Session Five: Modern XLPE Materials for Extruded Energy Cable Systems
|
|
|
- Hilary Bell
- 9 years ago
- Views:
Transcription
1 Session Five: Modern XLPE Materials for Extruded Energy Cable Systems Abstract Hakan Lennartsson Senior Technical Service Manager, Borouge Hong Kong Pte. Ltd. The first medium voltage cables using extruded XLPE materials were manufactured and installed in the late 1960 s. Over the years XLPE materials have become the preferred technology for manufacturing of MV cables. However the development has not been totally without problems. Cables installed in an early stage showed problems with premature field failures. The problems have been thoroughly studied and today there are different solutions to significantly improve reliability and service life expectations. Another fast growing application is manufacturing of extruded cables for high voltage and extra high voltage. High voltage cable designs has to handle significantly higher electrical stress levels compared to medium voltage designs and this has to be addressed by selection of materials and optimization in material handling and cable manufacturing process The paper discusses background, basic material characteristics, and enhanced materials for medium voltage application as well as important considerations for high voltage materials. Polyethylene Polyethylene is long chain hydrocarbon molecules manufactured by the polymerization of ethylene gas. The main chemical elements making up polyethylene is carbon and hydrogen. The elements are combined by covalent chemical bond and the polymer structure has low polarity which gives inherent good electrical characteristics as low electrical losses. Polyethylene is manufactured from petrochemicals as oil/nafta or gas and recently there have also been studies to use biomass as raw material. Polyethylene is a very versatile polymer with a lot of different end applications. Polyethylene is commonly classified based on density and melt flow rate which gives some of the basic characteristics. In wire and cable applications a commonly used reference for polyethylene classification is ASTM D1248. In this specification type refers to the density range and category refers to melt flow range. There are different polymerization processes for manufacturing of polyethylene and these different processes give somewhat different characteristics to the polymer. The high pressure process will manufacture low density polyethylene, LDPE and copolymers as ethylene-ethyl-acrylate, EEA, ethylene-butyl-acrylate, EBA and ethylene- vinyl- acetate, EVA, respectively. The LDPE is the preferred material for XLPE insulation and copolymers as EBA and EEA are used as base resins for bonded conductive screens. EVA may be used as base resin for bonded as well as strippable 1
2 insulation screens, however when used as insulation screen EVA based compounds has a temperature limitation in the curing process. Low pressure processes uses catalyst and these processes are suitable for manufacturing of linear materials as linear low density polyethylene, LLDPE, medium density polyethylene, MDPE and high density polyethylene, HDPE. The robustness of particularly MDPE and HDPE makes these types of materials suitable as jacketing materials of cables. Crosslinking The crosslinking is a chemical reaction where polymer chains are linked together forming a three dimensional network. The link formed between the polyethylene molecules is a covalent chemical bond ant it is practically an irreversible reaction i.e. the polymer can not be molten and formed to a different shape. Polymers containing a three dimensional network is sometimes referred to as thermo-sets, while polymers that can be molten and reshaped are referred to as thermoplastic materials. Crosslinking of low density polyethylene can be performed by different technologies as Peroxide crosslinking Silane crosslinking Irradiation crosslinking Peroxide crosslinking is by far most the common practice for medium voltage (MV) and the only technology applied in high voltage (HV) and extra high voltages (EHV) cable manufacturing. Silane crosslinking is the dominating technology for manufacturing of low voltage XLPE cable. Irradiation crosslinking are mainly used in special applications where the thickness of the polymer layer is relatively thin. Hot set test is the normal test methods used to determine that XLPE insulation is sufficiently cross linked. A specimen is prepared from the insulation and the cross sectional area is determined. The specimen is placed in a heat oven operating at 200 C with a load of 0.20 MPa. Elongation is determined after 15 minutes, then the load is removed and the sample left to recover for 5 minutes. The requirements are maximum 175% elongation with load and a maximum 15% permanent elongation. Energy Cables Electrical cables for medium voltage and high voltage application typically have three polymeric layers making up the cable core. Conductor shield Insulation Insulation shield Medium Voltage cables can have strippable or bonded insulation shield while high voltage always has bonded insulation shield. Another difference between MV and HV cable is the electrical stress that the materials will be subjected to. 2
