Slim Relay G2RV. Features. Test switch operation. Protection cover: lock. Protection cover: unlock. Protection cover open. Protection cover close

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "Slim Relay G2RV. Features. Test switch operation. Protection cover: lock. Protection cover: unlock. Protection cover open. Protection cover close"

Transcription

1 Slim Relay GRV The only truly industrial 6 mm relay Lockable test switch models now available. Large plug-in terminals for reliable connection. LED indicator and mechanical flag for status indication. Input type with gold plated contacts available. Transparent housing allows inspection of contact condition. Slim width to save space. Push-in terminals and accessories for easy wiring. Lloyd s approval (pending) Test switch type No test switch type PATENTED Features Test switch operation Protection cover: lock Protection cover: unlock Protection cover open Protection cover close Contact normal position Contact operated position (ON state) OMRON Lockable test switch can be used in this way: When the protection cover (located directly over the test switch) is closed, the test switch is retained in normal position (OFF state) by the protection cover. After opening the protection cover, the test switch can be unlocked. The test switch can then be moved to the operated position (ON state). After using the test switch, move it to the normal position (OFF state) and close the protection cover to prevent unwanted operation of the test switch. * Please check Precautions (Page. 7 : Precaution of test switch operation) when using test switch. Application of test switch: Example: Checking operation of Relays and sequence circuits. Slim Relay GRV

2 Model Number Structure Model Number @ Auxiliary Type Designation SL: Slim relay and socket combination. Wire Connection 7: Screw terminals 5: Push-in terminals 3. Relay LED 0: Without LED 4. Relay Test switch 0: No test switch type : Test switch type 5. Contact form AP: Input type Blank: Standard type 6. Input Voltage Note: LED indicator available on socket. Ordering Information Classification Relay and Socket Combinations No test switch type Test switch type Enclosure rating Input voltage Type of connection Test switch Contact form (SPDT) Standard type Input type Plug-in terminals General-purpose Unsealed AC/DC Screw terminals No GRV-SL700 GRV-SL700-AP Input voltage Standard type (No test switch type) Yes GRV-SL Push-in terminals No GRV-SL500 GRV-SL500-AP Contact form (SPDT) Yes GRV-SL Input type (No test switch type) Screw terminals Push-in terminals Screw terminals Push-in terminals VDC GRV-SL700 VDC GRV-SL500 VDC GRV-SL700-AP VDC GRV-SL500-AP VDC 4 VDC GRV-SL700 4 VDC GRV-SL500 4 VDC GRV-SL700-AP 4 VDC GRV-SL500-AP 4 VDC 4 VAC/DC GRV-SL700 4 VAC/DC GRV-SL500 4 VAC/DC GRV-SL700-AP 4 VAC/DC GRV-SL500-AP 4 VAC/DC 48 VAC/DC GRV-SL VAC/DC GRV-SL VAC/DC GRV-SL700-AP 48 VAC/DC GRV-SL500-AP 48 VAC/DC VAC GRV-SL700 VAC GRV-SL500 VAC GRV-SL700-AP VAC GRV-SL500-AP VAC 30 VAC GRV-SL VAC GRV-SL VAC GRV-SL700-AP 30 VAC GRV-SL500-AP 30 VAC Input voltage Contact form (SPDT) Standard type (Test switch type) Input type (Test switch type) Screw terminals Push-in terminals Screw terminals Push-in terminals 4 VDC GRV-SL70 4 VDC GRV-SL50 4 VDC VAC/DC GRV-SL70 4 VAC/DC GRV-SL50 4 VAC/DC Slim Relay GRV

3 Specifications Input Ratings Rated voltage Rated current * Must operate voltage Contact Ratings *) P level: λ 60 = /operation *) If a gold layer is destroyed, contact ratings of standard type are applicable. Characteristics Note: Values in the above table are the initial values. Must release voltage AC DC % of rated voltage AC (VA) Approx. 50 Hz 60 Hz Power consumption DC (mw) Approx. VDC ma 80% % mw ±% 4 VDC ma mw 4 VAC/DC. ma.5 ma 3.0 ma 0.5 VA 300 mw 48 VAC/DC 8.5 ma 9.0 ma 5. ma 0.4 VA 50 mw VAC 7. ma 7.5 ma VA VAC 7.3 ma 7.9 ma VA --- *) Rated currents are measured at 3 degrees Celsius (ambient) Number of poles Load Rated load Input voltage % of rated voltage Item Standard type (GRV-SL700, 500, 70, 50) Input type (GRV-SL700-AP, 500-AP) * pole Resistive load (cosφ = ) 6 A at 50 VAC; 6 A at 30 VDC Inductive load (cosφ = 0.4, L/R = 7 ms).5 A at 50 VAC; A at 30 VDC Resistive load (cosφ = ) 50 ma at 30 VAC; 50 ma at 36 VDC Rated carry current 6 A 50 ma Max. switching voltage 400 VAC, 5 VDC 30 VAC, 36 VDC Max. switching current 6 A 50 ma Max. switching power,500 VA 500 VA 80 W 60 W Failure rate (reference value) * ma at 5 VDC (P level) ma at 0 mvdc (P level) Item Standard type (GRV-SL700, 500, 70, 50) Input type (GRV-SL700-AP, 500-AP) Contact resistance 0 mω max. Operate (set) time 0 ms max. Release time 40 ms max. Max. operating frequency Mechanical: 8,000 operations/hr Electrical:,800 operations/hr (under rated load) Insulation resistance,000 MΩ min. (at 500 VDC) Dielectric strength 4,000 VAC, 50/60 Hz for min between coil and contacts*;,000 VAC, 50/60 Hz for min between contacts of same polarity Vibration resistance Destruction: to 55 to Hz, 0.50 mm single amplitude (.0 mm double amplitude) Malfunction: to 55 to Hz, 0.50 mm single amplitude (.0 mm double amplitude) Shock resistance Destruction:,000 m/s Malfunction: 00 m/s when energized; 0 m/s when not energized Endurance Mechanical: 5,000,000 operations min. Electrical: 0,000 Typical; NO 70,000 operations min. ; Mechanical: 5,000,000 operations min. Electrical: 5,000,000 operations min. NC 50,000 operations min. Ambient temperature Operating: 40 C to 55 C (with no icing or condensation) Ambient humidity Operating: 5% to 85% Weight Approx. 35 g Overvoltage category III Pollution degree Contact material AgSnIn AgSnIn + Gold Plating Creepage distance 7.0 mm Clearance distance 5.5 mm Slim Relay GRV 3

4 Approved Standards UL 508 (File No. E4643) Model Contact form Coil ratings Contact ratings Operations GRV-SL Series SPDT to 48 VDC 4 to 30 VAC 50 VAC 6 A (Resistive Load) 30 VDC 6 A (Resistive Load) 400 VAC A (Resistive Load) 6,000 IEC/VDE (EN 68) Contact form Coil ratings Contact ratings Operations SPDT, 4 VDC 4, 48 VAC/DC, 30 VAC 50 VAC 6 A (Resistive Load) 30 VDC 6 A (Resistive Load) 400 VAC A (Resistive Load) 50,000 50,000 6,000 Engineering Data Endurance Switching capacity of DC resistive load Endurance ( 3 operations) VDC inductive load (L/R=7ms) 30VDC resistive load 50VAC inductive load (cos ϕ = 0.4) 50VAC resistive load DC Breaking Current (A),0,0 0, Switching voltage (VDC) Switching current (A) Typical Operating and Release Time Model number Operating time (typical) Release time (typical) DC 5 ~ 7 ms 5 ~ 8 ms DC4 5 ~ 7 ms 6 ~ 9 ms AC/DC4 5 ~ 7 ms 7 ~ ms AC/DC48 5 ~ 7 ms ~ 30 ms AC ~ 5 ms ~ 30 ms AC30 ~ 5 ms ~ 30 ms 4 Slim Relay GRV

