Fujitsu General New Zealand Ltd
|
|
- Valerie Daniel
- 8 years ago
- Views:
Transcription
1
2 Fujitsu General New Zealand Ltd
3 Ozone layer protection Global warming prevention HCFC (R22) Ozone depletion potential : Global warming potential : 1, Montreal Protocol adoption Complete abolishment of ozone depletion substances 1980 Alternative 1996 (Advanced countries) Reduction HFC (R410A) Ozone depletion potential 0 Global warming potential 1, Kyoto Protocol Adoption HCFC Total abolition Reduction of greenhouse effect gases 2013 (Developing countries) Reduction New refrigerant Ozone depletion potential : 0 Global warming potential : Lower value HCFC Total abolition
4
5 } R32 has been used in Japan, Indonesia and India for the last 12 months without incident. } In Australia, Gree and Kelvinator currently have 38 R32 models registered. } All other brands are currently investigating the release of these products in Oceania, this includes Daikin, Mitsubishi, Panasonic and LG. } Fujitsu will be one of the first companies to sell these products.
6 EER (Cooling) 7.1kW class EER (Cooling) 2.8kW class R410A R32 0 R410A R32 EER 25% up EER 6% up
7 } Combustion will not occur unless three conditions are met, Refrigerant concentration, constant oxygen, and an ignition source. Refrigerant concentration Area 14 to 30 vol.% (0.3 to 0.6 kg/m 3 ) R32 Constant oxygen Ignition source Minimum Ignition energy 30 to 100 mj (Static electricity : 1.25mJ)
8 How Flammable can R32 be? There is not enough concentration to ignite even if all the refrigerant should leak from 7.1kW class model in an approximately 7m 2 room. 1.8m Refrigerant concentration area 14 to 30 vol.%
9 Even if ignited, the flame propagation speed is slower than the speed of a person walking. 4 km/h R32 R32 combustion speed Approx 1.9 km/h The risk of fire spreading is quite low.
10 } Three items engineers considered for fire prevention Construction that makes refrigerant stagnation minimised Electrical parts have been designed to make ignition difficult non spark components Chassis design makes fire propagation difficult The risk of fire has been reduced.
11
12 Releasing refrigerants into the atmosphere is illegal Refrigerators, freezers and air-conditioning units contain refrigerants that damage the environment. Synthetic greenhouse gases (SGGs) are now widely used as refrigerants in fridges and air-conditioning units. Under the Climate Change Response Act (CCRA) 2002 it is illegal to release SGGs into the atmosphere. (This came into effect on 1 January 2013.) Refrigerants that are ozone-depleting substances are being phased out under the Ozone Layer Protection Act (OLPA) It is illegal to release these refrigerants into the atmosphere. The Environmental Protection Authority has enforcement powers under the CCRA and OLPA. If you release SGGs or ozone-depleting refrigerants into the atmosphere, there are serious penalties. It's important that you know what refrigerants the appliances you work with contain, and that you don't release these into the atmosphere.
13 Approved fillers Anyone filling compressed gas containers with gas must be an approved filler. This requirement applies to all compressed gases, including air. What is an approved filler? An approved filler is someone certified to fill compressed gas containers, such as: 1. industrial gas cylinders 2. liquefied petroleum gas (LPG) cylinders 3. self-contained underwater breathing apparatus (SCUBA) 4. self-contained breathing apparatus (SCBA) 5. fire extinguishers 6. aerosol cylinders 7. paintball cylinders
14 } It is illegal to retrofit or convert a refrigeration or air conditioner appliance with a refrigerant it is not designed for. } Electrical safety regulators advice on converting systems } and equipment is: 1. If equipment has not been confirmed as being designed, manufactured and tested to be compliant to relevant electrical safety standards for use with the proposed refrigerant then conversion of the equipment or use of the proposed refrigerant should not occur. 2. All domestic electrical appliances must be shown to comply with the relevant electrical safety product standard for use with the proposed refrigerant.
