ProMinent Aquatics List Pricing

Size: px
Start display at page:

Download "ProMinent Aquatics List Pricing"

Transcription

1 ProMinent Aquatics List Pricing February 2012 Section Page 1. DCM Controllers 2 2. Pumps 3 3. CO2 Feeders 4 4. Single Wall Tanks 5 5. Orbeco Test Kits 6 Pricing subject to change without notice Page 1 of 9 5/11/2012

2 DCM 500 Model Selection Guide Part Number Description List DCM 500 Controller for ph, ORP and Temp $3, DCM 501 Controller for ph, ORP and PPM on non stabilized (CYA) water $3, DCM 502 Controller for ph, ORP, PPM and Combined PPM on non stabilized (CYA) water $4, DCM 503 Controller for ph, ORP and PPM with CYA stabilized water $3, DCM 200 Controller for ph, ORP only $1, TBD DCM 300 Controller for ph, PPM only (release date ~ May of 2012) inquire DCM 5 Complete 2-Pool System, with 2 Separate Sample Modules, including ph, ORP and Temp Sensors only 1 temp Configure via E-Quote or Inquire sensor input on DCM 500! Expansion board needed for second temp input $5, Additional options to the above controllers, (changing of probes or to order a two pool DCM5, etc..) must be done via E-quote. Pricing and new controller part number will be generated once DCM5 is configured. Below parts can be used for pricing but any factory installed addition on a controller order will require a configured part number other than above. **Verify all pricing on configured or non-part numbered controllers. Prices are for reference / budget purposes only** DCM 500 SPARE PARTS Model Description List Price ph sensor, Industrial Grade, 38.9mL Inorganic gel, with SN6 connector,25 mm DGMa and 1/2"NPT $ ORP Sensor, 38.9mL Inorganic gel, with proprietary Platinum tip design, SN6 connector, 25 mm DGMa, and 1/2"NPT $ ORP GOLD tip probe, SN mm DGMa $ SN6 to BNC connector for retrofits on controllers with BNC connection, 6ft. $ Conductivity Temperature Sensor Upgrade $ Water level control switch. *valve provided by others* $ Flow sensor for 1/2" to 4" pipe with direct connection to DCM5. Saddle ordered separately $ Flow sensor for 5" to 8" pipe with direct connection to DCM5. Saddle ordered separately $ Flow sensor for 10" and greater pipe with direct connection to DCM5. Saddle ordered separately $ PVC Saddle 2" PVC $ PVC Saddle 3" PVC $ PVC Saddle 4" PVC $ PVC Saddle 6" PVC $ PVC Saddle 8" PVC $ PVC Saddle 10" PVC $ PVC Saddle 12" PVC $ G Wireless Service Module. Includes 1 yr. of monthly service and Wi-Fi network. $1, foot corded Antenna for 3G service $ foot corded Antenna for 3G service $ BRE 1-MA-10PPM Bromine Sensor DCM500 $1, CL CLO 1-10 ppm Free Chlorine Probe for use with Salt Pools or presence of hydrogen in water $1, CL CGE 1-10 ppm. Free Chlorine used when Cyanuric is present $2, CL CLE 3 10 ppm Free Chlorine probe w/o Cyanuric Acid $ CTE CHLORINE SENSOR 1-10 PPM Total / Combined Chlorine Probe $1, CTE SENSOR 1-10 ppm Gold tip. Total / Combined PPM for Salt Pools or presence of hydrogen in water $3, PPM Rebuild Kit (SP SET CGE2/CTE1 W/Membrane Caps) $ Corrosion Kit - Admiralty Brass $ Corrosion Kit - Carbon Steel $ Corrosion Kit Copper $ Corrosion Kit Stainless Steel $ Corrosion Kit Cupro Nickel $ Expansion card kit $ NOTE** Confidential Price Sheet. All pricing is subject to change without prior notice. All pricing is subject to ProMinent's standard terms and conditions Pricing subject to change without notice Page 2 of 9 5/11/2012

3 Typical Pool Beta / Concept Pumps Type Model Output List Rebuild Kit List Concept CNPA1002NPB2B0D psi $ $ Concept CNPA1003NPB2B0D psi $ $ Concept CNPA0704NPB200D psi $ $ Concept CNPA0308NPB2B0D psi $ $ Concept CNPA0215NPB2B0D psi $ $ Beta4 BT4B0220NPB2000UD psi $ $ Beta5 BT5B0420NPB2000UD psi $ $ Beta5 BT5B0232NPB0000UD psi $1, $ Concept Tank Level Switch ft. cable $75.00 Beta Tank Level Switch ft. cable $ For PULSE control on Concept Pumps Replace 2nd to last number with B and add $60.00 to list price. Example CNPA1002NPB2B0DB1 Confidential Price List. All pricing is subject to change without notice. All pricing is subject to ProMinent Fluid Controls standard terms and conditions Quick Reference Guide ProMinent / Stenner/ LMI Manufacture Model PSI Feed Rate GPD Prominent Pump Model List Stenner Concept CNPA1002NPB2B0D01 $ Stenner Concept CNPA0308NPB2B0D01 $ Stenner Concept CNPA1003NPB2B0D01 $ Stenner Concept CNPA0215NPB2B0D01 $ Stenner dual Head Dual Head Concept CNPA0704NPB200D01 $ Stenner dual Head Dual Head Concept CNPA0308NPB2B0D01 $ Stenner dual Head Dual Head Beta BT4B0220NPB2000UD $ Stenner dual Head Dual Head Beta BT5B0232NPB0000UD $1, LMI A Concept CNPA1002NPB2B0D01 $ LMI A Concept CNPA1002NPB2B0D01 $ LMI p Concept CNPA0704NPB200D01 $ LMI A Concept CNPA0704NPB200D01 $ LMI P Concept CNPA0308NPB2B0D01 $ LMI A Concept CNPA0308NPB2B0D01 $ LMI A Beta BT4B0220NPB2000UD $ LMI A Beta BT5B0232NPB0000UD $1, LMI A Sigma S1BAH07042PVTS070N000 $2, LMI A Sigma S1BAH04084PVTS070N000 $2, LMI A Sigma S2BAHM07220PVTS $2, Pricing subject to change without notice Page 3 of 9 5/11/2012

