Cable Network Transparency Unified Monitoring System UMS

Size: px
Start display at page:

Download "Cable Network Transparency Unified Monitoring System UMS"

Transcription

1 Cable Network Transparency Unified System UMS Fault recognition, localisation and reporting

2 UMS Universal cable network and equipment monitoring cable networks and associated equipment used to be considered an isolated task. Modern management systems, however, require integration of the various monitoring tasks to make efficient quality assurance and service management feasible. LANCIER's Unified System integrates all services and incorporates flexible reporting and a TMN interface. Fiber Optic Network Fiber with OTDR Optical Power Optical Loss Copper Cable Network External Services TMN (Telecommunication Management Network) Cable Management System 2 GIS (Geographical Information System)

3 The LANCIER UMS monitoring system permits permanent preventive monitoring, rapid reaction to faults, = no or only brief down times, and troubleshooting. UMS components The is the universal platform for all network and equipment monitoring tasks. It collects the parameters to be measured and evaluates the measured values as well according to the programmed thresholds. Alarms and condition information are always accessible via the central server over the network. The server includes the central Oracle TM database for all s and stores information and data for clients. /server communication uses the Internet protocol and can hence be via Internet or Intranet using standard browsers. The client displays the current measurement and network data along with their condition. Graphic display of fault sites with GIS coordinates and mapping is feasible. Plants and Systems Insulation Pressurisation Humidity inside Sleeves... Physical Parameters: Pressure, Humidity, Temperature... Contactors Access Control... SMS Fax Pager... Report Server 3

4 Fiber Optic Network fiber optic cables keeps you abreast of their current condition. Environmental influences such as humidity penetrating the cables may harm transmission quality. Cracks, earth movements, building work and theft may cause complete breakdown. Transmission quality over the entire path is determined using attenuation and/or performance values for a reference fiber. Top quality sensor technology ensures rapid and precise fault determination. Use of OTDRs (Optical Time Domain Reflec tometers) makes precision location of faults feasible. Sensors and OTDRs attuned to the extant transmission wavelengths are used as the tasks involved require. Service transmission via the fibers isn't influenced by monitoring. The LANCIER fiber optic monitoring system allows you to monitor active and dark fibers, optical power, optical attenuation (loss), with reflectometers (OTDRs), and humidity penetration. with fault location Optical Switch OTDR (Optical Time Domain Reflectometer) 4

5 Optical Attenuation Loop Measurement FiberTxA Fiber optic trunk cable Serial Measurement FiberTxA Fiber optic trunk cable Tx-Bus or CAN-Bus Optical Power OptTxA Backscattering trace of an optical fiber Optical receiver Fiber optic trunk cable Optical emitter External Services SMS Fax Pager... Report TMN (Telecommunication Management Network) Cable Management System GIS (Geographical Information System) Server 5

6 Copper Cable Network Insulation and Loop Resistance In copper cable networks insulation and loop resistance of a representative measurement pair can be monitored. If humidity gets in resistance changes. The monitoring system detects this and advises of it. There are a variety of system options depending on the structure of the network to be monitored and the extant communication infrastructure. several cables The stand-alone MUX 101-IMS monitoring station can monitor up to ten cables. Signal and alarm output is via relay contacts. Adaptable interfaces permit integration of the MUX 101-IMS in the Unified System and remote control. of single cables The insulation sensor IsoTxA-Mk2 is a stand-alone monitoring device for single cables. Alarm output is via relay contacts. Adaptable interfaces permit integration of the IsoTxA-Mk2 in the Unified System via a and remote control. Long cables can be economically monitored using several IsoTxA-Mk2 devices. Insulation and Loop Resistance several cables of single cables MUX 101-IMS max. 10 measurement loops IsoTxA-Mk2 SMS Fax Pager... Report 6 Server

7 Pressurisation and Humidity inside Sleeves Pressurisation Cable protected by pressurised air can be seamlessly monitored from the pressurisation system on. Immediately thereafter addressable flow sensors permanently monitor air consumption. Pressure sensors measure local cable pressure in cable sleeves and externally in distribution cabinets or manholes. On the basis of the measurement data cable faults and their location can be determined before they cause trouble. The collects the addressable sensor measurement data and evaluates measured values on the basis of individually programmable thresholds. The Unified System in association with geographic network data precisely locates faults. Pressurisation and Humidity Humidity inside Sleeves In jelly-filled cables sleeves are the weakest points. Humidity penetration causes corrosion of connections and insulation resistance worsens. Addressable humidity sensors measure relative humidity in sleeves and make fault locations precisely identifiable. Pressurisation Pressurisa - tion System FMA 200 C Trunk cable with measurement pair PTxA 210 Distribution Cabinet Sleeve PTxA 210 Humidity Trunk cable with measurement pair Sleeve HTxA 5/95 External Services TMN (Telecommunication Management Network) Cable Management System GIS (Geographical Information System) 7

