HEAT Endpoint Management and Security Suite 8.4. Server Install Guide
|
|
|
- Lester Jacobs
- 9 years ago
- Views:
Transcription
1 8.4 Server Install Guide
2 - 2 -
3 Notices Version Information Server Install Guide; - HEAT Endpoint Management and Security Suite Version Published: May 2016 Document Number: 02_202_8.4_ Copyright Information Lumension Security Inc., 8660 East Hartford Drive, Suite 300 Scottsdale, AZ Phone: Fax: [email protected] Copyright ; Lumension Security, Inc.; all rights reserved. Covered by one or more of U.S. Patent Nos. 6,990,660, 7,278,158, 7,487,495, 7,823,147, 7,870,606, and/or 7,894,514; other patents pending. This manual, as well as the software described in it, is furnished under license. No part of this manual may be reproduced, stored in a retrieval system, or transmitted in any form electronic, mechanical, recording, or otherwise except as permitted by such license. LIMITATION OF LIABILITY/DISCLAIMER OF WARRANTY: LUMENSION SECURITY, INC. (LUMENSION) MAKES NO REPRESENTATIONS OR WARRANTIES WITH REGARD TO THE ACCURACY OR COMPLETENESS OF THE INFORMATION PROVIDED IN THIS MANUAL. LUMENSION RESERVES THE RIGHT TO MAKE CHANGES TO THE INFORMATION DESCRIBED IN THIS MANUAL AT ANY TIME WITHOUT NOTICE AND WITHOUT OBLIGATION TO NOTIFY ANY PERSON OF SUCH CHANGES. THE INFORMATION PROVIDED IN THIS MANUAL IS PROVIDED AS IS AND WITHOUT WARRANTY OF ANY KIND, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. THE INFORMATION PROVIDED IN THIS MANUAL IS NOT GUARANTEED OR WARRANTED TO PRODUCE ANY PARTICULAR RESULT, AND THE ADVICE AND STRATEGIES CONTAINED MAY NOT BE SUITABLE FOR EVERY ORGANIZATION. NO WARRANTY MAY BE CREATED OR EXTENDED WITH RESPECT TO THIS MANUAL BY SALES REPRESENTATIVES OR WRITTEN SALES MATERIALS. LUMENSION SHALL NOT BE LIABLE TO ANY PERSON WHATSOEVER FOR ANY LOSS OF PROFIT OR DATA OR ANY OTHER DAMAGES ARISING FROM THE USE OF THIS MANUAL, INCLUDING BUT NOT LIMITED TO DIRECT, INDIRECT, SPECIAL, INCIDENTAL, CONSEQUENTIAL, OR OTHER DAMAGES
4 Trademark Information Lumension, Lumension Endpoint Management and Security Suite, Lumension Endpoint Management Platform, Lumension Patch and Remediation, Lumension Enterprise Reporting, Lumension Security Configuration Management, Lumension Content Wizard, Lumension AntiVirus, Lumension Wake on LAN, Lumension Power Management, Lumension Application Control, Lumension Device Control, Lumension Endpoint Security, Lumension Intelligent Whitelisting, PatchLink, PatchLink Update, their associated logos, and all other Lumension trademarks and trade names used here are the property of Lumension Security, Inc. or its affiliates in the U.S. and other countries. RSA Secured is a registered trademark of RSA Security Inc. Apache is a trademark of the Apache Software Foundation. In addition, any other companies' names, trade names, trademarks, and products mentioned in this document may be either registered trademarks or trademarks of their respective owners. Feedback Your feedback lets us know if we are meeting your documentation needs. the HEAT Software Technical Publications department at [email protected] to tell us what you like best, what you like least, and to report any inaccuracies
5 Table of Contents Table of Contents Preface: About This Document... 7 Typographical Conventions... 7 Contacting HEAT Software... 8 System Requirements... 9 Supported Operating Systems...9 Supported Languages and Locales...10 Software Requirements...11 Web Browser Requirements...12 SQL Server Requirements IIS Requirements NET Framework Requirements...15 Hardware Requirements...15 Network Requirements Recommended Configurations...17 Combined EMSS Application and Database Server...18 Separated EMSS Application and Database Servers Chapter 2: Installing Downloading EMSS...23 About SQL Server Instance Location Defining the Web Client Account and Service Account Selecting an Installation Method...25 Installing Using a New SQL Server Instance...26 Installing Using an Existing SQL Server Instance (Either Locally or Remotely) Installing Using a Remote SQL Server Instance (with no Local Instance) Installing (Separate EMSS and SQL Server Admins) Beginning Installation (Part I)...64 Creating Components on SQL Server (Part II) Completing Installation (Part III) Logging In to...78 Setting Up...79 Appendix A: Configuring Remote SQL Server Instances...83 Creating Remote Accounts Configuring SQL Server to Accept Remote Connections Configuring Windows Firewall for SQL Server Instance Access...88 Appendix B: Configuring Your Server to use SSL Configuring SSL Appendix C: Upgrading from Previous Installations Appendix D: Installation Checklist Server Installation Checklist
6 - 6 -
7 Preface About This Document This Server Install Guide is a resource written for all users of HEAT Endpoint Management and Security Suite 8.4. This document defines the concepts and procedures for installing, configuring, implementing, and using 8.4. Tip: HEAT documentation is updated on a regular basis. To acquire the latest version of this or any other published document, please refer to the HEAT Customer Portal ( Typographical Conventions The following conventions are used throughout this documentation to help you identify various information types. Table 1: Typographical Conventions Convention Usage bold Buttons, menu items, window and screen objects. bold italics Wizard names, window names, and page names. italics New terms, options, and variables. MONOSPACE UPPERCASE Keyboard keys. BOLD UPPERCASE SQL Commands. monospace File names, path names, programs, executables, command syntax, and property names
8 Contacting HEAT Software Arizona Ireland California 8660 East Hartford Drive Suite 300 Scottsdale, AZ United States of America HEAT Software Ireland Ltd. Citypoint Prospect Hill Galway City H91 P9KP Ireland 490 N. McCarthy Blvd. Suite 100 Milpitas, CA United States of America 490 N. McCarthy Blvd. Phone: Phone: Fax: Phone: Fax: Phone: Phone: HEAT Support phone: (USA) (USA - legacy Sanctuary products) (EMEA) (UK) +61 (02) (Australia) (Hong Kong) (Singapore) submit a ticket: Registered users can open a support ticket via the customer portal ( HEAT customers without a support account should contact our support team ([email protected]) to have an account created. Note: For additional contact information, please visit the Contact HEAT page at
9 System Requirements Before installing, verify that the targets meets hardware, software, and network requirements. On servers that do not meet recommended system requirements If your target server does not meet the system requirements, EMSS will not perform optimally, or may not install. Review all hardware, software, and network requirements before proceeding with installation. Supported Operating Systems The server is supported on a number of Microsoft Windows operating systems. Table 2: Supported Operating Systems Operating System Edition 1 Data Width 2 Microsoft Windows Server 2012 R2 Standard Datacenter2 Foundation 64-bit Microsoft Windows Server Standard2 Datacenter2 Foundation 64-bit Web 64-bit Microsoft Windows Web Server 2008 R2 3 Microsoft Windows Server 2008 R2 SP1 2 Standard Enterprise2 64-bit Microsoft Windows Server 2008 SP23 Web Standard Enterprise 64-bit4-9 -
10 Operating System Edition Data Width 1. Initial installation of EMSS on this family of operating systems when Core mode is enabled is not supported; a GUI is required. However, following installation, general operation of EMSS while Core mode is enabled is supported. For more information on enabling and disabling Core mode on Windows 2012 and 2012 R2 servers, see HEAT KnowledgeBase Article 1642 ( The Hyper-V edition of this operating system edition is supported, however, the Microsoft Hyper-V Server 2012 stand-alone edition is not. 3. The Datacenter and Core editions of this operating system family are not supported. 4. New installations of EMSS are only supported on the 64-bit version of this operating system. However, if upgrading 8.4 from a prior supported version of EMSS, the 32-bit version of this operating system is still supported. Supported Languages and Locales can only be installed on servers for certain languages and locales. Ensure the target server you are installing on uses one of the listed languages and locales. EMSS is installable on the following locales. The installer is available only in English. Table 3: Server Supported Locales Language Locale Identifier English: United States English: Australia English: Belize English: Canada English: India English: Ireland English: Jamaica English: New Zealand English: Philippines English: Singapore English: South Africa English: United Kingdom German: Germany Spanish: Spain (Modern Sort) en-us en-au en-bz en-ca en-in en-ie en-jm en-nz en-ph en-sg en-az en-gb de-de es-es
11 System Requirements After installing EMSS, you can use a translated UI by selecting one of the following languages in your Web browser. Table 4: Server Supported Languages Language Language Identifier English: United States French: France German: Germany Spanish: Spain (Modern Sort) en-us fr-fr de-de es-es Software Requirements Your server requires other software to operate. Review the listed software requirements to confirm your server has the required software. Before you begin installation of EMSS you must install the following software on your server or another supported location: Software Documentation Supported Web Browsers Web Browser Requirements on page 12 EMSS requires additional, supplemental software, but the EMSS will install it for you during installation: Software Documentation Microsoft SQL Server Microsoft.NET Framework Microsoft Windows Installer Microsoft Silverlight 5.0 Microsoft Visual C SP1 Redistributable Package (x86 and x64) Microsoft Visual C Update 4 Redistributable Package (x86 and x64) SQL Server Requirements on page 13.NET Framework Requirements on page 15 IIS Requirements on page 14.NET Framework Requirements on page 15 Note: Although EMSS installs an instance of SQL Server 2014, (x64), installing an instance yourself is best practice when supporting an enterprise environment
12 Web Browser Requirements You need one of several specific Web browsers to use the HEAT Endpoint Management and Security Suite Web console after installation. Table 5: Supported Web Browsers Supported Browser Supported Versions Microsoft Internet Explorer Mozilla Firefox 38 Extended Support Release 31 Extended Support Release Important: Microsoft Silverlight 5.0 is also required to use HEAT Installation Manager. Due to the accelerated release cycle of the Mozilla Firefox Rapid Release, support cannot be guaranteed
13 System Requirements SQL Server Requirements requires an instance of Microsoft SQL Server to store its data. Multiple version of SQL Server are supported. You can use an instance of any of the following versions. Table 6: Supported Database Servers Database Data Width Edition SQL Server 2014 SP1 x86/x64 Express Standard Enterprise Business Intelligence SQL Server 2014 x86/x64 Express Standard Enterprise Business Intelligence SQL Server 2012 and later x86/x64 Express Standard Enterprise SQL Server 2008 R2 SP1 and later x86/x64 Express Standard Enterprise SQL Server 2008 SP2 and later x86/x64 Express Standard Enterprise Note: HEAT recommends using the latest service pack available for your instance of SQL Server. If installing to a 64-bit server, HEAT recommends installing using a supported preexisting instance of SQL Server that supports 64-bit architecture. For evaluation installs, EMSS installs an instance of SQL Server 2014 Express SP1, which you can later upgrade to Standard or Enterprise before adding EMSS to a production environment. If you are evaluating EMSS, and you have no intent of using SQL Server 2014 Express SP1, your evaluation installation of EMSS should use your preferred version of SQL Server
14 You can install one of the supported database servers instances listed above in the following locations relative to the EMSS server. Table 7: Supported Database Instance Install Locations Location On the target EMSS server itself, as installed by the HEAT server installer, which installs an instance of SQL Server 2014 Express SP1 (x64). On the target HEAT server itself, using a preexisting instance of SQL Server. On a remote server that the HEAT server remotely connects to, using a preexisting instance of SQL Server. Important: When installing EMSS using an existing SQL Server instance, the instance collation must be set to one of the following values: SQL_Latin1_General_CP1_CI_AS Latin1_General_CI_AS IIS Requirements Before you can install EMSS, Microsoft Internet Information Services 7.0 or later must be installed. Table 8: Internet Information Services (IIS) Requirements Required IIS Operating System Family Version Microsoft Documentation Microsoft Internet Information Services 7.0+ Microsoft Windows Server 2012 R2 installing-iis-85-on-windows-server-2012-r2 Microsoft Windows Server Microsoft Windows Server 2008 R2 cc aspx Microsoft Windows Server cc771209(ws.10).aspx
15 System Requirements.NET Framework Requirements EMSS requires installation of.net Framework Microsoft Windows Server 2012 and 2012 R2 use.net 4.5, which comes installed by default. Table 9:.NET Framework Requirements Required.NET Framework Version Operating System Family Microsoft.NET Framework Microsoft.NET Framework with KB Note: EMSS provides the.net Framework installer during installation or upgrade (reboot required). Microsoft Windows Web Server 2008 R2 Microsoft Windows Server 2008 R2 SP1 Microsoft Windows Server 2008 SP2 Microsoft Windows Server 2012 Microsoft Windows Server 2012 R2 Hardware Requirements The server must meet or exceed the specified hardware requirements. Note: Installing the EMSS server on a dedicated server is recommended. The minimum hardware recommendation is designed for trial environments of 50 endpoints. For a EMSS configuration ideal for your environment, see Recommended Configurations on page GHz dual-core processor 4 GB RAM 50 GB or more hard drive space RAID 1 disk array 7200 RPM drive speed 1 Gbps Network Card
16 Network Requirements Your EMSS server needs access to specific websites and network services. Network Requirement Server Role: Your EMSS should not be a domain controller. Firewall Access URLs for replication and agent communication: (For Microsoft content) (For Microsoft content) (For Adobe content) (For Adobe content) (For Adobe content) (For Adobe content) Important: Network Discovery Windows Services: Refer to HEAT KnowledgeBase Article 539 ( and HEAT KnowledgeBase Article 334 ( for additional URLs and IP Addresses which may be required depending upon your configuration and content subscriptions. The firewalls on your server may require modification to access these URLs. If your corporate policies do not allow you to make the necessary firewall modifications, please contact HEAT Support ([email protected]) for a recommended configuration. EMSS uses the server Network Discovery Windows Services to discover other computers and devices on your network and installation. At time of install, the EMSS installer prompts you to enable these services: DNS Client Function Discovery Resource Publication SSDP Discovery UPnP Device Host
17 System Requirements Network Requirement Encryption Protocols: EMSS uses Transport Layer Security for communication between the HEAT EMSS Server and the HEAT EMSS Agent: TLS 1.0, 1.1, and 1.2. EMSS prompts you to enable these protocols during installation. Note: If you do not plan on supporting Windows XP, Vista, Server 2003, or Server 2008 endpoints, you can disable TLS 1.0 and 1.1 to improve security. See for more information. Recommended Configurations HEAT recommends different hardware and software requirements customized for your HEAT Endpoint Management and Security Suite network setup. Server Configuration Considerations EMSS requires two main components to function: EMSS Application Server: This server is responsible for Web site, replication services, and endpoint distribution services. EMSS Database Server: This server is responsible for SQL database and stored procedures. These servers can be installed on a single server, or on two, separate servers. Combined Application and Database Server: In configurations where the EMSS application and database are installed on the same server, the server requires both high processing power and disk speed, as it is performs both application and database functions. Combined EMSS Application and Database Server on page 18 Separate Application and Database Servers: In configurations where the EMSS application and database are installed on separate servers, the server requirements are different. Although processing and software requirements on both servers remain the same, the database requires increased HDD specifications, as it executes disk-intensive functions. Separated EMSS Application and Database Servers on page 19 Endpoint Scaling Considerations Regardless of your EMSS application and database configuration, your server (or servers) require increasingly high-end hardware and software to offset increased load from endpoints. Use better hardware in environments with a high endpoint count
