WHITE PAPER ANSI/TIA-606-B
|
|
|
- Douglas Wheeler
- 9 years ago
- Views:
Transcription
1 WHITE PAPER ANSI/TIA-606-B
2 BACKGROUND American National Standards Institute (ANSI) Telecommunications Industry Association (TIA) Electrical Industries Alliance (EIA) International Standards Organization (ISO) International Electrotechnical Commission (IEC) ANSI/TIA-606-B is designed to be a generic labeling standard that applies to all types of premises. The standard is backward compatible with the legacy ANSI/TIA/EIA-606-A Addendum 1 and is compatible with the international standard ISO/IEC TR identifiers. The original TIA-606-A was designed to identify and record the general administration, but did not address the specific needs of the data center design and installation. TIA-606-A was just reaffirmed back in The TIA-606-A Addendum 1 was published in The addendum reconciled the 606-A with the TIA s 942 data center standard. The current 606-A did not really consider data centers and the 942 did not consider administration. The two concepts came together in Addendum 1 to the 606-A. The development of the ANSI/TIA-606-B combined the TIA-606-A and the Addendum 1 while harmonizing with the requirements of the ISO/IEC TR Labeling is a key factor in the installation and maintenance of an efficient and professional installation. The 606 standard continues to expand and address how and where to identify key components of Information Transport System (ITS). The new 606-B standard not only services the data center, but also commercial, residential, industrial and healthcare facilities. It now establishes guidelines for owners, end users, manufacturers, consultants, contractors, designers, installers, and facilities administrators involved in the administration of the telecommunications infrastructure. In addition, by harmonizing with ISO/IEC TR , the updated standard can be implemented internationally. The new standard is meant to increase the value of the system owner s investment by reducing labor costs associated with maintaining complex infrastructure systems, which results in extending the useful economic life of the system and by providing effective service to the users in a variety of industries, markets and international countries. 2
3 CHANGES FROM THE LAST REVISION 1. Adopts identification scheme specified in TIA-606-A Addendum Allows existing TIA-606-A identifier formats to continue to be used where they are already in use. NOTE: An identifier is simply the printed text that will appear on a label as related to the standard. 3. Harmonized with ISO/IEC Creates new identification format for Cabling Subsystem 1 link identifiers (Horizontal links), Cabling Subsystem 2 and 3 links (Backbone cables) as well as telecommunications outlets, equipment outlets, splices, consolidation points and outdoor telecommunication spaces. NOTE: In order to be generic to all types of premises, terminology was adopted from the TIA-568-C.O. standard in which Cabling Subsystem 1 is now what was commonly referred to as the Horizontal Link. The (1) does not mean anything in particular except to differentiate Cabling Subsystem 1 links from Cabling Subsystem 2 and 3 links which we commonly referred to as Cross Connects or Backbone cables. Campus cabling has its own cabling separate from the cabling subsystem 2 and 3 links, which are the 2 layers of backbone cabling allowed in premises cabling. The standard allows one level of cross connection in Cabling Subsystem 1 and two levels of cross connection in Cable Subsystem 2 and 3 cabling. Clause The language also makes the standard more generic in that it not only can service the data center, but can also service commercial, residential, industrial and medical facilities. 5. Extends administration to all inter-building telecommunications cabling. 6. Creates new identifiers for telecommunications outlets, equipment outlets, splices, consolidation points and outdoor telecommunication spaces (maintenance holes, pedestals, hand holes, etc.). 7. Administers Cabling Subsystem 2 and 3 links by pair groups, corresponding to ports (pairs, strands and grouping identifiers) rather than copper pairs or single fibers. See clause Administration of grounding and bonding systems beyond the TMGB and TGB. 9. Provides information on implementing automated infrastructure management systems. 3
4 THE BASICS CLASSES The standard still breaks out the criterion by classes of administration. CLASS 1 = Locations served by a single Equipment Room (ER) This ER is the only Telecommunications Space (TS) administered whereas there are no Telecommunication Rooms (TRs) and no Cabling Subsystem 2 and 3 cabling or outside plant cabling systems to administer. CLASS 2 = Fulfils the administration needs of a single building that are served by multiple Telecommunications Room (TR)s with one or more TR s within a single building. This includes all the elements of a class 1 system plus identifiers for Cabling Subsystem 2 and 3 cabling, multi-element bonding and grounding systems and fire stopping. CLASS 3 = Serves a campus environment with multiple buildings and building pathways, spaces, and outside plant elements. CLASS 4 = Attends the needs of a multi-site (multi-campus) administration. There are slight differences in requirements depending on what level is administered. In a Class 1 system, for example, the floor and room number do not need to be identified since there is only one room to manage. Obviously, as the complexity of the system increases, additional identifiers are needed. In Class 3 and 4 systems there are added requirements, such as building and campus identifiers, outside plant and inter-campus elements such as wide area network connections. The basic premise of the TIA-606-B compliant data center implementation is actually very simple and can be broken down using a few common examples. A typical patch panel and port identifier might be as follows: 1A.AD02-40:02 1A. = Floor 1, room A AD02 = The grid location within the data center for a particular rack or cabinet -40 = A patch panel located 40 rack units from the bottom of that rack or cabinet :02 = A specific port within the patch panel located at AD (This can also be a range of ports as example) Optionally, we can remove the space location to the front of this identifier. If we are on floor 1, space A, and this is the only space, there is no need to include that portion on the printed identifier. The actual printed identifier might look as follows: AD02-40:02 Since we are harmonizing to the ISO/IEC TR , we can optionally add a + sign which specifies that the next portion of the identifier is a location aspect. The + sign only needs to appear in the records section and not on the actual label. +AD02-40:02 An = in front of an identifier specifies a function aspect (Example: = XO for telecommunications outlet). 4
5 SPACE LABELING 1A = Floor 1, Space A, which is a alpha-numeric sequence that can be edited to suit the needs of the installation. Example: 3TRA would represent Telecom Room A on the third floor. An example of an ISO/IEC TR compatible format is: +3TRA. CABINET AND RACK IDENTIFIERS The standard recommends the use of GRID COORDINATES to distinguish the rack or cabinet in a space. In rooms that have access floor systems, recognition for the space shall employ the access floor grid identification scheme using alpha and numeric characters to mark the X and Y coordinates within the space. X COORDINATE AA AB AC AD AE AF AG AH AI AJ AK AL AM AN AO AP AQ AR AS AT AU AV AW AX AY AZ BA BB Y COORDINATE So, a rack located at grid coordinates AD02, would be marked as ADO2. Typically, the label is placed on the top and bottom, front and rear of the rack or cabinet using machine printed labels. Where grid coordinates are not used, the racks can be marked by row and rack number. 5
