Air Flow Solutions. Ventilation with Heat Recovery Residential application

Size: px
Start display at page:

Download "Air Flow Solutions. Ventilation with Heat Recovery Residential application"

Transcription

1 ir Flow Solutions Ventilation with Heat Recovery Residential application

2 Ventilation with Heat Recovery Residential The indoor climate is of the utmost importance as most of us spend the greater part of our lives indoors. To ensure comfort and a sense of well-being, the air we breathe should be clean, and also be at the right temperature and humidity level. Whatever the situation, uplexvent Mechanical Ventilation with Heat Recovery solutions can play a significant role as they help create a healthier living environment whilst saving valuable energy. uplexvent asic Line range of compact, entry level mechanical ventilation units with heat recovery designed for social housing, private sector apartment blocks and terraced houses. The units provide high efficiency, low power consumption and low noise balanced ventilation solutions which help meet current uilding Regulations. uplexvent Professional Line range of Passive House Institute certified heat recovery units designed for private and social family houses which combine high performance with premium quality. vailable with unique triple filter and digital control, these units ensure air comfort with advanced control functions such as automatic summer bypass and the heater assisted smart frost protection. uplexvent Interactive Line range of internet enabled, mechanical ventilation units with heat recovery for remote monitoring and control in residential applications. They are designed for comfortable and healthy ventilation in both private and social dwellings such as low energy and passive family houses, flats and high rise apartments. ustomer Services airflow.com

3 uplexvent UNO V Single Room Unit Up to 5 m /hr air volume Key Features Intake air Exhaust air For use in single rooms up to 6 m² * Fully balanced ventilation with simultaneous supply and extract air Easy to install through the wall (no central ducting) Extract filter Supply filter alanced Ventilation Over 9% thermal efficiency Silent operation -8 d() uilt-in electric post-heater Extract air Heat exchanger Supply air utomatic frost protection Technical ata ontrols Three speed digital / wireless control uplexvent UNO V The uplexvent UNO V is a single room heat recovery unit designed to provide balanced ventilation for social and commercial premises plus residential properties. It is ideal for retro-fitting into existing buildings as the unit can be installed easily through the wall that does not involve any central ducting saving on installation time and system cost. Unlike all the other single room heat recovery units on the market, the uplexvent UNO V is equipped with two fans and a plastic counter-flow heat exchanger which deliver balanced supply and extract air ventilation at all times with a heat recovery efficiency exceeding 9%. oost with timer function uilt in G filters with maintenance indicator year warranty + The unit has a metal polymer coated casing finished in a mirror polished stainless steel. The mm synthetic rubber insulation provides sound insulation and avoids thermal bridging. The automatic frost protection prevents condensate freezing in cold periods whereas two G filters clean the indoor air and protect the internal components of the unit. In addition, the built-in post-heater warms the supply air to a comfortable level if needed. Having the low energy E fans the unit consumes as little as 9 watts and comply with the ErP 5 standards. Specification uplexvent UNO V Max. ir Flow m /hr / Pa 5 / Thermal efficiency Over 9% Heat exchanger ounterflow (Plastic) Fans E Frost protection Reducing supply air ontrols -Speed (digital/wireless) Mounting Wall Sound m (d()) - 8 uct diameter (mm) x 5 Electrical supply v / ph / 5Hz Max. power consumption w Filter class x G Electric post-heater 5w Protection class IP asing insulation (mm) Weight (kg) imensions (L x x H) mm 5 x x 58 Part No. 9 The uplexvent UNO V is equipped with a digital display which is located on the front cover plus a wireless controller allowing adjustments from anywhere within the room. Speeds, and produce an air capacity of 6, 5 and 5 m³/hr respectively. dditional functions on the control panel include: Extra heating of supply air Separate fan control oost activation timer adjustable between and 6 minutes Weekly ventilation programming Filter replacement and condensation drain pan level indicator igital controller Wireless controller * Guidance only. ependant upon system pressure. imensions Quick Installation E + excludes motors. Motor warranty one year from date of purchase. Model E UNO V ø5 airflow.com ustomer Services airflow.com

4 uplexvent V7 asic Line Top Entry - Up to 8 m /hr air volume Key Features SP ppendix Q For use in small and medium sized dwellings up to 5 m * Extracts up to 5 m /hr at Pa Over 9% thermal efficiency Thermal summer by-pass Energy efficient E fans ensure low SFP Fits inside a 6mm kitchen cupboard In-built frost protection eiling suspended version available (V7S) Tested by the RE (uilding Research Establishment) and eligible for the SP ppendix Q V7 SFP Efficiency K+ Wet room.6 W/l/s 9% K+ Wet rooms.68 W/l/s 9% K+ Wet rooms.8 W/l/s 89% K+ Wet rooms.99 W/l/s 88% Technical ata ontrols V7 installed in a kitchen cupboard uplexvent V7 Independantly adjustable fans SP-ppendix Q eligible omplies with uilding Regulations year warranty Specification uplexvent V7 uplexvent V7S Max. air flow m /hr / Pa 8 / 78 8 / 78 ir flow m /hr / Pa 5 / 65 5 / 65 Thermal efficiency Over 9% Over 9% Heat exchanger ounterflow (Plastic) ounterflow (Plastic) Fans E E ontrols (normal and boost) -Speed -Speed Mounting Wall eiling Sound m (d()) uct diameter (mm) x 5 x 5 ondensate discharge (mm) x separately mounting commissioning switch is supplied with the unit. Two, % user adjustable speed levels can be set on installation. In addition both fans can be independently adjusted to ensure a balanced system upon commissioning. lso accepts boost function switches (not supplied). n automatic thermal summer by-pass will activate when the supply air temperature reaches 5 to prevent dwelling overheating via heat exchanger. uplexvent V7 is a high performance heat recovery unit which provides a cost-effective solution for residential dwellings. This MVHR unit is equipped with an easily removable polypropylene, ultra-high efficiency heat exchanger which transfers more than 9% of the warmth from the outgoing waste airstream into the incoming fresh air. thermal by-pass helps to avoid dwelling overheating in summer. Thanks to its extremely compact size the uplexvent V7 can be mounted in a standard kitchen cupboard or on the wall vertically which provides a space-saving solution especially for small and medium size dwellings. Our SP ppendix Q eligible V7 and IRFLEX PRO ducting system create a perfect solution with highly efficient heat recovery and Zero Leakage air transfer which provide ventilation levels that meet the latest uilding Regulations (pproved ocument F). Electrical supply v / ph / 5Hz v / ph / 5Hz Max. power consumption 5w 5w Filter class x G x G Thermal by-pass Yes Yes Electric post-heater w (optional) w (optional) Electric frost protection Yes Yes Protection class IPX IPX Weight (kg) imensions (L x H x ) mm 56 x 65 x 6 56 x 65 x 6 Part No imensions Performance Warm ir to Rooms Extract from Wet Rooms Intake from Outside ischarge to tmosphere STTI PRESSURE (Pa) Extract Supply l/sec IR FLOW m /hr ondensation rain * Guidance only. ependant upon system pressure. ccessories Model = EPTH V See switches/accessories for more details. 6 airflow.com ustomer Services airflow.com

5 uplexvent V asic Line Top Entry - Up to 75 m /hr air volume Key Features SP ppendix Q For use in medium and large sized dwellings up to m * ir volume up to 5 m Pa Low energy E fans with.5 W/l/s SFP Over 9% thermal efficiency utomatic summer bypass and frost protection Filter monitoring via pressure sensors Easy installation via interchangeable spigots Tested by the RE (uilding Research Establishment) and eligible for the SP ppendix Q V SFP Efficiency K+ Wet room.9 W/l/s 9% K+ Wet rooms.5 W/l/s 9% K+ Wet rooms.8 W/l/s 9% K+ Wet rooms.5 W/l/s 9% K+5 Wet rooms.59 W/l/s 9% K+6 Wet rooms.69 W/l/s 9% K+7 Wet rooms.8 W/l/s 9% Easy maintenance through the filter access door uplexvent V uplexvent V is one of the latest additions to irflow s uplexvent asic Line which provide balanced ventilation with high efficiency heat recovery, low power consumption and quiet operation to modern residential dwellings. Tamperproof operation for extra safety ata logging capability SP ppendix Q eligible omplies with uilding Regulations year warranty + Equipped with the new generation Radical Range fans, the unit achieves very low SFP levels thus providing house builders and developers with reduction in welling Emission Rates (ER). Technical ata Specification uplexvent V Max. air flow m /hr / Pa 75 / ir flow m /hr / Pa 5 / 8 Thermal efficiency Over 9% Heat exchanger ounterflow (Plastic) Fans E Summer bypass damper utomatic Frost protection Reducing supply air ontrols -Speed + oost Mounting Floor / Wall Sound m (d()) - uct diameter (mm) x 6 ondensate discharge mm Electrical supply v / ph / 5Hz Max. power consumption 8w Filter class x G (F7 optional) Sound urve Sound Pressure Level (d: Overall Scale) d() 6 5 NR5 NR NR NR NR NR entral Frequency (ycle per Second) oost High Speed Medium Speed Low Speed Hz esigned for price-sensitive large-scale projects to help meet current uilding Regulations this MVHR unit also complies with the Energy Saving Trust est Practice. Electric frost heater w (optional) Electric post-heater w (optional) Protection class IP Weight (kg) imensions (L x H x ) mm 7 x 75 x 6 Part No. 9 imensions Performance Front View F M N G Top View Rear H I J K L STTI PRESSURE (Pa) 5 oost High Speed Medium Speed Low Speed E + excludes motors. Motor warranty one year from date of purchase. Front Model E F G H I J K L M N V l/sec m /hr IR FLOW * Guidance only. ependant upon system pressure. ccessories See switches/accessories for more details. 8 airflow.com ustomer Services airflow.com

6 uplexvent V asic Line Top Entry - Up to 75 m /hr air volume Versatile Unit onfiguration V Simple vs igital ontrol Spigot Relocation The unit is supplied as a right handed version as standard. Thanks to the universal condensate drain the unit can easily be changed to the left hand configuration by swapping the front and rear covers. Functions Three speed control (Low - Medium - High) utomatic bypass The uplexvent V has a number of options regarding the position of the four entry/exit spigots. This enables more flexibility when positioning the heat recovery unit and ducting. It is possible to configure the unit for bottom entry connection should space consideration for connecting duct runs necessitate it. E Exhaust air to atmosphere S Supply air to dwelling Removing the front and rear covers S R E O oost with timer Frost protection Frost heater control Spigot O Outdoor air from atmosphere R Return air from dwelling Post-heater control Sealing ap uplexvent V (right handed - standard delivery) uplexvent V (left handed) Indoor temp setting via extract / supply / room temp Separate fan control lanking ap uplexvent V spigot relocation Simple ontrol igital ontrol Weekly ventilation programming Filter Maintenance Indication Simple control incorporates the following features: speed control, low and high speeds are % adjustable via potentiometers, medium speed is calculated automatically. oost function increases air flow when needed. Manual boost with run-on timer / automatic boost with delay timer. hildproof protection locks / unlocks the buttons providing extra safety. Filter maintenance reminder via counter clock (standard) / via pressure sensor (optional). Heater control for frost heater and post-heater. onnection to MS via Modbus RTU (RS85). dvanced digital control also provides: Optional separate fan control for ease of commissioning. Weekly ventilation programming allows users to pre-set the ventilation levels scheduled for different days. ata logging capability keeps record of unit's operation. Optional humidity or air quaility sensors enable automatic boost control. Indoor temperature control based on room, extract or supply air temperature. ata logging Filter maintenance indicator via counter clock Filter maintenance indicator via pressure sensor emand control via humidity/o /PIR sensors Emergency shut-off (in case of fire etc.) Self diagnostic MS connection (MOUS RS85) On the standard V a counter clock is available to alert the user for maintenance at the pre-set time period. lternatively, an additional pressure sensor is used to monitor the real-time filter status. This provides more accurate and cost-efficient maintenance. Self iagnostic. On-demand control via humidity and PIR sensors. uilt-in humidity/air quality sensor Set temperature adjustments Set timer adjustments onstant flow function Filter pressure sensor connected at the bottom of the unit airflow.com ustomer Services airflow.com

