Thread length (overall length)
|
|
|
- Edwin Hicks
- 9 years ago
- Views:
Transcription
1 Cylindrical Proximity Sensor E2A Safe Mounting with Greater Sensing Distance Ensures a sensing distance approximately 1. to 2 times larger than that of any conventional OMRON Sensor. Problems such as the collision of workpieces are eliminated. Full range of standard sizes (M8, M12, M18 and M; both long and short barrels) Modular construction simplifies customization. Ordering Information Size Sensing distance Connection Body material Thread length (overall length) Output configuration Operation mode NO Operation mode NC M8 Shielded 2. mm Pre-wired Stainless 27 () PNP E2A-S8KS2-WP-B1 2M E2A-S8KS2-WP-B2 2M steel NPN E2A-S8KS2-WP-C1 2M E2A-S8KS2-WP-C2 2M 9 (62) PNP E2A-S8LS2-WP-B1 2M E2A-S8LS2-WP-B2 2M NPN E2A-S8LS2-WP-C1 2M E2A-S8LS2-WP-C2 2M M12 connector Stainless 27 () PNP E2A-S8KS2-M1-B1 E2A-S8KS2-M1-B2 steel NPN E2A-S8KS2-M1-C1 E2A-S8KS2-M1-C2 9 (6) PNP E2A-S8LS2-M1-B1 E2A-S8LS2-M1-B2 NPN E2A-S8LS2-M1-C1 E2A-S8LS2-M1-C2 Brass 27 () PNP E2A-M8KS2-M1-B1 E2A-M8KS2-M1-B2 NPN E2A-M8KS2-M1-C1 E2A-M8KS2-M1-C2 9 (6) PNP E2A-M8LS2-M1-B1 E2A-M8LS2-M1-B2 NPN E2A-M8LS2-M1-C1 E2A-M8LS2-M1-C2 M8 connector (- Stainless 27 (9) PNP E2A-S8KS2-M-B1 E2A-S8KS2-M-B2 pin) steel NPN E2A-S8KS2-M-C1 E2A-S8KS2-M-C2 9 (61) PNP E2A-S8LS2-M-B1 E2A-S8LS2-M-B2 NPN E2A-S8LS2-M-C1 E2A-S8LS2-M-C2 Non-shielded. mm Pre-wired Stainless 27 () PNP E2A-S8KN-WP-B1 2M E2A-S8KN-WP-B2 2M steel NPN E2A-S8KN-WP-C1 2M E2A-S8KN-WP-C2 2M 9 (62) PNP E2A-S8LN-WP-B1 2M E2A-S8LN-WP-B2 2M NPN E2A-S8LN-WP-C1 2M E2A-S8LN-WP-C2 2M M12 connector Stainless 27 () PNP E2A-S8KN-M1-B1 E2A-S8KN-M1-B2 steel NPN E2A-S8KN-M1-C1 E2A-S8KN-M1-C2 9 (6) PNP E2A-S8LN-M1-B1 E2A-S8LN-M1-B2 NPN E2A-S8LN-M1-C1 E2A-S8LN-M1-C2 Brass 27 () PNP E2A-M8KN-M1-B1 E2A-M8KN-M1-B2 NPN E2A-M8KN-M1-C1 E2A-M8KN-M1-C2 9 (6) PNP E2A-M8LN-M1-B1 E2A-M8LN-M1-B2 NPN E2A-M8LN-M1-C1 E2A-M8LN-M1-C2 M8 connector (- Stainless 27 (9) PNP E2A-S8KN-M-B1 E2A-S8KN-M-B2 pin) steel NPN E2A-S8KN-M-C1 E2A-S8KN-M-C2 9 (61) PNP E2A-S8LN-M-B1 E2A-S8LN-M-B2 NPN E2A-S8LN-M-C1 E2A-S8LN-M-C2 E2A Cylindrical Proximity Sensor 1
2 Size Sensing distance Connection Body material Thread length (overall length) M12 Shielded. mm Pre-wired Brass () PNP E2A-M12KS-WP-B1 2M E2A-M12KS-WP-B2 2M NPN E2A-M12KS-WP-C1 2M E2A-M12KS-WP-C2 2M 6 (72) PNP E2A-M12LS-WP-B1 2M E2A-M12LS-WP-B2 2M NPN E2A-M12LS-WP-C1 2M E2A-M12LS-WP-C2 2M M12 connector Brass (8) PNP E2A-M12KS-M1-B1 E2A-M12KS-M1-B2 NPN E2A-M12KS-M1-C1 E2A-M12KS-M1-C2 6 (7) PNP E2A-M12LS-M1-B1 E2A-M12LS-M1-B2 NPN E2A-M12LS-M1-C1 E2A-M12LS-M1-C2 Non-shielded 8. mm Pre-wired Brass () PNP E2A-M12KN8-WP-B1 2M E2A-M12KN8-WP-B2 2M NPN E2A-M12KN8-WP-C1 2M E2A-M12KN8-WP-C2 2M 6 (72) PNP E2A-M12LN8-WP-B1 2M E2A-M12LN8-WP-B2 2M NPN E2A-M12LN8-WP-C1 2M E2A-M12LN8-WP-C2 2M M12 connector Brass (8) PNP E2A-M12KN8-M1-B1 E2A-M12KN8-M1-B2 NPN E2A-M12KN8-M1-C1 E2A-M12KN8-M1-C2 6 (7) PNP E2A-M12LN8-M1-B1 E2A-M12LN8-M1-B2 NPN E2A-M12LN8-M1-C1 E2A-M12LN8-M1-C2 M18 Shielded 8. mm Pre-wired Brass 9 (9) PNP E2A-M18KS8-WP-B1 2M E2A-M18KS8-WP-B2 2M NPN E2A-M18KS8-WP-C1 2M E2A-M18KS8-WP-C2 2M 61 (81) PNP E2A-M18LS8-WP-B1 2M E2A-M18LS8-WP-B2 2M NPN E2A-M18LS8-WP-C1 2M E2A-M18LS8-WP-C2 2M M12 connector Brass 9 () PNP E2A-M18KS8-M1-B1 E2A-M18KS8-M1-B2 NPN E2A-M18KS8-M1-C1 E2A-M18KS8-M1-C2 61 (7) PNP E2A-M18LS8-M1-B1 E2A-M18LS8-M1-B2 NPN E2A-M18LS8-M1-C1 E2A-M18LS8-M1-C2 Non-shielded 16. mm Pre-wired Brass 9 (9) PNP E2A-M18KN16-WP-B1 2M E2A-M18KN16-WP-B2 2M NPN E2A-M18KN16-WP-C1 2M E2A-M18KN16-WP-C2 2M 61 (81) PNP E2A-M18LN16-WP-B1 2M E2A-M18LN16-WP-B2 2M NPN E2A-M18LN16-WP-C1 2M E2A-M18LN16-WP-C2 2M M12 connector Brass 9 () PNP E2A-M18KN16-M1-B1 E2A-M18KN16-M1-B2 NPN E2A-M18KN16-M1-C1 E2A-M18KN16-M1-C2 61 (7) PNP E2A-M18LN16-M1-B1 E2A-M18LN16-M1-B2 NPN E2A-M18LN16-M1-C1 E2A-M18LN16-M1-C2 M Shielded 1. mm Pre-wired Brass (6) PNP E2A-MKS1-WP-B1 2M E2A-MKS1-WP-B2 2M NPN E2A-MKS1-WP-C1 2M E2A-MKS1-WP-C2 2M 66 (86) PNP E2A-MLS1-WP-B1 2M E2A-MLS1-WP-B2 2M NPN E2A-MLS1-WP-C1 2M E2A-MLS1-WP-C2 2M M12 connector Brass (8) PNP E2A-MKS1-M1-B1 E2A-MKS1-M1-B2 Non-shielded 2. mm Pre-wired Brass (6) (See note.) NPN E2A-MKS1-M1-C1 E2A-MKS1-M1-C2 66 (8) PNP E2A-MLS1-M1-B1 E2A-MLS1-M1-B2 NPN E2A-MLS1-M1-C1 E2A-MLS1-M1-C2 PNP E2A-MKN2-WP-B1 2M E2A-MKN2-WP-B2 2M NPN E2A-MKN2-WP-C1 2M E2A-MKN2-WP-C2 2M. mm 66 (86) PNP E2A-MLN-WP-B1 2M E2A-MLN-WP-B2 2M 2. mm M12 connector Brass (8) (See note.) Output configuration Operation mode NO Operation mode NC NPN E2A-MLN-WP-C1 2M E2A-MLN-WP-C2 2M PNP E2A-MKN2-M1-B1 E2A-MKN2-M1-B2 NPN E2A-MKN2-M1-C1 E2A-MKN2-M1-C2. mm 66 (8) PNP E2A-MLN-M1-B1 E2A-MLN-M1-B2 NPN E2A-MLN-M1-C1 E2A-MLN-M1-C2 Note: M non-shielded Models with double sensing distance and short barrels cannot be mounted due to the necessary separation distance from the surrounding metal. Standard sensing models are thus available. 2 E2A Cylindrical Proximity Sensor
3 Model Number Legend Example: E2A-M12LS-M1-B1 Standard, M12, long barrel, shielded, Sn= mm, M12 connector, PNP-NO E2A-M8KN-WP-B1 M Standard, M8, short barrel, non-shielded, Sn= mm, pre-wired PVC cable, PNP-NO, cable length= m 1. Basic name 8. Kind of connection E2A WP: Pre-wired, PVC 2. Sensing technology M1: M12 connector (-pole) Blank: Standard double distance M: M8 connector (-pole). Housing shape and material M: M8 connector (-pole) M: Cylindrical, metric threaded, brass 9. Power source and output S: Cylindrical, metric threaded, stainless steel B: DC, -wire, PNP open collector. Housing size C: DC, -wire, NPN open collector 8: 8 mm D: DC, 2-wire 12: 12 mm E: DC, -wire, NPN voltage output 18: 18 mm F: DC, -wire, PNP voltage output : mm.operation mode. Barrel length 1: Normally open (NO) K: Standard length 2: Normally closed (NC) L: Long body 11.Specials (e.g., cable material, oscillating frequency) 6. Shield S: Shielded 12.Cable length N: Non-shielded Blank: Connector type 7. Sensing distance Numeral: Cable type Numeral: Sensing distance: e.g. 2=2 mm, 16=16 mm E2A Cylindrical Proximity Sensor
