1 Power management PowerLogic System Catalogue 2004
2 PowerLogic System is PowerLogic System helps you control the cost, quality and reliability of electric power. With PowerLogic System, you can determine where extra capacity exists, identify over-loaded equipment and balance loads on substations, switchboards and other power equipment. By optimising your electrical system, you extend the life of your installation. Introduced more than ten years ago, PowerLogic System has proven its cost-effectiveness and continues to help customers improve their productivity and profitability every day. PowerLogic System is Transparent Ready TM, making full use of web-enabled technology. In this way, our commercial and industrial power distribution expertise spans from single buildings to geographically dispersed enterprise systems. With PowerLogic System, Schneider Electric gives you the best of the New Electric World, where and when you need it.
3 General contents Index of catalogue numbers 2 Why use PowerLogic System? 4 Panorama of the PowerLogic range 8 Examples of architectures 12 Current transformers 14 TI Panel instruments 20 AMP / VLT IM100 / UM100 FRE CI / CH Kilowatt hour meters 33 CE ME Power-monitoring units 40 PM9 PM500 PM700 PM800 CM3000 CM4000 Communication and supervision 92 EGX200 EGX400 MPS100 SMS 1
4 Index of catalogue numbers Cat. no. Description Page CMV voltmeter selector switch, DIN rail CMA ammeter selector, DIN rail Power Meter PM9P (230 V AC) Power Meter PM9C (230 V AC) VLT digital voltmeter, DIN rail AMP direct reading digital ammeter, DIN rail FRE digital frequency meter, DIN rail AMP multi-rating digital ammeter, DIN rail Power Meter PM9P (24 to 48 V DC) Power Meter PM9C (24 to 48 V DC) CH hour counter, DIN rail CI impulse counter, DIN rail CE electromechanical kilowatt hour meter 35 (1P + N) CE electromechanical kilowatt hour meter 35 (3P/3P + N) CEr electromechanical kilowatt hour meter 35 (1P + N) CEr electromechanical kilowatt hour meter 35 (3P/3P + N/400 V) CEr electromechanical kilowatt hour meter 35 (3P/3P + N/230 V) CH hour counter, 48 x 48 mm (24 V AC) CH hour counter, 48 x 48 mm (230 V AC) CH hour counter, 48 x 48 mm (12 to 36 V DC) AMP analog ammeter, 72 x 72 mm, for motor 22 feeders (delivered without dial) AMP analog ammeter, 72 x 72 mm, for standard 22 feeders (delivered without dial) VLT analog voltmeter, 72 x 72 mm Dial, A, for AMP Dial, A, for AMP Dial, A, for AMP Dial, 0-50 A, for AMP Dial, A, for AMP Dial, A, for AMP Dial, A, for AMP Dial, A, for AMP Dial, A, for AMP Dial, A, for AMP Dial, A, for AMP CMA ammeter selector switch, 48 x 48 mm CMV voltmeter selector switch, 48 x 48 mm Dial, A, for AMP AMP analog ammeter for direct connection, 20 DIN rail AMP analog ammeter for connection to TI 20 (delivered without dial), DIN rail Dial, 0-5 A, for AMP Dial, 0-50 A, for AMP Dial, 0-75 A, for AMP Dial, A, for AMP Dial, A, for AMP Dial, A, for AMP Dial, A, for AMP Dial, A, for AMP Dial, A, for AMP Dial, A, for AMP Dial, A, for AMP Dial, A, for AMP Dial, A, for AMP Dial, A, for AMP Dial, A, for AMP VLT analog voltmeter (0-300 V), DIN rail VLT analog voltmeter (0-500 V), DIN rail 20 Cat. no. Description Page AMP analog ammeter, 96 x 96 mm, for motor 23 feeder (delivered without dial) AMP analog ammeter, 96 x 96 mm, for standard 23 feeder (delivered without dial) VLT analog voltmeter, 96 x 96 mm Dial, A, for AMP Dial, A, for AMP Dial, A, for AMP Dial, 0-50 A, for AMP Dial, A, for AMP Dial, A, for AMP Dial, A, for AMP Dial, A, for AMP Dial, A, for AMP Dial, A, for AMP Dial, A, for AMP Dial, A, for AMP Dial, A, for AMP Dial, A, for AMP Dial, A, for AMP Dial, A, for AMP Dial, A, for AMP TI 50/5 tropicalised transformer for cables 15, TI 75/5 tropicalised transformer for cables 15, TI 100/5 tropicalised transformer for cables 15, TI 125/5 tropicalised transformer for cables 15, 16 and busbars TI 150/5 tropicalised transformer for cables 15, 16 and busbars TI 200/5 tropicalised transformer for cables 15, 16 and busbars TI 150/5 tropicalised transformer for busbars TI 200/5 tropicalised transformer for busbars TI 250/5 tropicalised transformer for cables 15, 16 and busbars TI 300/5 tropicalised transformer for cables 15, TI 400/5 tropicalised transformer for cables TI 500/5 tropicalised transformer for cables TI 600/5 tropicalised transformer for cables TI 250/5 tropicalised transformer for busbars TI 300/5 tropicalised transformer for busbars TI 400/5 tropicalised transformer for cables 15 and busbars TI 500/5 tropicalised transformer for cables 15 and busbars TI 500/5 tropicalised transformer for busbars TI 600/5 tropicalised transformer for busbars TI 200/5 tropicalised transformer for busbars TI 250/5 tropicalised transformer for busbars TI 300/5 tropicalised transformer for busbars TI 400/5 tropicalised transformer for busbars TI 500/5 tropicalised transformer for busbars TI 600/5 tropicalised transformer for busbars TI 800/5 tropicalised transformer for busbars TI 1000/5 tropicalised transformer for busbars TI 40/5 tropicalised transformer for cables 15, TI 50/5 tropicalised transformer for cables 15, TI 75/5 tropicalised transformer for cables 15, TI 100/5 tropicalised transformer for cables 15, TI 125/5 standard transformer for cables 15, 16 and busbars TI 150/5 standard transformer for cables 15, 16 and busbars TI 200/5 standard transformer for cables 15, 16 and busbars TI 150/5 standard transformer for busbars 15 2
5 Index of catalogue numbers Cat. no. Description Page Cat. no. Description Page TI 200/5 standard transformer for busbars TI 250/5 standard transformer for cables 15, 16 and busbars TI 300/5 standard transformer for cables 15, TI 400/5 standard transformer for cables 16 and busbars TI 500/5 standard transformer for cables 16 and busbars TI 600/5 standard transformer for cables TI 250/5 standard transformer for busbars TI 300/5 standard transformer for busbars TI 400/5 standard transformer for cables 15 and busbars TI 500/5 standard transformer for cables 15 and busbars TI 500/5 standard transformer for busbars TI 600/5 standard transformer for busbars TI 200/5 standard transformer for busbars TI 250/5 standard transformer for busbars TI 300/5 standard transformer for busbars TI 400/5 standard transformer for busbars TI 500/5 standard transformer for busbars TI 600/5 standard transformer for busbars TI 800/5 standard transformer for busbars TI 1000/5 standard transformer for busbars TI 1250/5 tropicalised transformer for busbars TI 1500/5 tropicalised transformer for busbars TI 1250/5 tropicalised transformer for busbars TI 1500/5 tropicalised transformer for busbars TI 1250/5 tropicalised transformer for busbars TI 1500/5 tropicalised transformer for busbars TI 2000/5 tropicalised transformer for busbars TI 2500/5 tropicalised transformer for busbars TI 3000/5 tropicalised transformer for busbars TI 2500/5 tropicalised transformer for busbars TI 3000/5 tropicalised transformer for busbars TI 4000/5 tropicalised transformer for busbars TI 5000/5 tropicalised transformer for busbars TI 6000/5 tropicalised transformer for busbars Cylinder Ø 8.5 mm for TI transformer Cylinder Ø 12.5 mm for TI transformer Lead-sealable cover for TI transformer Lead-sealable cover for TI transformer ME1 digital watt hour meter ME1z digital watt hour meter ME1zr digital watt hour meter ME4 digital watt hour meter ME4zr digital watt hour meter ME4zrt digital watt hour meter ME3 digital watt hour meter ME3zr digital watt hour meter Micro Power Server MPS UM100 digital voltmeter, 72 x 72 mm UM100 digital voltmeter, 72 x 72 mm UM100 digital voltmeter, 72 x 72 mm IM100 digital ammeter, 72 x 72 mm IM100 digital ammeter, 72 x 72 mm IM100 digital ammeter, 72 x 72 mm Power Meter PM500 (AC/DC) Power Meter PM500 (DC) Modbus RS 485 module for PM IO11 Puls module for PM IO22 Alarm module for PM AO ma module for PM IO02 2 Puls module for PM A AI05 