1 Technical Information Manual Revision n.1 4 January 2004 Mod.
2 Table of Contents TABLE OF CONTENTS... I 1 GENERAL DESCRIPTION OVERVIEW MAIN TECHNICAL SPECIFICATIONS FUNCTIONAL DESCRIPTION TECHNICAL SPECIFICATION PACKAGING EXTERNAL CONNECTIONS BACKPLANE CONNECTORS FRONT PANEL CONNECTORS RS232 INTERFACE COMMANDS Write_Mk Read_Mk Write_Dac Read Cnt T_Win Test Pulse Read_Ch SOFTWARE INTERFACE SET DISCRIMINATOR THRESHOLD MASK CHANNELS COUNT CHANNELS HITS TEST PULSE MULTIPLEX ONE CHANNEL TO OUTPUT...18 Trigger ICARUS group INFN-sezione di Napoli I
3 1 General description 1.1 Overview The Local Trigger Contro Unit is a 18 channels analog board. It receives as input 9+9 Analog Wire Sum coming from the V791 boards (generally 9 of 2 nd Induction and 9 of collection). It discriminates the 18 inputs comparing them with a remotely controlled threshold (one for each). Noisy inputs can be masked. LTCU gives as output two trigger proposals (T 0 and T 1 ), each one coming from Fast OR of 9 inputs. It measures the rate of trigger proposals for each input. It is remotely controlled through RS232. The board is housed in a 1-unit wide, 6-unit high Eurocard mechanics. The module hosts nine external connectors: A 64 pin input connector (rear panel), A 30 pin power supply connector (rear panel) A RS232 connector A RJ11 connector to transfer FAST OR A RJ11 connector to read a remote selected channel A RJ45 connector for dedicated bus Three 16 pin connectors to read channels 1.2 Main technical specifications Parameter Number of input channels 18 Input bandwidth frequency > 10 khz Oscillator frequency 10 MHz Threshold range mv DAC resolution ~ 1mV Output data 2 bits Tab. 1 Model LTCU main functional specifications Trigger ICARUS group INFN-sezione di Napoli 1
4 2 Functional description RS232 Interface XILINX Spartan 2 RS232 I/O RS232 Connector Fired Channel Recorder F_OR 2 RJ11 OR Connector Thresholds DAC DAC DAC Test Pulse 4 MASK MUX 18x1 RJ11 Channel Output Connector 18 ASUM Input Discriminators output 18 Discriminators Fig. 1 Block diagram of the model LTCU. Fig. 1 shows a detailed block diagram of the LTCU module. The discriminators provide a comparison of input signals with remotely set thresholds. The external DAC allows to set these thresholds. On the board there are three DAC chips. Each one has 6 channels. It is possible to set each discriminator and each channel individually. The discriminated signals are sent to the FAST OR block. This block produces two signals: T 0 which is the OR between 9 AWS from 2 nd Induction plane and T 1 which is the OR between 9 AWS from collection plane). The OR output connector on the front panel provides the two ORs. The discriminated data are sent to a Multiplexer. It is possible to select one of the 18 discriminator output from a remote PC. Data are also sent to the Fired channel recorder which counts the number of hits for each channel in a time window. The user can define time window from a PC. A test pulse allows to test different groups of input channels. RS232 allows to enable test pulsing on one of following groups of channels: 0 4, 5 8, 9 13, MASK block allows to mask noisy channels through RS232 remote control. Trigger ICARUS group INFN-sezione di Napoli 2
5 3 Technical specification 3.1 Packaging The board is housed in a 1-unit wide, 6-unit high Eurocard standard mechanics. The front panel of the LTCU is shown in Fig. 2 The module hosts nine external connectors: Rear part of the module: Front panel: 64 pin input connector; 30 pin power supply and auxiliary signal connector; RS232 Connector RJ11 Connector ( Fast OR output) RJ11 Connector (Multiplexed channel output ) RJ45 Connector (Dedicated bus reserved) Three 16 pin connectors (Analog sum inputs) Please note that, although the module is housed in a Eurocard standard mechanics, the rear connectors are not VME standard connectors since the backplane for which the board has been designed is proprietary. Trigger ICARUS group INFN-sezione di Napoli 3
6 LTCU FAST OR OUT Analog sum input Multiplexed channel output Dedicated bus connector RS232 Connector Fig. 2 Front panel of the LTCU Trigger ICARUS group INFN-sezione di Napoli 4
7 3.2 External Connections The external connection pin configurations of LTCU are shown in Fig. 3 and Fig. 4, while their function and electro-mechanical specification are listed in the following sections. 1A 1B 1C VCC VCC AVCC AVCC BVCC BVCC INPUT CONNECTOR (P1) Fig. 3 Pin configuration of the backplane connectors on the LTCU Trigger ICARUS group INFN-sezione di Napoli 5
