CSDPR. Multi Powered Over-Current Relay

Size: px
Start display at page:

Download "CSDPR. Multi Powered Over-Current Relay"

Transcription

1 CSDPR Multi Powered Over-Current Relay

2 Index 1 Introduction 2 Design 2.1 Analog Input 2.2 Front Panel 2.3 Keypads 2.4 Battery Power Key 2.5 LEDs 2.6 Fault Recording 2.7 Trip Output 2.8 Assignment of the Output Relays 2.9 Potential input 3 Communication 3.1 RS 485 Communication 3.2 Front USB Communication 4 Protection Function 5 Battery Pack 6 Terminal Detail 7 Technical Data 7.1 Measuring Input 7.2 General Data 7.3 Communication Front Port RS Rear Port RS Setting Ranges and Steps 7.5 Voltage rating of Digital Input 7.6 Accuracy 7.7 Tripping Characteristics 7.8 Output Contacts Rating 7.9 Certified Type Test 8 Dimensional Drawing 9 Order Form 2

3 1. Introduction The numeric multi powered Over-current Relay CSDPR is a universal protection device specially designed for ring main units & feeder protection. It combines the following functions in one unit: Relay get energize either from Current,Aux. Voltage, front USB, Solar module or internal battery (whichever is available) O/C, S/C, E/F and E/F High Set protection DEFT and Inverse characteristics for O/C and E/F, individually selected for phase and earth fault Unbalance/ Asymmetric Protection Potential pulse output for direct triggering the circuit breaker with potential free alarm contacts. Remote Trip & Remote Protection Block input DI RS485-Modbus communication rear panel USB port for VIS (Virtual Injection System) Circuit breaker failure protection(50bf) Wide operating ranges of the auxiliary supply voltage (AC/DC) Last 5 Fault Record with Time stamp Solar Power Module Interface Digital filtering of measured quantities by using discrete Fourier analysis to suppress harmonics/dc/inrush Trip Counter for Breaker 2. Design Relay will get energized from any of the following available sources 1. Aux. Supply 2. CT Current 3. Internal Battery 4. USB Port 5. Solar cells Relay will operate its trip contacts only when CT current is present or Aux. Supply is available, with other power sources the relay can only edit & view the parameters & records. In the absence of Aux/Battery voltage/usb/solar panel relay will get energized if CT current in single phase is at least 20% of rated current. [This is not true for Neutral CT, minimum required current must flow in phase]. In case of three phases, relay will get energize from 15% of rated current. The Solar-Powered Relay: CSDPR can be energized from small 6V/0.5W solar panel. It will not only save the battery but also keep energize the relay like an auxiliary/battery powered relay. (Solar module plate is not the part of supply). 2.1 Analog Input The analog input signal of the conductor currents as per the terminal detail section 7.3, are fed to the protective device via separate input transformers. The continuously measured current values are galvanically isolated, analog & digitally filtered and finally fed to the analog/digital converter to get the True RMS value. 2.2 Front Panel The front panel of the protective device CSDPR comprises the following operation and indication elements: LCD ( 16 x 2) with Bright -Light Keypad with 5 keys: For setting of the parameters of the relay. Power On & off key to energize the relay from Battery 10 LEDs for fault annunciation Front Battery cover to replace battery. 2.3 Keypads The front panel keypad consists of five soft-touch keys. These keys are marked as RESET/E, +, - > and <. The RESET/E key provides reset function to the relay & act as Enter key for MMI. The keys marked? and? are meant for backward and forward scrolling respectively. The keys marked + and - are used for incrementing and decrementing selected parameter value. 2.4 Battery Power Key Middle key is the Battery Power On key to energize the relay with battery. Press of BAT.OFF key will switch off the battery power supply or relay will get automatically switch off after 15sec if keys are inactive, to save the battery life. 2.5 LEDs There are 10 LEDs on the front panel. Their functions are indicated by the appropriate inscriptions along with them. All LEDs are with Memory backup & they will maintain the previous status until fault is acknowledged through manual reset. The working is equivalent to a digital flag. Blinking of these LEDs indicates the pickup of element & steady state indicates the trip. 2.6 Fault Recording CSDPR records last 5 Faults. In Fault, it saves following information Value at Fault : L1, L2, L3, E in Amps Type of fault : SC: / OL / U0 Time Stamp : HH:MM:Sec Date Stamp : DD:MM:YY Fault recording is only possible with Aux. Supply/CT Current/Internal Battery Power/USB Powered 3

