1 S&C Switch Operators Type PM Outdoor Distribution For Field Retrofit on Manual PMH, PMS, and PME Pad-Mounted Gear SPECIFICATIONS Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet 150 apply. SPECIAL TO THIS PRODUCT: INCLUSIONS: S&C Type PM Switch Operators are available for field retrofit on S&C Manual PMH, PMS, and PME Pad-Mounted Gear. When so installed, Type PM Switch Operators permit power operation of the associated Mini- Rupter Switch in response to an opening or closing signal from a remote location or locally by means of push buttons. These switch operators thereby make it possible to convert from manual operation to power operation, facilitating the development of a fully automated and remotely operated underground distribution system. Type PM Switch Operators listed in the table on page 3 include the following features as standard: An integral motor for power operating the quick-make quick-break mechanism of the Mini-Rupter Switch. Switch operation is achieved in approximately 3 seconds with nominal control voltage. Open-close push buttons for local electrical operation and provisions for local manual operation. Local/remote selector switch which, in the LOCAL position, prevents remote operation while permitting local mechanical and push button operation and, in the REMOTE position, prevents local push button operation while permitting remote operation. A contact is provided to permit remote indication of selector switch position. Auxiliary switches for remote indication of open and closed switch positions. Decoupler to permit operation of switch operator without affecting the position of the switch. Operation counter. An enclosure of heavy gauge steel and a door equipped with the S&C Penta-Latch Mechanism. The door opening is fully gasketed and ventilation openings include filters with backing plates. Storage bracket in switch operator enclosure for holding manual operating handle (furnished with the padmounted gear). Handle permits local manual charging and tripping of the quick-make quick-break mechanism in the event control power is not available. A template for locating mounting holes and hardware for attaching a Type PM Switch Operator to the padmounted gear enclosure. One switch operator on each unit of pad-mounted gear being retrofitted must be equipped to supply control power to all switch operators on that unit. The control power can be derived from a user-supplied 24-volt dc power source, or optionally an S&C Battery Charger with battery packs (suffix -Y6, -Y7, or -Y8 ) can be installed in one of the switch operators on each unit of pad-mounted gear. The optional battery charger requires a 120-volt ac input which is provided either from an external user-supplied power source (suffix -Y6 ) or from an S&C-supplied internal power source (suffix -Y7 or -Y8 ). The internal power source is available only for PMH and PMS models. Alternately, the control power can be derived directly from a user-supplied 120-volt ac power source through the optional ac power supply (suffix -Y5 ). Refer to OPTIONAL FEATURES on page 3. The number of switch operators to use depends on the number of switches to be power operated on the specific unit of pad-mounted gear; refer to How to Order on page 2. Low-voltage compartments for user-supplied and installed RTU, transceiver, etc. are available as a separate item. Refer to LOW-VOLTAGE COMPARTMENTS table on page 5. For availability of remote terminal units (RTUs) and communication devices in the low-voltage compartment, refer to the nearest S&C Sales Office. For PMH models only, wiring to connect each switch operator to a low-voltage compartment (appropriately mounted on the pad-mounted gear) is available as a separate item. Refer to the INTERCONNECTING-CONTROL- WIRING BASE SPACERS table and WIRING HAR NESSES table on pages 4 and 5. Alternatively, for all models the wiring can be provided by the user, see ACCESSORIES on page 6. Switch operator enclosures, low-voltage compartments, and interconnecting-control-wiring base spacers are protected from corrosion by S&C s olive-green Ultradur Finishing System. Supersedes Specification Bulletin dated SPECIFICATION BULLETIN Page 1 of 6

2 S&C Switch Operators Type PM Outdoor Distribution For Field Retrofit on Manual PMH, PMS, and PME Pad-Mounted Gear Conditions of Sale Continued APPLICATION NOTES: The interconnecting-controlwiring base spacers are 6 inches high, compartmented, and through specification of one of the suffixes listed in the WIRING HARNESSES table they are equipped with all the necessary low-voltage wiring to intercon nect each appropriately mounted Type PM Switch Oper ator with a suitable and appropriately mounted low-voltage compartment. The switch operator that is equipped to supply power to all other switch operators on the pad-mounted gear must be mounted adjacent to Compartment 1 on PMH-3 and PMH-5 Models, or on Compartment 2 of all other models. The low-voltage compartment must be mounted adjacent to Compartment 2 on PMH-3 and PMH-5 Models, or Compartment 3 for all other models. On Models where all four switches are to be power operated, the base spacer pro vides for positioning of all interconnecting control wiring in the switch operator that is on Compartment 3. The interconnecting-control-wiring base spacers shield all low-voltage wiring from medium voltage. These control-wiring base spacers can be connected to installed manually operated PMH models only under one of the following conditions: (1) there is adequate installed cable to compensate for the 6-inch increase in height when the control-wiring spacer is installed, (2) suitable cable splices are made, (3) the installed unit includes an optional 6-inch base spacer (suffix -K1, -K7, -K11, or -K17 ) that is removed before installing the interconnect ingcontrol-wiring base spacer, or (4) the installed unit includes an optional 12-inch or greater height base spacer (suffix -K2 through -K4, -K8 through -K10, -K12 through -K14, or -K18 through -K20 ) and that installed spacer is removed and replaced by a spacer 6 inches lower in height. Low-voltage compartments are equipped for field installation of user-supplied and installed RTU, transceiver, and transducers, etc. Power for any user-supplied equipment in the low-voltage compartment must be provided from a user-supplied control-power source. Provisions are provided at the bottom of the enclosure for entry of low-voltage wiring. How to Order 1. Switch Operators for Field Retrofit a. Obtain the catalog number of the desired unit from the table on page 3. b. Add suffix designations (to the catalog number above) to indicate the optional features desired, selected from the table on page 3. c. If applicable, obtain the catalog number of the desired interconnecting-control-wiring base spacer from the table on page 4. Add a suffix designation to this catalog number to indicate the appropriate wiring harness selected from the table on page 5. d. If applicable, obtain the catalog numbers of the desired low-voltage compartment from the table on page 5. e. Obtain the catalog number of the desired accesso ries from the table on page Example The catalog numbers for one Type PM Switch Operator with optional battery charger and battery packs and with internal control power, plus a second Type PM Switch Operator (which can derive power from the battery pack in the first switch operator), for field ret rofit on a 14.4-kV S&C Model PMH-9 (with two switches to be power operated), are 38971R3-A1Y7 and 38971R3-A1, respectively. The catalog number of the appropriate interconnecting-control-wiring base spacer with wiring harness is CPA W SPECIFICATION BULLETIN Page 2 of 6