8 DT0 NDTO DT1 NDT1 DT2 NDT2 DT3 NDT3 RJ45 RX TX RS232 CONNECTOR CH0 CH1 CH2 CH3 CH4 CH5 1A 1B J1 OR1 NOR1 OR2 NOR2 RJ11 LK NLK TT NTT RJ11 CH6 CH7 CH8 1A 1B CH9 CH10 CH11 J2 CH12 CH13 CH14 CH15 CH16 CH18 Fig. 4 Pin Configuration of front panel connector 1A J3 1B 3.3 Backplane connectors INPUT CONNECTOR (P3) Mechanical specification: 64 pin, C-type, A/C lines, DIN41612 standard connector; Electrical specifications: AIN0...AIN31 : not in use A : common terminal Trigger ICARUS group INFN-sezione di Napoli 6
9 POWER SUPPLY CONNECTOR (P1) Mechanical specification: 30 pin, C-type, A/B/C lines, DIN41612 standard connector; Electrical specifications: VCC: +5V for digital section AVCC: - 5V for analogic section BVCC: +5V for analogic section : common terminal 3.4 Front panel connectors INPUT CHANNEL CONNECTOR (J1, J2, J3) Mechanics specification: 16 pin, A/B lines, DIN standard connector; Electrical specification: CHN...CH(N+5): input channels : common terminal RJ11 (FAST OR) Mechanichs specification: RJ11 type connector; Electrical specification: OR1, OR2 : FAST OR output NOR1, NOR2: FAST OR inverted RJ11 (Channel output) Mechanichs specification: RJ11 type connector; Electrical specification: LK : selected channel output TT : not in use NLK: selected channel inverted LTT: not in use RJ45 (dedicated bus connector) Mechanichs specification: RJ45 type connector; Electrical specification: DT0..1: input data DT2..3: output data NDT0..1: input data inverted NDT2..3: output data inverted Trigger ICARUS group INFN-sezione di Napoli 7
10 RS232 Connector Mechanichs specification: 9 pin D-type connector; Electrical specification: RS232 signals. Trigger ICARUS group INFN-sezione di Napoli 8
11 4 RS232 Interface The LTCU can be remotely controlled by a standard PC via RS232 interface. The default setting of the RS232 interface are listed in Tab Commands Baud rate 9600 Parity None Character Lenght 8 bits Number of stop bits 1 bit Tab. 2 RS232 Port setting The LTCU module has 7 functional modes. The user can define the functional mode setting (through PC remote control) a special byte, Control Word. The Control word definition is listed in Tab. 3. Control Word byte Command Operation Write_Mk Mask input channel Read_Mk Read which channels are masked Write_Dac Set descriminators threshold Read_Cnt Read channel hits from memory XX Test_P Test pulse mode (2 LS bits to select channels to test) XX T_Win Set time window to count fired input (2 LS bits to select time window width) Read_Ch Read selected discriminator output Tab. 3 Control word definition After CW, logic accepts different number of byte depending on the kind of operation (Tab. 4). Command Write_Mk Read_Mk Write_Dac Read_Cnt T_Win Test_P Read_Ch Tab. 4 Bytes request for each operation. Number of byte 1Control Word+3 byte data 1 Control Word 1 Control Word +2 byte data 1 Control Word +1 byte data 1 Control Word 1 Control Word 1 Control Word +1 byte data Trigger ICARUS group INFN-sezione di Napoli 9
12 4.1.1 Write_Mk This operation permits to mask noisy inputs. Following you find the sequence of data you have to set using PC remote control. Bytes of data define which channel you want to mask Control Word Ch7 Ch6 Ch5 Ch4 Ch3 Ch2 Ch1 Ch0 Ch15 Ch14 Ch13 Ch12 Ch11 Ch10 Ch9 Ch8 Data Bytes Ch17 Ch Read_Mk This operation permits to read which channels are masked. It needs only one Control word Control Word Write_Dac This operation permits to set discriminators threshold Control Word D7 D6 D5 D4 D3 D2 D1 D0 Data Byte x x x A1 A0 Ch2 Ch1 Ch0 Address Byte A1..A0: Ch2..Ch0: D7..D0: Address to select the DAC chip on the board. Address to select the DAC channel on the selected chip. Threshold code. Trigger ICARUS group INFN-sezione di Napoli 10
13 4.1.4 Read Cnt This command allows to read the number of hits on the channels recorded in a time window Control Word x x x I/C Ch3 Ch2 Ch1 Ch0 Data Byte I/C: Induction II (0) or Collection (1) plane selection Ch3..Ch0: Channel selection T_Win It permits to select different time windows w w Control Word ww defines the time window length as shown in Tab. 5. ww Value (s) Tab. 5 Time window lenght selection Test Pulse This command permits to send a test Pulse to different groups of discriminator input p p Control Word pp defines the input group selected as shown in Tab. 6 pp Channels # Tab. 6 Channels selection Trigger ICARUS group INFN-sezione di Napoli 11
