Fire Safety Management Strategy
|
|
|
- Meghan Lindsey Clark
- 9 years ago
- Views:
Transcription
1 Fire Safety Management Strategy Introduction This strategy is a plan and method of approach to how Medway Council Housing Services (the council) will both continue to meet our statutory obligations under the Regulatory Reform (Fire Safety) Order 2005 (FRO) which is for communal areas and Housing Act (2004) for internal areas within flats and how we plan to address areas that are identified from Fire Risk Assessments (FRA) and other guidelines. The Housing Act 2004 The Housing Act 2004 makes requirements regarding the condition of a broad spectrum of homes, including individual flats within a block and the common parts of that block. Assessment of the conditions within flats or the common areas is carried out by means of the Housing Health and Safety Rating System ( HHSRS ) specified in the Act. This is to provide a means of identifying hazards and whether the consequent risk to people is acceptable. A total of 29 hazards, including the hazard of fire (hazard 24), must be considered in carrying out the HHSRS. To comply with the Housing Act, an assessment is carried out on each individual flat, rather than the entire block as a single building in order to identify any Category 1 (greater) or Category 2 (lesser) hazards. Further information of how we comply with this legislation is detailed under internal. The Regulatory Reform (Fire Safety) Order 2005 The principal fire safety legislation in England and Wales is the Regulatory Reform (Fire Safety) Order 2005, which revoked or repealed all, or parts of, over 100 earlier items of legislation and thus reformed the earlier, very fragmented legal framework for fire safety. The Regulatory Reform (Fire Safety) Order 2005 requires a responsible person to be identified. The Responsible Person is defined as the employer, if the workplace is to any extent under his control. The main role of this person is to ensure that a suitable and sufficient fire risk assessment is carried out. The common law principle of everyman s home being his castle applies to council properties as to all other dwellings. Thus potential fire hazards within 1
2 the confine of the individual home and the combustible materials there are not subject to fire safety legislation. Although the Regulatory Reform Order does not apply within individual homes (despite our good practice of undertaking FRAs when a property becomes void) it does apply to the common areas of blocks of flats and homes for independent living schemes which is addressed further under External and Homes for Independent Living Schemes. The purpose of this strategy is to ensure that we have reasonably covered all risks identified from FRA s. It must be recognised that it will not always be realistic nor risk proportionate to impose solutions from the current guidance retrospectively to existing buildings. For example where it occurs for the requirement of elements to be brought up to standard, following consultation, instead material improvements will be made to existing elements. Therefore this strategy has been produced to balance the need to prioritise the most critical risks within a budget that the HRA business plan allows. The council has identified and prioritised works for the highest rising blocks with a high concentration of flats. Current guidance has been used to set aspirational benchmarks against which to assess the adequacy of fire protection within existing blocks of flats, with an action plan on how we plan to achieve compliance with the councils benchmark standard for flats and common parts. Objectives The objectives of this strategy are to: Ensure suitable resources are in place to prevent the cause and spread of fire and if/when they occur to minimise their impact within communal areas and individual properties Place primary importance on the life, safety and welfare of our residents and staff Following a FRA to have in place the effective planning, organisation, control, monitoring and review of the preventative and protective measures Protect the councils assets from the spread of fire and interruption of business Fulfill our legislative duties as landlord and responsible person Context As of April 2015 the council manages 3004 properties which includes 286 Homes for Independent Living units and 200 leaseholder properties. Most of 2
3 the buildings in the councils portfolio would be regarded as being low rise, that is to say of no more than three floors in height. Prior to February 2015 all of the council s stock was built to standards that predate current Building Regulations. The profile of stock by dwelling type (built form) is: Property Type Total Bungalow 227 Flat/Bedsit 1204 House 1287 HfIL 286 Grand Total 3004 The bedroom composition of the stock is: The age profile of the stock is: No Bedrooms Total 1 Bed Bed Bed Bed 28 5 Bed 1 Grand Total 3004 Age Description Total Pre to to to to present 852 Grand Total 3004 In 2013 we consulted South Thames Gateway (STG), providers of the Councils joint venture Building Control Partnership to undertake Fire Risk Assessments (FRA) amongst our stock. Since these FRA s we have progressed with a number of works and initiatives. Where applicable and prioritised, properties have benefitted from the following initiatives: The council maintains a record of 100% annual gas servicing and offers this service to leaseholders at a rechargeable cost. 3
4 The use of supplementary heating (portable heaters) and electric blankets by residents is minimised by the provision of effective central heating systems in all of our properties. Replaced existing automatic opening vents to communal stairwells Installed dry risers to communal blocks where necessary Installed additional emergency lighting to communal areas Secured bin areas and improved waste management Increased fire signage to communal areas Replaced or upgraded UPVC windows where appropriate on escape routes Increased compartmentation by protecting external airbricks Replaced communal area meter boxes with fire protected and insulated types Increased fire protection of bin chutes and fitted dampners to chutes Replaced storage doors with minimum FD30 doors Upgraded fire seals to doors Replaced infill panels to common areas with fireproofed altrernative Replaced riser shaft doors A programme has been in place to ensure that all dwellings have a working smoke detector in the circulation areas, hardwired into the electrical supply with a battery back-up by With further improvements now underway to interlink detectors. Currently all properties have an electrical periodic certificate that is less than 5 years old. A programme of periodic testing is still in place and we have commenced a re-wire programme. Front doors to flats where there is an impact on means of escape are in the process of being replaced with those that meet current standards, in those properties where the risk is deemed to be highest Introduced a zero tolerance policy and procedure for the management of fire risks in common areas 4
