CRITICAL CARE CPAP Systems

Size: px
Start display at page:

Download "CRITICAL CARE CPAP Systems"

Transcription

1 CRITICAL CARE CPAP Systems Continuous Positive Airway Pressure

2 Contents Face Masks & Headgear 02 Clariti PEEP Valves 03 Bi-Level Full Face Mask & Headgear 04 V2 Face Mask & Headgear 05 CPAP Systems 06 NIV Systems 10 CPAP Components 11 MAXBlend Flow Generator 12 MaxVenturi Flow Generator 13

3 CPAP Systems Continuous Positive Airway Pressure Continuous Positive Airway Pressure (CPAP) is used to administer fresh gas pressure to the spontaneously breathing patient. By opening more alveolar spaces, CPAP increases the number of functional airways, thereby reducing total resistance.this has been demonstrated in many chronic or acute situations, whether in the post-operative period or in home ventilation. CPAP Benefits: l Increases Functional Residual Capacity (FRC) l Reduces the patient s Work of Breathing (WB) l Maximises alveolar ventilation l Maximises blood oxygenation and reduces carbon dioxide retention l Mobilises respiratory secretions l Improves lung compliance l Shortens stay in intensive care The success of CPAP therapy is highly influenced by patient compliance and the level of comfort provided by the CPAP mask and headgear. We have developed a diverse range of CPAP products and accessories to help ensure total comfort for your patient. 01

4 Face Masks & Headgear ur CPAP face masks are double-ported with unidirectional valves to eliminate rebreathing and are fitted with an anti-asphyxia valve. Masks are also equipped with a pressure monitoring port to enable proximal readings. The clear crown ensures easy visibility and low dead space while the anatomically shaped, large volume, inflatable cuff is designed to provide an effective, low pressure seal. Masks are available in 3 sizes; small, large and large deep to fit a wide range of patient profiles thereby ensuring a comfortable, secure seal. ur deluxe headgear is made from a soft, breathable fabric which is designed to remove moisture from the patient s skin thereby reducing the risk of skin erosion. Soft Velcro fastenings allow for easy fitting and adjustment. Headgear designs are also available in latex-free rubber. Key Features: l Double-ported with unidirectional valves Ensures clear separation of inspiratory and expiratory gas l Anti-asphyxia valve Provides air entrainment to mask if gas supply is interrupted or gas delivery fails l Pressure monitoring port Provides real time measurement of airway pressure l Clear crown Allows visualization of breathing patterns and presence of foreign matter (e.g. Vomitus) l Low mechanical dead space Minimises rebreathing of alveolar C 2 l Anatomically shaped, large volume, inflatable cushion ptimises patient comfort, position of mask and provides an airtight seal l 22mmM inspiratory port Allows direct connectivity to standard 22mm connectors (no need for intermediate adapter) l Available in 3 sizes ptions to suit all patients indicated for high flow CPAP therapy l Soft breathable headgear ptimises patient comfort and mask tolerance Product Information: Box Qty AMFM8881 CPAP face mask, double-ported, small 20 AMFM8882 CPAP face mask, double-ported, large 20 AMFM8883 CPAP face mask, double-ported, large deep 20 AMHS8151 Basic head strap in latex-free rubber 20 AMHS8152 UltraSeal CPAP headgear in latex-free rubber 20 AMHS8154 UltraSeal CPAP headgear in Breathoprene textile 20 AMCP1422/5/1 Pressure monitoring line, length 2.1m 20 AMCA1422/2 xygen tubing, length 2.1m (non-coloured) 20 02

5 Clariti PEEP Valves Positive End ory Pressure (PEEP) is used to maintain pressure on the lower airways at the end of the breathing cycle which prevents the alveoli from collapsing during expiration. Clariti s are fixed valves made from a transparent material which enables monitoring of the patient s respiratory rate and blockage assessment while a highly fluorescent valve facilitates observation of valve functionality. Key Features: l Transparent casing enables monitoring of patient s respiratory rate and blockage assessment l Fluorescent valve facilitates observation of valve functionality l Available in 7 sizes and colour coded l Available as part of a CPAP kit including face mask, headgear and circuit The Clariti range includes seven s ranging from 2.5 to 20cmH 2 which are colour-coded for ease of identification. All our valves are 100% leak-free guaranteed. Product Information: Box Qty Colour AMPV cmH 2 10 AMPV cmH 2 10 AMPV cmH 2 10 AMPV cmH 2 10 AMPV cmH 2 10 AMPV9015 Safety valve 15.0cmH 2 10 AMPV9020 Safety valve 20.0cmH

6 Bi-Level Full Face Mask & Headgear ur Bi-Level face mask adjusts perfectly to the patient s face preventing air leakage and the headgear is made from a soft, breathable fabric which encapsulates the entire head without covering the ears. The headgear has also been designed in such a way that it can be easily fitted by one person while emergency release straps allow for quick and easy removal. Accessories Face masks are also supplied with a unique nasal gastric tube adapter which provides a leak-free seal around the nasal gastric tube. Additional ports provide for supplemental oxygen, EtC 2 measurement and/or pressure monitoring. A bulb pump allows for convenient inflation/deflation of the mask when fitting. Key Features: l Special contour adaptation of cushion provides secure seal and minimises skin erosion l Special connector with ports for 2, EtC 2 and pressure monitoring l Connector design permits use of nasogastric probe, even while patient is being ventilated l Soft breathable headgear l Low dead space l Available in 5 sizes Customised face mask, headgear and tubing kits are available upon request. Product Information: Box Qty KFM001M Full face mask with headgear, large 50 KFM002M Full face mask with headgear, medium 50 KFM003M Full face mask with headgear, small 50 KFM004M Full face mask with headgear, extra small 50 KFM001L Full face mask with headgear, extra large 50 AMNM Nasal mask with headgear, small 50 AMNM Nasal mask with headgear, medium 50 AMNM Nasal mask with headgear, large 50 KEV02597 C 2 exhalational valve 10 AMCA1402/6 22mmØ, 1.8m smoothbore tubing PU 20 04

7 V2 Face Mask & Headgear This mask with its soft face piece and lightweight design offers comfort, a wide range of vision and freedom of movement. A patented seal design with moulded ridges which conform to the contours of the face ensures a comfortable, secure seal. Headgear with easy release clips and adjustable straps make fitting this mask quick and simple. The mask is supplied with a swivel elbow connector, vented or non-vented. Single use and reusable options are also available. Key Features: l Soft medical grade TPE l ne piece mould design l Patented seal design allows mask to conform to facial contours l Deep sealing flange in nose bridge area helps create secure seal l Chin Cup provides easy positioning of mask, stability and comfort l Swivel elbow connector; non-vented or vented with anti-asphyxia valve l Available in 5 sizes, single use or reusable Product Information: Box Qty HRFM V2 face mask non-vented, large with headgear 1 HRFM V2 face mask non-vented, medium with headgear 1 HRFM V2 face mask non-vented, small with headgear 1 HRFM V2 face mask non-vented, extra small with headgear 1 HRFM V2 face mask non-vented, petite with headgear 1 HRFM V2 face mask vented, AAV, large with headgear 1 HRFM V2 face mask vented, AAV, medium with headgear 1 HRFM V2 face mask vented, AAV, small with headgear 1 HRFM V2 face mask vented, AAV, extra small with headgear 1 HRFM V2 face mask vented, AAV, petite with headgear 1 HRFM V2 face mask, reusable, vented, AAV, large with headgear 1 HRFM V2 face mask reusable, vented, AAV, medium with headgear 1 HRFM V2 face mask reusable, vented, AAV, small with headgear 1 HRFM V2 face mask reusable, vented, AAV, extra small with headgear 1 HRFM V2 face mask reusable, vented, AAV, petite with headgear 1 05