15 } Customers to have completed a recognised flammable gas fillers course and be certified. } Attended a Fujitsu R32 Training Course } Completed a test questionnaire and passed. } Prove ownership and use of torque spanner set } Sign the R32 product supply agreement
16 Supply Agreement
17 R32
18
19
20 } When servicing an air conditioner containing a Flammable refrigerant, the service mechanic must set up a temporary flammable zone:
21 } Manufacturers responsibility: } Cartons
22 } Manufacturers responsibility: } Product Warning Label Caution Label Safety/Compliance Label
23 } Installers Responsibility Class Label Piping Label
24
25
26
27 2013 New Line up Image unification by simple design that beautifully harmonizes with the interior NEW KU series NEW KM series 31
28 2013 New Line up Designer range LU series NEW KU series Reverse cycle LV series LF series NEW KM series
29 Features Current Model Cooling 4.0 New Model Cooling 2.5kW Cooling kW
30 Features Capacity class(kbtu) Capacity class(kw) KU Series (Designer range) * ASTG09KUCA ASTG12KUCA ASTG18KUCA KM Series (Reverse Cycle) ASTG09KMCA ASTG12KMCA ASTG18KMCA ASTG22KMCA ASTG24KMCA Blue : Cooling Operation Red : Heating Operation *1 : 14[kBtu] class
31 Features High Density Multi-path Heat Exchanger Large Heat Exchanger 2 rows 20 stages + 1 row 4 stages High Efficiency DC Fan motor High Efficiency Refrigerant DC Rotary Compressor High Efficiency DC Fan Motor
32 Features New Model LF/JF series 320mm 300mm 998mm 940mm Star Rating (Cooling) Star Rating (Cooling)
33 Energy saving operation by detecting movement. Human Sensor
34 Features } The diffuser is automatically adjusted to the ideal angle so that air direction is matched to the operation mode for better circulation Heating (KM series) Cooling
35 Features Easier weekly timer setting (KM series)
36 Others Communication Kit (Option) or or (Accessory) Wired Remote Controller (High grade) (Option) Wired Remote Controller (Option) Hotel Simple Remote Controller (Option) The air conditioner automatically stops when the card key is removed from the door when the customer is leaving the hotel room. Communication kit Off Relay Card key
37 : Released TBA : Released in TBA : Released in TBA Capacity class(kbtu) Capacity class(kw) KU Series (Design model) ASTG09KUCA ASTG12KUCA ASTG18KUCA KM Series (Reverse Cycle) ASTG09KMCA ASTG12KMCA ASTG18KMCA ASTG22KMCA ASTG24KMCA
38 2013 Wall mounted type KU/KM Series For Oceania Installation
39 Contents 1. Product Special Measures 2. Tools to Use for Installation 3. Installation Method and Precautions
40 1.Product Special Measures Copyrights 2013 Fujitsu General Limited, Engineering Support. All rights reserved. 47
41 1. Product Special Measures The products use the R32 refrigerant with lower flammability characteristics, so special measures are required for the products. A flare-less joint is used to prevent refrigerant leaks and comply with safety standards. Electrical component cover design prevents fire from spreading. Pipe cover design prevents fire from spreading.
42 2. Tools to Use for Installation Copyrights 2013 Fujitsu General Limited, Engineering Support. All rights reserved. 49
43 2. Tools to Use for Installation The following R32 tools are same as R410A tools, except the part. Tool Name Note 1 Vacuum pump 2 Refrigerant Recovery 3 Leak detector 4 Cylinder bung 5 Gauge manifold 6 Charge hose 7 Torque wrench 8 Flare tool 9 Pipe cutter 10 Pipe bender 11 Hex wrench 12 Service refrigerant cylinder 13 Refrigerant collection cylinder 14 Flare-less joint nut removal tool Same as R410A tool ( Those that use a series motor,use a carbon brush, cannot be used. ) Same as R410A tool Same as R410A tool Same as R410A tool Same as R410A tool Same as R410A tool Same as R410A tool Same as R410A tool Same as R410A tool Same as R410A tool R32 original container ( Use a cylinder marked with R32 ) R32 original container ( Refrigerants cannot be mixed during collection. R32 original tool
44 3. Installation Method and Precautions Copyrights 2013 Fujitsu General Limited, Engineering Support. All rights reserved. 51
45 3. Installation Method and Precautions New piping connection method Flare-less joint Flare-less joint nut At factory shipment Same as before Flare joint
46 3. Installation Method and Precautions Flare-less joint and Flare-less joint nut removal tool Flare-less joint nut Flare-less joint nut At factory shipment Cannot be reused after being used once. Indoor unit Flare-less joint nut removal tool
47 3. Installation Method and Precautions The following items will be explained. 3-1 Connection method using the flare-less joint nut Step 1 ~ Step Method for removing the flare-less joint nut Step 1 ~ Step 5
48 3. Installation Method and Precautions 3-1 Connection method using a flare-less joint nut STEP 1 Draw a line to check the insertion of the pipe to be connected to the indoor unit. L Outdoor unit side Connection pipe diameter [mm (in.)] L [mm] 6.35(1/4) dia. 20 to (3/8) dia. 21 to (1/2) dia. 25 to 26 STEP 2 Turn the nut in the arrow direction to open the pipe insertion opening. Outdoor unit side Indoor unit side One-half turn
49 3. Installation Method and Precautions 3-1 Connection method using a flare-less joint nut STEP 3 Insert the pipe into the flare-less joint until you can no longer see the line you drew. Tighten loosely by hand Outdoor unit side Indoor unit side STEP 4 Use a torque wrench to apply torque to the flare-less joint nut. Outdoor unit side Same as R410A Tightening nut (hexagon) [mm (in.)] Tightening torque [N m (kgf cm] 6.35(1/4) dia. 16 to (3/8) dia. 32 to (1/2) dia. 49 to 58 Torque wrench Indoor unit side
50 3. Installation Method and Precautions 3-1 Connection method using a flare-less joint nut STEP 5 Check the following 2 points to make sure the pipes are connected firmly. Check 1: Make sure the D gap is 0.5 [mm] or less. D Outdoor unit side Indoor unit side Check 2: Make sure you cannot see the line to confirm how far the pipe is inserted. OK NG There is a possibility refrigerant will leak out.
