Vertical PDU, 208V 20A, (18) C13 outlets, L6-20P input plug w/10' cord. Metered 66.5" Vertical PDU, 208V 20A, (24) C13 outlets, L6-20P input plug w/10' cord. Metered 29.5" Vertical PDU, 208V 30A, (16) C13 outlets, L6-30P input plug w/10' cord. Metered 66.5" Vertical PDU, 208V 30A, (24) C13 outlets, L6-30P input plug w/10' cord. Metered 66.5" Vertical PDU, 208V 30A, (20) C13 & (4) C19 outlets, L6-30P input plug w/10' cord. Metered 66.5" Vertical PDU, 3PH Delta 208V 20A, (24) C13 & (6) C19 outlets, (3) Meters, L15-20P input plug w/10' cord. Metered 66.5" Vertical PDU, 3PH Wye 208V 20A, (24) C13 & (6) C19 outlets, (3) Meters, L21-20P input plug w/10' cord. Metered 66.5" Vertical PDU, 3PH Delta 208V 30A, (24) C13 & (6) C19 outlets, (3) Meters, L15-30P input plug w/10' cord. Metered 66.5" Vertical PDU, 3PH Wye 208V 30A, (24) C13 & (6) C19 outlets, (3) Meters, L21-30P input plug w/10' cord. Metered 66.5" Vertical PDU, 3PH Delta 208V 50A, (24) C13 & (6) C19 outlets, (3) Meters, CS8365C input plug w/10' cord. Metered 66.5" Vertical PDU, 3PH Delta 208V 60A, (24) C13 & (6) C19 outlets, (3) Meters, 460P9W input plug w/10' cord. Metered 66.5" Vertical PDU, 3PH Wye 208V 60A, (24) C13 & (6) C19 outlets, (3) Meters, 560P9W input plug w/10' cord. Metered Power Distribution All units are approved to UL Meters utilize RMS (root mean square) method for the most accurate amperage calculation. All 3 Phase PDU s utilize a separate meter on each branch for easy load balancing. If your requirements fall outside of the standard offering above, ask Electrorack. Our capabilities allow us to create a wide range of offerings that extend beyond the standard listing above. 7

8 Monitored PDUs Monitor your power from anywhere via IP access Monitored Power Distribution Monitored power distribution by Electrorack delivers power to the rack with the added ability to monitor aggregate current (amps), temperature and humidity via internet protocol (IP). The aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the power distribution unit (PDU). IP access to the PDU allows the network operations center (NOC) to monitor power usage remotely via the industries most user-friendly web interface. Remote Monitoring features include 10/100 BaseT Ethernet interface for SSL Web, SSH, Telnet, & SNMP control; outlet grouping on different power circuits; console port access to remote servers, routers and network equipment. Monitored PDU Features & Benefits Input Current Monitoring: Precisely measure the aggregate current draw (in amps) on each power circuit utilizing a true RMS meter to avoid overloading circuits. On-site verification of the input current with the LED digital display. Remote verification via browser or serial screen. Multiple Power Distribution Options: 120V, 208V & 3-phase power options. Available in 20 & 30-Amp power input feeds to maximize whip efficiency to your load. Single or Dual Circuit Options: Single or Dual input feeds with varying receptacle styles and densities. Dual feed units cost-effectively deliver redundant power to equipment. IP Access & Security: Web interface, SSL, SSH, Telnet, SNMP or RS-232 access. Environmental Monitoring: Monitored Units support two optional external temperature & humidity probes and report conditions thru the Web interface. SNMP Traps: Automate alerts for power & environmental conditions. Multiple PDU Access: Optional software organizes and allows access of up to 1,000 Monitored PDUs from a single Web interface. Zero U and Rack-mount models: Both vertical and horizontal unit form factors are available. Unsurpassed Mounting Flexibility: Complete offering of tool-less mounting bars and side and recessed-mount brackets allow power to mount virtually anywhere in a rack. Tested to UL : Our PDUs are tested to the latest standard for IT equipment - UL Branch Circuit Protection: All Monitored PDUs with overcurrent protection utilize UL489 Listed fuses. Browser Interface Built-in web interface requires no additional software or server. Plug it in to your network and begin accessing it immediately. Branch Circuit Protection The Monitored PDU family meets the UL requirement for branch circuit protection by providing overcurrent protection with UL-listed Bussman SC fuses. Many units are equipped with the retractable fuse holder shown here for simple access. Branch Current Monitoring True RMS current monitoring is critical to preventing overloads in high-density computing environments. LED digital displays are accessible through IP-access to report the input current of each phase or branch. Environmental Monitoring Monitored PDUs support two external probes that measure both temperature and humidity. Receive SNMP-based alert notifications when conditions exceed defined thresholds. 8