4 2.7 Trip Output In presence of Aux Supply: 4 Potential Free Contacts and 1 Potential O/P (24V/12V@0.2jouls /50msec ON Pulse). Duty Cycle will depend upon the strength of available current. In presence of only adequate CT current: 1 Potential Free Latch Contact and 1 Potential O/P (24V/12V@0.2jouls / /50msec ON Pulse). Duty Cycle will depend upon the strength of available current. Average 20% of the rated current must required in the phase to trip the breaker. 2.8 Assignment of the Output Relays CSDPR has four output relays. One latch relay is available in all models(except V1.0). Three extra programmable output relays available only in Auxiliary supply model. Relay reset operation can be configurable in automatic reset or manual reset mode from MMI. In automatic reset mode relay will be reset after the current goes below the pick-up level. In manual mode relay will be reset by pressing reset button. *Auto/Manual option is not applicable for Latch Relay. 2.9 Potential Input Two Potential DIs are available for control. DI 1 : Remote Block for 50/50N/51/51N & Unbalance Protection DI 2 : Direct Remote Trip DIs work only in case of Aux. Supply. DI_1 : Blocking the Protection Functions When this input, becomes high it will block the selected protections such as OL/SC /Earth/Earth-high set/u0. The selection of protections for blocking is done from MMI. Blocking will remain active till the potential is available on DI terminal. When DI 1 is low no protection will be blocked. DI_2: Direct Remote Trip In energized condition, irrespective of any pickup or fault user can trip the Circuit breaker, by applying voltage to Remote trip DI. 4. Protection CSDPR offers 50/51/ 50N /51N/ Unbalance/CBFP protections. Overcurrent Characteristic : DEFT / VINV /EINV / NINV Unbalance Protection(46): This is provided by the relay tripping in phase unbalance greater than setting % difference in terms of maximum phase current Tib: [(IMAX- IMIN)/ IMAX] 100[%] Circuit Breaker Failure Protection to CBFP The C.B. failure protection is based on supervision of phase current during tripping events. This protective function becomes active only after tripping. The criteria is whether all phase currents are dropped to <5% x In within set time of tcbfp. If not, then CB failure is detected and the assigned relay is activated. Annunication relay for CBFP only manually reset. Trip counter CSDPR includes on inbuilt CB trip counter which gets incremented after every trip of breaker. it goes maximum up to counts and after that it get reset and after that it get reset to zero again. It can reset through MMI. 5. Battery Pack CSDPR can be powered from battery & it requires 4 AA battery cell. Battery pack is replaceable from front panel. Battery will energize the relay, so that relay can even work in absence of auxiliary supply / CT current or solar power. Under power saving mode, Battery power will get automatically OFF, if no key is pressed for 15sec or press the OFF key. CSDPR requires 4 no of standard AA cell in its battery bank. Life of the battery depends on hour of usage & battery-ah. Li /Ni-Cd chargeable /non-chargeable battery of AA size is acceptable. Note: CSDPR will not charge the battery 3. Communication 3.1 RS485 Communication The CSDPR includes an RS485 communication on rear port.this port is available for MODBUS protocol. CSDPR relay has feature to transmit the data such as settings, measurements and faults to the SCADA system. For this communication auxiliary supply is required. A communication failure dose not affects protection function. 3.2 USB Front Communication The front USB Communication port is designed for VIS- Injection System for which the front end Software is provided. The S/w has features of testing the relay,retrieving the records and changing the settings. Note: Relay is plug & play on USB port. It automatically get energizes from USB port itself. 4

5 6. Terminal Detail The following shows the terminals back of CSDPR Terminal Name L1-L3 (S1-S2) Earth (S1-S2) RS485(P1 N1) AI -1 AI-C AI-2 Aux-P-Aux-N MHT(+) MHT(-) SM(+) SM(-) RLY1 (NO-COMM) *RLY-2/3/4 (NO-COMM) (available in Auxiliary model only) Terminal Description CT Terminal for Phase Current Inputs L1,L2,L3 CT Terminal for Earth Current Input RS485 Modbus Terminal ( P1- N1) (* feature available as per selected model) Analog Input for Remote Trip Analog Input Common for AI-1&2 Analog Input for Remote Block Auxiliary Supply for CSDPR (* feature available as per selected model) Pulse Output for Magnetic Hold Trip Coil of Breaker Solar Module Interface (* feature available as per selected model) Relay 1 Common for all faults with NO Latch contacts Relay 2-4 assignable relays with NO contacts *available in Auxiliary model only 5

