1 Cable Network Transparency Fiber Optic Monitoring Fault recognition, localisation and reporting
2 Fiber Optic Cable Future of Telecommunication The demand for complex fiber optic cable networks and flexible IP data traffic increases exponentially concurrently with the demand for network services - thus requiring constant and high transfer rates. An efficient fiber optic cable monitoring is essential for succeeding in this aim - made by LANCIER Monitoring. Fiber Optic Cable Monitoring is essentialy required Fiber optic cable has unexpectedly turned out to be sensitive to environmental influences. For example penetrating humidity is influencing the transmission quality. Ruptures due to ground movements, construction works or even theft may cause total loss. Thus fiber optic cables must be monitored as well. The transmission quality over the entire cable is measured using attenuation values in a reference fiber. In this process state-of-the-art sensor technology results in quick and precise fault detection. The LANCIER Monitoring Fiber Optic Monitoring System offers to you permanent preventive monitoring, short response time when faults occur = no or only short down times, fault location if reflectometer (OTDR) is implemeted in the monitoring system, Top-quality OTDRs (Optical Time Domain Reflectometers) are used to point the fault location precisely. OTDRs tailored to the relevant transmission wavelength are em - ployed as the particular task dictates. 2 monitoring of active and dark fibres, monitoring of optical performance, monitoring of optical attenuation, monitoring using reflectometers (OTDR), monitoring for humidity penetration.
3 OTDR The core of Fault Location at Optic Fibers Embedding an OTDR with optical switch into the RTU upgrades the Unified Monitoring System (UMS) to a precise fiber optic fault-location system. The use of optical switches allows for the monitoring of an almost unlimited number of optic fibers which are measured consecutively. Even dark fibers might be monitored due to the application of WDM (wavelength division multiplexers). IP network Optical switch OTDR (Optical Time Domain Reflectometer) RTU The UMS reads the attenuation characteristics periodically, evaluates them and reports significant changes. In the process it indicates the precise position of the faulty spot on the monitored fiber route. Linked to a GIS database the UMS can determine the exact geographical position. Typical back-scattering trace of an optic fiber 3
4 Optical Loss Monitoring provides Security The FiberTxA-Mk2 is a stand-alone measurement and monitoring device for dark and active optical fibers. Loop or serial measurements are continuously executed on a spare optical fiber. The thresholds for the attenuation values are easily programmable with the built-in keys. The integrated display shows the measurement values and settings. Loop Measurement of a fiber optic pair Monitoring the optical attenuation detects breaks and kinks of dark fibers humidity ingress - in conjunction with the AquaSensor (only at 1625 nm, see rear page) security breaches through tapping with bending couplers (only at 1625 nm) Fiber optic pair Serial Measurement of an optic fiber Fiber optic trunk cable 4
5 Optical Power Monitoring provides a general Survey Active optical fibers are monitored for changes of the optical power with the OpTxA- Mk2. Thresholds are easily programmable with the built-in keys. The integrated display shows the measurement values and settings. Especially when combined with an OTDR-based monitoring system an all-inclusive surveillance of dark and active fibers can be realised very economically. Monitoring the optical power determines the optical power at the receiver site. Reduced power suggests a cable fault (increased attenuation) or reduced transmitter power. allows for the quickest possible alarm notification with fault localization in hybrid systems in conjunction with an OTDR. Serial Measurement of an optic fiber Fiber optic trunk cable Optical receiver Optical emitter LANCIER Monitoring Mk2-Sensors are equipped with dry output relay contacts to allow for remote alarming. Additionally they can be supplied with plug-in interface modules for the LANCIER Tx-Bus or CAN-Bus in order to integrate them into the Unified Monitoring System (UMS). 5
6 PON - Passive Optical Network Economic and convenient Surveillance In order to cope with the increasing demand of bandwidth due to new applications like triple-play more and more network providers choose to facilitate PON (Passive Optical Network) technology. This Point-to-multiplepoint (P2MP) topology supplies up to 128 subscribers with broadband access through a single fiber. To achieve this a passive splitter is used to distribute the downstream signal sent from OLT Splitter the central office (exchange) to the subscribers. At the user site only the dedicated signal for the particular subscriber is decoded and supplied. In the opposite direction it is common to use time or wavelength multiplex methods to avoid collisions of the transmitted data. Cable monitoring all the way to the subscriber Exact fault localization between OLT and splitter Time and cost saving through instant alarming and localization PON monitoring External Services NMS (Network Management System) Cable management system GIS (Geographical Information System) SMS Fax Pager... Report 6 Server
