INTERNATIONAL MULTI-DROP BUS INTERFACE STANDARD
|
|
|
- Griselda Lucy Brooks
- 10 years ago
- Views:
Transcription
1 NATIONAL AUTOMATIC MERCHANDISING ASSOCIATION INTERNATIONAL MULTI-DROP BUS INTERFACE STANDARD As Prepared by the NAMA Vending Technology Standards Committee American Edition First Version Revised August 19,1994 National Automatic Merchandising Association 20 N. Wacker Drive, Suite 3500 Chicago, Illinois USA FAX
2
3 International Multi-Drop Bus Interface Standard Introduction Table of Contents Section 1 General Information 1. Introduction 2. Operational and Application Notes Section 2 Communication Format 1. Byte Format 2. Block Format 3. Peripheral Addresses 4. Software Operational Rules 5. Typical Session Examples Section 3 B US Timing 1. Timing Definitions 2. Timing Specifications 3. Timing Diagram Section 4 Hardware Specification 1. Bus Power Supply Definition 2. Bus Transmitter/Receiver Specification 3. Connector Specification 4. Example Schematic 5. Software Notes Section 5 Changer/Peripheral Communication Specifications 1. Introduction 2. VMC Commands 3. VMC Command Format 4. Changer Non-Response Time 5. changer Power Requirements
4
5 - Section 6 Bill Validator/Peripheral Communication 1. Introduction 2. VMC Commands 3. VMC Command Format 4. Bill Validator Non-Response Time 5. Bill Validator Power Requirements Specifications Section 7 Card Reader/Peripheral Communication Specifications 1. Introduction 2. State Definitions 3. Command Protocol 4. Card Reader Command Response Formats 5. Card Reader Non-Response Time 6. Card Reader Power Requirements
6
7 Introduction Foreword This voluntary Standard contains basic requirements for vending machines within the limitations given below and in the General Information section of this Standard. These requirements are based on sound engineering principles, research, field experience and an appreciation of the problems of manufacture, installation and use derived from consultation with and information obtained from manufacturers, users and others having specialized experience. These requirements are subject to revision as further experience and investigation may show it necessary or desirable. NAMA, in performing its functions in accordance with its objectives, does not assume or undertake to discharge any responsibility of the manufacturer or any other party. The opinions and findings of NAMA represent its professional judgment given with due consideration to the necessary limitations of practical operation and state of the art at the time the NAMA Standard is processed. NAMA shall not be responsible to anyone for use or reliance upon Standard by anyone. NAMA shall not incur any obligation or liability for damages, including consequential damages, arising out of or in connection with the use, interpretation of, or reliance upon this Standard. Standard Review A complete review of this standard shall be conducted at least every five years to keep requirements consistent with technology. These reviews shall be conducted by representatives from industry and user groups on the NAMA Vending Technology Standards Committee at that time. October 19, 1993 i. 1
8
9 I Section 1 General Information 1. Introduction This document defines a serial bus interface for electrically controlled vending machines. The interface is a 9600 baud Master- Slave arrangement where all peripherals are Slaves to a Master controller. The intent of this document is to standardize vending machines that employ electronic control (traditionally known as vending mechanism controller - VMC) so that all vending and peripheral equipment communicates identically. 2* Operational and Application Notes The serial bus, or Multi-Drop Bus (MDB) is configured for Master- Slave operation. There is one Master with capability of communicating with up to thirty-two peripherals. The Master is defined as the Vending Machine Controller (VMC). Each peripheral is assigned a unique address and command set. The master will poll the Bus for peripheral activity. That is, each peripheral is asked for activity, and responds with either an acknowledge, negative acknowledgment, or specific data dependent on its current activity. If a peripheral does not respond within a predefine time, (t-non-response as defined in the peripheral sections) it is assumed that it is not present on the Bus. Bus interference, or crashes are prevented because each peripheral only responds upon being polled. Since there is only one master, and all communication is initiated by the Master, Bus crashes are easily precluded. All peripherals will recognize a disable command, or commands, sent by the Master. This allows for disabling of individual peripherals for various reasons, for example, power management techniques. October 19,
10 Error checking and correction is accomplished by using checksums (CHK) and a retransmit command. October 19,
11 Section 2 Communication Format 1. Byte Format Baud Rate: Serial Bit Format: 9600 NRZ 1 Start Bit 8 Data Bits 1 Mode Bit 1 Stop Bit 11 Bits Total LSB MSB Start O Mode Stop Mode Bit: Master-to-Peripheral The mode bit differentiates between ADDRESS bytes and DATA bytes. ADDRESS bytes must be read by all peripherals, DATA bytes are only read by the peripheral that is active. An active peripheral is defined as a device that has successfully established a communication session with the Master. The mode bit is set (logic one) to indicate an ADDRESS byte, and not set (logic zero) to indicate a DATA byte. Mode Bit: Peripheral-to-Master The mode bit must be set on the last byte sent when data is sent from a Slave to the Master. 2. Block Format M aster -to -Peripheral A Communication Block for Master-to-Slave transmissions is defined as an Address byte, optional data bytes, and a CHK byte. A block is limited to a maximum of thirty-six (36) bytes. October 19,
12 The upper five bits (MSB) of the Address Byte will be used for addressing. That is, bits 7,6,5,4,3 of the previous byte description will be used for addressing. The lower three bits (i.e. 2,1,0) of the Address Byte will contain peripheral specific commands. This will allow up to eight instructions to be embedded in the first byte of a block. The VMC Master will respond to data from a peripheral with an Acknowledgment (ACK), Negative Acknowledgment (NAK), or Retransmit (RET) command. These are defined later in the document. The 5 ms time-out (t-response) described in the Bus Timing section of this document is the equivalent of a NAK command. Peripheral - to - Master A Communication Block for Slave-to-Master transmissions consists of either a data block and a CHK byte, a acknowledgment (ACK), or a negative acknowledgment (NAK). The 5 ms time-out (t-response) described in the Bus Timing section of this document is the equivalent of a NAK command. In addition, it is recommended that the peripheral use this time-out as the NAK when a reception error of the ADDRESS byte occurs. This will prevent several peripherals from trying to simultaneously respond with a NAK. A data block consists of one or more data bytes followed by a CHK byte. The CHK byte is defined later in this document. The data block and CHK byte are limited to a maximum size of 36 bytes. A CHK byte is not required when a peripheral responds with NAK or ACK byte. ACK and NAK are defined later in this document. The peripheral must set the mode bit on the last byte sent to signify end of transmission. This will be either the CHK byte of a block, a NAK byte, or an ACK byte. The mode bit must not be set except for the conditions above. October 19,
13 A peripheral response of ACK or NAK signifies the end of the exchange. When a peripheral responds with a block, the VMC must respond with an ACK, NAK or RET command, CHK Byte A CHK byte must be sent at the end of each block of data. The CHK byte is a checksum calculated by adding the ADDRESS byte and all DATA bytes. The CHK byte is not included in the summation. The carry bit for CHK additions is ignored since the CHK byte is limited to eight bits. The following example shows a CHK byte calculation for a possible response to a STATUS command sent to a USA changer slave. See section 5 for details of byte meanings. 02H OOH 01 H 05H 02H OOH 07H 01 H 02H 05H 14H FFH 12CH Changer feature level Country code for USA Country code for USA Coin scaling factor Decimal place Coin type routing Coin type routing Coin type O has value of 1 scaling factor Coin type 1 has value of 2 scaling factor Coin type 2 has value of 5 scaling factor Coin type 3 has value of 20 scaling factor coin type 4 is a token Therefore the CHK byte would be equal to 2CH A checksum will be performed on all full blocks of communication. A checksum will not be performed on ACK, NAK, or RET bytes. The following codes are reserved for the ACK, NAK and RET bytes: ACK OOH (acknowledgment/checksum correct) AAH (Retransmit. this byte) Only the VMC can transmit NAK FFH (Negative acknowledge) October 19,
14 The VMC and peripheral must also recognize the 5 ms time-out (tresponse) as a NAK. NOTE: To improve system reliability it is recommended that when receiving ACK, NAK, or RET the receiving device counts the number of bits set in the byte. This method will require at least two bit errors in the byte before the byte can be mis-interpreted. Bus Reset The VMC may reset all peripherals by pulling the transmit line active for a minimum of 100 ms. This informs all peripherals to abort any activity and return to its power-on reset state. Details of this state for each peripheral are provided in later sections of this document. It is recommended that the VMC re-initialize each peripheral after this type of reset. 3. Peripheral Addresses The addresses below are defined. Address OOOOOB 00001B OOO1OB 00011B OO1OOB 00101B 00110B B 11101B 1111OB 11111B Definition Reserved for future expansion Changer Card Reader Audit System Display Energy Management System Bill Validator Reserved for Future Standard Peripherals.. Reserved for Future Standard Peripherals Vending Machine Specific Peripheral 1 Vending Machine Specific Peripheral 2 October 19,
15 . Vending Machine Specific peripheral addresses (addresses 1111OB and 1llllB) are reserved for Non-Standard or proprietary applications. These devices are allowed a unique set of commands. All other peripherals are defined as Standard devices. These peripherals must follow the specifications to ensure compatibility between manufacturers. 4. Software Operational Rules The VMC must regulate the power budget. That is, peripherals must be enabled and disabled dependent on power availability. The power bus is defined later in this document. During multi-byte messages the most significant byte is sent first. The following are recommendations for the methods of VMC to peripheral software operation. Each peripheral should be polled every milliseconds. If a peripheral has not responded to a poll for its maximum Non-Response time, the VMC should continue to poll the peripheral at least every ten seconds with a RESET command. 5. Typical Session Examples A. The diagram below represents a typical transmission when a peripheral is idle. VMC: ADD* Peripheral: ACK* B. The diagram below represents a typical transmission when a peripheral has data to return. October 19, e 5
