Baud rate: 9600 Data Bits: 8 Parity: Even Stop Bits: 1
|
|
|
- Paul Davis
- 9 years ago
- Views:
Transcription
1 Protocol of half-duplex system Baud rate: 9600 Data Bits: 8 Parity: Even Stop Bits: 1 (RS-232C/485): Communication Protocol: a) Computer send STX+ADD.Then startup strip screen to receive message.all of strip screen waiting for receive ADD after receving STX.They will going on if they received address accord with the range of themselves b) Computer send command. Strip screen run the right process or send and receive message after receving command. Computer going on send a series of data if necessary. Every frame(16 data validity at most) must end with ETX or ETB. The last frame end with ETX and other frames end with ETB. c) The strip screen return ACK after correct examination,otherwise return NACK and waiting for the computer Re-transmit. d) The format of next frame is SYN + Data Message + ETX(ETB) If last frame was received correctly and in order to be over continuedly.otherwise the strip screen finish receive data and makes data incomplete processing e) In any transmission waiting process, if the receiving side end standby period surpasses 3 seconds but has not received should to the information data, then does Overtime processing, the receiving end withdrawal receive and makes data incomplete processing. The sending side has not received anything or receives the wrong reply when waiting reply process the reply in 3 seconds, should attempt 3 time Re-transmits this frame data, if still has not received the reply or the accumulation receives 3 times of wrong replies, then produces the line fault prompt. f) Direction of transmission control: Principal and subordinate type software protocol,the host computer controls the way. Like uses 485 networks,all strip screen is at the receive condition when spare,and not control bus. While not connect the cable from half-duplex converter to host computer 232C mouth, the half-duplex switch 485 outputs also is at the receive condition, this time the main line does not have the equipment.need connect the terminal resistance. Transmission character description: 1.Control word: STX(0xCD): Start of Text ETX(0xAA+0xE6): End of Text ETB(0xE7): End Of Transmission Block SYN(0xCF): Synchronous Character ACK(0xF0): Acknowledge NACK(0x0F): Negative acknowledge 2.Address word: The strip screen address code is the BCD form,altogether 2 bytes,high bit in front,low bit in after,scope ,Each strip screen has an independent address,all strip 1
2 screen has a public broadcast address which is The most number of strip screen in one network is ADD (9,999):Broadcast address ADD (0-9998):Strip screen address, corresponding screen number Command word: Connect (0x00):Strip screen connection PowerOn (0x01): Open the strip screen PowerOff (0x02):Close the Strip screen ReadBMes (0x03):Reading the strip screen basic information ReadList (0x04):Reading listed files of the strip screen,according to numeral,small letter,capital letter order ReadPlay (0x05):Reading play lists of the strip screen ReadFile (0x06):Reading files of the strip screen StoreFile (0x07):Write a file to the strip screen ToTest (0x08):Download a file to carry on the test WritePlay (0x09):Writes play list to the strip screen SetPlayTime (0x0A):Setup information play time of the strip screen ToPlay (0x0B): Order programme one file of strip screen SetTime (0x0C):Setup time of strip screen EraseFile (0x0D):Delete one file of strip screen ClearSign (0x0E):Elimination strip screen memory Computer command and reply: 1.Strip screen connection test:stx+add+connect+etx Reply:*ACK:Connects successfully *NACK: Command to receive the mistake,re-transmit 2.Open the strip screen:stx+add+poweron+etx Reply:*ACK: Success,Screen could receive the new Command or the data after 3 seconds 3.Close the strip screen:stx+add+poweroff+etx Reply:*ACK:Success 4.Reading basic information of the strip screen:stx+add+readbmes+etx *Computer receive reply: *ACK:Success *Computer receive data:after receives ACK,The Computer prepares for receive the data Data format:stx+rtc+mes+ver+mm+yy+checksum+etx RTC:0x00 (has not installed),0x04 (has installed). MES:Currently filename of screen which moves ("0--9,A--Z,A--z"),0x00:Demo 2