51 3. Installation Method and Precautions 3-2 Flare-less joint nut removal method STEP 1 Use a torque wrench to remove the outdoor unit side nut. Outdoor unit side Indoor unit side Torque wrench STEP 2 Insert a flathead screwdriver into the plastic cover gap to split the cover. Flathead screwdriver Plastic part gap Outdoor unit side Indoor unit side
52 3. Installation Method and Precautions 3-2 Flare-less joint nut removal method STEP 3 Pass the outdoor unit side pipe through the flare-less joint removal tool. Outdoor unit side Indoor unit side STEP 4 Attach the flare-less joint removal tool to the flare-less joint. Flare-less joint nut removal tool Outdoor unit side Indoor unit side Loosely tighten by hand
53 3. Installation Method and Precautions 3-2 Flare-less joint nut removal method STEP 5 Use a torque wrench to apply torque to removing the flare-less joint removal tool. Outdoor unit side Indoor unit side Flare-less joint nut removal is completed Outdoor unit side Indoor unit side
54 3. Installation Method and Precautions 3-2 Flare-less joint nut removal method STEP 5 Use a torque wrench to apply torque to removing the flare-less joint removal tool. Outdoor unit side Indoor unit side Flare-less joint nut removal is completed Outdoor unit side Indoor unit side
55 3. Installation Method and Precautions 3-2 How to acquire the flare-less joint nut and flare-less joint nut removal tool Before release During installation Repairs 1. Flare-less joint nut - Included with product Option 2. Flare-less joint nut removal tool Provide 12.70(1/2) dia. 9.52(3/8) dia. 6.35(1/4) dia (1/2) dia. 9.52(3/8) dia. 6.35(1/4) dia. 1. Flare-less joint nut 2. Flare-less joint nut removal tool
56 Thank you
R-32. The next generation refrigerant for air conditioners and heat pumps
R-32 The next generation refrigerant for air conditioners and heat pumps Daikin is the first company in the world to launch heat pumps and air conditioners charged with R-32. This refrigerant has several
More informationR-32. The next generation refrigerant for air conditioners and heat pumps. Superior energy efficiency and low GWP
R-32 The next generation refrigerant for air conditioners and heat pumps Superior energy efficiency and low GWP HFC phase-down and the introduction of R32 The European phase-down of HFCs, which will see
More informationSTORE HAZARDOUS SUBSTANCES SAFELY. incompatibles gas cylinders
STORE HAZARDOUS SUBSTANCES SAFELY Suitable containers incompatibles gas cylinders Oxy-Acetylene welding flammable substances 35 36 STORE HAZARDOUS SUBSTANCES SAFELY STORE HAZARDOUS SUBSTANCES SAFELY Storing
More informationSplit-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3A30NA MXZ-4A36NA ATTENTION. English. Français. Español
Split-type Air-Conditioner MXZ-3A30NA MXZ-4A36NA INSTALLATION MANUAL Refer to the installation manual of each indoor unit for indoor unit installation. English Français Español ATTENTION This manual mentions
More information1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan http://www.fujitsu-general.com/
1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan http://www.fujitsu-general.com/ ISO 9001 ISO 14001 Certified number : 01 100 89394 Certified number : 01 104 9245101 Fujitsu General (Thailand) Co.,
More informationDuctless Split Air Conditioner
Ductless Split Air Conditioner Installation Manual Indoor HSU09VHG(DB)-W HSU12VHG(DB)-W HSU18VHH(DB)-W HSU24VHG(DB)-W Outdoor HSU09VHG(DB)-G HSU12VHG(DB)-G HSU18VHH(DB)-G HSU24VHG(DB)-G Table of Contents
More informationThe phase out of R22. Phase out of HCFCs
The phase out of R22 The Montreal Protocol on Substances that Deplete the Ozone Layer is widely regarded as the world s most successful environment protection agreement. It is the only treaty with universal
More informationSYLLABUS FOR SIX MONTHS - FULL TIME CERTIFICATE COURSE IN REFRIGERATION AND AIR-CONDITIONING. Effective From :- UNDER DEVELOPMENT.
SYLLABUS FOR SIX MONTHS - FULL TIME CERTIFICATE COURSE IN REFRIGERATION AND AIR-CONDITIONING Effective From :- UNDER DEVELOPMENT Prepared by: Curriculum development cell Institute of Research Development
More informationHow to choose a heat pump and use it wisely
How to choose a heat pump and use it wisely Contents How does a heat pump work? 2 Insulating your home 3 Heat loss in the home Not all heat pumps are created equal 4 Choosing a heat pump 4 Choosing by
More informationAIR-CONDITIONER SPLIT TYPE
FILE NO. A08-016 SERVICE MANUAL AIR-CONDITIONER SPLIT TYPE RAS-M10PKVP-E, RAS-M13PKVP-E, RAS-M16PKVP-E, RAS-M18PKVP-E / RAS-M10PKVP-ND, RAS-M13PKVP-ND, RAS-M16PKVP-ND, RAS-M18PKVP-ND / RAS-3M26GAV-E1,
More informationLG Floor Standing Type Air Conditioner INSTALLATION MANUAL
website http://www.lgservice.com e-mail http://www.lgeservice.com/techsup.html LG Floor Standing Type Air Conditioner INSTALLATION MANUAL LG IMPORTANT Please read this installation manual completely before
More informationyork air-conditioning products Residential & VRF News 2015
york air-conditioning products Residential & VRF News 2015 york air-conditioning products Catalogue Content Split Systems Pag. High wall High Efficiency Inverter YWHJZH 09 to 24 K 6 High wall Inverter
More informationKSV70HRF. KSV70HRF - 7.1kW Split System Air Conditioner - Reverse Cycle