7 uplexvent V5// asic Line Side Entry - Up to 5 m /hr air volume Key Features % utomatic ypass Exhaust ir Outdoor ir uplexvent V5// The uplexvent asic Line V5, V and V are highly efficient, side entry mechanical supply and extract ventilation units with heat recovery for an air capacity of up to 5 m /hr. The unit casing is made of high density EPP material which provides significant insulation, eliminates any thermal bridging. For use in small, medium and large sized dwellings up to m * models (side entry) up to m /hr at Pa ompact size (8mm height) provides space saving solutions Over 9% thermal efficiency and low noise utomatic, % summer bypass an be installed on the wall, under the ceiling or on the floor Light weight enables one man installation Simple manual switch as standard. Optional touch screen panel with advanced controls ompliant to ErP 5 standards omplies with uilding Regulations year warranty + The units include an easily removable, plastic heat exchanger which transfers warmth from the outgoing waste airstream into the incoming fresh air where its thermal efficiency exceeds 9%. t no point do the airstreams mix. Having the latest, low energy E fan technology, the V5, V and V comply with the ErP 5 standards and are tested by TUV laboratories. The units are equipped with an automatic, % bypass which totally isolates the heat exchanger so that no air passes through it. This provides effective cooling in the summer season. Technical ata Speciation uplexvent V5 uplexvent V uplexvent V Max. air flow m³/hr / Pa 8 / 78 / 9 5 / 8 ir flow m³/hr / Pa 5 / 69 / 8 / Thermal efficiency Over 9% Over 9% Over 9% Heat exchanger ounterflow (Plastic) ounterflow (Plastic) ounterflow (Plastic) Fans E E E Summer bypass damper % automatic % automatic % automatic Frost protection Reducing supply air Reducing supply air Reducing supply air ontrols Variable Speed ontroller Touch screen panel (optional) Supply ir to the dwelling Variable Speed ontroller Touch screen panel (optional) Extract ir from the dwelling Variable Speed ontroller Touch screen panel (optional) Mounting Wall / eiling / Floor Wall / eiling / Floor Wall / eiling / Floor Sound m (d()) uct diameter (mm) x 6 x 6 x 6 ondensate discharge mm mm mm Electrical supply v / ph / 5Hz v / ph / 5Hz v / ph / 5Hz Max. power consumption w w w Filter class x G (optional F7) x G (optional F7) x G (optional F7) Electric frost heater w (optional) 7w (optional) 7w (optional) Electric post-heater w (optional) 7w (optional) 7w (optional) Protection class IP IP IP Weight (kg) imensions (L x x H) mm 85 x 8 x x 8 x 8 85 x 8 x 8 Part No imensions Performance K K H K M K 6 5 V V5 8 V K K K J K K K K K K E F K G K STTI PRESSURE (Pa) 6 K K l/sec K K. ondensate drain for wall/floor-standing position K. ondensate drain for under ceiling position K. ondensate drain for floor-standing flat position K. ondensate drain for floor-standing flat position L (only one K outlet is connected according to unit orientation) K + excludes motors. Motor warranty one year from date of purchase. I K Model E F G H I J K L M V V/ M m /hr IR FLOW * Guidance only. ependant upon system pressure. ccessories See switches/accessories for more details IR FLOW airflow.com ustomer Services airflow.com K. ondensate drain for floor-standing position K. ondensate drain for underceiling position K. ondensate drain for floor-standing flat position (only one K outlet is connected according to unit orientation)

8 uplexvent V5// asic Line Side Entry - Up to 5 m /hr air volume Mounting Positions Unique to these side entry units is the ability to install the same unit at: Wall / Floor - standing position eiling - flat position (with inclination for drainage) Floor - flat position (with inclination for drainage) This provides exceptional flexibility in product specification, installation and storage. Internet onnection The uplexvent asic Line side entry units can optionally be equipped with a web server that uses Modbus TP/IP protocol to provide a connection between the ventilation unit and the internet via a standard plug and play ethernet cable. This allows you to monitor and control the unit from a computer, laptop or smart phone via the internet or a local area network. The unit can also be monitored remotely by technical service which saves time and cost on service processes. Simple ontrol Simple control incorporates the following features: Variable speed control % adjustable by the user utomatic boost function increases air flow when needed (via volt-free contact or -V sensor output) utomatic frost protection reduces the supply ventilation rate for a certain period to prevent ice build-up within the heat recovery cell depending on the outside air temperature utomatic summer bypass provides free cooling in the summer season. Its motorised damper is triggered by the temperature sensor automatically Heater control for frost heater and post-heater Touch Screen ontrol dditionally, the digital control provides the following features: Stylish Touch Screen with easy-to-use interface Weekly ventilation programming allows users to pre-set the ventilation levels scheduled for different days. Party / Holiday mode to set the air volume for specific time period based on occupancy. Filter Maintenance reminder Indoor temperature control and display based on; Extract air temperature Supply air temperature Heaters The new generation PT (Positive Temperature oefficient) electric heater incorporates a power adjustment facility which automatically increases/decreases the power based on the air volume going through the heater hence shortens the heating response. lso the heater has two protection thermostats and a perforated metal filter which can easily be maintained via the inspection door. This significantly increases its life span especially when the heater is installed on the incoming air side for frost protection purposes. lternatively it can be used as post-heater to achieve the required indoor air temperature. Metal Housing To achieve better sound levels the units can optionally be covered with a metal jacket which is made of galvanised metal sheet. This special accessory also protects the unit from external damage and extends the life span of the unit. airflow.com ustomer Services airflow.com

9 I uplexvent V9SK Professional Line Top Entry - Up to m /hr air volume Key Features SP ppendix Q uplexvent V9SK The uplexvent V9SK is a ventilation unit with stateof-the-art technology, designed to provide both essential ventilation and to save you money through its intelligent, cost effective and eco-friendly heat recovery system. The unit is delivered with a stylish cooker hood which incorporates an integral fire damper providing fire safety between the hood and the MVHR unit. The unit can be integrated into a fitted kitchen design. For use in medium sized dwellings up to 6 m * Extract up to 6 m /hr at Pa Galvanised steel, double skin casing ooker-hood provides separate extraction Triple filter design with F7 pollen filter Over 9% thermal efficiency and low SFP Manual % summer bypass New smart frost protection uilt-in electric post-heater uto cut-out switch for extra safety SP-ppendix Q eligible omplies with uilding Regulations 5 year warranty + It also includes a grease filter which protects the MVHR unit against particles such as cooking oil extracted through the cooker hood. Unlike all other MVHR units with cooker hood on the market, the V9SK recovers heat even when the separate cooker hood extract is in operation. This important feature prevents cold air draughts especially in winter and keeps your house warm at all times. Tested by the RE (uilding Research Establishment) and eligible for the SP ppendix Q V9 SFP Efficiency K+ Wet room.7 W/l/s 8% K+ Wet rooms.7 W/l/s 8% K+ Wet rooms.8 W/l/s 8% K+ Wet rooms.9 W/l/s 8% K+5 Wet rooms.6 W/l/s 8% Technical ata Specification uplexvent V9SK R uplexvent V9SK L Max. air flow m /hr / Pa / 9 / 9 ir flow m /hr / Pa 6 / 85 6 / 85 Thermal efficiency Over 9% Over 9% Heat exchanger ounterflow (Plastic) ounterflow (Plastic) Fans E E Summer bypass damper % automatic % automatic Frost protection Frost heater Frost heater ontrols -Speed - Manual (on cooker hood) -Speed - Manual (on cooker hood) Mounting Wall Wall Sound m (d()) uct diameter (mm) x 5 x 5 ondensate discharge (mm) Electrical supply v / ph / 5Hz v / ph / 5Hz Max. power consumption 8w 8w Filter class x G / x F7 x G / x F7 Electric frost/post-heater 9w 9w Protection class IP IP asing Insulation (mm) Weight (kg) 5 5 imensions (L x x H) mm 597 x 58 x 798 (incl. cooker hood) 597 x 58 x 798 (incl. cooker hood) Part No imensions Performance FRONT PRT OF UNIT SEEN FROM OVE Right side SEEN FROM EHIN Left side J G O H P Q E F N M L K uct outlets, Model R Inner diameter of female outlet collar ø5mm. Supply air to dwelling. Extract air from dwelling to unit. Outdoor air to unit. Exhaust air out uct outlets, Model L Inner diameter of female outlet collar ø5mm. Supply air to dwelling. Extract air from dwelling to unit. Outdoor air to unit. Exhaust air out STTI PRESSURE (Pa) 5 S E8 S8 S7 E7 5 S6 E6 E5, S5, E,5 S,5 5 E S E S l/sec Extract Supply IR FLOW E m /hr + excludes motors. Motor warranty one year from date of purchase. Model E F G H V9SK I J K L M N O P Q * Guidance only. ependant upon system pressure. ccessories See switches/accessories for more details. v 6 airflow.com ustomer Services airflow.com

10 uplexvent V9SK Professional Line Top Entry - Up to m /hr air volume The unit is made of a galvanised steel double-skin casing which is powder coated both internally and externally to meet hygiene requirements. Moreover, the mm thick insulation in the casing avoids any thermal bridging and significantly reduces noise levels. The V9SK includes an easily removable, plastic heat exchanger which transfers warmth from the outgoing waste airstream into the incoming fresh air where its thermal efficiency exceeds 9%. t no point do the airstreams mix. The unit includes the brand new smart frost protection facility which significantly reduces the energy consumed to protect the heat exchanger from freezing (see below for more information). Fitted with an additional electric post-heater, the unit keeps the indoor air temperature at the required temperature level at all times hence saving energy especially during the winter period. The V9SK unit is designed with a unique triple filter facility including a F7 pollen filter which provides additional protection against invisible, harmful particles and creates an ultra hygienic environment, particularly relevant for those suffering from asthma or other respiratory conditions. Having the latest, low energy E fan technology, the V9SK complies with the ErP 5 standards. The unit comes with an outstanding 5 year warranty + and is SP ppendix Q eligible. Triple Filter esign The majority of the MVHR units in the U.K incorporate G or G coarse filters on the extract / supply air side. These filters catch only coarse particles such as insects and leaves to protect the heat exchanger. F7 fine filters on the other hand are highly efficient, catch invisible particles such as pollen, spore, bacterium and dust entering the lungs. uplexvent Professional Line units are the only MVHR units which incorporate triple filter design combining G course filters with the F7 fine filter. This significantly improves the indoor air quality and lowers your maintenance costs. G Filter F7 Filter New Smart Frost Protection % utomatic ypass Exhaust ir Traditional Traditional Frost Frost Protection Protection Logic Logic New New Smart Smart Frost Frost Protection Protection Logic Logic 5 5 Supply Supply ir ir Extract Extract ir ir Supply Supply ir ir Extract Extract ir ir +X +X ca.+ ca.+ +X +X FH FH ca.+ ca.+ ~% ~% % % (efrosting) (efrosting) % % The unit is equipped with an automatic, % bypass which totally isolates the heat exchanger so that no air passes through it. This provides effective cooling in the summer season. ontrols Supply ir to the dwelling Extract ir from the dwelling Outdoor ir ~6% ~6% % % ca. +6 ca. +6 EPH EPH ca. ca. ca. ca. ca. ca. Exhaust Exhaust ir ir ca. ca. Outdoor Outdoor ir ir Exhaust Exhaust ir ir 6 Outdoor ir 6 Outdoor ir Timing Timing and energy and energy consumption consumption graph graph when when Timing Timing and energy and energy consumption consumption graph graph when when frost heater frost heater is used is used electric electric pre-heater pre-heater is usedis used (ca. 5% (ca. less 5% energy less energy consumption) consumption) Time Time Time Time uplexvent Slim-Line ooker Hood olour options of white or grey uplexvent Slim-Line cooker hoods are equipped with a handy sliding glass panel which incorporates a fluorescent lamp. The hoods have detachable grease filters which can be easily maintained. On the traditional frost protection method, the outdoor air is pre-heated before passing through the heat exchanger. This way the unit could still provide balanced ventilation even when the frost protection was on. However, the electric heater kicks in intermittently hence consumes more energy than needed. Supply air fan Exhaust air fan Heat exchanger Electric pre-heater 5 Frost heater 6 Electric bypass damper The new Smart Frost Protection method works in a more energy efficient manner which constantly monitors the heat exchanger conditions and uses the frost heater only when necessary. This significantly reduces the energy consumption and provides more heat recovery throughout the winter season. is adjusted via an integrated four speed switch. Four Speed Switch n alternative to the cooker hood control is the manually operated speed switch which allows simple unit operation when required. Easy to install Manual selection of the fan speed % adjustable speed levels User friendly for quick and simple control. 8 airflow.com ustomer Services airflow.com