3 SWITCH OPERATOR1 For Field Retrofit Applicable to S&C Pad-Mounted Gear Type Catalog Number2 Type PM Switch Operator PMH, PMS, and PME R3-A1 1 One switch operator on each unit of pad-mounted gear to be retrofit ted must be equipped to supply control power to all switch operators on that unit. See page 1 for control power choices. 2 Optional feature -C (key interlock) is required for ultimate users other than electric utilities when the switch operator is to be mounted on gear that includes fuses. 3 For PMS-11, PME-10, and PME-11 Models, dimensional restrictions are such that only one switch operator can be accommodated on each side of the pad-mounted gear (i.e., back-to-back switches cannot both be power operated). 4 For PME models, conduit and fittings between the switch operator and the switch-termination compartment are to be supplied by the user. OPTIONAL FEATURES For Type PM Switch Operators Suffix to be Added to Switch Operator Catalog Number Light Gray Outdoor Ultradur Finish instead of olive green -A2 Stainless-Steel Enclosure Hexhead Actuator for use in lieu of pentahead actuator on Penta-Latch Mechanism Key Interlock locks switch open1 With olive green finish -A10 With light gray finish -A12 When option suffix -A10 or -A12 is not specified -B1 When option suffix -A10 or -A12 is specified -B2 Ac Power Supply for connection to external user-supplied 120-volt ac source2 -Y5 S&C Battery Charger with battery packs3 and with input to the battery charger supplied by Type ZSD Overcurrent Relay mounted in switch operator enclosure, includes three current sensors for conductors of up to 2Z\x-inch diameter per phase5 External control power user-supplied 120-volt ac source -Y6 Internal control power S&C-supplied (voltage sensor with voltage sensor limiter, mounting bracket, and interconnecting wiring) 120-volt ac source.4 For PMH and PMS models only -C 14.4 kv -Y7 25 kv -Y8 24 volt dc6 -Z1 120 volt ac7 -Z2 1 Contact your nearest S&C Sales Office to coordinate interlocking requirements. When ordering to match interlocks on an installed unit, specify key-interlock manufacturer and key number of interlock(s) on the existing pad-mounted gear. When ordering for a new key-interlock scheme, state function of interlock(s) and furnish name of ultimate user, station, and location of gear. 2 For each unit of pad-mounted gear to be retrofitted, order only one switch operator with the ac power supply. All switch operators on a unit of pad-mounted gear can be powered from a single ac power supply, which will be installed in the designated switch operator. 3 For each unit of pad-mounted gear to be retrofitted, order only one switch operator with the battery charger and battery packs. All switch operators on a unit of pad-mounted gear can be powered from a single battery charger with battery packs, which will be installed in the designated switch operator. 4 The S&C Voltage Sensor provides output to drive a 400-milliampere continuous load while recharging a discharged 5 ampere-hour battery within 36 hours. For adequate power to be available, the voltage sensor must be applied at system line-to-line voltages ranging from kv through 17.0 kv for 14.4-kV sensors, and from kv through 29 kv for 25-kV sensors. For field retrofit, the voltage sensor is mounted on a bracket with this assembly shipped loose for mounting by user inside the switch compartment. The S&C Voltage Limiter is factory-installed in the switch operator enclosure. 5 Current sensors must not be installed on unshielded cables or on cables where the insulation is exposed but ungrounded (for example, where dielectric tape or heat-shrink tubing is used). These sensors are intended for application at ground potential and may be damaged by the voltage gradient between the cable insulation and ground. 6 For use when the control-power source for the ZSD relay is the bat tery charger with battery packs or when the control-power source is a usersupplied 24-volt dc source (i.e., suffix -Y5 is not specified). 7 For use when the control-power source for the ZSD relay is to be from a user-supplied external 120-volt ac source and no battery charger with battery packs is specified (i.e., suffix -Y5 is specified). SPECIFICATION BULLETIN Page 3 of 6

4 S&C Switch Operators Type PM Outdoor Distribution For Field Retrofit on Manual PMH, PMS, and PME Pad-Mounted Gear INTERCONNECTING-CONTROL-WIRING BASE SPACERS123 Material No. of Switch Operators to be Mounted on PMG Applicable to Pad-Mounted Gear Models4 Color 14.4-kV Models Catalog Number 25-kV Models Interconnecting-Control-Wiring Base Spacers for mounting directly under pad-mounted gear in conjunction with WIR ING HARNESSES listed on page 5 permit connection of each switch operator to a low-voltage compartment appropriately mounted on the pad-mounted gear56 Mild Steel Stainless Steel 1 PMH-3 PMH-5 PMH-6, -9, -10, 11 2 PMH-6, -9, -10, -11 3, PMH-3 PMH-5 PMH-6, -9, -10, PMH-6, 9, 10, 11 3, Not available for PMS or PME models. 2 For applications including a low-voltage compartment equipped with a remote terminal unit (RTU), contact your nearest S&C Sales Office. 3 One of the suffixes listed in the WIRING HARNESSES table on page 5 must be specified when ordering. 4 The interconnecting-control-wiring base spacers listed in this table are designed for use with PMH models manufactured before April 1992, which are furnished with doors that extend approximately 1 inch over the base of the enclosure. These base spacers will accommodate newer mod els of gear with the flush base design, but the enclosures of these units will extend over the base spacer slightly. If a flush profile is required, a custom base spacer must be ordered. 5 To use these interconnecting-control-wiring base spacers, the Type PM Switch Operator that is equipped to supply power to all other switch Olive green CPA CPA Light gray CPA CPA Olive green CPA CPA Light gray CPA CPA Olive green CPA CPA Light gray CPA CPA Olive green CPA CPA Light gray CPA CPA Olive green CPA CPA Light gray CPA CPA Olive green CPA CPA Light gray CPA CPA Olive green CPA CPA Light gray CPA CPA Olive green CPA CPA Light gray CPA CPA Olive green CPA CPA Light gray CPA CPA Olive green CPA CPA Light gray CPA CPA Olive green CPA CPA Light gray CPA CPA Olive green CPA CPA Light gray CPA CPA operators on the pad-mounted gear must be mounted adjacent to Compartment 1 on PMH-3 and PMH-5 Models, or on Compartment 2 of all other PMH models. Furthermore, the RTU must be in an S&C Low-Voltage Compartment, see table on page 5 (or a suitable user-sup plied equivalent) and that enclosure must be mounted on the right side of Compartment 1 of PMH-3 and PMH-5 Models, or on Compartment 3 of all other PMH models except Models where all four switches are to be power operated. 6 These interconnecting-control-wiring base spacers increase the height of the pad-mounted gear by 6 inches. As a result, installation of interconnecting-control-wiring base spacers requires disassembly of pad-mounted gear from any existing base spacer and may require splicing of installed cable. Refer to APPLICATION NOTES on page SPECIFICATION BULLETIN Page 4 of 6