3 Electrical Stress Detailed considerations about cable design parameters or mathematical calculations on cable designs is far beyond the scope of this presentation and this information as well as equations for calculations can be found in published books or in conference papers. What we need to understand is that the demand on used materials in crease with increasing cable rating. Looking at commercially available cable designs gives an indication on typical stress in different cable designs. Conductor stress ( kv/mm) Core stress at ( kv/mm) Medium Voltage High Voltage Extra High Voltage If we try to translate the typical electrical stress into requirements on material characteristics: It is of greatest importance that the semi conductive shields has a smooth interface with the insulation i.e. smoothness is very important for the conductor shield The XLPE insulation must have minimum contaminants which can enhance electrical stress build up in the insulation; i.e. cleanliness of the insulation need to be carefully controlled The material in different cable designs will experience different demand of performance as electrical stress increases with increasing cable rating. However it needs to be recognized that cable rating only give an indication of the requirements. Other parameters that have significant influence are conductor size and insulation thickness. It is recommended to consider stress in each specific design of HV and EHV cables to gain the best understanding of requirement on materials and cable manufacturing process. Defects in Polymeric Cables Manufacturing of XLPE insulation material as well as semi conductive screen compounds as well as cable manufacturing is industrial processes and it is not possible to have a 100 % control or manufacture zero defects products. The important factor is to exclude the most dangerous size/types of defects and control and minimize acceptable defects. The potential defects in the polymeric part of the cable core refer to any structure that has different characteristics compared to the polyethylene matrix. 3
4 XLPE Manufacturing Wire and cable application is only using a small part of the world wide production of polyethylene. Wire and Cable is estimated to use approximately 2-3 % of the total polyethylene capacity. Manufacturing of XLPE insulation for particularly high voltage and extra high voltage require specially designed and dedicated manufacturing set up. Reactor tubular reactor to minimize risk of metal Additives and adding process Qualified suppliers with defined specifications and statistical incoming control - cleanliness inline check Production line and packing- special design with all material mapped for rapid identification if wearing. Completely closed system filtered air and special packing monitored by cleanliness check. Cleanliness inspection is performed by an automated inspection unit. A tape is produced from the insulation material and it is inspected by laser and CCD camera. The inspection is made on transparent tape and all structures is identified and classified. The observed structures can be further analyzed to determine origin. MV HV EHV Cable rating (kv) >220 Typical electrical stress (kv/mm) Contaminants to be excluded (microns) Contaminants to be controlled (microns) Semi conductive compounds for conductor and insulation shield are designed to have certain conductivity and carbon black is compounded into a base resin to give conductive properties. Carbon black from two different manufacturing processes is used in W&C applications: Acetylene carbon black gives the best technical performance and is a very chemically clean carbon black with gives excellent surface smoothness Selected furnace carbon black quality depends on source and grade At manufacturing of semi conductive compounds the focus is monitor surface smoothness. 4
5 Cable Manufacturing Process At the cable manufacturing process every manufacturing step may include risks of defects to the cable. Material handling risk of introduction of foreign contaminants from the system or from the air. or build up and oxidation with time with increased risk of ambers and oxidized particles Extrusion process - risk of scorch and ambers and Curing and cooling process risk of voids, insufficient cross linking Finalizing mechanical damages Testing and shipment- mechanical damages It is the recommendation that cable manufacturers get to know their manufacturing process and collect all necessary data from the basis of engineering purpose, and not only rely on data from final quality control. Installation It is of the greatest importance that the cables are installed according to best practice and to avoid any damages to the cable system. Mechanical damage to cable jacket due to abrasion, cuts or cracking occurs and often cables are checked for any damages to jacket after installation. There have been move from PVC jacketing to polyethylene jacket, particularly MDPE and HDPE. The latest generation of linear materials has excellent heat deformation properties very good mechanical properties as hardness and abrasion resistance and good crack resistance. Polyethylene has also a significant better resistance to moisture diffusion compared to PVC. Specifications There are a number of international specifications as well as national specifications and end user specifications. IEC specifications are commonly used as the guiding specifications for HV and EHV cable. IEC60840 IEC62067 These specifications covers routine test, sample test as well as type test of the cable system. With the increasing number of HV and EHV cable systems installed the interest in ageing characteristics has increased. This test is referred as pre-qualification test and it is a one year test at 1.7 U 0 with 180 heat cycles up to C followed by lightning impulse test. The test includes testing of a complete cable system with joint and terminations. Particularly joints and terminations have had some problems with failures in HV and EHV systems and it is important to verify compatibility and establish good craftsmanship in installations. 5