9 Monitored PDU Offering Monitored Power Model Voltage Amp/kW Input Output Form Factor (LxWxD) Description PS-16-1-C20MX 120V 20A IEC C20** (16) NEMA "x1.75"x2.25" PL-16-1-C20MX 120V 20A IEC C20** (16) NEMA "x1.75"x2.25" PS-16-1-C20M 120V 20A IEC C20** (16) NEMA "x1.75"x2.25" PL-16-1-C20M 120V 20A IEC C20** (16) NEMA "x1.75"x2.25" PS-16-1-L30M 120V 30A L5-30P (16) NEMA "x1.75"x2.25" PL-16-1-L30M 120V 30A L5-30P (16) NEMA "x1.75"x2.25" PS-16-2-C20MX 208V 20A IEC C20** (16) IEC-320 C "x1.75"x2.25" PL-16-2-C20MX 208V 20A IEC C20** (16) IEC-320 C "x1.75"x2.25" Monitored PDU, (16) NEMA 5-20R Outlets, 120V 20A, C20 Inlet, No Circuit Protection Monitored PDU (Expansion Unit), (16) NEMA 5-20R Outlets, 120V, 20A input, C20 inlet, No Circuit Protection Monitored PDU, (16) NEMA 5-20R Outlets, 120V 20A, C20 Inlet Monitored PDU (Expansion Unit), (16) NEMA 5-20R Outlets, 120V, 20A input, C20 inlet Monitored PDU, (16) NEMA 5-20R Outlets, 120V, 30A, L530 input plug & cord Monitored PDU (Expansion Unit), (16) NEMA 5-20R Outlets, 120V, 30A input, L530 input plug & cord Monitored PDU, (16) C13 Outlets, 208V, 20A, C20 Inlet, No Circuit Protection Monitored PDU (Expansion Unit), (16) C13 Outlets, 208V, 20A input, C20 inlet, No Circuit Protection PS-16-2-C20M 208V 20A IEC C20** (16) IEC-320 C "x1.75"x2.25" Monitored PDU, (16) C13 Outlets, 208V, 20A, C20 Inlet PL-16-2-C20M 208V 20A IEC C20** (16) IEC-320 C "x1.75"x2.25" PS-16-2-L30M 208V 30A L6-30P (16) IEC-320 C "x1.75"x2.25" PL-16-2-L30M 208V 30A L6-30P (16) IEC-320 C "x1.75"x2.25" Monitored PDU (Expansion Unit), (16) C13 Outlets, 208V, 20A input, C20 inlet Monitored PDU, (16) C13 Outlets, 208V, 30A input, L630 plug & cord Monitored PDU (Expansion Unit), (16) C13 Outlets, 208V, 30A input, L630 plug & cord PS-24-2-C20M 208V 20A IEC C20** 69.0"x1.75"x2.25" Monitored PDU, (24) C13 Outlets, 208V, C20 Inlet PL-24-2-C20M 208V 20A IEC C20** 69.0"x1.75"x2.25" Monitored PDU (Expansion Unit), (24) C13 Outlets, 208V, C20 Inlet PS-24-2-L30M 208V 30A L6-30P 69.0"x1.75"x2.25" Monitored PDU, (24) C13 Outlets, 208V, L630P plug & cord PL-24-2-L30M 208V 30A L6-30P 69.0"x1.75"x2.25" PS-24-2-L30A 208V 30A L6-30P (18) IEC-320 C "x1.75"x2.25" PS-36-Y-L2130M 208V, 3PH 8.6kW L21-30P (36) IEC-320 C "x1.75"x3.23" PL-36-Y-L2130M 208V, 3PH 8.6kW L21-30P (36) IEC-320 C "x1.75"x 3.23" PS-36-D-L1530M 208V, 3PH 8.6kW L15-30P (36) IEC-320 C "x1.75"x3.23" PL-36-D-L1530M 208V, 3PH 8.6kW L15-30P (36) IEC-320 C "x1.75"x 3.23" PS-24-Y-L30M 208V, 3PH 8.6kW L21-30P PL-24-Y-L30M 208V, 3PH 8.6kW L21-30P (1) NEMA 5-20 (1) NEMA "x1.75"x2.25" 69.0"x1.75"x2.25" PS-24-D-L30M 208V, 3PH 8.6kW L15-30P 69.0"x1.75"x2.25" PL-24-D-L30M 208V, 3PH 8.6kW L15-30P 69.0"x1.75"x2.25" PS-30-Y-L20M 208V, 3PH 5.7kW L21-20P PL-30-Y-L20M 208V, 3PH 5.7kW L21-20P (12) NEMA 5-20 (9) IEC C13,(9) IEC C19 (12) NEMA 5-20 (9) IEC C13,(9) IEC C "x2.00"x3.23" 68.0"x2.00"x3.23" Monitored PDU (Expansion Unit), (24) C13 Outlets, 208V, L630P plug & cord Monitored PDU, (18) C13 & (6) C19 Outlets, 208V, L630 plug & cord Monitored PDU, (36) C13 Outlets, 208V - 3 Phase Wye, L2130 plug & cord Monitored PDU (expansion Unit), (36) C13 Outlets, 208V - 3 Phase Wye, L2130 plug & cord Monitored PDU, (36) C13 Outlets, 208V - 3 Phase Delta, L1530 plug & cord Monitored PDU (expansion Unit), (36) C13 Outlets, 208V - 3 Phase Delta, L1530 plug & cord Monitored PDU, (24) IEC C13 & (1) NEMA 5-20R, 208V - 3 Phase Wye, L2130 plug & cord Monitored PDU (expansion unit), (24) C13 & (1) NEMA V - 3 Phase Wye, L2130 plug & cord Monitored PDU, (24) IEC C13 Outlets, 208V - 3 Phase Delta, L1530 plug & cord Monitored PDU (expansion unit), (24) IEC C13 Outlets, 208V - 3 Phase Delta, L1530 plug & cord Monitored PDU, (12) NEMA 5-20, (9) C13 & (9) C19 120V/208V- 3PH Wye, L2120 plug & cord, Circuit Breakers Monitored PDU (expansion), (12)NEMA 5-20, (9) C13 & (9) C19 120V/208V-3 PH Wye, L2120 plug & cord, Circuit Breakers Monitored Power Distribution ** All units with an IEC C20.inlet require a power cord (ordered separately). See page 15 for input cord options. Unless noted otherwise, all Monitored units utilize fuses for over circuit protection. 9

10 Monitored PDU Offering (cont d) Monitored Power Model Voltage Amp/kW Input Output Form Factor (LxWxD) Description PS-30-Y-L30M 208V, 3PH 8.6kW L21-30P (12) NEMA 5-20 (9) IEC C13 (9) IEC C "x2.00"x3.23" Monitored PDU, (12)NEMA 5-20, (9) C13 & (9) C19 120V/208V - 3 PH Wye, L2130 plug & cord, Circuit Breakers PL-30-Y-L30M 208V, 3PH 8.6kW L21-30P (12) NEMA 5-20 (9) IEC C13 (9) IEC C "x2.00"x3.23" Monitored PDU (expansion), (12) NEMA 5-20, (9) C13, (9) C19 120V/208V-3 PH Wye, L2130 plug & cord, Circuit Breakers PS-24-Y-L20A 208V, 3PH 5.7kW L21-20P (18) IEC-320 C "x1.75"x2.25" Monitored PDU, (18) C13 & (6) C19 Outlets, 208V - 3-Phase Wye, L2120 plug & cord PS-24-Y-L30A 208V, 3PH 8.6kW L21-30P (18) IEC-320 C "x1.75"x2.25" Monitored PDU, (18) IEC C13 & Outlets, 208V - 3-Phase Wye, L2130 plug & cord PS-D48-1-C20 120V (2) 20A (2) IEC C20** (48) NEMA "x3.5"x2.25" Monitored PDU, (48) NEMA 5-20P Outlets, 120V, (2)xC20 Inlet Monitored Power Distribution PS-D48-1-L V (2) 30A (2) L5-30P (48) NEMA "x3.5"x2.25" Monitored PDU, (48) NEMA 5-20P Outlets, 120V, (2) x L530 connectors & cords PS-D48-2-C20 208V (2) 20A (2) IEC C20** (48) IEC-320 C "x3.5"x2.25" Monitored PDU, (48) C13 Outlets, 208V, (2) x C20 Inlet PS-D48-2-L V (2) 30A (2) L6-30P (48) IEC-320 C "x3.5"x2.25" PS-D48-Y-L V (2) 5.7kW (2) L21-20P (48) IEC-320 C "x3.5"x2.25" PS-D48-Y-L V (2) 8.6kW (2) L21-30P (48) IEC-320 C "x3.5"x2.25" PS-D48-D-L V (2) 5.7kW (2) L15-20P (48) IEC-320 C "x3.5"x2.25" PS-D48-D-L V (2) 8.6kW (2) L15-30P (48) IEC-320 C "x3.5"x2.25" PS-D54-Y-L V/208V (2) 8.6kW (2) L21-30P (42) IEC-320 C13 (12) NEMA "x3.5"x2.25" PS-D84-Y-L V (2) 8.6kW (2) L21-30P (84) IEC-320 C "x3.5"x2.25" PS-D84-2-L V (2) 20A (2) L6-20P (84) IEC-320 C "x3.5"x2.25" PS-D84-2-L V (2) 30A (2) L6-30P (84) IEC-320 C "x3.5"x2.25" PS-D12H-2-L V (2) 30A (2) L6-30P (12) IEC-320 C "x3.5"x10.0" PS-D12H-Y-L V (2) 8.6kW (2) L21-30P (12) IEC-320 C "x3.5"x10.0" PS-D12H-D-L V (2) 8.6kW (2) L15-30P (12) IEC-320 C "x3.5"x10.0" ** All units with an IEC C20.inlet require a power cord (ordered separately). See page 15 for input cord options. Unless noted otherwise, all Monitored units utilize fuses for over circuit protection. Monitored PDU, (48) C13 Outlets, 208V, (2) x L630 plugs & cords Monitored PDU, (48) C13 Outlets, (2) x 208V - 3 Phase 20A Wye Input, (2) x L2120 plugs & cords Monitored PDU, (48) C13 Outlets, (2) x 208V-3 Phase 30A Wye Input, (2) x L2130 plugs & cords Monitored PDU, (48) C13 Outlets, (2) x 208V-3 Phase 20A Delta Input, (2) x L1520 plugs & cords Monitored PDU, (48) C13 Outlets, (2) x 3 Phase 30A Delta Input, (2) x L1530 plugs & cords Monitored PDU, (42) C13 & (12) NEMA 5-20P Outlets, (2) x 208V-3 Phase 30A Wye, (2) x L2130 plugs & cords Monitored PDU, (84) C13 Outlets, (2) x 208V-3 Phase 30A Wye Input, (2) x L2130 plugs & cords Monitored PDU, (84) C13 Outlets, 208V, (2) x L620 plugs & cords Monitored PDU, (84) C13 Outlets, 208V, (2) x L630 plugs & cords Monitored PDU, 19" R/M - 2U, (12) x C19 Outlets, 208V, 30A, (2) x L630 plugs & cords Monitored PDU, 19" R/M - 2U, (12) x C19 Outlets, 208V-3 Phase Wye - 30A, (2) x L2130 plugs & cords Monitored PDU, 19" R/M - 2U, (12) x C19 Outlets, 208V-3 Phase Delta - 30A, (2) x L1530 plug & cords Technical Specifications Standards > CTUVus UL > CAN/CSA 22.2 No :2003 > TUV_GS EN :2001 > FCC Class A Part 15 > CE > EMC-EN Class A, EN Communications > 10/100 BaseT Ethernet > SSLv3/TLSv1 > SNMPv2 > HTTP/HTTPS > SSHv2 > Telnet > TACACS+ 10

