Collection of Datasheets. Direct Current Compressors R134a 12-24V 10-45V (Solar) R600a 10-45V (Solar) REFRIGERATION AND AIR CONDITIONING
|
|
- Karen Farmer
- 7 years ago
- Views:
Transcription
1 ollection of atasheets irect urrent ompressors R1a 1V 1V (Solar) Ra 1V (Solar) REFRIGERATION AN AIR ONITIONING
2 ontents General Page Electric circuit Wiring diagram Voltage range able dimensions Thermostat connection ompressor speed Fan connection Troubleshooting LE connection Protection systems BF Technical data Performance data 7 BF Technical data (inch connectors) 8 (inch) Performance data (inch connectors) 9 BF Technical cata 1 Performance data 11 BF Technical data (with inch connectors) 1 (inch) Performance data (with inch connectors) 1 B8F Technical data 1 Performance data 1 BF Technical data (for solar applications) 1 (solar) Performance data (for solar applications) 17 BK Technical data (for solar applications) 18 (solar) Performance data (for solar applications) 19 ata stamping Mounting the electronic unit 1 onnectors Mounting accessories Filter drier selection Sectional view General anfoss variable speed refrigeration compressors type BF, BF and B8F are designed for connection to 1V and V power supply and for refrigerant R1a (F H F). The compressors are intended especially for use in mobile applications, e.g. cooling boxes, boats, caravans, trucks, vans, buses, etc. ue to their low energy consumption and the option for a wide supply voltage range, the compressors are also very suitable for stationary applications powered by photovoltaic solar panels. The compressors can be used in refrigerators and freezers designed for capillary tube and TEV as the throttling device. The BK is especially designed for refrigeration systems using isobutane, refrigerant Ra ( H 1 ). Ra is classified as a flammable refrigerant of class A according to ANSI/ASHRAE. Accordingly, special safety regulations must be complied with. For domestic appliances a special Test Schedule has been integrated in the European Standard EN and IE. For commercial refrigerators IE 89 will include flammable refrigerants. The BK must only and exclusively be used in appliances certified for Ra according to these or later regulations. This means that the compressors must not be used in appliances which are not originally designed and certified for Ra. This compressor was designed for stationary use only. The B compressor concept includes an electronic unit which features overload protection and battery protection. The electronic unit has internal voltage recording and calibration to the applied voltage. The electronic unit may also be powered directly from certain types of electronic power supply units and thus no battery is required. In addition to being especially quiet in operation, the compressors have a high OP value. They will operate under continual heeling of such as occurs on boats. The B compressors must be mounted in a dry and clean place. The compressors will withstand storage temperatures down to. ondensing temperatures: Max. at stable conditions and max. 7 at peak load. Ambient temperatures: Min., max. K..7. May
3 Electric circuit The B compressors are fitted with a brushless direct current motor which is electronically commutated by an electronic unit. The electronic unit is delivered separately and must be mounted on the compressor, please see instructions page. The electronic unit must always be connected directly to the battery poles or power supply unit terminals. For the protection of the installation an external fuse must be installed in the power supply cable close to the battery or power supply unit. Establish a special wiring for the B power supply using direct onepiece cables and avoid to use the existing wiring. If the chassis is used as a conductor, a proper connection between cable and chassis must be established. Wrong polarity applied to the electronic unit does not destroy the unit, however, the compressor does not work. If the compressor is planned to be stopped for a longer period, a main switch can be installed. The switch must have a contact system rated min. A, otherwise the voltage drop over the contacts will cause the battery protection to cut off the compressor earlier than intended. Wiring diagram BF / BF BK / BF Solar F 1 P T F 1 T B8F F P T : Electronic unit : Battery / Solar Panel : Fuse : Main switch (optional) : Fan (optional) : LE Light Emitting iode (optional) 7: Thermostat 8: Resistor for presetting speed (optional) 9: Resistor for presetting battery protection voltage (optional) 81 Voltage range B//8F: 1V systems: From 1.V (9.V) to 17V; V systems: From.8V (1.V) to V. BF/BK: Solar systems: 1V V The low voltage limits stated in brackets () can be established if a connection is made between the terminals and P, please see also the passage Optional battery protection settings page. The electronic unit will calibrate to the applied voltage. This means that if the battery voltage is less than 17V, the electronic unit assumes that it is working in a 1V system. If the voltage is higher than 17V, the electronic unit assumes that it is working in a V system. onsequently, the compressor does not run at power supply voltages between about 17V and the desired battery protection cutout voltage for V systems. A continuous voltage range from 9.V to V can be established if a kω resistor (wiring diagram item 9) is connected between the terminals and P. This wide voltage range makes the B compressors very suitable for photovoltaic powering. able dimensions To ensure correct start and operating conditions, the following cable dimensions must be observed: BF / BF / BK Solar / BF Solar B8F ross section mm m 1V operation m V operation ross section mm m 1V operation m V operation *Length between battery and electronic unit May K..7.
4 Thermostat connection B compressors can operate with normal mechanical type thermostats as used in refrigeration appliances, or with electronic thermostats. Always use new thermostats. The thermostat is connected between the terminals and T of the electronic unit. The compressor current does not flow through the thermostat contacts. When the thermostat is cut out there will still be power on to the electronic unit. A system with no standby power consumption can be established if the thermostat (7) is replaced by a jumper between the terminals and T, and the main switch () is replaced by a thermostat. In this case the full current to the compressor flows through the thermostat, which must be rated accordingly. ompressor speed Without any resistor in the control circuit, the compressor will run with a fixed speed of rpm when the thermostat is switched on, depending on the electronic unit version (see tables below). Other fixed speeds in the range between and /,rpm can be obtained when a resistor (8) is installed to adjust the current (ma) of the contol circuit, please see wiring diagrammes page. In AEO (Adaptive Energy Optimizing) speed mode the B compressor will always adapt its speed to the actual cooling demand. BF / BF Electronic unit 11N1 11N 11N with AEO Resistor R1 (8) Ω speed rpm AEO ontr.circ. current ma B8F Electronic unit 11N8 with AEO BF Solar / BK Solar Electronic unit 11N with AEO Resistor R1 (8) Ω Resistor R1 (8) Ω speed rpm AEO,1,8, speed rpm AEO ontr.circ. current ma ontr.circ. current ma LE connection A 1mA Light Emitting iode (LE) for compressor operation monitoring can be connected between the terminals and. Operational errors will cause the LE to flash a number of times. The number of flashes depends on what kind of operational error was recorded. Each flash will last ¼ second. After the actual number of flashes there will be a delay with no flashes, so that the sequence for each error recording is repeated every seconds. Operational errors shown by LE (optional): BF / BF / BK Solar / BF Solar Number of flashes Error type Thermal cutout of electronic unit (If the refrigeration system has been too heavily loaded, or if the ambient temperature is high, the electronic unit will run too hot). Minimum motor speed error (If the refrigeration system is too heavily loaded, the motor cannot maintain minimum speed at approximately 1,8 rpm). start error (The rotor is blocked or the differential pressure in the refrigeration system is too high (> bar)). Fan overcurrent cutout (The fan loads the electronic unit with more than 1A peak ). B8F Number of flashes Error type Thermal cutout of electronic unit (If the refrigeration system has been too heavily loaded, or if the ambient temperature is high, the electronic unit will run too hot). Minimum motor speed error (If the refrigeration system is too heavily loaded, the motor cannot maintain minimum speed at approximately, rpm). start error (The rotor is blocked or the differential pressure in the refrigeration system is too high (> bar)). Fan overcurrent cutout (The fan loads the electronic unit with more than 1A peak ). 1 Battery protection cutout (The voltage is outside the cutout setting). 1 Battery protection cutout (The voltage is outside the cutout setting). K..7. May
