1 APPLIED INDUSTRIAL ENERGY AND ENVIRONMENTAL MANAGEMENT Z. K. Morvay, D. D. Gvozdenac Part III: FUNDAMENTALS FOR ANALYSIS AND CALCULATION OF ENERGY AND ENVIRONMENTAL PERFORMANCE Applied Industrial Energy and Environmental Management Zoran K. Morvay and Dusan D. Gvozdenac John Wiley & Sons, Ltd Toolbox 2 Step-By-Step Guide to Carrying Out an Energy Audit STEP 1 STEP 2 STEP 3 STEP 4 STEP 4.1 STEP 4.2 UNDERSTANDING INDUSTRIAL OPERATIONS PRELIMINARY ENERGY AUDIT IDENTIFICATION OF ENERGY CONSERVATION OPPORTUNITIES (ECO) DETAILED ENERGY AUDIT (DEA) preparing measurement plans and conducting measurements SPECIFICATION OF ENERGY CONSERVATION MEASURES (ECM) PREPARATION AND PRESENTATION OF DEA REPORT AND ACTION PLANS STEP 1: UNDERSTANDING INDUSTRIAL OPERATIONS Developing an understanding of industrial operations is a prerequisite for the analysis of energy efficiency in an organization. In order to achieve that, we start with data on the general characteristics of the business (Checklist 1) followed by data collection on energy use, main utilities and characteristics of energy end-use requirements, as described by Step 2. CHECKLIST 1: GENERAL CHARACTERISTICS Activity Type (sector): Main products: Production capacity [t/y] Capacity utilization [%] NATIONAL OR MULTINATIONAL: History When established: Growth pattern 1
2 2 Cost structure Raw material [%] Labor [%] Energy [%] Other [%] EXTERNAL ENVIRONMENTAL FACTORS Economics Broad economic setting: Development trends: Structure and share of the market: OBJECTIVES AND STRATEGIES General Specific organizational objectives and strategies as defined by management Growth Growth objectives over the next 5 years Investment Policies and plans, main projects STEP 2: PRELIMINARY ENERGY AUDIT (PEA) A PEA is essentially a data gathering exercise which aims to develop an understanding of how energy is used in a factory, and prepare a background for detailed energy audit (DEA) implementation (Fig. 2.1). Questionnaires 1 and 2 will help to guide you through and structure the data gathering process.
3 3 QUESTIONNAIRE 1: Figure 2.1: Flow Chart of Preliminary Energy Audit (PEA) PRELIMINARY ENERGY AUDIT Data on energy consumption and costs Company: Address: General Manager: Contact person: Telephone, Fax, By: Date:
4 4 GENERAL INFORMATION Production program and capacity Production in the year (description and quantities of final products) 1 Raw materials (description and quantities): Short process description (phases) Draft scheme of the production process 1 All quantities shall be given for the same year.
5 5 Electricity, V Steam, 8 barg Industrial Water Cooling Water, 34 o C Compressed Air, 7 barg Waste Water Solid Waste Total annual operating time [h/yr]: Number of shifts per working day: Total number of employees: Number of employees in energy group: Head of group: Total annual cost of production: Total annual cost for energy and water:
6 6 Layout of the factory
7 7 MONTHLY SUMMARY OF FUEL OIL CONSUMPTION AND COSTS Name of fuel: Source: Fuel classification: Average low calorific value [kj/kg]: Year of consumption: Month Deliveries [l] Cost of delivery [ ] Working days in a month Consumption [l] Cost of consumed fuel [ ] I II III IV V VI VII VIII IX X XI XII Total
8 8 MONTHLY SUMMARY OF ELECTRICITY ENERGY AND COSTS Tariff description: Year of consumption Total cost Active energy Reactive energy [ ] Month Consumption Price/unit Consumption Price/unit [kwh] [ /kwh] [kvarh] [ /kvarh] I II III IV V VI VII VIII IX X XI XII Total
9 9 MONTHLY SUMMARY OF ELECTRICITY DEMAND COSTS Month Maximum demand (on peak; partial peak) On peak [kw] Partial peak [kw] On peak Cost [ ] Partial peak Total cost of demand Total cost of energy and maximum demand [ ] [ ] I II III IV V VI VII VIII IX X XI XII Total MONTHLY SUMMARY OF FRESH WATER CONSUMPTION AND COSTS Year of consumption District system Own wells Month Consumption Price/unit Cost Consumption Price/unit Cost [l] [ /l] [ ] [l] [ /l] [ ] I II III IV V VI VII VIII IX X XI XII Total
10 10 MONTHLY SUMMARY OF WASTE WATER COSTS Year of consumption Total cost of Sewerage system Total cost water Month Consumption Price/unit Cost [l] [ / ] [ ] [ ] [ ] I II III IV V VI VII VIII IX X XI XII Total
11 11 QUESTIONNAIRE 2: PRELIMINARY ENERGY AUDIT Specifications of main utilities ENERGY TRANSFORMERS Boiler Room STEAM to process BOILER No.1 BOILER No.2 Feed Water Pumps Blow Down Make Up Water Oil Preheater Heavy Fuel Oil FEED WATER TANK EXAMPLE Return condensate app. 65 % Figure 2.2: Draft Scheme of the Boiler Room Number of boilers: Total capacity: Total annual production of heat energy [TJ/yr]: Total annual fuel consumption [h/yr]: Total annual operating time [h/yr]: Total annual quantities of water supplied to the system [h/yr]:
12 12 Steam Boiler Figure 2.3: Draft Scheme of the Steam Boiler Type of boiler: Design capacity [t/h]: Fuel: Total annual operating time [h/yr]: Age [years]: Rated capacity [t/h]: Annual fuel consumption [yr]: Annual operating period: Pressures and Temperatures Steam pressure at boiler outlet [kpa] Steam temperature at boiler outlet [ o C]: Water temperature at boiler inlet [ o C]: Combustion air temperature [ o C]: Temperature of gas leaving the boiler [ o C]: Fuel temperature [ o C]: Flue Gas Analyses CO 2 : O 2 : CO: N 2 : Excess air:
13 13 Electric Power Figure 2.4: Draft Single-Pole Scheme of the Transformer Station s Connection Annual need for electric power satisfied by: Distribution system [%] Your own CHP plant [%] Voltage of the power supply system [kv] Voltage transformation [kv] Number of transformer stations Number of transformers Total installed capacity [kva] Installed capacity per units [kva] ENERGY END-USERS A/C systems A/C systems used: Number of independent systems: Total design quantity of the A/C air output [m 3 /h]
14 14 A B C D E OEF OEF AEF AEF m 3 /h m 3 /h m 3 /h m 3 /h PREMISES 24 o C 50 % PREMISES 24 o C 50 % PREMISES 24 o C 50 % PREMISES 24 o C 50 % PREMISES 24 o C m 3 /h 825 kw AHU SA RA m 3 /h 1943 kw AHU SA RA m 3 /h 605 kw AHU SA RA m 3 /h 170 kw AHU SA RA SA m 3 /h CFU FA m 3 /h FA m 3 /h FA 3150 m 3 /h FA m 3 /h 1512 kw OAHU 1 & m 3 /h 66 kw OAHU 3 OAHU 4 FRESH AIR FRESH AIR FRESH AIR FRESH AIR Figure 2.5: Draft Scheme of the System Age [years] Total design capacity of air cooling [MJ/s] Annual operating time (describe all relevant facts and characteristics, such as changes in working conditions, seasonal and other) Daily operating time (describe): Air temperature [ o C] Type of regulation