5 Accessories PLC Interface Contact form Relay PLC Interface Standard type series PRVC-8-O-F Input type GRV-SL700-AP series PRVC-8-I-F PRVC-8-O-F (for series only) Model number Description Connection PRVC-8-O-F PLC Output Interface for 8x PNP - type Ribbon cable connector Pole, IEC603/ Specifications Electrical schematic PRVC-8-O-F Input Rated voltage 30 VAC/VDC max. Current capacity 0.5 A per channel.0 A total current, power supply terminal Characteristics Ambient Operating: 0 to 55 C temperature Storage: 0 to 85 C Overvoltage III category Pollution degree PRVC-8-I-F (for GRV-SL700-AP series only) Model number Description Connection PRVC-8-I-F PLC Output Interface for 8x GRV-SL700-series PNP - type Ribbon cable connector Pole, IEC603/ Specifications Input Rated voltage 30 VAC/VDC max. Current capacity 0.5 A per channel.0 A total current, power supply terminal Characteristics Ambient Operating: 0 to 55 C temperature Storage: 0 to 85 C Overvoltage III category Pollution degree Electrical schematic PRVC-8-I-F Slim Relay GRV 5

6 Cables for PLC Interface Cables selection List Model number PRV-4-0C PRV-4-00C PRV-4-300C PRV-4-500C Cable to connect CJ to 4 Output To be used for (combined with PRVC-8-O-F) CJW-OD3/OD6 CJW-OD3/OD6 CJW-OD3/OD6 CJW-OD3/OD6 PRV-A0C Universal (stranded wires) PRV-00C Universal (stranded wires) PRV-A300C Universal (stranded wires) PRV-A500C Universal (stranded wires) PRV-A050C-OMR GRT GRT-OD8(G)- PRV-A0C-OMR GRT GRT-OD8(G)- PRV-A050C-OMR NX NX-OD456 PRV-A0C-OMR NX NX-OD456 PRV-00C-SIM S7/300 6ES7 3-BL00-0AA0, 3DO PRV-50C-SIM S7/300 6ES7 3-BL00-0AA0, 3DO PRV-300C-SIM S7/300 6ES7 3-BL00-0AA0, 3DO PRV-500C-SIM S7/300 6ES7 3-BL00-0AA0, 3DO PRV-00C-SIM S7/400 6ES74-BL00-0AA0 & 6ES74-7BL00-0AB0, 3DO PRV-50C-SIM S7/400 6ES74-BL00-0AA0 & 6ES74-7BL00-0AB0, 3DO PRV-300C-SIM S7/400 6ES74-BL00-0AA0 & 6ES74-7BL00-0AB0, 3DO PRV-500C-SIM S7/400 6ES74-BL00-0AA0 & 6ES74-7BL00-0AB0, 3DO Model number PRV-4-0IFC PRV-4-0IMC PRV-4-00IFC PRV-4-00IMC PRV-4-300IFC PRV-4-300IMC PRV-4-500IFC PRV-4-500IMC PRV-A0C PRV-00C PRV-A300C PRV-A500C PRV-A050IC-OMR GRT PRV-A0IC-OMR GRT PRV-A050IC-OMR NX PRV-A0IC-OMR NX PRV-00C-SIM S7/300 PRV-50C-SIM S7/300 PRV-300C-SIM S7/300 PRV-500C-SIM S7/300 PRV-00C-SIM S7/400 PRV-50C-SIM S7/400 PRV-300C-SIM S7/400 PRV-500C-SIM S7/400 I/O Model number Cable length Interface unit PLC Connection Connectors Output PRV-4-0C.0 m PRVC-8-O-F OMRON PLC MIL40 - MIL PRV-4-00C.0 m 4 CJ Series: MIL 4 PRV-4-300C 3.0 m PRV-4-500C 5.0 m Input PRV-4-0IMC.0 m PRVC-8-I-F OMRON PLC MIL40 - MIL PRV-4-00IMC.0 m 4 CJ Series: MIL 4 PRV-4-300IMC 3.0 m PRV-4-500IMC 5.0 m Input PRV-4-0IFC.0 m PRVC-8-I-F OMRON PLC FCN40 -MIL PRV-4-00IFC.0 m 4 CJ Series: 4 Fujitsu PRV-4-300IFC 3.0 m PRV-4-500IFC 5.0 m Input To be used for (combined with PRVC-8-I-F) CJW-ID3/ID33/ID6 CJW-ID33/ID6 CJW-ID3/ID33/ID6 CJW-ID33/ID6 CJW-ID3/ID33/ID6 CJW-ID33/ID6 CJW-ID3/ID33/ID6 CJW-ID33/ID6 Universal (stranded wires) Universal (stranded wires) Universal (stranded wires) Universal (stranded wires) GRT-ID8- GRT-ID8- NX-ID444 NX-ID444 6ES7 3-BL00-0AA0, 3DI 6ES7 3-BL00-0AA0, 3DI 6ES7 3-BL00-0AA0, 3DI 6ES7 3-BL00-0AA0, 3DI 6ES74-BL00-0AA0 & 6ES74-BL0-0AA0, 3DI 6ES74-BL00-0AA0 & 6ES74-BL0-0AA0, 3DI 6ES74-BL00-0AA0 & 6ES74-BL0-0AA0, 3DI 6ES74-BL00-0AA0 & 6ES74-BL0-0AA0, 3DI 9 CN 9 CN (45) Cable length as indicated by model number. = length in centimeters (300) CN CN CN3 CN CN CN3 CN4 B B0 0 (45) Cable length as indicated by model number. = length in centimeters (300) CN CN CN3 CN CN CN3 CN4 6 Slim Relay GRV

7 4 pole IDC mounting to 4 CN CN CN CN Pole Cable length as indictad by model number. = length in centimeters CN CN CN Split into 4 sections Length = 30 cm CN4 CN CN CN CN NC NC NC NC 3 CN CN CN CN A3 A4 A5 A6 A7 A8 NC A9 A NC 8 B B B3 B4 B5 B6 B7 B8 NC B9 B B B B3 B4 B5 B6 B7 NC B8 40 pole IDC mounting to Omron PLC CJ-OD3 Technical data Control line AWG8/0.08 mm, tin-plated copper Diameter cable.7 mm (one end splits into 4 sections: A, B, C, D) Operating voltage 60 VDC Continuous current per signal wire 0.5 A Max. total current, 4 bytes, each.0 A Test voltage 0.5 KV, 50 Hz, min Operating temperature range -0 C to +50 C Cable, single sided pole IDC connector, to connect to I/O Model number Cable length Interface unit PLC interface Connectors Universal PRV-A0C.0 m - MIL - (Output/ PRV-00C.0 m No connector Input) PRV-A300C 3.0 m PRV-A500C 5.0 m?r?p?x?v?t 9 (45) Cable length as indicated by model number. = length in centimeters (70) () () Slim Relay GRV 7

8 pole IDC mounting to GRAY / BLACK 9 GRAY / RED 8 ORANGE / BLACK 7 ORANGE / RED 6 GREEN / BLACK 5 GREEN / RED 4 PINK / BLACK 3 PINK / RED BLUE / BLACK BLUE / RED Technical data Open end Pole Cable length as indictad by model number. = length in centimeters Outer isolation removed Control line Diameter cable Operating voltage Continuous current per signal wire Max. total current Test voltage Operating temperature range AWG6/0.4 mm, tin-plated copper 7.6 mm 60 VDC 0.5 A.0 A 0.5 KV, 50 Hz, min -0 C to +50 C GRT GRT I/O Model number Cable length Output PRV-A050C-OMR GRT 0.5 m PRVC-8-O-F OMRON Smart slice I/O module PRV-A0C-OMR GRT.0 m Interface unit PLC interface Connectors GRT Series GRT-OD8(G)- Input PRV-A050IC-OMR GRT PRV-A0IC-OMR GRT 0.5 m.0 m PRVC-8-I-F OMRON Smart slice I/O module GRT Series GRT-ID9(G)- XW7E pole - MIL B?X?V?T?R?P 9 (45) Cable length as indicated by model number. = length in centimeters (45) B6 A6 pole IDC mounting to GRT GRT B6 B A6 3 3 B4 4 B 4 A4 5 A4 5 B3 6 B4 6 A3 7 A5 7 B 8 B5 8 9 NC 9 B B6 NC 8 Slim Relay GRV