6 Track Record XLPE cables have over the years built up an extensive track record and become the totally dominating material for medium voltage cables world wide. There has been some set backs particularly with water treeing of the early generation of cables in USA and Germany. The origin of the problems is now well understood and the problems were solved by cooperation between material suppliers, cable manufacturers and utilities. There are testing protocols that address testing under wet conditions. New type of materials with improver performance have been developed and proven during more then 20 years field service. The manufacturing of HV cables starting during 1980 s was a challenge for material manufacturers, manufacturing equipment suppliers and cable manufacturers. Again it was a joint effort between all involved parties and the result is that most HV cables installed today is extruded XLPE cables. XLPE cables have also entered the EHV area and cable rated up to 525 kv has been manufactured and successfully installed. EHV cables are a growing area and new projects are coming particularly in larger cities. HVDC cables manufactured with XLPE are a growing area and the first projects have been installed for a decade. Future Outlook The worldwide demand for energy is growing and the demand for electricity in particular is growing at a fast rate. International Energy Authority has made predictions of very significant need for investments both in electricity generation and in transmission and distribution networks for they scenario until The demand for electricity is driven by technology development, change in life style as well industrialization in developing countries. Very many people are today depending on a secure and reliable supply of electricity both when they are working as well as they are spending time at home. Unfortunately there has been as couple of black outs around the world, which has created a lot of concern as well as huge economical losses. There has also been reported a number of occasions where severe weather conditions as typhoons, hurricanes, heavy storm, rain and mudslide or snow has caused loss of power supply. Many countries have not implemented legislation forcing service providers to apply best reliable technical solutions and this has driven underground cables in favor of overhead systems. Material Developments The development work with XLPE compounds are focused on: Improved productivity based on new base resin A continuous curing (CV) line may have different limiting factors: - Material temperature in extruder and risk of scorch - Curing section heat transfer to crosslink insulation outside to inside 6
7 - Cooling section need to be sufficient to cool the cable to avoid voids and partial discharge due to curing by-products Reduced degassing to improve safety and reduce lead time All cables manufactured by peroxide curing will contain by- products from the decomposition of peroxide and curing reaction. The most common by products are Methane, Acetophenone and Cumylalcohol. The by-products may have influence on the cable performance as well as installation. The issues with by-products are: Increased dielectric loss Gas pressure build up o Distortion of metallic foil sheath o Displacement of pre-fabricated as joints and terminations o Safety due to explosion risk with methane Influence PD measurements filling voids or hollow structure Medium voltage XLPE cable is normally sufficient degassed by storage of the cable core in the manufacturing plant before it finalized by adding jacket. The thicker wall thickness of transmission cables and the common use of metallic sheath as moisture barrier/screen in high voltage cable request for a special treatment prior to further processing of the cable core. The degassing treatment is performed at elevated temperature typically in heated chambers at C for 2 to 4 weeks depending on cable size. New solutions for HVDC cables Conclusion Extruded XLPE cables are a very important part of transmission and distribution network all around the world. XLPE materials were developed about 40 years ago and have proven performance from low voltage cables up to extra high voltage cables rated up to 525 kv. However, history has showed that there may be unforeseen difficulties and that basic understanding of the technology as well as ambient operation condition is very essential. The highest standards need to be implemented in material manufacturing, cable manufacturing, and installation and in operation/maintenance to assure reliability as well as cost efficiency. Specifications are in place but these documents can not cover for all occasions, thus it is important to actively monitor performance and take necessary action both in existing operation and for new challenges. 7
KALPANA INDUSTRIES LTD. TECHNICAL DATA SHEET
1 KALPANA INDUSTRIES LTD. TECHNICAL DATA SHEET KI XL - 03 / KI-SC 10 TWO COMPONENT AMBIENT CURABLE POLYETHYLENE COMPOUND FOR INSULATION OF LOW VOLTAGE POWER CABLE DESCRIPTION : KI polyethylene compound
The optimum material solution for Low Voltage energy cables
The optimum material solution for Low Voltage energy cables About Borealis and Borouge Borealis is a leading provider of innovative solutions in the fields of polyolefins, base chemicals and fertilizers.
Visico /Ambicat for cost efficient production of high performance Low Voltage cables
Visico /Ambicat for cost efficient production of high performance Low Voltage cables About Borealis and Borouge Borealis is a leading provider of innovative solutions in the fields of polyolefins, base