15 15 Compressed air system Compressed air system used in a building: 100A 100A CFU-1 40A AIR SUPPLY 50A/75A 200A 65A DOMNICK AO 15/ Pre Filter DRY-1 DC5600 AF0.9 After Filter Flow Adjust 65A 65A PQ 200A 150A /100A 20A 150A /100A Ball Valve 40A AIRSUPPLY 50A/75A 100A 10A 15A 100A 65A DOMNICK AO 15/ Pre Filter DRY-2 DC5600 AF0.9 After Filter Flow Adjust 65A 65A PQ 40A AIR SUPPLY 15A 75A 65A DOMNICK AO 15/ PreFilter DRY-3 DC5600 AF0.9 After Filter Flow Adjust 65A 65A PQ 40A AIRSUPPLY 15A 75A 100A 200A PreFilter 65A After Filter FQ 100A 100A 100A 40A AIR SUPPLY 15A 75A 200A PreFilter 65A 200A PreFilter 65A After Filter FQ After Filter FQ Unload 100A 20A 25A 25A 15A Air Tank WWT. Auto Tabe Cleaning R-3 200A PreFilter 65A After Filter FQ 40A 15A 10A Seperator SequenceControl in Control room 40A Unload 80A Pre Filter 50A DOMNICK 40/30/ DRY FQ After Filter PCC1200 AF Flow Adjust 80A 40A 50A Figure 2.6: Draft Scheme of the Compressed Air System Number of compressors: Total capacity [nm 3 /min] Capacity per unit [nm 3 /min] Output pressure [kpa] Total capacity of electric motors [kw] Unit capacity of electric motors: [KW] Volume of the tank [m 3 ] Type of regulation Air cooling system Parameters Working pressure of machinery [kpa] Entering air temperature [ o C] Daily operating time (system): Daily operating time (compressors):
16 16 STEP 3: IDENTIFICATION OF ENERGY CONSERVATION OPPORTUNITIES (ECOs) During inspection of the plant, as a part of PEA activities, opportunities for energy conservation have to be identified. The following checklist should serve as a reminder as to where to look for ECOs. Based on the ECOs identified, measurement plans will be prepared and measurements executed during the DEA, in order to evaluate the potential for energy performance improvement by individual ECOs. ELECTRICAL SYSTEM GENERAL Use demand limiters where applicable and where cost benefits exceed installed cost without creation of unacceptable environmental conditions or limitations in manufacturing production. Replace oversized motors and replace old motors with new energy-efficient motors. Investigate power factor improvement. Use two- or three- speed motors on pumps and fans when reduced flow is desired. Improve maintenance for all equipment. Reduce lighting levels where this will not reduce manufacturing production or quality or sales efficiency. Turn off lights when not needed. Replace present lighting with more efficient lighting sources. In manufacturing processes control warm-up time and turn off time. Reschedule production or other operations to spread out the electrical load and thus improve the load factor. When possible, modulate a load rather than turning it off and on. Install small electric boilers for local requirements rather than operating a complete steam system. In manufacturing plants, install sub metering for manufacturing sections. This has the effect of making a manufacturing subsection an energy profit centre. Use variable-speed drives. Installation of electrical-peak-shaving generators. The largest savings of electrical energy by electrical energy management will come from the basic principle: WHEN YOU DON'T NEED IT, TURN IT OFF AIR CONDITIONING Turn off air conditioning in all unoccupied areas. Ensure that the air conditioning system is in good working order; keep filters, coils and blowers clean. Use spot coolers when spaces are occupied only at various and irregular times. Clean refrigerant condensers to reduce compressor horse power. Utilize humidity controlling systems which will allow humidity to rise to the highest acceptable setting systems that use re-heat are particularly beneficial. Minimize the heat created by lights, machinery or equipment which are left on when not required. Leave storm doors and windows in place during the summer to prevent outside heat from coming in. Use water cooled lighting fixtures if possible. If the office is completely vacated after normal closing hours, turn off air conditioning at least one hour before quitting time.
17 17 If possible, use heat-producing equipment such as photocopiers in the early morning or late afternoon. Use awnings or shades to reduce heat gain from insulation. Urge employees to wear lighter clothing in order to accustom themselves to slightly higher office or plant temperatures. Consider a spraying system or other means of evaporating water on the roof in order to reduce the air conditioning load. Size air handling grills, ducts and coils in order to minimize air resistance. LIGHTING Turn off all unnecessary lights. Replace low efficiency light sources with fluorescent, mercury, sodium or high intensity direct lighting. Keep bulbs and fixtures clean and free of light-blocking dirt. Remove lights selectively and ballasts where lighting levels exceed established standards. Reduce or eliminate decorative lighting. Install photocells in order to control outdoor or perimeter lighting. Utilize direct sunlight as a light source wherever possible. Employ a lower wattage of lighting where possible. Use light colors on ceilings and walls, floors and furnishings. Install timers on lights in little used areas of the plant. Use automatic switches in order to ensure that plant lighting is extinguished after the last shift leaves. Provide light switches in office areas so that individual lights may be turned off. Place lighting switches in prominent places. Move to task lighting wherever possible. Eliminate inefficient electric lamps from plant stocks and catalogs. Consider turning off plant lights during lunch breaks. INDUSTRIAL BOILERS Look to stack gas temperatures as a running indicator of boiler performance. Carry out frequent checks of boiler performance. If more than one boiler is in use, sequence boiler use in decreasing order of efficiency. Keep as many boilers as possible operating near full load (rather than having a greater number operating at partial capacity). Keep all heat transfer surfaces clean. Improve boiler control systems. Reduce excess air in order to increase boiler efficiency. Look to waste heat boilers and/or economizers in order to utilize hot stack gases. Utilize boiler blow-down as flash steam or in a blow-down heat exchanger in order to preheat make-up water. Reduce blow-down through feed-water control. STEAM Fully insulate all steam and condensate lines, and process equipment. Cover and insulate condensate tanks. Repair or replace faulty steam traps. Repair all other sources of steam leakage including flanges and high pressure reducing stations. Maintain steam jets used for vacuum system. Ensure that boilers are operating at peak efficiency.
