Elevate your Thinking... Contents
|
|
|
- Willa Gordon
- 10 years ago
- Views:
Transcription
1
2 Elevate your Thinking... Contents Smart technology and state-of-the-art safety systems are changing the concept for elevator. Green technology, considering of the global environment, protects the future of Earth. A world-class, exquisite design increases building value. The i XEL redefines and raises your standards of elevators. Core tech Smart Technology 06 Green Technology 08 Confidence in Safety 10 Emotional Design 12 Products Entrance & Car Design 16 Ceilings & Signal Fixtures 22 Specifications Group Control Operating System 26 Installation Layout Plan & Standard Dimensions 28 Typical Entrance Layouts 30
3 ELEVATE YOUR Thinking about Tech Since its founding in 1984, Hyundai Elevator has been an industry leader in Korea with innovative technology and a pioneering mindset. The company is becoming a global leader in the elevator industry by taking action in many areas to offer advanced technology, design, safety, and environment-friendliness. The i XEL, a high-speed elevator, is an uncommon product of state-ofthe-art technology. It increases the value of high-rise buildings beyond your imagination. i. XEL I CORE TECH 04 05
4 01 Distinctive technologies available nowhere else make the XEL suitable for VIPs. SMART TECHNOLOGY We offer optimal performance and efficiency, in addition to maximum use of space, to our customers, and ensure an optimal level of comfort and the best riding experience to passengers. Enjoy the most advanced, distinctive high-speed elevator technologies of the i XEL by Hyundai Elevator. The permanent magnetic gearless traction machine First-class riding comfort The permanent magnetic gearless traction machine was developed by Hyundai Elevator. There is no vibration from the mechanism of gears. You will enjoy a comfortable, smooth riding experience as if you were riding first class. The best technology for the best building We have adopted an electric regenerative converter and high-precision control inverter drive system that optimally controls the speed of the electric motor by simultaneously and continually changing the voltage and frequency. This has resulted in the smoothest ride ever and substantially improves energy-efficiency, thus enhancing the value of a building. Advanced technology that considers even the building space Since the traction machine used for the i XEL allows for multiple arrangements, it is about 50% smaller and lighter compared to the previous induction motor. The machine occupies little space, thus allowing more space available for renting and other usage. Smart system that considers both passengers and managers More convenient services are offered based on state-of-the-art IT convergence technologies, such as the Destination Selecting System(destination floor reservation system), which reduces both wait time and unnecessary elevator operation; an artificial intelligence-based group control system that forecasts use for more efficient operation; and a computer monitoring and remote monitoring system that efficiently controls elevator operation.
5 01 Distinctive technologies available nowhere else make the XEL suitable for VIPs. The permanent magnetic gearless traction machine First-class riding comfort The permanent magnetic gearless traction machine was developed by Hyundai Elevator. There is no vibration from the mechanism of gears. You will enjoy a comfortable, smooth riding experience as if you were riding first class. The best technology for the best building We have adopted an electric regenerative converter and high-precision control inverter drive system that optimally controls the speed of the electric motor by simultaneously and continually changing the voltage and frequency. This has resulted in the smoothest ride ever and substantially improves energy-efficiency, thus enhancing the value of a building. Advanced technology that considers even the building space Since the traction machine used for the i XEL allows for multiple arrangements, it is about 50% smaller and lighter compared to the previous induction motor. The machine occupies little space, thus allowing more space available for renting and other usage. Smart system that considers both passengers and managers More convenient services are offered based on state-of-the-art IT convergence technologies, such as the Destination Selecting System(destination floor reservation system), which reduces both wait time and unnecessary elevator operation; an artificial intelligence-based group control system that forecasts use for more efficient operation; and a computer monitoring and remote monitoring system that efficiently controls elevator operation. i. XEL I SMART TECHNOLOGY I KORAIL BUILDING IN DAEJEON, KOREA 06 07
6 USE OF NEW & RENEWABLE ENERGY 02 The XEL ensures a clean environment and unvaried performance and efficiency. GREEN TECHNOLOGY The i XEL features environment-friendly technology that minimizes carbon emissions starting from the design phase. It has used new environment-friendly and cutting-edge materials while saving construction materials. By substantially reducing the amount of carbon emitted by elevators, IMPROVED ENERGY EFFICIENCY the i XEL will further highlight the environment-friendliness of buildings. Increased recyclability Environment-friendly system A green elevator that has substantially lower electricity consumption enabled by energy reduction technologies The application of a gearless traction machine that uses a permanent magnet ensures 25% lower energy consumption compared to induction motors. Highly energyefficient lighting fixtures, such as indoor LED lighting, are used, lowering total energy consumption by around 30%. Green technology of the i XEL that reuses electricity Precise, quick motor control technologies enable precise speed control for the smoothest possible riding experience. Using regenerative Hyundai drive, it actually captures energy and feeds it back to the building s power grid. So energy efficiency can be increased by more than 77.5%. Green process where development and production take place in an environment-friendly setting By introducing a design and development process and materials that reduce environmental pollution, Hyundai Elevator is developing environment-friendly elevators that satisfy customers in every way. In line with the well-being needs of customers, we are reducing the amount of materials used throughout the development and production process, thus taking the lead in environment-friendly technology.
7 02 The XEL ensures a clean environment and unvaried performance and efficiency. IMPROVED ENERGY EFFICIENCY USE OF NEW & RENEWABLE ENERGY Increased recyclability Environment-friendly system A green elevator that has substantially lower electricity consumption enabled by energy reduction technologies The application of a gearless traction machine that uses a permanent magnet ensures 25% lower energy consumption compared to induction motors. Highly energyefficient lighting fixtures, such as indoor LED lighting, are used, lowering total energy consumption by around 30%. Green technology of the i XEL that reuses electricity Precise, quick motor control technologies enable precise speed control for the smoothest possible riding experience. Using regenerative Hyundai drive, it actually captures energy and feeds it back to the building s power grid. So energy efficiency can be increased by more than 77.5%. Green process where development and production take place in an environment-friendly setting By introducing a design and development process and materials that reduce environmental pollution, Hyundai Elevator is developing environment-friendly elevators that satisfy customers in every way. In line with the well-being needs of customers, we are reducing the amount of materials used throughout the development and production process, thus taking the lead in environment-friendly technology. i. XEL I GREEN TECHNOLOGY I LOTTE HOMESHOPPING BUILDING IN SEOUL, KOREA 08 09
8 03 The test tower, with the world s best systems, ensures the safety of the XEL. CONFIDENCE in SAFETY Comfort is based on safety. The i XEL features state-of-the-art safety systems including the self-diagnosis system, dual brake system, and door breakaway prevention system to prevent breakdowns. Furthermore, we are thoroughly researching and verifying product safety and reliability at the test tower, which is equipped with the world s very best systems. The Hyundai Asan Tower A test tower based on the world s top systems, challenging itself to showcase an ultra high-speed elevator with a speed of 18mps(1080mpm). Enhanced safety by a self-diagnosis system Further improvements were made to the overall system s reliability by adopting an ultra high-speed microprocessor that controls speed and operation. Multi-protection monitoring functions, including the self-diagnosis function, promise safety 365 days a year. Dual brake system and multi-safety circuits We adopted a dual brake system that ensures that when one brake fails, the other brake activates. The fail-safe devices and circuits make the i XEL safe. It even satisfies EN81, an European elevator standard, to ensure the world s highest safety. Safety and durability enabled by the door breakaway prevention system The door breakaway prevention system that is installed on the top and bottom of the door prevents passengers from falling outside the elevator or into the elevator shaft as a result of breakaway of the door. Safety and reliability have been certified through an impact test by a government-recognized organization. It has been applied in all Hyundai products starting in September A double deck system that boosts transport efficiency around two times based on a new dimension of flexibility Two elevators connected vertically are simultaneously run to offer 1.8 times greater transport capability. Fewer hoistways mean lower construction costs and more available floor space. An extremely strong chain operation system prevents slipperiness. Hyundai double deck system with the floor distance adjusting device provides customers a revolutionary solution to accommodate varying floor height. Unrivaled advantages of the double deck system of Hyundai Elevator Floor Distance Adjustable Device There is no restriction on floor distance. The extremely strong chain operation system prevents slipperiness and enables precise control. Aerodynamic Capsule The aerodynamic capsule minimizes air resistance. Use of lightweight materials allows a smooth riding experience with low noise and vibration. Refer to the bottom of Page 10 for a detailed explanation of the double deck system.
