1 SECTION FOUR Table of Contents Page Enclosure Power Distribution Units (PDUs) Single-Phase Basic/Smart PDUs 72 3-Phase Basic/Smart PDUs 73 Single- and 3-Phase Switched PDUs 74 PDU Accessories Mounting, Cord Management and Cord Set 75 PDU Configuration Guide 76 and Configuration Chart 77 Environmental Monitors and Sensors 78 Precisely distribute, monitor, analyze and manage power distribution in your facility to maximize processing capacity and promote power efficiency. Power Availability, Distribution, Allocation and Monitoring are Critical Data Center and Broadcast Studio Requirements Belden in-enclosure mounted Power Distribution Units (PDUs) and Environment Monitors and Sensors are designed from highquality components to support all your mission critical applications. A key component of our Data Center Ready Solution (DCRS), Belden PDUs allow configuration of integrated and optimized hosting systems, including fiber/copper connectivity and cabling, enclosures, cable management and air flow management. They are designed to facilitate seamless integration into Belden enclosures and racks, and include multiple mounting options for maximized air flow and cable management in high-density servers or switch hosting applications. Paired with our extensive line of environmental monitors and sensors, which include alarm thresholds, reporting functionality, and a built-in intuitive web interface for remote access, Belden has everything you need to precisely monitor, analyze and log key parameters, enabling you to identify current fluctuations and quickly troubleshoot potential problems.

2 Enclosure Power Distribution Units (PDUs) Belden PDU Options and Features All Belden PDUs are UL and cul listed Select from a wide offering of PDUs designed to meet your specific power requirements; single phase, 3-phase (WYE and Delta configurations) Power Amp Voltage Phase 3.3kW A V 1 Phase L6-P or 5kW A V 1 Phase L6-P or 11kW A 2/400V 3 Phase WYE L22-P or 4P, 5W 16.6kW A 2/400V 3 Phase WYE L22-P or 4P, 5W 1.4kW 15A V 1 Phase 5-15P or L5-15P 1.9kW A V 1 Phase 5-P or L5-P 2.8kW A V 1 Phase L5-P 5.7kW A 1/8V 3 Phase WYE L21-P 8.6kW A 1/8V 3 Phase WYE L21-P 8.6kW A V 3 Phase Delta L15-P 17.2kW 60A 8V 3 Phase Delta 3P/4W 23kW 80A 8V 3 Phase Delta Hard Wired 34kW 1A 8V 3 Phase Delta Hard Wired Over 500 standard PDUs available to ship within 10 days of ordering, or custom PDUs available to ship within days of ordering C-13 and C-19 receptacles with optional locking feature for mission critical applications Unplugging cords requires simple push of release button Locking mechanism binds to the ground pin on the plug and is compatible with standard IEC cord, thus eliminating the need for expensive proprietary cords XN Series enclosures with end-of-row and in between 6" extensions Locking s Organized networking and power cable management for proper server airflow Side-by-side PDU mounting using 7" wide PDU mounting panel (Part. XVMP024501) Inside View of Locking Mechanism BELDEN.1 ( )