7 The LANCIER Monitoring system for PON is compact and modular. The RTU (Remote Testing Unit) is installed in the central office (exchange). The built-in high-end OTDR comes with three measurement wavelengths (1310 nm, 1550 nm and 1625 nm) to be prepared for any measurement task and stateof-the-art deadzones, which makes PON monitoring possible in the first place. An optical switch with the necessary amount of fiber connectors sequentially attaches the fibers to be measured to the OTDR. If the transmission equipment installed in the central office is not already equipped with monitoring channels, additional wave division multiplexers (WDM) are used to couple the monitoring signal into the active fibers. The OTDR then measures the fiber even past the passive splitter all the way down to the s (subscriber site). During the measurement the end reflection is evaluated to determine whether the connection between splitter and is still fully functional. Additionally an exact fault localization between the OLT and the splitter is possible, which saves even more time for the diagnostics. Splitter Splitter PON Splitter Splitter WDM... WDM WDM... WDM OLT IP network (Optical line terminal) Optical switch OTDR (Optical Time Domain Reflectometer) RTU Client 7 WDM = wavelength division multiplexers to couple in the monitoring signal = Optical Network Unit (end user)
8 Humidity threatens Optic Fibers The AquaSensor is the remedy Water penetrating into splicing boxes, e.g. through damage of the sleeve, imperfect sealing or a defective cable sheath, embrittles the fiber optic cable and causes microcracks. In the long term, this leads to deterioration of the fiber properties or even to an unexpected total loss of signal transmission. The reliably working LANCIER AquaSensor early-warning system helps to ob viate these consequences. If the AquaSensor comes into contact with humidity, the fiber is bent in a controlled way to generate a measurable increase of attenuation. These changes can be shown as graphic representation using the LANCIER Monitoring System. The LANCIER AquaSensor can be inserted into all current splice holders, and no metallic conductor is AquaSensor required for signalling. A LANCIER FiberTxA-Mk2 sensor or an OTDR are required to read the AquaSensor. The LANCIER AquaSensor reports humidity and water penetration into fiber optic joints, has short response times, allows for exact fault localisation by the UMS, is re-usable after fault report due to the reversible behaviour of the humidity measuring tape, can be mounted quickly and easily into the splice holder. AquaSensor mounted in a splicing box LANCIER Monitoring GmbH Gustav-Stresemann-Weg Münster, Germany Tel. +49 (0) Fax +49 (0) Ko/11.10 Alterations reserved.
Cable Network Transparency Unified Monitoring System UMS
Cable Network Transparency Unified System UMS Fault recognition, localisation and reporting UMS Universal cable network and equipment monitoring cable networks and associated equipment used to be considered
More informationGraphical User Interface Capabilities of MATLAB in Centralized Failure Detection System (CFDS)
INTERNATIONAL JOURNAL OF MICROWAVE AND OPTICAL TECHNOLOGY 128 Graphical User Interface Capabilities of MATLAB in Centralized Failure Detection System (CFDS) Mohammad Syuhaimi Ab-Rahman* and Boonchuan Ng
More informationTROUBLESHOOTING AT THE SPEED OF LIGHT EMBEDDED OTDR FOR OPERATIONAL EXCELLENCE IN PASSIVE OPTICAL NETWORKS
TROUBLESHOOTING AT THE SPEED OF LIGHT EMBEDDED OTDR FOR OPERATIONAL EXCELLENCE IN PASSIVE OPTICAL NETWORKS Application Note Abstract With our increasing dependence on broadband, service disruptions are
More informationOptical Network Management System. Remote Testing, Network Monitoring, and Service Provisioning Solution for High-Quality Network Performance
Optical Network Management System Remote Testing, Network Monitoring, and Service Provisioning Solution for High-Quality Network Performance JDSU Enabling Broadband and Optical Innovation Improving the
More informationONMSi: Optical Network Monitoring System. Fiber Network Visibility that Scales for Both PON and Point-to-Point Networks
ONMSi: Optical Network Monitoring System Fiber Network Visibility that Scales for Both PON and Point-to-Point Networks y Drastically reduce network downtime y Improve network reliability and SLA management
More informationHow To Use Onmsi For Fiber Optic Network Monitoring System