5 The Council has designed, tested and constructed discreet fire resistant riser covers that can be retro fitted to vertical risers, bin chute covers and electric meter cupboards Financed a budget of 4.3 million specifically for works identified from FRAs from 2013/16 (Appendix A) Embarked on an estate inspection schedule throughout the year where we inspect communal areas of estates where there are 10 or more properties Revised our Void Standard to include consideration for means of escpae, fire protection in the kitchen to include a kitchen fire door All visiting staff have undertaken HHSRS training that includes an awareness of the hazard of fire Continued a programme of stock condition surveys aiming to undertake one full survey in each property every five years STG have been commissioned by the council to undertake and review FRA s that evaluate the risk of fire and safety to people within common parts; and recommended a program of works to mitigate risks identified Aims The strategy is broken down into three separate aspirational standards/benchmarks. Common Areas HFIL Schemes Internals Benchmarks should be used to assess the standard of fire protection in a block of flats. They are not prescriptive, and the aim should be to use them to determine a reasonable approach to improving fire safety where the fire protection measures have been found to be inadequate, as detailed in the action plan that follows. Common Areas Our common area standard has incorporated works identified from FRA s and meets the general principles of these that include: Measures to reduce the risk of fire and the risk of spread of fire Means of escape from fire 5
6 Measures to ensure that escape routes can be safely and effectively used An emergency plan, including procedures for residents in the event of fire Measures to mitigate the effects of fire External facades External facades should not provide potential for extensive fire spread. When assessing blocks of flats, particular attention should be given to any rain screen or other external cladding system that has been applied and to facades that have been replaced. The use of combustible cladding materials and extensive cavities can present a risk, particularly in high-rise blocks. Restrictions are normally applied to the nature of such materials and in particular their surface spread of flame characteristics. Cavity barriers are also required in some circumstances. Smoke control Measures should be taken to provide and ensure that escape routes remain free from smoke such as vents or windows in internal communal areas. Electrical installations Fixed electrical installations will be subject to periodic testing and test every five years in the case of the common parts. Surface finishes The surface finishes of walls and ceilings in escape routes can affect the rate of fire spread and contribute to the development of a fire and their suitability will be reviewed. Corridors and stairwells Corridors leading to and including stairways need to be enclosed in fire resisting construction with fire resisting, self closing doors. Any external stairways need to be suitably separated from the building by fire resisting construction and doors. Any areas, rooms or risers opening onto communal escape corridors and stairways need to be fitted with fire resisting doors that are self closing or kept locked shut. Additional protection is needed where there is only a single stairway for normal access and for egress in an emergency, normally comprising lobby approach and permanent openings or automatically opening vents for clearing smoke. 6
7 We will enforce a zero tolerance for items stored in communal areas. Heating and ventilation Heating and ventilation systems should be maintained regularly; particularly where they serve the common parts or are common to more than one flat. Emergency lighting There should be adequate illumination of escape routes to be able to see the way out in an emergency. With the possible exception of small two storey blocks of flats, with good borrowed light, for example, street lighting, blocks of flats should be provided with emergency escape lighting. Adequate artificial lighting and, where necessary, emergency escape lighting should be provided in common escape routes, such as corridors, lobbies and stairways, to enable residents and visitors to make their way safely out of the building (not necessary for small blocks of no more than two storeys). The lighting should be tested every month for its functionality and undertake a full discharge test once a year. Any lighting protection systems should be subject to regular maintenance. Signage Fire exit signs will be displayed to assist in the use of an escape route with which people are unfamiliar. We will not displace signs in a single stairway building, as it is not usually considered necessary to signpost the route that residents normally use to gain access to their flats. No smoking signs are a statutory obligation and will be put in place and replaced where identified as missing. Refuse/chutes Refuse bins and chutes should be enclosed in fire resisting construction and have permanent ventilation direct to open air. An automatic fire-resisting shutter should be fitted at the base of the refuse chute to restrict the spread of fire and smoke from a fire in the bin room. The provision of refuse chutes in low-rise buildings may also allow a rapid vertical spread of fire. Bin rooms will be fitted with smoke detection and dampeners to quickly suppress a fire within the refuse present. Smoke detectors will be fitted to the head of the refuse chute with a fire suppression device to reduce the risk of fire spread. In addition, the refuse chute hoppers will be fire resisting and fit correctly with a good seal in the chute aperture. Compartmentation 7
8 Obvious openings between floors, and in walls between flats and other ancillary accommodation (e.g. plant rooms) and the common parts, should be considered. Particular attention should be paid to service ducts or risers and any common ventilation systems. Security Access control linked to entry phones in flats Effective lighting Areas free from combustible material Communal Facilities Communal facilities include common rooms that may be used by all or a group of tenants. Examples include lounges, kitchen facilities and laundries. Where such facilities are not required they will be removed in consultation with the tenants / leaseholders of the building. Communal facilities will be inspected with a frequency proportionate with risks identified in the Fire Risk Assessment. Front and hallway doors Under current benchmark design guidance, doors forming part of the protected entrance halls and stairways within flats are normally specified as 20 minute fire resisting doors. Similarly, doors forming part of the protected escape route from the flat entrance door to the final exit, including the flat entrance door itself, are normally specified as 30 minute fire resisting doors with smoke seals Self closing doors fire resisting flat entrance doors, and doors provided to protect common coridoors, lobbies and stairways, should be fitted with suitable positive action self closing devices. The self closing device should be capable of closing the door in its frame from any angle and overcoming the resistance of any latch. The fitting of suitable self closing devices whether to replace rising butt hinges or because the doors are not fitted with self closing devices must be undertaken in the short term as a matter of priority. Dry risers Where identified via the fire risk assessment we will fit dry risers and maintain buildings that exceed the trigger distance. HfIL Schemes Mobility Scooters The use of mobility scooters is increasing and with it a requirement for space to store them. Normally, it would be expected that a tenant would store their 8