9 03 The test tower, with the world s best systems, ensures the safety of the XEL. The Hyundai Asan Tower A test tower based on the world s top systems, challenging itself to showcase an ultra high-speed elevator with a speed of 18mps(1080mpm). Enhanced safety by a self-diagnosis system Further improvements were made to the overall system s reliability by adopting an ultra high-speed microprocessor that controls speed and operation. Multi-protection monitoring functions, including the self-diagnosis function, promise safety 365 days a year. Dual brake system and multi-safety circuits We adopted a dual brake system that ensures that when one brake fails, the other brake activates. The fail-safe devices and circuits make the i XEL safe. It even satisfies EN81, an European elevator standard, to ensure the world s highest safety. Safety and durability enabled by the door breakaway prevention system The door breakaway prevention system that is installed on the top and bottom of the door prevents passengers from falling outside the elevator or into the elevator shaft as a result of breakaway of the door. Safety and reliability have been certified through an impact test by a government-recognized organization. It has been applied in all Hyundai products starting in September A double deck system that boosts transport efficiency around two times based on a new dimension of flexibility Two elevators connected vertically are simultaneously run to offer 1.8 times greater transport capability. Fewer hoistways mean lower construction costs and more available floor space. An extremely strong chain operation system prevents slipperiness. Hyundai double deck system with the floor distance adjusting device provides customers a revolutionary solution to accommodate varying floor height. i. XEL I CONFIDENCE in SAFETYY 10 11
10 04 The classiest space in this building is the XEL. EMOTIONAL DESIGN The design of the i XEL with cutting-edge technology, environment-friendliness, and class, does not involve designing only the limited space of the elevator. The design further upgrades the image of the entire building by adopting an outstanding spatial design that considers the building s image and functions as well as a superior sense of interior décor. High-class design Entrance design The elevator entrance is an important space that determines one s impression of a building. The extremely refined design of the i XEL embodies the sophisticated and modern image of a high-rise building. The design keeps passengers interested while waiting for the elevator and is an uncommon touch of class to the entire building. Car interior design The interior creates a pleasant feel and is of a spatial design that makes the inside look much more spacious than it actually is. It provides an enjoyable, emotional experience even during the short time passengers are inside. Detailed design of the ceiling and panel Each and every detail of the interior of the elevator ensures a distinctive sense of satisfaction, ranging from the detailed ceiling design that enables passengers to feel a sense of openness as soon as they enter the elevator to the panel design that ensures easy understanding of information and the buttons that offer a good sense of touch.
11 04 The classiest space in this building is the XEL. High-class design Entrance design The elevator entrance is an important space that determines one s impression of a building. The extremely refined design of the i XEL embodies the sophisticated and modern image of a high-rise building. The design keeps passengers interested while waiting for the elevator and is an uncommon touch of class to the entire building. Car interior design The interior creates a pleasant feel and is of a spatial design that makes the inside look much more spacious than it actually is. It provides an enjoyable, emotional experience even during the short time passengers are inside. Detailed design of the ceiling and panel Each and every detail of the interior of the elevator ensures a distinctive sense of satisfaction, ranging from the detailed ceiling design that enables passengers to feel a sense of openness as soon as they enter the elevator to the panel design that ensures easy understanding of information and the buttons that offer a good sense of touch. i. XEL I EMOTIONAL DESIGN I HYUNDAI GROUP BUILDING IN SEOUL, KOREA 12 13
12 Elevate your Thinking about Products The i XEL is more than a simple elevator. It enhances the value of a building. It is an extremely special space that moves the hearts of passengers. The greatest riding comfort that can be offered by a high-speed elevator, energy reduction effects, optimal services, and a high-class design The i XEL, will satisfy you beyond your expectations. i. XEL I PRODUCTS 14 15
13 ENTRANCE CAR DESIGN PERFORMANCE DESIGN COLLECTION 01 ENTRANCE Landing Door Bonded Metal (Delta/Bronze) Ti-Bronze 3S Vibration High Glossy Coating Jamb 200TYPE, Down Light Ti-Bronze 3S Vibration High Glossy Coating Hall Button Destination Selecting System (Box Type) Hall Lantern STS Bead Blast Half Mirror Acryl LED Lighting CAR DESIGN Ceiling Ti-Bronze Bead Blast LED Indirect Lighting Car Wall Marble (BROWNTINI) 3 Form Bear Grass (NIA) LED Lighting Car Door 3 Form Bear Grass (NIA) Ti-Bronze Bead Blast Operating Swing Panel Panel Micro Push Button Handrail Flooring Ti-Bronze Hairline 1 Pipe Marble (BOTTICINO, BROWNTINI) i. XEL I ENTRANCE & CAR DESIGN Information Display System & Lighting Destination Selecting System Hall Lantern Information Display System & Car Doors Ceiling Handrail Bottom Lighting & Flooring 16 17
14 ENTRANCE CAR DESIGN PERFORMANCE DESIGN COLLECTION 02 ENTRANCE Landing Door STS Bead Blast Jamb Flush Type, STS Bead Blast LED Lighting (Arrival Announcement System) Hall Button Destination Selecting System (Box Type) Hall Lantern HLS-750 STS Bead Blast Acryl Lens, LED Lighting CAR DESIGN Ceiling Barrisol, LED Lighting STS Mirror 3S Vibration Car Wall Marble (THASSOS) 3 Form Bear Grass (SEA WEED/19T) LED Lighting System STS Mirror 3S Vibration Car Door STS Mirror 3S Vibration Operating Swing Panel Panel Micro Push Button Handrail Flooring STS Bead Blast, LED Lighting Marble (THASSOS) STS Hairline (5T) i. XEL I ENTRANCE & CAR DESIGN Information Display System (Car Wall) Hall Lantern Arrival Announcement System Ceiling Handrail Operating Panel Button
15 ENTRANCE CAR DESIGN PERFORMANCE DESIGN COLLECTION 03 ENTRANCE Landing Door Inco-Black Mirror Etching Jamb Flush Type, Inco-Black Mirror Hall Button 70TYPE Button, Inco-Black Mirror Hall Lantern HLS-640 Inco-Black Mirror Acryl Lens, LED Lighting Indicator Deluxe Type CAR DESIGN Ceiling Inco-Black Mirror, Wood Barrisol LED Lighting Car Wall Wood, Brass Hairline Brass Hairline Trim Inco-Black Mirror Car Door Inco-Black Mirror Etching (10T) Operating Swing Panel Panel Inco-Black Mirror Etching Handwriting Operation Panel Handrail Flooring Wood1 Pipe, Ti-Bronze Hairline 1 Pipe Marble (BOTTICINO) i. XEL I ENTRANCE & CAR DESIGN Jamb Light Hall Button Indicator Handwriting Operation Panel Ceiling Handrail 20 21
16 CEILINGS & SIGNAL FIXTURES Ceiling Operating Panel STS Bead Blast, LED Lighting, Architecture Metal (DALLAS) Ti-Bronze Bead Blast, Ti-Bronze Mirror, Sheet, LED Indirect Lighting Inco-Black Mirror, Wood, Barrisol LED Lighting STS Bead Blast, LED Lighting Touch Screen Operating Panel The design may change depending on the building. OPP-N240B OPP-D241B OPP-N260A OPP-N270A OPP-N280A OPP-N290A i. XEL I CEILINGS & SIGNAL FIXTURES 22 23