ONMSi: Optical Network Monitoring System Fiber network visibility that scales for both PON and point-to-point networks Drastically reduce network downtime Improve network reliability and SLA management
More informationInterceptor Optical Network Security System. Design Guide. Chapter 4: INTERCEPTOR Optical Network Security System Alarmed Carrier PDS
Interceptor Optical Network Security System } Chapter 4: INTERCEPTOR Optical Network Security System Alarmed Carrier PDS Copyright 2010 Network Integrity Systems, Inc. All rights reserved. The information
More informationMTS/T-BERD Platforms Very Long Range (VLR) OTDR Module
COMMUNICATIONS TEST & MEASUREMENT SOLUTIONS MTS/T-BERD Platforms (VLR) OTDR Module Key Features CWDM/DWDM ready with 1310, 1383, 1490, 1550, and 1625 nm wavelengths FTTx ready with 1310/1490/1550 nm wavelengths
More informationLive Fiber Monitoring in CWDM Networks
Live Fiber Monitoring in CWDM Networks Olivier Plomteux, Senior Product Line Manager, Optical Business Unit To cope with the signifi cant increase for storage and on-demand delivery of digital content,
More informationONMSi: Optical Network Monitoring System
ONMSi: Optical Network Monitoring System Fiber network visibility that scales for both PON and point-to-point networks Drastically reduce network downtime Improve network reliability and SLA management
More informationFIBER OPTIC SYSTEM TEST PROCEDURES
FIBER OPTIC SYSTEM TEST PROCEDURES Data Systems Performance Engineering LLC performs three tests in order to determine fiber optic cable adequacy. The order in which the tests are to be performed is not
More informationDIRECTIONAL FIBER OPTIC POWER MONITORS (TAPS/PHOTODIODES)
Features: DIRECTIONAL FIBER OPTIC POWER MONITORS (TAPS/PHOTODIODES) PATENT NUMBERS: CANADA 2,494,133, USA 7095931, 7295731 AND CHINA 1672073 Telcordia GR-468 qualified Available in versions for any wavelength
More informationMultiplexing. Multiplexing is the set of techniques that allows the simultaneous transmission of multiple signals across a single physical medium.
Multiplexing Multiplexing is the set of techniques that allows the simultaneous transmission of multiple signals across a single physical medium. The following two factors in data communications lead to
More informationLine Monitoring and Control in Subsea Networks
Line Monitoring and Control in Subsea Networks This paper discusses how submerged equipment is monitored and contrasts different methods of doing this. It also considers what features are required by the
More informationBroadband 101: Installation and Testing
Broadband 101: Installation and Testing Fanny Mlinarsky Introduction Today the Internet is an information superhighway with bottlenecks at every exit. These congested exits call for the deployment of broadband
More informationPerformance Management and Fault Management. 1 Dept. of ECE, SRM University
Performance Management and Fault Management 1 Dept. of ECE, SRM University Performance Management Performance management requires monitoring of the performance parameters for all the connections supported
More informationCabling & Test Considerations for 10 Gigabit Ethernet LAN
Introduction Current communication data rates in local networks range from 10/100 megabits per second (Mbps) in Ethernet to 1 gigabit per second (Gbps) in fiber distributed data interface (FDDI) and Gigabit
More informationComprehensive geospatial network management based on MapInfo. Supporting both physical and logical network resource management
Comprehensive geospatial network management based on MapInfo Supporting both physical and logical network resource management ConnectMaster is an open, integratable, scalable software solution for the
More informationModule 13 : Measurements on Fiber Optic Systems
Module 13 : Measurements on Fiber Optic Systems Lecture : Measurements on Fiber Optic Systems Objectives In this lecture you will learn the following Measurements on Fiber Optic Systems Attenuation (Loss)
More informationFiber Characterization Service
About JDSU JDSU s verifies the integrity and capacity of your fiber plant through the measurement of key fundamental properties, such as attenuation, reflectance, and dispersion. Comprehensive testing,
More informationDetecting faulty fiber with centralized failure detection system (CFDS) in fiber-to-the-home (FTTH) access network
Optica Applicata, Vol. XXXIX, No. 2, 2009 Detecting faulty fiber with centralized failure detection system (CFDS) in fiber-to-the-home (FTTH) access network MOHAMMAD SYUHAIMI AB-RAHMAN *, BOON CHUAN NG,
More informationRemoving the Mystery from OTDR Measurements. Keith Foord Product Manager Greenlee Communications
Removing the Mystery from OTDR Measurements Keith Foord Product Manager Greenlee Communications Why an OTDR? Terminology Theory Standards Key specifications Trade-offs Cleaning and Inspection Measurements
More informationGigabit Passive Optical Networks