14 4.1.7 Read_Ch It permits to read discriminator output Control Word x x x Ch4 Ch3 Ch2 Ch1 Ch0 Data Byte Ch4..Ch0: Address to select the channel to read. Trigger ICARUS group INFN-sezione di Napoli 12
15 5 Software Interface It is possible to select the operation pressing the push button on the left of the panel (Fig. 5). The operations, which are sent on selectable COM port, are explained in Tab. 7. Fig. 5 Software Interface front panel Operations Set discriminator threshold Mask channels Counts channels hits Test pulse Multiplex one channel to output Tab. 7 Software operations Trigger ICARUS group INFN-sezione di Napoli 13
16 5.1 Set discriminator threshold Fig. 6 shows the Set discriminator threshold panel. Only enabled DAC channels are set when Send button is pushed. All the channels can be set together. Fig. 6 DAC threshold controller panel Trigger ICARUS group INFN-sezione di Napoli 14
17 5.2 Mask channels Fig. 7 shows the Set Mask channels panel. It permits to mask or unmask channels or monitor the status of the mask. By default all channels are masked. Fig. 7 Mask channels front panel Trigger ICARUS group INFN-sezione di Napoli 15
18 5.3 Count channels hits Fig. 8 shows the Count channels hits panel. It permits to select the time window in which the hits are counted and the channels to be read. The number of counts can be also selected. For each channels the controller shows the histogram of hits, the mean value and the RMS value. Fig. 8 Counts channels hits panel Trigger ICARUS group INFN-sezione di Napoli 16
19 5.4 Test pulse Fig. 9 shows the Test pulse panel. It is possible to select which channels to test. Fig. 9 Test pulse panel Trigger ICARUS group INFN-sezione di Napoli 17
20 5.5 Multiplex one channel to output Fig. 10 shows the Multiplex one channel to output panel. It permits to select which channel to read. Fig. 10 Multiplex one channel to output panel Trigger ICARUS group INFN-sezione di Napoli 18
T3 Mux M13 Multiplexer
T3 Mux M13 Multiplexer User Manual [Type the abstract of the document here. The abstract is typically a short summary of the contents of the document. Type the abstract of the document here. The abstract
More informationEVAL-UFDC-1/UFDC-1M-16
Evaluation Board for Universal Frequency-to- Digital Converters UFDC-1 and UFDC-1M-16 EVAL-UFDC-1/UFDC-1M-16 FEATURES Full-Featured Evaluation Board for the Universal Frequency-to-Digital Converters UFDC-1
More informationProgramming and Using the Courier V.Everything Modem for Remote Operation of DDF6000
Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000 1.0 Introduction A Technical Application Note from Doppler System July 5, 1999 Version 3.x of the DDF6000, running version
More informationJNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
More informationTechnical Information Manual
Technical Information Manual Revision n. 3 26 September 2003 MOD. V538 A series 8 CHANNEL NIM-ECL / ECL-NIM TRANSLATORS AND FAN OUT CAEN will repair or replace any product within the guarantee period if
More informationMANUAL FOR RX700 LR and NR
MANUAL FOR RX700 LR and NR 2013, November 11 Revision/ updates Date, updates, and person Revision 1.2 03-12-2013, By Patrick M Affected pages, ETC ALL Content Revision/ updates... 1 Preface... 2 Technical
More informationLab Experiment 1: The LPC 2148 Education Board
Lab Experiment 1: The LPC 2148 Education Board 1 Introduction The aim of this course ECE 425L is to help you understand and utilize the functionalities of ARM7TDMI LPC2148 microcontroller. To do that,
More informationBIODEX ADDENDUM BIODEX EMG/ANALOG SIGNAL ACCESS CONFIGURATION UTILITY SOFTWARE FOR SYSTEM 3 REVISION 2 AND SYSTEM 4 DYNAMOMETERS
ADDENDUM BIODEX EMG/ANALOG SIGNAL ACCESS CONFIGURATION UTILITY SOFTWARE FOR SYSTEM 3 REVISION 2 AND SYSTEM 4 DYNAMOMETERS 830-000 835-000 840-000 850-000 BIODEX Biodex Medical Systems, Inc. 20 Ramsey Road,
More informationUsing HyperTerminal with Agilent General Purpose Instruments
Using HyperTerminal with Agilent General Purpose Instruments Windows HyperTerminal can be used to program most General Purpose Instruments (not the 531xx series counters) using the RS-232 Serial Bus. Instrument
More informationApplication/Connection Examples
This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.