3 information,0x04:test information VER: Version number of Strip screen Software,BCD form,like 10 expressions edition 1.0 MM+YY: production month,year of the Strip screen,bcd form CheckSum: sum of RTC+MES+VER+MM+YY examination,1 byte *Computer transmission reply:the Computer send ACK after examination each received data were accord with the requirement,otherwise send NACK and waiting Re-receives 5.Reading file list of strip screen::stx+add+readlist+etx *Computer receive reply:*ack:success. *NACK: Command to receive the mistake,re-transmit. * No reply:this screen has not connected to the network. *Computer receive data:after receive ACK,computer prepare for receive data. STX+ByteNum+FileName1+FileSize1+FileTime1+...+FileName(n)+FileSize(n) +FileTime(n)+CheckSum+ETB(ETX) ByteNum: The effective byte counting of this frame, Including filename, the size of the file, file play time. FileName:"0--9,A--Z,a--z". FileSize: The size of the file, regard byte as the unit. FileTime: The file play time, BCD form : Begin week (0 --6, 9 express and has not set for the time started ), Begin hour (0--23),Begin cent (0 --59),Finish week (0 --6, 9 express has not established and finish time), Finish hour(0--23),finish cent (0 --59). SYN+ByteNum+FileName(k)+FileSize(k)+FileTime(k)+... +CheckSum+ETB(ETX) *Computer receive reply: Send ACK after the computer measures all data received and fulfils requirements, otherwise send NACK and wait Re-transmit. 6. Read play list of the strip screen:stx+add+readplay+etx *Computer receive and reply::*ack:sucess. *Computer receive data: After receiving ACK, the computer prepares for receive the data. STX+ByteNum+FileName1+FileName2+...+FileName(n)+CheckSum+ETB(E TX) ByteNum: This effective byte of frame is counted. FileName:Filename"0--9,A--Z,a--z" SYN+ByteNum+FileName(k)+FileName(k+1)+...+CheckSum+ETB(ETX) 3
4 * Computer receive reply: Send ACK after the computer measures all data received and fulfils requirements, otherwise send NACK and wait Re-transmit. 7.Reading one file of strip screen::stx+add+readfile+filetype+filename+etx FileType: Type of the file, 0x00: Text file, 0x04: Figure file FileName: File name of the text "0--9,A--Z,a--z",File name of the Figure "A--Z" *Computer receive and reply: *ACK:sucess. *Computer receive data: After receiving ACK, the computer prepares for receive the data. STX+ByteNum+Data1+Data2+...+Data(n)+CheckSum+ETB(ETX) ByteNum: The effective byte counting of this frame. Data:data SYN+ByteNum+Data(k)+Data(k+1)+...+CheckSum+ETB( ETX) * Computer receive reply: Send ACK after the computer measures all data received and fulfils requirements, otherwise send NACK and wait Re-transmit. 8.Write information to one file of strip screen: STX+ADD+StoreFile+FileType+FileName+ETX * Computer receive reply: *ACK:Success * Computer send data: After receiving ACK, the computer prepares for send the data.. STX+ADD+ByteNum+Data1+Data2+...+Data(n)+CheckSum+ETB( ETX) ByteNum:The effective byte counting of this frame. Data:data SYN+ByteNum+Data(k)+Data(k+1)+...+CheckSum+ETB(ETX) * Send replying from the screen:send ACK after the screen measures all data received 9.Download information to screen for test:stx+add+totest+filetype+etx *Computer receive reply: *ACK:sucess. *Computer send data:after receiving ACK, the computer plan to send data. First frame form of the data:stx+add+bytenum+data1+data2+...+data(n)+checksum+etb(etx) 4
5 ByteNum:The effective byte counting of this frame. Data:data SYN+ByteNum+Data(k)+Data(k+1)+...+CheckSum+ETB(ETX) *Send replying from the screen:send ACK after the screen measures all data received 10.Write new play list to screen:stx+add+writeplay+etx *Computer receive reply: *ACK:sucess. *Computer send data:after receving ACK,the computer paln to send data. STX+ADD+ByteNum+FileName1+FileName2+...+FileName(n)+CheckSum+ETB (ETX) ByteNum:The effective byte counting of this frame. FileName:File name"0--9,a--z,a--z" SYN+ByteNum+FileName(k)+FileName(k+1)+...+CheckSum+ETB(ETX) *Send replying from the screen:send ACK after the screen measures all data received 11.Set play time of file to the screen:stx+add+setplaytime+etx *Computer receive reply: *ACK:sucess. *Computer send data:after receving ACK,the computer plan to send data. STX+ADD+ByteNum+FileName1+FileTime1+...+FileName(n)+FileTime(n)+Chec ksum+etb(etx) ByteNum:The effective byte counting of this frame, Including file name, the size of the file, the file broadcasts time. FileName:File name"0--9,a--z,a--z" FileTime:File paly time,,bcd form:the week at the beginning(0--6,9 express has not set for the time started),beginning hour (0--23),beginngin cent (0--59),finish week(0-- 6,9 express has not established finish time),finish hour(0--23),finish cent(0--59). SYN+ByteNum+FileName(k)++FileTime(k)+...+CheckSum+ETB(ETX) *Send replying from the screen:send ACK after the screen measures all data received 5
