1 Inline Chlorinator Chlorine Chemical Feeder Instructions Page 1 Chlorine setting in P.P.M. for center tube and cap Hole #1 = 2 P.P.M. Hole #2 = 8 P.P.M. Hole #3 = 30 P.P.M. Hole #A = 3.5 P.P.M. Hole #B = 13 P.P.M. Hole #C = 40 P.P.M. All holes closed will deliver 60 P.P.M per pump cycle. This chart is for a 42 gallon or equivalent pressure tank. When using an 80 gallon pressure tank, the P.P.M. amount will be 50% less per pump cycle. A 20 gallon pressure tank will yield 2 times the amount. Each number or letter will show a different hole in the cap. Line up the 3 holes in the cap with the proper number or letter directly under it (as per figure 1). The hole in the tube should show in the center of the hole in the cap. UNITS MUST BE INSTALLED AFTER PRESSURE TANK Install P.V.C. check valve BEFORE the feeder if water is used after pressure tank and before feeder inlet. USE CAUTION WHEN DRAINING CHLORINE: Chlorine can bleach clothes and may burn eyes and skin. See manufacturer details for proper handling. When removing center tube for cleaning, check hole setting in cap. After cleaning, be sure the setting is the same before replacing the cap. Center tube MUST BE REMOVED AND CLEANED or replaced with the extra center tube and cap each time before refilling. REMOVE CHEMICAL FROM "FEEDER" WHEN NOT BEING USED!
2 Refilling Information for Model 400 Inline Chlorinator Chlorine Chemical Feeder Instructions Page 2 1. Shut off water ahead of feeder. 2. Open drain valve after feeder and relieve line pressure. 3. Unscrew top (No. 4) and remove adjustment tube (No. 8) to drain unit and replace with a clean tube and cap (No. 7). To clean the removed tube and cap, soak in a mixture of Muriatic Acid. One part Muriatic Acid to 5 parts water. Always pour the acid into the water. ADHERE TO THE WARNINGS FOR HANDLING AND USE OF MURIATIC ACID. Tube and Cap can also be cleaned by soaking in white vinegar over night or longer. 4. Unit Housing needs cleaning when center hole has builtup (under tube No. 8). Unscrew unions (No. 14), remove housing and soak in same mixture of Muriatic Acid as tube No. 8 until clean. Be sure flow arrow is in the same direction when reinstalling housing. 5. Fill with chlorine tablets to the bottom of cap (No. 7) and do not add water to the unit or operation will be inhibited. It may take a few pump cycles before chlorine is despensed. 6. Replace top (No. 4) and close drain valve. 7. Turn on water. If unit is used for odor removal, do not refill until odor returns to minimize chemical use. DANGER: DO NOT MIX DIFFERENT TYPES OR BRANDS OF CHLORINE AN EXPLOSION CAN OCCUR!
3 Inline Chlorinator Chlorine Chemical Feeder Instructions Page 3 INSTALLATION AND OPERATION INFORMATION The UNIVERSAL CHEMICAL FEEDER will operate on a varying pressure such as a home well system or on a constant pressure such as a sprinkler or pool system. When used as a constant pressure system, the optional rate of feed valve (No. 20) must replace N0. 11 valve as received. A charcoal filter must follow the CHEMICAL FEEDER on a varying pressure system for proper operation. Tests have shown that one cube of coconut shell based activated carbon is the best carbon to use (grade 9/50, mesh 8/30). We recommend installing the CHEMICAL FEEDER and filter tank before or after the softener. If installed before the softener, the filter will need periodic back washing. There are seven positions for varying the amount of chemical feed. Rotate the top cap (No. 7) so there is a hole showing through the level desired. There are two hole selections for each hole in the cap (No. 7). The smaller hole will dispense the greatest amount and selecting a lower hole on the cap will increase the output. Approximate chlorine readings using a 42 gallon pressure tank out of the CHEMICAL FEEDER per pump cycle in PPM, for each hole are: 1=2, A=3.5, 2=8, B=13, 3=30, C=40 and with no holes showing, the off position is 60 plus. These readings are obtained with no iron or hydrogen sulfide using the chlorine. Variables that will change the dilution are: pressure tank size, large volumes of water flow while pump is building pressure to shut off, horse power of the pump, and a water logged pressure tank or air pressure is low or high in the air bag. The CHEMICAL FEEDER will dispense the same amount of chemical for each cycle of the pump from maximum to minimum pressure. When used on a constant pressure and flow it is necessary to replace the valve (No. 11). Replace it with the optional adjustable valve (No. 20). It may be necessary to install the optional screen filters (No. 19) in the top inside hole of (No. 8) and screen (No. 18) in the adjustable inlet hole when using chemicals other than chlorine. When using the unit for constant pressure and flow such as a sprinkler system or pool; install the unit on the output to the sprinkler heads or on the return line to the pool. The adjustments for the varying pressure system should have no holes shown through in the off position. The amount of chemical dispensed is controlled with the adjustable valve on the outside of the unit. It may be necessary to adjust the unit if flow is increased or decreased.
