Fire/Alarm/Security/Communications Product Catalog

Size: px
Start display at page:

Download "Fire/Alarm/Security/Communications Product Catalog"

Transcription

1 Surge Protection For Business-Critical Continuity TM Fire/Alarm/Security/Communications Product Catalog FPO

2 Protection Against Damage, Disruption, and Costly Downtime of your Mission-Critical Equipment Today s advanced commercial/residential fire, alarm, security and telecommunication systems are more sophisticated than ever before. In a nanosecond, transients can disrupt, disable and ruin your mission-critical equipment. It s why companies turn to Emerson Network Power Surge Protection for their line of surge suppression and filtering products to protect sensitive equipment from excessive maintenance costs, damage and costly downtime. Emerson Network Power s comprehensive portfolio includes products for Data/Signal Line Protection, AC Power Surge Protection, and Filtering/Line Conditioning. Plus, all of our engineered power-quality solutions are backed by a dedicated team of power-quality specialists who are available to share their applications and integration knowledge with you. We re here to help! Why take chances by putting the security of your mission-critical equipment at risk? Turn to Emerson Network Power Surge Protection products for peace of mind. To learn more about the world s most trusted lineup of multi stage, hybrid, solid state, power quality products, call us toll-free at , or visit our Web site at

3 Table of Contents Application Product Page # CCTV Systems Application Drawing 2 Zone/Loop/Data Edco PC642 Series VAC Heavy Duty 120 Volt AC Edco HSP Series 4 Plug-in Surge Protection/Active Tracking Filter Islatrol SP-6TVN 5 CCTV & Data Applications/Coax Edco CX Series 6 Closed Circuit TV Protection Edco CCTV-1 7 One- and Two-Pair Signal Line Protection Edco FAS-1 and FAS-2 Series 7 Two-Pair Signaling Circuit Protector (Modular) Edco PHC Series 8 CAT6/CAT5 Power Over Ethernet Edco CAT6-5POE Series 9 Channel Rackmount Edco RM-CX06-16R 9 Fire Alarm Application Drawing 10 Zone/Loop/Data Edco PC642 Series 11 Two-Pair SLC Loop Protector (Modular) Edco SLCP Series 12 Two-Line Telephone Protection (Modular) Edco PC2-TEL 12 Two-Pair Signaling Circuit Protector (Modular) Edco PHC Series VAC Heavy Duty 120 Volt AC Edco HSP Series /240 VAC Heavy Duty (Parallel) PowerSure EMC-240B 15 One- and Two-Pair Signal Line Protection Edco FAS-1 and FAS-2 Series 16 Medium Duty 120 VAC Single Phase PowerSure FAS-120AC 17 Burglar 12VDC Application Drawings 18 One- and Two-Pair Signal Line Protection Edco FAS-1 and FAS-2 Series 19 Plug-in Surge Protection (Active Tracking Filter) Islatrol SP-6TVN 20 RJ11/RJ31X Telephone Protection Edco FAS-TEL and FAS-31XT 21 Single-Pair Medium Duty Low Voltage Zone/Horn/Strobe/Data Edco TER Series 22 Two-Line Telephone Protection (Modular) Edco PC2-TEL 22 ACCESS CONTROL Application Drawing 23 Electric Door Suppressor Edco EL-EDS 24 Two-Pair Data/Signal Line Power Edco 5W RJ11/RJ31X Telephone Protection Edco FAS-TEL and FAS-31XT VAC Heavy Duty 120 Volt AC Edco HSP Series 27 Zone/Loop/Data Edco PC642 Series 28 Data Circuit Protection Edco LCDP 29 COMMUNICATIONS One- and Two-Pair Signal Line Protection Edco FAS-1 and FAS-2 Series 30 DIN Rail Protection Edco DRS (DC) Series 31 High Frequency Coax Protector N-Type Edco CX-HFN 32 High Frequency Coax Protector F-Type Edco CATV-DF 32 Intercom/Speaker Punch Block Protection (Parallel) Edco OPX Series 33 Intercom/Speaker Punch Block Protection (Series) Edco PB Series 34 Telecom/Punch Block Protection Edco H Series 35 Data/Signal Line/Punch Block Protection Edco COHP Series 36 Fits Standard 66MI-50 Punch Down Blocks Edco MGB Ground Rail 36 RJ11/RJ31X Telephone Protection Edco FAS-TEL and FAS-31XT 37 Multi-Channel Rackmount Edco RM-CAT6-POE Series 38 Data Circuit Protection Edco LCDP 38 RJ-45 Telephone/Data Edco RJA-RJD Series 39 Terminating Assembly Edco TBLK Assembly 40 CAT6/CAT5 Power Over Ethernet Edco CAT6-5POE Series 40 Key Systems Edco Mod-12 41

4 CCTV Systems Protecting CCTV Systems Application Drawing Video Head-End SP 3 SP 5 Video Power SP 4 SP 5 Exterior Fixed Camera Equipment Rack Multiplexer SP 3 SP 5 SP 6 SP 7 Video Power RS-485, RS-422 (PTZ) Power Over Ethernet (POE) SP 4 SP 5 SP 6 SP 7 Exterior Camera with PTZ AC Power SP 1 or SP 2 Exterior POE Camera For POE with PTZ contact Edco Legend SP 1... HSP121BT-1RU SP 2... SP-6TVN SP 3... CX06-M or... RM-CX06-16R (16 ch.) SP 4... CX06-MI SP 5... FAS-1-043HC (2.5A) or... PHC-043* (5A) SP 6... PC642C-008LC* SP 7... CAT6-5 POE-FF or -MF *Needs PCB1B Base 2

5 CCTV Systems Edco PC642 Series Zone/Loop/Data The Edco PC642 Series surge suppressor is a two-pair (four-wire) module implementing three-stage hybrid technology. This module addresses over-voltage transients with gas tubes and silicon avalanche components. In addition, sneak and fault currents are mitigated with resettable fuses (PTCs). The PTCs increase resistance by several orders of magnitude when over-currents exceed safe levels. A normal state resumes when over-currents are removed. The ability to self-restore in this manner significantly increases suppressor performance and survivability. EDCO PCB1B BASE SOLD SEPARATELY OPTION: DIN RAIL KIT AVAILABLE ORDER PART # 11604KIT-PC The Edco PC642 Series card edge module is gold plated, double sided, and is designed to mate with the Edco PCB1B gold-plated female terminal connector. When snapped together, the data circuits pass thru the protector in a serial fashion from the four Field Side terminals to the four Electronics Side terminals. Terminals 1 or 10 of the Edco PCB1B must be attached to Building- Approved Ground per Edco Technical Bulletin # Three-stage hybrid protection Sneak/fault current protection Resettable fusing PTCs Low capacitance option Plug-in module Fast response time Requires Edco PCB1B base Order PC642PTU an invaluable troubleshooting tool 5, 12, 18, 24, 30, 36, 43, 52, 180 VDC 8, 15, 20, 30, 36, 43, 50, 60, 200* VDC Operating Current 0.15A 10 ka (8 x 20 µs) 0 to 20 MHz < 0.1 db at 20 MHz GDT, SAD, w/series PTC Terminal Block w/compression Lugs Terminals Accept Up To 10 AWG Dimensions (Inches) 2H x 1W x 2.5L (PC642 + PCB1B Base) Certification 1 oz UL 497B * PC642C-200 is not UL certified Caution: The hybrid design of this product includes series resistance. Do not place this product in service on any signal line capable of continuously supplying more than 150 milliamperes. Terminal Assignments Unprotected Pair 2 Field Side Unprotected Pair 1 Odd Terminals { { PCB1B: 1.0 Even Terminals } Protected Pair 2 Electronics Side 2.125" 2.4" 2 } Protected Pair 1 Keying Pin Ground Terminal 1 Or 10 To Building-Approved Ground DO NOT daisy chain grounds. NOT intended for shield termination. Install ground in accordance with all applicable codes. PC642 PCB1B APPLICATION: RS485, RS422: PC642C-008LC & PCB1B RS423, Token Ring: PC642C-008LC & PCB1B RS232: E-Net, 10 Base T: PC642C-020 & PCB1B PC642C-030LC & PCB1B 4 20 ma: PC642C-036 & PCB1B How To Specify The Appropriate Model PC642C - Voltage Clamp 8 Volts Volts Volts Volts Volts Volts Volts Volts **200 Volts **Not UL Listed no suffix stage 2 clamp each line-to-ground stage 2 clamp D line-to-line only stage 2 clamp line-to-line X and each line to ground low capacitance option stage LC 2 clamp line-to-line and each line to ground 3

6 CCTV Systems edco hsp121bt-1ru Edco HSP Series 120 VAC Heavy Duty 120 Volt AC The Edco HSP Series is an advanced three-stage hybrid, solid state powerline protector. such as noise filtering, common mode and normal mode suppression, nanosecond reaction time, power line tracking, and compression screw terminations make the Edco HSP Series an excellent choice in commercial and industrial applications. The Edco HSP Series offers a replaceable fuse designed to remove the load (protected equipment) from the line if the unit is either overloaded or the internal protection fails. This feature prevents surges from entering equipment through a failed protector not noticed by the user. edco hsp121a Fast response time Failure indicator Power line tracking Filtering Polycarbonite NEMA 4X enclosure (HSP121A) Three-stage hybrid design Replaceable fuse 1/2" or 3/4" knockouts for nipple conduit connectors (HSP121A) Dimensions Operating Current I-Nominal (In) Total Operating Frequency EMI Attenuation (100 khz to 100 MHz) Modes Of Protection Status Indication 120 VAC 325 VAC 15A 3 ka 39 ka (8 x 20 µs) Hz > 40 db Metal Oxide Varistors (MOVs) w/ L-C Filter Line-to-Neutral, Line-to-Ground, Neutral-to-Ground Power On & MOVs functional 3 Position, 20A Terminal Block w/compression Screws Terminals Accept Up To 14 AWG Dimensions (Inches) HSP121BT-1RU 1.8H x 2.9W x 5.3L HSP-121A 2.95H x 4.95W x 3L 10 oz Certifications HSP121BT-1RU ANSI/UL1449 Third Edition, Type 4 HSP121A ANSI/UL1449 Third Edition, Type 2 Mounting HSP121BT-1RU Holes 3/16" Dia. Light On Normal Light Off Requires Service Mounting HSP121A Holes 3/16" Dia. 3/4" Conduit Fitting 3/4" Conduit Fitting GND 1/2" Conduit Fitting N N 1/2" Conduit Fitting AC GND AC 4

7 CCTV Systems Islatrol SP-6TVN Plug-in Surge Protection/Active Tracking Filter The Islatrol SP-6TVN is an industrial-strength surge suppression/filtering device that plugs into a standard duplex receptacle. It features uniquely designed repositionable outlets and protects against damaging power disturbances traveling through your wiring into your electrical outlets. REPOSITIONABLE OUTLETS Plugs into standard 120V, 15A electrical outlet Total peak surge current capacity of 39 ka Cables for telephone, video, and data connectors included Repositionable outlets rotate to accommodate available space Perfect for tight spaces, behind furniture and appliances Intelligent monitoring against improper wiring/grounding 60 db maximum high frequency Operational indicator lamp AC Power Protection Nominal Operating Voltage 120 VAC, Single Phase Operating Voltage Range 120 VAC +/- 10% Operating Hz Rated Output 15A ANSI/IEEE C62.41 Category Category A & B (6) 5-15R Receptacles and 5-15P Plug Phase Configuration 2 Wire + Gnd Size 7.5 x 4.75 x 1.75 (Inches) Enclosure High Impact Plastic 2.0 lbs (0.9 kgs) Modes Of Protection L N, L G, N G Indication of Suppression Status Status Indicator Response Time <.5 ns Normal Mode Certification ANSI/UL 1449 Third Edition Type 3 Warranty 5 Year Maximum Continuous Operating Voltage (MCOV) Line To Neutral (8 x 20 ms) Line To Neutral Line To Ground Neutral To Ground Total 130 VAC 13 ka 13 ka 13 ka 39 ka ANSI/IEEE C62.41 Cat A Ringwave (6 kv, 200A, 100 khz) Normal Mode Common Mode ANSI/IEEE C62.41 Cat B Ringwave (6 kv, 500A, 100 khz) Normal Mode Common Mode Frequency Response Normal Mode Common Mode Low Voltage Protection 265V 290V 275V 290V 60 db Maximum, Forward/Reverse, 100 khz to 50 MHz 40 db Maximum, Forward/Reverse, 5 MHz to 50 MHz Video 1 & 2 Phone Network Type F Type RJ-11 Type RJ-45 Cables Provided 6 (2x) Type F RJ-11 Male RJ-45 Male 6' Ends 6' Ends Ends 5 ka 2 ka 3 ka (8 x 20 µs) (10 x 1000 µs) (8 x 20 µs) Capacitance <12 pf <50 pf <70 pf Protection Level L-G T-R, T-G, R-G L-G (8 Lines) (DC) 145 V V 30 V Attenuation 1 2 Ghz N/A N/A 5