18 Additional Considerations For additional information about the physical memory limits for Windows releases, refer to Memory Limits for Windows Releases ( aa366778(v=vs.85).aspx). For additional information about moving SQL Server databases, refer to Move System Databases ( For additional information about Microsoft's top ten best practices for storage, refer to Storage Top Ten Best Practices ( Combined EMSS Application and Database Server For optimal performance, the hardware and software supporting HEAT Endpoint Management and Security Suite should be scaled to your endpoint count. The following table lists the recommended hardware and software for you EMSS network. Note: Installation on a physical server is assumed. If installing to virtual environment, refer to HEAT KnowledgeBase Article 258 ( Combined Server Recommended Configuration < 50 < 500 < 1,000 < 5,000 < 10,0001 Operating System Windows 2012 R2 Windows 2012 R2 Windows 2012 R2 Windows 2012 R2 Windows 2012 R2 Operating System Edition Standard Standard Standard Standard Standard x64 x64 x64 x64 x64 Database Server SQL 2014 SQL 2014 SQL 2014 SQL 2014 SQL 2014 Database Server Edition Standard2 Standard Standard Standard Enterprise x64 x64 x64 x64 x64 Core Architecture Core Speed (GHz) Gb/s 1 Gb/s 1 Gb/s 1 Gb/s 1 Gb/s RAID 1 RAID 1 Multiple RAID Multiple RAID Multiple RAID k/SSD 10k/SSD 15k/SSD Endpoint Count Software Operating System Architecture Database Server Architecture Hardware RAM (GB)4 Network (LAN) Disk Array 5 # Hard Drives Drive Speed (RPM)
19 System Requirements Endpoint Count < 50 < 500 < 1,000 < 5,000 < 10,0001 Hard Drive Volume Breakdown OS/Data 250GB 500GB N/A N/A N/A OS N/A N/A RAID 1-250GB RAID 1-250GB RAID 1-250GB Data N/A N/A RAID 1-500GB RAID 1/ SSD - 1TB RAID 10/ SSD - 1TB Temp DB N/A N/A N/A RAID 0-250GB SSD 240GB 1. If you are managing endpoints, contact HEAT Support ( for a recommended configuration. 2. Evaluation customers should use Express edition with Advanced Services. 3. A Sandy Bridge Xeon+ or AMD equivalent is recommended. On virtualized servers, 2x the assigned cores is recommended. 4. On virtualized servers, 2x RAM is recommended for networks supporting endpoints. 5. Due to performance issues, do not use RAID 5 configurations. Replace the disk array with a shared SAN, an enterprise-class SSD, or another enterprise storage solution IOPS minimum sustained performance is recommended. A dedicated array or LUN is recommended. Separated EMSS Application and Database Servers When the Application Server and Database Server are installed on two physical servers, then each servers recommended hardware requirements will increase according to the number of managed endpoints in your network. Review the following information when the components are installed on separate servers. Note: Installation on a physical server is assumed. If installing to virtual environment, refer to HEAT KnowledgeBase Article 258 ( Recommended Application Server Configuration The following table lists the recommended configuration for the Application Server. < 50 < 500 < 1,000 < 5,000 < 10,0001 Operating System Windows 2012 R2 Windows 2012 R2 Windows 2012 R2 Windows 2012 R2 Windows 2012 R2 Operating System Edition Standard Standard Standard Standard Standard Endpoint Count Software
20 < 50 < 500 < 1,000 < 5,000 < 10,0001 Operating System Architecture x64 x64 x64 x64 x64 Core Architecture Core Speed (GHz) Gb/s 1 Gb/s 1 Gb/s 1 Gb/s 1 Gb/s RAID 1 RAID 1 RAID 1/SSD RAID 1/SSD RAID 1/SSD k/SSD 10k/SSD 10k/SSD Endpoint Count Application Server Hardware RAM (GB)3 Network (LAN) 4 Disk Array # Hard Drives Drive Speed (RPM) Hard Drive Volume Breakdown OS/Data (GB) If you are managing endpoints, contact HEAT Support ( for a recommended configuration. 2. A Sandy Bridge Xeon+ or AMD equivalent is recommended. On virtualized servers, 2x the assigned cores is recommended. 3. On virtualized servers, 2x RAM is recommended for networks supporting endpoints. 4. Due to performance issues, do not use RAID 5 configurations. Replace the disk array with a shared SAN, an enterprise-class SSD, or another enterprise storage solution IOPS minimum sustained performance is recommended. A dedicated array or LUN is recommended. Recommended SQL Server Configuration The following table lists the recommended configuration for the Database Server. < 50 < 500 < 1,000 < 5,000 < 10,0001 Operating System Windows 2012 R2 Windows 2012 R2 Windows 2012 R2 Windows 2012 R2 Windows 2012 R2 Operating System Edition Standard Standard Standard Standard Standard x64 x64 x64 x64 x64 SQL 2014 SQL 2014 SQL 2014 SQL 2014 SQL 2014 Endpoint Count Software Operating System Architecture Database Server
21 System Requirements < 50 < 500 < 1,000 < 5,000 < 10,0001 x64 x64 x64 x64 x64 Standard2 Standard Standard Standard Enterprise Core Architecture Core Speed (GHz) Gb/s 1 Gb/s 1 Gb/s 1 Gb/s 1 Gb/s RAID 1 RAID 1 Multiple RAID Multiple RAID Multiple RAID k/SSD 10k/SSD 15k/SSD Endpoint Count Database Server Architecture Database Server Edition SQL Server Hardware 3 RAM (GB)4 Network (LAN) Disk Array 5 # Hard Drives Drive Speed (RPM) Hard Drive Volume Breakdown OS/Data (GB) N/A N/A N/A OS (GB) N/A N/A RAID RAID RAID Data N/A N/A RAID 1-500GB RAID 1/ SSD - 1TB RAID 10/ SSD - 1TB Temp DB (GB) N/A N/A N/A RAID SSD If you are managing endpoints, contact HEAT Support ( for a recommended configuration. 2. Evaluation customers should use Express edition with Advanced Services. 3. A Sandy Bridge Xeon+ or AMD equivalent is recommended. On virtualized servers, 2x the assigned cores is recommended. 4. On virtualized servers, 2x RAM is recommended for networks supporting endpoints. 5. Due to performance issues, do not use RAID 5 configurations. Replace the disk array with a shared SAN, an enterprise-class SSD, or another enterprise storage solution IOPS minimum sustained performance is recommended. A dedicated array or LUN is recommended
22 - 22 -
23 Chapter 2 Installing HEAT Endpoint Management and Security Suite In this chapter: Downloading EMSS About SQL Server Instance Location Defining the Web Client Account and Service Account Selecting an Installation Method Installing Using a New SQL Server Instance Complete the installation method that is best for your network environment. Before installation, download the latest HEAT Endpoint Management and Security Suite (EMSS) installer. There is an installation procedure for all EMSS installation scenarios. After installation, complete any additional procedures associated with the installation method. Installing Using an Existing SQL Server Instance (Either Locally or Remotely) Installing Using a Remote SQL Server Instance (with no Local Instance) Installing HEAT Endpoint Management and Security Suite (Separate EMSS and SQL Server Admins) Logging In to HEAT Endpoint Management and Security Suite Setting Up HEAT Endpoint Management and Security Suite Downloading EMSS When you purchase, you receive no physical media. Rather, you download it from the company Web site. Download EMSS from the HEAT Customer Portal (
24 1. Open your Web browser. 2. Browse to the HEAT Customer Portal ( 3. Browse to and download the most recent version of the EMSS installer to your desired location. After Completing This Task: Complete the installation procedure applicable to your network environment. For additional information, refer to Selecting an Installation Method on page 25. About SQL Server Instance Location requires an instance of Microsoft SQL Server to store system data values. You can install this SQL Server instance on your target EMSS server or a remote server. Local SQL Server Instance A SQL Server instance can be installed on the same server as HEAT Endpoint Management and Security Suite. When using a local SQL Server instance, you can use either a named or default instance of SQL Server that is preexisting, or you can use a new instance of SQL Server (which is set up by the Log Collector installer). Remote SQL Server Instance A SQL Server instance can be installed on a different server than EMSS, and EMSS can then access that remote instance. If you elect to use a remote SQL Server instance, you must direct EMSS toward the remote instance during EMSS installation. However, before directing EMSS to the remote instance, you must configure that instance to accept remote connections. For additional information, refer to Configuring SQL Server to Accept Remote Connections on page 86. Tip: Install EMSS using a remote SQL Server instance to increase performance. Defining the Web Client Account and Service Account requires two user accounts to operate critical components: a Web client account and a service account. HEAT recommends creating new local user accounts to use as Web client and service accounts (as defined in the installation procedures). However, you can also use preexisting local or domain accounts. When using preexisting local or domain accounts, certain requirements must be fulfilled. Remember
25 Installing the following rules if you use preexisting user accounts when installing EMSS using a remote instance of SQL Server: In cross-domain network configurations, accounts from either domain may be used as the Web client and service accounts, but the domains must have a trust relationship. Any install in which either the EMSS server or the SQL server is in a workgroup must use local accounts as the Web client and service accounts. When using local accounts as the Web client and service accounts, there must be a duplicate of each account on each server. For example, if the EMSS server hosts an account named serviceadmin with a password of Password.0, then the SQL server must host an account called serviceadmin with a password of Password.0. When using a domain account for the service accounts it must also belong to the local Administrator group in order to run critical services including Internet Information Services (IIS). Note: You can use existing user accounts as the Web client account and service account. However, HEAT recommends creating new accounts specifically for EMSS using the installer (if using a remote SQL Server instance, manual creation of identical accounts is required). Creating accounts specifically for the product increases security and automates creation of trust relationships. Selecting an Installation Method There are multiple methods of installing the product. When installing, identify the scenario that best suits your network environment, and complete the scenario according to the provided procedures. For small network environments that do not require complex instances of SQL Server, complete the basic (EMSS) installation. This installation includes an installation of Microsoft SQL Server 2014, Express Edition (x64). This installation method is the simplest EMSS method. Installing Using a New SQL Server Instance on page 26 For larger network environments, the EMSS installation requires a more sophisticated SQL Server instance that must be installed independently from EMSS. This instance of SQL Server, which must be installed before EMSS, can be installed on either the target EMSS server or a remote server. Installing Using an Existing SQL Server Instance (Either Locally or Remotely) on page 36 Installing Using a Remote SQL Server Instance (with no Local Instance) on page 50 In especially large environments, the SQL Server administrator and the EMSS administrator may be separate individuals. In this scenario, a special installation procedure is required due to administrator access right limitations. Installing (Separate EMSS and SQL Server Admins) on page 63 Attention: Complete Downloading EMSS on page 23 before beginning an installation procedure
26 Installing Using a New SQL Server Instance If SQL Server is not installed on your target server, or if you want to use a new instance instead of an existing one, you can create a new SQL Server 2014, Express Edition (x64) instance during the HEAT Endpoint Management and Security Suite installation. Prerequisites: You have completed Downloading EMSS on page 23. As applicable to your network environment, you have gathered the information and completed the tasks itemized in the Server Installation Checklist on page 97. Note: For additional information about using preexisting user accounts to operate critical EMSS components, refer to Defining the Web Client Account and Service Account on page 24. If you are installing using a Secure Sockets Layer (SSL), complete the first portion of Configuring SSL on page Log on to the server on which you want to install EMSS using either a local or domain user account with system administrator privileges. 2. Stop or disable any AntiVirus products (such as McAfee, Trend-micro, Symantec, and so on) running on your server. Note: An AntiVirus product can prevent processes from running correctly during the installation. Therefore, to ensure a successful installation, all AntiVirus services must be stopped or disabled prior to running the EMSS installer. 3. Double-click the EMSS installer at the location defined during the download. Step Result: The EMSS InstallShield Wizard opens and begins extracting files. This process may take several minutes. 4. If prompted, install prerequisites and reboot your server. The installer reopens by itself after the reboot. 5. Click Next. Step Result: The License Agreement page opens. Tip: Click Print for a hard copy of the license agreement. 6. Review the License Agreement and select the I accept the terms of the license agreement option
27 Installing 7. Click Next. Step Result: The Customer Information page opens. Figure 1: Customer Information Page 8. Type the applicable information in the following fields: Field Description Company Name Your company name. Serial Number Your EMSS serial number. Note: Your serial number is two groups of eight alphanumeric characters. Letters are not case sensitive. If you cannot locate your serial number, obtain it by contacting the HEAT Sales Support Tip: Retain your serial number following installation, as it is necessary if a reinstall of the EMSS server is needed
28 9. Click Next. A new page or dialog opens. Page/Dialog Step If the Question dialog opens: Click Yes to start network discovery services. The following services are necessary to use discovery features within EMSS: If the Required IIS Features page opens: DNS Client Function Discovery Resource Location SSDP Discover UPnP Device Host Your server does not have the required IIS features installed. Click Install Features to install the features and proceed. Note: On Windows Server 2008, the default installation of IIS lacks components necessary for EMSS. The EMSS installer installs the following IIS components if not present: Static Content Default Document HTTP Errors ASP.NET.NET Extensibility ASP ISAPI Extensions ISAPI Filters Basic Authentication Windows Authentication Static Content Compression Dynamic Content Compression
29 Installing Page/Dialog Step If the System Requirements page opens: Your server does not meet the minimum installation requirements. If you receive only system requirement warnings, you may proceed with installation by clicking Next. HEAT recommends resolving warnings before proceeding with installation. Note: When installing on a virtual platform you will likely receive a warning about the CPU requirements since the installer is unable to identify the processor in a virtual environment. If you receive any system requirement failures, you must cancel the installation, resolve these failures, and then restart installation. Tip: Click View all Failures/Warnings for detailed information about prerequisite status deficiencies. If the Service Accounts page opens: Proceed to the next step. 10.Create or define the Web client account and service account that EMSS will use. These accounts are used to operate components critical to EMSS. Select from the following options. Option To create new accounts: Steps 1. Edit the Web Client Account Username field. 2. In the Web Client Account Password field, type the desired password. 3. In the Web Client Account Confirm password field, retype the password. 4. Edit the Service Account Username field. 5. In the Service Account Password field, type the desired password. 6. In the Service Account Confirm password field, retype the password. Note: If you create new Web client account and service account, HEAT recommends using the default account user names the installation creates; clientadmin for the Web client account, and serviceadmin for the service account