18 18 Keep boiler tube surfaces clean. Return condensate to boiler or use pre-softened cooling water from compressors, etc. as feed-water in order to minimize both blow-down and overall energy and water consumption. Monitor boiler blow-down chemical analysis. Recapture blow-down energy using heat exchangers or flash tanks. Use air heaters and/or economizers to recover heat from boiler flue gases. Minimize the distance that steam must travel by re-arranging process equipment and eliminating straggling steam laterals. Use insulation valves to split up the steam distribution system. Operate steam-heated processes at the lowest permissible temperature. Lower steam pressures wherever possible. Use steam traps and/or balance pressure air vents in order to eliminate air films in steam lines. Put flash steam to work in lower pressure applications. Where clean condensate cannot be returned to the boiler, use it for washing or other processes. Turn off steam tracing during mild weather. Look to glycol tracing systems to replace steam. Consider replacing electric motors with back pressure steam turbines and use exhaust steam for process heat. Operate distillation columns at minimum quality requirements. Operate distillation columns at near flooding conditions for maximum separation efficiency. Determine correct feed plate location on distillation columns in order to increase efficiency and minimize steam consumption. Consider switching selected steam stripping distillation units from direct (live) steam to indirect (dry) stripping. Use steam traps of a correct size. Evaluate replacing condensing steam turbine rotating equipment drives with electric motors, if your plant has a power generating capability. Add traps to distillation column in order to reduce the reflux ratio. Minimize boiler blow-down with better feed-water treatment. Use waste heat low pressure steam for absorption refrigeration. Replace barometric condensers with surface condensers. Shut off steam traps on superheated steam lines when not in use. Optimize the operation of multi-stage vacuum steam jets. Use insulation of optimum thickness. Use reflux ratio control or similar control instead of flow control on distillation towers. Substitute hot process fluids for steam. FURNACES, KILNS AND OVENS Calculate and plot boiler efficiency daily. Establish a definite burner maintenance schedule. Adjust burners regularly for the most efficient operation. Heat oil to a proper temperature for good atomization. Eliminate combustible gas in flue gas. Reduce combustion air flow to an optimum level. Replace obsolete burners with more efficient ones. Use waste and by-products as fuel wherever possible. Limit and control secondary combustion air in furnace operations. Calculate a heat balance for all combustion equipment in order to better understand where energy is dissipated or used. Utilize hot stack gases as an energy source. Insulate furnaces, kilns and ovens in order to minimize heat loss.
19 19 Control infiltration of cold air into furnaces. Shut down idle combustion whenever possible. Consider cam controllers or other systems in order to control the shut down cycle on combustion equipment. Schedule plant operations for full load operations on combustion equipment. Minimize energy loss during loading and unloading (cycling). Eliminate over-design in equipment and practices. Analyze flue gases regularly. Look into using automatically controlled flue dampers. COMPRESSED AIR Make an optimized selection of a central compressor versus a number of smaller zone compressors. Choose the compressor with the highest efficiency. Select an air intake location that provides dry, clean air. Maintain compressor driving belts, and all other critical parts. Ensure that water cooling ducts are not blocked. Use larger or extra receivers on existing compressors. Investigate automatic control systems. Provide basic instrumentation in order to gauge system efficiency. Repair all line leaks promptly as part of a regular maintenance program. Use long radius bend and welded joints wherever possible in piping. Incorporate strainers and lubricators in each air-operated device. Maintain air operated equipment regularly as well as conditioning units filters, pressure regulators and lubricators. Do not operate equipment above the manufacturer's recommended operating pressure. Reduce air pressure to the lowest feasible level. Consider using double acting air cylinders. Use hot air from remote receiver tanks close to cylical loads. Use hot air from air cooled compressors for space heating wherever economically available. Cooling water from water cooled compressors has many potential uses within the plant.
20 20 STEP 4: DETAILED ENERGY AUDIT (DEA) A detailed energy audit aims at establishing actual energy performance of selected end-users and processes. Based on identified of energy conservation opportunities during the preliminary audit. At the heart of a DEA is a specific metering campaign which usually takes a week or two according to a carefully prepared measurement plan (see Examples 1 and 2 below). The measuring results are analyzed in order to establish energy balances, specify performance improvement measures (Step 4.1) and carry out an economic and financial analysis of performance improvement projects (Fig. 2.7) Figure 2.7: Flow Chart of Detailed Energy Audit (DEA) The Economic and Financial Evaluation of energy performance improvement measures includes cost-benefit analysis, calculation of economic and financial internal rates of return (EIRR and FIRR) and a discounted cash flow analysis. It is described in Toolbox III-3 and includes a spreadsheet program (Software No. 3, Toolbox III-3), for carrying out such calculations. The audit results have to be summarized in a report, together with an action plan containing the priorities for the implementation of performance improvement projects, as specified in Step 4.2.