8 CCTV Systems Edco CX Series CCTV & Data Applications/Coax OPTION: DIN RAIL KIT AVAILABLE ORDER PART # 11604KIT-CX The Edco CX Series Surge Protective Devices (SPDs) implement three-stage hybrid technology. The SPDs address over-voltage transients with a primary Gas Discharge Tube (GDT), and secondary Silicon Avalanche Diode (SAD) components. Over-current protection, e.g. sneak and fault currents, are mitigated with solid-state resettable fuses PTCs. The Edco CX Series SPDs are designed in accordance with NFPA 780 (2004 edition) requirements, with up to 20 ka of surge current capability. The Edco CX06-MI model has an isolated ground and is recommended for use at the camera end. Sneak/fault current protection Low insertion loss Shielded case CX06-MI has an isolated ground 5 VDC 6 VDC Operating Current 0.17A 20 ka (8 x 20 µs) 0 to 20 MHz < 1 db at 20 MHz GDT, SAD, w/series PTC BNC, 50/75 Ohms Dimensions (Inches) M = 1.5H x 1W x 3.25L MI = 1.5H x 1W x 4L SBL = 1.7H x 1.4W x 2.8L M = 2.3 oz MI = 3 oz Certification UL 497B CX06-MI-SBL Installation Head End Camera End CX06-M CX06-MI CX06-MI-SBL Other configurations available please consult factory 6

9 CCTV Systems Edco CCTV-1 Closed Circuit TV Protection The Edco CCTV-1 application is specifically designed for lightning protection on closed circuit TV systems. The protector is easily installed with standard type BNC coax connectors. The Edco CCTV-1 offers low loss, even at frequencies approaching 500 Mhz. This is important for error-free data communication applications. Automatic recovery Shielded case Low insertion loss Miniature size Easily installed 5 VDC 90 VDC (Spark Over Voltage) Operating Current 1A 10 ka (8 x 20 µs) 0 to 1 GHz < 0.5 db at 500 MHz <1.0 db at 900 MHz Gas Discharge Tube (GDT) BNC, 75 Ohm Dimensions (Inches) 0.6H x 0.6W x 2.0L 1 oz Edco FAS-1 and FAS-2 Series One- and Two-Pair Signal Line Protection The Edco FAS-1 and Edco FAS-2 Series are multi-stage one-pair or two-pair surge suppressors designed for high-exposure applications. These products were specifically designed to meet multiple, low voltage, protection applications in the fire and security industries. Lightning protection for low voltage Data/signal lines Multi stage protection Common mode and differential protection mode Automatic recovery 15, 24, 36, 52 VDC 18, 33, 43, 60 VDC Operating Current 2.5A 10 ka (8 x 20 µs) 0 to 10 MHz < 0.1 db at 10 MHz GDT, SAD, w/series Inductor Terminal Block w/compression Lugs Terminals Accept Up To 12 AWG Dimensions (Inches) FAS-1 = 1.5H x 1.5W x 2.8L FAS-2 = 2H x 2W x 2.8L FAS-1 = 3.5 oz FAS-2 = 7 oz Certification UL 497B Installation Unprotected Or Field Side Ground Lug AWG Equip. Line Protected Equipment DO NOT daisy chain grounds. NOT intended for shield termination. Install ground in accordance with all applicable codes. FAS HC (One-pair) FAS HC (Two-pair) FAS HC (One-pair) FAS HC (Two-pair) FAS HC (One-pair) FAS HC (Two-pair) FAS HC (One-pair)* FAS HC (Two-pair)* *Not UL listed 12 VDC Use 24 VDC Use 24 VAC Use 48V Systems Use Caution: The hybrid design of this product includes series resistance. Do not place this product in service on any signal line capable of continuously supplying more than 2.5 amperes. 7

10 CCTV Systems Edco PHC Series Two-Pair Signaling Circuit Protector (Modular) The Edco PHC Series is designed to protect two pairs of wires specifically for alarm and security systems where operating currents can be as high as 5 amps. Electrically, the Edco PHC Series is a rugged series hybrid implementing a staged complement of MOVs, copper wound inductors and Silicon Avalanche Diodes. This design reduces series resistance to 0.2 Ohms per pair. These products are intended to mate with an Edco PCB1B gold-plated female terminal connector. EDCO PCB1B BASE SOLD SEPARATELY EDCO PCB1B BASE SOLD SEPARATELY The Edco PHC modules plug into a base assembly (Edco PCB1B). The base assembly can be mounted to any flat surface and should be located as close as practical to the protected equipment. Terminal 1 and/or terminal 10 should be connected to Building-Approved Ground with 12- or 10-gauge solid wire. Three-stage protection Differential protection Common mode protection Plug-in module Automatic recovery Fast response time Continuous current up to 5 Amps UL 497B listed Requires Edco PCB1B base Order PC642PTU an invaluable troubleshooting tool 12, 18, 24, 36, 52, 70, 120 VDC Operating Current 15, 20, 30, 43, 60, 100, 150 VDC 5A 10 ka (8 x 20 µs) 0 to 10 MHz < 0.1 db at 10 MHz MOV, SAD, w/series Inductor Terminal Block w/compression Lugs Terminals Accept Up To 10 AWG Dimensions (Inches) 3.7H x 1.75W x 2.375L (PHC + PCB1B Base) Certification 8 oz UL 497B Terminal Assignments Unprotected Pair 2 Field Side Unprotected Pair 1 Odd Terminals { { PCB1B: 1.0 Even Terminals } Protected Pair 2 Electronics Side 2.125" 2.4" 2 } Protected Pair 1 Keying Pin Ground Terminal 1 Or 10 To Building-Approved Ground DO NOT daisy chain grounds. NOT intended for shield termination. Install ground in accordance with all applicable codes. Dimensions How To Specify The Appropriate Model Voltage Clamp * Not UL listed Applications Part Number 24V Horn, Strobe, Bell 70V Speaker Lines PHC-043 & PCB1B PHC-SP70 & PCB1B 8

11 CCTV Systems Edco CAT6-5POE Series CAT6/CAT5 Power Over Ethernet The Edco CAT6-5POE Series is designed to work on Category 5 Power-Over- Ethernet transmission lines as well as Category 6 applications. Ideal to protect expensive equipment against surges and transients entering a building on exposed transmission lines. Available in both female to female and male to female RJ-45 connectors. Exceeds CAT5 & 6 transmission values CAT5 POE compatible CAT6 compatible Applications up to ma 1 year warranty 60 VDC RJ-45 Jacks RJ-45 (Female-Female) CAT6-5POE-FF 65 VDC RJ-45 (Male-Female) CAT6-5POE-MF Operating Current 300 ma 60A (10 x 1000 µs) 0 to 250 MHz Dimensions (Inches) 0.8H x 1.0W x 2.3L (FF). 0.8H x 1.0W x 3.0L (MF) 1 oz < 0.1 db at 20 MHz Silicon Avalanche Diode (SAD) Edco RM-CX06-16R Channel Rackmount The Edco RM-CX06-16R Surge Protective Device (SPD) is a 16 channel coax SPD implementing three-stage hybrid technology. The SPD addresses over-voltage transients with a primary Gas Discharge Tube (GDT), and secondary Silicon Avalanche Diode (SAD) components. Over-current protection, e.g., sneak and fault currents, are mitigated with new solid-state resettable fuses PTCs. The Edco RM-CX06-16R SPD is designed in accordance with NFPA 780 (2004 edition) requirements, with up to 20 ka of surge current capability. Sneak/fault current protection Low insertion loss Shielded case 16 channel 1 year warranty 5 VDC 0 to 100 MHz 6 VDC < 0.1 db at 20 MHz Dimensions (Inches) 1.75H x 19W x 2.0D (1U) Operating Current 0.15A GDT, SAD, w/series PTC 3.2 lbs 20 ka (8 x 20 µs) BNC, 50/75 Ohm Certification UL 497B 9

12 Fire Alarm Protecting Fire Alarm Systems Application Drawing SP 4 SLC Loop Penetrating Exterior SP 4 Fire Alarm Panel (24 VDC Typical) SP 5 SP 6 SP 7 RS-485 Network Exterior Post Indicator Valve Circuit Exterior (Over 1000 feet need protection at wall penetration point) Notification Appliance Circuit Exterior SP 6 SP 5 SP 7 SP 8 Printer Circuit To Guard House (RS-232 Typical) SP 8 AC Power SP 1 or SP 2 or SP 9 Telephone Line SP 3 SP 1... FAS-120AC SP 2... HSP-121BT1RU SP 3... PC2-TEL* SP 4... SLCP-43* SP 5... PC642C-008LC* Legend SP 6... FAS-1-033HC SP 7... PHC-043* SP 8... PC642C-020* SP 9... EMC-240B *Needs PCB1B Base 10

13 Fire Alarm Edco PC642 Series Zone/Loop/Data The Edco PC642 Series surge suppressor is a two-pair (four-wire) module implementing three-stage hybrid technology. This module addresses over-voltage transients with gas tubes and silicon avalanche components. In addition, sneak and fault currents are mitigated with resettable fuses (PTCs). The PTCs increase resistance by several orders of magnitude when over-currents exceed safe levels. A normal state resumes when over-currents are removed. The ability to self-restore in this manner significantly increases suppressor performance and survivability. EDCO PCB1B BASE SOLD SEPARATELY OPTION DIN RAIL KIT AVAILABLE ORDER PART # 11604KIT-PC The Edco PC642 card edge module is gold plated, double sided, and is designed to mate with the Edco PCB1B gold-plated female terminal connector. When snapped together, the data circuits pass thru the protector in a serial fashion from the four Field Side terminals to the four Electronics Side terminals. Terminals 1 or 10 of the Edco PCB1B must be attached to Building-Approved Ground per Edco Technical Bulletin # Three-stage hybrid protection Sneak/fault current protection Resettable fusing PTCs Low capacitance option Plug-in module Fast response time Requires Edco PCB1B base Order PC642PTU an invaluable troubleshooting tool 5, 12, 18, 24, 30, 36, 43, 52, 180 VDC 8, 15, 20, 30, 36, 43, 50, 60, 200* VDC Operating Current 0.15A 10 ka (8 x 20 µs) 0 to 20 MHz < 0.1 db at 20 MHz GDT, SAD, w/series PTC Terminal Block w/compression Lugs Terminals Accept Up To 10 AWG Dimensions (Inches) 2H x 1W x 2.5L (PC642 + PCB1B Base) Certification 1 oz UL 497B * PC642C-200 is not UL certified Caution: The hybrid design of this product includes series resistance. Do not place this product in service on any signal line capable of continuously supplying more than 150 milliamperes. Terminal Assignments Ground Terminal 1 Or 10 To Building-Approved Ground DO NOT daisy chain grounds. NOT intended for shield termination. Install ground in accordance with all applicable codes. APPLICATION: RS485, RS422: PC642C-008LC & PCB1B RS423, Token Ring: PC642C-008LC & PCB1B RS232: E-Net, 10 Base T: PC642C-020 & PCB1B PC642C-030LC & PCB1B 4 20 ma: PC642C-036 & PCB1B How To Specify The Appropriate Model Voltage Clamp **200 Volts **Not UL Listed 11

14 Fire Alarm Edco SLCP Series Two-Pair SLC Loop Protector (Modular) The Edco SLCP Series are four-wire modules designed to protect signaling line circuits (SLC). The device has 0 ohms of resistance and offers line-toground protection. EDCO PCB1B BASE SOLD SEPARATELY Compatible with SLC circuits Line-to-ground protection State-of-the-art silicon technology Over-current protection 497B UL listed Requires Edco PCB1B base PC642PTU (Pass Thru Unit) available for troubleshooting 5, 12, 18, 24, 32, 36, 48, & 52 VDC 8, 15, 20, 30, 36, 43, 50, & 60 VDC Operating Current 1A 250A (8 x 20 µs) 0 to 20 MHz < 0.1 db at 20 MHz Silicon Avalanche Diode (SAD) Terminal Block w/compression Lugs Terminals Accept Up To 10 AWG Dimensions (Inches) 2H x 1W x 2.5L (SLCP + PCB1B Base) Certification 1 oz UL 497B S L C P Clamping Voltage 8 Volts 15 Volts 20 Volts 30 Volts 36 Volts 43 Volts 50 Volts 60 Volts Edco PC2-TEL Two-Line Telephone Protection (Modular) The Edco PC2-TEL is a solid state, two-line telephone interface protector module. This unit is specifically designed to protect both phone lines required by commercial fire panels. EDCO PCB1B BASE SOLD SEPARATELY Tip-to-ring protection Tip- and ring-to-ground protection Over-current protection Resettable solid state fuses PTC UL listed 497A Requires PCB1B base PC642PTU (Pass Thru Unit) available for trouble shooting 250 VDC 270 VDC Operating Current 0.15A 160A (10 x 1000 T & R To Ground) 0 to 20 MHz < 0.1 db at 20 MHz Series PTC and Silicon Avalanche Diode (SAD) Terminal Block w/compression Lugs Terminals Accept Up To 10 AWG Dimensions (Inches) 2H x 1W x 2.5L (PC2TEL + PCB1B Base) Certifications 1 oz UL 497A, CUL 12