White Paper Gigabit Passive Optical Networks Passive Optical LAN Solutions (POLS) Theory, Design, and Installation Considerations Sean McCloud, RCDD Senior Applications Engineer, Leviton Network Solutions
More informationINTERNATIONAL TELECOMMUNICATION UNION SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT
INTERNATIONAL TELECOMMUNICATION UNION ITU-T L.52 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (05/2003) SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT
More informationConstruction of High-speed and High-reliability Optical Networks for Social Infrastructure
Hitachi Review Vol. 59 (Feb. 2010) 1 Construction of High-speed and High-reliability Optical Networks for Social Infrastructure Ryosuke Nishino Hideaki Tsushima, Dr. Eng. Eisuke Sato Shinsuke Tanaka OVERVIEW:
More informationCADDSTAR V7.0 FEATURES AND FUNCTIONALITY
CADDSTAR V7.0 FEATURES AND FUNCTIONALITY CADDStar is a powerful GIS-based facilities management and network documentation software. By combining the drawing / mapping features of AutoCAD Map with a relational
More informationCCNA Discovery Chapter Four
CCNA Discovery Chapter Four By Chief Eng. Amna Ahmed Institute of Telecommunication amna_ahmed28@yahoo.com Modified by Vincenzo Bruno Hacklab Cosenza Chapter 4 Explain what the internet is Every day millions
More informationCable 101. A Broadband Telecommunications Primer for Non-technical Personnel
Cable 101 KnowledgeLink, Inc. A Broadband Telecommunications Primer for Non-technical Personnel Presented by: Justin J. Junkus President, KnowledgeLink, Inc. November 20, 2013 Agenda Broadband Cable Systems
More informationUSE OF FIBRE OPTICS INTERNATIONAL STANDARDS FOR CALIBRATION LABORATORY ACCREDITATION INTERNATIONAL ELECTROTECHNICAL COMMISSION
USE OF FIBRE OPTICS INTERNATIONAL STANDARDS FOR CALIBRATION LABORATORY ACCREDITATION INTERNATIONAL ELECTROTECHNICAL COMMISSION USE OF FIBRE OPTICS INTERNATIONAL STANDARDS FOR CALIBRATION LABORATORY ACCREDITATION
More informationIPv6 Broadband Access Network Systems
IPv6 Broadband Access Network Systems IPv6 Broadband Access Network Systems 60 Junji Yamada Koji Wakayama Eisuke Sato OVERVIEW: To meet the demand for broadband access and enable a smooth transition from
More informationMeasuring of optical output and attenuation
Measuring of optical output and attenuation THEORY Measuring of optical output is the fundamental part of measuring in optoelectronics. The importance of an optical power meter can be compared to an ammeter
More informationFiber-to-the-Home/FTTH
Hands-On Design, Installation, Maintenance & Troubleshooting Active and Passive Optical Networks Course Description This Hands-On 2-day course is designed to provide technicians with Hands-On practical
More informationWDM Passive Optical Networks: Protection and Restoration
OECC 2009 Workshop: Next-generation Broadband Optical Access Future Challenges Session 1: Broadband Network Architectures, WDM PON Evolution Strategies and Future Ultra-high- bandwidth Services WDM Passive
More informationFiber Optics and Liquid Level Sensors Line Guide
Fiber Optics and Liquid Level Sensors Line Guide Excellence, through every fiber. Honeywell Sensing and Control (S&C) offers fiber optic sensors manufactured with SERCOS (Serial Real-time Communication
More informationH-NW-1 H-NW-2 H-NW-3 H-NW-4 H-NW-5 H-NW-6. Reliability Management of Telecommunication Networks by Analyzing Outage Data
Technologies for establishing a base network infrastructure including optical networks, wireless and satellite, all of which are essential to guaranteed bandwidth and broadband telecommunication. H-NW-1
More informationDistributed Temperature Monitoring of Energy Transmission and Distribution Systems
1 m 40000m0 range 61850 IEC spatial resolution Distributed Temperature Monitoring of Energy Transmission and Distribution Systems Ensuring a Reliable Supply of Electrical Power for Today s World www.en-sure.pro
More informationSECTION 16715 TELECOMMUNICATIONS ACCEPTANCE TESTING
PART 1 - GENERAL 1.1 SECTION INCLUDES A. Testing Publications and Standards B. Inspection and testing procedures for copper and fiber optic cable, RF CATV / MATV systems, and the antenna systems. C. Documentation
More informationHow To Build A Network For Storage Area Network (San)
White Paper Data Storage across the MAN by deploying a SAN over Dark Fiber by Pieter Panis, EuroFiber 1/7 1 Introduction The purpose of this document is to illustrate how a storage area network (SAN) can
More informationELM Security System Electronic Locking & Monitoring
Whitepaper ELM Security System Electronic Locking & Monitoring Issue: September 2006 EMKA Beschlagteile GmbH & Co.KG Release: 1.0 Langenberger Str. 32 42551 Velbert Germany Tel.: 0049 (0) 20 51 / 2 73-0
More informationSecurity & Surveillance Cabling Systems
Security & Surveillance Cabling Systems Security and Surveillance Cabling Systems The video security industry is growing and ever-changing, offering a wealth of opportunity for today s security professionals.