4 Inline Chlorinator Chlorine Chemical Feeder Instructions Page 4 (Actual size of the CHEMICAL FEEDER " high X 11.5" long Empty weight lbs.) Maximum tested pressure is 80 lbs. CAUTION: USE ONLY CALCIUM HYPOCHLORITE CHLORINE TABLETS FOR POTABLE WATER. THEORY OF OPERATION After filling the unit with chemical to no higher than the bottom of the adjustable cap or less and returning water flow, fluid will flow into the chemical container mixing with the chemical until the air trapped in the top of the unit is compressed to the same pressure as the line pressure. When the line pressure is reduced, compressed air in the air chamber will force fluid from the container down and up through the outside center tube and down the inside tube to the water line until pressure is equal or until the fluid level reaches the hole that is open in the outside tube. At that time, the compressed air will flow through the hole into the outside tube, down the inside tube and no more fluid will flow. This procedure will occur on each pump cycle. The outside tube has six (6) holes with three of them smaller. The cap can be rotated to select either a large hole or a small hole in six different locations. During fluid flow, a small amount of fluid will flow through the hole selected thereby diluting the fluid flowing up through the outside tube. Most chemical solutions are heavier than water and the top of the fluid is not as heavily saturated as the bottom of the container. Selecting a small hole will increase the chemical concentration and selecting a lower hole increases the solution output. The unit can be used as a venturi operation for operations other than varying pressure. In this mode, the cap may be rotated so there is no hole through the outside tube or left with the hole through the outside tube to help dilute the fluid if needed. The chemical solution put out is controlled with the optional rate of feed valve on the outside of the unit. WARNING: DO NOT MIX DIFFERENT TYPES OR BRANDS OF CHLORINE AN EXPLOSION CAN OCCUR.
5 Inline Chlorinator Chlorine Chemical Feeder Instructions Page 5 To oxidize 1 PPM of Hydrogen Sulfide (H2S), it takes 2.2 PPM of Chlorine (Cl2). To oxidize 1 PPM of Iron (Fe) it takes.64 PPM of (Cl2). Example: If you have a 4 PPM of Fe and 1 PPM of H2S, look on the vertical portion of the graph labeled PPM and start at 4 and move horizontal to the line marked Iron - Fe x.64 Cl2 and then down to the bottom of the graph marked Chlorine - Cl2 PPM. It should intercept the bottom at about 2.6. This is the amount of Cl2 needed to oxidize 4 PPM of Fe. Now look on the vertical portion of the graph labeled PPM and start at 1 and move horizontal to the line marked Hydrogen Sulfide - H2S x 2.2 Cl2 and then down to the bottom of the graph. It should intercept the bottom at about 2.2. This is the amount of Cl2 needed to oxidize 1 PPM of H2S. Example in dotted lines: 4 PPM Fe requires 2.6 PPM of Cl2. 1 PPM H2S requires 2.2 PPM of Cl2 Total Cl2 required is = 4.8 PPM Cl2 Higher PPM than the graph can be calculated. Example: 20 PPM H2S x 2.2 Cl2 = 44 PPM of Cl2 20 PPM Fe x.64 Cl2 = 12.8 PPM of Cl2 If using a 42 gallon pressure tank, the No. 2 hole on the chemical feeder should be used. This will dispense about 8PPM of Cl2, and a filter with 1 cube of activated carbon after the unit will eliminate the excess Cl2. If using the chemical feeder for iron removal or extremely high H2S, it is necessary to use a retention tank and a back washing valve on the carbon filter. The Chemical Feeder will hold about 4 lbs. of Cl2 (1 gram tablets). If it is adjusted to the No. 1 hole, and using a 42 gallon pressure tank with 1 cube of activated carbon, the system should process approximately 20,000 gallons of water before the unit would need refilling.
