1 Mask Information Guide
2 Welcome to your handy guide to ResMed masks Here you ll find mask selection information, fitting guides, product codes, product features and benefits for the full range of ResMed mask systems - pillows, nasal, full face, non-vented and disposable. Only from ResMed - world leaders in mask technology. contents SELECTING A MASK NASAL PILLOWS NASAL MASKS FULL FACE MASKS NON-VENTED MASKS DISPOSABLE MASKS TECHNICAL SPECIFICATIONS Mask/Device Compatibility USE AND CARE
3 Mask Type 1 Past nasal / soft palate surgery (e.g. UPPP)? NO YES Selection Select the appropriate mask type by following the flow diagram on the right. Ideally, the patient should choose their preferred mask with clinical guidance. 2 Rhinitus? Sinusitis? Hay Fever? NO YES No Humidifier YES With Humidifier Useful tips A full face mask is preferable for patients with mouth leak. 3 Other nasal symptoms (e.g. Mouth breathes)? NO YES If a full face is not required, a nasal system should be first choice. Pillows should be considered as the nasal mask of choice. 4 Claustrophobic? Skin conditions / allergies? NO YES Swift TM LT 5 Active sleep? Poor fit in past / present? YES Mirage Activa TM LT NO Mirage Quattro TM OR Swift LT OR Mirage Activa LT Mirage Liberty TM OR Mirage Micro TM SELECTING A MASK
4 Mask Size Selection Select the appropriate mask size by following the instructions. The range of sizes ensures that every patient can achieve optimal fit. Useful tips The 2D sizing templates will help you determine the optimal cushion size. If the template opening is too close to their nares or nasal perimeter, that size cushion is incorrect and may cause the patient to experience discomfort from pressure on the nasal bridge or cheek bones. Incorrect cushion size can also lead to leak into the eyes or around the nose. SELECTING A MASK
5 Mask Size Mirage Micro NASAL MASK Mirage Activa LT NASAL MASK Ultra Mirage TM NASAL MASK II Mirage Activa NASAL MASK Place the fitting template around the nose and align arrow to bottom of the nose. Obtain a close fit around the nose allowing some clearance around the nostrils and the nasal bridge. SELECTING A MASK
6 Mask Size Mirage Quattro FULL FACE MASK Align the fitting template to chin crease. Determine cushion size according to the position of the corner of the eye. Mirage Liberty FULL FACE MASK Align the fitting template to bottom of the nose. Check the position of the chin crease above or below the dotted line. If the chin crease is above dotted line, then choose the small cushion. If the chin crease is below dotted line, then choose the large cushion. SELECTING A MASK
7 Complete mask system Tube retainer (optional) Top buckle/s (1) (10) Frame Back buckle/s (1) (10) Short tube assembly (short tube, elbow and swivel) Pillows (XS) (S) (M) (L) Headgear assembly (headgear, buckles) Product packed with S, M and L pillows. XS sold separately. NASAL PILLOWS
8 Quick fitting guide Minimal contact, optimal seal The first nasal pillows with ResMed s proven dual-wall technology. The pillows rest on a flexible cushion base maintaining seal. Freedom to move and sleep on the side Headgear with flexible stabilising elements gently holds the system in place when user turns or moves during sleep. The cushion base enables the dual-wall pillows to move in different directions without compromising seal or creating leaks. Super-quiet and personalised comfort Air is dispersed gently through the fine vents. The innovative vent design directs air away from the user and their partner Holding the pillows at your nose, pull the headgear over your head. Headgear should sit midway between the ears and eyes. 4 5 Using the click-fit adjustor, position the nasal pillows at the most suitable angle. Connect the Swift LT short tube to the device air tubing. Turn on the device. Adjust the top straps by pulling them evenly until comfortable. Do not overtighten. The Swift LT is now fitted and ready for use. Do not overtighten headgear straps Repeat Step 2 with the back straps. Do not overtighten. Optional For alternate tubing positions, use the tube retainer. To attach, push it into the top headgear buckle. Clip in either the short tube or device air tubing, depending on flexibility needs. The tubing can be positioned to either side of your face or centered. If the pillows pull on your nose, adjust the tubing at the tube retainer. NASAL PILLOWS
9 Complete mask system Pillow sleeve (S) (M) (L) Short tube assembly/ies (1) (10) Frame system (no headgear) (S) (M) (L) Tube retainer (3) Distal pressure part (1) (10) Headgear buckles (4) Headgear Clip Frame with clip and cap Seal rings (10) 1 Product packed with S, M & L pillows. Cap NASAL PILLOWS
10 Dial Forehead support Forehead pad/s (1) (10) Headgear (S) (Std) (L) 3 Elbow assembly Ports cap (2) (10) Mask cushion (S) (M) (L) (LW) (XL) Elbow Swivel Mask frame (Std) (S) 1 Headgear clips (2) (10) 1 Small cushion and frame are only compatible with each other. 2 Standard headgear supplied with all sizes of complete mask assembly. Small Medium Large Large-Wide Extra-Large 3 Small (16118) and Large (16119) headgear come without clips NASAL MASKS
11 Quick fitting guide Intuitively easy Easy removal of cushion and elbow from frame (no cushion or elbow clip). Easy one-hand adjustment of the forehead support with the MicroFit dial Personalised fit and comfort Allows for optimum, accurate fit with a turn of the MicroFit dial. Mirage Micro dual-wall cushions now come in five sizes, to fit 95% of patients 1. Turn MicroFit dial to position 24. Disconnect one headgear clip. Place mask on face, slide headgear on. Reconnect lower headgear clip. Quiet, sleek and stylish Quieter than a soft whisper. Less obtrusive with minimalist forehead support. 1 Based on internal anthropometric database (n=267) Unfasten upper tabs, pull until comfortable. Reattach the tabs. Repeat step 4 with lower straps. Connect tube to mask and flow generator. Start flow generator. Turn MicroFit dial to eliminate leaks. Do not overtighten headgear straps NASAL MASKS