More informationOptical Submarine Cable Network Monitoring Equipment
Optical Submarine Cable Network Monitoring Equipment NOMURA Kenichi, TAKEDA Takaaki Abstract The introduction of large-capacity wavelength-division multiplexing and OADM (Optical Add/Drop Multiplexing)
More informationOptical Fiber Data Center Field Testing. ANSI/BICSI 002-2011 Data Center Design and Implementation Best Practices
Optical Fiber Data Center Field Testing ANSI/BICSI 002-2011 Data Center Design and Implementation Best Practices Abstract Data Centers are a growing segment of the enterprise market. Regardless of whether
More informationSolution Main Functions Continuous 24/7 fibre quality monitoring Scheduled OTDR proactive maintenance testing Remote trouble-shooting The Package
NQMSfiber The Fibre Monitoring Solution NQMSfiber What Does It Do? Solution Main Functions Continuous 24/7 fibre quality monitoring Scheduled OTDR proactive maintenance testing Remote trouble-shooting
More informationOptimux-134, Optimux-125
Data Sheet Optimux-134, Optimux-125 Up to 16 E1/T1 links, full bandwidth 100 Mbps Ethernet traffic and high-speed data multiplexed into fiber optic uplink 25/34 Mbps or 125/134 Mbps operation s Single-,
More informationDesign Guide. SYSTIMAX InstaPATCH 360 Traffic Access Point (TAP) Solution. www.commscope.com
Design Guide SYSTIMAX InstaPATCH 360 Traffic Access Point (TAP) Solution www.commscope.com Contents Introduction 3 How Does a TAP Work? 3 The TAP Ecosystem 4 InstaPATCH 360 TAP Module Family 4 InstaPATCH
More informationThe Optical Submarine Repeater and Its Associated Technologies
The Optical Submarine Repeater and Its Associated Technologies YAMAGUCHI Shohei, MIKAMI Satoshi, AIDA Ryuji, NAGASAWA Toshihide Abstract The key to meeting the increasing needs of submarine cable systems
More informationIntroduction to Optical Networks
Yatindra Nath Singh Assistant Professor Electrical Engineering Department Indian Institute of Technology, Kanpur Email: ynsingh@ieee.org http://home.iitk.ac.in/~ynsingh 1 What are optical network? Telecomm
More informationFOA Technical Bulletin. Guide To Fiber Optic Network Restoration
The Fiber Optic Association, Inc. 1119 S. Mission Road #355, Fallbrook, CA 92028 1-760-451-3655 Fax 1-781-207-2421 Email: info@thefoa.org http://www.thefoa.org FOA Technical Bulletin Guide To Fiber Optic
More informationCompetition for consumer voice,
The Impact of Automated Fiber Management on FTTH Deployment and Operations A new technology, automated fiber management, simplifies the deployment of fiber to the home, yielding potentially great savings
More informationModularized and Multi-Functional Power Distribution for Cabinets 3.01
Modularized and Multi-Functional Power Distribution for Cabinets 3.01 1 1 Intelligent Data Center Solutions for Networks of the Future Hexatronic offers reliable, high quality data center solutions designed
More informationWDM-PON: A VIABLE ALTERNATIVE FOR NEXT GENERATION FTTP
WDM-PON: A VIABLE ALTERNATIVE FOR NEXT GENERATION FTTP AN ENABLENCE ARTICLE WRITTEN BY DR. MATT PEARSON, VP TECHNOLOGY PUBLISHED IN FTTH PRISIM MAGAZINE March, 2010 www.enablence.com Most of the Fiber-to-the-Home
More informationAn advanced Dark Fiber Monitoring System for Next Generation Optical Access Networks
An advanced Dark Fiber Monitoring System for Next Generation Optical Access Networks Min Cen, Jiajia Chen, Véronique Moeyaert, Patrice Mégret and Marc Wuilpart 18th Annual Workshop of the IEEE Photonics
More informationHow To Get The Most Out Of A Pon From Commscope
Passive Optical Network (PON): Solutions for Federal Government Deployments Operational Efficiency Solutions Passive Optical Network (PON) solutions for federal government networks Discover opportunities
More informationFALCO. Broadband Groomer. F-330 Series. Applications. Access system for:
Broadband Groomer F-330 Series Falco is the industry first Access Unit designed to offer access to SDH/SONET/PDH backbones by different. extends the usefulness of WAN/LAN to and GbE backbones. Falco combines
More informationPASSIVE WDM COMPONENTS: COUPLERS
PASSIVE WDM COMPONENTS: COUPLERS 200714007 EREN CANDAŞ 200714017 BERK EROL Supervisors: Halil Tanyer EYYUBOĞLU Mehmet Eray METİN (Türk Telekom) Presentation Outline Introduction Project Plan Group Study
More informationGenexis FTTH Network Architecture
Genexis FTTH Network Architecture An introduction to the Genexis FTTH Network Architecture This document contains general information about the Genexis FTTH Network Architecture. Contents 1. Introduction...2
More informationCable Management. Stay in control full insight into inside & outside plant management ensures. that you stay on top of cable management.