3 Faster. Easier. Better. Enclosure Power Distribution Units (PDUs) (continued) PDU Selection: Basic, with Local Monitoring and Intelligent PDU mounted display option for local current or power monitoring, making phase balancing easier (the PDU itself is not phase balancing) Intelligent PDU Options and Features Remote aggregate, circuit or receptacle power monitoring for granular PUE measurement Switched (on/off) options allow remote outlet management and equipment reboot with sequential delay features; avoid power interruption due to inrush current, equipment start up in desired sequence Highly secure access with admin, control and view-only accounts Intuitive Ethernet-based firmware with alarm or SNMP trap features prevents downtime with early notification of power threshold breaches SNMP (MIB) enabled for compatibility with all leading DCiM packages Integrated environmental monitoring capabilities; monitor temperature, air flow, humidity and dew point via optional connected sensors Internal memory for up to two week of trending of critical parameters for clear understanding of power allocation and usage PDU Firmware, Trending Page Intelligent-Remote Monitoring (3) Belden PDU tes: Local Display/ Monitoring (1) Local current/amp meter, monitoring at circuit level for multi-circuit PDU. (2) Local power meter provides Amps, Volts, Watts, Volt-Amps, kwh and Power Factor. (3) Remote functions (IP-based) accessible via web browser. Current Power Circuit Level Environmental Port (4) Power Outlet Level (5) (4) Remote IP-based environmental monitoring, (2) port per PDU. Requires external sensor, refer to accessories (p. 78) for selection. (5) Remote IP-based receptacle level monitoring, Amps, Volts, Watts, kwh. (6) Remote IP-based receptacle level switching (on/off) with configurable time delay. Outlet Switched (6) Basic (B) Local (L) Current (C) (1) Power (P) (2) Power Outlet (O) (2) Switched (S) (2) Optional Power, Cooling and Air Handling Relations PDU Firmware, Alarm Setting Page Intelligent PDU Communication and Environmental Monitoring Ports PDU Nameplate Current Rating (A) Branch Circuit Rating (A) Nameplate Volts (V) Volts Actual Delivered (V) Phase* PDU minal Power Watts (W) PDU De-Rated Power (W) PDU De-Rated Power (kw) PDU De-Rated Power (BTU/hr.) AC Tons** (BTU/100) Air Volume*** (1 CFM* kw) ,800 1, , ,400 1, , ,600 2, , ,160 3, , ,240 4, , ,400 7, , ,480 9, , , ,600 3, , ,900 5, , ,800 11, , ,3 16 1/ ,197 5, , / ,795 8, , , / ,992 12, , , / ,616 17, , , / ,027 28, , , / ,033 36, , , / ,040 43, , , / ,856 11, , ,3 24 2/ ,785 16, , ,992 *3-Phase power is calculated by multiplying single phase by the square root of 3 or **Tons of air conditioning required to remove heat from associated IT load. ***The volume of air that is typically required by the IT equipment for each kw of IT load can typically range from 80 to 140 CFM BELDEN.1 ( ) 71