12 Forehead support pad/s (1) (10) Dial Forehead support Mask frame Mask cushion and clip (M) (L) (LW) Elbow Elbow assembly (elbow, swivel): Swivel Clip Ports cap (2) (10) Headgear clips (2) (10) Headgear (S) (Std) (L) 2 Medium Large Large-Wide 1 Standard headgear supplied with all sizes of complete mask assembly. 2 Small (16118) and Large (16119) headgear come without clips NASAL MASKS
13 Quick fitting guide ActiveCell Technology The unique cushion features an active cell that automatically expands and contracts to suit user movements and varying pressures throughout the night. Ideal for active sleepers; ActiveCell Technology provides dynamic defence against leak. A fine-tuned fit MicroFit dial provides easy, one-handed forehead support adjustment. Less dependant on headgear tension and adjustment to achieve an effective seal (quicker fitting time, less callbacks and improved user compliance). The quiet achiever Innovative diffuse vent design, disperses air quietly and softly, at a short distance, away from the bed partner. Located on the elbow for easy cleaning and disassembly. Do not overtighten headgear straps Turn the MicroFit dial to position 24, so that the forehead support is fully extended Allow room for the cushion s active cell to inflate. Use two fingers as a guide. Disconnect the lower headgear clip, hold the mask over the nose and pull the headgear over the head. Reconnect the lower headgear clip ensuring it clicks into place. Turn on the airflow device. If the mask is fitted correctly, the cushion should be smooth and the active cell (highlighted) fully inflated. Connect one end of the air tubing to the swivel and the other end to the airflow device. While lying down, adjust the dial for comfort and seal. If fitted incorrectly, the cushion will be creased and the active cell underinflated. NASAL MASKS
14 Headgear (S) (Std) (L) 3 Elbow clip (10) Frame Frame assembly (no cushion and headgear) Forehead support with pads Forehead pad/s (1) (10) Cushion (Std) (L) (Sh) (Sh-W) Vent cover Elbow assembly Swivel Ports cap (2) (10) Headgear clips (2) (10) Cushion clip Complete mask system comes with standard sized headgear. 2 Elbow assembly includes elbow clip, vent cover, elbow and swivel. 3 Small (16118) and Large (16119) headgear come without clips. Standard Large Shallow Shallow-Wide NASAL MASKS
15 Quick fitting guide Seal and comfort Mirage dual-wall cushion reduces pressure on nasal bridge and optimises seal and comfort. Forehead support provides seal and stability with a choice of four clearly numbered positions. Easy to use Headgear clips allow quick attachment/ detachment of headgear - no further adjustments required after initial fitting Disconnect one headgear clip. Ensure that forehead support tab is in position 1. Place mask on face and pull headgear over head. Make sure upper straps pass across forehead and lower straps below ears. Reattach headgear clip to mask frame. Gently tighten upper headgear straps. The forehead support pads should lightly touch the forehead. Do not overtighten straps. Gently tighten lower headgear straps. Do not overtighten straps. Ultra-quiet Vent design minimises airflow intensity and noise. Specially designed to direct air away from user and partner, and provide optimum CO 2 washout. 1 Based on internal anthropometric database (n=267) Connect one end of air tubing to mask swivel and other end to flow generator. Turn flow generator on. If air leaks around cushion you may need to make some adjustments. In this case, proceed to step 5. Loosen upper headgear straps and move forehead support tab to another position (eg, position 2). Gently tighten upper headgear straps. Test all four positions of forehead support tab and adjust headgear straps until you achieve a secure and comfortable fit. Do not overtighten headgear straps NASAL MASKS
16 Forehead pad/s (1) (10) Mask frame Forehead support Elbow assembly (including exhaust vent) Cushion (Std) (L) (Sh) Inlet tube and swivel assembly (1) (10) Ports caps (2) (10) Headgear clip/s (2) (10) Cushion clip Headgear (Including headgear clips) (S) (Std) (L) 1 Swivel assembly (10) 1 Small (16118) and Large (16119) headgear come without clips. 2 Standard headgear supplied with all sizes of complete mask assembly. Standard Large Shallow NASAL MASKS
17 Unobtrusive design Age 7 or over Headgear Headgear clips Cushion Elbow assembly 1 Frame (Std) (2), (10) (Std), (Dp) Crossover buckle Cushion 2 Headgear 2 Headgear clips (1), (10) (S) (S) (2), (10) Standard Deep Small These parts are common with the Kidsta. 2 The cushion and headgear on the Kidsta can be used with the Vista. NASAL MASKS
18 1 Ultra Mirage NV FULL FACE MASK Effective and comfortable 3 Ultra Mirage NV NASAL MASK A more unobtrusive option for NIV Frame (S) (M) (L) Elbow Headgear Elbow assembly Frame Forehead support Forehead pad/s (2) (10) Tube connector/s (1) (10) S-Std M-Std L-Std Standard Large Shallow S-Sh M-Sh L-Sh Common parts with Ultra Mirage Full Face Mask: forehead pads, headgear clips, cushion & clips,elbow retainer, forhead support and ports caps. 2 This part is common with Ultra Mirage Nasal Mask NV. 3 Common parts with Ultra Mirage II: cushion & clip, elbow clip, headgear clips & ports cap. NON-VENTED MASKS
19 Disposable NASAL MASK A more unobtrusive option for NIV Disposable FULL FACE MASK Easy to seal Headgear (10) Medium Large Small Medium Large Disposable NV FULL FACE MASK For use with a leak circuit Headgear (10) Small Medium Large DISPOSABLE MASKS