8 of plants and systems Machinery and equipment can also be monitored as well as cable networks. Access can be controlled using sensors with contacts and optical sensors used to monitor even directional short-circuit indicators in medium-voltage power grids. All sensor thresholds are freely programmable. The collects sensing point conditions and evaluates them using the individually programmable thresholds. The Unified System together with geographical network and inventory data shows - the sensing point condition graphically, - the position of sensing points in the network, and - their geographical positions. Plants and Systems Physical Parameters: Pressure, Humidity, Temperature... Contactors Access Control... SMS External Services Fax Report TMN (Telecommunication Management Network) Pager... LANCIER GmbH Gustav-Stresemann-Weg Münster, Germany Tel. +49 (0) Fax +49 (0) Server Cable Management System GIS (Geographical Information System) Ko/02.09 Alterations reserved. Printed in Germany

Cable Network Transparency Fiber Optic Monitoring

Cable Network Transparency Fiber Optic Monitoring Cable Network Transparency Fiber Optic Monitoring Fault recognition, localisation and reporting Fiber Optic Cable Future of Telecommunication The demand for complex fiber optic cable networks and flexible

More information

Optical Network Management System. Remote Testing, Network Monitoring, and Service Provisioning Solution for High-Quality Network Performance

Optical Network Management System. Remote Testing, Network Monitoring, and Service Provisioning Solution for High-Quality Network Performance Optical Network Management System Remote Testing, Network Monitoring, and Service Provisioning Solution for High-Quality Network Performance JDSU Enabling Broadband and Optical Innovation Improving the

More information

Wide-Area Optical Fiber Network Monitoring and Management System

Wide-Area Optical Fiber Network Monitoring and Management System by Kunihiro Yamamoto *, Masahide Ogawa *, Tetsuhiro Yamashita * and Masao Sasaki * The optical fiber cable networks that form the backbone of high-speed ABSTRACT communications are increasingly being laid

More information

OFM-500 Optical Fiber Mapping Software. A complete software application for managing documentation in fiber optic plants

OFM-500 Optical Fiber Mapping Software. A complete software application for managing documentation in fiber optic plants OFM-500 Optical Fiber Mapping Software A complete software application for managing documentation in fiber optic plants OFM-500 Optical Fiber Mapping (OFM) Software Designed by fiber optic engineers for

More information

Optical Submarine Cable Network Monitoring Equipment

Optical Submarine Cable Network Monitoring Equipment Optical Submarine Cable Network Monitoring Equipment NOMURA Kenichi, TAKEDA Takaaki Abstract The introduction of large-capacity wavelength-division multiplexing and OADM (Optical Add/Drop Multiplexing)

More information

Modularized and Multi-Functional Power Distribution for Cabinets 3.01

Modularized and Multi-Functional Power Distribution for Cabinets 3.01 Modularized and Multi-Functional Power Distribution for Cabinets 3.01 1 1 Intelligent Data Center Solutions for Networks of the Future Hexatronic offers reliable, high quality data center solutions designed

More information

TECHNICAL DESCRIPTION OF THE DISTRIBUTION SUBSTATION REMOTE MONITORING SYSTEM

TECHNICAL DESCRIPTION OF THE DISTRIBUTION SUBSTATION REMOTE MONITORING SYSTEM HELLENIC ELECTRICITY DISTRIBUTION NETWORK OPERATOR S.A. NOTICE OF CALL FOR TENDERS No ND-xxx PROJECT: Pilot Telemetering and Management System for the Electric Power Supply Demand by Residential and Small

More information

IPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network

IPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network IPThermo206G Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network IPThermo 206G is the central data handling terminal of the IPThermo Pro measurement network. This

More information

Line Monitoring and Control in Subsea Networks

Line Monitoring and Control in Subsea Networks Line Monitoring and Control in Subsea Networks This paper discusses how submerged equipment is monitored and contrasts different methods of doing this. It also considers what features are required by the

More information

Domain 5.0: Network Tools

Domain 5.0: Network Tools ExamForce.com CompTIA Network+ N10-004 Study Guide 1 Domain 5.0: Network Tools Chapter 5 5.1 Given a scenario, select the appropriate command line interface tool and interpret the output to verify functionality

More information

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

Loop-O9310 4E1 or 4T1 Fiber Optical Mux Loop- E or T Fiber Optical Mux Description Features CPU Version Non-CPU Version Up to E or T links on one fiber Optical + protection 0/00 BaseT Ethernet Bridge mode, maximum transmission bandwidth 22Mbps

More information

Utility Communications FOXMAN-UN Network Management System for ABB Communication Equipment

Utility Communications FOXMAN-UN Network Management System for ABB Communication Equipment Utility Communications FOXMAN-UN Network Management System for ABB Communication Equipment A reliable & flexible communication network lies at the heart of successful electrical grid operations. A comprehensive

More information

LNG Monitoring. Fiber-Optic Leakage Detection System. Pipeline leakage detection. Regasification and liquefaction monitoring