8 413 Phar a Systems, Sweden CE VENT BA FREE xpirat From 0120 Fro 413 From CPAP Systems ur range of CPAP systems includes configurations for face mask CPAP, tracheal tube CPAP and dual CPAP. The following is only a representation of our offering in CPAP systems. Should you wish to design a system to meet your particular requirements please refer to the CPAP components section or contact your local representative. Face Mask CPAP System AMCPUK01042 Face mask CPAP system, non-heated, length 2.0m with large, double-ported CPAP face mask, Breathoprene UltraSeal headgear, 5cmH 2 PEEP valve and breathing filter. 2m Mask Size Small 5cmH 2 AMCPUK mm port Face mask CPAP system, heated for 850 series heater humidifier, length 1.6m, with large double-ported CPAP face mask, UltraSeal head strap, 5cmH 2 with 1.2m humidification limb, safety valve, oxygen analyser T-piece and auto-fill humidification chamber. 7.6mm port Auto fill humidification chamber Heated limb 1.6m 1.2m 5cmH 2 For 2 analyser 20cmH 2 Safety valve 22M(15F) AMCPSI mm port Face mask CPAP system, heated for 730 series heater humidifier, length 1.6m with small double-ported CPAP face mask, Breathoprene UltraSeal headgear, manometer line with 0.2µm hydrophobic filter with 0.8m humidification limb, breathing filter and auto-fill humidification chamber. Auto fill humidification chamber Heated limb 1.6m 0.8m FREE - VENT BA Phar a Systems, Sweden CE

9 Fro 0120 From VENT BA FREE 0120 From Tracheal Tube CPAP System Tracheal tube CPAP systems facilitate an effective transition from the ventilator to face mask CPAP, without having to remove the tracheal tube at an early stage. AMCP02000 Tracheal tube CPAP system, non-heated, length 1.6m with flow-by limb, suction-ported tracheal T-piece, 5cmH 2 PEEP valve and safety valve. 0.4m 7.6mm port 1.6m 15cm H 2 Safety valve 5cm H 2 AMCPUK01151 Tracheal tube CPAP system, heated for 850 series heater humidifier, length 1.6m with flow-by limb, 5.0cmH 2, plain tracheal T-piece, 0.8m humidification limb, breathing filter and auto-fill humidification chamber. 5.0cmH 2 7.6mm port 0.4m 1.6m 0.8m Auto fill Humidifcation chamber AMCPUK mm port Tracheal tube CPAP system, heated for 730 series heater humidifier, length 1.6m with flow-by limb, 5.0cmH 2, suction-ported tracheal T-piece and 0.8m humidification limb. 5cmH 2 0.4m 1.6m 0.8m 07

10 xpirat Fro Fro xpirat Fro VENT BA FREE From From Dual CPAP System For face mask or intubated patients Dual CPAP systems enable change over from a tracheal tube set up to a face mask set up without the requirement to hold stock of separate assembled systems. Dual systems come assembled in the tracheal tube configuration. To change the configuration to a face mask set up please amend as follows: l l l l l l Replace sealing cap on patient T-piece Assemble to bottom port of CPAP mask Assemble adapter to top port of CPAP mask and connect inspiratory tubing to adapter Attach manometer line to spigot on CPAP mask Connect assembled system to patient, using headgear provided Confirm pressure measurement and commence therapy AMCP03000 Dual CPAP system for face mask or intubated patients, non-heated, length 2.0m with flow-by limb, suction-ported tracheal T-piece, 5cmH 2, large double-ported CPAP face mask, Breathoprene UltraSeal headgear and safety valve. 5.0cmH 2 0.4m Mask Size Large 2.0m 15.0cmH 2 safety valve AMCPUK01208 Dual CPAP system for face mask or intubated patients, heated for 850 series heater humidifier, length 1.6m with flow-by limb, tracheal T-piece, 5cmH 2, large double-ported CPAP face mask, Breathoprene UltraSeal headgear and safety valve. 5.0cmH 2 Mask Size Large 7.6mm port 0.4m 1.6m 0.8m Auto fill Humidifcation chamber AMCP m 7.6m port 1.6m Dual CPAP system for face mask or intubated patients, heated for 730 series heater humidifier, length 1.6m with flow-by limb, suction-ported tracheal T-piece, 5cmH 2, large double-ported CPAP face mask, Breathoprene UltraSeal headgear and safety valve. 5.0cmH 2 0.8m Mask Size Large 15.0cmH 2 Safety valve 08

11 0120 From 0120 From CPAP Kits ur CPAP face masks, headgear and s are available as kits ready for use in a variety of combinations and designed for use with our CPAP breathing systems. CPAP kits offer convenience, choice and reduced packaging. Below are some of our more popular combinations. AMCPUK01056 Large double-ported CPAP face mask with UltraSeal headgear and 5.0cmH 2. AMCPUK8882/004 Large double-ported CPAP face mask with Breathoprene UltraSeal headgear and 5.0cmH 2. 22M 5cmH 2 AMCPUK8883/006 Large deep double-ported CPAP face mask with Breathoprene UltraSeal headgear and 7.5cmH 2. 22M 7.5cmH 2 09

12 NIV Systems ur range of NIV systems includes both nasal and oronasal masks suitable for a range of Bi-Level and NIPPV machines. Masks are available with or without C 2 venting. All mask configurations are available in bespoke kits with ventilator tubing. The following is only a representation of our offering in NIV systems. Should you wish to design a system to meet your particular requirements please contact your local representative. AMVC1792/092 Ventilator circuit, single limb, adult, non-heated, length 1.8m in smooth bore PE tubing with bacterial viral breathing filter. AMVC1792/016 Ventilator circuit, adult, single limb, non-heated, length 1.8m in smooth bore tubing with exhalation valve with double swivel plain patient elbow with bacterial viral breathing filter with supplemental oxygen tubing. AMVC1792/004 Ventilator circuit, adult, single limb, heated for use with 850 series heater humidifier, length 1.5m in smooth bore tubing with exhalation valve with tubing and 0.2µm hydrophobic gas filter with humidification limb length 0.8m in corrugated tubing with auto-fill humidification chamber with bacterial viral breathing filter. 10