4 ProMinent / ProMaqua CO2 Feeders SAP Part # Description List CO2-200 Feed Unit, SCFH $ CO2-200E Feed Unit, SCFH w/eductor $ CO2 Heater 120V 60Hz (Only) $ GP402 Brass Regulator Dual Stage $ Series 200 Regulator Manifold (Dual Cylinder 24" Leads) [Manual Switchover] $2, SG 900 BR Switchover System (Dual Cylinder 24" Leads) [Semi-Auto Switchover] $2, CO2-D-L Diffuser Low $ CO2-E Eductor (Mazzei) (Includes & Fitting for 3/8 tube connection) $ Pricing is subject to change without notice. All pricing is subject to ProMinent Fluid Controls standard terms and conditions Pricing subject to change without notice Page 4 of 9 5/11/2012

5 ProMinent / ProMaqua Single Wall Tanks Model # Volume Dimensions O.D. x H List Price gallons 18 x 22 $ gallons 20 x 30 $ gallons 26 x 43 $ gallons 32 x 47 $ gallons 42 x 41 $ gallons 43 x 59 $ Pricing is subject to change without notice. All pricing is subject to ProMinent standard terms and conditions Pricing subject to change without notice Page 5 of 9 5/11/2012

6 Orbeco Part Number Description List Price (US$) Discount % LPAP3-10 AquaPRO3 Pool Photometer CL PH CYA $ % LPAP6-10 AquaPRO6 Pool Photometer CL- BR- PH- CYS- TA- CAL $ % MC MC500 Multi- Parameter Colorimeter $ 1, % LPC9 Pool Control 9 Photometer $ 1, % Pool Photometer Accessories MC IRIM (Data Transfer Device) for MC500, AquaPRO3, AquaPRO6 & PC9 $ % L SAMPLE CELLS, 12 PACK ROUND GLASS 24MM DIAMETER WITH LID $ % L CLOTH FOR CLEANING CELLS EA $ % L MM TUBE ADAPTOR EA $ % L Serial connection to computer used for new method updates on MC500 $ % L VERIFICATION STANDARD KIT For Use with MC500 $ % LP REFERENCE STANDARD KIT For Use with AquaPRO 3 & 6 $ % ST EZ MIX PRIMARY CHLORINE STANDARD KIT 1.5 ppm NIST TRACEABLE PRIMARY STANDARD $ % L PLASTIC CRUSHING ROD EA $ % L DILUTION TUBE DILUTIONS TWO, THREE, FIVE AND TEN. $ % L ML SYRINGE EA $ % 9999 TEST TUBE RACK HOLDS SIX SAMPLE CELLS $ % 20% Pool Photometer Reagents 20% RT105-0BT DPD # 1 Tablets (0.01-6ppm) 100ct $ % RT105-0BT DPD # 1 Tablets (0.01-6ppm) 250ct $ % Pricing subject to change without notice Page 6 of 9 5/11/2012

7 Orbeco Part Number Description List Price (US$) Discount % RT106-0BT DPD # 1 Tablets (0.01-6ppm) 100ct $ % RT106-0BT DPD # 1 Tablets (0.01-6ppm) 250ct $ % RT106-2BT DPD # 1 Tablets (0.01-6ppm) 500ct $ % RT108-0BT DPD # 3 Tablets (0.01-6ppm) 100ct $ % RT108-1BT DPD # 3 Tablets (0.01-6ppm) 250ct $ % RT108-2BT DPD # 3 Tablets (0.01-6ppm) 500ct $ % RT122-0BT DPD # 4 Tablets (0.01-6ppm) 100ct $ % RT132-0BT Cyanuric Acid Tablets 100 ct. $ % RT132-1BT Cyanuric Acid Tablets 250ct $ % RT137-0BT CyA Test Tablets (Cyanuric Acid) 100 ct. $ % RT137-1BT CyA Test Tablets (Cyanuric Acid) 250ct $ % RT150-0BT DPD #1 Tablets HR ( ppm) 100ct $ % RT150-1BT DPD #1 Tablets HR ( ppm) 250ct $ % RT150-2BT DPD #1 Tablets HR ( ppm) 500ct $ % RT159-0BT DPD #3 Tablets HR ( ppm) 100ct $ % RT159-1BT DPD #3 Tablets HR ( ppm) 250ct $ % RT159-2BT DPD #3 Tablets HR ( ppm) 500ct $ % RT177-0BT Phenol Red Tablets 100 ct. $ % RT177-1BT Phenol Red Tablets 250ct $ % RT177-2BT Phenol Red Tablets 500ct $ % RT217-0 Glycine Tablets 100 ct. $ % RT235-0 Dechlor Tablets 100 ct. $ % RT238-0 Hydrogen Peroxide LR Tablets 100 ct. $ % Pricing subject to change without notice Page 7 of 9 5/11/2012

8 Orbeco Part Number Description List Price (US$) Discount % RT321-0 ALKA- M Tablets (5-200ppm) 100 ct. $ % RT321-1 ALKA- M Tablets (5-200ppm) 250ct $ % RT324-0 RT324-1 ALKA- M HR Tablets (For AquaPRO 100 photometers) ct. (5-500ppm) $ % ALKA- M HR Tablets (For AquaPRO photometers) (5-500ppm) 250ct $ % RT355-0 Copper # 1 Tablets 100 ct. $ % RT355-1 Copper #1 Tablets 250ct $ % RT356-0 Copper # 2 Tablets 100 ct. $ % RT537-0 Iron LR Tablets 100 ct. $ % RT537-1 Iron LR Tablets 250ct $ % RT538-0 Iron HR 100ct $ % RT542-1 Iron II LR Tablets 250ct $ % RT545-0 Sulfate Tablets 100ct $ % RT566-0 Hardcheck P/Total Hardness Tablets 100 ct. $ % RT570-0 Bromocresol Purple ph ( ) 100ct $ % RT571-0 Thymol Blue ph (8-9.6) 100ct $ % RT574-0 DPD #1 High Calcium Tablets (1000 ppm or greater) 100ct $ % RT610-0 PHMB Tablets 100 ct. $ % RT610-1 PHMB Tablets 250ct $ % RT802-0 Sulfite Tablets 100ct $ % RP030-0 RP055-0 Copper Powder Pack Reagent 100 tests $ % Set (Free) Iron TPTZ Powder Pack Reagent 100 (Total tests Iron) $ % RP056-0 Iron Ferro (II,III Soluble) Powder Pack Reagent 100 tests $ % RP216-0 Sulfate 4 Powder Pack Reagent100 tests $ % Pricing subject to change without notice Page 8 of 9 5/11/2012