LNG Monitoring. Fiber-Optic Leakage Detection System. Pipeline leakage detection. Regasification and liquefaction monitoring LNG Monitoring Fiber-Optic Leakage Detection System Pipeline leakage detection Regasification and liquefaction monitoring Tank annulus and base slab monitoring Spill containment control Intelligent Solutions

More information

Telecommunications Training Catalog

Telecommunications Training Catalog Open Enrollment & Contract Courses Online Training Customized Training Technical Assistance Telecommunications Training Catalog Boost Your Knowledge BitRate with Us! The Telecommunications Training Program

More information

Permissible ambient temperature Operation Storage, transport

Permissible ambient temperature Operation Storage, transport The Sitras PRO combined DC protective unit and controller is used in the power supply for DC railways in mass transit and main-line systems up 3,000 V DC. It protects DC switch gear and contact line systems

More information

Data Logger & Net Client Software (Windows, ipad, Android) Instant On. Touch. Drop & Drag Opera on. No more proprietary display equipment!

Data Logger & Net Client Software (Windows, ipad, Android) Instant On. Touch. Drop & Drag Opera on. No more proprietary display equipment! Data Logger & Net Client Software (Windows, ipad, Android) builds an Intelligent HMI system Instant On. Touch. Drop & Drag Opera on. No more proprietary display equipment! Running a HMI system with your

More information

Comprehensive geospatial network management based on MapInfo. Supporting both physical and logical network resource management

Comprehensive geospatial network management based on MapInfo. Supporting both physical and logical network resource management Comprehensive geospatial network management based on MapInfo Supporting both physical and logical network resource management ConnectMaster is an open, integratable, scalable software solution for the

More information

The best network information. COPA-DATA know-how: SNMP with zenon

The best network information. COPA-DATA know-how: SNMP with zenon The best network information COPA-DATA know-how: SNMP with zenon The best network information COPA-DATA know-how: SNMP with zenon A control system for Energy Automation always has many different IT devices.

More information

Process Instrumentation

Process Instrumentation Process Instrumentation Analysis by Gas Chromatography Engineered Solutions, Guaranteed Results. WASSON - ECE INSTRUMENTATION Process Gas Chromatography Features of Process Chromatographs Agilent 7890A

More information

Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation

Intelligent chart recorder for compressed air and gases. Measurement - control - indication - alarm - recording - evaluation DS 500 Intelligent chart recorder for compressed air and gases Measurement - control - indication - alarm - recording - evaluation new Advantages at a glance: Clear layout: 7" colour screen with touch

More information

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

Loop-O9310 4E1 or 4T1 Fiber Optical Mux Loop-O930 E or T Fiber Optical Mux Features Up to E or T links on one fiber Optical + protection 0/00 BaseT Ethernet Bridge mode, maximum transmission bandwidth 22Mbps (optional) One V.35, X.2, RS9/V.36,

More information

TereScope Management Options

TereScope Management Options Introduction TereScope Management Options MRV Communications, Inc. offers a variety of management options for the TereScope FSO product family. Whether you are a Network Service Provider, Cellular Network

More information

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX-2017-12NDS Intelligent Network Fire Alarm Control Unit. Features. Description

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX-2017-12NDS Intelligent Network Fire Alarm Control Unit. Features. Description INTELLIGENT FIRE ALARM CONTROL UNITS MMX-2017-12NDS Intelligent Network Fire Alarm Control Unit Description Secutron s MMX-2017-12NDS Network Fire Alarm Control Unit offers modular components to meet a

More information

Cabling & Test Considerations for 10 Gigabit Ethernet LAN

Cabling & Test Considerations for 10 Gigabit Ethernet LAN Introduction Current communication data rates in local networks range from 10/100 megabits per second (Mbps) in Ethernet to 1 gigabit per second (Gbps) in fiber distributed data interface (FDDI) and Gigabit

More information

Fiber Optic Distributed Temperature Sensor (B-DTS)

Fiber Optic Distributed Temperature Sensor (B-DTS) Fiber Optic Distributed Temperature Sensor (B-DTS) Low-cost Brillouin BOTDA scattering version For more information about our strain and temperature sensor system and related products, please visit www.ozoptics.com

More information

3.1 TELECOMMUNICATIONS, NETWORKS AND THE INTERNET

3.1 TELECOMMUNICATIONS, NETWORKS AND THE INTERNET 3.1 TELECOMMUNICATIONS, NETWORKS AND THE INTERNET The Business Value of Telecommunications and Networking Business value impacts of the telecommunications and Networking are: Declining transaction costs

More information

2-Pair HDSL1 Adtran Fiber Optic Link System

2-Pair HDSL1 Adtran Fiber Optic Link System ISSUE 2 June 01, 2004 Data Sheet #37 2-Pair HDSL1 Adtran Fiber Optic Link System Contents 1. General. 1 2. Application... 2 3. Housings.. 2 4. Installation 3 5. Provisioning. 5 6. LED Indicators. 6 7.