11 Switched PDUs Turn receptacles on or off from anywhere via remote IP access Switched power distribution by Electrorack delivers complete control of power within the equipment rack. Individual on/off control of receptacles, power on sequencing, smart load shedding, outlet grouping over multiple circuits (whips), environmental monitoring and user defined alerts give IT administrators complete control of power within the equipment rack. Local digital displays of aggregate current load give installers accurate readings of equipment current draw. IP access to PDUs allows network operators to monitor power usage and accurately forecast future power needs. Remote monitoring features include 10/100 BaseT Ethernet interface for SSL Web, SSH, Telnet, & SNMP control and console port access to remote servers, routers and network equipment. Switched PDU Features & Benefits Remotely Reboot Equipment: Cycle individual power outlets, or groups of outlets to remotely reboot servers or devices, anywhere in the world. Receptacle Control: Turn off unused outlets to avoid circuit over loads. Input Current Monitoring: Precisely measure the aggregate current draw (in amps) on each power circuit utilizing a true RMS meter to avoid overloading circuits. On-site verification of the input current with the LED digital display. Remote verification via browser or serial screen. Multiple Power Distribution Options: 120V, 208V & 3-phase power options. Available in 20 & 30-Amp power input feeds to maximize whip efficiency to your load. Expansion Modules: Link Master & Expansion units for management of separate circuits from a single IP address Power-up Sequencing: User defined power on intervals prevent in-rush power overloads. Single or Dual Circuit Options: Single or Dual input feeds with varying receptacle styles and densities. Dual feed units cost-effectively deliver redundant power to equipment. IP Access & Security: Web interface, SSL, SSH, Telnet, SNMP or RS-232 access. Environmental Monitoring: Switched Units support two optional external temperature & humidity probes and reports conditions thru the Web interface. SNMP Traps: Automate alerts for undesirable conditions. Multiple PDU Access: Optional software organizes and allows access of up to 1,000 Monitored PDUs from a single Web interface. Zero U and Rack-mount models: Both vertical and horizontal unit form factors are available. Unsurpassed Mounting Flexibility: Complete offering of tool-less mounting bars, side-mount and recessed brackets allow power to mount virtually anywhere in a rack. Tested to UL : Our PDU offering is tested to the latest standard for IT equipment - UL Branch Circuit Protection: All Monitored PDUs with overcurrent protection utilize UL489 Listed fuses. 11 Browser Interface Built-in web interface requires no additional software or server. Plug it in to your network and begin accessing it immediately. Expansion Units The Switched PDU family offers expansion units that link to master units and enable access to two separate PDUs via a single IP address. Receptacles can be grouped across circuits which ideal for controlling dual power supply equipment. Branch Circuit Protection The Switched PDU family meets the UL requirement for branch circuit protection by providing overcurrent protection with UL-listed Bussman SC fuses. Many units are equipped with the retractable fuse holder shown here for simple access. Branch Current Monitoring True RMS current monitoring is critical to preventing overloads in high-density computing environments. LED digital displays are accessible through IP-access to report the input current of each phase or branch. Environmental Monitoring Switched PDUs support two external probes that measure both temperature and humidity. Receive SNMP-based alert notifications when conditions exceed defined thresholds. Switched Power Distribution

12 Switched PDU Offering Switched Power - Vertical Power Model Voltage Amp/kW Input Output Form Factor (LxWxD) Description PC-16-1-C20MX 120V 20A IEC C20** (16) NEMA "x1.75"x2.25" PX-16-1-C20MX 120V 20A IEC C20** (16) NEMA "x1.75"x2.25" PC-16-2-C20MX 208V 20A IEC C20** (16) IEC-320 C "x1.75"x2.25" PX-16-2-C20MX 208V 20A IEC C20** (16) IEC-320 C "x1.75"x2.25" PC-16-1-L30M 120V 30A L5-30P (16) NEMA "X1.75"x2.25" Switched PDU, (16) NEMA 5-20R Outlets, 120V, 20A, C20 Inlet, No Circuit Protection Switched PDU (Expansion), (16) NEMA 5-20R Outlets, 120V, 20A, C20 inlet, No Circuit Protection Switched PDU, (16) C13 Outlets, 208V, 20A, C20 Inlet, No Circuit Protection Switched PDU (Expansion), (16) C13 Outlets, 208V, 20A, C20 inlet, No Circuit Protection Switched PDU, (16) NEMA 5-20R Outlets, 120V, 30A, L530 plug & cord Switched Power Distribution PX-16-1-L30M 120V 30A L5-30P (16) NEMA "X1.75"x2.25" Switched PDU (Expansion), (16) NEMA 5-20R Outlets, 120V, 30A, L530 plug & cord PC-16-2-L30M 208V 30A L6-30P (16) IEC-320 C "X1.75"x2.25" Switched PDU, (16) C13 Outlets, 208V, 30A, L630 plug & cord PX-16-2-L30M 208V 30A L6-30P (16) IEC-320 C "X1.75"x2.25" Switched PDU (Expansion), (16) C13 Outlets, 208V, 30A, L630 plug & cord PC-24-2-C20M 208V 20A IEC C20** 69.0"x1.75"x2.25" Switched PDU, (24) C13 Outlets, 208V, 20A, C20 Inlet PX-24-2-C20M 208V 20A IEC C20** 69.0"x1.75"x2.25" Switched PDU (Expansion), (24) C13 Outlets, 208V, 20A, C20 Inlet PC-24-2-L30M 208V 30A L6-30P 69.0"x1.75"x2.25" Switched PDU, (24) C13 Outlets, 208V 30A, L630 plug & cord PX-24-2-L30M 208V 30A L6-30P 69.0"x1.75"x2.25" PC-24-Y-L20M 208V 3PH 5.7kW L21-20P 69.0"x1.75"x2.25" PX-24-Y-L20M 208V 3PH 5.7kW L21-20P 69.0"x1.75"x2.25" PC-24-Y-L30M 208V 3PH 8.6kW L21-30P 69.0"x1.75"x2.25" PX-24-Y-L30M 208V 3PH 8.6kW L21-30P 69.0"x1.75"x2.25" PC-D32-1-C20 120V (2) 20A (2) IEC C20** (32) NEMA "x3.5"x2.25" PX-D32-1-C20 120V (2) 20A (2) IEC C20** (32) NEMA "x3.5"x2.25" PC-D32-1-L V (2) 30A (2) L5-30P (32) NEMA "x3.5"x2.25" Switched PDU (Expansion), (24) C13 Outlets, 208V, 30A, L630 plug & cord Switched PDU, (24) C13 Outlets, 208V - 3 Phase Wye, 20A, L2120 plug & cord Switched PDU (Expansion), (24) C13 Outlets, 208V - 3 Phase Wye, 20A, L2120 plug & cord Switched PDU, (24) C13 Outlets, 208V - 3 Phase Wye, 30A, L2130 plug & cord Switched PDU (Expansion), (24) C13 Outlets, 208V - 3 Phase Wye, 30A, L2130 plugs & cord Switched Dual Circuit PDU, (32) NEMA 5-20R Outlets, 120V, 20A, (2) C20 Inlets Switched Dual Circuit PDU (Expansion), (32) NEMA 5-20R Outlets, 120V, 20A, (2) C20 inlets Switched Dual Circuit PDU, (32) NEMA 5-20R Outlets, 120V, 30A, (2) L530 plugs & cords PX-D32-1-L V (2) 30A (2) L5-30P (32) NEMA "x3.5"x2.25" PC-D32-2-C20 208V (2) 20A (2) IEC C20** (32) IEC-320 C "x3.5"x2.25" PX-D32-2-C20 208V (2) 20A (2) IEC C20** (32) IEC-320 C "x3.5"x2.25" PC-D32-2-L V (2) 30A (2) L6-30P (32) IEC-320 C "x3.5"x2.25" PX-D32-2-L V (2) 30A (2) L6-30P (32) IEC-320 C "x3.5"x2.25" Switched Dual Circuit PDU (Expansion), (32) NEMA 5-20R Outlets, 120V, 30A, (2) L530 plugs & cords Switched Dual Circuit PDU, (32) C13 Outlets, 208V, 20A, (2) C20 Inlets Switched Dual Circuit PDU (Expansion), (32) C13 Outlets, 208V, 20A, (2) C20 Inlets Switched Dual Circuit PDU, (32) C13 Outlets, 208V, 30A, (2) L630 plugs & cords Switched Dual Circuit PDU (Expansion), (32) C13 Outlets, 208V, 30A, (2) L630 plugs & cords ** All units with an IEC C20.inlet require a power cord (ordered separately). See page 15 for input cord options. 12