20 Technical Specifications Ultra Mirage II Nasal Mirage Quattro, Mirage Liberty, Ultra Mirage, Hospital Full Face Mask Mirage Swift II Nasal Pillows Swift LT Nasal Pillows TECHNICAL SPECIFICATIONS
21 Mask Device Compatibility The table below specifies the masks compatible with ResMed s positive airway pressure devices and the mask setting, if one is required. For full details regarding the correct use of these devices, please refer to the specific User Guides. Nasal Pillows Mirage Swift II Swift LT S7 AutoSet Spirit MIRAGE MIRAGE S8 AutoSet Spirit II SWIFT SWIFT S8 Escape II No setting required. Consult your clinician before changing to a different mask type. VPAP III Series MIRAGE MIRAGE AutoSet CS 2 N/V N/V N/V = The mask has not been validated for this device. Mask Device Compatibility
22 Mask Device Compatibility The table below specifies the masks compatible with ResMed s positive airway pressure devices and the mask setting, if one is required. For full details regarding the correct use of these devices, please refer to the specific User Guides. Nasal Masks Mirage Micro Ultra Mirage II Activa LT Mirage Activa Mirage Vista Mirage Kidsta S7 AutoSet Spirit STANDARD ULTRA STANDARD STANDARD STANDARD STANDARD S8 AutoSet Spirit II STANDARD ULTRA ACTIVA ACTIVA STANDARD STANDARD S8 Escape II No setting required. Consult your clinician before changing to a different mask type. VPAP III Series STANDARD ULTRA STANDARD STANDARD STANDARD STANDARD AutoSet CS 2 VISTA ULTRA ACTIVA ACTIVA VISTA N/V N/V = The mask has not been validated for this device. Mask Device Compatibility
23 Mask Device Compatibility The table below specifies the masks compatible with ResMed s positive airway pressure devices and the mask setting, if one is required. For full details regarding the correct use of these devices, please refer to the specific User Guides. Full Face Masks Mirage Quattro Mirage Liberty Ultra Mirage S7 AutoSet Spirit MIR FULL MIR FULL MIR FULL S8 AutoSet Spirit II MIR FULL MIR FULL MIR FULL S8 Escape II No setting required. Consult your clinician before changing to a different mask type. VPAP III Series MIR FULL MIR FULL MIR FULL AutoSet CS 2 FULL FACE FULL FACE FULL FACE Mask Device Compatibility
24 Mask Device Compatibility The table below specifies the masks compatible with ResMed s positive airway pressure devices and the mask setting, if one is required. For full details regarding the correct use of these devices, please refer to the specific User Guides. Disposable Masks Hospital Nasal Hospital Full Face S7 AutoSet Spirit STANDARD MIR FULL S8 AutoSet Spirit II STANDARD MIR FULL S8 Escape II No setting required. Consult your clinician before changing to a different mask type. VPAP III Series N/V MIR FULL AutoSet CS 2 VISTA FULL FACE N/V = The mask has not been validated for this device. Mask Device Compatibility
25 Use and Care GUIDE CLEANING Daily The cushion and frame should be wiped daily with a damp cloth. Weekly The mask system should be washed a minimum of once per week. Separate and hand wash mask components (including tubing) in lukewarm, soapy water (original washing up liquid is recommended). Rinse well and allow to air dry out of direct sunlight, not on a radiator. Hand-wash headgear separately. Caution Do not use solutions containing bleach, chlorine, alcohol, aromatics, moisturisers, antibacterial agents or scented oils to clean the mask or tubing. These solutions may reduce the life of the mask (life expectancy is 1 year). If any visible deterioration of a mask component is apparent (cracking, crazing, tears, etc), the mask component should be discarded and replaced. DISINFECTION Validated disinfection / sterilisation procedures High level thermal disinfection. High level chemical disinfection. STERRAD sterilisation. Parts that cannot be disinfected / sterilised Swivel, short tubing Mirage (vented & non-vented) Nasal Mask. Swivel, inlet tube Mirage Activa, Kidsta, Vista Nasal Masks & Liberty Full Face Mask. Valve membrane Mirage Nasal Mask, Mirage S2 & Ultra Mirage Full Face Mask. All components, excluding the above, can be recycled over 15 times. The Mirage Quattro, Mirage Liberty and Mirage Micro can be recycled over 20 times. Further detailed information can be found on USE AND CARE
Do not use soaps with added scents. We recommend plain Ivory liquid soap or baby shampoo. Rinse well and allow to air dry out of direct sunlight.
ResMed CPAP Mask FAQ When and how should I clean my mask? Daily Wash the mask system with warm, soapy water. Do not use soaps with added scents. We recommend plain Ivory liquid soap or baby shampoo. Rinse
More informationResMed Mask Materials January 2009
ResMed Mask s January 2009 PRODUCT BULLETIN Bulletin Number: 590 Month/Year: January 2009 Distribution: Global Date of implementation: Immediately Replaces Product Bulletin #578 Following are details of
More informationMirage FX NASAL MASK. User Guide
Mirage FX NASAL MASK User Guide Mirage FX NASAL MASK Fitting// 1 2 3 4 5 6 Mirage FX i Removal// 1 2 Disassembly// 1 2 3 ii Reassembly// 1 2 3 4 iii Mirage FX A 2 3 1 4 7 6 5 B iv Mask components// Item/
More informationResMed Mask Materials December 2010-12-16
ResMed Mask s December 2010-12-16 PRODUCT BULLETIN Bulletin Number: #679 Month/Year: January 2011 Distribution: Patient Interface Product Managers World-Wide Date of implementation: Immediately Replaces
More informationMirage FX. User Guide. English NASAL MASK
Mirage FX NASAL MASK User Guide English Did you know? Replacing your mask and supplies is one of the most important steps in maintaining effective therapy. Replace when... The cushion is no longer clear
More informationResMed Masks. Clinical Use Only. Disinfection and Sterilization Guide. NASAL MASKS Mirage Activa. Mirage Kidsta. Mirage Vista.