6 7. Technical Data 7.1 Measuring Input Rated data Rated current IN :1A Burden : 1A Frequency: 50 Hz Thermal load capacity: Continuously : 2 x In 1s 20 x In Dropout Ratio : > 95% 7.2 General Data Rated auxiliary voltage UH Universal 24 VAC to 260 VAC 24 VDC to 360 VDC Rated supply for digital input Normal Voltage UN VAC Power consumption of Aux supply Quiescent approx. 3W Operating appx 6W Dropout ratio > 95 % Reset Returning time 30 ms 7.3 Communication Front Port (USB) Front Port CSE protocol with VIS-LINK on USB Cable Type A/A Rear port protocol Rear port protocol Baud rate Parity Stop Bit Data Bit Slave Address MODBUS RTU 2400,4800,9600,19200 (Editable) NONE,EVEN,ODD (Editable) 1 bit 8 bit data 1-32(Editable) Solar Module Interface for Solar Module Interface: SM+ /SM- Terminal Input voltage : 6V-35V DC Input range Suitable with 6V/0.5W Solar panel 7.4 DO Assignment Parameter Display Detail DO assignment for Phase 1st stage Overload OL_RELAY RLY2, RLY3, RLY4 DO assignment for Phase 2nd Stage Overload SC_RELAY RLY2, RLY3, RLY4 DO assignment for Earth 1st stage Overload E_RELAY RLY2, RLY3, RLY4 DO assignment for Earth 2nd Stage Overload EH_RELAY RLY2, RLY3, RLY4 DO assignment for Self Supervision SupV_RY RLY2, RLY3, RLY4 DO assignment for CBFP CBFP_RY RLY2, RLY3, RLY4 DO assignment for Unbalance U0_RY RLY2, RLY3, RLY4 6

7 7.5 DI Blocking for Protection Parameter Display Detail Relay assignment for Phase 1st stage Overload I> BLOCK / UNBLOCK Relay assignment for Phase 2nd Stage Overload I>> BLOCK / UNBLOCK Relay assignment for Earth 1st stage Overload Ie> BLOCK / UNBLOCK Relay assignment for Earth 2nd Stage Overload Ie>> BLOCK / UNBLOCK Relay assignment for Unbalance U0 BLOCK / UNBLOCK 7.6 Setting Ranges and Steps Parameter Display Setting range Step 1st Stage Phase Pickup I> x IN 0.05 x IN DEFT Trip Time for 1st stage Overload t > s 0.01 s Inverse TMS for 1st stage phase Overload ti > nd Stage Phase Pickup I >> x IN 0.5x IN 2nd Stage Phase Trip Time t >> s 0.01 s Earth Fault 1st Stage Pickup Ie > x IN 0.05x IN DEFT Trip Time for 1st stage Earth Fault te > s 0.01s Inverse TMS for 1st stage earth fault overload Tie nd Stage Earth Fault Pickup IE >> x IN 0.05 x IN 2nd Stage Earth Fault Trip Time tie >> s 0.01s Phase Unbalance Pickup U0 5-80% 1% Phase Unbalance Trip Time t sec 0.01s Enable CBFP Protection Enable YES / NO - CBFP Scan Time tcbf sec 0.1sec CT Ratio for Primary Current Display CT Ratio Mode of Tripping Trip Type MHT/RLY/DUAL Voltage Rating for Digital Input (DI1 & DI2) Operating Range: 80V-250V AC/DC (Non Polar with Common Terminal for both DI) 7.8 Accuracy Tripping times with prefault : Pickup Accuracy: +5% DMT: + 3% of the setting value+20msec IDMT: Accuracy as per IEC (2 x Is to 20 Is) For VINV / NINV: + 5% +20msec or + 30 msec (which ever is higher) For EINV : + 7.5%+20msec or + 30 msec (which ever is higher) For ( <.20 X Is) : + 7.5%+20msec or + 30 msec (which ever is higher) Tripping time without prefault Standard time+ Additional delay msec 7

8 7.9 Tripping characteristics (IEC or BS 142) 0.14/0.06 Normal Inverse 3.0/1.3 = ti [s] 0.02 (I / I S) 1 I: Injected Current Is: Pickup Set Level ti: TMS for Inverse Characteristic t: Definite delay in DEFT characteristic 13.5 Very Inverset = ti [s] (I / I S) 1 Extremely Inverset = ti [s] 80 2 (I / I S) - 1!!!!!! O/L, S/C, E and EH protections are available with DISABLE option in HMI Output Contact (relay specs) Number of relays : 4 Relay Contacts (RLY: 2,3,4) Configurable & available : Relay, 2, 3 and 4 are user programmable for I >, I >>, Ie only with Auxiliary supply model > and Ie >>,CBFP, Unbalance Relay Contacts :1 (Available in all models) Latch type of relay common for all protections Max. breaking capacity : 1250 VA / 150 W resistive 500 VA / 90 W inductive Max. breaking voltage : 400 V AC, 125 V DC Max. continuous AC current : 5 A Max. making current (16 ms) : 20 A 7.11 Certified Type Test Environmental conditions (Recommended Ambient temperature range) Operating Temperature Range: Continuous Withstand -25 to +60 C Limit(Note 1) -25 to +70 C. Storage Temperature Range: -25 to +70 C Note: The upper limit is permissible not for continuous period. Mechanical environment. Vibration Test : IEC , class 2. Shock: IEC , class 1. S.No Description of test Standard 1 Insulation test EC Dielectric test IEC KV impulse voltage test IEC High freq interference test severity class 3 IEC Radio interference suppression test EN55011 cl Radio interference suppression test EN55011 cl Radiated radio freq electromagnetic IEC field immunity test 8 Conductive RF immunity test ENV Surge immunity EN ESD test severity class 3 EN Fast transient disturbance test IEC Power frequency magnetic Field immunity test IEC