4 Specifications DC -wire Models Item Size M8 M12 Type Shielded Non-shielded Shielded Non-shielded Sensing distance 2 mm ± % mm ± % mm ± % 8 mm ± % Setting distance to 1.6 mm to.2 mm to.2 mm to 6. mm Differential travel Target % max. of sensing distance Ferrous metal (The sensing distance decreases with non-ferrous metal.) Standard target (mild steel ST7) mm mm mm mm Response frequency 1, Hz 1, Hz 1, Hz 8 Hz Power supply voltage (operating voltage range) Current consumption (DC -wire) Output type Control output Indicator Load current (See note 2.) 12 to 2 VDC. Ripple (p-p): % max. ( to 2 VDC) ma max. -B models: PNP open collector -C models: NPN open collector 2 ma max. (2 VDC max.) Residual voltage 2 V max. (under load current of 2 ma with cable length of 2 m) Operation indicator (Yellow LED) Operation mode (with sensing object approaching) Protection circuit -B1/-C1 models: NO -B2/-C2 models: NC For details, refer to the timing charts. Power source circuit reverse polarity protection, Surge suppressor, Short-circuit protection Output reverse polarity protection, Power source circuit reverse polarity protection, Surge suppressor, Short-circuit protection Ambient air temperature Operating: C to 7 C, Storage: C to 8 C (with no icing or condensation) Temperature influence (See note 2.) ±% max. of sensing distance at 2 C within temperature range of 2 C to 7 C ±1% max. of sensing distance at 2 C within temperature range of C to 7 C Ambient humidity Operating: % to 9%, Storage: % to 9% Voltage influence ±1% max. of sensing distance in rated voltage range ±1% Insulation resistance MΩ min. (at VDC) between current carry parts and case Dielectric strength 1, VAC at /6 Hz for 1 min between current carry parts and case Vibration resistance to Hz, 1.-mm double amplitude for 2 hours each in, Y and Z directions Shock resistance m/s 2, times each in, Y and Z directions 1, m/s 2, times each in, Y and Z directions Standard and listings (See note.) IEC629: IP67, Degree of protection EN697--2: EMC Connection method -WP models: Pre-wired models (Standard length: 2 m) -M1 models: M12 -pin connector models -M models: M8 -pin connector models Weight Pre-wired model Approx. 6 g Approx. 8 g (packaged) M12 connector model M12 connector models: Approx. 2 g Approx. g M8 connector models: Approx. 1 g Material Case Stainless steel or brass-nickel plated Brass-nickel plated Sensing surface PBT Cable PVC Clamping nut Brass-nickel plated Note 1. The response frequency is an average value. Measurement conditions are as follows: standard target, a distance of twice the standard target distance between targets, and a setting distance of half the sensing distance. 2. When using any model at an ambient temperature between C and 2 C and a power voltage between and 2 VDC, use a load current of ma max.,. For USA and CANADA : use class 2 circuit only. E2A Cylindrical Proximity Sensor
5 DC -wire Models Item Size M18 M Type Shielded Non-shielded Shielded Non-shielded Non-shielded E2A-M18@S8-@@-B1 E2A-M18@S8-@@-B2 E2A-M18@S8-@@-C1 E2A-M18@S8-@@-C2 E2A-M18@N16-@@-B1 E2A-M18@N16-@@-B2 E2A-M18@N16-@@-C1 E2A-M18@N16-@@-C2 E2A-M@S1-@@-B1 E2A-M@S1-@@-B2 E2A-M@S1-@@-C1 E2A-M@S1-@@-C2 E2A-MKN2-@@-B1 E2A-MKN2-@@-B2 E2A-MKN2-@@-C1 E2A-MKN2-@@-C2 E2A-MLN-@@-B1 E2A-MLN-@@-B2 E2A-MLN-@@-C1 E2A-MLN-@@-C2 Sensing distance 8 mm±% 16 mm±% 1 mm±% 2 mm±% mm±% Setting distance to 6. mm to 12.8 mm to 12 mm to 16 mm to 2 mm Differential travel Target Standard target (mild steel ST7) Response frequency Power supply voltage (operating voltage range) Current consumption (DC -wire) Output type Control output Load current (See note 2.) % max. of sensing distance Ferrous metal (The sensing distance decreases with non-ferrous metal.) mm mm 1 mm mm mm Hz Hz 2 Hz Hz Hz 12 to 2 VDC. Ripple (p-p): % max. ( to 2 VDC) ma max. -B models: PNP open collector -C models: NPN open collector 2 ma max. (2 VDC max.) Residual voltage 2 V max. (under load current of 2 ma with cable length of 2 m) Indicator Operation indicator (Yellow LED) Operation mode (with sensing object approaching) Protection circuit Ambient air temperature Temperature influence (See note 2.) -B1/-C1 models: NO -B2/-C2 models: NC For details, refer to the timing charts. Output reverse polarity protection, Power source circuit reverse polarity protection, Surge suppressor, Short-circuit protection Operating: C to 7 C, Storage: C to 8 C (with no icing or condensation) ±% max. of sensing distance at 2 C within temperature range of 2 C to 7 C ±1% max. of sensing distance at 2 C within temperature range of C to 7 C Ambient humidity Operating: % to 9%, Storage: % to 9% Voltage influence ±1% max. of sensing distance in rated voltage range ±1% Insulation resistance MΩ min. (at VDC) between current carry parts and case Dielectric strength 1, VAC at /6 Hz for 1 min between current carry parts and case Vibration resistance to Hz, 1.-mm double amplitude for 2 hours each in, Y and Z directions Shock resistance 1, m/s 2, times each in, Y and Z directions Standard and listings (See note.) IEC629: IP67, Degree of protection EN697--2: EMC Connection method -WP models: Pre-wired models (Standard length: 2 m) -M1 models: M12 -pin connector models -M models: M8 -pin connector models Weight Pre-wired model Approx. 16 g Approx. 28 g Approx. 28 g Approx. 7 g (packaged) M12 connector model Approx. 7 g Approx. 2 g Approx. 2 g Approx. 26 g Material Case Brass-nickel plated Sensing surface PBT Cable PVC Clamping nut Brass-nickel plated Note 1. The response frequency is an average value. Measurement conditions are as follows: standard target, a distance of twice the standard target distance between targets, and a setting distance of half the sensing distance. 2. When using any model at an ambient temperature between - C and -2 C and a power voltage between and 2 VDC, use a load current of ma max.. For USA and CANADA : use class 2 circuit only. E2A Cylindrical Proximity Sensor
6 Engineering Data Operating Range (Typical) Shielded Models Y E2A-M@S1 E2A-M18@S8 E2A-M12@S E2A-S8@S2/ E2A-M8@S2 Non-shielded Models Y E2A-MLN E2A-MKN2 E2A-M18@N16 E2A-M12@N8 E2A-S8@N/ E2A-M8@N Distance Y (mm) Distance Y (mm) Influence of Sensing Object Size and Materials Shielded Models E2A-S8@S2/M8@S2 E2A-M12@S E2A-M18@S8 t = 1 mm t = 1 mm Iron Iron Stainless steel Stainless steel (SUS) (SUS) Brass Aluminum Copper Brass Aluminum Copper.. 2. t = 1 mm Iron Stainless steel (SUS) Brass Aluminum Copper Side length of sensing object d (mm) Side length of sensing object d (mm) 2 6 Side length of sensing object d (mm) E2A-M@S t = 1 mm Iron Stainless steel (SUS) Brass Aluminum Copper Side length of sensing object d (mm) 6 E2A Cylindrical Proximity Sensor
7 Non-shielded t = 1 mm Iron Stainless steel (SUS) Brass Aluminum Copper t = 1 mm Iron Stainless steel (SUS) Brass Aluminum Copper E2A-M18@N16 t = 1 mm Iron Stainless steel (SUS) Brass Aluminum Copper 2 Side length of sensing object d (mm) 2 Side length of sensing object d (mm) Side length of sensing object d (mm) E2A-MKN2 t = 1 mm 2 1 Iron Stainless steel (SUS) Brass Aluminum Copper t = 1 mm Iron Stainless steel (SUS) Brass Aluminum Copper Side length of sensing object d (mm) Side length of sensing object d (mm) E2A Cylindrical Proximity Sensor 7
8 Operation PNP Output NO Operation mode Model Timing chart Output circuit Non-sensing zone Sensing object (%) Rated sensing distance Sensing zone Proximity Sensor ON Yellow indicator OFF ON Control output OFF Proximity Sensor main circuits Brown Black Blue Load Note 1: With M8 connector models, there is no output reverse polarity protection diode. +V V M12 Connector Pin Arrangement (See note 2.) M8 Connector Pin Arrangement Note 2: Terminal 2 of the M12 connector is not used. NC E2A-@-@-B2 Non-sensing zone Sensing object (%) Rated sensing distance Sensing zone Proximity Sensor ON Yellow indicator OFF ON Control output OFF Proximity Sensor main circuits Brown Black (M8 connector: ) Blue Load Note 1: With M8 connector models, there is no output reverse polarity protection diode. +V V M12 Connector Pin Arrangement (See note 2.) M8 Connector Pin Arrangement Note 2: Terminal of the M12 connector is not used. 8 E2A Cylindrical Proximity Sensor