5 Fan connection If a fan is to be used, it must be connected to the electronic unit terminals and F. Always use a 1V fan, also in V systems, as the electronic unit will automatically reduce the applied voltage to 1V for the fan. Using the special solar electronic unit 11N, the fan runs with input voltage always. The max. load on the electronic unit is.a average or 1A peak. The fan is allowed to start with a higher current for the first seconds. If the fan becomes overloaded, both fan and compressor will be cut out by the overload protection. Troubleshooting To diagnose why a compressor comes to an unintended stop, it is recommended to have a Light Emitting iode (LE) installed between the terminals and, please see page and. Provided that the electronic unit is properly connected to the power supply, and the thermostat is on, the number of flashes emitted by the LE will give a hint about the reason for the interruption of the compressor operation. The motor windings can be checked for defects by measuring the resistance between the current leadin pins. If the measured values between all pins are approximately the same, the motor is most likely all right. The electronic unit is not to be repaired, it should not be opened at all. Protection systems Overload protections Voltage protection Battery protection (BF / BF / B8F) The B compressor protection system facilitates protection against compressor overload and start failure, fan overload and electronic unit overheating as well as destructive battery discharge. When an overload protection is activated, the compressor enters a cycle in which it makes start attempts at about seconds intervals until a successfull start is achieved. The compressor overload and start protection cuts off power to the compressor if the compressor speed drops below approximately 1,8 rpm (BF/BF/BK) or, rpm (B8F) or this motor speed is not reached during the start sequence. Possible reasons for overload protection activating could be excess refrigeration system pressures during operation or too high pressure difference. The fan overload protection stops the compressor and fan if the fan current exceeds.a average or 1A peak. An overheating of the electronic unit heat sink will cause the compressor to stop. Restart will occur automatically when the temperature has dropped. If a fan is installed, it will continue to run if the compressor stops due to overload or electronic unit overheating. If a voltage outside the specified range is applied to the electronic unit, the compressor does not start, or it stops if the voltage limit is exceeded during operation. The compressor will restart automatically about 1 minute after the supply voltage has reached the reset voltage within the range in question. If a fan is installed, it will start to operate without a delay as soon as the reset voltage is reached. To ensure sufficient battery power for proper compressor operation or to avoid permanent damage to the battery because of heavy discharge, the B electronic unit facilitates also a battery protection. The compressor is stopped and restarted again according to the decided voltage limits measured on the and terminals of the electronic unit. Standard battery protection settings 1V cutout 1V cutin V V V cutout V.8 V cutin V. Other battery protection settings are optional if a connection, which includes a resistor, is established between terminals and P, please see the wiring diagram page. Optional battery protection settings Resistor (R9) kω V cutout V V cutin V V max. voltage V cutout V V cutin V V max. voltage May K..7.
6 BF irect urrent ompressor R1a 1 V ata Sheet (Replaces..A7.) ode numbers BF without electronic unit 11Z Electronic unit 1V standard single: 11N1, pcs: 11N11 Electronic unit 1V w. metal shielding single: 11N, pcs: 11N1 Electronic unit 1V with AEO single: 11N, pcs: 11N1 LBP/MBP/(HBP) Evaporating temperature range to (1) Voltage range / max. voltage 1 V / V Max. machine compartment temperature omp. cooling at ambient temp. S or F 1 * esign * depending on application isplacement cm. Oil quantity cm 1 Maximum refrigerant charge g Free gas vol. in compressor cm 87 Weight: ompressor/electronic unit kg./. type Variable speed Resistance, all windings ( ) Ω. Approvals E 7/ 9/ 77, UL98, SA. imensions Height mm A 17 B 1 B1 18 B 7 Suction connector location/i.. mm. ±.9 Process connector location/i.. mm. ±.9 ischarge connector location/i.. mm E..1/. ompressors on a pallet pcs. 1 Standard battery protection settings (no connection P) 1V cutout 1. 1V cutin 11.7 V cutout.8 V cut in. Optional battery protection settings Resistor (R) [kω] V cutout V cutin V max. Voltage V cutout V cutin V max. Voltage April..A8. 1 ø Blue stripe 8 BF Barcode on white background Grey background S O F 1 F 1 R1a e 77 E approval mark (electronic unit) ø N Z MAE IN GERMANY = Static cooling normally sufficient = Oil cooling = Fan cooling 1. m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling. m/s necessary B 7 1 R BF 1/V THERMALLY PROTETE SYSTEM Approval mark B ø9 E B A 89 1 K..7. May
7 apacity (EN 19/EOMAF) apacity (ASHRAE) Power consumption urrent consumption (for V applications the following must be halved) A OP (EN 19/EOMAF) W/W OP (ASHRAE) W/W Test conditions EN 19/EOMAF ASHRAE ondensing temperature Ambient and suction gas temp. Liquid temperature Static cooling, 1V 1 Watt =.8 kcal/h Accessories ompressor speed Electronic unit 11N1 11N 11N with AEO Resistor (R1) Ω speed rpm AEO ontr.circ. current ma In AEO (Adaptive Energy Optimizing) speed mode the B compressor will always adapt its speed to the actual cooling demand. evices BF Standard automobile fuse Not IN 78 1V: 1A deliverable V: 7.A from anfoss Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap on in quantities Wire dimensions Size AWG ross section Gauge mm V operation ft. m V operation ft. m *Length between battery and electronic unit Power supply Fuse LE Thermostat Terminal plug Main switch R1 Fan R 8 F P T Operational errors shown by LE (optional) Number Error type of flashes Thermal cutout of electronic unit (If the refrigeration system has been too heavily loaded, or if the ambient temperature is high, the electronic unit will run too hot). Minimum motor speed error (If the refrigeration system is too heavily loaded, the motor cannot maintain minimum speed at approximately 1,8 rpm). start error (The rotor is blocked or the differential pressure in the refrigeration system is too high (> bar)). Fan overcurrent cutout (The fan loads the electronic unit with more than 1A peak ). 1 Battery protection cutout (The voltage is outside the cutout setting)...a8. April May K..7. 7