4 Single-Phase PDUs Front View 9LF Rear View 9LF UL Listed Single-Phase PDUs : B = Basic; L = Local Monitored 9LB De-Rated Amps (A)/ Power (kw) Volts (V) Total Thermal /Qty Circuit Breaker On-Off Switch Surge Monitoring- Supression Local Mounting (4) L x W x D (in.) 9BF B /1 5-15P R/6 Rack - 19" 17 x 1.72 x BF B /1 5-15P R/6 Rack - 19" 17 x 1.72 x BF B /1 5-15P R/8 Vertical 24 x 1.61 x LF L /1 5-15P R/10 Power Rack - 19" 17 x 1.72 x 4.5 9BF B /1 5-15P R/14 Vertical 47.5 x 1.61 x BG B 1.9 /1 L5-P 8 5-R/8 Vertical 24 x 1.61 x BG B 1.9 /1 L5-P 10 5-R/10 Rack - 19" 17 x 1.72 x LG B 1.9 /1 L5-P 10 5-R/10 Power Rack - 19" 17 x 1.72 x 4.5 9BG B 1.9 /1 L5-P 14 5-R/14 Vertical 47.5 x 1.61 x BG B 1.9 /1 L5-P 14 5-R/14 Vertical 47.5 x x BG B 1.9 /1 L5-P 14 5-R/14 Vertical 47.5 x x BG B 1.9 /1 L5-P 14 5-R/14 Vertical 47.5 x x LH L 2.8 /1 L5-P 24 5-R/24 Magnetic Breaker Power Vertical 9LB L 5 /8 L6-P 12 C-13/12 Magnetic Breaker Power Rack - 19" 17 x 1.72 x 6.5 9LB L 5 /8 L6-P C-13/24 + C-19/6 Magnetic Breaker Power Vertical tes: in part # (ex: 9PB2-dd01 would be 9PB = 8 ft). Available in 2, 4, 6, 8, 10, 15, ft. (2) Standard cord exits from chassis face; top of chassis exit (3) Standard PDU chassis color is black, custom color overlay Front View 9PG Rear View 9PG UL Listed Single-Phase PDUs : P = Remote Power Monitored; O = Outlet Monitored tes: De-Rated Amps (A)/ Power (kw) Volts (V) in part # (ex: 9PB2-dd01 would be 9PB = 8 ft). Available in 2, 4, 6, 8, 10, 15, ft. Total /Qty 9OB Thermal Circuit Breaker (2) Standard cord exits from chassis face; top of chassis exit (3) C-13L, L refers to receptacles with locking feature. On-Off Switch Monitoring-Local/ Remote Environmental Monitoring (4) Standard PDU chassis color is black, custom color overlay (5) These PDUs have no Surge Supression. Mounting (4) L x W x D (in.) 9PG P 1.9 /1 5-P 10 5-R/ Magnetic Power/Aggregate - 2 Port Rack - 19" 17 x 1.72 x 6.5 9PB P 5 /8 L6-P C-13/24 + C-19/6 Magnetic Breaker Power/Circuit Breaker - 2 Port Vertical.25 9PB P 5 /8 L6-P C-13L/24 + C-19L/6 Magnetic Breaker Power/Circuit Breaker - 2 Port Vertical 72 x 2 x PB P 5 /8 L6-P 42 C-13/36 + C-19/6 Magnetic Breaker Power/Circuit Breaker - 2 Port Vertical 70 x 2 x OB O 5 /8 L6-P 24 C-13L/18 + C-19L/6 Magnetic Breaker Power/Circuit Breaker + Outlet - 2 Port Vertical 72 x 2.25 x BELDEN.1 ( )

5 Faster. Easier. Better. 3-Phase PDUs 9LI UL Listed 3-Phase PDUs : B = Basic; L = Local Monitored ZPB IBBPS15 De-Rated Amps (A) Power (kw) x Phases Input Volts (V)/ Output Volts (V) Total /Qty(s) Circuit Breaker (Amp/Qty) Monitoring- Local/Remote Mounting L x W x D (in.) 9LI L 5.7 x 3 Ph. 1/8 WYE/8 L21-P C-13/24 + C-19/6 Amp (X,Y,Z)/ Vertical 9LJ L 8.6 x 3 Ph. 1/8 WYE/8 L21-P C-13/24 + C-19/6 /3D Amp (X,Y,Z)/ Vertical 9LJ L 8.6 x 3 Ph. 1/8 WYE/1 & 8 L21-P 33 