15 Fire Alarm Edco PHC Series Two-Pair Signaling Circuit Protector (Modular) The Edco PHC Series is designed to protect two pairs of wires specifically for alarm and security systems where operating currents can be as high as 5 amps. Electrically, the Edco PHC Series is a rugged series hybrid implementing a staged complement of MOVs, copper wound inductors and Silicon Avalanche Diodes. This design reduces series resistance to 0.2 Ohms per pair. These products are intended to mate with an Edco PCB1B gold-plated female terminal connector. EDCO PCB1B BASE SOLD SEPARATELY The Edco PHC modules plug into a base assembly (Edco PCB1B). The base assembly can be mounted to any flat surface and should be located as close as practical to the protected equipment. Terminal 1 and/or terminal 10 should be connected to Building-Approved Ground with 12- or 10-gauge solid wire. Three-stage protection Differential protection Common mode protection Plug-in module Automatic recovery Fast response time Continuous current up to 5 Amps UL 497B listed Requires Edco PCB1B base Order PC642PTU an invaluable troubleshooting tool 12, 18, 24, 36, 52, 70, 120 VDC Operating Current 15, 20, 30, 43, 60, 100, 150 VDC 5A 10 ka (8 x 20 µs) 0 to 10 MHz < 0.1 db at 10 MHz MOV, SAD, w/series Inductor Terminal Block w/compression Lugs Terminals Accept Up To 10 AWG Dimensions (Inches) 3.7H x 1.75W x 2.375L (PHC + PCB1B Base) Certification Applications Part Number 8 oz UL 497B Terminal Assignments Unprotected Pair 2 Field Side Unprotected Pair 1 Odd Terminals { { PCB1B: 1.0 Even Terminals } Protected Pair 2 Electronics Side 2.125" 2.4" 2 } Protected Pair 1 Keying Pin Ground Terminal 1 Or 10 To Building-Approved Ground DO NOT daisy chain grounds. NOT intended for shield termination. Install ground in accordance with all applicable codes. Dimensions How To Specify The Appropriate Model Voltage Clamp P H C Volts Volts Volts Volts Volts (For Horn, Bell, Strobes) S P 7 0 *100 Volts R M S *150 Volts (For 120V Signal Lines) *Not UL Listed 24V Horn, Strobe, Bell 70V Speaker Lines PHC-043 & PCB1B PHC-SP70 & PCB1B 13

16 Fire Alarm edco hsp121bt-1ru Edco HSP Series 120 VAC Heavy Duty 120 Volt AC The Edco HSP Series is an advanced three-stage hybrid, solid state power- line protector. such as noise filtering, common mode and normal mode suppression, nanosecond reaction time, power line tracking, and compression screw terminations make the Edco HSP Series an excellent choice in commercial and industrial applications. The Edco HSP Series offers a replaceable fuse designed to remove the load (protected equipment) from the line if the unit is either overloaded or the internal protection fails. This feature prevents surges from entering equipment through a failed protector not noticed by the user. edco hsp121a Fast response time Failure indicator Power line tracking Filtering Polycarbonite NEMA 4X enclosure (HSP121A) Three-stage hybrid design Replaceable fuse 1/2" or 3/4" knockouts for nipple conduit connectors (HSP121A) Dimensions Operating Current I-Nominal (In) Total Operating Frequency EMI Attenuation (100 khz to 100 MHz) Modes Of Protection Status Indication 120 VAC 325 VAC 15A 3 ka 39 ka (8 x 20 µs) Hz > 40 db Metal Oxide Varistors (MOVs) w/ L-C Filter Line-to-Neutral, Line-to-Ground, Neutral-to-Ground Power On & MOVs functional 3 Position, 20A Terminal Block w/compression Screws Terminals Accept Up To 14 AWG Dimensions (Inches) HSP121BT-1RU 1.8H x 2.9W x 5.3L HSP-121A 2.95H x 4.95W x 3L 10 oz Certifications HSP121BT-1RU ANSI/UL1449 Third Edition, Type 4 HSP121A ANSI/UL1449 Third Edition, Type 2 Mounting HSP121BT-1RU Holes 3/16" Dia. Light On Normal Light Off Requires Service Mounting HSP121A Holes 3/16" Dia. 3/4" Conduit Fitting 3/4" Conduit Fitting GND 1/2" Conduit Fitting N N 1/2" Conduit Fitting AC GND AC 14

17 Fire Alarm PowerSure EMC-240B 120/240 VAC Heavy Duty (Parallel) The PowerSure EMC-240B surge suppressor is designed to protect AC distribution panel circuits or 120V power supplies feeding sensitive electronic equipment. Electrically, the unit incorporates MOV and thermal fusing technology. The PowerSure EMC-240B is designed to be installed in parallel on standard single phase 120/240 VAC (3W + G) or single phase 120 VAC (2W + G) circuits. Fast response time 40 ka per phase capacity Failsafe and fused Operational status indicators ANSI/UL 1449 Third Edition Type 2 120/240 VAC I Nominal (In) 3 ka Operating Current NA, Parallel Total 80 ka (8 x 20 µs) Operating Frequency Hz EMI Attenuation (100 khz to 100 MHz) > 40 db Metal Oxide Varistors (MOVs) Modes Of Protection Line-to-Line Line-to-Neutral Status Indication Power On & MOVs Functional Wire Leads Dimensions (Inches) 4.6H x 2.2W x 2.8L 13.5 oz Certification ANSI/UL 1449 Third Edition, Type 2 Mechanical 4.5" 2.8" 2.2" 18" Caution: Installation and service should be performed by qualified electricians only. Before installing EMC, remove all electrical power from circuits. Connect on load side of main breakers. Use two dedicated 30A circuit breakers. Installation 120 VAC Service 120/240 VAC Service 240 V AC Service L N 120 V EMC-240B L1 240 V L2 N 120 V 120 V EMC-240B L1 240 V L2 GND 240 V 240 V EMC-240B Ground N L Black Black White Green Ground L2 N L1 Black Black White Green L2 GND L1 Black Black White Green

18 Fire Alarm Edco FAS-1 and FAS-2 Series One- and Two-Pair Signal Line Protection The Edco FAS-1 and Edco FAS-2 Series are multi stage one-pair or two-pair surge suppressors designed for high exposure applications. These products were specifically designed to meet multiple low voltage protection applications in the fire and security industries. Lightning protection for low voltage Data/signal lines Multi stage protection Common mode and differential protection mode Automatic recovery 15, 24, 36, 52 VDC 18, 33, 43, 60 VDC Operating Current 2.5A 10 ka (8 x 20 µs) 0 to 10 MHz < 0.1 db at 10 MHz GDT, SAD, w/series Inductor Terminal Block w/compression Lugs Terminals Accept Up To 12 AWG Dimensions (Inches) FAS-1 = 1.5H x 1.5W x 2.8L FAS-2 = 2H x 2W x 2.8L FAS-1 = 3.5 oz FAS-2 = 7 oz Certification UL 497B Installation Unprotected Or Field Side Ground Lug AWG Equip. Line < 3 Protected Equipment FAS HC (One-pair) FAS HC (Two-pair) FAS HC (One-pair) FAS HC (Two-pair) FAS HC (One-pair) FAS HC (Two-pair) FAS HC (One-pair)* FAS HC (Two-pair)* * Not UL listed 12VDC Use 24VDC Use 24VAC Use 48V Systems Use Caution: The hybrid design of this product includes series resistance. Do not place this product in service on any signal line capable of continuously supplying more than 2.5 amperes. DO NOT daisy chain grounds. NOT intended for shield termination. Install ground in accordance with all applicable codes. 16

19 Fire Alarm PowerSure FAS-120AC Medium Duty 120 VAC Single Phase The PowerSure FAS-120AC surge suppressor is designed to protect AC distribution panel circuits or 120V power supplies feeding sensitive electronic equipment. Electrically the unit incorporates MOV and thermal fusing technology. This device is designed to be installed in parallel on standard single phase 120 VAC (L, N, G) circuits. Installation can be close-nipple up to a distribution panel/circuit or hardwired in parallel up to power supply input terminal screws. Be sure to dress leads as short as possible. LED indicator Fast response time Thermal fuse L-G, L-N, & N-G protection Compact size Liquid tight conduit fitting ANSI/UL 1449 Third Edition Type 2 Mounting Part Number PowerSure FAS-120AC 120 VAC SPD Location Type Type 2 I-Nominal (In) 3 ka Operating Current NA 6.5 ka/mode, 13 ka/phase, 15.5 ka/total Operating Frequency Hz EMI Attenuation NA MOVs Modes of Protection L-N, L-G, N-G Status Indication Power On & MOVs Functional Wire Leads Dimensions (Inches) 2.5H x 1.5W x 3.0L 4 oz Certification ANSI/UL 1449 Third Edition, Type 2 2.5" Ø " Caution: This product should be installed and serviced by qualified service technicians or personnel only. Remove power before installation or service. 3" 17

20 Burglar 12VDC Protecting Burglar Alarm Systems Application Drawings Commercial Residential 18

21 Burglar 12VDC Edco FAS-1 and FAS-2 Series One- and Two-Pair Signal Line Protection The Edco FAS-1 and Edco FAS-2 Series are multi stage one-pair or two-pair surge suppressors designed for high-exposure applications. These products were specifically designed to meet multiple, low voltage, protection applications in the fire and security industries. Lightning protection for low voltage Data/signal lines Multi stage protection Common mode and differential protection mode Automatic recovery 15, 24, 36, 52 VDC 18, 33, 43, 60 VDC Operating Current 2.5A 10 ka (8 x 20 µs) 0 to 10 MHz < 0.1 db at 10 MHz GDT, SAD, w/series Inductor Terminal Block w/compression Lugs Terminals Accept Up To 12 AWG Dimensions (Inches) FAS-1 = 1.5H x 1.5W x 2.8L FAS-2 = 2H x 2W x 2.8L FAS-1 = 3.5 oz FAS-2 = 7 oz Certification UL 497B Installation Unprotected Or Field Side Ground Lug AWG < 3 Equip. Line FAS HC (One-pair) FAS HC (Two-pair) FAS HC (One-pair) FAS HC (Two-pair) FAS HC (One-pair) FAS HC (Two-pair) FAS HC (One-pair)* FAS HC (Two-pair)* *Not UL listed 12VDC Use 24VDC Use 24VAC Use 48V Systems Use Caution: The hybrid design of this product includes series resistance. Do not place this product in service on any signal line capable of continuously supplying more than 2.5 amperes. Protected Equipment DO NOT daisy chain grounds. NOT intended for shield termination. Install ground in accordance with all applicable codes. 19

22 Burglar 12VDC Islatrol SP-6TVN Plug-in Surge Protection (Active Tracking Filter) The Islatrol SP-6TVN is an industrial-strength surge suppression/filtering device that plugs into a standard duplex receptacle. It features uniquely designed repositionable outlets and protects against damaging power disturbances traveling through your wiring into your electrical outlets. REPOSITIONABLE OUTLETS Plugs into standard 120V, 15A electrical outlet Total peak surge current capacity of 39 ka Cables for telephone, video, and data connectors included Repositionable outlets rotate to accommodate available space Perfect for tight spaces, behind furniture and appliances Intelligent monitoring against improper wiring/grounding 60 db maximum high frequency Operational indicator lamp AC Power Protection Nominal Operating Voltage 120 VAC, Single Phase Operating Voltage Range 120 VAC +/- 10% Operating Hz Rated Output 15A ANSI/IEEE C62.41 Category Category A & B (6) 5-15R Receptacles and 5-15P Plug Phase Configuration 2 Wire + Gnd Size 7.5 x 4.75 x 1.75 (Inches) Enclosure High Impact Plastic 2.0 lbs (0.9 kgs) Modes Of Protection L N, L G, N G Indication Of Suppression Status Status Indicator Response Time <.5 ns Normal Mode Certification ANSI/UL 1449 Third Edition Type 3 Maximum Continuous Operating Voltage (MCOV) Line To Neutral (8 x 20 ms) Line To Neutral Line To Ground Neutral To Ground Total 130 VAC 13 ka 13 ka 13 ka 39 ka ANSI/IEEE C62.41 Cat A Ringwave (6 kv, 200A, 100 khz) Normal Mode Common Mode ANSI/IEEE C62.41 Cat B Ringwave (6 kv, 500A, 100 khz) Normal Mode Common Mode Frequency Response Normal Mode Common Mode Low Voltage Protection 265V 290V 275V 290V 60 db Maximum, Forward/Reverse, 100 khz to 50 MHz 40 db Maximum, Forward/Reverse, 5 MHz to 50 MHz Video 1 & 2 Phone Network Type F Type RJ-11 Type RJ-45 Cables Provided 6 (2x) Type F RJ-11 Male RJ-45 Male 6' Ends 6' Ends Ends 5 ka 2 ka 3 ka (8 x 20 µs) (10 x 1000 µs) (8 x 20 µs) Capacitance <12 pf <50 pf <70 pf Protection Level L-G T-R, T-G, R-G L-G (8 Lines) (DC) 145 V V 30 V Attenuation 1 2 Ghz N/A N/A 20