9 mobility scooter within their property. Some existing tenants may be permitted to store a maximum of one mobility scooter within common parts under the following conditions: 1. It does not obstruct the main thoroughfare, 2. All flammable articles and substances (including oxygen) are removed, 3. Charging is not undertaken whilst in the communal area unless specific provision is supplied by the Council. Where it has been identified as feasible some schemes have dedicated external storage through recent works. Communal hallway doors Where upgrades are being undertaken, consideration for individual needs is given to disabled residents who find it difficult to negotiate self-closing fire doors during everyday use of the building. The fitting of hold open devices, particularly on doors within the horizontal circulation spaces and in communal areas, should be considered. Communal facilities Communal facilities in schemes such as kitchens, lounges, laundry rooms and any plant or service room should, where necessary, be separated from common escape routes including corridors and stairways. They should have 30 minute fire resisting partitions and fire resisting doors. High hazard rooms should be separated from stairways by a protected a lobby. To reduce accidents while cooking in communal kitchens, the council ensures that all kitchens meet with appropriate standards and that there are no Category 1 hazards as set out in the Housing Health and Safety Rating System. Assessments Limitations of the residents should be taken into account when undertaking assessments in sheltered schemes, and any particular concerns resulting from the vulnerability of any residents should be addressed. Means of escape Adequate means of escape should be provided from communal areas, such as a lounge, which, ideally, should have one exit leading direct to open air. Furnishings Any furniture or soft furnishings provided in the common parts should be subject to a risk assessment and marked tagged with, Carelessness causes fire Fire safety systems and equipment 9
10 Putting in place programmes for routine inspection, testing, servicing and maintenance of fire safety systems and equipment. Fire alarm systems in place. Emergency plans will be clearly defined. A residents needs for support are usually assessed when they take up occupation, and this should include their ability to escape unaided in a fire, should then be reviewed as a matter of course as a persons circumstances change. Will store a premises emergency information box that contains information on the layout of the building and details of the residents for the fire and rescue service. Internal This aspirational standard is based on reviewing stock condition surveys which include FRA works, when a propery is either void or having planned maintenance works undertaken. Kitchens As the kitchen is a significant source of ignition, the Council will work towards installing 30-minute fire resisting doors to kitchens in low-rise buildings. Whilst this is above the standard required of existing doors, whenever a kitchen door requires repair works, the door, frame and furniture will be enhanced to ensure 30-minute resistance. All kitchens in General Dwellings, where practicable, are to be enclosed with suitable walls and door. Any proposed alteration must be approved by the Council in writing. Any application that reduces the fire integrity of means of escape or critical fire resisting barriers will be denied. If unauthorised works are carried out, the tenant will be expected to return the structure to its original state or will be re-charged to make it so. In order to reduce the potential for fire-spread between flats would be to first fully assess the line of ducts and their location before undertaking remedial works. Works would be designed to prevent the spread of flames and hot gases. This is a reasonable approach for bathrooms, but is less satisfactory for kitchens, where there is the potential for a serious fire in the room in which the vent is located. In these cases, the ideal solution would be to rearrange the ventilation to discharge directly to outside and not via a common duct. Depending on access, should be tested once every two years for those operated by fusible links. For those that are spring operated, this should take place every year. Common kitchen or bathroom extraction ducts will be suitably protected to ensure the spread of fire via these ducts is minimised. This may take the form 10
11 of fire resisting baffles within the duct or intumescent grilles fitted to extraction fans. Smoke Alarms Smoke alarms will be fitted and hardwired in a suitable place in every property. This will normally be the hallway. Where additional risks are identified, additional linked smoke alarms should be fitted to mitigate this risk. Smoke alarms in flats flats with more than one level and those with more than one hallway or circulation space will always require more than one smoke alarm. Each flat should have a minimum of a Grade D category LD3 system with smoke alarms in the circulation space or entrance hall. Gas Gas appliances will be serviced and inspected annually. A landlord safety certificate will be obtained for every property. See also Gas Safety Policy and Tenancy Agreement. Electricity Void properties will not be let unless an electrical safety certificate is provided. This will ensure the distribution box and circuits are all up to the minimum standard required at the time of rental. In addition, all redundant wiring will be removed wherever reasonably possible. All properties will have an electrical test undertaken every five years. Lofts Where properties form part of a line of joined properties, such as a terrace, the lofts are to be compartmented. Where compartmentation is not present, this will be introduced within a timescale based on risk. Where compartmentation is required in a loft adjoining a leaseholder or owner-occupier, the Council will progress the required works in negotiation with the leaseholder and/or owner-occupier. Fire Doors Individual flat front doors provide a key line of defense in fire safety and tenants and leaseholders are not permitted to change the front door to their flat without written permission from the Council. In order to ensure that this door remains fire resisting, any permission will insist that replacement of front doors, frames and door furniture are to be a minimum of 30 minutes fire resisting with intumescent strips and cold smoke seals. 11