9 ?R?P NX NX I/O Model number Cable length Interface unit PLC interface Connectors Output PRV-A050C-OMR GRT 0.5 m PRVC-8-O-F OMRON I/O XW7F 6pole- PRV-A0C-OMR GRT.0 m module NX MIL Series Input PRV-A050IC-OMR GRT 0.5 m PRVC-8-I-F PRV-A0IC-OMR GRT.0 m B?X?V?T 9 (45) Cable length as indicated by model number. = length in centimeters (45) B6 A6 pole IDC mounting to NX NX B7 B A7 3 A3 3 B5 4 B3 4 A5 5 A5 5 B3 6 B5 6 A3 7 A7 7 B 8 B7 8 9 NC 9 B8 B8 NC Cables to connect Siemens S7/300 or S7/400 to 4 Model number Cable length PLC type Configuration PRV-00C-SIM S7/300.0 m Siemens S7/300 4x Byte PRV-50C-SIM S7/300.5 m PRV-300C-SIM S7/300 PRV-500C-SIM S7/ m 5.0 m PRV-00C-SIM S7/400.0 m Siemens S7/400 4x Byte PRV-50C-SIM S7/400.5 m PRV-300C-SIM S7/400 PRV-500C-SIM S7/ m 5.0 m Slim Relay GRV 9

10 Single Relays for Maintenance Model Number Number of Poles : pole. Terminals S: Plug-In 3. Relay LED Blank: Without LED Model number Replacement for GRV--S VDC GRV-SL700/500 VDC GRV--S VDC GRV-SL700/500 4 VDC GRV-SL700/500 4 VAC/DC GRV--S 48 VDC GRV-SL700/ VAC/DC GRV-SL700/500 VAC GRV-SL700/ VAC GRV--S-AP VDC GRV-SL700/500-AP VDC GRV--S-AP VDC GRV-SL700/500-AP 4 VDC GRV-SL700/500-AP 4 VAC/DC GRV--S-AP 48 VDC GRV-SL700/500-AP 48 VAC/DC GRV-SL700/500-AP VAC GRV-SL700/500-AP 30 VAC GRV--SI VDC GRV-SL70/50 4 VDC GRV-SL70/50 4 VAC/DC 4. Relay Test switch Blank: No test switch I: Test switch 5. Contact Material Blank: AgSnIn AP: AgSnIn hard gold-plated 6. Rated Coil Voltage VDC, VDC, 48 VDC GRV--SI GRV--S Cross bars Model Number Legend Number of Poles. Color 00: poles R: Red 030: 3 poles S: Blue 040: 4 poles B: Black 0: poles 00: 0 poles Model number Poles Color 3 Red (R) 4 Blue (S) Black (B) select color: R = Red, S=Blue, B=Black Plastic Labels for GRV Sockets Specification Max current (EN section / 99) Max. Voltage Max. Voltage when cutting Cross-bar without using separation plate or end-bracket 3 A 400 VAC 50 VAC Model number Box quantity Color R99-5 for GRV piece = sheet = 0 labels White Slim Relay GRV

11 Labels (Stickers) for GRV Sockets Model number Box quantity Color R99-6 for GRV piece = sheet = 484 labels (stickers) White Separating Plates Model number PRV-S Description Provides isolation between adjacent relays to achieve 400 V isolation. Slim Relay GRV

12 Dimensions Note: All units are in millimeters unless otherwise indicated. Complete Unit GRV-SL700 GRV-SL700-AP Dimensions Terminal Arrangement Input circuit max max V DC max. 4 Other Coil Voltage Five, M V DC GRV-SL70 Dimensions Terminal Arrangement Input circuit max. 6. max V DC max. 4 Other Coil Voltage Five, M V DC Slim Relay GRV

13 GRV-SL500 GRV-SL500-AP Dimensions Terminal Arrangement 4 Input circuit 6.7 max. 6. max V DC max. 4 Other Coil Voltage V DC GRV-SL50 Dimensions Terminal Arrangement 4 Input circuit 9.7 max. 6. max V DC max. 4 Other Coil Voltage V DC Slim Relay GRV 3

14 Single Relay GRV--S GRV--S-AP 5. max max. 33 max. Input circuit 6. 4 (Bottom View) GRV--SI 5. max max. 36 max. Input circuit 4 6. (Bottom View) Slim Relay GRV

15 Installation Tools series: Flat-Blade screwdriver should be used for mounting and / or releasing cables. series: Flat-Blade screwdriver should be used for mounting stranded wires without ferrules and / or releasing cables. Applicable Screwdriver Flat-blade, Parallel-tip,.5 mm diameter (3.0 mm max.) Flat-blade, Parallel-tip.5 dia. (3.0 mm max.) Flat-blade, Flared-tip Cannot be used. Examples: FACOM AEF..5 75E (AEF. 3 75E) VESSEL No (-).5 75 (No (-)3 0) WAGO -9 WIHA 60/.5 40 (60/3 50) *Chamfering the tip of the driver improves insertion when used as an exclusive tool. PRVC-8-O-F (for series only) Model number Description Connection PRVC-8-O-F PLC Output Interface for 8x PNP - type Ribbon cable connector Pole, IEC603/ Applicable Wires Applicable Wire Sizes GRV-SL700 Series Box clamp technology Wire type Applicable wire size Stripping length Stranded without ferrules mm 7mm Stranded with ferrules and plastic collar mm 7mm Stranded with ferrules without plastic collar mm 7mm Solid mm 7mm GRV-SL500 Series Push-in technology Wire type Applicable wire size Stripping length Stranded without ferrules mm mm Stranded with ferrules and plastic collar mm mm Stranded with ferrules without plastic collar mm mm Solid mm mm Slim Relay GRV 5

16 Wiring Use wires of the applicable sizes specified above. The length of the exposed conductor should be 7 mm for a GRV-SL700 series, mm for a GRV-SL500 series. GRV-SL700 GRV-SL500 7 mm mm Fig. Exposed Conductor Length Wiring Procedure for GRV-SL500 series Screwdriver hole Wire connection hole Wiring Removing Wire Insert the exposed conductor into the connection hole. Insert the specified screwdriver into the release hole. No other tools are required. Removing wire. Note: In case of wiring stranded wires without ferrules screwdriver should be inserted before inserting the wire. Screwdriver should be removed after fully insertion of the wire. Removing screwdriver. 6 Slim Relay GRV

17 Precautions Precautions for Connection Do not move the screwdriver up, down, or from side to side while it is inserted in the hole. Doing so may cause damage to internal components (e.g., deformation of the clamp spring or cracks in the housing) or cause deterioration of insulation. Do not insert the screwdriver at an angle. Doing so may break the side of socket and result in a short-circuit. Do not pour water or cleansing agents on the product. Doing so may result in electric shock. Do not use the socket in locations subject to solvents or alkaline chemicals. Do not use the socket in locations subject to ultraviolet light (e.g., direct sunlight). Doing so may result in markings fading, rust, corrosion, or resin deterioration. Do not dispose the product in fire. Removing from Mounting Rail To remove the socket from the mounting rail, insert the tip of screwdriver in the fixture rail, and move it in the direction shown below. Do not insert two or more wires in the hole. Wires may come in contact with the spring causing a temperature rise or be subject to sparks. Precaution for Operation of Test switch Insert the screwdriver along the hole wall as shown below. Tool: GRV-SL70/50 series:.5 mm width Flat-Blade screwdriver should be used for operation of test switch. Flat-blade, Parallel-tip,.5 mm diameter (3.0 mm max.) Flat-blade, Parallel-tip Screwdriver If lubricating liquid, such as oil, is present on the tip of screwdriver, the screwdriver may fall out resulting in injury to the operator. Insert the screwdriver into the bottom of the hole. It may not be possible to connect cables properly if the screwdriver is inserted incorrectly. General Precautions Do not use the product if it has been dropped on the ground. Dropping the product may adversely affect performance. Confirm that the socket is securely attached to the mounting track before wiring. If the socket is mounted insecurely it may fall and injure the operator. Ensure that the socket is not charged during wiring and maintenance. Not doing so may result in electric shock..5 dia. (3.0 mm max.) Flat-blade, Flared-tip Cannot be used. Cautions: When you operate a test switch, please turn off electrical power supply. After you have finished to operate a test switch, return the test switch to its original state Do not use test switch as a switch. Durability of test switch operation is more than 0 times. Please avoid to use the latching lever by ON state with carry current in long time, more than 4 hours to maintain the initial performance for operation checking. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by To convert grams into ounces, multiply by Cat. No. JE-EN-06 In the interest of product improvement, specifications are subject to change without notice. Slim Relay GRV 7