6 Inline Chlorinator Features ) Flow rate control 2) Large 1 1/2 in and out flow 3) Drain to release pressure or clean unit 4) Clearly labeled flow direction 5) Easy replacement of o-ring on lid Figure A
7 Tools and Materials needed 1) Pipe Cutters 2) PVC Glue 3) Two 1 ½ x 1 or 1 ½ x ¾ bushings - whichever your plumbing requires. 4) Two Ball Valves to cut off water supply. 5) One spigot to release pressure from system. (see Figure B) 6) One jug of chlorine pellets (available through Vitasalus/Equinox Products)
8 System Layout Well Pump Pressure Tank 1st Ball Valve Spigot 2nd Ball Valve Inline Chlorinator Figure B
9 Installing Chlorine Pellets 1. After checking that you have no leaks, you are now ready to add chlorine. 2. Turn the first and second ball valves to the off position. 3. Open spigot to relieve pressure from Inline Chlorinator Chlorine Pot Feeder. 4. Open Pot Feeder and close spigot. 5. Add Chlorine Pellets to Pot Feeder. 1. Close Pot Feeder turn ball valve back to the open position. Chlorine Dial Settings Problem Setting 1 ppm sulfur 1st notch 2-3 ppm sulfur 2nd notch 4-6 ppm sulfur 3rd notch.5-1 ppm iron 1st notch ppm iron 2nd notch ppm iron 3rd notch 3.5-up ppm iron 4th notch
10 Inline Chlorinator Maintenance 1. Turn the first and second ball valves to the off position. 2. Open spigot to relieve pressure from Inline Chlorinator Chlorine Pot Feeder. 3. Open Pot Feeder and close spigot. 4. Carefully clean the feeder tube with a pipe cleaner. 5. Add Chlorine Pellets to Pot Feeder. WARNING!! Do not mix brands of chlorine. Mixing brands may cause an explosion. 6. Close Pot Feeder turn ball valve back to the open position. 7. You will need to add chlorine to the system once every 2 to 3 months. 8. If the Inline Chlorinator clogs, you may need to clean it. To do so, Use a 5 gallon bucket and mix 3 parts water with 1 part Muriatic acid. 9. Soak JUST the Inline Chlorinator for 15 minutes. DO NOT put lid or o-rings in the solution. 10. Thoroughly rinse Inline Chlorinator in clean water. 11. Install the Inline Chlorinator back in line and let run for 20 minutes before adding chlorine.
Stenner Pump Chlorinator Installation & Start Up Guide
Clean Water Made Easy www.cleanwaterstore.com Stenner Pump Chlorinator Installation & Start Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance
Iron Air Charge 2510-SXT Installation & Start-Up Guide
Iron Air Charge 2510-SXT Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance your system will be providing iron free water
MODEL #320 - (* Using Bromine tablets with this device is not NSF certified)
RAINBOW CHLORINE/BROMINE* FEEDER MODEL #320 - (* Using Bromine tablets with this device is not NSF certified) Features: No special venting required. Completely enclosed-no escaping gases. Positive external
Maintenance Guide For Above Ground Pools
Maintenance Guide For Above Ground Pools Includes: General Operations/Overview......... page 2 The Five Keys to Pool Care............ page 2 Pump Operations............... page 3 Filter Operations...............
Troubleshooting a Greensand Plus filter system
110 Howell Rd. Suite A Post Office Box 664 Tyrone, Georgia 30290 Ph# (770) 487-1066 Fax (770) 487-2293 www.filtertechofgeorgia.com Revised: Nov. 2010 Troubleshooting a Greensand Plus filter system This
What To Do When Your Well is Flooded. Common Sense Steps To Take If Your Well Is Covered by Flood Water
What To Do When Your Well is Flooded Common Sense Steps To Take If Your Well Is Covered by Flood Water Courtesy of CleanWaterStore.com 2016 Contents 1. What To Do If Your Well Is Covered by Flood Water...
Water Treatment & Purification Chemicals
Lime-Out Extra Water Treatment Cleaning Chemicals Dissolves tough lime, calcium & rust stains Non-abrasive thick jelly like liquid clings to vertical surfaces Cleans tubs, sinks, shower doors, dishwashers
Owner s Manual. 5600 / 5600 Econominder
5600 / 5600 Econominder Owner s Manual For questions or in case of emergency, please call your local service technician (preferably the one who installed the system). Product Features, Benefits, & Job
Treatment options for hydrogen sulfide. Testing for hydrogen sulfide
Sometimes hot water will have a sour smell, similar to that of an old damp rag. This smell often develops when the thermostat has been lowered to save energy or reduce the potential for scalding. Odor-causing
Pro-OX 7800 Iron Filter Installation & Start-Up Guide
Clean Water Made Easy www.cleanwaterstore.com Pro-OX 7800 Iron Filter Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance
Understanding basic pool chemistry is one of the most important factors in pool maintenance. Properly balanced water creates an environment that
Understanding basic pool chemistry is one of the most important factors in pool maintenance. Properly balanced water creates an environment that optimizes the disinfection process and protects the pool
Adjusting Chemical Levels in a Swimming Pool
Adjusting Chemical Levels in a Swimming Pool When adding chemicals, there are three types of chemical adjustments that can be performed: product label chemical dosage, product label chemical adjustment,
Fiberstars Lighted Laminar Flow Fountain Installation Manual
Fiberstars Lighted Laminar Flow Fountain Installation Manual 79-15037-00 REV Xx http://www.fiberstars.com Page 1 of 8 SAVE THESE DIRECTIONS! These directions are provided to ensure the proper installation
POOL SUNSHINE IONIZER MODELS SPD, SPD2 AND SPS INSTALLATION INSTRUCTIONS
Sunshine Pool Products, LLC Manufacturer of Quality Pool & Spa Products 902 W 2010 S, Syracuse, Utah 84075 USA Voice: 801-825-4523 Website: www.sunshinepool.com Email: [email protected] POOL SUNSHINE
NITROUS TRANSFER PUMP INSTRUCTIONS
NITROUS TRANSFER PUMP INSTRUCTIONS SAFETY TIPS Never directly inhale nitrous oxide. When inhaled in large quantities, nitrous oxide can cause respiratory ailments or in extreme cases, death by suffocation.