C-13/24 + C-19/3 /3D Amp (X,Y,Z)/ Vertical 9LC L 11 x 3 Ph. 2/400 WYE/2 L22-P C-13/24 + C-19/6 + 5-R/6 Amp (X,Y,Z)/ Vertical 9LC L 11 x 3 Ph. 2/400 WYE/2 4P, 5W C-13/24 + C-19/6 Amp (X,Y,Z)/ Vertical 9LD L 16.6 x 3 Ph. 2/400 WYE/2 L22-P C-13/24 + C-19/6 /3D Amp (X,Y,Z)/ Vertical 9LD L 16.6 x 3 Ph. 2/400 WYE/2 4P, 5W C-13/24 + C-19/6 /3D Amp (X,Y,Z)/ Vertical 9BL B x 3 Ph. 8 Delta/8 12 C-19/ /6 Breaker/ Rack - 19" 9BL B x 3 Ph. 8 Delta/8 24 C-13/12 + C-19/12 /6 Breaker/ Vertical tes: in part # (ex: 9PB2-dd01 would be 9PB = 8 ft). Available in 2, 4, 6, 8, 10, 15, ft. (2) Standard cord exits from chassis face; top of chassis exit (3) C-13L, L refers to receptacles with locking feature. (4) Ex: /3D, D refers to double pole breakers (A in this case). (5) Standard PDU chassis color is black, custom color overlay 17 x 3.4 x x 2.3 x 3.45 (6) These PDUs have no Surge Supression or On/Off Switch. (7) PDU Dog House hosts the circuit breaker and protrude from the PDU chassis by 1.44". 9PC OJ UL Listed 3-Phase PDUs : C = Remote Current Monitored; P = Power Monitored; O = Outlet Monitored De-Rated Amps (A) Power (kw) x Phases Input Volts (V)/ Output Volts (V) Total 9PC P 5.8 x 3 Ph. 1/8 WYE/8 L21-P 44 /Qty(s) C-13/36 + C-19/6 + 5-R/2 Circuit Breaker (Amp/Qty) (4) Monitoring- Local/Remote Environ. Monitoring Power/X, Y, Z - 2 Port 9CJ C 8.6 x 3 Ph. 1/8 WYE/8 L21-P C-13/24 + C-19/6 /3D Current/Current 9OJ O 8.6 x 3 Ph. 1/8 WYE/8 L21-P C-13L/24 + C-19L/6 /3D 9OC O 11 x 3 Ph. 2/400 WYE/2 L22-P 24 C-13L/18 + C-19L/6 9OD O 16.6 x 3 Ph. 2/400 WYE/2 4P, 5W 24 C-13L/18 + C-19L/6 /6 Power/X, Y, Z + Outlet Power/X, Y, Z + Outlet Power/X, Y, Z + Outlet - 2 Port - 2 Port - 2 Port 9PL P x 3 Ph. 8 Delta/8 4P, 4W C-13/24 + C-19/6 /6D Power/X, Y, Z - 2 Port tes: in part # (ex: 9PB2-dd01 would be 9PB = 8 ft). Available in 2, 4, 6, 8, 10, 15, ft. (2) Standard cord exits from chassis face; top of chassis exit (3) C-13L, L refers to receptacles with locking feature. (4) Ex: /3D, D refers to double pole breakers (A in this case). (5) Standard PDU chassis color is black, custom color overlay L x W x D (in.) 70 x 2 x x 2.25 x x 2.25 x x 2.3 x 3.45 (6) These PDUs have no Surge Supression or On/Off Switch. (7) PDU Dog House hosts the circuit breaker and protrude from the PDU chassis by 1.44". (8) All these 3-Phase PDUs are vertically mounted BELDEN.1 ( ) 73

6 Single- and 3-Phase PDUs Front View 9SG Rear View 9SG UL Listed Single- and 3-Phase PDUs : S = Remotely Switched 9SJ SJ De-Rated Amps (A) Power (kw) x Phases Input Volts (V)/ Output Volts (V) Total / Circuit Breaker Qty(s) (Amp/Qty) (4) Monitoring-Local/ Remote Mounting (5) 9SG S 1.9 1/1 5-P 8 5-R/8 Power/Agg Power Rack - 19" 9SG S 1.9 or or 8/1 or 8 C- 8 C-13L/8 Power/Agg + Outlet Rack - 19" 9SB S 5 8/8 L6-P 24 9SJ S 8.6 x 3 Ph. 1/8 WYE/8 L21-P 24 9SJ S 8.6 x 3 Ph. 1/8 WYE/8 L21-P 24 9SC S 11 x 3 Ph. 2/400 WYE/2 24 9SC S 11 x 3 Ph. 