OPTO-TOUCH LTB Series
|
|
|
- Shon Cooper
- 9 years ago
- Views:
Transcription
1 OPTO-TOUCH LTB Series Banner LTB Series Optical Touch Buttons are touch-activated photoelectric switches designed to replace capacitive touch switches and mechanical push buttons. The OPTO-TOUCH's SPDT electromechanical relay output changes state, alternating between "on" and "off", whenever a finger, introduced into the "touch area" (yoke) of the switch, interrupts the LTB's infrared sensing beam. Banner LTBs are ergonomically designed to eliminate the hand, wrist, and arm stresses associated with mechanical push buttons. They require absolutely no physical pressure to operate. LED indicators light for "power on" and "output activated". LTBs are highly resistant to EMI, RFI, and ambient light interference, and are constructed from black polysulfone (or red Lexan ) and VALOX for reliability in industrial environments. The 30-mm threaded base provides easy mounting, and LTBs are easily retrofitted to existing machines. See the listings on pages 2 and 3 for available models. Specifications Alternate Action Optical Touch Buttons Supply Voltage: 105 to 130V ac or 210 to 250V ac, depending upon model. See listings of available models, pages 2 and 3. Output Configuration: All models have SPDT electromechanical relay (one N.O. contact, one N.C. contact). Output Rating: Maximum voltage is 250V ac or 30V dc. Maximum current 7 amps (resistive load), 1 HP max. Minimum load.05 watts (dc),.05va (ac). Mechanical life of relay 50,000,000 operations (min.). Electrical life of relay 100,000 operations (min.) at full resistive load. Transient suppression is recommended when switching inductive loads. Ambient Light Immunity: 120,000 lux (direct sunlight). EMI/RFI Immunity: The OPTO-TOUCH is highly resistant to both single and mixed EMI and RFI noise sources. Operating Temperature Range: -20 to +50 C (-4 to +122 F). Indicator LEDs: Two indicator LEDs. One lights when power is "on"; the other lights when the infrared sensing beam is interrupted. Construction: Black polysulfone or red Lexan upper housing and fiber-reinforced VALOX base. Electronics fully epoxy-encapsulated. Totally sealed, non-metallic enclosure. The LTB's threaded base has M30 x 1,5 external threads and 1/2" NPSM internal threads. The base requires a 1-3/16" diameter mounting hole (fits most standard automotive-size "jumbo" legend plates and oiltight pushbutton holes). OPTO-TOUCH LTBs are rated NEMA 1, 3, 4, 4X, 12, and 13. LTB Series Alternate Action Optical Touch Button (QD model shown) E71083 LR Cable: Quick-disconnect (QD) models require model MBCC conductor mini-type cable (p/n 25496), purchased separately. QD cables are 12 feet long. Models with attached cable (non-qd models) are supplied with 6 feet of PVC-jacketed, 22 AWG 5-conductor cable. Environmental Considerations (models with polysulfone housing): Prolonged exposure of the OPTO-TOUCH to direct outdoor sunlight will cause embrittlement of the polysulfone housing. Window glass effectively filters longer wavelength ultraviolet and provides excellent protection from sunlight. Contact the factory Application Engineering Department regarding outdoor applications. Clean periodically using a mild soap solution and a soft cloth. Avoid the following substances, as they will attack polysulfone to varying degrees: esters, ketones, aromatic hydrocarbons, chlorinated hydrocarbons, and strong alkaline materials. Environmental Considerations (models with Lexan housing): Prolonged exposure of the OPTO-TOUCH to hot water and moist high-temperature environments above 150 F (66 C) should be avoided. Aromatic hydrocarbons (such as xylene and toluene), halogenated hydrocarbons, and strong alkalis should be avoided. Clean periodically using mild soap solution and a soft cloth. Read all WARNINGs carefully. WARNING. Banner OPTO-TOUCH LTB Series Optical Touch Buttons are intended as generalpurpose initiators, and are not safety devices. Like most solid-state devices, they are as equally likely to fail in the conducting ("on") state as in the non-conducting ("off") state. If OPTO-TOUCH Optical Touch Buttons are used to initiate machines or operations in which false operation of an Optical Touch Button could be dangerous, pointof-operation guarding devices or related safety controls must be installed and maintained to meet all appropriate OSHA regulations and ANSI B11 machine safety standards. NOTE: In addition to the standards and regulations mentioned above, there are numerous regulations and machine safety standards that apply to specific industries. For assistance in obtaining copies of any of these standards, contact Banner at the address and or numbers listed at the bottom of page 4.
2 LTB Series Alternate Action OPTO-TOUCH Model Listing and Hookup Information (all models have SPDT electromechanical relay output) Models* LTBA5(L) LTBA5(L)QD LTBB5(L) LTBB5(L)QD Operating voltage, cabling 120V ac, 6-foot attached cable 120V ac, 5-pin quick-disconnect base 240V ac, 6-foot attached cable 240V ac, 5-pin quick-disconnect base Quick Disconnect (QD) Option (order model MBCC-512 mini-type cable, 12-foot length, p/n 25496) Cable connector, end view Cable connector, side view (MBCC-512 cable): (MBCC-512 cable): 105 to 130V ac (LTBA5 models) 210 to 250V ac (LTBB5 models) LTB base, quick-disconnect models, side and end views: *"L" in model suffix indicates Lexan upper housing. See listing, page 3. OPTO-TOUCH LTB Mounting Hole Information The OPTO-TOUCH has a 30 millimeter threaded base which fits directly into a standard mounting hole for an oiltight push button. A lock ring, supplied with each OPTO-TOUCH, may be used to prevent switch rotation. The mounting hole details shown at the right are used for the OPTO- TOUCH and also for standard oiltight push buttons and their legend plates. The drawing at the far right shows how to approximate the keyway using a drill hole. Model SMB30S Swivel Mount Bracket The model SMB30S swivel-mount bracket (p/n 33204) is a versatile means for mounting a Banner OPTO-TOUCH Optical Touch Button. The SMB30S lets you ergonomically position the OPTO-TOUCH on most machinery for maximum operator comfort and convenience. The SMB30S mounts by its base. Its swivel ball locks snugly in place when its two clamping bolts are tightened. Bracket material is black VALOX. Hardware is stainless steel, and mounting bolts are included. The photo at the right shows a model SMB30S bracket with an OPTO-TOUCH attached. SMB30S WARNING Never use an OPTO-TOUCH Optical Touch Button as an actuator in an emergency stop (E-Stop) circuit. E-Stop actuators must be purely mechanical devices that require no power to operate. OPTO-TOUCH Optical Touch Buttons require power to operate and must not be used as E-Stop actuators under any circumstances.
