System 2 mm Reaction in case of fire: Resistance to fire 1 NPD Reaction to fire 3,4 A1 External fire performance 3,4 NPD

Size: px
Start display at page:

Download "System 2 mm Reaction in case of fire: Resistance to fire 1 NPD Reaction to fire 3,4 A1 External fire performance 3,4 NPD"

Transcription

1 System 2 mm Wind, snow, permanent and imposed load resistance [mm] 4 2 Direct airbone sound insulation (EN 12758) [db] 4 NPD

2 System 3 mm Wind, snow, permanent and imposed load resistance [mm] 4 3 Direct airbone sound insulation (EN 12758) [db] 4 29 (-2;-5)

3 Thermally toughened patterned glass: EcoSolar MM eisenarm System 3 mm Wind, snow, permanent and imposed load resistance [mm] 4 3 Direct airbone sound insulation (EN 12758) [db] 4 29 (-2;-5)

4 System 4 mm Wind, snow, permanent and imposed load resistance [mm] 4 4 Direct airbone sound insulation (EN 12758) [db] 4 29 (-1;-3)

5 Thermally toughened patterned glass: EcoSolar MM eisenarm System 4 mm Wind, snow, permanent and imposed load resistance [mm] 4 4 Direct airbone sound insulation (EN 12758) [db] 4 29 (-1;-3)

EN 1279-5. Insulating glass units, intended to be used in buildings and construction works

EN 1279-5. Insulating glass units, intended to be used in buildings and construction works 4 (#2) - 12-4, Thermally Toughened Heat and Solar Control Glass 1 (C) 3-12 - 4-12 - 4 29 (-1; -4) db U-value (EN 673) 1,6 W / (m 2 K) Light transmission and reflection 0,71/0,10/0,11 Solar energy characteristics

More information

Trakya Cam Sanayii A.Ş. Adres: İş Kuleleri Kule 3 34330 4.Levent- İSTANBUL/TÜRKİYE 07 EN 1279-5

Trakya Cam Sanayii A.Ş. Adres: İş Kuleleri Kule 3 34330 4.Levent- İSTANBUL/TÜRKİYE 07 EN 1279-5 4 (#2) - 12-4, Thermally Toughened ISS114 #2 + Dry Air (%100) + Clear 1(C) 3-12 - 4-12 - 4 29 (-1; -4) db U-value (EN 673) 2,6 W / (m 2 K) Light transmission and reflection 0,14/0,34/0,37 Solar energy

More information

Trakya Cam Sanayii A.Ş. Adres: İş Kuleleri Kule 3 34330 4.Levent- İSTANBUL/TÜRKİYE 07 EN 1279-5

Trakya Cam Sanayii A.Ş. Adres: İş Kuleleri Kule 3 34330 4.Levent- İSTANBUL/TÜRKİYE 07 EN 1279-5 4-12 - 33.1, Thermally Toughened Helio Blue + Dry Air (%100) + Pendulum body impact resistance 1(C)3-12 - 2 (B) 2 4-12 - 33.1 32 (-1; -3) db U-value (EN 673) 2,8 W / (m 2 K) Light transmission and reflection

More information

EN 1279-5. Insulating glass units, intended to be used in buildings and construction works

EN 1279-5. Insulating glass units, intended to be used in buildings and construction works 4-12 - 4 (#3), Thermally Toughened Helio Blue + Dry Air (100%) + 1(C)3-12 - 4-12 - 4 29 (-1; -4) db U-value (EN 673) 1,6 W / (m 2 K) Light transmission and reflection 0,58/0,/0,10 Solar energy characteristics

More information

EN 1279-5. Insulating glass units, intended to be used in buildings and construction works

EN 1279-5. Insulating glass units, intended to be used in buildings and construction works 6 (#1) - 12-4 (#3), Thermally Toughened Tentesol T Blue #1 + Dry 1(C)2-12 - 6-12 - 4 32 (-2; -4) db U-value (EN 673) 1,6 W / (m 2 K) Light transmission and reflection 0,34/0,34/0,18 Solar energy characteristics

More information

DECLARATION OF PERFORMANCE NO. HU-DOP_TN-212-25_001

DECLARATION OF PERFORMANCE NO. HU-DOP_TN-212-25_001 NO. HU-DOP_TN-212-25_001 Product type 212 (TN) 3,5x25 mm EN 14566:2008+A1:2009 NO. HU-DOP_TN-212-35_001 Product type 212 (TN) 3,5x35 mm EN 14566:2008+A1:2009 NO. HU-DOP_TN-212-45_001 Product type 212 (TN)

More information

EN 1279-5. NPD Reaction to fire. NPD External fire behaviour. NPD Bullet resistance. NPD Explosion resistance. NPD Burglar resistance (EN 356)