11 uplexvent V96SE Professional Line Top Entry - Up to 5 m /hr air volume Key Features SP ppendix Q uplexvent V96SE The uplexvent V96SE is a highly efficient mechanical supply and extract ventilation unit with heat recovery for an air capacity of up to 5 m /hr. It is a wall mounted unit and is delivered complete with a wall mounting plate and condensate drain. The unit is made of a galvanised steel double-skin casing which is powder coated both internally and externally to meet hygiene requirements. For use in medium sized dwellings up to 75 m * Extract up to m /hr at Pa Galvanised steel, double skin casing Triple filter design with F7 pollen filter Over 9% thermal efficiency and low SFP New smart frost protection uilt-in electric post-heater utomatic, % summer bypass uto cut-out switch for extra safety Eight speed digital control with L display and MS (LON / KNX) connection SP ppendix Q eligible and PSSIVE HOUSE Institute certified omplies with uilding Regulations 5 year warranty + Moreover, the mm thick insulation in the casing avoids any thermal bridging and significantly reduces noise levels. The V96SE includes an easily removable, plastic heat 6 exchanger which transfers warmth from the outgoing waste airstream into the incoming fresh air where its thermal efficiency up to 9%. t no point do the airstreams mix. 55 Tested by the RE (uilding Research Establishment) and eligible for the SP ppendix Q V96SE SFP Efficiency K+ Wet room.99 W/l/s 87% K+ Wet rooms.9 W/l/s 87% K+ Wet rooms.99 W/l/s 87% K+ Wet rooms. W/l/s 86% K+5 Wet rooms.6 W/l/s 86% Technical ata Specification uplexvent V96SE R uplexvent V96SE L ir flow m³/hr / Pa / 9 / 9 Thermal efficiency Up to 9% Up to 9% Heat exchanger ounterflow (Plastic) ounterflow (Plastic) Fans E E Summer bypass damper % automatic % automatic Frost protection Frost heater Frost heater ontrols 8-Speed - igital 8-Speed - igital onnection to MS LON / KNX (optional) LON / KNX (optional) Mounting Wall Wall Sound m (d()) uct diameter (mm) x 5 x 5 ondensate discharge (mm) Electrical supply v / ph / 5Hz v / ph / 5Hz Max. power consumption w w Filter class x G / x F7 x G / x F7 Electric frost/post-heater 9w 9w Protection class IP IP asing insulation (mm) Weight (kg) 5 5 imensions (L x x H) mm 6 x x 5 6 x x 5 Part No Passive House ertification imensions Performance 55 5 H I J 5 Extract Supply I The uplexvent V96SE is tested and certified by the Passive House Institute based on the following criteria: Thermal comfort Effective heat recovery Electric power consumption ir tightness alancing adjustability Sound insulation Indoor air quality Frost protection ERTIFIE OMPONENT Passive House Institute E F H J G Q O P N M L K uct outlets, model R Inner diameter of female outlet collar ø 5 mm. Supply air to dwelling. Extract air from dwelling to unit. Exhaust air out. Outdoor air to unit E F G K uct outlets, model L Inner diameter of female outlet collar ø5mm. Exhaust air out. Outdoor air to unit. Supply air to dwelling. Extract air from dwelling to unit L STTI PRESSURE (Pa) E S E5 S6 E6 S5 E S S7 E7 E8 S9E9 S8 S E l/sec m /hr IR FLOW + excludes motors. Motor warranty one year from date of purchase. * Guidance only. ependant upon system pressure. Model E F G H I J K L V96SE ccessories See switches/accessories for more details. v airflow.com ustomer Services airflow.com

12 uplexvent V96SE Professional Line Top Entry - Up to 5 m /hr air volume Fitted with an additional electric post-heater, the unit keeps the indoor air temperature at the required temperature level at all times hence maintains indoor air comfort whilst saving energy during the winter period. The V96SE is designed with a unique triple filter facility including a F7 pollen filter which provides additional protection against invisible, harmful particles and creates an ultra hygienic environment, particularly relevant for those suffering from asthma or other respiratory conditions. The unit includes a digital controller with L display which incorporates 8-speed air flow control, weekly ventilation programming, filter maintenance indicator, separate fan control for easy commissioning and the brand new smart frost protection facility which significantly reduces the energy consumed to protect the heat exchanger from freezing (see below for more information). On-demand ventilation can be achieved by using humidity and O sensors which boost the air volume gradually based on the moisture and occupancy levels in the dwelling. It is also possible to integrate the unit into a uilding Management System via the corresponding US converter (LON or KNX) to monitor and control unit s functions by a central control system. Having the latest, low energy E fan technology, the V96SE complies with the ErP 5 standards. The unit comes with an outstanding 5 year warranty +, is SP ppendix Q eligible, tested by TUV laboratories and also certified by the Passive House Institute. Triple Filter esign The majority of the MVHR units in the U.K incorporate G or G coarse filters on the extract / supply air side. These filters catch only coarse particles such as insects and leaves to protect the heat exchanger. F7 fine filters on the other hand are highly efficient, catch invisible particles such as pollen, spore, bacterium and dust entering the lungs. uplexvent Professional Line units are the only MVHR units which incorporate triple filter design combining G course filters with the F7 fine filter. This significantly improves the indoor air quality and lowers your maintenance costs. G Filter F7 Filter New Smart Frost Protection Traditional Traditional Frost Frost Protection Protection Logic Logic 5 5 Supply Supply ir ir Extract Extract ir ir Supply Supply ir ir +X +X ca.+ ca.+ +X +X FH FH ~% ~% % % % % New New Smart Smart Frost Frost Protection Protection Logic Logic Extract Extract ir ir ca.+ ca.+ (efrosting) (efrosting) ~6% ~6% % % ca. +6 ca. +6 EPH EPH ca. ca. ca. ca. ca. ca. Exhaust Exhaust ir ir ca. ca. Outdoor Outdoor ir ir Exhaust Exhaust ir ir 6 Outdoor ir 6 Outdoor ir Timing Timing and energy and energy consumption consumption graph graph when when Timing Timing and energy and energy consumption consumption graph graph when when frost heater frost heater is used is used electric electric pre-heater pre-heater is usedis used (ca. 5% (ca. less 5% energy less energy consumption) consumption) Time Time Time Time % utomatic ypass The unit is equipped with an automatic, % bypass which totally isolates the heat exchanger so that no air passes through it. This provides effective cooling in the summer season. ontrols Ideal indoor air quality is achieved by automatically adjusted ventilation uplexvent V96SE is controlled via a 8 speed digital control providing the following features: 8 speed control where all speeds are % adjustable utomatic boost function with delay timer Filter maintenance reminder via counter clock (standard) / via pressure sensor (optional) Heater control for post-heater Supply ir to the dwelling Exhaust ir Extract ir from the dwelling Outdoor ir On the traditional frost protection method, the outdoor air is pre-heated before passing through the heat exchanger. This way the unit could still provide balanced ventilation even when the frost protection was on. However, the electric heater kicks in intermittently hence consumes more energy than needed. Supply air fan Exhaust air fan Heat exchanger Electric pre-heater 5 Frost heater 6 Electric bypass damper The new Smart Frost Protection method works in a more energy efficient manner which constantly monitors the heat exchanger conditions and uses the frost heater only when necessary. This significantly reduces the energy consumption and provides more heat recovery throughout the winter season. onnection to MS via LON or KNX Self diagnostic via fault signal relay On-demand control via humidity and O sensors Separate fan control for ease of commissioning Weekly ventilation programming allows users to pre-set the ventilation levels scheduled for different days Indoor temperature control based on extract air temperature or supply air temperature Internet connection available airflow.com ustomer Services airflow.com

13 uplexvent VSE Professional Line Top Entry - Up to 5 m /hr air volume Key Features SP ppendix Q uplexvent VSE The uplexvent VSE is a highly efficient mechanical supply and extract ventilation unit with heat recovery for an air capacity of up to 5 m /hr. It is a wall mounted unit and is delivered complete with a wall mounting plate and condensate drain. The unit is made of a galvanised steel double-skin casing which is powder coated both internally and externally to meet hygiene requirements. For use in medium sized dwellings up to m * Extract up to 9 m /hr at Pa Galvanised steel, double skin casing Triple filter design with F7 pollen filter Over 9% thermal efficiency and low SFP New smart frost protection heater uilt-in electric post-heater utomatic, % summer bypass uto cut-out switch for extra safety Eight speed digital control with L display and MS (LON / KNX) connection SP ppendix Q eligible and PSSIVE HOUSE Institute certified omplies with uilding Regulations 5 year warranty + Moreover, the mm thick insulation in the casing avoids any thermal bridging and significantly reduces noise levels. The VSE includes an easily removable, plastic heat exchanger which transfers warmth from the outgoing waste airstream into the incoming fresh air where its thermal efficiency up to 9%. t no point do the airstreams mix. Tested by the RE (uilding Research Establishment) and eligible for the SP ppendix Q VSE SFP Efficiency K+ Wet room.89 9% K+ Wet rooms.79 9% K+ Wet rooms.79 89% K+ Wet rooms.8 89% K+5 Wet rooms.9 88% K+6 Wet rooms. 88% K+7 Wet rooms.5 87% Technical ata Specification uplexvent VSE R uplexvent VSE L ir flow m³/hr / Pa / 5 / 5 Thermal efficiency Up to 9% Up to 9% Heat exchanger ounterflow (Plastic) ounterflow (Plastic) Fans E E Summer bypass damper % automatic % automatic Frost protection Frost heater Frost heater ontrols 8-Speed - igital 8-Speed - igital onnection to MS LON / KNX (optional) LON / KNX (optional) Mounting Wall Wall Sound m (d()) uct diameter (mm) x 6 x 6 ondensate discharge (mm) J Electrical supply v / ph / 5Hz v / ph / 5Hz I Max. power consumption 8w H 8w Filter class x G / x F7 x G / x F7 Electric frost heater 9w 9w Electric post-heater 9w 9w Protection class IP IP asing insulation (mm) Weight (kg) 6 K L 6 imensions (L x x H) mm 68 x 7 x x 7 x 678 Part No E F G Passive House ertification The uplexvent VSE is tested and certified by the Passive House Institute based on the following criteria: Thermal comfort Effective heat recovery Electric power consumption ir tightness alancing adjustability Sound insulation Indoor air quality Frost protection ERTIFIE OMPONENT Passive House Institute imensions Performance 68 H I J 5 Extract Supply G 678 uct outlets, model R Inner diameter of female outlet collar ø6mm. Supply air to the dwelling. Extract air from dwelling to unit. Exhaust air out. Outdoor air to unit E F K uct outlets, model L Inner diameter of female outlet collar ø6mm. Exhaust air out. Outdoor air to unit. Supply air to the dwelling. Extract air from dwelling to unit L STTI PRESSURE (Pa) E S E5 E S5 S E6 S6 E9 S9 E8 S8 E7 S7 E S l/sec IR FLOW m /hr + excludes motors. Motor warranty one year from date of purchase. Model E F G H I J K L VSE * Guidance only. ependant upon system pressure. ccessories See switches/accessories for more details. v airflow.com ustomer Services airflow.com