More information

ITEM M -- INSTALL FIELD FRACTIONAL T-1 MULTIPLEXER ITEM M -- FURNISH AND INSTALL TOC FRACTIONAL T-1 MULTIPLEXER

ITEM M -- INSTALL FIELD FRACTIONAL T-1 MULTIPLEXER ITEM M -- FURNISH AND INSTALL TOC FRACTIONAL T-1 MULTIPLEXER DESCRIPTION This work shall consist of installing Field T-1 communications equipment consisting of Fractional T-1 Multiplexer/Demultiplexers (Fractional ADM Multiplexers) equipped with electrical interface

More information

Introduction To SCADA and Telemetry

Introduction To SCADA and Telemetry Introduction To SCADA and Telemetry Joe Mullaney Senior I&C Engineer MSE Technology Applications, Inc. Tetragenics Division joe.mullaney@mse-ta.com Overview Definitions What is SCADA? What is Telemetry?

More information

GSM Voice Auto Dialer & SMS Sender JC-999

GSM Voice Auto Dialer & SMS Sender JC-999 GSM Voice Auto Dialer & SMS Sender JC-999 Main features: () Large LCD display,integrated integrated keypad, human-friendly programming; (2) Support 2 alarm receiving numbers; (3) Triggering means: N.C

More information

Network Monitoring and Diagnostics Connected Manufacturing usa.siemens.com/industry Page 1 What is Network Monitoring and Diagnostics? Network Monitoring A system that is constantly monitoring networks

More information

Network and Facility Management: Needs, Challenges and Solutions

Network and Facility Management: Needs, Challenges and Solutions Network and Facility Management: Needs, Challenges and Solutions Graham Jones Harris Broadcast Communications gjones04@harris.com New tools are needed to enable broadcasters to efficiently manage the modern

More information

NEW GENERATION PROGRAMMABLE AUTOMATION CONTROLLER

NEW GENERATION PROGRAMMABLE AUTOMATION CONTROLLER NEW GENERATION PROGRAMMABLE AUTOMATION CONTROLLER NEW GENERATION PROGRAMMABLE AUTOMATION CONTROLLER Understanding what a PAC is starts from the understanding of PLC. A PLC is a Programmable Logic while

More information

Technologies for Data Centres

Technologies for Data Centres Technologies for Data Centres BlueNet at a glance // PHILOSOPHY A passion for innovation page 5 // ENERGY MANAGEMENT The latest in efficiency page 7 // HIGH AVAILABILITY Seamless and systematic security

More information

ISIO 200. Binary Input/Output (I/O) Terminal with IEC 61850 Interface

ISIO 200. Binary Input/Output (I/O) Terminal with IEC 61850 Interface ISIO 200 Binary Input/Output (I/O) Terminal with IEC 61850 Interface Compact and Easy ISIO 200 Put your Binary I/Os where you need them ISIO 200 is a simple and versatile binary I/O terminal with IEC 61850

More information

Options and monitoring

Options and monitoring Additional outlets Energy distribution unit with two Schuko-outlets and four IEC-outlets. Rackmount module version with a height of 2 units. Parallel Distribution Box with Bypasss A compact distribution

More information

Automatic Transfer Switch-Controller ATS-C by Eaton. Automatic Transfer Switch- Controller ATS-C 96 and C 144

Automatic Transfer Switch-Controller ATS-C by Eaton. Automatic Transfer Switch- Controller ATS-C 96 and C 144 Automatic Transfer Switch-Controller ATS-C by Eaton Automatic Transfer Switch- Controller ATS-C 96 and C 144 Supply safety for low voltage energy distribution. Automatic Transfer Switch-Controller ATS-C

More information

Premium Server Client Software

Premium Server Client Software Premium Server Client Software Server / Client SMSPro & GSMS TH series Get the tools on hand Premium Server is designed to cover most of the applications in the market. It gives a hassle free management

More information

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

Loop-O9310 4E1 or 4T1 Fiber Optical Mux Loop-O930 E or T Fiber Optical Mux Features CPU Version Up to E or T links on one fiber Optical + protection 0/00 BaseT Ethernet Bridge mode, maximum transmission bandwidth 22Mbps (optional) One V.35,

More information

Broadband 101: Installation and Testing

Broadband 101: Installation and Testing Broadband 101: Installation and Testing Fanny Mlinarsky Introduction Today the Internet is an information superhighway with bottlenecks at every exit. These congested exits call for the deployment of broadband

More information

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS Vehicle or Personal Position Tracking Vehicle Status and Speed Tracking Auto Accident Report Global Position System (GPS) Navigation System Anti theft Alarm System Overview 1. GPS data tracking via GSM

More information

Swiss Time Systems. The new multipurpose time server for the LAN and NTP-based Distributed Time System. by MOBATIME DTS 4138.