EN 1279-5. NPD Reaction to fire. NPD External fire behaviour. NPD Bullet resistance. NPD Explosion resistance. NPD Burglar resistance (EN 356) 4 (# 2) - 12-33.1, Heat Control Glass (Low-E #2) + Argon (90%) + Pendulum body impact resistance - 12-2 (B) 2 4-12 - 33.1 32 (-1; -3) db U-value (EN 673) 1,3 W / (m 2 K) Light transmission and reflection

More information

DECLARATION OF PERFORMANCE NO. HU-DOP_TD-25_001

DECLARATION OF PERFORMANCE NO. HU-DOP_TD-25_001 NO. HU-DOP_TD-25_001 Product type TD 3,5x25 mm EN 14566:2008+A1:2009 NO. HU-DOP_TD-35_001 Product type TD 3,5x35 mm EN 14566:2008+A1:2009 NO. HU-DOP_TD-45_001 Product type TD 3,5x45 mm EN 14566:2008+A1:2009

More information

EN 1279-5. Insulating glass units, intended to be used in buildings and construction works

EN 1279-5. Insulating glass units, intended to be used in buildings and construction works 4 (#2) - 12-4, Heat Control Glass (Low-E #2) + Dry Air (100%) + Clear 4-12 - 4 29 (-1; -4) db U-value (EN 673) 1,6 W / (m 2 K) Light transmission and reflection 0,79/0,12/0,12 Solar energy characteristics

More information

EN 1279-5. Insulating glass units, intended to be used in buildings and construction works

EN 1279-5. Insulating glass units, intended to be used in buildings and construction works 4 (#2) - 12-4, Heat Control Glass (Low-E #2) + Argon (90%) + Clear 4-12 - 4 29 (-1; -4) db U-value (EN 673) 1,3 W / (m 2 K) Light transmission and reflection 0,79/0,12/0,12 Solar energy characteristics

More information

EN 1279-5. Insulating glass units, intended to be used in buildings and construction works

EN 1279-5. Insulating glass units, intended to be used in buildings and construction works 4-12 - 4 (#3), Clear Float Glass + Argon (90%) +Heat Control Glass 4-12 - 4 29 (-1; -4) db U-value (EN 673) 1,3 W / (m 2 K) Light transmission and reflection 0,79/0,12/0,12 Solar energy characteristics

More information

CE Marking of Glass products

CE Marking of Glass products CE Marking of Glass products INTRODUCTION... 10 ARTLITE... 11 ARTLITE / ARTLITE DIGITAL HEAT STRENGTHENED... 12 ARTLITE / ARTLITE DIGITAL THERMALLY TOUGHENED OR HEAT SOAKED THERMALLY TOUGHENED... 1 ARTLITE

More information

iku windows the intelligent self cleaning window AUTOMATIC system

iku windows the intelligent self cleaning window AUTOMATIC system iku windows is a aluminium sliding window system with two rails and double thermal breakage. By adding the iku box underneath the window sill it becomes an intelligent window. Functions Automatic opening

More information

SCHOTT PYRANOVA Planline System

SCHOTT PYRANOVA Planline System Schott_050_Pyranova_E_RZ.fh8.07.005 0:50 Uhr Seite HOME T E C H The Planline system The patented glass fixing method is a clear multi- is based on a fire resistant double glazed allows quick and easy replacement

More information

Understanding fire-resistant glazing systems. Presented by Russell Day Technical officer The Glass and Glazing Federation

Understanding fire-resistant glazing systems. Presented by Russell Day Technical officer The Glass and Glazing Federation Understanding fire-resistant glazing systems Presented by Russell Day Technical officer The Glass and Glazing Federation What is important when specifying and installing Fire-resistant? The framing system

More information

Unbeatable energy efficient glass curtain wall system

Unbeatable energy efficient glass curtain wall system Unbeatable energy efficient glass curtain wall system CONTENT Introduction 1 System 2 World Class Engineering 4 Unit Selection 5 Energy Efficiency & Comfort 10 Maximised Installation Efficiency 12 Aesthetics

More information

Heat-treated Glass. GUARDIAN A Company of Vision PATTERNED GLASS HORTICULTURAL GLASS SUN PERFORMANCE GLASS VISION GLASS SILKSCREENED GLASS THIN GLASS

Heat-treated Glass. GUARDIAN A Company of Vision PATTERNED GLASS HORTICULTURAL GLASS SUN PERFORMANCE GLASS VISION GLASS SILKSCREENED GLASS THIN GLASS Heat-treated Heat-treated Glass Glass Heat-treated Glass Heat-treated Heat-treated Glass Glass REFLECTIVE GLASS LAMINATED GLASS TEMPERED GLASS FLOAT GLASS MIRRORS LOW-E GLASS SUNGUARD PATTERNED GLASS HORTICULTURAL

More information

DS/EN 13782 DK NA:2014

DS/EN 13782 DK NA:2014 National Annex to Temporary structures Tents - Safety Foreword This National Annex (NA) is the first Danish NA to EN 13782. This NA enters into force on 2014-10-15 and shall be applied as from 2015-02-01.