Cable Management Stay in control full insight into inside & outside plant management ensures that you stay on top of cable management. www.fntsoftware.com Global mobile data traffic will increase nearly
More informationOptimux-34, Optimux-25
Data Sheet Optimux-34, Optimux-25 Up to 16 E1/T1 links and high-speed data or Ethernet traffic multiplexed into fiber optic uplink E3 copper uplink for Optimux-34 Single-mode, multimode, single-mode over
More informationTroubleshooting and Auto-Negotiation Features for IMC Networks Media Conversion Products
Troubleshooting and Auto-Negotiation Features for IMC Networks Media Conversion Products Table of Contents Introduction...................................................................... 1 About Link
More informationResolution of comments 242 and 267 on Insertion loss measurements of installed fiber cables. Steve Swanson May 5, 2009
Resolution of comments 242 and 267 on Insertion loss measurements of installed fiber cables Steve Swanson May 5, 2009 Current text in 86.10.1 Insertion loss measurements of installed fiber cables are made
More informationOptical network diagnostics capabilities for meeting high level Services
Optical network diagnostics capabilities for meeting high level Services S ervice Line Agreements (SLA) are one of the key operating necessities for telecom service providers. Using different levels of
More informationWhite Paper: 10GbE Fiber A Practical Understanding and Functional Approach
White Paper: 10GbE Fiber A Practical Understanding and Functional Approach Dennis Manes, RCDD Senior Applications Engineer Leviton Network Solutions E/8 #2509 Table of Contents Introduction 3 Types of
More informationIntroduction to Add-Drop Multiplexers
3 Introduction to Add-Drop Multiplexers In this chapter different channel routing technologies are reviewed, highlighting the advantages and drawbacks of the different devices and configurations. The parameters
More informationWaveReady CFM. Optical Link Monitoring System: Continuous Fiber Monitor
WaveReady CFM Optical Link Monitoring System: Continuous Fiber Monitor www.lumentum.com Data Sheet The Lumentum Continuous Fiber Monitor (CFM) offers a compact, modular solution for performance monitoring
More informationCable TV Headend Solutions
Product Family DVX Platform Cable TV Headend Solutions The DVX platform TELESTE DVX is a complete solution for digital and analogue broadcasting infrastructures for cable operators. The offering includes
More informationCISCO WDM SERIES OF CWDM PASSIVE DEVICES
DATA SHEET CISCO WDM SERIES OF CWDM PASSIVE DEVICES Cisco Systems introduces its second generation of coarse wavelength-division multiplexing (CWDM) passive devices boasting increased functions and improved
More informationWhat testing is required for PREMISES Fiber Optic Cabling and the standards used
Testing Cabling in the Data Center Part 1 Fiber Testing Wayne Allen Product Marketing Engineer Asia Pacific Region Fluke Networks In this presentation What testing is required for PREMISES Fiber Optic
More informationInstruction Manual RT-94845SL RR-94845SL Forty-Eight Channel Video Multiplexer With Bi-directional Ethernet Data
Instruction Manual RT-94845SL RR-94845SL Forty-Eight Channel Video Multiplexer With Bi-directional Ethernet Data Copyright 2007, American Fibertek, Inc. 0411JD Table of Contents Functional Description...3
More informationTesting a Real Time Monitoring System for Passive Optical Networks using an Array of Fiber Bragg Gratings
Testing a Real Time Monitoring System for Passive Optical Networks using an Array of Fiber Bragg Gratings a Abdosllam M. Abobaker, a Issa Eldbib, a Abdulaziz Hasen Daw, and b P. Ramesh Babu a Department
More informationpalmotdr Series Handheld OTDR
palmotdr Series Handheld OTDR Most Compact High-Performance OTDR Comprehensive fiber applications, ideal for LAN/WAN/FTTx certification & trouble-shooting: SM: 1310/1490/1550, 1625/1650nm (with filter),
More informationDomain 5.0: Network Tools