9 NPN Output NO Operation mode Model Timing chart Output circuit Non-sensing zone Sensing object (%) Rated sensing distance Sensing zone Proximity Sensor ON Yellow indicator OFF ON Control output OFF Proximity Sensor main circuits Brown Black Blue Load Note 1: With M8 connector models, there is no output reverse polarity protection diode. +V V M12 Connector Pin Arrangement (See note 2.) M8 Connector Pin Arrangement Note 2: Terminal 2 of the M12 connector is not used. NC E2A-@-@-C2 Non-sensing zone Sensing object (%) Rated sensing distance Sensing zone Proximity Sensor ON Yellow indicator OFF Proximity Sensor main circuits Brown Black Blue Load +V (M8 connector: ) V ON Control output OFF Note 1: With M8 connector models, there is no output reverse polarity protection diode. M12 Connector Pin Arrangement (See note 2.) M8 Connector Pin Arrangement Note 2: Terminal of the M12 connector is not used. E2A Cylindrical Proximity Sensor 9
10 Dimensions Note:All units are in millimeters unless otherwise indicated. Pre-wired Models (Shielded) Pre-wired Models (Non-shielded) 27 1 E2A-S8KN-WP-@@ dia. Note 1. -dia. vinyl-insulated round cable with conductors (conductor cross section: Note 1. -dia. vinyl-insulated round cable with conductors (conductor cross section: E2A-M12KS-WP-@@ E2A-M12KN8-WP-@@ dia. Note 1. -dia. vinyl-insulated round cable with conductors (conductor cross section: Note 1. -dia. vinyl-insulated round cable with conductors (conductor cross section: E2A-M18KS8-WP-@@ E2A-M18KN16-WP-@@ M18 1 Note 1. -dia. vinyl-insulated round cable with conductors (conductor cross section: 1. dia. M18 1 Note 1. -dia. vinyl-insulated round cable with conductors (conductor cross section: E2A-MKS1-WP-@@ 6 6. E2A-MKN2-WP-@@ M 1. Note 1. -dia. vinyl-insulated round cable with conductors (conductor cross section: 26.6 dia. M 1. Note 1. -dia. vinyl-insulated round cable with conductors (conductor cross section: E2A Cylindrical Proximity Sensor
11 E2A-S8LN-WP-@@ dia. Note 1. -dia. vinyl-insulated round cable with conductors (conductor cross section: Note 1. -dia. vinyl-insulated round cable with conductors (conductor cross section: E2A-M12LS-WP-@@ E2A-M12LN8-WP-@@ dia. Note 1. -dia. vinyl-insulated round cable with conductors (conductor cross section: E2A-M18LS8-WP-@@ Note 1. -dia. vinyl-insulated round cable with conductors (conductor cross section: E2A-M18LN16-WP-@@ M18 1 E2A-MLS1-WP-@@ Note 1. -dia. vinyl-insulated round cable with conductors (conductor cross section: 6 1. dia. E2A-MLN-WP-@@ M Note 1. -dia. vinyl-insulated round cable with conductors (conductor cross section: 26.6 dia. M 1. M 1. Note 1. -dia. vinyl-insulated round cable with conductors (conductor cross section: Note 1. -dia. vinyl-insulated round cable with conductors (conductor cross section: Mounting Hole Cutout Dimensions F External diameter of Proximity Sensor Dimension F (mm) M8 8. dia. +. M dia. +. M dia. +. M. dia. +. E2A Cylindrical Proximity Sensor 11
12 M12 Connector Models (Shielded) M12 Connector Models (Non-shielded) dia. Note: Operation indicator (yellow LED, 9 ) Note: Operation indicator (yellow LED, 9 ) E2A-M12KS-M1-@@ E2A-M12KN8-M1-@@ dia. Note: Operation indicator (yellow LED, 9 ) Note: Operation indicator (yellow LED, 9 ) E2A-M18KS8-M1-@@ E2A-M18KN16-M1-@@ M18 1 Note: Operation indicator (yellow LED, 9 ) 1. dia. M18 1 Note: Operation indicator (yellow LED, 9 ) E2A-MKS1-M1-@@ 8 6 E2A-MKN2-M1-@@ dia. M 1. Note: Operation indicator (yellow LED, 9 ) M 1. Note: Operation indicator (yellow LED, 9 ) 12 E2A Cylindrical Proximity Sensor
13 E2A-S8LN-M1-@@ E2A-M8LN-M1-@@ dia. Note: Operation indicator (yellow LED, 9 ) Note: Operation indicator (yellow LED, 9 ) E2A-M12LS-M1-@@ E2A-M12LN8-M1-@@ dia. Note: Operation indicator (yellow LED, 9 ) Note: Operation indicator (yellow LED, 9 ) E2A-M18LS8-M1-@@ E2A-M18LN16-M1-@@ 1. dia. M18 1 Note: Operation indicator (yellow LED, 9 ) M18 1 Note: Operation indicator (yellow LED, 9 ) E2A-MLS1-M1-@@ E2A-MLN-M1-@@ dia. M 1. M 1. Note: Operation indicator (yellow LED, 9 ) Note: Operation indicator (yellow LED, 9 ) M8 Connector Models (Shielded) M8 Connector Models (Non-shielded) E2A-S8KS2-M-@@ E2A-S8KN-M-@@ dia. Note: Operation indicator (yellow LED, 9 ) Note: Operation indicator (yellow LED, 9 ) E2A-S8LS2-M-@@ E2A-S8LN-M-@@ dia. Note: Operation indicator (yellow LED, 9 ) Note: Operation indicator (yellow LED, 9 ) E2A Cylindrical Proximity Sensor 1
14 Precautions Safety Precautions Power Supply Do not impose an excessive voltage on the E2A, otherwise it may be damaged. Do not impose AC current ( to 2 VAC) on any DC model, otherwise it may be damaged. Load Short-circuit Do not short-circuit the load, or the E2A may be damaged. The E2A s short-circuit protection function will be valid if the polarity of the supply voltage imposed is correct and within the rated voltage range. Correct Use Designing Power Reset Time The Proximity Sensor is ready to operate within ms after power is supplied. If power supplies are connected to the Proximity Sensor and load respectively, be sure to supply power to the Proximity Sensor before supplying power to the load. Effects of Surrounding Metal When mounting the E2A within a metal panel, ensure that the clearances given in the following table are maintained. l Wiring Be sure to wire the E2A and load correctly, otherwise it may be damaged. Connection with No Load Be sure to insert loads when wiring. Make sure to connect a proper load to the E2A in operation, otherwise it may damage internal elements. Do not expose the product to flammable or explosive gases. Do not disassemble, repair, or modify the product. Power OFF The Proximity Sensor may output a pulse signal when it is turned OFF. Therefore, it is recommended that the load be turned OFF before turning OFF the Proximity Sensor. Power Supply Transformer When using a DC power supply, make sure that the DC power supply has an insulated transformer. Do not use a DC power supply with an auto-transformer. Mutual Interference When installing two or more Sensors face-to-face or side-by-side, ensure that the minimum distances given in the following table are maintained. Type Dimension M8 M12 M18 M Shielded l (See note 1.) m Short barrel (Unit: mm) Long barrel (See note 2.) m d D 1. n l m d D n Note 1. In the case of using the supplied nuts. If true flash mounting is necessary, apply a free zone of 1. mm. 2. In the case of using the supplied nuts. If true flush mounting is necessary, apply a free zone of mm. D d dia. l n m Type Dimension M8 M12 M18 M Short barrel (Unit: mm) Long barrel Nonshielded Shielded A B Nonshielded A B E2A Cylindrical Proximity Sensor