17 SIGNAL FIXTURES Hall Lantern SPECIFICATIONS Group Control Operating System Installation Layout Plan & Standard Dimensions Typical Entrance Layouts Work to be done by Other Contractors Hall Button HPB-640, HPB-D841, HIP-D640, HIP-D841 : 50type, 90type button cannot be applied. Indicator Information Display System Button i. XEL I SPECIFICATIONS 24 25
18 GROUP CONTROL OPERATING SYSTEM The group control operating system is designed to optimize elevator operational efficiency by operating, distributing, and controlling such operation information as location, speed, number of passengers, and registered call numbers for each of the elevators when a hall call occurs. This improves the overall efficiency of elevator operation. Basic Functions of Group Control Standard FeatureOptional Feature Services Standard FeatureOptional Feature Feature Description Applicable Item by Building Type Artificial Intelligence Learning Function Forecast Allocation Method Artificial intelligence applying fuzzy logic automatically controls ambiguous changes in complex traffic patterns and always provides the best service. This function learns elevator usage by day and time and sets operational parameters automatically to improve group control operational performance. Optimal car usage is determined by forecasting traffic and evaluating elevator suitability for the calls. Office Hotel Multiplex Skyscraper Minimize Average Waiting Time Calls are allocated to minimize the average waiting time of passengers. Minimize Number of Long- Waiting Passengers Minimize Energy Consumption Overall Evaluation Multi-purpose Control Operation Functions When traffic demand is high, this control function minimizes the number of passengers waiting more than 60 seconds. When there is little traffic, the number of floors the elevator moves to and the number of times the elevator stops can be minimized to reduce energy consumption as much as possible. The performance of the overall system is improved by evaluating all of the previously registered hall calls as well as the newly registered calls in terms of call allocation. Optimal group control is available all the time since details such as waiting time of the basic control target, ratio of waiting passengers, and importance of energy consumption are determined automatically depending on traffic status, allowing flexible response to the traffic stream. Feature Description Applicable Item by Building Type Rush Hour Service (Up) Rush Hour Service (Down) During rush hour, elevators under group control will return to the base floor during heavy service. To minimize the waiting time of passengers going down during rush hour, the down calls are allocated to the nearest elevators. Office Hotel Multiplex Skyscraper Peak Traffic Control Considering other floor services, elevators are allocated to the floors with peak traffic. Distributed Waiting Function Idle elevators are distributed to other floors with higher demand. Allocation in Priority Elevators with calls for a certain floor are allocated to that floor as a priority. Automatic bypass A fully-loaded car will bypass hall calls in order to maintain maximum operating efficiency. Automatic Separation of an out-of-order Elevator No Service for Certain Floors Group Control including Elevators for the Handicapped Cut Service Service Reservation Indication Car Arrival Lantern An out-of-order elevator is separated from group control automatically to isolate its effect. Certain service floors are designated as closed, and elevators do not service such floors. Elevators for the handicapped are included in group control. Certain elevators are cut out from group control and transferred to independent operation by the cut service hall button. When you press the hall button, the Reserved for Service hall lantern turns on to indicate that the service is reserved. The lantern begins flashing 4 or 5 seconds prior to car arrival to alert passengers to the arriving elevator. Standard FeatureOptional Feature Feature Independent Operation Programmable Door Timer Description Cars can be separated from group control and transferred to independent operation by car calls. Applicable Item by Building Type Office Hotel Multiplex Skyscraper Timing can be set to automatic control of opening/closing of doors according to the call registered. Repeating Door Operation If the door cannot fully close, it will repeatedly open and close a specified number of times. Door Reopen by Hall If the hall button in the moving direction of the car is pressed when the Button door is closing, the door will reopen. Parking The car can be parked at a specified floor at night or on holidays. Each Floor Stop The car can be made to stop at each floor up to its arrival on a specified floor for the purpose of crime prevention during the night or on holidays. Safety Shoe If the door cannot fully close because of an object on the door track, it will repeatedly open and close until the object has been removed. Cancel Reverse Direction Call Car call registration in the reverse direction can be cancelled. Anti-Nuisance Determines the number of people in the car and compares that value to the number of car calls registered. If the number of calls exceeds the number of people in the car, the car call exceeding the number of passengers is not registered. Car Call Cancel When the registered car call button is pressed, the car call is cancelled. Light, Fan Shut-Off The light and fan in the car are automatically shut off if there is no call registered for a predetermined period of time. Auxiliary Car Operating Panel Even when the car is crowded, calls can be registered easily. Multi-Beam Door The multi-beam sensor installed in the door senses any obstruction caught in the door, Protection causing the door to reopen, or stay open before the door touches such obstruction. Photo Eye Door If the safety ray from the beam sensor in the door is interrupted, the door Protection reopens or stays open. Voice Guidance System A synthesized voice instructs passengers on current status, including floor number. Touch Button Hall or car calls can be registered only by touching. Information Display Information display installed on each floor and/or inside the car shows System traffic information and other necessary information. EDS (Electronic Inside or outside of the elevator or in the building lobby, an TFT-LCD (Thin Film Transistor- Display System) Liquid Crystal Display) or PDP (Plasma Display Panel) provides various information such as news, weather, transportation, financial news, music video, and commercials. Reserving System for The purpose of registration is to automatically select the best service sequence Target Floor of the elevator car within the system and the passenger does not need to click the car operating button in the car. It manages the elevator more effectively. LCD Touch Screen The elevator has an LCD touch screen that gives it a refined, modern style. Supervisory Operation Feature Description Standard FeatureOptional Feature Applicable Item by Building Type Office Hotel Multiplex Skyscraper Performance Monitoring The operation and performance of the elevator can be monitored in the machine room. Earthquake Service - S wave Earthquake Service - P wave Fire Emergency Service When the seismic sensor detects an earthquake, all cars stop at the nearest floors to prevent damage. When the seismic sensor detects a delicate tremor (P wave) before an earthquake (S wave) arrives, all cars stop at the nearest floors to prevent damage. When a fire breaks out, all cars are immediately called to the specified rescue floor for service. Firefighting Operation Elevators can be used by key switches for firefighting. (Emergency Elevator) Emergency Power Computer Monitoring System (HELMON) Remote Monitoring System (RMS) Service continues by automatically or manually selecting the number of cars powered by the building s emergency power source. Monitors operation of all elevators in the building and within the apartment complex. (Floors not to be serviced by the cars can be specified.) Monitors operation of elevators with RMS remotely by telephone line and computer. i. XEL I GROUP CONTROL OPERATING SYSTEM 26 27