12 Tenants or leaseholders who replace their front door with a door below this standard will have to upgrade to the FD30S standard as a minimum or will be recharged for works carried out to achieve this standard. Compartmentation Ensure that fire protection in an existing block maintains or improves the standard of compartmentation in order to sustain the stay put policy by protecting escape routes. The minimal levels of fire resistence for compartment walls and floors for existing blocks of flats should be (for three storey flats) 30 minutes fire resistence typically with timber floors with lath and plaster ceilings. Where this cannot be achieved, we should improve the means of escape, provide automatic fire detection and alarm systems. Walls between flats and common parts need to be compartment walls and, as such, will provide the necessary fire resistance. Fire resisting enclosure of flats is maintained at all openings e.g. flat entrance doors, internal windows into the access corridor, opening in walls and floors, vents and share extract ducts and doorways or hatches Means of escape A fire anywhere within a flat should not prevent the occupants of that flat from escaping unaided to an exit from the flat. Flat entrance doors should, where possible, be fitted with a suitable lock that can only be locked on the outside by use of a key operated deadlock, but than can still be opened from the inside by a handle or level without the use of a key. Significant changes Tenants and leaseholders have a duty to request written permission from the Council before commencing any significant changes to their flat. This will be refused if the fire integrity of the property is likely to be adversely affected. Tenants and leaseholders are required to re-instate any alterations that have not been approved in writing by the Council. If they fail to do this within a reasonable time, the Council will carry out the works and charge the tenant or leaseholder for the work. Where there is a significant change in use of the building or part of the building, Kent Fire Service are to be notified by the Head of Housing Management and the risk assessment is to be revised without undue delay. Where a flat is significantly redesigned by the Council, fire modeling should be carried out by a competent person to identify any additional fire risk introduced as part of the redesign. 12
13 General Leaseholders We will have the responsibility for maintenance of the flat entrance doors. The council will undertake a section 20-consultation process to undertake the works on the leaseholders behalf and enforcing works where access is prevented. Under these circumstances, the residents might be regarded as other persons having control of premises (as defined by Article 5(3) of the FSO, with a duty to ensure the adequacy of the flat entrance doors. However, use of powers under the Housing Act may be more appropriate and better defined route to achieving compliance with the FSO. In new leases, ideally the freeholder should retain control over all flat entrance doors. Stay Put Generally all accommodation is sufficiently compartmentised that a stay put policy is the norm. Residents would only evacuate in the event of an incident, if asked to by the emergency services or they are directly threatened. Communication We communicate vital messages including; how to prevent fires in the home and common parts; keep block secure; not store specific items; action to take in event of fire; stay put policy; how to safeguard communal routes; don t change flat; test smoke alarm; report essential repairs, explain relevant parts of tenancy agreement including allowing access for gas safety checks Fire Fighting Equipment Fire fighting equipment will not generally be installed for the use by residents however fire blankets will be provided for flatted developments. Records A fire record will be held for each HFIL and for others as considered necessary under the Regulatory Reform (Fire Safety) Order A fire record will be held for each low-rise building. This will detail: Risk Assessment Inspections Alarm maintenance and servicing (where appropriate) Emergency lighting tests/automatic opening vent testing Visits from a fire officer 13
14 Special Requirements For residents who have special requirements these will be identified at the sign up and addressed accordingly. This includes, for example, the installation of flashing smoke alarms for those with hearing impairments. Garages License agreement restricts the storage of items to vehicles only. Action Plan This financial year (2014/15) we have committed an estimated spend of 1,000,000. The commitment to ongoing spend on FRA works from 2015/16 is 1,000,000, 750,000 in 2016/17 and 500,000 in 2017/18. The action plan in Appendix B details how we intend to meet the objectives set within this strategy and our aspirational standards. 14
Fire precautions in dwellings. Private sector housing Providing homes building communities
Fire precautions in dwellings Private sector housing Providing homes building communities Version 3 Published by Norwich City Council August 2011 Contents Page Introduction 1 2 Types of dwellings (A) Shared
Guidance on loft conversions in two-storey houses
Guidance on loft conversions in two-storey houses Technical guidance for building control surveyors, designers and installers 01 Guidance on loft conversions in two-storey houses Technical guidance for
Fire Safety Policy. Fire Safety Policy: May 2011 Page 1 of 6. Version 1. Scope:
Version 1 Fire Safety Policy Scope: Effective Date: Review Date: Signed Off by: Author: Policy Owned by: This policy applies to Hackney Homes Ltd working on behalf of the London Borough of Hackney July
For use by landlords of small premises Premises Address
fire risk assessment For use by landlords of small premises Premises Address FIRE RISK ASSESSMENT for use by landlords of small premises Person having control of the premises: Name of landlord (if different):
RESIDENTS FIRE SAFETY INFORMATION PACK
RESIDENTS FIRE SAFETY INFORMATION PACK MARIE CURIE SCEAUX GARDENS ESTATE LONDON SE5 THE CONTENTS OF YOUR PACK Section Page No. 1. 3. Introduction Here we will explain the purpose of the Fire Safety Information
RESIDENTS FIRE SAFETY INFORMATION PACK
RESIDENTS FIRE SAFETY INFORMATION PACK CASTLEMEAD CAMBERWELL ROAD LONDON SE5 THE CONTENTS OF YOUR PACK Section Page No. 1. 3. Introduction Here we will explain the purpose of the Fire Safety Information
Building Control Guidance Note
Issued 01/01/13 Rev Page 1 of 5 If you intend to convert an existing loft space into additional rooms you will need to apply for Building Regulation Approval. You may also need Planning Permission if you
SPECIFIC GUIDANCE FOR A HOUSE IN MULTIPLE OCCUPATION (HMO) CONVERTED ENTIRELY INTO SELF CONTAINED FLATS
Document F SPECIFIC GUIDANCE FOR A HOUSE IN MULTIPLE OCCUPATION (HMO) CONVERTED ENTIRELY INTO SELF CONTAINED FLATS This document is intended as a specific guide for persons who own, manage or control Houses
Additional Guidance. for application to. HM Government Guide to Fire Safety Risk Assessment Residential Care Premises