More informationHow To Use A High Definition Oscilloscope
PRELIMINARY High Definition Oscilloscopes HDO4000 and HDO6000 Key Features 12-bit ADC resolution, up to 15-bit with enhanced resolution 200 MHz, 350 MHz, 500 MHz, 1 GHz bandwidths Long Memory up to 250
More informationToshiba Serial Driver Help. 2012 Kepware Technologies
2012 Kepware Technologies 2 Table of Contents Table of Contents 2 3 Overview 3 Device Setup 4 Modem Setup 4 Cable Diagram - EX100/200 PLCs 4 Cable Diagram - T1 PLCs 5 Cable Diagram - T2/T3 PLCs 5 Cable
More informationSerial Communications
April 2014 7 Serial Communications Objectives - To be familiar with the USART (RS-232) protocol. - To be able to transfer data from PIC-PC, PC-PIC and PIC-PIC. - To test serial communications with virtual
More informationSYMETRIX SOLUTIONS: TECH TIP August 2015
String Output Modules The purpose of this document is to provide an understanding of operation and configuration of the two different String Output modules available within SymNet Composer. The two different
More informationMicrocontroller Based Low Cost Portable PC Mouse and Keyboard Tester
Leonardo Journal of Sciences ISSN 1583-0233 Issue 20, January-June 2012 p. 31-36 Microcontroller Based Low Cost Portable PC Mouse and Keyboard Tester Ganesh Sunil NHIVEKAR *, and Ravidra Ramchandra MUDHOLKAR
More informationSingle channel data transceiver module WIZ2-434
Single channel data transceiver module WIZ2-434 Available models: WIZ2-434-RS: data input by RS232 (±12V) logic, 9-15V supply WIZ2-434-RSB: same as above, but in a plastic shell. The WIZ2-434-x modules
More informationPOCKET SCOPE 2. The idea 2. Design criteria 3
POCKET SCOPE 2 The idea 2 Design criteria 3 Microcontroller requirements 3 The microcontroller must have speed. 3 The microcontroller must have RAM. 3 The microcontroller must have secure Flash. 3 The
More informationUS-SPI New generation of High performances Ultrasonic device
US-SPI New generation of High performances Ultrasonic device Lecoeur Electronique - 19, Rue de Courtenay - 45220 CHUELLES - Tel. : +33 ( 0)2 38 94 28 30 - Fax : +33 (0)2 38 94 29 67 US-SPI Ultrasound device
More informationDS1621 Digital Thermometer and Thermostat
Digital Thermometer and Thermostat www.dalsemi.com FEATURES Temperature measurements require no external components Measures temperatures from 55 C to +125 C in 0.5 C increments. Fahrenheit equivalent
More informationT-BOXN12R. First steps with T-BOXN12R. You can make it wireless. Date: 2004-07-16 Version 1.0
T-BOXN12R You can make it wireless First steps with T-BOXN12R Date: 2004-07-16 Version 1.0 Content 1. Purpose of this document... 3 2. T-BoxN12R overview... 4 3. First step... 5 3.1. Preparing your workshop
More informationQuick Start Guide for High Voltage Solar Inverter DC-AC Board EVM. Version 1.3
Quick Start Guide for High Voltage Solar Inverter DC-AC Board EVM Version 1.3 Introduction This document talks about the quick start principles for the high voltage solar inverter DC-AC board. From this
More informationSenseLink TM. End-Point Controller. Addendum
SenseLink TM End-Point Controller Addendum MKS Instruments, Inc. Control & Information Technology Products Group 3350 Scott Blvd Bldg 4 Santa Clara, CA 95054 Main: 408.235.7620 Fax: 408.235.7625 SenseLink
More informationENET-710. ENET-710 - Ethernet Module ENET-710 JAN / 06 FOUNDATION
ENET-710 ENET-710 - Ethernet Module JAN / 06 ENET-710 FOUNDATION E N E T 7 1 0 ME smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is
More informationTCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL w w w. c d v g r o u p. c o m CA-ETHR-A: TCP/IP Module Installation Manual Page Table of Contents Introduction...5 Hardware Components... 6 Technical Specifications...
More informationHDO700 P FIBRE OPTIC TRANSMITTER
Timo Rantanen 18.1.2011 1(5) HDO700 P FIBRE OPTIC TRANSMITTER HDO700 P is a high performance, extremely linear externally modulated 1550 nm transmitter for HDO fibre optic CATV link. This transmitter type
More informationNC-12 Modbus Application
NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1
More informationRCC2 Test Proceedures
RCC2 Test Proceedures 1. Power-up Test 1. install board in VME crate (6U style or 6U section of 9U) and turn on power 2. check that cfg LED (D4) on front panel and D3 LED on board near U47 are lit (red)
More informationThe GV-I/O Box 8 Ports provides 8 inputs and 8 relay outputs, and supports both DC and AC output voltages.