6 PATCH PANEL IDENTIFIERS Within each rack, there will be patch panels. The patch panels shall be labeled with the identifier of the patch panels at the far end of the cables, if practical. These should be marked using rack units from the bottom of the cabinet. Since the floor/space marking is optional in a Class 2 system, the rack and panels can be marked by simply combining the grid coordinates of the rack with the rack units of the panels within that rack. A patch panel 35 rack units from the bottom of a rack located at grid coordinates AD02 would be identified as AD Rack unit position from bottom of usable space in cabinet or rack Fiber Patch Panel Fiber Patch Panel Panel AD02-45 Panel AD02-41 Panel AD02-35 Panel AD02-31 Panel AD02-27 Panel AD02-23 Panel AD02-19 Panel AD02-15 Panel AD02-11 Panel AD02-07 NOTE: The standard also allows the marking of panels and sub-panels using alpha characters starting with A and excluding I, O and Q as outlined in sections and
7 PATCH PANEL PORT IDENTIFIERS TIA PN-606-B, (to be published as The patch panels should be labeled with the identifier of the patch panels at the far end of the cables, if practical. Each port, the first port or the last port, or the last of each subpanel shall be labeled. Patch panel labels shall contain the patch panel identifier. Where space permits, the patch panel also should have labels to specify the classification at the far end ports using this format. Each panel will ANSI/TIA-606-B) have a series of ports that need to be acknowledged UTP cables to the patch panel 42U Thus, from a typical the bottom patch panel/port of cabinet identifier AG06, on ports a set of six ports within the patch In figure 10, the labels below each grouppanel of six might ports be includes marked as: the local and far-end patch panel and port identifiers. AD02-35 p to AG03-35 p This can be interpreted as the near end set of six port as being located in a patch panel 35 rack units from the bottom of rack or cabinet at grid location AD02 and these ports are going to the far-end set of six ports located in a patch panel 35 rack units from the bottom of rack or cabinet at grid location AG NOTE: The near end room name and near end patch panel identifier can be Figure 10 Labeling example omitted for since UTPthis patch information panelis with implicit label and fields inferred from the required cabinet/ rack and patch panel labels. See section The far end room name Figure 11 provides an example of labeling may for also a UTP be omitted patchif panel the far-end that patch does panel not have is in the a same room. This means manufacturer-provided label field for thethat patch the panel length identifier. of the identifier can be truncated to save space yet keep the format intuitive to the user. Example: One could shorten the example above to p To AG03-35 p Patch panels that support Cabling Subsystems 2 or 3 should indicate the name of the space; Main Distribution Area (MDA), Intermediate Distribution Area (IDA), Horizontal Distribution Area (HDA) or TR to which the cables run. Section Figure 11 Labeling example for UTP patch panel without patch panel ID label fields Ports to HDA01 AJ17-45 Ports Optical fiber patch panels Section All ports on patch panels and all positions on termination blocks Figure 12 and figure 13 show two ways of labeling a patch panel using or ignoring subpanels. shall be labeled with the corresponding port number or position number and In figure 12, the patch panel has subpanels, but they are ignored for purposes of numbering ports. optionally with additional identifier fields as practical. All subpanels shall be labeled with their subpanel identifier. An example of a sub-panel identifier is usually indicated by an alpha character: 7
8 Certain applications may provide electrical power in addition to data transmission over balanced twisted pair cables. Visual identification of ports with power MAY be accomplished through the use of this symbol. Ports A1-A6 & B1-B6 to AG10-B Ports Ports A1-A6 = Sub panel A, ports A1-A6 Ports B1-B6 = Sub panel B, ports A1-A6 AG10-B = Sub panel B in rack at grid location AG10 Ports = Ports 1 to 12 in sub panel B SPECIALIZED APPLICATIONS The new standard does address unusual and constantly changing circumstances. As an example from section , several manufacturers have come out with cabinets that use zero rack mount space by incorporating vertical rails in the cabinet to save space. In short, additional patch panels reside on either side of the cabinet in a vertical position. In this case, how does one identify these vertical patch panels? A simple way to mark the vertical panels is to use rack units combined with an alpha character for location within the rack or cabinet. The TIA-606-B now designates an additional alpha letter indicating the side as A, B, C, D, or F, L, R, B (Front, Left, Right, Back) as examples. This can be used when Rack Units (RU) are designated. The user can then name the horizontal and vertical patch panels by rack unit. The rack unit of the vertical patch panel is determined by the rack unit location, of the height of the top of the vertically mounted patch (by height at the top). A separate alpha designation for Right (R) or Left (L) to distinguish the vertical patch panels as being either on the left or right side of the cabinet. EXAMPLE: AG09-L35:01-06 In this case, the credential is describing a patch panel at 35 rack units from the bottom of the rack, on the left side of the cabinet, at grid location AG09, ports 1 to 6. Using pre-terminated copper or fiber solutions, Zero U, high density cabinets can allow additional ports where you need them and aligns connectivity with the servers. This allows for moves, adds, and changes without interrupting rack mounted equipment in a fully populated cabinet. This is a new trend in cabinet management to maximize data center real estate and the new TIA-606-B standard is flexible enough to allow proper identification of these vertical panels. 8
9 CABLING SUBSYSTEM 1 LINK / HORIZONTAL LINK IDENTIFIERS The main focus of the 606-B standard is to be able to track the ITS from the data center to the work area. Using the new format, a horizontal link identifier that terminates at both ends on panels within the same data center would be printed as follows: NEAR END = AG09-35:01 / AJ06-35:01 FAR END = AJ06-35:01 / AG09-35:01 If standing at rack location AG09, reading this near end cable identifier will describe both the near end and far end locations. AG09 = Rack or cabinet at grid location AG09 within the data center - 35 = Patch panel located 35 rack units from the bottom in rack AG09 :01 = Port 01 in patch panel located 35 rack units from the bottom of rack AG09 / = Separator for near end/far end location description AJ06 = Rack or cabinet at grid location AJ06 within the data center -35 = Patch panel located 35 rack units from the bottom in rack AJ06 :01 = Port 01 in patch panel located 35 rack units from the bottom of the rack in AJ06 The ISO/IEC TR identifiers would appear as follows for a Cabling Subsystem 1 Link; AG09-35:01 / AJ06-35:01=W The W is the letter code for cables as specified in IEC NOTE: In commercial buildings, industrial premises, data centers and multi-tenant buildings, each individual telecommunications outlet or equipment outlet shall be labeled with the Cabling Subsystem 1 link identifier. The labeling SHALL appear on the connector, faceplate and Multi User Telecommunications Outlet Assembly (MUTOA) in a way that clearly identifies the individual connector associated with the particular identifier. Section In sections to when using the Cabling Subsystem 1 link identifiers, it is optional to identify Equipment Outlets (EO s) and telecommunication outlets (TO s) by using a two letter code to identify the outlet. XO XC XL XSz = Equipment room outlets = Consolidation points = Zoned Distribution Areas (ZDA) ports = Splice where z is the appropriate distance along the cable of the splice from the termination point in the telecommunications room or HDA. An example of a Cabling Subsystem l link identifier using the option to identify the outlet might look as follows: AG09-35:01 / AJ06-35:01=XL:5 The port on the consolidation point may optionally be identified by a colon : and the port after the XL. Figure 4: Option B is using two MPO/MTP connectors side by side with 1 row of 12 9 array fibers on each connector.