AI05 module for CM Series AI420 AI420 module for CM Series AO420 AO420 module for CM Series C CAB4 CM/display connection cable (1.3 m) 72, 82 CAB12 CM/display connection cable (4.2 m) 72, 82 CAB30 CM/display connection cable (9 m) 72, 82 CM3250MG Circuit Monitor CM CM3350MG Circuit Monitor CM CM4000MG Circuit Monitor CM CM4000TMG Circuit Monitor CM4000T 80 CM4000XRMG Circuit Monitor CM4000XR 80 CM4MEM16M Memory extension kit for CM Series 4000, 16 Mb 83 CM4MEM32M Memory extension kit for CM Series 4000, 32 Mb 83 CMDLCMG CMDLC LCD display for CM Series 3000/ , 82 CMDVFMG CMDVF vacuum fluorescent display 72, 82 for CM Series 3000/4000 CVM CVM current/voltage module for CM CVMT CVMT current/voltage module for CM4000T 83 CVMXR CVMXR current/voltage module for CM4000XR 83 D DI120AC DI120AC module for CM Series DI240AC DI240AC module for CM Series DI32DC DI32DC module for CM Series DO120AC DO120AC module for CM Series DO200DC DO200DC module for CM Series DO240AC DO240AC module for CM Series DO60DC DO60DC module for CM Series E ECC21 Ethernet ECC21 communication card 73, 83 for CM Series 3000/4000 EGX200MG Ethernet EGX200 gateway 94 EGX400MG Ethernet EGX400 server 95 I IOC44 IOC44 card for CM Series 3000/ , 84 IOX IOX extender for CM Series IOX0404 IOX0404 extender for CM Series IOX08 IOX08 extender for CM Series IOX2411 IOX2411 extender for CM Series O OCIVF P OCIVF optical communication interface (CMDVF/PC) PM700MG Power Meter PM PM700PMG Power Meter PM700P 56 PM710MG Power Meter PM PM810MG Power Meter PM PM820MG Power Meter PM PM850MG Power Meter PM PM8M22 PM8M22 module for PM Series PM8M2222 PM8M2222 module for PM Series PM8M26 PM8M26 module for PM Series , 82 3
6 Presentation Why use PowerLogic System? Get all the information you need to manage your electrical installation Today, cost management and improved continuity of service can boost your competitiveness. For this, you need more information concerning the operation of your electrical installation: consumption data, load curves, disturbances, harmonic pollution, available power, etc. PowerLogic System brings you all this information. Information you can count on, where and when you need it. E _A Public buildings PowerLogic System, the metering and monitoring solution PowerLogic System offers a complete, consistent power metering and monitoring solution for optimal management of your electrical installation. A complete solution: b covering all electrical installation management needs, from simple current metering right through to remote monitoring of power quality b backed by the most complete range of metering/monitoring devices and powermonitoring software on the market b suited to the widest variety of applications in both industrial and service sectors. A consistent solution: b integrating all low and medium voltage metering, monitoring and protection devices b offering communication software and gateways pre-configured for easy integration of Schneider Electric devices b at the heart of the Transparent Ready TM concept. Remote monitoring DB Hospitals Communication Semiconductor manufacturers Devices _A Panel instruments Kilowatt hour meters Powermonitoring units LV circuit breakers MV control and protection units Other compatible products Automobile industry PowerLogic System, the metering and monitoring solution suited to the widest variety of applications. A PowerLogic System solution integrates b PowerLogic range products: v metering and monitoring devices, both communicating and non-communicating v communication interfaces v power-monitoring software b Masterpact and Compact circuit breakers equipped with Micrologic control units b Sepam and Vigirex protection relays b any other Modbus-comptabile device 4
7 Presentation Why use PowerLogic System? (cont.) - PowerLogic System, the key to improving your electrical distribution system PowerLogic System serves 3 functions: b collection of measurement data b organisation and transmission of measurement data to facilitate analysis by the different departments concerned: production, maintenance, accounting, site management b checking of the results obtained after implementing electrical distribution system improvement solutions. DB Collect measurement data Devices Communication Remote monitoring Organise measurement data Check Implement solutions Design/ solutions Analysis Improve the distribution system DB Energy costs With PowerLogic System, you control your electrical installation PowerLogic System helps you Reduce energy costs Get a clearer view of your consumption b identification of major consumers and allocation of costs b management of consumption peaks and optimisation of your utility contract. Continuity of service Power quality Improve power quality Increase power-system reliability and optimise your operating costs b monitoring of harmonics b lower maintenance costs b reduced production losses. Improve continuity of service Use the full capacity or your installation b analysis of the electrical distribution system b diagnosis of failures. 5
8 Presentation Why use PowerLogic System? Benefits and applications DB Reduce energy costs PowerLogic System helps you reduce power consumption and the cost of the energy you use through sub-billing and electrical contract optimisation. E87260 Sub-billing and cost allocation to reduce consumption Metering of energy consumption to: b identify major consumers b allocate costs b make users aware of expenditures. E88058 Organisation of measurement data Optimisation of power contract and load curves to reduce energy costs Recording of energy consumption and load curves to: b optimise the power contract b aggregate multi-site costs and negotiate global contracts b identify spare capacity for electrical installation extensions b manage peaks and avoid penalties: v improve power factor by power factor correction solutions v avoid subscribed-power overruns by automatic load-shedding. Monitoring of other utilities Count pulses received from other utility meters (water, gas, steam, etc.) for global, centralised utility management. Trend curves DB Improve power quality Power quality has a direct impact on operating costs: b direct costs: over-consumption due to increased power losses b indirect costs: v production losses: process malfunctions, unnecessary tripping v equipment costs: shorter service life, lower efficiency, oversized equipment. E87257 PowerLogic System lets you assess the quality of your power, identify the causes of any problems and check the effectiveness of remedial measures. Four main functions are used to check power quality: b monitoring of harmonics b detection of voltage sags and swells b detection of transients b EN50160 electricity supply compliance checking. Spectral analysis of harmonics 6