More information

STEEL BUILDINGS IN EUROPE. Single-Storey Steel Buildings Part 8: Building Envelope

STEEL BUILDINGS IN EUROPE. Single-Storey Steel Buildings Part 8: Building Envelope STEEL BUILDINGS IN EUROPE Single-Storey Steel Buildings Part 8: Building Envelope Single-Storey Steel Buildings Part 8: Building Envelope 2 - ii Part 8: Building Envelope emissions

More information

Rakennustuotedirektiivin (89/106/EEC) artiklan 10, neuvoston direktiivi 21. joulukuuta 1988, mukaisesti notifioitu tuotehyväksyntälaitos EOTAN JÄSEN

Rakennustuotedirektiivin (89/106/EEC) artiklan 10, neuvoston direktiivi 21. joulukuuta 1988, mukaisesti notifioitu tuotehyväksyntälaitos EOTAN JÄSEN Page 1 of European Technical Approval ETA-10/0359 VTT EXPERT SERVICES OY PL 1001, 02044 VTT Puh. +358 20 722 4911 Telekopio +358 20 722 7003 www.vttexpertservices.fi Rakennustuotedirektiivin (89/106/EEC)

More information

EN 1991-1-6 DK NA:2007

EN 1991-1-6 DK NA:2007 EN 1991-1-6 DK NA:2007 National Annex to Eurocode 1: Actions on structures - Part 1-6: General actions Actions during execution Foreword In connection with the incorporation of Eurocodes into Danish building

More information

Insulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panels KS1000 RW

Insulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panels KS1000 RW Insulated Roof & Wall Panels Trapezoidal Insulated Roof Panels KS1000 RW Overview Kingspan roof panel systems present a superior system compared to conventional multi-part site assembled systems. They

More information

Metal Roofing Practical Design

Metal Roofing Practical Design Metal Roofing Practical Design Metal Roofing Practical Design Learning Outcomes Minimum Requirements Design Resources Low Slope Metal Roofing Design Details Continuously Insulated (Ci) Systems Minimum

More information

Glass partitions SFB 3074

Glass partitions SFB 3074 Glass partitions SFB 3074 Our facade system SFB 3074 is innovative in its design. We have made a great effort to obtain an energy effective system. The future requirements regarding the economical use

More information

LN240(30)P-3-xxx (230-250W poly)

LN240(30)P-3-xxx (230-250W poly) LN240(30)P-3-xxx (230-250W poly) Why Linuo Modules? 100% EL testing before and after lamination 100% plus tolerance(0-+3%) 100% insured by CHUBB Exceptional performance under low solar irradiance imized

More information

Initial Type Testing Report

Initial Type Testing Report Centrum stavebního inženýrství a. s., Praha Centre of Building Construction Engineering, Inc., Prague Accredited Testing Laboratory, Authorised Body, Notified Body, Certification Body workplace Zlín -

More information

Plaisance 24. Sliding Systems. Sapa Building System

Plaisance 24. Sliding Systems. Sapa Building System Plaisance 24 Sliding Systems Sapa Building System Plaisance 24 is Sapa s noninsulated sliding system for windows and doors. Available as one-, two-, three- and fourrail solution. Among its features, there

More information

RACKING AND ATTACHMENT CRITERIA FOR EFFECTIVE MEMBRANE ROOF SYSTEM INTEGRATION Public Version 1: July 9, 2012

RACKING AND ATTACHMENT CRITERIA FOR EFFECTIVE MEMBRANE ROOF SYSTEM INTEGRATION Public Version 1: July 9, 2012 RACKING AND ATTACHMENT CRITERIA FOR EFFECTIVE MEMBRANE ROOF SYSTEM INTEGRATION Public Version 1: July 9, 2012 Commercial rooftops represent the most available, sustainable and secure real estate for new

More information

Avantis 75. Windows & Doors. Sapa Building System

Avantis 75. Windows & Doors. Sapa Building System Avantis 75 Windows & Doors Sapa Building System Avantis 75 is a thermally broken three-chamber window and door system, which sets the highest standards of thermal insulation and stability. Avantis 75

More information

Product information. Schüco Window AWS 65. 03.2009/Web Schüco AWS 65 1-11

Product information. Schüco Window AWS 65. 03.2009/Web Schüco AWS 65 1-11 Schüco Window AWS 65 The basic window system, Schüco Window AWS 65, with a comprehensive range for imaginative designs, is particularly suitable for block constructions with a basic depth of 65 mm. Features

More information

Plaisance 50. Windows and doors. Sapa Building System

Plaisance 50. Windows and doors. Sapa Building System Plaisance 50 Windows and doors Sapa Building System Plaisance 50 is a non-thermally broken system for aluminium windows and doors with a building depth. The system offers a wide range of inward and outward

More information

Florida Building Code, 5th Edition (2014) June 30 th, 2015

Florida Building Code, 5th Edition (2014) June 30 th, 2015 Florida Building Code, 5th Edition (2014) Update June 30 th, 2015 FBC Update, 5 th Edition (2014) Uses 2012 ICC as its Base Code as required by Florida Legislature Causing sections to be changed Books

More information

REPORT ON THE TESTING OF SEALED UNITS TO VERIFY THE IMPACT OF PRESSURE EQUALISATION ON INSULATION VALUES.