10 GROUNDING AND BONDING The standard addresses grounding and bonding beyond the (Telecommunications Main Grounding Busbar) TMGB and (Telecommunications Grounding Busbar) TGB with the optional addition of the (Rack Grounding Busbar) RGB, (Mesh Bonding Network) MBN, (Bonding Conductor for Telecommunications) BCT, (Telecommunications Bonding Backbone) TBB, as well as being able to attach objects such as an identifier for a cabinet or rack or electrical panel as some common examples. See sections to 5.2. A practical example might be a rack grounding Busbar identifier where you may have more than one Rack Grounding Busbar (RGB) in the cabinet rack or wall segment is shown below. 2A=RGB1 2A = Floor 2, Room A RGB = Rack Grounding Busbar #1 The standard also allows the addition of an identifier that identifies an object to which the bonding conductor is attached. This might include an electrical panel, a pathway, building steel, a cable tray or equipment such as a Local Area Network (LAN) switch. Typically this is the TIA-606-B identifier of the equipment. In this example, we add the grid location of the rack or cabinet to which the RGB is attached: 2A=RGB1/AJ05 2A = Floor 2, Room A RGB = Rack Grounding Busbar #1 AJ05 = Rack at grid location AJ05 which is the object attached to the RGB 10
11 BUILDING CABLING SUBSYSTEM 2 AND 3 CABLE IDENTIFIERS The backbone cabling is handled very similar to Cabling Subsystem 1 link identifiers explained earlier in this document. A typical identifier will include the identifier for the space at one end of the cable, the space terminating the other end of the cable and one or two alpha numeric characters to identify a single pair or port. 1A.AJ06-27:01 / 2A.AJ09-27:01 1A = Floor 1, Space A AJ06 = Rack or cabinet at grid location AJ06 27 = Patch panel located 27 rack units from the bottom of the frame :01 = Port 1 For Class 3 and 4 installations, the installer is just adding campus and building identifiers. Example of a backbone cable identifier: A-ENG-1A:AJ06-27:01-06 / B-ADM-1A.AJ09-27:01-06 A = Campus A ENG = Engineering Building B = Campus B ADM = Administration Building NOTE: Administration of Cabling Subsystem 2 and 3 identifiers is by pair groups or ports rather than copper pairs or single fibers. Each port or pair on a building Cabling Subsystem 2 and 3 cable shall have a unique identifier. Individual optical fibers and balanced pairs are typically color coded rather than individually marked. 11
12 FIRESTOPPING The TIA-606-B legacy format for marking a fire stop would be printed as follows: 2-FSL01(6) 2 = 2nd Floor -FSL = First Stop Location 01 = Location # (6) = 6 hour burn rating The comparable format for ISO/IEC would be printed as follows: SF02-2A/3A=U(3)=F SF02 = Building SF02 2A = Floor 2, space A / = Located between telecom rooms 2A and 3A 3A = Floor 3, space A =U = U following the equal sign specifies the element is a pathway (3) = Sleeve 3 F = Specified the element is a Fire stop location SPECIAL PURPOSE CABLE MANAGEMENT SOFTWARE The new ANSI/TIA-606-B standard also covers automated infrastructure management systems which may include technology used to detect and to record infrastructure changes (e.g. pre-printed serialized bar codes, human readable text, RFID chip technology and electrical continuity contacts. There are no specific labeling requirements and each can be labeled in a variety of ways that suit each installation, but should contain the records described in the 606-B. These specialized software programs should be able to directly generate the labels or be able to export data to other devices or labeling software that can generate the machine printed labels. Figure 5: Option C is using two MPO/MTP connectors stacked with 1 MPO/MTP connector on top of the other connector. This drawing shows Receiver on top and Transmitter on the bottom. 12
13 OUTSIDE PLANT AND PATHWAY IDENTIFIERS The new standard also addresses outside plant and pathways by identifying inter-building and outside plant pathways as well as entrance pathway identifiers. As an example, a maintenance hole, handholes, pedestal or outdoor cabinet might be identified as follows: LAX1-MH101( , ) The Maintenance Hole on campus LAX1 is located at Global Positioning System (GPS) coordinates The use of GPS is optional and could be replaced site locations such as site MH12 which would represent Maintenance Hole 12 on campus LAX1. See section 9 under Optional Identifiers For Infrastructure Elements. LAX1-MH12 Termination Type Color Pantone # Typical Application ALTERNATE LABEL FORMATS Demarcation Point Network Connection Common Equipment Cabling Subsystem 3 Cabling Subsystem 2 Campus Inter-building Cabling Orange Green Purple White Gray Brown 150C 353C 264C 422C 465C Central Office Connection User Side of Central Office Connection Connection to PBX, Mainframe Computer, LAN, Multiplexer Terminations of Building Cabling Subsystem 3 Cable Connecting MC ot ICs Termination of Building Cabling Subsystem 2 Cable Connecting IC ot HCs Termination of Campus Inter-building Cable Between Buildings Section 4.6 allows the use of a direct link to an identifier within the records using a printed label with a short and simple numeric code or a machine readable label such as an RFID chip or a pre-printed barcode label. So, as example, in the record, the identifier for a particular port might be: A-ENG-1A:AJ06-27:01-06 / B-ADM-1A. AJ09-27:01-06 The actual label might simply be printed with the number 132, (in human readable text or barcode) but the number 132 is a direct link and cross reference to the detailed identifier (A-ENG-1A:AJ06-27:01-06 / B-ADM-1A.AJ09-27:01-06) in the actual database. This can reduce the number of characters required to print on the cable or equipment label. Cabling Subsystem 31 Blue 291C Terminations of Cabling Subsystem 1 Cable In TSs COLORS Miscellaneous Yellow 101C Table 4 Colors Alarms, Security, or Energy Management Using colors is recommended, but not a requirement. Many smaller installers find it costly to stock and purchase many colors of labels in order to meet a requirement that might not fit their particular situation. The 606-B is not color dependent and allows the installer to fully identify without requiring the use of a color. If color is used, the installer should use the pantone color scheme as outlined in section , table 4. 13