KSV70HRF RRP AUS $1,709.00 Split System Reverse Cycle air conditioner featuring inverter technology, clean front with LED display, Bio and active carbon filter, 2 way auto swing (up, down), remote (7.1kW
More informationTECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05
TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: AW52AL AW64AL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. AW52AL 387030095 AW64AL 387030096 0.8180.463.0 07/05 IMPORTANT! Please read before installation
More informationDUCTED AIR CONDITIONING SOLUTIONS
DUCTED AIR CONDITIONING SOLUTIONS H I G H E N E R G Y E F F I C I E N C Y B A C K E D B Y A 5 Y E A R F U L L P A R T S & L A B O U R W A R R A N T Y DUCTED RANGE WHY CHOOSE FUJITSU? AUSTRALIA S FAVOURITE
More informationGuide to good leak testing
Page 0 Guide to good leak testing The Institute of Refrigeration, working with the Carbon Trust, brings you REAL Zero Refrigerant Emission and Loss Zero. The aim of this project is in the title zero refrigerant
More informationGlossary of Heating, Ventilation and Air Conditioning Terms
Glossary of Heating, Ventilation and Air Conditioning Terms Air Change: Unlike re-circulated air, this is the total air required to completely replace the air in a room or building. Air Conditioner: Equipment
More informationINSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX
Fan Coil Replacement Coil Kit EBX & EBXX These instructions must be read and understood completely before attempting installation. These instructions covers the installation of replacement coil kit into
More informationAir Conditioner Water Heater - A Product of HotSpot Energy LLC
Air Conditioner Water Heater - A Product of HotSpot Energy LLC PLEASE READ THIS BEFORE YOU INSTALL THE UNIT 1. This air conditioner must be installed and/or repaired by a qualified technician. If you perform
More informationAir conditioning is AIR CONDITIONING GUIDE
ool Air conditioning is AIR CONDITIONING GUIDE ool Contents Making the right decisions for the right reasons Keep a cool head 2 Buying 3 Be a cool customer Installation 5 For a licensed technician, installation
More informationReverse Cycle Inverter Split System Air Conditioner
Reverse Cycle Inverter Split System Air Conditioner Model Number TAC-09CHSA/JAI5 INSTALLATION MANUAL Contents 03 Warranty Details 04 Welcome 05 General Safety Instructions 06 Product Overview 07 Selecting
More informationTest Code: 8297 / Version 1
Blueprint HVAC Maintenance Technology PA Test Code: 8297 / Version 1 Copyright 2014. All Rights Reserved. General Assessment Information HVAC Maintenance Technology PA Blueprint Contents General Assessment
More informationNational Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook
National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook Trainee:... Training Provider:... Year:... Trainee Contact no:... Competency Based Skill Training Logbook Introduction
More informationINSTALLATION MANUAL INSIDE ENGINE COMPARTMENT ZZT22#R (1ZZ-FE / 3ZZ-FE) / AZT220R (1AZ-FE) FOR EUROPEAN SPEC. AIR CONDITIONING ENGLISH.
HFC 134a Ozone Friendly Refrigerant ZZT22#R (1ZZ-FE / 3ZZ-FE) / AZT220R (1AZ-FE) FOR EUROPEAN SPEC. AIR CONDITIONING ENGLISH AAAMU-63 INSIDE ENGINE COMPARTMENT INSTALLATION MANUAL 2000 (EUROPE) B.V.. All
More informationRS-24 (R426A): Q & A
RS-24 (R426A): Q & A 1 Q: What is RS-24? A: RS-24 is a non ozone depleting Drop-in replacement for R12 in all applications including mobile air conditioning. 2 Q: Yes, but what does RS-24 contain? A: RS-24
More informationNext-Generation Refrigerants for Energy Efficiency and Climate Protection. 5 th March 2014 Daikin Air-conditioning India Pvt. Ltd.
Next-Generation Refrigerants for Energy Efficiency and Climate Protection 5 th March 2014 Daikin Air-conditioning India Pvt. Ltd. Daikin Worldwide Daikin Industries Ltd. Turnover: 1.3 Trillion Yen No.
More informationAddendum to Florida Academy Catalog for: HVAC Fundamentals HVAC Advanced Fundamentals
Addendum to Florida Academy Catalog for: HVAC Fundamentals HVAC Advanced Fundamentals HVAC PROGRAMS The school s Heating, Ventilation, and Air Conditioning Programs provide training for entry level employment
More informationSYLLABUS For BASIC TRADE COURSE (360 Hours) On REFRIGERATION AND AIR CONDITIONING
SYLLABUS For BASIC TRADE COURSE (360 Hours) On REFRIGERATION AND AIR CONDITIONING INDEX 1. Introduction 3 2. Objectives 3 3. Employment Opportunity 4 4. Course Structure 4 5. Entry Qualification 4 6. List
More informationHitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE
Hitachi Air Conditioning Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE Contents Page 04 Product Range 08-09 RAC Summit Wall Mounted 10 RAC Shirokuma Wall mounted 11 RAC S Series - Wall
More informationUSER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA
USER S MANUAL FH052EAV1 FH070EAV1 E HNIKA PORTUGUÊS ENGLISH ESPAÑOL ITALIANO DEUTSCH FRANÇAIS System Air Conditioner (Cooling and Heating) E S F I P D G DB98-29263A(1) Safety Precautions Register your
More informationSECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
More informationGENERAL INFORMATION FOR REPAIR AND MAINTENANCE OF CENTRAL AIR CONDITIONING PLANT ( Direct & Chiller ).
