Second Revision No. 9-NFPA [ Global Comment ] Submitter Information Verification. Committee Statement 5/30/2014 8:36 AM

Size: px
Start display at page:

Download "Second Revision No. 9-NFPA 120-2014 [ Global Comment ] Submitter Information Verification. Committee Statement 5/30/2014 8:36 AM"

From this document you will learn the answers to the following questions:

  • What was the number of the change in the name of the new system?

  • What part of the equipment is considered to be safe for use?

  • What is the main component of a engineered system?

Transcription

1 of 37 5/30/2014 8:36 AM Second Revision No. 9-NFPA [ Global Comment ] Change title of to Self-Propelled Equipment Submitter Information Verification Submitter Full Name: [ Not Specified ] Organization: [ Not Specified ] Street Address: City: State: Zip: Submittal Date: Tue Jan 07 16:58:40 EST 2014 Committee Statement Committee Statement: Response Message: Product of task group work on self-propelled and mobile equipment to clarify and distinguish between the types of equipment.

2 of 37 5/30/2014 8:36 AM Second Revision No. 2-NFPA [ Section No ] Fixed Fire Suppression System. A An engineered or pre-engineered total flooding or local application system consisting of a fixed supply of extinguishing agent permanently connected for fixed agent distribution to fixed nozzles that are arranged to discharge an extinguishing agent into an enclosure (total flooding), directly onto a hazard (local application), or a combination of both; or an automatic sprinkler system. [122, 2015] Engineered Systems. Engineered systems are those systems requiring individual calculation and design to determine the flow rates, nozzle pressures, pipe size, area, or volume protected by each nozzle, quantity of suppression agent, number and types of nozzles and their placement in a specific system Pre-Engineered Systems. Those systems having predetermined flow rates, nozzle pressures, and quantities of extinguishing agent and having specific pipe size, maximum and minimum pipe lengths, flexible- - hose specifications, number or of fittings, and number and types of nozzles. [17, 2013] Submitter Information Verification Submitter Full Name: [ Not Specified ] Organization: [ Not Specified ] Street Address: City: State: Zip: Submittal Date: Tue Jan 07 11:06:25 EST 2014 Committee Statement Committee Statement: Response Message: The technical committee added the definitions of engineered and pre-engineered systems to the definition of fixed fire suppression systems. This will also address public comments no. 3 and 4 and committee comments on FR-67. The committee feels that both definitions should be part of Chapter 3. Pre-engineered Systems is being moved from existing

3 of 37 5/30/2014 8:36 AM Second Revision No. 8-NFPA [ Section No ] * Mobile Equipment. Wheeled, skid-mounted, track-mounted, or rail-mounted equipment capable of moving or being moved. [ 122, 2015] Submitter Information Verification Submitter Full Name: [ Not Specified ] Organization: [ Not Specified ] Street Address: City: State: Zip: Submittal Date: Tue Jan 07 16:49:26 EST 2014 Committee Statement Committee Statement: Response Message: Product of task group - mobile equipment definition is now consistent between the 120 and 122

4 of 37 5/30/2014 8:36 AM Second Revision No. 14-NFPA [ Section No ] Safety Can. A listed container, of not more than L (5 5.3 gal) capacity, having a screen or strainer in each fill and pour opening and having a spring-closing lid and spout cover and so designed that it will to safely relieve internal pressure when subjected exposed to fire exposure. [ 30, 2015] Submitter Information Verification Submitter Full Name: [ Not Specified ] Organization: [ Not Specified ] Street Address: City: State: Zip: Submittal Date: Mon Jan 27 16:11:40 EST 2014 Committee Statement Committee Statement: Update of extracted material from NFPA 30. Response Message:

5 of 37 5/30/2014 8:36 AM Second Revision No. 11-NFPA [ Section No ] Self-Propelled Equipment. Any unit that contains a motive power train as an integral part of the unit and is not rail mounted. [ 122, 2015]. Submitter Information Verification Submitter Full Name: [ Not Specified ] Organization: [ Not Specified ] Street Address: City: State: Zip: Submittal Date: Tue Jan 07 17:20:49 EST 2014 Committee Statement Committee Statement: Product of task group work - clarified that rail mounted equipment can be self-propelled. Response Message:

6 of 37 5/30/2014 8:36 AM Second Revision No. 18-NFPA [ Section No ] * Underground maintenance shops that are intended for use longer than 6 months shall be enclosed structures of fire-resistant construction, including floor, roof, roof supports, doors, and door frames, or shall be protected with an automatic sprinkler fire suppression system. (See for information on fixed fire suppression systems.) in accordance with Submitter Information Verification Submitter Full Name: Susan Bershad Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Mon Mar 31 12:05:25 EDT 2014 Committee Statement Committee Statement: This corrects an error in the current edition. Product of sprinkler task group. Response Message:

7 Second Revision No. 19-NFPA [ Section No ] General Requirements Mining equipment requiring a fixed fire protection system shall be protected by a system with the capacity to suppress the largest anticipated fires in the protected areas and shall meet the following criteria: (1) They shall be listed or approved for the purpose. (2) They shall be located or guarded so as to be protected against physical damage. (3)* They shall be actuated either automatically, manually, or both. (4)* They shall be provided with an agent distribution hose or pipe secured and protected against damage, including abrasion and corrosion, and shall be flame resistant. (5) They shall be provided with discharge nozzle blowoff caps or other devices or materials to prevent the entrance of moisture, dirt, or other material into the piping. The discharge nozzle protective device shall blow off, blow out, or open upon agent discharge. (6) * Water-based systems shall not be required to have nozzle blowoff caps as long as the nozzles are kept free of blockage at all times. (7) The fire protection system shall be installed so that system actuation causes shutdown of the protected equipment. (8) Discharge nozzles or sprinklers shall not be covered with any material that will reduce the effectiveness of the system Automatically actuated systems other than water-based sprinkler systems shall have a manual actuator capable of being activated from the operator's compartment or other accessible location Fire Unless otherwise noted in this standard, fire protection systems other than automatic sprinkler systems shall be installed and operate in accordance with the applicable NFPA standards Pre-engineered dry chemical or wet chemical systems shall be designed, installed, and tested in accordance with the fire suppression system manufacturer s listed installation and maintenance manual * Where the nature of a coal mine does not allow the NFPA standards to be followed, systems that provide equivalent protection shall be approved by the authority having jurisdiction. Supplemental Information File Name NFPA_120_ _SR_19_reviewed_SB_comments_final.docx Description Annex material Submitter Information Verification Submitter Full Name: Susan Bershad Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Mon Mar 31 12:24:12 EDT 2014 of 37 5/30/2014 8:36 AM

8 Annex Material for SR 19 A (6) Open head deluge and water spray systems can be kept free of blockage by regular flow of water through the system. For example, fire suppression on continuous miners can be flowed once per shift to keep the nozzles clean. Deluge water spray systems at belt drives can be flowed weekly to keep the nozzles clean.

9 of 37 5/30/2014 8:36 AM Committee Statement Committee Statement: Product of sprinkler system task group. Adds additional annex material. Response Message:

10 Second Revision No. 20-NFPA [ Section No ] Applications * The following equipment and facilities shall be protected by approved automatic fire protection systems. Where sprinkler systems are used, they shall satisfy the requirements of through Where dry chemical systems are used, they shall satisfy the requirements for self-propelled equipment in (1)* Drive areas of belt conveyors shall be protected in accordance with (2) Flammable and combustible liquid storage areas shall be protected by either one of the following: (a) (b) Automatic water-based fixed fire protection systems installed for the protection of Class I or Class II liquid storage areas shall be of the Class B foam water type. Fixed diesel or other Class II combustible liquid storage areas shall be protected with a dry chemical system or a system that provides equivalent protection according to the authority having jurisdiction. Maintenance shops shall be protected by an approved automatic fire protection system. (3) Unattended hydraulic equipment shall use fire-resistant hydraulic fluid. (4) Unattended electrical equipment such as enclosed electric motors, controls, transformers, rectifiers, battery chargers, and other equipment that does not have a hydraulic system shall be protected by an approved automatic fire protection system. (5) Unattended electrical equipment located on noncombustible material and spaced at least 0.61 m (2 ft) from coal or other combustible material shall not be required to be protected with an automatic fire suppression system. (6) Unattended electrical equipment located on noncombustible material and separated from coal or other combustible material by a fire-resistive layer or wall shall not be required to be protected with an automatic fire suppression system * Air Compressors. Air compressors with motors that exceed 5 horsepower shall be protected by an approved automatic fire protection system interlocked to shut down the power to the compressor and by one of the following: (1) A person in constant attendance, within the line of sight of the compressor, and equipped with a portable fire extinguisher (2) Containment within an enclosure that is constructed of noncombustible materials, ventilated to prevent overheating of the compressor, and designed to provide containment of any possible fire involving the compressor Submitter Information Verification Submitter Full Name: Susan Bershad Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Mon Mar 31 13:04:14 EDT 2014 Committee Statement of 37 5/30/2014 8:36 AM

11 0 of 37 5/30/2014 8:36 AM Committee Statement: Response Message: Requirement for maintenance shops is already covered in Adds battery charges to the list of electrical equipment.