9 Presentation Why use PowerLogic System? Benefits and applications (cont.) E87258 Measurement of total harmonic distortion and individual harmonic content b identify sources of harmonic distortion and separate them from sensitive loads b determine causes of malfunctions b derate power devices (transformers, cables, etc.) b implement filtering solutions. Detection and waveform capture of voltage sags and swells Determine the origin of production losses or shutdowns. Waveform capture triggered by a disturbance Detection and waveform capture of transients Determine the causes of malfunctions and breakdowns. EN50160 electricity supply compliance checking To assess the quality of distributed power according to the European standard EN50160 and check that the distributor complies with the standard. DB Improve continuity of service Electricity is vital to site operation. However, the phenomena that cause faults are not always easy to understand. PowerLogic System gives a better understanding of the electrical distribution system and offers tools for analysis. It lets you manage the system in real time and thereby increase reliability. PE PE Real time monitoring of your electrical installation Panel instrumentation For local display of measurement data and checks on installation operation. Remote monitoring Monitoring of the electrical installation to get the right information to the right person at the right time: b switchgear status and measurements for the facility manager b alarms and events for the maintenance department b cost allocation for the accounting department, etc. Open, flexible communication system allowing intervention by an external expert when required. Transparent access to information via Web technologies With the EGX400 Web server, you can now access all the information you need wherever you are and whenever you want via a standard browser like Internet Explorer. E87264 Access to metering and monitoring data via a Web browser Event and alarm logs Preventive and corrective maintenance Preventive maintenance Detection of problems in advance based on key parameters, to avoid equipment failures and downtime. Corrective maintenance Clear, complete information for the facility manager regarding fault circumstances in order to get power restored as quickly as possible: b local or remote alarms (e.g. by telephone or pager) b fault locating, overall vision, summary tables, etc. Detailed information for experts in charge of analysing the causes of faults and designing solutions to improve the electrical distribution system: b event and alarm logs b waveform capture, etc. 7
10 Product selection guide Panorama of the PowerLogic range Current transformers Panel instruments TI Name AMP / VLT AMP / VLT current transformer Function ammeter, voltmeter ammeter, voltmeter Installation b cable connections b insulated cable, diameter 21 to 35 mm, through transformer b busbar through transformer: v Prisma vertical busbars, 20 x 5 and 32 x 5 mm v insulated flexible busbars, 30 x 10 to 65 x 32 mm v Linergy busbars, 800 A and 1600 A v rigid busbars, 20 x 5 to 55 x 165 mm Technology analog digital Installation Applications Installation monitoring DIN rail 4 x 18 mm modules Panel instrumentation I / U I / U Remote monitoring Advanced remote monitoring Sub-billing and cost allocation Energy consumption Consumption for different time periods Consumption of other utilities Optimisation of power contract and load curves DIN rail 2 x 18 mm modules Power quality analysis Monitoring of harmonics (THD) Analysis of individual harmonic content Detection of voltage sags and swells Detection of transients EN50160 compliance checking Characteristics b transformation ratio: 40/5 A to 6000/5 A b accuracy: class 0.5 to 3 b maximum rated operational voltage: 720 V AC b standard or tropicalised Characteristics Measurement accuracy class 1.5 ± 0.5% ± 1 digit Voltage measurement Current measurement VLT: 500 V AC direct or external VT AMP: 30 A direct or external CT VLT: 600 V AC direct or external VT AMP: 10 A direct or external CT Communication ports Inputs / Outputs Memory capacity page 14 page 20 page 21 8
11 Product selection guide Panorama of the PowerLogic range (cont.) Kilowatt hour meters AMP / VLT IM100 / UM100 FRE CH / CI CE ME ammeter, voltmeter ammeter, voltmeter frequency meter hour counter pulse counter kilowatt hour meter analog digital digital electromechanical electromechanical digital watt hour meter flush mount 72 x 72 mm 96 x 96 mm flush mount 72 x 72 mm DIN rail 2 x 18 mm modules CI, CH: DIN rail 2 x 18 mm modules CH: flush mount DIN rail 6 x 18 mm modules DIN rail 2 or 4 x 18 mm modules I / U I / U F hours / pulses E E class 1.5 ± 1% ± 1 digit ± 0.5% ± 1 digit class 2 class 2 VLT: 500 V AC direct or external VT UM100: 600 V AC direct or external VT 400 V AC direct 400 V AC direct 400 V AC direct AMP: external CT IM100: external CT 63 A direct or external CT 63 A direct or external CT page 22 page 25 page 21 page 29 page 34 page 36 9
12 Product selection guide Panorama of the PowerLogic range (cont.) Power-monitoring units Name PM9P / PM9C PM500 PM700 / PM710 PM810 PM820 / PM850 Function Power Meter Power Meter Power Meter Power Meter Power Meter Technology digital digital digital digital digital Installation DIN rail 4 x 18 mm modules flush mount 96 x 96 mm flush mount 96 x 96 mm flush mount 96 x 96 mm flush mount 96 x 96 mm Applications Installation monitoring Panel instrumentation I, U, F, P, Q, S, PF, E (demand, minimum and maximum values) Remote monitoring Advanced remote monitoring time-stamped alarms time-stamped alarms Sub-billing and cost allocation Energy consumption Consumption for different time periods Consumption of other utilities Optimisation of power contract and load curves Power quality analysis Monitoring of harmonics (THD) Analysis of individual harmonic content Detection of voltage sags and swells Detection of transients EN50160 compliance checking Characteristics Measurement accuracy class 2 (active energy) Voltage measurement 450 V AC direct or external VT class 1 (active energy) 480 V AC direct or external VT class 1 (active energy) 480 V AC direct or external VT class 1 (active energy) 600 V AC direct or external VT class 0.5S (active energy) 600 V AC direct or external VT Current measurement external CT external CT external CT external CT external CT Communication ports Inputs / Outputs 1 O 8 I/O 2 O 16 I/O 16 I/O Memory capacity 80 / 800 kbytes page 44 page 50 page 56 page 62 10
13 Product selection guide Panorama of the PowerLogic range (cont.) Communication and supervision CM3000 CM4000 Name EGX200 EGX400 MPS100 SMS Circuit Monitor Circuit Monitor Function Ethernet gateway digital digital display in front, module inside switchboard display in front, module inside switchboard Installation DIN rail or desktop Ethernet server DIN rail or desktop Ethernet server DIN rail or desktop power-monitoring software Applications Ethernet communication RS 485 / Ethernet gateway and data logs Web server with standard HTML pages Micrologic, PM9C, PM500, PM710, PM800, Sepam CM3000, CM4000 Micrologic, PM500, PM800 Micrologic, PM9C, PM500, PM710, PM800, Sepam CM3000, CM4000 Web server with custom HTML pages Remote monitoring Real time data Historical data Automatic notification Alarm and event logs Waveform display Custom animated graphics Automatic creation of custom reports class 0.5S (active energy) 600 V AC direct or external VT class 0.2S (active energy) 600 V AC direct or external VT Characteristics Ethernet ports Modbus TCP / IP protocol RS 485 (2-wire / 4-wire) ports Modbus protocol external CT external CT Number of devices connected directly 10/100 Base TX port 10/100 Base TX port Base FX port (fiber optics) Base TX port RS 232 configuration ports Miscellaneous b 1 modem port 9 I/O 25 I/O b SMTP client b 6 I / 2 O 8 Mbytes 32 Mbytes page 70 page 80 page 94 page 100 page
14 Product selection guide Examples of architectures PowerLogic System can be used in a number of different architectures depending on the layout of the site. It also offers different user profiles simultaneously. Example 1 b installation in a small building or isolated equipment room b one or more metering/monitoring units connected to a simple PC (directly or via modem) b for electrical installation monitoring by the maintenance department. DB Modbus RS 485 Example 2 b installation in a building with a number of users interconnected by a local Intranet b connection of metering/monitoring units to EGX gateways for integration in the company Ethernet network b for shared management of the electrical installation by different departments: v simple monitoring, with no dedicated software, using a Web browser, v complete power monitoring using SMS software. DB Web browser SMS Ethernet TCP/IP Modbus RS 485 Modbus RS