KNOW YOUR OPTIONS: 230 KV POWER CABLES
KNOW YOUR OPTIONS: 230 KV POWER CABLES 71 CONDUCTOR MATERIAL AND SIZE Conductor material is a matter of both customer preference and required current carrying capacity At 230 kv, copper is most common
KNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE
Know Your Options: 69 kv XLPE Power Cable 3 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both
Section 5 161 kv Power Cables
Know Your Options: 161 kv Power Cable 61 material and size material is a matter of both customer preference and required current carrying capacity Copper conductor common for larger loads When both copper
LONG-LIFE XLPE INSULATED POWER CABLE
LONG-LIFE XLPE INSULATED POWER CABLE Nigel HAMPTON, NEETRAC, Georgia Tech, USA, [email protected] Rick HARTLEIN, NEETRAC, Georgia Tech, USA, [email protected] Hakan LENNARTSSON,
THE PATHWAY TO POWER HIGH-VOLTAGE CABLES
THE PATHWAY TO POWER HIGH-VOLTAGE CABLES TABLE OF CONTENTS HIGH-VOLTAGE CABLES 3 Advantages of XLPE-insulated cable systems 3 PROPOSAL 4 Cable systems 4 Providing System Solutions 4 Continuous temperature
Wire and Cable Product Guide
Wire and Cable Product Guide Applications Elvax resins with low vinyl acetate content, typically 9 to 15%, are well suited for compounding into primary insulation of UL listed, type XHHW building wire,
UGVCL/SP/591/11KV HT AB CABLE
TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED) 1. SCOPE This specification covers requirements of XLPE insulated, 11 KV Aerial Bunched
HEAT SHRINK RAYCHEM PRODUCT TECHNOLOGY A PROVEN TRACK RECORD OF SOLVING THE WORLD S HARSHEST CHALLENGES
ENERGY /// HEAT SHRINK RAYCHEM PRODUCT TECHNOLOGY HEAT SHRINK RAYCHEM PRODUCT TECHNOLOGY A PROVEN TRACK RECORD OF SOLVING THE WORLD S HARSHEST CHALLENGES For more than 60 years, Raychem products from TE
IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO
IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO WHEN YOU HEAR AN ENGINEER SAY A NUMBER OF DIFFERENT APPROACHES ARE BEING IMPLEMENTED
INTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60502-1 Second edition 2004-04 Power cables with extruded insulation and their accessories for rated voltages from 1 kv (U m = 1,2 kv) up to 30 kv (U m = 36 kv) Part 1: Cables
Stephen G. Whitley, Senior Vice President & Chief Operating Officer
Peter T. Brandien Vice President, System Operations To: Stephen G. Whitley, Senior Vice President & Chief Operating Officer From: Peter T. Brandien Re: Discussion of Cable Technologies Under Evaluation
WIRE AND CABLE ENGINEERING GUIDE
DC Hi Pot Testing Excerpt from PRYSMIAN S WIRE AND CABLE ENGINEERING GUIDE (FOR INFORMATIONAL PURPOSES ONLY) Page 1 of 6 DC HIGH POTENTIAL TESTING DC Hi-Pot testing can be applied as a withstand test (a
WIRE AND CABLE ENGINEERING GUIDE
Excerpt From Prysmian s WIRE AND CABLE ENGINEERING GUIDE Page 1 of 8 CABLE TESTING Testing represents an integral part in the life of a cable. A cable will be subjected to multiple tests in its lifetime
Chlorinated polyethylene ELASLEN TM. Application for Wire and Cable
Chlorinated polyethylene ELASLEN TM Application for Wire and Cable 1 About the company Company Name : SHOWA DENKO K.K. Type of Industry : Diversified Chemical Company Formed : June 1, 1939 Employee : 10,577
SUITABILITY OF DIFFERENT TEST VOLTAGES FOR ON-SITE TESTING OF XLPE CABLE SYSTEMS
SUITABILITY OF DIFFERENT TEST VOLTAGES FOR ON-SITE TESTING OF XLPE CABLE SYSTEMS Michael Hensel HIGHVOLT Prüftechnik Dresden GmbH 2 3 Content 1 Introduction Test parameters and their significance Differences
Polyolefin Heat Shrink Tubing for Tight-Tolerance Medical Applications
Polyolefin Heat Shrink Tubing for Tight-Tolerance Medical Applications Understanding the Advantages and Development Process By Apur Lathiya Vice President and General Manager, Vesta Thermoplastics Division
Borlink Copolymer insulation. ensuring the reliability of medium voltage distribution cable systems
Borlink Copolymer insulation ensuring the reliability of medium voltage distribution cable systems About Borealis and Borouge Borealis is a leading provider of innovative solutions in the fields of polyolefins,
Contact Hueson Corporation for additional information or details. http://www.huesonwire.com 38 Sutton Street Northbridge, MA 01534 508-234-6372
Hueson Corporation of Northbridge MA, a specialty wire and cable manufacturer has recently introduced a solution to a long term industry challenge in the Trailer Cable Industry. Their solution involves
Environmental Stress Crack Resistance Of Polyethylene
Introduction to Environmental Stress Cracking and ESCR Over the past decade, high-density polyethylene (HDPE) materials have improved significantly and now meet more stringent performance standards; some
The new 525 kv extruded HVDC cable system
The new 525 kv extruded HVDC cable system World s most powerful extruded cable system Anders Gustafsson, Markus Saltzer, Andreas Farkas, Hossein Ghorbani, Tobias Quist, Marc Jeroense High Voltage Cables
B1-105. Session 2004 CIGRÉ. Development of high-stress XLPE cable system. D.H. Cho *, D.S. Ahn, J.S. Yang, S.I. Jeon, LG Cable Ltd.
21, rue d'artois, F-75008 Paris http://www.cigre.org B1-105 Session 2004 CIGRÉ Development of high-stress XLPE cable system D.H. Cho *, D.S. Ahn, J.S. Yang, S.I. Jeon, S.K. Kim, W.K. Park, S.C. Hwang LG
SCHEDULE ' A' TECHNICAL SPECIFICATION FOR 11/22/33KV H.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO.
SCHEDULE ' A' TECHNICAL SPECIFICATION FOR 11/22/33KV H.T.XLPE POWER CABLE FOR DISTRIBUTION NETWORK IN MAHARASHTRA (SPECIFICATION NO.MM/I/HTXLPE/2006) MAHARASHTRA STATE ELECTRICITY DISTRIBUTION CO.LTD.