19 INSTALLATION LAYOUT PLAN & STANDARD DIMENSIONS The hoistways of the i XEL occupy a minimum of space. They are the result of joint research and design by Hyundai Elevator s top engineers and designers. In addition to offering outstanding technologies, the hoistways have a high-class design, enabling building owners to use building space to maximum effect and passengers to enjoy a comfortable, beautiful space. Plan of Hoistway & Machine Room (In-Line Arrangement of 3 Units) / Section of Hoistway Standard Dimensions & Reactions Speed Persons/Capacity Clear Car Hoistway M/C Room M/C Room Reaction(Kg) (M/Min) Opening Internal External 1Car 2Cars 3Cars Depth 1Car 2Cars 3Cars Depth persons (kg) OP CA x CB A x B x 1 x 2 x 3 Y MX1 MX2 MX3 MY R1 R Temperature should be maintained below 40 C and humidity below 90%, with installation of a ventilating fan, ventilating grille, and air conditioner (if necessary). Toxic gas or dust should not be generated Face-to-Face Arrangement The minimum hoistway dimensions are shown in the above table. Some allowances should be made in consideration of the sloping of the hoistways. 2. The above dimensions assume use of cars with center opening doors. Consult Hyundai for dimensions with side opening doors. 3. For elevators with capacity of more than 28 persons, consult Hyundai. 4. When non-standard capacities and dimensions are required to meet the local code, consult Hyundai. 5. The capacity in persons is calculated at 65kg/person. (EN81=75kg/person) 6. The above dimensions are applied in case the door is standard. In case a fire protection door is required, the hoistway size for one car should be applied above X1 dimension plus 100mm. 7. The maximum speed capabilities of Hyundai is 1080m/min. Consult Hyundai Speed M/Min i. XEL I INSTALLATION LAYOUT PLAN & STANDARD DIMENSIONS 1. The above table shows minimum figures. Therefore, some allowances should be made considering errors that may occur during construction. 2. Above dimensions are applied in case car height is 2800 mm. In case car height is over 2800 mm, overhead should be applied above dimension plus additional height
20 TYPICAL ENTRANCE LAYOUTS WORK TO BE DONE BY OTHER CONTRACTORS (CONDITIONS FOR ESTIMATE) The following works are not included in the elevator contract, and shall be done by other contractors in accordance with Hyundai Elevator s drawings and the applicable codes and regulations. The reference rules shown are from Code ANSI. Building Work Electrical Work Entrance Structural Opening of Entrance In case of Boxless type Button and Fire man's Switch Entrance Structural Opening of Entrance In case of Boxless type Button and Fire man's Switch Entrance Structural Opening of Entrance In case of Boxless type Button and Fire man's Switch Hoistway 1. Clear, plumb hoistway with fire resistant hatch walls as required by the applicable code. (Rule 100.1a) bevel guards on all projections, recesses, or setbacks over 50mm except on side used for loading or unloading. (Rule 100.6) 3. Venting of the hoistway as required by the applicable code or responsible authority. (Rule 100.4) 4. Supports for rail brackets at each floor, roof, and machine room. (Rule 200.9) Maximum allowable vertical spacing of rail supports without backing. (Rule and 301.1) Divider beams 100mm between hoistway at each floor and roof, for guide rail bracket supports. (Rule 200.4, and 301.1) 5. Recesses supports and patching as required to accommodate hall button boxes, signal fixtures, etc. 6. All barricades either outside elevator hoistways or between inside hoistways as required. 7. Dry pit reinforced to sustain normal vertical forces from rails and buffers. (Rule 106.1b and 109) Consult Hyundai Elevator Company for rail forces and buffer impacts. Where there is space below the pit floor that can be occupied, consult Hyundai Elevator Company for special requirements. (Rule 300.4) Cylinder hole, casings under the pit as required, and backfilling around the cylinder casings when direct plunger type is to be installed. 8. Where access to the pit is by means of the lowest hoistway entrance, vertical iron ladder extending 1060mm minimum above sill of access door. (Rule 106.1d) 9. Entrance walls and finished floor are not to be constructed until after door frames and sills are in place. Door frames are to be anchored to walls and properly grouted in place to maintain legal fire rating. 10. For application as indoor or outdoor observation elevator, a glass enclosure of at least 3.6m in height at the bottom landing is recommended for safety. For use as an outdoor observation elevator, a full-height glass enclosure is required. Machine Room 11. Enclosed and protected machine room. (Rule 101.1) 12. Access to the machine room and machinery space as required by the applicable code or responsible authority. (Rule 101.3) 13. Reinforced concrete machine room floor slab or grating, as specified, which must not be placed over the hoistway until elevator machinery is set in position. (Rule for Traction Elevator) Clear access above ceiling or trench in floor, for oil line and wiring duct from machine room, if machine room is remote from elevator hoistway. (For Hydraulic Elevator) Cutout through machine room wall, for oil line and wiring duct as required by Hyundai Elevator s shop drawings. (For Hydraulic Elevator) 14. Hoisting beams, trap doors, and other means of access to machine room for maintenance and equipment removal purposes. (Rule 101.3d) 15. Cable guards in the machine room or secondary level. (Rule 104.1) 16. Supports for machine and sheave beams and reactions including wall pockets and patching after beams are set in place. (Rule to 105.5) Electric Power Requirements (By others) 13 (900) 15 (1000) 17 (1150) The above power sizes are for lengths of electric wire up to 50 meters from the elevator machine room to the transformer. For lengths of 50 meters or more, the following formula should be applied : Power feeder length(m) Power feeder size (mm 2 )= X size in the above (mm 2 ) Hoistway 1. Light outlet for each elevator, in center of hoistway (or in machine room) as indicated by Hyundai Elevator Company. 2. Convenience outlet and light fixture in pit with switch located adjacent to the access door. (Rule 106.1e) 3. Wiring and piping work of emergency bell, interphone, etc. outside the hoistway and the machine room. Machine Room 4. Lighting, convenience outlets, ventilation, heating of machine room, and machinery space. (Rule 101.5) 5. Temperature should be maintained below 40 C by a ventilating fan and/or air conditioner, if necessary, and humidity below 90%. 6. A fused disconnect switch or circuit breaker for each elevator and light switch located per the applicable code and where practicable located adjacent to the door of the machine room. (Rule and 306.7) 7. Feeder and branch wiring to the controller, including main-line switch and convenience outlets. 8. Suitable power feeder and branch wiring circuits as required for elevators with power-operated doors, including disconnect switch or circuit breaker. Emergency Provisions 9. Elevator fireman s and other emergency services wiring and interconnections to automatic sprinkler systems or heat and smoke sensing devices furnished by others and installed to terminal points on the elevator controllers. 10. When emergency power operation of elevators is required, the electrical contractor should coordinate with Hyundai Elevator Company or local distributor for operation requirements. 11. Elevator fireman s and other emergency service requirements may differ from each country. Consult Hyundai Elevator Company or local distributor for other local requirements. 12. When provisions for earthquake protection are required, consult Hyundai Elevator Company for special requirements. HEAT EMISSION OF MACHINE ROOM Q(kcal/H)=W x V x F x N W: Capacity (kg) V : Speed F : Factor N : Number of cars F :1/40-VVVF 20 (1350) 24 (1600) Above power feeder sizes are for copper wires inside electro-metallic tubing. 3. It is recommended a larger diameter earth wire be used. 4. For installing several elevators, apply the following formula. Transformer Capacity (kva) = Number of elevator X Diversity factor 5. For AC-Geared elevators, consult Hyundai Elevator. 6. Consult Hyundai if you need eletric power requirements for 220V. i. XEL I TYPICAL ENTRANCE LAYOUTS / WORK TO BE DONE BY OTHER CONTRACTORS 30 31