15 Wiring High-tension Lines Wiring through Metal Conduit: If there is a power or high-tension line near the cable of the Proximity Sensor, wire the cable through an independent metal conduit to prevent against Proximity Sensor damage or malfunctioning. Cable Extension Standard cable length is less than 2 m. The tractive force is N. Mounting The Proximity Sensor must not be subjected to excessive shock with a hammer when it is installed, otherwise the Proximity Sensor may be damaged or lose its water-resistivity. Do not tighten the nut with excessive force. A washer must be used with the nut. Maintenance and Inspection Periodically perform the following checks to ensure stable operation of the Proximity Sensor over a long period of time. 1. Check for mounting position, dislocation, looseness, or distortion of the Proximity Sensor and sensing objects. 2. Check for loose wiring and connections, improper contacts, and line breakage.. Check for attachment or accumulation of metal powder or dust.. Check for abnormal temperature conditions and other environmental conditions.. Check for proper lighting of indicators (for models with a set indicator.) Never disassemble or repair the Sensor. Environment Water Resistivity Do not use the Proximity Sensor underwater, outdoors, or in the rain. M8 M12 M18 M Type Torque Stainless steel type 9 Nm Brass type Nm Nm 7 Nm 18 Nm Operating Environment Be sure to use the Proximity Sensor within its operating ambient temperature range and do not use the Proximity Sensor outdoors so that its reliability and life expectancy can be maintained. Although the Proximity Sensor is water resistive, a cover to protect the Proximity Sensor from water or water-soluble machining oil is recommended so that its reliability and life expectancy can be maintained. Do not use the Proximity Sensor in an environment with chemical gas (e.g., strong alkaline or acid gasses including nitric, chromic, and concentrated sulfuric acid gases). Inrush Current A load that has a large inrush current (e.g., a lamp or motor) will damage the Proximity Sensor, in which case connect the load to the Proximity Sensor through a relay. E2A Cylindrical Proximity Sensor 1
16 <SUITABILITY FOR USE> OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of the products in the customer s application or use of the products. Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will be used. <CHANGE IN SPECIFICATIONS> Product specifications and accessories may be changed at any time based on improvements and other reasons. Consult with your OMRON representative at any time to confirm actual specifications of purchased product. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by.97. To convert grams into ounces, multiply by.27. In the interest of product improvement, specifications are subject to change without notice. 16
17 Terms and Conditions of Sale 1. Offer; Acceptance. These terms and conditions (these "Terms") are deemed part of all quotes, agreements, purchase orders, acknowledgments, price lists, catalogs, manuals, brochures and other documents, whether electronic or in writing, relating to the sale of products or services (collectively, the "Products") by Omron Electronics LLC and its subsidiary companies ( Omron ). Omron objects to any terms or conditions proposed in Buyer s purchase order or other documents which are inconsistent with, or in addition to, these Terms. 2. Prices; Payment Terms. All prices stated are current, subject to change without notice by Omron. Omron reserves the right to increase or decrease prices on any unshipped portions of outstanding orders. Payments for Products are due net days unless otherwise stated in the invoice.. Discounts. Cash discounts, if any, will apply only on the net amount of invoices sent to Buyer after deducting transportation charges, taxes and duties, and will be allowed only if (i) the invoice is paid according to Omron s payment terms and (ii) Buyer has no past due amounts.. Interest. Omron, at its option, may charge Buyer 1-1/2% interest per month or the maximum legal rate, whichever is less, on any balance not paid within the stated terms.. Orders. Omron will accept no order less than $2 net billing. 6. Governmental Approvals. Buyer shall be responsible for, and shall bear all costs involved in, obtaining any government approvals required for the importation or sale of the Products. 7. Taxes. All taxes, duties and other governmental charges (other than general real property and income taxes), including any interest or penalties thereon, imposed directly or indirectly on Omron or required to be collected directly or indirectly by Omron for the manufacture, production, sale, delivery, importation, consumption or use of the Products sold hereunder (including customs duties and sales, excise, use, turnover and license taxes) shall be charged to and remitted by Buyer to Omron. 8. Financial. If the financial position of Buyer at any time becomes unsatisfactory to Omron, Omron reserves the right to stop shipments or require satisfactory security or payment in advance. If Buyer fails to make payment or otherwise comply with these Terms or any related agreement, Omron may (without liability and in addition to other remedies) cancel any unshipped portion of Products sold hereunder and stop any Products in transit until Buyer pays all amounts, including amounts payable hereunder, whether or not then due, which are owing to it by Buyer. Buyer shall in any event remain liable for all unpaid accounts. 9. Cancellation; Etc. Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Omron against all related costs or expenses.. Force Majeure. Omron shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority. 11. Shipping; Delivery. Unless otherwise expressly agreed in writing by Omron: a. Shipments shall be by a carrier selected by Omron; Omron will not drop ship except in break down situations. b. Such carrier shall act as the agent of Buyer and delivery to such carrier shall constitute delivery to Buyer; c. All sales and shipments of Products shall be FOB shipping point (unless otherwise stated in writing by Omron), at which point title and risk of loss shall pass from Omron to Buyer; provided that Omron shall retain a security interest in the Products until the full purchase price is paid; d. Delivery and shipping dates are estimates only; and e. Omron will package Products as it deems proper for protection against normal handling and extra charges apply to special conditions. 12. Claims. Any claim by Buyer against Omron for shortage or damage to the Products occurring before delivery to the carrier must be presented in writing to Omron within days of receipt of shipment and include the original transportation bill signed by the carrier noting that the carrier received the Products from Omron in the condition claimed. 