6 12. Order programme one file of strip screen:stx+add+toplay+filename+etx *Computer receive reply:*ack:sucess,do not show when the file name requested does not exist and return ACK. 13.Set time of screen (Only when RTC is installed): STX+ADD+SetTime+YY+MM+DD+DAY+HH+MM+TimeType+CheckSum+ETX TimeType:form of time(1--5). *Computer receive reply:*ack:sucess. 14.Delete one file of screen:stx+add+erasefile+filename+filetype+etx *Computer receive reply:*ack:sucess. 15.Clearn up the memory of screen:stx+add+clearsign+etx *Computer receive reply:*ack:sucess. Notice:* When information divides frames to convey, every frame information effective byte it counts to be very 16 most *The content of text information is ASCII code (include the special symbol), Model sign (0xFF,0x03,Model number), Speed sign (0xFF,0x02, speed number), Font sign(0xff,0x01,font number), Colour sign(0xff,0x00,colour sign), Image sign (0xFF,0x04,File name of Image), Time sign(0xff,0x05,time number), Colour number: 00:RED,01:LRD,02:GRN,03:LGN,04:AMB,05:BRN,06:ORG,07:YEL, 08:RB1, 09:RB2 Font number: 00:SS5,01:ST5,02:WD5,03:WS5,04:SS7,05:ST7,06:WD7,07:WS7 Speed number: 0x00--0x05 Model number: 00:HLD,01:FLS,02:WLUp,03:WLDown,04:WLLeft,05:WLRight,06: WLUnite,07:WLCleft,08:RLUp,09:RLDown,0A:RLLeft,0B:RLRight,0 C: RLUnite, 0D:RLCleft,0E:SPC,0F:SCR,10H:ROT,11H:CRT,12H:AUT 6
7 One text file include several above-mentioned form association, curtain of information, the largest length is 255 byteses. *The content of the information of the image is dot matrix, each point takes two byteses, the first express green, the second expresses red, 0x3F Showing the whole luminance, 0x36 expresses half a luminance, 0x30 express not show bright, the color is made up as follows: RED: 0x30,0x3F; LRD: 0x30,0x36; GRN: 0x3F,0x30; LGN: 0x36,0x30; AMB: 0x3F,0x3F; LGN: 0x36,0x36; ORG: 0x36,0x3F; YEL: 0x3F,0x36 transmitted from the first point of the first row to the last point of the last row. 7
How To Send A Message From A Computer To A Computer (Iwea) On A Microsoft Macbook 2.5 (Isoa) To A Microsatellite 2.4 (Ios) On An Unix (Ise
1. PROTOCOL ASTRA COMMUNICATION PROTOCOL (via RS232C) Argentina specification (B0319G) 26 Oct 2004 METHOD TRANSMISSION CONTROL PROCEDURE BAUD RATE DATA BIT STOP BIT PARITY DATA COMMUNCATION ORDER CONNECTOR
Technical Support Bulletin Nr.18 Modbus Tips
Technical Support Bulletin Nr.18 Modbus Tips Contents! Definitions! Implemented commands! Examples of commands or frames! Calculating the logical area! Reading a signed variable! Example of commands supported
NG360 Inclinometer with digital RS485 communications port and 360 degree measuring range
Inclinometer with digital RS485 communications port and 360 degree measuring range Features integrated 16bit microprocessor RS485 bus output signal no measuring range limitation 0.01 degree resolution
PROPERTY MANAGEMENT SYSTEM
PROPERTY MANAGEMENT SYSTEM COMMUNICATION INTERFACE SPECIFICATION NEC America, Inc. NDA-305-00 Revision.0 June, 998 Stock # 24727 LIABILITY DISCLAIMER NEC America reserves the right to change the specifications,
PRODUCT MANUAL SKX OPEN SKX ADVANCE ZN1RX-SKXOPEN. Edition 2 Version 1.1
PRODUCT MANUAL SKX OPEN SKX ADVANCE ZN1RX-SKXOPEN Edition 2 Version 1.1 INDEX 1. Introduction... 3 1.1. SKX Interface... 3 1.2. SKX Installation... 5 1.3. SKX Advance: Application Program... 5 1.3.1. SKX
Applied Data Communication Lecture 14
Applied Data Communication Lecture 14 Character oriented Data Link Character-oriented data link control Asynchronous Synchronous Kristjan Sillmann reaalajasüsteemide õppetool TTÜ automaatikainstituut character-oriented
Brunata Optuna W (171)
Brunata Optuna W (171) Communication description Edition 1.1 UK-QB101414 / 26.02.2013 Brunata a/s is a Danish owned company. We have more than 90 years of experience within developing and producing meters,
Operating Systems and Computer Networks / Datenverarbeitung 2 / Data Processing 2
Computer Networks / Datenverarbeitung 2 / Data Processing 2 Exercise 7: Network Transmission & Code Efficiency Faculty of Question 7.1 Code Efficiency Block Length S S S Y Y O N N H 5 characters S T X
LOCAL INTERCONNECT NETWORK (LIN)
54B-1 GROUP 54B LOCAL INTERCONNECT NETWORK (LIN) CONTENTS GENERAL INFORMATION........ 54B-2............ 54B-3 STRUCTURE................... 54B-2 54B-2 LIN refers to "Local Interconnect Network," which
Keep it Simple Timing
Keep it Simple Timing Support... 1 Introduction... 2 Turn On and Go... 3 Start Clock for Orienteering... 3 Pre Start Clock for Orienteering... 3 Real Time / Finish Clock... 3 Timer Clock... 4 Configuring
DSP801 Operation Manual
DSP801 Operation Manual 1. Information 2. Introduction 3. Installation 4. Pin Assignment 5. Character Tables 6. Software Control (Command List) 7. Specifications 8. Instruction of Demo Software Contents
Modbus Communications for PanelView Terminals