9 8. Dimensional Details Side View Back View Front View 9

10 8. Dimensional Details -x- -x- -x- -x- Potential O/P Pulse 2 1 With Aux. Supply Without Aux. Supply --- Communication : Modbus(RS-485) Without Communication --- With Solar Interface option CSDPR -V1- -A- -C- -S- Without Solar Interface option --- For Example: CSDPR-V1-2ACS 10

11 CSDPR For further information, please contact: C&S Electric Ltd. (Protection & Control Division) 44, Okhla Industrial Estate, Phase -III, New Delhi (INDIA) Phone : , /54/64 Fax: cspc@cselectric.co.in Branch office Branch Phone Fax Issue Date : Rev. Date : Rev. No : 00 Ahmedabad: /35/ cspc.ahmedabad@cselectric.co.in Bangalore: /73, cspc.bangalore@cselectric.co.in Bhubaneswar: cspc.bhubaneswar@cselectric.co.in Chennai: cspc.chennai@cselectric.co.in Cochin: cspc.cochin@cselectric.co.in Delhi: cspc.delhi@cselectric.co.in Hyderabad: / cspc.hyderabad@cselectric.co.in Kolkata: / cspc.kolkata@cselectric.co.in Mumbai: /47/ cspc.mumbai@cselectric.co.in Pune: / cspc.pune@cselectric.co.in

Trip circuit supervision relay. Type RXTCS

Trip circuit supervision relay. Type RXTCS Trip circuit supervision relay Type RXTCS ABB a global technology leader ABB is a global leader in Power and Automation technologies that enable utility and industry customers to improve performance while

More information

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display

More information

Voltage Regulator SPAU 341 C. Product Guide

Voltage Regulator SPAU 341 C. Product Guide Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations

More information

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features: Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays

More information

Current and voltage measuring relays

Current and voltage measuring relays Current and voltage measuring relays RXIK 1, RXEEB 1 and Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice RXIK 1 RXEEB 1 (SE980082) (SE980081) (SE970869) Features Application

More information

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation

More information

Quick Connect. quick - simple - efficient. www.g-mw.de

Quick Connect. quick - simple - efficient. www.g-mw.de Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power

More information

Disturbance Recoder SPCR 8C27. Product Guide

Disturbance Recoder SPCR 8C27. Product Guide Issued: April 1999 Status: Updated Version: C/26.04.2006 Data subject to change without notice Features Versatile digital disturbance recorder module for recording various phenomena in the electric power

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical

More information

Capacitor Protection Relay SPAJ 160 C. Product Guide

Capacitor Protection Relay SPAJ 160 C. Product Guide Issued: April 1999 Status: Updated Version: C/19.04.2006 Data subject to change without notice Features One-, two- and three-phase overload stage with definite time characteristic One-, two- and three-phase

More information

Generator Differential Relay Electrical Apparatus

Generator Differential Relay Electrical Apparatus Generator Differential Relay Electrical Apparatus MD3G Rotating Machine Differential Relay 150-3 The MD3G Rotating Machine Differential Relay is a member of Cooper Power Systems Edison line of microprocessor

More information

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.

More information

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Bulletin 150 SMC Flex Smart Motor Controller Specifications Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering

More information

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800 Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement

More information

Energy Management Energy Meter Type EM23 DIN

Energy Management Energy Meter Type EM23 DIN Energy Management Energy Meter Type EM23 DIN Class 1 (kwh) according to EN62053-21 Class B (kwh) according to EN50470-3 Class 2 (kvarh) according to EN62053-23 Accuracy ±0.5 RDG (current/voltage) Energy

More information

Circulating Current Relay. Type IRXm

Circulating Current Relay. Type IRXm Circulating Current Relay Type IRXm ABB a global technology leader ABB is a global leader in Power and Automation technologies that enable utility and industry customers to improve performance while lowering

More information

Telephone- and leased line modem for industrial applications TD-36

Telephone- and leased line modem for industrial applications TD-36 Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased

More information

Relion 605 series. Self-powered feeder protection REJ603 Product Guide

Relion 605 series. Self-powered feeder protection REJ603 Product Guide Relion 605 series Relion 605 series Relion 605 series Self-powered feeder protection Product Guide Product version: 3.0 Contents 1.... 3 2. Relay functions... 3 3. Protection functions... 4 4. Application...