REPORT ON THE TESTING OF SEALED UNITS TO VERIFY THE IMPACT OF PRESSURE EQUALISATION ON INSULATION VALUES. REPORT ON THE TESTING OF SEALED UNITS TO VERIFY THE IMPACT OF PRESSURE EQUALISATION ON INSULATION VALUES. Author: Dr D A Oloke (School of Technology and the Built Environment, University of Wolverhampton)

More information

Confort 26. Sliding Systems. Sapa Building System

Confort 26. Sliding Systems. Sapa Building System Confort 26 Sliding Systems Sapa Building System Confort 26 is Sapa s thermally insulated sliding system for windows and doors. Available as two- and three-rail solution. Among its features, there are

More information

Vehicle Circulation Areas - OPT 3 (Rev 00)

Vehicle Circulation Areas - OPT 3 (Rev 00) Vehicle Circulation Areas - OPT 3 (Rev 00) Customer : TACE (Nick Thomas) Processed by : Matt Booth (on behalf of Andrew Glaister) Project description: Rev 00 (14.11.2012) This OPTION 3 calculation has

More information

EUROPEAN STANDARD DRAFT NORME EUROPÉENNE pren 13474-3 EUROPÄISCHE NORM October 2009

EUROPEAN STANDARD DRAFT NORME EUROPÉENNE pren 13474-3 EUROPÄISCHE NORM October 2009 CEN/TC129/WG8 N258E EUROPEAN STANDARD DRAFT NORME EUROPÉENNE pren 13474-3 EUROPÄISCHE NORM October 2009 ICS Descriptors : English version Glass in building - Determination of the strength of glass panes

More information

THERMAL CHARACTERISTICS Nominal operating cell temperature(noct) [ C] 48,2±2 48 Temperature coefficient P MPP [%K] -0,41-0,47 Temperature coefficient I SC [%K] 0,05 0,04 Temperature coefficient U OC [%K]

More information

Harness Your Energy NOW AVAILABLE! the new. ASW-58A-22/30 Solar Thermal Collector

Harness Your Energy NOW AVAILABLE! the new. ASW-58A-22/30 Solar Thermal Collector NOW AVAILABLE! the new ASW-58A-22/30 Solar Thermal Collector The ASW-58A-22/30 series of collectors are available in 22 and 30 tube units. Other sizes are available upon request. Each unit comes complete.

More information

Development Services City of Lawrence, KS

Development Services City of Lawrence, KS Development Services City of Lawrence, KS Building Planning Table R301.2 (1) Climatic & Geographic Design Criteria Building Planning The design criteria for wind speed increased from 90 MPH to 115 MPH.

More information

HV glass suspension insulator U70BS and U70BL type Ball and socket type Standard profile

HV glass suspension insulator U70BS and U70BL type Ball and socket type Standard profile U70BS and U70BL type IEC 60305 U70BS U70BL GOST 27661 ПС70Е ПС70Е Minimum mechanical failing load kn 70 70 Minimum mechanical residual strength kn 56 56 Diameter of the insulating part, D mm 255 255 Nominal

More information

BUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010

BUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010 Building Control Charnwood Borough Council Southfield Road Loughborough LE11 2TN BUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010 Page 1 of 6 PURPOSE: This Guidance

More information

Declaration of Performance DP 1013-1 EN 14351-1:2006+A1:2010 Prestandadeklaration

Declaration of Performance DP 1013-1 EN 14351-1:2006+A1:2010 Prestandadeklaration Windows and patio doors Fönster och fönsterdörrar For use in domestic and commercial locations Användningsområde: Bostäder och lokaler Declaration of Performance DP 1013-1 EN 14351-1:2006+A1:2010 Prestandadeklaration

More information

Design qualification and type approval of PV modules

Design qualification and type approval of PV modules Design qualification and type approval of PV modules TÜV Immissionsschutz und Energiesysteme GmbH Test Centre for Energy technologies May 2003 Design qualification and type approval of PV-modules in accordance

More information

Relieve the pressure with PYRAN S

Relieve the pressure with PYRAN S pic_01: Attractive mirroring effect at the connection between the landmarked warehouse and the new steel and glass structure. pic_02: In a prominent location in Budapest, the visionary structure enhances

More information

High-speed spiral doors for deep-freeze applications. TK Series

High-speed spiral doors for deep-freeze applications. TK Series High-speed spiral doors for deep-freeze applications TK Series 02 TK Series The cold chain for deep-frozen products must never be interrupted during storage and transport. This demands an enormous amount

More information

Analogue addressable devices

Analogue addressable devices Discovery Analogue addressable devices from Channel Safety Systems Discovery Analogue addressable devices Discovery is a range of high-specification, intelligent fire detectors that are developed to meet

More information

Evidence of Performance. Class 2. Class 5A. Class C4 / B4. Test Report No. 15-003655-PR01. ift Rosenheim 16.12.2015

Evidence of Performance. Class 2. Class 5A. Class C4 / B4. Test Report No. 15-003655-PR01. ift Rosenheim 16.12.2015 Evidence of Performance Test Report No. 15-003655-PR01 (PB-A01-02-en-01) Client Product Designation Performance-relevant product details Overall dimensions (W x H) Special features Alüminyum San. Tic.