12 Second Revision No. 24-NFPA [ Sections , , ] Sprinkler System Requirements * Automatic water-based fixed fire protection systems installed for the protection of Class I or Class II liquid storage areas shall be of the foam water type * Water Supply. The water supply shall have enough pressure and flow to provide sprinkler coverage as the sprinkler design is intended An approved strainer with a flush-out connection and a manual shutoff valve shall be provided at the point of the sprinkler system connection to the main water line An indicating, full-flow, slow-opening water control valve shall be located at the tap of the water line supplying the sprinkler system When the sprinkler system is put into operation, the slow-opening valve specified in shall be sealed or locked in the open position, or be provided with a supervisory alarm A pressure gauge shall be provided at the point of connection The water line from the water main to the sprinkler system shall be metallic The water line from the water main to the sprinkler system of a belt drive shall be flexible metal or reinforced nonmetal if excessive vibration could reduce the reliability of the sprinkler system Fittings and piping shall have a rated pressure higher than the anticipated maximum pressure on the system General Installation Requirements * Piping in sprinkler systems shall comply with NFPA 13, Standard for the Installation of Sprinkler Systems Nonmetallic pipe shall not be used downstream of the sprinkler control valve unless investigated and approved for this purpose Hangers supporting sprinkler piping shall be metallic At least one hanger shall be attached to each length of pipe * Sprinklers shall be standard orifice pendent, upright, or sidewall-type automatic sprinklers * For sprinkler systems installed to protect the equipment and facilities indicated in (2) through (6), sprinklers shall be spaced no more than 3.66 m (12 ft) apart, and the protection of any one sprinkler shall not exceed 9.3 m 2 (100 ft 2 ) * Sprinklers shall be located so that the discharge will not be obstructed Sprinkler deflectors shall be located at a distance below the roof of not less than 25.4 mm (1 in.) nor greater than 508 mm (20 in.). 1 of 37 5/30/2014 8:36 AM

13 Roof cavities containing combustible material such as wood or coal in the area to be protected shall be protected by installation of upright sprinklers within the cavity at the top of riser pipes so that the deflectors are within 508 mm (20 in.) of the roof Wet-pipe sprinkler systems shall not be used where chance of freezing exists Provisions shall be made to drain all parts of the system Drain connections shall be sized as shown in Table Table Table Sizes of Drain Connections Riser or Main Size Up to 2 in. Size of Drain Connection 3 4 in. or larger in. to in in. or larger 4 in. and larger 2 in. only For SI units, 1 in. = 25.4 mm Trapped piping sections shall be equipped with auxiliary drains or otherwise arranged to facilitate draining General Alarm Requirements for Sprinkler Systems A waterflow switch or alarm valve, with associated inspector's test connection, capable of detecting the flow through one opened sprinkler shall be installed in the piping feeding the sprinklers. (A) An inspector s test connection shall be provided at the end of the most remote line of the sprinkler system. (B) The inspector s test connection shall simulate one sprinkler head in operation for sprinkler systems other than belt drive systems. (C) In addition to (B), the inspector s test connection for belt drive systems shall simulate a minimum of eight sprinkler heads activating at the same time The alarm device shall be connected to an alarm system that will alarm at a constantly attended location. The alarm device shall provide a local audible and visual alarm The alarm system shall identify the sprinkler system involved In dry-pipe automatic sprinkler systems, the alarm system shall be actuated by flow through a dry-pipe valve a pressure switch associated with the trim on the dry-pipe device A paddle-type water flow switch shall not be used be installed in wet systems only * Where the requirements of Section 8.2 are satisfied by installing automatic sprinkler systems, such systems shall comply with the requirements of and An indicating, full-flow, slow-opening water control valve shall be located at the tap of the water line supplying the sprinkler system When the sprinkler system is put into operation, the slow-opening valve specified in shall be sealed in the open position A waterflow switch or alarm valve, with associated inspector's test connection, capable of detecting the flow through one opened sprinkler shall be installed in the piping feeding the sprinklers. 2 of 37 5/30/2014 8:36 AM

14 The alarm device shall be connected to an alarm system that will alarm at a constantly attended location The alarm system shall identify the sprinkler system involved In dry-pipe automatic sprinkler systems, the alarm system shall be actuated by flow through a dry-pipe valve A paddle-type water flow switch shall not be used * Sprinklers shall be standard orifice pendent, upright, or sidewall-type automatic sprinklers Sprinklers shall be installed in the upright position on a dry-pipe system * Sprinklers shall be located so that the discharge will not be obstructed For belt conveyors, the entire top belt surface shall be wetted Sprinkler deflectors shall be located at a distance below the roof of not less than 25.4 mm (1 in.) nor greater than 508 mm (20 in.) Roof cavities containing combustible material such as wood or coal in the area to be protected shall be protected by installation of upright sprinklers within the cavity at the top of riser pipes so that the deflectors are within 508 mm (20 in.) of the roof * Piping in sprinkler systems shall comply with NFPA 13, Standard for the Installation of Sprinkler Systems Nonmetallic pipe shall not be used downstream of the sprinkler control valve unless investigated and approved for this purpose Hangers supporting sprinkler piping shall be metallic At least one hanger shall be attached to each length of pipe Provision shall be made to drain all parts of the system Drain connections shall be sized as shown in Table Table Sizes of Drain Connections Riser or Main Size Size of Drain Connection Up to 2 in. 3 4 in. or larger in. to in in. or larger 4 in. and larger 2 in. only For SI units, 1 in. = 25.4 mm Trapped piping sections shall be equipped with auxiliary drains or otherwise arranged to facilitate draining Wet-pipe sprinkler systems shall not be used where chance of freezing exists Antifreeze System. 3 of 37 5/30/2014 8:36 AM

15 Where danger of freezing exists, sprinkler systems filled with antifreeze solution shall be permitted and shall meet the requirements of through and of NFPA * If automatic sprinkler systems are connected to public water supplies or to piping supplying water for drinking, antifreeze solutions other than water solutions of pure glycerine [chemically pure (CP) or U.S. Pharmacopeia (USP) 96.5 percent grade] or propylene glycol shall not be used The glycerine water and propylene glycol water mixtures provided in Table shall be permitted to be used. Table Properties of Water-Based Solutions Material Solution (by volume) Specific Gravity at 15.6 C (60 F) Freezing Point C F Glycerine (CP or USP grade) 50% water % water % water Propylene glycol 70% water % water % water % water CP: chemically pure; USP: U.S. Pharmacopeia 96.5%. Note: Based on a hydrometer scale to (subdivisions 0.002). 4 of 37 5/30/2014 8:36 AM

16 If automatic sprinkler systems are not connected to public water systems or to piping that supplies water for drinking, the commercially available materials shown in Table shall be permitted to be used in antifreeze solutions. Table Antifreeze Solutions to Be Used If Public Water Is Not Connected to Sprinklers Material Solution (by volume) Specific Gravity at 15.6 C (60 F) Freezing Point C F Glycerine* Diethylene glycol 50% water % water % water Ethylene glycol 61% water % water % water % water Propylene glycol* Calcium chloride 2.83 lb CaCl /gal 2 80% flake, fire protection grade water Add corrosion inhibitor of sodium bichromate, 1 4 oz/gal water 3.38 lb CaCl 2 /gal water 3.89 lb CaCl 2 /gal water 4.37 lb CaCl 2 /gal water 4.73 lb CaCl 2 /gal water 4.93 lb CaCl 2 /gal water For SI units, 1 lb/gal = kg/l. Note: Based on a hydrometer scale to (subdivisions 0.002). *See Table Free from magnesium chloride and other impurities * A soft-seat check valve shall be connected to the tee in the water line feeding the automatic sprinkler system The water control valve shall be connected close to the discharge side of the check valve A 6.35 mm ( 1 4 in.) soft-seat relief valve made of corrosion-resistant bronze or stainless steel shall be connected to the sprinkler piping near the shutoff valve The relief valve shall be set to open at a pressure of 1380 kpa (200 psi) above the maximum water-line pressure (i.e., the maximum system pressure) * A suitable air chamber shall be connected to the piping. 5 of 37 5/30/2014 8:36 AM

17 The connection port to the chamber shall be fitted with a small, high-pressure, corrosion-resistant ball valve The connection from the ball valve to the sprinkler piping shall be permitted to use a small-diameter hydraulic hose having a working pressure of at least the maximum system pressure The air chamber shall be filled with compressed air at a pressure equal to the maximum water-line pressure Where connected to the system piping, the air chamber shall be oriented so that the connection port is located at the bottom of the chamber With the shutoff valve still closed, the sprinkler piping shall be filled with the antifreeze solution, and the following procedures shall be performed: High points of the piping shall be vented to obtain reasonably complete filling. The valve on the air chamber shall be opened and sealed. If possible, the pressure of the antifreeze solution shall be raised to the line pressure before the shutoff valve is opened and sealed. Finally, the system shall be checked carefully for leaks * With all other fill, drain, and vent valves closed, a high-pressure air compressor shall be connected to a valve opening, and pressure in the piping shall be raised at least to the water-line pressure The valve at the opening shall be closed, and the valve shall be plugged The system shall be checked for leaks, especially in the area of the piping where the air is believed to exist If the pressure gauge shows that the system is still tight after 24 hours, the shutoff valve shall be opened, making the system operational The shutoff valve shall be sealed in the open position Sprinkler systems filled with antifreeze solution shall employ antifreeze solution mixtures that are rated for the lowest temperature to which the sprinkler system could be exposed * The antifreeze solution shall be mixed and tested before being pumped into the sprinkler system piping A pressure gauge shall be provided in a protected location on the downstream side of the shutoff valve * Dry-Pipe System. Where danger of freezing exists, a dry-pipe sprinkler system shall be permitted and shall meet the requirements of through The dry-pipe valve and its accessories shall be installed in a separate area and shall be protected against freezing and mechanical injury If the separate area described in is ventilated with return air, all electrical components shall be permissible or intrinsically safe Water pressure shall be regulated not to exceed the maximum pressure specified by the manufacturer of the dry-pipe valve. 6 of 37 5/30/2014 8:36 AM