Additional Guidance for application to HM Government Guide to Fire Safety Risk Assessment Residential Care Premises Good Practice Guidance 2016 Additional Guidance agreed between the National Association
Action required (Please tick) If you answered YES, record Action Points at STEP 4
RECORD OF FIRE SAFETY RISK ASSESSMENT Building Name & Use: Address: Postcode: Name of person(s) with fire safety duties: Name and contact details of assessor: Date of Assessment: 6 th February 2011 Laurel
For use by landlords of small premises Premises Address
fire risk assessment For use by landlords of small premises Premises Address FIRE RISK ASSESSMENT for use by landlords of small premises Person having control of the premises: Name of landlord (if different):
Fire Safety Risk Assessment Checklist for Residential Care Premises
Checklist for Residential Care Premises Name of Premises: Address of Premises: Name of Responsible Person: What area / location does the assessment cover? Does the assessment cover the whole site YES or
FIRE SAFETY RISK ASSESSMENT
FIRE SAFETY RISK ASSESSMENT For small single occupancy premises Premises Hertco Ltd ACME House, Old London Road, Hertford SG17 7LD Fire Safety Risk Assessment for Small Premises Introduction Regulatory
Fire safety advice for landlords
YOU CAN PREVENT IT Fire safety advice for landlords Introduction Each year there are over 50,000 fires in dwellings in the UK. These result in around 300 hundred fatalities and several thousand serious
RESIDENTS FIRE SAFETY INFORMATION PACK
RESIDENTS FIRE SAFETY INFORMATION PACK PERRONET HOUSE PRINCESS STREET LONDON SE1 THE CONTENTS OF YOUR PACK Section Page No. 1. 3. Introduction Here we will explain the purpose of the Fire Safety Information
London Borough of Barnet. Fire Safety in Houses in Multiple Occupation. A Guide to Landlords
London Borough of Barnet Fire Safety in Houses in Multiple Occupation A Guide to Landlords March 2016 Contents Introduction p.3 Summary of main requirements p.3 Fire Safety Precautions p.4 Protecting the
How To Write A Fire Risk Assessment
Fire Safety Risk Assessment This form is to aid you in carrying out a fire safety risk assessment of a property. The form is separated in to two parts: Part 1 initial assessment form and guidance notes
1.0 APPOINTMENTS 2.0 FIRE RISK ASSESSMENTS
Fire Risk assessment 1.0 APPOINTMENTS 1.1 Responsible Person. In compliance with the Regulatory Reform (Fire Safety) Order 2005 (FSO) the School s Head, Mrs J M Miles is appointed as the Responsible Person
FIRE RISK ASSESSMENT
REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT This template has been provided to assist the Responsible Person with the preparation of a Fire Risk Assessment and is not intended for commercial
Fire Risk Assessment Safety Checklist
Fire Risk Assessment Safety Checklist This checklist has been prepared to help you comply with The Regulatory Reform Fire Safety Order 2005 What is the Regulatory Reform (Fire Safety) Order 2005? The Regulatory
Fire Risk Assessment For Simple Premises
Fire Risk Assessment For Simple Premises Responsible Person (Employer or other person having control of the relevant premises) Company / Premises Name Address of Premises Postcode Primary Use of Premises
FIRE DETECTION AND ALARM SYSTEMS
HMO Information Sheet No 1 FIRE DETECTION AND ALARM SYSTEMS 1. Introduction When a property is in multiple occupation, the risk of fire breaking out is greater than in an ordinary single family home. Some
Contents. 1. Introduction 1.1 Reason for this Guide 3 1.2 Interpretation 1.3 Principles of Fire Safety 1.4 Legal Provisions 4
Contents 1. Introduction 1.1 Reason for this Guide 3 1.2 Interpretation 1.3 Principles of Fire Safety 1.4 Legal Provisions 4 2. Scope and Application 2.1 Scope of the Guide 5 2.2 Premises to which the
Guide For Owners, Agents and Managers of HMOs
Guide to Fire Safety in Houses in Multiple Occupation This guide outlines the fire safety provisions recommended for HMOs in Hertfordshire and is based upon the national guidance produced by LACORS. Guide
Building Control. Householder Guidance Leaflet No. 29. Fire detection in dwellings
Building Control Householder Guidance Leaflet No. 29 Fire detection in dwellings This leaflet is one of a series produced by the Hertfordshire Building Control Technical Forum GUIDANCE NOTE FOR HOME OWNERS
Property Accreditation Standards 2014/2015
Property Accreditation Standards 2014/2015 Promoting responsible renting of student housing in the city of Southampton Letting period 1st July 2014 to 30th June 2015 Version 1, 10/12/2013 All properties
UCL FIRE RISK ASSESSMENT POLICY& ARRANGEMENTS
Fire Safety Technical Guide UCL FIRE RISK ASSESSMENT POLICY& ARRANGEMENTS 1.0. BACKGROUND 1.1. The Regulatory Reform (Fire Safety) Order (known Fire Safety Order) applies to England and Wales (Northern
FIRE RISK ASSESSMENT
The Regulatory Reform (Fire Safety) Order 2005 FIRE RISK ASSESSMENT Employer or other responsible person Name of Premises Address Post Code Telephone N o Name of Assessor(s) Date of Assessment Date of
Northern Ireland Housing Executive: HMO Fire Safety Guide
Northern Ireland Housing Executive: HMO Fire Safety Guide Contents Equality Statement 5 Houses in Multiple Occupation (HMOs) means of escape in case of fire and other fire precautions 6 1.0 Introduction
Fire Safety Challenges and Solutions. Claire Guise Health and Safety Manager
Fire Safety Challenges and Solutions Claire Guise Health and Safety Manager Marie Curie Cancer Care (UK Wide) 9 Palliative Care Hospices (owned) Facilities Manager in place (NEBOSH General Certificate
- 5 - Table1. Maximum Compartment Volumes
- 5 - Part II - SPECIFIC REQUIREMENTS 5. Compartmentation 5.1 Every building should be divided into compartments by walls and floors to inhibit the spread of fire. 5.2 Compartment walls, compartment floors,
Introduction. CE marked construction products
Introduction This Technical Booklet has been prepared by the Department of Finance and Personnel and provides for certain methods and standards of building which, if followed, will satisfy the requirements
GENERAL FIRE SAFETY TERMS & DEFINITIONS
UCL Fire Technical Note - TN006 Fire Safety Technical Guide GENERAL FIRE SAFETY TERMS & DEFINITIONS Reference: BS4422-2005 Fire Safety Vocabulary - for further information and definitions BS EN ISO 13943-2000:
Guide to Houses in Multiple Occupation Self Contained Flats
Guide to Houses in Multiple Occupation Self Contained Flats Kitchens Bathrooms Fire Safety Room Sizes Toilets HMO self contained flat std0 Version 4 201106 INTRODUCTION GENERAL INFORMATION The Housing
The terms hazard and risk are often used, which we define as the following:
Fire Safety Last updated in October 2010 This information sheet aims to give safety reps a basic understanding of fire safety and fire risk assessments under the current law. More detailed information
Fire safety for landlords
Fire safety for landlords Acting Acting to to Protect & Save Are you a landlord and confused about your responsibilities towards fire safety? The law and regulations can often seem complicated and grey.