16 VMC: ADD* ACK Peripheral: DAT DAT CHK* c The diagram below represents a typical transmission when the VMC has data to send. VMC: Peripheral: ADD* DAT DAT *Indicates mode bit set D. The diagram below represents VMC determines a CHK is not one of two ways: ACK* a typical transmission when the correct. The VMC will respond Send a NAK to the peripheral to indicate that the information was not received correctly then perform other tasks, OR The VMC may send a retransmit (RET) command alerting the peripheral to try again. VMC: Peripheral: *Indicates mode bit set. DAT DAT CHK* DAT DAT CHK* October 19,
17 Multi-Drop Bus Section 3 Bus Timing 1. Timing Definitions Baud rate = t = inter-byte (max. ) t = response (max. ) t break (VMC) t = setup The rate of bit transfer per second. The maximum time allowed between bytes in a block transmission. The maximum time any device, master or peripheral, will take to respond to a valid communication. The minimum time of the Bus Reset signal sent by the VMC to reset all peripherals The minimum set-up time before the VMC attempts to communicate after a reset signal. 2. Timing Specifications Baud Rate = %/-2% NRZ t t t t inter-byte (max. ) response (max.) break (min.) setup (min.) = 1.0 ms = 5.0 ms = 100 ms = 200 ms October 19,
18 NOTE: All peripherals have the option of not responding to the VMC. Non-response timing is defined in the peripheral specification. 3. Timing Diagram NOTE: * indicates that the mode bit is set October 19,
19 Section 4 Hardware Specification 1. Bus Power Supply Definition The information below defines the minimum VMC voltage output. The actual current ratings per peripheral will be defined in their respective sections. Power supply filtering is optional, therefore if a peripheral requires more power, or tighter regulation, they may elect to supply their own power, or filtering, from available sources elsewhere in the machine. VMC Voltage Output: Minimum = Nominal = Maximum = 20 VDC rms.(rectified and optionally filtered) 34 VDC unreg.(rectified and filtered) 24 VDC rms.(rectified only) 42.5* VDC(ripple voltage upper limit) * High line input may allow 45 VDC peak (max.). 2. Bus Transmitter/Receive r Specification The following section describes the 5V, optically isolated, current loop system between the Master and the Slave. VMC Master: Transmit: Minimum source current (active): 100 4V Maximum leakage current (inactive): 100 µa NOTES: 1) The transmit line must be able to withstand a short while in the active mode. October 19,
20 2) 15 ma should be added for each peripheral over six. Receive: Minimum input Maximum input current (active): current (inactive): 15 IV 1 ma Peripheral Slave: Receive: Transmit: Maximum input Maximum input 3. Connector Specification Peripheral: Minimum sink current (active): 15 IV Maximum leakage current (inactive): 30 µa Connector: Terminals: Molex (6 Circuit receptacle) Molex (sockets) Strain Relief: Molex Bus Harness: Connector: Terminals: Molex (6 Circuit plug) Molex (Pins) Connector Pin-out: Line 1-34 VDC Line 2 - DC power return October 19,
21 Line 3 - N/C Line 4 - Master Receive Line 5 - Master Transmit Line 6 - Communications Common October 19,
22 4 Example Schematic. October 19, 1993
23 VMC/Peripheral Section 5 Change r Communication Specifications 1. Introduction This section defines by a coin accepting binary. the communication bytes sent and received device ( Changer ). The changers address is Unless stated otherwise, all information is assumed to be in a binary format. There are currently two levels of support defined for the coin mechanism interface, Level 2 and Level 3. The level of coin mechanism operation is sent to the VMC in the response to the STATUS command (defined later in this section). The following paragraphs w i 11 define how a VMC should differentiate between each level. Level 2 Changers For level 2 changers, VMC operation consists of monitoring inputs from the coin mechanism, accumulating credit, issuing a coin acceptance disable command when appropriate, and issuing appropriate pay out commands based on the VMC resident payout algorithms and escrow rules. Level 3 Changers For level 3 changers, VMC operation is the same as defined above for level 2, with the addition of the EXPANSION command and its implications (defined later in this section). The VMC has the option of sending the EXPANSION command to the coin mechanism to determine the coin mechanism s manufacturer code, serial number, model/tuning revision, software version, and optional features. Based on the optional feature information the VMC will determine the appropriate operating mode (in other words, modes that both the coin mechanism and the VMC can support), enable any appropriate coin mechanism features by sending an appropriate feature enable command back to the coin mechanism, and enter the proper opera ting mode. This technique allows all VMCs and August 19,
24 peripherals to accommodate existing feature capabilities and provides a means for upgrading Level 3 equipment. 2. VMC Commands Command Hex Code Description RESET STATUS TUBE STATUS POLL COIN TYPE DISPENSE 08H 09H OAH OBH OCH ODH Command for changer to self-reset Request for changer status. Request for changer tube status. Request for changer activity status. Signifies coin types accepted and allowable coin dispensing. This command is followed by setup data. See command format section. Command to dispense a coin type. Followed by coin type to dispense. See command format section. EXPANSION OFH Command to allow addition of features and COMMAND future enhancements. Changers at feature level 2 do not support this command. NOTE: An EXPANSION command is always followed by a subcommand. This command allows for feature additions. 3. VMC Command Format VMC Command Code VMC Data RESET 08H No data bytes This command is the vehicle that the VMC should use to tell the changer that it should return to its default operating mode. With the exception of the ACK response, it should abort all communication and disable all acceptance until otherwise instructed by the VMC. August 19,
25 VMC Command Code Changer Response Data STATUS 09H 23 bytes: Z1-Z23 Z1 = Changer Feature Level - 1 byte Indicates the feature level of the changer. This will distinguish the changers feature level to the VMC. Current defined levels: Level 2: Level 3: Supports core command set. These are: RESET, STATUS, TUBE STATUS, POLL, COIN TYPE, and DISPENSE. Supports level two and the EXPANSION command addition changer model number, manufacturer code, turning revision, etc. See the details of EXPANSION command later in this document. Z2 - Z3 = Country Code - 2 bytes The International Telephone Code for the country that the changer is set-up for, is sent in packed BCD. For example, the USA code is 00 O1H Z4= Coin Scaling Factor - 1 byte All accepted coin values must be evenly divisible by this number. For example, this could be set to 05H for the USA nickel. Z5 = Z6 - Z7 = Decimal Places - 1 byte Indicates the number of decimal places on a credit display. For example, this could be set to 02H in the USA. Coin Type Routing - 2 bytes Indicates what coin types can be routed to the Changer s tubes. August 19,
26 b15 b14 b13 b12 bll bl0 b9 b8 I b7 b6 b5 b4 b3 b2 bl bo Z6 Z7 Bit is set to indicate a coin type can be routed to the tube. Valid coin types are O to 15. Z8-Z23= Coin Type Credit - 16 bytes Indicates the value of coin types O to 15. Values must be sent in ascending order. This number is the coin s monetary value divided by the coin scaling factor. Unused coin types are sent as OOH. Unsent coin types are assumed to be zero. It is not necessary to send all coin types. Coin type credits sent as FFH are assumed to be vend tokens. That is, their value is assumed to worth one vend. The bytes position in the 16 byte string indicates the coin type(s). For example, the first byte sent would indicate the value of coin type O, the second byte sent would indicate the value of coin type 1, and so on. For example, the USA coin types may be; Coin type O = nickel, Coin type 1 = dime, Coin type 2 = quarter, Coin type 3 = dollar. VMC Command Code Changer Response Data TUBE STATUS OAH 18 bytes: Z1 - Z18 Z1 - Z2 = Tube Full Status - 2 bytes Indicates status of coin tube for coin types O to 15. b15 b14 b13 b12 bll b10 b9 b8 I b7 b6 b5 b4 b3 b2 bl bo Z1 Z2 A bit is set to indicate a full tube. For example, bit 7 = set would indicate the tube for coin type 7 is full. Z3 - Z18 = Tube Status - 16 bytes Indicates the greatest number of coins that the changer knows definitely are present in the coin August 19,
27 tubes. A bytes position in the 16 byte string indicates the number of coins in a tube for a particular coin type. For example, the first byte sent indicates the number of coins in a tube for coin type O. Unsent bytes are assumed to be zero. NOTE: If a changer can detect a tube jam, defective tube sensor, or other malfunction, it will indicate the tube is bad by sending a tube full status and a count of zero for the malfunctioning coin type. VMC Command Code Changer Response Data POLL OBH 16 bytes: Z1 - Z16 Z1 - Z16 = Changer Activity - 16 bytes Indicates the changer activity. If there is nothing to report, the changer should send only an ACK. Otherwise, the only valid responses are: Coins Dispensed Manually: Byte 1 Byte 2 (1yyyxxxx) (zzzzzzzz) yyy = The number of coins dispensed. xxxx = The coin type dispensed (O to 15) zzzzzzzz = The number of coins in the tube. Coins Deposited: Byte 1 Byte 2 (01yyxxxx) (zzzzzzzz) yy = Coin routing. 00: CASH BOX 01: TUBES 10: NOT USED 11: REJECT xxxx = Coin type deposited (O to 15). zzzzzzzz = The number of coins in the tube for the coin type accepted. August 19,
28 Status: ( ) = ( ) = ( ) = ( ) = ( ) = ( ) = ( ) = ( ) = ( ) = ( ) = ( ) = ( ) = ( ) = ( ) = ( ) = Escrow request l - An escrow lever activation Changer Payout changer is busy devices. No Credit l - A has been detected. Busy 2 - The activating payout coin was validated but did not get to the place in the system when credit is given. Defective Tube Sensor l - The changer has detected one of the tube sensors behaving abnormally. Double Arrival l - Two coins were detected too close together to validate either one. Acceptor Unplugged 2 - The changer has detected that the acceptor has been removed. Tube Jam l - A tube payout attempt has resulted in jammed condition. ROM checksum error l - The changers internal checksum does not match the calculated checksum. Coin Routing Error l - A coin has been validated, but did not follow the intended routing. Changer Busy 2 - The changer is busy and can not answer a detailed command right now. Changer was Reset l - The changer has detected an Reset condition and has returned to its power-on idle condition. Coin Jam l - A coin(s) has jammed in the acceptance path. Not Used Not Used Not Used August 19,