2/400 WYE/2 24 9SC S 11 x 3 Ph. 2/400 WYE/2 L22-P 24 9SC S 11 x 3 Ph. 2/400 WYE/2 L22-P 24 9SD S 16.6 x 3 Ph. 2/400 WYE/2 4P, 5W 24 9SD S 16.6 x 3 Ph. 2/400 WYE/2 4P, 5W 24 9SD S 16.6 x 3 Ph. 2/400 WYE/2 L22-P 24 9SD S 16.6 x 3 Ph. 2/400 WYE/2 L22-P 24 9SL S x 3 Ph. 8 Delta/8 24 9SL S x 3 Ph. 8 Delta/8 24 C-13L/ + C-19L/4 C-13L/18 + C-19L/6 C-13L/18 + C-19L/6 C-13L/18 + C-19L/6 C-13L/18 + C-19L/6 /2D Power/Agg, Circuit, Outlet Vertical /3D Power/Agg, Circuit Vertical /3D Power/Agg, Circuit, Outlet Vertical Power/Agg, Circuit Vertical Power/Agg, Circuit, Outlet Vertical Power/Agg, Circuit Vertical Power/Agg, Circuit, Outlet Vertical /6 Power/Agg, Circuit Vertical /6 Power/Agg, Circuit, Outlet Vertical /6 Power/Agg, Circuit Vertical /6 Power/Agg, Circuit, Outlet Vertical /6D Power/Agg, Circuit Vertical /6D Power/Agg, Circuit, Outlet Vertical L x W x D (in.) 17 x 1.72 x x 1.72 x x 2.5 x x 2.5 x x 2.5 x x 2.5 x x 2.5 x x 2.5 x x 2.5 x x 2.5 x x 2.5 x x 2.5 x x 2.5 x x 4 x x 4 x 3.45 tes: in part # (ex: 9PB2-dd01 would be 9PB = 8 ft). Available in 2, 4, 6, 8, 10, 15, ft. 9SG Power Cord is sold separately. (2) Standard cord exits from chassis face; top of chassis exit (3) C-13L, L refers to receptacles with locking feature. (4) Ex: /3D, D refers to double pole breakers (A in this case). (5) Standard PDU chassis color is black, custom color overlay (6) These PDUs have no On/Off Switch or Surge Supression. (7) PDU Dog House hosts the circuit breaker and protrude from the PDU chassis by 1.44". (8) All these Single- and 3-Phase PDUs have a Switched Outlet and a 2-port Environmental Monitor BELDEN.1 ( )

7 Faster. Easier. Better. PDU Accessories Mounting, Cord Management and Cord Set Description Belden Part Number Tool-Less PDU Mounting Panel (for XM and XS Style Enclosures) Vertical Manager/PDU Mount Panel, 3.5"W, 42RU, Black Vertical Manager/PDU Mount Panel, 3.5"W, 45RU, Black Vertical Manager/PDU Mount Panel, 3.5"W, 48RU, Black Vertical Manager/PDU Mount Panel, 7"W, 42RU, Black Vertical Manager/PDU Mount Panel, 7"W, 45RU, Black Vertical Manager/PDU Mount Panel, 7"W, 48RU, Black Vertical Manager/PDU Mount Panel, 3.5"W, 42RU, White Vertical Manager/PDU Mount Panel, 3.5"W, 45RU, White Vertical Manager/PDU Mount Panel, 3.5"W, 48RU, White Vertical Manager/PDU Mount Panel, 7"W, 42RU, White Vertical Manager/PDU Mount Panel, 7"W, 45RU, White Vertical Manager/PDU Mount Panel, 7"W, 48RU, White Tool-Less PDU Mounting Panel (for XN Style Enclosures) XVMP0141 XVMP XVMP XVMP0241 XVMP XVMP XVMP0142 XVMP XVMP XVMP0242 XVMP XVMP " Lacing Panel 3.5" Lacing Panel PDU Mounting Bracket Double, Post Mounting 2 PDU Side-by-Side Facing Into Enclosure PDU Mounting Bracket Single, Rear Facing Pair PDU Mounting Bracket Rear Facing Pair Between Frames PDU Mounting Bracket Rear Facing Pair Between Frames with Extension Vertical Manager Panel, 42RU X 7.0"W, Black Vertical Manager Panel, 45RU