14 uplexvent VSE Professional Line Top Entry - Up to 5 m /hr air volume Triple Filter esign Fitted with an additional electric post-heater, the unit keeps the indoor air temperature at the required temperature level at all times hence maintains indoor air comfort whilst saving energy during the winter period. The VSE is designed with a unique triple filter facility including a F7 pollen filter which provides additional protection against invisible, harmful particles and creates an ultra hygienic environment, particularly relevant for those suffering from asthma or other respiratory conditions. The unit includes a digital controller with L display which incorporates 8-speed air flow control, weekly ventilation programming, filter maintenance indicator, separate fan control for easy commissioning and the brand new smart frost protection facility which significantly reduces the energy consumed to protect the heat exchanger from freezing (see below for more information). On-demand ventilation can be achieved by using humidity and O sensors which boost the air volume gradually based on the moisture and occupancy levels in the dwelling. It is also possible to integrate the unit into a uilding Management System via the corresponding US converter (LON or KNX) to monitor and control unit s functions by a central control system. Having the latest, low energy E fan technology, the VSE complies with the ErP 5 standards. The unit comes with an outstanding 5 year warranty +, is SP ppendix Q eligible, tested by TUV laboratories and also certified by the Passive House Institute. The majority of the MVHR units in the U.K incorporate G or G coarse filters on the extract / supply air side. These filters catch only coarse particles such as insects and leaves to protect the heat exchanger. F7 fine filters on the other hand are highly efficient, catch invisible particles such as pollen, spore, bacterium and dust entering the lungs. uplexvent Professional Line units are the only MVHR units which incorporate triple filter design combining G course filters with the F7 fine filter. This significantly improves the indoor air quality and lowers your maintenance costs. G Filter F7 Filter New Smart Frost Protection Traditional Traditional Frost Frost Protection Protection Logic Logic 5 5 Supply Supply ir ir Extract Extract ir ir Supply Supply ir ir +X +X ca.+ ca.+ +X +X FH FH ~% ~% % % % % New New Smart Smart Frost Frost Protection Protection Logic Logic Extract Extract ir ir ca.+ ca.+ (efrosting) (efrosting) ~6% ~6% % % ca. +6 ca. +6 EPH EPH ca. ca. ca. ca. ca. ca. Exhaust Exhaust ir ir ca. ca. Outdoor Outdoor ir ir Exhaust Exhaust ir ir 6 Outdoor ir 6 Outdoor ir Timing Timing and energy and energy consumption consumption graph graph when when Timing Timing and energy and energy consumption consumption graph graph when when frost heater frost heater is used is used electric electric pre-heater pre-heater is usedis used (ca. 5% (ca. less 5% energy less energy consumption) consumption) Time Time Time Time % utomatic ypass The unit is equipped with an automatic, % bypass which totally isolates the heat exchanger so that no air passes through it. This provides effective cooling in the summer season. ontrols Ideal indoor air quality is achieved by automatically adjusted ventilation uplexvent VSE is controlled via a 8 speed digital control providing the following features: 8 speed control where all speeds are % adjustable utomatic boost function with delay timer Filter maintenance reminder via counter clock (standard) / via pressure sensor (optional) Heater control for frost heater and post-heater Supply ir to the dwelling Exhaust ir Extract ir from the dwelling Outdoor ir On the traditional frost protection method, the outdoor air is pre-heated before passing through the heat exchanger. This way the unit could still provide balanced ventilation even when the frost protection was on. However, the electric heater kicks in intermittently hence consumes more energy than needed. Supply air fan Exhaust air fan Heat exchanger Electric pre-heater 5 Frost heater 6 Electric bypass damper The new Smart Frost Protection method works in a more energy efficient manner which constantly monitors the heat exchanger conditions and uses the frost heater only when necessary. This significantly reduces the energy consumption and provides more heat recovery throughout the winter season. onnection to MS via LON or KNX Self diagnostic via fault signal relay On-demand control via humidity and O sensors Separate fan control for ease of commissioning Weekly ventilation programming allows users to pre-set the ventilation levels scheduled for different days Indoor temperature control based on extract air temperature or supply air temperature Internet connection available 6 airflow.com ustomer Services airflow.com

15 uplexvent V5SE Professional Line Top Entry - Up to 59 m /hr air volume Key Features SP ppendix Q uplexvent V5SE The uplexvent V5SE is a highly efficient mechanical supply and extract ventilation unit with heat recovery for an air capacity of up to 59 m /hr. It is a wall mounted unit and is delivered complete with a wall mounting plate and condensate drain. The unit is made of a galvanised steel double-skin casing which is powder coated both internally and externally to meet hygiene requirements. For use in large sized dwellings up to m * Extract up to 57 m /hr at Pa Galvanised steel, double skin casing Triple filter design with F7 pollen filter Over 9% thermal efficiency and low SFP New smart frost protection heater uilt-in electric post-heater utomatic, % summer bypass uto cut-out switch for extra safety Eight speed digital control with L display and MS (LON / KNX) connection SP ppendix Q eligible and PSSIVE HOUSE Institute certified omplies with uilding Regulations 5 year warranty + Moreover, the mm thick insulation in the casing avoids any thermal bridging and significantly reduces noise levels. The V5SE includes an easily removable, aluminium heat exchanger which transfers warmth from the outgoing waste airstream into the incoming fresh air where its thermal efficiency up to 9%. t no point do the airstreams mix. Tested by the RE (uilding Research Establishment) and eligible for the SP ppendix Q V5SE SFP Efficiency K+ Wet room.9 78% K+ Wet rooms.9 8% K+ Wet rooms.89 8% K+ Wet rooms.9 8% K+5 Wet rooms.97 8% K+6 Wet rooms. 8% K+7 Wet rooms.5 8% Technical ata Specification uplexvent V5SE R uplexvent V5SE L ir flow m³/hr / Pa 568 / / 58 Thermal efficiency Up to 9% Up to 9% Heat exchanger ounterflow (luminium) ounterflow (luminium) Fans E E Summer bypass damper % automatic % automatic Frost protection Frost heater Frost heater ontrols 8-Speed - igital 8-Speed - igital onnection to MS LON / KNX (optional) LON / KNX (optional) Mounting Wall / Floor Wall / Floor Sound m (d()) uct diameter (mm) x x ondensate discharge (mm) Electrical supply v / ph / 5Hz v J/ ph / 5Hz Max. power consumption 5w I H 5w Filter class x G / x F7 x G / x F7 Electric frost heater 9w 9w Electric post-heater 5w 5w Protection class IP IP asing insulation (mm) Weight (kg) 88 K 88 imensions (L x x H) mm 78 x 578 x 78 L 78 x 578 x 78 Part No imensions E F G Passive House ertification The uplexvent V5SE is tested and certified by the Passive House Institute based on the following criteria: Thermal comfort Effective heat recovery Electric power consumption ir tightness alancing adjustability Sound insulation Indoor air quality Frost protection Performance ERTIFIE OMPONENT Passive House Institute uct outlets, model R Inner diameter of female outlet collar ø mm. Supply air to the dwelling. Extract air from dwelling to unit. Exhaust air out. Outdoor air to unit E F L M uct outlets, model L Inner diameter of female outlet collar ø mm. Exhaust air out. Outdoor air to unit. Supply air to the dwelling. Extract air from dwelling to unit + excludes motors. Motor warranty one year from date of purchase. Model E F G H I J K L M V5SE G H I J K STTI PRESSURE (Pa) E S Extract Supply S7 E7 S6 E6 E5 S5 E S E9 S9 E8 S S E 5 IR FLOW * Guidance only. ependant upon system pressure. ccessories l/sec m /hr See switches/accessories for more details. v 8 airflow.com ustomer Services airflow.com

16 uplexvent V5SE Professional Line Top Entry - Up to 59 m /hr air volume Triple Filter esign Fitted with an additional electric post-heater, the unit keeps the indoor air temperature at the required temperature level at all times hence maintains indoor air comfort whilst saving energy during the winter period. The V5SE is designed with a unique triple filter facility including a F7 pollen filter which provides additional protection against invisible, harmful particles and creates an ultra hygienic environment, particularly relevant for those suffering from asthma or other respiratory conditions. The unit includes a digital controller with L display which incorporates 8-speed air flow control, weekly ventilation programming, filter maintenance indicator, separate fan control for easy commissioning and the brand new smart frost protection facility which significantly reduces the New Smart Frost Protection Traditional Traditional Frost Frost Protection Protection Logic Logic 5 5 Supply Supply ir ir Extract Extract ir ir Supply Supply ir ir +X +X ca.+ ca.+ +X +X FH FH ~% ~% % % % % energy consumed to protect the heat exchanger from freezing (see below for more information). On-demand ventilation can be achieved by using humidity and O sensors which boost the air volume gradually based on the moisture and occupancy levels in the dwelling. It is also possible to integrate the unit into a uilding Management System via the corresponding US converter (LON or KNX) to monitor and control unit s functions by a central control system. Having the latest, low energy E fan technology, the V5SE complies with the ErP 5 standards. The unit comes with an outstanding 5 year warranty +, is SP ppendix Q eligible, tested by TUV laboratories and also certified by the Passive House Institute. New New Smart Smart Frost Frost Protection Protection Logic Logic Extract Extract ir ir ca.+ ca.+ (efrosting) (efrosting) ~6% ~6% % % ca. +6 ca. +6 EPH EPH ca. ca. ca. ca. ca. ca. Exhaust Exhaust ir ir ca. ca. Outdoor Outdoor ir ir Exhaust Exhaust ir ir 6 Outdoor ir 6 Outdoor ir Timing Timing and energy and energy consumption consumption graph graph when when Timing Timing and energy and energy consumption consumption graph graph when when frost heater frost heater is used is used electric electric pre-heater pre-heater is usedis used (ca. 5% (ca. less 5% energy less energy consumption) consumption) Time Time Time Time The majority of the MVHR units in the U.K incorporate G or G coarse filters on the extract / supply air side. These filters catch only coarse particles such as insects and leaves to protect the heat exchanger. F7 fine filters on the other hand are highly efficient, catch invisible particles such as pollen, spore, bacterium and dust entering the lungs. uplexvent Professional Line units are the only MVHR units which incorporate triple filter design combining G course filters with the F7 fine filter. This significantly improves the indoor air quality and lowers your maintenance costs. % utomatic ypass The unit is equipped with an automatic, % bypass which totally isolates the heat exchanger so that no air passes through it. This provides effective cooling in the summer season. ontrols Ideal indoor air quality is achieved by automatically adjusted ventilation uplexvent V5SE is controlled via a 8 speed digital control providing the following features: 8 speed control where all speeds are % adjustable utomatic boost function with delay timer Filter maintenance reminder via counter clock (standard) / via pressure sensor (optional) Heater control for frost heater and post-heater G Filter Supply ir to the dwelling Exhaust ir Extract ir from the dwelling F7 Filter Outdoor ir On the traditional frost protection method, the outdoor air is pre-heated before passing through the heat exchanger. This way the unit could still provide balanced ventilation even when the frost protection was on. However, the electric heater kicks in intermittently hence consumes more energy than needed. Supply air fan Exhaust air fan Heat exchanger Electric pre-heater 5 Frost heater 6 Electric bypass damper The new Smart Frost Protection method works in a more energy efficient manner which constantly monitors the heat exchanger conditions and uses the frost heater only when necessary. This significantly reduces the energy consumption and provides more heat recovery throughout the winter season. onnection to MS via LON or KNX Self diagnostic via fault signal relay On-demand control via humidity and O sensors Separate fan control for ease of commissioning Weekly ventilation programming allows users to pre-set the ventilation levels scheduled for different days Indoor temperature control based on extract air temperature or supply air temperature Internet connection available airflow.com ustomer Services airflow.com