ResMed Masks and Sterilization Guide S Mirage Activa Mirage Kidsta Mirage Vista Ultra Mirage II Ultra Mirage NON-VENTED NASAL PILLOWS SYSTEMS Mirage Swift II NEW NASAL PILLOWS SYSTEM Mirage Swift NASAL
More information1. CPAP: delivers continuous flow of air at a constant pressure.
What does CPAP stand for? CPAP stands for Continuous Positive Airway Pressure. What does CPAP therapy do? CPAP therapy provides a constant airflow which holds the airway open so that uninterrupted breathing
More informationLiberty Home Care Services
Liberty Home Care Services Personal Health Solutions Ostomy PAGES 5-73 PAGES 75-87 Continuous Positive Air Pressure Urological PAGES 89-115 Diabetes PAGES 119-126 FREE SHIPPING and a NO-RISK GUARANTEE
More informationNational Hospital for Neurology and Neurosurgery. Continuous positive airway pressure (CPAP) Sleep Respiratory Unit
National Hospital for Neurology and Neurosurgery Continuous positive airway pressure (CPAP) Sleep Respiratory Unit If you would like this document in another language or format or if you require the services
More informationPATIENT GUIDE. Care and Maintenance Drainage Frequency: Max. Drainage Volume: Dressing Option: Clinician s Signature: Every drainage Weekly
PATIENT GUIDE Care and Maintenance Drainage Frequency: Max. Drainage Volume: Dressing Option: Every drainage Weekly Clinician s Signature: ACCESS SYSTEMS Pleural Space Insertion Site Cuff Exit Site Catheter
More informationNo Other Sleep Therapy System Delivers More.
COMFORT STYLE INNOVATION No Other Sleep Therapy System Delivers More. Only the ResMed S9 Series Gives You More Comfort, Style and Sleep. About sleep apnea Obstructive sleep apnea (OSA) is a common form
More informationUSING YOUR CPAP AT HOME
USING YOUR CPAP AT HOME You have been provided with CPAP equipment to treat your sleep apnoea. The following information aims to answer any questions you may have about sleep apnoea and the use of CPAP
More informationThis information is also available on our website www.barkersleep.com
Welcome to the Barker Sleep Institute s PAP user manual Inside are helpful tips for successful PAP therapy including: Solutions to common questions Cleaning of PAP equipment Parts replacement schedule
More informationI have sleep apnea. Now what? A guide to getting the most out of your treatment
I have sleep apnea. Now what? A guide to getting the most out of your treatment Equipment replacement schedule To get the most benefit from your PAP therapy, your equipment should be replaced when necessary
More informationLiving with positive airway pressure treatment
Living with positive airway pressure treatment ResMed Corp San Diego, CA, USA +1 858 836 5000 or 1 800 424 0737 (toll free). ResMed Ltd Bella Vista, NSW, Australia +61 (2) 8884 1000 or 1 800 658 189 (toll
More informationWhat you should know
What you should know Important mask information for your sleep therapy How long does a CPAP mask typically last? Sleep therapy masks used in the home tend to last three to six months depending on several
More informationReplacing your CPAP supplies for a better night s sleep.
Replacing your CPAP supplies for a better night s sleep. ResMed.com Understanding the risks Patients who regularly replace their CPAP supplies not only sleep for more hours through the night, they also
More informationPATIENT GUIDE. Care and Maintenance Drainage Frequency: Max. Drainage Volume: Dressing Option: Clinician s Signature: Every drainage Weekly
PATIENT GUIDE Care and Maintenance Drainage Frequency: Max. Drainage Volume: Dressing Option: Every drainage Weekly Clinician s Signature: ACCESS SYSTEMS Pleural Space Insertion Site Cuff Exit Site Catheter
More informationIMPORTANT INSTALLATION GUIDE VALENCIA SQUARE CORNER SHOWER READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING THE INSTALLATION
INSTALLATION GUIDE VALENCIA SQUARE CORNER SHOWER SEALANT REQUIRED TO COMPLETE THIS INSTALLATION: (Not supplied) Sika Sikasil NG (Arctic White) To seal the WHITE shower door and returns to the shower tray.
More informationMayo Clinic Store. Sleep Apnea. Solutions for Healthier Living 2015-2016 Medical Supplies Catalog
Mayo Clinic Store Sleep Apnea Solutions for Healthier Living 2015-2016 Medical Supplies Catalog Table of Contents Equipment....3 Masks....8 Accessories....24 Sleep Apnea Equipment Cleaning & Tips...28
More informationDMSG_0152_0112_V4 Mamas & Papas (Holdings) Ltd. 2012 Dream Swing - 1 -
DMSG_0152_0112_V4 Mamas & Papas (Holdings) Ltd. 2012 Dream Swing - 1 - DREAM SWING THESE INSTRUCTIONS ARE IMPORTANT. PLEASE READ CAREFULLY AND RETAIN FOR FUTURE REFERENCE. Read the entire instruction before
More informationWHEN THINGS GO WRONG WITH CPAP
1 The Sleep Center at Rocky Mountain Heart and Lung A Department of Kalispell Regional Medical Center 350 Heritage Way, Suite 2100, Kalispell, Montana 59901 (406) 257 8979 Fax (406) 257 8964 WHEN THINGS
More informationpc-6 humantouch.com use & care manual 800.355.2762
pc-6 800.355.2762 2009 Human Touch, LLC. Patents pending and intellectual property rights enforced. No medical claims are warranted or implied by the use of this product. Human Touch is a trademark of
More informationPOP Pushchair. Instructions
POP Pushchair Instructions Important: Keep for future reference Please read these instructions carefully before using your new pushchair Keep them in a safe place so that you may use them in the future
More informationSystem One Heated Humidifier USER MANUAL
System One Heated Humidifier USER MANUAL 2011 Koninklijke Philips Electronics N.V. All rights reserved. Table of Contents Intended Use... 2 Warnings... 2 Cautions... 2 Contraindications... 3 Symbol Key...