15 Product selection guide Examples of architectures (cont.) Example 3 b installation in a number of buildings linked by a company Intranet b connection of metering/monitoring units to EGX Web servers for integration in the company Ethernet network b all sectors of the company connected to the Intranet have direct access to essential data on the electrical installation via their Web browser. DB Intranet Web browsers SMS Ethernet TCP/IP Modbus RS 485 Modbus RS
16 Current transformers TI current transformers NMD NMD Function Current transformers with a ratio of Ip/5, for measurement devices (ammeters, kilowatt hour meters), load shedders, control relays, etc. Common technical data b Secondary current: 5 A. b Max. voltage rating Ue: 720 V. b Frequency: Hz. b Safety factor: v 40 to 4000 A: fs y 5 v 5000 to 6000 A: fs y 10. b IP20. b Ambient installation temperature: v standard range: - 5 C to + 55 C, humidity < 95 % v tropicalised range: - 25 C to + 60 C, humidity > 95 %. b Reference standards: IEC 44-1, NFC42502, VDE 0414, BS 7626 and IEC b Weight: NMD Catalogue numbers Weight (g) and and and and and Specific technical data PB TI with let-through primary: b Secondary connection using terminals for lug, using tunnel terminals or using screws (depending on cat. no.). b Delivered with: Catalogue numbers Adapter for fixing on a symmetrical rail Adapter for fixing on a plate Insulated binding screw Sealable cover and b b b and b b b Optional and b b b Optional and b b b and b b b b b b b b b b MD-2 Sealable cover. b Maximum dimensions for primary circuit cable inlets: Catalogue numbers Opening Cable Ø and x 5 mm and x 10 mm and x 10 mm and x 11 mm and 51 x 31 mm and x 32 mm x 84 mm x 127 mm x 127 mm x 165 mm 14
17 Current transformers TI current transformers (cont.) 0 TI with connection of primary by screw and nut: b Secondary connection using terminals for lug or tunnel terminals (depending on cat. no.). b Cylinder Ø 8.5 mm. b Cylinder Ø 12.5 mm. b Delivered with: Catalogue numbers Catalogue numbers (1) Rigid flat busbars. (2) Rigid vertical busbars. (3) < 80 mm rigid busbars. (4) 80 mm rigid busbars. (5) 100 mm rigid busbars. (6) 100 mm rigid triple busbars. Adapter for fixing on a symmetrical rail Adapter for fixing on a plate Sealable cover and b b b and b b Optional TI with let-through primary Ratio Insulated Prisma cable vertical busbars Insulated flexible busbars Linergy vertical busbars Rigid busbars Cat. no. TI standard Cat. no. TI tropical 40/5 b /5 b /5 b /5 b /5 b b /5 b b b b /5 b b b b b /5 b b b b b /5 b b b b b /5 b b b b b /5 b b b b /5 b b (1) b b b (2) /5 b b b /5 b b b /5 b b b (3) b (4) b (5) /5 b (3) b (4) b (5) /5 b /5 b b (6) /5 b b (6) /5 b /5 b /5 b
18 Current transformers TI current transformers (cont.) 0 Catalogue numbers TI with connection of primary by screw and nut Ratio Cat. no. TI standard Cat. no. TI tropical Cat. no. cylinder 40/ / or / or / or / or / or / or / or / or / or / or / or Accessories Type Cat. no. Cylinder Ø 8.5 mm Ø 12.5 mm Sealable cover for cat. nos to and to for cat. nos to and to Connection E56648 S1 S2 K L P1 K E56651 K P2 TI with let-through primary. E56646 E56647 S1 S2 K L P1 K S1 S2 K L P1 K TI with connection of primary by screw and nut. 16
19 Current transformers TI current transformers 0 Choice and accuracy class Choosing a current transformer 2 criteria exist for choosing a TI: b the Ip/5 A ratio b the type of installation. The Ip/5 A ratio It is recommended that a ratio immediately above the measured current (In) be chosen. Example: In = 1103 A; ratio chosen: 1250/5. Type of installation Which TI model to choose depends on the type of installation: b insulated cables b Prisma vertical busbars b insulated flexible busbars b Linergy vertical busbars b rigid busbars. Important warning Never open the secondary circuit of a current transformer while the primary circuit is energized. Before any kind of maintenance service on the secondary circuit, the secondary terminals on the tranformer must be short-circuited. Determining the accuracy class of a TI The accuracy class is a function of the transformer's power and the consumption of the measurement system. The latter takes device and cable consumption into account. For a given accuracy class, consumption of the measurement system must not exceed the power on the TI transformer. Copper cable cross-section in mm 2 Power in VA per doubled meter at 20 C For each temperation variation of 10 C, the power absorbed by the cables rises by 4 %. Merlin Gerin device Consumption in VA Ammeter 72 x 72 / 96 x Analog ammeter 1.1 Ammeter Digipact IM Digital ammeter 0.3 PM500, PM700, PM800, CM3000, CM CE tri 1.2 CEr tri 1.2 ME4zrt 0.05 PM
20 Current transformers TI current transformers 0 Choice and accuracy class (cont.) Example: consumption of a measurement system at 20 C PM VA Digital ammeter VA 4 meters of doubled wire 2.5 mm VA Measurement system consumption = 2.19 VA The accuracy class of the TI is deduced: b class 3 for a TI with a ratio of 75/5 b class 1 for a TI with a ratio of 100/5 b class 0.5 for a TI with a ratio of 125/5. Ip/5 Cat. no. Power (VA) accuracy class standard TI tropical TI A A A A A A A A A A A A A A A A A A A A A A
21 Current transformers Dimensions 0 TI current transformers E58377 E58380 E58383 Cat. no to 16506, to Cat. no to 16515, to Cat. no to 16521, to E58376 E58379 E58382 Cat. no and 16524, and Cat. no to 16535, to Cat. no and E58375 E58378 E58381 Cat. no to Cat. no to Cat. no and Cylinders E90390 E90391 Cat. no Cat. no
22 Panel instruments DIN rail analog ammeters and voltmeters 0 Function AMP Ammeters measure the current flowing through an electric circuit in amps. VLT Voltmeters measure the potential (voltage) difference of an electric circuit in volts AMP. VLT. Common technical data b Accuracy: class 1.5. b Complies with standards IEC 51 and IEC 414. b Ferromagnetic device. b Pseudo-linear scale over 90. b Ammeters (except catalogue number 16029): v connection on TI, ratio In/5, to be ordered separately v interchangeable dials. b Temperature: v operating temperature: C. v reference temperature: 23 C. b Influence of temperature on accuracy: ± 0.03 % / C. b Utilisation frequency: 50/60 Hz. b Consumption: v AMP: 1.1 VA v VLT catalogue number 15060: 2.5 VA v VLT catalogue number 16061: 3.5 VA. b Permanent overload: v AMP: 1.2 In v VLT: 1.2 Un. b Maximum overload for 5 s: v AMP: 10 In v VLT: 2 Un. b Connection: tunnel terminals for 1.5 to 6 mm 2 rigid cables. Catalogue numbers Type Scale Connection with TI AMP with direct connection Width in mod. of 9 mm Cat. no A no AMP with connection on TI Basic device X/ (delivered without dial) Dial 0-5 A A 50/ A 75/ A 100/ A 150/ A 200/ A 250/ A 300/ A 400/ A 500/ A 600/ A 800/ A 1000/ A 1500/ A 2000/ VLT V V
23 Panel instruments DIN rail digital ammeters, voltmeter and frequency meter 0 Function E57571 AMP Ammeters measure in amps the current flowing through an electric circuit. VLT Voltmeters measure in volts the potential (voltage) difference of an electric circuit. FRE The frequency meter measures in hertz the frequency of an electric circuit. E57572 AMP. Common technical data b Supply voltage: 230 V. b Operating frequency: 50/60 Hz. b Display by red LED: 3 digits. b Accuracy at full-scale : 0.5 % ±1 digit. b Consumption: 0.3 VA. b Connection: tunnel terminals for 2.5 mm 2 cables. Specific data E57573 VLT. FRE. 10 A direct reading ammeter b Minimum value measured: 4 % of rating. b Measurement input consumption: 1 VA. Multi-rating ammeter b Ratings: v in direct reading: 5 A v by CT (not supplied) configurable on the front face of the ammeter: 10, 15, 20, 25, 40, 50, 60, 100, 150, 200, 250, 400, 500, 600, 800, 1000, 1500, 2000, 2500, 4000, 5000 A. b Minimum value measured: 4 % of rating. b Measurement input consumption: 0.55 VA. Voltmeter b Direct measurement: V. b Input impedance: 2 MΩ. b Minimum value measured: 4 % of rating. Frequency meter b Minimum value measured: 20 Hz. b Maximum value measured: 100 Hz. b Full-scale display: 99.9 Hz. Compliance with standards b Safety: IEC EN b EMC electromagnetic compatibility: IEC EN and IEC EN Catalogue numbers Type Scale Connection with TI Direct reading AMP Multi-rating AMP VLT FRE Width in mod. of 9 mm Cat. no A No A As per rating V Hz