18 Terms and Conditions of Sale. Offer; Acceptance. These terms and conditions (these "Terms") are deemed part of all quotes, agreements, purchase orders, acknowledgments, price lists, catalogs, manuals, brochures and other documents, whether electronic or in writing, relating to the sale of products or services (collectively, the "Products") by Omron Electronics LLC and its subsidiary companies ( Omron ). Omron objects to any terms or conditions proposed in Buyer s purchase order or other documents which are inconsistent with, or in addition to, these Terms.. Prices; Payment Terms. All prices stated are current, subject to change without notice by Omron. Omron reserves the right to increase or decrease prices on any unshipped portions of outstanding orders. Payments for Products are due net 30 days unless otherwise stated in the invoice. 3. Discounts. Cash discounts, if any, will apply only on the net amount of invoices sent to Buyer after deducting transportation charges, taxes and duties, and will be allowed only if (i) the invoice is paid according to Omron s payment terms and (ii) Buyer has no past due amounts. 4. Interest. Omron, at its option, may charge Buyer -/% interest per month or the maximum legal rate, whichever is less, on any balance not paid within the stated terms. 5. Orders. Omron will accept no order less than $00 net billing. 6. Governmental Approvals. Buyer shall be responsible for, and shall bear all costs involved in, obtaining any government approvals required for the importation or sale of the Products. 7. Taxes. All taxes, duties and other governmental charges (other than general real property and income taxes), including any interest or penalties thereon, imposed directly or indirectly on Omron or required to be collected directly or indirectly by Omron for the manufacture, production, sale, delivery, importation, consumption or use of the Products sold hereunder (including customs duties and sales, excise, use, turnover and license taxes) shall be charged to and remitted by Buyer to Omron. 8. Financial. If the financial position of Buyer at any time becomes unsatisfactory to Omron, Omron reserves the right to stop shipments or require satisfactory security or payment in advance. If Buyer fails to make payment or otherwise comply with these Terms or any related agreement, Omron may (without liability and in addition to other remedies) cancel any unshipped portion of Products sold hereunder and stop any Products in transit until Buyer pays all amounts, including amounts payable hereunder, whether or not then due, which are owing to it by Buyer. Buyer shall in any event remain liable for all unpaid accounts. 9. Cancellation; Etc. Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Omron against all related costs or expenses.. Force Majeure. Omron shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority.. Shipping; Delivery. Unless otherwise expressly agreed in writing by Omron: a. Shipments shall be by a carrier selected by Omron; Omron will not drop ship except in break down situations. b. Such carrier shall act as the agent of Buyer and delivery to such carrier shall constitute delivery to Buyer; c. All sales and shipments of Products shall be FOB shipping point (unless otherwise stated in writing by Omron), at which point title and risk of loss shall pass from Omron to Buyer; provided that Omron shall retain a security interest in the Products until the full purchase price is paid; d. Delivery and shipping dates are estimates only; and e. Omron will package Products as it deems proper for protection against normal handling and extra charges apply to special conditions.. Claims. Any claim by Buyer against Omron for shortage or damage to the Products occurring before delivery to the carrier must be presented in writing to Omron within 30 days of receipt of shipment and include the original transportation bill signed by the carrier noting that the carrier received the Products from Omron in the condition claimed. 3. Warranties. (a) Exclusive Warranty. Omron s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABIL- ITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron s sole obligation hereunder shall be, at Omron s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See or contact your Omron representative for published information. 4. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. 5. Indemnities. Buyer shall indemnify and hold harmless Omron Companies and their employees from and against all liabilities, losses, claims, costs and expenses (including attorney's fees and expenses) related to any claim, investigation, litigation or proceeding (whether or not Omron is a party) which arises or is alleged to arise from Buyer's acts or omissions under these Terms or in any way with respect to the Products. Without limiting the foregoing, Buyer (at its own expense) shall indemnify and hold harmless Omron and defend or settle any action brought against such Companies to the extent based on a claim that any Product made to Buyer specifications infringed intellectual property rights of another party. 6. Property; Confidentiality. Any intellectual property in the Products is the exclusive property of Omron Companies and Buyer shall not attempt to duplicate it in any way without the written permission of Omron. Notwithstanding any charges to Buyer for engineering or tooling, all engineering and tooling shall remain the exclusive property of Omron. All information and materials supplied by Omron to Buyer relating to the Products are confidential and proprietary, and Buyer shall limit distribution thereof to its trusted employees and strictly prevent disclosure to any third party. 7. Export Controls. Buyer shall comply with all applicable laws, regulations and licenses regarding (i) export of products or information; (iii) sale of products to forbidden or other proscribed persons; and (ii) disclosure to non-citizens of regulated technology or information. 8. Miscellaneous. (a) Waiver. No failure or delay by Omron in exercising any right and no course of dealing between Buyer and Omron shall operate as a waiver of rights by Omron. (b) Assignment. Buyer may not assign its rights hereunder without Omron's written consent. (c) Law. These Terms are governed by the law of the jurisdiction of the home office of the Omron company from which Buyer is purchasing the Products (without regard to conflict of law principles). (d) Amendment. These Terms constitute the entire agreement between Buyer and Omron relating to the Products, and no provision may be changed or waived unless in writing signed by the parties. (e) Severability. If any provision hereof is rendered ineffective or invalid, such provision shall not invalidate any other provision. (f) Setoff. Buyer shall have no right to set off any amounts against the amount owing in respect of this invoice. (g) Definitions. As used herein, including means including without limitation ; and Omron Companies (or similar words) mean Omron Corporation and any direct or indirect subsidiary or affiliate thereof. Certain Precautions on Specifications and Use. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer s application or use of the Product. At Buyer s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer s application, product or system. Buyer shall take application responsibility in all cases but the following is a non-exhaustive list of applications for which particular attention must be given: (i) Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document. (ii) Use in consumer products or any use in significant quantities. (iii) Energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. (iv) Systems, machines and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to this Product. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON S PRODUCT IS PROP- ERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.. Programmable Products. Omron Companies shall not be responsible for the user s programming of a programmable Product, or any consequence thereof. 3. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron s Warranty and Limitations of Liability. 4. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron s representative at any time to confirm actual specifications of purchased Product. 5. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions.

19 OMRON AUTOMATION AND SAFETY THE AMERICAS HEADQUARTERS Chicago, IL USA OMRON CANADA, INC. HEAD OFFICE Toronto, ON, Canada OMRON ELECTRONICS DE MEXICO HEAD OFFICE México DF OMRON ELECTRONICS DE MEXICO SALES OFFICE Apodaca, N.L OMRON ARGENTINA SALES OFFICE Cono Sur OMRON CHILE SALES OFFICE Santiago OTHER OMRON LATIN AMERICA SALES OMRON ELETRÔNICA DO BRASIL LTDA HEAD OFFICE São Paulo, SP, Brasil OMRON EUROPE B.V. Wegalaan 67-69, NL-3 JD, Hoofddorp, The Netherlands. +3 (0) Authorized Distributor: Automation Control Systems Machine Automation Controllers (MAC) Programmable Controllers (PLC) Operator interfaces (HMI) Distributed I/O Software Drives & Motion Controls Servo & AC Drives Motion Controllers & Encoders Temperature & Process Controllers Single and Multi-loop Controllers Sensors & Vision Proximity Sensors Photoelectric Sensors Fiber-Optic Sensors Amplified Photomicrosensors Measurement Sensors Ultrasonic Sensors Vision Sensors Industrial Components RFID/Code Readers Relays Pushbuttons & Indicators Limit and Basic Switches Timers Counters Metering Devices Power Supplies Safety Laser Scanners Safety Mats Edges and Bumpers Programmable Safety Controllers Light Curtains Safety Relays Safety Interlock Switches J46I-E-0 06/4 Note: Specifications are subject to change. 04 Omron Electronics LLC Printed in U.S.A. Printed on recycled paper.