29 Slug : (00lxxxxx) = xxxxx is the number of slugs since the last activity. NOTES: The Changer may send several of one type activity, up to 16 bytes total. This will permit zeroing counters such as slug, inventory, and status. 1 Sent once each occurrence. 2 Sent once each POLL VMC Command Code VMC Data COIN TYPE OCH 4 bytes: Y1 - Y4 Yl - Y2 = Coin Enable - 2 bytes b15 b14 b13 b12 bl1 b10 b9 b8 I b7 b6 b5 b4 b3 b2 b1 bo Y1 Y2 A bit is set to indicate a coin type is accepted. For example, bit 6 is set to indicate coin type 6, bit 15 is set to indicate coin type 15, and so on. To disable the changer, disable all coin types by sending a data block containing OOOOH. All coins are automatically disabled upon reset. Y3 - Y4 = Manual Dispense Enable - 2 bytes b15 b14 b13 b12 bll b10 b9 b8 I b7 b6 b5 b4 b3 b2 bl bo Y3 Y4 A bit is set to indicate dispense enable. For example, bit 2 is set to enable dispensing of coin type 2. This command enables/disables manual dispensing using optional inventory switches. All manual dispensing switches are automatically enabled upon reset. VMC Command Code VMC Data DISPENSE ODH 1 byte: Y1 b7 b6 b5 b4 b3 b2 bl bo Y1 August 19,
30 Bits b3, b2, bl, bo indicate coin type to be dispensed. Valid codes are OH to FH to indicate coin types O to 15. Bits b7, b6, b5, b4 indicate the number of coins to be dispensed. NOTE: If two coin types have the same value, the highest coin type should be paid out first. LEVEL THREE CAPABILITIES - EXPANSION COMMAND The following describes the currently defined expansion commands. Sub-command OOH is used for a changer that has the capability of reporting model number, serial number, and so on. VMC Command Code Sub-Command Changer Response Data EXPANSION OFH OOH 33 bytes: Z1 - Z33 COMMAND (Identification) Z1 - Z3 = Z4 - Z15 = Manufacturer Code - 3 bytes Identification code for the equipment supplier. Sent as ASCII characters. Currently defined codes are listed in the NAMA document entitled The Vending Industry Data Transfer Standard, the Audit Data Dictionary section, sub-section 5, Manufacturer Codes. Serial Number - 12 bytes Factory assigned serial number. All bytes must be sent as ASCII characters, zeros (30H) and blanks (20H) are acceptable. Z16 - Z27 =Model #/Tuning Revision - 12 bytes Manufacturer assigned model number and tuning number. All bytes must be sent as ASCII characters, zeros (30H) and blanks (20H) are acceptable. Each manufacturer should include information concerning the changer tuning revision. August 19,
31 Z28 - Z29 =Software Version - 2 bytes Current software version. BCD. Must be sent in packed Z30 - Z33 =Optional Features - 4 bytes Each of the 32 bits indicate an optional features availability. If the bit is set the feature is available. Bits should be sent in descending order, i.e. bit 31 is sent first and bit O is sent last. Currently defined options are: bo - bl - b31: Alternative Payout method: This method allows changer designs that determine change payout. That is, the payout algorithm may reside in the changer instead of the VMC. Available for future use. VMC coremand Code Sub-Command VMC Data EXPANSION OFH OIH 4 bytes: Y1 - Y4 COMMAND (Feature enable) This command is used to enable each of the optional features defined in Z30-Z33 above. To enable a feature a bit is set to one. All optional features are disabled after reset. VMC Command Code Sub-command EXPANSION OFH 02H, Payout COMMAND 03H, Payout (Alternative Status Payout) VMC Data Changer Response Data Y1 None Non e 16 bytes: Z1-Z16 Y1 = Value of coins to be paid out - 1 byte This value is expressed as the number of coin scaling factors that would sum to the value. For example, in a USA system using a scaling factor of 05, if the change to be paid out is 75 cents, then Y1 August 19,
32 will equal fifteen. equal 75 cents. That is, the sum of fifteen nickels Z1 -Z16= Number of each coin type paid out - 15 bytes This is the changer s response to the last VMC payout command. Bytes are sent in ascending order of coin types. A bytes position in the string indicates the coin type. That is, byte one is the number of coins for coin type 1, byte two is the number of coins for coin type two, and so on. Unsent bytes are assumed to be zero. The changer clears payout data after an ACK response for the VMC. The VMC should paid out to Y1. compare the value of the coins NOTES: 1 ) If the changers payout is busy it will respond to the payout status command with an ACK only. 2) If no coins have been paid out, at least one zero valued data byte must be sent. Controller Command Code Sub-command Data Device Data EXPANSION COMMAND OFH 04H, Payout value poll n o n e Z1 Z1 = Changer Payout Activity - 1 byte An interval value (scaled) which indicates the amount of paid out change since the previous Payout Value Poll (or between the initial Payout command (OFH-02H) and the first Payout value Poll). An out the OOH response indicates no since the previous Payout initial Payout command). coins were paid Value Poll (or August 19,
33 An ACK only indicates that the change payout is finished. This should be followed by the Payout Status command (OFH-03H) to obtain the complete payout data. NOTE: The initial intent of this command is to determine the amount of change paid out so that the credit display can be decremented as coins are dispensed. VMC Command Code Sub-command VMC Data Changer Response Data EXPANSION COMMAND OFH FFH Y1 -Yn Z1-Zn (Diagnostics) Y1 - Yn = Z1 - Zn = Device manufacturer specific instruction for implementing various manufacturing or test modes. Y1 - Yn implies that any number of bytes can be used for the VMC data to the peripheral. Device manufacturer specific responses after receiving manufacturing or test instructions. Al - Zn implies that any number of bytes can be used for the changer response data from the peripheral. 4. Changer Non-Response Time The maximum non-response time for the changer is two seconds. 5. Changer Power Requirements The current draw for any changer must fall within the following limits. All measurements are at the minimum VMC Voltage Output. Idle mode = 200 ma. (max.) continuous Coin acceptance = 1.8 A. (max.) for up to 2 seconds Coin payout = 3.6 A. (max.) for 100 ms. with 400 ms. idle current between pulses. August 19,
34
35 Multi-Drop Bus Section 6 Bill Validator VMC/Peripheral Communication Specifications 1. Introduction This section defines the communication bytes sent and received between a Bill Validator and the VMC. The Bill Validator s address is binary. Unless stated otherwise, all information is assumed to be in a binary format. 2. VMC Commands Command Hex Code Description RESET STATUS SECURITY POLL BILL TYPE 30H 31H 32H 33H 34H Command for bill validator to self-reset. Request for bill validator set-up status Sets Validator Security Mode Request for Bill Validator activity Status, Indicates Bill Type enable or disable. Command is followed by set-up data. See command format. ESCROW 35H Sent by VMC to a bill in escrow. indicate action for STACKER 36H Indicates stacker number of bills. full and the EXPANSION COMMAND 37H Command to allow addition of features and future enhancements. Level 1 bill Validators must support this command. NOTE: The command. August 19, 1994 expansion command is always followed by a sub- 6.1
36 3. VMC Command Format VMC Command Code VMC Data RESET 30H No data bytes This command is the vehicle that the VMC should use to tell the validator that it should return to its default operating mode. It should reject any bills in the validation process, return any bills in the escrow position, and disable all other activity until otherwise instructed by the VMC. VMC Command Code Validator Response Data STATUS 31H 27 bytes: Z1 - Z27 Z1 = Z2 - Z3 = Z4 - Z5 = Bill Validator Feature Level - 1 byte Indicates current feature level of the bill validator. Currently defined level is one. Country Code - 2 bytes The International Telephone Code for the country that the Validator is set-up for. Sent in packed BCD. For example, the code for the USA is 00 OIH Bill Scaling Factor - 2 bytes All accepted bill values must be evenly divisible by this number. For example, this could be set to O064H for the USA. Z6 = Decimal Places - 1 byte Indicates the number of decimal places on a credit display. For example, this could be set to 02H for the USA. Z7 - Z8 = Z9 - Zl0 = Stacker Capacity - 2 bytes Indicates the number of bills that the stacker will hold. For example, 400 bill capacity = 0190H Bill Security Levels -2 bytes Indicates the security level for bill types O to 15. Since not all Validators support multiple security levels, Validators that do not have this feature must report a high security level. August 19, 1994
37 Zll = Z12 - Z27 Escrow/No Escrow - 1 byte Indicates the escrow capability of the bill validator. If Z11 = OOH, the bill validator does not have escrow capability. If Z11 = FFH, the bill validator has escrow capability. =Bill Type Credit - 16 bytes Indicates the value of the bill types O to 15. Values must be sent in ascending order. This number is the bill s monetary value divided by the bill scaling factor. Unused bill types are sent as OOH. Unsent bill types are assumed to be zero. FFH bills are assumed to be vend tokens. VMC Command Code VMC Data SECURITY 32H 2 Bytes: Y1 - Y2 Y1 - Y2 = Bill Type(s) - 2 bytes b15 b14 b13 b12 bll b10 b9 b8 I b7 b6 b5 b4 b3 b2 bl bo Y1 Y2 A bit is set to indicate the type of bill(s) which are set to a high security level. Validators that do not support dual security levels should report a high security level. VMC Command Code Validator Response Data POLL 33H 16 bytes: Z1 - Z16 Z1 - Z16 = Bill Validator Activity - 16 bytes Indicates the validator activity, for example, the type and number of bills accepted, and stacker position. If there is nothing to report, the validator should send only an ACK. Otherwise, the only valid responses are: August 19, 1994
38 Bills Accepted: Indicates the type and number of bills accepted and stacker status. Byte 1 (1yyyxxxx) yyy =Bill Routing; 000: BILL STACKED 001: ESCROW POSITION 010: BILL RETURNED 011: NOT USED 100: DISABLED BILL xxxx = Bill Type (O to 15) NOTE: These responses should be used to add or subtract credit. Status: August 19, 1994 ( ) = ( ) = ( ) = ( ) = ( ) = ( ) = ( ) = Defective Motor 3 - One of the motors has failed to perform its expected assignment. Sensor Problem 3 - One of the sensors has failed to provide its response. Validator Busy 2 - The validator is busy and can not answer a detailed command right now. ROM Checksum Error 3 - The Validators internal checksum does not match the calculated checksum. Validator Jammed 3 - A bill(s) has jammed in the acceptance path. Validator was reset l - The validator has been reset since the last POLL. Bill Removed l - A bill in the escrow position has been removed by an unknown means. A BILL RETURNED message should also be sent. 6.4