Swiss Time Systems. The new multipurpose time server for the LAN and NTP-based Distributed Time System. by MOBATIME DTS 4138. Proud Partners with MOBATime GPS or DCF 77 MOBA-NMS (Network Management Sy The new multipurpose time server for the LAN and NTP-based Distributed Time System by MOBATIME DTS 4138.timeserver The DTS 4138.timeserver

More information

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev.

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev. TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev. 0 1. Generality 3 2. Introduction 3 3. Accessories and Options 3 4. Installation 3 5. Connection

More information

Linear Heat Series. Fiber Optic Linear Heat Detection System. Tunnels & Metros. Conveyer Belts. Parking Lots. Manufacturing Warehouse Facilities

Linear Heat Series. Fiber Optic Linear Heat Detection System. Tunnels & Metros. Conveyer Belts. Parking Lots. Manufacturing Warehouse Facilities Linear Heat Series Fiber Optic Linear Heat Detection System Tunnels & Metros Conveyer Belts Parking Lots Manufacturing Warehouse Facilities Refineries and Power Plants Intelligent Solutions Are you looking

More information

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter ICS-2 S15 Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter Cost Effective Solution for RS-232 / RS-422 / RS-485 to Industrial Ethernet Application PLANET ICS-210x series Smart Media Converter

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically

More information

for CS flow / dew point sensors

for CS flow / dew point sensors Operating Manual Service Software for CS flow / dew point sensors FA300/ VA300/ DP300/ FA4XX / VA4XX - 1 - V-3-03-2008 Service Software for flow / dew point sensors Introduction This service software can

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,

More information

Hosted Testing and Grading

Hosted Testing and Grading Hosted Testing and Grading Technical White Paper July 2014 www.lexmark.com Lexmark and Lexmark with diamond design are trademarks of Lexmark International, Inc., registered in the United States and/or

More information

25 Years of Manufacturing Excellence. Premier Quatro Addressable Fire Alarm System. Assessed to ISO 9001: 2008

25 Years of Manufacturing Excellence. Premier Quatro Addressable Fire Alarm System. Assessed to ISO 9001: 2008 Premier Quatro Addressable Fire Alarm System Premier Quatro 4 Loop Analogue Addressable Fire Alarm Panel The Premier Quatro is the new 4 loop analogue Alarm Systems. It is available in 1, 2, 3 or 4 loop

More information

STAR PIPE Polska S.A ul. Gdyńska 51 62-004 Czerwonak tel. +48 61 667 41 20 fax +48 61 667 41 38

STAR PIPE Polska S.A ul. Gdyńska 51 62-004 Czerwonak tel. +48 61 667 41 20 fax +48 61 667 41 38 THE ALARM SYSTEM The base of the system consists of two non-insulated copper alarm wires with section equal to 1.5 mm2, located inside polyurethane foam parallel to the conduit pipe, offset in relation

More information

Cable Management. Stay in control full insight into inside & outside plant management ensures. that you stay on top of cable management.

Cable Management. Stay in control full insight into inside & outside plant management ensures. that you stay on top of cable management. Cable Management Stay in control full insight into inside & outside plant management ensures that you stay on top of cable management. www.fntsoftware.com Global mobile data traffic will increase nearly

More information

TrueAlarm Fire Alarm Systems

TrueAlarm Fire Alarm Systems TrueAlarm Systems UL, ULC, CSFM Listed; FM Approved* Network Annunciators; es Features Provides a dedicated local area network (LAN) for connection of a TrueSite workstation server to remote clients: es

More information

SCADA and Monitoring for Solar Energy Plant

SCADA and Monitoring for Solar Energy Plant SCADA and Monitoring for Solar Energy Plant Segment: Industry Country: Thailand Author: Ranon Satitpanyapan Products: NI LabVIEW with LabVIEW Real-Time Module crio Real-Time controller 8 slot with 16 current

More information

Power network telecommunication

Power network telecommunication www.siemens.com Power network telecommunication Teleprotection Answers for infrastructure and cities. Binary I/O The best protection against high-voltage grid failures When it comes to managing power networks,

More information

Reducing operating costs of telecom base stations with remote management

Reducing operating costs of telecom base stations with remote management Reducing operating costs of telecom base stations with remote management Whitepaper How remote management can be used to cut operating expenses of existing telecom infrastructure. HMS Industrial Networks

More information

Product Guide CM-Relay

Product Guide CM-Relay Product Guide CM-Relay www.theclimate.co.uk tel: 01491 410913 The Climate, Badgers Bank, Harpsden, Henley-on-Thames, Oxfordshire RG9 4HL. Overview CM-Relay combines climate monitoring with remote relay

More information

S a f e G u i d a n c e. Single Lamp Control and Monitoring

S a f e G u i d a n c e. Single Lamp Control and Monitoring Single Lamp Control and Monitoring S a f e G u i d a n c e Separation brings Benefits Traditionally designed power supplies for airfield lighting systems require separate series circuits when switching.