1. Warranties. (a) Exclusive Warranty. Omron s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABIL- ITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron s sole obligation hereunder shall be, at Omron s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See or contact your Omron representative for published information. 1. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. 1. Indemnities. Buyer shall indemnify and hold harmless Omron Companies and their employees from and against all liabilities, losses, claims, costs and expenses (including attorney's fees and expenses) related to any claim, investigation, litigation or proceeding (whether or not Omron is a party) which arises or is alleged to arise from Buyer's acts or omissions under these Terms or in any way with respect to the Products. Without limiting the foregoing, Buyer (at its own expense) shall indemnify and hold harmless Omron and defend or settle any action brought against such Companies to the extent based on a claim that any Product made to Buyer specifications infringed intellectual property rights of another party. 16. Property; Confidentiality. Any intellectual property in the Products is the exclusive property of Omron Companies and Buyer shall not attempt to duplicate it in any way without the written permission of Omron. Notwithstanding any charges to Buyer for engineering or tooling, all engineering and tooling shall remain the exclusive property of Omron. All information and materials supplied by Omron to Buyer relating to the Products are confidential and proprietary, and Buyer shall limit distribution thereof to its trusted employees and strictly prevent disclosure to any third party. 17. Export Controls. Buyer shall comply with all applicable laws, regulations and licenses regarding (i) export of products or information; (iii) sale of products to forbidden or other proscribed persons; and (ii) disclosure to non-citizens of regulated technology or information. 18. Miscellaneous. (a) Waiver. No failure or delay by Omron in exercising any right and no course of dealing between Buyer and Omron shall operate as a waiver of rights by Omron. (b) Assignment. Buyer may not assign its rights hereunder without Omron's written consent. (c) Law. These Terms are governed by the law of the jurisdiction of the home office of the Omron company from which Buyer is purchasing the Products (without regard to conflict of law principles). (d) Amendment. These Terms constitute the entire agreement between Buyer and Omron relating to the Products, and no provision may be changed or waived unless in writing signed by the parties. (e) Severability. If any provision hereof is rendered ineffective or invalid, such provision shall not invalidate any other provision. (f) Setoff. Buyer shall have no right to set off any amounts against the amount owing in respect of this invoice. (g) Definitions. As used herein, including means including without limitation ; and Omron Companies (or similar words) mean Omron Corporation and any direct or indirect subsidiary or affiliate thereof. Certain Precautions on Specifications and Use 1. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer s application or use of the Product. At Buyer s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer s application, product or system. Buyer shall take application responsibility in all cases but the following is a non-exhaustive list of applications for which particular attention must be given: (i) Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document. (ii) Use in consumer products or any use in significant quantities. (iii) Energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. (iv) Systems, machines and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to this Product. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON S PRODUCT IS PROP- ERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. 2. Programmable Products. Omron Companies shall not be responsible for the user s programming of a programmable Product, or any consequence thereof.. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron s Warranty and Limitations of Liability.. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron s representative at any time to confirm actual specifications of purchased Product.. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions.
18 OMRON INDUSTRIAL AUTOMATION THE AMERICAS HEADQUARTERS Schaumburg, IL USA OMRON CANADA, INC. HEAD OFFICE Toronto, ON, Canada OMRON ELECTRONICS DE MEICO HEAD OFFICE México DF OMRON ELECTRONICS DE MEICO SALES OFFICE Apodaca, N.L OMRON ARGENTINA SALES OFFICE Cono Sur OMRON CHILE SALES OFFICE Santiago OTHER OMRON LATIN AMERICA SALES OMRON ELETRÔNICA DO BRASIL LTDA HEAD OFFICE São Paulo, SP, Brasil OMRON EUROpE B.V. Wegalaan 67-69, NL-212 JD, Hoofddorp, The Netherlands. Tel: +1 () Fax: +1 () Cat. No. D96-D1-1B 12/1 Note: Specifications are subject to change. 21 Omron Electronics LLC Printed in U.S.A.
E2A Single Sensing Distance
Cylindrical Inductive E2A Single Distance High quality for extra long life in daily use wide portfolio range through modular concept designed and tested for extra long life IP67 and IP69k for highest protection
E2K-L. Liquid Level Sensor. Applications. Ordering Information. E-68 Proximity Sensors
Liquid Level Sensor Installation on pipes. Sensing by means electrostatic capacity and is not influenced by the color of the pipe or liquid. Available in 8 to mm dia. and to mm dia. models to enable sensing
Part number NPN E2EM-X2C1 E2EM-X2C2 PNP E2EM-X2B1 E2EM-X2B2 NPN E2EM-X4C1 E2EM-X4C2 PNP E2EM-X4B1 E2EM-X4B2
R Extended Range Inductive Prox Greater Sensing Distance Offers Greater Design Flexibility H Sensing distances approximately 1.5 to 2 times larger than that of any conventional Sensor H Reduces problems
E2FM. Inductive Proximity Sensor in full metal housing. Application. Continuous Impact Test. Brush Test
Inductive Proximity Sensor in full metal housing Full body stainless steel housing for highest mechanical protection Low frequency modulation for metal chip immunity Flame retardant cable for high protection
General-purpose Relays
General-purpose Relays MK-S New Model General-purpose Relays Featuring Mechanical Indicator and Lockable Test Button Built-in operation indicator (mechanical and LED), and new models with lockable test
EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.
Wafer-carrier Mounting Photomicrosensors EE-SPY1/ CSM_EE-SPY1 DS_E_3_ Photomicrosensors for detecting wafer-carrier mounting. The mounting position is set with a pedestal. The contact surface with the
VAQ. Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment. Pushbutton Switch (Cylindrical 10.5-dia.
Pushbutton Switch (Cylindrical 10.5-dia.) CSM DS_E_4_4 Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment Momentary operation and lock. available in six colors.