23 Burglar 12VDC Edco FAS-TEL and FAS-31XT RJ11/RJ31X Telephone Protection The Edco FAS-TEL and Edco FAS-31XT are single-pair telephone or data line protectors that implement advanced two-stage hybrid design. These units address over-voltage transients with silicon breakover devices, while sneak and fault currents are mitigated with PTC technology which consists of solid state resettable fuses. The Edco FAS-31XT replaces the RJ31X jack with a protected version. Four screw terminals are provided to wire the protector in the same manner as a standard RJ31X jack. The Edco FAS-TEL is nearly identical to the Edco FAS-31XT except with out the shorting bars. Two screw terminals are provided to connect the incoming telephone line to the protector. Protected equipment such as modems are plugged into the female modular jack on the Edco FAS-TEL. <1 nanosecond response time Solid-state silicon breakover technology Low capacitance Over current protection UL 497A listed Line-to-line protection Line-to-ground protection Polyswitch resettable fuses PTCs How To Specify The Appropriate Model 12, 24, 43, 52, 180, 220, & 220 VDC 15, 30, 50, 60, 200, 270 & 300 VDC Operating Current 0.15A Dimensions (Inches) Certifications FAS-TEL-060T FAS-TEL-200T FAS-31XT FAS-TEL-DSL 160A (10 x 1000 µs T & R to Ground) 0 to 20 MHz < 0.1 db at 20 MHz Silicon Avalanche Diode w/ Series PTC Terminal Block w/compression Lugs In/ RJ Connector Out 1H x 2W x 2L 2 oz UL 497A, CUL Digital Phone Analog Phone/Fax/Modem Alarm System Phone DSL F A S - T E L - T F A S X T F A S - T E L - D S L Clamping Voltage 15 Volts 30 Volts 50 Volts 60 Volts 200 Volts 270 Volts 300 Volts 21

24 Burglar 12VDC Edco TER Series Single-Pair Medium Duty Low Voltage Zone/Horn/Strobe/Data The Edco TER surge suppressor directly installs onto electronic circuit wiring terminal screws. This close proximity preserves Edco TER s response time, clamping level and ground reference by elimi nating lead lengths. The Edco TER s miniature size fits directly inside fire or security panels, CCTV housings and other system electronic enclosures. These features maximize surge suppression performance while reducing hardware and labor costs to install. Fits Euro style and barrier strip terminals Automatic recovery Single-pair protection High energy silicon avalanche technology UL 497B listed Operating current > 2 Amps Compact size: 1.3" x 0.4" x 2" (HxWxL) 15, 30, 40 VDC 18, 33, 43 VDC Operating Current 0.09A (10 x 1000 µs) 018 = 215A, 033 = 108A, 043 = 81A 0 to 20 MHz <0.1 db at 20 MHz Silicon Avalanche Diode (SAD) Terminal Block w/compression Lugs Terminals Accept Up To 12 AWG Dimensions (Inches) 1.3H x 0.4W x 2.0L Certification 0.6 oz UL 497B Fits In Series With Circuits Wires At The Terminal Screws Zone, Buss, Loop, Data, Receive, Bell, Horn, Strobe, Pan/Tilt & CCTV TER-018 (For 12 VDC Systems) TER-033 (For 24 VDC Systems) TER-043 (For 24 VDC Systems) Edco PC2-TEL Two-Line Telephone Protection (Modular) EDCO PCB1B BASE SOLD SEPARATELY The Edco PC2-TEL is a solid state, two-line telephone interface protector module. This unit is specifically designed to protect both phone lines required by commercial security panels. Tip-to-ring protection Tip- and ring-to-ground protection Over-current protection Resettable solid state fuses PTCs UL listed 497A Requires PCB1B base PC642PTU (Pass Thru Unit) available for troubleshooting 250 VDC 270 VDC Operating Current 0.15A 160A (10 x 1000 T & R To Ground) 0 to 20 MHz < 0.1 db at 20 MHz Series PTC and Silicon Avalanche Diode (SAD) Terminal Block w/compression Lugs Terminals Accept Up To 10 AWG Dimensions (Inches) 2H x 1W x 2.5L (PC2TEL + PCB1B Base) Certifications 1 oz UL 497A, CUL 22

25 Access Control Protecting Access Control Systems Application Drawing SP 1 Door Lock Power Supply Dial-Up Com SP 8 SP 7 Access Control Panel SP 2 SP 3 SP 4 SP 5 RS-485/RS-422 Circuit Electric Strike or Maglock Circuit Card Reader (Wiegand) SP 3 Circuit for Device Outside of Building To Head-End or Other Control Panels SP 4 SP 2 LAN/ WAN AC Power SP 1 SP 5 SP 6 Gate Position Switch Gate Lock/Control Legend SP 1... HSP-121BT1RU SP 2... PC642C-008LC* SP 3... EL-EDS SP W8-30* SP 5... FAS-1-xxxHC SP 6... FAS-2-xxxHC SP 7... LCDP-xxx SP 8... FAS-31XT *Needs PCB1B Base 23

26 Access Control Edco EL-EDS Electric Door Suppressor The Edco EL-EDS suppressor kit is intended for installation with electrical switching devices that are connected through a relay contact on typical access control panels. The Edco EL-EDS protects against electrical anomalies (transients) that are generated as a result of the collapsing electrical field of an electromagnetic switching device (maglock or electric strike). The Edco EL-EDS provides protection for both relay contacts and control panel. <1 Electromagnetic protection 2 devices per package Relay contact and control panel protection Installation Operating Current Dimensions (Inches) Warranty 52 VDC 56 VDC NA 500 A 0 to 20 MHz <0.1 db at 20 MHz SAD w/filtering Capacitor Wire Leads -40 C C 8 L 1 oz 5 years The diagram below illustrates the proper installation of the Edco EL-EDS. For each maglock or electric strike circuit, you will need to install a suppressor (1) across the relay contacts and (2) across the leads connected to the lock solenoid (locate as close as possible to the solenoid). The suppressor wires can be installed without regard to polarity. If your package does not contain two (2) devices, contact your distributor. 24

27 Access Control Edco 5W8-30 Two-Pair Data/Signal Line Power The Edco 5W8-30 is an access control protection module designed for typical Wiegand outputs for access devices. This is a 5-wire module that accommodates low voltage data lines for 5 VDC circuits. Fifth wire power protection will allow up to 24 VDC. EDCO PCB1B BASE SOLD SEPARATELY In addition, sneak and fault currents are mitigated with resettable fuses (PTCs). The PTCs increase resistance several orders of magnitude when overcurrents exceed safe levels. A normal state resumes when over-currents are removed. The ability to self restore in this manner significantly increases suppressor performance and survivability. Automatic recovery Fast response time Resettable fusing PTCs Plug-in module Data and power protection combined Sneak/fault current protection (data only) Silicon avalanche technology Requires Edco PCB1B base PC462 PTU (Pass Thru Unit) available for troubleshooting Note: The hybrid design of this product includes series resistance. Do not use this device if data pairs are capable of continuously supplying more than 150 milliamperes. 5 VDC (Data) & 24 VDC (Power) 8 VDC (Data) & 30 VDC (Power) Operating Current 0.15A Data = 125A (10 x 1000 µs) Power = 500 A (8 x 20 µs) 0 to 20 MHz < 0.15dB at 20 MHz MOV, SAD, w/ Series PTC Terminal Block w/compression Lugs Terminals Accept Up To 10 AWG Dimensions (Inches) 2H x 1W x 2.5L (5W PCB1B Base) 1 oz Installation DC Power T-Tap Positive Common Wire Here Ground Terminal To Building-Approved Ground (Preferably AC Power Safety Ground) DO NOT daisy chain grounds. NOT intended for shield termination. Install ground in accordance with all applicable codes. 25

28 Access Control Edco FAS-TEL and FAS-31XT RJ11/RJ31X Telephone Protection The Edco FAS-TEL and Edco FAS-31XT are single-pair telephone or data line protectors that implement advanced two-stage hybrid design. These units address over-voltage transients with silicon breakover devices, while sneak and fault currents are mitigated with PTC technology which consists of solid state resettable fuses. The Edco FAS-31XT replaces the RJ31X jack with a protected version. Four screw terminals are provided to wire the protector in the same manner as a standard RJ31X jack. The Edco FAS-TEL is nearly identical to the Edco FAS-31XT except with out the shorting bars. Two screw terminals are provided to connect the incoming telephone line to the protector. Protected equipment such as modems are plugged into the female modular jack on the Edco FAS-TEL. <1 nanosecond response time Solid-state silicon breakover technology Low capacitance Over current protection UL 497A listed Line-to-line protection Line-to-ground protection Polyswitch resettable fuses PTCs How To Specify The Appropriate Model 12, 24, 43, 52, 180, 220, & 220 VDC 15, 30, 50, 60, 200, 270 & 300 VDC Operating Current 0.15A Dimensions (Inches) Certifications FAS-TEL-060T FAS-TEL-200T FAS-31XT FAS-TEL-DSL 160A (10 x 1000 µs T & R to Ground) 0 to 20 MHz < 0.1 db at 20 MHz Silicon Avalanche Diode w/ Series PTC Terminal Block w/compression Lugs In/ RJ Connector Out 1H x 2W x 2L 2 oz UL 497A, CUL Digital Phone Analog Phone/Fax/Modem Alarm System Phone DSL F A S - T E L - T F A S X T F A S - T E L - D S L Clamping Voltage 15 Volts 30 Volts 50 Volts 60 Volts 200 Volts 270 Volts 300 Volts 26

29 Access Control edco hsp121bt-1ru Edco HSP Series 120 VAC Heavy Duty 120 Volt AC The Edco HSP Series is an advanced three-stage hybrid, solid state, powerline protector. such as noise filtering, common mode and normal mode suppression, nanosecond reaction time, power line tracking, and compression screw terminations make the Edco HSP Series an excellent choice in commercial and industrial applications. The Edco HSP Series offers a replaceable fuse designed to remove the load (protected equipment) from the line if the unit is either overloaded or the internal protection fails. This feature prevents surges from entering equipment through a failed protector not noticed by the user. edco hsp121a Fast response time Failure indicator Power line tracking Filtering Polycarbonite NEMA 4X enclosure (HSP121A) Three-stage hybrid design Replaceable fuse 1/2" or 3/4" knockouts for nipple conduit connectors (HSP121A) Dimensions Operating Current I-Nominal (In) Total Operating Frequency EMI Attenuation (100 khz to 100 MHz) Modes Of Protection Status Indication 120 VAC 325 VAC 15A 3 ka 39 ka (8 x 20 µs) Hz > 40 db Metal Oxide Varistors (MOVs) w/ L-C Filter Line-to-Neutral, Line-to-Ground, Neutral-to-Ground Power On & MOVs functional 3 Position, 20A Terminal Block w/compression Screws Terminals Accept Up To 14 AWG Dimensions (Inches) HSP121BT-1RU 1.8H x 2.9W x 5.3L HSP-121A 2.95H x 4.95W x 3L 10 oz Certifications HSP121BT-1RU ANSI/UL1449 Third Edition, Type 4 HSP121A ANSI/UL1449 Third Edition, Type 2 Mounting HSP121BT-1RU Holes 3/16" Dia. Light On Normal Light Off Requires Service Mounting HSP121A Holes 3/16" Dia. 3/4" Conduit Fitting 3/4" Conduit Fitting GND 1/2" Conduit Fitting N N 1/2" Conduit Fitting AC GND AC 27