13 CPAP Components A range of CPAP components are available for use with our CPAP face masks, headgear and breathing systems. Components can be assembled to your requirements or purchased separately. Product Information: Box Qty AMFM8881 CPAP face mask, double-ported, small 20 AMFM8882 CPAP face mask, double-ported, large 20 AMFM8883 CPAP face mask, double-ported, large deep 20 AMHS8151 Basic head strap in latex-free rubber 20 AMHS8152 UltraSeal CPAP headgear in latex-free rubber 20 AMHS8154 UltraSeal CPAP headgear in Breathoprene textile 20 AMCP1422/5/1 Pressure monitoring line, length 2.1m 20 AMPV cmH 2 10 AMPV cmH 2 10 AMPV cmH 2 10 AMPV cmH 2 10 AMPV cmH 2 10 AMPV9015 Safety valve 15.0cmH 2 10 AMPV9020 Safety valve 20.0cmH 2 10 AMCA9005/A Mask connector, 30mmM/22mmM 20 AMCA1300 Straight connector, 22mmM/22mmM(15mmF) 50 AMCA1303 Straight connector, 22mmM/22mmF with 7.6mm port 50 AMCA1328 Straight connector, 22mmM/22mmM with 7.6mm port 50 AMCA1450 T-piece, 22mmM/22mmM/22mmM(15mmF) 50 AMCA1452 T-piece, 22mmM/22mmF/22mmM(15mmF) 50 AMCA1453 T-piece, 22mmM/22mmM/22mmM(15mmF) with 7.6mm port 50 AMCA1454 T-piece, 22mmM/22mmF/22mmM(15mmF) with 7.6mm port 50 AMCA1455 T-piece, 22mmM/22mmF/22mmF 50 AMCA1400/1/1 Tubing limb, 0.4m length, 22mmF/22mmF 20 AMCA1400/1/2 Tubing limb, 0.8m length, 22mmF/22mmF 20 AMCA1400/1/3 Tubing limb, 1.2m length, 22mmF/22mmF 20 AMCP1407 Heated tubing limb, length 1.2m, for 730 series heater humidifier 20 AMCP1408 Heated tubing limb, length 1.4m, for 730 series heater humidifier 20 AMCP1409 Heated tubing limb, length 1.6m, for 730 series heater humidifier 20 AMCP1407/001 Heated tubing limb, length 1.2m, for 850 series heater humidifier 20 AMCP1408/001 Heated tubing limb, length 1.4m, for 850 series heater humidifier 20 AMCP1409/001 Heated tubing limb, length 1.6m, for 850 series heater humidifier 20 11

14 MAXBlend TM Flow Generator The MAXBlend TM is designed to provide a continuous air/oxygen gas mixture to paediatric and adult patients. Specifically designed for high flow CPAP, the MAXBlend TM uses leading air/oxygen blending technology in combination with oxygen monitoring technology. It is unique from all other flow generators, as oxygen flow control is separate from air flow control enabling 21% oxygen concentration with any size of at any flow rate. MAXBlend TM with its built-in monitor provides the ability to measure oxygen percentage in a clean and dry environment away from the patient. Key Features: l Three-in-one blender enables precise mixing of medical air and oxygen l Helps eliminate cross-contamination l Provides measurements free from temperature, pressure & humidity l Digital display of oxygen concentration in the range of % at any flow rate up to 120L/min l 18% low to 99% high alarm capabilities (visible and audible) l Connects directly to wall mounted oxygen and air supplies or gas cylinders l Compact and quiet l Highly portable l Simple to use l 24-month warranty Product Information: AMMBCS1 AMMBFG1 AMMBPS AMMBPM1 AMMBPH1 AMMBPH2 AMMBFM1 AMMBFC1 AMMBMA AMMBFA MAXBlend TM CPAP Flow Generator complete system with pole mount, oxygen and medical air high pressure hoses, rotameter flow meter and oxygen fuel cell MAXBlend TM CPAP Flow Generator Stand with pole, stainless steel with locking casters Pole mount for MAXBlend TM CPAP Flow Generator xygen high pressure hose for MAXBlend TM CPAP Flow Generator Medical air high pressure hose for MAXBlend TM CPAP Flow Generator 120L/min rotameter flow meter for MAXBlend TM CPAP Flow Generator Galvanic oxygen fuel cell for MAXBlend TM CPAP Flow Generator Analogue manometer with pole mount 22mmM flow meter adapter, black 12

15 MaxVenturi TM Flow Generator The MaxVenturi TM has been specially designed to interface with high flow humidification systems. It provides users with the ability to mix ambient air and oxygen without the need for piped medical grade air, creating the perfect system for patients requiring high flow therapy. Key Features: l Ability to mix ambient air and oxygen without the need for piped medical air l Independent adjustable 2 % and flow l Long battery life on analyser (approximately 5,000 hours) l All-in-one oxygen/air mixer, Max 2 + analyser and flow meter l 24-month warranty Product Information: MTV211P MaxVenturi TM with oxygen sensor and Hewitt clamp MTV211P MaxVenturi TM with oxygen sensor and basic clamp MTSR115P85 xygen sensor for MaxVenturi TM AMMBPH3 xygen hose for MaxVenturi TM (NIST), length 2.0m 13

16 Armstrong Medical Wattstown Business Park Newbridge Road Coleraine BT52 1BS T +44 (0) F +44 (0) E info@armstrongmedical.net W Creating Support for Life Creating Support for Life All Armstrong Medical products are manufactured to quality systems under IS and EC Directive 93/42/EEC. Distributed by: AMCPBR01 Armstrong manufacture a complete range of disposable respiratory products for anaesthesia and critical care applications. For supply of these products or any product within the Armstrong range, please contact your local representative.

GUIDELINES FOR THE MANAGEMENT OF OXYGEN THERAPY

GUIDELINES FOR THE MANAGEMENT OF OXYGEN THERAPY SOUTH DURHAM HEALTH CARE NHS TRUST GUIDELINES FOR THE MANAGEMENT OF OXYGEN THERAPY AIM To supplement oxygen intake using the appropriate equipment in order to correct hypoxia and relieve breathlessness.

More information

Nasal-Aire II Critical Care Single-use CPAP interface by InnoMed The comfortable, economical solution to non-invasive ventilation!

Nasal-Aire II Critical Care Single-use CPAP interface by InnoMed The comfortable, economical solution to non-invasive ventilation! CPAP Nasal-Aire II Critical Care Single-use CPAP interface by InnoMed The comfortable, economical solution to non-invasive ventilation! Advantages:. Can be worn for any duration without discomfort-no uncomfortable

More information

Mirage FX NASAL MASK. User Guide

Mirage FX NASAL MASK. User Guide Mirage FX NASAL MASK User Guide Mirage FX NASAL MASK Fitting// 1 2 3 4 5 6 Mirage FX i Removal// 1 2 Disassembly// 1 2 3 ii Reassembly// 1 2 3 4 iii Mirage FX A 2 3 1 4 7 6 5 B iv Mask components// Item/

More information

Shiley Product Guide. Shiley TM XLT Extended-Length Tracheostomy Tubes. Shiley TM Disposable Inner Cannula

Shiley Product Guide. Shiley TM XLT Extended-Length Tracheostomy Tubes. Shiley TM Disposable Inner Cannula Shiley Product Guide Shiley TM XLT Extended-Length Shiley TM Disposable Inner Cannula Shiley TM Percutaneous Disposable Inner Cannula Shiley TM Accessories for Disposable Inner Cannula Tubes Shiley TM

More information

Do not use soaps with added scents. We recommend plain Ivory liquid soap or baby shampoo. Rinse well and allow to air dry out of direct sunlight.