5 WIRING HARNESSES12 For Interconnecting-Control-Wiring Base Spacers Suffix to be Added to Interconnecting- Control-Wiring Base Spacer Wiring Harnesses installed in interconnecting-control-wiring base spacer includes all necessary wiring for interconnecting switch operators and low-voltage compartment. Also includes wiring between medium-voltage power-operated switch compartments and the low-voltage compartment for con nection of user-installed current sensors, as applicable. For use when power for the switch operators is supplied by 1 One of these wiring harness suffixes must be specified with every interconnecting-control-wiring base spacer. 2 For applications including a low-voltage compartment equipped with a remote terminal unit (RTU), contact your nearest S&C Sales Office. S&C Battery Charger and battery packs with input either from an external user-supplied 120-volt ac source or from an internal S&C-supplied (voltage sensor) 120-volt ac source3 i.e., the switch operator on Compartment 1 or 2 (as applicable) of the pad-mounted gear being retrofitted includes suf fix -Y6, -Y7, or -Y8 S&C Ac Power Supply with input from an external user-supplied 120-volt ac source i.e., the switch operator on Compartment 1 or 2 (as applicable) of the pad-mounted gear being retrofitted includes suffix -Y5 External user-supplied 24-volt dc source i.e., switch operators on the pad-mounted gear being retrofitted do not include suffix -Y5, -Y6, -Y7, or -Y8 -W1 -W2 -W3 3 Voltage sensor and associated interconnection wiring are included with switch operator suffix -Y7 or -Y8. LOW-VOLTAGE COMPARTMENTS12 Material Type of Door Actuator Color Applicable to Pad-Mounted Gear Models Catalog Number Low-Voltage Compartment inside dimen sions in inches: 35M\,H 3 27C\vW 3 11M\,D, includes mounting plate for installation of user-supplied and installed communications equipment (e.g., RTU, transceiver, and transducers). For mounting on pad-mounted gear Mild Steel Stainless Steel 1 For PMS models, a low-voltage compartment cannot be mounted on the same side of the pad-mounted gear as a switch operator. All except CPA Olive green CPA Pentahead All except CPA Light gray CPA All except CPA Olive green CPA Hexhead All except CPA Light gray CPA All except CPA Olive green CPA Pentahead All except CPA Light gray CPA All except CPA Olive green CPA Hexhead All except CPA Light gray CPA For availability of low-voltage compartments equipped with a remote terminal unit (RTU) and communication device, contact your nearest S&C Sales Office. SPECIFICATION BULLETIN Page 5 of 6

6 S&C Switch Operators Type PM Outdoor Distribution For Field Retrofit on Manual PMH, PMS, and PME Pad-Mounted Gear ACCESSORIES Current Sensors, set of three wired split core, rated 600/5 amperes for conductors of up to 3Z\x-inch diameter.12 (Current transducers by user) Applicable to Pad-Mounted Gear Models All models Catalog Number TA-2224 Multiconductor Control-Wire Cable3 For interconnecting a Type PM Switch Operator on Compartment 2 to a Type PM Switch Operator on Compartment 1 (4-compartment units) For interconnecting a Type PM Switch Operator on Compartment 2 to a Type PM Switch Operator on Compartment 4 All models PMH models4 SA SA Pentahead Socket, for Z\x-inch drive Order one set of three current sensors for each three-pole switch. 2 Current sensors must not be installed on unshielded cables or on cables where the insulation is exposed but ungrounded (for example, where dielectric tape or heat-shrink tubing is used). These sensors are intended for application at ground potential and may be damaged by the voltage gradient between the cable insulation and ground. 3 For applications including a low-voltage compartment equipped with a remote terminal unit (RTU), contact your nearest S&C Sales Office. 4 For PMS-11, PME-10, and PME-11 Models, dimensional restrictions are such that only one switch operator can be accommodated on each side of the pad-mounted gear. For these models, Compartments 1 and 2 are the recommended mounting locations SPECIFICATION BULLETIN Page 6 of 6

7

8 Printed in U.S.A.

Specifications. Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet 150 apply. SPECIAL TO THIS PRODUCT:

Specifications. Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet 150 apply. SPECIAL TO THIS PRODUCT: Specifications Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet 150 apply. SPECIAL TO THIS PRODUCT: INCLUSIONS: S&C Switch Operators Type CS-1A are high-speed

More information

Specifications. S&C Manual PME Pad-Mounted Gear Outdoor Distribution (14.4 kv and 25 kv)

Specifications. S&C Manual PME Pad-Mounted Gear Outdoor Distribution (14.4 kv and 25 kv) Outdoor Distribution (14.4 kv and 25 kv) Specifications Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet 150 apply, except as modified under WARRANTY QUALIFICATIONS

More information

Specifications. S&C Power Fuses Types SM and SMLa. For use with SM Refill Units or SMU Fuse Units. Indoor Distribution (4.16 kv through 34.