24 Panel instruments 72 x 72 analog ammeters and voltmeter 0 PB Function The 72 x 72 measurement devices are designed for flush-mounted installation on doors, wicket doors and front plates of enclosures and cubicles. AMP The ammeters measure in amps the current flowing through an electrical circuit. VLT The voltmeter measure in volts the potential difference (voltage) of an electrical circuit. PB AMP for standard feeder. AMP for motor feeder. Common technical data b Accuracy: class 1.5. b Compliance with standards NF C IEC 414. b Ferromagnetic device. b Scale length: 62 mm over 90. b Mounting in enclosure or in cubicle. b IP52. b Maximum operating position: 30 /vertical. b Temperature: v operation: -25 C to +50 C v reference: 23 C. b Influence of temperature on accuracy: ±0.003 % / C. b Utilisation frequency: 50/60 Hz. PB AMP specific technical data b Needs a In/5 Tl to be ordered separately. b Interchangeable dials to be ordered separately. b Consumption: 1.1 VA. b Permanent overload: 1.2 In. b Maximum overload for 5 s: 10 In. VLT. VLT specific technical data b Consumption: 3 VA. b Permanent overload: 1.2 Un. b Maximum overload for 5 s: 2 Un. Catalogue numbers Type Scale Connection Cat. no. on TI AMP for standard feeder Basic device (delivered without dial) X/ In dial 0-50 A 50/ A 100/ A 200/ A 400/ A 600/ A 1000/ A 1250/ A 1500/ A 2000/ AMP for motor feeder Basic device (delivered without dial) X/ In dial A 30/ A 75/ A 200/ VLT V
25 Panel instruments 96 x 96 analog ammeters and voltmeter 0 PB Function The 96 x 96 measurement devices are designed for flush-mounted installation on doors, wicket doors and front plates of enclosures and cubicles. AMP The ammeters measure in amps the current flowing through an electrical circuit. VLT The voltmeter measure in volts the potential difference (voltage) of an electrical circuit. PB AMP for standard feeder. Common technical data b Accuracy: class 1.5. b Compliance with standards NF C IEC 414. b Ferromagnetic device. b Scale length: 80 mm over 90. b Mounting in enclosure or in cubicle. b IP52. b Maximum operating position: 30 /vertical. b Temperature: v operation: -25 C to +50 C v reference: 23 C. b Influence of temperature on accuracy: ±0.003 % / C. b Utilisation frequency: 50/60 Hz. PB AMP for motor feeder. AMP specific technical data b Needs a In/5 Tl to be ordered separately. b Interchangeable dials to be ordered separately. b Consumption: 1.1 VA. b Permanent overload: 1.2 In. b Maximum overload for 5 s: 10 In. VLT specific technical data b Consumption: 3 VA. b Permanent overload: 1.2 Un. b Maximum overload for 5 s: 2 Un. Catalogue numbers VLT. Type Scale Connection Cat. no. on TI AMP for standard feeder Basic device (delivered without dial) X/ In dial 0-50 A 50/ A 100/ A 200/ A 400/ A 600/ A 1000/ A 1250/ A 1500/ A 2000/ A 2500/ A 3000/ A 4000/ A 5000/ A 6000/ AMP for motor feeder Basic device (delivered without dial) X/ In dial A 30/ A 75/ A 200/ VLT V
26 24
27 Panel instruments 72 x 72 IM100 digital ammeters Function The IM100 is a digital ammeter designed to measure AC currents. It provides front panel readings on switchboards and is not equipped for communication. A single device covers current-transformer ratings from 5 to 8000 A. Characteristics Electrical characteristics Type of measurement rms up to the 9th harmonic Ratings of associated current transformers 5 to 8000 A (1) Frequency Hz Measurement accuracy (not including sensors) ±1 % of full scale, ±1 digit Digital display 4-digit LED (9999 full-scale count) Display-refresh time 1.5 s Consumption On power supply 3.5 VA max On current transformer 0.5 VA at In Overload capacity Continuous 2 In 3 seconds 6 In Electrical safety as defined by standard IEC Supply voltage V AC / DC V AC V AC Mechanical characteristics Dimensions DIN 72 x 72 mm Weight 0.25 kg Degree of protection (EN50102) Front face IP50 Other faces IP30 (IP20 for connections) Front face impact resistance (EN50102) IK07 (2 Joules) Vibrations (IEC ) Fc test 2 to 13.2 Hz - 1 mm 13.2 to 100 Hz g Environment Operating temperature range -20 C to +70 C Storage temperature range -35 C to +85 C Damp heat (IEC ) 6 cycles +25 C/ +55 C / RH 95 % Salt mist (IEC ) Kb test, severity level 2 Electromagnetic compatibility: b electrostatic discharges (IEC ) Level IV b radiated susceptibility (IEC ) Level III b low-energy conducted susceptibility (IEC ) Level IV b high-energy conducted susceptibility (IEC ) Level IV b conducted and radiated emissions (EN ) Class A (1) Associated current transformers: secondary output 5 A. Available primary ratings: Recommended accuracy class: 1 (as defined by IEC ). Accessories DB Connection For measurements on a 3-phase distribution system, the Digipact IM100 ammeter may be combined with a Telemecanique K1F-003M or Multi 9 4-position CMA ammeter selector switch (cat. no and 16017). Installation b on front plate for Prisma cubicle: cat. no or b on door with cut-outs for Prisma cubicle: cat. no Catalogue numbers Voltage (V) Cat. no. 48 to 155 V AC / DC to 240 V AC to 415 V AC
28 Panel instruments 72 x 72 UM100 digital voltmeters Function The UM100 is a digital voltmeter designed to measure AC voltages. It provides front panel readings on switchboards and is not equipped for communication. A single device covers all alternating voltages from 0 to 690 V. Characteristics Electrical characteristics Type of measurement Measured voltage without voltage transformer Frequency Measurement accuracy (not including sensors) Digital display Display-refresh time Consumption Input impedance rms up to the 9th harmonic 0 to 690 V Hz ±1 % of full scale, ±1 digit 3-digit LED (999 full-scale count) 1.5 s 3.5 VA max > 1 MΩ Overload capacity Continuous 1.2 Un 1 second 2 Un Electrical safety as defined by standard IEC Supply voltage V AC / DC V AC V AC Mechanical characteristics Dimensions DIN 72 x 72 mm Weight 0.25 kg Degree of protection (EN50102) Front face IP50 Other faces IP30 (IP20 for connections) Front face impact resistance (EN50102) IK07 (2 Joules) Vibrations (IEC ) Fc test 2 to 13.2 Hz - 1 mm 13.2 to 100 Hz g Environment Operating temperature range -20 C to +70 C Storage temperature range -35 C to +85 C Damp heat (IEC ) 6 cycles +25 C/ +55 C / RH 95 % Salt mist (IEC ) Kb test, severity level 2 Electromagnetic compatibility: b electrostatic discharges (IEC ) Level IV b radiated susceptibility (IEC ) Level III b low-energy conducted susceptibility (IEC ) Level IV b high-energy conducted susceptibility (IEC ) Level IV b conducted and radiated emissions (EN ) Class A Accessories DB Connection For phase-to-phase or phase-to-neutral measurements on a 3-phase distribution system, the Digipact UM100 voltmeter may be combined with a Telemecanique K1F-027M or Multi 9 7-position CMV voltmeter selector switch (cat. no and 16018). Installation b on front plate for Prisma cubicle: cat. no or b on door with cut-outs for Prisma cubicle: cat. no Catalogue numbers Voltage (V) Cat. no. 48 to 155 V AC / DC to 240 V AC to 415 V AC
29 Panel instruments DIN rail CMA and CMV selector switches CMA. CMV. Function CMA This 4-position ammeter selector switch uses a single ammeter (using current transformers) for successive measurement of the currents of a three-phase circuit. CMV This 7-position voltmeter selector switch uses a single voltmeter for successive measurement of voltages (phase-to-phase and phase-to-neutral) of a three-phase circuit. Common technical data b Rotary handle. b Maximum operating voltage: 440V, 50/60 Hz. b Nominal thermal current: 10 A. b Operating temperature: -20 C to +55 C. b Storage temperature: -25 C to +80 C. b Mechanical durability (AC21A-3x440 V): operations. b Electrical durability: operations. b Connection: jumper terminals with captive screws, for cables up to 1.5 mm 2. b Complies with standards: v IEC (EN ) v VDE 0660 part. 107 v UL. Catalogue numbers Type Rating (A) Voltage (V CA) Width in mod. of 9 mm Cat. no. CMA CMV Connection DB N S1 S2 S1 S2 S1 S CMA 3 9 A L3 0 + L2 L1 DB N CMV 1 3 V L1.2 0 L1.N L2.3 L2.N L3.1 + L3.N CMA. CMV. 27