GV-I/O Box 8 Ports The GV-I/O Box 8 Ports provides 8 inputs and 8 relay outputs, and supports both DC and AC output voltages. Key Features 8 inputs and 8 outputs are provided. Up to 9 pieces of GV-I/O
More informationDAM Series DAM124 4DIN+8AI+4DO Module Model No.:DAM124 WebSite: www.gsm-m2m.com
DAM Series DAM124 4DIN+8AI+4DO Module Model No.:DAM124 WebSite: www.gsm-m2m.com This handbook has been designed as a guide to the installation and operation of King Pigeon Hi-Tech.Co.,Ltd DAM series. Statements
More informationSmarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION
Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION The Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier is a multi-functional compact device. It
More informationWA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide
WA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide Version 2.1, 4/2010 Disclaimer While every effort has been made to ensure that the information in this guide is accurate
More informationBIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter
BIT COMMANDER Serial RS232 / RS485 to Ethernet Converter (Part US2000A) Copyrights U.S. Converters 1 Contents Overview and Features... 3 Functions..5 TCP Server Mode... 5 Httpd Client Mode.5 TCP Auto mode....6
More informationQuick Installation. A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding. Quick Installation
Quick Installation A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding This chapter intends to get your new FuzzyScan scanner working with your existing system within minutes. General instructions
More informationKnowledge Base Article. Integrating ISONAS Access Control System with TagMaster LR-series RFID Readers
Knowledge Base Article Integrating ISONAS Access Control System with TagMaster LR-series RFID Readers Copyright 2009-2012, ISONAS Security Systems All rights reserved Table of Contents 1: INTRODUCTION...
More informationTechnical Information POWER PLANT CONTROLLER
Technical Information POWER PLANT CONTROLLER Content The Power Plant Controller offers intelligent and flexible solutions for the control of all PV power plants in the megawatt range. It is suitable for
More informationThe GV-I/O Box 16 Ports provides 16 inputs and 16 relay outputs, and supports both DC and AC output voltages.
GV-I/O Box 16 Ports The GV-I/O Box 16 Ports provides 16 inputs and 16 relay outputs, and supports both DC and AC output voltages. Key Features 16 inputs and 16 outputs are provided. Up to 9 pieces of GV-I/O
More informationSerial Communications
Serial Communications 1 Serial Communication Introduction Serial communication buses Asynchronous and synchronous communication UART block diagram UART clock requirements Programming the UARTs Operation
More informationAtmel Norway 2005. XMEGA Introduction
Atmel Norway 005 XMEGA Introduction XMEGA XMEGA targets Leadership on Peripheral Performance Leadership in Low Power Consumption Extending AVR market reach XMEGA AVR family 44-100 pin packages 16K 51K
More informationTo perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:
PURPOSE Verify that communication is established for the following products programming option (488.2 compliant, SCPI only): DCS - M9C & DCS M130, DLM M9E & DLM-M9G & DLM M130, DHP - M9D, P series, SG,
More informationKSH-3000-MI. Swipe Card Reader. ( Magnetic / IC Card two in One Reader ) Revision Reason Date V2.0 03-16-2006
KSH-3000-MI Swipe Card Reader ( Magnetic / IC Card two in One Reader ) Version: V2.7 Revision Reason Date V2.0 03-16-2006 V2.1 1. Update mechanical drawing 04-09-2006 V2.2 1. Update KSH-3000-061 drawing
More informationDK40 Datasheet & Hardware manual Version 2
DK40 Datasheet & Hardware manual Version 2 IPC@CHIP DK40 Evaluation module Beck IPC GmbH http://www.bcl.de page 1 of 11 Table of contents Table of contents... 2 Basic description... 3 Characteristics...
More information2-Pair. Managed SHDSL Ethernet Extender. User s Manual
2-Pair User s Manual 1. Quick Start Guide This quick start guide describes how to install and use the Managed SHDSL Ethernet Extender. This is the Ethernet Extender of choice to extend 10/100 Ethernet
More informationVoice Over Internet Protocol (VoIP) Configuration
(VoIP) Configuration ENGINEERING REPORT No: 02-003 Introduction This report describes interfacing the IPCS VoIP Gateway Model EGW-902 to an ESTeem Model 192E Wireless Ethernet radio modem in a demonstration
More informationPM1122 INT DIGITAL INTERFACE REMOTE
PM1122 INT DIGITAL INTERFACE REMOTE PM1122 INT front panel description: 1. Clear wireless remotes knob: push this button for more than 2 seconds to clear the list of all assigned wireless remote settings
More informationCHAPTER 11: Flip Flops
CHAPTER 11: Flip Flops In this chapter, you will be building the part of the circuit that controls the command sequencing. The required circuit must operate the counter and the memory chip. When the teach
More informationDUKANE Intelligent Assembly Solutions
PC Configuration Requirements: Configuration Requirements for ipc Operation The hardware and operating system of the PC must comply with a list of minimum requirements for proper operation with the ipc
More informationModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.
IntesisBox ModBus Server - KNX Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems. Integrate KNX based lighting control into your SCADA, BMS, PLC "talking" Modbus. Master
More informationNETWORK ENABLED EQUIPMENT MONITOR
NETWORK ENABLED EQUIPMENT MONITOR Remotely Monitor Sensors over the Internet Connect Sensors to the Web to Remotely Monitor Equipment, Processes or Other Applications A Complete, Easy to Deploy, Stand-Alone
More informationModbus Communications for PanelView Terminals
User Guide Modbus Communications for PanelView Terminals Introduction This document describes how to connect and configure communications for the Modbus versions of the PanelView terminals. This document
More informationHARDWARE MANUAL. BrightSign HD120, HD220, HD1020. BrightSign, LLC. 16795 Lark Ave., Suite 200 Los Gatos, CA 95032 408-852-9263 www.brightsign.