Specifications. S&C Power Fuses Types SM and SMLa. For use with SM Refill Units or SMU Fuse Units. Indoor Distribution (4.16 kv through 34. S&C Power Fuses s SM and SMLa Indoor Distribution (4.16 through 34. ) For use with SM Refill Units or SMU Fuse Units Specifications Conditions of Sale STANDARD: Seller s standard conditions of sale set

More information

Specifications. S&C Manual Vista Underground Distribution Switchgear Outdoor Distribution (15.5 kv through 38 kv)

Specifications. S&C Manual Vista Underground Distribution Switchgear Outdoor Distribution (15.5 kv through 38 kv) Outdoor Distribution ( kv through kv) Specifications Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet 150 apply. SPECIAL TO THIS PRODUCT: INCLUSIONS: S&C Vista

More information

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations. DIVISION 16 ELECTRICAL SECTION 16100 - ELECTRICAL PART 1 - GENERAL SCOPE All electrical work as shown on the drawings and as necessary to provide a complete electrical system. Include primary service,

More information

CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit

CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit Instructions CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit Catalog Number 2100-SD1 Description The Bulletin 2100 smoke detector unit is a 0.5 space factor unit for use in Bulletin

More information

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Submit shop drawings for equipment provided under this section Shop drawings shall indicate: Section 16435 - SWITCHBOARDS Introduction Part 1 - General Reference The work under this section is subject to requirements of the Contract Documents including the General Conditions, Supplementary Conditions,

More information

SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL 1.1 SUMMARY A. This section describes the requirements for the installation of Power Monitors and associated

More information

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Features: INSTALLATION Install in accordance with NFPA 70. DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short

More information

Section 21. Telecommunication Hardware. www.geindustrial.com BuyLog Catalog 21-1

Section 21. Telecommunication Hardware. www.geindustrial.com BuyLog Catalog 21-1 Introduction...21-1 Fiber Closure Hardware...21-2 Cable Location Surge Protectors...21-4 Introduction GE has been manufacturing Telecommunication Hardware products for over 20 years and has become a leader

More information

Replacement of 600-Ampere Bushing and 200-Ampere Bushing-Well Adapters

Replacement of 600-Ampere Bushing and 200-Ampere Bushing-Well Adapters S&C Vista SD Underground Distribution Switchgear Pad-Mounted and Vault-Mounted Style Outdoor Distribution (17.5 kv and 29 kv) With Visi-Gap Load Interrupter Switches and Visi-Gap Fault Inetrrupters Replacement

More information

TP-C2 Motor Operator CLEAVELAND / PRICE INC. Bulletin DB-111B12

TP-C2 Motor Operator CLEAVELAND / PRICE INC. Bulletin DB-111B12 Bulletin DB-111B12 TP-C2 Motor Operator CLEAVELAND / PRICE INC. 14000 Rt. 993, Trafford, PA 15085 (724) 864-4177 FAX (724) 864-9040 Email: sales@cleavelandprice.com Cleaveland/Price Type TP-C2 Motor Operator

More information

Sample - No Commercial Use

Sample - No Commercial Use COMPLETE REVISION October 2010 Electrical PIP ELSSG01 Design and Fabrication of Low-Voltage Metal-Enclosed AC Power Circuit Breaker Switchgear PURPOSE AND USE OF PROCESS INDUSTRY PRACTICES In an effort

More information

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp and 1250 Amp

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp and 1250 Amp Page 1 2015 Grounded Metal Equipment Plate Equipment Connection Bus Bar or Other Component 15 kv or 25 kv Separable Insulated Connector (elbow) Equipment Connection Power Cable Power Cable Grounded Metal

More information

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132

More information

Advantium 2 Plus Alarm

Advantium 2 Plus Alarm ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia

More information

Display hidden notes to specifier. (Don't know how? Click Here) A. Advanced Upcoiling Security Grilles, power operated.

Display hidden notes to specifier. (Don't know how? Click Here) A. Advanced Upcoiling Security Grilles, power operated. SECTION 08333 ADVANCED UPCOILING SECURITY GRILLE MODEL 600 ADV Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Advanced Upcoiling Security Grilles,

More information

BLUE RIBBON CORP. BC001 Birdcage Installation Manual

BLUE RIBBON CORP. BC001 Birdcage Installation Manual Product Overview: This manual is applicable for the BC001 Birdcage Submersible Level Transmitters. If the product you have has a different prefix part number than listed above please contact the factory

More information

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide Phone: (866) 701-1146 Fax: (425) 216-7558 www.remotecontroltech.com Short Range Wireless Switch System Handheld 8 Installation and Operations Guide Introduction... 2 Before Installation... 2 Receiver Installation...

More information

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions Disabled Toilet Alarm Installation & Operating Contractor Pack Installation & Operating Instructions 1 Overview The Channel Safety Systems Disabled Toilet alarm contractor Packs are an efficient way of

More information

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches PART 1 GENERAL 1.01 Scope Optional Standby Power Generator Systems A. Furnish and install automatic transfer switches

More information

CABINET OPTIONS AND DESIGNATORS

CABINET OPTIONS AND DESIGNATORS CABINET OPTIONS AND DESIGNATORS Hinges: ~Stainless steel lift off Nuts and Bolts: ~ Stainless steel Hardware: ~ Handles and Corbin locks are stainless steel or zinc plated Windows: ~ Lexan Backboards:

More information

GROENEVELD AUTOMATIC GREASING SYSTEMS

GROENEVELD AUTOMATIC GREASING SYSTEMS GROENEVELD AUTOMATIC GREASING SYSTEMS TWIN Parts & Accessories Book Pumps, Fittings, Injectors, Lining, etc. www.groeneveld-group.com 1 TWIN ELECTRICAL Item Part # Description 1 F113966 Switch 24V 2 F122991

More information

Approved Meter Sockets and Cabinets

Approved Meter Sockets and Cabinets Single Unit Residential Guide 1 PHASE, 120/240 VOLT S METERING (Metering sockets and cabinets are supplied by Customer). Outdoor meter mounting height is 1730 mm ( 5 8 ) to center of meter ± 100 mm ( 4

More information

AMP Power Series Connectors

AMP Power Series Connectors May 3, 2011 2011 Tyco Electronics Corporation. All Rights Reserved. TE Connectivity, TE Connectivity (logo) and TE (logo) are trademarks. Other logos, products and/or Company names might be trademarks

More information

SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings

SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings *** Provide this document to the inspector along with ALL system installation instructions *** Project Address: Scope: Standard plan for the installation of grounded microinverter solar PV systems, not

More information

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80 Buck-Boost Transformers Single and Three Phase Potted Buck-Boost Transformers Buck-Boost Applications & Standard Specification... 80 Selecting Buck-Boost Transformers... 81 Single Phase Selection Tables...