30 Access Control Edco PC642 Series Zone/Loop/Data The Edco PC642 Series surge suppressor is a two-pair (four-wire) module implementing three-stage hybrid technology. This module addresses over-voltage transients with gas tubes and silicon avalanche components. In addition, sneak and fault currents are mitigated with resettable fuses (PTCs). The PTCs increase resistance by several orders of magnitude when over-currents exceed safe levels. A normal state resumes when over-currents are removed. The ability to self-restore in this manner significantly increases suppressor performance and survivability. EDCO PCB1B BASE SOLD SEPARATELY OPTION: DIN RAIL KIT AVAILABLE ORDER PART # 11604KIT-PC The Edco PC642 Series card edge module is gold plated, double sided, and is designed to mate with the Edco PCB1B gold-plated female terminal connector. When snapped together, the data circuits pass thru the protector in a serial fashion from the four Field Side terminals to the four Electronics Side terminals. Terminals 1 or 10 of the Edco PCB1B must be attached to Building- Approved Ground per Edco Technical Bulletin # Three-stage hybrid protection Sneak/fault current protection Resettable fusing PTCs Low capacitance option Plug-in module Fast response time Requires Edco PCB1B base Order PC642PTU an invaluable troubleshooting tool 5, 12, 18, 24, 30, 36, 43, 52, 180 VDC 8, 15, 20, 30, 36, 43, 50, 60, 200* VDC Operating Current 0.15A 10 ka (8 x 20 µs) 0 to 20 MHz < 0.1 db at 20 MHz GDT, SAD, w/series PTC Terminal Block w/compression Lugs Terminals Accept Up To 10 AWG Dimensions (Inches) 2H x 1W x 2.5L (PC642 + PCB1B Base) Certification 1 oz UL 497B * PC642C-200 is not UL certified Caution: The hybrid design of this product includes series resistance. Do not place this product in service on any signal line capable of supplying more than 150 milliamperes continuously. Terminal Assignments Unprotected Pair 2 Field Side Unprotected Pair 1 Odd Terminals { { PCB1B: 1.0 Even Terminals } Protected Pair 2 Electronics Side 2.125" 2.4" 2 } Protected Pair 1 Keying Pin Ground Terminal 1 Or 10 To Building-Approved Ground DO NOT daisy chain grounds. NOT intended for shield termination. Install ground in accordance with all applicable codes. PC642 PCB1B APPLICATION: RS485, RS422: PC642C-008LC & PCB1B RS423, Token Ring: PC642C-008LC & PCB1B RS232: E-Net, 10 Base T: PC642C-020 & PCB1B PC642C-030LC & PCB1B 4 20 ma: PC642C-036 & PCB1B How To Specify The Appropriate Model PC642C - Voltage Clamp 8 Volts Volts Volts Volts Volts Volts Volts Volts **200 Volts **Not UL Listed no suffix stage 2 clamp each line-to-ground stage 2 clamp D line-to-line only stage 2 clamp line-to-line X and each line to ground low capacitance option stage LC 2 clamp line-to-line and each line to ground 28

31 Access Control Edco LCDP Data Circuit Protection The Edco LCDP Series is designed to conveniently protect 8 wire, low voltage, data circuits and employs two RJ-45 jacks for easy installation. The Edco LCDP utilizes silicon avalanche (solid-state) suppression technology and exhibits very low capacitance to accommodate high data rates. This unit supports high-speed data rates of over 100 Mbps. <1 nanosecond response time Line-to-line protection Low capacitance RJ-45/4 pair protection (8 wire) Silicon avalanche design Line-to-ground protection 5, 12, 24, 48, 65 VDC 8, 15, 30, 60, 75 VDC Operating Current 1.5A (10 x 1000 µs) 008 = 125A, 015 = 72A, 030 = 22A, 060 = 18A, POE*=15A 0 to 100 MHz < 0.1 db at 50 MHz Silicon Avalanche Diode (SAD) RJ-45 Jacks Dimensions (Inches) 1.0H x 2.5W x 4.25L Certification * LCDP-POE is not UL certified 3 oz UL 497B Installation The user equipment plugs into the LCDP s equipment (protected) side, and the LCDP s line (unprotected) side is connected to the incoming line. All 8 conductors are protected. The green ground wire must be bonded to the protected equipment power ground (third wire, green wire safety ground). Do not add length to the ground wire, since it must be kept as short as possible. Model LCDP-008 LCDP-015 LCDP-030 LCDP-060 LCDP-POE* 8 Volts 15 Volts 30 Volts 60 Volts 75 Volts 29

32 Communications Edco FAS-1 and FAS-2 Series One- and Two-Pair Signal Line Protection The Edco FAS-1 and Edco FAS-2 Series are multi stage one-pair or two-pair surge suppressors designed for high-exposure applications. These products were specifically designed to meet multiple, low voltage, protection applications in the fire and security industries. Lightning protection for low voltage Data/signal lines Multi stage protection Common mode and differential protection mode Automatic recovery 15, 24, 36, 52 VDC 18, 33, 43, 60 VDC Operating Current 2.5A 10 ka (8 x 20 µs) 0 to 10 MHz < 0.1 db at 10 MHz GDT, SAD, w/series Inductor Terminal Block w/compression Lugs Terminals Accept Up To 12 AWG -40 C to +85 C Dimensions (Inches) FAS-1 = 1.5H x 1.5W x 2.8L FAS-2 = 2H x 2W x 2.8L FAS-1 = 3.5 oz FAS-2 = 7 oz Certification UL 497B Installation Unprotected Or Field Side Ground Lug AWG < 3 Equip. Line FAS HC (One-pair) FAS HC (Two-pair) FAS HC (One-pair) FAS HC (Two-pair) FAS HC (One-pair) FAS HC (Two-pair) FAS HC (One-pair)* FAS HC (Two-pair)* *Not UL listed 12VDC Use 24VDC Use 24VAC Use 48V Systems Use Caution: The hybrid design of this product includes series resistance. Do not place this product in service on any signal line capable of continuously supplying more than 2.5 amperes. Protected Equipment DO NOT daisy chain grounds. NOT intended for shield termination. Install ground in accordance with all applicable codes. 30

33 Communications Edco DRS (DC) Series DIN Rail Protection The Edco DRS (DC) Series is a din rail mountable, single-pair surge suppression module implementing three-stage hybrid technology. This module addresses over-voltage transients with gas tubes and silicon avalanche components. In addition, sneak currents are mitigated with resettable fuses (PTCs). The PTCs increase resistance several orders of magnitude when over-currents exceed safe levels. A normal state resumes when over-currents are removed. The ability to self-restore in this manner significantly increases suppressor performance and survivability. The Edco DRS (DC) Series mounts onto a standard 35 mm industrial DIN rail. There are three Field Side and three Electronics Side screw terminals. One is reserved for a shield. Three electrically tied ground terminals are provided for grounding the Edco DRS (DC) Series unit to Building-Approved Ground. Shield is isolated from ground. For a 2-terminal version without a shield, order the Edco DRS-XXX-2. Low-voltage data surge protection Three-stage hybrid protection Sneak/fault current protection with resettable fuses PTCs Low profile packaging UL 497B listed Easy installation Fits standard 35 mm DIN rail Fast response time < 1 nanosecond Maximum Nominal Surge Peak Current Typ Maximum Nominal Part Peak Signal Breakdown 1p 10 x 1000 µs 8 x 20 µs Cap Continuous Series Number Voltage Voltage Current Waveform (pf) Current (ma) Resistance DRS > ka Ohms DRS > ka Ohms DRS > ka Ohms DRS > ka Ohms DRS > ka Ohms DRS > ka Ohms DRS > ka Ohms DRS > ka Ohms *DRS >10 8 ka Ohms **DRS >10 8 ka None Dimensional Diagrams DRS-XXX *Not UL 4978 Listed **Warning!! DRS-130RMS is for discrete signal use only. Do not use DRS-130RMS on 120 VAC power lines. This unit is a nonhybrid, MOV design, rated above 5A operational current and can withstand greater than eight occurrences of a 10 ka (8 x 20 µs) waveform, and greater than 1,000 occurrences of a 200A 10 x 1000 µs waveform. DRS-XXX-2 (2 Terminal Version) 31

34 Communications Edco CX-HFN High Frequency Coax Protector N-Type The Edco CX-HFN surge protectors are designed to protect sensitive electronic equipment from damage due to excessive voltage or currents generated by lightning or static buildup. The Edco CX-HFN offers low signal loss at frequencies up to 3 gigahertz. The Edco CX-HFN accommodates both bulkhead mount and stud mount. The input and output connections are interchangeable. Operating Current 130 VDC 150 VDC (DC Spark Over Voltage) 1A 10 ka (8 x 20 µs) 0 to 4 GHz < 0.5 db 2 to 3 GHz Gas Discharge Tube (GDT) Female N-Type Dimensions (Inches) 1.25H x.875w x 2.5L 4 oz CX-HFN-FM Female to Male CX-HFN-FF Female to Female Edco CATV-DF High Frequency Coax Protector F-Type The Edco CATV DF surge protectors are designed to protect sensitive electronic equipment from damage due to excessive voltage or currents generated by lightning or static buildup. Applications include direct broadcast satellite systems, HDTV, and cable modems. The Edco CATV DF offers low signal loss at frequencies up to 2 gigahertz. Incorporates GDT (gas discharge tube) technology. Automatic recovery Low insertion loss Shielded case Easily installed 25 VDC 0 to 2 GHz Operating Current 150 VDC (Spark Over Voltage) 1A < 1.0 db at 1 GHz < 2.0 db at 2 GHz Gas Discharge Tube (GDT) Dimensions (Inches) 1.25H x 2.5W x 4L 3 oz 10 ka (8 x 20 µs) Type F Female 32

35 Communications Edco OPX Series Intercom/Speaker Punch Block Protection (Parallel) Medium Exposure Applications The Edco OPX Series surge protectors are specifically designed for mediumexposure applications. Thus, the protectors can be used on pairs inside a building or leaving the build ing, in conduit up to 500 feet. These protectors are intended to be used in conjunction with the Edco MGB Ground Rail and a standard MI-50 Punch Down Block. The Edco OPX Series offers several, distinct advan tages over other current technologies. Among the advantages are low cost, no series resis tance, and durable solid-state construction. Over-current protection Replaces bridging clips on MI-50 block UL 497B listed Utilizes MGB grounding rail Test point accessible 12, 24, 42, 12, 35 VDC Operating Current 15, 30, 48, 15, 56 VDC 2A 015 =125A, (10 x 1000 µs) 030 = 71A, 048 = 45A, CLN = 125A, SPK = 500A, 8 x 20 µs Insertion loss 0 to 20 MHz < 0.1 db at 20 MHz Silicon Avalanche Diode (SAD), OPX-SPK Model Uses MOV Clip Dimensions (Inches) 1.25H x 0.375W x 2.0L Certification 1 oz UL 497B Installation MI-50 Block Test Points How To Specify The Appropriate Model DO NOT daisy chain grounds. NOT intended for shield termination. Install ground in accordance with all applicable codes. O P X C L N S P K Clamping Voltage 15 Volts 30 Volts 48 Volts 15 Volts (Call-In Circuit) 56 Volts (Speaker Circuit) 33

36 Communications Edco PB Series Intercom/Speaker Punch Block Protection (Series) The Edco PB modules are solid-state protectors for intercom extension pairs. As a new alternative to the OPX, the standard EDCO intercom protector, the PB adds fusing and a new component layout. These hybrid protectors are intended to be used in conjunction with the EDCO MGB ground rail and a standard MI-50 punch down block. The PB modules feature solid-state resettable fuses (PTCs) between the protected equipment and the over voltage clamping components. This unique design prevents problems with All-Call in the event of catastrophic protector failure. Patented Technology Over current protection Replaces bridging clips on M1-50 bock UL 497B listed Utilizes MGB grounding rail Test point accessible Installation 12, 56 VDC 21, 70 VDC Operating Current 0.15A PBCLN = 0.2 ka, PBSPK = 0.5 ka (10 x 1000 µs) 0 to 20 MHz PBCLN = SAD w/series PTC, PBSPK = MOV w/series PTC < 0.1 db at 20 MHz Clip Dimensions (Inches) 1.25H x 0.4W x 2.8L Certification 1 oz UL 497B MI-50 Block Test Points PBCLN Call-In Circuit PBSPK Speaker Circuit See technical Bulletin # 2017 Caution: The hybrid design of this product includes series resistance. Do not place this product in service on any signal line capable of continu ously supplying more than 150 ma. TTA-2: Test Point Plug Available DO NOT daisy chain grounds. NOT intended for shield termination. Install ground in accordance with all applicable codes. 34

37 Communications Edco H Series Telecom/Punch Block Protection Advanced Ultra High Speed Technology Patented Technology The Edco H Series modules are ultra high speed, fused, solid state, secondary protectors for KEY/PABX systems. The units are available in three different clamping voltages. The Edco H Series is constructed with solid state silicon foldback technology, polyswitch resettable fuses PTCs and failure fuses. These protection modules are intended to be used in conjunction with proper primary protectors (UL 497A). The protective elements switch from the normal high-impedance state to a low-impedance state upon a detection of a surge, then switch back to high impedance after the surge has passed. The Edco H Series single-pair modules fit onto a standard Edco MI-50 split block and replace bridging clips. In addition, these modules require the Edco MGB Ground Rail for each Edco MI-50 block used. 50, 180, 230 VDC 65, 200, 270 VDC Operating Current 0.15A 160A (10 x 1000 µs T & R to Ground) 0 to 20 MHz < 0.1 db at 20 MHz Silicon Breakover Device w/series PTC Clip Dimensions (Inches) 1.25H x 0.4W x 2.8L Certifications 1 oz UL 497A, CUL Installation MI-50 Block HCO Central Office/Trunk HAE Analog Extension HDE Digital Extensions Unprotected Side Terminate Field Side Wiring Coming Into Building On The Unprotected Side DO NOT daisy chain grounds. NOT intended for shield termination. Install ground in accordance with all applicable codes. 35

38 Communications Edco COHP Series Data/Signal Line/Punch Block Protection High-Exposure Applications The Edco COHP modules are three-stage hybrid protectors for low-voltage data and telecommunications applications. The modules address over-voltage transients with gas tubes and silicon avalanche components. In addition, sneak and fault currents are mitigated with resettable fuses (PTCs). Intended to be used on pairs without the presence of ring ing voltage. The Edco COHP modules are designed for data and control applications as an isolated loop circuit protector. Replaces bridging clips on MI-50 Block <1 nanosecond response time Line-to-line protection Line-to-ground protection Utilizes MGB grounding rail Rugged, three electrode, gas tube, first stage Silicon avalanche hybrid technology Polyswitch resettable fusing PTCs 6, 12, 20, 24, GDT, SAD, w/ Series PTC Model 43, 52 VDC Clip COHP Volts 8, 15, 20, 30, 50, 60 VDC COHP Volts Operating Current 0.15A Dimensions (Inches) 1.25H x 0.4W x 2.8L COHP Volts 10 ka (8 x 20 µs) 1 oz COHP Volts 0 to 20 MHz Certification UL 497B COHP Volts < 0.1 db at 20 MHz COHP Volts Edco MGB Ground Rail Fits Standard 66MI-50 Punch Down Blocks Split Block Variations The Edco MGB Ground Rail designed to fit standard 66MI-50 Punch Down Blocks. Allows Edco s H Series, COHP, OPX, PB Series and other similar surge suppressors to access ground when snapped onto the 66MI-50 Punch Down Block. The Standard 66MI-50 Block is capable of accommodating up to 25 Edco surge suppressors. Protected Unprotected U.S. Patent No. 4,703,983 MI-50 Block DO NOT daisy chain grounds. NOT intended for shield termination. Install ground in accordance with all applicable codes. Edco Recommends A 10AWG Wire To Building-Approved Ground Keep Short 36

39 Communications Edco FAS-TEL and FAS-31XT RJ11/RJ31X Telephone Protection The Edco FAS-TEL and Edco FAS-31XT are single-pair telephone or data line protectors that implement advanced two-stage hybrid design. These units address over-voltage transients with silicon breakover devices, while sneak and fault currents are mitigated with PTC technology which consists of solid state resettable fuses. The Edco FAS-31XT replaces the RJ31X jack with a protected version. Four screw terminals are provided to wire the protector in the same manner as a standard RJ31X jack. The Edco FAS-TEL is nearly identical to the Edco FAS-31XT except with out the shorting bars. Two screw terminals are provided to connect the incoming telephone line to the protector. Protected equipment such as modems are plugged into the female modular jack on the Edco FAS-TEL. <1 nanosecond response time Solid-state silicon breakover technology Low capacitance Over current protection UL 497A listed Line-to-line protection Line-to-ground protection Polyswitch resettable fuses PTCs How To Specify The Appropriate Model 12, 24, 43, 52, 180, 220, & 220 VDC 15, 30, 50, 60, 200, 270 & 300 VDC Operating Current 0.15A Dimensions (Inches) Certifications FAS-TEL-060T FAS-TEL-200T FAS-31XT FAS-TEL-DSL 160A (10 x 1000 µs T & R to Ground) 0 to 20 MHz < 0.1 db at 20 MHz Silicon Avalanche Diode w/ Series PTC Terminal Block w/compression Lugs In/ RJ Connector Out 1H x 2W x 2L 2 oz UL 497A, CUL Digital Phone Analog Phone/Fax/Modem Alarm System Phone DSL F A S - T E L - T F A S X T F A S - T E L - D S L Clamping Voltage 15 Volts 30 Volts 50 Volts 60 Volts 200 Volts 270 Volts 300 Volts 37

40 Communications MODEL SHOWN 48 CAT6-POE Edco RM-CAT6-POE Series Multi-Channel Rackmount The Edco RM-CAT6-POE Series is a modular, high speed, data-line protector that utilizes a three-stage hybrid design technology. This unit addresses highenergy voltage transients that can damage expensive computer equipment. Ideal for network switches and hubs, the Edco RM-CAT6-POE Series is easily mounted in close proximity to the protected equipment. Exceeds Category 6 transmission values Compact 1U rack size Replaceable surge modules Low insertion loss Offered in 16 or 48 channel protection* Three-stage hybrid Meets POE requirements 1 year warranty *Other configurations available. Consult factory. 57 VDC 68 VDC MHz Operating Current 0.15A Modes of Protection GDT, SAD, W/Series PTC Signal High-Low Signal High-Ground, Signal Low-Ground 10 ka (8 x 20 µs) <0.1dB VSWR <1.2 Operating Humidity 0-95% Non-Condensing Input RJ-45 Output RJ-45 Mounting Rackmount Enclosure Type Painted Steel Dimensions 1.75Hx19Wx6.3D 5.5 lbs. Edco LCDP Data Circuit Protection The Edco LCDP Series is designed to conveniently protect 8 wire, low-voltage data circuits and employs two RJ-45 jacks for easy installation. The Edco LCDP utilizes silicon avalanche (solid-state) suppression technology and exhibits very low capacitance to accommodate high data rates. This unit supports high-speed data rates of over 100 Mbps. <1 nanosecond response time Line-to-line protection Low capacitance RJ-45/4 pair protection (8 wire) Silicon avalanche design Line-to-ground protection 5, 12, 24, 48, 65 VDC 8, 15, 30, 60, 75 VDC Operating Current 1.5A (10 x 1000 µs) 008 = 125A, 015 = 72A, 030 = 22A, 060 = 18A, POE*=15A 0 to 100 MHz < 0.1 db at 50 MHz Silicon Avalanche Diode (SAD) RJ-45 Jacks Dimensions (Inches) 1.0H x 2.5W x 4.25L Certification 3 oz UL 497B (*except LCDP-POE) Installation The user equipment plugs into the LCDP s equipment (protected) side, and the LCDP s line (unprotected) side is connected to the incoming line. All 8 conductors are protected. The green ground wire must be bonded to the protected equipment power ground (third wire, green wire safety ground). Do not add length to the ground wire, since it must be kept as short as possible. LCDP-008 LCDP-015 LCDP-030 LCDP-060 LCDP-POE 8 Volts 15 Volts 30 Volts 60 Volts 75 Volts 38

41 Communications Edco RJA-RJD Series RJ-45 Telephone/Data The Edco RJA and Edco RJD Series are four-pair telephone/data-line protectors that implement advanced, two stage, hybrid design. These units address over voltage transients with silicon breakover devices, while sneak and fault currents are mitigated with PTC technology, which consists of solid state resettable fuses. The Edco RJA and Edco RJD Series incorporate Edco RJ-45 female jacks in and out. The Edco RJA voltage clamp is set for C.O. Trunks and analog telephone extensions (with ring in voltage), and the Edco RJD voltage clamp is set for digital extensions (no ring in voltage). <1 nanosecond response time Solid-state resettable fuses PTCs Silicon breakover technology Low capacitance Line-to-line protection Tip- and ring-to-ground protection CAN/CSA C22.2, No compliant UL 497A listed 4 pair protection Installation 48, 220 VDC 55, 280 VDC Operating Current 0.15A 200 A (10 x 1000 µs) 0 to 50 MHz < 0.1 db at 50 MHz Silicon Breakover Devices w/series PTC RJ-45 Jacks Dimensions (Inches) 1.0H x 2.5W x 4.25L Certifications 3 oz UL 497A, CUL Gnd. Analog Phone Digital Phone Building- Approved Ground RJA-45 RJD-45 The Edco RJA and Edco RJD Series are intended for indoor use only and shall be employed on the equipment side of a listed primary telephone protector. 39

42 Communications Edco TBLK Assembly Terminating Assembly The Edco TBLK is a high-density assembly designed to house up to 12 or 25 individual Edco surge protec tion modules. Standard Edco H Series, COHP, OPX, PB Series, and other similar modules (separately ordered) are suitable for the Edco TBLK assembly. The Edco TBLK is capable of terminating solid or strand ed 26 to 14 AWG wire using compression terminal screws. Dimensions DO NOT daisy chain grounds. NOT intended for shield termination. Install ground in accordance with all applicable codes. Edco CAT6-5POE Series CAT6/CAT5 Power Over Ethernet The Edco CAT6-5POE Series is designed to work on Category 5 Power-Over- Ethernet transmission lines as well as Category 6 applications. Ideal to protect expensive equipment against surges and transients entering a building on exposed transmission lines. Available in both female to female and male to female RJ-45 connectors. Exceeds CAT5 & 6 transmission values CAT5 POE compatible CAT6 compatible Applications up to ma 1 year warranty Operating Voltage 60 VDC RJ-45 Jacks RJ-45 (FF) CAT6-5POE-FF 65 VDC RJ-45 (MF) CAT6-5POE-MF Operating Current 300 ma 60A (10 x 1000 µs) 0 to 250 MHz Dimensions (Inches) 0.8H x 1.0W x 2.3L (FF). 0.8H x 1.0W x 3.0L (MF) 1 oz < 0.1 db at 20 MHz Silicon Avalanche Diode (SAD) 40

43 Communications Edco MOD-12 Key Systems The Edco MOD-12 Tip/Ring protection for Key/PBX Systems. This innovative design creates an automatic ground window, thus eliminating the problem of ground potential difference. Edco H Series Protector Modules readily snap onto the Edco MOD-12. Protection is expandable from 1 to 12 pairs in single-pair increments and is field upgradable. In addition, test points are provided on each pair. 1 to 12 pair expansion Replaceable single-pair protection modules Punch down block (66 type) Test points Protective transparent cover UL 1363 listed AC Protection Options Application Diagram 1. Basic internal surge protection (standard) 2. Plug-in hybrid surge protection HAE or HDE (One Per Extension) HCO (One Per CO TRUNK) Existing Telco Primary Protection Demarc 66 Block Tip/Ring Or Data Protection 1. Incoming C.O. lines use HCO 2. Analog extensions use HAE 3. Digital extensions use HDE HAE HDE MGB Ground Rail KSU MOD-12 CO TRUNKS MOD-12 Base Assembly Chassis Ground Cable Shield Ground To AC Building-Approved Ground DO NOT daisy chain grounds. NOT intended for shield termination. Install ground in accordance with all applicable codes. 41

44 Headquarters Surge Protection 100 Emerson Parkway Binghamton, NY T: T: F: E: Emerson Network Power. The global leader in enabling Business-Critical Continuity TM. EmersonNetworkPower.com/surge AC Power Connectivity DC Power Embedded Computing Embedded Power Monitoring Outside Plant Power Switching & Controls Precision Cooling Racks and Integrated Cabinets Services Surge Protection Business-Critical Continuity, Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co Emerson Electric Co. While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. SL Rev.1 8/10 Printed in USA

Surge Protection For Business-Critical Continuity TM. Communications/Data/Signal Line Surge Protection Product Catalog

Surge Protection For Business-Critical Continuity TM. Communications/Data/Signal Line Surge Protection Product Catalog Surge Protection For Business-Critical Continuity TM Communications/Data/Signal Line Surge Protection Product Catalog Mission-Critical Voice and Data Signal Protection Unmatched Protection for Peace of

More information

SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC INTEGRATED SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671A SECTION 16671A

SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC INTEGRATED SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671A SECTION 16671A SURGE PROTECTIVE DEVICES (SPDs) INTEGRATED UNITS LOW VOLTAGE AC SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS PART 1 GENERAL 01 02 03 SCOPE The Contractor shall furnish and install the Surge Protective

More information

Power surges can also be generated by equipment in your facility such as:

Power surges can also be generated by equipment in your facility such as: Power Quality Surge Suppressors What is Surge Protection A surge suppressor can be the first and best defense against the instant or gradual destruction of electrical equipment. Compared to the replacement

More information

CPS 100 480Y S K CPS 100 480Y S C

CPS 100 480Y S K CPS 100 480Y S C Ref. No. 1299 Visor Series Ordering Guidelines Table.1-4. Retrofit Surge Protection Products TVSS General Description Clipper Power System Visor Series CPS 100 480Y S K.1-9 Surge Ratings 100 = /phase 120

More information

Applications. Remote Display Mounting Kits

Applications. Remote Display Mounting Kits June 200 Sheet 105 Surge Protection Products TVSS General Description Clipper Power System Visor Series.1-5 Clipper Power System Visor Series General Description Eaton s Cutler-Hammer leading-edge surge

More information

Project Name: Nortrax Section 26 41 00 Project No: 13-013 SURGE PROTECTION DEVICES Page 1

Project Name: Nortrax Section 26 41 00 Project No: 13-013 SURGE PROTECTION DEVICES Page 1 Page 1 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. General: Drawings and general provisions of the Contract, including General and Supplementary Conditions and Divisions 1 Specification sections apply to

More information

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments Model #: SM2000RMX Heavy-duty, industrial-grade metal housings Shock and vibration rated to MIL-STD-810D 19 inch

More information

LC03-6. Low Capacitance TVS for High-Speed Data Interfaces. Features. Description. Mechanical Characteristics. Applications

LC03-6. Low Capacitance TVS for High-Speed Data Interfaces. Features. Description. Mechanical Characteristics. Applications Description The LC0- transient voltage suppressor is designed to protect components which are connected to high speed telecommunication lines from voltage surges caused by lightning, electrostatic discharge

More information

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual 5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual Content Overview... 1 Introduction... 1 Features... 3 Packing List... 4 Safety Precaution... 4 Hardware Description... 5 Front Panel...