Fire Evacuation Procedures Network Building, 97 Tottenham Court Road, London, W1
Network Building Fire Safety Management Plan & Fire Evacuation Procedures Contents 1.0 Introduction 2.0 Means of Escape in Case of Fire 3.0 Means for Giving Warning in Case of Fire 4.0 Means for Fighting
FURNITURE & FURNISHINGS - FIRE SAFETY STANDARDS
Fire Safety Technical Guide FURNITURE & FURNISHINGS - FIRE SAFETY STANDARDS 1.0. Introduction 1.1. Furniture and furnishings may significantly increase fire spread in rooms and those circulation spaces,
UPP Residential Services Fire Risk Assessment
UPP Residential Services Fire Risk Assessment TS11151-R02-DRAFT1 15 August 2011 for: Keynes College University Road Canterbury Kent Recommended latest review date 14 August 2011 Executive summary This
Grasshoppers Rugby Football Sports and Social Club. The Fire Risk Assessment
Grasshoppers Rugby Football Sports and Social Club The Fire Risk Assessment Revision 1 Dated: 15th February 2013 CONTENTS 1. PREMISES DETAILS 2. PREMISES PLAN 3. HAZARDS 4. HISTORY 5. MITIGATING THE EFFECTS
Overview of Hotel Fire Safety Requirements
Overview of Hotel Fire Safety Requirements in the Fire Code Susan Clarke, P.Eng. Office of the Fire Marshal - January 10, 2012 1 Agenda Regulation History - Hotels Fire Code Overview (Parts 1 to 8) Defined
ISLE OF MAN FIRE & RESCUE SERVICE FIRE PRECAUTIONS LOGBOOK. Website www.iomfire.com
ISLE OF MAN FIRE & RESCUE SERVICE FIRE PRECAUTIONS LOGBOOK Website www.iomfire.com ADDRESS OF PREMISES FIRE CERTIFICATE No. (where applicable).. LOCATION OF LOG BOOK. CONTENTS OF LOG BOOK Useful telephone
AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Pocket guide to. Fire Alarm Systems Design BS 5839-1. Standard
Pocket guide to Fire Alarm Systems Design BS 5839-1 Standard AVAILABLE TO DOWNLOAD ON THE APOLLO APP The Regulatory Reform (Fire Safety) Order (FSO) became law on 1 October 2006 Legally you must comply!
MINIMUM STANDARDS FOR HIGH-RISE BUILDINGS
CHAPTER 93 MINIMUM STANDARDS FOR HIGH-RISE BUILDINGS Note: Chapter 93 is entirely Seattle amendments to the International Fire Code and is not underlined. Point of Information The requirements of this
Fire risk assessment a guide for businesses
Fire risk assessment a guide for businesses Disclaimer Cornwall Fire and Rescue Service provide this guide to assist businesses to improve fire safety in their premises, but stress the person completing
FIRE RISK ASSESSMENT SW13 0HA
FIRE RISK ASSESSMENT at Carmichael Court Grove Road London SW13 0HA ON BEHALF OF Farrar Property Management Date of assessment: 14/01/2013 Recommended review date: January 2015 CONTENTS 1.0 INTRODUCTION
Services Enclosures and Protected Shafts - Maintaining Compartmentation
Introduction When a fire resisting element is used to provide fire compartmentation, every opening that allows services to pass through the element must be adequately protected by sealing, or fire stopping
HOUSING STANDARDS POLICY TRANSITION STATEMENT IMPLEMENTATION: OCTOBER 2015. May 2015
HOUSING STANDARDS POLICY TRANSITION STATEMENT IMPLEMENTATION: OCTOBER 2015 May 2015 MAYOR OF LONDON Housing Standards: Transition Policy Statement. On 25 March 2015 through a written ministerial statement,
c. As mandated by law, facilities must obtain and maintain valid zoning permits as well as permits for intended use.
Walmart Standards for Suppliers Section 7. Health and Safety 7. Health and Safety Suppliers must provide workers with a safe and healthy work environment. Suppliers must take proactive measures to prevent
BUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010
Building Control Charnwood Borough Council Southfield Road Loughborough LE11 2TN BUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010 Page 1 of 6 PURPOSE: This Guidance
Fire Policy and Procedures. Cañada Blanch Spanish School
Fire Policy and Procedures Cañada Blanch Spanish School SUMMARY 1. Introduction (p. 3) 2. Roles and responsibilities (p. 3) -- Headteacher -- Fire Team -- All staff -- Contractors 3. Fire procedures (p.
AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Fire Alarm Systems Design. a guide to BS5839
AVAILABLE TO DOWNLOAD ON THE APOLLO APP a guide to Fire Alarm Systems Design BS5839 Part1:2013 The Regulatory Reform (Fire Safety) Order (FSO) became law on 1 October 2006 Legally you must comply! What
1. Fire Safety Policy and Responsibilities. Consult the Employer s Fire Safety Policy and establish responsibilities of staff for fire safety.