HARDWARE MANUAL BrightSign HD120, HD220, HD1020 BrightSign, LLC. 16795 Lark Ave., Suite 200 Los Gatos, CA 95032 408-852-9263 www.brightsign.biz TABLE OF CONTENTS OVERVIEW... 1 Block Diagram... 2 Ports...
More informationAlcatel-Lucent OmniPCX Enterprise Communication Server TA-MMK (MMK V2)
Alcatel-Lucent OmniPCX Enterprise Communication Server TA-MMK (MMK V2) Legal notice: Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of Alcatel-Lucent. All other trademarks are
More informationRDF1. RF Receiver Decoder. Features. Applications. Description. Ordering Information. Part Number Description Packages available
RDF1 RF Receiver Decoder Features Complete FM Receiver and Decoder. Small Form Factor Range up to 200 Metres* Easy Learn Transmitter Feature. Learns 40 transmitter Switches 4 Digital and 1 Serial Data
More informationEthernet. Customer Provided Equipment Configuring the Ethernet port.
Installing the RDSP-3000A-NIST Master Clock. Ethernet Connect the RJ-45 connector to a TCP/IP network. Equipment The following equipment comes with the clock system: RDSP-3000A-NIST Master Clock Module.
More informationChapter 5 Cubix XP4 Blade Server
Chapter 5 Cubix XP4 Blade Server Introduction Cubix designed the XP4 Blade Server to fit inside a BladeStation enclosure. The Blade Server features one or two Intel Pentium 4 Xeon processors, the Intel
More information[F/T] [5] [KHz] [AMP] [3] [V] 4 ) To set DC offset to -2.5V press the following keys [OFS] [+/-] [2] [.] [5] [V]
FG085 minidds Function Generator Manual of Operation Applicable Models: 08501, 08501K, 08502K, 08503, 08503K Applicable Firmware Version: 1 ) 113-08501-100 or later (for U5) 2 ) 113-08502-030 or later
More informationDescription: Multiparameter System (4 or 8 channels)
Model MPA4, 8 ch acquisition system with 6 ns time tagging The MPA4 is a Multiparameter Data Acquisition System Description: Multiparameter System (4 or 8 channels) ADC Settings and Presets Dialog The
More informationLAN / WAN Connection Of Instruments with Serial Interface By Using a Terminal Server
Products: EFA with EFA Scan, DVRM and DVMD with Realtime Monitor or Stream Explorer DVMD-B1 LAN / WAN Connection Of Instruments with Serial Interface By Using a Terminal Server Remote control of test and
More informationDisturbance Recoder SPCR 8C27. Product Guide
Issued: April 1999 Status: Updated Version: C/26.04.2006 Data subject to change without notice Features Versatile digital disturbance recorder module for recording various phenomena in the electric power
More informationUS-Key New generation of High performances Ultrasonic device
US-Key New generation of High performances Ultrasonic device US-Key connected to a laptop computer US-Key Ultrasound device single channel Features USB2 High Speed connection Ultralow noise preamplifier
More informationDS1621 Digital Thermometer and Thermostat
www.maxim-ic.com FEATURES Temperature measurements require no external components Measures temperatures from -55 C to +125 C in 0.5 C increments. Fahrenheit equivalent is -67 F to 257 F in 0.9 F increments
More informationHCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply
1. INTRODUCTION HCS-3300/3302/3304 USB Remote Programmable Laboratory Grade Switching Mode Power Supply User Manual This family of efficient, upgraded SMPS with small form factor, auto cross over CV CC,
More informationNTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter
NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter Description: The NTE2053 is a CMOS 8 bit successive approximation Analog to Digital converter in a 20 Lead DIP type package which uses a differential
More informationEZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014
EZmoto V2 Product description Rev. 6 10/01/2014 1 Contents 1. Overview... 3 2. Hardware Interface Description... 3 2.1 Main features of the EZmoto... 3 2.2 Hardware block diagram... 4 2.3 Internal Hardware
More informationSoftware User Guide UG-461
Software User Guide UG-461 One Technology Way P.O. Box 9106 Norwood, MA 02062-9106, U.S.A. Tel: 781.329.4700 Fax: 781.461.3113 www.analog.com ezlinx icoupler Isolated Interface Development Environment
More informationISDN Phone Lines with Metasys
Metasys Network Technical Manual 636 App. Notes: Network Communications Section Application Note Issue Date 0696 APPLICATION NOTE Phone Lines with Metasys Introduction Page 3 What is? *3 References *3
More informationIO Expansion Module User & Installation Manual
IO Expansion Module User & Installation Manual For FreeWave products: IOE-X-4422P IOE-X-4422PC December 10, 2009 1 User Manual Table of Contents Regulatory... 3 UL: Underwriters Laboratories... 3 General
More informationPart Number 129777-01 Revision A, January 1996. 3500 Monitoring System Rack Configuration and Utilities Guide