21 21 Example 1: Preparing the measurement plan for a steam boiler M1 M2 M3 M4 M5 M6 M7 Combustion air: - Temperature, t FA [ o C] - Relative humidity, RH FA [%] Fuel consumption: - Fuel flow rate, mf [l/h, t/h, nm 3 /h.] - Temperature, t F [oc] Steam (saturated): - Pressure, p S [bar] Feed water: - Mass flow rate of feed water, m FW [t/h] - Temperature, t FW [ o C] - Conductivity, Cond FW, [µs/cm] Flue gas: - Flue gas temperature, tfg [ o C] - Oxygen content, O 2 [%] - CO content, CO [ppm] Blow-down: - Mass flow rate of blow-down water, m BD, [t/h] Boiler water: - Conductivity, CondBW, [µs/cm] Example 2: Preparing measurement plan for a a Sterilization Process (Retorts) M1 Mass flow rate versus time kg/h Temperature o C Pressure Bar Duration min M2 Mass flow rate of water versus kg/h time Temperature o C M3 Mass flow rate f condensate kg/h Temperature o C M4 Mass flow rate of water kg/h Temperature versus time o C M5 Mass of product in kg Temperature o C M6 Temperature o C
22 22 STEP 4.1: SPECIFICATION OF ENERGY CONSERVATION MEASURES All of the measures or performance improvement projects have to be specified to the level of a conceptual engineering design (see the example below). Project: CHP Scheme and position of NEW PLANT ECM #2: Gas Engine Installation Investment specification: Design and installation Supervision EQUIPMENT Gas engine and generator (electrical output 1,819 kw e ) Absorption chiller Capacity 861 kw R ; hot water 88/83 o C Heat exchanger for engine cooling (767 kw H ) Heat exchanger for flue gases (1148 kw H ) Transformer 0.4/20 kv Cooling tower Energy cost reduction: m$us/y Simple pay back period: 7 years Reduction in co 2 emission: 31.1 % LOCATION PREPARATION Site preparation 5000 Adoption the existing installation Gas connection installation 7500 MISCELLANEOUS 10 % of equipment cost TOTAL: $US
23 23 STEP 4.2: PREPARATION AND PRESENTATION OF DEA REPORT AND ACTION PLANS 1. Recommended chapters for DEA report Executive summary General data on factory and processes Observations and comments on operational, housekeeping and maintenance practice Current level of production and energy consumption and energy balances Specifications of identified energy performance improvement measures Expected values of energy cost savings Investment analysis: Economic aspects: Payback period and EIRR Financial aspects: Cash flow and FIRR Quantitative target for improving energy performance Implementation plan for achieving the set targets Technical details and specifications must be attached 2. Approach to preparing an energy action plan The order of consideration of energy conservation measures: i. Improvement of maintenance practices, ii. Improvement of operation practices, iii. Improvement of equipment efficiency, iv. Improvement of process efficiency. The order of priority for the implementation of energy conservation measures: i. Introduction of systematic energy management practices (including awareness, training and motivation programs) ii. Improvement of energy metering, control and monitoring (provide data for continuing improvement of efficiency) iii. iv. Improved housekeeping and maintenance Implementation of energy performance improvement projects with a short payback period 3. Selling of energy action plan to management i. Organize the session as a formal presentation to be attended by general, technical, production, financial and maintenance managers ii. Establish the relevance of energy costs iii. Explain the opportunities for cost reduction iv. Avoid technical jargon and detail v. Provide comparisons or benchmarks within the industry group vi. Provide a time scale in order to achieve results vii. Provide targets for the coming years viii. Specify investment requirements
Energy Efficiency in Industrial HVAC Systems
Energy Efficiency in Industrial HVAC Systems Heating, ventilation and air conditioning (HVAC) constitutes up to 35 percent of energy used in manufacturing facilities. This fact sheet is geared towards
More informationDesign Guide. Retrofitting Options For HVAC Systems In Live Performance Venues
Design Guide Retrofitting Options For HVAC Systems In Live Performance Venues Heating, ventilation and air conditioning (HVAC) systems are major energy consumers in live performance venues. For this reason,
More informationAir Conditioning. The opportunity for energy efficiency. Low cost actions to reduce energy usage now
Fact Sheet #6 Air Conditioning In this fact sheet you will discover: The opportunity for energy efficiency How air conditioning works Low cost actions to reduce energy usage now Investments to reduce costs
More informationPrinting and Publishing Energy Savings Guide
Printing and Publishing Energy Savings Guide Oregon printing and publishing plants face challenges of rising operating costs, environmental and other regulations, outdated equipment and customer demand
More informationCurrent state of plant Functioning as a peak and emergency centre. Statistics Accumulated operating hours:
Current state of plant Functioning as a peak and emergency centre Statistics Accumulated operating hours: D1-2-3-6-7: 43000 to 48000 hrs D4-5: 53000 to 57000 hrs D8: 33000 hrs Layout of the plant Index:
More informationHeating, Ventilation, Air Conditioning and Refrigeration (HVACR)
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) I. Demonstrate safety skills in typical HVACR work situations to NATE Core Installer Knowledge Areas for Technician Excellence for Safety
More informationPresented By: WALTER E. JOHNSTON, PE CEM, CEA, CLEP, CDSM, CPE <walterjohnston@bellsouth.net
Presented By: WALTER E. JOHNSTON, PE CEM, CEA, CLEP, CDSM, CPE
More informationEnergy Efficiency HOSPITALITY. www.energia.ie
Energy Efficiency HOSPITALITY www.energia.ie Your chance to reduce your business energy usage by as much as 20%! 20% is a significant figure and reducing your energy bill by this amount could make a real
More informationEnergy Saving Fact Sheet Boilers
Energy Saving Fact Sheet Boilers Turn a burning issue into real energy savings You need a boiler to heat your premises and provide hot water or to generate steam for use in industrial processes. Unfortunately,
More informationAIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries
AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries Hot tips and cool ideas to save energy and money! Air conditioning units or systems are often used by foundries
More informationSYLLABUS For BASIC TRADE COURSE (360 Hours) On REFRIGERATION AND AIR CONDITIONING
SYLLABUS For BASIC TRADE COURSE (360 Hours) On REFRIGERATION AND AIR CONDITIONING INDEX 1. Introduction 3 2. Objectives 3 3. Employment Opportunity 4 4. Course Structure 4 5. Entry Qualification 4 6. List
More informationPreventive Maintenance. State Energy Assessment Workshop By: DTE Energy Partnership & Services
Preventive Maintenance State Energy Assessment Workshop By: DTE Energy Partnership & Services Do you know? World wide research has shown that one of the reasons causing 80% of the accidents is deficient
More informationChapter 3.4: HVAC & Refrigeration System
Chapter 3.4: HVAC & Refrigeration System Part I: Objective type questions and answers 1. One ton of refrigeration (TR) is equal to. a) Kcal/h b) 3.51 kw c) 120oo BTU/h d) all 2. The driving force for refrigeration
More informationGAS HEATING IN COMMERCIAL PREMISES
ENERGY EFFICIENCY OFFICES GAS HEATING IN COMMERCIAL PREMISES www.energia.ie www.energia.ie Typically, energy reductions of 10% or more can be made easily through maintenance and low cost improvements.