30 Option To use preexisting accounts: Steps 1. Type the user name associated with the desired account in the Web Client Account Username field. 2. Type the password associated with the user name in the Web Client Account Password field. 3. Retype the password in the Web Client Account Confirm password field. 4. Type the user name associated with the desired account in the Service Account Username field. 5. Type the password associated with the service account user name in the Service Account Password field. 6. Retype the password in the Service Account Confirm password field Note: HEAT recommends creating new accounts. If using domain accounts, include the domain name as part of the user name (DOMAIN\Username). You may only use preexisting accounts if they meet the requirements defined in Defining the Web Client Account and Service Account on page
31 Installing 11.Click Next. If required, acknowledge the creation of new accounts by clicking OK. Step Result: The SQL Server Instance page opens. Figure 2: SQL Server Instance Page 12.Select the Install a new SQL Server instance option. 13.[Optional] Type a new instance name in the Instance Name field
32 14.Click Next. Step Result: The Destination Location page opens. Figure 3: Destination Location Page 15.[Optional] Change the EMSS installation location. a) Click Browse. b) Define the desired file path using either the Look in lists or the Folder name field. c) Click OK. Step Result: The Installation Folder field reflects your changes. 16.[Optional] Change the EMSS content storage location. The content storage location is the location where patches and other content items are downloaded. HEAT recommends allocating at least 32 GB of storage space to content (plus an additional 10 GB if managing non-windows endpoints). a) Click Browse. b) Define the desired file path using either the Look in lists or the Folder name field. c) Click OK. Step Result: The Content Storage Location field reflects your changes
33 Installing 17.Click Next. Step Result: The Proxy Settings page opens. Note: Refer to the : Requirements Guide ( for a complete list of proxy types that EMSS supports. Figure 4: Proxy Settings Page Note: If one or both of the storage directories defined on the Destination Location page does not contain the recommended available disk space, the Proxy Settings page does not immediately open. Rather, a dialog that lets you redefine the storage directories will open. Then after redefining the storage directories, the Proxy Settings page will open. 18.If your network uses a proxy server to access the Internet, select the A proxy server is required check box and type the applicable information in the following fields. Field Type Server Address The IP address of the applicable proxy server
34 Field Type Port The port number used for communication. Note: You can also configure EMSS to use a proxy following installation. Refer to The Service Tab in the User Guide ( for additional information on proxy communication. 19.If your network uses a proxy server to access the Internet, and that proxy requires authentication, select the Authentication required check box and type the applicable information in the following fields. Field Type Username A user name that authenticates with the proxy. Password The password associated with the user name. Confirm Password The password retyped. 20.Click Next. Step Result: The Agent to Server Communication page opens. Figure 5: Agent to Server Communication Page
35 Installing 21.If you are using SSL for server and agent communication, select the Use SSL security for Patch agent communication with the server check box. Note: You must possess an SSL certificate to implement SSL communication. Implementation of SSL communication during installation is optional. This feature can be implemented following installation. 22.In the Default server identity field, type the name of your server in one of the following formats: DNS name (computername.domainname.com) Computer name (computername) IP address ( ) During agent registration, the EMSS agents use this name to identify the server. Note: If you are using SSL, the server name that you type in the field must match the server named on your certificate. 23.Click Next. Step Result: The Installation Ready page opens. Figure 6: Installation Ready Page
36 24.[Optional] If you only want to install core components, clear the Automatically include all licensed modules and updates during installation check box. Note: You may use the HEAT Installation Manager after the initial installation of EMSS to install additional components. For additional information, refer to Using HEAT Installation Manager in the User Guide ( 25.Review the installation information and click Install to begin the installation of EMSS. This process may take several minutes. Important: During installation, do not attempt to access the EMSS Web site. Accessing the Web site during installation can cause installation errors. 26.After installation completes, click Finish. 27.Acknowledge the notification that appears by clicking OK. The credentials you use to log in to the EMSS Web site for the first time are the credentials that you used when you logged into the server initially. Result: EMSS is installed and can now be accessed. After Completing This Task: Proceed to one of the following procedures based on selections made during installation. If your server will use SSL, finish Configuring SSL on page 89. If your server will not use SSL, proceed to Logging In to HEAT Endpoint Management and Security Suite on page 78. Installing Using an Existing SQL Server Instance (Either Locally or Remotely) You can configure your installation to use a SQL Server instance that exists either locally or remotely. Prerequisites: Complete Downloading EMSS on page 23. As applicable to your network environment, you have gathered the information and completed the tasks itemized in the Server Installation Checklist on page 97. If you are installing using SSL, complete the first portion of Configuring SSL on page 89 If you are installing using a remote instance of SQL Server, complete Configuring SQL Server to Accept Remote Connections on page 86 Additionally, if you are installing using a remote instance of SQL Server, and no instances of SQL Server exist locally, complete Installing Using a Remote SQL Server Instance (with no Local Instance) on page 50 rather than this procedure
37 Installing 1. If installing using a remote instance of SQL Server, complete Creating Remote Accounts on page 83. Note: If using preexisting accounts, you may skip completion of this step. 2. Using either a local or domain account with system administrator privileges, log in to the server on which you will install EMSS. 3. Stop or disable any AntiVirus products (such as McAfee, Trend-micro, Symantec, and so on) running on your server. Note: An AntiVirus product can prevent processes from running correctly during the installation. Therefore, to ensure a successful installation, all AntiVirus services must be stopped or disabled prior to running the EMSS installer. 4. Double-click the EMSS installer at the location defined during the download. Step Result: The EMSS InstallShield Wizard opens and begins extracting files. This process may take several minutes. 5. If prompted, install prerequisites and reboot your server. The installer reopens by itself after the reboot. 6. Click Next. Step Result: The License Agreement page opens. Tip: Click Print for a hard copy of the license agreement. 7. Review the License Agreement and select the I accept the terms of the license agreement option
38 8. Click Next. Step Result: The Customer Information page opens. Figure 7: Customer Information Page 9. Type the applicable information in the following fields: Field Description Company Name Your company name. Serial Number Your EMSS serial number. Note: Your serial number is two groups of eight alphanumeric characters. Letters are not case sensitive. If you cannot locate your serial number, obtain it by contacting the HEAT Sales Support Tip: Retain your serial number following installation, as it is necessary if a reinstall of the EMSS server is needed
39 Installing 10.Click Next. A new page or dialog opens. Page/Dialog Step If the Question dialog opens: Click Yes to start network discovery services. The following services are necessary to use discovery features within EMSS: If the Required IIS Features page opens: DNS Client Function Discovery Resource Location SSDP Discover UPnP Device Host Your server does not have the required IIS features installed. Click Install Features to install the features and proceed. Note: On Windows Server 2008, the default installation of IIS lacks components necessary for EMSS. The EMSS installer installs the following IIS components if not present: Static Content Default Document HTTP Errors ASP.NET.NET Extensibility ASP ISAPI Extensions ISAPI Filters Basic Authentication Windows Authentication Static Content Compression Dynamic Content Compression
40 Page/Dialog Step If the System Requirements page opens: Your server does not meet the minimum installation requirements. If you receive only system requirement warnings, you may proceed with installation by clicking Next. HEAT recommends resolving warnings before proceeding with installation. Note: When installing on a virtual platform you will likely receive a warning about the CPU requirements since the installer is unable to identify the processor in a virtual environment. If you receive any system requirement failures, you must cancel the installation, resolve these failures, and then restart installation. Tip: Click View all Failures/Warnings for detailed information about prerequisite status deficiencies. If the Service Accounts page opens: Proceed to the next step. 11.Define the Web client account and service account that EMSS will use. Define these accounts based on how you are configuring your EMSS server. Option Steps If your install will use a local SQL Server instance: Define the credentials for two new user accounts (which are created by the installer). 1. In the Web Client Account Username field, edit the user name. 2. In the Web Client Account Password field, type a password. 3. In the Web Client Account Confirm password field, retype the password. 4. In the Service Account Username field, edit the user name. 5. In the Service Account Password field, type a password. 6. In the Service Account Confirm password field, retype the password
41 Installing Option Steps If your install will use a remote SQL Server instance: Define the credentials for the two user accounts created while completing Creating Remote Accounts on page In the Web Client Account Username field, type the user name of the Web client account on your SQL Server. 2. In the Web Client Account Password field, type the password of the Web client account on your SQL Server. 3. In the Web Client Confirm password field, retype the password. 4. In the Service Account Username field, type the user name of the service account on your SQL Server. 5. In the Service Account Password field, type the password of the service account on your SQL Server. 6. In the Service Account Confirm password field, retype the password. Important: The Web client account and the service account credentials must be identical on both the SQL Server and the EMSS server. If they are not, you cannot access the EMSS Web site. If your install will use a local or remote SQL Server instance that uses preexisting accounts as the Web Client and Service Accounts: Define the credentials for the preexisting accounts. 1. Type the user name associated with the desired account in the Web Client Account Username field. 2. Type the password associated with the user name in the Web Client Account Password field. 3. Retype the password in the Web Client Account Confirm password field. 4. Type the user name associated with the desired account in the Service Account Username field. 5. Type the password associated with the service account user name in the Service Account Password field. 6. Retype the password in the Service Account Confirm password field. Important: You can use either local or domain accounts. If using domain accounts, include the domain name as part of the user name (DOMAIN\username). Additionally, preexisting accounts may only be used if they meet the requirements listed in Defining the Web Client Account and Service Account on page
42 12.Click Next. If required, acknowledge the creation of new accounts by clicking OK. Step Result: The SQL Server Instance page opens. Figure 8: SQL Server Instance Page 13.Ensure the Connect to an existing SQL Server instance option is selected
43 Installing 14.Click Next. Step Result: The SQL Server and Instance page opens. Use this page to define the SQL Server instance you will use with EMSS. Figure 9: SQL Server and Instance Page 15.Select a Server Location. Select one of the following options. Option Steps To use a locally installed existing SQL Server instance: Select the On this machine (local) option. To use a remotely installed existing SQL Server instance: 1. Select the On another machine (remote) option. 2. Type the server name (not the IP address) in the Server name field. Note: If you must define an IP address, either map the IP address to the server name in the hosts file or create an alias using SQL Server Configuration Manager
44 16.Select a SQL Server Instance. Select one of the following options: Option Steps To use a default instance of SQL Server: Select the Default instance option. To use a named instance of SQL Server: 1. Select the Named instance option. 2. If the SQL Server instance is local, select it from the list. If the SQL Server instance is remote, type its name in the field. 17.Click Next. Step Result: The SQL Server Authentication page opens. Figure 10: SQL Server Authentication Page 18.Define the credentials that will be used to access the SQL Server instance (based upon its authentication mode). Select from the following options: Option Steps To use Windows authentication: Select the Windows Authentication option
45 Installing Option To use SQL Server authentication: Steps 1. Select the SQL Server Authentication option. 2. Type a user name that will validate with the SQL Server instance in the Login field. 3. Type the password associated with the user in the Password field. Note: The credentials used to access the SQL Server instance must be assigned the sysadmin system role within Microsoft SQL Server Management Studio. If the user account defined is not assigned this role, the The credentials provided do not have sufficient privileges to continue dialog opens after clicking Next. You need to define a user account and assigned the sysadmin system role before you can continue. If you cannot be assigned this role due to network security policies and procedures that split administrative duties between a EMSS administrator and a SQL Server administrator, refer to Installing (Separate EMSS and SQL Server Admins) on page Click Next. A new page opens. Page Steps If the Destination Location page opens: Click Next and proceed to the next step. If the SQL Server Configuration Requirements page opens: The pre-installed instance of SQL Server is not configured to work with EMSS. If you only receive SQL Server configuration requirement informationals or warnings, click Next to continue (the EMSS installation will automatically reconfigure SQL Server). Proceed to the next step. If you receive any SQL Server configuration requirement failures, you must cancel the installation, resolve the failures, and then proceed with the installation. Tip: Click View Configuration Detail for detailed information about SQL Server configuration status requirements. 20.[Optional] Change the EMSS installation location. a) Click Browse. b) Define the desired file path using either the Look in lists or the Folder name field