E2EL Ø 6,5 M8 / Plug M8 M8 / Plug M12 E2EL
High Frequency Inductive Proximity Sensor Increased response frequency for high speed applications Max 5 khz, switching frequency M8 or dia 6.5 mm housing Brass or stainless steel housing Ordering Information
Type Terminal Coil Contact form Model
General Purpose Relay MK Exceptionally reliable general purpose relay. Long life (minimum 100,000 electrical operations) assured by silver contacts. Built-in operation indicator (mechanical, LED), diode
Proximity Sensor with All-stainless Housing
NEW Proximity Sensor with All-stainless Housing Highly Durable Proximity Sensor for Tough Environments One-piece completely stainless-steel housing with a face thickness of.8 mm! The face thickness is
Tab (#110) terminal Actuator
Snap Action Switch SS Subminiature Snap Action Switch Economical, subminiature snap action switch offers long service life (30 million operations minimum) All models are free from overtravel restrictions,
CQM1-SF200/CS1W-SF200
Safety Relay Unit ( I/O Unit Type) CQM1-SF200/CS1W-SF200 CSM_CQM1-SF200_CS1W-SF200_DS_E_2_1 A Safety Relay Unit That Functions as a I/O Unit. Less Installation Space and Wiring Required. Safety Relay Unit
EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws
Compact Pre-wired Photomicrosensor with Built-in Amplifier (Non-modulated) CSM DS_E_7_2 Meeting Customer Needs with Compact Sensors that Mount with M Screws Both light-on and dark-on outputs provided.
Cylindrical Proximity Sensor
Cylindrical Proximity Sensor A New Series of Easy-to-use and Tough Models with a Yellow Indicator New series of TL-X2C1-GE models with improved performance over the previous TL-X-E models. Also, in addition
Ordering Information. Cylindrical Proximity Sensor E2E/E2E2
Cylindrical Sensor E2E/E2E2 A New Series of Easy-to-use and Tough E2E/E2E2 Models Long-size E2E2 Sensor Conforms to CENELEC Ideal for a variety of applications. With a metal connector that can be tightened
Photoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units)
Photoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units) E3C-LDA Series All three beam types provide ample long-distance detection of 1,000 mm for Diffuse Reflective Models.
Resolution (divisions) Pre-wired Model E6F-AB3C 360P/R 2M *2 Pre-wired Connector E6F-AB3C-C 360P/R 2M *2 Model (2 m) NPN open collector BCD 360
Absolute 60-mm-dia. Rotary Encoder CSM DS_E_7_ Rugged Rotary Encoder Absolute model. External diameter of 60 mm. Resolution of up to 1,024 (10-bit). IP65 oil-proof protection. Strong shaft. Radial: 120
How To Read A Pipe From A Sensor
Liquid Level Sensor Installation on pipes. Sensing by means electrostatic capacity and is not influenced by the color of the pipe or liquid. Available in 8 to mm dia. and to mm dia. models to enable sensing
Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles
Clear Glass Sensor Optimum Sensor for Detecting Transparent Glass and Plastic Bottles E3S-CR67/62 Retroreflective Sensor smoothly detects 5-mm gaps. Detects transparent bottles that have a lens effect.
G6K-2F G6K-2F-Y G6KU-2F-Y
Low Signal Relay G6K Fourth generation design. Design based on worldwide communications, computer peripheral and office automation relay requirements. Offers excellent board space savings. Meets 2.5 kv
Sensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector.
Photoelectric Sensor with Built-in Amplifier Photoelectric Sensor with built-in amplifier is applicable to a wide variety of lines and ensures a longer sensing distance than any other model. User-friendly
CX-One Ver.4. FA Integrated Tool Package CX-One. Greater Integration with the CX-One. Features
FA Integrated Tool Package CX-One CX-One Ver.4 CSM_CX-One_DS_E_3_1 Greater Integration with the CX-One The CX-One is a comprehensive software package that integrates PLC Programming Software with Support
Ordering Information. Latching Relay G2AK. Model Number Legend G2AK-@@@@@ 1 2 3 4 5. Magnetic Latching Version of G2A Ideal for Sequence Control
Latching Relay CSM DS_E_4_1 Magnetic Latching Version of G2A Ideal for Sequence Control Double-winding latch system with continuous rating. Terminals pulled from the respective junctions between the built-in
HL-5000. Economical, Miniature Limit Switch Boasting Rigid Construction. General-purpose Limit Switch. Model Number Structure.
General-purpose Limit Switch CSM DS_E_3_ Economical, Miniature Limit Switch Boasting Rigid Construction The Head, Box, and Cover mate with ridged surfaces to maintain strength. A unique Head structure
E8F2. Pressure Sensor with Easy-to-Read LED Display. Digital Pressure Sensor. Ordering Information. Sensors (Refer to Dimensions on page 7.
Digital Sensor CSM DS_E_4_3 Sensor with Easy-to-Read LED Display status can be checked at a glance from the digital display and bar display. Measurement pressure prevents incorrect outputs due to momentary
Terms and Conditions. 3012436v2 12285.01010
Terms and Conditions ACCEPTANCE. Except as otherwise agreed in a written agreement signed by both parties, these Terms and Conditions will govern Buyer s purchase order. BI Technologies acceptance of Buyer
Capacitive Prox E2K-X
Capacitive Prox Threaded, Cylindrical Sensor Detects Metallic and Non-metallic Objects Permits non-contact detection of metallic and non-metallic objects such as glass, wood, water, oil and plastic Allows
Tina 2A/B Adaptor unit
Original instructions Tina 2A/B Adaptor unit ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this
Original instructions Tina 3A/Aps Adaptor unit
Original instructions Tina 3A/Aps Adaptor unit ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this
E3T Miniature Photoelectric Sensors
E3T Miniature Photoelectric Sensors Ultra-Compact with Visible Red Beam»» Ultra slim to fit and perform where others won't»» Visible red beam for simple set-up»» Five different sensing methods E3T Miniature
SELLING TERMS AND CONDITIONS
SELLING TERMS AND CONDITIONS 1. The Agreement. All sales by Sterling Machinery, Inc., an Arkansas corporation (the Seller ) to the purchaser of Seller s Goods (the Buyer ) shall be governed by the following
Liquid Leakage Sensor Amplifier
9 Liquid Leakage Sensor Amplifier Space-saving Sensor Amplifier reliably detects a wide variety of liquids ranging from water to chemical liquids with low conductivity 1 Detects leakage of liquid such
E3Z. Ordering Information. Photoelectric Sensor with Built-in Amplifier. Compact Sensor Offers Long Sensing Distance and Superior Noise-Immunity
Photoelectric Sensor with Built-in Amplifier Compact Sensor Offers Long Sensing Distance and Superior Noise-Immunity H Photo-IC provides long sensing distance: 15 m for through-beam, 4 m for retroreflective,
SolarEdge Technologies Ltd.
SolarEdge Technologies Ltd. GENERAL TERMS AND CONDITIONS 1. General. This document, entitled General Terms and Conditions (referred to herein as the Agreement ), forms an integral part of the quotation
CMOS Laser Sensor with Built-in Amplifier
New Product CMOS Laser Sensor with Built-in Amplifier ZX0 Stable Detection of Level Differences in the Order of 0.1 mm Dependable detection without being influenced by color, material, or surface conditions.