9 Orbeco Part Number Description List Price (US$) Discount % RS2620 Zinc Tablets Reagent Set 100ct $ % RS3040 Phosphate LR Tablets Reagent 100ct set ( ppb) $ % RS3550 Copper Tablet Reagent Set (Free & Total) 100ct $ % RS5000 Aluminum Powder Pack Reagent 100 Set tests $ % RS5050 Boron Tablet Reagent Set 100ct $ % RS5090 Managanese LR Powder Pack/Liquid 50 tests Reagent Set $ % RS5370 Iron( II, III Soluble) Tablet Reagent Set 100ct $ % RS5460 Aluminum Tablet Reagent Set 100ct $ % RS5480 Chlorine HR Tablet Reagent Set (5-200 ppm) 100ct $ % RS5480 Chlorine UHR (0.2-16%) Sodium 100ct Hypochlorite $ % RS5500 Ammonia Powder Pack Reagent Set 100ct $ % RS5540 Ammonia Tablet Reagent Set 100ct $ % RS5555 Ozone Tablet Reagent Set 100ct $ % RS5580 Nitrate Tube Test Reagent Set 50 tests $ % RS5910 Chloride Tablet Reagent Set 100ct $ % RS7760 Calcio Hardness Tablet Reagent 100 Set ct. $ % RS7762 Calcio Hardness Tablet Reagent 250ct. Set $ % RS9300 Urea Reagent Set (0.1-3 ppm) 100 tests $ % Pricing subject to change without notice Page 9 of 9 5/11/2012

Specification and Certificate of Analysis

Specification and Certificate of Analysis Reagents History For several decades, Tintometer has been manufacturing reagents for water testing and marketing these reagents around the world under the brand name Lovibond. Different forms of reagents

More information

Automation & Sanitization REPLACEMENT PARTS

Automation & Sanitization REPLACEMENT PARTS & Sanitization PROLOGIC GLX-PCB-PRO Main PCB, ProLogic GLX-PL-LOC-P-4 Display, Local, ProLogic, P-4 GLX-PL-LOC-PS4 Display, Local, ProLogic, PS-4 GLX-PL-LOC-PS8 Display, Local, ProLogic, PS-8 GLX-PL-LOC-PS16

More information

Inline Chlorinator Chlorine Chemical Feeder

Inline Chlorinator Chlorine Chemical Feeder Inline Chlorinator Chlorine Chemical Feeder Instructions Page 1 Chlorine setting in P.P.M. for center tube and cap Hole #1 = 2 P.P.M. Hole #2 = 8 P.P.M. Hole #3 = 30 P.P.M. Hole #A = 3.5 P.P.M. Hole #B

More information

Adjusting Chemical Levels in a Swimming Pool

Adjusting Chemical Levels in a Swimming Pool Adjusting Chemical Levels in a Swimming Pool When adding chemicals, there are three types of chemical adjustments that can be performed: product label chemical dosage, product label chemical adjustment,

More information

Lead Testing and On Site Calibration for Water Testing Detection Range: 2 100ppb

Lead Testing and On Site Calibration for Water Testing Detection Range: 2 100ppb Document: AND Lead 100 7 2013 Lead Testing and On Site Calibration for Water Testing Detection Range: 2 100ppb July, 2013 Edition 1 ANDalyze, Inc., 2012. All rights reserved. Printed in USA. Table of Contents

More information

Thermo Scientific Orion AQUAfast Powder and Tablet Reagent Chemistry User Guide

Thermo Scientific Orion AQUAfast Powder and Tablet Reagent Chemistry User Guide Thermo Scientific Orion AQUAfast Powder and Tablet Reagent Chemistry User Guide for use with AquaMate 7000 Vis and AquaMate 8000 UV-Vis Spectrophotometers 2012 Thermo Fisher Scientific Inc. All rights

More information

Solar Hot Water Heaters

Solar Hot Water Heaters Solar Hot Water Heaters Three High Vacuum Water inlet Stainless Steel screw Gel seal and insulation Water outlet Dust proof seals Non Pressure Models Details ASWH-1b ( Color Painted 304 ) ASWH-1c ( stainless

More information

Troubleshooting Salt Generators

Troubleshooting Salt Generators Troubleshooting Salt Generators NOTE Turn off power to unit prior to attempting service or repair. Problems and Corrective Action Problem Possible Cause Corrective Action Low or no chlorine. Low stabilizer

More information

Reagents also compatible in Hach

Reagents also compatible in Hach Reagents also compatible in Hach VARIO Powder Packs (PP) and Reagents for Photometry Test Range Reagent Liquid Reagent Tube Tests Powder Pack VARIO Aluminium Reagent, Set F20 Aluminium 0 0.22 mg/l Al VARIO

More information

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

TANKLESS WATER HEATER INSTALLATION DIAGRAMS TANKLESS WATER HEATER INSTALLATION DIAGRAMS Installation Diagrams Tankless Installation / Optional Return Small 10-15 Gallon Point-of-Use Water Single and Optional Return : One single, small capacity water

More information

Stenner Pump Chlorinator Installation & Start Up Guide

Stenner Pump Chlorinator Installation & Start Up Guide Clean Water Made Easy www.cleanwaterstore.com Stenner Pump Chlorinator Installation & Start Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance

More information

Chapter 16: Tests for ions and gases

Chapter 16: Tests for ions and gases The position of hydrogen in the reactivity series Hydrogen, although not a metal, is included in the reactivity series because it, like metals, can be displaced from aqueous solution, only this time the

More information

Understanding basic pool chemistry is one of the most important factors in pool maintenance. Properly balanced water creates an environment that

Understanding basic pool chemistry is one of the most important factors in pool maintenance. Properly balanced water creates an environment that Understanding basic pool chemistry is one of the most important factors in pool maintenance. Properly balanced water creates an environment that optimizes the disinfection process and protects the pool

More information

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases

More information

Chlorine, Total. DPD Method 1 Method 10101 0.09 to 5.00 mg/l Cl 2 Test 'N Tube Vials. Test preparation. Instrument-specific information

Chlorine, Total. DPD Method 1 Method 10101 0.09 to 5.00 mg/l Cl 2 Test 'N Tube Vials. Test preparation. Instrument-specific information Chlorine, Total DOC316.53.01028 DPD Method 1 Method 10101 0.09 to 5.00 mg/l Cl 2 Test 'N Tube Vials Scope and application: For testing higher levels of total (free plus combined) chlorine in drinking water,

More information

Advanced Heating & Hot Water Systems. Ultra High Efficiency Energy Star Listed Condensing Boiler

Advanced Heating & Hot Water Systems. Ultra High Efficiency Energy Star Listed Condensing Boiler Advanced Heating & Hot Water Systems A Trailblazing Energy Star Listed Boiler that Installs like a Mid-Efficiency Boiler with the Performance of a High-Efficiency Product Ultra High Efficiency Energy Star

More information

Anytime from anywhere on earth. and control system with remote access. Pentair. automation

Anytime from anywhere on earth. and control system with remote access. Pentair. automation Anytime from anywhere on earth IntelliPool TM Pool monitoring and control system with remote access CONTROL 12/07/10 15:23:48 Water temp:+24.0 C ph:7,3 ORP:629mV Cond:5571uS 3.51g/l ESC ENTER PROBE UNIT

More information

DR/4000 PROCEDURE. CHLORINE, Free

DR/4000 PROCEDURE. CHLORINE, Free DR/4000 PROCEDURE CHLORINE, Free Method 10069 DPD method* UHR (0.1 10.0 mg/l as Cl 2 ) Scope and Application: For testing higher levels of free chlorine (hypochlorous acid and hypochlorite ion) in drinking

More information

OPSIS LiquidLINE KjelROC Distillation Unit

OPSIS LiquidLINE KjelROC Distillation Unit OPSIS LiquidLINE KjelROC Distillation Unit Distillation System with Unique Level of Serviceability and Automation LP 1002 Why KjelROC Distillation Unit? In many tests there is a need to separate the substance

More information

ELECTROCHEMISTRY. BOECO ELECTRODES The electrodes are not included with the ph meters and have to be ordered separately:

ELECTROCHEMISTRY. BOECO ELECTRODES The electrodes are not included with the ph meters and have to be ordered separately: BOECO PORTABLE PH/ORP/TEMP METER MODEL PT-380 A Simultaneous displays ph or mv and temperature. A Convenient calibration with automatic buffer recognition of European and US buffer sets. Calibration data

More information

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing) CHRONOMITE INSTANT-FLOW MICRO WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No.

More information

D. Open hydronic systems, including [condenser] [fluid-cooler spray] water, shall have the following water qualities:

D. Open hydronic systems, including [condenser] [fluid-cooler spray] water, shall have the following water qualities: SECTION 232500 - PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following HVAC water-treatment systems: 1. Open Loop Chemical Treatment Systems. 2. Closed Loop Chemical Treatment Systems. 3.

More information

Galvanic Parts Per Million Dissolved Oxygen Systems

Galvanic Parts Per Million Dissolved Oxygen Systems Galvanic Parts Per Million Dissolved Oxygen Systems Model 900 Portable s Model 9100 Model 9200 Model 9300 The Royce line of PPM level dissolved oxygen (DO) analyzers is the largest, most varied line in

More information

b. Alkalinity make your life easier and get the alkalinity between 80 and 120 PPM. c. ph from 7.2 and 7.8 so that the other chemicals work properly

b. Alkalinity make your life easier and get the alkalinity between 80 and 120 PPM. c. ph from 7.2 and 7.8 so that the other chemicals work properly 1. Adding Chemicals to your water: Chemicals should be added slowly over a period of time. Pool owner/operators need to remember that all chemicals added will have an effect beyond their intended purpose.

More information

PortaSens ll G AS DETECTOR

PortaSens ll G AS DETECTOR PortaSens ll G AS DETECTOR ONE DETECTOR... FOR MANY GASES! Sensors can be exchanged quickly and easily without the need for calibration. Sensors are maintained in ready condition in the optional sensor

More information

Ion Selective Electrodes

Ion Selective Electrodes Ion Selective Electrodes OAKTON has a large selection of Ion Selective Electrodes () to suit a wide variety of applications. Each electrode has a typical response time of 20 to 30 seconds but will vary

More information

Common Problems with Online Water Quality Analyzers. Greg Macy Director AquatiPro LLC

Common Problems with Online Water Quality Analyzers. Greg Macy Director AquatiPro LLC Common Problems with Online Water Quality Analyzers Greg Macy Director AquatiPro LLC Objectives Diagnosing Colorimetric Analyzers Identifying Common Problems with Sodium Analyzers Troubleshooting ph Analyzers

More information

LACHAT METHOD NUMBER 10-204-00-5-D Rev 1, 21 March 2011 SCOPE AND APPLICATION Approximately 3-500 g CN/L 2-500 g CN/L. 09e

LACHAT METHOD NUMBER 10-204-00-5-D Rev 1, 21 March 2011 SCOPE AND APPLICATION Approximately 3-500 g CN/L 2-500 g CN/L. 09e 1 SIDE BY SIDE COMPARISON TABLE FOR THE DETERMINATION OF CYANIDE BY UV DIGESTION AND AMPEROMETRIC DETECTION FIA METHOD - 10-204-00-5-D (ASTM D7511-09 e ) TOPIC Method ASTM D7511-09e LACHAT METHOD NUMBER

More information

CONVERTING A CLOSED-LOOP WATER SYSTEM TO A GLYCOL SYSTEM

CONVERTING A CLOSED-LOOP WATER SYSTEM TO A GLYCOL SYSTEM CONVERTING A CLOSED-LOOP WATER SYSTEM TO A GLYCOL SYSTEM Presented at Alberta Public Works, Supply & Services Property Management Water Treatment Co-ordinators' Meeting #29 Roland Michener Recreation Centre

More information

WATER CHEMISTRY AND POOL WATER BALANCE

WATER CHEMISTRY AND POOL WATER BALANCE C R6 H A PT E WATER CHEMISTRY AND POOL WATER BALANCE LEARNING OBJECTIVES After completely studying this chapter, you should be able to: Understand and list the parameters upon which water balance is based.