Slim Relay G2RV. Features. Test switch operation. Protection cover: lock. Protection cover: unlock. Protection cover open. Protection cover close

Slim Relay G2RV. Features. Test switch operation. Protection cover: lock. Protection cover: unlock. Protection cover open. Protection cover close Slim Relay GRV The only truly industrial 6 mm relay Lockable test switch models now available. Large plug-in terminals for reliable connection. LED indicator and mechanical flag for status indication.

More information

General-purpose Relays

General-purpose Relays General-purpose Relays MK-S New Model General-purpose Relays Featuring Mechanical Indicator and Lockable Test Button Built-in operation indicator (mechanical and LED), and new models with lockable test

More information

Socket P2RF-05-S P2RF-08-S Clip & Release Lever R99-11 nameplate for MY

Socket P2RF-05-S P2RF-08-S Clip & Release Lever R99-11 nameplate for MY Screwless Clamp Terminal Socket Screwless clamping greatly contributes to reducing wiring time. No over or under tightening of cable connection so better contact reliability is achieved. Double wiring

More information

E2K-L. Liquid Level Sensor. Applications. Ordering Information. E-68 Proximity Sensors

E2K-L. Liquid Level Sensor. Applications. Ordering Information. E-68 Proximity Sensors Liquid Level Sensor Installation on pipes. Sensing by means electrostatic capacity and is not influenced by the color of the pipe or liquid. Available in 8 to mm dia. and to mm dia. models to enable sensing

More information

CQM1-SF200/CS1W-SF200

CQM1-SF200/CS1W-SF200 Safety Relay Unit ( I/O Unit Type) CQM1-SF200/CS1W-SF200 CSM_CQM1-SF200_CS1W-SF200_DS_E_2_1 A Safety Relay Unit That Functions as a I/O Unit. Less Installation Space and Wiring Required. Safety Relay Unit

More information

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information. Wafer-carrier Mounting Photomicrosensors EE-SPY1/ CSM_EE-SPY1 DS_E_3_ Photomicrosensors for detecting wafer-carrier mounting. The mounting position is set with a pedestal. The contact surface with the

More information

Type Terminal Coil Contact form Model

Type Terminal Coil Contact form Model General Purpose Relay MK Exceptionally reliable general purpose relay. Long life (minimum 100,000 electrical operations) assured by silver contacts. Built-in operation indicator (mechanical, LED), diode

More information

VAQ. Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment. Pushbutton Switch (Cylindrical 10.5-dia.

VAQ. Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment. Pushbutton Switch (Cylindrical 10.5-dia. Pushbutton Switch (Cylindrical 10.5-dia.) CSM DS_E_4_4 Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment Momentary operation and lock. available in six colors.

More information

Photoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units)

Photoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units) Photoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units) E3C-LDA Series All three beam types provide ample long-distance detection of 1,000 mm for Diffuse Reflective Models.

More information

CX-One Ver.4. FA Integrated Tool Package CX-One. Greater Integration with the CX-One. Features

CX-One Ver.4. FA Integrated Tool Package CX-One. Greater Integration with the CX-One. Features FA Integrated Tool Package CX-One CX-One Ver.4 CSM_CX-One_DS_E_3_1 Greater Integration with the CX-One The CX-One is a comprehensive software package that integrates PLC Programming Software with Support

More information

Model Number Structure

Model Number Structure General-purpose Relay G2RS Slim and Space-saving Power Plug-in Relay Lockable test button models now available. Built-in mechanical operation indicator. Provided with nameplate. AC type is equipped with

More information

Ordering Information. Latching Relay G2AK. Model Number Legend G2AK-@@@@@ 1 2 3 4 5. Magnetic Latching Version of G2A Ideal for Sequence Control

Ordering Information. Latching Relay G2AK. Model Number Legend G2AK-@@@@@ 1 2 3 4 5. Magnetic Latching Version of G2A Ideal for Sequence Control Latching Relay CSM DS_E_4_1 Magnetic Latching Version of G2A Ideal for Sequence Control Double-winding latch system with continuous rating. Terminals pulled from the respective junctions between the built-in

More information

Model Number Structure

Model Number Structure General-purpose Relay G2RS Slim and Space-saving Power Plug-in Relay Lockable test button models now available. Built-in mechanical operation indicator. Provided with nameplate. AC type is equipped with

More information

Tab (#110) terminal Actuator

Tab (#110) terminal Actuator Snap Action Switch SS Subminiature Snap Action Switch Economical, subminiature snap action switch offers long service life (30 million operations minimum) All models are free from overtravel restrictions,

More information

Advantium 2 Plus Alarm

Advantium 2 Plus Alarm ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia

More information

SELLING TERMS AND CONDITIONS

SELLING TERMS AND CONDITIONS SELLING TERMS AND CONDITIONS 1. The Agreement. All sales by Sterling Machinery, Inc., an Arkansas corporation (the Seller ) to the purchaser of Seller s Goods (the Buyer ) shall be governed by the following

More information

G6K-2F G6K-2F-Y G6KU-2F-Y

G6K-2F G6K-2F-Y G6KU-2F-Y Low Signal Relay G6K Fourth generation design. Design based on worldwide communications, computer peripheral and office automation relay requirements. Offers excellent board space savings. Meets 2.5 kv

More information

E2K-L. Liquid Level Sensor. Applications. Ordering Information

E2K-L. Liquid Level Sensor. Applications. Ordering Information Liquid Level Sensor Installation on pipes. Sensing by means electrostatic capacity and is not influenced by the color of the pipe or liquid. Available in 8 to mm dia. and to mm dia. models to enable sensing

More information

E3T Miniature Photoelectric Sensors

E3T Miniature Photoelectric Sensors E3T Miniature Photoelectric Sensors Ultra-Compact with Visible Red Beam»» Ultra slim to fit and perform where others won't»» Visible red beam for simple set-up»» Five different sensing methods E3T Miniature

More information

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws Compact Pre-wired Photomicrosensor with Built-in Amplifier (Non-modulated) CSM DS_E_7_2 Meeting Customer Needs with Compact Sensors that Mount with M Screws Both light-on and dark-on outputs provided.

More information

Slim Relay G3RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

Slim Relay G3RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations Slim Relay G3RV The World's First Industrial Slim Relay G2RV compatible LED indicator built in SSR Push-in terminals and accessories for easy wiring. Model Number Structure Model Number Legend G3RV-SL

More information

PCB Relay. LED indicator G2R-1A3-SN G2R-13-SN --- --- contact) LED indicator and diode DC G2R-1A3-SND G2R-13-SND --- ---

PCB Relay. LED indicator G2R-1A3-SN G2R-13-SN --- --- contact) LED indicator and diode DC G2R-1A3-SND G2R-13-SND --- --- PCB Relay A Power Relay for a Variety of Purposes with Various Models Conforms to VDE045 (VDE approval: C2 insulation grade), UL8, CSA22.2, SEV, SEMKO. Meets VDE0700 requirements for household products

More information

SPST-NO SPDT DPST-NO DPDT

SPST-NO SPDT DPST-NO DPDT PCB Relay Next-generation PCB Relay Available in 2 Models Low profile:. mm max. in height Contains no lead inside and features cadmium-free contacts ensuring environment-friendly use. Conforms to VDE0

More information

Number of poles 1-pole 2-pole Minimum Enclosure Contact. G2R-1AZ G2R-1Z DC Fully sealed G2R-1AZ4 G2R-1Z4 G2R-1A-E G2R-1-E

Number of poles 1-pole 2-pole Minimum Enclosure Contact. G2R-1AZ G2R-1Z DC Fully sealed G2R-1AZ4 G2R-1Z4 G2R-1A-E G2R-1-E PCB Power elay The Best Seller eneral purpose power elays of single-pole0 A and double-pole A. Safety-oriented design with dielectric strength of,000 V between coil and contacts, and surge resistance of

More information

PDQ Workholding LLC Terms and Conditions of Sale

PDQ Workholding LLC Terms and Conditions of Sale PDQ Workholding LLC Terms and Conditions of Sale Unless otherwise specifically stated in the offer to sell goods submitted herewith ( Sales Quotation ), these Terms and Conditions establish the rights,