46 c) Click OK. Step Result: The Installation Folder field reflects your changes. 21.[Optional] Change the EMSS content storage location. The content storage location is the location where patches and other content items are downloaded. HEAT recommends allocating at least 32 GB of storage space to content (plus an additional 10 GB if managing non-windows endpoints). a) Click Browse. b) Define the desired file path using either the Look in lists or the Folder name field. c) Click OK. Step Result: The Content Storage Location field reflects your changes
47 Installing 22.Click Next. Step Result: The Proxy Settings page opens. Note: Refer to the : Requirements Guide ( for a complete list of proxy types that EMSS supports. Figure 11: Proxy Settings Page Note: If one or both of the storage directories defined on the Destination Location page does not contain the recommended available disk space, the Proxy Settings page does not immediately open. Rather, a dialog that lets you redefine the storage directories will open. Then after redefining the storage directories, the Proxy Settings page will open. 23.If your network uses a proxy server to access the Internet, select the A proxy server is required check box and type the applicable information in the following fields. Field Type Server Address The IP address of the applicable proxy server
48 Field Type Port The port number used for communication. Note: You can also configure EMSS to use a proxy following installation. Refer to The Service Tab in the User Guide ( for additional information on proxy communication. 24.If your network uses a proxy server to access the Internet, and that proxy requires authentication, select the Authentication required check box and type the applicable information in the following fields. Field Type Username A user name that authenticates with the proxy. Password The password associated with the user name. Confirm Password The password retyped. 25.Click Next. Step Result: The Agent to Server Communication page opens. Figure 12: Agent to Server Communication Page
49 Installing 26.If you are using SSL for server and agent communication, select the Use SSL security for Patch agent communication with the server check box. Note: You must possess an SSL certificate to implement SSL communication. Implementation of SSL communication during installation is optional. This feature can be implemented following installation. 27.In the Default server identity field, type the name of your server in one of the following formats: DNS name (computername.domainname.com) Computer name (computername) IP address ( ) During agent registration, the EMSS agents use this name to identify the server. Note: If you are using SSL, the server name that you type in the field must match the server named on your certificate. 28.Click Next. Step Result: The Installation Ready page opens. Figure 13: Installation Ready Page
50 29.[Optional] If you only want to install core components, clear the Automatically include all licensed modules and updates during installation check box. Note: You may use the HEAT Installation Manager after the initial installation of EMSS to install additional components. For additional information, refer to Using HEAT Installation Manager in the User Guide ( 30.Review the installation information and click Install to begin the installation of EMSS. This process may take several minutes. Important: During installation, do not attempt to access the EMSS Web site. Accessing the Web site during installation can cause installation errors. 31.After installation completes, click Finish. 32.Acknowledge the notification that appears by clicking OK. The credentials you use to log in to the EMSS Web site for the first time are the credentials that you used when you logged into the server initially. Result: EMSS is installed and can now be accessed. After Completing This Task: Proceed to one of the following procedures based on selections made during installation. If your server will use SSL, finish Configuring SSL on page 89. If your server will not use SSL, proceed to Logging In to HEAT Endpoint Management and Security Suite on page 78. Installing Using a Remote SQL Server Instance (with no Local Instance) Installing using an existing remote SQL Server instance differs slightly when no SQL Server instance exists locally. Prerequisites: Complete Downloading EMSS on page 23. As applicable to your network environment, you have gathered the information and completed the tasks itemized in the Server Installation Checklist on page 97. Complete Configuring SQL Server to Accept Remote Connections on page 86 If installing using SSL, complete the first portion of Configuring SSL on page Complete Creating Remote Accounts on page 83. Note: If using preexisting accounts, you may skip completion of this procedure. 2. Using either a local or domain account with system administrator privileges, log in to the server on which you will install EMSS
51 Installing 3. Stop or disable any AntiVirus products (such as McAfee, Trend-micro, Symantec, and so on) running on your server. Note: An AntiVirus product can prevent processes from running correctly during the installation. Therefore, to ensure a successful installation, all AntiVirus services must be stopped or disabled prior to running the EMSS installer. 4. Double-click the EMSS installer at the location defined during the download. Step Result: The EMSS InstallShield Wizard opens and begins extracting files. This process may take several minutes. 5. If prompted, install prerequisites and reboot your server. The installer reopens by itself after the reboot. 6. Click Next. Step Result: The License Agreement page opens. Tip: Click Print for a hard copy of the license agreement. 7. Review the License Agreement and select the I accept the terms of the license agreement option. 8. Click Next. Step Result: The Customer Information page opens. Figure 14: Customer Information Page
52 9. Type the applicable information in the following fields: Field Description Company Name Your company name. Serial Number Your EMSS serial number. Note: Your serial number is two groups of eight alphanumeric characters. Letters are not case sensitive. If you cannot locate your serial number, obtain it by contacting the HEAT Sales Support Tip: Retain your serial number following installation, as it is necessary if a reinstall of the EMSS server is needed. 10.Click Next. A new page or dialog opens. Page/Dialog Step If the Question dialog opens: Click Yes to start network discovery services. The following services are necessary to use discovery features within EMSS: DNS Client Function Discovery Resource Location SSDP Discover UPnP Device Host
53 Installing Page/Dialog Step If the Required IIS Features page opens: Your server does not have the required IIS features installed. Click Install Features to install the features and proceed. Note: On Windows Server 2008, the default installation of IIS lacks components necessary for EMSS. The EMSS installer installs the following IIS components if not present: If the System Requirements page opens: Static Content Default Document HTTP Errors ASP.NET.NET Extensibility ASP ISAPI Extensions ISAPI Filters Basic Authentication Windows Authentication Static Content Compression Dynamic Content Compression Your server does not meet the minimum installation requirements. If you receive only system requirement warnings, you may proceed with installation by clicking Next. HEAT recommends resolving warnings before proceeding with installation. Note: When installing on a virtual platform you will likely receive a warning about the CPU requirements since the installer is unable to identify the processor in a virtual environment. If you receive any system requirement failures, you must cancel the installation, resolve these failures, and then restart installation. Tip: Click View all Failures/Warnings for detailed information about prerequisite status deficiencies. If the Service Accounts page opens: Proceed to the next step
54 11.Define the Web client account and service account that your EMSS server will use. Select from the following options. Option Steps To duplicate the accounts on 1. In the Web Client Account Username field, type the user your SQL Server: name of the Web client account on your SQL Server. 2. In the Web Client Account Password field, type the password of the Web client account on your SQL Server. 3. In the Web Client Account Confirm password field, retype the password. 4. In the Service Account Username field, type the user name of the service account on your SQL Server. 5. In the Service Account Password field, type the password of the service account on your SQL Server. 6. In the Service Account Confirm password field, retype the password. Important: The Web client account and the server account credentials must be identical on both the SQL Server and the EMSS server. If they are not, you cannot access the EMSS Web site. To use preexisting accounts: 1. Type the user name associated with the desired account in the Web Client Account Username field. 2. Type the password associated with the user name in the Web Client Account Password field. 3. Retype the password in the Web Client Account Confirm password field. 4. Type the user name associated with the desired account in the Service Account Username field. 5. Type the password associated with the service account user name in the Service Account Password field. 6. Retype the password in the Service Account Confirm password field. Important: You can use either local or domain accounts. If using domain accounts, include the domain name as part of the user name (DOMAIN\username). Additionally, preexisting accounts may only be used if they meet the requirements listed in Defining the Web Client Account and Service Account on page
55 Installing 12.Click Next. If required, acknowledge the creation of new accounts by clicking OK. Step Result: The SQL Server Instance Page opens. Figure 15: SQL Server Instance Page 13.Ensure the Connect to an existing SQL Server instance option is selected
56 14.Click Next. Step Result: The SQL Server and Instance page opens. Figure 16: SQL Server and Instance Page (No Local Options) Important: If Server Location options are available from this page, you are performing the wrong procedure. Instead, perform Installing Using an Existing SQL Server Instance (Either Locally or Remotely) on page Type the name (not the IP address) of the server hosting the remote SQL Server instance in the Server name field. 16.Based on the SQL Server instance you are using, select a SQL Server Instance option. Select one of the following options. Option Steps To use a default SQL Server instance: Select the Default instance option. To use a named SQL Server instance: 1. Select the Named instance option. 2. Type the instance name in the Named instance field
57 Installing 17.Click Next. Step Result: The SQL Server Authentication page opens. Figure 17: SQL Server Authentication Page 18.Define the credentials that will be used to access the SQL Server instance (based upon its authentication mode). Select from the following options: Option Steps To use Windows authentication: Select the Windows Authentication option
58 Option To use SQL Server authentication: Steps 1. Select the SQL Server Authentication option. 2. Type a user name that will validate with the SQL Server instance in the Login field. 3. Type the password associated with the user in the Password field. Note: The credentials used to access the SQL Server instance must be assigned the sysadmin system role within Microsoft SQL Server Management Studio. If the user account defined is not assigned this role, the The credentials provided do not have sufficient privileges to continue dialog opens after clicking Next. You need to define a user account and assigned the sysadmin system role before you can continue. If you cannot be assigned this role due to network security policies and procedures that split administrative duties between a EMSS administrator and a SQL Server administrator, refer to Installing (Separate EMSS and SQL Server Admins) on page Click Next. A new page opens. Page Steps If the Destination Location page opens: Click Next and proceed to the next step. If the SQL Server Configuration Requirements page opens: The pre-installed instance of SQL Server is not configured to work with EMSS. If you only receive SQL Server configuration requirement informationals or warnings, click Next to continue (the EMSS installation will automatically reconfigure SQL Server). Proceed to the next step. If you receive any SQL Server configuration requirement failures, you must cancel the installation, resolve the failures, and then proceed with the installation. Tip: Click View Configuration Detail for detailed information about SQL Server configuration status requirements
59 Installing 20.[Optional] Change the EMSS content storage location. The content storage location is the location where patches and other content items are downloaded. HEAT recommends allocating at least 32 GB of storage space to content (plus an additional 10 GB if managing non-windows endpoints). a) Click Browse. b) Define the desired file path using either the Look in lists or the Folder name field. c) Click OK. Step Result: The Content Storage Location field reflects your changes. 21.Click Next. Step Result: The Proxy Settings page opens. Note: Refer to the : Requirements Guide ( for a complete list of proxy types that EMSS supports. Figure 18: Proxy Settings Page Note: If one or both of the storage directories defined on the Destination Location page does not contain the recommended available disk space, the Proxy Settings page does not immediately open. Rather, a dialog that lets you redefine the storage directories will open. Then after redefining the storage directories, the Proxy Settings page will open
60 22.If your network uses a proxy server to access the Internet, select the A proxy server is required check box and type the applicable information in the following fields. Field Type Server Address The IP address of the applicable proxy server. Port The port number used for communication. Note: You can also configure EMSS to use a proxy following installation. Refer to The Service Tab in the User Guide ( for additional information on proxy communication. 23.If your network uses a proxy server to access the Internet, and that proxy requires authentication, select the Authentication required check box and type the applicable information in the following fields. Field Type Username A user name that authenticates with the proxy. Password The password associated with the user name. Confirm Password The password retyped
61 Installing 24.Click Next. Step Result: The Agent to Server Communication page opens. Figure 19: Agent to Server Communication Page 25.If you are using SSL for server and agent communication, select the Use SSL security for Patch agent communication with the server check box. Note: You must possess an SSL certificate to implement SSL communication. Implementation of SSL communication during installation is optional. This feature can be implemented following installation. 26.In the Default server identity field, type the name of your server in one of the following formats: DNS name (computername.domainname.com) Computer name (computername) IP address ( ) During agent registration, the EMSS agents use this name to identify the server. Note: If you are using SSL, the server name that you type in the field must match the server named on your certificate
62 27.Click Next. Step Result: The Installation Ready page opens. Figure 20: Installation Ready Page 28.[Optional] If you only want to install core components, clear the Automatically include all licensed modules and updates during installation check box. Note: You may use the HEAT Installation Manager after the initial installation of EMSS to install additional components. For additional information, refer to Using HEAT Installation Manager in the User Guide ( 29.Review the installation information and click Install to begin the installation of EMSS. This process may take several minutes. Important: During installation, do not attempt to access the EMSS Web site. Accessing the Web site during installation can cause installation errors. 30.After installation completes, click Finish