13 Switched PDU Offering (cont d) Switched Power - Horizontal Units Model Voltage Amp/kW Input Output Form Factor (LxWxD) Description PC-8H-1-C20 120V 20A IEC C20** (8) NEMA "x1.75"x7.0" PX-8H-1-C20 120V 20A IEC C20** (8) NEMA "x1.75"x7.0" PC-8H-1-L V 30A L5-30P (8) NEMA "x1.75"x7.0" PX-8H-1-L V 30A L5-30P (8) NEMA "x1.75"x7.0" Switched PDU, (8) NEMA 5-20R outlets, 120V, 20A input, C20 inlet Switched PDU (Expansion), (8) NEMA 5-20R outlets, 120V, 20A input, C20 inlet Switched PDU, (8) x NEMA 5-20R outlets, 120V, 30A, L530 plugs & cord Switched PDU (Expansion Unit), (8) x NEMA 5-20R outlets, 120V 30A input, L530 plug & cord PC-8H-2-C20 208V 20A IEC C20** (8) IEC-320 C "x1.75"x7.0" Switched PDU, (8) C13 outlets, 208V 20A input, C20 inlet PX-8H-2-C20 208V 20A IEC C20** (8) IEC-320 C "x1.75"x7.0" PC-8H-2-L V 30A L6-30P (8) IEC-320 C "x1.75"x7.0" PX-8H-2-L V 30A L6-30P (8) IEC-320 C "x1.75"x7.0" ** All units with an IEC C20.inlet require a power cord (ordered separately). See page 15 for input cord options. Technical Specifications Standards > CTUVus UL > CAN/CSA 22.2 No :2003 > TUV_GS EN :2001 > FCC Class A Part 15 > CE > EMC-EN Class A, EN Communications > 10/100 BaseT Ethernet > SSLv3/TLSv1 > SNMPv2 > HTTP/HTTPS > SSHv2 > Telnet > TACACS+ Switched PDU (Expansion Unit), (8) C13 outlets, 208V 20A input, C20 inlet Switched PDU, (8) C13 outlets, 208V 30A input, L630 plug & cord Switched PDU (Expansion Unit), (8) C13 outlets, 208V 30A input, L630 plug & cord Switched Power Distribution 13

14 Power Mounting Vertical Power Mounting Bars Fits Frame Height 2.4 Wide Part Number 4.6 Wide Part Number 6.8 Wide Part Number Power Mounting Accessories 20U PMV PMV PMV U PMV PMV PMV U PMV PMV PMV U PMV PMV PMV U PMV PMV PMV U PMV PMV PMV U PMV PMV PMV U PMV PMV PMV U PMV PMV PMV U PMV PMV PMV U PMV PMV PMV U PMV PMV PMV Allows mounting of tool-less button-mounted power Bar Mounts to front to back unistrut frame members (3 or 4 strut frames) Includes slots on either side for cable lacing Material: 16 GA (0.060 ) steel Cable Rings - Power Bar Mount Dimensions: 2.4,4.6, or 6.8 Wide x 0.38 Deep x Height (table) Use 2.4 W for one unit, 4.6 W for two units & 6.8 W for three units or 2 units with cable rings Keyslot spacing: vertically & 2.2 wide on center Includes hardware (3 UniStrut Nuts & (3) 1/4-20 bolts) to mount to front-to-back frame members Color: Black Use with 6.8 or 4.6 Wide Vertical Power Bars 1.75 Wide x 4.00 Deep (outside dimensions) Includes #10-32 screws and clip nuts (1 set per ring) Ship individually or packs of 10 Color: Black Part Number Description CRP x 4 Screw Mount Cable Rings, Qty. 1 CRP x 4 Screw Mount Cable Rings,Qty. 10 Mounting Buttons PM-VB2-2 includes 2 buttons and 2 #6-32 counter sunk screws Color: Black Part Number Description PM-VB2-2 Power Mounting Buttons, Qty. 2 14

15 Power Mounting & Cords Side-mount Brackets with Buttons Side-mount kits include 2 steel brackets, 2 buttons & 2 #6-32 screws Side-mount Kit allows orientation of receptacles toward front or rear of the rack when mounted on power bars Select kit based on strip width W or 2.2 W Color: Black Part Number PM-VS1-2 PM-VS2-2 Description Side-mount Bracket Kit for 1.72 W Strips Side-mount Bracket Kit for 2.2 W Strips Recessed Rack-mount Bracket Kit w/cable Retention Bracket Power Cords & Sensors Recessed kits include 2 steel brackets, 1 cable retention bar for strain relief and 4 each #10-32 screws and clip nuts - order velcro separately Recessed Kit allows ample clearance for plugs while retention bar helps keep cords in same rack unit Color: Black Power Input Cords - Source to C20 Inlet NEMA 5-15P NEMA 5-20P NEMA L5-20P NEMA L6-20P Power Equipment Cords - IEC Equipment to PDU Shorter Equipment power cables reduce excess cable bundles inside the rack, improving access and airflow by minimizing blockages Part Number PCS-01 PCS-02 PCS-03 PCS-04 Part Number PCE-18 PCE-36 PCE-72 Part Number Description PM-HMR-2 Recessed Bracket Kit for 19 Rack-mounting VT-10 Velcro - 8 Straps, set of 10 Description Input Cord for C20 Inlet- IEC C19 to NEMA 5-15P, 120V, 10 Length Input Cord for C20 Inlet- IEC C19 to NEMA 5-20P, 120V, 10 Length Input Cord for C20 Inlet- IEC C19 to NEMA L5-20P, 120V, 10 Length Input Cord for C20 Inlet- IEC C19 to NEMA L6-20P, 208V, 10 Length Description Input Cord for C20 Inlet- IEC C19 to NEMA 5-15P, 120V, 10 Length Input Cord for C20 Inlet- IEC C19 to NEMA 5-20P, 120V, 10 Length Input Cord for C20 Inlet- IEC C19 to NEMA L5-20P, 120V, 10 Length Power Mounting Accessories & Cords Environmental Monitoring Sensor Sensors measure temperature and humidity and can be used with Monitored or Switched PDUs Part Number Description E-THM-1 Temperature/Humidity Probe, 10 Length 15