More information

POOL SUNSHINE IONIZER MODELS SPD, SPD2 AND SPS INSTALLATION INSTRUCTIONS

POOL SUNSHINE IONIZER MODELS SPD, SPD2 AND SPS INSTALLATION INSTRUCTIONS Sunshine Pool Products, LLC Manufacturer of Quality Pool & Spa Products 902 W 2010 S, Syracuse, Utah 84075 USA Voice: 801-825-4523 Website: www.sunshinepool.com Email: info@sunshinepool.com POOL SUNSHINE

More information

ASME Packaged Indirect Fired Water Heater

ASME Packaged Indirect Fired Water Heater Utilizes Or HTHW To Heat Domestic Water, Semi-Instantaneous or Storage Type Model BW Features Reliable Only high grade materials used in construction to ensure long operating life Hydrastone cement lining

More information

General Purpose ph/orp Sensors

General Purpose ph/orp Sensors General Purpose ph/orp Sensors Product Data Sheet LIQ_PDS_3900 / Rev. F December 2014 General Purpose ph/orp Sensors SMART preamplifier-stores calibration and other data. Extended sensor life provided

More information

NAVIEN AMERICA INC. 17855 FITCH AVENUE

NAVIEN AMERICA INC. 17855 FITCH AVENUE Navien America Inc. Specification Details for the Navien models: CC-240 CC-240A For Potable Water Heating and Space Heating NAVIEN AMERICA INC. 17855 FITCH AVENUE IRVINE, CALIFORNIA, USA 92614 Toll Free:

More information

API Marine. BMS Presentation. Ballast Measurement Systems

API Marine. BMS Presentation. Ballast Measurement Systems API Marine BMS Presentation Ballast Measurement Systems BMS4 Typical Configuration BMS4 Typical Configuration BMS4 Extended Configuration BMS4 System (24 tanks) Air regulator Terminal block Drain/Air Filter

More information

LZV585 (B) The 1-cm path is aligned with the arrow on the adapter. 5940506

LZV585 (B) The 1-cm path is aligned with the arrow on the adapter. 5940506 Chlorine, Total DOC316.53.01029 USEPA DPD Method 1 Method 10070 0.1 to 10.0 mg/l Cl 2 (HR) Powder Pillows Scope and application: For testing higher levels of total chlorine (free and combined) in drinking

More information

ANTENNA PARTS CATALOG

ANTENNA PARTS CATALOG ANTENNA PARTS CATALOG Maco Antennas 302 S. East St. Mt. Carroll, IL 61053 www.macoantennas.net 815-244-3500 www.antennapartsoutlet.com SCREWS / BOLTS PART SIZE LENGTH DESCRIPTION PRICE S21 10-24 1/2" Machine

More information

WHAT DOES A SWIMMING POOL OPERATOR NEED TO KNOW?

WHAT DOES A SWIMMING POOL OPERATOR NEED TO KNOW? WHAT DOES A SWIMMING POOL OPERATOR NEED TO KNOW? 1. POOL VOLUME The volume of your pool is the most important number you need to know. The volume is the number of gallons of water in your pool. a. The

More information

AQUAPRO INDUSTRIAL CO.,LTD. Reverse Osmosis Parts Introduction

AQUAPRO INDUSTRIAL CO.,LTD. Reverse Osmosis Parts Introduction Reverse Osmosis Parts Introduction Reverse Osmosis Flow Chart AQUAPRO INDUSTRIAL CO.,LTD Triple Membrane WATER IMPROVER WATER IMPROVER 2 Reverse Osmosis Electrical Diagram AC-220V Power (2.0 point) (W)

More information

HOSE, TUBE, AND PIPE CLAMPS

HOSE, TUBE, AND PIPE CLAMPS hose, tube & clamp B/W pages 24/6/08 9:28 AM Page 2 HOSE, TUBE, AND PIPE CLAMPS TABLE OF CONTENTS Introduction 3 Construction 3 Application 3 Mounting 3 Standard Duty Clamps (HRL) Arrangements 4 Dimensions

More information

Micro GC Fusion Pre-Installation Checklist

Micro GC Fusion Pre-Installation Checklist Site Preparation Proper site preparation prior to installing is very important. Contact INFICON (www.inficon.com) with any questions regarding site preparation. NOTE: Checkboxes ( ) identify hardware that

More information

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters FEATURES ULTRA-LOW NOx CONDENSING TECHNOLOGY PROVIDES UNPRECEDENTED 0.95 ENERGY FACTOR DURABLE HEAT EXCHANGER Primary Heat Exchanger

More information

Best Practice in Boiler Water Treatment

Best Practice in Boiler Water Treatment Best Practice in Boiler Water Treatment Boiler Water Treatment Part 2 Internal Treatment Objectives of Internal Water Treatment 1 To control the level of total dissolved solids (TDS) within the boiler

More information

Overheating limit control

Overheating limit control Pahlén electric heater Maxi Heat with digital control is a compact and effective heater for swimming pools. It consists of a glassfibre reinforced polypropylene tank containing resistance-type heating

More information

DRAFT July, 2006 Page 1 of 18

DRAFT July, 2006 Page 1 of 18 DRAFT July, 2006 Page 1 of 18 Swimming Pool Venue Environmental Health Outbreak Investigation Survey: An Environmental Health Systems Approach to Recreational Water Illness Prevention - Information Collection