More information

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS Replacement parts DO NOT SERVICE THE BOILER WITHOUT A WM97+ MAINTENANCE KIT AVAILABLE Failure to adhere to these guidelines can result in severe personal injury, death or substantial property damage. The

More information

Model SETR-50 and SETR-51 Trim Tab Control

Model SETR-50 and SETR-51 Trim Tab Control Model SETR-50 and SETR-51 Trim Tab Control Pictured above is the SETR-50 with black switches on a gray background. The SETR-51 is identical except for the color, wherein it has black switches on a black

More information

KEY TELEPHONE SYSTEMS RESERVE POWER 47C POWER UNIT

KEY TELEPHONE SYSTEMS RESERVE POWER 47C POWER UNIT BELL SYSTEM PRACTICES AT&TCo Standard SECTION 518-010-107 Issue 1, June 1972 KEY TELEPHONE SYSTEMS RESERVE POWER 47C POWER UNIT 1. GENERAL 1.01 The 47C power unit (Fig. 1) provides emergency power to maintain

More information

Ω POWEROHM RESISTORS, INC. Braking Resistors for Variable Frequency Drives APPLICATION SELECTING A STANDARD DESIGN CUSTOM RATINGS

Ω POWEROHM RESISTORS, INC. Braking Resistors for Variable Frequency Drives APPLICATION SELECTING A STANDARD DESIGN CUSTOM RATINGS Braking Resistors for Variable Frequency Drives APPLICATION AC variable frequency drives are commonly used with a general purpose AC induction motor to form a reliable variable speed drive system. For

More information

Unified requirements for systems with voltages above 1 kv up to 15 kv

Unified requirements for systems with voltages above 1 kv up to 15 kv (1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements apply to

More information

HM-W536 Install Guide

HM-W536 Install Guide HM-W536 Install Guide 9/13/2013 IMPORTANT SAFETY INSTRUCTIONS Warning - When using electrical devices, basic safety precautions should be followed to reduce the risk of fire, electrical shock or injury.

More information

Centro-Matic Automatic Lubrication Systems System Controls

Centro-Matic Automatic Lubrication Systems System Controls Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the

More information

WHOLESALE DIRECT INC. 5620 WEST 65TH STREET

WHOLESALE DIRECT INC. 5620 WEST 65TH STREET Auto Pump V 200 100 0 100 Max Rating Vehicle mount compressor ensures truck air brake system is properly pressurized for immediate dispatch from station Pressure switch regulated operation automatically

More information

73 Chevy C10 Ammeter to Volt Gauge Conversion Mark and Michael Olson 2013 Rev 1.0

73 Chevy C10 Ammeter to Volt Gauge Conversion Mark and Michael Olson 2013 Rev 1.0 73 Chevy C10 Ammeter to Volt Conversion Mark and Michael Olson 2013 Rev 1.0 The ammeter in my son s 73 Chevy C10 did not work, so we decided to convert it to a more modern volt gauge. We made a number

More information

PREFACE. The products covered by this Guide are:

PREFACE. The products covered by this Guide are: PREFACE UL has developed the Molded-Case Circuit Breaker (MCCB) Marking Guide for code authorities, electric utilities, contractors, installers, users, designers, and other interested parties to aid in

More information

CalMod Design-Build Electrification Services

CalMod Design-Build Electrification Services SECTION 28 16 00 INTRUSION DETECTION SYSTEM PART 1 - GENERAL 1.1 DESCRIPTION A. This section describes the detailed technical requirements for the Intrusion Detection System (IDS), where the Contractor

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS LIGHTING CONTROL PANELS 4 AND 8 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.

More information

Electric Motor Operator for: Gate Valves / Butterfly Valves / Plug Valves M&H VALVE

Electric Motor Operator for: Gate Valves / Butterfly Valves / Plug Valves M&H VALVE Electric Motor Operator for: Gate Valves / Butterfly Valves / Plug Valves M&H VALVE Almost every business day, M&H is assembling and testing valves with Electric Motor operators. Electric motor operator

More information

MODEL IX -WAC/HP AIR CONDITIONERS & HEAT PUMPS FOR HIGHLY CORROSIVE & HAZARDOUS AREAS

MODEL IX -WAC/HP AIR CONDITIONERS & HEAT PUMPS FOR HIGHLY CORROSIVE & HAZARDOUS AREAS 1.5, 2, 2.5, 3, 3.5, 4, 5 & 6 Ton Industrial Grade Wall Mounted Air Conditioners & Heat Pumps Unit Application Bebco Model IX-WAC/HP Industrial Grade Air Conditioners & Heat Pumps are designed as a total

More information

Operating Manual. Los Angeles Abrasion Machine HM-70A & HM-70AF

Operating Manual. Los Angeles Abrasion Machine HM-70A & HM-70AF Operating Manual Los Angeles Abrasion Machine HM-70A & HM-70AF Rev: 07/19/2012 PHONE: 800-444-1508 P.O. Box 200, Lewis Center, Ohio 43035-0200 FAX: 800-255-5314 740-548-7298 E-mail: customerservice@gilsonco.com

More information

INTRUSION DETECTION SYSTEM Section 281600

INTRUSION DETECTION SYSTEM Section 281600 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.