14 RECORDS Most installers are aware of the cost of installing and maintaining an efficient and cost effective ITS. Labeling is crucial in this area. Yet, there is an aspect that is often neglected record keeping. Maintaining records of your ITS installation is the most valuable part of any labeled configuration. In the standard, you must link a record for each identifier that is printed on a label. If the records are complete and accurate and contain the recommended data as outlined in the labeling standard, the customer will have a well documented infrastructure that can be understood and managed by anyone responsible for making moves, adds or changes. So, the label is important, but if you do not attach the relevant data to that identifier, much of that value is lost. A database can be something as simple as an Excel spreadsheet. Each identifier makes up a row in the spreadsheet and each element associated with that identifier is recorded in the columns going across the database. As an example, each Cabling Subsystem 1 link (Horizontal link) record shall include the following: Example of spread-sheet implementation of class 1 administration system: horizontal link records sorted by building room number. Location of work area outlet connector Cabling Subsystem 1 link identifier. Outlet connector type (8 position, 110, SC or duplex as example) Cross connect hardware (Patch panel, T568B Cate 53, etc) Cable type (4pr. UTP, Cat 5e, plenum, or 2 strand 62.5/125 multi-mode, FDDI grade, riser) Cable length Service record of link It may also include any other data that the installer or customer feels is pertinent to the installation such a the color code of the outlet connectors, wiring scheme, Multiple User Telecommunications Outlet Assembly (MUTOA) Consolidation Point (CP) or Transition points. (It could be shown in the form of an Excel Spreadsheet like below) Horizontal Link Identifier Cable Type Building Location of Outlet Outlet Connector Type Color Code of Outlet Connector Other Outlet Connectors at this Location Wiring Scheme Horiz. Cable Length Service Record MUTOA CP Trans. Point 1A-W01 Cat 5e Plenum R111 8 Pos Mod Beige 1A-A01 1A-B01 568A 129ft Tested 4/22/01 No No No 1A-A01 Cat 5e Plenum R111 8 Pos Mod Orange 1A-W01 1A-B01 568A 127ft Tested 4/22/01 No No No 1A-B /125, Two Strand, Plenum R111 SC Duplex Blue 1A-W01 1A-A01 N/A 128ft Tested 5/23/01 No No No 1A-W02 Cat 5e Plenum R112 8 Pos Mod Beige 1A-A02 1A-B02 568A 112ft Tested 4/22/01 No No No 1A-A02 Cat 5e Plenum R112 8 Pos Mod Orange 1A-W02 1A-B02 568A 112ft Tested 4/22/01 No No No 1A-B /125, Two Strand, Plenum R112 SC Duplex Blue 1A-W02 1A-A02 N/A 113ft Tested 5/23/01 No No No 14
15 If the ITS is not efficient to administer, the cost of any mistakes far outweigh the initial cost of recording all the data initially at the time of installation. In the long run, the expense of not recording administration data can be very high. The outlay of testing and tracking cables can be expensive and can result in a backlog of cables that are abandoned in the plenum in lieu of simply pulling a new cable. Even an installation that appears intuitively simple, may grow over time and eventually become an unmanageable mess if the ITS is not recorded properly. The TIA-606-B standard is the culmination of years of work by many experts, installers, engineers and customers to make the best system possible. There are still elements that must be addressed, but it is a standard that is now having global attention. It is a paradigm that will continue to develop and change the way we think about administration and labeling. 15
16 About HellermannTyton HellermannTyton is a global manufacturer of identification, cable management and connectivity solutions for the commercial data, telecommunications, electrical, and industrial markets. HellermannTyton offers an integrated approach to design, operation, and delivery to optimize service and solutions for local and global customers. The company s engineered solutions and innovative products are designed and constructed to meet the strictest quality standards while delivering reliable implementation at the lowest cost. For more information, call HellermannTyton at or visit for published details. Author Todd Fries HellermannTyton North American Corporate Headquarters 7930 N. Faulkner Rd, PO Box Milwaukee, WI Phone: (414) , (800) Fax: (414) , (800) [email protected] TS16949, ISO 9001, and ISO14001 Certified This information contained in the document represents the current view of HellermannTyton with respect to the subject matter contained herein as of the date of the publication. HellermannTyton makes no commitment to keep the information presented up to date and the facts in this document are subject to change without notice. As HellermannTyton must respond to the changing market conditions, HellermannTyton cannot guarantee the accuracy of any information presented after the date of the issuance. This document is presented for informational purposes only. All rights reserved. No part of these pages, either text or image may be used for any purpose other than personal use. Therefore, reproduction, modification, storage in a retrieval system or retransmission, in any form or by any means, electronic, mechanical or otherwise, for reasons other than personal use, is strictly prohibited without prior written permission. Copyright 2011, All rights reserved. May not be reproduced without the consent of HellermannTyton. HellermannTyton Corporation 16
ANSI/TIA/EIA-606. Administration Standard for the Telecommunications Infrastructure of Commercial Buildings
ANSI/TIA/EIA-606 Administration Standard for the Telecommunications Infrastructure of Commercial Buildings Distributed by NDS INFORMATION- TELECOM SYSTEM --------------------------------------------- Head
Data Center Standards Making Progress on Many Fronts. Jonathan Jew J&M Consultants, Inc [email protected]
Data Center Standards Making Progress on Many Fronts Jonathan Jew J&M Consultants, Inc [email protected] J&M Consultants - 2008 Speaker Jonathan Jew Co-chair TIA TR-42.1.1 Data Center working group ANSI/TIA-942
Telecommunications Infrastructure Standard for Data Centers ANSI/TIA-942
Telecommunications Infrastructure Standard for Data Centers ANSI/TIA-942 Chris DiMinico [email protected] MC Communications Data Center Standards ANSI/TIA-942 Telecommunications Infrastructure Standard
ANSI/TIA-942 Telecommunications Infrastructure Standards for Data Centers
ANSI/TIA-942 Telecommunications Infrastructure Standards for Data Centers Jonathan Jew jew@j-and and-m.com J&M Consultants, Inc Co-chair TIA TR-42.1.1 data center committee Co-chair BICSI data centers
Telecommunications Infrastructure Standard for Data Centers. 802.3 Tutorial
Telecommunications Infrastructure Standard for Data Centers 802.3 Tutorial Prepared by: Jonathan Jew - J&M Consultants and Chris DiMinico - MC Communications - Co-chairs TR42.1.1 TR42: Data Center Standard
ANSI/TIA-942 Telecommunications Infrastructure Standard for Data Centers
ANSI/TIA-942 Telecommunications Infrastructure Standard for Data Centers Jonathan Jew [email protected] J&M Consultants, Inc Co-chair TIA TR-42.1.1 data center working group Co-chair BICSI data centers standards
Presenters Brett Weiss, Gabe Martinez, Brian Kroeger.