User Guide Modbus Communications for PanelView Terminals Introduction This document describes how to connect and configure communications for the Modbus versions of the PanelView terminals. This document
Process Control and Automation using Modbus Protocol
Process Control and Automation using Modbus Protocol Modbus is the fundamental network protocol used in most industrial applications today. It is universal, open and an easy to use protocol. Modbus has
MTS Master Custom Communications Protocol APPLICATION NOTES
MTS Master Custom Communications Protocol APPLICATION NOTES Rev. 0 12/6/94 Contents INTRODUCTION... 1 ACCOL TERMINAL ASSIGNMENTS... 1 MTS PROTOCOL SIGNAL LIST... 2 COMMUNICATIONS INTERFACE... 3 Line Parameter
plc numbers - 13.1 Encoded values; BCD and ASCII Error detection; parity, gray code and checksums
plc numbers - 3. Topics: Number bases; binary, octal, decimal, hexadecimal Binary calculations; s compliments, addition, subtraction and Boolean operations Encoded values; BCD and ASCII Error detection;
Serial Communications
Serial Communications 1 Serial Communication Introduction Serial communication buses Asynchronous and synchronous communication UART block diagram UART clock requirements Programming the UARTs Operation
Communicating with a Barco projector over network. Technical note
Communicating with a Barco projector over network Technical note MED20080612/00 12/06/2008 Barco nv Media & Entertainment Division Noordlaan 5, B-8520 Kuurne Phone: +32 56.36.89.70 Fax: +32 56.36.883.86
2. Terminal arrangement. Default (PV display) (SV display) Communication protocol selection Selects the Communication protocol. Modbus ASCII mode:
COMMUNICATION INSTRUCTION MANUAL TEMPERATURE CONTROLLER KT4, KT8 and KT9 No.KTC1E6 2009.05 To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual.
ESPA 4.4.4 Nov 1984 PROPOSAL FOR SERIAL DATA INTERFACE FOR PAGING EQUIPMENT CONTENTS 1. INTRODUCTION 2. CHARACTER DESCRIPTION
PROPOSAL FOR SERIAL DATA INTERFACE FOR PAGING EQUIPMENT CONTENTS 1. INTRODUCTION 2. CHARACTER DESCRIPTION 2.1 CHARACTER STRUCTURE 2.2 THE CHARACTER SET 2.3 CONTROL CHARACTERS 2.3.1 Transmission control
HOST Embedded System. SLAVE EasyMDB interface. Reference Manual EasyMDB RS232-TTL. 1 Introduction
Reference Manual EasyMDB RS232-TTL 1 Introduction This document explains how to use the interface EasyMDB RS232-TTL and describe the connections and the necessary commands for communicating with Cash System
RFID MODULE Mifare Reader / Writer SL025B User Manual Version 1.4 Nov 2012 StrongLink
RFID MODULE Mifare Reader / Writer User Manual Version 1.4 Nov 2012 StrongLink CONTENT 1. MAIN FEATURES... 3 2. PINNING INFORMATION... 4 3. BAUD RATE SETTING... 5 4. COMMUNICATION PROTOCOL... 5 4-1. COMMUNICATION
SPA-Bus Communication Protocol V2.5. Technical description
EN Issued 96-01-23 Modified 2001.07.31 Version C Checked MP Approved TK SPA-bus Communication Protocol V2.5 Data subject to change without notice Contents 1.0 Introduction... 4 2.0 General description...
Serial Communications / Protocol in AirTest Products
Serial Communications / Protocol in AirTest Products General The standard sensor has two different ways of serial communication with sensor s peripherals and the outside world. One is through the UART
ND48-RS ASCII A2.04 Communication Protocol
ND48-RS ASCII A2.04 Communication Protocol SEM 06.2003 Str. 1/6 ND48-RS ASCII A2.04 Communication Protocol ASCII A2.04 protocol provides serial communication with most of the measurement and control devices
Temp. & humidity Transmitter Instructions
Temp. & humidity Transmitter Instructions AQ3485/AQ3485Y www.aosong.com 1 Product Overview AQ3485/ AQ3485Y outdoor network temperature and humidity transmitter is accurate measurement of relative humidity
SERIAL INTERFACE. Series SSW-03 and 04
SERIAL INTERFACE Series SSW-03 and 04 SERIAL COMMUNICATION MANUAL SSW-03 and 04 CODE 0899.4457 E/2 MANUAL OF THE SERIAL COMMUNICATION SSW-03 and 04 Series: SSW-03 and 04 Software: Version 4.XX 0899.4657
2011, The McGraw-Hill Companies, Inc. Chapter 3
Chapter 3 3.1 Decimal System The radix or base of a number system determines the total number of different symbols or digits used by that system. The decimal system has a base of 10 with the digits 0 through
PRT3 Printer Module: ASCII Protocol Programming Instructions
PRT3 Printer Module: ASCII Protocol Programming Instructions We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com and send
Appendix B RCS11 Remote Communications
Appendix B RCS11 Remote Communications B.1 Host Computer Remote Communications Control and status messages are conveyed between the RCS11 and the host computer using packetized message blocks in accordance