More information

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY 2 TRACTION NETWORK MONITORING AND PROTECTION SYSTEM Traction network monitoring and protection system,

More information

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6. 38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC

More information

Rack mounted telephone- and leased line modem for industrial applications

Rack mounted telephone- and leased line modem for industrial applications Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as

More information

PCS0100en 02.2008. Persy Control Services B.V. Netherlands

PCS0100en 02.2008. Persy Control Services B.V. Netherlands P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for

More information

NC-12 Modbus Application

NC-12 Modbus Application NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1

More information

User Manual V1.0 2014 SDM220MODBUS. Single-Phase Two Module DIN rail Meters

User Manual V1.0 2014 SDM220MODBUS. Single-Phase Two Module DIN rail Meters SDM220MODBUS Single-Phase Two Module DIN rail Meters Measures kwh, Kvarh, KW, Kvar, KVA, PF, Hz, dmd, V, A, etc. Di-directional measurement IMP & EXP Two pulse outputs RS485 Modbus Din rail mounting 36mm

More information

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D 7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values

More information

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of

More information

Safety technique. Emergency stop module BO 5988 safemaster

Safety technique. Emergency stop module BO 5988 safemaster Safety technique Emergency stop module BO 5988 safemaster 0221562 Function diagram Pushbutton on Mains or emergencystop () K1 According to EC Directive for machines 98/37/EG According to IEC/E 60204-1

More information

Eaton s E-Series protective relay family

Eaton s E-Series protective relay family E-Series protective relays Feeder distribution relays Motor relays Transformer relays Generator relays Eaton s E-Series protective relay family Microprocessor-based design Eaton s E-Series relay family

More information

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A AUTOMATIC TRANSFER SWITCH Changeover Type from 250A to 2500A Table of Contents Preamble 1.1 Theoretical base 1.2 Selection the size of automatic transfer switch 1.3 Automatic transfer switch components

More information

Power Meter Series 700

Power Meter Series 700 PowerLogic power-monitoring units Power Meter Series 700 Technical data sheet 2007 Functions and characteristics E90463 The PowerLogic Power Meter Series 700 offers all the measurement capabilities required

More information

Application/Connection Examples

Application/Connection Examples This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

ELR: ABB range of front panel residual current relays Protection device according to IEC/EN 60947-2 Annex M

ELR: ABB range of front panel residual current relays Protection device according to IEC/EN 60947-2 Annex M ELR: ABB range of front panel residual current relays Protection device according to IEC/EN 60947-2 Annex M Tested, certified, reliable Network monitoring and protection The electronic residual current

More information

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out APC Matrix-UPS, 3750 Watts / 5000 VA,Input 208V / Output 120V, 208V, Interface Port DB-9 RS-232, SmartSlot, Extended runtime model Includes: CD with software,

More information

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications.

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592. * see variants. Applications. Safety Technique SAFEMASTER Emergency Stop Module BG 5924, IP 5924 Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start 0225592 BG 5924 IP 5924 Product Description

More information

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils

More information

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in Single or Dual loop detector Automatically adjustment of detection level Manual sensitivity for compensations of variations Easy installation

More information

Auxiliary Relay. Type P8n, PQ8n, PN8n

Auxiliary Relay. Type P8n, PQ8n, PN8n Auxiliary Relay Type P8n, PQ8n, PN8n ABB a global technology leader ABB is a global leader in Power and Automation technologies that enable utility and industry customers to improve performance while lowering

More information

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches PART 1 GENERAL 1.01 Scope Optional Standby Power Generator Systems A. Furnish and install automatic transfer switches

More information

ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL

ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL ALARM ANNUNCIATOR ME - 3010 INSTRUCTION MANUAL INTRODUCTION... 2.. TECHNICAL DATA... 3 ACCESSORIES... 5. INSTALLATION... 7 OPERATION... 12. TECHNICAL INFORMATION... 13 MAINTENANCE... 14. CONFIGURATIONS...

More information

MHCO MHCO-RI. Transmitter The Transmitter, connected to the system, acquires the inputs and througth a fiber optic transmits it to the receiver.

MHCO MHCO-RI. Transmitter The Transmitter, connected to the system, acquires the inputs and througth a fiber optic transmits it to the receiver. -TVI -RI D.C. MEASURING CONVERTER Converter for D.C. Current and/or Voltage measurement. Direct connection to D.C. mains rating up to 4 kvcc. Fully isolated multi-voltage power suppy. Fiber optic connection

More information

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications 077 Series Analogue Features Monitors and controls any variable which can be converted to an A.C. or D.C. signal. Rugged, shock and vibration resistant design Indicator, relays and power unit in one housing

More information

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

RM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage

More information

DC UPS. RTB.e 50-1000 A. IMB.e/ITB.e 5-200 kva. E2001.e/E3001.e 5-200 kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