Management Checklist 1. Fire Safety Policy and Responsibilities. Consult the Employer s Fire Safety Policy and establish responsibilities of staff for fire safety. 2. Fire Hazard and Risk Assessment. Use
LONDON BOROUGH OF BROMLEY STANDARDS FOR HOUSES IN MULTIPLE OCCUPATION (HMO) INTRODUCTION
LONDON BOROUGH OF BROMLEY STANDARDS FOR HOUSES IN MULTIPLE OCCUPATION (HMO) INTRODUCTION 1. Minimum Standards: This document sets out the minimum standards required in HMOs located within the London Borough
Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal
Ontario Fire Code SECTION 5.13 DIP TANKS Illustrated Commentary Office of the Ontario Fire Marshal Dip Tanks Illustrated Commentary 1 5.13.1. Location 5.13.1.1. Dip tank operations involving flammable
FIRE SAFETY REGISTER. Premises Name: Premises Address: Fire Safety Manager: Contact No. Kerry County Fire Service www.kerrycoco.ie
FIRE SAFETY REGISTER Premises Name: Premises Address: Fire Safety Manager: Contact No. Kerry County Fire Service www.kerrycoco.ie 1 CONTENTS Section Title Page 1.0 Introduction 3 2.0 Guidance for the completion
BS5839 Part 1:2002 Overview
BS5839 Part 1:2002 Overview 1 Contents Introduction So why is the current standard being revised? The brief for the new standard Changes to structure of current Standard Enhanced certification of Fire
Houses in Multiple Occupation
Houses in Multiple Occupation Houses in Multiple Occupation Foreword This document has been created to both encourage and advise landlords, property owners and agencies to understand the Houses in Multiple
FIRE RISK ASSESSMENT. The Workplace Fire Precautions Legislation
FIRE RISK ASSESSMENT The Workplace Fire Precautions Legislation The Fire Precautions (Workplace) Regulations 1997 The Fire Precautions (Workplace)(Amendment) Regulations 1999 The Management of Health and
1.1.4 The findings from Fire Risk Assessment must be incorporated into the FRAMS Action Plan to manage fire safety at each premise.
Fire Safety Policy 1.1 Policy Statement of Intent 1.1.1 Under the current UK Legislation (In England and Wales, the Regulatory Reform (Fire Safety) Order 2005, Fire (Scotland) Act 2005, Fire and Rescue
Proposed Residential Complex At Holding No. - 98, B.T. Road, Kolkata - 700090 Developer Premier Mica Mining And Manufacturing Company
RISK MANAGEMENT PLAN is an integral part of a modernized and sophisticated residential complex. No efforts will be spared in identifying the all possible risks and disasters, evaluating them, installing
Fire. The Fire Installers Mate. A guide to fire alarm systems design
Fire The Fire Installers Mate A guide to fire alarm systems design BS 5839 Part 1:2002 A guide to BS 5839 Part 1:2002 Disclaimer This booklet is not intended to be a comprehensive guide to all aspects
Ch. 58 DIVISION D-O 34 CHAPTER 58. DIVISION D-O ORDINARY COMMERCIAL, INDUSTRIAL, OFFICE OCCUPANCY GROUP CONSTRUCTION TYPE MAXIMUM STORY HEIGHT
Ch. 58 DIVISION D-O 34 CHAPTER 58. DIVISION D-O ORDINARY COMMERCIAL, INDUSTRIAL, OFFICE Sec. 58.1. Division D-O occupancies. 58.2. Separation and mixed occupancy. OCCUPANCY GROUP CONSTRUCTION TYPE MAXIMUM
EMERGENCY ACTION, EVACUATION AND FIRE PREVENTION SAFETY PROGRAM
EMERGENCY ACTION, EVACUATION AND FIRE PREVENTION SAFETY PROGRAM REGULATORY STANDARD: OSHA - 29CFR1910.36-29CFR1910.38-29CFR1910.157-29CFR1910.165 NFPA-10 BASIS: The OSHA Emergency Action Planning and the
PLYMOUTH COMMUNITY HOMES. Fire Safety Management Policy
PLYMOUTH COMMUNITY HOMES Fire Safety Management Policy 1 Version 2 dated March 2012 FOREWORD This document details the system for the management of fire safety risks in properties owned and/or managed
Bastille Court 2 Paris Garden London SE1 8ND Telephone: 020 7902 5314 Fax: 020 7902 5301 E-mail: [email protected] Web: http://www.thefpa.co.
Bastille Court 2 Paris Garden London SE1 8ND Telephone: 020 7902 5314 Fax: 020 7902 5301 E-mail: [email protected] Web: http://www.thefpa.co.uk Fire Risk Assessment Course Health & Safety at Work Inspectorate,
Building Control Guidance Note
Issued 01/10/10 Rev Page 1 A new updated version of Approved Document B comes into force from the 6 th April 2007. This revised guidance is split into two separate documents:- Volume 1 Dwelling Houses
FIRE RISK ASSESSMENT COMPETENCY COUNCIL
FIRE RISK ASSESSMENT COMPETENCY COUNCIL Competency Criteria for Fire Risk Assessors Version 1 Published : 21/12/11 Page 1 Foreword Fire safety legislation requires that, for most premises except private
A Guide to Fire and Security Protection in Multi-Occupied Residential Properties
A Guide to Fire and Security Protection in Multi-Occupied Residential Properties Advice for Property Owners, Managers and Contractors Revision 2015 Foreword HOMESTAMP is a partnership consortium with an
Fire Strategy. Oak Park Care Home and Extra Care Block. 21 July 2015
21 July 2015 Revision History Version Date Author Comments 1 21/07/2015 Anthony Robson First Issue Contents EXECUTIVE SUMMARY 1 1 INTRODUCTION 1 2 PROJECT INFORMATION 2 3 MEANS OF ESCAPE 3 Document Reference
Fire safety in purpose-built blocks of flats
Fire safety in purpose-built blocks of flats Environment, housing, planning and waste Foreword Flats have been used to house people since Victorian times. From the early tenements for the poor to mansion
SBR FIRE RISK ASSESSMENT
SBR FIRE RISK ASSESSMENT Report of audit and inspection Premises Details Occupier Premises Address Premises Description Times premises are in use Use and maximum no. people present The British School of
Landlord s Fire Risk Assessment Guidance Manual
Do-it-Yourself Kit Landlord s Fire Risk Assessment Guidance Manual by Rick Lawton, SIIRSM, TIFireE, TIFSM and David Smith LLB of Anthony Gold Solicitors 2 Landlord s Fire Risk Assessment Important Facts
PRACTICAL FIRE SAFETY GUIDANCE FOR MEDIUM AND LARGE PREMISES PROVIDING SLEEPING ACCOMMODATION
PRACTICAL FIRE SAFETY GUIDANCE FOR MEDIUM AND LARGE PREMISES PROVIDING SLEEPING ACCOMMODATION Revised February 2008 Practical Fire Safety Guidance For Medium And Large Premises Providing Sleeping The guidance
Fire Risk Assessment Tool
Fire Risk Assessment Tool DATE OF ASSESSMENT PLANNED REVIEW DATE www.twfire.gov.uk Introduction The Regulatory Reform (Fire Safety) Order 2005 (FSO) replaced previous fire safety legislation. Where the
CITY OF FAIRFAX CODE ADMINISTRATION 703-385-7830 / FAX 703-385-9265 www.fairfaxva.gov
CITY OF FAIRFAX CODE ADMINISTRATION 703-385-7830 / FAX 703-385-9265 www.fairfaxva.gov Finishing a basement to make additional living space in a house is a popular construction project for many homeowners.