39 ( ) = Cash Box out of position 3 - The validator has detected the cash box to be open or removed. ( ) = Unit Disabled 2 - The validator has been disabled, by the VMC or because of internal conditions. ( ) = Invalid Escrow request l - An ESCROW command was requested for a bill not in the escrow position. ( ) = Bill Rejected l - A bill was detected, but rejected because it could not be identified. (Ol0xxxxxx) = Number of attempts to input a bill while validator is disabled. 1 NOTE: The validator may send several of one type activity up to 16 bytes total. 1 Sent once each occurrence. 2 Sent once each POLL 3 Sent once each occurrence. The unit is then disabled until the condition is removed. Validator will respond with unit disabled until repaired or replaced. VMC Command Code VMC Data BILL TYPE 34H 4 bytes: Y1 - Y4 Y1 - Y2 = Bill Enable - 2 bytes Indicates what type of bills are accepted. b15 b14 b13 b12 bll b10 b9 b8 I b7 b6 b5 b4 b3 b2 bl bo Y1 Y2 Bill types are O to 15. acceptance of bill type. A bit is set to indicate NOTE : Sending OOOOH disables the bill validator. August 19,
40 Y3 - Y4 = Bill Escrow Enable: b15 b14 b13 b12 bll b10 b9 b8 I b7 b6 b5 b4 b3 b2 bl bo Y3 Y4 Bill types are O to 15. A bit is set to indicate enable of escrow for a bill type. NOTE: disabled. On power-up or reset all bill acceptance and escrow are VMC Command Code VMC Data ESCROW 35H 1 byte: Y1 Y1 = Escrow status - 1 byte If Y1 = O; If Y1 = xxxxxxxl ; Return bill in the escrow position. Stack the bill ( x indicates don t care ) NOTE: After an ESCROW command the bill validator should respond to a POLL command with the BILL STACKED, BILL RETURNED, or INVALID ESCROW message within 30 seconds. If a bill becomes jammed in a position where the customer may be able to retrieve it, the bill validator should send a BILL RETURNED message.. VMC Command Code Validator Response Data STACKER 36H 2 bytes: Z1 - Z2 Indicates stacker full condition and the number of bills in the stacker. Byte 1 Byte 2 (Fxxxxxxx) (xxxxxxxx) F = 1 if stacker is full, O if not. xxxxxxxxxxxxxxx = The number of bills in the stacker. August 19,
41 VMC Command Code Sub-Command Validator Response Data EXPANSION 37H OOH 29 bytes: Z1 - Z29 COMMAND (Identification) Z1 - Z3 = Z4 - Z15 = Z16 - Z27 Z28 - Z29 Manufacturer Code - 3 bytes Identification code for the equipment supplier. Sent as ASCII characters. Currently defined codes are listed in the NAMA document entitled The Vending Industry Data Transfer Standard, the Audit Data Dictionary section, sub-section 5, Manufacturer Codes. Serial Number - 12 bytes Factory assigned serial number. All bytes must be sent as ASCII characters, zeros (30H) and blanks (20H) are acceptable. =Model #/Tuning Revision - 12 bytes Manufacturer assigned model number. All bytes must be sent as ASCII characters, zeros (30H) and blanks (20H) are acceptable. =Software Version - 2 bytes Current software version. Must be sent in packed BCD. VMC Command Code Sub -command VMC Data Changer Response Data EXPANSION COMMAND OFH Y1-Yn Z1-Zn (Diagnostics) Y1 - Yn = Device manufacturer specific instruction for implementing various manufacturing or test modes. Y1 - Yn implies that any number of bytes can be used for the VMC data to the peripheral. Z1 - Zn = Device manufacturer specific responses after receiving manufacturing or test instructions. Al - Zn implies that any number of bytes can be used for the changer response data from the peripheral. August 19,
42 4. Bill Validator Non-Response Time The maximum non-response time for the bill validator is five seconds. 5. Bill Validator The current draw following limits. Voltage Output. Idle mode Bill transport Power Requirements for any bill validator must fall within the All measurements are at the minimum VMC = 200 ma. (avg.) continuous = 2.5 A. (max. ) up to 10 seconds August 19,
43 Multi-Drop Bus Section 7 Card Reader VMC/Peripheral Communication Specifications 1. Introduction This section defines the communications bytes sent and received between the card reader and the Vending Machine Controller (VMC). The card reader address is OOO1Ob. Unless otherwise stated, all monetary values used by the card reader and the VMC will be sixteen bit, unsigned binary numbers. The numbers will be sent most significant byte first and scaled using the parameters provided by the card reader s READER CONFIGURATION DATA response. 2. State Definitions MDB card readers may be viewed as state machines. are as follows: These states 1) Inactive 2) Disabled 3) Enabled 4) Session Idle 5) Vend Inactive This is the state of the reader at power up or after a reset. While in the Inactive state, cards will NOT be accepted for vending purposes. The reader cannot leave this state until all SETUP information is received from the VMC. Disabled The reader automatically enters this state from the Inactive state when it has received all SETUP information from the VMC. It will also enter the Disabled state from the Enabled state when it receives the READER DISABLE command. While in the Disabled state, cards will NOT be accepted for vending purposes. The reader will remain in this state until either a READER ENABLE command is received (when it will enter the Enabled state) or a RESET is received (when it will enter the Inactive state). For power management purposes, current consumption will not exceed the idle mode specification during the disabled state. August 19,
44 Enabled In this state, cards may be used for MDB transactions. The reader will remain in this state until a valid card is read (when it will enter the Session Idle state), a READER DISABLE command is received (when it will return to the Disabled state) or a RESET is received (when it will enter the Inactive state). Session Idle In the Enabled state, when a valid card is processed, the reader will issue a BEGIN SESSION response to a VMC POLL and enter the Session Idle state. This indicates that the reader is available for vending activities. The only structured exit from the Session Idle state is through the SESSION COMPLETE message from the VMC. The SESSION COMPLETE command will cause the reader to respond with an END SESSION message and enable/disable itself appropriately. Vend commands will cause the reader to leave the Session Idle state and enter the Vend state when products are selected and purchased. Vend This state is entered from the Session Idle state upon reception of a VEND REQUEST message from the VMC. The entire Vend state is an uninterruptible command/response sequence. The reader will return to the Session Idle state upon completion of this sequence. 3. Command Protocol After the VMC has issued a command, no new commands may be issued until all data generated in response to that command has been received from the reader. The complete response may be ACK only (e.g. the READER ENABLE command). Alternatively, it may consist of an informational response (e.g. READER CONFIGURATION DATA). The reader may provide an informational response in two ways. It may respond immediately with the requested data; or the reader may AC - K the - VMC command. If ACKed, the - VMC must issue POLLS until the reader responds with the requested data, or until the Application Maximum Response Time (defined in READER CONFIGURATION response) has elapsed. August 19, 1994
45 Below are the uninterpritble commands which require an informational response, and their associated responses: SETUP/CONFIGURATION DATA ==> READER CONFIGURATION DATA EXPANSION/REQUEST ID ==> PERIPHERAL ID READER CANCEL => CANCELLED VEND REQUEST... VEND CANCEL ==> VEND DENIED* VEND REQUEST ==> VEND DENIED* VEND REQUEST ==> VEND APPROVED ==> VEND SUCCESS* VEND REQUEST ==> VEND APPROVED ==> VEND FAILURE* SESSION COMPLETE ==> END SESSION *These VEND COMMAND/response sequences constitute the Vend state. Any command may be issued by the VMC at anytime providing the above command protocol is observed. There are four exceptions to this rule: 1) 2) 3) 4) VEND COMMAND/response sequences may only be initiated in the Session Idle state. The VMC may issue a VEND CANCEL command after issuing a VEND REQUEST, but before receiving a VEND APPROVED/DENIED response. In this case the reader will issue a VEND DENIED response to satisfy the original VEND REQUEST response requirement. The reader may issue DISPLAY REQUESTS in response to POLLS at any time, if the VMC s display is available for use. The RESET command is allowed at any time; it is not subject to any restrictions. If a VMC command is received by the reader which is unexecutable in its present state or while the reader is in one of the preceding uninterruptible sequences, the following will occur: 1) The reader will ACK the offending command (no data August 19, *3
46 Multi-Drop Bus response will be forthcoming). The reader will respond the next POLL with the COMMAND OUT OF SEQUENCE response (OBh). to 2) Alternatively, the reader may respond with a NAK or not respond in response to an out of sequence command. Multi-Message Response Format The multi-message response format permits the card reader to send multiple messages in response to a single command. Because all messages are of a fixed length, there is no confusion determining where one message ends and the next message begins. (The total message length is subject to the 36 byte limit imposed by Section 2 of this standard. ) For example, if a reader fails to correctly write a card after a VEND REQUEST, it may need to report: 1) VEND DENIED 2) MALFUNCTION/ERROR subcode 07h 3) SESSION CANCEL REQUEST The multi-message response (hex) would look like this: The first byte above (marked 1) is the VEND DENIED message. The next two bytes (marked 2) are the MALFUNCTION/ERROR message. The third and final message is the CANCEL SESSION REQUEST (marked 3). An eight bit checksum with the mode bit set (marked 4) finishes the message. It is important to note that the controller must service the messages in the order in which they are received. This is necessary to insure that command protocol is maintained. August 19,
47 Coin Mechanism Escrow Return Actions The reaction of the VMC to the coin mechanism escrow return will vary depending upon the state of the system at the time it is pressed. 1 ) In the Enabled state, the VMC should send a READER CANCEL command to the card reader. This allows the user to abort a pre-approved on-line authorization request. 2) In the Session Idle state, the VMC should send a SESSION COMPLETE command to the card reader. This will return the reader to the Enabled state. 3 ) In the Vend state, before the reader has sent a VEND APPROVED or a VEND DENIED, the VMC should send a VEND CANCEL command to the card reader. This will cancel the vend and cause the reader to refund the reader if necessary. 4 ) In all other cases, no message is sent from the VMC to the card reader. August 19,
48 TABLE 1 : CONTROLLER COMMANDS VMC COMMANDS RESET SETUP POLL CODE 10h 1lh 12h CONTROLLER DATA No Data OOh - Config. Data Olh - Max/Min Prices No Data CARD READER RESPONSE PAGE PAGE 7.7 No Data Olh - Reader Config. Data 7*8 7.9 No Data h - Session Cancel Rqst h - Vend Approved 7*12 06h - Vend Denied 7*12 I VEND READER EXPANSION 13h 14 h 17h OOh - Vend Request Olh - Vend Cancel 02h - Vend Success 03h - Vend Failure 04h - Session Complete Oh - Disable 0lh - Enable 02h - Cancel OOh - Request ID FEh - Diagnostics OBh - Cmd Out of Seq I 7 15 FFh - Diagnostic Response h - Vend Approved h - Vend Denied h - Vend Denied No Data No Data h - End Session No Data 7.19 No Data h - Cancel led O 09h - Peripheral ID 7.2O 7.21 FFh - Diagnostic Response NOTE: Reader responses which are part of request/response sequences are listed more than once in the above table, since the reader may respond either immediately to the request (within 5 milliseconds) or to a later POLL. August 19, 1994