Do not use soaps with added scents. We recommend plain Ivory liquid soap or baby shampoo. Rinse well and allow to air dry out of direct sunlight. ResMed CPAP Mask FAQ When and how should I clean my mask? Daily Wash the mask system with warm, soapy water. Do not use soaps with added scents. We recommend plain Ivory liquid soap or baby shampoo. Rinse

More information

Understanding Anesthetic Delivery Systems Dean Knoll, CVT, VTS (Anes.) Anesthesia Technician Supervisor University of Wisconsin Madison, WI May 2003

Understanding Anesthetic Delivery Systems Dean Knoll, CVT, VTS (Anes.) Anesthesia Technician Supervisor University of Wisconsin Madison, WI May 2003 Understanding Anesthetic Delivery Systems Dean Knoll, CVT, VTS (Anes.) Anesthesia Technician Supervisor University of Wisconsin Madison, WI May 2003 Knowing the functions of the anesthetic delivery system

More information

National Hospital for Neurology and Neurosurgery. Continuous positive airway pressure (CPAP) Sleep Respiratory Unit

National Hospital for Neurology and Neurosurgery. Continuous positive airway pressure (CPAP) Sleep Respiratory Unit National Hospital for Neurology and Neurosurgery Continuous positive airway pressure (CPAP) Sleep Respiratory Unit If you would like this document in another language or format or if you require the services

More information

VENTILATION SERVO-s EASY AND RELIABLE PATIENT CARE

VENTILATION SERVO-s EASY AND RELIABLE PATIENT CARE VENTILATION SERVO-s EASY AND RELIABLE PATIENT CARE Critical Care SERVO-s 3 SERVO-s SIMPLY MAKES SENSE MAQUET THE GOLD STANDARD Leading the way: MAQUET is a premier international provider of medical products

More information

Critical Care Therapy and Respiratory Care Section

Critical Care Therapy and Respiratory Care Section Category: Section: Title: Critical Care Therapy and Respiratory Care Section Policy #: 03 Revised: 5/02 1.0 DESCRIPTION Clinical Ventilator Management Invasive and Noninvasive Positive Pressure Ventilation

More information

Ventilators/Transport*

Ventilators/Transport* Ventilators/Transport* pneuton A (Pneumatic Transport Ventilator) pneuton (pronounced new ton ); a small, lightweight transport ventilator designed for use on patients from pediatric to adult in size.

More information

Trilogy accessory guide

Trilogy accessory guide Trilogy accessory guide 2 Trilogy accessory guide Light, versatile, and easy to use, Trilogy portable life-support ventilators are designed for use in the home and alternative care sites and provide noninvasive

More information

Mirage FX. User Guide. English NASAL MASK

Mirage FX. User Guide. English NASAL MASK Mirage FX NASAL MASK User Guide English Did you know? Replacing your mask and supplies is one of the most important steps in maintaining effective therapy. Replace when... The cushion is no longer clear

More information

ResMed Mask Materials January 2009

ResMed Mask Materials January 2009 ResMed Mask s January 2009 PRODUCT BULLETIN Bulletin Number: 590 Month/Year: January 2009 Distribution: Global Date of implementation: Immediately Replaces Product Bulletin #578 Following are details of

More information

Artificial Ventilation Theory into practice

Artificial Ventilation Theory into practice Artificial Ventilation Theory into practice Keith Simpson BVSc MRCVS MIET(Electronics) www.vetronic.co.uk ksimpson@vetronic.co.uk June 13 th 2014 Today we will discuss the administration of IPPV to anaesthetised

More information

The centrepiece of a complete anaesthesia workstation

The centrepiece of a complete anaesthesia workstation The centrepiece of a complete anaesthesia workstation IntelliSave AX700 anaesthesia machine A slim design with rich functionality To develop the first Philips-branded anaesthesia machine, we listened to

More information

ResMed Mask Materials December 2010-12-16

ResMed Mask Materials December 2010-12-16 ResMed Mask s December 2010-12-16 PRODUCT BULLETIN Bulletin Number: #679 Month/Year: January 2011 Distribution: Patient Interface Product Managers World-Wide Date of implementation: Immediately Replaces

More information

MEDICAL SYSTEMS. Monnal T60. Touch and Breathe. www.airliquidemedicalsystems.com

MEDICAL SYSTEMS. Monnal T60. Touch and Breathe. www.airliquidemedicalsystems.com MEDICAL SYSTEMS Monnal T60 Touch and Breathe www.airliquidemedicalsystems.com Close to the emergency Monnal T60 has been designed for mobile medical intervention in all intensive care environments, both

More information

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pumps Eurovacuum Company is offering its various products to meet industrial vacuum

More information

PROCEDURE FOR USING A NASAL CANNULA

PROCEDURE FOR USING A NASAL CANNULA PROCEDURE FOR USING A NASAL CANNULA A nasal cannula is used to deliver a low to moderate concentration of oxygen. It can be used as long as nasal passages are open. A deviated septum, swelling of the nasal

More information

THERAPY SYSTEMS Therapy Systems

THERAPY SYSTEMS Therapy Systems Therapy Systems CPAP Therapy REMstar Plus M Series with C-Flex Offers optional integrated humidification, optional Encore Pro SmartCard capability for basic compliance reporting, therapy meter display,

More information

High pressure reactors Where are your limits?

High pressure reactors Where are your limits? Laboratory equipment High pressure reactors Where are your limits? Modern high pressure reactors need to be technically safe, reliable, economical in use and simple to operate. With Berghof quality and

More information

1. CPAP: delivers continuous flow of air at a constant pressure.

1. CPAP: delivers continuous flow of air at a constant pressure. What does CPAP stand for? CPAP stands for Continuous Positive Airway Pressure. What does CPAP therapy do? CPAP therapy provides a constant airflow which holds the airway open so that uninterrupted breathing

More information

Airway Pressure Release Ventilation

Airway Pressure Release Ventilation Page: 1 Policy #: 25.01.153 Issued: 4-1-2006 Reviewed/ Revised: Section: 10-11-2006 Respiratory Care Airway Pressure Release Ventilation Description/Definition Airway Pressure Release Ventilation (APRV)

More information

POLICIES & PROCEDURES. ID Number: 1115

POLICIES & PROCEDURES. ID Number: 1115 POLICIES & PROCEDURES Title: OXYGEN ADMINISTRATION ID Number: 1115 Authorization [X] SHR Nursing Practice Committee Source: Nursing, Respiratory Therapy, Physiotherapy Date Revised: March 2015 Date of

More information

The Mercury Medical s Flow-Safe CPAP System

The Mercury Medical s Flow-Safe CPAP System 201 3 2014 INSERT COMPANY LOGO HERE 2014 2013 North North American American Airway SSL Management Certificate Devices Product Product Leadership Leadership Award Award Frost & Sullivan 1 We Accelerate

More information

For every breath he takes. Trilogy200 ventilator s added sensitivity lets you breathe easier knowing your patients are where they belong home.