More information

Decomposition. Composition

Decomposition. Composition Decomposition 1. Solid ammonium carbonate is heated. 2. Solid calcium carbonate is heated. 3. Solid calcium sulfite is heated in a vacuum. Composition 1. Barium oxide is added to distilled water. 2. Phosphorus

More information

Cadmium Reduction Method Method 8039 0.3 to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

Cadmium Reduction Method Method 8039 0.3 to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls Nitrate DOC316.53.01066 Cadmium Reduction Method Method 8039 0.3 to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls Scope and application: For water, wastewater and seawater. Test preparation Instrument-specific

More information

globe reactions made easy Process perfection

globe reactions made easy Process perfection globe reactions made easy Process perfection Benefits More reactions in less time: The Globe oil drain unit and quick clamp allow single hand vessel changes in seconds Space saving: 50ml, 100ml, 250ml,

More information

8 Chemicals from water treatment and distribution

8 Chemicals from water treatment and distribution 8 Chemicals from water treatment and distribution 8.1 Introduction Chemicals from water treatment and distribution reach drinking-water by the most direct route. They fall into three broad categories:

More information

Method 8155 NITROGEN, AMMONIA (0 to 0.50 mg/l NH 3 -N) For water, wastewater, seawater

Method 8155 NITROGEN, AMMONIA (0 to 0.50 mg/l NH 3 -N) For water, wastewater, seawater Method 8155 NITROGEN, AMMONIA (0 to 0.50 mg/l NH 3 -N) For water, wastewater, seawater Salicylate Method * 1. Enter the stored program number for ammonia nitrogen (NH 3 -N). 2. Press: 64 ENTER The display

More information

kajaanipolarox Measure and Control Active Bleaching Chemicals kajaani

kajaanipolarox Measure and Control Active Bleaching Chemicals kajaani kajaanipolarox Measure and Control Active Bleaching Chemicals kajaani Measured Chemical Meas.range [g/l] Cl 2 (chlorine) 0...4 (chlorine dioxide) 0...1.5 ClO - 2 (chlorite) 0...1.5 / SO 2 or NaHSO 3 (chlorine

More information

The Control of ph and Oxidation Reduction Potential (ORP) in Cooling Tower Applications By Charles T. Johnson, Walchem Corporation

The Control of ph and Oxidation Reduction Potential (ORP) in Cooling Tower Applications By Charles T. Johnson, Walchem Corporation The Control of ph and Oxidation Reduction Potential (ORP) in Cooling Tower Applications By Charles T. Johnson, Walchem Corporation Introduction The importance of keeping cooling tower water in proper chemical

More information

Heating Cable. Construction

Heating Cable. Construction Mineral Insulated High Temperature A C Constant Wattage Series Resistance Heating Cable Sets Process Temperature Maintenance to F (593 C) Maximum Exposure Temperature 4 F (76 C) (Power Off) Corrosion Resistant

More information

OXIGENO DISUELTO. Dissolved Oxygen. Install & forget. Sistema autolimpiable. Autoclean system

OXIGENO DISUELTO. Dissolved Oxygen. Install & forget. Sistema autolimpiable. Autoclean system Sistema autolimpiable Dissolved Oxygen Autoclean system Applications: - water treatment - activated sludge - de-nitrification - fish pond Install & forget For special applications, the D.O monitor can

More information

Continuous-Flow Analyzers

Continuous-Flow Analyzers _ Continuous-Flow Analyzers _ Rapid Control of Fertilizer Quality with the AutoAnalyzer Legislation and quality requirements have led to the need for close control of fermentation and finished products

More information

USEPA 1 FerroVer Method 2 Method 8008 0.02 to 3.00 mg/l Fe Powder Pillows or AccuVac Ampuls

USEPA 1 FerroVer Method 2 Method 8008 0.02 to 3.00 mg/l Fe Powder Pillows or AccuVac Ampuls Iron, Total DOC316.53.01053 USEPA 1 FerroVer Method 2 Method 8008 0.02 to 3.00 mg/l Fe Powder Pillows or AccuVac Ampuls Scope and application: For water, wastewater and seawater; digestion is required

More information

The Unique Accelabar Flow Meter

The Unique Accelabar Flow Meter The Unique Accelabar Flow Meter The Accelabar is a new and unique flow meter that combines two differential pressure technologies to produce operating ranges never before attainable in a single flow meter.

More information

Commercial Semi-Instantaneous Water Heaters

Commercial Semi-Instantaneous Water Heaters FEATURES HWI Models A. O. Smith s HWI models are available for operation with steam or boiler water as the energy source. They are factory assembled with components sized, piped and checked at the factory

More information

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) CHRONOMITE INSTANT-FLOW WATER HEATER INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected) TABLE 1 Model No. Wattage

More information

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat Document No. 155-068P25 TH 193-4 Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 193 HC thermostats are proportional dual

More information

Swimming Pool and Spa Water Chemical Adjustments

Swimming Pool and Spa Water Chemical Adjustments Swimming Pool and Spa Water Chemical Adjustments John A. Wojtowicz Chemcon This paper deals with adjustments to swimming pool and spa water chemical parameters such as ph, alkalinity, hardness, stabilizer,

More information

SCH 4C1 Unit 2 Problem Set Questions taken from Frank Mustoe et all, "Chemistry 11", McGraw-Hill Ryerson, 2001

SCH 4C1 Unit 2 Problem Set Questions taken from Frank Mustoe et all, Chemistry 11, McGraw-Hill Ryerson, 2001 SCH 4C1 Unit 2 Problem Set Questions taken from Frank Mustoe et all, "Chemistry 11", McGraw-Hill Ryerson, 2001 1. A small pin contains 0.0178 mol of iron. How many atoms of iron are in the pin? 2. A sample

More information

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

Powers Controls TH 192 HC Heating/Cooling Room Thermostat Powers Controls TH 192 HC Heating/Cooling Room Thermostat Technical Instructions Document No. 155-066P25 TH 192-2 50 60 70 80 70 TH0356R1 60 80 POWERS Description The TH 192 HC thermostats are proportional