More information

Back-Up Camera Installation Guide

Back-Up Camera Installation Guide Hz Hz In This Guide: Back-up camera installation requires connecting power wiring to the existing reverse lighting circuit and adding a chassis ground, as well as routing a video signal cable to the front

More information

Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com

Circuit Breakers. NRC Series. NRC Series. 900 www.idec.com Switches & Pilot Lights Display Lights NRC series circuit breakers offer circuit protection which is far superior to using fuses in applications containing relay circuits, motor circuits, heater circuits,

More information

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1. 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1. 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. 2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. Relays) Part 1 General 1.1 CONDITIONS AND REQUIREMENTS: A. Refer to

More information

SECTION 26 1316 MEDIUM-VOLTAGE FUSIBLE INTERRUPTER SWITCHGEAR

SECTION 26 1316 MEDIUM-VOLTAGE FUSIBLE INTERRUPTER SWITCHGEAR SECTION 26 1316 MEDIUM-VOLTAGE FUSIBLE INTERRUPTER SWITCHGEAR PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and

More information

SPECIFICATIONS FOR THE INSTALLATION OF FIRE ALARM SYSTEMS, SPRINKLER SYSTEMS, AND MASTER BOXES IN THE POQUONNOCK BRIDGE FIRE DISTRICT

SPECIFICATIONS FOR THE INSTALLATION OF FIRE ALARM SYSTEMS, SPRINKLER SYSTEMS, AND MASTER BOXES IN THE POQUONNOCK BRIDGE FIRE DISTRICT SPECIFICATIONS FOR THE INSTALLATION OF FIRE ALARM SYSTEMS, SPRINKLER SYSTEMS, AND MASTER BOXES IN THE POQUONNOCK BRIDGE FIRE DISTRICT The purpose of these specifications is to insure that there are minimum

More information

FIREDEX 2200. Conventional Fire Panels

FIREDEX 2200. Conventional Fire Panels 68 Flexible, high specification system Choice of 1, 2, 4 or 8 zones Simple one-shot auto-reset user test facility Approved to EN54 Maintenance free poly switch circuit protection, with auto reset Class

More information

Specification Guide. for RVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers

Specification Guide. for RVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers Specification Guide for RVAC Direct Replacement AC Medium Voltage Circuit Breakers Table of Contents 1.0 General Work Scope...3 2.0 Standards...3 3.0 Supplier Qualifications...4 4.0 Circuit Breaker Element

More information

261000 Medium Voltage Electrical Distribution

261000 Medium Voltage Electrical Distribution Sections Included In This Standard: 1.1 General 1.2 Underground Cable 1.3 Medium Voltage Switches 1.4 Transformers 1.5 Electrical Manholes 1.6 Switch Vaults 1.7 Distribution Switchgear/Switchboards This

More information

3. TYPES OF SERVICE AVAILABLE. 3.1 Scope

3. TYPES OF SERVICE AVAILABLE. 3.1 Scope 3. TYPES OF SERVICE AVAILABLE 3.1 Scope UI supplies 60 hertz, alternating current with different voltage and ampere ratings. Not all voltage and ampere ratings are available throughout the entire service

More information

MCC Ratings. Voltage Rating

MCC Ratings. Voltage Rating MCC Ratings In addition to the various ratings of individual components used in motor control centers, the overall ratings of the motor control center must also be considered. Voltage Rating Motor control

More information

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS Meher Capacitors offers reliable and innovative products and solutions in the fields of Reactive Power Compensation, Power Quality and Energy

More information

SECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION 08332 COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here) SECTION 08332 COILING COUNTER DOORS Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Coiling Metal Counter Doors. B. Coiling Counter Fire Doors. 1.2

More information

Customer Substation Manual 08/05/02

Customer Substation Manual 08/05/02 Customer Substation Manual Table of Contents Section Page 2 of 85 Description 0 Preface 010.00 General 010.10 Information Required for the Review of New Customer Substations 010.20 New Customer Substation

More information

Recirculating Roof Fans Models ESRMD, ESRMDF and ERD

Recirculating Roof Fans Models ESRMD, ESRMDF and ERD Recirculating Roof Fans Models ESRMD, ESRMDF and ERD Four-Way Fan Exhaust Supply Mix Recirculate BUILDING VALUE IN AIR. October 2005 Recirculating Roof Fans Exhaust/Supply/Recirculation/Mix Model ESRMD

More information

Mobile Data Power Model: MDP-25

Mobile Data Power Model: MDP-25 Mobile Data Power Model: MDP-25 Topic Section Features... 2 Operational Features Summary... 2 Back-up Battery Power Internal Charger Voltage Spike Protection RF Noise Filtering Warning of Imminent Loss

More information

How To Wire Wireline Cable To A Cell Phone (New Zealand)

How To Wire Wireline Cable To A Cell Phone (New Zealand) Installation Guide EnerNOC Site Server - S2 Installation Guide - AUS, NZ v 1.7 EnerNOC New Zealand Limited 2 Collina Terrace PO Box 12-202 Thorndon Wellington NZ 6144 +64 4 909 7546 1 Table of Contents

More information

MidNite Solar E-Panels Explained

MidNite Solar E-Panels Explained MidNite Solar E-Panels Explained A MidNite Solar E-panel is an AC/DC Disconnect Box that has the Inverter installed on the door of the E-Panel or above the E-panel. MidNite's E-Panels place the AC and

More information

CMD-9000 COMMANDER SERIES REMOTE CONTROL ENTRY SYSTEM

CMD-9000 COMMANDER SERIES REMOTE CONTROL ENTRY SYSTEM CMD-9000 COMMANDER SERIES REMOTE CONTROL ENTRY SYSTEM INTRODUCTION Thank you for purchasing the CMD-9000 Commander from Dakota Digital. This, along with many other products that Dakota Digital has to offer,

More information

Dead Tank Outdoor Vacuum Circuit Breaker, Type VOX

Dead Tank Outdoor Vacuum Circuit Breaker, Type VOX Dead Tank Outdoor Vacuum Circuit Breaker, Type VOX Class 6065 Instruction Bulletin 6065-13 11/2011 Retain for future use. Hazard Categories and Special Symbols Read these instructions carefully and look

More information

FAQs-Main switchboard design criteria

FAQs-Main switchboard design criteria FAQs-Main switchboard design criteria Q: What is the Australian standard for main switchboards? Current Australian standard is AS/NZS 3439.1: 2002 originating from IEC 60439. The new series of standard

More information

understanding medium frequency induction melting furnace and its components

understanding medium frequency induction melting furnace and its components understanding medium frequency induction melting furnace and its components 9 Spruce Street, Jersey City, NJ 07306 USA sales@electroheatinduction.com INDUCTION MELTING FURNACE AND ITS COMPONENTS The purpose

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCEC / NASA UFGS-28 31 75.00 10 (November 2008) ----------------------------------- Preparing Activity: USACE Superseding UFGS-28 31 75.00 10 (April 2006) UNIFIED FACILITIES GUIDE SPECIFICATIONS