Fault location on power cables. Fault location on power cables
Fault location on power cables Fault location on power cables Contents: 1. Introduction 2. Construction of power cables 3. Cable faults 01. Introduction Fault location on communication and power cables
AORC Technical meeting 2014
http : //www.cigre.org B1-196 AORC Technical meeting 214 Evaluation of Insulating Materials for HVDC Transmission Cable using Space Charge Measurement Y. TANAKA Tokyo City University Japan SUMMARY Some
Elements of Addition Polymerization. Branching and Tacticity. The Effect of Crystallinity on Properties
Topics to be Covered Elements of Addition Polymerization Branching and Tacticity The Effect of Crystallinity on Properties Chapters 1 & 2 in CD (Polymer Science and Engineering) What Are Polyolefins? The
R=Required by Lab S=May be subcontracted IEC SYSTEM FOR CONFORMITY TESTING AND CERTIFICATION OF ELECTRICAL EQUIPMENT COMMITTEE OF TESTING LABORATORIES
IEC SYSTEM FO CONFOMITY TESTING AND CETIFICATION OF ELECTICAL EQUIPMENT COMMITTEE OF TESTING LABOATOIES TESTING AND MEASUING EQUIPMENT/ALLOWED SUBCONTACTING Power cables with extruded insulation and their
W-2. Stranding Comparison
Wire Knowledge W-1 W-2 Stranding Comparison Conductor Coatings/Coverings PURPOSE To facilitate stripping of components applied over the conductor To prevent compound fall-in Improve solderability Prevent
3.6/6 kv XLPE insulated cables 5. 6/10 kv XLPE insulated cables 15. 8.7/15 kv XLPE insulated cables 25. 12/20 kv XLPE insulated cables 35
CONTENTS INTRODUCTION 1 Cable selection, cable specification, cable services CABLES Constructional data: 3.6/6 kv XLPE insulated cables 5 SECTION 1 6/10 kv XLPE insulated cables 15 SECTION 2 8.7/15 kv
Benefits of Thermax N990 in EPDM Compounds
TECHNICAL BULLETIN EPDM Compounds Thermax medium thermal carbon black N990 is manufactured by the thermal decomposition of natural gas. The thermal process provides a unique carbon black characterized
APPLICATION ORIENTED DESIGN OF CABLES
APPLICATION ORIENTED DESIGN OF CABLES Mrs. Rohini Bhattacharyya, Dubai cables Ltd.P. O. Box 11529,Dubai. [email protected] Mr. Nawaf Ahmad Al Mohaideb Dubai Cables Ltd. P. O. Box 11529, Dubai. [email protected]
EVA Modification, Wire Coating
TAFMER TM DF & M Ethylene based α-olefin copolymers TAFMER DF & M is used as a modifier of Ethylene Vinyl Acetate (EVA), Polyethylene (PE) and other thermoplastics to improve its properties. It is suitable
Naue GmbH&Co.KG. Quality Control and. Quality Assurance. Manual. For Geomembranes
Naue GmbH&Co.KG Quality Control and Quality Assurance Manual For Geomembranes July 2004 V.O TABLE OF CONTENTS 1. Introduction 2. Quality Assurance and Control 2.1 General 2.2 Quality management acc. to
THE ELEMENT C. Introduction graphite and carbon Lattice Classification of grain size. Properties of graphite and carbon
THE ELEMENT C Introduction graphite and carbon Lattice Classification of grain size Fine-grained graphite Coarse-grained graphite Properties of graphite and carbon High temperature properties Introduction
Resistance of Plastics to Gamma Irradiation
Elastomers 1 MATERIAL TOLERANCE LEVEL (kgy) COMMENTS Butyl 50 Sheds particulate after irradiation. Ethylene Propylene 100 200 Crosslinks, yellows slightly. Diene Monomer (EPDM) Fluoro Elastomer 50 Avoid
How To Test For Safety On A Power Cable
T H E M A G A Z I N E O F 7 x 2 4 E X C H A N G E I N T E R N AT I O N A L A Green Approach to Building a Superior Data Center S P R I N G 0 9 BUILD FOR TODAY. EXPAND ON DEMAND. Modularity in the data
2 8 k V, 1 / C, T R X L P E I N S U L A T E D, F L A T S T R A P S H I E L D E D C A B L E, C O M P R E S S E D S T R A N D I N G
Seattle Cit y Light 1 of 4 2 8 k V, 1 / C, T R X L P E I N S U L A T E D, F L A T S T R A P S H I E L D E D C A B L E, C O M P R E S S E D S T R A N D I N G 1. Scope This standard covers the detailed requirements
CABLE 101. The Basics of Wire & Cable. Copyright 2007, Belden Inc.
CABLE 101 The Basics of Wire & Cable Copyright 2007, Belden Inc. KEY TERMS Insulations Jacket Capacitance Attenuation Velocity of propagation Dielectric strength Dielectric constant Working voltage Elongation
Welding of Plastics. Amit Mukund Joshi. (B.E Mechanical, A.M.I.Prod.E)
Welding of Plastics Amit Mukund Joshi (B.E Mechanical, A.M.I.Prod.E) Introduction Mechanical fasteners, adhesives, and welding processes can all be employed to form joints between engineering plastics.
HIGH- AND EXTRA-HIGH-VOLTAGE GLOBAL CABLE SYSTEM SOLUTIONS Rely On Our Experience... Experience Our Capabilities
HIGH- AND EXTRA-HIGH-VOLTAGE GLOBAL CABLE SYSTEM SOLUTIONS Rely On Our Experience... Experience Our Capabilities RELY ON OUR EXPERIENCE... EXPERIENCE OUR CAPABILITIES For close to half a century, Silec
Integrated Development and Assessment of New Thermoplastic High Voltage Power Cable Systems
21, rue d Artois, F-75008 PARIS B1-215 CIGRE 2012 http : //www.cigre.org Integrated Development and Assessment of New Thermoplastic High Voltage Power Cable Systems Mike FAIRHURST (1), Ankit GOWADIA (1),
MaxCell Technical Manual Design Parameters
MaxCell Technical Manual Design Parameters Breaking Strength by Product Style, lbs Product Style Standard MaxCell Fire Resistant MaxCell Test Method 4 Cell 2,750 2,200 ASTM D 5 Bellcore 5 5.. Cell 2,50
Basic Properties and Application of Auto Enamels
Basic Properties and Application of Auto Enamels Composition of Ceramic Automotive Glass Enamels Ceramic automotive glass colours are glass enamels that fire on to the glass during the bending process
CHARACTERIZATION OF POLYMERS BY TMA. W.J. Sichina, National Marketing Manager
PERKIN ELMER Polymers technical note CHARACTERIZATION OF POLYMERS BY W.J. Sichina, National Marketing Manager Thermomechanical analysis () is one of the important characterization techniques in the field
PRODUCT / APPLICATION INFORMATION
Abstract This paper will discuss performance life testing and stability testing used for self-regulating heating cables. It will show how the techniques were developed and evolved from the 970 s to the
Figure 1: a) Examples of electrical treeing in polyethylene from a thin tungsten wire. b) Surface discharges from a brass electrode emitting light.