More information

Acterna DSL Services Tester TPI 350+ Application Highlights

Acterna DSL Services Tester TPI 350+ Application Highlights Acterna TPI 350+ DSL Test Set Product Highlights Field engineered, rugged construction, lightweight design, and batterypowered operation Automated testing capabilities minimize training costs and testing

More information

Resolution of comments 242 and 267 on Insertion loss measurements of installed fiber cables. Steve Swanson May 5, 2009

Resolution of comments 242 and 267 on Insertion loss measurements of installed fiber cables. Steve Swanson May 5, 2009 Resolution of comments 242 and 267 on Insertion loss measurements of installed fiber cables Steve Swanson May 5, 2009 Current text in 86.10.1 Insertion loss measurements of installed fiber cables are made

More information

Troubleshooting and Auto-Negotiation Features for IMC Networks Media Conversion Products

Troubleshooting and Auto-Negotiation Features for IMC Networks Media Conversion Products Troubleshooting and Auto-Negotiation Features for IMC Networks Media Conversion Products Table of Contents Introduction...................................................................... 1 About Link

More information

Software Solutions for the Telecommunications Industry

Software Solutions for the Telecommunications Industry Software Solutions for the Telecommunications Industry A Unique Framework NCT software platform the building block Framework Architecture Framework Architecture NCT - Fault Management Fault Registration

More information

LB Sky Global. 92 Lobachevskogo St, Bld 92, Office 5, Moscow, Russia 119454 Tel/Fax 7(495)229-39-78, E-mail: office@grouplb.com, Site: www.grouplb.

LB Sky Global. 92 Lobachevskogo St, Bld 92, Office 5, Moscow, Russia 119454 Tel/Fax 7(495)229-39-78, E-mail: office@grouplb.com, Site: www.grouplb. Perimeter security system T-REX Moscow, 2011 Table of content 1. Introduction... 3 2. Main features of the T-REX system... 3 3. Structure of the system... 5 4. SL-6000 system sensors... 6 5. Signal processing

More information

MOUNTING AND OPERATING INSTRUCTIONS

MOUNTING AND OPERATING INSTRUCTIONS MOUNTING AND OPERATING INSTRUCTIONS CF 51/55 1. Delivery CF 51/55-1 calculator with battery (optionally with mains power supply) - 1 wall mounting bracket - package with material for sealing, screws, wall

More information

Distributed Temperature Monitoring of Energy Transmission and Distribution Systems

Distributed Temperature Monitoring of Energy Transmission and Distribution Systems 1 m 40000m0 range 61850 IEC spatial resolution Distributed Temperature Monitoring of Energy Transmission and Distribution Systems Ensuring a Reliable Supply of Electrical Power for Today s World www.en-sure.pro

More information

Integrated management information in utilities

Integrated management information in utilities Integrated management information in utilities Information from Cigré The objective of this article is to assist utilities define, specify and evaluate the high level management systems that form the information

More information

EXPERTS IN WATER COOLING SINCE 2001. aquastream ULTIMATE SUPER SILENT PUMP TECHNOLOGY. The ultimate pump system. www.aqua-computer.

EXPERTS IN WATER COOLING SINCE 2001. aquastream ULTIMATE SUPER SILENT PUMP TECHNOLOGY. The ultimate pump system. www.aqua-computer. The ultimate pump system www.aqua-computer.de AQUASTREAM Since its market introduction in 2003, the name stands for reliable and durable water cooling pump technology - made in Germany. We have bundled

More information

STATE OF NEVADA Department of Administration Division of Human Resource Management CLASS SPECIFICATION

STATE OF NEVADA Department of Administration Division of Human Resource Management CLASS SPECIFICATION STATE OF NEVADA Department of Administration Division of Human Resource Management CLASS SPECIFICATION TITLE GRADE EEO-4 CODE DIGITAL TELECOMMUNICATIONS SUPERVISOR 37 B 6.963 SERIES CONCEPT Digital Telecommunications

More information

Management of Converging Networks

Management of Converging Networks Greater Chicago Chapter Thursday, 9-21-00 of Converging Networks Paul T. Schauer, PE Lucent Technologies Agenda Converging Networks Why Network? What Is Network? Network for CATV 2 Converging Networks

More information

SYSTEMS CALL CENTER GLOBAL RETAIL SOLUTION XWEB5000 XCENTER XWEB3000 XWEB500 - XWEB500D XWEB300D

SYSTEMS CALL CENTER GLOBAL RETAIL SOLUTION XWEB5000 XCENTER XWEB3000 XWEB500 - XWEB500D XWEB300D GLOBAL RETAIL SOLUTION Research, great experience, regulation and design innovation: these are the elements that allow Dixell to offer controllers and supervising systems that are in the forefront for

More information

FT-1000/GPS-N. System of remote monitoring and control of physical

FT-1000/GPS-N. System of remote monitoring and control of physical FT-1000/GPS-N System of remote monitoring and control of physical Localization of vehicles during transport by sending the values of temperature, RH%, etc.. with relative alarm threshold is exceeded. Send