GENERAL INFMATION F REPAIR AND MAINTENANCE OF CENTRAL AIR CONDITIONING PLANT ( Direct & Chiller ). Name of sector Refrigeration & Air Conditioning Name of Module REPAIR AND MAINTENANCE OF CENTRAL AIR CONDITIONING
More informationFULL DC INVERTER SYSTEMS
FULL DC INVERTER SYSTEMS INDIDUAL AND MODULAR DESIGN & FLEXIBLE COMBINATION commercial air conditioners SDV4 2011/2012 AIR CONDITIONING 1 WELCOME TO THE WORLD of SINCLAIR AIR CONDITIONERS Company operation
More informationAIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries
AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries Hot tips and cool ideas to save energy and money! Air conditioning units or systems are often used by foundries
More informationRS-44 (R424A) : Q & A
RS-44 (R424A) : Q & A 1 Q: What is RS-44? A: RS-44 is a non ozone depleting Drop-in replacement for R22 in most applications. 2 Q: Yes, but what does RS-44 contain? A: RS-44 is a blend of HFC134a, HFC125,
More informationRefrigeration & Air Conditioning
& Air Conditioning The Fundamentals of Commercial Trainers Air Conditioning Systems Semi-Hermetic Air Compressors Controls Automotive Air Conditioning Chilled Water Air Conditioning Plant More and more
More informationNewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ELECTRICAL SAFETY This appliance is for indoor use only. Always turn off the unit and unplug
More informationHEAVY DUTY STORAGE GAS
Multi-Fin flue technology Flue damper saves energy Electronic controls HEAVY DUTY STORAGE GAS Dependability The Rheem heavy duty gas range is the work horse of the industry having proved itself over many
More informationCleaning Instructions for Burner, Pilot Assembly, and Emitter Screen Series: 220000-450000
Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen Series: 220000-450000 10 mm open end wrench 12 mm open end wrench 9/16 open end wrench 5/8 open end wrench 11/16 open end wrench 9/16
More informationCU-2E15LBE CU-2E18LBE CU-3E18LBE CU-4E23LBE
Order No. PHAAM1003090C3 Outdoor Unit CU-2E15LBE CU-2E18LBE CU-3E18LBE CU-4E23LBE Air Conditioner Please file and use this manual together with the service manual for Model No. CS-E7LKEW CU-E7LKE CS-E7LKEW
More informationTHC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER
THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER Certified to / Certifié à CGA 2.14 M2000 Conforms to / Conforme à ANSI std Z83.7 2000 Suitable for indoor or outdoor installation / Unvented / Unattended Type
More informationUpdate on R32 Air-conditioning and Heat Pump Manufacturing and Sales -Progress Since Last OEWG in Bangkok 2012-
Update on R32 Air-conditioning and Heat Pump Manufacturing and Sales -Progress Since Last OEWG in Bangkok 2012-29.6.2013 Mark Stanga Daikin Industries Ltd. Contents Progress in Japan Progress in India
More informationTechnical Note: Comparing R407C and R410A as Alternatives for R22. A Technical Note from the Experts in Business-Critical Continuity
Technical Note: Comparing R407C and R410A as Alternatives for R22 A Technical Note from the Experts in Business-Critical Continuity Purpose The purpose of this document is to provide a brief overview of
More informationInstallation Manual AIR CONDITIONER (MULTI-SPLIT TYPE) Outdoor Unit RAS-5M34UAV-E1. For OUTDOOR USE only. Model name: English
AIR CONDITIONER (MULTI-SPLIT TYPE) Outdoor Unit For OUTDOOR USE only Model name: RAS-5M34UAV-E1 Outdoor Unit 2 English Manuel du proprietaire Unité hydroélectrique 16 Français Betriebsanleitung Wassergerät
More informationFloor Type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MFZ-KA25VA MFZ-KA35VA MFZ-KA50VA. English
Floor Type Air-Conditioner MFZ-KA25VA MFZ-KA35VA MFZ-KA50VA INSTALLATION MANUAL This manual only describes the installation of indoor unit. When installing the outdoor unit, refer to the installation manual
More informationHFCS, REFRIGERATION AND AIR-CONDITIONING: MINIMISING CLIMATE IMPACT, MAXIMISING SAFETY
HFCS, REFRIGERATION AND AIR-CONDITIONING: MINIMISING CLIMATE IMPACT, MAXIMISING SAFETY HFCS, REFRIGERATION AND AIR-CONDITIONING: MINIMISING CLIMATE IMPACT, MAXIMISING SAFETY The impact of refrigeration
More informationCleaning Instructions for Burner, Pilot Assembly, and Emitter Screen. Series: 150000 200605 LP Gas
Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen Series: 150000 200605 LP Gas Tools needed Bottle brush Non-abrasive scouring pad Small utility brush Heavy-duty pipe cleaners Air hose
More informationWall Mounted Mini Split Heat Pump Air Conditioner
Wall Mounted Mini Split Heat Pump Air Conditioner OPERATING AND INSTALLATION MANUAL Model: KFIHP-09-ID / KFHIP-09-OD KFHHP-12-ID / KFHHP-12-OD Indoor Unit. Outdoor Unit. Thank you for selecting Soleus
More informationHeating, Ventilation, Air Conditioning and Refrigeration (HVACR)
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) I. Demonstrate safety skills in typical HVACR work situations to NATE Core Installer Knowledge Areas for Technician Excellence for Safety
More informationPart A: Fluid properties
UNEP Ozone Secretariat UNEP Ozone Secretariat Background Workshop Material on HFC for management: HFC Workshop, technical 2015 issues Bangkok, 20 and 21 April 2015 FACT SHEET 15 Glossary of terms and technical
More informationorlando OWNER S MANUAL
orlando OWNER S MANUAL 2 Assembling & operating manual Orlando 30 mbar - PORTABLE GAS BARBECUE 1. 2. 3. Improper installation, adjustment, alteration, service or maintenance can injury or property damage.