18 The dry-pipe valve shall be installed in accordance with the manufacturer's instructions Mechanical grooved couplings, including gaskets used on dry-pipe systems, shall be listed for dry-pipe service Operation of the dry-pipe system and supervision of the system, including pressure of the air supply, shall be signaled to an attended location. Signaling to an attended location shall be permitted to utilize alarm systems serving fire detection equipment The system air supply shall be provided from a reliable source such as a dedicated compressor and shall be equipped with an air maintenance device Sprinklers shall be installed in the upright position on a dry-pipe system or be listed dry type or horizontal sidewall sprinklers installed according to the listing for dry-pipe systems Protection of Specific Hazards * Automatic water-based fixed fire protection systems installed for the protection of Class I or Class II liquid storage areas shall be of the foam water type * Where the requirements of Section dealing with underground belt drives are satisfied by installing automatic sprinkler systems, such systems shall comply with the requirements of and and Automatic Sprinkler System Acceptance Testing Flushing of Water-Line Connections Water-line connections and lead-in connections shall be flushed at the maximum flow rate available before connection is made to the sprinkler piping in order to remove foreign material Flushing shall be continued until the water is clear Flow Testing of Sprinkler Systems Wet-pipe closed automatic sprinkler systems shall be flow-tested by operating flow through the maximum number of sprinklers expected to open, but not through fewer than eight open sprinklers at least one sprinkler head for non belt drive areas and at least eight sprinkler heads for belt drive areas If the system contains fewer than eight sprinklers, all sprinklers or an inspector s test simulating all sprinklers shall be flow-tested as specified in If With a water flow and pressure that is present under normal mine operating conditions, if the residual pressure measured downstream of the opened sprinklers is 70 kpa (10 psi) or greater for belt drive systems and 140 kpa (20 psi) for all other systems, the system shall be considered acceptable Closed sprinkler systems installed to protect areas where the water discharge could damage the area or its contents shall not be required to be tested by operating flow through opened sprinklers Where the condition(s) in exist, the alternative test of operating flow through a 51 mm (2 in.) valve test connection shall be permitted to be used Portable sprinkler systems that are dismantled and reinstalled in new areas shall be flow-tested following the initial installation Tests of Dry-Pipe Sprinkler Systems Where there is no risk of freezing, new dry-pipe systems shall be flow-tested and hydrostatically tested in accordance with NFPA 13, Standard for the Installation of Sprinkler Systems. 7 of 37 5/30/2014 8:36 AM

19 A dry-pipe valve shall be tested according to the manufacturer's recommendations * Where there is risk of freezing in dry-pipe systems, an air pressure of 276 kpa (40 psi) shall be pumped up and allowed to stand 24 hours, and all leaks that allow a loss of pressure over 10.3 kpa (1 1 2 psi) during the 24 hours shall be stopped Sprinkler System Maintenance All sprinkler systems shall be maintained in accordance with the manufacturer's requirements or in accordance with NFPA 25, Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems As a minimum, all closed sprinkler systems, except antifreeze systems, shall be retested annually by operating flow through the end fitting in all lines to remove any silt buildup If pendent sprinklers are used on wet-type sprinkler systems, the end sprinkler on each line shall be removed and examined annually to check for silt buildup If silt buildup is found, all sprinklers on the line shall be removed, the line flushed, and new sprinklers installed Antifreeze Systems. (A) Each year at the onset of freezing weather, a small amount of antifreeze shall be drawn from the drain valve and the test valve(s) and tested with a hydrometer to ensure that the solution is suitable for the lowest temperature expected. (B) If the test described in (A) shows that the solution is not suitable, the solution shall be replaced Inspection, Maintenance, and Testing All fire suppression systems shall be tested after installation in accordance with the appropriate NFPA standard If an applicable NFPA standard does not exist, then a fire suppression system shall be tested in accordance with the manufacturer's or designer's instruction manual Testing shall not require the discharge of suppressant unless there is no other satisfactory manner in which the reliability and integrity of the system can be verified * All persons who inspect, test, operate, or maintain fire suppression systems shall be trained Sprinkler System Maintenance All sprinkler systems shall be maintained in accordance with the manufacturer's requirements or in accordance with NFPA 25, Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems * As a minimum, all closed-head sprinkler systems, except antifreeze systems, shall be retested flushed annually by operating flow through the end fitting in all lines of the line drain(s) for the system to remove any silt buildup. (A) If pendent sprinklers are used on wet-type sprinkler systems, the end sprinkler on each line shall be removed and examined annually to check for silt buildup. (B) If silt buildup is found, all sprinklers on the line shall be removed, the line flushed, and new sprinklers installed. 8 of 37 5/30/2014 8:36 AM

20 * As a minimum, deluge sprinklers and deluge water-spray systems shall be flow-tested on a monthly basis The strainer shall be flushed on a weekly basis, at a minimum Antifreeze Systems. (A) Each year at the onset of freezing weather, a small amount of antifreeze shall be drawn from the drain valve and the test valve(s) and tested with a hydrometer to ensure that the solution is suitable for the lowest temperature expected. (B) If the test described in (A) (A) shows that the solution is not suitable, the solution shall be replaced Fire suppression systems, alarms, and interlocks shall be inspected at least weekly and maintained in accordance with the appropriate NFPA standard. If an applicable NFPA standard does not exist, then the fire suppression system, alarm, and interlock shall be examined and checked thoroughly for proper operation in accordance with the manufacturer's or designer's manual * All persons who inspect, test, operate, or maintain fire suppression systems shall be trained. Supplemental Information File Name NFPA_120_4_3_3_3_SR-24_clean_reviewed_SB_comments.docx NFPA_120_A_4_3_3_3_SR-24_clean_reviewed_SB_comments.docx Description Annex material Submitter Information Verification Submitter Full Name: Susan Bershad Organization: National Fire Protection Assoc Street Address: City: State: Zip: Submittal Date: Wed Apr 02 10:53:46 EDT 2014 Committee Statement Committee Statement: Response Message: The sprinkler task group has revised and reorganized this section. Most of the following section is just reorganized in a more logical manner for ease of readership. The section on water supply is added as the current edition does not have specifics on the requirements for water supply systems. Note that the entire section on antifreeze systems has been deleted and now just refers to the requirements in NFPA 13. Flow testing of sprinkler system was originally written only for belt drive areas. It is now expanded to include all areas with sprinkers. The non-belt drive areas need different requirements. 9 of 37 5/30/2014 8:36 AM

21 SR 24 moved text for through Sprinkler System Requirements * Water Supply. The water supply shall have enough pressure and flow to provide sprinkler coverage as the sprinkler design is intended An approved strainer with a flush-out connection and a manual shutoff valve shall be provided at the point of the sprinkler system connection to the main water line An indicating, full-flow, slow-opening water control valve shall be located at the tap of the water line supplying the sprinkler system When the sprinkler system is put into operation, the slow-opening valve specified in shall be sealed or locked in the open position, or be provided with a supervisory alarm A pressure gauge shall be provided at the point of connection The water line from the water main to the sprinkler system shall be metallic The water line from the water main to the sprinkler system of a belt drive shall be flexible metal or reinforced nonmetal if excessive vibration could reduce the reliability of the sprinkler system Fittings and piping shall have a rated pressure higher than the anticipated maximum pressure on the system General Installation Requirements * Piping in sprinkler systems shall comply with NFPA Nonmetallic pipe shall not be used downstream of the sprinkler control valve unless investigated and approved for this purpose Hangers supporting sprinkler piping shall be metallic.

22 At least one hanger shall be attached to each length of pipe * Sprinklers shall be standard orifice pendent, upright, or sidewall-type automatic sprinklers * For sprinkler systems installed to protect the equipment and facilities indicated in (2) through (7), sprinklers shall be spaced no more than 3.66 m (12 ft) apart, and the protection of any one sprinkler shall not exceed 9.3 m 2 (100 ft 2 ) * Sprinklers shall be located so that the discharge will not be obstructed Sprinkler deflectors shall be located at a distance below the roof of not less than 25.4 mm (1 in.) nor greater than 508 mm (20 in.) Roof cavities containing combustible material such as wood or coal in the area to be protected shall be protected by installation of upright sprinklers within the cavity at the top of riser pipes so that the deflectors are within 508 mm (20 in.) of the roof Wet-pipe sprinkler systems shall not be used where chance of freezing exists Provisions shall be made to drain all parts of the system Drain connections shall be sized as shown in Table Table Sizes of Drain Connections Riser or Main Size Size of Drain Connection Up to 2 in. ¾ in. or larger 2½ in. to 3½ in. 1¼ in. or larger 4 in. and larger 2 in. only For SI units, 1 in. = 25.4 mm Trapped piping sections shall be equipped with auxiliary drains or otherwise arranged to facilitate draining General Alarm Requirements for Sprinkler Systems.