More information

Test Report No. C829QPEN

Test Report No. C829QPEN Institut für Solartechnik Hochschule für Technik Rapperswil Oberseestrasse 10, CH 8640 Rapperswil Tel +41 55 222 48 21, Fax +41 55 222 48 44 www.solarenergy.ch Ordered by: Westech Components Wuxi Co.,

More information

HARTING Ethernet Cabling 4-poles Overview

HARTING Ethernet Cabling 4-poles Overview Overview RJ45 Connectors [on page 8] System cables [on page 10] Distribution modules and Outlets [on page 20] HARTING PushPull Connectors [on page 22] System cables [on page 24] Panel feed-throughs [on

More information

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings

More information

THERMOSTOP24 System PORTALEX ALUMINIO SA

THERMOSTOP24 System PORTALEX ALUMINIO SA THERMOSTOP24 System is engaged in the extrusion of aluminium profiles of several sizes with more or less complexity, depending on the client's needs. The extrusion of aluminium allows all freedom of design

More information

Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01

Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01 Section Built-up Metal Roofs Rail and bracket system Product: Earthwool FactoryClad range Bu01 Standing seam system Product: Earthwool FactoryClad range and Earthwool Universal Slab Bu02 Built-up Metal

More information

FIREPROOF Panels Trimoterm

FIREPROOF Panels Trimoterm FIREPROOF Panels Trimoterm FIREPROOF Panels Trimoterm Fireproof panels Trimoterm FTV and SNV are particularly convenient for constructing, where very high demands of fire resistance, sound reduction and

More information

STENCA HT PIPE. Quality Insulation made of calcium silicate. www.stenca.com

STENCA HT PIPE. Quality Insulation made of calcium silicate. www.stenca.com STENA HT PIPE Quality Insulation made of calcium silicate LD Heat Fire INsulation WELME T STENA TRADING - Global focus with local service Stenca Trading offers optimal solutions for the offshore, marine,

More information

Suitable for large-area facades, commercial properties, conservatories, extensions plus detached, semi-detached and terraced houses.

Suitable for large-area facades, commercial properties, conservatories, extensions plus detached, semi-detached and terraced houses. Timber-Glass-Composite elements (TGC) Architecture is based on three principles: Firmitas, Utilitas and Venustas. Vitruv, Roman architect Naturalness, energy efficiency and structural flexibility: uniglas

More information

Installation Detailed installation instructions are provided which should be strictly followed.

Installation Detailed installation instructions are provided which should be strictly followed. Specification System 6 The Metal Technology Thermally-Broken Vertical Slide Window has been designed in such a way that its'attractive and clean lines will enhance all types of residential and commercial

More information

Dispelling the Solar Myth - Evacuated Tube versus Flat Plate Panels. W illiam Comerford Sales Manager Ireland Kingspan Renewables Ltd.

Dispelling the Solar Myth - Evacuated Tube versus Flat Plate Panels. W illiam Comerford Sales Manager Ireland Kingspan Renewables Ltd. Dispelling the Solar Myth - Evacuated Tube versus Flat Plate Panels W illiam Comerford Sales Manager Ireland Kingspan Renewables Ltd. 1 The Kingspan Group Energy independent buildings for a sustainable

More information

National Building Code of Canada 2010

National Building Code of Canada 2010 National Building Code of Canada 2010 Emergency Change Issued by the Canadian Commission on Building and Fire Codes The table that follows lists two emergency changes that apply to the National Building

More information

Typical values for a Kapton Polyimide tape wrapped sample, according to NEMA Specifications

Typical values for a Kapton Polyimide tape wrapped sample, according to NEMA Specifications DACRON DACRON GLASS FIBER COVERED MAGNET WIRE CLASS 200 INSULATION DACRON Glass Fiber-covered Magnet Wire is manufactured by serving a combination of glass and Dacron fibers over a bare or film-coated

More information

Evidence of Performance Resistance to wind load Watertightness Air permeability

Evidence of Performance Resistance to wind load Watertightness Air permeability Evidence of Performance Resistance to wind load Watertightness Air permeability Test Report 102 43093/1e Client Product YILDIZPEN PLASTIK SAN. VE TIC. LTD. STI. A.O.S.B 10039 Street No:18 Çigli Izmir Turkey