Part Number 129777-01 Revision A, January 1996 3500 Monitoring System Rack Configuration and Utilities Guide Copyright 1995 Bently Nevada Corporation All Rights Reserved. No part of this publication may
More informationEmail: tjohn@mail.nplindia.ernet.in
USE OF VIRTUAL INSTRUMENTS IN RADIO AND ATMOSPHERIC EXPERIMENTS P.N. VIJAYAKUMAR, THOMAS JOHN AND S.C. GARG RADIO AND ATMOSPHERIC SCIENCE DIVISION, NATIONAL PHYSICAL LABORATORY, NEW DELHI 110012, INDIA
More informationRFS-805. Digital Modulator AV to COFDM. User Manual
RFS-805 Digital Modulator AV to COFDM User Manual 1. Purpose of use RFS-805 is a digital modulator designed for a processing audio and video signals into COFDM (DVB-T) multiplex. 2. Installation The connections
More information14.5GHZ 2.2KW CW GENERATOR. GKP 22KP 14.5GHz WR62 3x400V
14.5GHZ 2.2KW CW GENERATOR GKP 22KP 14.5GHz WR62 3x400V UTILIZATION OF GKP 22KP GENERATOR With its characteristics of power stability whatever the load, very fast response time at a pulse, low ripple,
More informationTI 313 (1.0 EN) d&b Remote network - Integration
TI 313 (1.0 EN) d&b Remote network - Integration 1. Introduction The d&b Remote network offers various options to configure, control and monitor a d&b sound reinforcement system. This can be done by either
More informationProduct Information S N O. Portable VIP protection CCTV & Alarm System 2
Product Information S N O Portable VIP protection CCTV & Alarm System 2 G O V E R N M E N T A L S E C U R I T Y S O L U T I VIP KIT Rapid Deployment VIP Protection Kit The VIP KIT has been designed to
More informationIntroduction: Implementation of the MVI56-MCM module for modbus communications:
Introduction: Implementation of the MVI56-MCM module for modbus communications: Initial configuration of the module should be done using the sample ladder file for the mvi56mcm module. This can be obtained
More informationAuxiliary equipment for communication with the EuroProt protective devices
Auxiliary equipment for communication with the EuroProt protective devices RS232 cable This cable is used to connect the RS232 connector located on the front panel of the EuroProt devices to the 9 pin
More informationTEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev.
TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL Microener - Copyright 2010 FW 2.2 Date 01.12.2008 Rev. 0 1. Generality 3 2. Introduction 3 3. Accessories and Options 3 4. Installation 3 5. Connection
More informationTechnical Manual. For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI
Technical Manual For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI Caller ID.com WHOZZ CALLING? POS 2 Caller ID Monitoring Unit Technical Manual For use with Caller ID signaling
More informationIstituto Nazionale di Fisica Nucleare Sez di Ferrara. -------------------- PAX PS Board User Manual ---------------
Istituto Nazionale di Fisica Nucleare Sez di Ferrara. -------------------- PAX PS Board User Manual --------------- Author: Roberto Malaguti Project by:. Angelo Cotta Ramusino, Roberto Malaguti Via Saragat
More informationDesigning VM2 Application Boards
Designing VM2 Application Boards This document lists some things to consider when designing a custom application board for the VM2 embedded controller. It is intended to complement the VM2 Datasheet. A
More informationZC-24DO CANopen I/O Module: 24 Digital Outputs
Z-PC Line EN ZC-24DO CANopen I/O Module: 24 Digital Outputs Installation Manual Contents: - General Specifications - Technical Specifications - Installation Rules - Electrical connections - DIP-switches
More informationVibration Monitoring System Adash 3600
" User's guide Application: Vibration Monitoring System Adash 3600! Vibration diagnostics, monitoring and protective on-line system! On-line vibration monitoring system of engines, fans, pumps, gearboxes,
More informationDesigning the Solution for Electrochemistry Potentiostat/Galvanostat І Battery Cycler І Fuel Cell Test Station +82-2-578-6516 І sales@wonatech.
ZIVE Electrochemical Workstations ZIVE SP2 Designing the Solution for Electrochemistry Potentiostat/Galvanostat І Battery Cycler І Fuel Cell Test Station +82-2-578-6516 І sales@wonatech.com www.wonatech.com
More informationDS1721 2-Wire Digital Thermometer and Thermostat
www.dalsemi.com FEATURES Temperature measurements require no external components with ±1 C accuracy Measures temperatures from -55 C to +125 C; Fahrenheit equivalent is -67 F to +257 F Temperature resolution
More informationSecureLinx Spider Duo Quick Start Guide
SecureLinx Spider Duo Quick Start Guide SecureLinx Spider Duo Quick Start Guide SecureLinx Spider Duo QUICK START GUIDE CONTENTS Overview... 2 What s In The Box... 3 Installation and Network Settings...