21 Prize & Certification Hyundai Elevator Network HEAD OFFICE & FACTORY SEOUL OFFICE (INT L SALES DIV.) San 136-1, Ami- ri, Bubal- eup, Icheon-si, Gyeonggi-do , Korea tel 82_2_3670_0665/0668 fax 82_2_3672_8763~4 [email protected] 8F East Bldg, Hyundai Group Bldg., 1-7 Yeonji-dong, Jongno-gu, Seoul , Korea tel 82_2_3670_0665/0668 fax 82_2_3672_8763~4 INTERNATIONAL SALES & SERVICE NETWORK ALGERIA Sarl Howsol Pan Ingenierie et Commerce Lido, Cite Baha 3, No 28 Mohammadia, Alger, Algeria Tel : /87 Fax : BAHRAIN Nass International Trading Co.W.L.L P.O. Box 669, Ma'ameer Sitra, Kingdom Of Bahrain Tel : Fax : BANGLADESH Regional Traders Ltd. Karim Chamber(3rd Floor)99, Motijheel Commercial Area Dhaka-1000, Bangladesh Tel : Fax : CHINA Shanghai Hyundai Elevator Manufacturing Co., Ltd. Head Office(Factory) No.182, Zhenxi Nanlu Liantang Zhen, Qingpu-Qu, Shanghai China Tel : /3990/3961/3971 Fax : Shanghai Office Room 506, Yuan Zhong Scientific Research Bldg., No.1905 Hongmei-Lu, Xuhui-Qu, Shanghai, , China Tel : Fax : /3512 EGYPT International Eng. & Trade 10 El Hakam St., Helmeyt El Zayton Cairo, Egypt Tel : Fax : INDIA Kinetic Hyundai Elevator & Movement Technologies Ltd. G-92, D- Block, Midc, Chinchwad, Pune India Tel : /2191 Fax : INDONESIA PT. Superhelindo Jaya JL. KH. Moch. Mansyur No 19B, Jakarta 10140, Indonesia Tel : Fax : IRAN Mehfakhr. Flat No. 84 8th Flr. No. 23 Corner of 13th St. Asadabadi Ave. Tehran Iran Tel : Fax : IRAQ Bemco Al-Arjoon Company For General Construction Ltd. Baghdad Karrada Salman Faiq Street Tar Al-Rasheed Building 3-D Floor Tel : Fax : JORDAN Bseiso Engineering Materials Corp. P. O. Box Amman 11183, Jordan Tel : Fax : KUWAIT Deal General Trading & Contracting Co. P. O. Box Safat, Kuwait Tel : Fax : MONGOLIA Tdels Co., Ltd. Sukhbaatar District 2 Khoroo Ubmart Center, Room #518 Ulan Bator, Mongolia Tel : Fax : OMAN North Ocean Enterprises L.L.C. P.O.Box 3725, P.C.112, Ruwi, Sultanate Of Oman Tel : Fax : PAKISTAN Islamabad Industrial & Trading Corp. 205 Amber Estate Shahra-e-faisal, Karachi , Pakistan Tel : ~5 Fax : PANAMA Elevadores De Panama S.A. Via Ricardo J. Alfaro, Diagonal Hospital S.M. Arcangel Republic of Panama Tel : Fax : PHILIPPINES Hyco Industrial Sales Corp. #81 Kapiligan Cor. Bayani St., Brgy. Dona lmelda, Quezon City, Philippines Tel : /0923 Fax : QATAR International Eng. & Trade Group Co. P. O. Box N Doha, Qatar Tel : Fax : SAUDI ARABIA ETA-Electromechanical & Technical Associates, Al Murjan Tower, 11th Floor, Suite #1104, Hail Street and Waly Al Ahd Street Intersection, P. O. Box 6591, Jeddah-21452, Saudi Arabia Tel : Fax : THAILAND Loxley Public Co., Ltd. Construction Materials Department, 102 Na Ranong Rd, Klongtoey, Bangkok 10110, Thailand Tel : Fax : /3128 TUNISIA Ascenseurs Levage & Manutention(ALM) Rue Abderrahmen Ibn Aouf Cite Uv4 Bloc Menzeh 6 tunis - Tunisie Tel : Fax : TURKEY HMF Makine ve Servis San. ve Tic.A.S. Esentephe Mah. E5 Yanyol No.15 Kartal - Istanbul Tel : Fax : U.A.E. Midein Electromechanical L.L.C. P.O. Box Villa No.3 Al Karama 24th Street, Abu Dhabi, U.A.E. Tel: Fax: Bin ham North Ocean Elevators L.L.C. P.O. Box Dubai, U.A.E. Tel : Fax U.S.A Park Bros, INC 167 S Fuller AVE L.A C.A U.S.A. Tel : [email protected] VENEZUELA Cozy Life Elemecanico, C.A AV. Francisco De Miranda, Edif.Vesubio, Piso Pb, Local 01, URB. La California Norte, Caracas, Venezuela Tel : Fax : Elevate your thinking with hyundai elevator i XEL, a high-class, high-speed elevator that is suitable for a cutting-edge building. Distinctive, highly-reliable technologies ensure top satisfaction for architect builders, owners, as well as users. Now is the time to enjoy the benefits offered by Hyundai Elevator s i XEL. We reserve the right to change designs and specifications for the product development without prior notice. Copyright HYUNDAI ELEVATOR CO., LTD. All rights reserved. Printed in Korea. C-HEI-E0107 / / First edition
Hospital Bed ElevatorS
San 136-1, Ami- ri, Bubal-eup, Icheon-si, Gyeonggi-do 467-734, Korea Tel : 82-2-3670-0653/0665 Fax : 82-2-3672-8763~4 www.hyundaielevator.co.kr SEOUL OFFICE(INT L SALES DIV.) 8F East Bldg, Hyundai Group
U.S.A. Park Bros, INC 167 S Fuller AVE L.A C.A 90036 U.S.A. Tel : 213-248 - 2239 E-mail : [email protected]
Moving solutions with safety, reliability and efficiency HEAD OFFICE & FACTORY San 136-1, Ami- ri, Bubal- eup, Icheon-si, Gyeonggi-do 467-734, Korea Tel : 82-2-3670-0669/0988 Fax : 82-2-3672-8763~4 Homepage
Hyundai Elevator THE EL. Ultra High speed ELevator
Hyundai Elevator THE EL Ultra High speed ELevator Intro Philosophy 8 Prestige technology Elevate to The Exclusive Leader Hyundai Elevator The sole elevator is for a building of unrivaled height. Smart
HYUNDAI ELEVATOR THE EL ULTRA HIGH SPEED ELEVATOR
HYUNDAI ELEVATOR THE EL ULTRA HIGH SPEED ELEVATOR 03 Intro 05 Philosophy 08 Prestige technology Elevate to The Exclusive Leader Hyundai Elevator 10 12 14 The sole elevator is for a building of unrivaled
Refined design Refined design to give consideration to health and the environment adds new value to the elevator.
HEAD OFFICE & FACTORY San 136-1, Ami- ri, Bubal-eup, Icheon-si, Gyeonggi-do 467-734, Korea Tel : 82-2-3670-0661/0665 Fax : 82-2-3672-8763~4 www.hyundaielevator.co.kr SEOUL OFFICE(INT L SALES DIV.) 8F East
S WORK CATALOGUE FAA29100H_BWC
MACHINE ABOVE - 2, m/s BUILDER S WORK CATALOGUE FAA29100H_BWC 07-04-15 Version: a-e 800 kg 0 kg Otis Elevator Company 2007, All rights reserved MAIN 2/38 This catalogue summarizes useful information for
Planning Information. Passenger and Freight Elevators.
A company of ThyssenKrupp Elevator Thyssen Aufzüge tk This planning information will give you an overview of the most important planning criteria of passenger and freight elevators. However you should
Lift and Escalator Installations
Buildings Department Practice Note for Authorized Persons, Registered Structural Engineers and Registered Geotechnical Engineers APP-29 Lift and Escalator Installations Building Works Requirements The
CITY AND COUNTY OF DENVER POLICY DENVER FIRE DEPARTMENT SUBMITTAL OF CONVEYANCE INSTALLATION/ALTERATION PLANS
Subject: SUBMITTAL OF CONVEYANCE INSTALLATION/ALTERATION PLANS Reference: Denver Fire Code Section 105.7.29 Approved: Joseph L. Gonzales, Division Chief, Fire Prevention Division Number: 105-1 Effective
ITEM DESCRIPTION SPECIFICATION TENDER OFFER
TECHNICAL SPECIFICATIONS PL1 & PL2 PLEASE TICK IF YOU COMPLY. SPECIFY YOUR OPTION IF YOU DON'T. ITEM DESCRIPTION SPECIFICATION TENDER OFFER Make (please specify) 1.0 Type Duplex Passenger Lift 2.0 Minimum
Switch. Building technology for the real world.