More informationNatural Gas Energy Efficiency Opportunities for Commercial & Industrial Customers. Michael Pace Lead Engineer C & I Efficiency Programs
Natural Gas Energy Efficiency Opportunities for Commercial & Industrial Customers Michael Pace Lead Engineer C & I Efficiency Programs Agenda Energy Efficiency Opportunities for Small/Mid Commercial Facilities
More informationGuidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems
Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems If you're a designer or a BCA, this guidance on the energy efficiency of HVAC systems in commercial buildings may
More informationHEATING, VENTILATION & AIR CONDITIONING
HEATING, VENTILATION & AIR CONDITIONING as part of the Energy Efficiency Information Grants Program Heating and cooling can account for approximately 23 % of energy use in pubs and hotels 1. Reducing heating
More informationGlossary of Heating, Ventilation and Air Conditioning Terms
Glossary of Heating, Ventilation and Air Conditioning Terms Air Change: Unlike re-circulated air, this is the total air required to completely replace the air in a room or building. Air Conditioner: Equipment
More informationsteam centre of excellence Steam Boiler System Optimization
Steam Boiler System Optimization Introduction Gas Cost Metering Fluids Fuel, Water, Steam Steam Costs Boiler House Stack Losses Boiler Waterside Surfaces Blowdown Current Natural Gas Cost Projected Cost
More informationTIPS ON ENERGY SAVING
TIPS ON ENERGY SAVING IN HOME APPLIANCES AND ELECTRICITY SAFETY The Domestic Sector accounts for 30% of total energy consumption in the country. There is a tremendous scope to conserve energy by adopting
More information1. What percent of a commercial business s energy usage comes from their HVAC system? A. 13% B. 23% C. 33% D. 43% E. 53%
1 1. What percent of a commercial business s energy usage comes from their HVAC system? A. 13% B. 23% C. 33% D. 43% E. 53% 2. How much money do commercial facilities spend per square foot on energy costs
More informationEnergy Efficient Operations and Maintenance Strategies for Boilers
Energy Efficient Operations and Maintenance Strategies for Boilers Large, complex and widely used, industrial boilers are major consumers of fuel. Proper operations and maintenance (O&M) procedures must
More informationEvaluate, Clean, and Tune Guidance
Evaluate, Clean, and Tune Guidance The Evaluate, Clean and Tune (ECT) process serves three essential purposes in the Weatherization Assistance Program (WAP). The first is to evaluate the existing system
More informationAction Plan Template HVAC Page 1
Action Plan Template HVAC Page 1 Once Establish expected HVAC system efficiency - Write down the expected efficiency of HVAC systems to use as a baseline - Add this information to maintenance plan documentation
More informationAttachment J-C18.1. HVAC Work Instructions
. RFP: Attachment J-C18.1 HVAC Work Instructions NNC13ZFD017J SOW Item No. Title Page C18-02 Control Air Systems Annual PM 2 C18-03 Split System AC Indoor Section Annual PM 3 C18-04 Condensing Unit Semi-Annual
More informationHYBRID WAY EAF OFF GAS HEAT RECOVERY -ECORECS- MASANARI YAMAZAKI*1, YASUHIRO SATO*2, RYUTARO SEKI*3
HYBRID WAY EAF OFF GAS HEAT RECOVERY -ECORECS- BY MASANARI YAMAZAKI*1, YASUHIRO SATO*2, RYUTARO SEKI*3 SYNOPSIS JP Steel Plantech Co. has developed Hybrid system for EAF off-gas heat recovery, with EAF
More informationSaving energy in your business
Tips & Checklist: Saving energy in your business Whenever you save energy within your business you are also saving money. Electricity costs contribute to your business's financial bottom line so the more
More informationKU DESIGN GUIDELINES APPENDIX XVI RECOMMENDED BAS I/O CONTROL POINTS BY EQUIPMENT / SYSTEM
KU DESIGN GUIDELINES APPENDIX XVI RECOMMENDED BAS I/O CONTROL POINTS BY EQUIPMENT / SYSTEM AIR HANDLING UNITS... 1 CHILLERS... 2 COOLING TOWERS... 2 CLOSED LOOP COOLERS... 2 MISCELLANEOUS SUPPLY FANS...
More informationIntroduction to Process Engineering Economics. based on size of major equipment items allow to decide whether to invest in a detailed study
Reliability of estimates Accuracy versus cost Cost structure for building a new plant Typical plant cost evaluation methods Lang's factors Happel's method Chauvel-Guthrie's method Examples and applications
More informationHVAC Systems: Overview
HVAC Systems: Overview Michael J. Brandemuehl, Ph.D, P.E. University of Colorado Boulder, CO, USA Overview System Description Secondary HVAC Systems Air distribution Room diffusers and air terminals Duct
More informationIncreasing Natural Gas Boiler Efficiency by Capturing Waste Energy from Flue Gas
Increasing Natural Gas Boiler Efficiency by Capturing Waste Energy from Flue Gas Mark Schiffhauer, ATSI Engineering Services Cameron Veitch, Combustion and Energy Systems Scott Larsen, New York State Energy
More informationHow much do you know about HVAC? Try testing yourself with the following questions and then take a look at the answers on the following page.
Demystifying HVAC Test Your HVAC Knowledge By Ron Prager How much do you know about HVAC? Try testing yourself with the following questions and then take a look at the answers on the following page. 1)
More informationEnergy Efficiency in Steam Systems
Energy Efficiency in Steam Systems Fundamentals of Energy Efficiency: An Introductory Workshop April 2008 John S. Raschko, Ph.D. Mass. Office of Technical Assistance www.mass.gov/envir/ota (617) 626-1093
More informationLegacy Data Centres Upgrading the cooling capabilities What are the options?