Phase-sequence Phase-loss Relay
New Product Phase-sequence Phase-loss Relay K8DS-PH Three-phase Phase-sequence Phase-loss Relay Using Voltage Detection Method Lineup includes a 17.5-mm slim, compact model. Greater resistance to inverter
Cross-beam scanning system to detect slim objects. 100 mm 3.937 in
891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC
Cylindrical Proximity Sensor
Cylindrical Proximity Sensor A New Series of Easy-to-use and Tough Models Long-size E2E2 Proximity Sensor Conforms to CENELEC Ideal for a variety of applications. With a metal connector that can be tightened
Absolute Rotary Encoder E6CP
Absolute Rotary Encoder Absolute Rotary Encoders with Gray Code Output Gray code output decreases output errors Lightweight plastic housing Used with Omron s H8PS Cam Positioner, this encoder detects the
PDQ Workholding LLC Terms and Conditions of Sale
PDQ Workholding LLC Terms and Conditions of Sale Unless otherwise specifically stated in the offer to sell goods submitted herewith ( Sales Quotation ), these Terms and Conditions establish the rights,
CM Series. Most Diverse and Flexible Line of Coded Magnetic Safety Interlock Switches and Controllers. Description. Safety Interlock Switches
R Safety Interlock Switches CM Series Most Diverse and Flexible Line of Coded Magnetic Safety Interlock Switches and Controllers Combine door switch monitoring and E-stop monitoring by using the CM-S41
Standard Terms & Conditions of Quotation and Sale
S E N S A T A T E C H N O L O G I E S, I N C. Standard Terms & Conditions of Quotation and Sale TERMS & CONDITIONS OF QUOTATION BUYER S OFFER RESULTING FROM SELLER S QUOTATION IS EXPRESSLY CONDITIONED
Smile 11 AS-i Emergency stop with safe AS-i input node
Original instructions Smile 11 AS-i Emergency stop with safe AS-i input node SAFETY AT WORK ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand
Inductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12
pre-wired E3FC-TN11 2M *1 E3FC-TP11 2M *1
Photoelectric sensors in M8 stainless steel housing EFC Best durability for wash-down applications High grade steel housing (SUS6L) Withstands heat shock conditions Epoxy resin preventing water ingress
Infineon Technologies North America Corp. Terms and Conditions of Sale
Infineon Technologies North America Corp. Terms and Conditions of Sale 1. GENERAL 1.1 Contract Terms. These Terms and Conditions of Sale (the Agreement ) shall apply to any offer made by Infineon Technologies
Price List January 1, 2015
Price List January 1, 2015 Cement Lined Price List Certification and General Installation Certification All Ductile Iron Spooling manufactured by is made in accordance with current ANSI/AWWA- C115/A21.15
Type Sealing Poles Contacts Rated voltage Model Standard d Flux-tight 4 poles oes 3PST-NO, SPST-NC 24 VDC G7SA-3A1B 3PST-NO, 3PST-NC
Safety Relay Slim Safety Relays Conforming to EN Standards The forcibly guided contact in the assures safe operation (EN50205 Class A, approved by VDE.) Ideal for use in safety circuits in press machinery,
Ordering Information. Specifications. Electrode Holder PS-@S(R)/-31. Electrode Holders. Accessories (Order Separately)
Holder PS-@S(R)/-31 Separate Holders for Water Supply and Drainage Control in Buildings. Small, Lightweight Holders for Use as Built-in Components. The PS-@S(R) are separate Holders that allow the s to
PURCHASE ORDER ACKNOWLEGMENT AND TERMS AND CONDITIONS
PURCHASE ORDER ACKNOWLEGMENT AND TERMS AND CONDITIONS 1. REJECTION OF ORDERS WITH CONTRADICTORY TERMS-All orders submitted by a buyer are subject to approval by an officer or other authorized official
PROTECTO 401 Price List
Price List January 1, 2015 Protecto 401 Price List Certification and General Installation Certification All Ductile Iron Spooling manufactured by is made in accordance with current ANSI/AWWA- C115/A21.15
TERMS AND CONDITIONS
TERMS AND CONDITIONS 1. Definitions. Buyer means the person, corporation or other entity purchasing Products from Seller. Products means all goods and materials to be provided pursuant to this Sales Acknowledgment.
D2QW D2QW-@@@@@- @ - @ 1 2 3 4 5 6 7. Sealed long stroke slide-contact switch for reliable ON/OFF action even in severe environmental conditions.
Sealed long stroke slide-contact switch for reliable ON/OFF action even in severe environmental conditions. Extra-long stroke even without levers. (:.7 mm) Clip contacts with highly reliable slide contact
User s Manual Before using the inverter, you need to read and save the safety instructions.
User s Manual Before using the inverter, you need to read and save the safety instructions. STI SERIES (STI200, STI300, STI500, STI700, STI1000) Power Frequency Pure Sine Wave Inverter The information
Slim Relay G2RV. Features. Test switch operation. Protection cover: lock. Protection cover: unlock. Protection cover open. Protection cover close
Slim Relay GRV The only truly industrial 6 mm relay Lockable test switch models now available. Large plug-in terminals for reliable connection. LED indicator and mechanical flag for status indication.
NX-SL/SI/SO. NX-series Safety Control Units. Integration of Safety into Machine Automation Enables Simple, Flexible System Configuration.
NX-series Safety Control Units NX-SL/SI/SO CSM_NX-SL_SI_SO_E_1_1 Integration of Safety into Machine Automation Enables Simple, Flexible System Configuration. EN ISO13849-1 (PLe/Safety Category4), IEC 61508
Maintenance information. DRT2-series. Remote I/O Terminals Relay Output Terminals. DRT2-series. DRT2-series Smart Slave Analog I/O Terminals
CS-series Net Unit CSM DS_E_5_1 A Net Unit for the CS Series That Boasts Industry-leading Performance and Functions Features Allows control of up to 32,000 points (2,000 words) per master, and ensures
Three-phase Asymmetry and Phase-sequence Phase-loss Relay K8AB-PA
Three-phase Asymmetry and Phase-sequence Phase-loss Relay K8AB-PA Ideal for 3-phase voltage asymmetry monitoring for industrial facilities and equipment. Monitor voltage asymmetry, phase sequence, and
Load Cell Amplifier Module. Instruction Manual LCA210-000
Load Cell Amplifier Module Instruction Manual LCA210-000 Table of Contents 1. General Description...3 2. Specifications...3 2.1 Electrical...3 2.2 Physical...4 3. Installation...4 3.1 Wiring Guidelines...4
DATA DETECTION TECHNOLOGIES LTD ("DATA") Terms and Conditions to Integrator Agreement
DATA DETECTION TECHNOLOGIES LTD ("DATA") Terms and Conditions to Integrator Agreement These DATA Terms and Conditions (the "Integrator Terms and Conditions") govern all and any transactions by which any
Color Mark Sensor with Red or Green LED E3S-VS
Color Mark Sensor with Red or Green LED Rugged IP67 Color Mark Sensor 1 ms response time Detects a wide variety of color marks PNP or NPN output ls Light-on/ Dark-on operation, wire selectable Vertical
GENERAL CABLE COMPANY LTD. TERMS AND CONDITIONS OF SALE (Canada)
GENERAL CABLE COMPANY LTD. TERMS AND CONDITIONS OF SALE (Canada) 1. ACCEPTANCE. This is an offer for General Cable Company Ltd. ( Seller ) to sell the product(s) ( Goods ) offered by it to the party to
G7SA. Ordering Information. Slim Plug-In Safety Relay. Slim Safety Relay for Machine Control. H Slim body only 13 x 24 x 50 mm
Slim Plug-In Safety Relay Slim Safety Relay for Machine Control H Slim body only 13 x 24 x 50 mm (six poles) H Four-pole and six-pole models are available H Terminal arrangement simplifies PCB pattern
Advantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
Terms and Conditions for Purchase Orders for Recycling Materials
Terms and Conditions for Purchase Orders for Recycling Materials This Agreement is made by and between AEROJET-GENERAL CORPORATION, an Ohio corporation with a place of business at Rancho Cordova, California
SPST-NO SPDT DPST-NO DPDT
PCB Relay Next-generation PCB Relay Available in 2 Models Low profile:. mm max. in height Contains no lead inside and features cadmium-free contacts ensuring environment-friendly use. Conforms to VDE0
PA5. Series. Quick-Connect Cables with Connectors. Simplifies sensor wiring. Wide variety of connectors attached to cables.