More informationIt s Your Choice Retrofitting Your Car s A/C System 1EPA. 2 Printed on paper that contains at least 20 percent postconsumer fiber.
United States EPA430-F-97-052 Environmental Protection June 1997 Agency 1EPA Air and Radiation (6205J) It s Your Choice Retrofitting Your Car s A/C System 2 Printed on paper that contains at least 20 percent
More informationINSTALLATION MANUAL UH070CAV1 UH105CAV UH140CAV
INSTALLATION MANUAL UH070CAV1 UH105CAV UH140CAV FRANÇAIS ENGLISH ESPAÑOL System Air Conditioner (Cooling and Heating) E S F DB98-29516A(3) Safety Precautions (Carefully follow the precautions listed below
More informationInstallation manual AIR CONDITIONER (MULTI TYPE) Outdoor Unit. Installation manual. Model name: <Heat Pump Model> <Cooling Only Model>
AIR CONDITIONER (MULTI TYPE) Installation manual Outdoor Unit Model name: MMY-MAP0804HT8-E MMY-MAP1004HT8-E MMY-MAP1204HT8-E MMY-MAP1404HT8-E MMY-MAP1604HT8-E MMY-MAP0804HT8Z-E MMY-MAP1004HT8Z-E
More informationCleaning Instructions, Pilot Replacement and Valve Change. Model No.: 233010 Natural Gas
Cleaning Instructions, Pilot Replacement and Valve Change Model No.: 233010 Natural Gas 8mm open-end wrench 9mm open-end wrench 10mm open-end wrench 12mm open-end wrench 13mm open-end wrench Phillips screw
More informationThe efficient heat pump
The efficient heat pump KCP&L has worked hard to build one of the best reliability records in the industry and we want to help you make the most of the energy we provide. That s why we offer information
More informationNewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS BEFORE USE GENERAL SAFETY INSTRUCTIONS: ALWAYS OPERATE THE UNIT IN AN UPRIGHT POSITION AND PLACE
More informationCLIMATE CHANGE POLICY FRAMEWORK FOR REFRIGERATION AND AIR CONDITIONING SECTOR
European Partnership CLIMATE CHANGE POLICY FRAMEWORK FOR REFRIGERATION AND AIR CONDITIONING SECTOR A proposal by the European Partnership (EPEE) for action in the European Union I. INTRODUCTION Set out
More informationT160 Heating Refrigeration and AC Technician MTCU Code 55500 Program Learning Outcomes
T160 Heating Refrigeration and AC Technician MTCU Code 55500 Program Learning Outcomes Synopsis of the Vocational Learning Outcomes * The graduate has reliably demonstrated the ability to 1. relate effectively
More informationRS-52 (R428A) RS-52: PHYSICAL PROPERTIES RS-52 R502 Molecular weight 107.5 111.6 Temperature glide o C 0.5 0.2 Boiling point (1 atm)
RS-52 (R428A) COMPOSITION % HFC 125 77.5 HFC 143a 20.0 R600a 1.9 R290 0.6 HCFC replacement Temperature glide R22, 502 & interim blends Approximately 0.8 o C Drop-in or long term Both Lubricant MO/AB/POE
More informationMulti System. 16 SEER, Inverter System. 9,000 to 18,000 BTU/Hr. Single Split
Multi System 16 SEER, Inverter System 9,000 to 18,000 BTU/Hr Single Split 4MXW8-A 4TXM6-A March2013 42 Warnings and Cautions Warnings and Cautions. Notice that warnings and cautions appear at appropriate
More informationCOMPRESSOR REPLACEMENT PROCEDURE
R-22 and R-410A COMPRESSOR REPLACEMENT PROCEDURE Bard Manufacturing Company, Inc. Bryan, Ohio 43506 Since 1914...Moving ahead just as planned Manual No.: 2100-003F Supersedes 2100-003E File: Volume I,
More informationAIR CONDITIONER (SPLIT TYPE)
INSTALLATION MANUAL AIR CONDITIONER (SPLIT TYPE) For general public use ENGLISH EN Indoor Unit RAS-07PKVP-E RAS-10PKVP-E RAS-13PKVP-E RAS-16PKVP-E RAS-18PKVP-E RAS-07PKVP-ND RAS-10PKVP-ND RAS-13PKVP-ND
More informationPORTABLE AIR CONDITIONER
VERY IMPORTANT! MODEL: GDC-AC9RW / GDC-AC9RCS GDC-AC9RCW / GDC-AC12RW GDC-AC12RB / GDC-AC12RCB GDC-AC12RCW INSTRUCTIONS FOR USE PORTABLE AIR CONDITIONER Do not install and use your portable air conditioner
More informationInternational Refrigerant Standards and their Influence on the Global HVAC Industry and Refrigerant Replacement
International Refrigerant Standards and their Influence on the Global HVAC Industry and Refrigerant Replacement Tom Watson, P.E. Fellow ASHRAE, Life Member President ASHRAE Issues Choosing a refrigerant
More informationCS-XE9EKE CU-XE9EKE CS-XE12EKE CU-XE12EKE
Order No. MAC0512111C8 Air Conditioner CS-XE9EKE CU-XE9EKE CS-XE12EKE CU-XE12EKE TABLE OF CONTENTS PAGE 1 Safety Precautions----------------------------------------------- 3 2 Specifications -----------------------------------------------------
More informationDIGITAL SCROLL CENTRAL AIR CONDITIONER (OUTDOOR UNIT)
E-II-YDS-100-140-0907 ENGLISH INSTALLATION MANUAL DIGITAL SCROLL CENTRAL AIR CONDITIONER (OUTDOOR UNIT) YDS System, R410A, R407C & R22 / YDMH-C (B/A) 100&140 For correct installation, read this manual