For every breath he takes. Trilogy200 ventilator s added sensitivity lets you breathe easier knowing your patients are where they belong home. For every breath he takes Trilogy200 ventilator s added sensitivity lets you breathe easier knowing your patients are where they belong home. Sensitive to your patients needs Trilogy200, a portable life-support

More information

GRADE 11F: Biology 3. UNIT 11FB.3 9 hours. Human gas exchange system and health. Resources. About this unit. Previous learning.

GRADE 11F: Biology 3. UNIT 11FB.3 9 hours. Human gas exchange system and health. Resources. About this unit. Previous learning. GRADE 11F: Biology 3 Human gas exchange system and health UNIT 11FB.3 9 hours About this unit This unit is the third of six units on biology for Grade 11 foundation. The unit is designed to guide your

More information

Impact Uni-Vent 754 Portable Ventilator

Impact Uni-Vent 754 Portable Ventilator Impact Uni-Vent 754 Portable Ventilator Description - Indications- Contraindications- Side Effects- Special Considerations- The Uni-Vent 754 Portable Ventilator is a portable electronically controlled,

More information

Procedure Code A4215 22 Insulin pen needles A4230 Infusion set for external insulin pump, non needle cannula type A4231 Infusion set for external

Procedure Code A4215 22 Insulin pen needles A4230 Infusion set for external insulin pump, non needle cannula type A4231 Infusion set for external A4215 22 Insulin pen needles A4230 Infusion set for external insulin pump, non needle cannula type A4231 Infusion set for external insulin pump, needle type A4232 Syringe with needle for external insulin

More information

6 Crankcase Ventilation

6 Crankcase Ventilation 6 Crankcase Ventilation Introduction... 6-3 Crankcase Ventilation Manager (CVM)... 6-5 Introduction... 6-6 CVM280B..................................... 6-7 CVM280T... 6-10 CVM424B....................................

More information

first base 3 BUMP PROTECTION

first base 3 BUMP PROTECTION first base 3 BUMP PROTECTION First Base A REVOLUTION IN BUMP PROTECTION. In 1997, following extensive customer research, industry pioneers Scott Safety introduced the original baseball style bump protection

More information

PROCEDURE FOR USING A NASAL CANNULA

PROCEDURE FOR USING A NASAL CANNULA FOR USING A NASAL CANNULA A nasal cannula is used to deliver a low to moderate concentration of oxygen. It can be used as long as nasal passages are open. A deviated septum, swelling of the nasal passages,

More information

2000 Respironics, Inc. All rights reserved.

2000 Respironics, Inc. All rights reserved. Clinical Manual TM Clinical Manual BiPAP systems are the subject of one or more of U.S. Patents #5148802, #5239995, #5313937, #5433193, Canadian Patent #2, 024, 477, European Patent #EP0425092, German

More information

Description TERMINAL UNIT AFNOR NF S 90-116

Description TERMINAL UNIT AFNOR NF S 90-116 PF-01US-00O2 PF-02AU-00O2 PL-23A0-10O2 TERMINAL UNIT AFNOR NF S 90-116 UNI base block with welding nut for Oxygen Outlet AFNOR NF S 90-116 for Oxygen Coloured ring for oxygen Complete terminal units AFNOR

More information

Mask Information Guide

Mask Information Guide Mask Information Guide Welcome to your handy guide to ResMed masks Here you ll find mask selection information, fitting guides, product codes, product features and benefits for the full range of ResMed

More information

Datex Ohmeda. Centiva /5. Service Manual Software rev. 2.1n

Datex Ohmeda. Centiva /5. Service Manual Software rev. 2.1n Datex Ohmeda Centiva /5 Service Manual Software rev. 2.1n Table of Contents 1 Introduction 2 Theory of Operation 3 Post-Service Checkout 4 Tests and Calibrations 1.1 What this manual includes 1-2 1.1.1

More information

Active Pressure Relieving Systems

Active Pressure Relieving Systems Active Pressure Relieving Systems Phase III The easy access, simple to use CPR facility tag allows rapid deflation of the mattress within 10 seconds. The Phase III mattress incorporates high frequency

More information

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant). Fittings for CO 2 Pipe Threads Pipe thread references quoted in this catalogue conform with the requirements specified in the latest issue and amendments of the following ISO Standards: ISO 7-1 (BS21)

More information

Workshop Face Masks Standards

Workshop Face Masks Standards Workshop Face Masks Standards European Standard 1. EN 14683 (Surgical masks - Requirements and test methods) Introduction: The transmission of infective agents during surgical procedures in operating theatres

More information

INTRODUCING RESMED S. Home NIV Solutions. S9 VPAP ST-A with ivaps S9 VPAP ST. Why choose average when you can choose intelligent?

INTRODUCING RESMED S. Home NIV Solutions. S9 VPAP ST-A with ivaps S9 VPAP ST. Why choose average when you can choose intelligent? INTRODUCING RESMED S Home NIV Solutions S9 VPAP ST-A with ivaps S9 VPAP ST Why choose average when you can choose intelligent? Now you can provide intelligent air through ResMed s intelligent Volume-Assured

More information

1.40 Prevention of Nosocomial Pneumonia

1.40 Prevention of Nosocomial Pneumonia 1.40 Purpose Audience Policy Statement: The guideline is designed to reduce the incidence of pneumonia and other acute lower respiratory tract infections. All UTMB healthcare workers and contract healthcare

More information

FREEPHONE 0800 0855617 FREEFAX 0800 0859849

FREEPHONE 0800 0855617 FREEFAX 0800 0859849 178 SPHYGS Dekamet Sphygmomanometer Made in UK and guaranteed accurate to BS EN 1060 1 Lightweight diecast case Shatterproof plastic manometer tube Mercury reservoir isolation valve Comes in 3 attractive

More information

Oxygen & Aerosol Therapy

Oxygen & Aerosol Therapy Oxygen & Table of Contents Unomedical Oxygen Delivery System...3-7 Unomedical Oxygen Delivery System... 3 Low... 4 Nasal Oxygen Cannulas... 4 Oxygen Catheters... 4 Medium... 5 Medium Oxygen Masks... 5

More information

MODULE. POSITIVE AIRWAY PRESSURE (PAP) Titrations

MODULE. POSITIVE AIRWAY PRESSURE (PAP) Titrations MODULE POSITIVE AIRWAY PRESSURE (PAP) Titrations POSITIVE AIRWAY PRESSURE (PAP) TITRATIONS OBJECTIVES At the end of this module the student must be able to: Identify the standards of practice for administering

More information

For over 40 years, the leader in. nitrous oxide. equipment technology.