63 Installing 31.Acknowledge the notification that appears by clicking OK. The credentials you use to log in to the EMSS Web site for the first time are the credentials that you used when you logged into the server initially. Result: EMSS is installed and can now be accessed. After Completing This Task: Proceed to one of the following procedures based on selections made during installation. If your server will use SSL, finish Configuring SSL on page 89. If your server will not use SSL, proceed to Logging In to HEAT Endpoint Management and Security Suite on page 78. Installing (Separate EMSS and SQL Server Admins) When installing using a remote SQL Server instance in a large network environment, a special installation procedure that splits install duties between the HEAT Endpoint Management and Security Suite and the SQL Server administrator may be necessary. When installing (EMSS) using a remote SQL Server instance, the user account you use to access the SQL server instance must be assigned the sysadmin role within Microsoft SQL Server Management Studio. However, HEAT recognizes that in larger network environments, the administrator installing EMSS may not be able to obtain this role due to IT policies and procedures; only the SQL Server administrator can access the applicable SQL instance. Therefore, under these circumstances, the network administrator and SQL Server administrator must cooperate to complete EMSS installation. To install EMSS in this type of environment, the installation is broken in to three separate procedures. Table 10: Install Procedure Procedure Portion Description Beginning Installation (Part I) Performed by the EMSS administrator on the target EMSS server, this on page 64 procedure begins the product installation. During this procedure, the EMSS administrator reviews a licence agreement, defines registration information, defines the remote SQL Server location, and creates a script to modify the SQL Server instance. Creating Components on SQL Server (Part II) on page 71 Performed by the SQL Server administrator on the server hosting the applicable SQL instance, this procedure creates the user accounts necessary to operate EMSS and then runs the script created in part I. This script modifies the SQL Server instance to accommodate EMSS installation for an administrator without sysadmin rights within Microsoft SQL Server
64 Procedure Portion Description Completing Installation (Part III) on page 73 Performed by the EMSS administrator on the target EMSS server, this procedure completes EMSS installation. This procedure defines where the EMSS server and its content will be stored, whether the server will use a proxy server, and whether the server will use SSL. Beginning Installation (Part I) The administrator performs the first portion of the install procedure. At the end of this portion, the installer creates a script that is delivered to the SQL Server administrator. Prerequisites: Complete Downloading EMSS on page 23. As applicable to your network environment, you have gathered the information and completed the tasks itemized in the Server Installation Checklist on page 97. Complete Configuring SQL Server to Accept Remote Connections on page 86 If installing using SSL, complete the first portion of Configuring SSL on page 89. This first portion of this installation procedure is performed by the HEAT Endpoint Management and Security Suite (EMSS) administrator on the target EMSS server. 1. Using either a local or domain account with system administrator privileges, log in to the server on which you will install EMSS. 2. Stop or disable any AntiVirus products (such as McAfee, Trend-micro, Symantec, and so on) running on your server. Note: An AntiVirus product can prevent processes from running correctly during the installation. Therefore, to ensure a successful installation, all AntiVirus services must be stopped or disabled prior to running the EMSS installer. 3. Double-click the EMSS installer at the location defined during the download. Step Result: The EMSS InstallShield Wizard opens and begins extracting files. This process may take several minutes. 4. If prompted, install prerequisites and reboot your server. The installer reopens by itself after the reboot. 5. Click Next. Step Result: The License Agreement page opens. Tip: Click Print for a hard copy of the license agreement. 6. Review the License Agreement and select the I accept the terms of the license agreement option
65 Installing 7. Click Next. Step Result: The Customer Information page opens. Figure 21: Customer Information Page 8. Type the applicable information in the following fields: Field Description Company Name Your company name. Serial Number Your EMSS serial number. Note: Your serial number is two groups of eight alphanumeric characters. Letters are not case sensitive. If you cannot locate your serial number, obtain it by contacting the HEAT Sales Support Tip: Retain your serial number following installation, as it is necessary if a reinstall of the EMSS server is needed
66 9. Click Next. A new page or dialog opens. Page/Dialog Step If the Question dialog opens: Click Yes to start network discovery services. The following services are necessary to use discovery features within EMSS: If the Required IIS Features page opens: DNS Client Function Discovery Resource Location SSDP Discover UPnP Device Host Your server does not have the required IIS features installed. Click Install Features to install the features and proceed. Note: On Windows Server 2008, the default installation of IIS lacks components necessary for EMSS. The EMSS installer installs the following IIS components if not present: Static Content Default Document HTTP Errors ASP.NET.NET Extensibility ASP ISAPI Extensions ISAPI Filters Basic Authentication Windows Authentication Static Content Compression Dynamic Content Compression
67 Installing Page/Dialog Step If the System Requirements page opens: Your server does not meet the minimum installation requirements. If you receive only system requirement warnings, you may proceed with installation by clicking Next. HEAT recommends resolving warnings before proceeding with installation. Note: When installing on a virtual platform you will likely receive a warning about the CPU requirements since the installer is unable to identify the processor in a virtual environment. If you receive any system requirement failures, you must cancel the installation, resolve these failures, and then restart installation. Tip: Click View all Failures/Warnings for detailed information about prerequisite status deficiencies. If the Service Accounts page opens: Proceed to the next step. 10.Create the Web client account and server accounts that EMSS will use. Important: Preexisting accounts or domain accounts cannot be used for this installation procedure. a) b) c) d) e) f) [Optional] Edit the Web Client Account Username field. In the Web Client Account Password field, type the desired password. In the Web Client Account Confirm password field, retype the password. [Optional] Edit the Service Account Username field. In the Service Account Password field, type the desired password. In the Service Account Confirm password field, retype the password. Note: HEAT recommends using the default account user names the installation creates
68 11.Click Next. If required, acknowledge the creation of new accounts by clicking OK. Step Result: The SQL Server Instance Page opens. Figure 22: SQL Server Instance Page 12.Ensure the Connect to an existing SQL Server instance option is selected
69 Installing 13.Click Next. Step Result: The SQL Server and Instance page opens. Figure 23: SQL Server and Instance Page (No Local Options) Important: If Server Location options are available from this page, you are performing the wrong procedure. Instead, perform Installing Using an Existing SQL Server Instance (Either Locally or Remotely) on page Type the name (not the IP address) of the server hosting the remote SQL Server instance in the Server name field. 15.Based on the SQL Server instance you are using, select a SQL Server Instance option. Select one of the following options. Option Steps To use a default SQL Server instance: Select the Default instance option. To use a named SQL Server instance: 1. Select the Named instance option. 2. Type the instance name in the Named instance field
70 16.Click Next. Step Result: The SQL Server Authentication page opens. Figure 24: SQL Server Authentication Page 17.Click Next. Step Result: The credentials provided do not have sufficient privileges to continue dialog opens. Figure 25: Insufficient Credentials Dialog 18.Note where the script is located and click Close. 19.Leave the installer open on its current page. You will continue from this point during the last portion of the procedure
71 Installing 20.Deliver the script to your SQL Server administrator. After Completing This Task: Have your SQL Server administrator complete Creating Components on SQL Server (Part II) on page 71. Creating Components on SQL Server (Part II) The SQL Server administrator performs this portion of the install procedure, which installs components on the SQL Server instance necessary for to function. These components are installed via the script your administrator delivers. Prerequisites: Complete Configuring SQL Server to Accept Remote Connections on page 86. Complete Configuring Windows Firewall for SQL Server Instance Access on page 88. Obtain the script created by the (EMSS) installation from your network EMSS administrator and ensure it is on your SQL Server. Review the script to ensure it coincides with your IT department's policies and procedures. This second portion of the installation procedure is performed by the SQL Server administrator on your existing remote instance of SQL Server. Tip: If you have any questions and/or require additional assistance, contact HEAT support at heatsoftware.com/support. 1. Log in to your SQL Server using an account with administrative privileges. This account should also be assigned the sysadmin server role within Microsoft SQL Server Management Studio. 2. Create three user accounts. Important: Preexisting accounts or domain accounts cannot be used for this installation procedure. The first account you will create is identical to the user account used to begin the installation of EMSS. This account will be granted a login to the EMSS databases and assigned the db_owner role within Microsoft SQL Server Mangement Studio. The second and third accounts created are the Web client account and the service account. These accounts are used to operate components critical to EMSS. Important: The credentials for each of these accounts must match their respective accounts on the EMSS target server. Consult your network administrator for the credentials for each account. If these accounts are not identical, EMSS will not function correctly. Complete the following substeps to create the account: a) Select Start > Administrative Tools > Computer Management. Step Result: The Computer Management dialog opens
72 b) Expand the directory tree structure to Users (Computer Mangement [local] > System Tools > Local Users and Groups > Users). c) Right-click Users and select New User. Step Result: The New User dialog opens. Figure 26: New User Dialog d) Create a user account identical to the user account used to begin installation of EMSS. In the User name field, type the applicable user name. In the Password field, type the applicable password. In the Confirm password field, retype the password. Note: Consult your EMSS administrator to obtain these credentials. e) Clear the User must change password at next logon check box. f) Select the Password never expires check box. g) Click Create. Step Result: The user account is created. h) Repeat substeps d though g to create the Web client account. i) Repeat substeps d though g to create the service account. j) Click Close. 3. Select Start > Run. 4. In the field, type cmd
73 Installing 5. Click OK. Step Result: A command prompt opens. 6. From the command prompt, type sqlcmd -SSERVERNAME\INSTANCENAME -E -ifilepath \PreInstallDBAscript.sql -k1>c:\preinstalldbascript_out.txt. Note: Remember the following information when entering this command at the prompt: All characters in the command are case sensitive. When typing SERVERNAME\INSTANCENAME, the slash and instance name are not necessary if the applicable instance is a default instance. The -E command instructs sqlcmd to connect to the SQL Server using a trusted connection. The -i command defines where to locate the script to execute. If this command is executed from the directory where PreInstallDBAScript.sql is located, then the file path is not necessary; otherwise, the full file path must be defined. The -k1 command instructs sqlcmd to remove any control characters found in the input file. Result: The following databases are created: PLUS Patch Management Database PLUS_Staging Content Replication Database SCM Security Configuration Management Database STAT_Guardian Network Discovery/Agent Deployment Database UPCCommon Endpoint Management Platform Database The modifications necessary for your EMSS administrator to complete installation of EMSS are finished. After Completing This Task: Have your EMSS administrator complete Completing Installation (Part III) on page 73. Completing Installation (Part III) The administrator performs this portion of the install procedure, which completes installation of the. The final portion of the installation procedure is performed by the HEAT Endpoint Management and Security Suite (EMSS) administrator on your target EMSS server. Tip: If you have any questions and/or require additional assistance, contact HEAT support at heatsoftware.com/support. 1. Ensure Windows Authentication is selected
74 2. Click Next. A new page opens. Page Steps If the Destination Location page opens: Click Next and proceed to the next step. If the SQL Server Configuration Requirements page opens: The pre-installed instance of SQL Server is not configured to work with EMSS. If you only receive SQL Server configuration requirement informationals or warnings, click Next to continue (the EMSS installation will automatically reconfigure SQL Server). Proceed to the next step. If you receive any SQL Server configuration requirement failures, you must cancel the installation, resolve the failures, and then proceed with the installation. Tip: Click View Configuration Detail for detailed information about SQL Server configuration status requirements. 3. [Optional] Change the EMSS installation location. a) Click Browse. b) Define the desired file path using either the Look in lists or the Folder name field. c) Click OK. Step Result: The Installation Folder field reflects your changes. 4. [Optional] Change the EMSS content storage location. The content storage location is the location where patches and other content items are downloaded. HEAT recommends allocating at least 32 GB of storage space to content (plus an additional 10 GB if managing non-windows endpoints). a) Click Browse. b) Define the desired file path using either the Look in lists or the Folder name field. c) Click OK. Step Result: The Content Storage Location field reflects your changes
75 Installing 5. Click Next. Step Result: The Proxy Settings page opens. Note: Refer to the : Requirements Guide ( for a complete list of proxy types that EMSS supports. Figure 27: Proxy Settings Page Note: If one or both of the storage directories defined on the Destination Location page does not contain the recommended available disk space, the Proxy Settings page does not immediately open. Rather, a dialog that lets you redefine the storage directories will open. Then after redefining the storage directories, the Proxy Settings page will open. 6. If your network uses a proxy server to access the Internet, select the A proxy server is required check box and type the applicable information in the following fields. Field Type Server Address The IP address of the applicable proxy server