More informationGree Solar Hybrid Hi Wall Inverter Air Conditioner
Gree Solar Hybrid Hi Wall Inverter Air Conditioner Utilize the natural power of the sun to heat or cool your home. Find out more at www.greeonline.com Why Choose a Solar Hybrid Inverter? The new Gree Solar
More informationSASO XXXX:2016. (Including the modifications approved in Saudi Council Board No. XXX/2016) LARGE CAPACITY AIR CONDITIONERS
SASO XXXX:2016 (Including the modifications approved in Saudi Council Board No. XXX/2016) LARGE CAPACITY AIR CONDITIONERS PERFORMANCE REQUIREMENTS AND METHODS OF TESTING 1 LARGE CAPACITY AIR CONDITIONERS
More informationCertification in the safe and efficient use of alternative refrigerants
Certification in the safe and efficient use of alternative refrigerants Dubai, 29th Oct 2014 Marco Buoni VicePresident, AREA Air Conditioning & Refrigeration European contractors Association (www.area-eur.be)
More informationHVAC For Schools How to purchase an HVAC system that meets your school s unique requirements and stays within your budget
A PRIMER Educational HVAC For Schools How to purchase an HVAC system that meets your school s unique requirements and stays within your budget Contents: Introduction: The best HVAC system is durable, reliable
More informationAir Conditioner CONTENTS CS-TE9DKE CU-TE9DKE CS-TE12DKE CU-TE12DKE. Order No. RAC0502005C2
Order No. RAC0502005C2 Air Conditioner CS-TE9DKE CU-TE9DKE CS-TE12DKE CU-TE12DKE CONTENTS Page Page 1 Features 2 2 Functions 3 2.1. Remote Control 3 2.2. Indoor Unit 4 2.3. Outdoor unit 5 3 Product Specifications
More informationElements Elements describe the essential outcomes.
AURETU005 Application Competency Field Unit Sector Elements Elements describe the essential outcomes. Retrofit and modify air conditioning and HVAC systems This unit describes the performance outcomes
More informationInverter Air Conditioning for Light Commercial Use
Inverter Air Conditioning for Light Commercial Use 02 Cost Saving Comfort An efficient use of time 03 SDISuper Digital Inverter Very efficient energy consumption Keeps down operating costs Heater operation
More informationHVAC Technologies for Building Energy Efficiency Improvements 2013 National Symposium on Market Transformation. Richard Lord Carrier Fellow
HVAC Technologies for Building Energy Efficiency Improvements 2013 National Symposium on Market Transformation Richard Lord Carrier Fellow HVAC Industry Challenges and Issues Ozone Deletion Global Warming
More informationYour safety and the safety of others are very important.
NATURAL GAS TO PROPANE CONVERSION KIT 090 INSTALLATION INSTRUCTIONS FOR ALTITUDES 0 -,00 FT. ONLY PROPANE CONVERSION KIT SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... LP Gas Requirements...
More informationMaterial Safety Data Sheet
1 IDENTIFICATION OF THE SUBSTANCE AND COMPANY a) SUBSTANCE: Natural Gas b) COMPANY: Bord Gáis Éireann PO Box 51 Gasworks Road Cork Telephone: (021) 453 4000 Emergency Telephone: 1850 20 50 50 2 COMPOSITION/INFORMATION
More informationSan josé OWNER S MANUAL
San josé OWNER S MANUAL Assembling & operating manual San josé 30 mbar - PORTABLE GAS BARBECUE 1. 2. 3. Improper installation, adjustment, alteration, service or maintenance can injury or property damage.
More informationUSER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting
More informationCooling system components, removing and installing
Engine BHW Cooling system components, removing and installing Page 1 / 24 19-1 Cooling system components, removing and installing Warning! When doing any repair work, especially in the engine compartment,
More informationEU F-Gas Regulation Guidance Information Sheet 5: Stationary Air-conditioning and Heat Pumps
Information Sheet 5: Stationary Air-conditioning and Heat Pumps Target audience for this Information Sheet This Information Sheet is aimed at organisations that are operators (usually the owner) of stationary
More information1. BEFORE INSTALLATION
ENGLISH SPLIT-TYPE AIR CONDITIONERS INSTALLATION MANUAL JG79A191H03 MSZ-GE06/09/12/15/18NA MSY-GE09/12/15/18NA When installing multi units, refer to the installation manual of the multi unit for outdoor
More information9ASNA-A1-1202 SERVICE MANUAL SENVILLE AIRCONDITIONER DC INVERTER SPLIT WALL-MOUNTED TYPE
9ASNA-A1-1202 SERVICE MANUAL SENVILLE AIRCONDITIONER DC INVERTER SPLIT WALL-MOUNTED TYPE CONTENTS 1. Precaution... 1 1.1 Safety Precaution... 1 1.2 Warning... 1 2. Function... 6 3. Dimension... 9 3.1 Indoor
More informationAIR-CONDITIONER SERVICE MANUAL SPLIT TYPE R410A RAV-SM566KRT-E, RAV-SM806KRT-E RAV-SM566KRT-TR, RAV-SM806KRT-TR INDOOR UNIT.