3 LTB Series Alternate Action OPTO-TOUCH Dimensions OPTO-TOUCH Field s OPTO-TOUCH Field s (see drawing, below) are designed to prevent inadvertent activation of OPTO-TOUCHs due to objects (loose clothing, debris, etc.) which might accidentally block the sensing beam. Field covers are constructed of rugged polycarbonate-pet polyester blend, which is capable of absorbing high impacts, even at low temperatures. This material is highly resistant to abrasion and to damage by most chemicals. Every OPTO-TOUCH is supplied with a black field cover, as standard. Field covers are available separately in four colors, which can be used to differentiate touch button functions when several touch buttons are in use: Black OTC-1-BK, p/n Yellow OTC-1-YW, p/n Red OTC-1-RD, p/n Green OTC-1-GN, p/n Model shown has built-in, attached cable. See page 2 for QD-style base. Lexan and VALOX are registered trademarks of General Electric Company. Safety Instruction A field cover has been supplied with this OTB. It should be installed, as shown in the drawing above, to minimize the possibility of unintended switch operation. If this cover is missing or has become lost or damaged, contact Banner immediately at (612) for a no-charge replacement. Ordering Information: OPTO-TOUCH Optical Touch Buttons are shipped with a black field cover, as standard. A black field cover will be received if the OPTO-TOUCH is ordered by its model number (only). Red, yellow, or green field cover may be specified instead by ordering the OPTO-TOUCH using the appropriate 5-digit part number from the table, below. Field covers may also be ordered separately (above). 120V ac 220/240V ac Attached 6-foot cable Quick disconnect Model Lexan upper housing Polysulfone upper housing LTBA5 LTBA5QD LTBA5L LTBA5LQD LTBB5 LTBB5QD LTBB5L LTBB5LQD OPTO-TOUCH Optical Touch Buttons Part Numbers - Alternate Action Models Black Red Yellow Green NOTE: Banner Optical Touch Buttons are manufactured and sold under license for U. S Patent #4,939,358. 3
4 OPTO-TOUCH OTB Series Momentary Action Optical Touch Buttons Banner Optical Touch Buttons are touch-activated photoelectric switches designed to replace capacitive touch switches and mechanical push buttons. The OPTO-TOUCH's SPDT electromechanical relay or solid-state output (depending upon model) is activated for as long as a finger, introduced into the "touch area" (yoke) of the switch, interrupts the OPTO-TOUCH's infrared sensing beam. Banner Optical Touch Buttons are ergonomically designed to eliminate the hand, wrist, and arm stresses associated with mechanical push buttons. They require absolutely no physical pressure to operate. LED indicators light for "power on" and "output activated". All models are highly resistant to EMI, RFI, and ambient light interference. OTBs have either a black polysulfone (or red Lexan ) upper housing and VALOX base. Lexan models have the letter "L" in their model number suffix. Environmental considerations for use of the two types differ; see specifications below. The 30- mm threaded base on all models provides easy mounting, and Banner Optical Touch Buttons are easily retrofitted to existing machines. See pages 2 and 5 for model listings. Specifications Supply Voltage: Models for 105 to 130V ac, 210 to 250V ac (50/60 Hz), 10 to 30V dc, or 20 to 30V ac/dc (at 25 ma, exclusive of load). Output Configuration: AC and ac/dc models: All models have SPDT electromechanical relay (one N.O. contact, one N.C. contact). DC-only models: OTBVN6 models have complementary NPN sinking outputs; OTBVP6 models have complementary PNP sourcing outputs. Output Rating: AC and ac/dc models: Maximum voltage is 250V ac or 30V dc. Maximum current is 7 amps (resistive load), 1 HP max. Minimum load is.05 watts (dc),.05va (ac). Mechanical life of relay is 50,000,000 operations (minimum). Electrical life of relay is 100,000 operations (min.) at full resistive load. Transient suppression recommended when switching inductive loads. DC models: 150 ma maximum load (each output). Ambient Light Immunity: 120,000 lux (direct sunlight). EMI/RFI Immunity: The OPTO-TOUCH is highly resistant to both single and mixed EMI and RFI noise sources. Operating Temperature Range: -20 to +50 C (-4 to +122 F). Indicator LEDs: Two indicator LEDs. One lights whenever power is "on"; the other lights whenever the output relay is activated. Construction: Black polysulfone (or red Lexan ) upper housing and fiber-reinforced VALOX base. Electronics fully epoxy-encapsulated. Totally sealed, non-metallic enclosure. Threaded base has OTB Series Momentary Action Optical Touch Button (QD model shown) E71083 LR M30 x 1,5 external threads and 1/2" NPSM internal threads. Base requires a 1-3/16" diameter mounting hole (fits most standard automotive-size "jumbo" legend plates and oiltight pushbutton holes). Supplied with a field cover of polycarbonate-pet polyester. OPTO- TOUCH OTBs are rated NEMA 1, 3, 4, 4X, 12, and 13. Cable: DC-only Quick-disconnect (QD) models require model MBCC conductor mini-type cable (p/n 25226); AC and ac/dc Quickdisconnect (QD) models require MBCC conductor cable (p/n 25496; cables are purchased separately). Mini-type QD cables are 12 feet long. Models with attached cable (non-qd models) are supplied with 6 feet of PVC-jacketed, 22 AWG 4- or 5-conductor cable. Environmental Considerations (models with polysulfone housing): Prolonged exposure of the OPTO-TOUCH to direct outdoor sunlight will cause embrittlement of the polysulfone housing. Window glass effectively filters longer wavelength ultraviolet and provides excellent protection from sunlight. Contact the factory Application Engineering Department regarding outdoor applications. Environmental Considerations (models with Lexan housing): Prolonged exposure of the OPTO-TOUCH to hot water and moist high-temperature environments above 150 F (66 C) should be avoided. Aromatic hydrocarbons (such as xylene and toluene), halogenated hydrocarbons, and strong alkalis should be avoided. Clean periodically using mild soap solution and a soft cloth. Avoid strong alkaline materials. Read all WARNINGs carefully. WARNING. Banner OPTO-TOUCH OTB and OTBL Series Optical Touch Buttons are intended as general-purpose initiators, and are not safety devices. Like most solid-state devices, they are as equally likely to fail in the conducting ("on") state as in the non-conducting ("off") state. If OPTO-TOUCH Optical Touch Buttons are used to initiate machines or operations in which false operation of an Optical Touch Button could be dangerous, point-of-operation guarding devices or related safety controls must be installed and maintained to meet all appropriate OSHA regulations and ANSI B11 machine safety standards.