49 4. Card Reader Command/Response Formats VMC Command Code VMC Data RESET 10h No data bytes If this command is received by a card reader it should terminate any ongoing transaction (with a refund, if appropriate), eject the card (if applicable), and go to the Inactive state. The VMC must follow the RESET command with all SETUP commands and a READER ENABLE command to enable vending transactions. VMC Command Code/Sub-Command VMC Data SETUP/ 11 h/o O h 5 bytes: Y1 - Y5 CONFIGURATION DATA Con fig VMC Cols Rows Disp Setup Data Feature On On Info (1lh) (OOh) Level Disp Disp Y1 Y2 Y3 Y4 Y5 Y1 = CONFIGURATION DATA. Y2 = Y3 = Y4 = Y5 = VMC is sending its configuration data to reader. VMC Feature Level. Indicates the feature level of the VMC. highest feature level is 01. Currently the Columns on Display. The number of columns on the display. Set to OOh if the display is not available to the card reader. Rows on Display. The number of rows on the display. Display Information OOh: Numbers, upper case letters, blank and decimal point. 01h-001: Full ASCII. 02h-FFh: Unassigned. August 19,
50 Card Reader Respose Code Card Reader Data READER CONFIGURATION DATA 01 h 8 bytes: Z1 - Z8 Reader Card Country Country Scale Decimal Appl Misc Config Feature Code Code Low Factor Places Max Optior Data (Olh) Level High Z4 Z5 Z6 Resp Z8 Z1 Z2 Z3 Time Z7 Z1 = READER CONFIGURATION DATA. Z2 = Z3 - Z4 = Z5 = Z6 = Indicates the card reader is responding to a SETUP/ CONFIGURATION DATA request from the VMC. Card Reader Feature Level. The feature level of the card reader. highest feature level is 01. Country Code - packed BCD. Currently the International Telephone Code for the country in which the card reader is set-up for. For example, the USA code is Use FFFFh if the country code is unknown. Scale Factor. The multiplier used to scale all monetary values transferred between the VMC and the card reader. Decimal Places. The number of decimal places used to communicate monetary values between the VMC and the reader. All pricing information sent between the VMC and the card reader is scaled using the scale factor and decimal places. This corresponds to: Actual Price = P*X*10ˆ-Y Z7 = August 19, 1994 where P is the scaled value sent in the price bytes, and X is the scale factor, and Y is the number of decimal places. For example, if there are 2 decimal places and the scale factor is 5, then a scaled price of 7 will mean an actual price of Application Maximum Response Time - seconds. The maximum length of time that a reader will require to provide a response to any command from the VMC. 7.8
51 Multi-Drop Bus Z8 = Miscellaneous Options - xxxxxyyy. xxxxx = unused yyy = option bits bo=o: The card reader is NOT capable of restoring funds to the user s card or account. Do not request refunds. bo= 1: The card reader is capable of restoring funds to the user s card or account. Refunds may be requested. bl =0: The card reader is NOT multivend capable. Terminate session after each vend. bl=l: The card reader is multivend capable. Multiple items may be purchased within a single session. b2=o: The card reader does NOT have a display. b2=l: The card reader does have its own display. VMC Command C ode/sub - Command VMC Data SETUP/ 11 h/o 1 h 5 bytes: Y1 - Y5 MAX/MIN PRICES Max/Min Max Min Setup Prices Price Price (1lh) (01 h) Y1 Y2-Y3 Y4-Y5 Y1 = MAX/MIN PRICES. Indicates the VMC is sending the price range to the read e r. Y2 - Y3 = Y4 - Y5 = Maximum Price - scaled. This information should be sent as soon as the VMC prices have been established and any time there is a change in the maximum price. If the VMC does not know the maximum price, FFFFh should be sent. Minimum Price - scaled. This information should be sent as soon as the VMC prices have been established and any time there is a change in the minimum price. If the VMC does not know the minimum price, OOOOh should be sent. August 19,
52 VMC Command Code VMC Data POLL 12h No data bytes ---- t Poll I I (12h) I The POLL command is used by the VMC to obtain information from the card reader. This information may include user actions (CANCEL SESSION REQUEST), hardware malfunctions (MALFUNCTION /ERROR), software malfunctions (COMMAND OUT OF SEQUENCE) or information explicitly requested by the controller (READER CONFIGURATION DATA). An ACK response indicates that no error states exist, and either no information request is pending or pending information is not yet ready for transmission. In addition to an ACK, the VMC may receive the following POLL responses from the card reader. Card Reader Response Code Card Reader Data JUST RESET OOh 1 byte: Z1 card reader has been reset. Code Card Reader Data READER CONFIGURATION DATA Olh 8 bytes: Z1 - Z8 Reader Con fig Info (Olh) Z1 See full Card Country Country Scale Decimal Appl Misc Feature Code Code Factor Places Max Options Level High Low Resp Time Z2 Z3 Z4 Z5 Z6 Z7 Z8 explanation under SET UP/CONFIGURATION Command. August 19,
53 Card Reader Response Code Card Reade r Data DISPLAY REQUEST 02h Up to 34 bytes: Z1-Z34 Display Display Display Request Time Data (02h) I Z1 I Z2 I Z3-Z34 I Z1 = DISPLAY REQUEST. Z2 = Z3 - Z34 = The card reader is requesting a message to be displayed on the VMC s display. Display Time second units. The requested display time. Either the VMC or the card reader may overwrite the message before the time has expired. Display Data - ASCII. The message to be displayed. Formatting (leading and/or trailing blanks) is the responsibility of the card reader. The number of bytes must equal the product of Y3 and Y4 in the SETUP/CONFIGURATION command, up to a maximum of 32 bytes Response C ode Card Reader Data Card Reader BEGIN SESSION 03 h 3 bytes: Z1 - Z3 Z2 - Z3 = Allow a patron to make a selection, but do not dispense product until funds are approved. Funds Available - scaled. a. Lesser of the user s card or account balance or FFFEh units. b. Not yet determined - FFFFh. August 19,
54 Card Reader Response Code Ca rd Reader Data SESSION CANCEL REQUEST 04 h 1 byte: Z1 = SESSION CANCEL REQUEST. The card reader is requesting the VMC to cancel the session. The VMC should initiate an eventual SESSION COMPLETE. Card Reader Response Code Card Reader Data VEND APPROVED 05 h 3 bytes: Z1 - Z3 Vend Approved (05h) Z1 Z1 = Z2 - Z3 = Allow the selected product to be dispensed. Vend Amount - scaled. This is the amount deducted from account. This may not match the VEND REQUEST command; it may discounted. the user s card or amount specified in be surcharged or the Card Reader Response C ode Card Reader Data VEND DENIED 06h 1 byte: Z1 Vend Denied (06h) Z1 Z1 = VEND DENIED. Approval denied for the patron s selection. Do not dispense any products. August 19,
55 Card Reade r Response Code Card Reader Data END SESSION 07 h 1 byte: Z1 End Session (07h) Z1 Z1 = END SESSION. This command is issued in response to a SESSION COMPLETE command. The END SESSION response indicates the reader has returned to the Enabled or Disabled state, whichever is appropriate. Card Reader Res ponse Code Card Reader Data CANCELLED 08h 1 byte: Z1 PERIPHERAL ID 09h 30 bytes: Z1 - Z30 Peripheral Manufacture Serial Model Software ID Code Number Number Version (09h) Z1 Z2-Z4 Z5-Z16 Z17-Z28 Z29-Z30 Z1 = PERIPHERAL ID. Z2 - Z4 = Reader is sending peripheral ID information. Manufacturer Code - ASCII. Identification code for the equipment supplier. Currently defined codes are listed in the NAMA document entitled The Vending Industry Data Transfer Standard, the Audit Data Dictionary section, sub-section 5, Manufacturer Codes. August 19,
56 Z5 - Z16 = Serial Number - ASCII. Factory assigned serial number. Z17 - Z28 = Model Number - ASCII. Manufacturer assigned model number. Z29 - Z30 = Software Version - packed BCD. Current software version. Card Reader Response C ode Card Reader Data MALFUNCTION/ OAh 2 bytes: Z1 - Z2 ERROR Malfunction/ Error (OAh) Z1 Z1 = Z2 = Error Code Z2 MALFUNCTION/ERROR. The card reader is reporting a malfunction or error. Error Code - xxxxyyyy. xxxx = 0000: 0001 : 0010: 001 1: 0100: 0101: 01 10: 011 1: 1000: 1001 : 1010: 1011 : : Card Error l Invalid Card l Tamper Error l Manufacturer Defined Error l Communications Error 2 Reader Requires Service 2 Unassigned 2 Manufacturer Defined Error 2 Reader Failure 3 Communications Error 3 Card Jammed 3 Manufacturer Defined Error 3 Unassigned 1 Transient 2 error - Reported once Non-transient error - Reported every POLL until cleared. Reader still functional. August 19,
57 3 Non-transient error - Reported every POLL until cleared. Reader not presently functional. yyyy = Manufacturer defined subcode Transient Error Handling The error will be reported to the VMC until it has been Acknowledged. The error state will be cleared in the reader, and normal operations will continue. Non-transient Error Handling The error will be reported to the VMC at each POLL as long as it exists. If the reader is still functional, multi-message responses will allow normal responses in addition to the error report. Card Reader Response Code Card Reader Data COMMAND OUT OF SEQUENCE OBh 1 byte: Z1 Command out of Sequence (OBh) Z1 Z1 = COMMAND OUT OF SEQUENCE. The card reader has received a command that is not executable in its current state or which violates one of the uninterruptible sequences. The offending command may be ACKnowledged, but not acted upon by the reader. Card Reader Response Code Card Reader Data DIAGNOSTICS RESPONSE FFh up to 35 bytes: Z2 - Zn Z2 - Zn User Defined Data. The data portion of this response is defined by the manufacturer and is not part of this document. August 19,
58 VMC Command Code/Sub-Command VMC Data VEND REQUEST 13h/00h 5 bytes: Y1 - Y5 Vend Item Item Vend Request Price Number (13h) (OOh) Y1 Y2-Y3 Y4-Y5 Y1 = VEND REQUEST. The patron has made a selection. The VMC is requesting vend approval from the card reader before dispensing the product. Y2 - Y3 = Item Price - scaled. The price of the selected product. Y4 - Y5 = Item number. The item number of the selected defined by the manufacturer, and undefined or not implemented. product. This number is set to FFFFh for August 19,
59 Multi-Drop Bus 1 VMC Command Code/S u b- Command VMC Data VEND CANCEL 13 h/o 1 h 1 byte: Y1 YI = VEND CANCEL. This command can be issued by the VMC to cancel a VEND REQUEST command before a VEND APPROVED/DENIED has been sent by the card reader. The card reader will respond to VEND CANCEL with a VEND DENIED and return to the Session Idle state. Card Reader Response Code Card Reader Data VEND DENIED 06h 1 byte: Z1 VMC Command Cod e/s u b - Command VMC Data VEND SUCCESS 13 h/o 2 h 3 byte: Y1-Y3 Y2 - Y3 = The selected product has been successfully dispensed. Item number. The item number of the selected product. This number is defined by the manufacturer, and set to FFFFh for undefined or not implemented. NOTE: A reset between VEND APPROVED and VEND SUCCESS shall be interpreted as a VEND SUCCESS. August 19,