76 Field Type Port The port number used for communication. Note: You can also configure EMSS to use a proxy following installation. Refer to The Service Tab in the User Guide ( for additional information on proxy communication. 7. If your network uses a proxy server to access the Internet, and that proxy requires authentication, select the Authentication required check box and type the applicable information in the following fields. Field Type Username A user name that authenticates with the proxy. Password The password associated with the user name. Confirm Password The password retyped. 8. Click Next. Step Result: The Agent to Server Communication page opens. Figure 28: Agent to Server Communication Page
77 Installing 9. If you are using SSL for server and agent communication, select the Use SSL security for Patch agent communication with the server check box. Note: You must possess an SSL certificate to implement SSL communication. Implementation of SSL communication during installation is optional. This feature can be implemented following installation. 10.In the Default server identity field, type the name of your server in one of the following formats: DNS name (computername.domainname.com) Computer name (computername) IP address ( ) During agent registration, the EMSS agents use this name to identify the server. Note: If you are using SSL, the server name that you type in the field must match the server named on your certificate. 11.Click Next. Step Result: The Installation Ready page opens. Figure 29: Installation Ready Page
78 12.[Optional] If you only want to install core components, clear the Automatically include all licensed modules and updates during installation check box. Note: You may use the HEAT Installation Manager after the initial installation of EMSS to install additional components. For additional information, refer to Using HEAT Installation Manager in the User Guide ( 13.Review the installation information and click Install to begin the installation of EMSS. This process may take several minutes. Important: During installation, do not attempt to access the EMSS Web site. Accessing the Web site during installation can cause installation errors. 14.After installation completes, click Finish. Result: EMSS is installed and can now be accessed. After Completing This Task: Proceed to one of the following procedures based on selections made during installation. If your server will use SSL, finish Configuring SSL on page 89. If your server will not use SSL, proceed to Logging In to HEAT Endpoint Management and Security Suite on page 78. Logging In to After installing, log in to begin configuring the system. Prerequisites: One of the following Web browsers: Microsoft Internet Explorer Mozilla Firefox 31 Extended Support Release You can access the console from any endpoint within your network. Note: When accessing the EMSS console using a Web browser with high security settings enabled, the following message may display: Scripting must be enabled to display this application properly. In this event, HEAT recommends adding the EMSS Web address as a trusted site in your browser settings to view the Web console. 1. Open your Web browser
79 Installing 2. In your browser s address bar, type the EMSS URL (http[s]://serverurl) and press ENTER. Tip: You can also use the server IP address. Step Result: A dialog prompting you for credentials opens. 3. Type your user name in the User name field. When logging in for the first time, type the user name of the Windows user account used to install EMSS. You can use additional user names after adding new user profiles to EMSS. If logging in using a domain account, type the name in the following format: DOMAIN\Username. 4. Type your password in the Password field. 5. Click OK. Result: EMSS opens to the Home page and launches the Application Setup Manager. After Completing This Task: Complete Setting Up on page 79.Setting Up HEAT Endpoint Management and Security Suite on page 79 Setting Up Following installation and initial log in, the Application Setup Manager dialog opens. This dialog appears only once, the first time you log in to and you use it to configure basic options within the system. Prerequisites: Complete (EMSS) installation and open the Web console in your browser. You cannot reopen this dialog following its completion. However, you can access these settings from various EMSS pages. 1. Log in to EMSS. For additional information, refer to Logging In to HEAT Endpoint Management and Security Suite on page 78. Step Result: EMSS opens and the Application Setup Manager displays. This dialog only appears the first time EMSS is opened. 2. Ensure the Customer Info tab is selected. 3. Type the applicable information in the following fields. Field Description First name Your first name. Last name Your last name
80 Field Description Company name Your company name. The company name specified during installation appears by default but can be edited. 4. Click Apply. 5. [Optional] Select the check boxes associated with the languages you want to receive content in (Patch and Remediation only). Each content item available in EMSS may be available in multiple versions for different languages. 6. Click Apply. 7. Select the Uninstall Password tab. 8. Define the global agent uninstall password. a) In the Global uninstall password field, type the desired password. b) In the Confirm password field, retype the password. This password can be used to manually uninstall EMSS agents and should be kept confidential. Tip: Following installation, you can change the global uninstall password. For additional information on how to change the password outside the Application Setup Manager, refer to Defining the Global Uninstall Password in the User Guide ( 9. Click Apply. 10.[Optional] Select the Notifications tab. 11.[Optional] Define the information used for notifications. notifications are alerts sent by EMSS when certain system events occur. Type the applicable information in the following fields. Field Description SMTP Host The local SMTP mail host name. EMSS uses your corporate Internet (SMTP) mail server. From address The address used when the system sends notifications. To address An address you use to receive system notifications. Important: When upgrading EMSS via a fresh installation, you must reconfigure your notifications after installing your licensed server modules. For additional details regarding Notifications, refer to The Notifications Page in the HEAT Endpoint Management and Security Suite User Guide (
81 Installing 12.Click Apply. 13.[Optional] Select the Install an Agent tab. 14.[Optional] Select the Automatically install an agent on the server check box to install an agent on the server. a) Select the check boxes of the applicable modules. Selecting these modules activates agent functionality associated with the module. 15.Click Apply. Step Result: Your initial settings are applied. 16.Click Close. Result: Initial configuration is complete. You are now ready to begin monitoring your network with EMSS
82 - 82 -
83 Appendix A Configuring Remote SQL Server Instances In this appendix: Creating Remote Accounts Configuring SQL Server to Accept Remote Connections Configuring Windows Firewall for SQL Server Instance Access If you elect to install HEAT Endpoint Management and Security Suite using a remote instance of SQL Server, you must first create two user accounts on the server hosting the instance (provided you are not using preexisting accounts for your installation). Additionally, you must also configure your instance (and, if in place, its Windows Firewall) to accept remote connections from the server that will host HEAT Endpoint Management and Security Suite. Procedures to configure remote instances of SQL Server are provided, as well as a procedure to create the necessary user accounts. Creating Remote Accounts When installing using a remote instance of SQL server, you must first create two user accounts on the server hosting your instance: a Web client account and a service account. uses these accounts to operate components critical to the system. Without these accounts, HEAT Endpoint Management and Security Suite will be unable to access the remote SQL Server. Create these accounts on the server hosting your SQL Server instance. Note: If using domain accounts, these accounts do not have to be created locally. However, any domain account used as the service account must be added to the database server's administrators group. To use a domain account as a service account, complete this task, skipping steps Log in to the server hosting your SQL Server instance using either a local or domain user account with system administrator privileges. If your SQL Server instance uses mixed mode authentication, ensure that the user account you log in with supports SQL Server login. 2. Open the Computer Management dialog. a) Open Windows Control Panel
84 b) Open Administrative Tools. c) Open Computer Management. Step Result: The Computer Management dialog opens. 3. Expand the tree to the Users folder (System Tools > Local Users and Groups > Users). 4. Right-click the Users folder. 5. Select New User. Step Result: The New User dialog opens. Figure 30: New User Dialog 6. In the User name field, type the desired Web client account name (or service account name). HEAT recommends clientadmin for the Web client account, and serviceadmin for the service account. 7. In the Password field, type the desired password. 8. In the Confirm Password field, retype the Password. 9. Ensure the User must change password at next logon check box is cleared. Important: When creating these accounts, failure to clear the User must change password at next logon will deny you access to the EMSS Web site following installation. 10.Select the Password never expires check box. 11.Click Create. Step Result: The Web client account is created
85 Configuring Remote SQL Server Instances 12.Repeat steps 5 through 11 to create the service account. Step Result: The service account is created. 13.Click Close. 14.Expand the directory tree structure to the Groups folder (System Tools > Local Users and Groups > Groups). 15.In the main pane, double-click Administrators. Step Result: The Administrators Properties dialog opens. Figure 31: Administrators Properties Dialog
86 16.Click Add. Step Result: The Select Users dialog opens. Figure 32: Select Users Dialog 17.In the Enter the object names to select dialog, type your service account name. 18.Click OK. Step Result: The service account is added to the Administrators group. 19.Click OK. Result: The Web client and service accounts are created. Configuring SQL Server to Accept Remote Connections When configuring for use with a remote SQL Server instance, you must configure that instance to accept remote connections. Perform this task on the server hosting the SQL Server instance you want to use with HEAT Endpoint Management and Security Suite (EMSS)
87 Configuring Remote SQL Server Instances 1. Using the Start menu or the Start screen, open SQL Server Configuration Manager. Step Result: SQL Server Configuration Manager opens. Figure 33: SQL Server Configuration Manager 2. Expand the tree to Protocols for EMSSSQLInstanceName. Example: For example, for the default EMSS SQL install, select SQL Server Configuration Mnager (Local) > SQL Server Network Configuration > Protocols for UPC. 3. Enable the TCP/IP protocol for your instance. a) From the main pane, double-click TCP/IP. b) Set Enabled to Yes. 4. Configure the TCP/IP protocol to allow connection from your HEAT EMSS Server. a) b) c) d) e) f) From the TCP/IP Properties dialog, select the IP Addresses tab. From an unused IP node (IP1, IP2, or so on), set Active to Yes. Set Enabled to Yes. Set the IP Address to the address of your HEAT EMSS Server. Click OK. Click OK to acknowledge that the service needs to be restarted. 5. If installing EMSS to a named instance of SQL Server, ensure the SQL Server Browser Service is running. a) b) c) d) e) From the tree, select SQL Server Services. From the main pane, double-click the SQL Server Browser. Ensure the Service tab is selected. Ensure that Automatic is selected from the Start Mode list. Click OK
88 f) From the main pane, right-click SQL Server Browser. g) Select Restart (or Start if Restart is unavailable). 6. From the tree, select SQL Server Configuration Manager (Local) > SQL Server Services. 7. From the main pane, right-click SQL Server (EMSSSQLInstanceName) and select Restart. Example: Restart SQL Server (UPC). 8. Close Sql Server Configuration Manager. Result: Your SQL Server instance is ready for use with EMSS. Proceed with the installation procedure (provided your SQL Server instance is not behind a Windows Firewall). After Completing This Task: If your SQL server instance is behind a Windows Firewall, complete Configuring Windows Firewall for SQL Server Instance Access on page 88. Configuring Windows Firewall for SQL Server Instance Access If you are configuring for use with a remote SQL Server instance, you must configure your SQL Server's Windows Firewall to allow access to HEAT Endpoint Management and Security Suite (if your SQL Server has Windows Firewall enabled). Configure your SQL Server firewall according to your SQL server instance version. Complete the steps listed at Configure a Windows Firewall for Database Engine Access ( library/ms aspx). Note: You edit your Windows Firewall settings according to your specific server operating system. The procedures available at the provided Microsoft Web sites may differ slightly when you edit your specific settings
89 Appendix B Configuring Your Server to use SSL In this appendix: Configuring SSL During installation of the HEAT Endpoint Management and Security Suite server, you can configure HEAT Endpoint Management and Security Suite to use SSL for server to agent communication after obtaining an SSL certificate from a trust provider. Obtaining a trusted SSL certificate can take several days. Therefore, HEAT recommends obtaining an SSL certificate before installing HEAT Endpoint Management and Security Suite. Certificates can be obtained from trust providers such as Verisign Inc. ( or Entrust ( Configuring SSL For security purposes, you can configure the server and agent to use SSL communication. To use SSL, assign your certificate to the HEAT Endpoint Management and Security Suite Web site. Prerequisites: You must obtain a certificate from a root certificate authority. Associate your certificate with the (EMSS) Web site in your server's Internet Information Services (IIS) Manager. Note: The first portion of this procedure is performed before installation of EMSS, and the second portion is performed following installation of EMSS. Important: If you are installing EMSS on a server that already hosts a Web site, a different procedure must be used for SSL configuration. For additional information, refer to HEAT KnowledgeBase Article 791 ( for additional guidance
90 1. If necessary, import your certificate. To import your certificate, complete the following substeps. a) Open Internet Information Services (IIS) Manager, which can be found in Administrative Tools within Control Panel. Step Result: Internet Information Services (IIS) Manager opens. b) From the tree, select your server. Figure 34: Internet Information Services (IIS) Manager
91 Configuring Your Server to use SSL c) In the main pane, scroll to the IIS section and double-click Server Certificates. Step Result: The Server Certificates page opens. Figure 35: Server Certificates Page d) Click the Import link. Step Result: The Import Certificate dialog opens. Figure 36: Import Certificate Dialog e) Click the Elipses button (... ), browse to your certificate, and click Open. You may have to edit the File name type list to see your certificate. f) Type the certificate Password
92 g) Click OK. 2. Assign the certificate to the default Web site. To assign the certificate, complete the following substeps. a) From the tree, expand to Default Web Site (Server Name > Sites > Default Web Site). b) Click the Bindings link. Step Result: The Site Bindings dialog opens. c) Click Add. Step Result: The Add Site Binding dialog opens. Figure 37: Add Site Binding Dialog d) e) f) g) From the Type list, select https. From the SSL certificate list, select your certificate. Click OK. Click Close. 3. Complete one of the following EMSS installation procedures listed in Selecting an Installation Method on page 25. While installing EMSS, select the Use SSL security for Patch agent communication with the server check box. Note: Name resolution of the server, endpoints, and the root certificate authority is required to use SSL. 4. Assign the certificate to the EMSS Web site. Complete the following substeps to assign the certificate. a) Open Internet Information Services (IIS) Manager, which can be found in Administrative Tools within Control Panel. Step Result: Internet Information Services (IIS) Manager opens. b) From the tree, select HEAT Web site (Server Name > Sites > HEAT)