1 Presenters Brett Weiss, Gabe Martinez, Brian Kroeger. Topics to be covered: Cable identification Purpose of the various cable types Installation techniques Building Infrastructure Overview of networking
DIVISION 27 COMMUNICATIONS. A. System design shall be completed by a Registered Communications Distribution Designer (RCDD).
DIVISION 27 COMMUNICATIONS 27 00 00 COMMUNICATIONS A. System design shall be completed by a Registered Communications Distribution Designer (RCDD). B. Comply with American National Standards Institute
TIA-942 Data Centre Standards Overview WHITE PAPER
TIA-942 Data Centre Standards Overview WHITE PAPER TIA-942 Data Centre Standards Overview For the past 20 years, cabling standards have been the cornerstone of ensuring proper design, installation, and
A N S I/T I A/EIA 606A
A N S I/T I A/EIA 606A A D M I N IS T AT IO N S TA N DAD FO T E L E C O M M U N IC AT IO N S I N F A S T U C T U E QUICK EFEENCE G U I D E This guide is intended to be used as a reference to the application
Standards. www.nordx.com 5 ANSI/TIA/EIA-569-A (CSA T530)
The primary focus of this standard is to provide design specifications and guidance for all building facilities relating to telecommunications cabling systems and components. This standard identifies and
AMP NETCONNECT Data Center Cabling Solutions
AMP NETCONNECT Data Center Cabling Solutions Modern business and administrative environments require today more and more sophisticated IT services, what leads to an increasing demand for data provision
SECTION 25110 TELECOMMUNICATION ROOMS
PART 1 - GENERAL 1.1 SUMMARY A. SCOPE SECTION 25110 TELECOMMUNICATION ROOMS 1. This section includes the minimum installation requirements for equipment and cabling infrastructure in Telecommunication
Dat Da a t Cen t Cen er t St andar St d andar s d R o R undup o BICSI, TIA, CENELEC CENELE, ISO Steve Kepekci, RCDD
Data Center Standards Roundup BICSI, TIA, CENELEC, ISO Steve Kepekci, RCDD Introduction Regardless of business activity or size, all information technology (IT) groups have similar needs Provide secure,
InstaPATCH Cu Cabling Solutions for Data Centers
SYSTIMAX Solutions InstaPATCH Cu Cabling Solutions for Data Centers Design Guidelines August 2008 www.commscope.com Contents Overview 1 Instapatch Cu Solution Specification 2 Harness Assembly Design 3
ANSI/TIA/EIA-570. 570-A A Revisited. Residential Telecommunications Cabling Standard (Draft 6/22/99) Larry L. Hamlin, RCDD
BICS I CABLING INSTALLATION PROGRAM ANSI/TIA/EIA-570 Residential Telecommunications Cabling Standard (Draft 6/22/99) Larry L. Hamlin, RCDD Copyright BICSI, October 1999 -A Revisited 1.1 Purpose standardize
Network Design. Yiannos Mylonas
Network Design Yiannos Mylonas Physical Topologies There are two parts to the topology definition: the physical topology, which is the actual layout of the wire (media), and the logical topology, which
TIA 569 Standards Update Pathways & Spaces. Ignacio Diaz, RCDD April 25, 2012
TIA 569 Standards Update Pathways & Spaces Ignacio Diaz, RCDD April 25, 2012 The purpose of this Standard is to standardize specific pathway and space design and construction practices in support of telecommunications
TCTC Cabling Specifications
TCTC Cabling Specifications Purpose: To provide a standard specification that will be used for all Tri County Technical College (TCTC) facilities requiring structured cabling installation. Product specifications,
Innovation. Volition Network Solutions. Leading the way in Network Migration through Innovative Connectivity Solutions. 3M Telecommunications
3M Telecommunications Solutions for Networks Volition Network Solutions Leading the way in Network Migration through Innovative Connectivity Solutions Innovation The Broadband Migration Path 3M TM Volition
Structured Wiring Specifications ERAU Daytona Beach Campus (Dec 14 2011)
Structured Wiring Specifications ERAU Daytona Beach Campus (Dec 14 2011) A. Objectives The Information Technology (IT) Department of Embry-Riddle Aeronautical University (ERAU) seeks to establish a standards-based
ADC s Data Center Optical Distribution Frame: The Data Center s Main Cross-Connect WHITE PAPER
ADC s Data Center Optical Distribution Frame: The Data Center s Main Cross-Connect WHITE PAPER ADC s Data Center Optical Distribution Frame: The Data Center s Main Cross-Connect Introduction The primary
Structured Cabling Statement of Work
Structured Cabling Statement of Work Multiple Locations June 15, 2010 Page 1 A. GENERAL a. San Joaquin County (referred to as Owner ) is requesting proposals for a new structured cabling infrastructure
NUIG Campus Network - Structured Cabling System Standards Information s Solutions & Services (ISS)
NUIG Campus Network - Structured Cabling System Standards Information s Solutions & Services (ISS) Revision date 28 th January 2014 The purpose of this document is to assist Building Refurbishment and
DEPARTMENTAL REGULATION
U.S. DEPARTMENT OF AGRICULTURE WASHINGTON, D.C. 20250 DEPARTMENTAL REGULATION SUBJECT: Service Center Technology Modernization Project (SCTMP) Wiring/Cabling Specifications for Service Center Agencies
NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION 27 05 26 GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS
SECTION GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS RELATED SECTIONS: Section 27 00 00 General Requirements Section 27 02 00 Communication General Requirements Section 27 05 28 Pathways for Communications
Telecommunications Systems Narrative Page 1 The Engineering Enterprise
I. TELECOMMUNICATIONS GENERAL REQUIREMENTS A. The project consists of a renovation to the historic Clinical Sciences building, originally built in 1933. The existing building has a total area of 105,000
www.commscope.com Data Center Topology Guide
www.commscope.com Data Center Topology Guide Data Center Areas 1 Network Operations Center (NOC) The network operations center or NOC is the location where control of all data center networking, server
This presentation to be used in conjunction with:
1 This presentation to be used in conjunction with: Spec Sheets: SA-GRSP10, SA-GRSP09, SA-GRSP11 Samples in DC-GROUND-KIT 8/16/2012 2 Network Bonding and Grounding: TIA-607-B Generic Telecommunications
Migration Strategy for 40G and 100G Ethernet over Multimode Fiber
Introduction Migration Strategy for 0G and 00G Ethernet over Multimode Fiber There is a need for increased network bandwidth to meet the global IP traffic demand, which is growing at a rate of 0% per year
Running 1000BASE-T Gigabit Ethernet over Copper Cabling 30 March 1999 Colin Mick/The Mick Group with Bruce Tolley/3Com and Willem Wery/Intel
Running 1000BASE-T Gigabit Ethernet over Copper Cabling 30 March 1999 Colin Mick/The Mick Group with Bruce Tolley/3Com and Willem Wery/Intel Introduction When network managers decide on a cabling system,
2301.1 Scope: Communications and Electronic Systems addressed in this section include:
Chapter 23 COMMUNICATIONS / ELECTRONIC SYSTEMS SECTION 2301 - GENERAL 2301.1 Scope: Communications and Electronic Systems addressed in this section include: 1. Fire Alarm System 2. Telecommunication and
Security & Surveillance Cabling Systems
Security & Surveillance Cabling Systems Security and Surveillance Cabling Systems The video security industry is growing and ever-changing, offering a wealth of opportunity for today s security professionals.