DC UPS. RTB.e 50-1000 A. IMB.e/ITB.e 5-200 kva. E2001.e/E3001.e 5-200 kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB. Oil & Gas Energy Catalogue DC UPS RTB.e 50-1000 A 3 phase rectifier battery chargers voltage: 400 Vac, 3-phase, 50/60 Hz voltage: 24/48/110/220 Vdc RMB.e/RCB.e 50-100-150 A 1 and 3 phase compact rectifier

More information

Reyrolle Protection Devices. 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy

Reyrolle Protection Devices. 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy Reyrolle Protection Devices 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy Siemens Protection Devices Limited 2 7PG17 XR101 & XR102 Intertripping Relay

More information

Energy Management Power Analyzer Type WM14-96 Basic Version

Energy Management Power Analyzer Type WM14-96 Basic Version Energy Management Power Analyzer Type WM-96 Basic Version Optional dual pulse output Alarms (visual only) V, An Optional galvanically insulated measuring inputs Product Description 3-phase power analyzer

More information

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH Cat transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a

More information

Three-phase monitoring relay CM-PFE

Three-phase monitoring relay CM-PFE Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics

More information

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE for solar energy management LEATEC Delivering Solutions for Energy Management SOLAR ENERGY DATA CENTER BUILDING 4 to8 String Monitoring with 0.% Accuracy

More information

OVERCURRENT & EARTH FAULT RELAYS. To study the protection of equipment and system by relays in conjunction with switchgear.

OVERCURRENT & EARTH FAULT RELAYS. To study the protection of equipment and system by relays in conjunction with switchgear. OVERCURRENT & EARTH FAULT RELAYS Objective: To study the protection of equipment and system by relays in conjunction with switchgear. Theory: The function of a relay is to detect abnormal conditions in

More information

Electrical Safety Tester

Electrical Safety Tester Electrical Safety Tester GPT-9000 Series QUICK START GUIDE GW INSTEK PART NO. 82PT-99040MA1 ISO-9001 CERTIFIED MANUFACTURER This manual contains proprietary information, which is protected by copyright.

More information

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application. 1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay

More information

INSTRUCTION MANUAL FOR. MC31A DUAL RATED CT 3 Phase Over Current and Earth Fault Relay

INSTRUCTION MANUAL FOR. MC31A DUAL RATED CT 3 Phase Over Current and Earth Fault Relay INSTRUCTION MANUAL FOR MC31A DUAL RATED CT 3 Phase Over Current and Earth Fault Relay CONTENTS Description Page No. 1. Introduction 1 2. General characteristics 2.1 Non volatile Memory 1 2.2 Auxiliary

More information

Uninterruptible Power Supply

Uninterruptible Power Supply 96-01101 / rev. 2e / 2-2-12 Uninterruptible Power Supply EXCEPTIONAL SUPPORT & PROTECTION Uninterruptible Power Supply with Energy Saver design that is optimized to address the needs of A/V systems Features

More information

48 SERIES Relay interface modules 10 A

48 SERIES Relay interface modules 10 A 48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply

More information

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware Substation Automation Products Relion 670/650 series IEC and ANSI Hardware ABB Group 1MRG014097 October 2013 Relion 670/650 series hardware Contents Relion 670/650 series Relion Hardware Relion Common

More information

Permissible ambient temperature Operation Storage, transport

Permissible ambient temperature Operation Storage, transport The Sitras PRO combined DC protective unit and controller is used in the power supply for DC railways in mass transit and main-line systems up 3,000 V DC. It protects DC switch gear and contact line systems

More information

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

60 Series - General purpose relays 6-10 A. Features 60.12 60.13

60 Series - General purpose relays 6-10 A. Features 60.12 60.13 Features 60.12 60.13 Plug-in mount 10 A General purpose relay 2 & 3 pole changeover contacts Cadmium Free contacts (preferred version) AC coils & DC coils UL Listing (certain relay/socket combinations)

More information

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Control Devices Catalogue. Control Devices. Preferred and Standard Products Control Devices Catalogue Control Devices Preferred and Standard Products KOP.J Timer Electronic 22.5 mm Characteristics Mounting KOP.J 22.5 mm mono or multifunction high immunity to interference surface

More information

Duct Humidity Transmitter

Duct Humidity Transmitter SDC-H Duct Humidity Transmitter Features Replaceable sensor element Humidity measurement for air ducts Minimum and maximum value memory 0 0V, 0 0mA or 0V, 4 0mA measuring signals selectable with jumpers

More information

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Automation System TROVIS 6400 TROVIS 6493 Compact Controller Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general

More information

Combined overcurrent & earth-fault relay. Type SPAJ 140 C

Combined overcurrent & earth-fault relay. Type SPAJ 140 C Combined overcurrent & earth-fault relay Type SPAJ 140 C ABB a global technology leader ABB is a global leader in Power and Automation technologies that enable utility and industry customers to improve