Tittel: Delutladninger og elektrisk trevekst i elektriske isolermaterialer for undervanns installasjoner Title (eng): Degradation of Subsea Electrical Insulation Materials by Partial Discharges and Electrical
Electron Beam Technology for Pressure Sensitive Adhesive Applications
Electron Beam Technology for Pressure Sensitive Adhesive Applications Introduction Stephen C. Lapin, Ph.D. PCT Engineered Systems LLC Davenport, IA, USA Initial reports on the use of ultraviolet (UV) and
Adhesive Bonding of Natural Stone
Adhesive Bonding of Natural Stone Section I: Basics of Stone Adhesion Adhesive Theory There are many theories concerning the forces that are at work in forming an adhesive bond between two (2) different
Hook-Up and Lead Wire
3.1 Hook-Up and Lead Wire 3 Table of Contents Hook-Up & Lead Wire Page Introduction: UL Style & CSA Type Listings 3.2 PVC 3.3 3.8 300V, 80 C 3.3 300V, 105 C 3.4 600V, 105 C 3.5 (Type MW) MIL-W-76C-PVC:
Cable Condition Monitoring to Improve Reliability
Cable Condition Monitoring to Improve Reliability by Hilary Marazzato, Ken Barber, Mark Jansen, and Graeme Barnewall Olex Australia Page 1-1 - Cable Condition Monitoring of Improve Reliability Hilary Marazzato,
Classification of Chemical Substances
Classification of Chemical Substances INTRODUCTION: Depending on the kind of bonding present in a chemical substance, the substance may be called ionic, molecular or metallic. In a solid ionic compound
Plastics and Polymer Business. Properties enhancement for Plastics
News Letter Vol. 18, issue October-December, 2012 Hyperdispersants and Coupling Agents for Thermoplastics and Thermosets Solplus, Ircolplus and Solsperse hyperdispersants and coupling agents have been
B1-102. EHV XLPE CABLE SYSTEMS UP TO 400 kv - MORE THAN 10 YEARS FIELD EXPERIENCE
21, rue d'artois, F-75008 Paris http://www.cigre.org B1-102 Session 2004 CIGRÉ EHV XLPE CABLE SYSTEMS UP TO 400 kv - MORE THAN 10 YEARS FIELD EXPERIENCE W.G. Weissenberg U. Rengel R. Scherer Brugg Kabel
Environmental Stress Crack Resistance of Polyethylene Pipe Materials
Environmental Stress Crack Resistance of Polyethylene Pipe Materials ROBERT B. TAMPA, Product Development and Service Engineer* Abstract Slow crack growth is a phenomenon that can occur in most plastics.
A quick product finder for commercial applications JUDD WIRE INC. A member of the Sumitomo Electric Industries group of companies
A quick product finder for commercial applications JUDD WIRE INC. A member of the Sumitomo Electric Industries group of companies Select, Customize, Order & Receive Products with Ease This catalog contains
INJECTION MOLDING PROCESSING GUIDE Polymer
FOAMAZOL Chemical Foaming Agents INJECTION MOLDING PROCESSING GUIDE Polymer Foaming Agent INJECTION MOLDING WITH CHEMICAL FOAMING AGENTS Introduction The injection molding of structural foam molded parts
T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A
T A B L E T 1 1 of 7 Tests & Inspection Cable PCUT & PCUT-A (Table T1) T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A No. Test Scale MOC Requirements G 20:10:001:01 Defined Test
Cable Selection for Medium Voltage Capacitor Banks and Harmonic Filter Banks
Cable Selection for Medium Voltage Capacitor Banks and Harmonic Filter Banks Introduction This document presents the fundamental aspects of cable and conductor selection for connecting pad mounted shunt
MiCAFIL. 1 RIP Technology. Bushings. Z. Zic 09/2003
MiCAFIL 1 RIP Technology Z. Zic 09/2003 )XQFWLRQRI+LJK9ROWDJH%XVKLQJ Uncontrolled (natural) electrical field Capacity-controlled electrical field %XVKLQJV0DLQ,QVXODWLRQ6\VWHPV 7\SH 0DLQ,QVXODWLRQ +RXVLQJFRYHU
FLEXIBLE CIRCUITS MANUFACTURING
IPC-DVD-37 FLEXIBLE CIRCUITS MANUFACTURING Below is a copy of the narration for DVD-37. The contents of this script were developed by a review group of industry experts and were based on the best available
CONTENTS. ZVU Engineering a.s., Member of ZVU Group, WASTE HEAT BOILERS Page 2
WASTE HEAT BOILERS CONTENTS 1 INTRODUCTION... 3 2 CONCEPTION OF WASTE HEAT BOILERS... 4 2.1 Complex Solution...4 2.2 Kind of Heat Exchange...5 2.3 Heat Recovery Units and Their Usage...5 2.4 Materials
Electrical Maintenance Workshop
Electrical Maintenance Workshop Transformer Maintenance & Testing Thursday, November 6, 2003 Transformer Maintenance & Testing Purpose This presentation provides an overview of the major considerations
Sub sea Cable Technology
EERA DeepWind 2014 Sub sea Cable Technology Hallvard Faremo SINTEF Energy Research Brief presentation of: Wind Farm Cable R&D project Technology for a better society 1 High Voltage Subsea Cables Networking
Good Boards = Results
Section 2: Printed Circuit Board Fabrication & Solderability Good Boards = Results Board fabrication is one aspect of the electronics production industry that SMT assembly engineers often know little about.