More information

REHAU TOTAL70 WINDOW AND DOOR SYSTEM SYSTEM DESCRIPTION. www.rehau.co.uk/windows. Building Solutions Automotive Industry

REHAU TOTAL70 WINDOW AND DOOR SYSTEM SYSTEM DESCRIPTION. www.rehau.co.uk/windows. Building Solutions Automotive Industry REHAU TOTAL70 WINDOW AND DOOR SYSTEM SYSTEM DESCRIPTION www.rehau.co.uk/windows Building Solutions Automotive Industry REHAU TOTAL70 THE MORE COMPLETE SYSTEM The REHAU TOTAL70 Window and Door System comprises

More information

Paver glassblocks. Vetro Expo s.r.l. Thame the Light. www.vetroexpo.it. VETRO EXPO srl 23894 Cremella (LC) Version 2008

Paver glassblocks. Vetro Expo s.r.l. Thame the Light. www.vetroexpo.it. VETRO EXPO srl 23894 Cremella (LC) Version 2008 Paver glassblocks Terme Bains les Bains (88) Architetto : De Gastines (Paris IVe) - Impresa : Gros-oeuvre oeuvre : BDW (68) Fotografie: Pavés & Bains les bains: S. Dondicol Mairie de Harnes : P. Kozlowski

More information

Your essential guide to CE Marking

Your essential guide to CE Marking Your essential guide to CE Marking CE marking A guide for window and door fabricators This guide provides essential information that will help you with your preparations for CE marking. A flowchart is

More information

Light-Weight Panels. High quality panels. www.stenca.com

Light-Weight Panels. High quality panels. www.stenca.com Light-Weight Panels High quality panels WELCOME TO STENCA TRADING - Global focus with local service Stenca Trading offers optimal solutions for the offshore, marine, refineries and cogeneration industry.

More information

How To Test A Base Axe

How To Test A Base Axe Scotch-Weld DP760 Product Data Sheet Updated : February 2009 Supersedes: June 2001 Product Description DP760 epoxy adhesive is a non-sag, two-part room temperature curing adhesive designed for use when

More information

EUROPEAN STANDARD EN 343:2003 PROTECTION AGAINST RAIN

EUROPEAN STANDARD EN 343:2003 PROTECTION AGAINST RAIN EUROPEAN STANDARD EN 343:2003 PROTECTION AGAINST RAIN Published by W. L. Gore & Associates Editorial support Petra Jackisch, Zentrum für Sicherheitstechnik, Erkrath, Germany Suitable protection against

More information

Europeiskt Tekniskt Godkännande European Technical Approval

Europeiskt Tekniskt Godkännande European Technical Approval SITAC Box 553 SE 371 23 Karlskrona SWEDEN MEMBER OF EOTA Tfn.: +46-(0)10-516 63 00 Fax: +46-(0)455-206 88 E-mail: info@sitac.se Europeiskt Tekniskt Godkännande European Technical Approval ETA-11/0380 Handelsnamn

More information

Testing Rules for Thermal Conductivity October 2015

Testing Rules for Thermal Conductivity October 2015 Testing Rules for Thermal Conductivity October 2015 Testing Rules for Thermal Conductivity (October 2015) 1 Normative references (to be inserted as additional chapter in the Testing Rules for Panels) 1.

More information

PCB transformers. Short circuit proof PCB transformer VB. General Data. Advantages. Applications. Circuit diagram. Standards & 1 Certifications W v

PCB transformers. Short circuit proof PCB transformer VB. General Data. Advantages. Applications. Circuit diagram. Standards & 1 Certifications W v Short circuit PCB transformer General Data Rated input 230 Vac Rated output 6-2 x 24 Vac Rated power 0.35-3.2 VA Insulation class B Maximum ambient temperature 70 C Efficiency up to 58 % Degree of protection

More information

SL30-ISO PROFILE SYSTEM

SL30-ISO PROFILE SYSTEM AESTHETICS AND sustainability SL30-ISO PROFILE SYSTEM TECHNICAL DOCuMENTATION WWW.MHB.NL SL30-ISO PROFILE SYSTEM 1. SL30-ISO and SL30-ISO-PLUS Sustainability is getting worldwide more and more the attention

More information

Impact-Resistant Windows and Sliding Glass Doors

Impact-Resistant Windows and Sliding Glass Doors Impact-Resistant Windows and Sliding Glass Doors Make Your Home A SafeHarbor. SafeHarbor Impact-Resistant Windows and Sliding Glass Doors are designed to look like traditional windows and doors, but they

More information

This sample quote was created using the JobFLEX Mobile App Learn More at www.job-flex.com

This sample quote was created using the JobFLEX Mobile App Learn More at www.job-flex.com The Best Products The Best Price The Best Service...We Guarantee It! Prepared For: ABC Company 125 Maple St Rockford, MI 49341 Phone: 555.223.1245 Fax: 555.555.1234 Billing Address Phone: 566.563.5866