5 OTB Series Momentary Action OPTO-TOUCH Hookup Information and Model Listing 10-30V DC models (see page 5 for ordering information) Add "L" to specify Lexan upper housing (others are polysulfone); "QD" in model suffix indicates Quick Disconnect base. OTBVN6(L) and OTBVN6(L)QD complementary (+) (-) sinking outputs Model OTBVN6(L)QD requires MBCC-412 cable (p/n 25226, purchase separately). OTBVP6(L) and OTBVP6(L)QD complementary sourcing outputs (+) (-) Model OTBVP6(L)QD requires MBCC-412 cable (p/n 25226, purchase separately). Hookup Information and Model Listing AC and AC/DC models (see page 5 for ordering information) Add "L" to specify Lexan upper housing (others are polysulfone); "QD" in model suffix indicates Quick Disconnect base. Models OTBA5(L) OTBA5(L)QD OTBB5(L) OTBB5(L)QD OTBVR81(L) 120V ac, SPDT electromechanical relay output, 6-foot attached cable 120V ac, SPDT electromechanical relay output, QD base (use MBCC-512 cable) 220/240V ac, SPDT electromechanical relay output, 6-foot attached cable 220/240V ac, SPDT electromechanical relay output, QD base (use MBCC-512 cable) 20-30V ac or dc*, SPDT electromechanical relay output, 6-foot attached cable) OTBVR81(L)QD 20-30V ac or dc*, SPDT electromechanical relay output, QD base (use MBCC-512 cable) QD models require model MBCC-512 cable (p/n 25496, purchase separately). OTBA5 models: 105 to 130Vac OTBB5 models: 210 to 250V ac OTBVR81 models: 20 to 30V ac or dc* *20-30V dc power may be applied without regard to polarity Quick Disconnect (QD) Option (order model MBCC-412 or MBCC-512 mini-type cable) SJT-type cable, 12 foot lengths Cable connector end view, MBCC-412 Cable connector end view, MBCC-512 Cable connector, side view cable (p/n 25226), for dc-only models cable (p/n 25496), for ac and ac/dc models (MBCC-412 and MBCC-512 cable) The model SMB30S swivel-mount bracket (p/n 33204) is a versatile means for mounting a Banner OPTO-TOUCH Optical Touch Button. The SMB30S lets you ergonomically position the OPTO-TOUCH on most machinery for maximum operator comfort and convenience. The SMB30S mounts by its base. Its swivel ball locks snugly in place when its two clamping bolts are tightened. Bracket material is black VALOX. Hardware is stainless steel, and mounting bolts are included. The photo shows a model SMB30S bracket with an OPTO-TOUCH attached.
6 OTB Series Momentary Action OPTO-TOUCH OPTO-TOUCH base 4-pin QD base (dc models) OPTO-TOUCH base 5-pin QD base (ac and ac/dc models) Dimensions (see also QD base, shown above) VALOX and Lexan are registered trademarks of General Electric Company. OPTO-TOUCH Field s OPTO-TOUCH Field s (see drawing, below) are designed to prevent inadvertent activation of OPTO-TOUCHs due to objects (loose clothing, debris, etc.) which might accidentally block their sensing beam. Field covers are constructed of rugged polycarbonate-pet polyester blend, which is capable of absorbing high impacts (even at low temperatures). This material is highly resistant to abrasion and to damage by most chemicals. Every OPTO-TOUCH is supplied with a black field cover, as standard. Field covers are available separately in four colors, which can be used to differentiate touch button functions when several touch buttons are in use: Black model OTC-1-BK, p/n Red model OTC-1-RD, p/n Yellow model OTC-1-YW, p/n Green model OTC-1-GN, p/n Safety Instruction A field cover has been supplied with this OPTO-TOUCH. It should be installed, as shown in the drawing at the right, to minimize the possibility of unintended switch operation. If this cover is missing or has become lost or damaged, contact Banner immediately at (612) for a no-charge replacement. 3
7 Important Application Information Use of OPTO-TOUCH Optical Touch Buttons for Two-hand Machine Trip Controls Requirements for Anti-tiedown Circuitry Two-hand trip control has been a popular means for actuation of single-stroke presses and other single-cycle machinery for many years. Optical touch buttons (OTBs) provide an ergonomic (stress-free) alternative to conventional mechanical push buttons used as actuators in two-hand trip controls. OSHA Requirement for Anti-tiedown Control Use of OTBs for two-hand trip machine actuation must include "anti-tiedown" control to prevent any means of defeating one or both actuators to create a one-hand trip. Federal law mandates the use of anti-tiedown control when two-hand trip actuators are used for cycle initiation of a single stroke part revolution clutched mechanical power press. OSHA Code of Federal Regulation, Edition, CFR Title 29, Part (b) (6) (i) states: "A two-hand trip shall have the individual operator s hand controls protected against unintentional operation and have the individual operator s hand controls arranged by design and construction and/or separation to require the use of both hands to trip the press and use a control arrangement requiring concurrent operation of the individual operator s hand controls." Concurrent or "synchronous" actuation of two-hand trips is the most popular approach to anti-tiedown control. European Standard pren 574, titled "Safety of Machinery - Two-handed Control Device", defines synchronous actuation as follows: "6.7 Synchronous actuations In synchronous actuation an output signal shall be generated only when both control actuating devices are actuated - in a time which is less than or equal to 0.5 seconds If the control actuating devices are not actuated synchronously the output signal shall be prevented and it shall be necessary to release both control actuating devices and to reinitiate both input signals." WARNING In the United States, the functions that a two-hand control device is intended to perform are regulated by the Occupational Safety and Health Administration (OSHA). Whether or not any particular two-hand control system installation meets all applicable OSHA requirements depends upon the details of how the two-hand control device is applied, installed, operated, and maintained. When properly installed, a two-hand control device using OPTO-TOUCH OTB Series Optical Touch Buttons can provide protection only for the hands of the machine operator, and is not a point of operation personnel guarding device, as defined by OSHA regulations. It is necessary to install point of operation guarding devices, such as safety light curtains and/or hard guards, to protect personnel from dangerous machine motion. WARNING Never use an OPTO-TOUCH Optical Touch Button as an actuator in an emergency stop (E-Stop) circuit. E-Stop actuators must be purely mechanical devices that require no power to operate. OPTO- TOUCH Optical Touch Buttons require power to operate and must not be used as E-Stop actuators under any circumstances. NOTE: In addition to the standards and regulations mentioned above, there are numerous regulations and machine safety standards that apply to specific industries. For assistance in obtaining copies of any of these standards, contact Banner at the address or numbers listed at the bottom of page 6. Clearwater 4 Tech - Phone: Fax: Web: [email protected]