More information

Secure your electrical network. PACiS The Safety Solution for Healthcare Institutions

Secure your electrical network. PACiS The Safety Solution for Healthcare Institutions Secure your electrical network The Safety Solution for Healthcare Institutions Fast Secure : the solution for fault isolation and electrical network restoration in less than 500 ms 03 A Real Time System

More information

WaveReady CFM. Optical Link Monitoring System: Continuous Fiber Monitor

WaveReady CFM. Optical Link Monitoring System: Continuous Fiber Monitor WaveReady CFM Optical Link Monitoring System: Continuous Fiber Monitor www.lumentum.com Data Sheet The Lumentum Continuous Fiber Monitor (CFM) offers a compact, modular solution for performance monitoring

More information

Advanced Fencing and Security Technologies Ltd

Advanced Fencing and Security Technologies Ltd G.M. Advanced Fencing and Security Technologies Ltd P.O. Box 2327 Kfar Sava Industrial Area 44425, Israel Tel +972-9-7662965 Fax + 972-9-7662964 E-mail: info@gmsecurity.com Website: www.gmsecurity.com

More information

OPT-700 - SERIAL TO FIBER OPTIC CONVERTER

OPT-700 - SERIAL TO FIBER OPTIC CONVERTER USER S MANUAL OPT-700 - SERIAL TO FIBER OPTIC CONVERTER JUL / 05 OPT-700 VERSION 1 TM FOUNDATION OPT700ME smar www.smar.com Specifications and information are subject to change without notice. Up-to-date

More information

FIBER OPTIC CABLE PLANT DOCUMENTATION

FIBER OPTIC CABLE PLANT DOCUMENTATION C H A P T E R 13 FIBER OPTIC CABLE PLANT DOCUMENTATION JIM HAYES Documenting the fiber optic cable plant is a necessary part of the design and installation process for the fiber optic network. Documenting

More information

TRAM LINE SWITCH POINT HEATING

TRAM LINE SWITCH POINT HEATING ENERGY SAVING SMART CITY WEATHER CONTROL TRAM LINE SWITCH POINT HEATING 50 80% Energy saving Heating controlled by weather conditions and weather forecast Long life heating elements Monel corrosion resistant

More information

ONMSi: Optical Network Monitoring System

ONMSi: Optical Network Monitoring System ONMSi: Optical Network Monitoring System Fiber network visibility that scales for both PON and point-to-point networks Drastically reduce network downtime Improve network reliability and SLA management

More information

Optical Fiber Data Center Field Testing. ANSI/BICSI 002-2011 Data Center Design and Implementation Best Practices

Optical Fiber Data Center Field Testing. ANSI/BICSI 002-2011 Data Center Design and Implementation Best Practices Optical Fiber Data Center Field Testing ANSI/BICSI 002-2011 Data Center Design and Implementation Best Practices Abstract Data Centers are a growing segment of the enterprise market. Regardless of whether

More information

Current Monitoring Kit QUICK START GUIDE

Current Monitoring Kit QUICK START GUIDE Current Monitoring Kit QUICK START GUIDE Pico Technology EL040 Current Monitoring Kit Quick Start Guide CONTENTS 1 Introduction... 1 2 Kit contents... 3 3 Installation... 3 3.1 Connecting the system together...

More information

CHAPTER 18 THE PUBLIC TELEPHONE NETWORK # DEFINITIONS TERMS

CHAPTER 18 THE PUBLIC TELEPHONE NETWORK # DEFINITIONS TERMS CHAPTER 18 THE PUBLIC TELEPHONE NETWORK # DEFINITIONS TERMS 1) It uses the largest computer network in the world to interconnect millions of subscribers in such a way that the myriad of companies function

More information

Telcordia Network Engineer Andrius Petrauskas Project Manager

Telcordia Network Engineer Andrius Petrauskas Project Manager Telcordia Network Engineer Andrius Petrauskas Project Manager A geospatial network management system designed for the communications industry Is the most comprehensive geospatial solution for the design

More information

Utilizing Furukawa Optical Fiber Technology. Optical Fiber Sensing System

Utilizing Furukawa Optical Fiber Technology. Optical Fiber Sensing System Utilizing Furukawa Optical Fiber Technology Optical Fiber Sensing Point Special features of optical fiber sensing s 1Reduced installation cost Sensors (measurement location) require no electrical work

More information

sat-nms SMU Signal Management Unit

sat-nms SMU Signal Management Unit sat-nms SMU Signal Management Unit Application Note 2014, SatService GmbH www.satnms.com SMU-APP-1408-1 1/37 1 System Description and Configuration of sat-nms SMU The sat-nms SMU is the unit you were always

More information

Technical Information POWER PLANT CONTROLLER

Technical Information POWER PLANT CONTROLLER Technical Information POWER PLANT CONTROLLER Content The Power Plant Controller offers intelligent and flexible solutions for the control of all PV power plants in the megawatt range. It is suitable for