ExamForce.com CompTIA Network+ N10-004 Study Guide 1 Domain 5.0: Network Tools Chapter 5 5.1 Given a scenario, select the appropriate command line interface tool and interpret the output to verify functionality
More informationOptimux-134, Optimux-125
Optimux-134, Optimux-125 Up to 16 E1/T1 links, full bandwidth 100 Mbps Ethernet traffic and high-speed data multiplexed into fiber optic uplink 34/25 Mbps or 134/125 Mbps operation s Single-, multi, single-
More informationData Center Design for 40/100G
Data Center Design for 40/100G With the continued requirement for expansion and scalability in the data center, infrastructures must provide reliability, manageability and flexibility. Deployment of an
More informationPower Feeding Equipment for Optical Submarine Cable Systems
Power Feeding Equipment for Optical Submarine Cable Systems KANEKO Tomoyuki, CHIBA Yoshinori, KUNIMI Kaneaki, NAKAMURA Tomotaka Abstract A submarine cable system is fed power from power feeding equipment
More informationThe Economics of Broadband Access Platform Evolution
The Economics of Broadband Access Platform Evolution The EU's ACTS (Advanced Communications Technologies and Services) research programme has tested a number of approaches to delivering broadband services
More informationOptimux-45, Optimux-45L Multiplexers for 21E1/28T1 over Fiber or T3
Data Sheet Optimux-45, Optimux-45L Up to 28 T1 or 21 E1 channels multiplexed into a single 45 Mbps data stream Any Traffic over Fiber Combination of T1 and E1 channels Transmission over coax or fiber optic
More informationFundamentals of Telecommunications
Fundamentals of Telecommunications Professor of CIS Columbus, OH 43210 Jain@ACM.Org http://www.cis.ohio-state.edu/~jain/ 1 Overview Time Division Multiplexing T1, T3, DS1, E1 T1 Framing Echo Cancellation
More informationHow To Define Hfc Technology
Cable network topologies and implications for evolutionary approaches 33 rd International conference and Exhibition PIKE 2008, Zakopane, 14 October 2008 Bart Brusse, ReDeSign Project Manager Pressure on
More informationFTTH ARCHITECTURE WHITE PAPER SERIES
Not all FTTH networks are built the same. Since construction and outside plant account for the majority of total network costs, getting the architecture right has a major impact on the business case. The
More informationOFM-500 Optical Fiber Mapping Software. A complete software application for managing documentation in fiber optic plants
OFM-500 Optical Fiber Mapping Software A complete software application for managing documentation in fiber optic plants OFM-500 Optical Fiber Mapping (OFM) Software Designed by fiber optic engineers for
More informationbest Practices for troubleshooting WDm networks with an optical spectrum analyzer by Jean-Sébastien Tassé, Product Line Manager, EXFO
best Practices for troubleshooting WDm networks with an optical spectrum analyzer by Jean-Sébastien Tassé, Product Line Manager, EXFO the challenge Most telecom operators are facing a growing demand for
More informationFiber to the Home. Definition. Overview. Topics
Fiber to the Home Definition Fiber to the home (FTTH) is the ideal fiber-optics architecture. In this architecture, fiber deployment is carried all the way to the customer s home (premises). Overview Today
More informationENGINEERING COMMITTEE Construction and Maintenance Subcommittee
z ENGINEERING COMMITTEE Construction and Maintenance Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 87-1 2003 (formerly CMS WG6-0001) Graphic Symbols For Cable Telecommunications Part 1: HFC Symbols
More informationSection 16935 TELEPHONE AUTOMATIC DIALER SYSTEM
Section TELEPHONE AUTOMATIC DIALER SYSTEM PART 1 GENERAL 1.01 SYSTEM DESCRIPTION A. Design Requirements: 1. Electronic monitoring system shall interface plant alarms to public telephone system or cellular
More informationGuidelines. LANscape Solutions Recommended Fiber Optic Test Guidelines. Table of Contents. 1. Introduction. 2. Why Test? 1. Introduction...