8 Important Application Information Prevention of False Actuation Any anti-tiedown control must be designed to prevent accidental actuation. Anti-tiedown circutry must be designed to ignore false input signals. False signals include (but are not limited to) voltage transients, contact "bounce", and EMI or RFI "noise". If a PLC or any other solid-state controller is used to provide anti-tiedown, the design must assure that short duration signals (typically any signals less than a few milliseconds) are ignored. There are several manufacturers of anti-tiedown logic modules which include circuitry to minimize the possibility of false actuation. Definitions: Two-hand Trip (Control): A control that requires the operation of two separate control actuating devices by a machine operator's hands for initiation of a machine cycle. Anti-tiedown (Control): A two-hand trip control configured so that both of the operator's hands must be removed and then reapplied to the control actuating devices to start another machine cycle. (Also called "anti-defeat" control.) Ordering Information: OPTO-TOUCH Optical Touch Buttons are shipped with a black field cover, as standard. A black field cover will be received if the OPTO-TOUCH is ordered by its model number (only). Red, yellow, or green field cover may be specified instead by ordering the OPTO-TOUCH using the appropriate 5-digit part number from the table, below. Field covers may also be ordered separately (page 3). 120V ac 220/240V ac 20-30V ac or dc 10-30V dc SPDT relay NPN (sinking) PNP (sourcing) Attached 6-foot cable Quick disconnect Model OTBA5 OTBB5 OTBVR81 OTBVN6 OTBVP6 OTBA5QD OTBB5QD OTBVR81QD OTBVN6QD OTBVP6QD OTBA5L OTBB5L OTBVR81L OTBVN6L OTBVP6L OTBA5LQD OTBB5LQD OTBVR81LQD OTBVN6LQD OTBVP6LQD Lexan upper housing Polysulfone upper housing OPTO-TOUCH Optical Touch Buttons Part Numbers - Momentary Action Models Black NOTE: Banner Optical Touch Buttons are manufactured and sold under license for U. S Patent #4,939,358. Red Yellow Green WARRANTY: Banner Engineering Corporation warrants its products to be free from defects for one year. Banner Engineering Corporation will repair or replace, free of charge, any product of its manufacture found to be defective at the time it is returned to the factory during the warranty period. This warranty does not cover damage or liability for the improper application of Banner products. This warranty is in lieu of any other warranty either expressed or implied. 5
9 OPTO-TOUCH OTBVR81 Series Momentary Action 20-30V ac or dc Optical Touch Buttons Banner OTBVR81 Series Optical Touch Buttons are touch-activated photoelectric switches designed to replace capacitive touch switches and mechanical push buttons. The OPTO-TOUCH's SPDT electromechanical relay is activated for as long as a finger, introduced into the "touch area" (yoke) of the switch, interrupts the OTB's infrared sensing beam. Banner OTBs are ergonomically designed to eliminate the hand, wrist, and arm stresses associated with mechanical push buttons. They require absolutely no physical pressure to operate. LED indicators light for "power on" and "output activated". OTBs are highly resistant to EMI, RFI, and ambient light interference, and are constructed from black polysulfone and VALOX for reliability in industrial environments. The 30-mm threaded base provides easy mounting, and OTBs are easily retrofitted to existing machines. See page 2 for available models. Specifications Supply Voltage: 20 to 30V ac or dc (25 milliamps, maximum). Output Configuration All models SPDT electromechanical relay (one N.O. contact, one N.C. contact). Output Rating Maximum voltage is 250V ac or 30V dc. Maximum current 7 amps (resistive load), 1 HP max. Minimum load 100mA at 24V. Mechanical life of relay 50,000,000 operations (minimum). Electrical life of relay 100,000 operations (min.) at full resistive load. Transient suppression is recommended when switching inductive loads. Dimensions Model shown has built-in, attached cable. See page 2 for QD-style base. Lexan VALOX iare registered trademarks of General Electric Company. OTBVR81 Series Momentary Action Optical Touch Button (QD model shown) Ambient Light Immunity: 120,000 lux (direct sunlight). EMI/RFI Immunity: The OPTO-TOUCH is highly resistant to both single and mixed EMI and RFI noise sources. Operating Temperature Range: -20 to +50 C (-4 to +122 F). Indicator LEDs: two indicator LEDs. One lights when power is "on"; the other lights when the infrared sensing beam is interrupted. Construction: Black polysulfone cover and fiber-reinforced VALOX base. Electronics fully epoxy-encapsulated. Totally sealed, non-metallic enclosure. The OTB's threaded base has M30 x 1,5 external threads and 1/2" NPSM internal threads. Base requires a 1-3/16" diameter mounting hole (fits most standard automotive-size "jumbo" legend plates and oiltight pushbutton holes). OPTO-TOUCH OTBs are rated NEMA 1, 3, 4, 4X, 12, and 13. Cable: Quick-disconnect (QD) models require model MBCC conductor cable (purchased separately). QD cables are 12 feet long. Models with attached cable (non-qd models) are supplied with 6 feet of PVC-jacketed, 22 AWG 5-conductor cable. Environmental Considerations: Prolonged exposure of the OPTO-TOUCH to direct outdoor sunlight will cause embrittlement of the polysulfone cover. Window glass effectively filters longer wavelength ultraviolet and provides excellent protection from sunlight. Where protection from direct sunlight is not possible, consider special-order models with Lexan covers (see the other side of this sheet for information). Cleaning Information: OPTO-TOUCHs should be cleaned periodically using alcohol, glass cleaner, or a mild soap solution and a soft cloth. Avoid the following substances, as they will attack polysulfone to varying degrees: esters, ketones, aromatic hydrocarbons, and chlorinated hydrocarbons. WARNING. Banner OPTO-TOUCH OTB Series Optical Touch Buttons are intended as generalpurpose initiators, and are not safety devices. Like most solid-state devices, they are as equally likely to fail in the conducting ("on") state as in the non-conducting ("off") state. If OPTO-TOUCH Optical Touch Buttons are used to initiate machines or operations in which false operation of an Optical Touch Button could be dangerous, pointof-operation guarding devices or related safety controls must be installed and maintained to meet all appropriate OSHA regulations and ANSI B11 machine safety standards. P/N 33109
10 OPTO-TOUCH OTB Mounting Hole Information The OPTO-TOUCH has a 30 millimeter threaded base which fits directly into a standard mounting hole for an oiltight push button. A lock ring, supplied with each OPTO-TOUCH, may be used to prevent switch rotation. The mounting hole details shown at the right are used for the OPTO- TOUCH and also for standard oiltight push buttons and their legend plates. The drawing at the far right shows how to approximate the keyway using a drill hole. Quick Disconnect (QD) Option (order model MBCC-512 cable) Cable connector, end view Cable connector, side view (MBCC-512 cable): (MBCC-512 cable): Standard models with polysulfone cover Models OTBVR81 Standard model with polysulfone cover and 6-foot attached cable. OTBVR81QD Standard model with polysulfone cover and QD-style base (requires MBCC-512 cable). OTB base, side and end views: Special-order models with Lexan cover OTBs with Lexan cover are available by special order for use in direct sunlight. Lexan models should be avoided for certain environments, as explained below. Models OTBVR81L OTBVR81LQD Special model with Lexan cover and 6-foot attached cable. Special model with Lexan cover and QD-style base (requires MBCC-512 cable). Hookup Information: 20 to 30V ac or dc Environmental Considerations for Lexan models: Prolonged exposure to hot water and moist high-temperature environments (above 150 F or 66 C) should be avoided. Aromatic hydrocarbons (such as xylene and toluene), halogenated hydrocarbons, and strong alkaline materials should be avoided. Lexan OPTO-Touchs should be cleaned periodically using a mild soap solution and a soft cloth. Avoid strong alkaline materials, as they will attack Lexan to varying degrees. NOTE: dc power is applied without regard to polarity. WARRANTY: Banner Engineering Corporation warrants its products to be free from defects for a period of one year. Banner Engineering Corporation will repair or replace, free of charge, any product of its manufacture found to be defective at the time it is returned to the factory during the warranty period. This warranty does not cover damage or liability for the improper application of Banner products. This warranty is in lieu of any other warranty either expressed or implied. Banner Engineering Corp th Avenue No., Minneapolis, MN Telephone: (612) FAX (applications): (612)
OPTO-TOUCH OTB Series
OPTO-TOUCH OTB Series Momentary Action Optical Touch Buttons Banner Optical Touch Buttons are touch-activated photoelectric switches designed to replace capacitive touch switches and mechanical push buttons.
MULTI-BEAM LS10 Light Screen System
For Sensing Small Parts at High Speeds Emitter and receiver pair produce a strobed array of modulated light beams to produce a light screen Simple, economical and highly reliable means of sensing small
LED...A70..4-..Q Series Sealed High-Intensity
LED...A70..4-..Q Series Sealed High-Intensity Area Lights High-Power Lighting for use with PresencePLUS and Other Vision Systems Features Rugged, waterproof housing, rated IEC IP68 Compact area light for
Machine Safety Switches
Machine Switches SI-LS31H Series 31 mm Limit-Switch-Style with Hinged Lever Actuators Features Limit switch design (EN 50047) For use on doors or flaps Positive opening safety contacts (IEC 60947-5-1)
WORLD-BEAM QS30 Sensors
Datasheet High-Power Opposed-Mode Sensors Infared beam with high excess gain range of over 213 m (700 ft) Excellent noise immunity Excellent for applications ere high sensing power is required due to long
Miniature High-Resolution Registration Mark Sensor White LED AUTOSET Remote Setup Option
REGISTRATION MARK SENSORS MARK EYE PRO 2 Miniature High-Resolution Registration Mark Sensor White LED AUTOSET Remote Setup Option Registration Mark Photoelectric Sensors 2-115 High-Resolution Registration
Machine Safety Switch: SI-LM40 Series Limit Switch Style
Machine Switch: SI-LM40 Series Limit Switch Style SI-LM40 Series Limit Switch Style with Flexible In-Line Actuator Positive-opening safety contacts (IEC 60947-5-1) (not dependent upon springs) Standard
HOW TO ORDER SAFETY PRODUCTS/SAFETY CONTROL SYSTEMS ELECTRICAL SAFETY CONTROLS
HOW TO ORDER SAFETY PRODUCTS/SAFETY CONTROL SYSTEMS PNEUMATIC SAFETY CONTROLS BASIC CONTROLS SC3000 - SELF CONTAINED 2 HAND CONTROL - STAND ALONE MODEL SC3300 - SELF CONTAINED 2 HAND CONTROL - PRESS READY
Color Mark Sensor with Red or Green LED E3S-VS
Color Mark Sensor with Red or Green LED Rugged IP67 Color Mark Sensor 1 ms response time Detects a wide variety of color marks PNP or NPN output ls Light-on/ Dark-on operation, wire selectable Vertical
Advantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
For the latest technical information about this product, including specifications, dimensions, and wiring, see www.bannerengineering.
VALU-BEAM 92 Series AC- and DC-powered sensors with solid-state outputs For the latest technical information about this product, including specifications, dimensions, and wiring, see www.bannerengineering.com
Centro-Matic Automatic Lubrication Systems System Controls
Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the
OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS
OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS Photoelectric These sensors use light sensitive elements to detect objects and are made up of an emitter (light source) and a receiver. Four types of photoelectric
Capacitive Prox E2K-X
Capacitive Prox Threaded, Cylindrical Sensor Detects Metallic and Non-metallic Objects Permits non-contact detection of metallic and non-metallic objects such as glass, wood, water, oil and plastic Allows
Smart Sensing Solutions Since 1954
Smart Sensing Solutions Since 1954 X-tremely High Speed Photoelectric Registration Sensor 800-237-0946 ttco.com 813-886-4000 Photoelectric Registration Sensor The SMARTEYE X-MARK TM is the fastest, most
Small U-shaped Micro Photoelectric Sensor. Enables space saving and quick installation!
4 Small Micro Photoelectric Amplifier Built-in PM-44 SERIES PM-4 SERIES General terms and conditions... F- selection guide... P.44~ Related Information Glossary of terms / General precautions... P.39~
When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Samba OPLC SM35-J-R20 Installation Guide The Unitronics SM35-J-R20 offers the following onboard I/Os: 12 Digital Inputs, configurable via wiring to include: 1 HSC/Shaft-encoder Input, 2 Analog inputs (only
EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications
EXLUX ECOLUX C-LUX LIGHTING 6000 6008 6400 6408 6600 6608 6500 Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications Features: Electronic Ballasts For Fluorescent Bipin
Short Range Wireless Switch System Handheld 8 Installation and Operations Guide
Phone: (866) 701-1146 Fax: (425) 216-7558 www.remotecontroltech.com Short Range Wireless Switch System Handheld 8 Installation and Operations Guide Introduction... 2 Before Installation... 2 Receiver Installation...
Cross-beam scanning system to detect slim objects. 100 mm 3.937 in
891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC
12-Volt 10-Amp Regulated Power Supply
22-506.fm Page 1 Friday, August 6, 1999 12:55 PM Cat. No. 22-506 OWNER S MANUAL Please read before using this equipment. 12-Volt 10-Amp Regulated Power Supply 22-506.fm Page 2 Friday, August 6, 1999 12:55
PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description
Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.
HM-W536 Install Guide
HM-W536 Install Guide 9/13/2013 IMPORTANT SAFETY INSTRUCTIONS Warning - When using electrical devices, basic safety precautions should be followed to reduce the risk of fire, electrical shock or injury.
USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920
USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920 [This page intentionally left blank] Warning for Your Protection 1. Read these instructions. 2. Keep these
Universal Voltage Terminal Photoelectric E3JM
Universal Voltage Terminal Photoelectric Universal AC/DC Photoelectric Sensor with Built-in Timer Easy-to-wire terminal block Built-in timer offers selectable ON-delay, OFF-delay and one-shot Relay or
Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles
Clear Glass Sensor Optimum Sensor for Detecting Transparent Glass and Plastic Bottles E3S-CR67/62 Retroreflective Sensor smoothly detects 5-mm gaps. Detects transparent bottles that have a lens effect.
U-shaped Micro Photoelectric Sensor
SERIES U-shaped Micro Photoelectric Extremely small size enables space saving and quick installation! Extremely small Ultra-small type PM- 24(-R) contributes to the miniaturization of your equipment. Even
OPL BASIC. Dosing System for Professional Laundry machines. Contents
OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page
SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function
SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function Document No. 155-751 SKP15U.. Description Only when assembled to Series VGU Gas valves SKP15 electro-hydraulic actuators combine with
Super Slider ADJUSTABLE FROM 3.5-12 Model #HD26229
Super Slider ADJUSTABLE FROM 3.5-12 Model #HD26229 IMPORTANT!!! ALL PERSONS USING THIS EQUIPMENT MUST READ AND UNDERSTAND ALL INSTRUCTIONS. FAILURE TO DO SO MAY RESULT IN SERIOUS INJURY OR DEATH. USERS
Water Leak Detection System
Water Leak Detection System Installation and Operating Manual 505-334-5865 ph 505-334-5867 fax www.rodisystems.com email:[email protected] 936 Highway 516 Aztec, NM 87410-2828 Manual Revisions and Copyright
OPLC Installation Guide
Samba OPLC SM43-J-T20/ SM35-J-T20 OPLC Installation Guide 12 Digital Inputs, include 1 HSC/Shaft-encoder Input, 2 Analog inputs (only when the digital inputs are set to pnp), 8 Relay Outputs 12 Digital
VERTICAL / FIXED BEAM CLAMP I-BEAM ANCHOR ADJUSTABLE FROM 4-14 Model # HD26249
VERTICAL / FIXED BEAM CLAMP I-BEAM ANCHOR ADJUSTABLE FROM 4-14 Model # HD26249 IMPORTANT!!! ALL PERSONS USING THIS EQUIPMENT MUST READ AND UNDERSTAND ALL INSTRUCTIONS. FAILURE TO DO SO MAY RESULT IN SERIOUS
Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m 32.808 ft (Red LED)
NX SERIES Compact Multi-voltage Photoelectric Power Supply Built-in Multi-voltage photoelectric sensor usable worldwide Conforming to ow Voltage and EMC Directive Multi-voltage The NX series can operate
Smile 11 AS-i Emergency stop with safe AS-i input node
Original instructions Smile 11 AS-i Emergency stop with safe AS-i input node SAFETY AT WORK ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand
sensors Miniature Sensors - S100 The universal miniature photoelectric sensor
Miniature Sensors - S1 The universal miniature photoelectric sensor Two threaded front mounting holes Two slotted rear mounting holes Anti-tampering sensor (no adjustment) Standard optic functions and
Model 201 Wiegand Touchpad Reader Installation Guide
Model 201 Wiegand Touchpad Reader Installation Guide P/N 460353001C 15AUG11 2011 UTC Fire & Security. All rights reserved. This document may not be copied in whole or in part or otherwise reproduced without
PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357
Series Features: Color coding and pin configuration makes it physically impossible to mate plugs and receptacles of different voltages and current ratings (per IEC 60 309-2). Interlocked switch mechanism
LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL
EPSOLAR LS1024B / LS2024B/ LS3024B Solar Charge Controller USER MANUAL Thank you very much for selecting our product! This manual offers important information and suggestions with respect to installation,
Liquid Leakage Sensor Amplifier
9 Liquid Leakage Sensor Amplifier Space-saving Sensor Amplifier reliably detects a wide variety of liquids ranging from water to chemical liquids with low conductivity 1 Detects leakage of liquid such
EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws
Compact Pre-wired Photomicrosensor with Built-in Amplifier (Non-modulated) CSM DS_E_7_2 Meeting Customer Needs with Compact Sensors that Mount with M Screws Both light-on and dark-on outputs provided.
Instructions A622 100 Amp AC/DC Current Probe 070-8883-03
Instructions A622 100 Amp AC/DC Current Probe 070-8883-03 Revision A www.tektronix.com 070888303 Copyright Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents,
EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.