For over 40 years, the leader in. nitrous oxide. equipment technology. Conscious Sedation Delivery Systems For over 40 years, the leader in nitrous oxide equipment technology. Made in U.S.A. Over 40 years ago Fraser Sweatman pioneered the technology used for safe delivery

More information

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions Lightweight, compact, ergonomic, safe POLARIS FID Portable TOC Analyser for Stack Emissions The Portable FID for Stack Emissions: lightweight, compact, ergonomic, safe POLARIS FID" analyser realized by

More information

TAS ITA. DA1, dual csatlakozásfor thermostat. For control of 2 heaters on 1 thermostat. * * * * * * * * 41.729.220 Thermostat for CH 12/18

TAS ITA. DA1, dual csatlakozásfor thermostat. For control of 2 heaters on 1 thermostat. * * * * * * * * 41.729.220 Thermostat for CH 12/18 ACCESSORIES RT1, RT2, RT3 IT1 DA1 Thermostat for CH 12/18. Digital timer, burning and ventilating. Fault detector GSM. GSM temperature fault detector. THERMOSTATS RT1, room thermostat -10/+40 C with 5

More information

BiPAP autosv Advanced System One USER MANUAL

BiPAP autosv Advanced System One USER MANUAL BiPAP autosv Advanced System One USER MANUAL 2010 Koninklijke Philips Electronics N.V. All rights reserved. Table of Contents Intended Use... 2 Warnings... 2 Cautions... 2 Contraindications... 3 Patient

More information

Oxygenation. Chapter 21. Anatomy and Physiology of Breathing. Anatomy and Physiology of Breathing*

Oxygenation. Chapter 21. Anatomy and Physiology of Breathing. Anatomy and Physiology of Breathing* Oxygenation Chapter 21 Anatomy and Physiology of Breathing Inspiration ~ breathing in Expiration ~ breathing out Ventilation ~ Movement of air in & out of the lungs Respiration ~ exchange of O2 & carbon

More information

MÁQUINAS AGRÍCOLAS JACTO S.A. EDITION

MÁQUINAS AGRÍCOLAS JACTO S.A. EDITION AJ English version EDITION - 06/007 CODE - 9790 Parts catalog MÁQUINAS AGRÍCOLAS JACTO S.A. Rua Dr. Luiz Miranda, 650 7580-000 - Pompéia - SP - Brasil Tel.: +55 4 3405-00 - Fax: +55 4 345 306 E-mail: export@jacto.com.br

More information

ANAESTHESIA AND GENERAL SURGERY PRODUCTS PHOENIX BRAND

ANAESTHESIA AND GENERAL SURGERY PRODUCTS PHOENIX BRAND ANAESTHESIA AND GENERAL SURGERY PRODUCTS PHOENIX BRAND PHOE Apr 11 ENDOBRONCHIAL TUBE, SINGLE USE Original Dr Frank Robertshaw design. D shaped lumina provides maximum cross sectional area, minimising

More information

COUNTERBALANCE VALVES

COUNTERBALANCE VALVES COUNTERBALANCE VALVES Introduction They are modulating valves which allow free flow into the actuator and then block the reverse flow until they feel a pilot pressure inversely proportional to the load

More information

ISO/VDMA Actuators. Engineering GREAT Solutions

ISO/VDMA Actuators. Engineering GREAT Solutions ISO/VDMA Actuators Engineering GREAT Solutions 02 ISO/VDMA Actuators Contents 03 Introduction 04 ISO/VDMA Actuators 06 The ISO/VDMA Range 08 Industrial Options 10 Cleanline Options 12 IVAC innovation to

More information

ACCESSORIES OXYGEN-THERAPY

ACCESSORIES OXYGEN-THERAPY OXYGEN-THERAPY English version 11/ 2010 HUMIDIFIERS The humidifier is used to humidify the oxygen or the medical air delivered to the patient through the respiratory tract. Screwed to the outlet of a flowmeter

More information

Stellar 150 Invasive and noninvasive ventilator

Stellar 150 Invasive and noninvasive ventilator 248369/6 2012-05 Stellar 150 CLINICAL AMER ENG Stellar 150 Invasive and noninvasive ventilator Clinical Guide English Manufacturer: ResMed Germany Inc. Fraunhoferstr. 16 82152 Martinsried Germany Distributed

More information

HOSE AND TUBING CATALOGUE SOLD BY THE ROLL OR IN INCREMENTS OF 1M, STANDARD COIL LENGTH 30 METRES. SIZE (I.D x WALL) CODE SIZE (I.

HOSE AND TUBING CATALOGUE SOLD BY THE ROLL OR IN INCREMENTS OF 1M, STANDARD COIL LENGTH 30 METRES. SIZE (I.D x WALL) CODE SIZE (I. FUEL LINE Temperature: -40 C to +125 C continuous service. Tube: Type C (Nitrile). Black. Oil and petrol resistant. Reinforcement: Single ply of synthetic fibre. Cover: Type C2 (NBR/PVC). Black. Fuel,

More information

GEET Fuel Processor Plans

GEET Fuel Processor Plans GEET Fuel Processor Plans This is a greatly simplified Proof of Concept version of the GEET Fuel Processor that just about anyone can build from parts from a local Hardware store in a weekend for very

More information

Covering the Spectrum

Covering the Spectrum Warming Unit / Model 24500 Setpoint temperature: 41 C Alarms (audible & visible): - Over-temperature primary setpoint = 43 C - Over-temperature secondary setpoint = 46 C Device rating: 110-120 VAC / 220-240

More information

Sensors / Modules / Monitors. Breath Gas Sensing and Monitoring. For life supporting systems in intensive, emergency and ambulant care

Sensors / Modules / Monitors. Breath Gas Sensing and Monitoring. For life supporting systems in intensive, emergency and ambulant care Sensors / Modules / Monitors Breath Gas Sensing and Monitoring For life supporting systems in intensive, emergency and ambulant care Your competent partner for breath gas sensing and monitoring EnviteC

More information

www.respironics.com CPAP System User Manual 1007167 LK 5/12/01

www.respironics.com CPAP System User Manual 1007167 LK 5/12/01 www.respironics.com CPAP System User Manual 1007167 LK 5/12/01 Table of Contents Symbol Key... 2 Intended Use... 3 Specifications... 4 Warnings & Cautions... 5 Unpacking the System... 6 System Features...

More information

Helping to protect you from exposure to hazardous drugs

Helping to protect you from exposure to hazardous drugs Helping to protect you from exposure to hazardous drugs Closed system solution: Texium closed male luer and SmartSite needle-free valve products What you can t see can hurt you The risks are well documented

More information

Powers Controls TH 192 S Single Temperature Room Thermostat

Powers Controls TH 192 S Single Temperature Room Thermostat Technical Instructions Document No. 155-065P25 TH 192-1 Powers Controls TH 192 S Single Temperature Room Thermostat 50 60 70 80 TH0355R1 70 80 POWERS Description The TH 192 S thermostats are proportional

More information

Parts Manual. TWIN 2 & 3 Parts & Accessories F210846R01. Your efficiency is our Challenge!