Legacy Data Centres Upgrading the cooling capabilities What are the options? Presentation Structure What is a Legacy Data Centre? What is CRAC cooling? ASHRAE Standards Overview Available Cooling Systems
More informationFactory owners must ensure the boiler is:
Factory owners must ensure the boiler is: * Registered with the Boilers and Pressure Vessels Division, Labour Department * Examined by an appointed examiner and has a valid certificate of fitness * Supervised
More informationBuilding Energy Systems. - HVAC: Heating, Distribution -
* Some of the images used in these slides are taken from the internet for instructional purposes only Building Energy Systems - HVAC: Heating, Distribution - Bryan Eisenhower Associate Director Center
More informationEnergy Efficiency. Bars & RestauRants. www.energia.ie
Energy Efficiency Bars & RestauRants www.energia.ie 2 Your chance to reduce your business energy usage by as much as 20%! 20% is a significant figure and reducing your energy bill by this amount could
More informationSample Customer 123 Conservation Way TAMPA FL 33626 Tracking Number: 000675309
Thank you for completing the Online Home Energy Audit. Based on the answers that you provided in the questionnaire, the following is a complete analysis of your household's energy consumption. We have
More informationBEST PRACTICE GUIDE. Energy Efficiency: Steam, Hot Water and Process Heating Systems
BEST PRACTICE GUIDE Energy Efficiency: Steam, Hot Water and Process Heating Systems Contents 1 Introduction 4 2 The business benefits of steam system, hot water system and process heating system efficiency
More informationENERGY MANAGEMENT. for INDUSTRY AND BUSINESS
ENERGY MANAGEMENT for INDUSTRY AND BUSINESS [Principles of Energy Management] Denis Cooke Denis Cooke & Associates Pty Limited Phone + 61 2 9871 6641 Fax +61 2 9614 1723 Email: denis@decoa.com.au Web Site
More informationV. ENERGY SAVINGS IN INDUSTRY
V. ENERGY SAVINGS IN INDUSTRY A. Energy Use in Industry Industry is the major user of energy in modern society, accounting for roughly 40% of final energy use. Coal or oil are heavily used, especially
More informationSteam System Efficiency. Bill Lumsden Leidos Engineering
Steam System Efficiency Bill Lumsden Leidos Engineering Steam System Efficiency Steam System Efficiency Key Take-aways: Review of the properties of ice, water, and steam Learn the basics of steam trap
More informationA Cover HVAC ENERGY EFFICIENT
A Cover HVAC ENERGY EFFICIENT EQUIPMENT toolkit 1 CONTENTS AND PARTNERS 2 Introduction 3 equipment & processes 3 Optimise operating settings 2 upgrade equipment 4 Seal the building 5 Rearrange air conditioning
More informationENERGY EFFICIENCY ENERGY EFFICIENCY: Saving Dollars While Clearing the Air
: Saving Dollars While Clearing the Air After labor and food, energy is the largest controllable cost in a restaurant s operation. And energy is a great place to start in becoming a green restaurant because
More informationSECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS
SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES After studying this unit, the reader should be able to explain the purpose of the condenser in a refrigeration system. describe differences
More informationEnergy Efficiency Tips for Businesses
Energy Efficiency Tips for Businesses Top 10 Tips Lighting Tips Heating and Cooling Temperature Control Office Equipment Laundry Service Refrigeration Equipment Food Service Equipment Employee Involvement
More informationHybrid Modeling and Control of a Power Plant using State Flow Technique with Application
Hybrid Modeling and Control of a Power Plant using State Flow Technique with Application Marwa M. Abdulmoneim 1, Magdy A. S. Aboelela 2, Hassen T. Dorrah 3 1 Master Degree Student, Cairo University, Faculty
More informationLesson 36 Selection Of Air Conditioning Systems
Lesson 36 Selection Of Air Conditioning Systems Version 1 ME, IIT Kharagpur 1 The specific objectives of this chapter are to: 1. Introduction to thermal distribution systems and their functions (Section
More informationGlossary of HVAC Terms
Glossary of HVAC Terms Heating, Ventilation and Air Conditioning (HVAC) is a major sub- discipline of mechanical engineering. The goal of HVAC design is to balance indoor environmental comfort with other
More informationXcel Business Customers: Program and Rebate Summary
Xcel Business Customers: Program and Rebate Summary Rebates for New Energy-Efficient Equipment Xcel offers prescriptive rebates to its business customers. What s a prescriptive rebate? It simply means
More informationCondensing Economizers Workshop Enbridge Gas, Toronto. MENEX Boiler Plant Heat Recovery Technologies. Prepared by: Jozo Martinovic, M A Sc, P Eng
Condensing Economizers Workshop Enbridge Gas, Toronto MENEX Boiler Plant Heat Recovery Technologies Prepared by: Jozo Martinovic, M A Sc, P Eng MENEX Innovative Solutions May 15, 2008 MENEX INC. 683 Louis
More informationFederal Wage System Job Grading Standards for Air Conditioning Equipment Operating, 5415. Table of Contents
Federal Wage System Job Grading Standards for Air Conditioning Equipment Operating, 5415 Table of Contents WORK COVERED... 2 WORK NOT COVERED...2 TITLES... 2 GRADE LEVELS... 2 HELPER AND INTERMEDIATE JOBS...
More information3/29/2012 INTRODUCTION HVAC BASICS
INTRODUCTION HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O HVAC systems or Heating, Ventilating and Air-Conditioning systems control the environment for people and equipment in our facilities.