More information

Scotch-Weld PUR Easy 250 Adhesive Applicator

Scotch-Weld PUR Easy 250 Adhesive Applicator Scotch-Weld September, 2014 Product Description PUR Easy 250 Applicator is a self contained pneumatic applicator designed to dispense 1/10 th gallon(300ml) cartridges of 3M PUR adhesives. PURs are a family

More information

Experiment 8 - Double Displacement Reactions

Experiment 8 - Double Displacement Reactions Experiment 8 - Double Displacement Reactions A double displacement reaction involves two ionic compounds that are dissolved in water. In a double displacement reaction, it appears as though the ions are

More information

System Accessories Pricing. Page 0 Effective 7/02

System Accessories Pricing. Page 0 Effective 7/02 System Accessories Pricing Page 0 Effective 7/02 Firetrace Tubing 200005 Firetrace Detection Tubing (FDT) (Per Foot) (Available in continuous lengths up to 333 ft.) Accessories 400001 400004 400061 400060

More information

Index 11.1. Page. Pumping Systems...11.2-11.4 Intensifiers...11.5 Gas Boosters...11.6-11.7 High Pressure Generators...11.8-11.9

Index 11.1. Page. Pumping Systems...11.2-11.4 Intensifiers...11.5 Gas Boosters...11.6-11.7 High Pressure Generators...11.8-11.9 Pumping Systems, Intensifiers, Gas Boosters and High Pressure Generators High Pressure Equipment Company produces a number of components and systems for general industrial, elevated pressure applications.

More information

Appendix D lists the Field Services Standard Operating Procedures. Appendix E lists the Biological Monitoring Standard Operating Procedures.

Appendix D lists the Field Services Standard Operating Procedures. Appendix E lists the Biological Monitoring Standard Operating Procedures. Page 16 of 87 3.3 Sample Collection, Storage and Preservation Figure 3 details required containers, sample volumes, preservation techniques, and holding times for proper sample collection. A discussion

More information

Anodes and Misc Equipment

Anodes and Misc Equipment Anodes and Misc Equipment Application: Platinised Titanium Anodes Platinised titanium anodes are recommended for use in the following electrolytic processes:- Precious metal electroplating - e.g. Au, Pt,

More information

Global Water Instrumentation, Inc.

Global Water Instrumentation, Inc. Global Water Instrumentation, Inc. 11390 Amalgam Way Gold River, CA 95670 T: 800-876-1172 Int l: (916) 638-3429, F: (916) 638-3270 Temperature Sensor: WQ101 ph Sensor: WQ201 Conductivity Sensor: WQ301

More information

2014 SWIMMING POOL SUPPLY CATALOG EQUIPMENT INDEX

2014 SWIMMING POOL SUPPLY CATALOG EQUIPMENT INDEX 2014 SWIMMING POOL SUPPLY CATALOG PHONE: (540) 345-7665 FAX: (540) 343-5240 EQUIPMENT INDEX CHLORINATORS 2 DIVING BOARDS 7 FILTERS 4 HANDICAP LIFTS 8 HANDRAILS 9 HEATERS 4 JUNCTION BOX 6 LADDERS 8 LIFEGUARD

More information

Single-Gas Detector. Long-term solution. h Class I, Div. 1, Gr. A, B, C, D 4 5062-26-NCL-EN

Single-Gas Detector. Long-term solution. h Class I, Div. 1, Gr. A, B, C, D 4 5062-26-NCL-EN Single-Gas Detector H 2 S, CO, O 2, SO 2, NH 3, PH 3, Cl 2, ClO 2, NO, NO 2, HCN, ETO, O 3 Long-term solution Compact and affordable, the GasAlert Extreme reliably monitors for any single gas hazard within

More information

Flow Solution Parts & Accessories

Flow Solution Parts & Accessories Flow Solution Parts & Accessories Assemblies Part # Instrument U/M Price Debubbler Debubbler, Acrylic A000172 All ea $140.00 Distillation Coil Heater Spool A515017 FS III/IV ea $495.00 Digestion Coil UV

More information

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification 1.0 This specification details the attributes and operating characteristics of the MSA Ultima X Series sensors/transmitters.

More information

Split Controller. User Manual SM-SS-F 2009/01/04

Split Controller. User Manual SM-SS-F 2009/01/04 Split Controller SM-SS-F User Manual 2009/01/04 Table of contents 1. Parts illustration.... 1 2. Electrical technical data...... 2 3. Electrical connection...3 4. Assemble parts...4 4.1 Assemble the fixed

More information

450TOC Analyzer. Portable, Real-time, Continuous Total Organic Carbon Measurement. 450TOC Analyzer

450TOC Analyzer. Portable, Real-time, Continuous Total Organic Carbon Measurement. 450TOC Analyzer 450 Analyzer 450 Analyzer Fast, Continuous Measurement Compliant with USP, Ch P, EP and JP USB Data Logging and Printer Output Robust Portable Design Portable, Real-time, Continuous Total Organic Carbon

More information

W1 WORKSHOP ON STOICHIOMETRY

W1 WORKSHOP ON STOICHIOMETRY INTRODUCTION W1 WORKSHOP ON STOICHIOMETRY These notes and exercises are designed to introduce you to the basic concepts required to understand a chemical formula or equation. Relative atomic masses of

More information

Donut Robot Mark I Mark VI

Donut Robot Mark I Mark VI The worldwide leader in donut production equipment +1.206.322.5474 info@belshaw.com www.belshaw.com AUTOMATIC FRYERS Donut Robot Mark I Mark VI Donut Robot Series Automatic Fryers deposit, fry, turn, and

More information

2014 Service Technician Training Program Closed Loop Systems

2014 Service Technician Training Program Closed Loop Systems 1/20/14 2014 Service Technician Training Program Closed Loop Systems Daniel S. Krack, CWT 2 Closed Loop Cooling and Heating The Closed Loop Cooling Advantages High Efficiency Chillers, Heat Exchangers,