More information

Dimensions, Inches (mm) No. of Poles Width Height Depth 2, 3 8.25 (210) 16 (407) 5.5 (140) 4 11.125 (283) 16 (407) 5.5 (140)

Dimensions, Inches (mm) No. of Poles Width Height Depth 2, 3 8.25 (210) 16 (407) 5.5 (140) 4 11.125 (283) 16 (407) 5.5 (140) 9-10N Supersedes Selection Data 9-10N, pages, 1-, dated dated March March 1995 1995 Mailed to: E, D, C/9-100A, 31-A, INTERRUPTING CAPACITY RATINGS IEC 947- Interrupting Capacity s➀ Interrupting Capacity

More information

Cooktop Low-Profile Ventilation Hoods

Cooktop Low-Profile Ventilation Hoods INSTALLATION GUIDE Cooktop Low-Profile Ventilation Hoods Contents Wolf Cooktop Low-Profile Ventilation Hoods........ 3 Cooktop Low-Profile Hood Specifications.......... 4 Cooktop Low-Profile Hood Installation............

More information

Maintenance Report MEDIUM VOLTAGE POWER STATION 500SC / 630SC / 800SC / 900SC / 1000 1SC / 1000 2SC / 1250SC / 1600SC / 1800SC / 2000SC

Maintenance Report MEDIUM VOLTAGE POWER STATION 500SC / 630SC / 800SC / 900SC / 1000 1SC / 1000 2SC / 1250SC / 1600SC / 1800SC / 2000SC Maintenance Report MEDIUM VOLTAGE POWER STATION 500SC / 630SC / 800SC / 900SC / 1000 1SC / 1000 2SC / 1250SC / 1600SC / 1800SC / 2000SC Project name: Customer: Address, location of the system: Serial number

More information

White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5

White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5 White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code June 2015 Revision 1.5 Shalhevet Bar-Asher; SolarEdge Technologies, Inc. Bill Brooks, PE; Brooks Engineering LLC

More information

Electrical Systems - IQAN Digital Control System. IQAN Control System Components... 5.1.3

Electrical Systems - IQAN Digital Control System. IQAN Control System Components... 5.1.3 Section 5.1 Electrical Systems - IQAN Digital Control System IQAN Control System Components........................... 5.1.3 IQAN Operational Description: At Machine Startup.....................................

More information

STEALTH I DC MANUAL TECH SUPPORT 1-888-588-4506.WEB www.stealth1charging.com BLACK UNIT IS 24/36 ONLY

STEALTH I DC MANUAL TECH SUPPORT 1-888-588-4506.WEB www.stealth1charging.com BLACK UNIT IS 24/36 ONLY STEALTH I DC MANUAL TECH SUPPORT 1-888-588-4506.WEB www.stealth1charging.com BLACK UNIT IS 24/36 ONLY PLEASE READ AND UNDERSTAND YOUR NEW PRODUCT IMPORTANT MESSAGE: Before installing your newly purchased

More information

B. Related Sections: 1. Section 26 05 33 - Raceway and Boxes for Electrical Systems.

B. Related Sections: 1. Section 26 05 33 - Raceway and Boxes for Electrical Systems. SECTION 262726 - WIRING DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Section includes wall switches; wall dimmers; receptacles; multioutlet assembly; and device plates and decorative box covers. B. Related

More information

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM INSTALLATION MANUAL Protec Fire Detection PLC, Protec House, Churchill Way, Nelson, Lancashire, BB9 6RT. Telephone: +44 (0) 1282 717171 Fax: +44 (0) 1282 717273

More information

Series 8146/5-V37 and Series 8150/5-V37

Series 8146/5-V37 and Series 8150/5-V37 www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection

More information

POWER LOCK KIT GENERAL INSTALLATION -J04427 REV. 2007-12-04. Kit Number. Models. Additional Parts Required. Kit Contents

POWER LOCK KIT GENERAL INSTALLATION -J04427 REV. 2007-12-04. Kit Number. Models. Additional Parts Required. Kit Contents -J0 REV. 00--0 POWER LOCK KIT GENERAL Kit Number -0, 0-0 Models For model fitment information, please see the P&A Retail Catalog or the Parts and Accessories section of www.harleydavidson.com (English

More information

1955-1956 Chevy Bel-Era

1955-1956 Chevy Bel-Era Classic Instruments 1955-1956 Chevy Bel-Era Installation Manual Revised January 2, 2014 Page 1 Table of Contents Table of Contents 2 Welcome to the Team of Classic Instruments! 3 55-56 Chevy Part Identification

More information

Recommended Practice for Installation of Transit Vehicle Fire Protection Systems

Recommended Practice for Installation of Transit Vehicle Fire Protection Systems Recommended Practice for Installation of Transit Vehicle Fire Protection Systems Approved October 25, 2007 APTA Fire Safety Working Group Approved May 3, 2008 APTA Bus Safety Committee Approved October

More information

Distribution Voltage Regulators

Distribution Voltage Regulators Distribution Voltage Regulators Type JFR Single Phase 2.5 to 19.9 kv Type SFR Three Phase 13.2 to 34.5 kv Power Transmission & Distribution Siemens JFR & SFR Voltage Regulators Improving Quality of Service

More information

ZAPPY 3 OWNER S MANUAL. Read this manual completely before riding your Electric ZAPPY 3.

ZAPPY 3 OWNER S MANUAL. Read this manual completely before riding your Electric ZAPPY 3. ZAPPY 3 OWNER S MANUAL Read this manual completely before riding your Electric ZAPPY 3. TECHNICAL INFORMATION Model No. : ZAPPY 3 Product size Type of motor Motor power Battery type Battery Charger Charging

More information

TECHNICAL SPECIFICATION FOR PROJECTION WELDING MACHINE (Qty. 2 Nos.)