30 Panel instruments 48 x 48 CMA and CMV selector switches CMA. Function The 48 x 48 selector switches are designed for flush-mounted installation on doors, wicket doors and front plates of enclosures and cubicles. CMA The ammeter selector switch uses a single ammeter (by means of current transformers) for successive measurement of the currents of a three-phase circuit. CMV The voltmeter selector switch uses a single voltmeter for successive measurement of the voltages (phase-to-phase and phase-to-neutral) of a three-phase circuit Common technical data b Durability: v electrical: operations v mechanical: operations. b AgNi contact. b Operating temperature: -25 C to +50 C. CMV. Catalogue numbers Type Rating (A) Voltage (V) Number of positions Cat. no. CMA CMV
31 Panel instruments CH hour counters Function Electromechanical counter that counts the operating hours of a machine or piece of electrical equipment. Giving a precise indication of operating time, the counter is used to decide when to carry out preventive maintenance. Common technical data b Electromechanical display. b Maximum display: hours. b Display accuracy: 0.01 %. b Without reset. b Storage temperature: -25 C to +85 C. b Connection: tunnel terminals for 2.5 mm 2 cable CH "DIN". CH "48 x 48". Specific technical data CH "DIN" b Consumption: 0.15 VA. b Operating temperature: -10 C to +70 C. b Mounting on DIN rail. CH "48 x 48" b Consumption: v 15607: 0.25 VA v 15608: 0.15 VA v 15609: 0.02 VA to 12 V and 0.3 VA to 36 V. b Operating temperature: -20 C to + 70 C. b Degree of protection: IP65 on front face. b Mounting on front face of monitoring switchboards. Catalogue numbers Type Voltage (V) Width in mod. of 9 mm Cat. no. CH "DIN" 230 V AC/50 Hz CH "48 x 48" 24 V AC/50 Hz V AC/50 Hz to 36 V DC Connection E91446a E91504 CH 2 3 CH + - load load CH "DIN". CH "48 x 48". 29
32 30
33 Panel instruments CI impulse counter Function Electromechanical counter designed to count impulses emitted by: kilowatt hour meters, temperature overrun detectors, people meters, speed meters, etc. Common technical data b Supply and metering voltage: 230 V AC, 50/60 Hz. b Consumption: 0.15 VA. b Maximum display: impulses. b Without reset. b Metering data: v minimum impulse time: 50 ms v minimum time between 2 impulses: 50 ms. b Storage temperature: -25 C to +85 C. b Operating temperature: -10 C to +70 C. b Connection: tunnel terminals for 2.5 mm 2 cable. Catalogue number Type Width in mod. Cat. no. of 9 mm CI Connection E91445a CI 2 3 load CI 2 3 kwh load 31
34 Panel instruments Dimensions 0 Analog ammeters and voltmeters DB Digital ammeters, voltmeter and frequency meter DB DIN rail CMA and CMV selector switches DB x 72 analog ammeters and voltmeter DB Protection cover Terminal M4 96 x 96 analog ammeters and voltmeter Protection cover DB Terminal M4 32
35 Panel instruments Dimensions (cont.) 0 48 x 48 CMA and CMV selector switches DB (or 4.8) 24.1 (or 33) 22.3 (or 30.5) (with adapter) UM100 voltmeter, IM100 ammeter DB CI impulse counter and CH hour counter DB x 48 CH hour counters DB
36 34
37 Kilowatt hour meters Selection guide for kilowatt hour meters 0 Function Class 2 watt hour meters are designed for sub-distribution metering. They meter the electric power consumed per hour by a single-phased or three-phased electrical circuit, with or without a distributed neutral. Watt hour meters are divided into two large families: b meters with electro-mechanical displays: the CE range b meters with digital displays: the ME range. They have a total meter and some have a partial meter with the RESET function. Both of the ranges can conduct direct measurements, or can use current transformers to measure. ME range is conform to the IEC 1036 standard (with sealable enclosure). Selection guide for watt hour meters CE and ME CE CE CE ME1 ME3 ME4 ME4zrt CEr CEr CEr ME1z ME3zr ME4zr 1P 3P 230 V 3P 400 V ME1zr Operation Single-phased b b Three-phased b b b b Three-phased + neutral b b b b Rated voltage 230 V (1P+N) b b 230 V (3P) b b b 400 V (3P) b b b 127/230 V (3P+N) b 230/400 V (3P+N) b b b Frequency (50/60 Hz) b b b b b b b Direct measurement current (A) For single-phased 25 or For three-phased Current measurement via CT (A) 50 to to to 6000 Total meter b b b b b b b Total meter capacity MWh MWh MWh MWh MWh MWh with CT y 150 A: MWh with CT > 150 A: MWh Partial meter (with RESET) b (ME1z/ME1zr) b (ME3zr) b (ME4zr) b Display Electro-mechanic (6 significant digits b b b in kwh) Digital (5 significant digits b b b b in kwh or MWh) Remote transfer b (CEr) b (CEr) b (CEr) b (ME1zr) b (ME3zr) b (ME4zr) b Width in modules of 9 mm
Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800
Power-monitoring unit PowerLogic System Technical data sheet 2003 Power Meter Series 800 Function and characteristics PB100313 The PowerLogic Power Meter Series 800 offers all the high-performance measurement
More informationPower Meter Series 700
PowerLogic power-monitoring units Power Meter Series 700 Technical data sheet 2007 Functions and characteristics E90463 The PowerLogic Power Meter Series 700 offers all the measurement capabilities required
More informationElectrical Network Management System
Electrical Network Management System Optimisation of the electrical network Measure to understand Understand to control Control to optimise Cost of power and fluids Power quality Power availability 2 Improvement
More informationA project to optimise quality and energy efficiency must include metering
EMDX 3 : Energy Metering A project to optimise quality and energy efficiency must include metering Metering upstream identifies the critical points and ensures optimum targeting of the actions to be taken,
More informationCommunicate and view data from meters with one simple device
Communicate and view data from meters with one simple device PowerLogic EGX300 integrated gateway-server Web Monitoring Communications Plug and Play Plug into your energy usage with a simple mouse click
More informationGain energy insight and control with PowerLogic. PowerLogic EGX300 integrated gateway-server
Gain energy insight and control with PowerLogic PowerLogic EGX300 integrated gateway-server Plug into your energy usage with a simple mouse click The PowerLogic EGX300 is an integrated gateway-server that
More informationQuick Connect. quick - simple - efficient. www.g-mw.de
Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power
More informationRISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:
Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog
More informationPower Meter Series 800
PowerLogic power-monitoring units Power Meter Series 800 Technical data sheet 2007 Functions and characteristics E90463 PB101813-51 PB101823-50 DB111799 Front view of Power Meter Series 800 meter with
More informationApplications. diris_826_a_1_gb_cat
Measurement units NEW diris_824_a_1_cat Energy monitoring and management of low voltage/ high voltage electrical installations Function are measurement units which can provide all the functions offered
More informationVoltage Regulator SPAU 341 C. Product Guide
Issued: July 1998 Status: Updated Version: D/25.04.2006 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations
More information72 x 72 analogue ammeters and voltmeter
72 x 72 analogue ammeters and voltmeter PB101118-30_c Function The 72 x 72 measurement devices are designed for flush-mounted installation on doors, wicket doors and front plates of enclosures and cubicles.