16 ENCLOSURE SOLUTIONS FOR BROADCAST & BROADBAND DATACENTER/IT & NETWORKING MILITARY/ENVIRONMENTAL OEM/CUSTOM Electrorack is an ISO 9001 and AS9100 certified electronic enclosure manufacturer located in Anaheim, California. Utilizing over 50 years of experience in designing electronic enclosures to exacting performance requirements, Electrorack has developed many innovative, pre-engineered solutions for industry standard needs. At Electrorack we pride ourselves on being an engineering-based manufacturer. Our design capabilities include: parametric 3D modeling, in-house parallel design support, and web-based design reviews. Consistent growth is a testament to our process of listening to our customer s needs and designing solutions for their problems. We offer diverse solutions for the Broadcast and Broadband, Datacom, Industrial/Electronic, Military and OEM markets. Our knowledgeable in-house staff of design engineers and sales associates are available to answer technical questions for any application or environment. Give us a call! DEFINE. DESIGN. DELIVER. All Products and Company names are trademarks or registered trademarks of their respective holders. Every effort has been made to ensure the information contained herein is correct. Electrorack reserves the right to modify product specifications without notice and assumes no responsibility for any errors which may appear in this publication South Sunkist Street Anaheim, CA T F E info@electrorack.com Copyright Electrorack Enclosure Products, 2008 Form B/0k/ Printed in the USA

Racks & Enclosures. Deliver. Design. Define. Three simple words that clearly describe how we approach a Data Center project.

Racks & Enclosures. Deliver. Design. Define. Three simple words that clearly describe how we approach a Data Center project. Three simple words that clearly describe how we approach a Data Center project. Eclipse Racks & Enclosures DELIVERING THE RIGHT INFRASTRUCTURE FOR YOUR MISSION-CRITICAL NEEDS SERVER RACKS & NETWORKING

More information

How To Power A Bladecenter H Servers

How To Power A Bladecenter H Servers Solutions Guide for IBM Data Center Architecture: IBM BladeCenter H Servers In today s high-demand enterprise environment, organizations need a reliable infrastructure to run compute-intensive applications

More information

Rack Systems Solutions

Rack Systems Solutions Rack Systems Solutions Designed to simplify cable management and improve power distribution Engineered by APC by Schneider Electric for Dell, NetShelter S is the next-generation rack enclosure solution

More information

Power Commander Power Distribution Units from Wiremold/Legrand offer

Power Commander Power Distribution Units from Wiremold/Legrand offer Power Commander Power Distribution Units Rack Power Distribution Solutions for IT/Network Environments Power Commander Power Distribution Units from Wiremold/Legrand offer comprehensive power distribution

More information

QuickSpecs. HP Managed Power Distribution Units (mapdu) Overview

QuickSpecs. HP Managed Power Distribution Units (mapdu) Overview Overview Looking for a power distribution unit that meets the demands of high temperature operating environments and provides monitoring and switching capabilities? The HP Managed Power Distribution Unit

More information

8 Intelligent PDUs. Intelligent Power Distribution Units for Data Centers

8 Intelligent PDUs. Intelligent Power Distribution Units for Data Centers BRC_PDU_US_B_BRC_IcePack 4/30/13 11:31 AM Page 2 8 Intelligent PDUs Intelligent Power Distribution Units for Data Centers Intelligent Power Distribution Units Siemon s line of intelligent PDUs provide

More information

ED1259R5 Updated April 2011 For latest specs visit www.legrand.us/wiremold

ED1259R5 Updated April 2011 For latest specs visit www.legrand.us/wiremold Rack Power Distribution Solutions for IT/Network Environments Wiremold Power Commander Power Distribution Units offer comprehensive power distribution solutions for IT environments from networking solutions

More information

Panduit Infrastructure Management Software for Data Centers and Enterprises

Panduit Infrastructure Management Software for Data Centers and Enterprises Panduit Infrastructure Management Software for Data Centers and Enterprises SmartZone Rack Energy Kits Energy and Environmental Monitoring for Small Data Centers SmartZone Rack Energy Kits Features: Simple

More information

Eaton epdu. Intelligent and flexible power distribution

Eaton epdu. Intelligent and flexible power distribution Eaton epdu Intelligent and flexible power distribution Introduction and overview With today s changing technology, increasing power demands and the need for reliability, data centre professionals require

More information

Rack Power Distribution

Rack Power Distribution The Rack PDU Selector is located at: www.apc.com/tools/selector/pdu Test drive a metered or switched Rack Power Distribution Rack PDU at testdrive.apc.com 132 Fairgrounds Road West Kingston, RI 02892 Phone:

More information

CenterMind P+ Solution for efficient power management

CenterMind P+ Solution for efficient power management CenterMind P+ Solution for efficient power management Overview Over last decade DC become significant power consuming facilities Information Technology Equipment (ITE) continue to increase computing capabilities

More information

Rack Power Distribution. Worldwide

Rack Power Distribution. Worldwide Rack Distribution Worldwide Introduction APC TM by Schneider Electric TM offers a wide array of standardized Rack Distribution Units (PDUs) designed to increase manageability and efficiency in your data

More information

QuickSpecs. HP Remote Monitored Power Distribution Units (mpdu) Overview

QuickSpecs. HP Remote Monitored Power Distribution Units (mpdu) Overview Overview HP Remote Monitored Power Distribution Units (PDU) provide rack level power monitoring over the network. With billing grade accuracy these PDUs are excellent choices for data centers wanting to

More information

Table of Contents. 1. Introduction...1. 2. PDU Package...2. 3. Function...3. 4. Installation...5. 5. Web Interface...7

Table of Contents. 1. Introduction...1. 2. PDU Package...2. 3. Function...3. 4. Installation...5. 5. Web Interface...7 PDU User Manual Table of Contents 1. Introduction...1 2. PDU Package...2 3. Function...3 4. Installation...5 5. Web Interface...7 1. Introduction The PDU is an Internet ready device designed and is equipped

More information

Energy Management Solutions

Energy Management Solutions Energy Management Solutions Introducing the world s most innovative intelligent Power Distribution Units (ipdus) designed to simplify rack energy and environmental management of your data center. Enlogic

More information

PE8216/PE8324. Energy Intelligence Solutions

PE8216/PE8324. Energy Intelligence Solutions PE8216/PE8324 As part of its NRGence line, ATEN has developed a new generation of green energy power distribution units (eco PDUs) to effectively increase the efficiency of data center power usage. The

More information

Power Distribution Considerations for Data Center Racks

Power Distribution Considerations for Data Center Racks Power Distribution Considerations for Data Center Racks Power Distribution Considerations for Data Center Racks Table of Contents 3 Overview 4 At what voltage do you run all the IT equipment? 4 What electrical

More information

PE6108/PE6208/PE8108/PE8208

PE6108/PE6208/PE8108/PE8208 Energy Intelligence Solutions PE6108/PE6208/PE8108/PE8208 eco PDU Distribution Unit ATEN has developed a new generation of green energy power distribution units (PDUs) to effectively increase the efficiency

More information

Distributing Power to Blade Servers

Distributing Power to Blade Servers Distributing Power to Blade Servers Ten steps to selecting the optimal power distribution design With the growth in blade servers with dual or triple power supplies, a single rack of equipment can easily

More information

CS-24HEK4B3H2 (Master) CL-24HEK4B3H2 (Expansion) Key Features. Inputs

CS-24HEK4B3H2 (Master) CL-24HEK4B3H2 (Expansion) Key Features. Inputs CS-24HEK4B3H2 (Master) CL-24HEK4B3H2 (Expansion) The Server Technology Smart PDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis

More information

How do I... POPS Smart & Switched CDU. If you manage a datacenter, we have a solution for you.