)454, !,5-).)5- #!",% 3(%!4(3 #/.3425#4)/. ).34!,,!4)/.!.$ 02/4%#4)/. /& #!",%3!.$ /4(%2 %,%-%.43 /& /543)$% 0,!.43. )454 Recommendation,
INTERNATIONAL TELECOMMUNICATION UNION )454, TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU #/.3425#4)/. ).34!,,!4)/.!.$ 02/4%#4)/. /& #!",%3!.$ /4(%2 %,%-%.43 /& /543)$% 0,!.43!,5-).)5- #!",% 3(%!4(3
MEDIUM VOLTAGE POWER CABLES
MEDIUM VOLTAGE POWER CABLES CONTENTS 1 GENERAL INTRODUCTION 4 TECHNICAL INFORMATION 15 25 35 45 Single Core XLPE Insulated PVC Sheathed Cables UNARMOURED CABLES COPPER UNARMOURED CABLES ALUMINUM ALUMINUM
Poly Processing Company
Poly Processing Company Team Innovation Understanding Environmental Stress Crack Resistance (ESCR) in Rotomolded Polyethylene Tanks Raed Al-Zubi, Ph.D. National Innovation Specialist, Poly Processing Company
High Voltage Systems. Today. The history of cables
High Voltage Cables High Voltage Systems Today Prysmian Cables and Systems B.V. is part of the Prysmian Group, a leading player in the industry of high-technology cables and systems for energy and telecommunications,
Insulation Resistance Testing of Low Voltage Cables in the Field
Insulation Resistance Testing of Low Voltage Cables in the Field Table of Contents 1. Background...3 1.1. Before Making Measurements...3 1.2. How to Apply the Temperature Correction Factor...4 1.2.1. Calculation...4
All Wires and Cables Are Not Created Equal
All Wires and Cables Are Not Created Equal When comparing life cycle costs for wires and cables in wind systems, consider the specific applications, cost per failure and dielectric losses to determine
SPACE CHARGE ACCUMULATION UNDER THE EFFECTS OF TEMPERATURE GRADIENT ON SOLID DIELECTRIC DC CABLE
ISBN 978--658-9 Proceedings of the 6 th International Symposium on High Voltage Engineering Copyright c 9 SAIEE, Innes House, Johannesburg SPACE CHARGE ACCUMULATION UNDER THE EFFECTS OF TEMPERATURE GRADIENT
The original heating cable just got better
The making of the DEVIflex heating cable IEC 60800:2009 approved PVC outer sheath Install down to -5 C Round construction 360 full screening The original heating cable just got better DEVIflex Strong.
Uniprise Solutions COAX 101. White Paper. www.commscope.com
Uniprise Solutions COAX 101 White Paper www.commscope.com Structured cable systems have very thorough standards for fiber optic and twisted pair installations. The cabling components and installed systems
International Electrotechnical Commission Standards
International Electrotechnical Commission Standards Standard IEC 60028 IEC 60038 IEC 60050-461 IEC 60055-1 IEC 60055-2 IEC 60092-101 IEC 60092-350 IEC 60092-351 IEC 60092-352 IEC 60092-353 IEC 60092-354
B05: Cable protection and sheathing
SHEATHING MATERIALS MDPE, BLACK This is the standard sheathing material for cables for outdoor use. The material is UV stabilised with using 2.5 ± 0.5 % carbon black. It has excellent weathering resistance.