More information

CUSTOMER REQUIREMENTS AT POWER SUBSTATIONS

CUSTOMER REQUIREMENTS AT POWER SUBSTATIONS CUSTOMER REQUIREMENTS AT POWER SUBSTATIONS Customer Handout Date Aug 2, 2010 Version 1.0 File Name Customer Requirements At Power Substations Document Id Outside Plant Engineering 1 Table Of Contents 1.0

More information

ONMSi: Optical Network Monitoring System

ONMSi: Optical Network Monitoring System ONMSi: Optical Network Monitoring System Fiber network visibility that scales for both PON and point-to-point networks Drastically reduce network downtime Improve network reliability and SLA management

More information

Current Monitoring Kit

Current Monitoring Kit Current Monitoring Kit QUICK START GUIDE DO090-6 CONTENTS Issues: 1) 2.10.02 WP A4 format 2) 2.10.02 Added safety warning 3) 17.3.06 Word A5 format. S1: Removed relay modules. S2: Added MI010. S4.1: added

More information

IO-Link System Description Technology and Application

IO-Link System Description Technology and Application www.io-link.com Technology and Application Contents PREFACE... 3 1 BENEFITS OF IO-LINK... 4 2 SYSTEM OVERVIEW... 5 2.1 OVERVIEW OF IO-LINK... 5 2.2 IO-LINK INTERFACE... 6 2.3 IO-LINK PROTOCOL... 7 2.4

More information

RiZone Data Centre Infrastructure Management

RiZone Data Centre Infrastructure Management RiZone Data Centre Infrastructure Management Enclosures Power Distribution Climate Control IT INFRASTRUcTURe SOFTWARE & SERVICEs RiZone Data Centre Infrastructure Management What can the RiZone Data Centre

More information

The Business case for monitoring points... PCM architecture...

The Business case for monitoring points... PCM architecture... The Business case for monitoring points... Points Condition Monitoring (PCM) measures key parameters related to the performance of switch machines and turnouts in real time at every movement. Intelligent

More information

Networks. The two main network types are: Peer networks

Networks. The two main network types are: Peer networks Networks Networking is all about sharing information and resources. Computers connected to a network can avail of many facilities not available to standalone computers: Share a printer or a plotter among

More information

VIBROCONTROL 4000. Sensitive Machine Monitoring

VIBROCONTROL 4000. Sensitive Machine Monitoring VIBROCONTROL 4000 Sensitive Machine Monitoring Reliable Machine Protection with VIBROCONTROL 4000 Brüel & Kjaer Vibro has for many years been one of the leading manufacturers of machine protection systems.

More information

- Remote management of industrial applications. Save time, save energy, save resources!

- Remote management of industrial applications. Save time, save energy, save resources! - Remote management of industrial applications Save time, save energy, save resources! Your challenges Minimize scheduled and emergency on-site service Optimize service operations through efficient machine/device

More information

T1 Backhaul Connectivity Solution All Products :: Application Note

T1 Backhaul Connectivity Solution All Products :: Application Note Telect 1 RU Customer Interface Panel (CIP) Enables Demarcation, Remote Circuit Maintenance and Trouble Isolation at the Backhaul Node The Application: T1 Demarcation and Testing in Backhaul Environments

More information

Media Conversion in Video Security and Surveillance Systems

Media Conversion in Video Security and Surveillance Systems The Conversion Technology Experts Media Conversion in Video Security and Surveillance Systems Worldwide Headquarters 6475 City West Parkway Eden Prairie, MN 55344 USA tel 952.941.7600 toll free 800.526.9267

More information

Earth Fault Detection Basics in Theory

Earth Fault Detection Basics in Theory Earth Fault Detection Basics in Theory Author: Dipl.-Ing. Ingo Kühnen Woodward Power Solutions Krefelder Weg 47 47906 Kempen, Germany Kempen, 16.04.2010 Earth_Fault_Detection_20100416.doc page 1 1. Star

More information

DALI RC BASIC SO. Control unit Operating instructions

DALI RC BASIC SO. Control unit Operating instructions DALI RC BASIC SO Control unit Operating instructions Contents Safety... 4 General instructions 4 Safety instructions 4 Description... 5 Purpose and application 5 Function 5 Light control 5 Brightness

More information

DCM. Product Brochure. Diagnostic Communication Master

DCM. Product Brochure. Diagnostic Communication Master DCM Product Brochure Diagnostic Communication Master DCM The DCM Diagnostic Communication Master is the best solution for the control of actuators from a remote control room through a two-wire transmission-mode

More information

FAST TUTORIALS FOR TIME-CHALLENGED TECHNICIANS

FAST TUTORIALS FOR TIME-CHALLENGED TECHNICIANS Tech Notes from a Telephone Engineer FAST TUTORIALS FOR TIME-CHALLENGED TECHNICIANS POTS Dialtone Description: POTS Plain Old Telephone Service Long held industry acronym for standard dialtone service

More information