How do I... POPS Smart & Switched CDU. If you manage a datacenter, we have a solution for you. POPS Smart & Switched CDU Zero-U & Rack Mounted CDUs with Per Outlet Power Sensing If you manage a datacenter, we have a solution for you. How do I... Monitor current, voltage, power (kw), apparent power,

More information

Cabinets 101: Configuring A Network Or Server Cabinet

Cabinets 101: Configuring A Network Or Server Cabinet Cabinets 101: Configuring A Network Or Server Cabinet North, South and Central America White Paper May 2012 www.commscope.com Contents Background Information 3 What is a network or server cabinet? 3 What

More information

Intelligent Power Distribution

Intelligent Power Distribution Eaton epdu Intelligent Power Distribution Maximise and manage your rack power Eaton epdus Managed epdus Advanced Monitored epdus Managed epdus offer data centre managers maximum functionality and flexibility,

More information

Remote Site Management Solutions

Remote Site Management Solutions Remote Site Management Solutions Bay Technical Associates 200 N. 2 nd Street Bay St. Louis, MS 39520 800-523-2702 * Fax 228-467-4551 International 228-467-8231 1.0 REMOTE SITE MANAGEMENT (SELLING THE CONCEPT

More information

PN5212/PN5320/PN7212/PN7320

PN5212/PN5320/PN7212/PN7320 PN522/PN5/PN722/PN7 Over the NET Distribution Units ALTUSEN Over the NET products are Distribution Units that offer outlet level control combined with remote access to give IT administrators the ability

More information

DCF Optimized Rack System Selection Guide

DCF Optimized Rack System Selection Guide DCF Optimized Rack System Selection Guide DCF Optimized Rack System: Optimized Design, Optimized Delivery, Optimized Value A Rack System Designed to Meet The Challenges Your Data Center Faces Today Your

More information

Emerson Network Power Rack PDU Systems

Emerson Network Power Rack PDU Systems AC Power For Business-Critical Continuity Emerson Network Power Rack PDU Systems Product Selection Guide - North American Models TABLE OF CONTENTS 1.0 EMERSON NETWORK POWER RACK PDU SYSTEMS..............................1

More information

QuickSpecs. Overview. HP Power Distribution Rack. HP Power Distribution Rack. DA - 12859 North America Version 5 August 22, 2008 Page 1

QuickSpecs. Overview. HP Power Distribution Rack. HP Power Distribution Rack. DA - 12859 North America Version 5 August 22, 2008 Page 1 Overview It's getting harder to manage a data center efficiently, with rising utility bills and ever-increasing demands due to processor power and server density increases. Growing user requests mean heavier

More information

Precisely distribute, monitor, analyze and manage power distribution in your facility to maximize processing capacity and promote power efficiency.

Precisely distribute, monitor, analyze and manage power distribution in your facility to maximize processing capacity and promote power efficiency. SECTION FOUR Table of Contents Page 69-78 Enclosure Power Distribution Units (PDUs) 70 71 Single-Phase Basic/Smart PDUs 72 3-Phase Basic/Smart PDUs 73 Single- and 3-Phase Switched PDUs 74 PDU Accessories

More information

DATA CENTER SOLUTIONS

DATA CENTER SOLUTIONS DATA CENTER SOLUTIONS Nobody Makes Better Data Center Equipment Maximize availability, manageability and efficiency with cost-effective solutions from a dependable partner. Provide reliable, efficient

More information

Optimizing Rack Power Distribution

Optimizing Rack Power Distribution Optimizing Rack Power Distribution Best practices for selecting the right rack power distribution unit for your environment By Joe Skorjanec Product Manager Eaton Executive summary With information increasingly

More information

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments Model #: SM2000RMX Heavy-duty, industrial-grade metal housings Shock and vibration rated to MIL-STD-810D 19 inch

More information

Spec Sheet. Cisco R42610 Rack CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV A.6 DECEMBER 9, 2014 WWW.CISCO.

Spec Sheet. Cisco R42610 Rack CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV A.6 DECEMBER 9, 2014 WWW.CISCO. Spec Sheet CISCO SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR. SAN JOSE, CA, 95134 REV A.6 DECEMBER 9, 2014 WWW.CISCO.COM Overview................................................ 3 Rack Certifications

More information

Acano solution. Acano Solution Installation Guide. Acano. January 2014 76-1002-03-B

Acano solution. Acano Solution Installation Guide. Acano. January 2014 76-1002-03-B Acano solution Acano Solution Installation Guide Acano January 2014 76-1002-03-B Contents Contents 1 Introduction... 3 1.1 Before You Start... 3 1.1.1 Safety information... 3 1.1.2 You will need the following

More information

3U, 2200 VA Audio/Video Pure Sine Wave UPS System

3U, 2200 VA Audio/Video Pure Sine Wave UPS System 3U, 2200 VA Audio/Video Pure Sine Wave UPS System MODEL NUMBER: HTR22-3U Description Tripp Lite's HTR22-3U Pure Sine Wave 2200VA/1600W on-line, double-conversion UPS system prevents media data loss, equipment

More information

QuickSpecs. HP Fixed Cord PDUs & Extension Bars (Zero-U/1U Modular PDUs) Overview

QuickSpecs. HP Fixed Cord PDUs & Extension Bars (Zero-U/1U Modular PDUs) Overview Overview Fixed Cord PDUs and Extension Bars have a unique architecture designed specifically for 1U fixed rail servers (HP ProLiant DL360, HP ProLiant DL320, HP ProLiant DL140). This new design consists

More information

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications Model #: SU3000RTXL3U 3000VA online 3U rack / tower UPS Enhanced serial communications

More information

Intelligent Power Distribution in the Data Center

Intelligent Power Distribution in the Data Center Rack Power Intelligent Power Distribution in the Data Center Agenda Data Centre Power UPS Power Distribution Rack Mount PDU s UPS Power problems Configuration Capacity Power Distribution Types of Distribution

More information

How to Maximize Data Center Efficiencies with Rack Level Power Distribution and Monitoring

How to Maximize Data Center Efficiencies with Rack Level Power Distribution and Monitoring How to Maximize Data Center Efficiencies with Rack Level Power Distribution and Monitoring Brian Rehnke e-pdu Business Development Manager November, 2011 The Problems Energy Usage in most data centers

More information

Secure your IT equipment with confidence... secure with NetClosure

Secure your IT equipment with confidence... secure with NetClosure Secure your IT equipment with confidence... secure with NetClosure SERVER CABINETS NetClosure s REM Series Server Cabinet is the ultimate solution designed and engineered for demanding data center environments.

More information

RELIABLE AND FLEXIBLE POWER FOR YOUR DATA CENTRE

RELIABLE AND FLEXIBLE POWER FOR YOUR DATA CENTRE RELIABLE AND FLEXIBLE POWER FOR YOUR DATA CENTRE Highly efficient solutions for power distribution, management and monitoring POWER DISTRIBUTION WIRE-FREE MONITORING LEAK DETECTION Daxten provides comprehensive

More information

Intelligent Power Distribution

Intelligent Power Distribution Eaton epdu Intelligent Power Distribution Maximise and manage your rack power Maximise and manage your rack power Two key trends have emerged in the data centre: the demand from today s IT equipment for

More information

HP UPS R1500 Generation 3

HP UPS R1500 Generation 3 HP UPS R1500 Generation 3 Installation Instructions Part Number 650952-001 NOTE: The rating label on the device provides the class (A or B) of the equipment. Class B devices have a Federal Communications

More information

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V SmartPro VS Tower UPS System Intelligent, line-interactive power management system Model #: SMART2200VS 2200VA / 2.2kVA line interactive tower UPS Maintains 120V nominal output over an input range of 79

More information

ZONIT POWER DISTRIBUTION SYSTEM ORDER CATALOG

ZONIT POWER DISTRIBUTION SYSTEM ORDER CATALOG ZONIT POWER DISTRIBUTION SYSTEM ORDER CATALOG Introduction The Zonit Data Center Power Distribution System (zpds ) offers an ultrareliable, turnkey power distribution system for modern high-availability