More information

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils

More information

Standard with LED indicator

Standard with LED indicator General-purpose Relay MY Versatile, Multi-featured, Miniature Power Relay for Sequence Control and Power Switching Applications Models with lockable test buttons now available. Multiple features available,

More information

SPST-NO SPDT DPST-NO DPDT

SPST-NO SPDT DPST-NO DPDT PCB Relay A Power Relay for a Variety of Purposes with Various Models Conforms to VDE (EN680-), UL08, CSA22.2. Meets EN6033- requirements for household products. Clearance and creepage distance: 8 mm/8

More information

Terms and Conditions. 3012436v2 12285.01010

Terms and Conditions. 3012436v2 12285.01010 Terms and Conditions ACCEPTANCE. Except as otherwise agreed in a written agreement signed by both parties, these Terms and Conditions will govern Buyer s purchase order. BI Technologies acceptance of Buyer

More information

G7SA. Ordering Information. Slim Plug-In Safety Relay. Slim Safety Relay for Machine Control. H Slim body only 13 x 24 x 50 mm

G7SA. Ordering Information. Slim Plug-In Safety Relay. Slim Safety Relay for Machine Control. H Slim body only 13 x 24 x 50 mm Slim Plug-In Safety Relay Slim Safety Relay for Machine Control H Slim body only 13 x 24 x 50 mm (six poles) H Four-pole and six-pole models are available H Terminal arrangement simplifies PCB pattern

More information

Type Sealing Poles Contacts Rated voltage Model Standard d Flux-tight 4 poles oes 3PST-NO, SPST-NC 24 VDC G7SA-3A1B 3PST-NO, 3PST-NC

Type Sealing Poles Contacts Rated voltage Model Standard d Flux-tight 4 poles oes 3PST-NO, SPST-NC 24 VDC G7SA-3A1B 3PST-NO, 3PST-NC Safety Relay Slim Safety Relays Conforming to EN Standards The forcibly guided contact in the assures safe operation (EN50205 Class A, approved by VDE.) Ideal for use in safety circuits in press machinery,

More information

Appearance Type Setting distance Sensing area Model Remarks Camera with lighting. 34mm to 49mm 5mm x 4.9mm to 9mm x 8.

Appearance Type Setting distance Sensing area Model Remarks Camera with lighting. 34mm to 49mm 5mm x 4.9mm to 9mm x 8. ZFX-C10/15-CD Easy Vision Touch, Connect & Go Easy vision intuitive teach & go user interfaces Live built-in LCD touch monitors for setup and iediate feedback Counication centralized setup & inspection

More information

HL-5000. Economical, Miniature Limit Switch Boasting Rigid Construction. General-purpose Limit Switch. Model Number Structure.

HL-5000. Economical, Miniature Limit Switch Boasting Rigid Construction. General-purpose Limit Switch. Model Number Structure. General-purpose Limit Switch CSM DS_E_3_ Economical, Miniature Limit Switch Boasting Rigid Construction The Head, Box, and Cover mate with ridged surfaces to maintain strength. A unique Head structure

More information

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0. 48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according

More information

Standard Terms & Conditions of Quotation and Sale

Standard Terms & Conditions of Quotation and Sale S E N S A T A T E C H N O L O G I E S, I N C. Standard Terms & Conditions of Quotation and Sale TERMS & CONDITIONS OF QUOTATION BUYER S OFFER RESULTING FROM SELLER S QUOTATION IS EXPRESSLY CONDITIONED

More information

RY2 miniature industrial relays

RY2 miniature industrial relays 6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,

More information

Original instructions Tina 3A/Aps Adaptor unit

Original instructions Tina 3A/Aps Adaptor unit Original instructions Tina 3A/Aps Adaptor unit ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this

More information

1 POLE 5 A (CADMIUM FREE CONTACTS TYPE) NY SERIES

1 POLE 5 A (CADMIUM FREE CONTACTS TYPE) NY SERIES POWER RELAY 1 POLE 5 A (CADMIUM FREE CONTACTS TYPE) NY SERIES RoHS compliant FEATURES Ultra slim type with 5 mm thickness Good for high density mounting Low power consumption and high sensitivity Nominal

More information

DATA SHEET COMPACT AND LIGHTWEIGHT, SMALL MOUNTING SIZE, HIGH BREAKDOWN VOLTAGE

DATA SHEET COMPACT AND LIGHTWEIGHT, SMALL MOUNTING SIZE, HIGH BREAKDOWN VOLTAGE DATA SHEET MINIATURE SIGNAL RELAY EC SERIES COMPACT AND LIGHTWEIGHT, SMALL MOUNTING SIZE, HIGH BREAKDOWN VOLTAGE DESCRIPTI The EC series has reduced mounting space but sustained high-performance of NEC

More information

NJ SQL Best Practices

NJ SQL Best Practices NJ SQL Best Practices Johnston Hall March 13 th, 2015 NJ SQL Best Practices V1.0 Contents Disclaimer... 3 Summary... 3 The purpose of this paper... 3 The Basics... 3 SQL Setup... 3 NJ Setup... 3 Writing

More information

Liquid Leakage Sensor Amplifier

Liquid Leakage Sensor Amplifier 9 Liquid Leakage Sensor Amplifier Space-saving Sensor Amplifier reliably detects a wide variety of liquids ranging from water to chemical liquids with low conductivity 1 Detects leakage of liquid such

More information

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles Clear Glass Sensor Optimum Sensor for Detecting Transparent Glass and Plastic Bottles E3S-CR67/62 Retroreflective Sensor smoothly detects 5-mm gaps. Detects transparent bottles that have a lens effect.

More information

48 SERIES Relay interface modules 10 A

48 SERIES Relay interface modules 10 A 48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply

More information

XG2. Flat Cable Connectors for PCBs. Achieve Total Cost Reduction through High-density Mounting and Reduced Wiring. Terminal Arrangement

XG2. Flat Cable Connectors for PCBs. Achieve Total Cost Reduction through High-density Mounting and Reduced Wiring. Terminal Arrangement Flat Cable Connectors for PCBs XG2 Achieve Total Cost Reduction through High-density Mounting and Reduced Wiring IDC connections allow you to wire all terminals at once without terminating the cable. Can

More information

Resolution (divisions) Pre-wired Model E6F-AB3C 360P/R 2M *2 Pre-wired Connector E6F-AB3C-C 360P/R 2M *2 Model (2 m) NPN open collector BCD 360

Resolution (divisions) Pre-wired Model E6F-AB3C 360P/R 2M *2 Pre-wired Connector E6F-AB3C-C 360P/R 2M *2 Model (2 m) NPN open collector BCD 360 Absolute 60-mm-dia. Rotary Encoder CSM DS_E_7_ Rugged Rotary Encoder Absolute model. External diameter of 60 mm. Resolution of up to 1,024 (10-bit). IP65 oil-proof protection. Strong shaft. Radial: 120

More information

NX safety stand-alone

NX safety stand-alone NX-S@ NX safety stand-alone stand-alone into machine automation Expandable safety system up to 32 safety connections or 63 standard connections controller flexible system lets your freely mix safety I/O

More information

Safety Manual BT50(T) Safety relay / Expansion relay

Safety Manual BT50(T) Safety relay / Expansion relay Safety Manual BT50(T) Safety relay / Expansion relay ABB Jokab Safety Varlabergsvägen 11, SE-434 39, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this document

More information

Infineon Technologies North America Corp. Terms and Conditions of Sale

Infineon Technologies North America Corp. Terms and Conditions of Sale Infineon Technologies North America Corp. Terms and Conditions of Sale 1. GENERAL 1.1 Contract Terms. These Terms and Conditions of Sale (the Agreement ) shall apply to any offer made by Infineon Technologies

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical

More information

Surface Mounting Relay

Surface Mounting Relay Surface Mounting Relay Surface Mounting Relay with the World s Smallest Mounting Area and a Height of Only 5.2 mm Subminiature model as small as 5.2 (H) x 6.5 (W) x 10 (L) mm is ideal for high-density