More informationCenter for Energy Education Laboratory
Paper ID #7072 Center for Energy Education Laboratory Dr. Robert Gilbert, Sinclair Community College Robert B. Gilbert, Ph.D., LEED AP, BA, is an Associate Professor of Energy Management Technology, and
More informationRecover Heat from Boiler Blowdown Water
Prepared for California Energy Commission (CEC) Prepared By: Southern California Gas Company (A Sempra Energy Utility) E3M Inc. May 2012 i Disclaimer The CEC and its contractor, Southern California Gas
More informationCHAPTER 8 HVAC (Heating, Ventilation, and Air-Conditioning)
CHAPTER 8 HVAC (Heating, Ventilation, and Air-Conditioning) Objectives Survey current HVAC system(s), operating procedures, and maintenance schedule. Analyze results of energy audit for HVAC system(s)
More informationEnergy Saving Ideas for Your Box Plant
General Session Energy Saving Ideas for Your Box Plant Moderator: Jeff Pallini Fosber America, Inc. Program Overview: Immediate Ideas: Jim Simko of Simtek Systems, Inc. Mid-Term Ideas: John Donahue of
More informationSWIMMING POOL HEAT PUMP
SWIMMING POOL HEAT PUMP Installation & User Manual Model HP40B HP50B HP65B Hayward Pool Products Canada, Inc. T: 1-888-238-7665 www.haywardpool.ca CONTENT I. Application 4 II. Features 4 III. Technical
More informationRESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00
RESIDENTIAL HEATING OIL SERVICE CONTRACT This service contract covers all routine service and maintenance of your residential oil fired furnace or boiler. In addition this contract covers all service calls
More informationRPV - RP - RA air handling units
APPLICATIONS Heating, ventilation, cooling >> FACTORIES >> WAREHOUSES >> HALLS >> DISTRIBUTION CENTRES >> COMMERCIAL PREMISES >> PLACES OF WORSHIP RPV - RP - RA air handling units www.reznor.eu RPV - RP
More informationFailure code manual. content
Failure code manual content 一 wall split AC series 2 二 floor standing AC series. 4 三 portable AC series.. 5 四 dehumidifer 6 五 DC inverter single split series...7 六 DC inverter multi-split series 10 1 一
More information5. State the function of pulveriser. The pulverisers are the equipments which are used to powdered coal.
413 POWER PLANT ENGINEERING PART-A 1. Define Power. Power is the rate at which energy is used (or) Energy/time. 2. What are the types of fuels? Solid fuel Liquid fuel Gaseous fuel (Any one among the above
More informationMechanical Rooftop Custom Capabilities
Mechanical Rooftop Custom Capabilities Mechanical Construction Capabilities Price manufactures a wide range of custom gas heat and DX cooled units to meet your new construction and retrofit needs. In addition
More informationNYC Department of Education Building Condition Assessment Survey 2014-2015 BROADWAY EDUCATION CAMPUS - MANHATTAN, 26 BROADWAY, MANHATTAN, NY, 10004
School: InspectionId Asset Data Inspection Type Building Assessment Survey 204-205 BROADWAY EDUCATION CAMPUS - MANHATTAN, 26 BROADWAY, MANHATTAN, NY, 0004 Time In Last Edited 255 MECHANICAL 205-05-8 09:00AM
More informationSECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
More informationTraining for Building Technicians: Energy Efficiency & Sustainability (BEST) Program. Seminar Outline & Sample BEST Exam Questions
Training for Building Technicians: Energy Efficiency & Sustainability (BEST) Program Seminar Outline & Sample BEST Exam Questions Buildings in the United State consume a significant amount of energy. According
More informationThe Only GUY To Call. Why are my utility bills so high? What can I do to lower my energy expenses?
The Only GUY To Call May 2014 412.885.2356 Why are my utility bills so high? What can I do to lower my energy expenses? Did you know... that between 2007 and 2012, the average U.S. household spent more
More informationCHAPTER 9: WATER HEATING
Chapter 9: Water Heating 145 CHAPTER 9: WATER HEATING Energy costs for water heating can be as great as the costs for heating, for an energy efficient house, in a mild climate. Estimating hot water usage
More informationBoiler and Burner Cleaning and Servicing Specifications
Boiler and Burner Cleaning and Servicing Specifications The Town of Groton of Public Works Department is requesting bids to provide manufacturers recommended maintenance, repairs and emergency service
More informationPLP - TERMS AND CONDITIONS
PLP - TERMS AND CONDITIONS 2014-2015 Philadelphia Gas Works Residential Parts & Labor Plan Contract This Residential Parts & Labor Plan Contract (this Plan ) is available to customers of the Philadelphia
More informationHOW TO SELECT A LOW VOLUME (L.V ) BOILER
HOW TO SELECT A LOW VOLUME (L.V ) BOILER FREQUENTLY ASKED QUESTIONS OR COMMENTS ON BOILERS Dear Potential Customer: Low Volume Operator Exempt boilers have been marketed in Ontario to eliminate the requirement
More informationCommissioning - Construction Documents (Page 1 of 6)
Commissioning - Construction Documents (Page 1 of 6) A. General Information Climate Zone: Building Type: Conditioned Area (sf): Reviewer's Name: Reviewer's Agency: Note: Design Review for each system/subsystem
More informationASTACEA4 Inspect complex/central air conditioning systems
Overview This Unit covers the competences required to inspect complex/central air conditioning systems as defined by the CIBSE TM 44 Figure 1.1: Summary of system types and their component parts. The air
More informationELECTRODE BOILERS VAPOR POWER INTERNATIONAL
ELECTRODE BOILERS WITH JET-FLO Technology VAPOR POWER INTERNATIONAL ELECTRODE boilers The Electrode Steam Boiler with Jet-Flo technology consists of an insulated pressure vessel and is fully enclosed in
More informationBoiler Preparation, Start-Up and Shutdown
Boiler Preparation, Start-Up and Shutdown Learning Outcome When you complete this module you will be able to: Describe the basic preparation of a boiler for start-up, and the start-up and shutdown procedures.