FILE. SVM-2004 SERVICE MANUAL AIR-CONDITIONER INDOOR UNIT SPLIT TYPE High Wall Type RAV-SM566KRT-E, RAV-SM806KRT-E RAV-SM566KRT-TR, RAV-SM806KRT-TR R40A FILE. SVM-2004 Adoption of New Refrigerant This
More informationEnglish DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL. Français. R410A Split Series. Español MODELS FTXS15LVJU FTXS18LVJU FTXS24LVJU
English DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL R410A Split Series Español Français MODELS FTXS15LVJU FTXS18LVJU FTXS24LVJU Safety Precautions Read these Safety Precautions carefully to ensure
More informationLUCCI AIRFUSION QUEST II CEILING FAN
LUCCI AIRFUSION QUEST II CEILING FAN WITH IR REMOTE INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION. V1.0 QUEST II IR
More informationINSTALLATION MANUAL. R410A Split Series. Models RKS50G2V1B. Installation manual R410A Split series. Installationsanleitung Split-Baureihe R410A
INSTALLATION MANUAL R410A Split Series Installation manual R410A Split series English Installationsanleitung Split-Baureihe R410A Deutsch Manuel d installation Série split R410A Français Models RXS50G2V1B
More informationCU-S9KKQ CU-S12KKQ CU-S18KKQ CU-S24KKQ CS-S9KKQ CS-S12KKQ CS-S18KKQ CS-S24KKQ WARNING
Order No: PHAAM1001037C3 Indoor Unit CS-S9KKQ CS-S12KKQ CS-S18KKQ CS-S24KKQ Outdoor Unit CU-S9KKQ CU-S12KKQ CU-S18KKQ CU-S24KKQ WARNING This service information is designed for experienced repair technicians
More informationSERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit
SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASYG07LECA ASYG09LECA ASYG12LECA ASYG14LECA AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC R410A CONTENTS
More informationPioneer in sustainability
Pioneer in sustainability Over 100 years ago Carrier helped pioneer a new industry, and in the last two decades we have pioneered environmentally sensitive products with a reduced impact on the environment.
More informationPCRNZ0710H. the. ultimate. heat pump air conditioning guide
PCRNZ0710H the ultimate heat pump air conditioning guide Whether you know little or nothing about heat pump air conditioning, or you know quite a lot, you ll find this guide helpful. It provides easy-to-understand
More informationRefrigeration and Air Conditioning with Reduced Environmental Impact
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2000 Refrigeration and Air Conditioning with Reduced Environmental Impact D.
More informationINNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE
INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient
More informationHi Wall Split Air Conditioners
R22 220-240V ~, 50Hz Hi Wall Split Air Conditioners 53KHET 12-18-24 Cool Only 53QHET 12-18-24 Heat Pump INSTALLATION MANUAL Carrier is committed to continuously improving its products according to national
More informationLG Electronics AE Company, Commercial Air Conditioning
www.lgeaircon.com New concept Ecofriendly Highefficiency Heating solution Total heating & Hot water Solution for MULTI V LG Electronics AE Company, Commercial Air Conditioning 2 Yeouidodong, Yeongdeungpogu,
More informationINSTALLATION MANUAL. R410A Split Series. Models. Installation manual R410A Split series. Installationsanleitung Split-Baureihe R410A
INSTALLATION MANUAL R410A Split Series Installation manual R410A Split series English Installationsanleitung Split-Baureihe R410A Deutsch Manuel d installation Série split R410A Français Montagehandleiding
More informationAIR CONDITIONER OUTDOOR UNIT
AIR CONDITIONER OUTDOOR UNIT INSTALLATION MANUAL For authorized personnel only. MANUEL D'INSTALLATION Pour le personnel agréé uniquement. English Français MANUAL DE INSTALACIÓN Solo para personal autorizado.
More informationPropane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL
Propane Conversion Kit Supersedes: 145.25-IOM2 (708) Form 145.25-IOM2 (908) PROPANE CONVERSION KIT INSTALLATION MANUAL "LPKIT " - PROPANE CONVERSION KIT Kits are available for field conversion from natural
More informationUnico Inverter. Unique and efficient.
Unico Inverter. Unique and efficient. INTERNATIONAL PATENT PENDING The first fixed air conditioner without outdoor unit featuring DC Inverter technology. Great performance, reduced consumption. Designed
More informationGuidance for Stationary Refrigeration & Air- Conditioning
Department for Environment, Food and Rural Affairs Guidance for Stationary Refrigeration & Air- Conditioning Guidance: F Gas and Ozone Regulations Information Sheet RAC 5: Qualifications & Certificates
More information