TECHNICAL SPECIFICATION FOR PROJECTION WELDING MACHINE (Qty. 2 Nos.) TECHNICAL SPECIFICATION FOR PROJECTION WELDING MACHINE (Qty. 2 Nos.) 1. Requirement: Two (02) Nos. DC Type, 3 phase, 3 wire Projection Welding Machine is required for welding of ventilation M.S. / Stainless

More information

AT&T. PARTNER Plus Door Phone. Installation and Operation Manual

AT&T. PARTNER Plus Door Phone. Installation and Operation Manual AT&T PARTNER Plus Door Phone Installation and Operation Manual Copyright 1990 AT&T All Rights Reserved Printed in U.S.A. CIC# 999-500-317 OII722050-051 Issue 1 October 1990 PARTNER Plus Door Phone is a

More information

Operation and Installation Manual

Operation and Installation Manual Operation and Installation Manual RCM-10 Remote Control Monitor and RSM-10 Remote Status Monitor for the CNA-100 & CNA-200 Automations Revision 1.1 9/98 WARRANTY INFORMATION The RCM-10 Remote Control

More information

Product Guide. Low voltage grounding system. Answers for industry.

Product Guide. Low voltage grounding system. Answers for industry. Product Guide Low voltage grounding system Answers for industry. Advanced switchgear solutions for process industries In today s high-tech manufacturing world, profitability can be greatly impacted by

More information

I Click on a link tab to jump to that page. Cover Page

I Click on a link tab to jump to that page. Cover Page Publication, Duplication, or Retransmission Of This Document Not Expressly Authorized n Writing By The nstall Doctor s Prohibited. Protected By U.S. Copyright Laws. 1997,1998,1999,2000. Factory Radio Other

More information

CutMaster 82. 6.04 Major External Replacement Parts

CutMaster 82. 6.04 Major External Replacement Parts CutMaster 8 6.0 Major External Replacement Parts Item # Qty Description Catalog # Cover with labels 9-08 Base Enclosure Assembly 9-08 Tube, roll handle 9-0 Front Panel 9-07 Rear Panel 9-00 Art # A-080

More information

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling Electronics Ltd Presenting Power, Intelligence... with a sense of feeling By Appointment to Her Majesty The Queen Supplier of Fire Detection Equipment Kentec Electronics Ltd. Dartford Plug in slots K772

More information

SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS

SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS SECTION 26 09 26 LOW VOLTAGE LIGHTING CONTROLS PART 1 - GENERAL 1.01 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements", and Section

More information

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles Clear Glass Sensor Optimum Sensor for Detecting Transparent Glass and Plastic Bottles E3S-CR67/62 Retroreflective Sensor smoothly detects 5-mm gaps. Detects transparent bottles that have a lens effect.

More information

Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms

Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms ABB innovations for changing demands ABB (www.abb.com) is a leader in power and automation technologies that enables utility

More information

8146/5 Series Breaker Panelboards

8146/5 Series Breaker Panelboards 8146/5 Series Breaker Panelboards DISTRIBUTION BREAKER PANELBOARDS FOR HAZARDOUS & CORROSIVE ENVIRONMENTS Breaker Panels Features: Wide variety of Flameproof branch circuit breakers for Zone 1 & Division

More information

AMPSEAL* Automotive Plug Connector and Header Assembly

AMPSEAL* Automotive Plug Connector and Header Assembly AMPSEAL* Automotive Plug Connector and Header Assembly Application Specification 24 SEP 97 Rev E All dimensions are given in millimeters unless otherwise specified. All dimensional tolerances are +0.2

More information

Powers Controls TH 192 S Single Temperature Room Thermostat

Powers Controls TH 192 S Single Temperature Room Thermostat Technical Instructions Document No. 155-065P25 TH 192-1 Powers Controls TH 192 S Single Temperature Room Thermostat 50 60 70 80 TH0355R1 70 80 POWERS Description The TH 192 S thermostats are proportional

More information

VOYAGER 570G. 744A Sprayer Control

VOYAGER 570G. 744A Sprayer Control VOYAGER 570G 744A Sprayer Control U S E R M A N U A L U S E R M A N U A L Table of Contents CHAPTER 1 - INTRODUCTION...1 SYSTEM CONFIGURATIONS...1 KIT CONTENTS...3 CONTROL HOUSING ASSEMBLY...5 CHAPTER

More information

CMD-8000 rev. A COMMANDER SERIES REMOTE CONTROL ENTRY SYSTEM

CMD-8000 rev. A COMMANDER SERIES REMOTE CONTROL ENTRY SYSTEM INTRODUCTION CMD-8000 rev. A COMMANDER SERIES REMOTE CONTROL ENTRY SYSTEM Thank you for purchasing the CMD-8000 Commander from Dakota Digital. This, along with many other products that Dakota Digital has

More information

DirectCommand Installation DirectCommand 3-Channel Spreader Kit

DirectCommand Installation DirectCommand 3-Channel Spreader Kit Note: Indented items indicate parts included in an assembly listed above Part Name/Description Part Number With Switch Box Quantity With Remote Switch Display Cable Kit 4100814 1 1 Power Control Relay

More information

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1 How to configure Part Numbers: Step : Select Switch Amperage Power Module Switch Rating (Amps) Power Module Switch Catalog No. 30 3 60 6 00 200 2 400 4 Step 2: Select Options Needed 5 Bussmann Power Module

More information

FIRE ALARM AND DETECTION SYSTEMS SECTION 16721

FIRE ALARM AND DETECTION SYSTEMS SECTION 16721 PART 1 - GENERAL 1.01 WORK INCLUDED FIRE ALARM AND DETECTION SYSTEMS SECTION 16721 A. Provide a complete fully addressable, power limited, fire detection and evacuation system. The system shall be connected

More information

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS Ducted System RECORD THIS UNIT INFORMATION FOR FUTURE REFERENCE: Model Number: Serial Number: Date Purchased: This manual must be read and

More information

SHIFT INTERLOCK SYSTEM SHIFT INTERLOCK SYSTEM

SHIFT INTERLOCK SYSTEM SHIFT INTERLOCK SYSTEM SHIFT INTERLOCK SYSTEM The shift lock system is designed to ensure the proper operation of the automatic transmission. The driver must depress the brake pedal in order to move the gear selector from Park

More information

TERMINATION ENCLOSURE OPTIONS

TERMINATION ENCLOSURE OPTIONS TERMINATION ENCLOSURE OPTIONS Add suffix: R - Reverse Stagger the Bus Bars (to run cable in from the top) CU - Copper NEMA Mount Bus Bars C - Plastisol Covers for Bus Bars DF - Dead Fronts T - Tin Plated

More information