More informationJob Grading Appeal Decision Under Section 5346 of Title 5, United States Code
U.S. Office of Personnel Management Office of Merit Systems Oversight and Effectiveness Classification Appeals and FLSA Programs Dallas Oversight Division 1100 Commerce Street, Room 4C22 Dallas, TX 75242
More informationMechanical Engineering Technician- Plant Technician
Mechanical Engineering Technician- Plant Technician A competent Mechanical Engineering Technician- Plant Maintenance is expected to: 1. Ability to plan and execute work in a safe and responsible manner
More informationHeat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools
Heat Recovery Dehumidification (HRD) system Designed for municipal swimming pools A dehumidification and ventilation system with dynamic heat pump heat recovery to swimming pool water and air ENVIRONMENTAL
More informationIGEMA BOILER LEVEL & TDS CONTROLS
IGEMA BOILER LEVEL & TDS CONTROLS IGEMA offers boiler level and TDS control products of the highest quality standard, being certified to ISO 9001. Made in Germany, IGEMA products are manufactured in compliance
More informationAN AUDITAC PROPOSED PRELIMINARY AUDIT METHODOLOGY FOR AIR- CONDITIONING FACILITIES
Technical guides for owner/manager of an air conditioning system : volume 4 AN AUDITAC PROPOSED PRELIMINARY AUDIT METHODOLOGY FOR AIR- CONDITIONING FACILITIES Team France (Project coordinator) Armines
More informationData Realty Colocation Data Center Ignition Park, South Bend, IN. Owner: Data Realty Engineer: ESD Architect: BSA LifeStructures
Data Realty Colocation Data Center Ignition Park, South Bend, IN Owner: Data Realty Engineer: ESD Architect: BSA LifeStructures Project Overview Data Realty is a data center service provider for middle
More informationCondensing Boiler Efficiency
Condensing Boiler Efficiency Date: July 17, 2012 PRES E NT ED BY DO N L E O NA RDI LE O N A RD I I NC. HV AC T RAI N I N G & C ON SU LT IN G Concepts 1 The current state of evolution in boiler design 2
More informationBest Practice Guide BPGCS007
Best Practice Guide BPGCS007 ENERGY MANAGEMENT Introduction: With rising fuel costs, opening of electricity and gas markets to alternate suppliers and climate change, the requirement to monitor and reduce
More informationContinuous flow direct water heating for potable hot water
Continuous flow direct water heating for potable hot water An independently produced White Paper for Rinnai UK 2013 www.rinnaiuk.com In the 35 years since direct hot water systems entered the UK commercial
More information1932 Lexington Houston, Texas 77098-4220 (713) 524-4877. Recommendations for installation of cooling systems
1932 Lexington Houston, Texas 77098-4220 (713) 524-4877 The purpose for this information is to provide a better understanding of the HVAC equipment, components, designs, and installations, of HVAC system
More informationALUMINUM. BestPractices Assessment Case Study. Alcoa North American Extrusions Implements Energy Use Assessments at Multiple Facilities.
ALUMINUM BestPractices Assessment Case Study August 2001 OFFICE OF INDUSTRIAL TECHNOLOGIES ENERGY EFFICIENCY AND RENEWABLE ENERGY, U.S. DEPARTMENT OF ENERGY BENEFITS Assesses core systems commonly found
More informationNational Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook
National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook Trainee:... Training Provider:... Year:... Trainee Contact no:... Competency Based Skill Training Logbook Introduction
More informationENERGY CONSERVATION PRESENTATION BY : PCG CORPORATION
ENERGY CONSERVATION PRESENTATION BY : PCG CORPORATION ENGINEERING SERVICES: Clients References Energy Projects Bristol Myers Barceloneta Electric Bill Analysis Lilly Guayama Electric Bill Analysis Bristol
More informationDrying of Woody Biomass. Process Engineering / GEA Barr-Rosin
Drying of Woody Biomass BioPro Expo & Marketplace / Atlanta, GA / March 14-16, 2011 Drying of Woody Biomass Conventional Direct Fired Dryer Technology Proprietary work of the Copyright Owner Issues with
More informationHEATER, AIR CONDITIONING AND VENTILATION
55-1 GROUP 55 HEATER, AIR CONDITIONING AND VENTILATION CONTENTS GENERAL DESCRIPTION 55-2 HEATER AND AIR CONDITIONING SYSTEM 55-4 HEATER CONTROL 55-6 A/C-ECU 55-7 A/C COMPRESSOR 55-9 CONDENSER 55-9 DUCT
More informationSubpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,
4658.4500 PLUMBING SYSTEMS; NEW CONSTRUCTION. Subpart 1. Installation. All plumbing systems must be installed and tested according to this chapter and chapter 4715, the Minnesota Plumbing Code. Subp. 2.
More informationChilled Water HVAC Systems
Chilled Water HVAC Systems By Ron Prager, Brinco Mechanical Services, Inc. Types of water based systems: There are three types of HVAC systems that utilize water as a heat transfer medium. The first system,
More informationExample Retrocommissioning Measure: Opening Throttled Discharge Valves
Opening Throttled Discharge Valves This 21-story building, constructed in 1997, is located in Oregon and contains 589,000 gross square feet of mostly office occupancy. The HVAC system includes six large
More informationOn request of Akzo Nobel Dynamo Project Team we ve surveyed the energy efficiency of the compressed air system in the Barcelona Deco & A/AS plant.
Postbus 9058 6070 AB Swalmen (NL) Akzo Nobel Car Refinishes S.L./Coatings S.L. Att. Mr. Cesar Franch Tel. +31(0)77-7676276 Fax +31(0)77-7676286 e.mail info@ants-tech.nl website www.ants-tech.nl cesar.franch@akzonobel.com
More informationADDENDUM NO. 1 TO THE BIDDING DOCUMENTS. HVAC SERVICE AND MAINTENANCE Saint Clair County MidAmerica Saint Louis Airport.
ADDENDUM NO. 1 TO THE BIDDING DOCUMENTS DATE: May 6, 2016 HVAC SERVICE AND MAINTENANCE Saint Clair County MidAmerica Saint Louis Airport BIDS CLOSE: May 12, 2016, at 2:30 p.m., Local Time TO ALL BIDDERS
More informationThe main steam enters the building in the basement mechanical room; this is where the condensate line also leaves the building.
MSV: Square Footage: 24,844 No. of Floors: 1 Year Built: 1963 Type of Use: Lounge and dining area open all night for snacks Steam Water-cooled condenser, 50-Ton York unit with a 6 cylinder-reciprocating
More informationResources for School Energy Managers
Resources for School Energy Managers Cooling can present a substantial energy cost to schools. Temperatures of 24 to 27 C with less than 60% relative humidity give acceptable comfort in summer. Higher
More informationLife Cycle Costing Analysis of Water-cooled Chillers. Chillventa Nuremburg, Germany
Life Cycle Costing Analysis of Water-cooled Chillers Chillventa Nuremburg, Germany Spring 2012 Description Life Cycle Cost Analysis is a method of determining and comparing the total costs of investment
More informationChicago Stationary Engineer Licensure Examination Information
Chicago Stationary Engineer Licensure Examination Information This candidate guide should help you prepare for the Chicago Stationary Engineer licensure examination. Part I contains general information
More informationCOGENERATION. This section briefly describes the main features of the cogeneration system or a Combined Heat & Power (CHP) system. 36 Units.
COGENERATION 1. INTRODUCTION... 1 2. TYPES OF COGENERATION SYSTEMS... 2 3. ASSESSMENT OF COGENERATION SYSTEMS... 10 4. ENERGY EFFICIENCY OPPORTUNITIES... 14 5. OPTION CHECKLIST... 16 6. WORKSHEETS... 17
More information