60 VMC Command Code/S u b - Command VMC Data VEND FAILURE 13 h/o 3 h 1 byte: Y1 Y1 = VEND FAILURE. A vend has been attempted at the VMC but a problem has been detected and the vend has failed. The product was not dispensed. Funds should be refunded to user s account. VMC Command Code/S u b- Command VMC Data SESSION COMPLETE 13 h/o 4 h 1 byte: Y1 This tells the card reader that the session is complete to return to the appropriate Enabled or Disabled state. SESSION COMPLETE is part of a command/response sequence that requires an END SESSION response from the reader. and See full explanation under POLL Command. VMC Command Cod e/s u b - Command VMC Data READER DISABLE 14 h/o Oh 1 byte: Y1 Reader Disable (14h) (OOh) Y1 Y1 = READER DISABLE. August 19,
61 This informs the card reader that it has been disabled, i.e. it should no longer accept a patron s card for the purpose of vending. Vending activities may be re-enabled using the READER ENABLE command. The card reader should retain all SETUP information. NOTE: Any transaction in progress will not be affected and should continue to its normal completion. VMC Command C ode/sub - Command VMC Data READER ENABLE 14 h/o 1 h 1 byte: Y1 This informs the card reader that is has been enabled, i.e. it should now accept a patron s card for vending purposes. This command must be issued to a reader in the Disabled state to enable vending operations. VMC Command Code/Sub - Command VMC Data READER CANCEL 14 h/o 2 h 1 byte: Y1 Y1 = READER CANCEL. This command is issued to abort card reader activities which occur in the Enabled state. It is the first part of a command/response sequence which requires a CANCELLED response from the reader. Card Reader Response Code Card Reader Data CANCELLED 08h 1 byte: Z1 Cancelled August 19,
62 VMC Command C o d e/sub - C o m m and VMC Data EXPANSION/ 17 h /00 h 30 bytes: Y1-Y30 REQUEST ID ---- Expansion Request Manufacture Serial Model Software ID Code Number Number Version (17h) (OOh) Y1 Y2-Y4 Y5-Y16 Y17-Y28 Y29-Y30 Y1 = REQUEST ID. Y2 - Y4 = The VMC is requesting card reader identification information. The information included above (Y2-Y30) provides the card reader with VMC identification information. Manufacturer Code - ASCII. Identification code for the equipment supplier. Currently defined codes are listed in the NAMA document entitled The Vending Industry Data Transfer Standard, the Audit Data Dictionary section, sub-section 5, Manufacturer Codes. Y5 - Y16 = Serial Number - ASCII. Factory assigned serial number. Y17 - Y28 = Model Number - ASCII. Manufacturer assigned model number. Y29 - Y30 = Software Version - packed BCD. Current software version. Card Reader Response Code Card Reader Data PERIPHERAL ID 09h 30 bytes: Z1 - Z30 Peripheral Manufacture Serial Model Software ID Code Numb e r Numb e r Version (09h) Z1 Z2-Z4 Z5-Z16 Z17-Z28 Z29-Z30 See full explanation under POLL Command. August 19,
63 Multi-Drop Bus VMC Command Code/Sub-Command VMC Data EXPANSION/ 17h/FFh up to 34 bytes: Y1-Yn DIAGNOSTICS I Expansion (17h) Y1 = Y2 - Yn = Diagnostics (FFh) I Y1 DIAGNO User Defined Y2-Yn STICS. Device manufacturer specific instruction for implementing various manufacturing or test modes. User Defined Data. The data portion of this command is defined by the manufacturer and is not part of this document. Card Reader Response Code Card Reader Data DIAGNOSTICS RESPONSE FFh up to 35 bytes: Z2 - Zn Diagnostics User Response Defined (FFh) Z1 Z2-Zn See full explanation under POLL Command. 5. Non-Response Time The maximum non-response time for a card reader is 5 seconds. This is the maximum time for which a card reader will not respond to a command or a POLL with ACK, NAK or a message. 6. Card Reader Power Requirements The current draw for any card reader must fall within the following limits. All measurements are at the minimum VMC Voltage Output. Idle mode = 300 ma. (avg. ) continuous Transport or Read/Write cycle =1.5 50% maximum duty cycle up to 5 seconds August 19,
64
HOST Embedded System. SLAVE EasyMDB interface. Reference Manual EasyMDB RS232-TTL. 1 Introduction
Reference Manual EasyMDB RS232-TTL 1 Introduction This document explains how to use the interface EasyMDB RS232-TTL and describe the connections and the necessary commands for communicating with Cash System
DS1721 2-Wire Digital Thermometer and Thermostat
www.dalsemi.com FEATURES Temperature measurements require no external components with ±1 C accuracy Measures temperatures from -55 C to +125 C; Fahrenheit equivalent is -67 F to +257 F Temperature resolution
OVERVIEW OF VENDING MACHINE
OVERVIEW OF VENDING MACHINE INTERFACES 1. Introduction This document is intended to be a brief guide to vending machine interfaces, it assumes the reader has little knowledge of interfaces and is looking
Audit Pro 2000 Operational Manual For use with C2000 v3.x, v4.x or v5.x
Audit Pro 2000 Operational Manual For use with C2000 v3.x, v4.x or v5.x Document #101-0048 1 10/17/06 TABLE OF CONTENTS I. INTRODUCTION... 4 II. INSTALLATION... 5 III. PROGRAMMING... 6-13 1 - PROGRAM PAYOUTS...
Implementation Guide. SAS Serial Protocol. for. Montana Department of Justice Gambling Control Division. October 22, 2012. Version 1.4.
Implementation Guide for SAS Serial Protocol Montana Department of Justice Gambling Control Division October 22, 2012 Version 1.4.1 Montana SAS Implementation Guide Page 2 Table of Contents 1 Introduction...
Appendix B RCS11 Remote Communications
Appendix B RCS11 Remote Communications B.1 Host Computer Remote Communications Control and status messages are conveyed between the RCS11 and the host computer using packetized message blocks in accordance
DS1621 Digital Thermometer and Thermostat
Digital Thermometer and Thermostat www.dalsemi.com FEATURES Temperature measurements require no external components Measures temperatures from 55 C to +125 C in 0.5 C increments. Fahrenheit equivalent
WA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide
WA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide Version 2.1, 4/2010 Disclaimer While every effort has been made to ensure that the information in this guide is accurate
PACKAGE OUTLINE DALLAS DS2434 DS2434 GND. PR 35 PACKAGE See Mech. Drawings Section
PRELIMINARY DS2434 Battery Identification Chip FEATURES Provides unique ID number to battery packs PACKAGE OUTLINE Eliminates thermistors by sensing battery temperature on chip DALLAS DS2434 1 2 3 256
Modbus Protocol. PDF format version of the MODBUS Protocol. http://www.http://www.modicon.com/techpubs/toc7.html. The original was found at:
Modbus Protocol PDF format version of the MODBUS Protocol The original was found at: http://www.http://www.modicon.com/techpubs/toc7.html (In case of any discrepancies, that version should be considered
The Answer to the 14 Most Frequently Asked Modbus Questions
Modbus Frequently Asked Questions WP-34-REV0-0609-1/7 The Answer to the 14 Most Frequently Asked Modbus Questions Exactly what is Modbus? Modbus is an open serial communications protocol widely used in
ESPA 4.4.4 Nov 1984 PROPOSAL FOR SERIAL DATA INTERFACE FOR PAGING EQUIPMENT CONTENTS 1. INTRODUCTION 2. CHARACTER DESCRIPTION
PROPOSAL FOR SERIAL DATA INTERFACE FOR PAGING EQUIPMENT CONTENTS 1. INTRODUCTION 2. CHARACTER DESCRIPTION 2.1 CHARACTER STRUCTURE 2.2 THE CHARACTER SET 2.3 CONTROL CHARACTERS 2.3.1 Transmission control
DS1621 Digital Thermometer and Thermostat
www.maxim-ic.com FEATURES Temperature measurements require no external components Measures temperatures from -55 C to +125 C in 0.5 C increments. Fahrenheit equivalent is -67 F to 257 F in 0.9 F increments
RS-485 Protocol Manual
RS-485 Protocol Manual Revision: 1.0 January 11, 2000 RS-485 Protocol Guidelines and Description Page i Table of Contents 1.0 COMMUNICATIONS BUS OVERVIEW... 1 2.0 DESIGN GUIDELINES... 1 2.1 Hardware Design
OPERATION & SET-UP MANUAL. 5400 Series Coin Operated Controllers. USA Market
OPERATION & SET-UP MANUAL 5400 Series Coin Operated Controllers USA Market 705 Progress Ave. Building 63 Toronto ON Canada M1H 2X1 ITC SYSTEMS 800 Fee Fee Rd. St Louis MO USA 63043 Document: 5400_USA_rev1_7.doc
A.u.S. Spielgeräte GmbH NV10 Bank Note Validating System. The Future of Smiley Bank Note Handling. Operations Manual GA333-3
A.u.S. Spielgeräte GmbH NV10 Bank Note Validating System The Future of Smiley Bank Note Handling Operations Manual GA333-3 CONTENTS CONTENTS... 2 Change History... 3 1: Introduction... 4 2: Scope of Document...
Software User Guide UG-461
Software User Guide UG-461 One Technology Way P.O. Box 9106 Norwood, MA 02062-9106, U.S.A. Tel: 781.329.4700 Fax: 781.461.3113 www.analog.com ezlinx icoupler Isolated Interface Development Environment
4511 MODBUS RTU. Configuration Manual. HART transparent driver. No. 9107MCM100(1328)
4511 MODBUS RTU Configuration Manual HART transparent driver No. 9107MCM100(1328) 9107 CONTENTS Introduction... 3 Modbus basics... 3 Modbus RTU... 3 Supported Function Codes... 3 Modbus Parameters and
Data Acquisition Module with I2C interface «I2C-FLEXEL» User s Guide
Data Acquisition Module with I2C interface «I2C-FLEXEL» User s Guide Sensors LCD Real Time Clock/ Calendar DC Motors Buzzer LED dimming Relay control I2C-FLEXEL PS2 Keyboards Servo Motors IR Remote Control
Modbus Communications for PanelView Terminals
User Guide Modbus Communications for PanelView Terminals Introduction This document describes how to connect and configure communications for the Modbus versions of the PanelView terminals. This document
In-Vehicle Networking
In-Vehicle Networking SAE Network classification Class A networks Low Speed (
NB3H5150 I2C Programming Guide. I2C/SMBus Custom Configuration Application Note
NB3H550 I2C Programming Guide I2C/SMBus Custom Configuration Application Note 3/4/206 Table of Contents Introduction... 3 Overview Process of Configuring NB3H550 via I2C/SMBus... 3 Standard I2C Communication
Virtual Integrated Design Getting started with RS232 Hex Com Tool v6.0
Virtual Integrated Design Getting started with RS232 Hex Com Tool v6.0 Copyright, 1999-2007 Virtual Integrated Design, All rights reserved. 1 Contents: 1. The Main Window. 2. The Port Setup Window. 3.
DeviceNet Communication Manual
DeviceNet Communication Manual Soft-Starter Series: SSW-07/SSW-08 Language: English Document: 10000046963 / 00 03/2008 Summary ABOUT THIS MANUAL... 5 ABBREVIATIONS AND DEFINITIONS... 5 NUMERICAL REPRESENTATION...
CipherLab 5100 Time Attendance Utility Manual
CipherLab 5100 Time Attendance Utility Manual K:\Products\Product Technical\BI\BI-PC5100T\CipherLab5100TimeAttendnaceUtilityManual0707-process.doc Page 1 / 13 1 Login A popup form as follows will appear
Serial Communications / Protocol in AirTest Products
Serial Communications / Protocol in AirTest Products General The standard sensor has two different ways of serial communication with sensor s peripherals and the outside world. One is through the UART
DeviceNet Bus Software Help for Programming an Allen Bradley Control System
FBP FieldBusPlug V7 DeviceNet Bus Software Help for Programming an Allen Bradley Control System DeviceNet Software Help for Programming an Allen Bradley Control System Contents Page General Purpose...