More informationFeatures. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D
7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values
More informationDRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters
The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual
More informationJNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
More informationSpecification guide no. 9 Active harmonic conditioner from 20 to 480 A
Active harmonic conditioner from 20 to 480 A Contents 1 - Installations concerned... 2 1.1 - New installations... 2 1.2 - Existing installations... 2 2 - General... 2 2.1 - Scope... 2 2.2 - Applicable
More informationTRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY
TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY 2 TRACTION NETWORK MONITORING AND PROTECTION SYSTEM Traction network monitoring and protection system,
More informationscalable data centre energy management solution
scalable data centre energy management solution scalable data centre energy management solution EcoMeasure - Scalable Data Centre Energy Management & Efficiency Measurement Solution by Workspace Technology
More informationRISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER
Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.
More informationThermistor motor protection
Thermistor motor protection CM-E Range Thermistor motor protection Thermistor motor protection relays Benefits and advantages Selection table Operating principle and fields of application for thermistor
More informationElectronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
More informationElectronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
More informationPower quality monitoring and analysis with reliability
Power quality monitoring and analysis with reliability PowerLogic CM4000 series circuit monitors Buildings Industry Data Center Intelligent metering and control devices Whether in offices, classrooms,
More informationTemperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)
Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,
More informationThree-phase monitoring relay CM-PFE
Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics
More informationABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.
1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay
More informationVoltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationRM17TE 183...528 V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC
Characteristics multifunction control relay RM17-TE - range 183..528 V AC Complementary Reset time Maximum switching voltage Minimum switching current Maximum switching current [Us] rated supply voltage
More informationABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories
2CDC 251 014 F0t09 Features Monitoring of three-phase mains for grid feeding Type-tested in accordance with DIN V VDE V 0126-1-1: February 2006 Neutral conductor connection configurable Can also be used
More informationVoltage monitoring relays CM-ESS.M For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationPower Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1
Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input
More informationRM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
More informationCONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.
425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and
More information3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance
SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132
More informationISIO 200. Binary Input/Output (I/O) Terminal with IEC 61850 Interface
ISIO 200 Binary Input/Output (I/O) Terminal with IEC 61850 Interface Compact and Easy ISIO 200 Put your Binary I/Os where you need them ISIO 200 is a simple and versatile binary I/O terminal with IEC 61850
More informationRemote Monitoring and REC 501 Control Unit Product Guide
Remote Monitoring and Control Unit REC 501 Product Guide Issued: May 1999 Status: Updated Version: B/06.11.2001 Data subject to change without notice Features Remote control and monitoring unit for the
More informationMILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)
MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed
More informationWaveguide Access Point WGA631. Product Guide
Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................
More informationThe complete range of consumer switchboards and switchgear
Power Distribution The complete range of consumer switchboards and switchgear www.nhp.com.au/mod6 The MOD6 range of consumer switchboards and switchgear is specifically designed for domestic and commercial
More informationThermal-Magnetic Circuit Breaker 3120-...-M1-..
Thermal-Magnetic Circuit Breaker -...-M-.. Description Single or two pole rocker switch/thermal-magnetic circuit breaker with trip-free mechanism (S-type TM CBE to EN 34). The addition of a magnetic tripping
More informationThermistor motor protection relays CM-MSS.22 and CM-MSS.23
Data sheet Thermistor motor protection relays CM-MSS.22 and CM-MSS.23 The thermistor motor protection relays CM-MSS.22 and CM-MSS.23 monitor the winding temperature of motors and protect them from overheating,
More informationMaximum Demand Control
Maximum Demand Control There are three terms that appear on the majority of electric company bills: Active energy consumption (kwh) Reactive energy consumption (kvarh) Maximum Demand Traditionally, utility
More informationR.C.C.B. s two-pole LEXIC
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...
More informationElectronic Control Devices The European Product Catalogue 2007
FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,
More informationRM35UA13MW. range 15..600 V. Main. Product or component type. Relay monitored parameters
Characteristics multifunction voltage control relay RM35-U - range 15..600 V Complementary Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Power consumption in W Main
More informationElectronic Control Devices The European Product Catalogue 2007
FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically
More informationThyristor-controlled power supplies and battery chargers
Thyristor-controlled power supplies and battery chargers Input voltage: 115 / 230 VAC, single phase, 50 / 60 Hz or 208 / 400 / 480 VAC, three phases, 50 / 60 Hz Output voltage: 12 / 24 / 48 / 60 / 72 /
More informationHSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: HSP@hsshsp.de NTG-3000.
NTG-3000 Transducer Data Sheet Document Version 2.8 Page 1 of 10 Versions / Revisions: Document Creation Author Description version date 2.0 2012-07-25 P. Compensis First official version 2.1 2012-08-24
More informationYour automation should be permanently supplied Our compact PROeco power supplies offer that as part of an economical concept Let s connect.
Your automation should be permanently supplied Our compact PROeco power supplies offer that as part of an economical concept Let s connect. Power supply Find the cost-effective solution for your power
More informationDigital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
More informationArc Terminator Active Arc-Resistant Switchgear
Arc Terminator Active Arc-Resistant Switchgear Increasing safety and productivity by extinguishing internal arcing faults within the switchgear. The Square D Arc Terminator from Schneider Electric offers
More informationInstruction Bulletin. MCS025 Sync-Check Module Installation Sheet
Instruction Bulletin 63230-216-244B1 LaVergne, TN, USA MCS025 Sync-Check Module Installation Sheet Retain for future use. DANGER HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Only qualified electrical
More informationAutomation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
More informationLow Voltage Products
Low Voltage Products ABB Power Quality Filters: The most efficient solution for active filtering of harmonics, smooth reactive power compensation and load balancing. Enabling trouble-free and efficient
More informationSYSTEM MONITORING Locally and remotely
StecaGrid 300 StecaGrid 500 StecaGrid 2000+ StecaGrid 2010+ StecaGrid 2020 StecaGrid 3000 StecaGrid StecaGrid 4200 StecaGrid StecaGrid 10000+ 3ph StecaGrid 8000 3ph StecaGrid 10000 3ph monitoring StecaGrid
More informationAccess valuable energy and power information from your system
Access valuable energy and power information from your system PowerLogic Web-Enabled Network Components Buildings Industry Data Center PowerLogic Network Solutions Schneider Electric offers the Square
More informationType: EASY719 DC RC Article No.: 274119. Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description
Type: EASY719 DC RC Article.: 274119 Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
More informationVoltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationPanel Meters and Controllers Modular Panel Meter Type EDM 35
Panel Meters and Controllers Modular Panel Meter Type EDM 35 Modular digital panel meter, 3 1/2-digit Indicating or controlling current, voltage, resistance, temperature, tacho or frequency. Easy programming
More information38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.