More information

Softstarters. Type PSTX Fieldbus communication, Built-in Modbus RTU. 1SFC132089M0201 April 2015 1SFC132089M0201 1

Softstarters. Type PSTX Fieldbus communication, Built-in Modbus RTU. 1SFC132089M0201 April 2015 1SFC132089M0201 1 Softstarters Type PSTX Fieldbus communication, Built-in Modbus RTU 1SFC132089M0201 April 2015 1SFC132089M0201 1 1 Modbus RTU The Modbus protocol is a fieldbus protocol that provides full control and status

More information

AC3200 INTELLIGENT BROADBAND AMPLIFIER

AC3200 INTELLIGENT BROADBAND AMPLIFIER Kari Mäki 9.4.2013 1(7) AC3200 INTELLIGENT BROADBAND AMPLIFIER AC3200 is the latest leading-edge addition to AC family with extended frequency and gain ranges and integrated electrical controls in both

More information

*.ppt 11/2/2009 12:48 PM 1

*.ppt 11/2/2009 12:48 PM 1 Digital Compressor Controller *.ppt 11/2/2009 12:48 PM 1 Copeland Scroll Digital Controller Simple Controller That Enables OEM s To Use Digital Scrolls Relieves OEM From Developing Special Controllers

More information

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems 3 072 RDJ10RF RCR10/433 Wireless room temperature controller with 24-hour time switch and LCD Programmable, for heating systems RDJ10RF/SET Operating modes: Automatic, Comfort, Energy Saving, and Frost

More information

Installation manual. Generator Paralleling Controller GPC multi-line 2 4189340225C

Installation manual. Generator Paralleling Controller GPC multi-line 2 4189340225C Installation manual Generator Paralleling Controller GPC multi-line 2 Software ver. 1.3X Compact system in one unit - dynamic synchronisation - load sharing - generator protection DEIF A/S 3-phase AC RMS

More information

E-Series protective relay family

E-Series protective relay family E-Series protective relays Feeder distribution relays Motor relays Transformer relays Generator relays E-Series protective relay family Reliable protection for every application Eaton s E-Series relay

More information

Polyphase kwh Electricity Meter

Polyphase kwh Electricity Meter Polyphase kwh Electricity Meter Model Type: 5192B USER MANUAL Issue 1.0 E & O E AMPY Automation Ltd. July 2003 doc. ref. CSD 093 Contents 1 Introduction 2 1.1 Purpose 2 2 Definitions 2 2.1 References 2

More information

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF65, EF96 and EF146 Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays.

More information

80 Series - Modular timers 16 A. Features 80.01 80.11

80 Series - Modular timers 16 A. Features 80.01 80.11 80 Series - Modular timers 16 A Features 80.11 Multi-function and mono-function timer range - Multi-function & multi-voltage 80.11 - On-delay, multi-voltage 17.5 mm wide Six time scales from 0.1s to 24h

More information

THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit 55-77-03-62, March 2012

THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit 55-77-03-62, March 2012 Technical Information THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit 55-77-03-62, March 2012 GENERAL DESCRIPTION THYRISTORS T1-1PH is a full digital and universal

More information

M2M The measure of efficiency

M2M The measure of efficiency M2M The measure of efficiency The importance of control Measurement and advanced analysis of electrical parameters To make equipment as efficient as possible, it is essential to know the details of its

More information

Preset Counter signo 721

Preset Counter signo 721 Most simple handling Impressive, clearly readable display in 48x48 mm Input frequency up to 60 khz Easy installation due to pluggable terminals TECHNICAL DATA GENERAL Display Height of digits Supply voltage

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

TURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES

TURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES SED-635 Digital Excitation System SED-635 is a complete excitation system capable of adapting to control synchronous generators of any size. The integration of the TOUCH SCREEN operator interface and a

More information

T 3000. Substation Maintenance and Commissioning Test Equipment

T 3000. Substation Maintenance and Commissioning Test Equipment T 3000 Substation Maintenance and Commissioning Test Equipment Multi function system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy

More information

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters

RM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main

More information

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell Data, installation, operation and maintenance 4 & 8 Zone Fire Panels Zircon range BARDIC by Honeywell LED flashing LED Continuous FAULT DISABLE/TEST Power General Fault Sounder Fault/ Disable System Fault

More information

Applications. diris_826_a_1_gb_cat

Applications. diris_826_a_1_gb_cat Measurement units NEW diris_824_a_1_cat Energy monitoring and management of low voltage/ high voltage electrical installations Function are measurement units which can provide all the functions offered