MAINTAINING YOUR SPA WATER
MAINTAINING YOUR SPA WATER Tap water that is safe to drink is not always safe for a spa. Normal tap water is usually filled with minerals and microcontaminants that are not visible to the naked eye. Properly
Back Pack Sprayer. Operator's Manual MODELS MS - 40 MS - 50
Back Pack Sprayer Operator's Manual MODELS MS - 40 MS - 50 WARNING DANGER Read rules for safe operation and all instructions carefully. ECHO provides this Operator's Manual which must be read and understood
WATER CHEMISTRY AND POOL WATER BALANCE
C R6 H A PT E WATER CHEMISTRY AND POOL WATER BALANCE LEARNING OBJECTIVES After completely studying this chapter, you should be able to: Understand and list the parameters upon which water balance is based.
ETL listed for installations within 5 ft. (1.5M) of outer edge of water www.srsmith.com 79-15152-00 Rev E2 9.14 Page 1 of 10
Color Light Streams Large Laminar Installation Manual (CLSLL) Input Power: Total Power: 12V AC 5W 4008814 ETL listed for installations within 5 ft. (1.5M) of outer edge of water 79-15152-00 Rev E2 9.14
b. Alkalinity make your life easier and get the alkalinity between 80 and 120 PPM. c. ph from 7.2 and 7.8 so that the other chemicals work properly
1. Adding Chemicals to your water: Chemicals should be added slowly over a period of time. Pool owner/operators need to remember that all chemicals added will have an effect beyond their intended purpose.
Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation
Solar Pool Heating System Installation Manual Read the complete manual before beginning the installation 1. Sizing the System Visit www.techno-solis.com to size the system using the sizing calculator.
WARNING WARNING TABLE 1.
Clean & Clear Cartridge Filter Owners Manual IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Table of Contents SECTION I. FILTER INSTALLATION... 1 SECTION II. FILTER
Disinfecting Your Private Well
TCEQ GENERAL INFORMATION Water Supply Division GI-432 August 2013 Disinfecting Your Private Well Is Your Well Flooded? Disinfect It Before You Drink It! If your private well is flooded, do not use water
123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com MASTER MANUFACTURING MASTER GARDNER
123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com MASTER MANUFACTURING MASTER GARDNER Part Number PCD E3 009B MM Rev 1 Nov. 2010 INTRODUCTION The purpose of this manual
AKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS
AKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS Products Include: 60 gpm eductors Style 3060, 3061, 3062 & 3070 95 gpm eductors Style
Support Cleaning Apparatus. Operation, Cleaning, & Safety Manual
Support Cleaning Apparatus Operation, Cleaning, & Safety Manual Revision 1.1 31 May 2014 WARNING: The instructions and precautionary statements contained herein are intended for the Support Cleaning Apparatus
Fuel. What you will learn. Things you need before you start. Materials. Tools. When you have finished this module, you should be able to:
Fuel Student What you will learn When you have finished this module, you should be able to: Choose the right fuel for the engine Mix the right petrol and oil for a 2-stroke engine Know the main parts of
Scaletec Plus. Descaling Overview, Guidelines, Cleanup Tips, And Question & Answers
INFORMATION RELEASE Synergy Technology for Pool, Spa, & Fountains Scaletec Plus Product technical guidelines for calcium descaling and stain removal from swimming pool surfaces, tile, and equipment to
Easy as 1-2-3 instructions on how to install or replace the Cleanviro waterless urinal tablet
Easy as 1-2-3 instructions on how to install or replace the Cleanviro waterless urinal tablet 1. FOR NEW INSTALLATION, TURN OFF THE MAIN WATER SUPPLY OF THE URINAL AND DRAIN THE WATER TANK BY FLUSHING
Simply complete the enclosed Warranty Form with contact details, or email us with your details and date of purchase.
INSTALLATION & SERVICE GUIDE 4 STAGE UNDERSINK REVERSE OSMOSIS WITH SERVICE MODE Congratulations on your purchase of the most advanced Reverse Osmosis Water Purification system available. Part of our commitment
Cal Water 1961 Petra Lane, Placentia, CA 92870 (800) CAL-WATER (800) 225-9283 FAX: (714) 792-0794 http://www.cal-water.com
Industrial Water Purification MAINTAINING A STERILE HIGH PURITY WATER SYSTEM Introduction Maintaining a microbe free deionized water system is like trying to maintain a vacuum, and nature abhors a vacuum.
2 (. 3 4 5 . -,.. -,. 3. : 1 2 3 > 4, :!! 1,, 17 Lt MAX 2 3 4,, > 5.,,, 6 :, :1)! 2)! 7,, 1, :,. 2,, Bottom of steam generator 7 8 9 10 11 12 automatically and this phenomenon will continue for
Well and Water System Disinfection For Private Wells
Well and Water System Disinfection For Private Wells Minnesota Department of Health 625 North Robert Street, P.O. Box 64975 Environmental Health Division St. Paul, Minnesota 55164-0975 651-201-4600 or
FERTIGATION. Lawrence J. Schwankl
production FERTIGATION Lawrence J. Schwankl F ertigation is the injection of fertilizers through the irrigation system. Microirrigation systems are well-suited to fertigation because of their frequency
Fleck 7000 Softener Installation & Start-Up Guide
Clean Water Made Easy www.cleanwaterstore.com Fleck 7000 Softener Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance
8 plumbing. plumbing. 2010 PulteGroup, Inc. All Rights Reserved.
8 90 2010 PulteGroup, Inc. All Rights Reserved. drains All the water you use leaves the home through a drain. Maintaining drains prevents clogging, overflows, water damage, and other problems. care and
Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer
Overview READ ENTIRE INSTRUCTIONS BEFORE STARTING INSTALLATION PARTS LIST A. Flush valve B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve
CLEAN AND CLEAR PLUS CARTRIDGE FILTER
CLEAN AND CLEAR PLUS CARTRIDGE FILTER INSTALLATION AND USER S GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS i CUSTOMER SERVICE / TECHNICAL SUPPORT If you
Injection Systems INSTALLATION AND OPERATING GUIDE HI FLO VERTICAL SYSTEMS
1 TM INSTALLATION AND OPERATING GUIDE HI FLO VERTICAL SYSTEMS When the HI-FLO Metering Head is attached to a tank, the tank will be pressurized to the same pressure as the irrigation system. Before attaching
Metermatic SE Automatic Water Softener. Operation Manual
Metermatic SE Automatic Water Softener Operation Manual Page 7 of this manual contains important maintenance procedures for the continued proper operation of your unit. These MUST be performed regularly
COMPRESSED GASES. 1.2 The contents of each cylinder and container must be clearly identified (by tag or stamp) on the cylinder.
Page 1 of 5 COMPRESSED GASES A compressed gas is defined as any mixture of gases in a container with a pressure exceeding 40 psi. at 70 o F, or 104 psi. at 130 o F; or any flammable liquid with an absolute
Common Causes of High Water Bills
Common Causes of High Water Bills An unusually high water bill is most often caused by a leak or change in water use. Some common causes of high water bills include: A leaking toilet, or a toilet that
FLUSHMATE FLUSHMATE FLUSHOMETER - TANK SYSTEM. Owner s Service Manual 503 and 504 Series
Owner s Service Manual 503 and 504 Series FLUSHMATE FLUSHOMETER - TANK SYSTEM 503 504 FLUSHMATE A Division of Sloan Valve Company 30075 Research Drive New Hudson, MI 48165 800-533-3460 248-446-5300 http://www.flushmate.com
Parker Hannifin Corporation Process Advanced Filtration Division 2340 Eastman Avenue Oxnard, California 93030 USA
UF Cleaning Procedures 1 Formulas For Cationic (Cathodic) Paints Purpose Circ. Time Formulation(% by vol*) CC-1 Normal paint fouling 1-2 hours! 91.65% DI or RO Water 90-120 F! 3.0% Butyl Cellosolve! 5.0%
SunMaxx Solar Filling Station Operating Instructions
SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...
BF Series Sa S n u d p Fe i r l C t l e e r a n Installation Manual -1-
Installation Manual -1- What happens to the water in your pool? This should be a question of prime consideration for all pool owners. In the past some pools did not use filtering systems, the owner was
Aqua Rite & Aqua Rite XL Diagnostics Manual
Aqua Rite & Aqua Rite XL Diagnostics Manual Turbo Cell & Control Electronics Software Revision 1.58 Copyright 2011 Hayward Industries Inc. Leave Blank- Inside Front Cover Table of Contents Important safety
Hot Tub Start-up Guide
HOT TUB GUIDE Hot Tub Start-up Guide Connect to the electricity supply. Get a qualified electrician to do this, as you need a Part P certificate for your warranty and potentially for your home insurance.
Model MS-41BP 4G/ 15L. WARNING Carefully Read These Instructions Before Use 013529 R0514
Backpack Sprayer Use and Care Manual Model MS-41BP 4G/ 15L WARNING Carefully Read These Instructions Before Use 013529 R0514 WARNING WARNING: Improper use or failure to follow instructions can result in
Water System Disinfection
Water System Disinfection Document Number Revision 1 Approved By Ric Morris All 6/2/04 Active Divisions/Departments FEMC Raytheon Polar Services Company HARD COPY NOT CONTROLLED-CONTROLLED COPY AVAILABLE
ACID START-UP FOR POOL BUILDERS & SERVICE PROFESSIONALS
ACID START-UP FOR POOL BUILDERS & SERVICE PROFESSIONALS CONTENTS / INTRODUCTION INTRO 1 NEW PLASTER START-UP 2 COLOR PLASTER 4 FIBERGLASS POOL/SPA START-UP 6 VINYL POOL START-UP 8 COLOR & WHITE POOL PLASTER
Agricultural and Veterinary Chemicals Code (Listed Chemical Product Home Swimming Pool and Spa Products) Standard 2014
Agricultural and Veterinary Chemicals Code (Listed Chemical Product Home Swimming Pool and Spa Products) Standard 2014 I, Kareena Arthy, Chief Executive Officer of the Australian Pesticides and Veterinary
Voltmaster Trash Pumps Model TSP2, TSP3 and TSP4
Model TSP2, TSP3 and TSP4 Owner s Manual July 2010 Table of Contents 1 Introduction...................................................... 1 1.1 Read before using..............................................
FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL
FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL Congratulations on choosing the Fascination 700 HVLP Tanning Pro System! Your system includes the following items: 1 Fascination 700 HVLP Tanning Pro
Pro Logic Version 4.10. Diagnostics Manual
Pro Logic Version 4.10 Diagnostics Manual Turbo Cell & Control Electronics 2009 Hayward Industries Table of Contents Important safety instructions Pg. 1 No Cell Power 1 & No Cell Power 2 Pg. 2 No Cell
B150 Series Commercial Brewer. Direct Plumb Kit
B150 Series Commercial Brewer Welcome Keurig Authorized Dealer! Direct Plumb Kit This manual provides: Installation of the Direct Plumb Kit (DPK) that allows you to connect your customer s B150 brewer
1-888-448-7250 GENERAL CARE PLUMBING & VALVE INFORMATION TUB & SHOWER DOOR INFORMATION FOR QUESTIONS CALL OUR SERVICE DEPARTMENT
GENERAL CARE PLUMBING & VALVE INFORMATION TUB & SHOWER DOOR INFORMATION FOR QUESTIONS CALL OUR SERVICE DEPARTMENT 1-888-448-7250 or email [email protected] caring for your new bath fitter unit Thank
After the reactor has been running and the air in the chamber has been purged the co2 can be introduced and the dial in process can begin.
About Calcium Reactors: A calcium reactor is a device that dissolves calcium carbonate by using co2 gas to create an acidic condition within the reaction chamber. A circulation pump is used to move the
San josé OWNER S MANUAL
San josé OWNER S MANUAL Assembling & operating manual San josé 30 mbar - PORTABLE GAS BARBECUE 1. 2. 3. Improper installation, adjustment, alteration, service or maintenance can injury or property damage.
Engineering Recommendation on: Accumulators Revised 6-17-99 Issued January 10, 1979 Page 1 of 7
Issued January 10, 1979 Page 1 of 7 Accumulators have long been recognized by the industry as an effective means of maintaining good system balance by storing excess refrigerant as the condenser or evaporator
Basic Chemistry of Chlorination
Basic Chemistry of Chlorination Chlorine (Cl 2 ) is a gas, heavier than air, toxic, non-flammable and an economically available oxidizing agent that provides properties desirable in disinfection usage.
Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC
Portable Evaporative Air Cooler OWNER S MANUAL Read and save these instructions before use Model: CL30XC Power rating: 250 Watts Voltage rating: 230 Volt, 50Hz Made in P.R.C. QUICK START GUIDE Fill with
Fleck 4650. Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET
Fleck 4650 Service Manual TABLE OF CONTENTS JOB SPECIFICATION SHEET...1 INSTALLATION AND START-UP PROCEDURE...1 CONTROL VALVE DRIVE ASSEMBLY...2 CONTROL DRIVE ASSEMBLY FOR CLOCK...3 BYPASS VALVE ASSEMBLY...4
PRIVATE WATER SUPPLY - WATER SAFETY MAINTENANCE PLAN
PRIVATE WATER SUPPLY - WATER SAFETY MAINTENANCE PLAN WHY ROUTINE MAINTENANCE? Compared to the public water supply, private water supplies are more likely to be contaminated with bacteria, protozoa, viruses
123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com
123 Industrial Loop Road Paynesville, MN 56362 Phone: 1-800-864-1649 www.master-mfg.com INTRODUCTION The purpose of this manual is to assist you in the assembly, operation and maintenance of your sprayer
Installation Manual DIAPHRAGM WELL TANK
Installation Manual DIAPHRAGM WELL TANK IN-LINE SERIES: 2-5 & 7 GALLON VERTICAL SERIES: 14-20-25-32-36-52-65-86-96-119 GALLON HORIZONTAL SERIES: 7-14 & 20 GALLON NO LEAD NO LEAD: The weighted average of
Physical and Chemical Changes
Physical and Chemical Changes Jana Barrow West Point Jr. High 2775 W 550 N 801-402-8100 West Point, UT 84015 [email protected] Eighth Grade Integrated Science Standard I: Students will understand the
Rexroth Hydraulic Pump A10VO Series User Manual
Rexroth Hydraulic Pump A10VO Series User Manual Rexroth Hydraulic pump A10VO Series User Manual Revised 5/1/2009 Page 1 of 12 Functional Purpose This pump is preferred over a fixed displacement (gear)
Line to Refrigerator Ice/Water Dispenser
Standard 18 Line to Refrigerator Ice/Water Dispenser Pump Module Bottled Water How The System Works The FLOJET Bottled Water Dispensing System was designed to pump water from a commercially available 5-gallon
MC4-50 Feeding System
MC4-50 Feeding System Dry Calcium Hypochlorite For Municipal Applications The smarter way to water quality PATENTED SPRAY TECHNOLOGY DELIVERS UNPARALLELED CONSISTENT RESULTS The Constant Chlor Plus MC4-50
Indiana Department of Environmental Management. Well Disinfection
Indiana Department of Environmental Management www.in.gov/idem Well Disinfection Why Disinfect? Well disinfection can eliminate or reduce many different kinds harmful bacteria and viruses as well as harmless
CDS TROUBLESHOOTING SECTION I. VACUUM. 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg)
CDS TROUBLESHOOTING SECTION I. VACUUM 1.0. Weak vacuum at wand. Gauge reads normal (10hg to 14hg) 1.1. Clogged hoses or wand tube. Disconnect hoses and carefully check for an obstruction. 1.2. Excessive
Most agencies think about cleaning because of debris in the line.
Most agencies think about cleaning because of debris in the line. If we have an effective cleaning program there should not be a lot of debris in the line after the line is cleaned and tv d for acceptance.
INVERTER GENERATOR OWNER S MANUAL FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE.
INVERTER GENERATOR OWNER S MANUAL FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE. GENERATOR SAFETY EXHAUST GAS PRECAUTIONS Only use outdoors! Exhaust fumes can
PLUMBING CARE AND REPAIR
PLUMBING CARE AND REPAIR No special skills are required for any of the repairs described in this section. Plumbing repairs are seldom dangerous unless leaking water is soaking areas where there are electrical
Operator s Manual. PUMP Model: PAC25 SAVE THIS MANUAL FOR FUTURE REFERENCE. Distributed by: Pacer Pumps
Operator s Manual PUMP Model: PAC25 CAUTION: Before using this product, read this manual and follow all Safety Rules and Operating Instructions. SAVE THIS MANUAL FOR FUTURE REFERENCE Distributed by: Pacer
IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS
FNS Plus Vertical Grid D.E. Filter Owner's Manual IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Table of Contents SECTION I. FILTER INSTALLATION....1 SECTION II.
Home Drinking Water Treatment Systems
Home Drinking Water Treatment Systems Prepared by: Glenda M. Herman Extension Housing Specialist Gregory D. Jennings Extension Water Quality Specialist Published by: North Carolina Cooperative Extension
Watts Pure Water Systems
Watts Pure Water Systems WM-120-PT Installation and Operation Manual Premier Water Systems Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before
Tankless Water Heater
Tankless Water Heater USER S INFORMATION MANUAL Models WGRTNG199 / WGRTLP199 WGRTCNG199 / WGRTCLP199 NOTICE: Westinghouse reserves the right to make product changes or updates without notice and will not
Repair and Disinfection of Water Mains Water Protection Program fact sheet
Repair and Disinfection of Water Mains Water Protection Program fact sheet 9/2012 Every year waterborne disease outbreaks occur in the United States as a result of public water distribution system defi
Copper Meter Resetters
Copper Meter Resetters To Set 5/8", 5/8" x 3/4", 3/4", 1", 1 1 2" & 2" Water Meters 11/12 Table of Contents Page Page Meter Resetters 5/8", 5/8" x 3/4", 3/4", & 1" Horizontal Inlet and Outlet Series 710
Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS
Replacement parts DO NOT SERVICE THE BOILER WITHOUT A WM97+ MAINTENANCE KIT AVAILABLE Failure to adhere to these guidelines can result in severe personal injury, death or substantial property damage. The
EXPRESS STILL WARNING It is legal in New Zealand to own and operate a still for the purpose of producing alcohol for your own consumption.