38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC
More information38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical
More informationM2M The measure of efficiency
M2M The measure of efficiency The importance of control Measurement and advanced analysis of electrical parameters To make equipment as efficient as possible, it is essential to know the details of its
More informationPowerLogic power-monitoring units. PM5350 power meter. Technical data sheet
PowerLogic power-monitoring units PM5350 power meter Technical data sheet Mid-range metering PM5350 Functions and characteristics PE86278 The PowerLogic PM5350 power meter offers all the measurement capailities
More informationCurrent valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
More informationRelion 605 series. Self-powered feeder protection REJ603 Product Guide
Relion 605 series Relion 605 series Relion 605 series Self-powered feeder protection Product Guide Product version: 3.0 Contents 1.... 3 2. Relay functions... 3 3. Protection functions... 4 4. Application...
More informationPCS0100en 02.2008. Persy Control Services B.V. Netherlands
P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for
More informationCurrent transformers (CT) & Shunts
Current transformers (CT) & Shunts Genreal overview LV CURRENT TRANSFORMERS Product selection guide Standard industrial transformers?????? TCR - TCRO range NEW 9 9 9 Current summation JVM 0 9 TCR usbar
More informationSingle-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable
Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window
More informationAnalog signal converters CC-E I/I Current / current isolators
ata sheet Analog signal converters CC-E I/I Current / current isolators The CC-E I/I is an isolator for the electrical isolation of current signals without auxiliary supply. It allows the isolation between
More informationShort Form Catalogue. Alarm Systems. Reliable Supervision and Control
Short Form Catalogue Alarm Systems Reliable Supervision and Control Alarm Monitors and Indicators The SELCO product range includes a number of alarm monitors and indicator panels for use in numerous applications.
More information38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A
38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays
More informationABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw
Solar inverters ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw PV energy, combined with energy storage systems, can help increase self-consumption and energy selfsufficiency*. One of the biggest challenges
More informationSimple Electrical Utility Cost Allocation Solutions
Simple Electrical Utility Cost Allocation Solutions PowerLogic High Density Metering Advanced Submetering and Multi-Tenant Metering Buildings Retail Multi Residential DATA CENTER SOLUTIONS For More Information:
More informationLTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification
08/17/12 Rev2 LTR Series General Specification 700 VA to 2.1 KVA 1.0 General LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA General Specification This specification describes the features and
More informationModel 8220. POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter
Special product features '''' ENERGY METER ''' MEASURES RPM POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter Model A measurement tool for electrical parameters and distribution network disturbances
More informationEnergy Management Energy Meter Type EM23 DIN
Energy Management Energy Meter Type EM23 DIN Class 1 (kwh) according to EN62053-21 Class B (kwh) according to EN50470-3 Class 2 (kvarh) according to EN62053-23 Accuracy ±0.5 RDG (current/voltage) Energy
More informationOZW30. Central Unit SYNERGYR
2 841 SYNERGYR Central Unit OZW30 Collects billing data from the apartments. Generates an image of each apartment's heat consumption and makes it available for readout. Acts on room temperature control
More informationHEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR
HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR 2 MB 103 TRANSFORMER TEMPERATURE CONTROL UNIT WITH CONTROL SIGNAL Recent approval of new
More informationMasterINTERFACE 39 Series - Relay interface modules
MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy
More informationSENTRON Switching and Protection Devices Air Circuit Breakers
Siemens AG 9 SENTRON Switching and rotection Devices Air Circuit reakers 5 5/ Introduction 3WL Air Circuit reakers 3WL Air Circuit reakers/ Non-Automatic Air Circuit reakers up to 63 A (AC) 5/6 General
More informationReyrolle Protection Devices. 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy
Reyrolle Protection Devices 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy Siemens Protection Devices Limited 2 7PG17 XR101 & XR102 Intertripping Relay
More informationCapacitor Protection Relay SPAJ 160 C. Product Guide
Issued: April 1999 Status: Updated Version: C/19.04.2006 Data subject to change without notice Features One-, two- and three-phase overload stage with definite time characteristic One-, two- and three-phase
More informationProcess Alarm Solutions
Process Alarm Solutions Reliable Supervision and Control www.selco.com SELCO flexible alarm panels for supervision and control SELCO provides efficient and reliable solutions for alarm monitoring of electrical
More informationSURGE PROTECTIVE DEVICES
SURGE PROTECTIVE DEVICES 1. INTRODUCTION In order to ensure safety of people, protection of equipment and, to a certain extent, continuity of supply, insulation co-ordination aims at reducing the likelihood
More informationH/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.
Application : The transducer RISH CON - CA/CV (Fig.1) converts a sinusoidal AC Current or AC Voltage into a load independent DC Current or a load independent DC Voltage proportional to the measured value.
More informationBulletin 150 SMC Flex Smart Motor Controller Specifications
Specifications Specifications Standard Features Optional Features Installation Setup Communications Power Wiring Control Wiring Keypad Software Starting and Stopping Modes Protection and Diagnostics Metering
More informationPowerLogic communication devices. EGX100 Ethernet gateway EGX300 Integrated gateway-server. Technical data sheet
PowerLogic communication devices EGX100 Ethernet gateway EGX300 Integrated gateway-server Technical data sheet 2011 PowerLogic EGX100 Ethernet gateway PE86138 Function The EGX100 serves as an Ethernet
More informationHow To Use A Powerbook 2.2 (Powerbook 2) For Free On A Computer Or Ipad (Powerware) For A Week Or Two (For A Week) For $99.99 (For An Extended Period Of Time)
100% electricity Digital multimeters and power analyzers series DIGITAL MULTIMETERS AND POWER ANALYZERS with backlit graphic LCD screen For the control of energy distribution systems detecting when problems
More informationUser Manual V1.0 2014 SDM220MODBUS. Single-Phase Two Module DIN rail Meters
SDM220MODBUS Single-Phase Two Module DIN rail Meters Measures kwh, Kvarh, KW, Kvar, KVA, PF, Hz, dmd, V, A, etc. Di-directional measurement IMP & EXP Two pulse outputs RS485 Modbus Din rail mounting 36mm
More information33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application
33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection
More informationHow Do You Reduce Energy Costs And Prolong The Life Of Your Equipment?
How Do You Reduce Energy Costs And Prolong The Life Of Your Equipment? PowerLogic PM800 series power meters Buildings Industry Data Center Compact power, energy and power quality meters The Square D PowerLogic
More informationDRM75A 230V 20/100A DIN rail single phase two wire energy meter
DRM75A 230V 20/100A DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation
More informationClimasys Thermal Management System. Schneider Electric Universal Enclosures 2009
Climasys Thermal Management System Schneider Electric Universal Enclosures 2009 Schneider Electric Universal Enclosures The specialist in sealed equipment What is the mission of Schneider Electric Universal
More informationThree-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41
Data sheet Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 The three-phase monitoring relays CM-PSS.x1 monitor the phase parameters phase sequence, phase failure as well as over- and undervoltage.
More information80 Series - Modular timers 16 A. Features 80.01 80.11
80 Series - Modular timers 16 A Features 80.11 Multi-function and mono-function timer range - Multi-function & multi-voltage 80.11 - On-delay, multi-voltage 17.5 mm wide Six time scales from 0.1s to 24h
More informationTM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector
Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus
More informationT 3000. Substation Maintenance and Commissioning Test Equipment
T 3000 Substation Maintenance and Commissioning Test Equipment Multi function system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy
More informationMasterINTERFACE 39 Series - Relay interface modules
MasterINTERFACE 39 Series - 39 Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy ejection by plastic
More informationCompactLogix Power Supplies Specifications
Technical Data CompactLogix Power Supplies Specifications 1768 CompactLogix Power Supplies Catalog Numbers 1768-PA3, 1768-PB3 1769 Compact I/O Power Supplies Catalog Numbers 1769-PA2, 1769-PB2, 1769-PA4,
More informationLow voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.
Low voltage Direct Current Network Compact NSX DC PV Circuit breakers and switch disconnectors for solar application Catalogue 2012 Compact NSX DC PV A complete DC offer for solar application from 80
More information