More information

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA w VOLTAGE MONITORING RELAY UR5U1011 w SCHRACK-INFO AC/DC voltage monitoring in 1-phase mains Undervoltage monitoring 1 change over contact Width 17.5 mm Installation design w TECHNICAL DATA 502 1. Functions

More information

Siemens Integrated Substation Condition Monitoring System. Circuit Breaker Monitoring

Siemens Integrated Substation Condition Monitoring System. Circuit Breaker Monitoring Siemens Integrated Substation Condition Monitoring System Circuit Breaker Monitoring System Description Introduction The Circuit Breaker Monitor [CBM] is only one example of the way that the Substation

More information

mecotron Safety relay ESTOP-2 For emergency stop monitoring

mecotron Safety relay ESTOP-2 For emergency stop monitoring E0006 000824 Safety relay E-2 For emergency stop monitoring Description The safety module E-2 for emergency stop monitoring is used for safety breaking one or more circuits and is designed to be incorporated

More information

MasterINTERFACE 39 Series - Relay interface modules

MasterINTERFACE 39 Series - Relay interface modules MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy

More information

Remote Monitoring and REC 501 Control Unit Product Guide

Remote Monitoring and REC 501 Control Unit Product Guide Remote Monitoring and Control Unit REC 501 Product Guide Issued: May 1999 Status: Updated Version: B/06.11.2001 Data subject to change without notice Features Remote control and monitoring unit for the

More information

Generator Stator Protection, under/over voltage, under /over frequency and unbalanced loading. Ramandeep Kaur Aujla S.NO 250447392

Generator Stator Protection, under/over voltage, under /over frequency and unbalanced loading. Ramandeep Kaur Aujla S.NO 250447392 1 Generator Stator Protection, under/over voltage, under /over frequency and unbalanced loading By Ramandeep Kaur Aujla S.NO 250447392 ES 586b: Theory and applications of protective relays Department of

More information

Pluggable interface relays CR-P Pcb relays

Pluggable interface relays CR-P Pcb relays 2CDC 293 034 F0004 1 2 4 3 Features 9 different supply s: DC versions: 12 V, 24 V, 48 V, 110 V AC versions: 24 V, 48 V, 110 V, 120 V, 230 V Output contacts: 1 c/o (16 A) or 2 c/o (8 A) Cadmium-free contact

More information

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay

More information

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu, APPROVAL SHEET CUSTOMER ituner CUSTOMER P/N DESCRIPTION EDAC MODEL 12V/6.6A SERIES NO. (E17) EA10953A DATE 2010-06-22 REVISION 0 APPROVED DESIGN PREPARE RoHS CONCLUSION APPROVED CONDITON CUSTOMER S APP

More information

DC Electronic Loads 8500 series

DC Electronic Loads 8500 series Data Sheet DC Electronic Loads 8500 series 2400W 600 W - 1200 W 300 W Versatile & Economical DC Electronic Loads The 8500 series Programmable DC Electronic Loads can be used for testing and evaluating

More information

CONSTANT CURRENT REGULATOR INDUPERM TYPE CCR 951. Standarddescription of CONSTANT CURRENT REGULATOR TYPE CCR 951.

CONSTANT CURRENT REGULATOR INDUPERM TYPE CCR 951. Standarddescription of CONSTANT CURRENT REGULATOR TYPE CCR 951. Standarddescription of TYPE CCR 951 List of contents: A. General Description B. General Data's and Functions C. CCR Working Principle D. Specifications Page 1 of 9 pages A. General Description. Induperm

More information

Waveguide Access Point WGA631. Product Guide

Waveguide Access Point WGA631. Product Guide Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................

More information

Programming Logic controllers

Programming Logic controllers Programming Logic controllers Programmable Logic Controller (PLC) is a microprocessor based system that uses programmable memory to store instructions and implement functions such as logic, sequencing,

More information

PNOZsigma - Base units

PNOZsigma - Base units PNOZsigma - Base units Register Login Sensors Control and Communication Electronic monitoring relays Safety Relays PNOZ X PNOZsigma PNOZelog PNOZmulti PNOZpower Configurable control systems Programmable

More information

Electronic overload relay EF19 and EF45

Electronic overload relay EF19 and EF45 Data sheet Electronic overload relay EF19 and EF45 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

Data Bulletin. Choosing a Trip Unit for PowerPact H-, J-, and L-Frame Circuit Breakers. Introduction. Thermal-Magnetic or Electronic Trip Unit?

Data Bulletin. Choosing a Trip Unit for PowerPact H-, J-, and L-Frame Circuit Breakers. Introduction. Thermal-Magnetic or Electronic Trip Unit? Data Bulletin 011DB110 07/01 Choosing a Trip Unit for PowerPact H-, J-, and L-Frame Circuit Breakers ENGLISH Inoduction Thermal-Magnetic or Eleconic Trip Unit? Thermal-Magnetic Trip Units 01171 t 0119

More information