More information

Fire Resistant Systems

Fire Resistant Systems Fire Resistant Systems A R C H I T E C T U R A L A L U M I N I U M G L A Z I N G S Y S T E M S Fire Resistant Systems Introduction Kawneer are pleased to introduce two new comprehensive Fire Resistant

More information

WITH LOW EMISSIVITY GLASS

WITH LOW EMISSIVITY GLASS WITH LOW EMISSIVITY GLASS Quebec Version 1.1 tel. : 1 800 463-2810 and fax : 418 687-0804 Version 1.1 tel. : 1 800 463-2810 and fax : 418 687-0804 VA TRANSMITTANCE GROUP 1 / LOW-E POSITION 2 (Lower heat

More information

WATERPROOF PHOTOVOLTAIC SYSTEM

WATERPROOF PHOTOVOLTAIC SYSTEM WATERPROOF PHOTOVOLTAIC SYSTEM Nola, the biggest BIPV plant in the world. 25 MWp 9 KWp 7 KWp 580 KWp 110 KWp 20 KWp 430 KWp Synthetic layer - 50 KWp Synthetic layer - 30 KWp Synthetic layer -9 KWp STOPPING

More information

Standex-Meder Electronics. Custom Engineered Solutions for Tomorrow

Standex-Meder Electronics. Custom Engineered Solutions for Tomorrow Standex-Meder Electronics Custom Engineered Solutions for Tomorrow Latching & Form B Reed Relays & Sensors Product Training Copyright 2013 Standex-Meder Electronics. All rights reserved. Introduction Purpose

More information

Stereolithography Material Properties

Stereolithography Material Properties Details Stereolithography Standard lead time: Standard accuracy: Maximum part dimensions: From 2 working days, depending on the size of the parts and the number of components. Standard stereolithography

More information

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F400-120. advantages.

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F400-120. advantages. Défumair XR smoke-extraction fan extraction casing for kitchen at F400-120 Personalisation : - Phonic insulation version by insulated double-skin panels through 25 mm glass wool, class M1. advantages Originally

More information

Solar control right for you!

Solar control right for you! Solar control right for you! Landesbank Baden-Württemberg, Stuttgart SGG COOL-LITE ST 0 SGG COOL-LITE ST Solar control right for you! D e s c r i p t i o n SGG COOL-LITE ST is a solar control glass manufactured

More information

The answer. Cost-Benefit Ratio of different construction depths. Comparison of U f -values. profine GmbH Kömmerling Kunststoffe

The answer. Cost-Benefit Ratio of different construction depths. Comparison of U f -values. profine GmbH Kömmerling Kunststoffe Order No. 2 02 130270-0310.KA profine GmbH Kömmerling Kunststoffe Postfach 2165 66929 Pirmasens Germany Tel. +49 6331 56-0 Fax +49 6331 56-2475 E-mail: info@koemmerling.de Internet: www.koemmerling.de

More information

Prefabricated building PVC vertical sliding window

Prefabricated building PVC vertical sliding window Prefabricated building PVC vertical sliding window SLOVENSKO ITALIA ESPAÑA ITALIA The company, we have the pleasure to introduce in this brochure, is an important and dynamic industrial company located

More information

Security steel door dw 52-1 Teckentrup DF WK 2 optionally with glazing/ventilation grille

Security steel door dw 52-1 Teckentrup DF WK 2 optionally with glazing/ventilation grille Security steel door dw 52-1 Teckentrup DF WK 2 optionally with glazing/ventilation grille Text example Compile and tender according to requirements. Please refer to technical data below for respective

More information

PRODUCT INFORMATION : ADHESIVES DELIVERING THE FUTURE OF COMPOSITE SOLUTIONS ADHESIVES. contact@gurit.com www.gurit.com

PRODUCT INFORMATION : ADHESIVES DELIVERING THE FUTURE OF COMPOSITE SOLUTIONS ADHESIVES. contact@gurit.com www.gurit.com PRODUCT INFORMATION : ADHESIVES DELIVERING THE FUTURE OF COMPOSITE SOLUTIONS ADHESIVES contact@gurit.com Gurit is a technical leader in the formulation of advanced epoxy resins, and offers a range of two

More information

ENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available.

ENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available. APR 1200 Acoustic Partition Roll CI/Sfb Ref: APR002 Glass mineral wool roll designed to provide high levels of sound insulation in walls and floors to meet Part E (England & Wales) and Section 5 (Scotland)

More information

Master Panel 1000 R5 Roof

Master Panel 1000 R5 Roof Master Panel 1000 R5 Roof Product Description The important feature of the roof elements are the easy installation procedure. The element fix exactly and pushed together without much force. Roof coverage

More information

Confort 160. Sliding Systems. Sapa Building System

Confort 160. Sliding Systems. Sapa Building System Confort 160 Sliding Systems Sapa Building System Confort 160 is a high performance thermally insulated sliding window system, with a user-friendly slide action. The system, which has an attractive aesthetic

More information

ift-product Passport Curtain Walling according to EN 13830 : 2003

ift-product Passport Curtain Walling according to EN 13830 : 2003 ift-product Passport Curtain Walling according to EN 13830 : 2003 100 27203/1-0.6e Valid until June 2015 Client is the system supplier Product family Variants Frame material Basis SCHÜCO International

More information

PYROSWISS VETROFLAM CONTRAFLAM

PYROSWISS VETROFLAM CONTRAFLAM Fire-resistant glass solutions SYSTEMS Description VETROTECH SAINT-GOBAIN specialises in the manufacture of high performance fire-resistant glass products; from single panes of modified toughened glass

More information

Multi-Foil reflective insulation SPACE SAVING U-VALUE AS LOW AS 0.16W/m 2 K LIGHTWEIGHT EASY TO FIX

Multi-Foil reflective insulation SPACE SAVING U-VALUE AS LOW AS 0.16W/m 2 K LIGHTWEIGHT EASY TO FIX Multi-Foil reflective insulation SPACE SAVING U-VALUE AS LOW AS 0.16W/m 2 K LIGHTWEIGHT EASY TO FIX TECHNICAL CHARACTERISTICS Multi-Foil Reflective Insulation Xfoil Range of insulation is designed to achieve

More information

Design qualification and type approval of PV modules acc. to IEC 61215:2005 / IEC 61646:2008

Design qualification and type approval of PV modules acc. to IEC 61215:2005 / IEC 61646:2008 Design qualification and type approval of PV modules acc. to IEC 61215:2005 / IEC 61646:2008 TÜV Rheinland Immissionsschutz und Energiesysteme GmbH Renewable Energies 2009-01-22 January 2009 Design qualification

More information

Asset Data Dictionary Definition Document Continuous Flight Auger Piles (CFA) Uniclass Classification

Asset Data Dictionary Definition Document Continuous Flight Auger Piles (CFA) Uniclass Classification Asset Data Dictionary Definition Document Continuous Flight Auger Piles (CFA) Uniclass Classification Contents Introduction... 3 Asset Details... 3 Description... 3 Asset Tagging... 3 Attributes... 4 Data

More information

Definition of classes and info material to manufacturers related to EN ISO 9806

Definition of classes and info material to manufacturers related to EN ISO 9806 SP Sveriges Tekniska Forskningsinstitut Definition of classes and info material to manufacturers related to EN ISO 9806 SP Sveriges Tekniska Forskningsinstitut Classmate: Definition of classes and drafting

More information

Polymeric membrane for roof waterproofing

Polymeric membrane for roof waterproofing Product Data Sheet Edition 09.2008 Revision no: 0 Identification no: 01 09 01 02 200 0 120000 Sarnafil TS 77-12 Polymeric membrane for roof waterproofing Construction Product Description Uses Characteristics

More information

ICQ Series - square centrifugal

ICQ Series - square centrifugal product ICQ Square Centrifugal (TEFC) dimensions mm 280-710 poles & duty 4-8 / up to 4,500 L/s application High performance centrifugal fans for medium to high pressure ducted systems. ICQ Series The ICQ

More information

Conservatory Roof Structural Information Guide

Conservatory Roof Structural Information Guide Conservatory Roof Structural Information Guide Effective from ugust 8 Useful Information This guide displays data on the permissible roof member spans and for different roof loadings; it should be used

More information

Upstand Rooflight Natural Light Translucent Upstand Systems

Upstand Rooflight Natural Light Translucent Upstand Systems Insulated Panels CI/SfB (4-) Rh2 October 2008 ROOFLIGHT SYSTEM Upstand Rooflight Natural Light Translucent Upstand Systems Upstand Rooflight Pre-assembled Rooflight System Introduction The Upstand Rooflight

More information

systemair Smoke Extract Fans Keep Your Cool: Smoke Extraction with Systemair

systemair Smoke Extract Fans Keep Your Cool: Smoke Extraction with Systemair Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans Smoke Extract Fans Keep Your Cool: Smoke Extraction with Systemair systemair Disclose the secret

More information

AND MEMBRANES ROOFING UNDERLAYS. www.fakro.com

AND MEMBRANES ROOFING UNDERLAYS. www.fakro.com AND MEMBRANES 010 ROOFING UNDERLAYS 1 HO DOES YOUR ROOF BREATHe? MEMBRANES THE WAY to A WARM AND DRY ROOF HO HO HO HO HO HO WATERTIGHTNESS The FAKRO Company offers a wide range of membranes and underlays

More information

Athena is the name given to our assortment of electronic tapes. products of the very highest quality. These tapes both conduct and

Athena is the name given to our assortment of electronic tapes. products of the very highest quality. These tapes both conduct and Electric Athena. Athena is the name given to our assortment of electronic tapes products of the very highest quality. These tapes both conduct and insulate against electricity, in addition to warmth and

More information