More information

Telecommunication Line Protectors

Telecommunication Line Protectors TN CR 0025 Telecommunication Line s 1.1 The nature of telecom surges The telecom services considered in this report are transported on twisted pair. Each service has two wires, or lines, sometimes called

More information

A series of technology briefs spanning Tyco Electronics product portfolio

A series of technology briefs spanning Tyco Electronics product portfolio A series of technology briefs spanning Tyco Electronics product portfolio Coordinated Circuit Protection Schemes Help Prevent Overvoltage and Overcurrent Damage Through advances in materials science and

More information

SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC EXTERNAL SIDEMOUNT SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671B SECTION 16671B

SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC EXTERNAL SIDEMOUNT SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671B SECTION 16671B SURGE PROTECTIVE DEVICES (SPDs) EXTERNAL SIDEMOUNT UNITS LOW VOLTAGE AC SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION PART 1 GENERAL 01 02 03 SCOPE The Contractor shall furnish and install the Surge Protective

More information

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY 7320 Ashcroft, Suite 104 Houston, Texas 77081 p: 713-772-1404 f: 713-772-7360 e: [email protected] www.juicegoose.com 06-06 CONGRATULATIONS

More information

Intersection Preassembled 19-inch Rack

Intersection Preassembled 19-inch Rack Intersection Preassembled 19-inch Rack The intersection preassembled 19-inch rack comes fully assembled, wired and ready to be installed in a server rack. The rack provides communications, power conversion

More information

MLH REVISIONS NOTICE: THE INFORMATION AND DESIGN CONTAINED HEREIN IS THE PROPERTY OF TRANSTECTOR SYSTEMS. WHO RESERVES ALL

MLH REVISIONS NOTICE: THE INFORMATION AND DESIGN CONTAINED HEREIN IS THE PROPERTY OF TRANSTECTOR SYSTEMS. WHO RESERVES ALL THIS DRWING HS BEEN GENERTED ND IS MINTINED BY CD SYSTEM. CHNGES SHLL ONLY BE INCORPORTED S DIRECTED BY THE DESIGN CTIVITY. REVISIONS LTR DESCRIPTION ECO NUM. DTE PPROVED B PRELIMINRY RELESE DD057 7/25/07

More information

SECTION 16720 - FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

SECTION 16720 - FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines PART 1 -- GENERAL 1.1 WORK OF THIS SECTION SECTION 16720 - City of San Diego, CWP Guidelines A. The WORK of this Section includes providing manual and automatic fire alarm and smoke detection systems meeting

More information

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1. USER GUIDE Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator Version 1.3 DM Engineering 2174 Chandler St. Camarillo, CA 91345-4611 805-987-7881 800-249-0487

More information

Video Camera Installation Guide

Video Camera Installation Guide Video Camera Installation Guide The intent of this guide is to provide the information needed to complete or modify a video camera installation to avoid lightning and induced power surge damage. This guide

More information

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410 The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a

More information

EQUIPMENT SPECIFICATIONS

EQUIPMENT SPECIFICATIONS EQUIPMENT SPECIFICATIONS IC-1600 Intelligent Controller The IC-1600 Intelligent Controller is a fully intelligent panel that has a complete database on board. It operates in conjunction with the Access

More information

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application 33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3at Standard -40 to +60 C Temperature Range Diagnostic LEDs Full Protection

More information

ST Series POWER SUPPLIES USER INSTRUCTIONS

ST Series POWER SUPPLIES USER INSTRUCTIONS Introduction These instructions detail the installation and operation requirements for the ST20 & ST35 power supplies. These have been designed for operation in RV s providing a DC power system, with optional

More information

RC NETWORKS SALES GUIDE

RC NETWORKS SALES GUIDE SALES GUIDE INTRODUCTION TO Recent developments in electronic equipment have shown the following trends: Increasing demands for numerical control machines, robotics and technically advanced appliances

More information

LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification

LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification 08/17/12 Rev2 LTR Series General Specification 700 VA to 2.1 KVA 1.0 General LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA General Specification This specification describes the features and

More information

HM-W536 Install Guide

HM-W536 Install Guide HM-W536 Install Guide 9/13/2013 IMPORTANT SAFETY INSTRUCTIONS Warning - When using electrical devices, basic safety precautions should be followed to reduce the risk of fire, electrical shock or injury.

More information

DDX 7000 & 8003. Digital Partial Discharge Detectors FEATURES APPLICATIONS

DDX 7000 & 8003. Digital Partial Discharge Detectors FEATURES APPLICATIONS DDX 7000 & 8003 Digital Partial Discharge Detectors The HAEFELY HIPOTRONICS DDX Digital Partial Discharge Detector offers the high accuracy and flexibility of digital technology, plus the real-time display

More information

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................

More information

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points Features SELV Compliant No Detection Passive Injector Gigabit Compatible Full Protection

More information

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Features: INSTALLATION Install in accordance with NFPA 70. DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short

More information

KZ0224UW INSTALLATION MANUAL SURGE PROTECTED CCTV POWER SUPPLY 24V AC, 5 AMP KZMI000549 11/12/01

KZ0224UW INSTALLATION MANUAL SURGE PROTECTED CCTV POWER SUPPLY 24V AC, 5 AMP KZMI000549 11/12/01 KZ0224UW SURGE PROTECTED CCTV POWER SUPPLY 24V AC, 5 AMP INSTALLATION MANUAL KZMI000549 ISSUE DATE REVISIONS 1 November 2001 Initial release. 2001 BY ULTRAK ALL RIGHTS RESERVED ULTRAK CORPORATE OFFICE

More information

BLUE RIBBON CORP. BC001 Birdcage Installation Manual

BLUE RIBBON CORP. BC001 Birdcage Installation Manual Product Overview: This manual is applicable for the BC001 Birdcage Submersible Level Transmitters. If the product you have has a different prefix part number than listed above please contact the factory

More information

LOXONE 12 Channel Amplifier

LOXONE 12 Channel Amplifier LOXONE 12 Channel Amplifier Item no.: 200110 Thank you for purchasing the Loxone Twelve Channel Amplifier. The versatility of the Amplifier makes it the perfect choice for almost every type of custom multi-room

More information

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W) Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W) Table of Contents Introduction.. Power Over Ethernet (PoE) & Features.... Unpacking and

More information

LIEBERT VNSA Installation Sheet

LIEBERT VNSA Installation Sheet LIEBERT VNSA Installation Sheet Description The Liebert vnsa network switch is designed for connecting multiple Ethernet-ready devices and comes in various models. The unit may have: A Liebert icom display

More information

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies. www.stacoenergy.com

Product Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies. www.stacoenergy.com Popular Variable Transformers and AC Power Supplies Product Guide AC Voltage Control Devices Guide Guide Your Tailored Power Solutions Provider TM Staco Energy Products Co. has been a leading manufacturer

More information

Surgelogic Surge Protection Device EMA, EBA, and HWA Series

Surgelogic Surge Protection Device EMA, EBA, and HWA Series Surgelogic Surge Protection Device EM, EB, and HW Series atalog 1310T0202R5/07 2007 lass 1310 OTETS Description..............................................Page Product Descriptions..........................................

More information

MCR1900 Media Converter 19-Slot Chassis

MCR1900 Media Converter 19-Slot Chassis MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the

More information

TrueAlarm Fire Alarm Systems

TrueAlarm Fire Alarm Systems TrueAlarm Systems UL, ULC, CSFM Listed; FM Approved* Network Annunciators; es Features Provides a dedicated local area network (LAN) for connection of a TrueSite workstation server to remote clients: es

More information

Surgelogic Surge Protective Device (SPD)

Surgelogic Surge Protective Device (SPD) Surgelogic Surge Protective Device () EB, EM, and HW Series atalog 1310T0202R05/09 2009 lass 1310 OTETS Description............................................. Page Product Description...........................................2

More information

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02 IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB6444-02 TABLE OF CONTENTS DESCRIPTION 2 MOUNTING INSTRUCTIONS 2 HOW TO CABLE THE IPX 2/3 POWER SUPPLY INSTALLATION 3 OPERATION 3 CARE

More information

SECTION 13850 DETECTION AND ALARM

SECTION 13850 DETECTION AND ALARM SECTION 13850 DETECTION AND ALARM PART 1 GENERAL 1.01 SUMMARY A. Section Includes 1. Control Panel 2 Associated Equipment B. Products Installed But Not Supplied Under This Section 1. Section 16140 - Wiring

More information

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils

More information

ADACSNET USB Control Module

ADACSNET USB Control Module ADACSNET USB Control Module Installation Guide Termination Switch 2-Pin SensorNet Connection Features and Hookup The USB Control Module contains the following: - USB port: Connects to the host computer.

More information

Uninterruptible Power Supply

Uninterruptible Power Supply 96-01101 / rev. 2e / 2-2-12 Uninterruptible Power Supply EXCEPTIONAL SUPPORT & PROTECTION Uninterruptible Power Supply with Energy Saver design that is optimized to address the needs of A/V systems Features

More information

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power) MODEL NUMBER: ISC910-1-0-GB-XX ISC911-5-0-GB-XX IXP20 CONTROLLER SPECIFICATIONS Working Environment Plastic Housing... Power ImproX IXP20 Controller INSTALLATION MANUAL Designed to work in an indoor (dry)

More information

Protect your home and family with Advanced Technology from Cutler-Hammer

Protect your home and family with Advanced Technology from Cutler-Hammer Protect your home and family with Advanced Technology from Cutler-Hammer Residential Home Fire Statistics Annually - over 415,000 Residential Fires Annually - over 40,000 electrical fires over 350 deaths

More information

LocoNet, the Digitrax Difference

LocoNet, the Digitrax Difference LocoNet, the Digitrax Difference LocoNet is Digitrax's method of communication between LocoNet compatible devices on a model railroad layout. LocoNet Compatible devices are designed to work together on

More information

SMART SENSOR COLLECTION

SMART SENSOR COLLECTION TEMPERATURE SENSOR This sensor measures temperature in degrees Celsius or Fahrenheit. It works with all SensorHawk base units (SensorHawk-2, SensorHawk-8 and SensorHawk8/20) as well as the SecurityHawk-8

More information

MTL Surge Technologies. Product Overview

MTL Surge Technologies. Product Overview MTL Surge Technologies Product Overview Surge Protection Devices Today s modern electronic systems, such as those designed for process control and high-speed communication, rely heavily on very sensitive,

More information

LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual LevelOne IFE-0500 4-Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual Ver. 1.0.0-0711 1 FCC Warning This Equipment has been tested and found to comply with the limits for a Class-A digital

More information

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0. 48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according

More information

Mobile Data Power Model: MDP-25

Mobile Data Power Model: MDP-25 Mobile Data Power Model: MDP-25 Topic Section Features... 2 Operational Features Summary... 2 Back-up Battery Power Internal Charger Voltage Spike Protection RF Noise Filtering Warning of Imminent Loss

More information

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty. 1.1. Safety notes. 1.2. Policy. 1.3. Warranty.

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty. 1.1. Safety notes. 1.2. Policy. 1.3. Warranty. Whale 3 DC Servo drive User Manual and Installation Guide Contents 1. Safety, policy and warranty. 1.1. Safety notes. 1.2. Policy. 1.3. Warranty. 2. Electric specifications. 2.1.Operation ranges. 3. Connections

More information

SURGE PROTECTIVE DEVICES

SURGE PROTECTIVE DEVICES SURGE PROTECTIVE DEVICES 1. INTRODUCTION In order to ensure safety of people, protection of equipment and, to a certain extent, continuity of supply, insulation co-ordination aims at reducing the likelihood

More information

IP DSLAM IDL-2402. Quick Installation Guide

IP DSLAM IDL-2402. Quick Installation Guide IP DSLAM IDL-2402 Quick Installation Guide Table of Contents Package Contents... 3 Overview... 4 Setup the IDL series IP DSLAM... 5 Safety Instruction... 5 Hardware Installation... 6 WEB Configuration...