23 A waterflow switch or alarm valve capable of detecting the flow through one opened sprinkler shall be installed in the piping feeding the sprinklers. (A) An inspector s test connection shall be provided at the end of the most remote line of the sprinkler system. (B) The inspector s test connection shall simulate one sprinkler head in operation for sprinkler systems other than belt drive systems. (C) In addition to (B), the inspector s test connection for belt drive systems shall simulate a minimum of eight sprinkler heads activating at the same time The alarm device shall be connected to an alarm system that will alarm at a constantly attended location. The alarm device shall provide a local audible and visual alarm The alarm system shall identify the sprinkler system involved In dry-pipe automatic sprinkler systems, the alarm system shall be actuated by a pressure switch associated with the trim on the dry-pipe device A paddle-type water flow switch shall be installed in wet systems only Antifreeze System. Where danger of freezing exists, sprinkler systems filled with antifreeze solution shall be permitted and shall meet the requirements of and of NFPA * Dry-Pipe System. Where danger of freezing exists, a dry-pipe sprinkler system shall be permitted and shall meet the requirements of through The dry-pipe valve and its accessories shall be installed in a separate area and shall be protected against freezing and mechanical injury

24 If the separate area described in is ventilated with return air, all electrical components shall be permissible or intrinsically safe Water pressure shall be regulated not to exceed the maximum pressure specified by the manufacturer of the dry-pipe valve The dry-pipe valve shall be installed in accordance with the manufacturer's instructions Mechanical grooved couplings, including gaskets used on dry-pipe systems, shall be listed for dry-pipe service Operation of the dry-pipe system and supervision of the system, including pressure of the air supply, shall be signaled to an attended location. Signaling to an attended location shall be permitted to utilize alarm systems serving fire detection equipment The system air supply shall be provided from a reliable source such as a dedicated compressor and shall be equipped with an air maintenance device Sprinklers shall be installed in the upright position on a dry-pipe system or be listed dry type or horizontal sidewall sprinklers installed according to the listing for dry-pipe systems Protection of Specific Hazards * Automatic water-based fixed fire protection systems installed for the protection of Class I or Class II liquid storage areas shall be of the foam water type * Where the requirements of dealing with underground belt drives are satisfied by installing automatic sprinkler systems, such systems shall comply with the requirements of and Automatic Sprinkler System Acceptance Testing Flushing of Water-Line Connections Water-line connections and lead-in connections shall be flushed at the maximum flow rate available before connection is made to the sprinkler piping in order to remove foreign material.

25 Flushing shall be continued until the water is clear Flow-Testing of Sprinkler Systems Wet-pipe closed automatic sprinkler systems shall be flow-tested by operating flow through at least one sprinkler head for non belt drive areas and at least eight sprinkler heads for belt drive areas If the system contains fewer than eight sprinklers, all sprinklers or an inspector s test simulating all sprinklers shall be flow-tested as specified in With a water flow and pressure that is present under normal mine operating conditions, if the residual pressure measured downstream of the opened sprinklers is 70 kpa (10 psi) or greater for belt drive systems and 140 kpa (20 psi) for all other systems, the system shall be considered acceptable Closed sprinkler systems installed to protect areas where the water discharge could damage the area or its contents shall not be required to be tested by operating flow through opened sprinklers Where the condition(s) in exist, the alternative test of operating flow through a 51 mm (2 in.) valve test connection shall be permitted to be used Portable sprinkler systems that are dismantled and reinstalled in new areas shall be flow-tested following the initial installation Tests of Dry-Pipe Sprinkler Systems Where there is no risk of freezing, new dry-pipe systems shall be flow-tested and hydrostatically tested in accordance with NFPA A dry-pipe valve shall be tested according to the manufacturer's recommendations * Where there is risk of freezing in dry-pipe systems, an air pressure of 276 kpa (40 psi) shall be pumped up and allowed to stand 24 hours, and all leaks that allow a loss of pressure over 10.3 kpa (1½ psi) during the 24 hours shall be stopped.

26 Inspection, Maintenance, and Testing All fire suppression systems shall be tested after installation in accordance with the appropriate NFPA standard If an applicable NFPA standard does not exist, then a fire suppression system shall be tested in accordance with the manufacturer's or designer's instruction manual Testing shall not require the discharge of suppressant unless there is no other satisfactory manner in which the reliability and integrity of the system can be verified * All persons who inspect, test, operate, or maintain fire suppression systems shall be trained Sprinkler System Maintenance All sprinkler systems shall be maintained in accordance with the manufacturer's requirements or in accordance with NFPA * As a minimum, all closed-head sprinkler systems, except antifreeze systems, shall be flushed annually by operating flow through the end of the line drain(s) for the system to remove any silt buildup. (A) If pendent sprinklers are used on wet-type sprinkler systems, the end sprinkler on each line shall be removed and examined annually to check for silt buildup. (B) If silt buildup is found, all sprinklers on the line shall be removed, the line flushed, and new sprinklers installed * As a minimum, deluge sprinklers and deluge water-spray systems shall be flow-tested on a monthly basis The strainer shall be flushed on a weekly basis, at a minimum Antifreeze Systems.

27 (A) Each year at the onset of freezing weather, a small amount of antifreeze shall be drawn from the drain valve and the test valve(s) and tested with a hydrometer to ensure that the solution is suitable for the lowest temperature expected. (B) If the test described in (A) shows that the solution is not suitable, the solution shall be replaced.

28 SR 24 Annex material A NFPA 13 requires a minimum 140 kpa (20 psi) residual pressure for ordinary hazard pipe schedule sprinkler systems. A Pipe and fittings that permit limited motion of the pipe are recommended as they allow the pipe to be held closer to the roof. If threaded fittings are used, steel pipe with extra strength threaded fittings is recommended. Copper, aluminum, or other approved materials could be permitted if they are adequate for the pressure. A number of mines use aluminum pipe or tubing with groove type couplings and fittings. Where water pressure does not exceed 3448 kpa (500 psi), grooved couplings that have a 12.7 mm (½ in.) female national pipe thread (FNPT) outlet are used to provide connections for sprinklers. Piping put together in this manner can be located closer to an undulating roof, especially if the pipe lengths are short enough to put the couplings (and the automatic sprinklers) on 3 m (10 ft) centers. Mines that use groove type couplings can have most of the piping precut and grooved in the shop, which simplifies installation underground. Rolled grooves are recommended because they do not reduce the strength of the pipe as much as the cut grooves do. If cut grooves are used, Schedule 40 or heavier pipe should be used. A Some automatic sprinklers might not withstand the water pressure that can be encountered in deep mines. Information on the effect of high water pressure on automatic sprinklers can be found in U.S. Bureau of Mines Report of Investigation 9451, Effect of Pressure on Leakage of Automatic Sprinklers. Under U.S. Bureau of Mines Report of Investigation 9538, Performance of Automatic Sprinkler Systems for Extinguishing Incipient and Propagating Conveyor Belt Fires Under Ventilated Conditions, NIOSH conducted a series of full scale fire tests under ventilated conditions of 1.1 and 4.0 m/s (225 and 800 ft/min) for fires up to 10.8 MW. The tests demonstrated that pendent and horizontal sidewall types were both able to extinguish incipient belt fires. Directional sprinklers showed a slightly improved performance in terms of maximum heat release rate at the lower airflow. Both pendent and horizontal sidewall sprinkler types were able to extinguish propagating fires. Horizontal sidewall sprinklers showed an increased effectiveness compared to the pendent sprinklers because of the increased upstream coverage area of the water discharge in terms of maximum heat release rate. A The restrictions on sprinkler spacing apply to sprinklers on the same line and those located between sprinklers on adjacent lines. A

29 Where sprinkler positioning is such that full coverage can be impaired, such as where a single line of sprinklers protects a belt conveyor with little clearance, a flow test should be conducted to determine if adequate wetting of surface areas is achieved. Additional sprinklers should be provided in the event that adequate coverage is not achieved, or alternative arrangements such as rotated lines or sidewall sprinklers should be considered. Consideration also should be given to the need for noncombustible baffles to protect sprinklers from the discharge of adjacent sprinklers located within 1.8 m (6 ft). A Dry pipe automatic sprinkler systems are more complex and more difficult to design and install than wet pipe systems. The committee recommends that all systems be designed and installed by skilled and experienced personnel. A pressure relief valve, set to relieve at a pressure below the maximum pressure rating of the dry pipe valve, should be installed between the pressure regulating valve and the dry pipe valve. The reclosing pressure of the relief valve should be higher than the set pressure of the regulating valve. A Underground shaft mines that use diesel powered equipment generally employ underground diesel fuel storage areas to facilitate equipment refueling. Adit type mines in the western United States might initially locate diesel fuel storage and refueling facilities on the surface; however, as the active mine workings progress farther from the adit portal(s), these facilities will likely be moved underground. A common means of fire protection in many underground diesel fuel storage areas is the use of fixed water sprinkler systems. However, this situation represents a significant safety hazard. According to the NFPA Fire Protection Handbook, water sprinklers can be permitted to be used on diesel fuel for control but not for extinguishment. In The Health and Safety Implications of the Use of Diesel Powered Equipment in Underground Mines, a report by an interagency task group prepared for MSHA in 1985, the simple conclusion was that water spray or fog usually will not extinguish diesel fuel fires. In an underground coal mine, fire control is not sufficient; fire extinguishment is essential for the following reasons: (1) Unlike an underground metal or nonmetal mine, the mineral in a coal mine is combustible. All fire prevention and protection provisions in an underground coal mine are aimed at preventing the ignition of the coal. In a metal or nonmetal mine, if fire control efforts are unsuccessful in extinguishing a fire on a piece of diesel equipment or a diesel fuel fire, personnel can be evacuated and the fire can be allowed to consume all available fuel materials, thereby selfextinguishing. In an underground coal mine, this practice would almost certainly result in the ignition of the coal and the consequent loss of part or all of the mine. (2) Even if a fire does not grow in intensity or spread to the coal, toxic smoke and fire gases are produced as long as it burns, which can endanger persons within the mine. (3) According to the NFPA Fire Protection Handbook, overpressure failure of containers exposed to fire is considered the principal hazard of closed container flammable and combustible liquid storage.