93 Configuring Your Server to use SSL c) Click the Bindings link. Step Result: The Site Bindings dialog opens. d) Click Add. Step Result: The Add Site Binding dialog opens. Figure 38: Add Site Binding Dialog e) f) g) h) From the Type list, select https. From the SSL certificate list, select your certificate. Click OK. Click Close. 5. Configure the Web site to accept only SSL connections. a) b) c) d) In the main pane, scroll to the IIS section. Double-click SSL Settings. Select the Require SSL check box. Click Apply. Result: Your server is now configured for SSL communication. After Completing This Task: Complete Logging In to on page 78. Complete Setting Up on page 79. After you have completed setup, edit your global configuration policy set and ensure Use SSL for agent to server communication to True. For additional information, refer to Secure Your Server With SSL in the User Guide ( portal.lumension.com)
94 - 94 -
95 Appendix C Upgrading from Previous Installations HEAT routinely releases updates that upgrade previous product installations. Install these new versions to take advantage of new features. Rather than deleting the previous product installation, you can upgrade the existing installation to the new version. For more information, see the HEAT Endpoint Management and Security Suite: Upgrade Guide (
96 - 96 -
97 Appendix D Installation Checklist In this appendix: Server Installation Checklist For your convenience, an installation checklist is provided that itemizes information and tasks. Server Installation Checklist This checklist itemizes the information you will need and tasks you will need to complete when installing the server. Prior to installing (EMSS), you must gather and confirm the following information: You target server has the required service packs installed for its operating system. For more information, see Supported Operating Systems on page 9. Your target computer meets or exceeds the hardware requirements listed in Combined EMSS Application and Database Server on page 18. Your server is not a Domain Controller. Your server has all required software installed: Software Requirements Microsoft SQL Server SQL Server Requirements on page 13 Microsoft Internet Information Services IIS Requirements on page 14 Web Browser Web Browser Requirements on page 12 Ensure the target server uses one of supported locales and browser languages listed in Supported Languages and Locales on page 10. Your EMSS server meets network requirements listed in Network Requirements on page
98 If your server is a member of a domain, the default security policies are in effect. Warning: Avoid changing any Domain Group Policy object (GPO) settings that could overwrite the Log on as a service or Impersonate a client after authentication settings within the User Rights Assignments area of your local server. Overwriting these settings causes critical SQL Server and EMSS settings to be ignored and may result in system failure. Your server DNS host name is: Your EMSS serial number is: - Your target system is connected to the Internet. If you are using SSL, a valid SSL Web certificate has been obtained. Note: If you are using SSL, you need to obtain a valid Web certificate, from a trust provider such as Verisign Inc. ( or Entrust ( prior to installing EMSS. If you are using SSL, you have started the first portion of Configuring SSL on page 89 (the second portion is completed after installation). If a proxy server will be used, you know the proxy server s name, IP address, port, user name, and password. Name: IP address: Port: User name: Password: If you are using a preexisting instance of SQL Server, the instance is set to one of the following collation values: SQL_Latin1_General_CP1_CI_AS Latin1_General_CI_AS If you are using a preexisting instance of SQL Server, whether local or remote, the operating system of the server hosting the instance is set to an English language locale. If you are using a remote SQL instance, the instance is configured to accept remote connections. For additional information, refer to Configuring SQL Server to Accept Remote Connections on page 86. If you are using a remote SQL instance, and that instance is behind a firewall, the firewall is configured to allow the EMSS server access. For additional information, refer to Configuring Windows Firewall for SQL Server Instance Access on page 88. Your local SMTP mail host name is:
Quick Install Guide. Lumension Endpoint Management and Security Suite 7.1
Quick Install Guide Lumension Endpoint Management and Security Suite 7.1 Lumension Endpoint Management and Security Suite - 2 - Notices Version Information Lumension Endpoint Management and Security Suite
Server Installation Guide ZENworks Patch Management 6.4 SP2
Server Installation Guide ZENworks Patch Management 6.4 SP2 02_016N 6.4SP2 Server Installation Guide - 2 - Notices Version Information ZENworks Patch Management Server Installation Guide - ZENworks Patch
Installation Guide for Pulse on Windows Server 2008R2
MadCap Software Installation Guide for Pulse on Windows Server 2008R2 Pulse Copyright 2014 MadCap Software. All rights reserved. Information in this document is subject to change without notice. The software
Installation Guide for Pulse on Windows Server 2012
MadCap Software Installation Guide for Pulse on Windows Server 2012 Pulse Copyright 2014 MadCap Software. All rights reserved. Information in this document is subject to change without notice. The software
http://docs.trendmicro.com
Trend Micro Incorporated reserves the right to make changes to this document and to the products described herein without notice. Before installing and using the product, please review the readme files,
formerly Help Desk Authority 9.1.3 Upgrade Guide
formerly Help Desk Authority 9.1.3 Upgrade Guide 2 Contacting Quest Software Email: Mail: Web site: [email protected] Quest Software, Inc. World Headquarters 5 Polaris Way Aliso Viejo, CA 92656 USA www.quest.com
DameWare Server. Administrator Guide
DameWare Server Administrator Guide About DameWare Contact Information Team Contact Information Sales 1.866.270.1449 General Support Technical Support Customer Service User Forums http://www.dameware.com/customers.aspx
NTP Software File Auditor for Windows Edition
NTP Software File Auditor for Windows Edition An NTP Software Installation Guide Abstract This guide provides a short introduction to installation and initial configuration of NTP Software File Auditor
AMS Suite: Machinery Health Manager
AMS Suite: Machinery Health Manager Version 5.61 Software Installation Guide User Guide MHM-97402, Rev 23 November 2014 Copyright 2014 by Emerson Process Management. All rights reserved. No part of this
Symantec Backup Exec 2010 R2. Quick Installation Guide
Symantec Backup Exec 2010 R2 Quick Installation Guide 20047221 The software described in this book is furnished under a license agreement and may be used only in accordance with the terms of the agreement.
Core Protection for Virtual Machines 1
Core Protection for Virtual Machines 1 Comprehensive Threat Protection for Virtual Environments. Installation Guide e Endpoint Security Trend Micro Incorporated reserves the right to make changes to this
Backup Exec 15. Quick Installation Guide
Backup Exec 15 Quick Installation Guide 21344987 Documentation version: 15 PN: 21344987 Legal Notice Copyright 2015 Symantec Corporation. All rights reserved. Symantec, the Symantec Logo, the Checkmark
http://docs.trendmicro.com
Trend Micro Incorporated reserves the right to make changes to this document and to the products described herein without notice. Before installing and using the product, please review the readme files,
NSi Mobile Installation Guide. Version 6.2
NSi Mobile Installation Guide Version 6.2 Revision History Version Date 1.0 October 2, 2012 2.0 September 18, 2013 2 CONTENTS TABLE OF CONTENTS PREFACE... 5 Purpose of this Document... 5 Version Compatibility...
XenClient Enterprise Synchronizer Installation Guide
XenClient Enterprise Synchronizer Installation Guide Version 5.1.0 March 26, 2014 Table of Contents About this Guide...3 Hardware, Software and Browser Requirements...3 BIOS Settings...4 Adding Hyper-V
Symantec AntiVirus Corporate Edition Patch Update
Symantec AntiVirus Corporate Edition Patch Update Symantec AntiVirus Corporate Edition Update Documentation version 10.0.1.1007 Copyright 2005 Symantec Corporation. All rights reserved. Symantec, the Symantec
NETWRIX EVENT LOG MANAGER
NETWRIX EVENT LOG MANAGER QUICK-START GUIDE FOR THE ENTERPRISE EDITION Product Version: 4.0 July/2012. Legal Notice The information in this publication is furnished for information use only, and does not
Sharp Remote Device Manager (SRDM) Server Software Setup Guide
Sharp Remote Device Manager (SRDM) Server Software Setup Guide This Guide explains how to install the software which is required in order to use Sharp Remote Device Manager (SRDM). SRDM is a web-based
Important. Please read this User s Manual carefully to familiarize yourself with safe and effective usage.
Important Please read this User s Manual carefully to familiarize yourself with safe and effective usage. About This Manual This manual describes how to install and configure RadiNET Pro Gateway and RadiCS
Enterprise Manager. Version 6.2. Installation Guide
Enterprise Manager Version 6.2 Installation Guide Enterprise Manager 6.2 Installation Guide Document Number 680-028-014 Revision Date Description A August 2012 Initial release to support version 6.2.1
StarWind iscsi SAN: Configuring Global Deduplication May 2012
StarWind iscsi SAN: Configuring Global Deduplication May 2012 TRADEMARKS StarWind, StarWind Software, and the StarWind and StarWind Software logos are trademarks of StarWind Software that may be registered
Setting Up a Unisphere Management Station for the VNX Series P/N 300-011-796 Revision A01 January 5, 2010
Setting Up a Unisphere Management Station for the VNX Series P/N 300-011-796 Revision A01 January 5, 2010 This document describes the different types of Unisphere management stations and tells how to install
Microsoft Dynamics GP. Workflow Installation Guide Release 10.0
Microsoft Dynamics GP Workflow Installation Guide Release 10.0 Copyright Copyright 2008 Microsoft Corporation. All rights reserved. Complying with all applicable copyright laws is the responsibility of
SMART Vantage. Installation guide
SMART Vantage Installation guide Product registration If you register your SMART product, we ll notify you of new features and software upgrades. Register online at smarttech.com/registration. Keep the
Dell One Identity Cloud Access Manager 7.0.2. Installation Guide
Dell One Identity Cloud Access Manager 7.0.2 2014 Dell Inc. ALL RIGHTS RESERVED. This guide contains proprietary information protected by copyright. The software described in this guide is furnished under
Microsoft SQL Server 2014. Installation Guide
Microsoft SQL Server 2014 Installation Guide Notices 2015 XMPie Inc. All rights reserved. U.S. Patents 6948115, 7406194, 7548338, 7757169 and pending patents. JP Patent 4406364B and pending patents. Microsoft
Introduction and Overview
Inmagic Content Server Workgroup 10.00 Microsoft SQL Server 2005 Express Edition Installation Notes Introduction and Overview These installation notes are intended for the following scenarios: 1) New installations
Interworks. Interworks Cloud Platform Installation Guide
Interworks Interworks Cloud Platform Installation Guide Published: March, 2014 This document contains information proprietary to Interworks and its receipt or possession does not convey any rights to reproduce,
StruxureWare Power Monitoring 7.0.1
StruxureWare Power Monitoring 7.0.1 Installation Guide 7EN02-0308-01 07/2012 Contents Safety information 5 Introduction 7 Summary of topics in this guide 7 Supported operating systems and SQL Server editions
User Manual. Onsight Management Suite Version 5.1. Another Innovation by Librestream
User Manual Onsight Management Suite Version 5.1 Another Innovation by Librestream Doc #: 400075-06 May 2012 Information in this document is subject to change without notice. Reproduction in any manner
Installing and Configuring vcenter Multi-Hypervisor Manager
Installing and Configuring vcenter Multi-Hypervisor Manager vcenter Server 5.1 vcenter Multi-Hypervisor Manager 1.1 This document supports the version of each product listed and supports all subsequent
4.0 SP1 (4.0.1.0) November 2014 702P03296. Xerox FreeFlow Core Installation Guide: Windows Server 2008 R2
4.0 SP1 (4.0.1.0) November 2014 702P03296 Installation Guide: Windows Server 2008 R2 2014 Xerox Corporation. All rights reserved. Xerox, Xerox and Design, FreeFlow, and VIPP are trademarks of Xerox Corporation
Preparing Your Network for an MDsuite Installation
Preparing Your Network for an MDsuite Installation Professional Data Services 1632 East 23 rd Avenue Hutchinson, KS 67502 Toll-free: 800.875.0480 Fax: 858.486.5493 www.mdsuite.com Introduction This document
Dell Statistica 13.0. Statistica Enterprise Installation Instructions
Dell Statistica 13.0 2015 Dell Inc. ALL RIGHTS RESERVED. This guide contains proprietary information protected by copyright. The software described in this guide is furnished under a software license or
File Auditor for NAS, Net App Edition
File Auditor for NAS, Net App Edition Installation Guide Revision 1.2 - July 2015 This guide provides a short introduction to the installation and initial configuration of NTP Software File Auditor for
How To Manage Storage With Novell Storage Manager 3.X For Active Directory
www.novell.com/documentation Installation Guide Novell Storage Manager 4.1 for Active Directory September 10, 2015 Legal Notices Condrey Corporation makes no representations or warranties with respect
Synchronizer Installation
Synchronizer Installation Synchronizer Installation Synchronizer Installation This document provides instructions for installing Synchronizer. Synchronizer performs all the administrative tasks for XenClient
Installing and Configuring WhatsUp Gold
Installing and Configuring WhatsUp Gold This guide provides information about installing and configuring WhatsUp Gold v14.2, including instructions on how to run the WhatsUp web interface through an Internet
Symantec Backup Exec TM 11d for Windows Servers. Quick Installation Guide
Symantec Backup Exec TM 11d for Windows Servers Quick Installation Guide September 2006 Symantec Legal Notice Copyright 2006 Symantec Corporation. All rights reserved. Symantec, Backup Exec, and the Symantec
About Recovery Manager for Active
Dell Recovery Manager for Active Directory 8.6.1 May 30, 2014 These release notes provide information about the Dell Recovery Manager for Active Directory release. About Resolved issues Known issues System
Installation Guide Supplement
Installation Guide Supplement for use with Microsoft ISA Server and Forefront TMG Websense Web Security Websense Web Filter v7.5 1996 2010, Websense Inc. All rights reserved. 10240 Sorrento Valley Rd.,
Agent Install Guide. New Boundary Prism Patch Manager 7.0 SP1
Agent Install Guide -2- Notices Version Information New Boundary Prism Patch Manager Agent Install Guide - New Boundary Prism Patch Manager Version 7.0 SP1 Released: April 2010 Document Number: 02_017_7.0
Networking Best Practices Guide. Version 6.5
Networking Best Practices Guide Version 6.5 Summer 2010 Copyright: 2010, CCH, a Wolters Kluwer business. All rights reserved. Material in this publication may not be reproduced or transmitted in any form
Embarcadero Performance Center 2.7 Installation Guide
Embarcadero Performance Center 2.7 Installation Guide Copyright 1994-2009 Embarcadero Technologies, Inc. Embarcadero Technologies, Inc. 100 California Street, 12th Floor San Francisco, CA 94111 U.S.A.
PHD Virtual Backup for Hyper-V
PHD Virtual Backup for Hyper-V version 7.0 Installation & Getting Started Guide Document Release Date: December 18, 2013 www.phdvirtual.com PHDVB v7 for Hyper-V Legal Notices PHD Virtual Backup for Hyper-V
EntraPass WebStation. Installation Manual DN1864-1005
EntraPass WebStation Installation Manual EntraPass WebStation Installation Manual Table of Contents General Information...1 Copyright Info...1 Technical Support...1 Overview...2 Introduction... 2 Description...