More information

E2FM. Inductive Proximity Sensor in full metal housing. Application. Continuous Impact Test. Brush Test

E2FM. Inductive Proximity Sensor in full metal housing. Application. Continuous Impact Test. Brush Test Inductive Proximity Sensor in full metal housing Full body stainless steel housing for highest mechanical protection Low frequency modulation for metal chip immunity Flame retardant cable for high protection

More information

Tina 2A/B Adaptor unit

Tina 2A/B Adaptor unit Original instructions Tina 2A/B Adaptor unit ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this

More information

Phase-sequence Phase-loss Relay

Phase-sequence Phase-loss Relay New Product Phase-sequence Phase-loss Relay K8DS-PH Three-phase Phase-sequence Phase-loss Relay Using Voltage Detection Method Lineup includes a 17.5-mm slim, compact model. Greater resistance to inverter

More information

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual. i800 AC Current Clamp Instruction Sheet Introduction The i800 AC Current Clamp, the Clamp, has been designed for use with multimeters, recorders, power analyzers, safety testers, etc., for accurate non-intrusive

More information

Print mark detection photoelectric sensor in compact stainless steel housing

Print mark detection photoelectric sensor in compact stainless steel housing Print mark detection photoelectric sensor in compact stainless steel housing The detergent resistant photoelectric sensor in a robust stainless steel housing provides reliable detection of all common print

More information

PURCHASE ORDER ACKNOWLEGMENT AND TERMS AND CONDITIONS

PURCHASE ORDER ACKNOWLEGMENT AND TERMS AND CONDITIONS PURCHASE ORDER ACKNOWLEGMENT AND TERMS AND CONDITIONS 1. REJECTION OF ORDERS WITH CONTRADICTORY TERMS-All orders submitted by a buyer are subject to approval by an officer or other authorized official

More information

Safety technique. Emergency stop module BO 5988 safemaster

Safety technique. Emergency stop module BO 5988 safemaster Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1

More information

TERMS AND CONDITIONS

TERMS AND CONDITIONS TERMS AND CONDITIONS 1. Definitions. Buyer means the person, corporation or other entity purchasing Products from Seller. Products means all goods and materials to be provided pursuant to this Sales Acknowledgment.

More information

Maintenance information. DRT2-series. Remote I/O Terminals Relay Output Terminals. DRT2-series. DRT2-series Smart Slave Analog I/O Terminals

Maintenance information. DRT2-series. Remote I/O Terminals Relay Output Terminals. DRT2-series. DRT2-series Smart Slave Analog I/O Terminals CS-series Net Unit CSM DS_E_5_1 A Net Unit for the CS Series That Boasts Industry-leading Performance and Functions Features Allows control of up to 32,000 points (2,000 words) per master, and ensures

More information

COMPLIANCE WITH LAWS, CODES, AND STANDARDS

COMPLIANCE WITH LAWS, CODES, AND STANDARDS All products furnished by Jinan Meide Casting Co. Ltd, shall be in accordance with the following terms and conditions unless otherwise agreed to in writing: ACCEPTANCE AND COMPLETE AGREEMENT Buyer s order

More information

i410/i1010 AC/DC Current Clamp

i410/i1010 AC/DC Current Clamp /i1010 AC/DC Current Clamp Instruction Sheet Safety Information XW Read First: Safety Information To ensure safe operation and service of the current clamp, follow these instructions: Read all operating

More information

1 POLE - 16A 80A Inrush type. (b) Contact configuration A : 1 form A (SPST-NO) C : 1 form C (SPDT) (standard type "K" only)

1 POLE - 16A 80A Inrush type. (b) Contact configuration A : 1 form A (SPST-NO) C : 1 form C (SPDT) (standard type K only) FTR-K1 SERIES POWER RELAY 1 POLE - 16A 80A Inrush type FTR-K1 Series FEATURES Peak 80A inrush current (1 form A type) Low profile (height: 15.7mm) HIGH INSULATION Insulation distance (between coil and

More information

GENERAL CABLE COMPANY LTD. TERMS AND CONDITIONS OF SALE (Canada)

GENERAL CABLE COMPANY LTD. TERMS AND CONDITIONS OF SALE (Canada) GENERAL CABLE COMPANY LTD. TERMS AND CONDITIONS OF SALE (Canada) 1. ACCEPTANCE. This is an offer for General Cable Company Ltd. ( Seller ) to sell the product(s) ( Goods ) offered by it to the party to

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays

More information

49 Series - Relay interface modules 8-10 - 16 A. Features

49 Series - Relay interface modules 8-10 - 16 A. Features Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole

More information

1 POLE - 5A SLIM POWER RELAY

1 POLE - 5A SLIM POWER RELAY POWER RELAY POLE - A SLIM POWER RELAY FTR-MY Series RoHS compliant FEATURES Width mm, height mm,(% smaller than NY series) area mm, super slim, low power, compact and light weight.gr. Nominal power: mw

More information

Type Contact material Contact form Construction Model General purpose AgCdO SPDT Semi-sealed G2R-1

Type Contact material Contact form Construction Model General purpose AgCdO SPDT Semi-sealed G2R-1 Power PCB Relay G2R Creepage distance of 8.0 mm (0.31) min. between coil and contact. Dual-winding latching type available. Plug-in and quick-connect terminals available. High sensitivity (360 mw) and

More information

CM Series. Most Diverse and Flexible Line of Coded Magnetic Safety Interlock Switches and Controllers. Description. Safety Interlock Switches

CM Series. Most Diverse and Flexible Line of Coded Magnetic Safety Interlock Switches and Controllers. Description. Safety Interlock Switches R Safety Interlock Switches CM Series Most Diverse and Flexible Line of Coded Magnetic Safety Interlock Switches and Controllers Combine door switch monitoring and E-stop monitoring by using the CM-S41

More information

Solid-State Timer H3G

Solid-State Timer H3G ASH & ALAIN INDIA PVT LTD S-100, F.I.E.E., Okhla Industrial Area, Phase-ii, New Delhi-11000(India) Tel : 011-43797575 Fax : 011-43797574 E-mail : sales@ashalain.com Solid-State Timer Low-Cost, Plug-In

More information

MasterINTERFACE 39 Series - Relay interface modules

MasterINTERFACE 39 Series - Relay interface modules MasterINTERFACE 39 Series - 39 Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy ejection by plastic

More information

Smile 11 AS-i Emergency stop with safe AS-i input node

Smile 11 AS-i Emergency stop with safe AS-i input node Original instructions Smile 11 AS-i Emergency stop with safe AS-i input node SAFETY AT WORK ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand

More information

General Terms and Conditions of Sale and Delivery BruggemannChemical U.S., Inc. Date: January 1, 2012. I. General

General Terms and Conditions of Sale and Delivery BruggemannChemical U.S., Inc. Date: January 1, 2012. I. General General Terms and Conditions of Sale and Delivery BruggemannChemical U.S., Inc. Date: January 1, 2012 I. General 1.1 The following general terms and conditions of sale and delivery (hereinafter General

More information

DATA DETECTION TECHNOLOGIES LTD ("DATA") Terms and Conditions to Integrator Agreement

DATA DETECTION TECHNOLOGIES LTD (DATA) Terms and Conditions to Integrator Agreement DATA DETECTION TECHNOLOGIES LTD ("DATA") Terms and Conditions to Integrator Agreement These DATA Terms and Conditions (the "Integrator Terms and Conditions") govern all and any transactions by which any

More information

TERMS AND CONDITIONS OF SALE. Quotations, Purchase Orders, Acknowledgements, Packing Lists/Slips, Invoices & Credits

TERMS AND CONDITIONS OF SALE. Quotations, Purchase Orders, Acknowledgements, Packing Lists/Slips, Invoices & Credits Quotations, Purchase Orders, Acknowledgements, Packing Lists/Slips, Invoices & Credits All quotations of Seller ( Quotations ) and purchase orders of Buyer ( Purchase Orders ) shall be subject to these

More information

Proximity Sensor with All-stainless Housing

Proximity Sensor with All-stainless Housing NEW Proximity Sensor with All-stainless Housing Highly Durable Proximity Sensor for Tough Environments One-piece completely stainless-steel housing with a face thickness of.8 mm! The face thickness is