17 I uplexvent VSE Professional Line Top Entry - Up to 85 m /hr air volume Key Features Technical ata ontrols For use in large sized dwellings up to m * Extract up to 79 m /hr at Pa Galvanised steel, double skin casing Triple filter design with F7 pollen filter Up to 9% thermal efficiency and low SFP uilt-in electric or water post-heater utomatic, % bypass and frost protection uto cut-out switch for extra safety Eight speed digital control with L display and MS (LON / KNX) connection omplies with uilding Regulations 5 year warranty + Specification uplexvent VSE R uplexvent VSE L ir flow m /hr / Pa 88 / 88 / Thermal efficiency Up to 9% Up to 9% Heat exchanger ounterflow (luminium) ounterflow (luminium) Fans E E Summer bypass damper % automatic % automatic Frost protection Frost heater Frost heater ontrols 8-Speed - igital 8-Speed - igital onnection to MS LON / KNX (optional) LON / KNX (optional) Mounting Floor Floor Sound m (d()) uct diameter (mm) x x ondensate discharge (mm) Electrical supply v / ph / 5Hz v / ph / 5Hz Max. power consumption 5w E F 5w Filter class x G / x F7 x G / x F7 Electric frost heater w w J Ideal indoor air quality is achieved by automatically adjusted ventilation uplexvent VSE is controlled via a 8 speed digital control providing the following features: 8 speed control where both fans are % adjustable utomatic boost function with delay timer Filter maintenance reminder via counter clock (standard) / via pressure sensor (optional) Heater control for frost heater and post-heater onnection to MS via LON or KNX Self diagnostic via fault signal relay On-demand control via humidity and O sensors uplexvent VSE With its powerful air volume capacity and high thermal efficiency the uplexvent VSE is suitable for large family houses or light commercial applications. The automatic, % summer bypass facility isolates the heat recovery function and helps to effectively cool the inside air during the summer months. Electric post-heater w (optional) w (optional) Water post-heater w (optional) w (optional) Protection class IP IP asing insulation (mm) 5 5 Weight (kg) 6 6 imensions (L x x H) mm 9 x 7 x N M L 9 K x 7 x Part No G H O P Q Separate fan control for ease of commissioning Weekly ventilation programming allows users to preset the ventilation levels scheduled for different days Indoor temperature control based on extract air temperature or supply air temperature Internet connection available Having the triple filter design with an F7 pollen filter, the VSE provides additional protection against invisible, harmful particles and creates an ultra hygienic environment. The unit includes an easily removable, aluminium heat exchanger and can be equipped with a built-in electric or water post-heater to increase the heat performance of the system. 9 MOEL - L imensions E F G H I J K Performance H I J K E F G M N O P Q Extract Supply MOEL - R uct outlets, inner diameter of collar ømm + excludes motors. Motor warranty one year from date of purchase. Model E F G H I J VSE K L M N O P Q R S T L Outdoor air to unit Extract air from the dwelling Supply air to the dwelling Exhaust air out Pipe connections. Supply water to the radiator. Return water from the radiator. Supply liquid to the water heater. Return liquid from the water heater R S T Electrical connections 5. onnection cable Humidity sensor 6. onnection cable ontrol panel O sensor LON converter 7. Feed cable istribution panel STTI PRESSURE (Pa) E S S S5 E E5 S6 E6 S7 S8 E7 S9 E8 S E9E l/sec m /hr IR FLOW ccessories * Guidance only. ependant upon system pressure. See switches/accessories for more details. v L M airflow.com ustomer Services airflow.com

18 I uplexvent V5 Professional Line Side Entry - Up to m /hr air volume Key Features SP ppendix Q Passive House ertification For use in small sized dwellings up to m * Extract up to 6 m /hr at Pa Tested by the RE (uilding Research Establishment) and eligible for the SP ppendix Q The uplexvent V5 is tested and certified by the Passive House Institute based on the following criteria: uplexvent V5 Unique maintenance feature enables external access from outside dwelling Triple filter design with F7 pollen filter Up to 9% thermal efficiency and low SFP New smart frost protection uilt-in electric post-heater utomatic, % summer bypass Low height (6mm) for suspended ceiling application SP ppendix Q eligible and PSSIVE HOUSE Institute certified omplies with uilding Regulations 5 year warranty + V5 SFP Efficiency K+ Wet room.9 W/l/s 79% K+ Wet rooms.95 W/l/s 8% K+ Wet rooms. W/l/s 8% K+ Wet rooms.9 W/l/s 8% Technical data Specification uplexvent V5 R uplexvent V5 L ir flow m /hr / Pa / 6 / 6 Thermal efficiency Up to 9% Up to 9% Heat exchanger ounterflow (luminium) ounterflow (luminium) Fans E E Summer bypass damper % automatic % automatic Frost protection Frost heater Frost heater ontrols -Speed - Manual igital (optional) -Speed - Manual igital (optional) Mounting Floor / eiling Floor / eiling Sound m (d()) Thermal comfort Effective heat recovery Electric power consumption ir tightness alancing adjustability Sound insulation Indoor air quality ontrols Four Speed Switch ERTIFIE OMPONENT Passive House Institute uplexvent V5 is controlled via a speed switch or an optional digital controller which allows % variable control at each speed setting. Easy to install, simple to use Manual/automatic boost with timer Maintenance indicator and self diagnostic uplexvent V5 brings a new approach to the heat recovery ventilation with a low profile design. It can be integrated into the structure of the dwelling, i.e. above the entry door so routine maintenance can be performed from the outside corridor without disturbing the resident. This ensures quick and easy maintenance and is ideal for apartment blocks. The unit includes an easy to remove, aluminium heat exchanger which transfers warmth from the outgoing waste airstream into the incoming fresh air where at no point do the airstreams mix. uct diameter (mm) 8 x 8 x ondensate discharge (mm) Electrical supply v / ph / 5Hz v / ph / 5Hz Max. power consumption w w Filter class x G / x F7 x G / x F7 Electric frost/post-heater 9w 9w Protection class IP IP asing insulation (mm) Weight (kg) 5 5 imensions (L x x H) mm 9 x 57 x 6 9 x 57 x 6 Part No Manual control switch igital controller imensions Performance FRONT PRT OF UNIT Right side SEEN FROM OVE SEEN FROM EHIN + excludes motors. Motor warranty one year from date of purchase. Model V Left side Model R Inner diameter of female outlet collar ømm. Outdoor air to the unit. Supply air to rooms. Extract air to the unit. Exhaust air outside Model L Inner diameter of female outlet collar ømm. Extract air to the unit. Exhaust air outside. Outdoor air to the unit. Supply air to rooms STTI PRESSURE (Pa) 5 E F Extract E9 Supply S9 E S E8 S8 E7 S7 5 E5 E6 S6 S5 N M L K E S 5 E S l/sec G H O J Q P m /hr IR FLOW * Guidance only. ependant upon system pressure. ccessories See switches/accessories for more details. v airflow.com ustomer Services airflow.com

19 uplexvent V5 Professional Line Side Entry - Up to m /hr air volume The unit incorporates the brand new smart frost protection facility which significantly reduces the energy consumed to protect the heat exchanger from freezing (see below for more information). Equipped with a -speed simple controller the unit also has an automatic, % bypass facility which fully covers the heat exchanger at the pre-defined temperature and helps to effectively cool the indoor air during the summer months. The V5 is designed with a unique triple filter facility including a F7 pollen filter which provides additional protection against invisible, harmful particles and creates an ultra hygienic environment, particularly relevant for those suffering from asthma or other respiratory conditions. The unique multi spigot design gives installers the flexibility to connect the ducting to the unit from different directions which reduces the number of duct connections and saves time on installation. Fitted with an electric post-heater, the unit keeps the indoor air temperature at the required temperature level at all times hence saves energy especially during the winter period. Having the latest, low energy E fan technology, the V5 complies with the ErP 5 standards. The unit comes with an outstanding 5 year warranty +, is SP ppendix Q eligible, tested by TUV laboratories and also certified by the Passive House Institute. % utomatic ypass The unit is equipped with an automatic, % bypass which totally isolates the heat exchanger so that no air passes through it. This provides effective cooling in the summer season. Exhaust ir Outdoor ir Multi Spigot esign The unique multi spigot design gives installers the flexibility to connect the ducting to the unit from different directions which reduces the number of duct connections and saves time on installation. OUTSIE INSIE Supply ir Extract ir Outdoor ir Exhaust ir New Smart Frost Protection Supply ir to the dwelling Extract ir from the dwelling Traditional Traditional Frost Frost Protection Protection Logic Logic 5 5 Supply Supply ir ir Extract Extract ir ir Supply Supply ir ir +X +X ca.+ ca.+ +X +X FH FH ~% ~% % % % % New New Smart Smart Frost Frost Protection Protection Logic Logic Extract Extract ir ir ca.+ ca.+ (efrosting) (efrosting) ~6% ~6% % % ca. +6 ca. +6 EPH EPH ca. ca. ca. ca. ca. ca. Exhaust Exhaust ir ir ca. ca. Outdoor Outdoor ir ir Exhaust Exhaust ir ir 6 Outdoor ir 6 Outdoor ir Timing Timing and energy and energy consumption consumption graph graph when when Timing Timing and energy and energy consumption consumption graph graph when when frost heater frost heater is used is used electric electric pre-heater pre-heater is usedis used (ca. 5% (ca. less 5% energy less energy consumption) consumption) Time Time On the traditional frost protection method, the outdoor air is pre-heated before passing through the heat exchanger. This way the unit could still provide balanced ventilation even when the frost protection was on. However, the electric heater kicks in intermittently hence consumes more energy than needed. Time Time The new Smart Frost Protection method works in a more energy efficient manner which constantly monitors the heat exchanger conditions and uses the frost heater only when necessary. This significantly reduces the energy consumption and provides more heat recovery throughout the winter season. ccessability Landlords can protect their investment by insuring planned maintenance from outside the dwelling to preserve building fabric, ensure occupier wellbeing and save energy without the need to access the dwelling or disturb the tenant. This significantly shortens maintenance time and saves on service cost. Supply air fan Exhaust air fan Heat exchanger Electric pre-heater 5 Frost heater 6 Electric bypass damper 6 airflow.com ustomer Services airflow.com