Telegrams for Operating/Configuring the LMS 2xx Laser Measurement Systems Firmware Version V2.10/X1.14
Telegrams for Operating/Configuring the LMS 2xx Laser Measurement Systems Firmware Version V2.10/X1.14 T E L E G R A M L I S T I N G Telegram listing LMS 2xx Laser Measurement Systems Software Status:
FM75 Low-Voltage Two-Wire Digital Temperature Sensor with Thermal Alarm
Low-Voltage Two-Wire Digital Temperature Sensor with Thermal Alarm Features User Configurable to 9, 10, 11 or 12-bit Resolution Precision Calibrated to ±1 C, 0 C to 100 C Typical Temperature Range: -40
plc numbers - 13.1 Encoded values; BCD and ASCII Error detection; parity, gray code and checksums
plc numbers - 3. Topics: Number bases; binary, octal, decimal, hexadecimal Binary calculations; s compliments, addition, subtraction and Boolean operations Encoded values; BCD and ASCII Error detection;
1.Eastron SDM220Modbus Smart Meter Modbus Protocol Implementation V1.0
1.Eastron SDM220Modbus Smart Meter Modbus Protocol Implementation V1.0 1.1 Modbus Protocol Overview This section provides basic information for interfacing the Eastron Smart meter to a Modbus Protocol
Modicon Modbus Protocol Reference Guide. PI MBUS 300 Rev. J
Modicon Modbus Protocol Reference Guide PI MBUS 300 Rev. J 1 Modicon Modbus Protocol Reference Guide PI MBUS 300 Rev. J June 1996 MODICON, Inc., Industrial Automation Systems One High Street North Andover,
Modbus and ION Technology
70072-0104-14 TECHNICAL 06/2009 Modbus and ION Technology Modicon Modbus is a communications protocol widely used in process control industries such as manufacturing. PowerLogic ION meters are compatible
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL w w w. c d v g r o u p. c o m CA-ETHR-A: TCP/IP Module Installation Manual Page Table of Contents Introduction...5 Hardware Components... 6 Technical Specifications...
2. Terminal arrangement. Default (PV display) (SV display) Communication protocol selection Selects the Communication protocol. Modbus ASCII mode:
COMMUNICATION INSTRUCTION MANUAL TEMPERATURE CONTROLLER KT4, KT8 and KT9 No.KTC1E6 2009.05 To prevent accidents arising from the misuse of this controller, please ensure the operator receives this manual.
DS18B20 Programmable Resolution 1-Wire Digital Thermometer
www.dalsemi.com FEATURES Unique 1-Wire interface requires only one port pin for communication Multidrop capability simplifies distributed temperature sensing applications Requires no external components
Quick Installation. A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding. Quick Installation
Quick Installation A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding This chapter intends to get your new FuzzyScan scanner working with your existing system within minutes. General instructions
M68EVB908QL4 Development Board for Motorola MC68HC908QL4
M68EVB908QL4 Development Board for Motorola MC68HC908QL4! Axiom Manufacturing 2813 Industrial Lane Garland, TX 75041 Email: [email protected] Web: http://www.axman.com! CONTENTS CAUTIONARY NOTES...3 TERMINOLOGY...3
Technical Support Bulletin Nr.18 Modbus Tips
Technical Support Bulletin Nr.18 Modbus Tips Contents! Definitions! Implemented commands! Examples of commands or frames! Calculating the logical area! Reading a signed variable! Example of commands supported
2011, The McGraw-Hill Companies, Inc. Chapter 3
Chapter 3 3.1 Decimal System The radix or base of a number system determines the total number of different symbols or digits used by that system. The decimal system has a base of 10 with the digits 0 through
User Manuals. Connection to Siemens S5 PU (AS511) Part Number: 80860.699. Version: 2. Date: 18.10.2006
User Manual Connection to Siemens S5 PU (AS511) Part Number: 80860.699 Version: 2 Date: 18.10.2006 Valid for: User Manuals Version Date Modifications 1 09.06.2006 First Edition 2 18.10.2006 Optimized data
Process Control and Automation using Modbus Protocol
Process Control and Automation using Modbus Protocol Modbus is the fundamental network protocol used in most industrial applications today. It is universal, open and an easy to use protocol. Modbus has
LOCAL INTERCONNECT NETWORK (LIN)
54B-1 GROUP 54B LOCAL INTERCONNECT NETWORK (LIN) CONTENTS GENERAL INFORMATION........ 54B-2............ 54B-3 STRUCTURE................... 54B-2 54B-2 LIN refers to "Local Interconnect Network," which
Single channel data transceiver module WIZ2-434
Single channel data transceiver module WIZ2-434 Available models: WIZ2-434-RS: data input by RS232 (±12V) logic, 9-15V supply WIZ2-434-RSB: same as above, but in a plastic shell. The WIZ2-434-x modules
TSX ETY 110 Module 8
Module 8 Introduction Subject of this chapter What s in this Chapter? This chapter describes the implementation of a TSX ETY 110 module. This chapter contains the following sections: Section Topic Page
Programming Flash Microcontrollers through the Controller Area Network (CAN) Interface
Programming Flash Microcontrollers through the Controller Area Network (CAN) Interface Application te Programming Flash Microcontrollers through the Controller Area Network (CAN) Interface Abstract This
PRODUCT MANUAL SKX OPEN SKX ADVANCE ZN1RX-SKXOPEN. Edition 2 Version 1.1
PRODUCT MANUAL SKX OPEN SKX ADVANCE ZN1RX-SKXOPEN Edition 2 Version 1.1 INDEX 1. Introduction... 3 1.1. SKX Interface... 3 1.2. SKX Installation... 5 1.3. SKX Advance: Application Program... 5 1.3.1. SKX
DS1307ZN. 64 x 8 Serial Real-Time Clock
DS137 64 x 8 Serial Real-Time Clock www.maxim-ic.com FEATURES Real-time clock (RTC) counts seconds, minutes, hours, date of the month, month, day of the week, and year with leap-year compensation valid
APPENDIX A: ERROR CODES
APPENDIX A: ERROR 20001 Unable to load a Remove and replace cassette Check the micro-switch located on the inside left wall of the 20002 Low Cash. Replenish the cash If using less than 75 bills, disable
User Manual. AS-Interface Programmer
AS-Interface Programmer Notice: RESTRICTIONS THE ZMD AS-INTERFACE PROGRAMMER HARDWARE AND ZMD AS-INTERFACE PROGRAMMER SOFTWARE IS DESIGNED FOR IC EVALUATION, LABORATORY SETUP AND MODULE DEVELOPMENT ONLY.
CMC-PD01 PROFIBUS DP Slave Communication Card Operation Manual
CMC-PD01 PROFIBUS DP Slave Communication Card Operation Manual CMC-0205820-01 Table of Content 1 Introduction to CMC-PD01... 2 1.1 Product Introduction... 2 1.2 Features... 2 2 Product Profile and Outline...
OPERATING INSTRUCTIONS Model ST-888 DTMF ANI/ENI Display Decoder
P R O D U C T G R O U P OPERATING INSTRUCTIONS Model ST-888 DTMF ANI/ENI Display Decoder Manual # 600-0901 November 30, 1999 Rev. D - 99068 DESCRIPTION The ST-888 Mobilecall Display Decoder is a desktop
DS2401 Silicon Serial Number
19-5860; Rev 3/15 Silicon Serial Number BENEFITS AND FEATURES Guaranteed Unique 64-Bit ROM ID Chip for Absolute Traceability o Unique, Factory-Lasered and Tested 64-Bit Registration Number (8-Bit Family
DS1821 Programmable Digital Thermostat and Thermometer
ma www.maxim-ic.com FEATURES Requires no external components Unique 1-Wire interface requires only one port pin for communication Operates over a -55 C to +125 C (67 F to +257 F) temperature range Functions
Card Issuing Machine for Magnetic, Contact & IC Card
9100-0020 SPECIFICATION M 1 OF 68 2007. 07. 28. Card Issuing Machine for Magnetic, Contact & IC Card KYTronics Corp.,Ltd 3 rd Floor, A-Dong, Twin Town-Bldg, 703-2. Gojan-Dong, AnSan-City, Kyung Ki-Do,
DS1990A-F5. Serial Number ibutton TM
www.dalsemi.com SPECIAL FEATURES Upgrade of DS1990 allows multiple Serial Number ibuttons to reside on a common bus Unique 48 bit serial number Low-cost electronic key for access control 8-bit CRC for
AN141 SMBUS COMMUNICATION FOR SMALL FORM FACTOR DEVICE FAMILIES. 1. Introduction. 2. Overview of the SMBus Specification. 2.1.
SMBUS COMMUNICATION FOR SMALL FORM FACTOR DEVICE FAMILIES 1. Introduction C8051F3xx and C8051F41x devices are equipped with an SMBus serial I/O peripheral that is compliant with both the System Management
Ethernet. Customer Provided Equipment Configuring the Ethernet port.
Installing the RDSP-3000A-NIST Master Clock. Ethernet Connect the RJ-45 connector to a TCP/IP network. Equipment The following equipment comes with the clock system: RDSP-3000A-NIST Master Clock Module.
Jena er Antriebstechnik. GmbH. 1. Introduction. 2. Properties. 3. Hardware. 4. Baud Rates. Brief Instructions - CANopen Interface
Project : ECOSTEP 100/200 Application Note No. 23 Page 1 of 10 Prepared by: Henrik Bräutigam Operation of ECOSTEP at CANopen Bus Date: 05-01-05 Brief Instructions - CANopen Interface 1. Introduction The
Consult protocol, Nissan Technical egroup, Issue 6
Consult protocol, Nissan Technical egroup, Issue 6 1. Electrical and Signaling protocol 1.1. Consult terminal or PC communications is via three wire bus. TX, RX and Async Clock. 1.2. TX data to ECU level
LTM-1338B. Plus Communications Manual
LTM-1338B Plus Communications Manual 2000. Best Power, Necedah, Wisconsin All rights reserved. Best Power The System Setup option from the Main Menu on the front panel is passwordprotected. The default
W25Q80, W25Q16, W25Q32 8M-BIT, 16M-BIT AND 32M-BIT SERIAL FLASH MEMORY WITH DUAL AND QUAD SPI
8M-BIT, 16M-BIT AND 32M-BIT SERIAL FLASH MEMORY WITH DUAL AND QUAD SPI - 1 - Preliminary - Revision B Table of Contents 1. GENERAL DESCRIPTION... 5 2. FEATURES... 5 3. PIN CONFIGURATION SOIC 208-MIL...
MTS Master Custom Communications Protocol APPLICATION NOTES
MTS Master Custom Communications Protocol APPLICATION NOTES Rev. 0 12/6/94 Contents INTRODUCTION... 1 ACCOL TERMINAL ASSIGNMENTS... 1 MTS PROTOCOL SIGNAL LIST... 2 COMMUNICATIONS INTERFACE... 3 Line Parameter
DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual
DVPPF02-H2 PROFIBUS DP Slave Communication Module Application Manual Warning Please read this instruction carefully before use and follow this instruction to operate the device in order to prevent damages
TAP Interface Specifications
TAP Interface Specifications This Document is for those who want to develop their own paging control software or add an interface for the WaveWare v9 Series Paging Encoder to their existing software applications.