Switch Building technology for the real world. S A F E S I M P L E S U S T A I N A B L E Technology that s designed to work for you. Special power requirements. Subcontractor s schedules. Frequent power
Skyrise. Engineered to meet the highest of challenges. The Skyrise system delivers:
SkyriseTM Skyrise Engineered to meet the highest of challenges In the last 100 years, 10 buildings earned the distinction of being the world s tallest. Eight of them relied upon Otis for their elevator
MTA UNIVERSAL STATION PEDESTRIAN BRIDGE Los Angeles, CA. Project Manual and Specification 100% PE SUBMITTAL TABLE OF CONTENTS
Los Angeles, CA Project Manual and Specification DIVISION 1 GENERAL CONDITIONS 01 01 10 STATEMENT OF WORK 01 11 00 SUMMARY OF THE WORK 01 14 05 METRO (OWNER) - DIRECTED STOPPAGES 01 20 00 PRICE AND PAYMENT
The KONE Motala 2000 platform lift suits the architecture of any building, thanks to the wide range of car and shaft design options.
A solution for making all premises accessible KONE Motala 2000 The KONE Motala 2000 platform lift suits the architecture of any building, thanks to the wide range of car and shaft design options. This
Auto Parking Systems. For an ideal solution to today s city parking problems, Hyundai provides the advanced Auto Parking System.
Auto Parking Systems For an ideal solution to today s city parking problems, yundai provides the advanced Auto Parking System. At yundai Elevator Co., Ltd., we create the most efficient parking systems
INSTALLATION GUIDELINES for SOLAR PHOTOVOLTAIC SYSTEMS 1
City of Cotati Building Division 201 W. Sierra Ave. Cotati, CA 94931 707 665-3637 Fax 792-4604 INSTALLATION GUIDELINES for SOLAR PHOTOVOLTAIC SYSTEMS 1 Any PV system on a new structures should be included
Roped Hydraulic Residential Elevator Specifications
January 1, 2004 Roped Hydraulic Residential Elevator Specifications P.O. Box 749, 5191 Stump Rd., Plumsteadville, PA 18949 Toll Free: 888-443-2800, Phone: 215-766-3380, Fax: 215-766-3385 CONTENTS Part
Interfacing Elevators with Fire Alarm and Sprinklers
Interfacing Elevators with Fire Alarm and Sprinklers IEEE Atlanta Chapter May 15, 2006 Brian K Fabel, PE Agenda Today s Codes NFPA, ASME, IBC/IFC Conflicts/Issues Tomorrow s Codes? Applicable Codes NFPA
SECTION 10680 MediaStation Model 125 Electric Lateral Files (ELF)
SECTION 10680 MediaStation Model 125 Electric Lateral Files (ELF) PART 1-GENERAL 1.01 RELATED WORK SPECIFIED IN OTHER SECTIONS A. Electrical connections see electrical specifications. 1.02 SUBMITTALS A.
Machine Room Less (MRL) Elevators. Evolution in elevator design.
Machine Room Less (MRL) Elevators. Evolution in elevator design. By: Bill Glas, Product Manager, Schindler Elevator Corporation Machine Room Less (MRL) elevators are an emerging yet proven technology and
VDI 4707 Energy Efficiency Label for Elevators
VDI 4707 Energy Efficiency Label for Elevators Schindler s Approach to Sustainability Life Cycle Assessment (LCA) With elevators and escalators accounting for up to 15% (*Source : CIBSE Guide D) of the
FOR IMMEDIATE RELEASE
FOR IMMEDIATE RELEASE Hitachi to Deliver the World s Fastest *1 Ultra-High-Speed Elevators With a Speed of 1,200 m/min for a Mixed-Use Skyscraper in Guangzhou, China in 2016 Tokyo, Japan and Guangzhou,
LIFT CONTROL SYSTEMS CATALOGUE 2007
LIFT CONTROL SYSTEMS CATALOGUE 2007 All Your Needs For Elevators INDEX 1. Lift Control Cards... 3 2. Speed Control Units... 7 3. Emergency Rescue Cards... 8 4. Lift Control Panels... 10 5. Photocells...
freight elevators 2008 planning guide ThyssenKrupp Elevator Americas Business Unit
freight elevators 2008 planning guide ThyssenKrupp Elevator mericas usiness Unit TK Our ommitment To You ependable. Tough. Efficient. The qualities you need in your freight elevators are the qualities
LOADING DOCK EQUIPMENT. A. Section 03100 - Concrete Forms and Accessories: Placement of anchors into concrete.
LOADING DOCK EQUIPMENT PART 1 GENERAL 1.1 SECTION INCLUDES A. Loading dock equipment of the following types: 1. Dock lifts. 2. Control stations. 1.2 RELATED SECTIONS A. Section 03100 - Concrete Forms and
Schindler 3300 AP A remarkable style that suits the building. The machine room-less passenger elevator that unifies form and function.
A remarkable style that suits the building. The machine room-less passenger elevator that unifies form and function. Schindler Passenger Elevators Key figures Capacity Travel height One- or two-sided entrance*
LIFT CONTROL SYSTEMS CATALOGUE 2007
LIFT CONTROL SYSTEMS CATALOGUE 2007 All Your Needs For Elevators INDEX 1. Lift Control Cards... 3 2. Speed Control Units... 7 3. Emergency Rescue Cards... 8 4. Lift Control Panels... 10 5. Photocells...
SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS
SECTION 08360 SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS Display hidden notes to specifier by using Tools / Options / View / Hidden Text. On newer versions of Microsoft Word
BUILDING PERMIT SPECIFICATIONS
BUILDING PERMIT SPECIFICATIONS The below noted requirements are based upon La Plata County Building Code. These specifications are not intended as a complete set of requirements, but are intended to provide
It starts with a commitment to environmentally friendly solutions: Innovative products and services that reduce cost and energy usage.
It starts with a commitment to environmentally friendly solutions: Innovative products and services that reduce cost and energy usage. Let Otis show you The Way To Green. The Way To Green is about our
The Impact of the new Directive 2014/33/EU and Standard EN81-20 on New Lifts
The Impact of the new Directive 2014/33/EU and Standard EN81-20 on New Lifts Malta Lift Association Workshop Ing Ray Spiteri DMS, MBA (Brunel), B.Sc.. Mech Eng (Hons), EUR Ing, MIMechE, MASHRAE, MIAEE,
Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone: 0041 22 77 66 051 [email protected]
CARDOK CARLIFT Fast access to underground garages Fast, Silent, Discreet, Design, High-Tech Installation to replace an access ramp on private property Dimensions: (Built to measure, all dimensions can
Fire. The Fire Installers Mate. A guide to fire alarm systems design
Fire The Fire Installers Mate A guide to fire alarm systems design BS 5839 Part 1:2002 A guide to BS 5839 Part 1:2002 Disclaimer This booklet is not intended to be a comprehensive guide to all aspects
Greening your Buildings with Schindler Modernisation
Greening your Buildings with Investing in a sustainable future The importance of greening buildings Buildings account for one third of the world s total energy consumption and a similar percentage of the
CONSOLIDATED EDISON CO. OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY 10003 DISTRIBUTION ENGINEERING DEPARTMENT SUBSTATION & EQUIPMENT SECTION
CONSOLIDATED EDISON CO. OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY 10003 DISTRIBUTION ENGINEERING DEPARTMENT SUBSTATION & EQUIPMENT SECTION SPECIFICATION EO-5023 REVISION 3 MARCH 2003 REQUIREMENTS FOR
DEPARTMENT OF CORRECTIONS
Elevator Consulting, LLC. Post Office Box 464 Mequon, WI 53092-0464 Voice/Fax: 262-242-3077 Mobile No: 262-853-1054 E-mail: [email protected] DEPARTMENT OF CORRECTIONS MILWAUKEE SECURE DETENTION
Current as of 11/10/08 1 of 1
BEST PRACTICES STANDARDS FOR SCHOOLS UNDER CONSTRUCTION OR BEING PLANNED FOR CONSTRUCTION I. Site Layout A. School buildings shall be provided with a securable perimeter. A securable perimeter means that
Home Inspection Report
4949 Brownsboro Rd Suite 293 Louisville, KY 40223 (502) 414-1440 [email protected] Inspected By: William Carter, HI-1956 Home Inspection Report Prepared For: Edward Cullen Property Address:
Assessment of Elevator and Escalator Maintenance & Repair Program Final Elevator Audit Submission Bethesda Station - Escalator A09X04 (Station)
Bethesda Station - Escalator A09X04 (Station) Ride Quality Test Results The Parametricoder is a time and displacement encoding system that measures mechanical performance characteristics on escalators.