20 I uplexvent V8 Professional Line Side Entry - Up to 6 m /hr air volume Key Features SP ppendix Q Passive House ertification For use in medium sized dwellings up to 8 m * Extract up to m /hr at Pa Unique maintenance feature enables external access from outside dwelling Triple filter design with F7 pollen filter Over 9% thermal efficiency and low SFP New smart frost protection heater uilt-in electric post-heater Tested by the RE (uilding Research Establishment) and eligible for the SP ppendix Q V8 SFP Efficiency K+ Wet room.79 W/l/s 9% K+ Wet rooms.79 W/l/s 9% K+ Wet rooms.86 W/l/s 9% K+ Wet rooms. W/l/s 9% K+5 Wet rooms.6 W/l/s 89% K+6 Wet rooms.8 W/l/s 89% The uplexvent V8 is tested and certified by the Passive House Institute based on the following criteria: Thermal comfort Effective heat recovery Electric power consumption ir tightness alancing adjustability Sound insulation Indoor air quality Frost protection ERTIFIE OMPONENT Passive House Institute uplexvent V8 uplexvent V8 brings a new approach to the heat recovery ventilation with a low profile design. It can be integrated into the structure of the dwelling, i.e. above the entry door so routine maintenance can be performed from the outside corridor without disturbing the resident. This ensures quick and easy maintenance for and is ideal for apartment blocks. utomatic, % summer bypass Low height (9mm) for suspended ceiling application SP ppendix Q eligible and PSSIVE HOUSE Institute certified omplies with uilding Regulations 5 years warranty + The unit includes an easy to remove, plastic heat exchanger which transfers warmth from the outgoing waste airstream into the incoming fresh air where its thermal efficiency up to 9%. t no point do the airstreams mix. Technical ata Specification uplexvent V8 R uplexvent V8 L ir flow m /hr / Pa 56 / / 99 Thermal efficiency Up to 9% Up to 9% Heat exchanger ounterflow (Plastic) ounterflow (Plastic) Fans E E Summer bypass damper % automatic % automatic Frost protection Frost heater Frost heater ontrols -Speed - Manual igital optional -Speed - Manual igital optional Mounting Floor / eiling Floor / eiling Sound m (d()) uct diameter (mm) 8 x 5 8 x 5 ondensate discharge (mm) Electrical supply v / ph / 5Hz v / ph / 5Hz Max. power consumption 65w 65w Filter class x G / x F7 x G / x F7 Electric frost heater 9w 9w Electric post-heater 9w 9w Protection class IP IP asing insulation (mm) Weight (kg) imensions (L x x H) mm 6 x 66 x 9 6 x 66 x 9 Part No ontrols Four Speed Switch uplexvent V8 is controlled via a speed switch or an optional digital controller which allows % variable control at each speed setting. Easy to install, simple to use Manual/automatic boost with timer Maintenance indicator and self diagnostic Manual control switch igital controller imensions Performance FRONT PRT OF UNIT Right side SEEN FROM OVE SEEN FROM EHIN Left side Model - R Inner diameter of female outlet collar ø5mm. Outdoor air to the unit. Supply air to rooms. Extract air to the unit. Exhaust air outside Model - L Inner diameter of female outlet collar ø5mm. Extract air to the unit. Exhaust air outside. Outdoor air to the unit. Supply air to rooms G H O STTI PRESSURE (Pa) 5 E F Extract Supply E 5 S E9 S9 E8 5 S8 E7 S7 N 5 M L K E6 S6 E5 S5 E 5 S E S J Q P l/sec m /hr IR FLOW + excludes motors. Motor warranty one year from date of purchase. * Guidance only. ependant upon system pressure. Model V ccessories See switches/accessories for more details. v 8 airflow.com ustomer Services airflow.com

Duplexvent DV72 EC So light, so slim it fits inside a 600mm cupboard

Duplexvent DV72 EC So light, so slim it fits inside a 600mm cupboard Duplexvent DV72 EC So light, so slim it fits inside a 600mm cupboard Duplexvent DV72 EC MVHR is designed to provide constant volume ventilation levels to exceed the latest Building Regulations 2010. The

More information

MODEL: DV72. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual. Configuration Left Hand Right Hand

MODEL: DV72. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual. Configuration Left Hand Right Hand 9041381- Issue 6 4/11 MODEL: DV72 Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual Commissioning Data: to be completed by the installer Date of installation: Configuration

More information

NEW! Flexit SL4 R. Air Handling Unit with rotating recovery system Energy-efficient New control system. Patent applied for!

NEW! Flexit SL4 R. Air Handling Unit with rotating recovery system Energy-efficient New control system. Patent applied for! Flexit SL4 R Air Handling Unit with rotating recovery system Energy-efficient New control system NEW! Patent applied for! - Simple settings - Flexible installation - User friendly F O R H E A LT H Y I

More information

HRU ECO 4. System 4 Continuous Mechanical Supply and Extract Ventilation with Heat Recovery Appendix Q Eligible

HRU ECO 4. System 4 Continuous Mechanical Supply and Extract Ventilation with Heat Recovery Appendix Q Eligible HRU ECO 4 System 4 Continuous Mechanical Supply and Extract Ventilation with Heat Recovery Appendix Q Eligible Weight As a result of the unique clamping construction in combination with the plastic/synthetic

More information

Zehnder Focus 200. Ventilation device

Zehnder Focus 200. Ventilation device Ventilation device Use The Zehnder Focus (F) 200 comfort ventilation unit was specially developed for use in demanding residential and commercial buildings. It combines maximum comfort, simple operation

More information

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features RKE Heat recovery unit from 200 to 6800 m 3 /h General features RKE heat recovery units are suitable for residential and commercial applications and offer a real energy saving in forced ventilation plants,

More information

TD-SILENT Series (160 to 1000 models) TD-SILENT Series (1300 and 2000 models) NEW TD-SILENT. In-Line duct fans

TD-SILENT Series (160 to 1000 models) TD-SILENT Series (1300 and 2000 models) NEW TD-SILENT. In-Line duct fans IN-LINE MIXED LOW DUT ANS ultra-quiet Series (16 to 1 models) Low profile Mixed-flow fans with sound-absorbent insulation. Extremely quiet. ertified of Approval Noise Abatement Society (TD-35, TD-5, TD-8

More information

Solar air collectors for industry and larger halls S Ø. Efficient dehumidification and air heating for free...

Solar air collectors for industry and larger halls S Ø. Efficient dehumidification and air heating for free... Solar air collectors for industry and larger halls N S Ø Efficient dehumidification and air heating for free... This booklet contains information about SolarVenti Industrial air solar system. The system

More information

121MC. Vallox. Low-energy ventilation unit with heat recovery. Operating, maintenance and technical instructions. Vallox 1.09.420 EN 14.5.

121MC. Vallox. Low-energy ventilation unit with heat recovery. Operating, maintenance and technical instructions. Vallox 1.09.420 EN 14.5. Code 3561 Models VALLOX 121 MC R VALLOX 121 MC L Low-energy ventilation unit with heat recovery Vallox 1.09.420 EN 14.5.2013 Operating, maintenance and technical instructions 1 Extract air fan 2 Supply

More information

Horizontal ventilation units

Horizontal ventilation units THE ART OF AIR INNOVATION SINCE 1983 FOR HOMES AND BUSINESSES Horizontal ventilation units Healthy indoor air increases your well-being Today people spend much of their life indoors. It is therefore important

More information

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series SWIMMING POOL AIR-HANDLING UNITS KU-DB Series ME20 proklima 2 SWIMMING POOL AIR-HANDLING UNITS - KU-DB Series proklima 3 TABLE OF CONTENTS 1 Introduction page 3 2 Features page 4 SWIMMING POOL AREA t =

More information

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information

USER S MANUAL HSC-24A

USER S MANUAL HSC-24A AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL

More information

How To Make Your House Breathe

How To Make Your House Breathe RENEWABLES VENTILATION UNITS Nothing lost plenty of healthy fresh air gained Innovative ventilation units that offer healthy indoor air and significantly lower energy bills 04 2015 STIEBEL ELTRON is full

More information

Under sill units. Type FSL-B-ZAS

Under sill units. Type FSL-B-ZAS .1 X X testregistrierung Under sill units Type, heat recovery Centrifugal fan Adaptive heat recovery damper HYGIENISCH GETESTET V DI 022 Tested to VDI 022 Secondary air unit for supply air and extract

More information

Installation, operation and maintenance manual TX 35A

Installation, operation and maintenance manual TX 35A Installation, operation and maintenance manual TX 35A Rev.10 may 2012 Page 1 of 18 1.0.0 Table of contents INSTALLATION, OPERATION AND MAINTENANCE MANUAL...1 1.0.0 TABLE OF CONTENTS...2 2.0.0 ILLUSTRATIONS...2

More information

How To Get A Passive House

How To Get A Passive House Certificate Certified Passive House Component For cool, temperate climates, valid until 31 December 2015 Passive House Institute Dr. Wolfgang Feist 64283 Darmstadt GERMANY Category: Manufacturer: Product

More information

Gas Condensing Boilers

Gas Condensing Boilers Gas Condensing Boilers www.johnsonandstarley.co.uk QuanTec Ultra Efficient Condensing Gas Boilers Including HR28C with Integral Passive Flue Gas Heat Recovery As market leaders and innovators, Johnson

More information

06150 PORVOO, FINLAND Pelican eco ED(D), Pelican eco EDE(D), Pelican eco EDW(D), Pelican eco EDX(D)

06150 PORVOO, FINLAND Pelican eco ED(D), Pelican eco EDE(D), Pelican eco EDW(D), Pelican eco EDX(D) Certificate Certified Passive House Component For cool, temperate climates, valid until 31 December 2013 Passive House Institute Dr. Wolfgang Feist 64283 Darmstadt GERMANY Category: Manufacturer: Heat

More information

CADB and CADT-D / DI / DC Series

CADB and CADT-D / DI / DC Series HEAT RECOVERY UNITS CADB and CADT-D / DI / DC Series NEW The CADB, CADT heat recovery range consists of: - Self-supporting casing with extruded aluminium profile structure and beige plastic coated galvanised

More information

DIMENSIONS SELV MODELS

DIMENSIONS SELV MODELS 25 CURZON - 1mm CENTRIFUGL FNS DIMENSIONS B Ø C D E Measured in mm : 216 B : 195 C : 5 D : 52 E : 98 Ø* * : 8/1 * (8mm without adaptor 1mm with adaptor) CURZON - 1mm CENTRIFUGL FNS 14 12 1 8 6 4 2 14 12

More information

Mistrale. Fusion Terminal

Mistrale. Fusion Terminal Mistrale Fusion Terminal PUBLICATION NATURAL VENT. 1 SEPT 2015 Features - Slimline energy efficient ventilation solution - Standard and high capacity terminals provide 128 or 256 L/s capacity - Compliant

More information

Flexit air handling unit K2 R

Flexit air handling unit K2 R Flexit air handling unit K2 R with integrated kitchen hood PATENTED The quietest on the market Modern design Energy-efficient Installation in the kitchen A FOR A HEALTHY ENVIRONMENT Requirement-controlled

More information

Heating oven with mechanical convection

Heating oven with mechanical convection FD series 53 Drying ovens / Heating ovens Heating oven with mechanical convection A BINDER FD series heating oven is always used when fast drying and sterilization is required. Thanks to its fully homogeneous

More information

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F400-120. advantages.