Wafer-carrier Mounting Photomicrosensors EE-SPY1/ CSM_EE-SPY1 DS_E_3_ Photomicrosensors for detecting wafer-carrier mounting. The mounting position is set with a pedestal. The contact surface with the
How To Use A Cdm250 Digital Multimeter
User Manual CDM250 Digital Multimeter 070-6736-03 Copyright Tektronix, Inc. 1987. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this
SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors. 40-300 mm background suppression
Advanced line of miniature Asian style of photoelectric sensors 4-3 background suppression.7 m proximity, 15 with narrow beam 4 m polarized retroreflective 3 m LASER through beam Standard 3-wire output
Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps
Solar Home System User Manual AEHSHS0110W2L Solar Home System 2 Lamps All rights reserved Specifications subject to change without prior notice 2 Dear Customer, Thank you for purchasing Schneider Electric
Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.
Model Number Features Very small housing High climatic resistance 4 Bit multiturn Analog output Surge and reverse polarity protection Description This absolute rotary encoder with internal magnetic sampling
Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications
Compact size and high performance for the most challenging detection applications Compact dimensions (14x42x25 mm) Background suppression for transparent and shiny objects High speed contrast sensor up
QR12 (1.22 ) Diameter Optical Encoder
Improving the Quality of Life through the Power in Light QPhase QR12 (1.22 ) Diameter Optical Encoder Design Features: Low profile assembled height of Bearing design simplifies encoder attachment Resolutions
OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS
Manual No. BLWR043 Rev. 4 September 2012 OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS CVF-8AC CVF-8AC50 CVF-6ACAN CVF-15ACAN CVF-25ACAN CVF-8A15KIT CVF-8A25KIT MODELS: CVF-8DC CVF-6DCAN CVF-15DCAN CVF-25DCAN
Operating Instructions. UL325 Compliant Non-monitored
IRB-325 Infrared Photocell UL325 Compliant Non-monitored Operating Instructions This product is an accessory or part of a system. Always read and follow the manufacturer s instructions for the equipment
SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications
Fiber Optic Sensors - S7 Advanced fiber optic amplifiers for high speed and low contrast applications DIN rail mountable models with dual digital displays speed models: 2 μs...5 ms Super high speed models:
INSTALLATION INSTRUCTIONS
LIGHTING CONTROL PANELS 4 AND 8 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.
543-0032-00, 943-0032-00. User s Manual
543-0032-00, 943-0032-00 User s Manual 1 Comfort Alert Diagnostics Faster Service And Improved Accuracy The Comfort Alert diagnostics module is a breakthrough innovation for troubleshooting heat pump and
Reliance DuraStar ORDINARY LOCATION INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS
STORAGE and HANDLING The LED Illuminator meets or exceeds all applicable specifications when shipped from the factory. All units should be inspected upon receipt to ensure that no damage has been incurred
Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D104 706114 / 00 01 / 2012
Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D104 706114 / 00 01 / 2012 Contents 1 Preliminary note 3 1.1 Symbols used 3 1.2 Warning signs used 3 2 Safety instructions
330505 Low Frequency Velocity Sensor
330505 Low Frequency Velocity Sensor Bently Nevada* Asset Condition Monitoring Description The Bently Nevada Low Frequency Velocity Sensor is designed to measure absolute (relative to free space) bearing
OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER
OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER P110 Your battery charger has been engineered and manufactured to Ryobi s high standard for dependability, ease of operation, and operator safety. When properly
Infrarot-Bewegungsmelder IP44
Infrarot-Bewegungsmelder IP44 infrared motion sensors IP44 ODA (weiß) slim ODA (schwarz) slim 95174 96000 ODA (weiß) ODA (schwarz) 95175 96001 Betriebsanleitung User s Manual User s Manual infrared motion
Silvertel. Ag5200. 1 Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power
Silvertel V1.1 November 2012 Datasheet Pb 1 Features IEEE802.3at and IEEE802.3af compliant Maximum 30W output power Dual In-Line (DIL) package size 50.6mm (L) x 30mm (W) Overload, short-circuit and thermal
MAC FAUCETS. Owner s Manual. Models: FA444
MAC FAUCETS Owner s Manual Models: FA444 Installation procedure: 1. Take a moment to view drawings and read special Installation note on page 3 of this manual before proceeding with installation. Connect
Single Phase Soft Starter
Single Phase Soft Starter Installation & Operating Manual 6/02 Table of Contents Section 1 General Information................................................... 1 1 General Description................................................
PART 1 - INTRODUCTION...