Written examination in Computer Networks
Written examination in Computer Networks February 14th 2014 Last name: First name: Student number: Provide on all sheets (including the cover sheet) your last name, rst name and student number. Use the
CAM-VGA100 User Manual
CAM-VGA100 User Manual Release Note: 1. Jan 28, 2004 official released v1.0 2. Feb 24, 2004 official released v1.1 Fix the definition of verify code Fix the bug of unable jump to power save mode Fix the
Hagenberg Linz Steyr Wels. API Application Programming Interface
Hagenberg Linz Steyr Wels API Application Programming Interface Version 1.1 October 2015 FH OÖ Forschungs & Entwicklungs GmbH Franz-Fritsch-Strasse 11 / Top 3 4600 Wels Austria Research Center Hagenberg
E-i. Section E. Code Formatting. E/D = Enable/Disable T/DNT = Transmit/Do Not Transmit EX/DNEX = Expand/Do Not Expand
Section E Code Formatting E/D = Enable/Disable T/DNT = Transmit/Do Not Transmit EX/DNEX = Expand/Do Not Expand C/DNC = Convert/Do Not Convert E/DNE = Enable/Do Not Enable T/DNT UPC-A Check Digit (E - 1)
Plain-paper digital Fax/Copier/Printer/Scanner Scanner and Fax Guide
Plain-paper digital Fax/Copier/Printer/Scanner Scanner and Fax Guide Please read this guide before operating this machine. After you finish reading this guide, keep it handy for easy reference. Chapter
7.7 Ethernet Communication (AFPX-COM5)
7.7 Ethernet Communication (AFPX-COM5) 7.7.1 AFPX-COM5 Overview The communication cassette AFPX-COM5 has an Ethernet interface at the COM1 port and a 3-wire RS232C interface at the COM2 port. The Ethernet
Software Manual RS232 Laser Merge Module. Document # SU-256521-09 Rev A
Laser Merge Module Document # SU-256521-09 Rev A The information presented in this document is proprietary to Spectral Applied Research Inc. and cannot be used for any purpose other than that for which
Single channel data transceiver module WIZ2-434
Single channel data transceiver module WIZ2-434 Available models: WIZ2-434-RS: data input by RS232 (±12V) logic, 9-15V supply WIZ2-434-RSB: same as above, but in a plastic shell. The WIZ2-434-x modules
Contents. Preparation/SetUp...2
LAN Control Utility User Manual (for MH850U) Contents Preparation/SetUp... Preparation before using the network function... Connection...3 Installation...3 Setting the IP address of the projector...5 When
Using HyperTerminal with Agilent General Purpose Instruments
Using HyperTerminal with Agilent General Purpose Instruments Windows HyperTerminal can be used to program most General Purpose Instruments (not the 531xx series counters) using the RS-232 Serial Bus. Instrument
Industrial Networks & Databases
Industrial Networks & Databases - Device Bus - - Field Bus - - Data Bus - Recall An Industrial Communication Network (control network) - any group of devices (computers, controllers, meters etc.) working
1.Eastron SDM220Modbus Smart Meter Modbus Protocol Implementation V1.0
1.Eastron SDM220Modbus Smart Meter Modbus Protocol Implementation V1.0 1.1 Modbus Protocol Overview This section provides basic information for interfacing the Eastron Smart meter to a Modbus Protocol
LIN (Local Interconnect Network):
LIN (Local Interconnect Network): History: LIN (Local Interconnect Network) was developed as cost-effective alternate to CAN protocol. In 1998 a group of companies including Volvo, Motorola, Audi, BMW,
RN-XV-RD2 Evaluation Board
RN-XV-RD2 Evaluation Board 2012 Roving Networks. All rights reserved. -1.01Version 1.0 9/28/2012 USER MANUAL OVERVIEW This document describes the hardware and software setup for Roving Networks RN-XV-RD2
Card Issuing Machine for Magnetic, Contact & IC Card
9100-0020 SPECIFICATION M 1 OF 68 2007. 07. 28. Card Issuing Machine for Magnetic, Contact & IC Card KYTronics Corp.,Ltd 3 rd Floor, A-Dong, Twin Town-Bldg, 703-2. Gojan-Dong, AnSan-City, Kyung Ki-Do,
VisorALARM-Manager Application Quick Guide. (Ver. 1.3) Dm 380-I. V:3.0
VisorALARM-Manager Application Quick Guide. (Ver. 1.3) Dm 380-I. V:3.0 1. Installation Requirements 1.1. PC Pentium III processor or higher. Minimum RAM memory: 128 Mbytes Operating system: Windows XP
Nokia and Nokia Connecting People are registered trademarks of Nokia Corporation
Nokia and Nokia Connecting People are registered trademarks of Nokia Corporation Nokia E70 Configuring connection settings Nokia E70 Configuring connection settings Legal Notice Copyright Nokia 2006. All
ASCII Code. Numerous codes were invented, including Émile Baudot's code (known as Baudot
ASCII Code Data coding Morse code was the first code used for long-distance communication. Samuel F.B. Morse invented it in 1844. This code is made up of dots and dashes (a sort of binary code). It was