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F400-120. advantages. Défumair XR smoke-extraction fan extraction casing for kitchen at F400-120 Personalisation : - Phonic insulation version by insulated double-skin panels through 25 mm glass wool, class M1. advantages Originally

More information

Material test chamber with mechanical convection

Material test chamber with mechanical convection FP series 400 Material test chambers Material test chamber with mechanical convection A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and

More information

HEAVY DUTY STORAGE GAS

HEAVY DUTY STORAGE GAS Multi-Fin flue technology Flue damper saves energy Electronic controls HEAVY DUTY STORAGE GAS Dependability The Rheem heavy duty gas range is the work horse of the industry having proved itself over many

More information

CE6500 Energy Recovery Ventilator

CE6500 Energy Recovery Ventilator ADVANCED COMMERCIAL Energy Recovery Ventilator PRODUCT SPECIFICATIONS & TECHNICAL DATA Features NOMINAL CAPACITY 5500-7000 CFM CASING Double-wall cabinet White exterior paint, -gauge galvanized steel -gauge

More information

Air Movement. Heaters Desk Fans Wall Fans Pedestal Fans Ceiling Fans Extractor Fans Hand Dryers Air Conditioners. Pg 83 84 85 85 86 88 89 90

Air Movement. Heaters Desk Fans Wall Fans Pedestal Fans Ceiling Fans Extractor Fans Hand Dryers Air Conditioners. Pg 83 84 85 85 86 88 89 90 6 Air Movement Heaters Desk Fans Wall Fans Pedestal Fans Ceiling Fans Extractor Fans Hand Dryers Air Conditioners Pg 83 84 85 85 86 88 89 90 83 Air Movement JKI Heaters Aurora Bathroom Heater Quartz 2

More information

Delivering exceptional performance and Ecovalue. Ecocent

Delivering exceptional performance and Ecovalue. Ecocent 1 Delivering exceptional performance and Ecovalue. Ecocent 2 The Ecocent Hot Water System As the cost of providing heating and hot water continues to increase, homes and businesses are seeking out more

More information

FLAT TECHNICAL DATA. HEAT RECOVERY VENTILATION UNITS for RESIDENTIAL BUILDINGS. indoor air quality and energy saving ENERGY CLASS B A A B A A UNIT

FLAT TECHNICAL DATA. HEAT RECOVERY VENTILATION UNITS for RESIDENTIAL BUILDINGS. indoor air quality and energy saving ENERGY CLASS B A A B A A UNIT indoor air quality and energy saving TECHNICL DT UNIT FLT 1 FLT 2 CONTROL CTR08-PH EVO(D)-PH EVO(D)-PH + CO 2sensor CTR08-PH EVO(D)-PH EVO(D)-PH + CO 2 sensor ENERGY CLSS + C D E F G FLT HET RECOVERY VENTILTION

More information

Indoor Air Quality FILL YOUR HOME WITH AIR THAT IS AS CLEAN AS IT IS COMFORTABLE. READ ONLY

Indoor Air Quality FILL YOUR HOME WITH AIR THAT IS AS CLEAN AS IT IS COMFORTABLE. READ ONLY Indoor Air Quality FILL YOUR HOME WITH AIR THAT IS AS CLEAN AS IT IS COMFORTABLE. QUALITY AIR STARTS HERE. AccuExchange Energy Recovery Ventilator Improve your home s indoor environment by exchanging stale

More information

Electric Flow Boiler

Electric Flow Boiler Electric Flow Boiler EHC offer the most comprehensive range of electric boilers in the market and with our wealth of knowledge and technical expertise we have designed the Slim Jim Electric Flow Boiler

More information

Portable Air Conditioner

Portable Air Conditioner Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE

More information

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power R22. K Control. Indoor Unit. Nomenclature. PL H 3 G K H B Compatibility Unit style Heat Pump Horse Power Control Boost Heaters R22. K Control. Outdoor Unit. Nomenclature. PU H 3 Y K A Compatibility Outdoor

More information

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner Elegant ECM Ceiling Air Conditioner ELEGANT ECM air conditioners allow to heat and cool very economically small and medium areas, like shops, show rooms, workshops, supermarkets. The range is made up of

More information

Incubator with mechanical convection

Incubator with mechanical convection BF series 400 Incubators and cooling incubators Incubator with mechanical convection The BINDER incubator of the BF series with mechanical convection is suitable for all gentle incubation applications,

More information

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power: PHOTOVOLTAIC (PV) solar panels Electricity - CE & ISO 9000 certified Photovoltaic solar panels convert sunlight into useful electricity. ZEDfabric supplies high quality mono-crystalline silicon cell PV

More information

Operation and Installation Manual. Max Series

Operation and Installation Manual. Max Series Operation and Installation Manual Max Series Models 95MAX 155MAX 155ECM 155MAXRX 200MAX 200MAXRX MAXTOP 195DCS 300DCS 200ERV 200ERVD New Auto Dehumidistat Function prevents unwanted use of the dehumidistat

More information

squrboxbox heat recovery squrboxbox I technical information

squrboxbox heat recovery squrboxbox I technical information heatrecoveryrange heat recovery squrboxbox I technical information squrboxbox Low depth high performance Only 350mm deep & up to 430l/s, providing the most effective low depth solution. Quietest solution

More information

Key energy-efficient features of your new home

Key energy-efficient features of your new home Key energy-efficient features of your new home Your thermal envelope The thermal envelope, or shell, of your home (walls, roof and floor) is designed to keep you dry and comfortable. It protects you from

More information

Unico Inverter. Unique and efficient.

Unico Inverter. Unique and efficient. Unico Inverter. Unique and efficient. INTERNATIONAL PATENT PENDING The first fixed air conditioner without outdoor unit featuring DC Inverter technology. Great performance, reduced consumption. Designed

More information

HVAC air curtains. Type InduAir

HVAC air curtains. Type InduAir Air Conditioning Cooling Heating Ventilation HVAC air curtains Type InduAir The Energy Saving air curtain for Industrial Applications InduAir The solid, self-supporting housing of the energy saving air

More information

IH 17025 E Sigma Island 90

IH 17025 E Sigma Island 90 INSTRUCTIONS FOR USE Kitchen extractor hood Type: IH 17025 E Sigma Island 90 Dear Customer!! You are now a user of the newest generation kitchen extractor hood type IH 17025 E Sigma Island 90. This hood

More information

Heating and cooling a home in Australia amounts to around

Heating and cooling a home in Australia amounts to around Heating and cooling a home in Australia amounts to around 23% of household energy use, second to only hot water. Gas is one of the most greenhouse friendly fuel sources available and selection of a Rinnai

More information

DUCTED AIR CONDITIONING SOLUTIONS

DUCTED AIR CONDITIONING SOLUTIONS DUCTED AIR CONDITIONING SOLUTIONS H I G H E N E R G Y E F F I C I E N C Y B A C K E D B Y A 5 Y E A R F U L L P A R T S & L A B O U R W A R R A N T Y DUCTED RANGE WHY CHOOSE FUJITSU? AUSTRALIA S FAVOURITE

More information

Series IDU/IDF. Refrigerated Air Dryer

Series IDU/IDF. Refrigerated Air Dryer Refrigerated ir ryer Series IU/IF The models IF1 to 11 and IU3 to 6 have been revised. For details, refer to catalog no. S30-8. Similar updating for other IF/IU models is scheduled to follow shortly. In

More information

Bring the fresh in. Dedicated Outside Air Systems

Bring the fresh in. Dedicated Outside Air Systems Bring the fresh in. Dedicated Outside Air Systems The inside story on outside air. On average, we breathe in 3,400 gallons of air each day. Ambient indoor air pollution is a major problem, affecting health

More information

Energy Efficiency HOSPITALITY. www.energia.ie

Energy Efficiency HOSPITALITY. www.energia.ie Energy Efficiency HOSPITALITY www.energia.ie Your chance to reduce your business energy usage by as much as 20%! 20% is a significant figure and reducing your energy bill by this amount could make a real

More information

Airline. small air handlers and extract fan units. VES Airline part of a complete range of innovative, flexible products from the HVAC experts

Airline. small air handlers and extract fan units. VES Airline part of a complete range of innovative, flexible products from the HVAC experts Lo w p r o f i l e small air handlers and extract fan units Duties to 0.55m 3 /sec Available with the Electroline fitted control panel Ceiling void friendly - unit heights from 190mm to 350mm Airline VES

More information

Solar Homes Catch the Sun. Are you planning a new house? Discover how you can apply solar architecture principles to:

Solar Homes Catch the Sun. Are you planning a new house? Discover how you can apply solar architecture principles to: PASSIVE Solar Design Solar Homes Catch the Sun Are you planning a new house? Discover how you can apply solar architecture principles to: keep your heating bills to a minimum enjoy the comfort of a warm

More information

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan TABLE OF CONTENTS INTRODUCTION 2 IMPORTANT SAFEGUARDS...2 PACKAGE CONTAINS..2 NAMES OF PARTS.3

More information

UDSA - UDSBD unit heater

UDSA - UDSBD unit heater APPLICATIONS Heating >> FACTORIES >> WAREHOUSES >> HALLS >> SHOWROOMS >> GREENHOUSES >> RETAIL >>... UDSA - UDSBD unit heater www.reznor.eu V3 gas fired unit heater Reznor V3 unit heaters are one of the

More information

Comfosystems Systems with heat recovery for a comfortable indoor climate

Comfosystems Systems with heat recovery for a comfortable indoor climate Comfosystems Systems with heat recovery for a comfortable indoor climate always around you Heating Cooling Fresh Air Clean Air Zehnder everything you need to create a comfortable, healthy and energy-efficient

More information

RPV - RP - RA air handling units

RPV - RP - RA air handling units APPLICATIONS Heating, ventilation, cooling >> FACTORIES >> WAREHOUSES >> HALLS >> DISTRIBUTION CENTRES >> COMMERCIAL PREMISES >> PLACES OF WORSHIP RPV - RP - RA air handling units www.reznor.eu RPV - RP

More information

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools Heat Recovery Dehumidification (HRD) system Designed for municipal swimming pools A dehumidification and ventilation system with dynamic heat pump heat recovery to swimming pool water and air ENVIRONMENTAL

More information

News! Flexit S20 R. Air Handling Unit. A new generation of Air Handling Units. For a healthy indoor envionment

News! Flexit S20 R. Air Handling Unit. A new generation of Air Handling Units. For a healthy indoor envionment News! Flexit S20 R Air Handling Unit A new generation of Air Handling Units For a healthy indoor envionment Flexit S20 R Air Handling Unit Flexit is launching a new range of air handling units with capacity

More information

SECTION 11 78 13 MORTUARY REFRIGERATORS

SECTION 11 78 13 MORTUARY REFRIGERATORS PART 1 - GENERAL 1.1 DESCRIPTION SECTION 11 78 13 MORTUARY REFRIGERATORS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also delete any other item or paragraph not applicable in

More information

Heating oven with mechanical control

Heating oven with mechanical control ED series 53 Drying ovens / Heating ovens Heating oven with mechanical control The strength of the BINDER ED series heating oven: routine drying and sterilization applications up to 300 C (572 F). Thanks

More information

Cooking at the Speed of light!