More information

Triton Systems of Delaware, LLC. Warranty Statement

Triton Systems of Delaware, LLC. Warranty Statement Triton Systems of Delaware, LLC 21405 B Street 866.7.TRITON Triton Systems of Delaware, LLC Warranty Statement TRITON WARRANTY STATEMENT The Manufacturer warrants that the products delivered to a distributor

More information

Evoqua Water Technologies LLC. ( Evoqua )

Evoqua Water Technologies LLC. ( Evoqua ) Evoqua Water Technologies LLC. ( Evoqua ) Remote Monitoring Services Terms and Conditions of Use These terms and conditions govern the use of Evoqua Link2Site sm Remote Monitoring Services whether the

More information

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2 Cylindrical Sensor E2E/E2E2 A New Series of Easy-to-use and Tough E2E/E2E2 Models Long-size E2E2 Sensor Conforms to CENELEC Ideal for a variety of applications. With a metal connector that can be tightened

More information

D2SW-P. Sealed Subminiature Basic Switch. Ordering Information

D2SW-P. Sealed Subminiature Basic Switch. Ordering Information Sealed Subminiature Basic Switch Sealed Basic Switch with Simplified Construction, Mounting Compatible with SS and D2SW Series. Sealing by using rubber packing means the switch can be used in dust-proof

More information

SolarEdge Technologies Ltd.

SolarEdge Technologies Ltd. SolarEdge Technologies Ltd. GENERAL TERMS AND CONDITIONS 1. General. This document, entitled General Terms and Conditions (referred to herein as the Agreement ), forms an integral part of the quotation

More information

DISCONTINUED (1998) FBR46 SERIES. MINIATURE RELAY 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) RoHS compliant FEATURES

DISCONTINUED (1998) FBR46 SERIES. MINIATURE RELAY 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) RoHS compliant FEATURES MINIATURE RELAY 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) FBR46 SERIES RoHS compliant FEATURES Miniature size About 50% smaller in volume compared with the FBR240 series used mainly in communication equipment.

More information

Color Mark Sensor with Red or Green LED E3S-VS

Color Mark Sensor with Red or Green LED E3S-VS Color Mark Sensor with Red or Green LED Rugged IP67 Color Mark Sensor 1 ms response time Detects a wide variety of color marks PNP or NPN output ls Light-on/ Dark-on operation, wire selectable Vertical

More information

This AGREEMENT is made as of the day of in the year of, by and between the following parties, for the sale of materials.

This AGREEMENT is made as of the day of in the year of, by and between the following parties, for the sale of materials. MCPU Standard Contract 101 Agreement Between Seller and Buyer For Sale on Credit This document has important legal consequences. Consultation with an attorney is recommended with respect to its completion,

More information

General Product Retail Agreement

General Product Retail Agreement General Product Retail Agreement This agreement ("Agreement") is entered into on the day of, 200, by and between NATIONAL RURAL TELECOMMUNICATIONS COOPERATIVE, a District of Columbia corporation ("NRTC"

More information

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS) MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed

More information

Adjustment functions for both span and shift have been incorporated

Adjustment functions for both span and shift have been incorporated SENSORS FOR SERIES LED Type Wafer Alignment Sensor FX-0-F FT-F9 FD-F7 EX-F70/F60 M SH-7 FD-L4 M-DW The use of a safe LED light beam now allows for high precision detection with a resolution of 0!m (.8

More information

QNX Software Systems or QSS means QNX Software Systems International Corporation.

QNX Software Systems or QSS means QNX Software Systems International Corporation. INVOICE TERMS AND CONDITIONS OF SALE (QNX Software Systems designated below as "Seller") DEFINITIONS In these Terms: QNX Software Systems or QSS means QNX Software Systems International Corporation. "Software"

More information

Digital input modules

Digital input modules 8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a

More information

D2QW D2QW-@@@@@- @ - @ 1 2 3 4 5 6 7. Sealed long stroke slide-contact switch for reliable ON/OFF action even in severe environmental conditions.

D2QW D2QW-@@@@@- @ - @ 1 2 3 4 5 6 7. Sealed long stroke slide-contact switch for reliable ON/OFF action even in severe environmental conditions. Sealed long stroke slide-contact switch for reliable ON/OFF action even in severe environmental conditions. Extra-long stroke even without levers. (:.7 mm) Clip contacts with highly reliable slide contact

More information

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual EPM3 Phase Sequence and Motor Rotation Tester Users Manual 1 L1 L2 L3 2 3 A B C CAT 600V 3-PHASE TESTER 5 TEST M1 M2 BATT M3 EPM3 MOTOR ROTATION TESTER EPM3 MOTOR ROTATION DETERMINED WHILE FACING MOTOR

More information

SZR-LY Series. General Purpose Power Relay WARNING WARNING. Sensing and Control

SZR-LY Series. General Purpose Power Relay WARNING WARNING. Sensing and Control Power Relay FEATURES Small package design ARC barrier equipped Silver Cadium Oxide contact High dielectric strength (,800 Vac) High reliability and long life Ultra-high sensitivity with quick response

More information

NA Series. 2 POLES - 1 to 2 A (For Signal Switching) MINIATURE RELAY FTR-K1 SERIES

NA Series. 2 POLES - 1 to 2 A (For Signal Switching) MINIATURE RELAY FTR-K1 SERIES FTR-K1 SERIES MINIATURE RELAY 2 POLES - 1 to 2 A (For Signal Switching) NA Series FEATURES Slim type relay for high density mounting Conforms to Telcordia specification and FCC Part 68 - Dielectric strength

More information

E8F2. Pressure Sensor with Easy-to-Read LED Display. Digital Pressure Sensor. Ordering Information. Sensors (Refer to Dimensions on page 7.

E8F2. Pressure Sensor with Easy-to-Read LED Display. Digital Pressure Sensor. Ordering Information. Sensors (Refer to Dimensions on page 7. Digital Sensor CSM DS_E_4_3 Sensor with Easy-to-Read LED Display status can be checked at a glance from the digital display and bar display. Measurement pressure prevents incorrect outputs due to momentary

More information

Small-diameter Proximity Sensor

Small-diameter Proximity Sensor Small-diameter Proximity Sensor EE Ultra small size, but surprisingly easy installation! With the addition of M,.-dia. size, unshielded, pre-wired connector model, and connector model, a total of 0 model

More information

POWER RELAY. FTR-K1-KS Series. 1 POLE - 16A / Inrush 120A relay FTR-K1 SERIES FEATURES

POWER RELAY. FTR-K1-KS Series. 1 POLE - 16A / Inrush 120A relay FTR-K1 SERIES FEATURES POWER RELAY POLE - 6A / Inrush 20A relay FTR-K-KS Series FTR-K SERIES FEATURES pole 6A, form A or form C Peak inrush current 20A / TV-8 Coil power 400mW High insulation in small package (between coil and

More information

STANDARDS TERMS & CONDITIONS OF SALE

STANDARDS TERMS & CONDITIONS OF SALE STANDARDS TERMS & CONDITIONS OF SALE 1. ENTIRE AGREEMENT. The party to whom goods are being sold, either by means of electronic data interchange or a traditional paper transaction is Buyer. We are Seller.

More information

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Load Cell Amplifier Module. Instruction Manual LCA210-000

Load Cell Amplifier Module. Instruction Manual LCA210-000 Load Cell Amplifier Module Instruction Manual LCA210-000 Table of Contents 1. General Description...3 2. Specifications...3 2.1 Electrical...3 2.2 Physical...4 3. Installation...4 3.1 Wiring Guidelines...4

More information

3. Terminal Shape P : PCB terminals FS: Surface-mounting terminals, short FL : Surface-mounting terminals, long

3. Terminal Shape P : PCB terminals FS: Surface-mounting terminals, short FL : Surface-mounting terminals, long Surfacemounting Relay Ultracompact and Slim DPDT Relay Suitable for highdensity mounting.(.7 mm (W). mm (L) 9 mm (H)). Dielectric strength of, VAC and an impulse withstand voltage of 2, V for 2 μs (conforms

More information

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications. Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description

More information