More information

Eaton epdu Data Center Product Catalog

Eaton epdu Data Center Product Catalog Power distribution solutions Eaton epdu Data Center Product Catalog Switch N to Eaton. 2 eaton corporation Enclosure Power Distribution Units Table of contents Product Line Overview... 4 Choosing epdu

More information

Smart-UPS On-Line 230 V

Smart-UPS On-Line 230 V Smart-UPS On-Line 230 V Unity output power factor single-phase, double-conversion online UPS with advanced management features A versatile UPS developed for unstable power conditions worldwide Smart-UPS

More information

QuickSpecs. HP Modular Power Distribution Units (Zero-U/1U Modular PDUs) Overview

QuickSpecs. HP Modular Power Distribution Units (Zero-U/1U Modular PDUs) Overview Overview HP Modular PDUs have a unique modular architecture designed specifically for data center customers who want to maximize power distribution and space efficiencies in the rack. Modular PDUs consist

More information

QuickSpecs. HP 480/277 Volt Solutions. Overview

QuickSpecs. HP 480/277 Volt Solutions. Overview Overview As the quest for efficiency continues it becomes apparent that what worked in the past needs improvement. More and more data center managers are looking at alternate power plans to distribute

More information

EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS EMC Data Domain deduplication storage systems continue to revolutionize disk backup, archiving, and disaster recovery with high-speed, inline deduplication.

More information

Job Aid Pre-Installation Information S8500 Media Server

Job Aid Pre-Installation Information S8500 Media Server Required information Job Aid Pre-Installation Information S8500 Media Server This job aid provides the information, hardware requirements, and computer hardware and software specifications necessary for

More information

QuickSpecs. HP R/T3000 G2 Uninterruptible Power System (UPS) Overview

QuickSpecs. HP R/T3000 G2 Uninterruptible Power System (UPS) Overview Overview The industry leading packs up to 3000 watts into a space saving 2U design. Proven Digital Signal Processor (DSP) double conversion system provides clean, reliable power protection in an energy

More information

A Smart Investment for Flexible, Modular and Scalable Blade Architecture Designed for High-Performance Computing.

A Smart Investment for Flexible, Modular and Scalable Blade Architecture Designed for High-Performance Computing. Appro HyperBlade A Smart Investment for Flexible, Modular and Scalable Blade Architecture Designed for High-Performance Computing. Appro HyperBlade clusters are flexible, modular scalable offering a high-density

More information

HP R/T3000 G2 Uninterruptible Power System (UPS) Overview

HP R/T3000 G2 Uninterruptible Power System (UPS) Overview Overview The industry leading packs up to 3000 watts into a space saving 2U design. Proven Digital Signal Processor (DSP) double conversion system provides clean, reliable power protection in an energy

More information

AC Power For Business-Critical Continuity. Liebert MPH. User Manual North American & European Applications

AC Power For Business-Critical Continuity. Liebert MPH. User Manual North American & European Applications AC Power For Business-Critical Continuity Liebert MPH User Manual North American & European Applications TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS................................................1

More information

Model #: SMART2200CRMXL

Model #: SMART2200CRMXL Tripp Lite 1111 West 35th Street Chicago, IL 60609 USA Telephone: +(773) 869 1234 E-mail: saleshelp@tripplite.com Model #: SMART2200CRMXL SmartPro Compact Rackmount UPS System - Precision Protection for

More information

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial MODEL NUMBER: SMART1000RM1U Description Tripp Lite SMART1000RM1U 1000VA / 1kVA / 800 watt line interactive,

More information

How to Set Up Your NSM4000 Appliance

How to Set Up Your NSM4000 Appliance How to Set Up Your NSM4000 Appliance Juniper Networks NSM4000 is an appliance version of Network and Security Manager (NSM), a software application that centralizes control and management of your Juniper

More information

CenterMind P+ Intelligent Power Management for your Data Center

CenterMind P+ Intelligent Power Management for your Data Center CenterMind P+ Intelligent Power Management for your Data Center Intelligent Power Management for your Data Center monitor and manage your data center power consumption and connectivity efficiently The

More information

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial MODEL NUMBER: SMART750RM1U Highlights.75kVA / 750VA / 600W line interactive 1U rackmount UPS,

More information

Power Distribution Systems for the Dell PowerEdge M1000e Modular Server Enclosure - Selection and Installation

Power Distribution Systems for the Dell PowerEdge M1000e Modular Server Enclosure - Selection and Installation One Dell Way Round Rock, Texas 78682 www.dell.com Dell Enterprise White Paper Power Distribution Systems for the Dell PowerEdge M1000e Modular Server Enclosure - Selection and Installation January, 2008

More information

Uninterruptible Power Supply

Uninterruptible Power Supply 96-01101 / rev. 2e / 2-2-12 Uninterruptible Power Supply EXCEPTIONAL SUPPORT & PROTECTION Uninterruptible Power Supply with Energy Saver design that is optimized to address the needs of A/V systems Features

More information

Advantages of Wire- Free Power Monitoring in the Data Center

Advantages of Wire- Free Power Monitoring in the Data Center Advantages of Wire- Free Power Monitoring in the Data Center Using PIPS (Per Inlet Power Sensing) and POPS (Per Outlet Power Sensing) CDU Technology with RF Code s Wire- Free Solutions February 3, 2011

More information

R5000 Uninterruptible Power System (UPS) Overview

R5000 Uninterruptible Power System (UPS) Overview Overview The innovative Minimally Switched Technology used in the HP R5000 UPS improves the performance over traditional line-interactive UPS designs while reducing the cost, weight, and size of traditional

More information

TrueAlarm Fire Alarm Systems

TrueAlarm Fire Alarm Systems TrueAlarm Fire Alarm Systems UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Fire Alarm System Accessories, 4190 Series PC Annunciator with Multi-Client Capability Features Fire alarm control

More information

R5000 Uninterruptible Power System (UPS) Overview

R5000 Uninterruptible Power System (UPS) Overview Overview The innovative Minimally Switched Technology used in the HP R5000 UPS improves the performance over traditional lineinteractive UPS designs while reducing the cost, weight, and size of traditional

More information

Chassis, Power Supply, and Element Management

Chassis, Power Supply, and Element Management Chassis, Power Supply, and Element Management C-COR CHP Max5000 Converged Headend Platform Accelerate deployment of new, revenue generating advanced services Innovative technology creating converged high-

More information

Data Center Rack Systems Key to Business-Critical Continuity. A White Paper from the Experts in Business-Critical Continuity TM

Data Center Rack Systems Key to Business-Critical Continuity. A White Paper from the Experts in Business-Critical Continuity TM Data Center Rack Systems Key to Business-Critical Continuity A White Paper from the Experts in Business-Critical Continuity TM Executive Summary At one time, data center rack enclosures and related equipment

More information

Buyer s Guide to Dell Power Distribution Units

Buyer s Guide to Dell Power Distribution Units Buyer s Guide to Dell Power Distribution Units With data center devices smaller than ever, often served by dual- or triple-power supplies, a single rack of equipment might produce 80 or more power cords

More information

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial MODEL NUMBER: SMART750RM1U Highlights.75kVA / 750VA / 600W line interactive 1U rackmount UPS, Sine

More information

AIS 3000 APC AIS 3000 15kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

AIS 3000 APC AIS 3000 15kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass AIS 3000 APC AIS 3000 15kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass APC AIS 3000, 12 kw / 15 kva,input 208V 3PH / Output 120V, 208V, 208V 3PH, Interface Port DB-9 RS-232,

More information

ADC-APC Integrated Cisco Data Center Solutions

ADC-APC Integrated Cisco Data Center Solutions Advanced Infrastructure Solution for Cisco Data Center 3.0 Ordering Guide ADC-APC Integrated Cisco Data Center Solutions The evolution of data centers is happening before our eyes. This is due to the

More information

EATS16 EATS16N. Installation and user manual ENGLISH. Copyright 2015 EATON All rights reserved.