X 7.0"W, Black Vertical Manager Panel, 48RU X 7.0"W, Black Vertical Manager Panel, 42RU X 7.0"W, CO White Vertical Manager Panel, 45RU X 7.0"W, CO White Vertical Manager Panel, 48RU X 7.0"W, CO White Tool-Less PDU Mounting Panel (for XSS Seismic Enclosures) Cable PDU Manager Rear Panel, 44RU, Rear, Black Cable PDU Manager Rear Panel, 44RU, Rear, with 6 Rings, Black Cable PDU Manager Rear Panel, 44RU, Rear, CO White Cable PDU Manager Rear Panel, 44RU, Rear, with 6 Rings, CO White Tool-Less PDU Mounting Panel (for XSN Seismic Enclosures) Cable PDU Manager Rear Panel, 44RU, Rear, Black Cable PDU Manager Rear Panel, 44RU, Rear, with 6 Rings, Black Cable PDU Manager Rear Panel, 44RU, Rear, CO White Cable PDU Manager Rear Panel, 44RU, Rear, with 6 Rings, CO White Power Cord Management Cable Management Ring Plastic (Qty = 5) 3" x 1.5" Reversible Cable Management Ring Kit (Qty = 5) 2.5"W x 3"D Slack Management Spool Kit (includes 2 spools) Quick Mount Base (Qty=10) with Fastener, for 1/4" Holes Velcro Cable Ties, 25 per Roll, 8" L x 0.5"W Velcro Cable Ties, 25 per Roll, 12" L x 0.5"W Cord Set* (C13/C19, C19/C - UL - cul Listed) C13 to C14 n-locking Cord Set - Y" Long Black C13 to C14 n-locking - 36" Long Black C13 to C14 n-locking - 48" Long Black C19 to C n-locking Cord Set - Y" Long Black C19 to C n-locking - 36" Long Black C19 to C n-locking - 48" Long Black C13 Locking to C14 - " Long Blue C13 Locking to C14 - " Long Orange C19 Locking to C - " Long Blue C19 Locking to C - " Long Orange C13 Locking to C14-39" Long Blue C13 Locking to C14-39" Long Orange C19 Locking to C - 39" Long Blue C19 Locking to C - 39" Long Orange tes: yy = 12, 24, = cord length 12 to 96 inches; 12 inch increments. XNPM01 XNPM02 XNPM03 XNPM04 XNVLP42901 XNVLP45901 XNVLP48901 XNVLP42902 XNVLP45902 XNVLP48902 XSN44VRPM101 XSN44VRPM1 XSN44VRPM102 XSN44VRPM2 XSN44VRPM101 XSN44VRPM1 XSN44VRPM102 XSN44VRPM2 XMR01 XMR03 XSK0 XCTM AX AX CSC13C14yyBK CSC13C1436BK CSC13C1448BK CSC19CyyBK CSC19C36BK CSC19C48BK CSLC13C14BL CSLC13C14OR CSLC19CBL CSLC19COR CSLC13C1439BL CSLC13C1439OR CSLC19C39BL CSLC19C39OR Mounting Brackets Cable Management Ring (Plastic) Cord Set *tes: (applies to Cord Set [above]) Quick Mount Base Built within the plug housing on the female end (C13/C19) of the cord, the patented integrated locking mechanism is protected against vibration and external elements that can easily dislodge other plug securing solutions, like external locking clips and guides. This self-contained locking mechanism engages with any standard IEC male connector (C14/C). The cord locking feature is only available at the device-end of the cord sets. A power strip with locking receptacles must be available to secure these cords to the PDU BELDEN.1 ( ) 75