Data Center Optimization: Component Choice. Innovative Design. Enabling Infrastructure
Data Center Optimization: Component Choice and Innovative Design Combine to Allow the Creation of an Enabling Infrastructure Data Center Spaces Data Center Spaces as Defined by the TIA 942 Standard Source:
UT Southwestern Medical Center Information Resources Cable Installation Standard
UT Southwestern Medical Center Information Resources Cable Installation Standard PART 1- GENERAL 1.01 SUMMARY A. Furnish and install wire, cable, devices, equipment, and accessories for a complete system
DESIGN GUIDELINES. Local Area Network
DESIGN GUIDELINES Local Area Network The total oversight and management responsibilities for information assurance (IA) and protection of DoDEA s critical infrastructure fall under the purview of the DoDEA
Data Centre & Enterprise Solutions. RapidNet
H E L L E R M A N N T Y T O N Data Centre & Enterprise Solutions RapidNet data centre & Enterprise solutions HellermannTyton is a leading global manufacturer of network cabling solutions which connect,
Minimum Standards for Data/Voice Infrastructure in New Building Construction
UNIVERSITY OF WATERLOO Minimum Standards for Data/Voice Infrastructure in New Building Construction 12/17/2012 Offices 1. Two Work Area Outlets (WAO) on opposite walls, each with 2 jacks 2. Each WAO shall
Structured and Point to Point Network Cabling for Industrial Automation
Structured and Point to Point Network Cabling for Industrial Automation Introduction Industrial automation systems are undergoing dramatic transformations that require businesses to adopt new strategies
DATA CENTER NETWORK INFRASTRUCTURE. Cable and Connectivity for the Most Demanding Networks. BerkTekLevitonTechnologies.com
DATA CENTER NETWORK INFRASTRUCTURE Cable and Connectivity for the Most Demanding Networks Customer-focused, technology-driven, quality-assured for an unparalleled RETURN ON infrastructure investment DATA
Maintaining Proper Polarity for Modular Pre-terminated Fiber Systems. Rudolph A. Montgelas Fiber Optic Senior Product Manager Ortronics/Legrand
Maintaining Proper Polarity for Modular Pre-terminated Fiber Systems Rudolph A Montgelas Fiber Optic Senior Product Manager Ortronics/Legrand November, 006 Introduction: Optical communication systems provide
270526-TC Grounding and Bonding for Telecommunications Systems
270526-TC Grounding and Bonding for Telecommunications Systems Part 1 - General Related Documents The following related sections of the OT standards shall also be applicable to this section. OT Engineer
Fiber Plant Design Considerations for Active DAS Mike Brownson VP DAS Technical Solutions Hutton Communications
Fiber Plant Design Considerations for Active DAS Mike Brownson VP DAS Technical Solutions Hutton Communications Topics! Understanding Fiber Types! Powering your Remotes via Composite Fiber! Fiber Design
SYSTIMAX SCS PowerSum and GigaSPEED XL Cabling Installation Guidelines
SYSTIMAX SCS PowerSum and GigaSPEED XL Cabling Installation Guidelines This document contains critical information regarding the installation of a certified SYSTIMAX SCS that meets or exceeds performance
Data Center Design Considerations
Data Center Design Considerations Chris DiMinico MC Communications [email protected] Contributors: Jonathan Jew, President, J&M Consultants (Telecommunication Engineering Firm) Co-chair TR42.1.1, Data
SECTION 27 13 24 COMMUNICATIONS OPTICAL FIBER OSP CABLING
SECTION 27 13 24 COMMUNICATIONS OPTICAL FIBER OSP CABLING PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete
Multiple Solutions for Connecting Multiple Dwelling Units (MDUs) WHITE PAPER
Multiple Solutions for Connecting Multiple Dwelling Units (MDUs) WHITE PAPER Multiple Solutions for Connecting Multiple Dwelling Units (MDUs) Abstract Fiber-to-the-Premises (FTTP) networks increasingly
Building Telecommunications Infrastructure Requirements
Building Telecommunications Infrastructure Requirements This page identifies specific requirements for the design of telecommunications infrastructure for buildings at Clemson University. (Revised October,
How To Write An Infrastructural Standard For Data Center Infrastructure
Infrastructure Standard for Data Centers ANSI/CSA/EIA/TIA-942 (PN-3-0092) Introduction When approved, the standard will be: ANSI/CSA/EIA/TIA-942 Telecommunications Infrastructure Standard for Data Centers
Data Center Design for 40/100G
Data Center Design for 40/100G With the continued requirement for expansion and scalability in the data center, infrastructures must provide reliability, manageability and flexibility. Deployment of an
Managing High-Density Fiber in the Data Center: Three Real-World Case Studies
Managing High-Density Fiber in the Data Center: Three Real-World Case Studies CHALLENGE In today s data center, fiber optic links have become more vital than ever for transmitting data to and from a large
What is a Datacenter?