30 (4) Even a controlled fire can cause such container failure, producing a fire so intense that the sprinkler system is unable to control it, much less extinguish it. (5) Water sprays are not effective in extinguishing pressure fires, running fuel fires, and obstructed spill fires, all of which could occur in a diesel refueling area. (6) Water supplies are limited in many underground mines. Fire control should be considered temporary because when the water supply is depleted, the fire will grow immediately to the maximum intensity. (7) The vapor pressure of diesel fuel increases with elevation due to reduced barometric pressure. As a result, even fuels without flash point reducing additives can become flammable, depending on the altitude at which they are used. This reduction in flash point can result in reclassification of the diesel fuel to a Class IC flammable liquid. There is no clear consensus in the literature and industry practice as to the effectiveness of fixed water sprays in controlling and extinguishing fires involving Class IC flammable liquids. Although industry practice strongly favors fixed water sprays for such applications, the literature and available research results clearly indicate the ineffectiveness of fixed sprays on Class IC liquids, especially in the case of pressure fires, running fuel fires, and obstructed spill fires. Therefore, water sprinkler systems installed for the protection of diesel fuel storage areas are considered inadequate; foam water systems should be utilized. See the applicable sections of NFPA 16. A The alarm system that serves sprinklers protecting the drive area of a belt conveyor also should be permitted to serve as the fire detection system installed over that portion of the belt conveyor. A The clapper of a differential type dry pipe valve should be held off its seat during any test in excess of 345 kpa (50 psi), to prevent damaging the valve. A The special suppression system manufacturer is a good source for training regarding their equipment. Other acceptable training resources can be available. A The system could have several end of line drains if parts of the system dead end. A Deluge sprinklers might need to be flowed more frequently than monthly to keep the sprinkler systems clean. If caps are not used on water spray systems, they also might need to be flowed more frequently than monthly to keep the nozzles clean.

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal Ontario Fire Code SECTION 5.13 DIP TANKS Illustrated Commentary Office of the Ontario Fire Marshal Dip Tanks Illustrated Commentary 1 5.13.1. Location 5.13.1.1. Dip tank operations involving flammable

More information

Model: 400E-2M. Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset. Installation Operation Maintenance. Application Engineering

Model: 400E-2M. Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset. Installation Operation Maintenance. Application Engineering Model: 400E-2M Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset Installation Operation Maintenance Application Engineering BERMAD 1. Safety First BERMAD believes that the safety

More information

BERMAD Fire Protection

BERMAD Fire Protection Model: 400E-2M BERMAD Electrically Controlled Deluge Valve with Easy Lock Manual Reset Installation Operation Maintenance Safety First BERMAD believes that the safety of personnel working with and around

More information

BERMAD Fire Protection

BERMAD Fire Protection 400E-2M/700E-2M IOM Bermad Electrically Controlled Deluge Valve with EasyLock Manual Reset Model: 400E-2M/700E-2M INSTALLATION OPERATION MAINTENANCE Application Engineering BERMAD 400E-2M/700E-2M Bermad

More information

NFPA31FuelOilPiping 1 Revised 3-1-11

NFPA31FuelOilPiping 1 Revised 3-1-11 NFPA 31 Fuel Oil Piping, Installation and Testing Chapter 8 Fuel Piping Systems and Components 8.1 Scope. This chapter shall apply to piping systems and their components used to transfer fuel oil from

More information

OREGON FIRE CODE Interpretations and Technical Advisories

OREGON FIRE CODE Interpretations and Technical Advisories OREGON FIRE CODE Interpretations and Technical Advisories A collaborative service by local and state fire professionals, along with our stakeholders and customers, to provide consistent and concise application

More information

SELF-INSPECTION PROGRAM FOR FIRE PROTECTION EQUIPMENT

SELF-INSPECTION PROGRAM FOR FIRE PROTECTION EQUIPMENT SELF-INSPECTION PROGRAM FOR FIRE PROTECTION EQUIPMENT INTRODUCTION No matter how reliable fire protection equipment may seem, periodic maintenance is needed to ensure proper operation. Fire protection

More information

Risk Control Bulletin Inspection, Testing & Maintenance (ITM) of Water-Based Fire Protection Systems

Risk Control Bulletin Inspection, Testing & Maintenance (ITM) of Water-Based Fire Protection Systems Risk Control Bulletin Inspection, Testing & Maintenance (ITM) of Water-Based Fire Protection Systems Introduction Fire protection systems are provided in or at a building to safeguard the lives of building

More information

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

ELECTRIC/DIESEL FIRE PUMP CHECK LIST BUILDING NAME: DESIGNER: SCO REPRESENTATIVE: PUMP MANUF.: LOCATION: INSTALLER: DATE: OWNER NAME: INSTALLATION Certificate for flushing and hydrostatic test furnished Piping been hydrostatically tested

More information

3", 4", 6" & 8" Model H Series Alarm Check Valve Installation and Maintenance Guide

3, 4, 6 & 8 Model H Series Alarm Check Valve Installation and Maintenance Guide ", ", " & " Model H Series Alarm Check Valve Installation and Maintenance Guide 077 AIRPARK DRIVE STANDISH, MICHIGAN PHONE 99-- 00-2-0 FAX 99--92 www.globesprinkler.com OCTOBER 2 C- BULLETIN A.C.V.I.M.,

More information

INSPECTION, TESTING AND MAINTENANCE OF FIRE PROTECTION SYSTEMS AND EQUIPMENT

INSPECTION, TESTING AND MAINTENANCE OF FIRE PROTECTION SYSTEMS AND EQUIPMENT CITY OF SPRING LAKE PARK Code Enforcement Department 1301 81 st Avenue NE Spring Lake Park MN 55432 Business Phone 763-784-6491 Fax 763-792-7257 INSPECTION, TESTING AND MAINTENANCE OF FIRE PROTECTION SYSTEMS

More information

Antifreeze Solutions in Residential Fire Sprinkler Systems

Antifreeze Solutions in Residential Fire Sprinkler Systems Antifreeze Solutions in Residential Fire Sprinkler Systems The 2013 edition of NFPA 13D, as amended by TIA 13 1, discourages the use of antifreeze solutions within residential fire sprinkler systems unless

More information

Inspection and Testing of Water-Based Systems

Inspection and Testing of Water-Based Systems Inspection and Testing of Water-Based Systems Standard Model/Computer-Based Testing Level III Content Outline The candidate for NICET certification at Level III in the Inspection and Testing of Water-Based

More information

The following definitions apply with regard to requirements specified in this document:

The following definitions apply with regard to requirements specified in this document: GUIDELINES FOR INSTALLATION OF TEMPORARY AND PERMANENT ABOVEGROUND DIESEL FUEL TANKS FOR EMERGENCY AND STANDBY POWER SYSTEMS LOCATED OUTSIDE OF BUILDINGS For Use by Unidocs Member Agencies or where approved

More information

Automatic Fire Sprinkler Submittal Requirements

Automatic Fire Sprinkler Submittal Requirements Automatic Fire Sprinkler Submittal Requirements All commercial and industrial buildings with a total floor area of 5000 sq. ft. shall have an approved automatic sprinkler system installed. The Windsor-Severance

More information

FIVE YEAR CERTIFICATION REPORT

FIVE YEAR CERTIFICATION REPORT GARDEN GROVE FIRE DEPARTMENT FIRE PREVENTION DIVISION FIVE YEAR CERTIFICATION REPORT Service and maintenance report of automatic fire extinguishing systems, including fire sprinklers, dry, deluge, and

More information

Fire Pump Plan Review March 2010

Fire Pump Plan Review March 2010 Fire Pump Plan Review March 2010 Date of Review: / / Permit Number: Business/Building Name: Address of Project: Designer Name: Designer s Phone: Contractor: Contractor s Phone: Occupancy Classification:

More information

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS TYPICAL FIRE SAFETY INSPECTION VIOLATIONS The following is a list of typical violations often found by inspectors and a generic solution. You can use this list to improve the safety of your facility, to

More information

Important Ontario Fire Code Information for Building Owners in the City of Windsor

Important Ontario Fire Code Information for Building Owners in the City of Windsor Important Ontario Fire Code Information for Building Owners in the City of Windsor This information is intended to be used a reference only. For a complete listing consult the Ontario Fire Code or contact