V1504 Vertical Platform Lift OWNER S MANUAL
V1504 Vertical Platform Lift OWNER S MANUAL (To Be Retained by Owner After Installation by Authorized Savaria Dealer) Part No. 000692 03-m12-2013 2 IMPORTANT Ensure that only an authorized Savaria Dealer
Schindler 5500 Efficiency. Flexibility. Performance.
Efficiency. Flexibility. Performance. Schindler Passenger Elevators Key figures Capacity 2100 lb (950 kg) to 5000 lb (2270) kg Travel height Up to 350 ft (107 m) Door width Up to 4 6 Door height Up to
V1504 Vertical Platform Lift OWNER S MANUAL
V1504 Vertical Platform Lift OWNER S MANUAL (To Be Retained by Owner After Installation by Authorized Savaria Dealer) Part No. 000692 01-m03-2016 2 IMPORTANT Ensure that only an authorized Savaria Dealer
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
SECTION 14 20 10 - FREIGHT & PARKING GARAGE ELEVATORS PART I - GENERAL
SECTION 14 20 10 - FREIGHT & PARKING GARAGE PART I - GENERAL 1.1 SECTION INCLUDES [NOTE to AE: The following lists requirements that are specific to freight elevators. These requirements are in addition
DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS
DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS NOTICE TO BIDDERS BID FORM INSTRUCTIONS TO BIDDERS CONTRACTOR S BID FOR PUBLIC WORK - FORM 96 MINORITY AND WOMEN S BUSINESS ENTERPRISE PARTICIPATION
Building Condition Assessment Report
C2 - Nurses Resident (aka Administration) Building Condition Assessment Report Asset Address Address Construction Year Size (Gross Floor Area) Asset Type Floors Above Ground Inspection Date C2 - Nurses
MACHINE ROOM-LESS PERFORMANCE IN A HYDRAULIC ELEVATOR HOISTWAY. KONE EcoSpace
MACHINE ROOM-LESS PERFORMANCE IN A HYDRAULIC ELEVATOR HOISTWAY KONE EcoSpace The revolutionary machine room-less elevator concept KONE s machine room-less (MRL) technology eliminates the need for a machine
SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT
SECTION 23 00 01 HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION A. The Work specified in this Section consists of designing, furnishing and installing factory-assembled
Nominal Life Expectancy for Building Components
Nominal Life Expectancy for Building Components Building System Page A. HVAC 2 B. Elevator/Escalator 6 C. Plumbing 7 D. Roofing 8 E. Electrical 10 F. Fire/Life/Safety/Security System 11 G. Interior Finishes
BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS
BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS BURGLAR ALARM SYSTEM EURO ALARM Six zones with the following connection capabilities: One
P.A.L. S SPECIFICATIONS
PART 1- GENERAL 1.1 SCOPE To furnish all labor, materials and equipment necessary or required to complete the installation of the lift as indicated on the Drawings and Specifications. This specification
Guideline for Fire Safety Elements of Solar Photovoltaic Systems July 17, 2008 Rev: 1/1/10
Guideline for Fire Safety Elements of Solar Photovoltaic Systems July 17, 2008 Rev: 1/1/10 This document was developed by the Orange County Fire Chiefs Association, Orange County Fire Marshal Committee.
MISCELLANEOUS ELECTRICAL JOBS REQUIRING PERMITS
MISCELLANEOUS ELECTRICAL JOBS REQUIRING PERMITS 01. SAFETY INSPECTION of service equipment at FPL Power Source 02. Construction GFI power outlets (Temp Pole for Construction) 03. 90 day temporary power
CLIENT. Inspection Report. 271 Front St. Alert Bay, B.C. Island Building Inspections V ANCOUVER I SLAND B. C.
CLIENT Inspection Report 271 Front St. Alert Bay, B.C. Island Building Inspections 2013 V ANCOUVER I SLAND B. C. Elevation Photos For the Property at 271 Front Street Alert Bay, BC ELEVATION PICTURES Front
Saint Cloud Business Center
Saint Cloud Business Center 14 7th Avenue North Saint Cloud, MN 56303 For Sale Located on 7th Avenue in the heart of downtown across from the Court House Square. A large professional reception area with
Solar Panel Installations
Solar Panel Installations Page 1 of 6 SINGLE-FAMILY RESIDENTIAL CHECKLIST City of Hayward Development Services Department Revised: 7-09-15 PERMIT REQUIREMENTS Permits are required for all solar panel installations.
How SafePlug Smart Receptacles Can Save Money in Commercial Buildings
How SafePlug Smart Receptacles Can Save Money in Commercial Buildings by Steve Montgomery, P.E. 2D2C, Inc. SafePlug smart receptacle system add the ability to accurately identify exactly what appliance
Sub-Bid Contractor Update Statement. Tab A - Invitation for Bids. Tab B - Instructions to Bidders
INTRODUCTORY INFORMATION TABLE OF CONTENTS 00 0101 PROJECT TITLE PAGE PROCUREMENT REQUIREMENTS (PROJECT MANUAL) Tab A - Invitation for Bids Tab B - Instructions to Bidders Tab C Bid Form for General Bids
SWIMMING POOL HEAT PUMP
SWIMMING POOL HEAT PUMP Installation & User Manual Model HP40B HP50B HP65B Hayward Pool Products Canada, Inc. T: 1-888-238-7665 www.haywardpool.ca CONTENT I. Application 4 II. Features 4 III. Technical
KONE elevators for commercial buildings
KONE elevators for commercial buildings Your trusted elevator partner for residential buildings With over 100 years of experience in the elevator and escalator business, KONE is your trusted partner dedicated
TANKLESS WATER HEATER INSTALLATION DIAGRAMS
TANKLESS WATER HEATER INSTALLATION DIAGRAMS Installation Diagrams Tankless Installation / Optional Return Small 10-15 Gallon Point-of-Use Water Single and Optional Return : One single, small capacity water
Submit shop drawings for equipment provided under this section Shop drawings shall indicate:
Section 16435 - SWITCHBOARDS Introduction Part 1 - General Reference The work under this section is subject to requirements of the Contract Documents including the General Conditions, Supplementary Conditions,
Name Of Occupancy Date. Yes No Describe
FIRE PREVENTION INSPECTION CHECKLIST For Class A Occupancy (For Assembly Buildings, Bars, Restaurants, Gyms, Churches, Arenas, Theatres or wherever people gather) Name Of Occupancy Date Physical Address
COLOR VIDEO DOOR PHONE CDV-71BE/D
COLOR VIDEO DOOR PHONE CDV-71BE/D 513-11, Sangdaewon-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do, Korea Int l Business Dept. : Tel.; +82-31-7393-540~550 Fax.; +82-31-745-2133 Web site : www.commax.com Printed
CLEAR-DIVISIONS CENTERFOLD
CLEAR-DIVISIONS CENTERFOLD Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS CENTERFOLD moveable The yellow highlighted areas in
Electrical. This section applies to the design and installation of building power distribution systems.