8 BF (Inch onnectors) irect urrent ompressor R1a, 1 V Resistor (R) [kω] V cutout V cutin V max. Voltage ata Sheet (Replaces..1.) ode numbers BF without electronic unit 11Z Electronic unit 1V standard single: 11N1, pcs: 11N11 Electronic unit 1V w. metal shielding single: 11N, pcs: 11N1 Electronic unit 1V with AEO single: 11N, pcs: 11N1 LBP/MBP/ [HBP] Evaporating temperature range F ( ) to [] ( to [1]) Voltage range / max. voltage 1 V / V Max. machine compartment temp. F ( ) 11 () omp. cooling at ambient temp. 11 F ( ) S or F 1 * esign * depending on application isplacement cu.in. (cm ).1 (.) Oil quantity fl.oz. (cm ).1 (1) Maximum refrigerant charge oz. (g) 1. () Free gas vol. in compressor fl.oz. (cm ) 9. (87) Weight: ompressor/electronic unit lbs. (kg) 9./. (./.) type Variable speed Resistance, all windings (77 F) Ω. Approvals (electronic unit) E 7/ 9/ 77, UL98, SA. imensions Height in. (mm) A.9 (17) B. (1) B1. (18) B.87 (7) Suction connector location/i.. in. (mm)..9 (.±.9) Process connector location/i.. in. (mm)..9 (.±.9) ischarge connector location/i.. in. (mm) E.. (..1/.) ompressors on a pallet pcs. 1 Standard battery protection settings (no connection P) 1V cutout 1. 1V cutin 11.7 V cutout.8 V cut in. Optional battery protection settings V cutout V cutin V max. Voltage Blue stripe ø."(1) April "(1).7"(1) S O F 1 F 1.1" (8).79"().9"(78.) = Static cooling normally sufficient = Oil cooling = Fan cooling 1. m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling. m/s necessary BF Barcode on white background Grey background R1a e 77 E approval mark (electronic unit).8"(1) 81."(17) 7.91"(1) 8."().7"(17) ø.17"(.) N Z MAE IN GERMANY."(1) 1.81" () B R BF 1/V THERMALLY PROTETE SYSTEM Approval mark."(9) B1.7"(7) E B A.9"(1).1"(1) 89 ø."(9) 8 K..7. May
9 apacity (ASHRAE) Btu/h rpm \ F apacity (EN 19/EOMAF) rpm \ F In AEO (Adaptive Energy Optimizing) speed mode the B compressor will always adapt its speed to the actual cooling demand. Terminal plug Power consumption rpm \ F Fuse Main switch urrent consumption (for V applications the following must be halved) A Power supply Fan LE rpm \ F 1 1 F R1 P Thermostat R T EER (ASHRAE) Btu/Wh rpm \ F Test conditions ASHRAE EN ondensing temperature 1 F (, ) (11 F) Ambient & suction gas temp. 9 F ( ) (9 F) Liquid temperature 9 F ( ) (11 F) OP (EN 19/EOMAF) W/W Static cooling, 1V rpm \ F Watt =.1 Btu/h =.8 kcal/h Operational errors shown by LE (optional) Number Error type of flashes Wire dimensions Thermal cutout of electronic unit Size (If the refrigeration system has been too heavily loaded, or if the ambient temperature is ompressor speed AWG 1V operation V operation high, the electronic unit will run too hot). Electronic unit 11N1 11N 11N with AEO Resistor (R1) Ω speed rpm AEO ontr.circ. current ma ross section Gauge mm *Length between battery and electronic unit Accessories evices ft. m ft. m BF Standard automobile fuse Not IN 78 1V: 1A deliverable V: 7.A from anfoss Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap on in quantities Minimum motor speed error (If the refrigeration system is too heavily loaded, the motor cannot maintain minimum speed at approximately 1,8 rpm). start error (The rotor is blocked or the differential pressure in the refrigeration system is too high (> bar)). Fan overcurrent cutout (The fan loads the electronic unit with more than 1A peak ). 1 Battery protection cutout (The voltage is outside the cutout setting).... April May K..7. 9
10 BF irect urrent ompressor R1a 1 V ata Sheet (Replaces..B.) ode numbers BF without electronic unit 11Z1 Electronic unit 1V standard single: 11N1, pcs: 11N11 Electronic unit 1V w. metal shielding single: 11N, pcs: 11N1 Electronic unit 1V with AEO single: 11N, pcs: 11N1 LBP/MBP/(HBP) Evaporating temperature range to (1) Voltage range / max. voltage 1 V / V Max. machine compartment temperature omp. cooling at ambient temp. S or F 1 * esign * depending on application isplacement cm. Oil quantity cm 1 Maximum refrigerant charge g Free gas vol. in compressor cm 87 Weight: ompressor/electronic unit kg./. type Variable speed Resistance, all windings ( ) Ω. Approvals (electronic unit) E 7/ 9/ 77, UL98, SA. imensions Height mm A 17 B 1 B1 18 B 7 Suction connector location/i.. mm. ±.9 Process connector location/i.. mm. ±.9 ischarge connector location/i.. mm E..1/. ompressors on a pallet pcs. 1 Standard battery protection settings (no connection P) 1V cutout 1. 1V cutin 11.7 V cutout.8 V cut in. Optional battery protection settings Resistor (R) [kω] V cutout V cutin V max. Voltage V cutout V cutin V max. Voltage April..B. 1 ø1 1 1 Barcode on white background Grey background 78. Blue stripe S O F 1 F 8 BF 1 R1a e 77 E approval mark (electronic unit) ø N Z 1 MAE IN GERMANY = Static cooling normally sufficient = Oil cooling = Fan cooling 1. m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling. m/s necessary B 7 1 R BF 1/V THERMALLY PROTETE SYSTEM Approval mark B ø9 E B A K..7. May
11 apacity (EN 19/EOMAF) * 178* * 181* * 171* * 19* apacity (ASHRAE) * 1* * * * 1* * 19* Power consumption * 8.* * 9.1* * 1* * 19* urrent consumption (for V applications the following must be halved) A *.9* * 7.8* * 8.* * 9.* OP (EN 19/EOMAF) W/W *.1* * 1.88* * 1.* * 1.* OP (ASHRAE) W/W *.* *.* *.* * 1.8* Test conditions EN 19/EOMAF ASHRAE ondensing temperature Ambient and suction gas temp. Liquid temperature Static cooling, 1V * Fan cooling of electronic unit compulsory Accessories 1 Watt =.8 kcal/h evices ompressor speed Electronic unit 11N1 11N 11N with AEO Resistor (R1) Ω speed rpm AEO ontr.circ. current ma In AEO (Adaptive Energy Optimizing) speed mode the B compressor will always adapt its speed to the actual cooling demand. BF Standard automobile fuse Not IN 78 1V: 1A deliverable V: 7.A from anfoss Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap on in quantities Wire dimensions Size AWG ross section Gauge mm V operation ft. m V operation ft. m *Length between battery and electronic unit Power supply Fuse LE Thermostat Terminal plug Main switch R1 Fan R 8 F P T Operational errors shown by LE (optional) Number Error type of flashes Thermal cutout of electronic unit (If the refrigeration system has been too heavily loaded, or if the ambient temperature is high, the electronic unit will run too hot). Minimum motor speed error (If the refrigeration system is too heavily loaded, the motor cannot maintain minimum speed at approximately 1,8 rpm). start error (The rotor is blocked or the differential pressure in the refrigeration system is too high (> bar)). Fan overcurrent cutout (The fan loads the electronic unit with more than 1A peak ). 1 Battery protection cutout (The voltage is outside the cutout setting)...b. April May K
12 BF (Inch onnectors) irect urrent ompressor R1a, 1 V Resistor (R) [kω] V cutout V cutin V max. Voltage ata Sheet (Replaces..1.) ode numbers BF without electronic unit 11Z Electronic unit 1V standard single: 11N1, pcs: 11N11 Electronic unit 1V w. metal shielding single: 11N, pcs: 11N1 Electronic unit 1V with AEO single: 11N, pcs: 11N1 LBP/MBP/ [HBP] Evaporating temperature range F ( ) to [] ( to [1]) Voltage range / max. voltage 1 V / V Max. machine compartment temp. F ( ) 11 () omp. cooling at ambient temp. 11 F ( ) S or F 1 * esign * depending on application isplacement cu.in. (cm ).1 (.) Oil quantity fl.oz. (cm ).1 (1) Maximum refrigerant charge oz. (g) 1. () Free gas vol. in compressor fl.oz. (cm ) 9. (87) Weight: ompressor/electronic unit lbs. (kg) 9./. (./.) type Variable speed Resistance, all windings (77 F) Ω. Approvals (electronic unit) E 7/ 9/ 77, UL98, SA. imensions Height in. (mm) A.9 (17) B. (1) B1. (18) B.87 (7) Suction connector location/i.. in. (mm)..9 (.±.9) Process connector location/i.. in. (mm)..9 (.±.9) ischarge connector location/i.. in. (mm) E.. (..1/.) ompressors on a pallet pcs. 1 Standard battery protection settings (no connection P) 1V cutout 1. 1V cutin 11.7 V cutout.8 V cut in. Optional battery protection settings V cutout V cutin V max. Voltage Blue stripe ø."(1) April "(1).7"(1) S O F 1 F 1.1" (8).79"().9"(78.) BF Barcode on white background Grey background R1a e 77 E approval mark (electronic unit).8"(1) 81 = Static cooling normally sufficient = Oil cooling = Fan cooling 1. m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling. m/s necessary."(17) 7.91"(1) 8."().7"(17) ø.17"(.) N Z MAE IN GERMANY."(1) 1.81" () B R BF 1/V THERMALLY PROTETE SYSTEM Approval mark."(9) B1.7"(7) E B A.9"(1).1"(1) 89 ø."(9) 1 K..7. May
13 apacity (ASHRAE) Btu/h rpm \ F * 97* * 89* * 8* 17 1* 79* apacity (EN 19/EOMAF) rpm \ F * 1* * 191* * * * 187* In AEO (Adaptive Energy Optimizing) speed mode the B compressor will always adapt its speed to the actual cooling demand. Terminal plug Power consumption rpm \ F * 8.* * 98.* Fuse Main switch * 98.9* 119* 111* urrent consumption (for V applications the following must be halved) A Power supply Fan LE rpm \ F 1 1 F * 7.9* * 8.* R1 P * 9.* Thermostat R T * 9.91* EER (ASHRAE) Btu/Wh rpm \ F * 8.9* Test conditions ASHRAE EN * 8.1* ondensing temperature 1 F (, ) (11 F) * 7.7* Ambient & suction gas temp. 9 F ( ) (9 F) *.* Liquid temperature 9 F ( ) (11 F) Static cooling, 1V OP (EN 19/EOMAF) W/W * Fan cooling of electronic unit compulsory rpm \ F Watt =.1 Btu/h =.8 kcal/h * 1.9* * 1.9* Operational errors shown by LE (optional) * 1.8* Number Error type * 1.* of flashes Wire dimensions Thermal cutout of electronic unit Size (If the refrigeration system has been too heavily loaded, or if the ambient temperature is ompressor speed AWG 1V operation V operation high, the electronic unit will run too hot). Electronic unit 11N1 11N 11N with AEO Resistor (R1) Ω speed rpm AEO ontr.circ. current ma ross section Gauge mm *Length between battery and electronic unit Accessories evices ft. m ft. m BF Standard automobile fuse Not IN 78 1V: 1A deliverable V: 7.A from anfoss Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap on in quantities Minimum motor speed error (If the refrigeration system is too heavily loaded, the motor cannot maintain minimum speed at approximately 1,8 rpm). start error (The rotor is blocked or the differential pressure in the refrigeration system is too high (> bar)). Fan overcurrent cutout (The fan loads the electronic unit with more than 1A peak ). 1 Battery protection cutout (The voltage is outside the cutout setting).... April May K..7. 1
14 B8F irect urrent ompressor R1a 1 V ode numbers B8F without electronic unit Electronic unit 1V standard ata Sheet (Replaces (..F1.) 11Z8 single: 11N8, 8 pcs: 11N81 B8F 11Z LBP Evaporating temperature range to Voltage range / max. voltage 1 V / V Max. machine compartment temperature omp. cooling at ambient temp. S or F 1 * esign * depending on application isplacement cm. Oil quantity cm 1 Maximum refrigerant charge g Free gas vol. in compressor cm 87 Weight: ompressor/electronic unit kg./. Blue stripe Barcode on white background Grey background S O F 1 F R1a N MAE IN GERMANY e 77 E approval mark = Static cooling normally sufficient = Oil cooling = Fan cooling 1. m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling. m/s necessary type Variable speed Resistance, all windings ( ) Ω. Approvals (electronic unit) E 7/ 9/ imensions Height mm A 17 B 1 B1 18 B Suction connector location/i.. mm. ±.9 Process connector location/i.. mm. ±.9 ischarge connector location/i.. mm E..1/. ø1 ø. 17 ø9 E ompressors on a pallet pcs. 1 Standard battery protection settings (no connection P) 1V cutout 1. 1V cutin 11.7 V cutout.8 V cut in. Optional battery protection settings Resistor (R) [kω] V cutout V cutin V max. Voltage V cutout V cutin V max. Voltage B1 B 1 9 B A 89 1 May..F. 1 1 K..7. May
15 apacity (EN 19/EOMAF) , , , apacity (ASHRAE) , , , Power consumption , , , urrent consumption (for V applications the following must be halved) A , , , OP (EN 19/EOMAF) W/W , , , OP (ASHRAE) W/W , , , Test conditions EN 19/EOMAF ASHRAE ondensing temperature Ambient and suction gas temp. Liquid temperature Static cooling, 1V Fan cooling of electronic unit integrated 1 Watt =.8 kcal/h ompressor speed Electronic unit 11N8 with AEO Resistor (R1) Ω speed rpm AEO,1,8, ontr.circ. current ma In AEO (Adaptive Energy Optimizing) speed mode the B compressor will always adapt its speed to the actual cooling demand. Wire dimensions ross section mm m 1V operation. m V operation *Length between battery and electronic unit Accessories evices B8F Standard automobile fuse Not IN 78 1V: A deliverable V: 1A from anfoss Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap on in quantities Power supply Fuse LE Thermostat Terminal plug Main switch R1 Fan R 8 F P T Operational errors shown by LE (optional) Number Error type of flashes Thermal cutout of electronic unit (If the refrigeration system has been too heavily loaded, or if the ambient temperature is high, the electronic unit will run too hot). Minimum motor speed error (If the refrigeration system is too heavily loaded, the motor cannot maintain minimum speed at approximately, rpm). start error (The rotor is blocked or the differential pressure in the refrigeration system is too high (> bar)). Fan overcurrent cutout (The fan loads the electronic unit with more than 1A peak ). 1 Battery protection cutout (The voltage is outside the cutout setting)...f. May May K..7. 1
16 BF irect urrent ompressor for Solar s R1a 1 V ata Sheet ode numbers BF without electronic unit 11Z1 Electronic unit 1V single: 11N, pcs: 11N1 LBP/MBP/(HBP) Evaporating temperature range to (1) Voltage range / max. voltage 1 V Fan output same as input voltage Max. machine compartment temperature omp. cooling at ambient temp. S or F 1 * * depending on application esign isplacement cm. Oil quantity cm 1 Maximum refrigerant charge g Free gas vol. in compressor cm 87 Weight: ompressor/electronic unit kg./. Blue stripe BF Barcode on white background Grey background S O F 1 F R1a 17 N Z 1 MAE IN GERMANY e 77 E approval mark = Static cooling normally sufficient = Oil cooling = Fan cooling 1. m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling. m/s necessary type Variable speed Resistance, all windings ( ) Ω Approvals (electronic unit) E 7/ 9/ 77 imensions Height mm A 17 B 1 B1 18 B 7 Suction connector location/i.. mm. ±.9 Process connector location/i.. mm. ±.9 ischarge connector location/i.. mm E..1/. ompressors on a pallet pcs. 1 ø1 1 ø B1 B 1 ø9 E B A July..E K..7. May
17 apacity (EN 19/EOMAF) apacity (ASHRAE) Power consumption urrent consumption (for V applications the following must be halved) A OP (EN 19/EOMAF) W/W OP (ASHRAE) W/W Test conditions EN 19/EOMAF ASHRAE ondensing temperature Ambient and suction gas temp. Liquid temperature Static cooling, 1V 1 Watt =.8 kcal/h Accessories ompressor speed Electronic unit 11N with AEO Resistor (R1) Ω speed rpm AEO ontr.circ. current ma In AEO (Adaptive Energy Optimizing) speed mode the B compressor will always adapt its speed to the actual cooling demand. evices BF Standard automobile fuse Not IN 78 1A deliverable from anfoss Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap on in quantities Wire dimensions Size AWG ross section Gauge mm V operation ft. m ft. m *Length between battery and electronic unit V operation Fuse LE Thermostat Terminal plug Main switch R1 Solar panel Fan 8 F Operational errors shown by LE (optional) Number of flashes Error type Thermal cutout of electronic unit (If the refrigeration system has been too heavily loaded, or if the ambient temperature is high, the electronic unit will run too hot). Minimum motor speed error (If the refrigeration system is too heavily loaded, the motor cannot maintain minimum speed at approximately 1,8 rpm). start error (The rotor is blocked or the differential pressure in the refrigeration system is too high (> bar)). Fan overcurrent cutout (The fan loads the electronic unit with more than 1A peak ). T..E1. July May K
18 BK irect urrent ompressor for Solar s (for stationary use only) Ra 1 V ata Sheet ode numbers BK without electronic unit 11Z11 Electronic unit 1V single: 11N, pcs: 11N1 LBP/MBP/(HBP) Evaporating temperature range to (1) Voltage range / max. voltage 1 V Fan output same as input voltage Max. machine compartment temperature omp. cooling at ambient temp. S or F 1 * * depending on application esign isplacement cm. Oil quantity cm 1 Maximum refrigerant charge g 1 Free gas vol. in compressor cm 87 Weight: ompressor/electronic unit kg./. Red stripe BK Barcode on white background Grey background Ra 17 N Z 11 MAE IN GERMANY S = Static cooling normally sufficient O = Oil cooling Yellow warning label F 1 = Fan cooling 1. m/s (compressor compartment temp. equal to ambient temp.) = Fan cooling. m/s necessary F Ra e E approval mark 81 type Variable speed Resistance, all windings ( ) Ω 1.8 Approvals (electronic unit) E 7/ 9/ imensions Height mm A 17 B 1 B1 18 B 7 Suction connector location/i.. mm. ±.9 Process connector location/i.. mm. ±.9 ø1 1 ø. 17 B1 B ø9 E B A ischarge connector location/i.. mm E..1/. ompressors on a pallet pcs July..A K..7. May
19 apacity (EN 19/EOMAF) apacity (ASHRAE) Power consumption urrent consumption (for V applications the following must be halved) A OP (EN 19/EOMAF) W/W OP (ASHRAE) W/W Test conditions EN 19/EOMAF ASHRAE ondensing temperature Ambient and suction gas temp. Liquid temperature Static cooling, 1V 1 Watt =.8 kcal/h preliminary data Accessories evices ompressor speed Electronic unit 11N with AEO Resistor (R1) Ω speed rpm AEO ontr.circ. current ma In AEO (Adaptive Energy Optimizing) speed mode the B compressor will always adapt its speed to the actual cooling demand. BK Standard automobile fuse Not IN 78 1A deliverable from anfoss Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap on in quantities Wire dimensions Size AWG ross section Gauge mm V operation ft. m ft. m *Length between battery and electronic unit V operation Fuse LE Thermostat Terminal plug Main switch R1 Solar panel Fan 8 F Operational errors shown by LE (optional) Number of flashes Error type Thermal cutout of electronic unit (If the refrigeration system has been too heavily loaded, or if the ambient temperature is high, the electronic unit will run too hot). Minimum motor speed error (If the refrigeration system is too heavily loaded, the motor cannot maintain minimum speed at approximately 1,8 rpm). start error (The rotor is blocked or the differential pressure in the refrigeration system is too high (> bar)). Fan overcurrent cutout (The fan loads the electronic unit with more than 1A peak ). T..A1. July May K
20 ata stamping The data stamping is placed on the top of the compressor, e.g. Z7 ( characters) 11A1F (7 characters) omposition of line 1 Z:ompressor type information (11Z = Z) 7: internal anfoss code omposition of line 11: Production week : Production year A: Production day A = Monday, B = Tuesday, = Wednesday, etc. 1: Production hour to or shift code 1,, F: anfoss ompressors internal production location code A to G: Germany / K to N: Slovenia / R, S: Mexico For the electronic unit, the code for date of manufacture is located on the printed circuit board, visible through the opening on the backside of the housing, where the cables get out. Mounting the electronic unit The cable plug of the electronic unit is mounted on the pins of the current leadin on the compressor. Then the electronic unit itself is mounted on the bracket of the compressor. At first the left side is mounted, then the right side is pressed over the screw on the bracket. The electronic unit snaps on to the bracket and is now securely mounted on the compressor. In case the electronic unit must be removed from the compressor, the screw has to be loosened. 819 onnectors 818 The compressor is equipped with ANON connectors which consist of a thickwalled, copperplated steel tube with high corrosion resistance, and a solderability equal to that of conventional copper connectors. ANON connectors are equipped with an aluminium cap (apsolut) which gives a tight sealing. The seal cap is easily removed with an ordinary pair of pliers or with a special tool. Mounting accessories Washer ompressor base Nut M Grommet sleeve 9 Mounting accessories for B compressors are supplied as a screw and nut assembly Each assembly is supplied in a bag containing four screws, nuts, washers, grommet sleeves and rubber grommets for mounting one compressor. The screw and nut assembly can be obtained in quantities under code no abinet base Screw M x Rubber grommet Filter drier selection Only filter driers which are declared by the manufacturer to be suitable for mobile applications must be used in refrigeration systems with BF, BF and B8F compressors. Filter material powder ending up in the compressor will lead to excessive wear of the piston and transmission parts, and metal particles deposited in the motor windings will cause the compressor to stop because the electric signal back to the electronic unit is disturbed. K..7. May
21 BF / Electronic Unit 11N1 BF / Electronic Unit 11N BF / Electronic Unit 11N BF Solar / Electronic Unit 11N BK Solar / Electronic Unit 11N B8F / Electronic Unit 11N8 May K..7. 1
22 ompressors ode no escription BF mm Standard 11Z Standard compressor, mm tube connectors, UL recognized BF mm Solar 11Z1 Standard compressor, mm tube connectors BF inch 11Z Same as 11Z, inch tube connectors, UL recognized BK (Ra) 11Z11 For stationary use only, mainly solar applications, mm tube connectors BF mm 11Z1 Standard compressor, mm tube connectors, UL recognized BF inch 11Z Same as 11Z1, inch tube connectors, UL recognized B8F mm 11Z8 Standard compressor, mm tube connectors Electronic Single Pack ode no escription Electronic standard 11N1 for BF/BF, speed setting, battery protection Electronic EMI 11N for BF/BF, radiation extra shielded, speed setting, battery protection Electronic extended EMI 11N9 for BF/BF, radiation extra shielded, conduction extra shielded, speed setting, battery protection Electronic AEO 11N for BF/BF, Adaptive Energy Optimization, speed setting, battery protection Electronic solar 11N for BF/BK, optimized for direct solar panel operation, speed setting Electronic BF high start 11N for BF only, extra high start performance, speed setting, battery protection Electronic B8F 11N8 for B8F only, Adaptive Energy Optimization, speed setting, battery protection Electronic Ipack ode no escription Electronic standard 11N11 for BF/BF, speed setting, battery protection, pcs. Electronic EMI 11N1 for BF/BF, radiation extra shielded, speed setting, battery protection, pcs. Electronic AEO 11N1 for BF/BF, Adaptive Energy Optimization, speed setting, battery protection, pcs. Electronic solar 11N1 for BF/BK, optimized for direct solar panel operation, speed setting, pcs. Electronic BF high start 11N1 for BF only, extra high start performance, speed setting, battery protection, pcs. Electronic B8F 11N81 for B8F only, Adaptive Energy Optimization, speed setting, battery protection, 8 pcs. ompressor sectional view Stator Shock absorber urrent leadin 817 Permanent magnet Shock absorber K..7. May
23 May K..7.
24 The anfoss product range for the refrigeration and air conditioning industry ompressors for refrigeration and air conditioning These products include hermetic reciprocating compressors, scroll compressors and fancooled condensing units. Typical applications are air conditioning units, water chillers and commercial refrigeration systems. Appliance controls For the regulation of refrigeration appliances and freezers anfoss supplies a product range of electromechanical thermostats produced according to customer specifications; electronic temperature controls comprising models with and without displays; service thermostats for servicing on all refrigerating and freezing appliances. ompressors and ondensing Units This part of the range includes hermetic compressors and fancooled condensing units for household refrigerators and freezers, and for commercial units such as bottle coolers and drinks dispensers. We also offer compressors for heat pumps, and 1 and V compressors for refrigerators and freezers in commercial vehicles and boats. Refrigeration and air conditioning controls Our full product range covers all control, safety, system protection and monitoring requirements in mechanically and electronically controlled refrigeration and air conditioning systems. The products are used in countless applications within the commercial and industrial refrigeration and air conditioning sectors. anfoss ompressors GmbH Mads lausen Str Flensburg / Germany anfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. anfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. anfoss and the anfoss logotype are trademarks of anfoss A/S. All rights reserved. K..7. / Produced by anfoss ompressor, EH9,.
ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL
148 OLD CONCORD TURNPIKE, BARRINGTON NH 03825 USA TEL (603) 868-5720 FAX (603) 868-1040 1-800-435-6708 E-Mail:sales@seafrost.com www.seafrost.com ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL
More informationNO-FROST CUSTOMER SUPPORT INFORMATION INFORMATION ON THE NO-FROST TECHNOLOGY WHITE GOODS
INFORMATION INFORMATION ON THE TECHNOLOGY The -Frost refrigerators are different from the other static refrigerators in terms of their operational system. In normal refrigerators, in the freezing section,the
More information543-0032-00, 943-0032-00. User s Manual
543-0032-00, 943-0032-00 User s Manual 1 Comfort Alert Diagnostics Faster Service And Improved Accuracy The Comfort Alert diagnostics module is a breakthrough innovation for troubleshooting heat pump and
More informationSERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS
SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER INDOOR UNIT AH-129 AH-MP14 OUTDOOR UNIT AU-129 AU-MP14 CONTENTS SPECIFICATIONS...2 EXTERNAL DIMENSIONS...4 WIRING DIAGRAMS...5 ELECTRICAL PARTS...6 MICROCOMPUTER
More informationINSTRUCTION MANUAL FOR RECREATIONAL REFRIGERATOR/FREEZER MODEL
INSTRUCTION MANUAL FOR RECREATIONAL REFRIGERATOR/FREEZER MODEL 15-LITER, 20-LITER, 35-LITER, 45-LITER, 60-LITER & 100-LITER SECTION 1 Basic Operation SECTION 2 Cleaning and Storing SECTION 3 Basic Trouble
More information3000W Power Inverter
3000W Power Inverter OWNER S MANUAL Model number-4573000 TO REDUCE THE RISK OF INJURY, USER MUST READ AND UNDERSTAND THIS INSTRUCTIONAL MANUAL. THIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDING THE
More informationService Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTM3-SF-1. Split System Cooling 4TTM3018-4TTM3060
4TTM3-SF-1 Service Facts Split System Cooling 4TTM3018-4TTM3060! CAUTION UNIT CONTAINS R-410A REFRIGERANT! R-410A OPERATING PRESSURE EXCEEDS THE LIMIT OF R-22. PROPER SERVICE EQUIPMENT IS REQUIRED. FAILURE
More informationMP-4000 Alarm List (Software version 2.4.3 or later)
Service Bulletin SUBJECT: MP4000 Alarm s BULLETIN: C 100 DATE: June 19, 2013 ALARM LIST Where it is possible the alarm number is kept the same as for MP-3000. MP-3000 holds alarm number from 0 to 127.
More informationSolenoid valves Type EVU
Data sheet Solenoid valves EVU EVU solenoid valves are designed to fit into compact refrigeration systems. Available in direct and pilot operated versions, they can be applied in liquid, suction, and hot
More informationLG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units
Multi Split Units If there is a fault on any LG Multi unit, an Error mark is indicated on the display window of the indoor unit, wired-remote controller, and LED s of outdoor unit control board. A two
More informationSERVICE MANUAL REFRIGERATION
SERVICE MANUAL REFRIGERATION ELECTROLUX ZANUSSI S.p.A. Publication no. Spares Operations Italy 599 35 61-04 Corso Lino Zanussi, 30 021218 I - 33080 PORCIA / PN (ITALY) ITZ/SERVICE/AA Fax +39 0434 394096
More informationECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
More informationVariable Capacity Compressors, a new dimension for refrigeration engineers to explore
Variable Capacity Compressors, a new dimension for refrigeration engineers to explore By: Marcos G. Schwarz, VCC Group Leader Corporate Research & Development, EMBRACO SA Abstract: This paper presents
More informationLG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems
Universal Split Systems If there is a fault on any LG Universal unit, a two digit number will appear on the remote controllers led display. If the unit does not have a remote controller the fault will
More information579(XX).(X)(X)(X)(X) Modularized Roof Top Air Conditioner
When ordering parts, always state: MODEL NO. - PRODUT NO. - QUANTITY - PART NUMBER - DESRIPTION For Electric Details also state: VOLTAGE - WATTAGE USA SERVIE OFFIE Dometic orporation 09 South Poplar Street
More informationPortable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
More informationSMD Rework Station TABLE OF CONTENTS
SMD Rework Station Thank you for purchasing the Hakko 50B SMD Rework Station. The Hakko 50B is designed to solder and desolder surface mounted devices with hot air. Please read this manual before operating
More informationAFE424 SERVICE PARTS
This is the parts list for the AFE. When looking up part numbers, always check the complete model and serial numbers to be certain of ordering the correct parts. The Air Cooled model has also been manufactured
More informationPortable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W
MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries
More informationRoof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS
Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS Ducted System RECORD THIS UNIT INFORMATION FOR FUTURE REFERENCE: Model Number: Serial Number: Date Purchased: This manual must be read and
More information12 Volt 30 Amp Digital Solar Charge Controller
12 Volt 30 Amp Digital Solar Charge Controller User s Manual WARNING Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions
More informationHEATER, AIR CONDITIONING AND VENTILATION
55-1 GROUP 55 HEATER, AIR CONDITIONING AND VENTILATION CONTENTS GENERAL DESCRIPTION 55-2 HEATER AND AIR CONDITIONING SYSTEM 55-4 HEATER CONTROL 55-6 A/C-ECU 55-7 A/C COMPRESSOR 55-9 CONDENSER 55-9 DUCT
More informationOPL BASIC. Dosing System for Professional Laundry machines. Contents
OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page
More informationMAC-120HE-01 Air-Cooled Chiller
MAC-120HE-01 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 208/230-1-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-01
More informationElectronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm
Electronic pressure measurement Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm WIKA data sheet PE 81.67 Applications Machine tools Hydraulics
More informationRecommended Compressor Installation Practices
ASPEN COMPRESSOR, LLC Phone: 508.481.5058 Fax: 508.480.0328 Email:info@aspencompressor.com Website: www.aspencompressor.com Recommended Compressor Installation Practices 1. COMPRESSOR SELECTION AND USE
More informationPlug-in relays Mini ISO relays
Powertrain Systems Chassis Systems Safety Security Body Driver Information Convenience Description Features Limiting continuous current 70 A Dimensional characteristics and the functional allocation of
More informationElectronic Pressure Switch EDS 300
Electronic Pressure Switch EDS 300 User manual Page 2 of 16 Content 1. Functions of the EDS 300...3 2. Mounting...3 3. Operating keys on the membrane keypad...4 4. Digital display...4 5. Output function...5
More informationtechnical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air
technical data RXS20-25-35E FBQ-B8V-B8V3B (single phase) Split Heat Pump Condensing Units air conditioning systems Split Sky Air Outdoor Units R-40A RXS-E2VB Split Sky Air Outdoor Units Features O u t
More informationThermostatic Sensor RAS-C² with RA-FN Radiator Valve (Fixed Capacity)
Data Sheet Thermostatic Sensor RAS-C² with RA-FN Radiator Valve (Fixed Capacity) Application RAS-C² thermostatic sensor RA-FN angle valve The RAS-C² thermostatic sensor is a selfactuating proportional
More informationCRN32-2-2 A-F-G-E-HQQE 3x400D 50 HZ
GRUNDFOS DATA BOOKLET CRN32-2-2 A-F-G-E-HQQE 3x4D 5 HZ Grundfos Pump 96122352 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn32/96122352/crn-32-2-2-a-f-g-e-hqqe.html
More informationService manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.
Website: www.andico.com.au Service manual CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. - ONLY FOR AUTHORISED SERVICE PERSONNEL. MODELS: MPK1-09CR-QB8 MPK1-12ER-QB6
More informationCharge Regulator SCR 12 Marine
Charge Regulator SCR 12 Marine Manual Many thanks for purchasing a superwind product. The SCR 12 Marine is a charge regulator of highest quality and will perfectly and reliably charge your batteries for
More informationPortable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support
More informationSECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT
SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION A. The Work specified in this Section consists of designing, furnishing and installing factory-assembled
More informationKit 106. 50 Watt Audio Amplifier
Kit 106 50 Watt Audio Amplifier T his kit is based on an amazing IC amplifier module from ST Electronics, the TDA7294 It is intended for use as a high quality audio class AB amplifier in hi-fi applications
More informationTrouble Shooting BD & TW Compressor Systems 12 and 24 Volt
Trouble Shooting BD & TW Compressor Systems 12 and 24 Volt Determine the Model. The data plate is on the left end near the wiring entrance. BD - BD air* TW - Tradewinds air** BDAW - BD air/water TWAW -
More informationVolkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)
17 Engine-Lubrication system (Page GR-17) Lubrication system components, removing and installing Oil pan, removing and installing Oil pressure and oil pressure switch, checking Dynamic oil pressure warning
More informationPortable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW
Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer
More informationhore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &
hore nd Offsh arine an ms for Ma geration System & Refrig HV VAC & PRODUCT CATALOGUE AUTONOMOUS AIR CONDITIONERS O ! "# $ % & " ' (! ) * +,+( -../01..2 PRODUCT CATALOGUE 72-17 AUTONOMOUS AIR CONDITIONERS
More informationT7560A,B,C Digital Wall Module
T7560A,B,C Digital Wall Module HONEYWELL EXCEL 5000 OPEN SYSTEM BEFORE INSTALLATION All wiring must comply with local electrical codes and ordinances or as specified on installation wiring diagrams. Digital
More informationCW-5000/ 5200,1'8675,$/ &+,//(5 86(5 0$18$/
CW-5000/ 5200 Contents Cautions ---------------------------------------------------------------- 3 Parts introduction --------------------------------------------------- 4 Installation ------------------------------------------------------------
More informationTable V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.
Table V Troubleshooting Checklist for Refrigeration Systems TROUBLE POSSIBLE CAUSE CORRECTIVE MEASURE High condensing pressure. Low condensing pressure. Air or non-condensable gas in system. Inlet water
More informationREFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:
7610.478.16 8/99 INSTRUCTION MANUAL Models 8005, 8010, 8015 For Sales & Service please contact: CENTRAIR Air Systems & Supplies Phone: 705-722-5747 Fax: 705-722-5458 Email: sales@centrair.ca Website: www.centrair.ca
More informationCooling system components, removing and installing
Page 1 of 34 19-1 Cooling system components, removing and installing WARNING! The cooling system is pressurized when the engine is warm. When opening the expansion tank, wear gloves and other appropriate
More informationAIR-CONDITIONER SPLIT TYPE
FILE NO. A08-016 SERVICE MANUAL AIR-CONDITIONER SPLIT TYPE RAS-M10PKVP-E, RAS-M13PKVP-E, RAS-M16PKVP-E, RAS-M18PKVP-E / RAS-M10PKVP-ND, RAS-M13PKVP-ND, RAS-M16PKVP-ND, RAS-M18PKVP-ND / RAS-3M26GAV-E1,
More informationUSER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting
More informationINSTALLATION & SERVICE MANUAL. Display Panel
INSTALLATION & SERVICE MANUAL Display Panel The PowerLine EMS TM is a specialized power distribution and energy management system intended to be used in recreational vehicles. The Control Module is housed
More informationMCR1900 Media Converter 19-Slot Chassis
MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the
More informationCooling system components, removing and installing
Engine BHW Cooling system components, removing and installing Page 1 / 24 19-1 Cooling system components, removing and installing Warning! When doing any repair work, especially in the engine compartment,
More informationE2 Series Electric Furnaces
E2 Series Electric Furnaces Service Manual Table of Contents Electrical Requirements... 10 Codes, Specifications Requirements... 10 Connection Supply Service Wires... 10 Furnace Sequence of Operation...
More informationMeasurement And Application of Performance Characteristics Of A Free Piston Stirling Cooler
Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 00 Measurement And Application of Performance Characteristics Of A Free Piston
More informationA/C refrigerant system, overview
Page 1 of 19 87-18 A/C refrigerant system, overview A/C refrigerant system, identification Typical A/C refrigerant system with expansion valve and receiver drier 1 - Evaporator 2 - Expansion valve 3 -
More informationPortable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CHCSCS Voltage rating: 120V~60Hz Power rating : 1400W(Cooling) Power rating : 1350W(Heating) Customer Support : 1-800-474-21477
More informationInstallation & User Manual Radio Remote rev1.0.3
EN Installation & User Manual Radio Remote rev1.0.3 RC-20E RC-21E RC-22E RC-23E SLEIPNER MOTOR AS P.O. Box 519 N-1612 Fredrikstad Norway Tel: +47 69 30 00 60 Fax: +47 69 30 00 70 www.side-power.com sidepower@sleipner.no
More informationVLT Series 300 Watt True Sine Wave Inverter
VLT Series 300 Watt True Sine Wave Inverter PURE SINE WAVE INVERTER I ON 0 OFF REMOTE CONTROL AC OUTPUT POWER STATUS Vout Vin Models VLT12-300 VLT24-300 300 Watt VLT Series Inverter - 1 - TABLE OF CONTENTS
More information14. Troubleshooting Guide
14. Guide 14.1 Refrigeration Cycle System In order to diagnose malfunctions, ensure the air conditioner is free from electrical problems before inspecting the refrigeration cycle. Such problems include
More information12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations
12S, 14S, 15S Series Time Delay Relays and Sequencers Time Delay Relays and Sequencers The Therm-O-Disc type 12S, 14S and 15S series time delay relays and sequencers are field-proven devices for controlling
More informationDrayton Digistat +2RF/+3RF
/+3RF Programmable Room Thermostat Wireless Model: RF700/22090 Model: RF701/22092 Power Supply: Battery - Thermostat Mains - Digistat SCR Invensys Controls Europe Customer Service Tel: 0845 130 5522 Customer
More informationTechnical Information
Date of last update: Jul-05 Ref: Application Engineering Europe OIL PRESSURE SAFETY CONTROL FOR SEMI-HERMETICS 1 Oil Pressure Differential Switches The oil pressure differential switch breaks the control
More informationspecializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST 1967-72 CHEVROLET PICKUP
specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST 1967-72 CHEVROLET PICKUP CONTROL & OPERATING INSTRUCTIONS The controls on your new Perfect
More informationR22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power
R22. K Control. Indoor Unit. Nomenclature. PL H 3 G K H B Compatibility Unit style Heat Pump Horse Power Control Boost Heaters R22. K Control. Outdoor Unit. Nomenclature. PU H 3 Y K A Compatibility Outdoor
More informationLOBOY 16 AIR CONDITIONERS
INSTRUCTION MANUAL FOR: LOBOY 16 AIR CONDITIONERS McLean Midwest Corp. dba: McLean Cooling Technology 11611 Business Park Blvd. N Champlin, MN 55316 Tel: 763-323-8200 Fax: 763-576-3200 www.mcleancoolingtech.com
More informationBrake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!
Documentation Brake module AX5021 Please read this document carefully before installing and commissioning the brake module! Version : 1.2 : 2012.03.05 Date Article-no. : TDmlAX-5021-0000-0200 Page 2/8
More informationFTXS. Wall Mount Heat Pump or Cooling Only
FTXS Wall Mount Heat Pump or Cooling Only EXPERTISE AND INNOVATION Daikin s FTXS SkyAir systems feature streamlined, wall mounted indoor units paired with quietly compact outdoor units. Available in both
More informationSplit units TH with hermetic compressors
Split units TH with compressors Refrigeration units in split variant. Available with screw or solder terminal. Condensing unit with sound insulated weatherproof housing for outdoor installation. Split
More informationWWZ High efficiency HYBRID heat pumps with E.V.I compressor in two sections
High efficiency HYRID heat pumps with E.V.I compressor in two sections infolinia: +48 691 262 691-20 +43 +65 E.V.I..O.P. 4,1 The series of high efficiency hybrid heat pumps has been specifically designed
More informationTECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 79G SA 99G FILE NO. SA 79G SA 99G REFERENCE NO. SM700402
TECHNICAL & SERVICE MANUAL SA 79G SA 99G FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. Destination SA-79G-A 1 851 005 18 General (50Hz) & Europe SA-99G-A 1 851 005 19 SA 79G SA 99G REFERENCE
More informationRoHS. Shock / vibration resistant. Magnetic field proof. Many variants
Sendix 5000 / 500 (Shaft / Hollow shaft) Push-Pull / RS4 ue to their sturdy bearing construction in Safety-ock esign, the Sendix 5000 and 500 offer high resistance against vibration and installation errors.
More informationDuct Humidity Transmitter
SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers
More informationModel: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0
Air Conditioner Service Manual 2 3 Model: AC-S13CG x 2 3 Content Technical specification.. 4 Performance curve.5 Outline & dimension of indoor unit..10 Outline & dimension of outdoor unit 11 Exploded view
More informationSERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS
SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS TABLE OF CONTENTS 1. Warnings...2 2. Accessibility Of Appliance...3 3. Unit Dimensions And Specifications...3 4. Unit Specifications
More informationRAY-MAX Integrated Solar Power Strip
RAY-MAX Integrated Solar Power Strip 600008, 600009, 600010, 600208, 600209, 600210 Owner s Manual NEXTRONEX, INC. Revision Date: 10/27/14 Contents 1. Safety Instructions... 3 2. General Equipment Warnings...
More informationABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01
ABB Drives User s Manual Pulse Encoder Interface Module RTAC-0 Pulse Encoder Interface Module RTAC-0 User s Manual 3AFE 64486853 REV A EN EFFECTIVE:.5.00 00 ABB Oy. All Rights Reserved. Safety instructions
More informationMounting instruction Read instructions carefully!
Europasolar GmbH Uses sun energy and environmental awareness intelligence Solar Charger LR 122430 Mounting instruction Read instructions carefully! Cordial congratulation on the acquisition of this loading
More informationCold Room & Refrigeration System (Casserole Assembly) No of units: 1
Technical Specifications Cold Room & Refrigeration System (Casserole Assembly) No of units: 1 For chiller storage of all sorts of items Chiller storage temperature: 2-5 C Provides excellent thermal efficiency
More informationMobile Data Power Model: MDP-25
Mobile Data Power Model: MDP-25 Topic Section Features... 2 Operational Features Summary... 2 Back-up Battery Power Internal Charger Voltage Spike Protection RF Noise Filtering Warning of Imminent Loss
More informationSERVICE MANUAL FOR 12 VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOF TOP UNITS ONLY
RV Products Division SERVICE MANUAL FOR 12 VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOF TOP UNITS ONLY Airxcel, Inc. RV Products Division P.O. Box 4020 Wichita, KS 67204 1976A376 (1-11) TABLE OF CONTENTS
More informationSIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:
OPERATING LIMITS Flows up to: m /h* Heads up to: m C Max operating pressure: bars Temperature range: - à + C Max ambient temperature: + C ND of orifices: à * m /h: parallel operation SIRIUX SINGLE AND
More informationIntegrated Presetting Valves for Normal 013G0372 and Small 013G0373 Volume Flows
Integrated Presetting Valves for Normal 013G0372 and Small 013G0373 Volume Flows Application Integrated valves, type RA-N (013G0372) and RA- U (013G0373), with built-in presetting are designed for incorporation
More informationMarine Refrigerator/freezer CR 195 & CR 195 Stainless Steel-INOX
Marine Refrigerator/freezer CR 195 & CR 195 Stainless Steel-INOX Installation and operating instructions Indel Marine USA, Inc. 3400 Gateway Drive Unit 107 Pompano Beach, FL 33069 Tel +1 954 984 8448,
More informationIntegrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows RA-U
Integrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows Application Integrated valves, type RA-N (013G1382) and RA- U (013G1383), with built-in presetting are designed for
More informationARMSTRONG AIR HEAT PUMPS www.armstrongair.com
INDEX ELECTRIC FURNACE MODULAR AIR SYSTEM EFC/EFV... 5-10 electric Heat Kits... 5-11 evaporator coils EC1P / EM1P UPFLOW / COUNTERFLOW APPLICATIONS and upflow / horizontal applications (CASED)... 5-6 5-7
More informationTable Z. Troubleshooting Chart for Air Conditioners. Cause
Troubleshooting Chart for Air Conditioners Type of Unit Complaint Cause With open-type compressor Electric motor will not start Power failure Check circuit for power source Compressor stuck Locate cause
More information33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
More informationAir conditioning service unit CAAS500
Air conditioning service unit CAAS500 OPERATING INSTRUCTIONS TES1453 09/2004 C A A S 5 0 0 O P E R A T I N G I N S T R U C T I O N S P a g e 2 IMPORTANT THIS MANUAL CONTAINS INFORMATION PERTINENT TO OPERATOR
More informationThe Ultimate Truck Stock Motor
The Ultimate Truck Stock Motor What is a Rescue Motor? Universal Replacement Motor for Condenser Fan and Direct Drive Blower Applications Multi-Horsepower PSC Motors Flexible Mounting Options Permanent
More informationUHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual
UHIR Series Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater Owner s Manual This manual covers installation, maintenance and repair parts. Read carefully before attempting to
More informationMODEL 2202IQ (1991-MSRP $549.00)
F O R T H E L O V E O F M U S I C F O R T H E L O V E O F M U S I C MODEL 2202IQ (1991-MSRP $549.00) OWNER'S MANUAL AND INSTALLATION GUIDE INTRODUCTION Congratulations on your decision to purchase a LINEAR
More informationWhy and How we Use Capacity Control
Why and How we Use Capacity Control On refrigeration and air conditioning applications where the load may vary over a wide range, due to lighting, occupancy, product loading, ambient weather variations,
More information12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual
12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual This 30Amp charge controller is designed to protect your 12Volt Lead-acid or Gel-cell battery from being overcharge by solar
More informationRDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems
3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost
More informationVolkswagen B3 Passat General-Engine 4 CYL. 19 Engine - Cooling System (Page GR-19)
19 Engine - Cooling System (Page GR-19) Cooling system draining and filling general information Body components, layout Engine components, layout Radiator fan run-on checking Recommended mixture ratios
More informationDual Pressure Controls for Refrigeration, Air-conditioning and Heatpump Applications
Series P78 ual Pressure Controls for Refrigeration, Air-conditioning and Heatpump Applications Product Bulletin These dual pressure controls are designed for use in a variety of applications involving
More informationApplied Electronics. Commercial Dimming System UPDATE NOTICE
REV. A Applied Electronics Commercial Dimming System UPDATE NOTICE This notice is to inform the end user of an additional feature added to this DP12/2400 dimming unit. This unit has been outfitted with
More informationETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL
RANCO INSTALLATION INSTRUCTIONS ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL Relay Electrical Ratings PRODUCT DESCRIPTION The Ranco ETC is a microprocessor-based family of electronic temperature controls,
More informationT15 AIR CONDITIONER INSTRUCTION MANUAL FOR: McLean Thermal 11611 Business Park Blvd. N Champlin, MN 55316 Tel: 763-323-8200 Fax: 763-576-3200
INSTRUCTION MANUAL FOR: T15 AIR CONDITIONER McLean Thermal 11611 Business Park Blvd. N Champlin, MN 55316 Tel: 763-323-8200 Fax: 763-576-3200 www.mcleanthermal.com INSTRUCTION MANUAL TABLE OF CONTENTS
More informationHeating, air-conditioning, cooling
Series description Design High efficiency, single stage, low pressure, inline centrifugal pump Supplied with EC motor and electronic duty adaptation Available in glanded construction, mechanical shaft
More informationSECTION 15732 AIR CONDITIONING UNIT
SECTION 15732 AIR CONDITIONING UNIT PART 1 GENERAL 1.01 SUMMARY A. Section includes: 1. Packaged, split system air conditioning unit No. 1. 1.02 REFERENCES A. Air-Conditioning, Heating, and Refrigeration
More informationSeries IDU/IDF. Refrigerated Air Dryer
Refrigerated ir ryer Series IU/IF The models IF1 to 11 and IU3 to 6 have been revised. For details, refer to catalog no. S30-8. Similar updating for other IF/IU models is scheduled to follow shortly. In
More information