More information

TECHNICAL ADVISORY BULLETIN

TECHNICAL ADVISORY BULLETIN RISK CONTROL AND CLAIM ADVOCACY PRACTICE TECHNICAL ADVISORY BULLETIN November 2014 www.willis.com FIRE PUMP TESTING Fire pumps are a critical part of a fire protection system, especially when they are

More information

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION Fire Pump Plan Review 2009 International Fire Code and NFPA 20 Date of Review / / BLD201 - Project Address: Project Name: Contractor s Business

More information

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST RESIDENTIAL FIRE SPRINKLERS NFPA 13D

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST RESIDENTIAL FIRE SPRINKLERS NFPA 13D July 1, 2010 SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST RESIDENTIAL FIRE SPRINKLERS NFPA 13D Address: Permit #: Inspector: Date: Status: Inspector: Date: Status: A-Approved;

More information

The following definitions apply with regard to requirements specified in this document:

The following definitions apply with regard to requirements specified in this document: GUIDELINES FOR INSTALLATION OF TEMPORARY AND PERMANENT ABOVEGROUND DIESEL FUEL TANKS FOR EMERGENCY AND STANDBY POWER SYSTEMS LOCATED OUTSIDE OF BUILDINGS For Use by Unidocs Member Agencies or where approved

More information

MAINTENANCE AND SERVICE OF AUTOMATIC FIRE EXTINGUISHING SYSTEMS

MAINTENANCE AND SERVICE OF AUTOMATIC FIRE EXTINGUISHING SYSTEMS FIRE DEPARTMENT Bureau of Fire Protection and Life Safety www.cityofsanmateo.org 1900 O Farrell, Suite 140 San Mateo, CA 94403-1332 (650) 522-7940 FAX: (650) 522-7941 TDD: (650) 522-7047 MAINTENANCE AND

More information

FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST

FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST Date of Inspection: Conducted by: Location: Reviewed by: Date of Review: Comments or additional corrective action taken as a result

More information

CHAPTER. Standpipes and Hose Systems OVERVIEW. Standpipe and Hose Systems Defined

CHAPTER. Standpipes and Hose Systems OVERVIEW. Standpipe and Hose Systems Defined Standpipes and Hose Systems CHAPTER 3 This chapter, which opens with an overview of standpipe and hose systems, is intended to assist the registered design professional (RDP), commissioning agent, authority

More information

FIRE PROTECTION SYSTEMS ACCEPTANCE INSPECTION AND TESTING PROCEDURE

FIRE PROTECTION SYSTEMS ACCEPTANCE INSPECTION AND TESTING PROCEDURE ACCEPTANCE INSPECTION AND TESTING PROCEDURE Wet Pipe Sprinkler Systems...2 Dry Pipe Sprinkler Systems...2 Clean Agent Fire Extinguishing System...4 Total Flooding Systems...4 Fire Dampers...5 Smoke Dampers...5

More information

Fire Sprinkler System Maintenance and Testing Page 1 MAINTENANCE AND TESTING OF FIRE SPRINKLER SYSTEMS

Fire Sprinkler System Maintenance and Testing Page 1 MAINTENANCE AND TESTING OF FIRE SPRINKLER SYSTEMS Page 1 MAINTENANCE AND TESTING OF FIRE SPRINKLER SYSTEMS Introduction When properly installed and maintained, automatic fire sprinkler systems have proven to be the most effective means for protecting

More information

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST RESIDENTIAL FIRE SPRINKLERS NFPA 13R

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST RESIDENTIAL FIRE SPRINKLERS NFPA 13R July 1, 2010 SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST RESIDENTIAL FIRE SPRINKLERS NFPA 13R Address: Permit #: Inspector: Date: Status: Inspector: Date: Status: A-Approved;

More information

Notes. Material 1. Appropriate Flammable Liquids

Notes. Material 1. Appropriate Flammable Liquids 29 CFR 1910.106 Flammable Materials Flammable Liquids Preparation 1. Read Applicable Background information and related Company Policy Chapter. 2. Make Copies of this Lesson Plan for Personnel 3. Make

More information

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES These guidelines are to be used for ALL commercial cooking hoods, ventilation systems and related fire suppression

More information

Clark County Fire Prevention

Clark County Fire Prevention Clark County Fire Prevention Mission Statement: To provide the highest level of fire protection and related services TITLE: REQUIREMENTS FOR A NEW SPRINKLER SYSTEM IN ACCORDANCE WITH THE 2002 EDITION OF

More information

Winnipeg Fire Department Fire Prevention Branch

Winnipeg Fire Department Fire Prevention Branch Winnipeg Fire Department Fire Prevention Branch Manitoba Fire Code Life-Safety Equipment Maintenance Requirements The Fire Prevention Branch of the Winnipeg Fire Department has prepared this document of

More information

ALBERTA FIRE CODE SAFETY EQUIPMENT MAINTENANCE REQUIREMENTS

ALBERTA FIRE CODE SAFETY EQUIPMENT MAINTENANCE REQUIREMENTS ALBERTA FIRE CODE SAFETY EQUIPMENT MAINTENANCE REQUIREMENTS In this document are the fire safety equipment maintenance requirements that are found in Division B of the Alberta Fire Code (AFC 2006) for

More information

Morrison Bros. Co. General Product Specifications

Morrison Bros. Co. General Product Specifications Morrison Bros. Co. General Product Specifications Tank Mounted Spillbox The spill containment device is manufactured to contain spills and drips that may occur at the fill point on aboveground storage

More information

Fire Alarm System Standpipes Sprinkler Systems Fire Drills Commercial Cooking Hood and more

Fire Alarm System Standpipes Sprinkler Systems Fire Drills Commercial Cooking Hood and more FIRE PROTECTION SYSTEMS Fire protection systems, measures and equipment are all related to the safety of the occupants and the protection of the property. As part of a building design and its intended

More information

FLAMMABLE AND COMBUSTIBLE LIQUIDS. n OSHA Changes

FLAMMABLE AND COMBUSTIBLE LIQUIDS. n OSHA Changes FLAMMABLE AND COMBUSTIBLE LIQUIDS OSHA Changes Introduction This module covers the two primary hazards associated with flammable and combustible liquids: explosion and fire. In order to prevent these hazards,

More information

COMPRESSED GASES. 1.2 The contents of each cylinder and container must be clearly identified (by tag or stamp) on the cylinder.

COMPRESSED GASES. 1.2 The contents of each cylinder and container must be clearly identified (by tag or stamp) on the cylinder. Page 1 of 5 COMPRESSED GASES A compressed gas is defined as any mixture of gases in a container with a pressure exceeding 40 psi. at 70 o F, or 104 psi. at 130 o F; or any flammable liquid with an absolute

More information

General Fire Code Requirements Within Commercial Tenant Spaces

General Fire Code Requirements Within Commercial Tenant Spaces FIRE DEPARTMENT in cooperation with Scope: General Fire Code Requirements Within Commercial Tenant Spaces This handout is designed to assist owners, architects, contractors and others in understanding

More information

MOTOR FUEL DISPENSING SAFETY

MOTOR FUEL DISPENSING SAFETY STRATEGIC OUTCOMES PRACTICE TECHNICAL ADVISORY BULLETIN January 2010 MOTOR FUEL DISPENSING SAFETY Fire! Not an alarm anyone wants to hear, especially not when the fire is burning at a major fuel source.

More information

Ethanol Vehicle and Infrastructure Codes and Standards Citations

Ethanol Vehicle and Infrastructure Codes and Standards Citations Ethanol Vehicle and Infrastructure Codes and Standards Citations This document lists codes and standards typically used for U.S. ethanol vehicle and infrastructure projects. To determine which codes and

More information

EMERGENCY ACTION, EVACUATION AND FIRE PREVENTION SAFETY PROGRAM

EMERGENCY ACTION, EVACUATION AND FIRE PREVENTION SAFETY PROGRAM EMERGENCY ACTION, EVACUATION AND FIRE PREVENTION SAFETY PROGRAM REGULATORY STANDARD: OSHA - 29CFR1910.36-29CFR1910.38-29CFR1910.157-29CFR1910.165 NFPA-10 BASIS: The OSHA Emergency Action Planning and the

More information

Potter Electric Sprinkler Monitoring Training Manual

Potter Electric Sprinkler Monitoring Training Manual R Potter Electric Sprinkler Monitoring Training Manual 1 #8704200D 2 Contents Foreword... 4 Introduction... 5 Fire Alarm Signals... 6 Types Of Sprinkler Systems... 7 Wet Pipe Sprinkler Systems... 8 Straight

More information

PLAN SUBMITTAL REQUIREMENTS FOR SPRAY BOOTHS AND SPRAYING ROOMS EXTINGUISHING SYSTEMS

PLAN SUBMITTAL REQUIREMENTS FOR SPRAY BOOTHS AND SPRAYING ROOMS EXTINGUISHING SYSTEMS January 1997 PLAN SUBMITTAL REQUIREMENTS FOR SPRAY BOOTHS AND SPRAYING ROOMS EXTINGUISHING SYSTEMS 1.0 PERMIT 1.1 After receipt of a Building Permit from the City of San Jose Building Department, submit

More information

Maintaining Fire Protection Systems

Maintaining Fire Protection Systems Maintaining Fire Protection Systems Fire continues to be a major threat to your business and your personal safety. Each year several thousand people are injured or killed by fires and billions of dollars

More information

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description Worldwide Contacts www.tyco-fire.com Model F thru F3 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description The Mulsifyre Nozzles are open (nonautomatic) nozzles and they are designed

More information

Depending on your facility and the equipment contained within, all or part of the checklists/logs can be printed for use.