Getting Started with ESXi Embedded
ESXi 4.1 Embedded vcenter Server 4.1 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To check for more recent
http://docs.trendmicro.com/en-us/enterprise/trend-micro-endpoint-applicationcontrol.aspx
Trend Micro Incorporated reserves the right to make changes to this document and to the product described herein without notice. Before installing and using the product, review the readme files, release
Nexio Connectus with Nexio G-Scribe
Nexio Connectus with Nexio G-Scribe 2.1.2 3/20/2014 Edition: A 2.1.2 Publication Information 2014 Imagine Communications. Proprietary and Confidential. Imagine Communications considers this document and
Kaseya 2. Installation guide. Version 7.0. English
Kaseya 2 Kaseya Server Setup Installation guide Version 7.0 English September 4, 2014 Agreement The purchase and use of all Software and Services is subject to the Agreement as defined in Kaseya s Click-Accept
Secret Server Installation Windows 8 / 8.1 and Windows Server 2012 / R2
Secret Server Installation Windows 8 / 8.1 and Windows Server 2012 / R2 Table of Contents Table of Contents... 1 I. Introduction... 3 A. ASP.NET Website... 3 B. SQL Server Database... 3 C. Administrative
Portions of this product were created using LEADTOOLS 1991-2009 LEAD Technologies, Inc. ALL RIGHTS RESERVED.
Installation Guide Lenel OnGuard 2009 Installation Guide, product version 6.3. This guide is item number DOC-110, revision 1.038, May 2009 Copyright 1992-2009 Lenel Systems International, Inc. Information
GFI Product Manual. Getting Started Guide
GFI Product Manual Getting Started Guide The information and content in this document is provided for informational purposes only and is provided "as is" with no warranty of any kind, either express or
2X SecureRemoteDesktop. Version 1.1
2X SecureRemoteDesktop Version 1.1 Website: www.2x.com Email: [email protected] Information in this document is subject to change without notice. Companies, names, and data used in examples herein are fictitious
Pearl Echo Installation Checklist
Pearl Echo Installation Checklist Use this checklist to enter critical installation and setup information that will be required to install Pearl Echo in your network. For detailed deployment instructions
User Guide. Lumension Application Scanner Tool 2.3.2. December 2013. Copyright 2011-2013, Lumension
User Guide Lumension Application Scanner Tool 2.3.2 December 2013 Copyright 2011-2013, Lumension Notices VERSION INFORMATION Lumension Application Scanner Tool 2.3.2 User Guide Released: December 2013
SOLARWINDS ORION. Patch Manager Evaluation Guide
SOLARWINDS ORION Patch Manager Evaluation Guide About SolarWinds SolarWinds, Inc. develops and markets an array of network management, monitoring, and discovery tools to meet the diverse requirements of
Kaseya Server Instal ation User Guide June 6, 2008
Kaseya Server Installation User Guide June 6, 2008 About Kaseya Kaseya is a global provider of IT automation software for IT Solution Providers and Public and Private Sector IT organizations. Kaseya's
MGC WebCommander Web Server Manager
MGC WebCommander Web Server Manager Installation and Configuration Guide Version 8.0 Copyright 2006 Polycom, Inc. All Rights Reserved Catalog No. DOC2138B Version 8.0 Proprietary and Confidential The information
About This Manual. 2 About This Manual
Ver.4.1 Important This System Guide applies to RadiNET Pro Ver. 4.1. Please read this System Guide and the User s Manual on the RadiNET Pro CD-ROM carefully to familiarize yourself with safe and effective
User Guide. Lumension Endpoint Management and Security Suite Patch and Remediation 8.0
User Guide Lumension Endpoint Management and Security Suite Patch and Remediation 8.0 Lumension Endpoint Management and Security Suite: Patch and Remediation - 2 - Notices Version Information Lumension
GFI Product Manual. Web security, monitoring and Internet access control. Administrator Guide
GFI Product Manual Web security, monitoring and Internet access control Administrator Guide The information and content in this document is provided for informational purposes only and is provided "as
Dell Recovery Manager for Active Directory 8.6. Quick Start Guide
Dell Recovery Manager for Active Directory 8.6 2014 Dell Inc. ALL RIGHTS RESERVED. This guide contains proprietary information protected by copyright. The software described in this guide is furnished
Sage 100 ERP. Installation and System Administrator s Guide
Sage 100 ERP Installation and System Administrator s Guide This is a publication of Sage Software, Inc. Version 2014 Copyright 2013 Sage Software, Inc. All rights reserved. Sage, the Sage logos, and the
Veeam Backup Enterprise Manager. Version 7.0
Veeam Backup Enterprise Manager Version 7.0 User Guide August, 2013 2013 Veeam Software. All rights reserved. All trademarks are the property of their respective owners. No part of this publication may
AIMS Installation and Licensing Guide
AIMS Installation and Licensing Guide Version 9 2603 Camino Ramon Suite 110 San Ramon, CA 94583 Toll Free: 800-609-8610 Direct: 925-217-5170 FAX: 925-217-0853 Email: [email protected] Limited Warranty
Dell SupportAssist Version 2.0 for Dell OpenManage Essentials Quick Start Guide
Dell SupportAssist Version 2.0 for Dell OpenManage Essentials Quick Start Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer.
Thinspace deskcloud. Quick Start Guide
Thinspace deskcloud Quick Start Guide Version 1.2 Published: SEP-2014 Updated: 16-SEP-2014 2014 Thinspace Technology Ltd. All rights reserved. The information contained in this document represents the
FAS Asset Accounting FAS CIP Accounting FAS Asset Inventory SQL Server Installation & Administration Guide Version 2011.1
FAS Asset Accounting FAS CIP Accounting FAS Asset Inventory SQL Server Installation & Administration Guide Version 2011.1 2011 Sage Software, Inc. All rights reserved. Published by Sage 2325 Dulles Corner
NTP Software File Auditor for NAS, EMC Edition
NTP Software File Auditor for NAS, EMC Edition Installation Guide June 2012 This guide provides a short introduction to the installation and initial configuration of NTP Software File Auditor for NAS,
Server Software Installation Guide
Server Software Installation Guide This guide provides information on...... The architecture model for GO!Enterprise MDM system setup... Hardware and supporting software requirements for GO!Enterprise
Test Center Enterprise. ios Device Onboarding Guide
Test Center Enterprise ios Device Onboarding Guide Copyright Copyright 2012 Keynote DeviceAnywhere. All Rights Reserved. March 2012. Notice 2012 Keynote DeviceAnywhere. All rights reserved. THE INFORMATION
How to Test Out Backup & Replication 6.5 for Hyper-V
How to Test Out Backup & Replication 6.5 for Hyper-V Mike Resseler May, 2013 2013 Veeam Software. All rights reserved. All trademarks are the property of their respective owners. No part of this publication
7.5 7.5. Spotlight on Messaging. Evaluator s Guide
7.5 Spotlight on Messaging 7.5 Evaluator s Guide 2010 Quest Software, Inc. ALL RIGHTS RESERVED. This guide contains proprietary information protected by copyright. The software described in this guide
WhatsUp Gold v16.2 Installation and Configuration Guide
WhatsUp Gold v16.2 Installation and Configuration Guide Contents Installing and Configuring Ipswitch WhatsUp Gold v16.2 using WhatsUp Setup Installing WhatsUp Gold using WhatsUp Setup... 1 Security guidelines
2X Cloud Portal v10.5
2X Cloud Portal v10.5 URL: www.2x.com E-mail: [email protected] Information in this document is subject to change without notice. Companies, names, and data used in examples herein are fictitious unless otherwise
Installation Instructions Release Version 15.0 January 30 th, 2011
Release Version 15.0 January 30 th, 2011 ARGUS Software: ARGUS Valuation - DCF The contents of this document are considered proprietary by ARGUS Software, the information enclosed and any portion thereof
Abila MIP. Installation Guide
This is a publication of Abila, Inc. Version 2015.x Copyright 2014 Abila, Inc. All rights reserved. Abila, the Abila logos, and the Abila product and service names mentioned herein are registered trademarks
Team Foundation Server 2013 Installation Guide
Team Foundation Server 2013 Installation Guide Page 1 of 164 Team Foundation Server 2013 Installation Guide Benjamin Day [email protected] v1.1.0 May 28, 2014 Team Foundation Server 2013 Installation Guide
Installing CaseMap Server User Guide
Installing CaseMap Server User Guide CaseMap Server, Version 1.8 System Requirements Installing CaseMap Server Installing the CaseMap Admin Console Installing the CaseMap SQL Import Utility Testing Installation
User Guide. CTERA Agent. August 2011 Version 3.0
User Guide CTERA Agent August 2011 Version 3.0 Copyright 2009-2011 CTERA Networks Ltd. All rights reserved. No part of this document may be reproduced in any form or by any means without written permission
Installation and Configuration Guide. NetIQ Security and Compliance Dashboard
Installation and Configuration Guide NetIQ Security and Compliance Dashboard June 2011 Legal Notice NetIQ Secure Configuration Manager is covered by United States Patent No(s): 5829001, 7093251. THIS DOCUMENT
Server Installation Manual 4.4.1
Server Installation Manual 4.4.1 1. Product Information Product: BackupAgent Server Version: 4.4.1 2. Introduction BackupAgent Server has several features. The application is a web application and offers:
D&B360. Installation and Administration Guide. for Microsoft Dynamics CRM. Version 3.0
D&B360 Installation and Administration Guide for Microsoft Dynamics CRM Version 3.0 D&B360 is a trademark or registered trademark of Dun and Bradstreet, Incorporated. Other trademarks used herein are the
WhatsUp Gold v16.3 Installation and Configuration Guide
WhatsUp Gold v16.3 Installation and Configuration Guide Contents Installing and Configuring WhatsUp Gold using WhatsUp Setup Installation Overview... 1 Overview... 1 Security considerations... 2 Standard
Legal Notes. Regarding Trademarks. 2013 KYOCERA Document Solutions Inc.
Legal Notes Unauthorized reproduction of all or part of this guide is prohibited. The information in this guide is subject to change without notice. We cannot be held liable for any problems arising from
Symantec Integrated Enforcer for Microsoft DHCP Servers Getting Started Guide
Symantec Integrated Enforcer for Microsoft DHCP Servers Getting Started Guide Legal Notice Copyright 2006 Symantec Corporation. All rights reserved. Federal acquisitions: Commercial Software - Government
GFI Product Manual. Version 6.0. Getting Started Guide
GFI Product Manual Version 6.0 Getting Started Guide The information and content in this document is provided for informational purposes only and is provided "as is" with no warranty of any kind, either
Microsoft SQL Server 2008 R2 Express Edition with Advanced Services Installation Guide
Microsoft SQL Server 2008 R2 Express Edition with Advanced Services Installation Guide Notices 2011 XMPie Inc. All rights reserved. U.S. Patents 6948115, 7406194, 7548338, 7757169 and pending patents.
Password Reset Server Installation Guide Windows 8 / 8.1 Windows Server 2012 / R2
Password Reset Server Installation Guide Windows 8 / 8.1 Windows Server 2012 / R2 Last revised: November 12, 2014 Table of Contents Table of Contents... 2 I. Introduction... 4 A. ASP.NET Website... 4 B.
SC-T35/SC-T45/SC-T46/SC-T47 ViewSonic Device Manager User Guide
SC-T35/SC-T45/SC-T46/SC-T47 ViewSonic Device Manager User Guide Copyright and Trademark Statements 2014 ViewSonic Computer Corp. All rights reserved. This document contains proprietary information that
Altiris IT Analytics Solution 7.1 SP1 from Symantec User Guide
Altiris IT Analytics Solution 7.1 SP1 from Symantec User Guide Altiris IT Analytics Solution 7.1 from Symantec User Guide The software described in this book is furnished under a license agreement and
HP Business Availability Center
HP Business Availability Center for the Windows and Solaris operating systems Software Version: 8.05 Business Process Monitor Administration Document Release Date:September 2010 Software Release Date:
Installing Management Applications on VNX for File
EMC VNX Series Release 8.1 Installing Management Applications on VNX for File P/N 300-015-111 Rev 01 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright
CTERA Agent for Windows
User Guide CTERA Agent for Windows May 2012 Version 3.1 Copyright 2009-2012 CTERA Networks Ltd. All rights reserved. No part of this document may be reproduced in any form or by any means without written
ChangeAuditor. Migration Guide CA-MG-0808-470
ChangeAuditor Migration Guide CA-MG-0808-470 Copyright 2008 NetPro Computing, Inc. Disclaimer NetPro Computing, Inc. (NetPro) makes no representations or warranties, either expressed or implied, with
Agent Install Guide. Lumension Endpoint Management and Security Suite 7.0 SP1
Agent Install Guide Lumension Endpoint Management and Security Suite 7.0 SP1 Lumension Endpoint Management and Security Suite 7.0 SP1-2- Notices Version Information Lumension Endpoint Management and Security
Getting Started with Symantec Endpoint Protection
Getting Started with Symantec Endpoint Protection 20983668 Getting Started with Symantec Endpoint Protection The software described in this book is furnished under a license agreement and may be used only
NetWrix USB Blocker. Version 3.6 Administrator Guide
NetWrix USB Blocker Version 3.6 Administrator Guide Table of Contents 1. Introduction...3 1.1. What is NetWrix USB Blocker?...3 1.2. Product Architecture...3 2. Licensing...4 3. Operation Guide...5 3.1.
Metalogix Replicator. Quick Start Guide. Publication Date: May 14, 2015
Metalogix Replicator Quick Start Guide Publication Date: May 14, 2015 Copyright Metalogix International GmbH, 2002-2015. All Rights Reserved. This software is protected by copyright law and international