What is a Datacenter? Telecom Room Primarily Cross Connect Equipment and switches. Computer room A room whose primary function is to house computer equipment. (Servers, Storage) 5 or less cabinets Small
Section 27 05 26 Grounding and Bonding for Communications
Part 1 General 1.1 General 1.1.1 Summary A. This section governs the products and execution requirements relating to furnishing and installing grounding and bonding for the communication systems. B. Description
ATTACHMENT F 050R6800016 - CABLE AND WIRING SERVICES FUNCTIONAL AREA I PRICE PROPOSAL FORM Amendment 6
050R6800016 CABLE AND WIRING SERVICES (Column A) (Column B) (Column C) (Column D) (Column E) (Column F) (Column G) (B+C+D+E)*F= G Item Description PER 100' RUN PER 150' RUN PER 200' RUN PER 300' RUN QUANTITY
Cabling Requirements for the District of Columbia on behalf of the Criminal Justice Coordinating Council
Cabling Requirements for the District of Columbia on behalf of the Criminal Justice Coordinating Council Date: 6/19/2013 Version: 1.0 Prepared by: Gregory Cotten Department of General Services District
CommScope Intelligent Building Infrastructure Solutions (IBIS)
SYSTIMAX Solutions CommScope Intelligent Building Infrastructure Solutions (IBIS) Questions & Answers Q. What is an Intelligent Building? A. An intelligent building can be defined as one which provides
Category 6 Solutions. 4. Category 6 Solutions. 09/08 400836IN TrueNet Structured Cabling. Introduction... 4.2. Cable... 4.3. Patch Panels... 4.
Category 6 Solutions Introduction... 4.2 Cable... 4.3 Patch Panels... 4.4 Modules... 4.6 Patch Cords... 4.12 Outlets... 4.16 Faceplates...4.18 4. 1 Search Category 6 Solutions Introduction ADC KRONE s
Implementing Fast Ethernet
Implementing Fast Ethernet R The Next Generation of Ethernet Fast Ethernet (also known as IEEE 802.3u or 100BASE-T) is quickly becoming the successor to Ethernet as the network topology of choice. Fast
Cat 5, 6 or 7? Standards. Background. A University Standard for Structured Wiring. Network Points Installed. British Standards.
Cat 5, 6 or 7? A University Standard for Structured Wiring. Background isolutions recently formed Incorporates all IT service providers within the University. Focus on all ICT needs of the user and the
ADC-APC Integrated Cisco Data Center Solutions
Advanced Infrastructure Solution for Cisco Data Center 3.0 Ordering Guide ADC-APC Integrated Cisco Data Center Solutions The evolution of data centers is happening before our eyes. This is due to the
Policy Title-Aquia Data Center Operational Policy & Procedure. Policy ID - TSD-ADC001. Version - Version: 1.0. Supersedes Version 1.
Policy Title-Aquia Data Center Operational Policy & Procedure Policy ID - TSD-ADC001 Version - Version: 1.0 Supersedes Version 1.0 Review Date One (1) year from effective date. Policy & Procedure - Provides
The Need for Low-Loss Multifiber Connectivity
WP_LowLoss_D_B 10/13/14 2:08 PM Page 2 The Need for Low-Loss Multifiber Connectivity In Today s Data Center Optical insertion loss budgets are now one of the top concerns among data center managers, especially
ANSI/TIA/EIA - 568-A, Commercial Building Telecommunications Cabling Standard.
WIRING STANDARD INTRODUCTION This standard defines a telecommunications wiring system for North Dakota State Agencies, offices or buildings that will support a multi-product environment. The purpose of
Data Center. Pre-terminated. Patch Panel System. Cabling Systems Simplified. Patch Panels. 10G + Gigabit. Patch Cords. Plug & Play Installation
Data Center Pre-terminated Patch Panel System Patch Panels Plug & Play Installation 10G + Gigabit Patch Cords Bundled + Labeled Cabling Systems Simplified Our Mission At Cablesys, our mission is to simplify
ADC KRONE s Data Centre Optical Distribution Frame: The Data Centre s Main Cross-Connect WHITE PAPER
ADC KRONE s Data Centre Optical Distribution Frame: The Data Centre s Main Cross-Connect WHITE PAPER ADC KRONE s Data Centre Optical Distribution Frame: The Data Centre s Main Cross-Connect Introduction
A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.
ENDURA NSM5200 SERIES NETWORK STORAGE MANAGER TECHNICAL SPECIFICATIONS SECURITY SYSTEM DIVISION 28 ELECTRONIC SAFETY AND SECURITY LEVEL 1_28 20 00 ELECTRONIC SURVEILLANCE LEVEL 2_28 23 00 VIDEO SURVEILLANCE
The Three Principles of Data Center Infrastructure Design WHITE PAPER
The Three Principles of Data Center Infrastructure Design WHITE PAPER The Three Principles of Data Center Infrastructure Design Understand These Three Principles and You ll: Lower your total cost of ownership
TELECOMMUNICATIONS STRUCTURED CABLING GUIDELINES AND SPECIFICATIONS. University of Chicago IT Services Infrastructure Services October 2011
TELECOMMUNICATIONS STRUCTURED CABLING GUIDELINES AND SPECIFICATIONS IT Services Infrastructure Services October 2011 Table of Contents 1 Introduction... 4 1.1 Planning and Design... 4 1.2.1 Roles and Responsibilities...
Design Guide. Universal Connectivity Grid. SYSTIMAX Solutions from CommScope
Design Guide Universal Connectivity Grid SYSTIMAX Solutions from CommScope CONTENTS Introduction 3 Commercial building network overview 4 Zone cabling 5 Universal Connectivity Grid 6 UCG cell size 7 Integrating
1. Furnish and install faceplate and modular jacks at each single gang outlet as described below:
Washington University in St. Louis Building: Communication Specification: Research Voice/Network/Typical 1. Furnish and install faceplate and modular jacks at each single gang outlet as described below:
Zone Distribution in the Data Center
Zone Distribution in the Data Center By Jennifer Cline, RCDD As data centers face the continued need to expand and grow, the fundamental concerns and needs remain constant. Key concerns of the data cabling
Data Center Network Infrastructure The Smart Choice For Your Data Center
Data Center Network Infrastructure The Smart Choice For Your Data Center Network Infrastructure Expertise Unrivaled Quality, Service, and Support Innovative Solutions Custom Products Strong Return on Infrastructure
Cabling and Building Infrastructure for Technology
Cabling and Building Infrastructure for Technology by: Ernest J. Schirmer, Director Information Technology Infrastructure Design CUH2A Architecture Engineering Planning 211 Carnegie Center Princeton, NJ
21 st Century Campus Network Responsibility Matrix 5/26/10
Definitions: DoIT Standards This column details the minimal configuration, which DoIT has defined in order to provide a campus-wide standard level of service. Departments may request services, which exceeds
FTE Cabling Best Practices Author: Todd Bill, RCDD/NTS
FTE Cabling Best Practices Author: Todd Bill, RCDD/NTS Document ID: WP-07-01-ENG Original Issue Date: May 2007 Version: 1.0 FTE Cabling Best Practices 1 Table of Contents Introduction and Applicable Standards...3
Design Guide. SYSTIMAX GigaSPEED X10D Solution Design and Installation Guidelines. June 2015
Design Guide SYSTIMAX GigaSPEED X10D Solution Design and Installation Guidelines June 2015 Contents Overview 1 Code Requirements and Power Separation 2 Bonding and Grounding 2 Administration and Labeling
1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications.