the quality par excellence Meghna Industries Manufacturer of : All types of fiberglass Cables
the quality par excellence Meghna Industries Manufacturer of : All types of fiberglass Cables ABOUT US Since our beginning in 1995, We - MEGHNA INDUSTRIES have been one of the fastest growing manufacturer
EVALUATION OF ON-SITE DIELECTRIC RESPONSE METHODS FOR NON- DESTRUCTIVE TESTING OF WATER TREED MV XLPE CABLES
EVALUATION OF ON-SITE DIELECTRIC RESPONSE METHODS FOR NON- DESTRUCTIVE TESTING OF WATER TREED MV XLPE CABLES Sverre Hvidsten*, Peter Werelius**, Jørgen Christensen*** * SINTEF Energy Research (SEfAS),
General Guidelines for Butt, Saddle, and Socket Fusion of Unlike Polyethylene Pipes and Fittings TN-13/2007
General Guidelines for Butt, Saddle, and Socket Fusion of Unlike Polyethylene Pipes and Fittings TN-13/2007 105 Decker Court, Suite 825, Irving, TX 75062 P: 469-499-1044 F: 469-499-1063 www.plasticpipe.org
CABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY
CABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY One Company Connecting The World POWERFUL PRESENCE PRODUCTS PERFORMANCE PEOPLE General Cable has been a wire and cable innovator for
Cable Failure, Diagnostics and. Steven Boggs
Cable Failure, Diagnostics and Rejuvenation Steven Boggs The History PE Cables The Zeigler catalyst was invented in 1953 and mass production of HDPE started in the late 1950 s. Chemically cross linked
Welcome to the October edition of the Nexans Technical Review In this issue we will discuss the following topics:
N E X A N S T E C H N I C A L R E V I E W O C T O B E R 2 0 0 4 Table of Contents Welcome to the October edition of the Nexans Technical Review In this issue we will discuss the following topics: 1. Data
Injection molding equipment
Injection Molding Process Injection molding equipment Classification of injection molding machines 1. The injection molding machine processing ability style clamping force(kn) theoretical injection volume(cm3)
HOW GOOD ARE ELECTRICAL DIAGNOSTIC TESTS TO PREDICT WATER TREES IN HV CABLES AN EVALUATION USING OPTICAL MICROSCOPY
Journal of ELECTRICAL ENGINEERING, VOL. 56, NO. 1-2, 25, 31 35 HOW GOOD ARE ELECTRICAL DIAGNOSTIC TESTS TO PREDICT WATER TREES IN HV CABLES AN EVALUATION USING OPTICAL MICROSCOPY Motaheruddin Ahmed Mohammad
Effect of Sterilization Techniques on Polymers
Effect of Sterilization Techniques on Polymers Contents of Presentation Introduction to Polymers Properties and Stability of Polymers Affect of Ionising Radiation and Ethylene Oxide on Polymers The need
ACCESSORIES FOR HV CABLES WITH EXTRUDED INSULATION
ACCESSORIES FOR HV CABLES WITH EXTRUDED INSULATION Ref: WG 21.06 (TB 177) JTF 21.15 (TB 210) TF B1.10 (Electra 212) Henk Geene Presentation overview Accessories function Accessory design Accessory types
CHEMICAL FOAM EXTRUSION PROCESSING GUIDE
FOAMAZOL Chemical Foaming Agents CHEMICAL FOAM EXTRUSION PROCESSING GUIDE Polymer Foaming Agent foam FOAM EXTRUSION USING CHEMICAL FOAMING AGENTS Introduction The basics of foam extrusion consist of mixing
MICRO PLASTICS MOLDED NYLON 6/6 FASTENERS MECHANICAL TEST DATA - UNC - UNF SECTION
MICRO PLASTICS MOLDED NYLON 6/6 FASTENERS MECHANICAL TEST DATA - UNC - UNF Nylon 6/6 meets MIL-M20693B "A" Type 1, LP410A, and ASTM D789-66 Type 1, GDE 2 All test performed per ASTM specifications. Parts
Derakane epoxy vinyl ester resins: The Evolution of Corrosion Resistant FRP
A Brief History on Corrosion Derakane epoxy vinyl ester resins: The Evolution of Corrosion Resistant FRP Corrosion in industrial processes has always threatened pipes, ducting, process equipment, scrubbers
State, trends and evolutions of HV/EHV power cables systems and contributions of SC B1 to their ongoing progress
0611-048-Mep229 12/12/06 6:44 Page 22 State, trends and evolutions of HV/EHV power cables systems and contributions of SC B1 to their ongoing progress Reinhard SCHROTH, Chairman of SC B1 2002-2006 High
The Contractor shall furnish and install all shielded power cable suitable for use on this project.
Section 16122 PRIMARY POWER CABLES PART 1 GENERAL: WORK INCLUDED The Contractor shall furnish and install all shielded power cable suitable for use on this project. RELATED WORK Section 16020: Tests SUBMITTALS
WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12
WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12 87 88 GOOD INDUSTRY PRACTICES 12 WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12.1 BACKGROUND Most roofs in Singapore are constructed using reinforced
Thermoplastic composites
Thermoplastic composites Definition By definition, a thermoplastic is a material based on polymer (macromolecular compound) which can be shaped, in a liquid (viscous) state at a temperature either higher
SORTING PLASTICS FOR RECYCLING INTRODUCTION
SORTING PLASTICS FOR RECYCLING INTRODUCTION Description Students use the difference in densities of polymers and flame tests as a basis for the development of a scheme to separate plastics. Goals for This
Corporate Profile ROYAL. MODERN ROYAL ELECTRIC Ideal Power Solution MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS
Corporate Profile MODERN ROYAL ELECTRIC Ideal Power Solution ROYAL MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS MAJOR STOCKIST >>> CATHODIC PROTECTION CABLES >>> LOW VOLTAGE CABLES >>> MEDIUM
Weld Cracking. An Excerpt from The Fabricators' and Erectors' Guide to Welded Steel Construction. The James F. Lincoln Arc Welding Foundation
Weld Cracking An Excerpt from The Fabricators' and Erectors' Guide to Welded Steel Construction The James F. Lincoln Arc Welding Foundation Weld Cracking Several types of discontinuities may occur in welds
still different technique of assessment.
D E N S I T Y A N A L Y S I S Micromeritics gas pycnometers are being used worldwide to obtain material density measurements. These measurements are necessary in the manufacture of many of today s products.
100% EMI Emission Containment
100% EMI Emission Containment Designed for Longer Service Life Highly Flexible for Easier Handling and Faster Installation Authorized Distributor Industrial VFD Cables Index n Variable Frequency Drive