Depending on your facility and the equipment contained within, all or part of the checklists/logs can be printed for use. Large Facility Fire Safety Checklists and Logs This package contains checklists to ensure that all fire and life safety equipment are properly inspected. There are also logs on which to record the inspections

More information

PBX Series Quick Fit Connector Bimetallic Steam Traps

PBX Series Quick Fit Connector Bimetallic Steam Traps 6262100/6 IM-P626-01 ST Issue 6 PBX Series Quick Fit Connector Bimetallic Steam Traps Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Commissioning

More information

FLAMMABLE AND COMBUSTIBLE LIQUIDS

FLAMMABLE AND COMBUSTIBLE LIQUIDS GAP.8.1.0 A Publication of Global Asset Protection Services LLC FLAMMABLE AND COMBUSTIBLE LIQUIDS INTRODUCTION National Fire Protection Association (NFPA) documents describe a level of fire protection

More information

Spray Booth Guideline

Spray Booth Guideline Department of Development Service 135 North D Street, Perris CA. 92570 Phone: (951) 443-1029 Fax: (951) 943-3293 PURPOSE The intent of this guideline is to provide the information necessary to ensure that

More information

ESFR "PRE-PRIMED SINGLE INTERLOCKED PREACTION" COLD STORAGE SYSTEM MANUAL

ESFR PRE-PRIMED SINGLE INTERLOCKED PREACTION COLD STORAGE SYSTEM MANUAL ESFR "PRE-PRIMED SINGLE INTERLOCKED PREACTION" COLD STORAGE SYSTEM MANUAL The Viking Corporation 210 N Industrial Park Road Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax:

More information

2010 Residential Water Heater Replacement Check List

2010 Residential Water Heater Replacement Check List 2010 Residential Water Heater Replacement Check List The intent of this check list is to provide installers a general reference for the enforcement of code requirements in the Greater San Diego Area. This

More information

FPS4 APPENDIX A (INTERIM) SPECIFICATION FOR THE INSPECTION AND TESTING OF AUTOMATIC FIRE SPRINKLER SYSTEMS

FPS4 APPENDIX A (INTERIM) SPECIFICATION FOR THE INSPECTION AND TESTING OF AUTOMATIC FIRE SPRINKLER SYSTEMS FPS4 APPENDIX A (INTERIM) SPECIFICATION FOR THE INSPECTION AND TESTING OF AUTOMATIC FIRE SPRINKLER SYSTEMS To be used in conjunction with the Fire Protection Association Australia FPS4-2000: Agreement

More information

Vehicle Fire Protection. An Ownerʼs Manual for ANSUL Fire Suppression/Detection Systems

Vehicle Fire Protection. An Ownerʼs Manual for ANSUL Fire Suppression/Detection Systems Vehicle Fire Protection An Ownerʼs Manual for ANSUL Fire Suppression/Detection Systems 002792 Off-road vehicles do have fires Statistics show that off-road vehicles burn with alarming frequency. These

More information

esfr pendent sprinkler vk510 (k25.2)

esfr pendent sprinkler vk510 (k25.2) January 17, 2014 Sprinkler 124a 1. DESCRIPTION Viking Early Suppression Fast Response (ESFR) Pendent Sprinkler VK510 incorporates the capability to suppress specific high-challenge fires. The addition

More information

ENGINEERING SPECIFICATIONS FOR CO2 EXTINGUISHING AGENT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS

ENGINEERING SPECIFICATIONS FOR CO2 EXTINGUISHING AGENT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS ENGINEERING SPECIFICATIONS FOR CO2 EXTINGUISHING AGENT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS SECTION 1 GENERAL SPECIFICATIONS I. SCOPE This specification outlines the requirements for a pre-engineered

More information

Section 20 TABLE OF CONTENTS Pressurized Equipment and Systems. 20.A General... 20-1. 20.B Compressed Air and Gas Systems... 20-4

Section 20 TABLE OF CONTENTS Pressurized Equipment and Systems. 20.A General... 20-1. 20.B Compressed Air and Gas Systems... 20-4 Section 20 TABLE OF CONTENTS Pressurized Equipment and Systems Section: Page 20.A General... 20-1 20.B Compressed Air and Gas Systems... 20-4 20.C Boilers and Systems... 20-7 20.D Compressed Gas Cylinders...

More information

Technical Requirements for Aboveground Storage Tanks (ASTs) Storing Class IIIB Liquids (other than used oil)

Technical Requirements for Aboveground Storage Tanks (ASTs) Storing Class IIIB Liquids (other than used oil) Technical Requirements for Aboveground Storage Tanks (ASTs) Storing Class IIIB Liquids (other than used oil) References: Comm 10 2009 EDITION / NFPA 30 2008 EDITION ITEM DESCRIPTION Comm 10 / NFPA General

More information

TECHNICAL DATA. Dry 122a. November 12, 2013

TECHNICAL DATA. Dry 122a. November 12, 2013 Dry 122a 1. PRODUCT DESCRIPTION The Viking is a quick-opening device. When installed with the required external Anti-flood Device, the assembly is designed to increase the operating speed of Viking Model

More information

ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR 1910.252 WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600

ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR 1910.252 WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600 OSHA REGULATION: 9 CFR 90.5 WELDING, CUTTING, AND BRAZING ( HOT WORK ) A. POLICY. This procedure follows requirements set forth in 9 CFR 90.5.. This policy applies to all Hot Work operations being done

More information

Flammable and Combustible Liquids. Slide 1 (of 23)

Flammable and Combustible Liquids. Slide 1 (of 23) Flammable and Combustible Liquids Slide 1 (of 23) Introduction The two primary hazards associated with flammable and combustible liquids are explosion and fire Safe handling and storage of flammable liquids

More information

EXETER TOWNSHIP DRY OR WET CHEMICAL FIRE SUPPRESSION SYSTEMS

EXETER TOWNSHIP DRY OR WET CHEMICAL FIRE SUPPRESSION SYSTEMS DRY OR WET CHEMICAL FIRE SUPPRESSION SYSTEMS POLICY STATEMENT This policy applies to NEW Dry or Wet chemical fire suppression systems. The Authority Having Jurisdiction will not waive major criteria in

More information

OSHA Office of Training and Education 1

OSHA Office of Training and Education 1 Flammable and Combustible Liquids OSHA Office of Training and Education 1 Introduction The two primary hazards associated with flammable and combustible liquids are explosion and fire Safe handling and

More information

A Code Review for Emergency Generators and Indoor Use of Portable Generators

A Code Review for Emergency Generators and Indoor Use of Portable Generators A Code Review for Emergency Generators and Indoor Use of Portable Generators By: the Fire and Life-Safety Group (FLS) Fire Code requires that emergency generators be stationary generators. Therefore, a

More information

OPERATIONS & MAINTENANCE (O&M) FOR PROPANE STORAGE FACILITIES

OPERATIONS & MAINTENANCE (O&M) FOR PROPANE STORAGE FACILITIES OPERATIONS & MAINTENANCE (O&M) FOR PROPANE STORAGE FACILITIES Reference: National Fire Protection Association (NFPA) Pamphlet No. 58 Liquefied Petroleum Gas Code, 2001, Chapter 11 Type of Facility: Petroleum

More information

Requirements for Hydrogen Storage and Use

Requirements for Hydrogen Storage and Use Requirements for Hydrogen Storage and Use I. INTRODUCTION Fire and Life-Safety Group (FLS) The following is a summary of the fire and building code requirements for the storage and use of hydrogen. These

More information

Pressure Vessels (Air Compressors) and LPG Tanks

Pressure Vessels (Air Compressors) and LPG Tanks Pressure Vessels (Air Compressors) and LPG Tanks 1. Identification of Workplace Hazard Any container, tank or vessel that contains pressurized material is a potential hazard to employees due to the force

More information

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2

More information

CONSTRUCTION FIRE SAFETY PLANNING GUIDELINES

CONSTRUCTION FIRE SAFETY PLANNING GUIDELINES CONSTRUCTION FIRE SAFETY PLANNING GUIDELINES Review the following information pertaining to Construction Fire Safety Planning: B.C. Building Code Sections 8.1 up to and including Subsection 8.2.3 B.C.