Parts Manual. TWIN 2 & 3 Parts & Accessories F210846R01. Your efficiency is our Challenge! Parts Manual TWIN 2 & 3 Parts & Accessories F210846R01 Your efficiency is our Challenge! All rights reserved. No part of this manual may be copied and/or published by means of printing, photocopying, microfilm

More information

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered Electrical Temperature Measurement DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered WIKA Data Sheet TE 60.75 Applications Machinery, plant and tank construction

More information

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion

More information

DATA SHEET. Capnography option. www.airliquidemedicalsystems.com. November 2013 V2.2

DATA SHEET. Capnography option. www.airliquidemedicalsystems.com. November 2013 V2.2 November 2013 V2.2 DATA SHEET www.airliquidemedicalsystems.com [1] Monnal T75 (CO 2 )/ Air Liquide Medical Systems APPLICATION AREA OPERATING CONDITIONS Application: Patient categories: Weight: Intensive

More information

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ELECTRICAL SAFETY This appliance is for indoor use only. Always turn off the unit and unplug

More information

Table of contents. Exercise 1 Passive exhalation port 13. Exercise 2 Active exhalation valve 15

Table of contents. Exercise 1 Passive exhalation port 13. Exercise 2 Active exhalation valve 15 Trilogy workshop Table of contents Trilogy Workshop Introduction 4 Trilogy100 circuit options 5 Trilogy200 circuit options 6 Breath types 6 Pressure modes 7 Volume modes 7 Waveforms 7 Sensitivity 7 User

More information

PRODUCT RELEASE CKMTA12 / 24. Copyright 2011 by ARB Corporation Limited

PRODUCT RELEASE CKMTA12 / 24. Copyright 2011 by ARB Corporation Limited PRODUCT RELEASE CKMTA12 / 24 Copyright 2011 by ARB Corporation Limited ARB 4x4 ACCESSORIES 720 SW 34Th Street Tel: (425) 264-1391 Renton, Washington 98057 Fax: (425) 264-1392 USA North and South American

More information

Aliseo Anesthesia system

Aliseo Anesthesia system Aliseo Anesthesia system Cost effective technology in anesthesia Features Ventilator Electrically driven Volume controlled, ACV, electronic PEEP Ventilation with ambient air Stand-by mode at end case Direct

More information

Table of Contents. REMstar Auto User Manual 1

Table of Contents. REMstar Auto User Manual 1 Table of Contents Symbol Key... 2 Intended Use & Contraindications... 3 Specifications... 4 Warnings & Cautions... 5 System Features... 7 First Time Setup... 8 Installing the Filter... 9 Device Settings...

More information

Trilogy200. Proximal pressure line. Exhalation valve line. Quick start guide. Overview. Circuit set-up. Set-up screen. Prescription set-up

Trilogy200. Proximal pressure line. Exhalation valve line. Quick start guide. Overview. Circuit set-up. Set-up screen. Prescription set-up Trilogy200 Proximal pressure line Exhalation valve line Quick start guide 1 2 3 4 Overview Circuit set-up Set-up screen Prescription set-up 1 Overview 4 Porting block Detachable battery Air inlet and grey

More information

Pipe Cutting and Beveling Clamshells

Pipe Cutting and Beveling Clamshells Pipe Cutting and Beveling Clamshells Who We Are One Company, Total Support, Complete Solutions For more than a century, Hydratight has provided world-class bolted joint solutions and continues to set international

More information

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS Manual No. BLWR043 Rev. 4 September 2012 OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS CVF-8AC CVF-8AC50 CVF-6ACAN CVF-15ACAN CVF-25ACAN CVF-8A15KIT CVF-8A25KIT MODELS: CVF-8DC CVF-6DCAN CVF-15DCAN CVF-25DCAN

More information

RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05

RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05 RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,

More information

Ventilator Application of the Passy-Muir Valve David A. Muir Course Outline Benefits Review of the Biased Closed Position No Leak Passy-Muir Valves

Ventilator Application of the Passy-Muir Valve David A. Muir Course Outline Benefits Review of the Biased Closed Position No Leak Passy-Muir Valves Ventilator Application of the Passy-Muir Valve Michael S. Harrell, B.S., RRT Director of Clinical Education-Respiratory mharell@passy-muir.com (949) 833-8255 David A. Muir 23 year-old ventilator dependent

More information

Product overview Air conditioning service units

Product overview Air conditioning service units Product overview Air conditioning service units 02 03 AIR CONDITIONING SERVICE UNITS FROM ROBINAIR ARE THE WORLD S MOST ADVANCED AND MOST POPULAR AIR CONDITIONING SERVICE UNITS FOR CARS; TRUCKS AND BUSSES.

More information

M Series with C-Flex

M Series with C-Flex M Series with C-Flex IMPORTANT! Fill in the information below when you receive the REMstar Auto M Series system. Serial No.: (located on the bottom of the device) System Prescribed for: Date of Purchase

More information

BiPAP Auto Bi-Flex USER MANUAL

BiPAP Auto Bi-Flex USER MANUAL BiPAP Auto Bi-Flex USER MANUAL 2010 Koninklijke Philips Electronics N.V. All rights reserved. Table of Contents Intended Use... 2 Important... 2 Warnings... 2 Cautions... 3 Contraindications... 3 Symbol

More information

Compact Nasal CPAP Model 7400. System Patient Operating Instructions. Compact CPAP System

Compact Nasal CPAP Model 7400. System Patient Operating Instructions. Compact CPAP System 7400-00B.QXD 10/21/99 8:03 AM Page 1 The Respironics Tranquility Quest Plus is a medical device prescribed by a physician to assist breathing. Compact CPAP System Compact Nasal CPAP Model 7400 System Patient

More information

BiPAP Pro Bi-Flex USER MANUAL

BiPAP Pro Bi-Flex USER MANUAL BiPAP Pro Bi-Flex USER MANUAL 2012 Koninklijke Philips Electronics N.V. All rights reserved. Table of Contents Intended Use... 2 Important... 2 Warnings... 2 Cautions... 3 Contraindications... 3 Symbol

More information

Diagram of components 2. Reducer..3

Diagram of components 2. Reducer..3 Index Diagram of components 2 Reducer..3 Rail Filter - Rail Filter 4 - MAP Sensor.4 Injector & Nozzle - Single Injector / Rail Injector...5 - Bi-Fuel Connector...6 - Nozzle...7 ECU...8 Switch 9 Wiring

More information

SUCTION & TUBING YANKAUER, POOLE, FRAZIER AND SIGMOID INSTRUMENTS PREMIUM CONNECTORED AND ECONOMY ROLL TUBING

SUCTION & TUBING YANKAUER, POOLE, FRAZIER AND SIGMOID INSTRUMENTS PREMIUM CONNECTORED AND ECONOMY ROLL TUBING SUCTION INSTRUMENTS & TUBING YANKAUER, POOLE, FRAZIER AND SIGMOID INSTRUMENTS PREMIUM CONNECTORED AND ECONOMY ROLL TUBING A complete line of quality, disposable Suction Instruments and Tubing to meet your

More information

BACKPACK SPRAYERS. MODEL NOS: KSP16 & KSP20 Part Nos: 3402270 & 3402275 OPERATING & MAINTENANCE INSTRUCTIONS GC04/12

BACKPACK SPRAYERS. MODEL NOS: KSP16 & KSP20 Part Nos: 3402270 & 3402275 OPERATING & MAINTENANCE INSTRUCTIONS GC04/12 BACKPACK SPRAYERS MODEL NOS: KSP16 & KSP20 Part Nos: 3402270 & 3402275 OPERATING & MAINTENANCE INSTRUCTIONS GC04/12 INTRODUCTION Thank you for purchasing this CLARKE Sprayer, designed for use only with

More information

Climate chamber with illumination

Climate chamber with illumination KBWF series (E5.2) Climate chambers with illumination Climate chamber with illumination The BINDER climate chamber with illumination of the KBW series achieves homogeneous light distribution with its natural

More information

Oxygenation and Oxygen Therapy Michael Billow, D.O.