Cooking at the Speed of light! Cooking at the Infrared Cooking & Colouring Infrabaker is a modular infrared continuous cooking system developed by Infrabaker International. The machine is designed to cook and/or put colour on a wide

More information

FLEXIT S4 R S6 R S7 R

FLEXIT S4 R S6 R S7 R 94111E-05 2005-10 FLEXIT S4 R S6 R S7 R User Manual Air Handling Unit Cabinet Models with Heat Recovery - Rotor Contents 1 Important Safety Instructions... 3 2 Method of Operation - System... 3 2.1 Heating

More information

Trane Ductless Systems. Get comfortable with a smart solution. READ ONLY

Trane Ductless Systems. Get comfortable with a smart solution. READ ONLY Trane Ductless Systems Get comfortable with a smart solution. Trane Ductless Systems. A smart solution for efficient comfort, where and when you need it. Trane has a tradition of quality lasting more than

More information

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None 1-Way Chilled Water Cassettes KCO 60, 90 & 120 Technical Brochure TM KCO-W.1GB Date : November 2005 Supersedes : None General Features Control valve (optional) Air vent In-tube electric heating elements

More information

READ ONLY INNOVATIVE SYSTEMS FOR PERFECTLY CONDITIONED AIR TRANE AIR HANDLERS TRANE AIR HANDLERS. Consistent comfort throughout your home

READ ONLY INNOVATIVE SYSTEMS FOR PERFECTLY CONDITIONED AIR TRANE AIR HANDLERS TRANE AIR HANDLERS. Consistent comfort throughout your home TRANE AIR HANDLERS READ ONLY TRANE AIR HANDLERS INNOVATIVE SYSTEMS FOR PERFECTLY CONDITIONED AIR Consistent comfort throughout your home TFB/TFE READ ONLY TGB TEH/TEC TEE with built-in Trane CleanEffects

More information

94210E-03 2005-10 L7 X W. User Manual. Air Handling Unit Loft Models with water-based heating

94210E-03 2005-10 L7 X W. User Manual. Air Handling Unit Loft Models with water-based heating 94210E-03 2005-10 FLEXIT L4 X W L7 X W User Manual Air Handling Unit Loft Models with water-based heating Contents 1 Important Safety Instructions... 3 2 Method of Operation - System... 3 3 Operation -

More information

Trane Ductless Systems. Get comfortable with a smart solution. READ ONLY

Trane Ductless Systems. Get comfortable with a smart solution. READ ONLY Trane Ductless Systems Get comfortable with a smart solution. Trane Ductless Systems. A smart solution for efficient comfort, where and when you need it. Trane has a tradition of quality lasting more than

More information

We have been working in an ideal climate for thirty years.

We have been working in an ideal climate for thirty years. Underfloor cooling We have been working in an ideal climate for thirty years. A climate that has brought us to a position of leadership in Italy in the field of radiant heating and cooling. RDZ was the

More information

about your house How to Get the Ventilation That You Need in Your House Figure 1 Infiltration and exfiltration of air in a house

about your house How to Get the Ventilation That You Need in Your House Figure 1 Infiltration and exfiltration of air in a house about your house CE 64 How to Get the Ventilation That You Need in Your House Canadian houses are relatively airtight, and have been for years. The old farmhouses where people lived several generations

More information

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient

More information

warm air for the healthiest, most comfortable home environment possible. This occurs with a system efficiency of up to 90%.

warm air for the healthiest, most comfortable home environment possible. This occurs with a system efficiency of up to 90%. Lifebreath delivers a complete indoor climate control package Indoor comfort in a small package The patented Lifebreath Clean Air Furnace combines the fresh air benefits of the Heat Recovery Ventilator

More information

eq Top/TopMaster Air Magic by Fläkt Woods

eq Top/TopMaster Air Magic by Fläkt Woods eq Top/TopMaster Air Magic by Fläkt Woods Compact and energy efficient air handling units eq Top and TopMaster Save Energy, Economy and Environment with Fläkt Woods Energy optimization is an important

More information

Part 3 Ancillary technologies. Chapter 3.2. Mechanical ventilation with heat recovery

Part 3 Ancillary technologies. Chapter 3.2. Mechanical ventilation with heat recovery Part 3 Ancillary technologies Chapter CONTENTS SCOPE Clause Page DESIGN Design standards D1 1 Statutory requirements D2 1 System design D3 1 Building integration D4 2 Noise D5 2 Access and controls D6

More information

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion

More information

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system. ROOFTOP - HEAT PUMP UNIT Technical data Applies to Model YNRA R410A This document applies when installing into an air handler or as part of an air handling system. CONTENTS 1. General description... 2

More information

floater imports DF169 ECO AIR COOLER EVAPORATIVE AIR COOLER WITH IONIZER USER S MANUAL

floater imports DF169 ECO AIR COOLER EVAPORATIVE AIR COOLER WITH IONIZER USER S MANUAL floater imports DF169 ECO AIR COOLER EVAPORATIVE AIR COOLER WITH IONIZER USER S MANUAL WHAT IS AN ECO AIR COOLER? The ECO AIR COOLER uses evaporative cooling to provide an airflow that is cooler than the

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support

More information

Spetec. Laminar Flow Box. Portable Clean Room Technology

Spetec. Laminar Flow Box. Portable Clean Room Technology Spetec Laminar Flow Box Portable Clean Room Technology 1 Fundamentals Portable Clean Room Technology Laminar Flow The basis for the development of the clean room technology was first established in the

More information

SAVE ENERGY AT HOME INSULATE AND AIR SEAL

SAVE ENERGY AT HOME INSULATE AND AIR SEAL SAVE ENERGY AT HOME INSULATE AND AIR SEAL Check the roof insulation level and add insulation to maintain minimum R-38 (6 of blown cellulose or equal). Use R-19 between frame or R-10 rigid insulation for

More information

Air Handlers HIGHER PERFORMANCE FOR A HIGHER STANDARD OF COMFORT AND EFFICIENCY. Read Only

Air Handlers HIGHER PERFORMANCE FOR A HIGHER STANDARD OF COMFORT AND EFFICIENCY. Read Only Air Handlers HIGHER PERFORMANCE FOR A HIGHER STANDARD OF COMFORT AND EFFICIENCY. BUILT FOR COMFORT. BUILT FOR YOU. ForeFront Series Air Handlers Our most innovative offering is also our most efficient.

More information

york air-conditioning products Residential & VRF News 2015

york air-conditioning products Residential & VRF News 2015 york air-conditioning products Residential & VRF News 2015 york air-conditioning products Catalogue Content Split Systems Pag. High wall High Efficiency Inverter YWHJZH 09 to 24 K 6 High wall Inverter

More information

Flexit Central Vacuum Cleaner

Flexit Central Vacuum Cleaner Flexit Central Vacuum Cleaner - your choice for a healthier home! Expels harmful fine dust from the house. Norway s best selling! new and improved FOR A HEALTHY INDOOR ENVIRONMENT A healthier home We spend

More information

UR...3 URX CF...7 URHE CF...11. Heat recovery unit. Heat recovery unit with refrigerant circuit(442-1947 cfm)

UR...3 URX CF...7 URHE CF...11. Heat recovery unit. Heat recovery unit with refrigerant circuit(442-1947 cfm) UR...3 Heat recovery unit URX CF...7 Heat recovery unit with refrigerant circuit(442-1947 cfm) URHE CF...11 High efficiency heat recovery unit with refrigeration circuit(588-1942 cfm) UR Heat recovery

More information

NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS PARTS LIST Front Back FIG.5 FIG.6 1. Control panel 2. Carrying handle 3. Water tank 4. Casters

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer

More information

IPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network

IPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network IPThermo206G Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network IPThermo 206G is the central data handling terminal of the IPThermo Pro measurement network. This

More information

BACKGROUND VENTILATION SOLUTIONS FOR DOMESTIC BUILDINGS

BACKGROUND VENTILATION SOLUTIONS FOR DOMESTIC BUILDINGS CI/SfB (57) Uniclass L753 October 2015 BACKGROUND VENTILATION SOLUTIONS FOR DOMESTIC BUILDINGS... PRODUCT RANGE AND OVERVIEW..................................................................................

More information

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA USER S MANUAL FH052EAV1 FH070EAV1 E HNIKA PORTUGUÊS ENGLISH ESPAÑOL ITALIANO DEUTSCH FRANÇAIS System Air Conditioner (Cooling and Heating) E S F I P D G DB98-29263A(1) Safety Precautions Register your

More information

SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION A. The Work specified in this Section consists of designing, furnishing and installing factory-assembled

More information

94122E-05 2005-10 FLEXIT L4 X/TT L7 X/TT. User Manual. Air Handling Unit Loft Models with Heat Recovery

94122E-05 2005-10 FLEXIT L4 X/TT L7 X/TT. User Manual. Air Handling Unit Loft Models with Heat Recovery 94122E-05 2005-10 FLEXIT L4 X/TT User Manual L7 X/TT Air Handling Unit Loft Models with Heat Recovery Contents 1 Important Safety Instructions...3 2 Method of Operation - System...3 3 Operation - Control...4

More information

1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan http://www.fujitsu-general.com/

1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan http://www.fujitsu-general.com/ 1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan http://www.fujitsu-general.com/ ISO 9001 ISO 14001 Certified number : 01 100 89394 Certified number : 01 104 9245101 Fujitsu General (Thailand) Co.,

More information

FilterFlow Automatic Water Boilers. Pure Quality

FilterFlow Automatic Water Boilers. Pure Quality FilterFlow Automatic Water Boilers Pure Quality Filtered hot water on tap Around the world we drink countless millions of cups of tea and coffee each and every day. The consumer s seemingly insatiable

More information

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER. THERMAWAVE CERAMIC HEATER Model HZ-850 Series Model HZ-860 Series IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER. Warning Failure to

More information

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion

More information

Gree Solar Hybrid Hi Wall Inverter Air Conditioner

Gree Solar Hybrid Hi Wall Inverter Air Conditioner Gree Solar Hybrid Hi Wall Inverter Air Conditioner Utilize the natural power of the sun to heat or cool your home. Find out more at www.greeonline.com Why Choose a Solar Hybrid Inverter? The new Gree Solar

More information

Air conditioning unit Saphir vario. 2. Product information for the new Truma air conditioning unit. Comfort on the move

Air conditioning unit Saphir vario. 2. Product information for the new Truma air conditioning unit. Comfort on the move Air conditioning unit 2. Product information for the new Truma air conditioning unit October 2006 Edition Comfort on the move Air conditioning systems Manoeuvring systems Energy systems Heating systems

More information

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009 Climasys Thermal Management System Schneider Electric Universal Enclosures 2009 Schneider Electric Universal Enclosures The specialist in sealed equipment What is the mission of Schneider Electric Universal

More information

Element D Services Heating, Ventilating, and Air Conditioning

Element D Services Heating, Ventilating, and Air Conditioning PART 1 - GENERAL 1.01 OVERVIEW A. This section supplements Design Guideline Element D3041 on air handling distribution with specific criteria for projects involving design of a Data Center spaces B. Refer

More information

Installation and maintenance instructions. Danfoss Vent

Installation and maintenance instructions. Danfoss Vent Installation and maintenance instructions Danfoss Vent 1 Unit design... 2 2 Project planning and installation instructions... 3 2.1 Ventilation...3 2.2 Piping installation....3 2.3 Condensation line...4

More information

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control Short Form Catalogue Alarm Systems Reliable Supervision and Control Alarm Monitors and Indicators The SELCO product range includes a number of alarm monitors and indicator panels for use in numerous applications.

More information

- White Paper - Data Centre Cooling. Best Practice

- White Paper - Data Centre Cooling. Best Practice - White Paper - Data Centre Cooling Best Practice Release 2, April 2008 Contents INTRODUCTION... 3 1. AIR FLOW LEAKAGE... 3 2. PERFORATED TILES: NUMBER AND OPENING FACTOR... 4 3. PERFORATED TILES: WITH

More information