More information

AND8229/D. An Introduction to Transient Voltage Suppression Devices APPLICATION NOTE

AND8229/D. An Introduction to Transient Voltage Suppression Devices APPLICATION NOTE An Introduction to Transient Voltage Suppression Devices Prepared by: Jim Lepkowski ON Semiconductor APPLICATION NOTE INTRODUCTION Transient Voltage Suppression (TVS) protection devices such as shielded

More information

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit SLCLE5504AUX for Use with Wired C-Bus Networks Instruction Bulletin Retain for future use. Square D Clipsal DIN-Rail Four-Channel Auxiliary Input

More information

Rack mounted telephone- and leased line modem for industrial applications

Rack mounted telephone- and leased line modem for industrial applications Rack mounted telephone- and leased line modem for industrial applications TR-6 Rack modem for industrial PSTNand /-wire leased line applications The TR-6 is an analogue V. 9 -rack PSTN modem as well as

More information

No Phone Line II-48 System

No Phone Line II-48 System Used in conjunction with an EntraGuard Telephone Entry System, the -48 provides No Phone Line communication and door or gate control through existing building telephone lines without the need to purchase

More information

Reliability in Surge Protection. Security Systems. www.citel.fr

Reliability in Surge Protection. Security Systems. www.citel.fr Reliability in Surge Protection Security Systems www.citel.fr All devices used in security system are based on integrated circuit that is highly susceptible and vulnerable to lightning and switching surges.

More information

Self Monitoring Power Supply (BPSM)

Self Monitoring Power Supply (BPSM) LIFETIME REPLACEMENT WARRANTY Self Monitoring Power Supply (BPSM) Application - When interfacing with a fire alarm system where the system s auxiliary relay cannot handle the full current potential of

More information

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 [email protected] in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate

More information

TSn SERIES Surge Protective Device

TSn SERIES Surge Protective Device Page: 1 of 8 TSn SERIES Surge Protective Installation & Operation Manual 3621 Saunders Avenue www.systems.us Ph 804.355.1100 Richmond, VA 23227 4354 [email protected] Fax 804.355.8900 Page: 2 of 8 Quick

More information

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014 EZmoto V2 Product description Rev. 6 10/01/2014 1 Contents 1. Overview... 3 2. Hardware Interface Description... 3 2.1 Main features of the EZmoto... 3 2.2 Hardware block diagram... 4 2.3 Internal Hardware

More information

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems EN Security System CM705B CM705B - Universal Expander Module The CM705B universal expander provides a cost effective way

More information

INSTALLATION & SERVICE MANUAL. Display Panel

INSTALLATION & SERVICE MANUAL. Display Panel INSTALLATION & SERVICE MANUAL Display Panel The PowerLine EMS TM is a specialized power distribution and energy management system intended to be used in recreational vehicles. The Control Module is housed

More information

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE OASIS-PLUS 120V INFORMATION & OPERATING INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE 56041852 WARNING:

More information

Lighting Packages. 230 VAC Fluorescent Enclosure Light:

Lighting Packages. 230 VAC Fluorescent Enclosure Light: Spec-00581 H763.422.2211 763.422.2600 Electrical Lighting Packages Electrical Lighting Packages PANELITE Enclosure Lights Overview FEATURES Slim profile allows light to be tucked up out of the way for

More information

Application/Connection Examples

Application/Connection Examples This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.

More information

NetScanner System. Toronto: 416 754 7008, Montreal: 514 695 5147, Toll Free:1888 754 7008, Email: [email protected]; www.a-tech.ca

NetScanner System. Toronto: 416 754 7008, Montreal: 514 695 5147, Toll Free:1888 754 7008, Email: sales@a-tech.ca; www.a-tech.ca Networking Solutions NetScanner System 9IFC/90DB/90DC FEATURES Ethernet Interface for NetScanner System Modules Provides Power and Hardware Trigger Interface 10/100 Base-T Auto-Negotiating Universal AC

More information

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011 Instruction Manual 2in1 LAN Tester & Multimeter Model: LA-1011 1 Contents Introduction... Features... Safety Precautions.. Meter Description... Electrical Specification... Operation.. AutoRanging Multimeter.

More information

SPECIAL SPECIFICATION 6819 Wireless Ethernet Microwave Radio

SPECIAL SPECIFICATION 6819 Wireless Ethernet Microwave Radio 2004 Specifications CSJ 2266-02-127 SPECIAL SPECIFICATION 6819 Wireless Ethernet Microwave Radio 1. Description. Furnish and install Wireless Ethernet Microwave Radio (WEMR) as shown on the plans, as detailed

More information

HP UPS R1500 Generation 3

HP UPS R1500 Generation 3 HP UPS R1500 Generation 3 Installation Instructions Part Number 650952-001 NOTE: The rating label on the device provides the class (A or B) of the equipment. Class B devices have a Federal Communications

More information

ODOT ITB 063-14 Section 4: Flashers, Timers, & Software Systems Item 4-1

ODOT ITB 063-14 Section 4: Flashers, Timers, & Software Systems Item 4-1 ODOT ITB 063-14 Item 4-1 DATA SHEET SSF-86-3 ODOT ITB 063-14 Item 4-1 Solid State Flasher: Description: The PDC model SSF-86 solid state flasher is a dual circuit flasher designed for the Traffic Control

More information

AC-115 Compact Networked Single Door Controller. Installation and User Manual

AC-115 Compact Networked Single Door Controller. Installation and User Manual AC-115 Compact Networked Single Controller Installation and User Manual December 2007 Table of Contents Table of Contents 1. Introduction...5 1.1 Key Features... 6 1.2 Technical Specifications... 7 2.

More information

ScreenLogic Wireless Connection Kit. Installation Guide. pool/spa control system

ScreenLogic Wireless Connection Kit. Installation Guide. pool/spa control system pool/spa control system ScreenLogic Wireless Connection Kit Installation Guide P/N 520663 - Rev B 8 Technical Support Contact Technical Support at: Sanford, North Carolina (8 A.M. to 5 P.M.) Phone: (800)

More information

Control Panels D9412GV3/D7412GV3/D7212GV3. UL Installation Instructions

Control Panels D9412GV3/D7412GV3/D7212GV3. UL Installation Instructions Control Panels D9412GV3/D7412GV3/D7212GV3 en UL Installation Instructions Control Panels Table of Contents en 3 Table of Contents 1 Installation 4 1.1 Installation Preparation 4 1.2 Enclosure Options

More information

No Phone Line System. Quick Start Guide NPL II. 1.0 Installation

No Phone Line System. Quick Start Guide NPL II. 1.0 Installation Used in conjunction with EntraGuard Gold Telephone Entry Systems, the provides No Phone Line communication and door or gate control through existing building telephone lines without the need purchase phone

More information

SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL 1.1 SUMMARY A. This section describes the requirements for the installation of Power Monitors and associated

More information

************* OWNER'S MANUAL BAMF800/2 BAMF1250/2 BAMF1800/2 BAMF2200/2 BAMF2600/2 BAMF1200/4 BAMF1600/4 BAMF2000/1D BAMF4000/1D BAMF5500/1D

************* OWNER'S MANUAL BAMF800/2 BAMF1250/2 BAMF1800/2 BAMF2200/2 BAMF2600/2 BAMF1200/4 BAMF1600/4 BAMF2000/1D BAMF4000/1D BAMF5500/1D ************* OWNER'S MANUAL BAMF800/2 BAMF1250/2 BAMF1800/2 BAMF2200/2 BAMF2600/2 BAMF1200/4 BAMF1600/4 BAMF2000/1D BAMF4000/1D BAMF5500/1D INTRODUCTION Power Acoustik amplifiers provide high-performance

More information

Model #: SMART2200CRMXL

Model #: SMART2200CRMXL Tripp Lite 1111 West 35th Street Chicago, IL 60609 USA Telephone: +(773) 869 1234 E-mail: [email protected] Model #: SMART2200CRMXL SmartPro Compact Rackmount UPS System - Precision Protection for

More information

THE MclNTOSH MC 2100 SOLID STATE STEREO POWER AMPLIFIER

THE MclNTOSH MC 2100 SOLID STATE STEREO POWER AMPLIFIER THE MclNTOSH MC 2100 SOLID STATE STEREO POWER AMPLIFIER Price $1.25 Your MC 2100 stereo amplifier will give you many years of pleasant and satisfactory performance. If you have any questions concerning

More information

SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT

SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT FOR INTELLITOUCH AND EASYTOUCH CONTROL SYSTEMS INSTALLATION GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Technical

More information

Amplifier for Small Magnetic and Electric Wideband Receiving Antennas (model AAA-1B)

Amplifier for Small Magnetic and Electric Wideband Receiving Antennas (model AAA-1B) Amplifier for Small Magnetic and Electric Wideband Receiving Antennas (model AAA-1B) 1. Description and Specifications Contents 1.1 Description 1.2 1.2 Specifications 1.3 1.3 Tested parameters in production

More information

AN-6 COMMON MISTAKES IN LIGHTNING PROTECTION OF PHONE LINE INTERFACE CIRCUITS

AN-6 COMMON MISTAKES IN LIGHTNING PROTECTION OF PHONE LINE INTERFACE CIRCUITS AN-6 COMMON MISTAKES IN LIGHTNING PROTECTION OF PHONE LINE INTERFACE CIRCUITS By Joe Randolph Introduction Lightning protection of phone line interface circuits is a complicated topic. The specific protection

More information

49 Series - Relay interface modules 8-10 - 16 A. Features

49 Series - Relay interface modules 8-10 - 16 A. Features Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole

More information

Fundamentals of Power

Fundamentals of Power Fundamentals of Power Fundamentals of Power 2008 American Power Conversion Corporation. All rights reserved. All trademarks provided are the property of their respective owners. Learning Objectives At

More information

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS MAKING MODERN LIVING POSSIBLE AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS How to Use This Guide Read this Guide completely as you install and start up your new AK-SC 255 controller.

More information

Doc Ref: 2015.06.01.002. 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

Doc Ref: 2015.06.01.002. 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC TM 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC TM D400E Data Module (60Hz) The EDGE D400E is designed to meet high power density requirements for both the HPC and Web Scale environments while

More information

Installation and Operation Guide for PD4000 Series Power Control Center

Installation and Operation Guide for PD4000 Series Power Control Center Extended warranties are available for purchase at www.progressivedyn.com Installation and Operation Guide for PD4000 Series Power Control Center Member Thank you for selecting Progressive Dynamics as your

More information

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component. Overview Switch and button modules The dimensions of the switch and button modules are adapted to the electronic components in the integral housing. The modules are equipped with the universal clip-on

More information

BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS

BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS INTRODUCTION Rupture discs are often used as primary pressure relief devices and to isolate pressure relief valves. When used as a primary pressure relief

More information

DIRECT STRIKE PROTECTION. CAT Terminal, Gold, Model III

DIRECT STRIKE PROTECTION. CAT Terminal, Gold, Model III Lightning Protection International Pty Ltd Lightning Protection International Pty Ltd is a fully owned Australian manufacturer and supplier of direct strike lightning, surge and transient protection equipment

More information

Advantium 2 Plus Alarm

Advantium 2 Plus Alarm ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia

More information

T1 Backhaul Connectivity Solution All Products :: Application Note

T1 Backhaul Connectivity Solution All Products :: Application Note Telect 1 RU Customer Interface Panel (CIP) Enables Demarcation, Remote Circuit Maintenance and Trouble Isolation at the Backhaul Node The Application: T1 Demarcation and Testing in Backhaul Environments

More information

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors APPENDIX APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS RJ12 connectors Pin # 1 Signal Name Not Used 2 +TR Description + Data Line 3 +R Remote OFF Required or Remote OFF control 4 -TR 5 Not Used 6 RTN -

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 A Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical Relays

More information

Model CFA-24 Transparent Cable Farm Automation Switch

Model CFA-24 Transparent Cable Farm Automation Switch Model CFA-24 Transparent Cable Farm Automation Switch Ideal for Broadband Forum s ID-337 G.fast Certification and TR-249 VDSL2 Vectoring Testing High performance transparent solution designed to automate

More information

TAC1 Telephone Entry System Installation and Programming Manual

TAC1 Telephone Entry System Installation and Programming Manual TAC Telephone Entry System 4 7 3 6 8 9 Installation and Programming Manual The Chamberlain Group 84 Larch Ave. Elmhurst, IL 66-96 www.liftmaster.com TABLE OF CONTENTS SPECIFICATIONS 3 Cable Requirements

More information

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1 Power Supply Unit, Primary Switched, Narrow Design MINI POWER provides: Extra narrow design with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a wide-range input

More information