More informationMini multi-purpose sewing machine
TROUBLESHOOTING Problem Problem cause Amendment No power or the machine runs slowly Batteries are installed incorrectly Batteries are low Reinstall the batteries making sure they are the correct way around
More informationCaring for Your PleurX Pleural Catheter
Caring for Your PleurX Pleural Catheter A PleurX Pleural Catheter has been placed in your chest through a small incision in your skin into the pleural space (see picture below). This allows you to drain
More informationInstruction manual EAR SET 1 EAR SET 4
Instruction manual EAR SET 1 EAR SET 4 Contents Safety instructions... 2 Delivery includes... 3 Ear Set 1... 3 Ear Set 4... 3 Ear Set 1 / Ear Set 4... 4 Features of the Ear Set 1 / Ear Set 4... 4 Putting
More informationLunette 2 Series. Curved Fixed Frame Projection Screen. User s Guide
Lunette 2 Series Curved Fixed Frame Projection Screen User s Guide Important Safety and Warning Precautions Please follow these instructions carefully to ensure proper maintenance and safety with your
More informationON TRACK Reprocessing Inservice / Competency for GI Endoscopes (EVIS, EXERA, EXERA II)
THIS CHECKLIST IS DESIGNED FOR USE SOLELY AS A CUSTOMER EDUCATIONAL TOOL, AND IS NOT INTENDED TO REPLACE OR ANY WAY MODIFY THE OLYMPUS INSTRUCTION MANUAL/REPROCESSING MANUAL. BE SURE TO FOLLOW THE DETAILED
More informationIntroduction. Intended use. Contraindications. General warnings and cautions. Patient Instructions WARNING CAUTION. English
Patient Instructions English Introduction ApneaLinkAir ApneaLink Plus Your physician or healthcare provider has given you the ApneaLink Air device to test if you have sleep-disordered breathing. The device
More informationPROCEDURE FOR USING A NASAL CANNULA
PROCEDURE FOR USING A NASAL CANNULA A nasal cannula is used to deliver a low to moderate concentration of oxygen. It can be used as long as nasal passages are open. A deviated septum, swelling of the nasal
More informationX-Plain Foley Catheter Male Reference Summary
X-Plain Foley Catheter Male Reference Summary Introduction A Foley catheter is a tube that is put through the urinary opening and into your bladder to drain urine. Your doctor may have placed or may ask
More informationInformation for patients and nurses
Information for patients and nurses Rocket IPC Pleural Catheter Indwelling Catheter Rocket Indwelling Pleural Catheter (IPC) Contents Contact Information...03 What s in the Rocket Dressing Pack and Bottle
More informationIMPORTANT INFORMATION - PLEASE READ. Table of Contents. Introduction. General Information
IMPORTANT INFORMATION - PLEASE READ Introduction Congratulations! Welcome to the world of the ELLIPTICAL CROSS TRAINER. The ELLIPTICAL CROSS TRAINER is one of the finest and most comprehensive pieces of
More informationPROCEDURE FOR USING A NASAL CANNULA
FOR USING A NASAL CANNULA A nasal cannula is used to deliver a low to moderate concentration of oxygen. It can be used as long as nasal passages are open. A deviated septum, swelling of the nasal passages,
More informationHAIR CLIPPER. Model No. HC5150 HC5150 2. 3.
All technical modifications reserved. 09/08. TSC 08.0634 HAIR CLIPPER 2. 3. 1. Model No. HC5150 4. 10/UK/HC5150 Version 03/10 Part No. T22-29458 REMINGTON is a Registered Trade Mark of Spectrum Brands,
More informationHEAD HARNESS & BUCKELS
THIS INSPECTION AND MAINTENANCE SHOULD BE PERFORMED AT LEAST ANNUALLY AND AS DICTATED BY CONDITION REVEALED DURING DAILY/MONTHLY INSPECTION. MONTHLY INSPECTIONS DETERMINE NECESSITY FOR OVERHAUL WITH MORE
More informationJabra BIZ 2400. User manual. www.jabra.com
Jabra BIZ 2400 User manual www.jabra.com 1 2012 GN Netcom A/S. All Rights Reserved. This user guide is published by GN Netcom A/S. The information in this user guide is furnished for informational use
More informationMirage SoftGel. User Guide. English. nasal mask
Mirage SoftGel nasal mask User Guide English Mirage TM SoftGel Rx Only / Sur prescription uniquement / Solamente bajo prescripción / Somente com prescrição médica Fitting / Mise en place / Colocación /
More informationCOOLING SYSTEM Section Page
5 COOLING SYSTEM Section Page 5.1 COOLANT PRE-HEATER... 5-3 5.2 COOLANT PUMP NON-EGR ENGINE... 5-7 5.3 COOLANT PUMP EGR ENGINE... 5-13 5.4 FRONT CONNECTOR HOUSING NON-EGR ENGINE... 5-17 5.5 FRONT CONNECTOR
More information2 (. 3 4 5 . -,.. -,. 3. : 1 2 3 > 4, :!! 1,, 17 Lt MAX 2 3 4,, > 5.,,, 6 :, :1)! 2)! 7,, 1, :,. 2,, Bottom of steam generator 7 8 9 10 11 12 automatically and this phenomenon will continue for
More informationKeeping your lungs healthy
Keeping your lungs healthy A guide for you after spinal cord injury and other neurological conditions Regional Rehabilitation Program This booklet has been written by the health care providers who provide
More informationAchieving Independence
Bard: Intermittent Self-Catheterization A Guide to Self-Catheterization Achieving Independence Introduction This brochure is provided by Bard, a leading provider of urology products since 1907. The best
More informationA Guide to Help You Manage Your Catheter and Drainage Bags
A Guide to Help You Manage Your Catheter and Drainage Bags A catheter can make a difference to your health and quality of life. We understand that it can be a big adjustment for you. This information will
More informationPRODUCT INTENDED USE:
PRODUCT INTENDED USE: The mattress overlays are intended for use with existing mattresses; they are not intended to replace existing mattresses. ROHO DRY FLOATATION Mattress Overlay and ROHO DRY FLOATATION
More informationKASK HELMET OWNER S USE & CARE MANUAL
KASK HELMET OWNER S USE & CARE MANUAL WARNING Athletic activities involving the use of this equipment are inherently dangerous. You are responsible for your own decisions and actions. Before using this
More informationCOUNTRYMAN E6 OMNIDIRECTIONAL EARSET MICROPHONE
COUNTRYMAN E6 OMNIDIRECTIONAL EARSET MICROPHONE Thanks for choosing the Countryman E6 Omnidirectional Earset microphone. We re confident you ll find the E6 Omni to be the finest, most natural sounding
More informationP6946 WARNING. www.fisher-price.co.uk. Rocker. Swing. IMPORTANT! KEEP INSTRUCTIONS FOR FUTURE REFERENCE. Infant Seat
P6946 Rocker Swing WARNING IMPORTANT! KEEP INSTRUCTIONS FOR FUTURE REFERENCE. Infant Seat www.fisher-price.co.uk Consumer Information WARNING To prevent injury or death from falls or being strangled in
More informationSOUND ISOLATING EARPHONES. Português INSTRUCTION MANUAL. Pусский
SE846 TM SOUND ISOLATING EARPHONES Português INSTRUCTION MANUAL Pусский SE846 Sound Isolating Earphones Shure Sound Isolating Earphones, built with balanced armature speakers, deliver a detailed soundstage
More informationSwift TM FX. User Guide. English. nasal pillows system
Swift TM FX nasal pillows system User Guide English Swift TM FX Fitting / Anlegen / Mise en place / Applicazione / Opzetten 1 2 3 4 5 6 1 Swift FX A 1 2 3 9 10 8 4 5 6 7 B C D 2 Mask components / Maskenkomponenten
More informationHeated HumidifieR 1031849 HM 1/6/06
Heated HumidifieR M Series USER Manual 1031849 HM 1/6/06 Table of Contents Introduction...3 In This Manual...3 Intended Use...3 Warnings and Cautions...3 Warnings...3 Cautions...4 Symbol Key...5 System
More informationENGINE FUEL FUEL FILTER... FUEL HEATER... INJECTOR... SUPPLY PUMP... COMMON RAIL... FUEL PRESSURE LIMITTER...
FUEL FILTER............................ FUEL HEATER.......................... INJECTOR.............................. SUPPLY PUMP.......................... COMMON RAIL.......................... FUEL PRESSURE
More informationAssembly Instructions
city versa Assembly Instructions Read these instructions carefully before use and keep them for future reference. Your child s safety may be affected if you do not follow these instructions. This product
More informationCall our CPAP/Bilevel team customer service
CPAP & Bilevel Therapy MedEQUIP - Home Care Services The Michigan Difference MedEQUIP - Home Care Services Our Services MedEQUIP EQUIPMENT SERVICES Call our CPAP/Bilevel team customer service CONTENTS
More informationwww.respironics.com CPAP System User Manual 1007167 LK 5/12/01
www.respironics.com CPAP System User Manual 1007167 LK 5/12/01 Table of Contents Symbol Key... 2 Intended Use... 3 Specifications... 4 Warnings & Cautions... 5 Unpacking the System... 6 System Features...
More informationBACKPACK SPRAYERS. MODEL NOS: KSP16 & KSP20 Part Nos: 3402270 & 3402275 OPERATING & MAINTENANCE INSTRUCTIONS GC04/12
BACKPACK SPRAYERS MODEL NOS: KSP16 & KSP20 Part Nos: 3402270 & 3402275 OPERATING & MAINTENANCE INSTRUCTIONS GC04/12 INTRODUCTION Thank you for purchasing this CLARKE Sprayer, designed for use only with
More informationEasyNote TJ Series. Disassembly Manual
EasyNote TJ Series Disassembly Manual CHAPTER3 Replacing notebook components Preventing static electricity discharge Preparing the work space Required tools Preparing the notebook Adding or replacing memory
More informationSwift FX for Her. User Guide. English. nasal pillows system
Swift FX for Her nasal pillows system User Guide English Rx only/ Sur prescription uniquement / Solamente bajo prescripción / Somente com prescrição médica Swift FX for Her Fitting / Mise en place / Colocación
More informationPARTS NEEDED FOR CONVERTING FROM LP TO NG
1 6 7 8 3 5 4 10 9 2 PARTS NEEDED FOR CONVERTING FROM LP TO NG Number Description 1 30" NG Manifold 2 NG side burner valve 3 NG Regulator 4 Rear I/R NG orifice 4 Rear I/R NG orifice 5 Side burner NG orifice
More informationSwift FX. User Guide. English NASAL PILLOWS SYSTEM
Swift FX NASAL PILLOWS SYSTEM User Guide English Swift FX Fitting / Anlegen / Mise en place / Applicazione / Opzetten 1 2 3 4 5 6 1 Swift FX A 1 2 3 10 11 9 4 6 5 7 8 B C D 2 Mask components / Maskenkomponenten
More informationDrive shaft, servicing
Volkswagen Passat B6 - Drive shaft, servicing Стр. 1 из 41 40-7 Drive shaft, servicing Drive shafts, overview I - Assembly overview: Drive axle with CV joint VL100 40-7, Drive axle with CV joint VL100,
More informationCHILD BOOSTER SEAT. Instructions for Installation & Use Series No. 4050/A/2013 IMPORTANT: KEEP THIS BOOK IN THE PLACE PROVIDED ON THE CHILD RESTRAINT
CHILD BOOSTER SEAT Instructions for Installation & Use Series No. 4050/A/2013 IMPORTANT: KEEP THIS BOOK IN THE PLACE PROVIDED ON THE CHILD RESTRAINT INDEX PAGE 3 4 6 7 9 10 14 19 21 22 INTRODUCTION WARNINGS
More informationFeaturing Blue Seal TM HANDLING WITH CARE. Safe Patient Handling Transfer and Turning
R Featuring Blue Seal TM HANDLING WITH CARE Safe Patient Handling Transfer and Turning HANDLING WITH CARE Featuring Blue Seal TM At last a One Way Slide that really works! Blue Seal TM All SlideAssist
More informationHardware Guide for the Classic and Elite CR Systems. 2011-08-04 PN 9G9637 Version 1.0
Hardware Guide for the Classic and Elite CR Systems 2011-08-04 PN 9G9637 Version 1.0 Use of the Content Carestream Health CR Systems are designed to meet international safety and performance standards.