Software User Guide UG-461
Software User Guide UG-461 One Technology Way P.O. Box 9106 Norwood, MA 02062-9106, U.S.A. Tel: 781.329.4700 Fax: 781.461.3113 www.analog.com ezlinx icoupler Isolated Interface Development Environment
Development Kit EM4095 User s Manual
EM MICROELECTRONIC - MARIN SA Appte 405 Title: Product Family: Application te 405 Development Kit EM4095 User s Manual RFID Part Number: EMDB40 Keywords: RFID Design Tools Date: 5 September 00 TABLE OF
IP Surveillance TroubleShooting Guide Version: 0.9 Release: 20060527
IP Surveillance TroubleShooting Guide Version: 0.9 Release: 20060527 Chapter. 1. Introduction ACTi provides you a series of guides for your project from proposal stage to maintenance stage. They work
Control Technology Corporation CTC Monitor User Guide Doc. No. MAN-1030A Copyright 2001 Control Technology Corporation All Rights Reserved Printed in USA The information in this document is subject to
Programming Flash Microcontrollers through the Controller Area Network (CAN) Interface
Programming Flash Microcontrollers through the Controller Area Network (CAN) Interface Application te Programming Flash Microcontrollers through the Controller Area Network (CAN) Interface Abstract This
The I2C Bus. NXP Semiconductors: UM10204 I2C-bus specification and user manual. 14.10.2010 HAW - Arduino 1
The I2C Bus Introduction The I2C-bus is a de facto world standard that is now implemented in over 1000 different ICs manufactured by more than 50 companies. Additionally, the versatile I2C-bus is used
Features Reference. About Unified Communication System. Before Using This Machine. Starting a Meeting. What You Can Do During the Meeting
Features Reference About Unified Communication System Before Using This Machine Starting a Meeting What You Can Do During the Meeting Leaving a Meeting Managing Address Book Changing Network Configuration
Below is a diagram explaining the data packet and the timing related to the mouse clock while receiving a byte from the PS-2 mouse:
PS-2 Mouse: The Protocol: For out mini project we designed a serial port transmitter receiver, which uses the Baud rate protocol. The PS-2 port is similar to the serial port (performs the function of transmitting
Scanner Configuration
Scanner Configuration SmartScan Manual DOC Version 2.21 This document is specifically designed for the user to print two pages per sheet of paper with optimal print quality. Copyright 2005~ 2008 CIPHERLAB
OPERATOR INTERFACE PRODUCTS APPLICATION NOTE. Xycom 4800/2000 OIL (Operator Interface Language)- Series Terminals: Backup and Restore with ProComm
Page 1 of 9 Xycom 4800/2000 OIL (Operator Interface Language)- Series Terminals: Backup and Restore with ProComm Introduction The Xycom 4800/2000 OIL-series terminals offer you the ability to backup and
Local Interconnect Network Training. Local Interconnect Network Training. Overview
Overview Local Interconnect Network Training History and introduction Technical features The ISO/OSI reference model and LIN Frames Message Frames Communication concept of LIN Command Frames and Extended
The string of digits 101101 in the binary number system represents the quantity
Data Representation Section 3.1 Data Types Registers contain either data or control information Control information is a bit or group of bits used to specify the sequence of command signals needed for
Signalling Control System Serial Train Information Interface
Specification Signalling Control System Serial Train Information Interface Issued Date: 04 April 2014 Important Warning This document is one of a set of standards developed solely and specifically for
BARCODE READER V 2.1 EN USER MANUAL
BARCODE READER V 2.1 EN USER MANUAL INSTALLATION OF YOUR DEVICE PS-2 Connection RS-232 Connection (need 5Volts power supply) 1 INSTALLATION OF YOUR DEVICE USB Connection 2 USING THIS MANUAL TO SETUP YOUR
ENET-710. ENET-710 - Ethernet Module ENET-710 JAN / 06 FOUNDATION
ENET-710 ENET-710 - Ethernet Module JAN / 06 ENET-710 FOUNDATION E N E T 7 1 0 ME smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is
PM1122 INT DIGITAL INTERFACE REMOTE
PM1122 INT DIGITAL INTERFACE REMOTE PM1122 INT front panel description: 1. Clear wireless remotes knob: push this button for more than 2 seconds to clear the list of all assigned wireless remote settings
Dolphin In-Circuit programming Updating Firmware in the field
Dolphin In-Circuit programming Updating Firmware in the field 1 Introduction In systems e.g. gateways, where an external microcontroller is connected to a Dolphin based product like a TCM300 it might be
USB Card Reader Configuration Utility. User Manual. Draft!