Issued 2005/06/01 Section 16743 Data System Page 1 of 7 PART 1 GENERAL 1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications..2 Data system equipment
Intelligent Cable Management Systems
Intelligent Cable Management Systems Bringing Practical Application Karen Pearson - Leviton Why Cable Management Matters Performance Cooling and air-handling Maintenance ANSI/TIA 569* Telecommunication
IT Cabling Solutions
IT Cabling Solutions Signamax & Hitachi Cable America System Performance Signamax & Hitachi Cable America (Hitachi) system quality assurance testing is based on the worst-case model - four-connector 100-meter
Network Topologies and Distances
Network Topologies and Distances Chris Di Minico MC Communications [email protected] 1 Presentation objectives Considerations for 802.3ba fiber link distance objectives 2 HSSG Objectives Support full-duplex
Terminating 25-Pair Cable and 4-Pair Cross Connects
Terminating 25-Pair Cable and 4-Pair Cross Connects Estimated Time: 90 minutes Number of Teams: 2 Number of Team Members: one to four This Lab has four major parts that will be addressed separately. 1.
Migration to 40/100G in the Data Center with OM3 and OM4 Optical Connectivity
Migration to 40/100G in the Data Center with OM3 and OM4 Optical Connectivity Needs in the Data Center With the continued requirement for expansion and growth in the data center, infrastructures must provide
FITNESS FACILITY WIRING SPECIFICATIONS. NETPULSE Inc. 2331 3rd Street San Francisco, CA 94107 Phone: 415.643.0223
FITNESS FACILITY WIRING SPECIFICATIONS NETPULSE Inc. 2331 3rd Street San Francisco, CA 94107 Phone: 415.643.0223 CONTENTS: - Scope of work Summary - Equipment list - Technical specifications - Map of data
Data Center Solutions Guide. Solutions to Support, Protect, Enclose and Connect Data Center Equipment and Infrastructure
Data Center Solutions Guide Solutions to Support, Protect, Enclose and Connect Data Center Equipment and Infrastructure Data Center Solutions Overview Cooper B-Line is your one-stop resource for support
Table of Contents. Fiber Trunking 2. Copper Trunking 5. H-Series Enclosures 6. H-Series Mods/Adapter Panels 7. RSD Enclosures 8
Data Center Guide 1 Our Philosophy As a leader in the enterprise cable industry since our inception over three decades ago, we can help you implement the solution that will work best for your cabling infrastructure,
Part 1: General Requirements TELECOMMUNICATIONS INDUSTRY ASSOCIATION
TIA/EIA STANDARD ANSI/TIA/EIA-568-B.1-2001 Approved: April 12, 2001 TIA/EIA-568-B.1 Commercial Building Telecommunications Cabling Standard Part 1: General Requirements TIA/EIA-568-B.1 (Revision of TIA/EIA-568-A)
InstaPATCH ZERO Solution Guide
SYSTIMAX Solutions InstaPATCH ZERO Solution Guide Rapid Server Deployment and Change Management North, South and Central Americas 1 As data centers face ever-increasing IT demands, growth demands and evolving
Corning Cable Systems Optical Cabling Solutions for Brocade
Corning Cable Systems Optical Cabling Solutions for Brocade Building high-density, high-port-count, structured cabling solutions to scale storage area networks to thousands of ports Contents Executive
IT&T Infrastructure Standards
Technology Services IT&T Infrastructure Standards Version 1.5 17 th April 2015 Page 1 Table of contents 1 CHANGE HISTORY... 3 1.1 DOCUMENT HISTORY... 3 1.2 REVIEWERS... 3 1.3 APPROVALS... 3 2 INTRODUCTION...
Things You Must Know About Gigabit Ethernet 1. Understanding Gigabit Ethernet
Things You Must Know About Gigabit Ethernet 1. Understanding Gigabit Ethernet Today s network managers know that modern demands on a network by its users can shrink bandwidth dramatically. Faster computers,
The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects
The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects White Paper /7/0 Executive Summary Now that the TIA/EIA-568-B.- Category 6 Copper Cabling
The Optical Fiber Ribbon Solution for the 10G to 40/100G Migration
The Optical Fiber Ribbon Solution for the 10G to 40/100G Migration Bill Charuk, SR Product Manager, Data Center Solutions Introduction With the advent of data centers in communication infrastructure, various
Rack & Stack 123 TM. Enterprise Education Government Telecommunications Service Providers Tel: 408-586-8800
Rack & Stack 123 TM Enterprise Education Government Telecommunications Service Providers Tel: 408-586-8800 Rack & Stack 123 TM Introduction Simplicity Scope of Work Rack & Stack 123 TM Benefits 2 toll-free:
ABOUT ANIXTER UNIVERSITY
Q3 2015 ABOUT ANIXTER UNIVERSITY Anixter University TM is the educational initiative of Anixter, a leading global supplier of communications and security products, electrical and electronic wire and cable,
C6 A modul and C6 A modul K. The new connection system for all applications of course with Cat.6 A
C6 A modul and C6 A modul K The new connection system for all applications of course with Cat.6 A Intelligent solution for structured cabling systems There is an enormous need for high data transfer rates
ADC Structured Cabling Solutions
ADC Structured Cabling Solutions The highest performing cross-connect system in the world HighBand Wall Mount Patching Solution Reliable, secure and cost effective ADC s HighBand cross connect solution
Trends and Standards in LAN Cabling Systems Intelligent Buildings
Trends and Standards in LAN Cabling Systems Intelligent Buildings A Sitaramaiah Managing Director CommScope Solutions India Intelligent Buildings Smart Cities Opportunities in Systems Integration Smart