More information

Name Of Occupancy Date. Yes No Describe

Name Of Occupancy Date. Yes No Describe FIRE PREVENTION INSPECTION CHECKLIST For Class A Occupancy (For Assembly Buildings, Bars, Restaurants, Gyms, Churches, Arenas, Theatres or wherever people gather) Name Of Occupancy Date Physical Address

More information

INSTRUCTIONS FOR BUILDINGS WITH FIRE PROTECTION EQUIPMENT

INSTRUCTIONS FOR BUILDINGS WITH FIRE PROTECTION EQUIPMENT INSTRUCTIONS FOR BUILDINGS WITH FIRE PROTECTION EQUIPMENT FIRE EXTINGUISHERS,SPRINKLER SYSTEMS AND FIRE ALARMS Attachment #1 Inspection of Fire Extinguishers Fire Extinguishers must be tested according

More information

Features. Model EX Low Pressure Dry Pipe Valve System 2 (DN50), 2½ (DN65), 3 (DN80), 76 mm, 4 (DN100 ), 6 (DN150), 165 mm & 8 (DN200)

Features. Model EX Low Pressure Dry Pipe Valve System 2 (DN50), 2½ (DN65), 3 (DN80), 76 mm, 4 (DN100 ), 6 (DN150), 165 mm & 8 (DN200) Features 1. Differential latching clapper-type, lightweight, dependable construction. 2. Low Air Pressurized System, psi -to- 2 psi (0.6 bar -to- 1.9 bar) Max 3. Reset externally. Cover removal is not

More information

FUEL-OIL PIPING AND STORAGE

FUEL-OIL PIPING AND STORAGE CHAPTER 13 FUEL-OIL PIPING AND STORAGE SECTION MC 1301 GENERAL 1301.1 Scope. This chapter shall govern the design, installation, construction and repair of fuel-oil storage and piping systems. The storage

More information

HOT WORK PERMIT PROCEDURES

HOT WORK PERMIT PROCEDURES COLUMBIA UNIVERSITY ENVIRONMENTAL HEALTH & SAFETY HOT WORK PERMIT PROCEDURES COLUMBIA UNIVERSITY MEDICAL CENTER February 2010 1 TABLE OF CONTENTS A. PURPOSE 3 B. SCOPE 3 C. POLICIES AND PROCEDURES 3-4

More information

ADMINISTRATIVE SERVICES MANUAL

ADMINISTRATIVE SERVICES MANUAL Purpose Responsibilities Proper Storage and use of flammable liquids can significantly reduce the possibility of accidental fires and injuries. To minimize risk to life and properly, the requirements of

More information

Fire Safety Plan (Single-Stage Fire Alarm System) (Small Establishment):

Fire Safety Plan (Single-Stage Fire Alarm System) (Small Establishment): Fire Safety Plan (Single-Stage Fire Alarm System) (Small Establishment): Fire Safety Plan Single-Stage Fire Alarm System for: (Business Name) (Business Address) Submission Date - Submitted by - Signature

More information

EXHIBIT A SCOPE OF WORK

EXHIBIT A SCOPE OF WORK EXHIBIT A SCOPE OF WORK 1. (Contractor) shall provide fire alarm system maintenance/repair/testing services as described herein to the California Department of Veterans Affairs (hereinafter CDVA, CalVet,

More information

Sample Written Program. For. Flammable Liquids

Sample Written Program. For. Flammable Liquids Sample Written Program For Flammable Liquids 1 Flammable Liquids. (YOUR COMPANY NAME) Purpose Proper Storage and use of flammable liquids can significantly reduce the possibility of accidental fires and

More information

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459 SECTION 15459 PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division-1 Specification sections, apply to work

More information

NITROUS TRANSFER PUMP INSTRUCTIONS

NITROUS TRANSFER PUMP INSTRUCTIONS NITROUS TRANSFER PUMP INSTRUCTIONS SAFETY TIPS Never directly inhale nitrous oxide. When inhaled in large quantities, nitrous oxide can cause respiratory ailments or in extreme cases, death by suffocation.

More information

Model SW-20 and SW-24 11.2 K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response) General Description

Model SW-20 and SW-24 11.2 K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response) General Description Worldwide Contacts www.tyco-fire.com Model SW-20 and SW-24 11.2 K-factor Extended Ordinary Hazard Horizontal Sidewall s (Standard ) General Description 11.2 K-factor, Extended Ordinary s, Standard are

More information

Factory owners must ensure the boiler is:

Factory owners must ensure the boiler is: Factory owners must ensure the boiler is: * Registered with the Boilers and Pressure Vessels Division, Labour Department * Examined by an appointed examiner and has a valid certificate of fitness * Supervised

More information

ENGINE COOLING SYSTEM

ENGINE COOLING SYSTEM ENGINE COOLING SYSTEM 1988 Toyota Celica 1987-88 TOYOTA Engine Cooling Systems Celica DESCRIPTION The basic liquid cooling system consists of a radiator, water pump, thermostat, cooling fan, pressure cap,

More information

Errata NFPA 1. Fire Code. 2015 Edition

Errata NFPA 1. Fire Code. 2015 Edition Errata NFPA 1 Fire Code 2015 Edition Reference: 2.2, Table 6.1.14.4.1(a) and (b), 13.3.1.6, 13.7.2.13.2.1, 14.11.3.3, 18.5.2, 18.5.3, 20.1.2, 20.1.5.12, 25.1.1, 25.3, 25.4, A.3.3.164.2, and A.13.3.2.9.1

More information

Cost Evaluation of Black Steel Pipe and Galvanized Pipe When Using a Nitrogen Generator

Cost Evaluation of Black Steel Pipe and Galvanized Pipe When Using a Nitrogen Generator Cost Evaluation of Black Steel Pipe and Galvanized Pipe When Using a Nitrogen Generator Andy L. Kaempfer Business Development Manager Potter Electric Signal Company, LLC 1609 Park 370 Place St. Louis,

More information

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS November 2011

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS November 2011 FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS November 2011 COLORADO SPRINGS FIRE DEPARTMENT Division of the Fire Marshal If you have any questions or comments regarding the

More information

Automatic fire-extinguishing systems for commercial cooking

Automatic fire-extinguishing systems for commercial cooking Automatic fire-extinguishing systems for commercial cooking Leading Items First Ignited in Eating and Drinking Establishment Structure Fires, 2000-2004 Annual Averages Cooking materials, incl. food and

More information

Interfacing Elevators with Fire Alarm and Sprinklers

Interfacing Elevators with Fire Alarm and Sprinklers Interfacing Elevators with Fire Alarm and Sprinklers IEEE Atlanta Chapter May 15, 2006 Brian K Fabel, PE Agenda Today s Codes NFPA, ASME, IBC/IFC Conflicts/Issues Tomorrow s Codes? Applicable Codes NFPA

More information

HELIPORT FUEL/WATER SEPARATOR MODEL H-200

HELIPORT FUEL/WATER SEPARATOR MODEL H-200 HELIPORT FUEL/WATER SEPARATOR MODEL H-200 Suite 150 Voice 1-973-540-0011 55 Madison Avenue Fax 1-973-540-0131 Morristown, NJ 07960-6012 Email info@heliport.com U.S.A. Web www.heliport.com A. PRINCIPLE

More information

Fire Safety Plan (Single-Stage Fire Alarm System - Small Establishment)

Fire Safety Plan (Single-Stage Fire Alarm System - Small Establishment) 1 Fire Safety Plan (Single-Stage Fire Alarm System - Small Establishment) Fire Safety Plan Single-Stage Fire Alarm System (small establishment) for: (Business Name) (Business Address) The reproduction

More information

Flammable Liquids 29 CFR 1910.106

Flammable Liquids 29 CFR 1910.106 Flammable Liquids 29 CFR 1910.106 OSHA s Directorate of Training and Education These materials were developed by OSHA s Directorate of Training and Education and are intended to assist employers, workers,

More information

I-768 FireLock NXT Dry Valve

I-768 FireLock NXT Dry Valve HANG THESE INSTRUCTIONS ON THE INSTALLED VALVE FOR EASY FUTURE REFERENCE WARNING WARNING Failure to follow instructions and warnings can cause product failure, resulting in serious personal injury and

More information

AIR LINE VALVES AND GAUGES

AIR LINE VALVES AND GAUGES AIR LINE VALVES AND GAUGES INGERSOLL-RAND AIR LINE VALVES AND GAUGES Maintaining consistent air pressure throughout the entire system is crucial for maximum performance and productivity. Ingersoll-Rand

More information

Wet System. Technical Manual for Operation, Maintenance, and Troubleshooting

Wet System. Technical Manual for Operation, Maintenance, and Troubleshooting Wet System Technical Manual for Operation, Maintenance, and Troubleshooting October, 2008 Form No. F_010508 Page II October 15, 2008 Table of Contents Page I. DESCRIPTION 3 II. APPLICATIONS 4 III. REQUIREMENTS

More information

GUIDELINE 5. CLASSES OF FIRE, TYPES OF PORTABLE FIRE EXTINGUISHERS, INSPECTION & MAINTENANCE OF FIRE EXTINGUISHERS IN UNIVERSITY BUILDINGS

GUIDELINE 5. CLASSES OF FIRE, TYPES OF PORTABLE FIRE EXTINGUISHERS, INSPECTION & MAINTENANCE OF FIRE EXTINGUISHERS IN UNIVERSITY BUILDINGS GUIDELINE 5. CLASSES OF FIRE, TYPES OF PORTABLE FIRE EXTINGUISHERS, INSPECTION & MAINTENANCE OF FIRE EXTINGUISHERS IN UNIVERSITY BUILDINGS 1.0 PURPOSE 1.1 To provide an overview of fire extinguisher use

More information

CARING FOR YOUR WATER HEATER

CARING FOR YOUR WATER HEATER http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html Water Heater Inspections CARING FOR YOUR WATER HEATER Venting System (Direct Vent Only) The venting system should be inspected

More information