More informationUser Guide FOR FACE AND BODY SONIC SKIN CLEANSING. Become a Clarisonic Preferred Customer. Four Speeds + Body Setting. Three-Year Warranty
FOR FACE AND BODY User Guide Four Speeds + Body Setting Three-Year Warranty Adjustable T-Timer Charging Cradle Body Brush Head SONIC SKIN CLEANSING Beautiful skin begins with cleaner skin. Cleaner skin
More informationCAR SEAT/ STROLLER INSTRUCTION MANUAL
CAR SEAT/ STROLLER INSTRUCTION MANUAL English PM-0624AB 3/98 Do not use this 4-in-1 System until you read and understand these instructions! IMPORTANT INFORMATION Thank you for selecting this 4-in-1 System
More informationPICCs and Midline Catheters
Patient Education PICCs and Midline Catheters Patient s guide to PICC (peripherally inserted central catheter) and midline catheters What are PICCs and midline catheters used for? Any medicine given over
More informationCoolflo Safe Touch Shower Mixing Valve ST20015CP
Coolflo Safe Touch Shower Mixing Valve ST20015CP Installation and Maintenance Instructions In this procedure document we have endeavoured to make the information as accurate as possible. We cannot accept
More information1-800-862-2731 Administration of Meropenem For Child
1 Drug Name: _Meropenem 1-800-862-2731 Administration of Meropenem For Child Dosage: milligrams every hours over 5 minutes Key Points: FLUSHING: Meropenem Heparin flush 1. Always wash your hands with an
More informationThis kit may void factory warranty please check with manufacturer.
Mfg Company TM Thank you for purchasing a Sinister Manufacturing Company EGR delete kit. Precision manufactured using aircraft quality 304 stainless steel and billet aluminum; this EGR kit is designed
More informationMBSAW. Meat Cutting Band Saw With Meat Grinder Assembly & Operating Instructions
06/2011 MBSAW Meat Cutting Band Saw With Meat Grinder Assembly & Operating Instructions READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT. This manual provides important information on proper
More informationMAINTENANCE & TROUBLESHOOTING
MAINTENANCE & TROUBLESHOOTING This section describes how to: clean the lens replace the projection lamp replace the batteries in the remote use the security lock feature troubleshoot the projector Cleaning
More informationInstruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN1 2015-10. www.sks-online.com www.sks-webshop.com.
Instruction Manual Alfa Laval SB Membrane Sample Valve ESE02963-EN1 2015-10 Original manual Table of contents The information herein is correct at the time of issue but may be subject to change without
More informationIntroduction A JP Drain is a soft tube and container used to drain fluids that build up under the skin after surgery.
JP Drain Introduction A JP Drain is a soft tube and container used to drain fluids that build up under the skin after surgery. This reference summary explains what a JP Drain is and discusses how to take
More informationCS540. Wireless Headset System. User Guide
CS540 Wireless Headset System User Guide Contents Welcome 3 What s in the Box 4 Base and Headset Basics 5 Accessories 6 Customize Your Headset 7 Change Headset Configuration 7 Left Earloop Assembly 7 Headband
More informationUnique DV-ST UltraPure - Manuel: for valve sizes DN8 to DN80 (¼ to 3 )
Instruction Manual Unique DV-ST UltraPure - Manuel: for valve sizes DN8 to DN80 (¼ to 3 ) ESE01752-EN4 2014-02 Original manual Table of contents The information herein is correct at the time of issue
More informationTermination Procedure. FCUPC One Piece Connector
Termination Procedure (3mm/2.4mm/2mm/1.6mm) Issued By: Engineering Dept. Reviewed By: P.N. Approved By: T.M. SENKO Advanced Components, Inc. 225 Cedar Hill Street, Marlboro, MA 01752, USA Toll-free: +1-888-32-SENKO
More informationS9 Series AutoSet & Elite
S9 Series AutoSet & Elite POSITIVE AIRWAY PRESSURE DEVICEs User Guide A 3 2 5 4 1 S9 AutoSet indications for use The S9 AutoSet self-adjusting system is indicated for the treatment of obstructive sleep
More information4.3-inch Back-Up Camera
TM 4.-inch Back-Up Camera Model No.: PKC0BU4 Owner s Manual and Warranty Information Read these instructions completely before using this product. Retain this Owner s Manual for future reference. INTRODUCTION
More informationPart 1: Physiology. Below is a cut-through view of a human head:
The Frenzel Technique, Step-by-Step by Eric Fattah, Copyright 2001 efattah@interchange.ubc.ca This document should be in electronic form at: http://www.ericfattah.com/equalizing.html Feel free to distribute
More informationArctic Leash Instruction Manual Alaskan Products Company LLC.