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm Specifications Features Type REED HALL EFFECT NPN or PNP Applicable Series Configurations Construction Materials Body Mounting Bracket Cable Characteristics Operating Temperature Accuracy All Cylinders

More information

LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER

LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER System for flow measurement, data acquisition and transmission for wastewater with long battery life With Long Life Battery Open Channel Flow Meter

More information

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS up to size 381; to PN 0.5; to T = 80 C 1. Description 1.1. General FSA fluid level gauges, FSK fluid level sensors and TS temperature

More information

Calculating Molar Mass of a Compound

Calculating Molar Mass of a Compound Instructions for Conversion Problems For every conversion problem Write the number in the problem down with unit and a multiplication sign Decide which conversion factor you should use, Avagadro s or molar

More information

C. Provide temporary water treatment for chilled, hot and condenser water until facility has final connections.

C. Provide temporary water treatment for chilled, hot and condenser water until facility has final connections. SECTION 23 25 00 - HVAC WATER TREATMENT PART 1 -GENERAL 1.1 SUMMARY A. This Section includes the following: 1. HVAC water-treatment systems. 2. Chemical treatment test equipment. 3. HVAC water-treatment

More information

Milwaukee USER MANUAL

Milwaukee USER MANUAL Milwaukee USER MANUAL PORTABLE DISSOLVED OXYGEN METER MODEL: MW600 Smart DO Meter PROBE PREPARATION: The meter is supplied with a 9V battery. Slide off the battery compartment cover on the back of the

More information

1 of 8 5/10/2010 12:47 AM

1 of 8 5/10/2010 12:47 AM 1 of 8 5/10/2010 12:47 AM All, There seems to be a lot of confusion on the various acid mixtures used in the different reactions. I've put together this quick list of reaction mixes. I know it's incomplete

More information

Measurement by Ion Selective Electrodes

Measurement by Ion Selective Electrodes Measurement by Ion Selective Electrodes Adrian Vazquez May 8, 2012 Why Use Ion Selective Electrodes? Responsive over a wide concentration range Not affected by color or turbidity of sample Rugged and durable

More information

DERON Air/Water Swimming pool Heat Pump. CY/DY series for Heating/Cooling. Description

DERON Air/Water Swimming pool Heat Pump. CY/DY series for Heating/Cooling. Description Description Compact air/water heat pump for outside installation. With suction gas cooled rotary compressor. With extensive aluminium/cu lamellar tube evaporator and PVC Titanium condenser. Axial fan Refrigerant

More information

The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO

The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO The Breather Box High Performance Grade-D Breathing Air Filtration system Specifications Filter change Indicators Incoming Air Plug 1/2 Industrial Interchange 2 Automatic Drains with Discharge tubes 3

More information

Phosphorus, Reactive (Orthophosphate)

Phosphorus, Reactive (Orthophosphate) Phosphorus, Reactive (Orthophosphate) DOC316.53.01113 Amino Acid Method 1 Method 8178 0.23 to 30.00 mg/l PO 4 Reagent Solution Scope and application: For water, wastewater and seawater. 1 Adapted from

More information

Accumulators and Receivers

Accumulators and Receivers aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Accumulators and Receivers Catalog C-1, October 2007 Page 2 / Catalog

More information

Treatment options for hydrogen sulfide. Testing for hydrogen sulfide

Treatment options for hydrogen sulfide. Testing for hydrogen sulfide Sometimes hot water will have a sour smell, similar to that of an old damp rag. This smell often develops when the thermostat has been lowered to save energy or reduce the potential for scalding. Odor-causing

More information

Section 4: NiResist Iron

Section 4: NiResist Iron Section 4: NiResist Iron Section 4 Ni-Resist Description of Grades...4-2 201 (Type 1) Ni-Resist...4-3 202 (Type 2) Ni-Resist...4-6 Stock Listings...4-8 4-1 Ni-Resist Description of Grades Ni-Resist Dura-Bar

More information

4.0 EXPERIMENT ON DETERMINATION OF CHLORIDES

4.0 EXPERIMENT ON DETERMINATION OF CHLORIDES 4.0 EXPERIMENT ON DETERMINATION OF CHLORIDES Sl. No. Contents Preamble 4.1 Aim 4.2 Introduction 4.2.1 Environmental Significance 4.3 Principle 4.4 Materials Required 4.4.1 Apparatus Required 4.4.2 Chemicals

More information

Mitos P-Pump. product datasheet

Mitos P-Pump. product datasheet product datasheet page Product description 2 Main benefits 3 Why choose the Mitos P-Pump? 3 Closed-loop flow control 4 Product specifications 5 Accessories - overview 6 Mitos P-Pump Basic 7 Mitos P-Pump

More information

2015 PRICE LIST. PRICING EFFECTIVE JULY 06, 2015 30121-63 Rev. 1.3/07-15 Supersedes Price List April 1, 2014, Rev. 1.2/02-15

2015 PRICE LIST. PRICING EFFECTIVE JULY 06, 2015 30121-63 Rev. 1.3/07-15 Supersedes Price List April 1, 2014, Rev. 1.2/02-15 2015 PRICE LIST PRICING EFFECTIVE JULY 06, 2015 30121-63 Rev. 1.3/07-15 Supersedes Price List April 1, 2014, Rev. 1.2/02-15 Subject to change without notice. Prices F.C.A. Factory Warehouse 3255 WEST STETSON

More information

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410 The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a

More information

Determining the Quantity of Iron in a Vitamin Tablet. Evaluation copy

Determining the Quantity of Iron in a Vitamin Tablet. Evaluation copy Determining the Quantity of Iron in a Vitamin Tablet Computer 34 As biochemical research becomes more sophisticated, we are learning more about the role of metallic elements in the human body. For example,

More information

OT 40L / 90L. Laboratory Steam Sterilizers

OT 40L / 90L. Laboratory Steam Sterilizers OT 40L / 90L Laboratory Steam Sterilizers OT 40L / 90L LABORATORY STEAM STERILIZERS OT 40L / OT 90L laboratory steam sterilizers are specially designed for the steam sterilization of liquid and culture

More information