LANscape Solutions Recommended Fiber Optic Test Guidelines Table of Contents 1. Introduction...1 2. Why Test?...1 3. Tier 1 and Tier 2 Testing...2 4. Encircled Flux...3 5. Link-Loss Budgets...4 6. Proper
More informationActerna OFS-100/-200. Optical results analysis & cable acceptance report generation software ACTERNA TEST & MEASUREMENT SOLUTIONS
ACTERNA TEST & MEASUREMENT SOLUTIONS Acterna OFS-100/-200 Optical results analysis & cable acceptance report software Key Features OFS-100 OTDR, CD, PMD, AP, ORL and OSA results analysis Batch processing
More informationTransPacket white paper. CWDM and DWDM networking. Increasing fibre-optical network utilization and saving on switches/routers 28.06.
TransPacket white paper CWDM and DWDM networking 28.06.2011 Increasing fibre-optical network utilization and saving on switches/routers Executive summary From being primarily a technology for transport
More informationHow To Sell A Talan
The TALAN represents state-of-the-art capability to rapidly and reliably detect and locate illicit tampering and security vulnerabilities on both digital and analog telephone systems. Marketing Characteristics
More informationCable Modems. Definition. Overview. Topics. 1. How Cable Modems Work
Cable Modems Definition Cable modems are devices that allow high-speed access to the Internet via a cable television network. While similar in some respects to a traditional analog modem, a cable modem
More information25 Years of Manufacturing Excellence. Premier Quatro Addressable Fire Alarm System. Assessed to ISO 9001: 2008
Premier Quatro Addressable Fire Alarm System Premier Quatro 4 Loop Analogue Addressable Fire Alarm Panel The Premier Quatro is the new 4 loop analogue Alarm Systems. It is available in 1, 2, 3 or 4 loop
More informationFiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers
Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers Analog Data Links Multi-Channel Contact Closures Multiplexers Digital Data Links - Contact Closures Power Supply
More informationCONDIS. IT Service Management and CMDB
CONDIS IT Service and CMDB 2/17 Table of contents 1. Executive Summary... 3 2. ITIL Overview... 4 2.1 How CONDIS supports ITIL processes... 5 2.1.1 Incident... 5 2.1.2 Problem... 5 2.1.3 Configuration...
More informationRecession-Proof Consulting Services with CWDM Network Design
Recession-Proof Consulting Services with CWDM Network Design Presented By Ty Estes Marketing Communications Director Omnitron Systems Recession-Proof Consulting Services with CWDM Network Design Introduction
More informationS a f e G u i d a n c e. Single Lamp Control and Monitoring
Single Lamp Control and Monitoring S a f e G u i d a n c e Separation brings Benefits Traditionally designed power supplies for airfield lighting systems require separate series circuits when switching.
More informationE-Option Multi-taps Conditioning at the Tap
E-Option Multi-taps Conditioning at the Tap (actual size) Introduction Traditional Cable Television Systems had long been associated with one-way downstream signal transmissions that provide video services
More informationComputers Are Your Future. 2006 Prentice-Hall, Inc.
Computers Are Your Future 2006 Prentice-Hall, Inc. Computers Are Your Future Chapter 3 Wired and Wireless Communication 2006 Prentice-Hall, Inc Slide 2 What You Will Learn... ü The definition of bandwidth
More informationNexus Technology Review -- Exhibit A
Nexus Technology Review -- Exhibit A Background A. Types of DSL Lines DSL comes in many flavors: ADSL, ADSL2, ADSL2+, VDSL and VDSL2. Each DSL variant respectively operates up a higher frequency level.
More informationSTATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 804 FIBER OPTIC CABLE FOR TRAFFIC SIGNAL INTERCONNECT JANUARY 19, 2007
804.01 Description 804.02 General 804.03 Materials 804.04 Fan-Out Kit 804.05 Drop Cable 804.06 Fiber Optic Patch Cord 804.07 Termination Panel 804.08 Fusion Splice 804.09 Fiber Optic Connector 804.10 Splice
More informationF2400 FOM II Series Fiber Optic Modem Technical Manual
F2400 FOM II Series Fiber Optic Modem Technical Manual T1 Revision B Copyright April 2003 VERSITRON, Inc. 83 Albe Drive / Suite C Newark, DE 19702 www.versitron.com A030430283T PROPRIETARY DATA All data
More informationINTRODUCTION TO MEDIA CONVERSION
WHITE PAPER INTRODUCTION TO MEDIA CONVERSION Table of Contents Introduction 1 What is a Media Converter? 1 Advantages of Media Conversion Technology 1 Benefits of Fiber Optic Cabling 2 Types of Media Converters
More information