Develop a Dallas 1-Wire Master Using the Z8F1680 Series of MCUs
Develop a Dallas 1-Wire Master Using the Z8F1680 Series of MCUs AN033101-0412 Abstract This describes how to interface the Dallas 1-Wire bus with Zilog s Z8F1680 Series of MCUs as master devices. The Z8F0880,
Application Note. Introduction AN2471/D 3/2003. PC Master Software Communication Protocol Specification
Application Note 3/2003 PC Master Software Communication Protocol Specification By Pavel Kania and Michal Hanak S 3 L Applications Engineerings MCSL Roznov pod Radhostem Introduction The purpose of this
73M1866B/73M1966B FXOCTL Application User Guide November 2, 2009 Rev. 4.1 UG_1x66B_009
Simplifying System Integration TM 73M1866B/73M1966B FXOCTL Application User Guide November 2, 2009 Rev. 4.1 73M1866B/73M1966B FXOCTL Application User Guide 2009 Teridian Semiconductor Corporation. All
L5354 ControlNet Communications Interface
L5354 ControlNet Communications Interface Technical Manual HA470733 Issue 2 Copyright SSD Drives Inc 2005 All rights strictly reserved. No part of this document may be stored in a retrieval system, or
NEC Express5800 Series NEC ESMPRO AlertManager User's Guide
NEC Express5800 Series NEC ESMPRO AlertManager User's Guide 7-2006 ONL-4152aN-COMMON-128-99-0606 PROPRIETARY NOTICE AND LIABILITY DISCLAIMER The information disclosed in this document, including all designs
Road Vehicles - Diagnostic Systems
SSF 14230 Road Vehicles - Diagnostic Systems Keyword Protocol 2000 - Part 1 - Physical Layer Swedish Implementation Standard Document: SSF 14230-1 Status: Issue 3 Date: October 22, 1997 This document is
Getting Started with IntelleView POS Administrator Software
Getting Started with IntelleView POS Administrator Software Administrator s Guide for Software Version 1.2 About this Guide This administrator s guide explains how to start using your IntelleView POS (IntelleView)
CAM-VGA100 User Manual
CAM-VGA100 User Manual Release Note: 1. Jan 28, 2004 official released v1.0 2. Feb 24, 2004 official released v1.1 Fix the definition of verify code Fix the bug of unable jump to power save mode Fix the
Model 5511 Filler Controller User s Manual Version 1.1 October 2011
Thompson Scale Company WEIGHING SYSTEMS & PACKAGING MACHINERY CONTROLS 2758 Bingle Road Houston, Texas 77055 Phone: 713/932-9071 Fax: 713/932-9379 www.thompsonscale.com Model 5511 Filler Controller User
LAUNDRY MACHINES. 143 Rev. B
LAUNDRY MACHINES 8 8.1.1. Overview An important function of the SMS2 software is to manage Smart Card operated laundry machines that are equipped with Greenwald Intellicard Machine Card Readers. The Laundry
GPRS M-Bus Master. User Manual. An Economical and Practical Solution For Remote Automactic M-Bus Smart Meter Reading by GPRS In The Worldwide!
An Economical and Practical Solution For Remote Automactic M-Bus Smart Meter Reading by GPRS In The Worldwide! GPRS M-Bus Master User Manual Mx Series Ver 1.00 Date Issued: 2015-07-28 All rights reserved
Software Manual RS232 Laser Merge Module. Document # SU-256521-09 Rev A
Laser Merge Module Document # SU-256521-09 Rev A The information presented in this document is proprietary to Spectral Applied Research Inc. and cannot be used for any purpose other than that for which
Microcontroller Based Low Cost Portable PC Mouse and Keyboard Tester
Leonardo Journal of Sciences ISSN 1583-0233 Issue 20, January-June 2012 p. 31-36 Microcontroller Based Low Cost Portable PC Mouse and Keyboard Tester Ganesh Sunil NHIVEKAR *, and Ravidra Ramchandra MUDHOLKAR
Brunata Optuna W (171)
Brunata Optuna W (171) Communication description Edition 1.1 UK-QB101414 / 26.02.2013 Brunata a/s is a Danish owned company. We have more than 90 years of experience within developing and producing meters,
Serial Communications Protocol. Data 2179 Revision 4. For Use With Cooper Power Systems Apparatus Controls: Form 6 Recloser Control
Controls Serial Communications Protocol Reference Information R28-9-2 Serial Communications Protocol Data 279 Revision 4 For Use With Cooper Power Systems Apparatus Controls: Form 6 Recloser Control Form
LENORD. +BAUER... automates motion. Fieldbus connection absolute encoders CANopen. Reference. Communication profile DS-301 Device profile DS-406
Fieldbus connection absolute encoders CANopen Communication profile DS-30 Device profile DS-406 LENORD +BAUER... automates motion. Reference D-0R-xCO (.) Right to technical changes and errors reserved.
LIN (Local Interconnect Network):
LIN (Local Interconnect Network): History: LIN (Local Interconnect Network) was developed as cost-effective alternate to CAN protocol. In 1998 a group of companies including Volvo, Motorola, Audi, BMW,
K-line Communication Description
K-line Communication Description Introduction There are two primary ISO documents that describe how to perform OBD communications on K- line between a tester and a vehicle. There are actually several ISO
AN601 I2C 2.8 Communication Protocol. SM130 SM130 - Mini APPLICATION NOTE
AN601 I2C 2.8 Communication Protocol SM130 SM130 - Mini APPLICATION NOTE 2 1. INTRODUCTION This application note explains I2C communication protocol with SM130 or SM130-Mini Mifare module based on the
MCB3101 (Class I) WiRobot Serial Bluetooth Wireless Module User Manual
MCB3101 (Class I) WiRobot Serial Bluetooth Wireless Module User Manual Version: 1.0.1 Dec. 2005 Table of Contents I. Introduction 2 II. Operations 2 II.1. Theory of Operation 2 II.2. Configuration (PC-PC
D-MAX WEB GUIDE CONTROLLER WITH OPERATOR INTERFACE PANEL QUICK START SETUP MANUAL
1/1 D-MAX.D1 1A Manual S1 D-MAX OPERATOR INTERFACE (Application Home Screen Is Shown) D-MAX CONTROLLER 04/14/2008 2008 Fife Corporation. All rights reserved. Figure Sheet 2-249 This page is intentionally
Kurz Instruments Inc. Document 360209-AV Document Title: MFTB Event Code Definitions. MFT B-Series Event Codes
MFT B-Series Event Codes The MFT B-series status information is contained in a 4-byte long word (32-bit) Event Code. This Event Code provides a bit-wise mapping of the status of the flow meter with each
Comdial Network Management System User Instructions
Comdial Network Management System User Instructions GCA40 237.01 8/00 printed in U.S.A. Microsoft and Windows 95 are registered trademarks of Microsoft Corporation, Redmond WA. pcanywhere is a registered
7 OUT1 8 OUT2 9 OUT3 10 OUT4 11 OUT5 12 OUT6 13 OUT7 14 OUT8 15 OUT9 16 OUT10 17 OUT11 18 OUT12 19 OUT13 20 OUT14 21 OUT15 22 OUT16 OUT17 23 OUT18
18 CHANNELS LED DRIVER GENERAL DESCRIPTION IS31FL3218 is comprised of 18 constant current channels each with independent PWM control, designed for driving LEDs. The output current of each channel can be
Aquadyne TechTip TITLE: TROUBLESHOOTING PC COM PORT AND MODEM PRODUCTS AFFECTED SYMPTOMS POSSIBLE CAUSES
Aquadyne TechTip TITLE: TROUBLESHOOTING PC COM PORT AND MODEM COMMUNICATIONS WITH AN OCTOPUS. Article # 072297-1 Last reviewed: 03/25/98 Keywords: Serial Port, Modem, Polling, AquaWeb, Node Not Responding
LOCAL INTERCONNECT NETWORK (LIN)
54C-1 GROUP 54C LOCAL INTERCONNECT NETWORK (LIN) CONTENTS GENERAL INFORMATION...54C-2 SPECIAL TOOL...54C-3...54C-4 DIAGNOSTIC FUNCTION...54C-4 DIAGNOSTIC TROUBLE CODE CHART...54C-6 DIAGNOSTIC TROUBLE CODE
Allows the user to protect against inadvertent write operations. Device select and address bytes are Acknowledged Data Bytes are not Acknowledged
Write Protect CAT24WCxxx I 2 C Serial EEPROMs. Allows the user to protect against inadvertent write operations. WP = V CC : Write Protected Device select and address bytes are Acknowledged Data Bytes are
udrive-usd-g1 Embedded DOS micro-drive Module Data Sheet
4D SYSTEMS udrie-usd-g1 Embedded DOS micro-drive Module Document Date: 2nd April 2009 Document Revision: 2.0 Page 1 of 9 udrie-usd-g1 Embedded DOS micro-drive 4D SYSTEMS Description Features The is an
8-Bit Flash Microcontroller for Smart Cards. AT89SCXXXXA Summary. Features. Description. Complete datasheet available under NDA
Features Compatible with MCS-51 products On-chip Flash Program Memory Endurance: 1,000 Write/Erase Cycles On-chip EEPROM Data Memory Endurance: 100,000 Write/Erase Cycles 512 x 8-bit RAM ISO 7816 I/O Port
LEN s.r.l. Via S. Andrea di Rovereto 33 c.s. 16043 CHIAVARI (GE) Tel. +39 0185 318444 - Fax +39 0185 472835 mailto: [email protected] url: http//www.len.
MA511 General Index 1 INTRODUCTION... 3 1.1 HARDWARE FEATURES:... 4 2 INTERFACE... 5 2.1 KEYBOARD... 6 2.2 POWER ON... 7 2.3 POWER OFF... 7 2.4 DETECTOR CONNECTION... 7 2.5 DETECTOR SUBSTITUTION...7 3
PCAN-MicroMod Universal I/O Module with CAN Interface. User Manual. Document version 2.1.0 (2014-01-16)
PCAN-MicroMod Universal I/O Module with CAN Interface User Manual Document version 2.1.0 (2014-01-16) Products taken into account Product Name Part number Model PCAN-MicroMod IPEH-002080 with firmware
SenseLink TM. End-Point Controller. Addendum
SenseLink TM End-Point Controller Addendum MKS Instruments, Inc. Control & Information Technology Products Group 3350 Scott Blvd Bldg 4 Santa Clara, CA 95054 Main: 408.235.7620 Fax: 408.235.7625 SenseLink
Sierra Dual 24 Volt Brushless DC Motor Controller Product Specification
Sierra Dual 24 Volt Brushless DC Motor Controller Product Specification Assembly 025A0215 600A0942 Rev. A May 14, 2012 025A0215 Brushless DC Motor Controller Page 1 Revision History ECN # Date Rev Description
A+ Guide to Managing and Maintaining Your PC, 7e. Chapter 1 Introducing Hardware
A+ Guide to Managing and Maintaining Your PC, 7e Chapter 1 Introducing Hardware Objectives Learn that a computer requires both hardware and software to work Learn about the many different hardware components
x10* CP290 HOME CONTROL INTERFACE PROGRAMMING GUIDE FOR ADVANCED PROGRAMMERS
x10* CP290 HOME CONTROL INTERFACE PROGRAMMING GUIDE FOR ADVANCED PROGRAMMERS 1 TABLE OF CONTENTS 3. Introduction. 6. Programming. 7. RS-232 connections. a. Byte format. 9. Download Base Housecode. IO.