USB Card Reader Configuration Utility User Manual Draft! SB Research 2009 The Configuration Utility for USB card reader family: Concept: To allow for field programming of the USB card readers a configuration
You can search the event by POS and you can also add the Time Search condition to narrow the search range. By
POS Event Search: You can search the event by POS and you can also add the Time Search condition to narrow the search range. By marking the various POS conditions, you can decide the search range. DVR
1. Introduction... 3 Introduction...2. 4. Deal command... 13
Dealer4 PC Software User Manual Service Software Manual ver:ver: 1.11.2 1. Introduction... 3 Introduction...2 2.1 Main Menu... 4 2.1. Main Menu window...4 Summary of additional functions...3 2.2. Board
Bill Redirect Software How To Schedule Tasks in Bill Redirect
Bill Redirect Software How To Schedule Tasks in Bill Redirect Supported Operating Systems: Windows 98,Me,2000,3000,XP,NT4, Vista. This tutorial shows how you can schedule a command/action in Bill Redirect
RFID MODULE Mifare Reader / Writer SL032 User Manual Version 1.5 Nov 2012 StrongLink
RFID MODULE Mifare Reader / Writer User Manual Version 1.5 Nov 2012 StrongLink CONTENT 1. MAIN FEATURES... 3 2. PINNING INFORMATION... 4 3. BAUD RATE SETTING... 5 4. COMMUNICATION PROTOCOL... 5 4-1. Communication
Data Link Layer(1) Principal service: Transferring data from the network layer of the source machine to the one of the destination machine
Data Link Layer(1) Principal service: Transferring data from the network layer of the source machine to the one of the destination machine Virtual communication versus actual communication: Specific functions
HYUNDAI Fingercam. User Manual
HYUNDAI Fingercam User Manual 7 1. Structure Detail I Characters of Product 8 It has small contour design, which does UV spray finishing for the whole body. Itisvery fashionable and wearable and matches
Controlling the projector using a personal computer
DLP Projector XD520U/XD510U/XD500U/SD510U/EX51U/XD500U-ST XD520U-G/XD510U-G/XD500U-G Controlling using a personal computer This projector can be controlled by connecting a personal computer with RS-232C
Voyager 9520/40 Voyager GS9590 Eclipse 5145
Voyager 9520/40 Voyager GS9590 Eclipse 5145 Quick Start Guide Aller à www.honeywellaidc.com pour le français. Vai a www.honeywellaidc.com per l'italiano. Gehe zu www.honeywellaidc.com für Deutsch. Ir a
Operating Instructions Serial Monitor 4040. ROBERT RIELE GmbH & Co KG
Operating Instructions Serial Monitor 4040 ROBERT RIELE GmbH & Co KG Software Version 1.0 Documentation Version 05.2005 1 Introduction to Serial Monitor 4040 The software Serial Monitor 4040 was developed
ARM Thumb Microcontrollers. Application Note. Software ISO 7816 I/O Line Implementation. Features. Introduction
Software ISO 7816 I/O Line Implementation Features ISO 7816-3 compliant (direct convention) Byte reception and transmission with parity check Retransmission on error detection Automatic reception at the
CONCEPT1 RS232 COMMUNICATION
Concept 1 RS-232 Communication Communication with Concept 1 via RS-232 is done with simple ASCII Commands and Replies. The port settings are 19200Baud, 8bits, no parity and 1 stop bit. The physical connection
L1255-4149 Firmware And FPGA Configuration Upgrade
Technical Note TN133 Issue:2 L1255-4149 Firmware And FPGA Configuration Upgrade IMPORTANT NOTE: When using USB to Serial converters and upgrading the Firmware there is a danger of early L1255s becoming
Push button 3gang standard flush-mounted 751633xx
Documentation Product name: Push button 3gang standard Design: device (up) ETS search path: Push button / Push button 3gang / Push button 3gang standard Functional description: The push button 3gang standard
Modbus Protocol. PDF format version of the MODBUS Protocol. http://www.http://www.modicon.com/techpubs/toc7.html. The original was found at:
Modbus Protocol PDF format version of the MODBUS Protocol The original was found at: http://www.http://www.modicon.com/techpubs/toc7.html (In case of any discrepancies, that version should be considered
Index...1. Introduction...3. Installation- Keyboard Wedge...3 RS-232...3 USB...3. Default Setting for each barcode shown as below:...
Index Index...1 Introduction...3 Installation- Keyboard Wedge...3 RS-232...3 USB...3 Default Setting for each barcode shown as below:...4 Programming the MS320...5 Interface Selection...7 Keyboard wedge...8
The Answer to the 14 Most Frequently Asked Modbus Questions
Modbus Frequently Asked Questions WP-34-REV0-0609-1/7 The Answer to the 14 Most Frequently Asked Modbus Questions Exactly what is Modbus? Modbus is an open serial communications protocol widely used in
TruePort Windows 2000/Server 2003/XP User Guide Chapter
TruePort Windows 2000/Server 2003/XP User Guide Chapter 0 This document provides the procedure for installing and using TruePort on Windows 2000/Server 2003/XP. Table of Contents What is TruePort?...3
Memory is implemented as an array of electronic switches
Memory Structure Memory is implemented as an array of electronic switches Each switch can be in one of two states 0 or 1, on or off, true or false, purple or gold, sitting or standing BInary digits (bits)
ACCESS 9340 and 9360 Meter Ethernet Communications Card 9340-60-ETHER
User s Guide PMCM-ETHCC-0208 2/2008 ACCESS 9340 and 9360 Meter Ethernet Communications Card 9340-60-ETHER TABLE OF CONTENTS INTRODUCTION... 2 Supported Ethernet Protocols... 2 Hardware... 2 Meter Firmware...