8 Power Distribution Unit Configuration Guide Please select the desired configuration and specifications and submit to Belden. Power Availability Quantity Required First Unit Required by Date Electrical Configuration Power Input Quantity** Input S Input 5-15P 15 tes: *Rating for CE Products L5-15P 15 5-P L5-P 6-P L6-P L14-P / L21-P x 3~ 1/8 WYE L5-P L6-P L14-P / L15-P x 3~ Delta L21-P x 3~ 1/8 WYE IEC C- Inlet ( Cord) 2 Pole/3 Wire 3 Pole/4 Wire 2 Pole/3 Wire 3 Pole/4 Wire 2 Pole/3 Wire 3 Pole/4 Wire Cord Length **Quantity = # of Circuits /16* or /16* /2* 3~ /32* /2* 3~ 60/63* /2* 60 3~ Phone Target Price Comparable Competitive Unit Brand/Model# Power Input Quantity S 5-15R Duplex R Individual 15 L5-15R Duplex 15 5-R Duplex 5-R Individual L5-R 6-R Duplex Physical Configuration Dimensional Limits L6-R L5-R L6-R IEC C-13 15/10* or IEC C-19 /16* or Length Width Height Hardwire Options Quantity** Additional Information Other - Please Specify Mounting Orientation 6" Wire Tails with Removable Plate Flexible Conduit Terminal Block Horizontal Vertical Project Timeline Power Switch Monitoring - with Cover Current Local - Current (Amps) Only - Scrolling Display (Volts, Amps, Watts, Power Factor) Environmental Circuit Breakers (required by NEC in some units) 3rd Party Testing - Compliance UL Listed Surge Supression Current Remote - Circuit Level - Outlet Level Remote Switching Isolated Ground UR - UL Recognized FCC Part 15 Class A CE ne Required Other - Please Specify BELDEN.1 ( )

9 Faster. Easier. Better. and Configuration Chart NEMA s and s Straight-Blade P 5-15R 5-P 5-R 15 L5-15P L5-15R 1/8 x 3~ WYE L21-P L21-R L5-P L5-R 2/400 x 3~ WYE L22-P L22-R L5-P L5-R 1/8 x 3~ WYE L21-P L21-R L6-P L6-R 2/400 x 3~ WYE L22-P L22-R L6-P L6-R x 3~ Delta L15-P L15-R / L14-P L14-R / L14-P L14-R 50 x 3~ Delta /16* or Twist-Lock Straight-Blade Twist-Lock Straight-Blade Straight-Blade 6-P 6-R Twist-Lock Twist-Lock California Style IEC s and s Power Inlet Power 15/10* or /16* /2* 60/63* /2* 60 /32* /2 /16* 2/400* x 3~ WYE 4P, 5W 4P, 5W /32* 2/400* x 3~ WYE 4P, 5W 4P, 5W C-14 C-13 Pin & Sleeve Power Inlet Power C- C-19 Pin & Sleeve *Rating for CE Products What is 3-Phase WYE? 3-Phase Delta from 8V Source 3-Phase Delta from 1/8V Source X Phase X Phase Ground Z Phase Y Phase 8V (XY) Z Phase Ground L21-P 8V (XY) Y Phase 8V (ZX) 8V (ZX) Y Phase 1V (XN) 8V (YZ) A 3-Phase Delta is a 4-wire configuration consisting of 3-Phase conductors (X, Y and Z) and a Ground. Without the neutral present, only phase-to-phase wiring is possible. The potential between any 2-Phase conductors is typically 8V. 3 Phase WYE 3 Phase Delta X Phase Neutral L15-P A 3-Phase Delta 1/8V WYE is a 5-wire configuration consisting of 3-Phase conductors (X, Y and Z), Neutral and Ground. The potential between any 2-Phase conductors is 8V. The potential between any phase and neutral is 1V. This configuration can be wired to provide 1V, 8V or a combination of both voltages within one PDU BELDEN.1 ( ) What is 3-Phase Delta? 8V (YZ) Z Phase 1V (YN) 1V (ZN) Neutral Ground 77