THE EXPRESS STILL This still represents the next generation in home distillation equipment. It eliminates the problem of having to spend all day processing a 25 litre wash. Taking 1 hour to heat up, then
DO-IT-YOURSELF SEPTIC SYSTEM INSPECTION FIELD GUIDE (Mound System)
DO-IT-YOURSELF SEPTIC SYSTEM INSPECTION FIELD GUIDE (Mound System) Field Guide for homeowners to accompany the Do-It-Yourself Septic System Inspection 201 Course DISCLAIMER Septic system owners are ultimately
Guide to Common Water Quality Concerns
Guide to Common Water Quality Concerns The City of Corpus Christi Water Department's Water Quality Team understands the importance of safe drinking water for the health and well-being of our customers
Water Treatment Solutions for Residential & Light Commercial Applications
Water Treatment Solutions for Residential & Light Commercial Applications A quality water system manufactured by Petwa Ltd. will improve your water and benefit your home or office. Our systems feature
A HOMEOWNERS GUIDE ON-SITE SEWAGE MANAGEMENT SYSTEMS
GEORGIA DEPARTMENT OF HUMAN RESOURCES ENVIRONMENTAL HEALTH SECTION A HOMEOWNERS GUIDE TO ON-SITE SEWAGE MANAGEMENT SYSTEMS March 12, 2002 WHAT IS AN ON-SITE SEWAGE MANAGEMENT SYSTEM An on-site sewage management
Never use a spa or hot tub alone. Do not allow children to use a spa without supervision.
ASK THE EXPERT: SPA MAINTENANCE GUIDE By: All Seasons Spas & Fireplaces http://www.all4seasons.com Introduction Soaking in a hot tub or spa can be uniquely soothing and relaxing, but the hot water environment
OPL BASIC. Dosing System for Professional Laundry machines. Contents
OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page
Calcite PH Nutralizer System
Calcite PH Nutralizer System Installation, Operation & Maintenance Manual Facts About Calcite Ph Neutralizers Calcite is a crushed and screened white marble media which can inexpensively be used to neutralize
Cleaning Instructions, Pilot Replacement and Valve Change. Model No.: 233010 Natural Gas
Cleaning Instructions, Pilot Replacement and Valve Change Model No.: 233010 Natural Gas 8mm open-end wrench 9mm open-end wrench 10mm open-end wrench 12mm open-end wrench 13mm open-end wrench Phillips screw
01 - Plastic Pipe Cements and Primers
01 - Plastic Pipe Cements and Primers Q - What is the shelf life of the cement and primers? PVC & ABS Cements / Primers and Cleaners have 3 year shelf life from date of manufacture, and CPVC has 2 year
Operator Quick Guide EC SENSOR
Operator Quick Guide EC SENSOR Revision G - 24/04/2008 General Information About This Guide The information in this guide has been carefully checked and is believed to be accurate. However, Hach Ultra
Overheating limit control
Pahlén electric heater Maxi Heat with digital control is a compact and effective heater for swimming pools. It consists of a glassfibre reinforced polypropylene tank containing resistance-type heating
detection kit the water leak water leaks: What you should know A helpful guide for locating indoor and outdoor water leaks Getting Ready
water leaks: What you should know the water leak detection kit Imagine that the dot inside these brackets [ ] is the only hole in your home s water system. By its size alone, that hole may not seem worth
Bio-Clean. for Septic Systems. Tips for Using Bio-Clean. Page Index METRIC CONVERSIONS
Bio-Clean for Septic Systems METRIC CONVERSIONS 1 tablespoon = 15ml 1/4 cup = 57 ml 1/3 cup = 76 ml 1/2 cup = 114 ml 1 pint = 1/2 litre 1 quart = 1 litre 1/2 gallon = 2 litres 1 gallon = 4 litres 1 pound
Septic Tank to Cistern Conversions. Saving Water & Saving Money
Florida Keys Aqueduct Authority 1100 Kennedy Drive Key West, Florida 33040 Septic Tank to Cistern Conversions Saving Water & Saving Money One of the benefits of connecting to the Central Wastewater System
FILLING AND PURGING THE SYSTEM
FILLING INSTRUCTIONS FOR WATER HEATER OR CONDENSING BOILER (City Water) Safety tip: Before beginning, turn off power to boiler and circulator. FILLING AND PURGING Step 1: Close Return Manifold Isolation