Quick-Connect Cables with Connectors PA Simplifies sensor wiring. Wide variety of connectors attached to cables. Series No wiring or staking work needed Shorter replacement time in unlikely event of sensor
Dimensional drawing. Connection type IME08-1B5NOZT0S IME08-1B5NSZT0S IME08-1B5POZT0S IME08-1B5PSZT0S. 3 x 0.14 mm². brn. L+ Schließer/ Öffner M.
Inductive sensor, IE series, IE08, DC-wire, Standard series, Flush Inductive sensor Sensing range.5 mm Short-circuit protection (pulsed) Dimensional drawing 8x Robust brass housing, nickelplated with fine
Ordering Information. Short Barrel Inductive Prox E2E3-WIREDC. Short Barrel 3-Wire Prox Sensors Meet IP67
R Short Barrel Inductive Prox E2E3-WIREDC Short Barrel 3-Wire Prox Sensors Meet IP67 H Thick nickel-plated brass barrel has wrench flats for easy installation H Solid potted internal circuitry withstands
Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual
Doc.No. NDP 192U-02 Electric Pump Controller CE-124P Instruction Manual 1. Parts Name and Function 1) POWER LED Indicate that CE-124P is powered up. 2) START/STOP KEY (SELECTOR KEY) Used to start and stop
TERMS AND CONDITIONS OF SALE. Quotations, Purchase Orders, Acknowledgements, Packing Lists/Slips, Invoices & Credits
Quotations, Purchase Orders, Acknowledgements, Packing Lists/Slips, Invoices & Credits All quotations of Seller ( Quotations ) and purchase orders of Buyer ( Purchase Orders ) shall be subject to these
General Product Retail Agreement
General Product Retail Agreement This agreement ("Agreement") is entered into on the day of, 200, by and between NATIONAL RURAL TELECOMMUNICATIONS COOPERATIVE, a District of Columbia corporation ("NRTC"
Specifications H8CA-S H8CA-S RATINGS. Approved by the following standards CHARACTERISTICS
Solid-State Counter/Timer 1/16 DIN, Easy-to-Operate Combination Counter and Timer Operation selectable as preset counter or timer 6-digit LCD Present Value: 8 mm (.32 in) Set Value: 4 mm (.16 in) Nonsignificant
Incremental Rotary Encoder E6B2
Incremental Rotary Encoder General-Purpose Rotary Encoder Withstands arge Shaft oads Wide variety of supply voltages and output forms Easy-to-adjust zero index (phase Z) with origin indicating function
PRODUCT SALES AGREEMENT
PRODUCT SALES AGREEMENT This Product Sales Agreement (this Agreement ) is made as of the day of, 201, by and between Georgia Tech Applied Research Corporation, a Georgia non-profit corporation ( Seller
General Terms and Conditions of Sale and Delivery BruggemannChemical U.S., Inc. Date: January 1, 2012. I. General
General Terms and Conditions of Sale and Delivery BruggemannChemical U.S., Inc. Date: January 1, 2012 I. General 1.1 The following general terms and conditions of sale and delivery (hereinafter General
QNX Software Systems or QSS means QNX Software Systems International Corporation.
INVOICE TERMS AND CONDITIONS OF SALE (QNX Software Systems designated below as "Seller") DEFINITIONS In these Terms: QNX Software Systems or QSS means QNX Software Systems International Corporation. "Software"
Model Number Structure
General-purpose Relay G2RS Slim and Space-saving Power Plug-in Relay Lockable test button models now available. Built-in mechanical operation indicator. Provided with nameplate. AC type is equipped with
COMPLIANCE WITH LAWS, CODES, AND STANDARDS
All products furnished by Jinan Meide Casting Co. Ltd, shall be in accordance with the following terms and conditions unless otherwise agreed to in writing: ACCEPTANCE AND COMPLETE AGREEMENT Buyer s order
Temperature Controllers E5CSL/E5CWL/E5EWL
Temperature Controllers E5CSL/E5CWL/ The Simple and New Temperature Controller is Released that Easily Achieves the Temperature Control. Easy to Read (Character Height E5CSL: 2.7 mm, E5CWL: 6.2 mm (PV),
Model Number Structure
General-purpose Relay G2RS Slim and Space-saving Power Plug-in Relay Lockable test button models now available. Built-in mechanical operation indicator. Provided with nameplate. AC type is equipped with
Small U-shaped Micro Photoelectric Sensor. Enables space saving and quick installation!
4 Small Micro Photoelectric Amplifier Built-in PM-44 SERIES PM-4 SERIES General terms and conditions... F- selection guide... P.44~ Related Information Glossary of terms / General precautions... P.39~
MAJOR EQUIPMENT PURCHASE CONTRACT
MAJOR EQUIPMENT PURCHASE CONTRACT CONSUMERS ENERGY COMPANY ONE ENERGY PLAZA JACKSON, MI 49201 ( Buyer ) ( Seller ) Date:, 20 Subject to the provisions of this Major Equipment Purchase Contract ( Contract
Evoqua Water Technologies LLC. ( Evoqua )
Evoqua Water Technologies LLC. ( Evoqua ) Remote Monitoring Services Terms and Conditions of Use These terms and conditions govern the use of Evoqua Link2Site sm Remote Monitoring Services whether the
Explosion proof enclosures
1 of 7 Explosion proof enclosures DE8 C 2 of 7 The Ex d enclosures are rugged and designed for harsh environment like: Oil and gas industry Chemical industry Pharmaceutical industry Agribusiness Without
END USER LICENSE AGREEMENT ( EULA )
END USER LICENSE AGREEMENT ( EULA ) PLEASE READ CAREFULLY THIS EULA IS A LEGAL AGREEMENT BETWEEN YOU, EITHER AS AN INDIVIDUAL, COMPANY OR OTHER LEGAL ENTITY (IN ANY CAPACITY REFERRED TO HEREIN AS END USER,
The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.
i800 AC Current Clamp Instruction Sheet Introduction The i800 AC Current Clamp, the Clamp, has been designed for use with multimeters, recorders, power analyzers, safety testers, etc., for accurate non-intrusive
Safety Manual BT50(T) Safety relay / Expansion relay
Safety Manual BT50(T) Safety relay / Expansion relay ABB Jokab Safety Varlabergsvägen 11, SE-434 39, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this document
Triton Systems of Delaware, LLC. Warranty Statement
Triton Systems of Delaware, LLC 21405 B Street 866.7.TRITON Triton Systems of Delaware, LLC Warranty Statement TRITON WARRANTY STATEMENT The Manufacturer warrants that the products delivered to a distributor
Adjustment functions for both span and shift have been incorporated
SENSORS FOR SERIES LED Type Wafer Alignment Sensor FX-0-F FT-F9 FD-F7 EX-F70/F60 M SH-7 FD-L4 M-DW The use of a safe LED light beam now allows for high precision detection with a resolution of 0!m (.8
OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS
OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS Photoelectric These sensors use light sensitive elements to detect objects and are made up of an emitter (light source) and a receiver. Four types of photoelectric
i410/i1010 AC/DC Current Clamp
/i1010 AC/DC Current Clamp Instruction Sheet Safety Information XW Read First: Safety Information To ensure safe operation and service of the current clamp, follow these instructions: Read all operating
D2SW-P. Sealed Subminiature Basic Switch. Ordering Information
Sealed Subminiature Basic Switch Sealed Basic Switch with Simplified Construction, Mounting Compatible with SS and D2SW Series. Sealing by using rubber packing means the switch can be used in dust-proof
SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors. 40-300 mm background suppression
Advanced line of miniature Asian style of photoelectric sensors 4-3 background suppression.7 m proximity, 15 with narrow beam 4 m polarized retroreflective 3 m LASER through beam Standard 3-wire output