1.1. EMERGENCY PROCEDURE On discovering a fire or being informed of an emergency;
Fire Action Plan FIRE ACTION PLAN SEStran aims to provide and maintain safe & healthy working conditions, equipment and systems of work for all our employees, and to provide such information, training
MINNESOTA HEALTH CARE ENGINEERS IN ASSISTED LIVING FACILITIES
MINNESOTA HEALTH CARE ENGINEERS FIRE/LIFE SAFETY IN ASSISTED LIVING FACILITIES September 13, 2012 MINNESOTA HEALTH CARE ENGINEERS FIRE/LIFE SAFETY IN ASSISTED LIVING FACILITIES WELCOME Exits Restrooms
ENVIRONMENTAL HEALTH PROFESSIONAL PRACTICE VOL II CHAPTER III. HOUSES IN MULTIPLE OCCUPATION Space Standards
ENVIRONMENTAL HEALTH PROFESSIONAL PRACTICE VOL II CHAPTER III HOUSES IN MULTIPLE OCCUPATION Space Standards ADOPTED HOUSING STANDARDS:CATEGORY F HOUSES Houses within this category would be of a low priority
IFE Level 4 Certificate in Fire Science and Fire Safety (HL)
IFE Level 4 Certificate in Fire Science and Fire Safety (HL) Unit 2: Fire Safety Unit Reference Number: D/505/5932 Introduction This unit focuses on the prevention and detection of fire in premises and
The Types of Standard 2 Guidance on the Standards 2 Changes to Legislation 2
CONTENTS INTRODUCTION 2 The Types of Standard 2 Guidance on the Standards 2 Changes to Legislation 2 SCOTTISH CORE STANDARDS FOR ACCREDITED LANDLORDS 3 1 Communication with the Tenant 3 2 Equality Issues,
Landlord/Agent Code of Conduct
Landlord/Agent Code of Conduct Commitment to this is a requirement of the Home Stamp accreditation scheme The Home Stamp Code of Conduct aims to provide guidance and advice regarding the management of
1. Introduction 3. 2. Scope and Application 5
Contents 1. Introduction 3 1.1 Reason for this Guide 1.2 Interpretation 1.3 Principles of fire safety 1.4 Legal provisions 2. Scope and Application 5 2.1 Scope of the Guide 2.2 Premises to which the Guide
Fire Standards & Regulations Are you confused?
Fire Standards & Regulations Are you confused? Regulatory Reform (Fire Safety) Order Local Licensing Requirements BS 5839-6: 2013 Building Regulations Document B LACORS Fire Safety Guidance Fire Alarm
Minimum Housing and Health Standards
APPENDIX M.O. 57/2012 Minimum Housing and Health Standards Original version July 20, 1999. Revisions to Part lll, Housing Premises, sections 3 and 4, June 30, 2012 (all revisions are bolded and underlined).
Fire Safety Log Book
Fire Safety Log Book Company... Address........ Responsible Person. Competent Person. Date Started For Additional Information: Safety Management (UK) Ltd Holme Suite, Clawthorpe Hall Business Centre, Burton
Building Codes Update: The 2009 International Fire Code and the Apartment Industry
! Building Codes Update: The 2009 International Fire Code and the Apartment Industry Apartment operators and developers should be aware of organizational changes in the 2009 edition of the International
The risk assessment of fire damper installations
The risk assessment of fire damper installations June 2010 Paul White OVERVIEW OVERVIEW The purpose of this presentation is to highlight that fire dampers form a key part of the passive fire protection
Fire doors guidance. Safety and Health Services. Document control information. Date issued: January 2011. Version: 2. Previous review dates: 2011
Document control information Fire doors guidance Published document name: Firedoors-gn.pdf Date issued: January 2011 Version: 2 Previous review dates: 2011 Next review date: Related documents: Governing
Caravan Sites and Control of Development Act 1960. Permanent Residential Mobile Home Sites Licence Conditions
Caravan Sites and Control of Development Act 1960 Permanent Residential Mobile Home Sites Licence Conditions 1 Permanent Residential Mobile Home Site Licence Conditions Caravan Sites and Control of Development
Fire Risk Assessment for Simple Premises Guidance Notes
Fire Risk Assessment for Simple Premises Guidance Notes The UK s national fire safety organisation Protecting people, property, business and the environment Introduction This guide and the accompanying
FLAMMABLE LIQUIDS COMPLIANCE NOTE
Issued by: Heather Rice Page: 1 of 7 COMPLIANCE NOTE INTRODUCTION This document provides additional guidance to support the Arrangement on Flammable Liquids (Ref No. CYC/HS/A27) CONTENTS Section Topic