EATS16 EATS16N. Installation and user manual ENGLISH. Copyright 2015 EATON All rights reserved. ENGLISH EATS6 EATS6N Installation and user manual Copyright 05 EATON All rights reserved. Service and suppt: Call your local service representative SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. This manual

More information

InstaPATCH ZERO Solution Guide

InstaPATCH ZERO Solution Guide SYSTIMAX Solutions InstaPATCH ZERO Solution Guide Rapid Server Deployment and Change Management North, South and Central Americas 1 As data centers face ever-increasing IT demands, growth demands and evolving

More information

Ahead in power distribution

Ahead in power distribution Ahead in power distribution DEDICATED SOLUTIONS FOR POWER DISTRIBUTION AND MONITORING IN DATA CENTERS 2 A tradition in innovation AMBACHTSSTRAAT 12, 3861 RH NIJKERK, THE NETHERLANDS I T +31 33 245 23 60

More information

Application Briefs: Remote Office Environment

Application Briefs: Remote Office Environment Overview Remote offices are a definite sign of growth, but it can constitute an immense challenge from an IT infrastructure standpoint. Remote offices may include a wide variety of wiring closets and small

More information

TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial MODEL NUMBER: SM1000RM1UTAA Description Tripp Lite SM1000RM1UTAA 1000VA / 1kVA / 800 watt line

More information

1.44 kw Programmable DC Power Supplies XLN Series

1.44 kw Programmable DC Power Supplies XLN Series Data sheet 1.44 kw Programmable DC Power Supplies XLN Series New Family of High Density System Power Supplies The B&K Precision XLN series are compact, programmable, single-output DC power supplies, suitable

More information

Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers

Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers An intelligent physical infrastructure is required

More information

EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS EMC Data Domain deduplication storage systems continue to revolutionize disk backup, archiving, and disaster recovery with high-speed, inline deduplication.

More information

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial MODEL NUMBER: SMART2200RM2U Highlights 2.2kVA / 2200VA / 1920W line interactive 2U

More information

How To Upgrade An Hp Power Distribution Rack To A Power Distribution Unit

How To Upgrade An Hp Power Distribution Rack To A Power Distribution Unit Overview Power protection in the data center is critical to maintain up time, and the increased densities in data centers is driving the need for uninterruptible power with increased power density, power

More information

Power Distribution Solutions for the Data Center Equipment Cabinet THE WORLD LEADER IN POWER MANAGEMENT PRODUCTS & SOLUTIONS

Power Distribution Solutions for the Data Center Equipment Cabinet THE WORLD LEADER IN POWER MANAGEMENT PRODUCTS & SOLUTIONS > POWERSOLUTIONS CDU Product Family Power Distribution Solutions for the Data Center Equipment Cabinet THE WORLD LEADER IN POWER MANAGEMENT PRODUCTS & SOLUTIONS Cabinet power distribution units and power

More information

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410 The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a

More information

RACK ENCLOSURES & ACCESSORIES

RACK ENCLOSURES & ACCESSORIES RACK ENCLOSURES & ACCESSORIES RACK ENCLOSURES NetshelterTM 1 NetShelter VX / NetShelter VS 2 Open Frame Racks 3 NetShelter ES 4 NetShelter WX Part Number Model Height Width Depth Color Application Doors

More information

A QUICK AND EASY GUIDE TO SETTING UP THE DELL POWEREDGE C8000

A QUICK AND EASY GUIDE TO SETTING UP THE DELL POWEREDGE C8000 A QUICK AND EASY GUIDE TO SETTING UP THE DELL POWEREDGE C8000 A Principled Technologies setup guide commissioned by Dell Inc. TABLE OF CONTENTS Table of contents... 2 Introduction... 3 Dell 42U rack...3

More information

Packet Power. Data Center Solutions. Packet Power for Data Centers. Benefits. Features. The Packet Power Solution. Data Center Monitoring Made Easy

Packet Power. Data Center Solutions. Packet Power for Data Centers. Benefits. Features. The Packet Power Solution. Data Center Monitoring Made Easy Data Center Solutions Packet Power for Data Centers Packet Power provides the easiest, most cost-effective way to capture detailed power and temperature information for both single-site and large multi-facility

More information

Cabinet V800 V800 CABINETS

Cabinet V800 V800 CABINETS V800 Cabinet Siemon s V800 cabinets provide a robust, cost-effective enclosure solution that provides valuable Zero-U space on each side of the equipment rails for cable management, PDU mounting or connectivity

More information

TSM Series Serial Console Servers. RSM Series Remote Site Managers. RSM-xRy Series Remote Site Managers with Power Control.

TSM Series Serial Console Servers. RSM Series Remote Site Managers. RSM-xRy Series Remote Site Managers with Power Control. WTI Part No. 14023 Rev. O TSM Series Serial Console Servers RSM Series Remote Site Managers RSM-xRy Series Remote Site Managers with Power Control Products Covered: TSM Series RSM Series RSM-xRy Series

More information

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out APC Matrix-UPS, 3750 Watts / 5000 VA,Input 208V / Output 120V, 208V, Interface Port DB-9 RS-232, SmartSlot, Extended runtime model Includes: CD with software,

More information

Introducing Tripp Lite s PowerAlert Network Management Software

Introducing Tripp Lite s PowerAlert Network Management Software Introducing Tripp Lite s PowerAlert Network Management Software What Can It Do For You? Improve the accuracy and efficiency of the network operations staff in the context of power and environmental management

More information

HP R12000 and R18000 DirectFlow UPS User Guide

HP R12000 and R18000 DirectFlow UPS User Guide HP R12000 and R18000 DirectFlow UPS User Guide Abstract This document includes installation, configuration, and operation information for the HP R12000 and R18000 DirectFlow UPS. This document is for the

More information

EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS EMC Data Domain deduplication storage systems continue to revolutionize disk backup, archiving, and disaster recovery with high-speed, inline deduplication.

More information

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual 5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...

More information

Data Sheet FUJITSU PRIMECENTER M2 19-inch Racks

Data Sheet FUJITSU PRIMECENTER M2 19-inch Racks Data Sheet FUJITSU PRIMECENTER M2 19-inch Racks Data Sheet FUJITSU PRIMECENTER M2 19-inch Racks 19-inch Industry Standard Rack Systems The trend to consolidation as a result of virtualization and optimization

More information

Emerson Network Power Rack PDU Solutions Rack Power Distribution For Critical IT Equipment. AC Power For Business-Critical Continuity

Emerson Network Power Rack PDU Solutions Rack Power Distribution For Critical IT Equipment. AC Power For Business-Critical Continuity Emerson Network Power Rack PDU Solutions Rack Power Distribution For Critical IT Equipment AC Power For Business-Critical Continuity Enhanced Performance And Management Of Dynamic IT Spaces IT space is

More information

Considerations for a Highly Available Intelligent Rack Power Distribution Unit. A White Paper on Availability

Considerations for a Highly Available Intelligent Rack Power Distribution Unit. A White Paper on Availability Considerations for a Highly Available Intelligent Rack Power Distribution Unit A White Paper on Availability Introduction Data centers are currently undergoing a period of great change. Data center managers

More information

PX Intelligent Rack PDUs

PX Intelligent Rack PDUs PX Intelligent Rack PDUs Rack Power Distribution Units for Your Data Center Raritan s PX intelligent rack PDU series offers more than just power distribution -- it s a launch pad for real-time remote power

More information

Rack Power Distribution Unit For Critical IT Equipment

Rack Power Distribution Unit For Critical IT Equipment AC Power for Business-Critical Continuity Rack Power Distribution Unit For Critical IT Equipment One Move Ahead With Emerson Network Power Emerson Network Power, a division of Emerson, is a global company

More information