Table of Contents PART 1 - INTRODUCTION... 3 1.1 General... 3 1.2 Sensor Features... 3 1.3 Sensor Specifications (CDE-45P)... 4 Figure 1-1 CDE-45P Sensor Dimensions (standard, convertible style)... 4 PART
Mobile Data Power Model: MDP-25
Mobile Data Power Model: MDP-25 Topic Section Features... 2 Operational Features Summary... 2 Back-up Battery Power Internal Charger Voltage Spike Protection RF Noise Filtering Warning of Imminent Loss
Original instructions Tina 3A/Aps Adaptor unit
Original instructions Tina 3A/Aps Adaptor unit ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this
StorTrends 3400 Hardware Guide for Onsite Support
StorTrends 3400 Hardware Guide for Onsite Support MAN-3400-SS 11/21/2012 Copyright 1985-2012 American Megatrends, Inc. All rights reserved. American Megatrends, Inc. 5555 Oakbrook Parkway, Building 200
Product Specification instalert Rapid Messenger Variable Message Sign
instalert 2 units to cover any application instalert 18 (ia18): 18 x 28 full matrix instalert 24: (ia24): 24 x 60 full matrix Size, Weight without battery ia18: 30 x 20 x 2.74, 29 lbs ia24: Folds to fits
Features. High Brightness LED Light source
www.edison-opto.com Solid-State Lighting Series 6W MR16 DATASHEET Features High Brightness LED Light source Ecologically Friendly Energy Efficient General Information... 1 Product Dimensions... 2 Product
0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N
55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils
Adjustment functions for both span and shift have been incorporated
SENSORS FOR SERIES LED Type Wafer Alignment Sensor FX-0-F FT-F9 FD-F7 EX-F70/F60 M SH-7 FD-L4 M-DW The use of a safe LED light beam now allows for high precision detection with a resolution of 0!m (.8
W150: Miniature photoelectric switch series with completely integrated electronics
Product group W50 Photoelectric proximity switch BGS Photoelectric proximity switch energ. Photoelectric reflex switch W50: iniature photoelectric switch series with completely integrated electronics Through-beam
WIND ALARM. Wind Speed Alarm. Wind Speed. Set Point 2. Set Point 1 NEW BEDFORD, MA 02745 USA
Thank you for purchasing the Maximum wind speed alarm. The Maximum wind speed alarm is a dual set point wind speed indicator with a two digit LED display. It contains a yellow light to display one set
12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations
12S, 14S, 15S Series Time Delay Relays and Sequencers Time Delay Relays and Sequencers The Therm-O-Disc type 12S, 14S and 15S series time delay relays and sequencers are field-proven devices for controlling
Tina 2A/B Adaptor unit
Original instructions Tina 2A/B Adaptor unit ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this
BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets
BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets Any Application. Any Environment. Code No: 0816407 Rev. 4 (07/12)
Electronic, Digital and Mechanical Vibration Switches
PT500 Electro-Mechanical Vibration Switch Introduction The PT500 is an economical solution that provides basic vibration protection for rotating reciprocating machines. The PT500 uses an inertia sensitive
I STAR COMPUTER CO., LTD
I STAR COMPUTER CO., LTD Mini Redundant Power Supply 300W+300W for IPC-Computer Model No. TC-300R8 Table of content 1. Introduction...1 2. Specification 2.1 Input Voltage...1 2.2 DC Output...1 2.3 PS-ON
MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation
MTE SERIES RLW World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930 2009 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RLW reactors are components designed to improve the reliability
RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05
RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,
Part I - Installation
400 Series Pressure and Differential Pressure Switches Types: H400, H402, H403, H400K, H402K, J400, J402, J403, J400K, J402K UNITED ELECTRIC CONTROLS Installation and Maintenance Instructions Please read
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support
PM SERIES. Extremely small size enables space saving and quick installation! U-shaped Micro Photoelectric Sensor. Extremely small
EQ-00 VF NX MS-AJ RT-0 PX- CY PHOTOELECTRIC SENSORS Mounting Stand SERIES U-shaped Micro Photoelectric PNP output type available Extremely small Ultra-small type -4(-R) contributes to the miniaturization
Mini Breakout-Board. CNC Interface for LPT Port. Installation Manual Version 4
Mini CNC Interface for LPT Port Version 4 Product Brief This breakout-board is designed to connect up to four stepper or servo drives to the parallel port of a PC. This requires the use of a CNC controller
CQM1-SF200/CS1W-SF200
Safety Relay Unit ( I/O Unit Type) CQM1-SF200/CS1W-SF200 CSM_CQM1-SF200_CS1W-SF200_DS_E_2_1 A Safety Relay Unit That Functions as a I/O Unit. Less Installation Space and Wiring Required. Safety Relay Unit
Laser diffuse reflection light scanner with background suppression. Dimensioned drawing
Specifications and description HRTL 3B Laser diffuse reflection light scanner with background suppression Dimensioned drawing We reserve the right to make changes DS_HRTL3B_en.fm en 01-2010/12 50114049
ETZGAR CONVEYOR COMPANY Controls Section v12.05
Section 7 Controls Page Description 7-1 Controls Index 7-2 Motor Data, Enclosure Rating and Abbreviations 7-3 Controls Safety Guidelines 7-4 Fixed Speed Controls Packages 7-5 Three Phase AC Variable Speed
DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D
ELECTRONICS AB DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D & HIGH&VOLTAGE& FIXED&GAIN& BROADBAND & 800Vpp&60mA& 100x& DC&to&ca&200&kHz & LOW&OUTPUT&IMPEDANCE& HIGH&SLEW&RATE &
IH 17025 E Sigma Island 90
INSTRUCTIONS FOR USE Kitchen extractor hood Type: IH 17025 E Sigma Island 90 Dear Customer!! You are now a user of the newest generation kitchen extractor hood type IH 17025 E Sigma Island 90. This hood
MIC-WKT and MIC-WKT-IR
MIC-WKT and MIC-WKT-IR Installation Manual Bosch Security Systems EN Installation and Operation Manual MIC-WKTI and MIC-WKT-IR Installation Manual EN 2 MIC-WKT and MIC-WKT-IR Washer Pump Drive Card Kits
OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE
OASIS-PLUS 120V INFORMATION & OPERATING INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE 56041852 WARNING:
SSW-iLM Keypad. Wire Harness Configuration. Note: This product is designed to be installed and serviced by security and lock industry professionals
SSW-iLM Keypad Note: This product is designed to be installed and serviced by security and lock industry professionals Specifications Case dimensions: 6 1/2 L x 1 3/4 W x 1 1/8 D Electrical: 5-12VDC Only
General 1-2-Opto-electronics Safety Switches 4-Emergency
General 1-2-Opto-electronics Safety Switches 4-Emergency Logic Power The Lifeline 4 cable/push button operated system can be installed along or around awkward machinery such as conveyors and provide a
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points
Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection
E3T Miniature Photoelectric Sensors
E3T Miniature Photoelectric Sensors Ultra-Compact with Visible Red Beam»» Ultra slim to fit and perform where others won't»» Visible red beam for simple set-up»» Five different sensing methods E3T Miniature
Comfort Control Relay Panel (CCRP)
CCRP9 "Commitment to Innovation" OPERATION & INSTALLATION GUIDE FOR Comfort Control Panel (CCRP) Off-Peak System Control 9 Pole CCRP 4 Pole CCRP (Applicable to Software Version 14.0-14.9) "Manufactured
Screen 3.5" Color Touch 4.3" Color Touch Keypad or Function Keys Programming Com Port, Built-in
Samba PLC+HMI SM35-J-RA22 SM43-J-RA22 Installation Guide 12 Digital Inputs, including 1 HSC/Shaft-encoder Inputs, 2 Analog Inputs, 2 PT100/TC inputs 8 Relay Outputs 2 Analog Outputs General Description
E3Z. Ordering Information. Photoelectric Sensor with Built-in Amplifier. Compact Sensor Offers Long Sensing Distance and Superior Noise-Immunity
Photoelectric Sensor with Built-in Amplifier Compact Sensor Offers Long Sensing Distance and Superior Noise-Immunity H Photo-IC provides long sensing distance: 15 m for through-beam, 4 m for retroreflective,