Retractable Cord Reel for Engine Block Heaters Arctic Leash Instruction Manual Alaskan Products Company LLC. INSTALLATION INSTRUCTIONS This instruction manual is a reference guide for installing and operating
More informationFrequently Asked Questions: REDEFINE ACUTE CARE Skincare for Expression Lines
Frequently Asked Questions: REDEFINE ACUTE CARE Skincare for Expression Lines 1. How does REDEFINE ACUTE CARE work? REDEFINE ACUTE CARE quickly and comfortably smoothes targeted lines and wrinkles using
More informationFASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL
FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL Congratulations on choosing the Fascination 700 HVLP Tanning Pro System! Your system includes the following items: 1 Fascination 700 HVLP Tanning Pro
More informationREARWARD- & FORWARD-FACING USER MANUAL ECE R44 04. GROUP WEIGHT AGE 0+/1 0-18 kg 6m-4y
REARWARD- & FORWARD-FACING USER MANUAL ECE R44 04 GROUP WEIGHT AGE 0+/1 0-18 kg 6m-4y 1 Thank you for choosing BeSafe izi Combi ISOfix. BeSafe has developed this seat with much care, to protect your child
More information#12 Professional Meat Grinders
#12 Professional Meat Grinders MG-203100 (52021040) Manual Instruction Thank you, and congratulations on purchasing the Non-corrosive electric meat grinder. Your grinder comes complete with everything
More informationIMPACT SPRINKLER TROUBLESHOOTING GUIDE
RAIN USE AND OPERATION BIRD IMPACT SPRINKLER TROUBLESHOOTING GUIDE The diagrams below depict typical Rain Bird sprinklers with all available controls. Your particular model may have only some of these
More informationGuidance for home CPAP
Guidance for home CPAP Turnberg Building Respiratory Medicine 0161 206 3158 All Rights Reserved 2013. Document for issue as handout. Unique Identifier: MED52(13). Review date: September 2015 Name: Hospital
More informationROTARY TUMBLER INSTRUCTIONS AND PARTS LIST
ROTARY TUMBLER INSTRUCTIONS AND PARTS LIST Model 3-1.5B Model 45C Model 33B LORTONE 12130 Cyrus Way Mukilteo, WA 98275 (425) 493-1600 SETTING UP YOUR MACHINE For 45C Unit Only (33B & 3-1.5B already assembled)
More informationIndustrial Strength Rocket Launcher
Industrial Strength Rocket Launcher Description: Instructions for the construction of an industrial strength rocket launcher for use with paper rockets. Materials: Schedule 40 PVC piping and bushings from
More informationTable of Contents. REMstar Auto User Manual 1
Table of Contents Symbol Key... 2 Intended Use & Contraindications... 3 Specifications... 4 Warnings & Cautions... 5 System Features... 7 First Time Setup... 8 Installing the Filter... 9 Device Settings...
More informationYour Recovery After a Cesarean Delivery
Your Recovery After a Cesarean Delivery It is normal to have many questions about your care after delivery. Cesarean delivery is surgery and your body needs time to heal and recover for the next 6 weeks,
More informationFLUSHOMETER - TANK SYSTEM
Owner s Service Manual 501-A Series FLUSHOMETER - TANK SYSTEM 501-A Series FLUSHMATE 501-A SERIES (D) (E) (C) 2 3 (B) 1 4 (F) (A) 6 5 List of Components for 501-A Series*: 1. Lower Supply Group w/hose
More informationTEST PROTOCOL. Revised 7/2010 1
APPENDIX G QUALITATIVE FIT TEST PROTOCOL Revised 7/2010 1 RESPIRATOR SELECTION A. The employee shall be allowed to select the most comfortable respirator from an array of various sizes and models. The
More informationTECHNICAL BULLETIN. Meritor WABCO Cab Leveling Valves and Chassis Leveling Valves. How the Cab Leveling and Chassis Leveling Valves Work
Revised 02-00 TECHNICAL BULLETIN Meritor WABCO Cab Leveling Valves and Chassis Leveling Valves This technical bulletin covers both cab and chassis leveling valves manufactured by Meritor WABCO. While the
More informationINSTALLATION MANUAL. Contents JAPANESE ENGLISH GERMAN FRENCH ITALIAN SPANISH. To the installing technician: CEILING BRACKET
Be sure to read this installation manual thoroughly prior to installation. If installation methods or non-standard parts not specified in this installation manual are used, accidents or injury may result.
More informationInstallation Instructions 4508 4508S
SYMPHONY Spread Lavatory Faucet with Speed Connect Drain Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American Standard faucets. Speed Connect
More informationInstructions for Use. Components of the GENOTROPIN PEN 12
Instructions for Use Important Note Please read these instructions completely before using the GENOTROPIN PEN 12. If there is anything you do not understand or cannot do, call the toll-free number listed
More informationROTARY TUMBLER INSTRUCTIONS AND PARTS LIST
ROTARY TUMBLER INSTRUCTIONS AND PARTS LIST Model QT66 Model QT12 Model QT6 LORTONE 12130 Cyrus Way Mukilteo, WA 98275 (425) 493-1600 SETTING UP YOUR MACHINE Install The Barrel Guide: Using the machine
More informationmusical auto mirror day & night light Control Panel Features Mirror Features Front View Mirror Features Rear View B C Remote Receiver C
Control Panel Features A Power, Low/High Volume Switch Note: The dual-mode night light and music can only be activated by pressing the buttons on the remote. A Mirror Features Front View B Dual-Mode Night
More information