Oxygenation and Oxygen Therapy Michael Billow, D.O. Oxygenation and Oxygen Therapy Michael Billow, D.O. The delivery of oxygen to all body tissues is the essence of critical care. Patients in respiratory distress/failure come easily to mind as the ones

More information

MACHINES RECOVERY SYSTEMS SUPEREVAC CHARGING HOSES VACUUM AND HOSE ADAPTERS, VALVES AND PARTS CHARGING SYSTEMS GAUGES INSTRUMENTS ELECTRONIC

MACHINES RECOVERY SYSTEMS SUPEREVAC CHARGING HOSES VACUUM AND HOSE ADAPTERS, VALVES AND PARTS CHARGING SYSTEMS GAUGES INSTRUMENTS ELECTRONIC RECOVERY SUPEREVAC 29 RECOVERY 1/4" 4-IN-1 BALL VALVE TOOL For vacuum, charge, cores and recovery 18997 18975 18971 18978 18979 Remove and replace Schrader cores without losing charge. Extra 1/4" side

More information

SELECTION, APPLICATION & MAINTENANCE

SELECTION, APPLICATION & MAINTENANCE DIESEL PROTECTION SYSTEMS SVX-Series Diesel Engine Shut Down Valves (Solenoid Latched Types with Manual Start Override/Emergency Stop) SELECTION, APPLICATION & MAINTENANCE Valve Numbers SVX-340 SVX-350

More information

GE Healthcare. Avance Carestation. Innovating with you, shaping exceptional care

GE Healthcare. Avance Carestation. Innovating with you, shaping exceptional care GE Healthcare Avance Carestation Innovating with you, shaping exceptional care Clinician inspired perioperative solutions GE s Avance Carestation was developed using an approach to perioperative solutions

More information

GROENEVELD AUTOMATIC GREASING SYSTEMS

GROENEVELD AUTOMATIC GREASING SYSTEMS GROENEVELD AUTOMATIC GREASING SYSTEMS TWIN Parts & Accessories Book Pumps, Fittings, Injectors, Lining, etc. www.groeneveld-group.com 1 TWIN ELECTRICAL Item Part # Description 1 F113966 Switch 24V 2 F122991

More information

Infrarot-Bewegungsmelder IP44

Infrarot-Bewegungsmelder IP44 Infrarot-Bewegungsmelder IP44 infrared motion sensors IP44 ODA (weiß) slim ODA (schwarz) slim 95174 96000 ODA (weiß) ODA (schwarz) 95175 96001 Betriebsanleitung User s Manual User s Manual infrared motion

More information

Coloplast Product Guide Ostomy, Continence, Wound & Skin Care. Effective March 2010

Coloplast Product Guide Ostomy, Continence, Wound & Skin Care. Effective March 2010 Coloplast Guide Ostomy, Continence, Wound & Skin Care Effective March 2010 SpeediCath TM Intermittent Catheters The only ready-to-use hydrophilic catheter. Clinical research indicated that twice as many

More information

Vacuum mattress, Bariatric Transfer, Monitoring Documents Lisa Curatolo / Pete Davis Reviewer Stephen Hearns / Alistair Kennedy

Vacuum mattress, Bariatric Transfer, Monitoring Documents Lisa Curatolo / Pete Davis Reviewer Stephen Hearns / Alistair Kennedy Emergency Medical Retrieval Service (EMRS) www.emrs.scot.nhs.uk Standard Operating Procedure Public Distribution Title Packaging Version 9 Related Vacuum mattress, Bariatric Transfer, Monitoring Documents

More information

PORTABLE AIR CONDITIONER

PORTABLE AIR CONDITIONER VERY IMPORTANT! MODEL: GDC-AC9RW / GDC-AC9RCS GDC-AC9RCW / GDC-AC12RW GDC-AC12RB / GDC-AC12RCB GDC-AC12RCW INSTRUCTIONS FOR USE PORTABLE AIR CONDITIONER Do not install and use your portable air conditioner

More information

NEW SIX-SEALS CUTTING RING. INTERNATIONAL INDUSTRIAL PATENT Nr. 864061 of the 10/03/99 FLANKS AND DOES NOT REPLACE THE STANDARD RING CURRENTLY IN USE

NEW SIX-SEALS CUTTING RING. INTERNATIONAL INDUSTRIAL PATENT Nr. 864061 of the 10/03/99 FLANKS AND DOES NOT REPLACE THE STANDARD RING CURRENTLY IN USE B4 NEW SIX-SEALS CUTTING RING. INTERNATIONAL INDUSTRIAL PATENT Nr. 864061 of the 10/03/99 FLANKS AND DOES NOT REPLACE THE STANDARD RING CURRENTLY IN USE AVAILABLE IN CARBON AND STAINLESS STEEL 23 THEORY

More information

I have sleep apnea. Now what? A guide to getting the most out of your treatment

I have sleep apnea. Now what? A guide to getting the most out of your treatment I have sleep apnea. Now what? A guide to getting the most out of your treatment Equipment replacement schedule To get the most benefit from your PAP therapy, your equipment should be replaced when necessary

More information

Ministry of Health and Long Term Care Assistive Devices Program (ADP) Changes to How the ADP Funds Positive Airway Pressures Systems

Ministry of Health and Long Term Care Assistive Devices Program (ADP) Changes to How the ADP Funds Positive Airway Pressures Systems Q1 What prices is the changing? A1 The ADP is reducing the ADP approved price for all ADP funded PAP systems: the Program will reduce the ADP approved price for a Continuous Positive Airway Pressure (CPAP)

More information

Knee Osteoarthritis Braces

Knee Osteoarthritis Braces Knee Osteoarthritis Braces Helping you face today s challenges. Custom Braces OA DEFIANCE MONTANA 2 OA ADJUSTER 1 Millions of adults have knee osteoarthritis. In many cases, this chronic condition limits

More information

Vacuum drying oven for non-flammable solvents

Vacuum drying oven for non-flammable solvents VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.

More information

Influence of Belt Furnace on Glass-to-Metal Seal Process

Influence of Belt Furnace on Glass-to-Metal Seal Process Influence of Belt Furnace on Glass-to-Metal Seal Process Introduction The glass, under suitable conditions, will bond well to a wide variety of metals and alloys which has led to the development of many

More information