4511 MODBUS RTU. Configuration Manual. HART transparent driver. No. 9107MCM100(1328)
4511 MODBUS RTU Configuration Manual HART transparent driver No. 9107MCM100(1328) 9107 CONTENTS Introduction... 3 Modbus basics... 3 Modbus RTU... 3 Supported Function Codes... 3 Modbus Parameters and
BenchMark 460 Marking System
BenchMark460 Marking System General Arrangement Drawing SYSTEM OVERVIEW The Telesis BenchMark 460 marking system permanently prints messages into a variety of materials such as steel, aluminum, and plastic.
SMS based remote control system
EE 318 Electronics Design Project Report, EE Department, IIT Bombay, April 2006 SMS based remote control system Ashish Deswal ( 03007020 ) Shaleen Harlalka ( 03007015 ) Arjun Arikeri ( 03007032 ) Ashish
Using the HCS12 Serial Monitor on Wytec Dragon-12 boards. Using Motorola s HCS12 Serial Monitor on Wytec s Dragon-12 boards
Using Motorola s HCS12 Serial Monitor on Wytec s Dragon-12 boards Wytec s Dragon-12 development boards are pre-installed with DBug-12, a small monitor program which allows a user to interact with the board
TICO-EN. TiXML-Console TICO. User Manual V1.4.0.8
TICO-EN TiXML-Console TICO User Manual V1.4.0.8 2008 Tixi.Com GmbH, Berlin Publication close: September 2008, v.1.4.0.8 This manual is protected by copyright. Any further sale is prohibited without the
EasyMP Monitor Operation Guide Ver.4.50
EasyMP Monitor Operation Guide Ver.4.50 Notations Used in This Guide The following table shows the symbols used in this manual, along with descriptions of what they mean. Attention s Indicates procedures
GPS NTP Time Server for Intranet Networks DIN RAIL Version
GPS NTP Time Server for Intranet Networks DIN RAIL Version Description: GPS NTP time server is very simple low cost solution for Ethernet / Intranet time synchronization. Each computer or devices with
Catalogue. Write Text Command (A command)...5. Write Variable Command (C command)...7. Write Graphics Command (E command)...8.
Chapter 1: Summarization Catalogue Moving Sign Communication Protocol V1.2 A. Summarization...2 B. or the display text....2 C. Serial communication setup....2 D. The text file display stipulation..2 E.
RFID MODULE Mifare Reader / Writer SL031 User Manual Version 2.7 Nov 2012 StrongLink
RFID MODULE Mifare Reader / Writer User Manual Version 2.7 Nov 2012 StrongLink CONTENT 1. MAIN FEATURES... 3 2. PINNING INFORMATION... 4 3. BAUD RATE SETTING... 5 4. COMMUNICATION PROTOCOL... 5 4-1. Communication
x10* CP290 HOME CONTROL INTERFACE PROGRAMMING GUIDE FOR ADVANCED PROGRAMMERS
x10* CP290 HOME CONTROL INTERFACE PROGRAMMING GUIDE FOR ADVANCED PROGRAMMERS 1 TABLE OF CONTENTS 3. Introduction. 6. Programming. 7. RS-232 connections. a. Byte format. 9. Download Base Housecode. IO.
OfficeServ Link. User Guide. Version 2.1 June 2005
OfficeServ Link User Guide Version 2.1 June 2005 OfficeServ Link Version 2.1 User Guide This manual should be read before the installation and operation of the OfficeServ Link Software. COPYRIGHT This
Stop And Wait. ACK received; transmit frame 2 CS 455 3
Data Link Layer, Part 5 Sliding Window Protocols These slides are created by Dr. Yih Huang of George Mason University. Students registered in Dr. Huang's courses at GMU can make a single machine-readable
Customer Pole Display SERIES 8035 Operation Manuanl. Version 1.1
Customer Pole Display SERIES 8035 Operation Manuanl Version 1.1 This equipment has been tested and found to comply with the limits for Class A digital device. Pursuant to Part 15 of the FCC Rules. These
APR-PRT3 Printer Module: C-Bus Programming Instructions
APR-PRT3 Printer Module: C-Bus Programming Instructions We hope this product performs to your complete satisfaction. Should you have any questions or comments, please visit www.paradox.com and send us
Master-Touch and ValuMass. Modbus Communications. INSTRUCTION MANUAL 80202201 (Rev. 2.1)
Master-Touch and ValuMass Modbus Communications INSTRUCTION MANUAL 80202201 (Rev. 2.1) Eldridge Products, Inc. 2700 Garden Road, Building A Monterey, CA 93940 Tel: 800/321-3569 or 831/648-7777 Fax: 831/648-7780
hp ProLiant network adapter teaming
hp networking june 2003 hp ProLiant network adapter teaming technical white paper table of contents introduction 2 executive summary 2 overview of network addressing 2 layer 2 vs. layer 3 addressing 2