More informationLONGLINE QSFP+ SR4. Features. Applications. Description. Page 1 of 13
LONGLINE QSFP+ SR4 Features 4 channels full-duplex transceiver modules Transmission data rate up to 10.5Gbps per channel 4 channels 850nm VCSEL array 4 channels PIN photo detector array Low power consumption
More informationDevelop a Dallas 1-Wire Master Using the Z8F1680 Series of MCUs
Develop a Dallas 1-Wire Master Using the Z8F1680 Series of MCUs AN033101-0412 Abstract This describes how to interface the Dallas 1-Wire bus with Zilog s Z8F1680 Series of MCUs as master devices. The Z8F0880,
More informationPCAN-MicroMod Universal I/O Module with CAN Interface. User Manual. Document version 2.1.0 (2014-01-16)
PCAN-MicroMod Universal I/O Module with CAN Interface User Manual Document version 2.1.0 (2014-01-16) Products taken into account Product Name Part number Model PCAN-MicroMod IPEH-002080 with firmware
More informationDisplay Message on Notice Board using GSM
Advance in Electronic and Electric Engineering. ISSN 2231-1297, Volume 3, Number 7 (2013), pp. 827-832 Research India Publications http://www.ripublication.com/aeee.htm Display Message on Notice Board
More informationCommunication Setup Application Note
Communication Setup Application Note This Application Note describes how to install and set up communication between the inverter and the SolarEdge Monitoring Server. This document contains the following
More informationSL Series AC and DC Electronic Loads
SL Series AC and DC Electronic Loads Applications AC & DC Power Supply Testing Rechargeable batteries and chargers Fuel cell test - cells and stacks PFC circuit test Pulsed LED Test and Burn-in Laser Diode
More informationDVR-4TL/8TL/16TL Setup Guide
Package Content DVR-4TL/8TL/16TL Setup Guide Inspect the DVR s packaging. Make sure that the DVR-4TL/8TL/16TL is packed properly. Remove all items from the box and make sure it contains the following items.
More informationEA-200. http://world.casio.com/edu/ Technical Reference. Contents. Sampling... 2 Analog Sampling... 3 Memory... 3 Pulse Sampling...
E Contents EA-200 Technical Reference Sampling... 2 Analog Sampling... 3 Memory... 3 Pulse Sampling... 4 Command Tables... 5 Command 1: Channel Settings... 9 Command 3: Sampling and Trigger Settings...
More informationLTM-1338B. Plus Communications Manual
LTM-1338B Plus Communications Manual 2000. Best Power, Necedah, Wisconsin All rights reserved. Best Power The System Setup option from the Main Menu on the front panel is passwordprotected. The default
More informationIf an occupancy of room is zero, i.e. room is empty then light source will be switched off automatically
EE389 Electronic Design Lab Project Report, EE Dept, IIT Bombay, Nov 2009 Fully-automated control of lighting and security system of a Room Group No: D2 Bharat Bhushan (06d04026) Sravan
More informationSHDSL LAN EXTENDER H301A. User Manual
SHDSL LAN EXTENDER H301A User Manual Rev. 1.0 Yoda Communications, Inc. Yoda Communications, Inc. Address 2F, No. 3-1, Industry East Road IX, Science Based Industrial Park, HsinChu, Taiwan Tel 886-3-5632323
More informationMANUAL PC1000R INFO@APART-AUDIO.COM
MANUAL PC1000R INFO@APART-AUDIO.COM Features The APart PC1000R is a professional multisource CD/USB/SD card music player, equipped with balanced and unbalanced analog outputs, coaxial and optical digital
More informationMethode Electronics. DM-338-GG-XXXX Up to 120 Gbps CXP Passive Cable Assembly. www.methode.com
DM-338-GG-XXXX Up to 120 Gbps CXP Passive Cable Assembly Compliant with Infiniband Architecture Specification Annex 6 Hot-pluggable footprint Supports Serial ID (write protected) Robust Die Cast Housing
More informationTable 1 below is a complete list of MPTH commands with descriptions. Table 1 : MPTH Commands. Command Name Code Setting Value Description
MPTH: Commands Table 1 below is a complete list of MPTH commands with descriptions. Note: Commands are three bytes long, Command Start Byte (default is 128), Command Code, Setting value. Table 1 : MPTH
More informationGM1200E Interface Cable
GM00E Interface Cable SPK+ Mic Aud Ext PTT SPK/0 Ext Alrm RJ Plug PTT/0 Flat Tx Audio SCI Data In SCI Data Out Emerg/ NPD In Motorola Accessory Connector (rear view) 0 Ign Det Flat Rx Audio CTS SW B+ Hook
More informationPart Number Description Packages available
Features 3 digital I/O Serial Data output Connects directly to RF Modules Easy Enc / Dec Pairing Function Minimal External Components Required Performs all encoding/decoding of data for Reliable Operation.
More information