Basis of Design This section applies to the design and installation of building power distribution systems. Design Criteria This section contains the architectural, structural and mechanical provisions
Cooktop Low-Profile Ventilation Hoods
INSTALLATION GUIDE Cooktop Low-Profile Ventilation Hoods Contents Wolf Cooktop Low-Profile Ventilation Hoods........ 3 Cooktop Low-Profile Hood Specifications.......... 4 Cooktop Low-Profile Hood Installation............
Building Control Guidance Note
Issued 01/01/13 Rev Page 1 of 5 If you intend to convert an existing loft space into additional rooms you will need to apply for Building Regulation Approval. You may also need Planning Permission if you
UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS
UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS: Carefully read these instructions before installing your new air-conditioner. AUSTRALIAN AUTOMOTIVE AIR AL00500054E 1 Table
PUBLIC VERTICAL PLATFORM LIFT PLANNING GUIDE
Multilift PUBLIC VERTICAL PLATFORM LIFT PLANNING GUIDE Applicable Codes: ASME A17.1 ASME A18.1 CSA B613 CSA B355-09 19-m01-2015 Part No. 000790 Copyright 2015 Savaria Corporation All rights reserved. Printed
www.citiesinspection.com October 5, 2015 Dear Client,
www.citiesinspection.com October 5, 2015 Dear Client, On 9/14/2015, Cities Inspection Service, Inc. completed a building inspection of the property located at 123 Oak Street, Someplace, Minnesota for you.
york air-conditioning products Residential & VRF News 2015
york air-conditioning products Residential & VRF News 2015 york air-conditioning products Catalogue Content Split Systems Pag. High wall High Efficiency Inverter YWHJZH 09 to 24 K 6 High wall Inverter
TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST
TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST In order to provide a comprehensive plan review in a timely manner, and to insure the design and installation of fire alarm systems
EKON BMS HVAC system. Simply Smart. www.ekonhome.com. Touch Screen Controller. Going green. Wireless. Wireless Thermostat with Light Switch
Going green EKON BMS HVAC system Wireless Thermostat with Light Switch Control Fan Coil or Central AirCon Wireless Touch Screen Controller Wireless Light or Motorized Blind Wall Switch www.ekonhome.com
products 22 º C Ventilation Air Conditioning Refrigeration Energy & Cost Saving Products Inside PROVIDED BY HEINEN & HOPMAN
products > Energy & Cost Saving Products OUTSIDE 35 C HUMIDITY 90% 22 º C Inside PROVIDED BY HEINEN & HOPMAN Heating Ventilation Air Conditioning Refrigeration HVAC energy & COST SAVING POSSIBILITIES A
Vision Home Inspection
Vision Home Inspection 324 Rams Run Shepherdsville KY 40165-7877 Inspector: James McFadden Property Inspection Report Client(s): Property address: Inspection date: View report summary This report is the
IH 17025 E Sigma Island 90
INSTRUCTIONS FOR USE Kitchen extractor hood Type: IH 17025 E Sigma Island 90 Dear Customer!! You are now a user of the newest generation kitchen extractor hood type IH 17025 E Sigma Island 90. This hood
Element D Services Plumbing
Medical Vacuum and Gas PART 1 - GENERAL 1.01 OVERVIEW A. This section addresses medical vacuum, waste anesthetic gas disposal, compressed air, oxygen, nitrous oxide, nitrogen and carbon dioxide systems.
CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services
CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services 575 E. Flamingo Road, Las Vegas, NV 89119 (702) 455-7316 FAX (702) 455-7347 105.8a-6.1 TITLE: FIRE ALARM SYSTEM REQUIREMENTS SCOPE: This guideline
Stereoscopic 3D Digital Theater System. Operator Manual (MI-2100)
Stereoscopic 3D Digital Theater System Operator Manual (MI-2100) -1- All information contained in or disclosed by this document is confidential and propriety to masterimage Co., Ltd. (hereinafter referred
CLEAR-DIVISIONS APERTO
CLEAR-DIVISIONS Introduction: The following three (3) part specification offers the Standard and Optional features for the CLEAR-DIVISIONS moveable glass wall system. The yellow highlighted areas in the
User Manual. Video Doorphone CDV-1020AQ
User Manual Video Doorphone CDV-1020AQ 513-11, Sangdaewon-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do, Korea Int l Business Dept. Tel. : +82-31-7393-540~550 Fax. : +82-31-745-2133 Web site : www.commax.com
ABB Stotz-Kontakt GmbH ABB safe&smart Project planning of security systems
ABB Stotz-Kontakt GmbH ABB safe&smart Project planning of security systems Content Introduction Preventing unauthorized access by perimeter surveillance Monitoring unauthorized access by indoor surveillance
EFA PSBP. Natural Ventilation Strategy. Introduction. 1.1 Relevant legislation. 1.1.1 The Building Regulations 2010
EFA PSBP Natural Ventilation Strategy Introduction The Baseline Designs Project will provide scheme design details for a number of Primary and Secondary School Exemplars. For the purposes of setting a
Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner
Elegant ECM Ceiling Air Conditioner ELEGANT ECM air conditioners allow to heat and cool very economically small and medium areas, like shops, show rooms, workshops, supermarkets. The range is made up of
LET OUR HYDRAULIC LIFTS HANDLE THE PRESSURE
LET OUR HYDRAULIC LIFTS HANDLE THE PRESSURE Introduction to the Elite Group of Companies, represented by VWS Lifts Elite Elevators Limited was formed in 1988 and in 1999 we divided into three operating
2. What building projects are exempted? (permit not required)
BUILDING AND SAFETY DEPARTMENT 1. What building projects require a permit? Following is a list of projects that require building permits based on Appendix chapter 1 of the California Building Code and
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
Hydraulic Controllers, PHC, HS
General In This Section PHC HS Hydraulic Controllers, PHC, HS General Model HMC-1000 controllers, industry recognized for over a decade, provide field proven reliability for all hydraulic elevator applications.
FIRE ALARM SYSTEMS PERMIT APPLICATION, PLAN SUBMITTAL, DESIGN, INSTALLATION AND INSPECTION REQUIREMENTS Effective Date: January, 2011
Office of the Fire Marshal 1.0 PERMITS FIRE ALARM SYSTEMS PERMIT APPLICATION, PLAN SUBMITTAL, DESIGN, INSTALLATION AND INSPECTION REQUIREMENTS Effective Date: January, 2011 1.1 To acquire an installation
KONE solutions for airports
A PLEASANT FLIGHT BEGINS AND ENDS AT THE AIRPORT KONE solutions for airports Managing the flow of people and goods through airports smoothly and efficiently 7 5 3 8 4 11 KONE solutions for airports 1.
ThyssenKrupp Company Name
synergy ONE WORLD. ONE ELEVATOR. A ThyssenKrupp Elevator Company ThyssenKrupp Company Name TK 1 Nothing above. synergy is the passenger elevator without shaft head. Nothing below. synergy is the passenger
St. John s University
St. John s University Fire Safety Plan Founder s Village Townhouses Page 1 St. John s University Fire Safety Plan Part 1-Building Information Section Founder s Village Townhouses 8000 Utopia Parkway Jamaica
Requirements for Building Application Submission
THE DEVELOPMENT CONTROL AND PLANNING BOARD P O Box 597 Phone: 869 465-2277 Bladen Commercial Development Fax: 869 465-5842 Basseterre, St. Kitts Email: [email protected] To: Architects, Designers
Energy'Saving,'Thermal'Comfort'and'Solar'Power'Information'Sheet'
Energy'Saving,'Thermal'Comfort'and'Solar'Power'Information'Sheet' We ve prepared this information sheet to help you to minimise energy consumption and energy costs while maximising thermal comfort at home.
Fire Pump Plan Review March 2010
Fire Pump Plan Review March 2010 Date of Review: / / Permit Number: Business/Building Name: Address of Project: Designer Name: Designer s Phone: Contractor: Contractor s Phone: Occupancy Classification:
