Zenith Series MDU & RDU. Critical Power Distribution Units

Size: px
Start display at page:

Download "Zenith Series MDU & RDU. Critical Power Distribution Units"

Transcription

1 Zenith Series MDU & RDU Critical Power Distribution Units

2 Touching all Areas of the Energy Industry GE s diverse portfolio of products and services is helping customers solve problems every day. We touch all areas of the energy industry including energy, electrical management, smart grid modernization, coal, oil, gas, nuclear energy, water, wind, solar and biogas. Providing Reliable Power to your Mission-Critical Business Needs With a comprehensive energy management portfolio, GE is uniquely qualified to provide comprehensive datacenter, commercial and industrial infrastructure solutions from its Industrial Solutions and Critical Power businesses. Due to the inherent high-efficiencies offered with GE electrical distribution equipment and GE UPS systems, measurement of PUE can be maximized by the integrated use of these solutions. Numerous critical power products and services can be utilized to deliver reliable datacenter infrastructure support, solid project management and outstanding site service solutions. Over 15,000 downloadable resources for our customers GEIndustrial.com/CriticalPower provides customers with access to the latest product and solutions news, downloadable resources and interactive digital tools. Access to the entire portfolio of product solutions: - Brochures - Manuals - White Papers - Software - Drawings - Videos Multi-language support in Chinese and Spanish Industry solution offerings & advanced navigation 2

3 End-to-End GE Solutions for Datacenter Power Needs GE Utility Service Transformer Standby Generator Standby Generator GE MV Main Switchgear GE Generator Paralleling Switchboard GE LV Main Switchgear GE ATS GE LV Switchboard GE Surge Protection GE UPS System GE Critical Power Distribution Products Using Efficient and Flexible Power Distribution to the Critical Load GE Monitored Distribution Unit GE Remote Distribution Unit GE Remote Distribution Unit GE Monitored Distribution Unit Critical Power via Raised Floor Critical Power via Overhead IT Critical Load Servers GE Distributed Power Busway 3

4 Series MDU Monitored Distribution Unit Model MDU-CL (Classic Design) Protect Your Computers GE s Monitored Distribution Unit protects your critical computer equipment from electrical noise and spikes, plus acts as a single point reference ground. Each unit can be individually configured to meet your needs for isolation, voltage transformation, harmonic reduction and voltage regulation with virtually limitless distribution options. Built-in system monitoring and diagnostics facilitate load balancing and warn of potential threats to your critical equipment. Every MDU goes through some of the toughest testing in the industry. GE s comprehensive quality assurance program, with 100% unit inspection and testing, is just one way GE assures that each unit will perform flawlessly day after day. Win the Race for Space We designed our MDU to grow with your facility. Sidecars can be added to the standard cabinet to give you up to six 42-circuit panels or combinations of panels and sub-feed breakers. Up to 252 separate circuits can be installed in a single unit. These circuits can be monitored by one of GE s Branch Circuit Monitoring Systems (BCMS) as a factory installed component. Branch Circuit Monitoring For complete critical load management, add a Branch Circuit Monitoring System (BCMS) to the MDU panelboards. This monitoring provides the user with branch circuit knowledge of current readings average, min/max and alarm settings all displayed in the Intelligent Monitor. Top or Bottom Cabling Use the MDU with bottom cable entry and exit when installing an MDU on a computer room raised access floor. Or use the MDU with top cable entry and exit when installing on a concrete floor and using overhead busway systems. Modular Design GE s modular design results in higher quality due to the standardized pre-testing of all modules, which allows GE to meet the tight project deadlines that datacenters demand. Service and Support After your equipment has been installed, call on the GE service team for 24/7 support. Our experienced sales and service team will stay with you from the design of your system through the life of your datacenter. Single Line Diagram - Model MDU-CL Output GE Panelboards and/or Sub-feed Circuit Breakers* This Classic Design MDU is typically installed on the datacenter computer room floor. * Standard unit contains two 42 circuit GE panelboards. Additional panelboards can be added via use of side cabinets. 4

5 Series MDU Monitored Distribution Unit Model MDU-CL (Classic Design) Features & Options Monitoring Standard Monitor: Intelligent Monitor (for input and output monitoring) Options: BMCS Communications: Serial RS-485 Modbus; optional SNMP communications M4 monitor available Thermal: Dual transformer thermal switches Transient Suppression Network (TSN) (Optional) An integrated system engineered to meet ANSI/ IEEE category C standards for transient voltages and surge currents. Lightning Arrestor/Surge Suppressor (Optional) Protects the insulation of the system magnetics. Distribution Panelboards/ Sub-Feed Breakers (Optional) Customized distribution configurations meet the demands of any facility. Front-facing or side-facing side cars for CB distribution in excess of 84 poles. Step-Down Transformers TP-1, K20 high-efficiency transformers are standard Copper wound with Class R insulation Low-inrush versions available Ratings kva Ratings: kva Input: 3-phase, 3 wire plus ground Input Voltage: 600, 575, 480, 208 (60 Hz) 575, 415/240, 380/220 (50 Hz) Output: 3-phase, 4 wire plus ground Output Voltage: 600, 575, 484, 208 (60 Hz) 575, 415/240, 380/220 (50 Hz) Enclosure NEMA 1 enclosure with removable front side & rear panels Optional NEMA 3R enclosure Removable front, side and rear panels Integrated two-point latch and vision panels Flush-mounted door handle with integral locks Advanced door catch assures positive closure Operating Conditions Operating Temperature: ambient 0 C to +40 C Storage Temperature: ambient -10 C to +40 C 50 Hz Operating Range: Hz 60 Hz Operating Range: Hz Features GE panelboards and circuit breakers Copper wound construction better conducting and more resilient than aluminum Dual electrostatic shield attenuates high frequency noise Oversized neutral conductor Common mode noise protection Transverse mode noise protection Accurate kw, power factor and THD measurement True RMS metering Operating Efficiency: 98% typical Listed to UL 1950, CSA Certified Modbus RTU communications BCMS available as factory installed option Door-in-Door Construction Model MDU-CL MDU-CL Dimensions kva Height Width Depth Side-facing side car adds 9 width Front-facing side car adds 21 width Consult factory for system weights 5

6 Branch Circuit Monitoring System A Optionally Available for Series MDU & RDU Products GE s Branch Circuit Monitoring System (BCMS) measures and displays the current and/or voltage of each individual power panelboard circuit. BCMS settings can be custom configured within a customer s power management system to create alarms for current and/or voltage thresholds. BCMS Basic or BCMS Plus is available, depending on the level of monitoring desired. B A BCMS Data Acquisition Board B FEATURE BCMS BASIC BCMS PLUS Intelligent Monitor Display (optional) Monitoring Modbus RTU SNMP (optional) Individual Current Per Branch Circuit Average Current Minimum/Maximum Current Alarm Setting and Summary Alarm via ModBus Summation of Branch Circuits Per Panelboard Current Demand kva, kw, Power Factor and Frequency Reactive Power (kvar) Over/Under Voltage Phase, Neutral and Ground Input Current Panel Phase Loss Voltage: L-L, L-N Zero Current Alarm Voltage THD Energy Consumption (kwhr) Percent Load B BCMS Branch Circuit 21-Pole C/T Strip Intelligent Monitor Can Display BCMS Readings Standard on Series MDU Optional on Series RDU Intelligent Monitoring gives real-time control of actual loads down to the individual breaker level. This important decision-making tool integrates the BCMS and Intelligent Monitoring System for control of system-wide performance and breaker power levels along with current and voltage data. This means improved, more timely decisions can be made based on real-time load and capacity data, all in one interactive and monitoring package. 6

7 Series MDU Monitored Distribution Unit Model MDU-HP (High Power Design) The Series MDU High-Power Design provides the highest available power density. This system integrates the Intelligent Monitoring with the Branch Circuit Monitoring System and allows precise load control and management. Together these features result in: Less Floor Space Lower Energy Costs Higher Density Power Better Reliability Space Savings The Series MDU-HP uses a high-power, high-efficiency transformer in place of the many smaller, lower-power transformers found on legacy PDUs. Use of the Series MDU-HP often results in a space savings of 20-50%. Lower Energy Costs Market-leading, ultra-high efficiency, eco-friendly transformer yields significant energy savings, substantially lowering datacenter operating costs. Scalability The Series MDU-HP is the smart way to add scalability to your critical environment. The internal distribution system allows the datacenter manager to easily add distribution as servers are added to the site, resulting in a better return on investment. Intelligent Monitoring Intelligent Monitoring increases the visibility of the actual loads on the raised floor, which gives datacenter managers better decision making tools at their fingertips. The monitor provides the ability to make better decisions based upon real-time reporting of load/capacity data. Customized Solutions for Your Operation Versatile product, coupled with advanced engineering expertise, delivers the best performing platform for your critical application. Features Central welded bus on the input and the output allows true front access and simplifies ongoing maintenance Ultra-high efficiency datacenter grade transformer for energy cost savings Reduces power distribution footprint by up to 50% Highest available power density Available per circuit output monitoring option optimizes current utilization Optional 100% rated circuit electronic trip breakers for precision control Customizable to meet specific requirements UL listed Model MDU-HP Step Down Transformer Energy Saving Transformer Technology Designed to optimize efficiency at specified load level (efficiencies as high as 99% at 500 kva). Optimized for non-linear/computer loads. Designed to minimize stray losses (component of magnetic losses that increases dramatically with non-linear profile of the load). Result can be upwards of 1-3% higher efficiency than standard transformers. Results in less heat rejection. Less cooling required results in lower energy costs. 7

8 Series MDU Monitored Distribution Unit Model MDU-HP (High Power Design) Features & Options Electrical Specifications Transformer kva: 225, 300, 400, 500, 625, 750 kva Input Voltage: 480 VAC, 600 VAC 3-phase, 3 wire plus ground, 60Hz Output Voltage: VAC (240 VAC available) 3-phase, 4 wire plus ground, 60Hz Output GE Circuit Breakers: 225 AF / AT (x 14 max.) 400 AF / 400 AT (x 8 max.) 600 AF / AT (x 8 max.) Neutral Bus: 200% rated Transformer Type: Datacenter Grade; Delta-Wye isolation Transformer Specification: K-rated; 150 C rise; copper wound (AI windings available); NEMA TP-1 efficiency Input Current 480 VAC): 150 kva (181); 225 kva (217); 300 kva (361); 400 kva (481); 500 kva (602); 625 kva (753); 750 kva (903) Environmental Specifications Operating Temp: 0 C to 40 C up to 10,000 feet without de-rating Physical Specifications Input/Output Bussing: Configurable for top or bottom Access: Front only (some systems may require side or rear access depending on final installation) System Weight 225 kva = 2100 lbs 500 kva = 3900 lbs 300 kva = 2490 lbs 625 kva = 3900 lbs 400 kva = 2900 lbs 750 kva = 4690 lbs Monitoring Standard Monitor: Intelligent monitor (input and output monitoring) Options: Per circuit output monitoring Communications: Serial RS-485 Modbus; Optional SNMP communications Thermal: Dual transformer thermal switches Options SPD (Surge Protective Device) Dual input with interlocks Low inrush transformer 100% rated circuit breakers Optional monitor IR transparent scan windows Shunt trip per output circuit breaker Integrated BCMS Monitoring for current and voltage Cabinet Dimensions kva Height Width Depth 225/ / / Single Line Diagram - Model MDU-HP GE Sub-feed CBs - 225, 400 or 600A This high-power MDU is typically installed in the building electric room. Monitoring provided for: Input CB All output CBs Alerts the operator if sum of branch currents nears rating of input main CB 8

9 Series RDU Remote Distribution Units Win the Race for Space & Power The drive for more power in less space at the server level continues. GE s Series RDU complements this change by offering the most options available in this free-standing 2 x 2 distribution or server-sized enclosure. GE has the most comprehensive line up of RDU in the datacenter business. Although your RDU may still be able to handle the power demands of your growing facility, it may not have room for expansion. GE s RDU helps you win the race for space & power by providing the added pole space in a variety of power set-ups to meet your distribution needs in a small footprint. Our RDU allows you to effectively use all of your existing capacity before investing in additional distribution. The RDU can use multiple input sources, up to 168 breakers, and Branch Circuit Monitoring with local monitoring in the 2 x 2 floor tile. The RDU is fed by any standard sub-feed circuit breaker of an MPU or 208V distribution board. GE also offers the choice of Mission-Critical Dual Source RDU. Flexible Packaging Designed in an aesthetically pleasing cabinet to match the high-tech look of today s computer centers, the RDU s flexible configuration options allow it to grow with your facility. The RDU can function as a stand alone device or as part of an extensive distribution system. You can choose a single input device or dual power feeds to satisfy system redundancy and maintenance requirements. All RDU designs can be packaged to allow for system expansion without interruption to your loads. Each unit can be equipped with any custom monitoring package you require for your system. Simplified Expansion with Customized Options Reduces the length of cable runs between your RDU and the individual loads Optimizes usable floor space Simplifies server consolidation plans Meets the growth demands of dual cord equipment Retrofits to any existing distribution system Minimizes your investment risk today by allowing for incremental expansion of your future facility Unobstructed wiring access for ease of Installation RDU Intelligent Monitoring Add an optional Intelligent Monitor to see down to the branch circuit level on all panelboards. The monitor increases the visibility of the actual loads on the raised floor, which gives the datacenter manager a better decision-making tool that covers system-wide performance, individual output breakers power levels and branch circuit monitoring (current and voltage). The Intelligent Monitor gives you the ability to make better decisions based upon real time reporting of load/capacity data. By adding the monitor to your RDU, you can view linked devices and keep better control of the datacenter floor loads. 9

10 RDU-CL Classic Design Series RDU Remote Distribution Units RDU-MC Mission Critical Design Breaker Interlocks Model RDU CL (Classic Design) 2 x 2 footprint cabinet (83 high) Freestanding enclosure Removable top, side and rear panels Full front inner hinged panelboard cover 208/120 VAC - 60 Hz or 50 Hz available 1, 2 or 4 mains, 225 or 400A rated GE Mains can be CB or MCS type 400A system also available GE 42 pole distribution panelboards Panelboard vision panels Listed to UL standards Oversized neutral for non-linear loads Single-point grounding Configurable for top or bottom entry Compression connections on all GE panelboards Hinged side and rear panels Flush-mounted door handle with integral keyed locks Increased wiring space Door-in-door handle on dead front Model RDU-MC (Mission Critical Design) 2 x 2 footprint cabinet (83 high) Enhanced security Designed to provide an alternate feed to loads MLO (main lugs only) GE panelboards 225 or 400A Two 225A GE mission critical Main CBs Kirk key interlocks Solenoid key release Sync check relay Can be switched between two sources in a make-before-break configuration without interrupting the load Isolated and equipment grounds Switching neutral contactor for separately derived loads Centralized MDU with RDU Remote Distribution Advantages Condenses overall power distribution system footprint Uses a high-efficiency transformer Extra CBs simplifies future expansion using RDUs Welded bus design simplifies ongoing maintenance and provides front access design Available as manual dual unit for A side / B side bus designs Often more cost effective than distributed transformers Branch Circuit Monitoring System (BCMS) Available on all RDU designs Optional Intelligent Monitor display Retrofit BCMS kits available for existing PDUs or panelboards 10

11 Series RDU Remote Distribution Units RDU-SC Server Cabinet Design Model RDU-SC (Server Cabinet Design) 24 w x 82 h (24 or 42 dp) Front only or front and rear in-line dual 42 pole GE panelboards with bolt-on circuit breakers Single or dual feed via easy to access copper bus bar inputs 225A GE Main CB per panelboard or per two panelboards 400A system also available Hinged dead front doors with ¼ turn captive hardware and quick removal clip Lockable main door with easy view of all circuits (acrylic or solid finish) Branch circuit monitoring available Large system status display Top or bottom entry, ultra spacious conduit access area with ¼ turn captive hardware Easy-access solid copper 200% rated bus bar neutral terminal block Standard ground bus and optional isolated ground bus Solid copper input bus bars Monitoring package including BMCS in single monitor available Model RDU WM (Wall Mount Design) Wall mount design One or two GE Panelboards; One or two GE Main CBs 225 or 400A GE Mains (CB or MCS) 9 dp x 26 w x 80.5 h Space saver version (No BMCS allowed) 9.5 dp x 26 w x 66.5 h Full front inner hinged panelboard cover 208/120 VAC - 60 Hz or 50 Hz available Panelboard vision panels Listed to UL standards Oversized neutral for non-linear loads Single-point grounding Configurable for top or bottom entry Compression connections on all GE panelboards Flush-mounted door handle with integral keyed locks Increased wiring space Door-in-door handle on dead front Series MDU Monitored Distribution Unit Series RDU Remote Distribution Units Series DPB Distributed Power Busway Sub-feed breakers in MDU can distribute power to RDUs or DPB Busway end tap boxes 11

12 2013 General Electric Company. GE, the GE Monogram, imagination at work, Zenith and all other trademarks, registered trademarks and service marks, unless otherwise noted, are owned or licensed by the General Electric Company or its subsidiaries. The contents of this document are the property of General Electric Company. No part of this work may be reproduced or transmitted in any form or by any means, except as permitted in written license agreement with General Electric Company. The information contained in this document is subject to change without notice. Customer Service Support Toll-Free: US-Based Customer Service Answered Live 24/7 GEIndustrial.com/CriticalPower dea-569, Rev. 2/13

APC 3Phase Power Distribution

APC 3Phase Power Distribution APC 3Phase Power Distribution North American 3 Phase Business Development Team All content in this presentation is protected 2008 American Power Conversion Corporation Objectives Understand the entire

More information

Doc Ref: 2015.06.01.002. 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

Doc Ref: 2015.06.01.002. 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC TM 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC TM D400E Data Module (60Hz) The EDGE D400E is designed to meet high power density requirements for both the HPC and Web Scale environments while

More information

LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification

LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification 08/17/12 Rev2 LTR Series General Specification 700 VA to 2.1 KVA 1.0 General LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA General Specification This specification describes the features and

More information

Power Management Module 2. Installation

Power Management Module 2. Installation Power Management Module 2 30 300 kva Installation Table of Contents Safety... 1 Safety Instructions... 1 Certification Standards Three Phase... 1 Product Safety... 2 Special Precautions... 2 System Description...

More information

Liebert PPC Second Generation Power Distribution Cabinet

Liebert PPC Second Generation Power Distribution Cabinet Liebert PPC Second Generation Power Distribution Cabinet Emerson Network Power Delivers The Packaged Power Solution Creating high quality power is a major step towards protecting the operation of a critical

More information

QuickSpecs. Overview. HP Power Distribution Rack. HP Power Distribution Rack. DA - 12859 North America Version 5 August 22, 2008 Page 1

QuickSpecs. Overview. HP Power Distribution Rack. HP Power Distribution Rack. DA - 12859 North America Version 5 August 22, 2008 Page 1 Overview It's getting harder to manage a data center efficiently, with rising utility bills and ever-increasing demands due to processor power and server density increases. Growing user requests mean heavier

More information

S c h n e i d e r E l e c t r i c BUSINESS IMPACT. Jack Hack Enterprise System Engineer 19 November 2015

S c h n e i d e r E l e c t r i c BUSINESS IMPACT. Jack Hack Enterprise System Engineer 19 November 2015 S c h n e i d e r E l e c t r i c BUSINESS IMPACT Datacenter means business - create the bridge between IT en Facilities. Jack Hack Enterprise System Engineer 19 November 2015 1 Your ability to compete

More information

Product catalog. Cyberex data center products Overview catalog

Product catalog. Cyberex data center products Overview catalog Product catalog Cyberex data center products Overview catalog 2 Product catalog Cyberex data center products overview World class leader in mission critical power quality products and services About us

More information

Circuit Breakers and Switchgear. Thomas Greer Director of Engineering TLG Services

Circuit Breakers and Switchgear. Thomas Greer Director of Engineering TLG Services Circuit Breakers and Switchgear Thomas Greer Director of Engineering TLG Services Presentation Outline Switchgear Definition Overcurrent Protection Devices Circuit Breaker Trip Curves and Coordination

More information

Eaton 93PM UPS Where aesthetics meet intelligence.

Eaton 93PM UPS Where aesthetics meet intelligence. Brochure 100 kw Eaton 93PM UPS Where aesthetics meet intelligence. 93PM features and benefits The Eaton 93PM UPS combines unprecedented and reliability with eye-catching design. A space-saving, flexible

More information

Engineers Edge, LLC PDH & Professional Training

Engineers Edge, LLC PDH & Professional Training 510 N. Crosslane Rd. Monroe, Georgia 30656 (770) 266-6915 fax (678) 643-1758 Engineers Edge, LLC PDH & Professional Training Copyright, All Rights Reserved Engineers Edge, LLC An Introduction to Interior

More information

Galaxy VM. Three-phase power protection. schneider-electric.com

Galaxy VM. Three-phase power protection. schneider-electric.com Galaxy VM Three-phase power protection schneider-electric.com 2 schneider-electric.com schneider-electric.com 3 Galaxy VM trusted partner for your business continuity Features and benefits Highly efficient,

More information

TLE Series UPS 225-1500 kw for best-in-class multi-mode operating efficiency

TLE Series UPS 225-1500 kw for best-in-class multi-mode operating efficiency TLE Series UPS 225-1500 kw for best-in-class multi-mode operating efficiency Ensuring Uptime for Critical Processes Mission-critical processes need a power system that is cleaner and more reliable than

More information

415V DISTRIBUTION FOR GREEN DATA CENTERS

415V DISTRIBUTION FOR GREEN DATA CENTERS White Paper: HMRP-WP001-A5 June 5, 2012 415V DISTRIBUTION FOR GREEN DATA CENTERS Prepared by: Anthony (Tony) Hoevenaars, P. Eng President and CEO Mirus International Inc. Copyright 2012 Mirus International

More information

SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions

SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS POWER DISTRIBUTION RACKS IN A MISSION CRITICAL SYSTEM MODULES IN A MISSION CRITICAL SYSTEM UPS Convertor Main Inverter Load Battery BPC UPS & BATTERY

More information

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Submit shop drawings for equipment provided under this section Shop drawings shall indicate: Section 16435 - SWITCHBOARDS Introduction Part 1 - General Reference The work under this section is subject to requirements of the Contract Documents including the General Conditions, Supplementary Conditions,

More information

PX100 MBP with Configurable Distribution

PX100 MBP with Configurable Distribution PX100 MBP with Configurable Distribution High-performance, right-sized, 3-phase power protection with industry-leading efficiency, availability, and performance for small and medium data centers July 2012

More information

GE Digital Energy. TLE Series UPS. 160-400 kw three phase 400 Vac. with best-in-class efficiency. gimagination at work

GE Digital Energy. TLE Series UPS. 160-400 kw three phase 400 Vac. with best-in-class efficiency. gimagination at work GE Digital Energy TLE Series UPS 160-400 kw three phase 400 Vac with best-in-class efficiency gimagination at work GE provides clean, efficient and reliable power for today s digital world with the ultra

More information

TLE Series UPS 160-800 kva/kw three phase 400 Vac with best-in-class efficiency

TLE Series UPS 160-800 kva/kw three phase 400 Vac with best-in-class efficiency GE Critical Power TLE Series UPS 160-800 kva/kw three phase 400 Vac with best-in-class efficiency imagination at work GE provides clean, efficient and reliable power for today s digital world with the

More information

SWITCHGEAR. EGP Switchgear

SWITCHGEAR. EGP Switchgear SWITCHEA EP Switchgear Cat generator set paralleling switchgear has been designed to integrate with Cat EMCP3 generator set controls. Now you can get greater efficiency, reliability and dependability all

More information

Distributing Power to Blade Servers

Distributing Power to Blade Servers Distributing Power to Blade Servers Ten steps to selecting the optimal power distribution design With the growth in blade servers with dual or triple power supplies, a single rack of equipment can easily

More information

SG Series UPS 10-150 kva. high efficiency systems

SG Series UPS 10-150 kva. high efficiency systems SG Series UPS 10-150 kva high efficiency systems Touching all Areas of the Energy Industry With more than 100,000 employees in over 100 countries, GE s diverse portfolio of products and services is helping

More information

Secondary Unit Substations

Secondary Unit Substations 14 SWITCHGEAR Secondary Unit Substations Overview Siemens offers a wide variety of unit substation designs to meet customer requirements. A unit substation consists of one or more transformers mechanically

More information

Power Meter Series 700

Power Meter Series 700 PowerLogic power-monitoring units Power Meter Series 700 Technical data sheet 2007 Functions and characteristics E90463 The PowerLogic Power Meter Series 700 offers all the measurement capabilities required

More information

Considerations for a Highly Available Intelligent Rack Power Distribution Unit. A White Paper on Availability

Considerations for a Highly Available Intelligent Rack Power Distribution Unit. A White Paper on Availability Considerations for a Highly Available Intelligent Rack Power Distribution Unit A White Paper on Availability Introduction Data centers are currently undergoing a period of great change. Data center managers

More information

415V DISTRIBUTION FOR GREEN DATA CENTERS

415V DISTRIBUTION FOR GREEN DATA CENTERS White Paper: HMRP-WP001-A1 October 1, 2010 415V DISTRIBUTION FOR GREEN DATA CENTERS Prepared by: Anthony (Tony) Hoevenaars, P. Eng President and CEO Mirus International Inc. Copyright 2005 Mirus International

More information

Next Generation Power Distribution for the High-Density Datacenter

Next Generation Power Distribution for the High-Density Datacenter Next Generation Power Distribution for the High-Density Datacenter George Wasielewski Eaton/Powerware Power Quality Products and Services Dallas Enhance (IT) July 10, 2008 2007 Eaton Corporation. All rights

More information

Proper Application of 415V Systems in North American Data Centers. A White Paper from the Experts in Business-Critical Continuity

Proper Application of 415V Systems in North American Data Centers. A White Paper from the Experts in Business-Critical Continuity Proper Application of 415V Systems in North American Data Centers A White Paper from the Experts in Business-Critical Continuity Introduction Increasing pressure to reduce operating expenses and be more

More information

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80 Buck-Boost Transformers Single and Three Phase Potted Buck-Boost Transformers Buck-Boost Applications & Standard Specification... 80 Selecting Buck-Boost Transformers... 81 Single Phase Selection Tables...

More information

PMCS. Integrated Energy Management Solution. Unlock the Full Potential of Power Networks Through Integration. Complete Solution. Informed Decisions

PMCS. Integrated Energy Management Solution. Unlock the Full Potential of Power Networks Through Integration. Complete Solution. Informed Decisions PMCS Integrated Energy Management Solution Unlock the Full Potential of Power Networks Through Integration Power Management Control System (PMCS) is a highly customizable, fully integrated end-to-end Energy

More information

Power Distribution Considerations for Data Center Racks

Power Distribution Considerations for Data Center Racks Power Distribution Considerations for Data Center Racks Power Distribution Considerations for Data Center Racks Table of Contents 3 Overview 4 At what voltage do you run all the IT equipment? 4 What electrical

More information

High-Efficiency AC Power Distribution for Data Centers

High-Efficiency AC Power Distribution for Data Centers High-Efficiency AC Power Distribution for Data Centers White Paper 128 Revision 2 by Neil Rasmussen > Executive summary The use of 240 volt power distribution for data centers saves floor space, simplifies

More information

UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES

UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES UNINTERRUPTIBLE POWER SUPPLIES 9900A >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES 9900A The 9900A UPS system uses the most advanced IGBT in both the converter and inverter with Digital Signal Processor (DSP)

More information

TOSHIBA G9000 80/100/160/225 kva

TOSHIBA G9000 80/100/160/225 kva CORPORATE OFFICE 13131 WEST LITTLE YORK ROAD HOUSTON, TX 77041 PHONE: (713) 466-0277 (800) 231-1412 FACSIMILE: (713) 896-5226 TOSHIBA G9000 80/100/160/225 kva GUIDE SPECIFICATION THREE PHASE UNINTERRUPTIBLE

More information

Uninterruptible Power Supply

Uninterruptible Power Supply 96-01101 / rev. 2e / 2-2-12 Uninterruptible Power Supply EXCEPTIONAL SUPPORT & PROTECTION Uninterruptible Power Supply with Energy Saver design that is optimized to address the needs of A/V systems Features

More information

Eaton 93PM UPS Efficient. Scalable. Innovative.

Eaton 93PM UPS Efficient. Scalable. Innovative. Product rochure 20-100 kw aton UPS fficient. Scalable. Innovative. features and benefits The aton UPS combines unprecedented and reliability with an eye-catching design. space-saving, scalable and flexible

More information

SECTION 16002C CAMPUS CENTRAL METERING SYSTEM DESIGN CRITERIA 1. General

SECTION 16002C CAMPUS CENTRAL METERING SYSTEM DESIGN CRITERIA 1. General SECTION 16002C CAMPUS CENTRAL METERING SYSTEM DESIGN CRITERIA 1. General A. Electrical usage on the Brown campus is presently monitored by a Siemens-brand, web-based central metering system, which includes

More information

Increasing Data Center Efficiency by Using Improved High Density Power Distribution

Increasing Data Center Efficiency by Using Improved High Density Power Distribution Increasing Data Center Efficiency by Using Improved High Density Power Distribution By Neil Rasmussen White Paper #128 Executive Summary A new approach to power distribution for high density server installations

More information

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET Berthold Electric Company s Generator Connection Cabinet provides a quick and convenient station to connect a portable generator to a facility s main service

More information

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE for solar energy management LEATEC Delivering Solutions for Energy Management SOLAR ENERGY DATA CENTER BUILDING 4 to8 String Monitoring with 0.% Accuracy

More information

Intelligent Power Distribution in the Data Center

Intelligent Power Distribution in the Data Center Rack Power Intelligent Power Distribution in the Data Center Agenda Data Centre Power UPS Power Distribution Rack Mount PDU s UPS Power problems Configuration Capacity Power Distribution Types of Distribution

More information

City of Leesburg, Florida I.T. Data Center 130551 APPENDIX A TOSHIBA UPS INFORMATION

City of Leesburg, Florida I.T. Data Center 130551 APPENDIX A TOSHIBA UPS INFORMATION City of Leesburg, Florida I.T. Data Center 130551 APPENDIX A TOSHIBA UPS INFORMATION This Appendix A includes technical documents and specifications for the Toshiba 4200 FA 30 kva Uninterruptable Power

More information

Increase the efficiency of power distribution in your high-density data center

Increase the efficiency of power distribution in your high-density data center Increase the efficiency of power distribution in your high-density data center Abstract As power density in modern data centers increases, more focus has been placed on improving efficiency in the power

More information

Eaton epdu. Intelligent and flexible power distribution

Eaton epdu. Intelligent and flexible power distribution Eaton epdu Intelligent and flexible power distribution Introduction and overview With today s changing technology, increasing power demands and the need for reliability, data centre professionals require

More information

SCADA Controlled Multi-Step Automatic Controlled Capacitor Banks & Filter Banks

SCADA Controlled Multi-Step Automatic Controlled Capacitor Banks & Filter Banks SCADA Controlled Multi-Step Automatic Controlled Capacitor Banks & Filter Banks Introduction SCADA (Supervisory Controlled and Data Acquisition) controlled multi-step metalenclosed automatic capacitor

More information

SG Series UPS 225-750 kva. with ultra-high efficiency eboost technology

SG Series UPS 225-750 kva. with ultra-high efficiency eboost technology SG Series UPS 225-750 kva with ultra-high efficiency eboost technology Touching all Areas of the Energy Industry With more than 100,000 employees in over 100 countries, GE s diverse portfolio of products

More information

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation Basis of Design This section applies to the design relating to low voltage switchboards. Design Criteria UW Class N1 facilities main switchboards shall be rear accessible. The main, tie and feeder breakers

More information

QUESTIONS and ANSWERS RFB 745-15-9894, Metal Clad Switchgear and Power Control Room

QUESTIONS and ANSWERS RFB 745-15-9894, Metal Clad Switchgear and Power Control Room QUESTIONS and ANSWERS RFB 745-15-9894, Metal Clad Switchgear and Power Control Room 1) When you click on the UTHSCSA Drawing the site takes you to the E-1 drawing no other. Will there be other drawings

More information

Parallel Redundant Uninterruptible Power Supply

Parallel Redundant Uninterruptible Power Supply 9 315 Parallel Redundant Uninterruptible Power Supply Installation/Operation Manual 164202013 Rev. D ------------------------------------------------------------------------ ------------------------------------------------------------------------

More information

Simple Electrical Utility Cost Allocation Solutions

Simple Electrical Utility Cost Allocation Solutions Simple Electrical Utility Cost Allocation Solutions PowerLogic High Density Metering Advanced Submetering and Multi-Tenant Metering Buildings Retail Multi Residential DATA CENTER SOLUTIONS For More Information:

More information

Project Name: Nortrax Section 26 41 00 Project No: 13-013 SURGE PROTECTION DEVICES Page 1

Project Name: Nortrax Section 26 41 00 Project No: 13-013 SURGE PROTECTION DEVICES Page 1 Page 1 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. General: Drawings and general provisions of the Contract, including General and Supplementary Conditions and Divisions 1 Specification sections apply to

More information

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars Presented By: Greg Pelster & Robert Schmid FFI Ferrie, Franzmann Industries LOW VOLTAGE SWITCHGEAR & LOW VOLTAGE

More information

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out APC Matrix-UPS, 3750 Watts / 5000 VA,Input 208V / Output 120V, 208V, Interface Port DB-9 RS-232, SmartSlot, Extended runtime model Includes: CD with software,

More information

SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL SECTION 26 09 13 - POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL 1.1 SUMMARY A. This section describes the requirements for the installation of Power Monitors and associated

More information

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000 Description Firetrol FTA1000 Full Voltage Fire Pump Controllers are intended for use with electric motor driven fi re pumps

More information

Suitable for Emergency, Peak and Prime Power System Applications. Low Voltage Automatic Transfer Switch Systems

Suitable for Emergency, Peak and Prime Power System Applications. Low Voltage Automatic Transfer Switch Systems Suitable for Emergency, Peak and Prime Power System Applications Low Voltage Automatic Transfer Switch Systems THE POWER AUTHORITY THE POWER AUTHORITY ASCO s experience and commitment to excellence in

More information

CRITICAL POWER MONITORING CPM20/CPM21 DETAILS

CRITICAL POWER MONITORING CPM20/CPM21 DETAILS CRITICAL POWER MONITORING CPM20/CPM21 DETAILS The Starline Critical Power Monitor (CPM) is a distributed data acquisition system that enables Current and Power monitoring in busway systems. Each phase

More information

DC Power Solutions Overview. DC Power Solutions for EVERY Network Application.

DC Power Solutions Overview. DC Power Solutions for EVERY Network Application. DC Power Solutions Overview DC Power Solutions for EVERY Network Application. DC Power Solutions for Every Network Application Eaton recognizes the challenges that are unique to different customers applications.

More information

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features: Application : RISH Master 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network & replaces the multiple analog

More information

Racks & Enclosures. Deliver. Design. Define. Three simple words that clearly describe how we approach a Data Center project.

Racks & Enclosures. Deliver. Design. Define. Three simple words that clearly describe how we approach a Data Center project. Three simple words that clearly describe how we approach a Data Center project. Eclipse Racks & Enclosures DELIVERING THE RIGHT INFRASTRUCTURE FOR YOUR MISSION-CRITICAL NEEDS SERVER RACKS & NETWORKING

More information

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5

AMFA-27 AMFA-29. Operator s Manual & Installation Instructions. Rev. 2.5 AMFA-27 AMFA-29 Operator s Manual & Installation Instructions Rev. 2.5 Date: 17 July, 2010 Permanently-connected, utility Interactive, single-phase, inverters Model AMFA-27 WIND TURBINE INVERTER (240 VAC

More information

RELIABLE AND FLEXIBLE POWER FOR YOUR DATA CENTRE

RELIABLE AND FLEXIBLE POWER FOR YOUR DATA CENTRE RELIABLE AND FLEXIBLE POWER FOR YOUR DATA CENTRE Highly efficient solutions for power distribution, management and monitoring POWER DISTRIBUTION WIRE-FREE MONITORING LEAK DETECTION Daxten provides comprehensive

More information

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument 4921210109D 7000/7000C/7020 Multi-instrument 4921210109D Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Demand on each phase current Accuracy U, I and F class 0.5 Other values

More information

How To Power A Bladecenter H Servers

How To Power A Bladecenter H Servers Solutions Guide for IBM Data Center Architecture: IBM BladeCenter H Servers In today s high-demand enterprise environment, organizations need a reliable infrastructure to run compute-intensive applications

More information

4.0 UPS dedicated to ICT for unmatched energy savings

4.0 UPS dedicated to ICT for unmatched energy savings 4.0 UPS dedicated to ICT for unmatched energy savings Introducing UPSaver by Borri, a new modular UPS series for the ICT industry, totally configurable, quickly scalable, with high efficiency and low TCO.

More information

EQUIPMENT SPECIFICATIONS

EQUIPMENT SPECIFICATIONS EQUIPMENT SPECIFICATIONS IC-1600 Intelligent Controller The IC-1600 Intelligent Controller is a fully intelligent panel that has a complete database on board. It operates in conjunction with the Access

More information

Eaton s E-Series protective relay family

Eaton s E-Series protective relay family E-Series protective relays Feeder distribution relays Motor relays Transformer relays Generator relays Eaton s E-Series protective relay family Microprocessor-based design Eaton s E-Series relay family

More information

SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC INTEGRATED SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671A SECTION 16671A

SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC INTEGRATED SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671A SECTION 16671A SURGE PROTECTIVE DEVICES (SPDs) INTEGRATED UNITS LOW VOLTAGE AC SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS PART 1 GENERAL 01 02 03 SCOPE The Contractor shall furnish and install the Surge Protective

More information

MCC Ratings. Voltage Rating

MCC Ratings. Voltage Rating MCC Ratings In addition to the various ratings of individual components used in motor control centers, the overall ratings of the motor control center must also be considered. Voltage Rating Motor control

More information

PowerGem Pro Uninterruptible Power Supply

PowerGem Pro Uninterruptible Power Supply Uninterruptible Power Supply User-friendly Intelligent Ultra reliable Range The Most Intelligent On-Line Double Conversion Power Protection System The range achieves higher reliability and greater immunity

More information

NO-BREAK KS 7e. Concentrated Energy. 2750 kva (50Hz) 3000 kva (60Hz) DIESEL ROTARY UNINTERRUPTIBLE POWER SUPPLY SYSTEM

NO-BREAK KS 7e. Concentrated Energy. 2750 kva (50Hz) 3000 kva (60Hz) DIESEL ROTARY UNINTERRUPTIBLE POWER SUPPLY SYSTEM NO-BREAK KS 7e Concentrated Energy e 2750 kva (50Hz) 3000 kva (60Hz) DIESEL ROTARY UNINTERRUPTIBLE POWER SUPPLY SYSTEM Data Centre owners, operators and designers are required to meet ever increasing and

More information

Increasing safety, reliability and efficiency for today s data centers

Increasing safety, reliability and efficiency for today s data centers Increasing safety, reliability and efficiency for today s data centers Products and expertise for data center success Drawing upon vast experience in complex industries where uptime is critical, ABB provides

More information

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply APC Smart-UPS RT GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply PART 1 - GENERAL 1.1 SUMMARY A. This specification describes the operation and functionality

More information

Alternative data center power

Alternative data center power Alternative data center power A quantitative TCO comparison of 400V AC and 600V AC power systems Abstract Power efficiency has become a critical focus for IT and facilities managers as they struggle to

More information

Cisco Nexus 7000 Series Power Supply Modules

Cisco Nexus 7000 Series Power Supply Modules Cisco Nexus 7000 Series Power Supply Modules Product Overview The Cisco Nexus 7000 Series Power Supply Modules (Figures 1 and 2) deliver fault tolerance, high efficiency, load sharing, and hot-swappable

More information

A Scalable, Reconfigurable, and Efficient Data Center Power Distribution Architecture

A Scalable, Reconfigurable, and Efficient Data Center Power Distribution Architecture A Scalable, Reconfigurable, and Efficient Data Center Power Distribution Architecture By Neil Rasmussen White Paper #129 Executive Summary Significant improvements in efficiency, power density, power monitoring,

More information

Data center solutions Medium & large enterprise, multi-tenant and hyperscale. Energize your data center, maximize the value of your investment

Data center solutions Medium & large enterprise, multi-tenant and hyperscale. Energize your data center, maximize the value of your investment Data center solutions Medium & large enterprise, multi-tenant and hyperscale Energize your data center, maximize the value of your investment We serve the needs of data centers of all sizes, around the

More information

Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management

Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management Energy Depot GmbH Delivering Solutions for Energy Management PRODUCT AND APPLICATION GUIDE Total Monitoring Solution for PV SOLAR LOGGER & ANALYSIS DC STRING MONITORING Residential Comprehensive Solar

More information

in widespread use with Simplex sister Company, Simplex Onsite, providing nationwide load bank rentals.

in widespread use with Simplex sister Company, Simplex Onsite, providing nationwide load bank rentals. 600KW - 1250KW Overview Integrated design, load module, trailer, reels, cam-lock style connections, digital control High capacity, 600-1250kw Dual voltage: 208-240/416-480vAC Digital load control, 5 kw

More information

A Scalable, Reconfigurable, and Efficient Data Center Power Distribution Architecture

A Scalable, Reconfigurable, and Efficient Data Center Power Distribution Architecture A Scalable, Reconfigurable, and Efficient Data Center Power Distribution Architecture White Paper 129 Revision 1 by Neil Rasmussen > Executive summary Significant improvements in efficiency, power density,

More information

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C COOLS conditioned server - racks for direct installation into the room COOLSIDE box INVERTER R410A E C 2 COOLSIDE box GENERAL FEATURES COOLSIDE BOX is a split system consisting of an outdoor motocondensing

More information

Inverter / Charger Installation General Operations and AC and DC Connections

Inverter / Charger Installation General Operations and AC and DC Connections Inverter / Charger Installation General Operations and AC and DC Connections The Inverter is just one piece. Sometimes, a tendency is to mount the inverter and batteries, and make it work It is better

More information

LOXONE 12 Channel Amplifier

LOXONE 12 Channel Amplifier LOXONE 12 Channel Amplifier Item no.: 200110 Thank you for purchasing the Loxone Twelve Channel Amplifier. The versatility of the Amplifier makes it the perfect choice for almost every type of custom multi-room

More information

ELECTRICAL ENGINEERING DESIGN CRITERIA APPENDIX F

ELECTRICAL ENGINEERING DESIGN CRITERIA APPENDIX F ELECTRICAL ENGINEERING DESIGN CRITERIA APPENDIX F TABLE OF CONTENTS Appendix F - Electrical Engineering Design Criteria F.1 Introduction...F-1 F.2 Codes and Standards...F-1 F.3 Switchyard and Transformers...F-1

More information

ASCO SERIES 185 Power Transfer Switches

ASCO SERIES 185 Power Transfer Switches ASCO SERIES 185 Power Transfer Switches 4-hour protection no matter when trouble strikes ASCO Series 185 Power Transfer Switches An Automatic Transfer Switch helps prevent... Your business or home from

More information

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4 CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,

More information

Eaton 93PM UPS Efficient. Scalable. Innovative.

Eaton 93PM UPS Efficient. Scalable. Innovative. Product rochure 20-200 kw aton UPS fficient. Scalable. nnovative. features and benefits The aton UPS combines unprecedented and reliability with an eye-catching design. space-saving, scalable and flexible

More information

DATA CENTER UNIQUE CHARACTERISTICS AND THE ROLE OF MEDIUM VOLTAGE VACUUM CIRCUIT BREAKERS

DATA CENTER UNIQUE CHARACTERISTICS AND THE ROLE OF MEDIUM VOLTAGE VACUUM CIRCUIT BREAKERS DATA CENTER UNIQUE CHARACTERISTICS AND THE ROLE OF MEDIUM VOLTAGE VACUUM CIRCUIT BREAKERS ABSTRACT Data Centers are a critical part of the world economic systems. Billions of electronic transactions happen

More information

Server Technology Intl.

Server Technology Intl. Server Technology, Inc. 3-Phase Power in the Data Center White Paper STI-100-005 North America/ASIA EMEA Server Technology, Inc. Server Technology Intl. 1040 Sandhill Drive Sienna Court Reno, NV 89521

More information

30-120 3 Phase Modular Finally the benefits of Modular ups are for all

30-120 3 Phase Modular Finally the benefits of Modular ups are for all MUST 30-120 3 Phase Modular UPS Finally the benefits of Modular ups are for all MUST 30-120 MUST means Modular UPS System Three-phase MUST 30-120 is an uninterruptible power supply with double conversion

More information

Power Distribution in Data Centers: STARLINE Track Busway, PX ipdus and Power IQ

Power Distribution in Data Centers: STARLINE Track Busway, PX ipdus and Power IQ Power Distribution in Data Centers: STARLINE Track Busway, PX ipdus and Power IQ 2011 Raritan Inc. Overview Data center managers are faced with increasingly challenging demands: supplying additional computing

More information

Manufacturers' Representatives Specializing in Electrical, Electronic and Datacom Products & Services

Manufacturers' Representatives Specializing in Electrical, Electronic and Datacom Products & Services SPS/TSC Strategic Protection Systems/Tubbesing Sales Corp. Manufacturers' Representatives Specializing in Electrical, Electronic and Datacom Products & Services American Power Conversion Single-Phase and

More information

Magnum Mobile Generator MMG55 Specifications

Magnum Mobile Generator MMG55 Specifications Empowering Real People Magnum Mobile Generator MMG55 Specifications ENGINE John Deere PE5030TF270 - turbocharged, diesel engine o Prime - 72 hp @ 1800 rpm o Standby - 80 hp @ 1800 rpm o 4 cylinder o 3.0

More information

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Metering and Monitoring. Basis of Design

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Metering and Monitoring. Basis of Design Basis of Design This section applies to the design, installation and integration of metering and monitoring equipment, including: hardware installed in the electrical service and distribution equipment,

More information

LEVEL 3 DATA CENTER ASSESSMENT

LEVEL 3 DATA CENTER ASSESSMENT Nationwide Services Corporate Headquarters 410 Forest Street Marlborough, MA 01752 USA Tel: 800-342-5332 Fax: 508-303-0579 www.eecnet.com LEVEL 3 DATA CENTER ASSESSMENT Submitted by: Electronic Environments

More information

Learning Module 13: Panelboards and Switchboards. 101 Basic Series

Learning Module 13: Panelboards and Switchboards. 101 Basic Series Learning Module 13: Panelboards and Switchboards 101 Basic Series What You Will Learn We ll step through each of these topics in detail: Introduction 4 Definitions 4 Similarities Between Panelboards and

More information

San Diego Community College District

San Diego Community College District San Diego Community College District District-Wide Smart Metering Guidelines for NEW & RENOVATED BUILDINGS City College, Mesa College, and Miramar College Prepared by: Randall Lamb September 20, 2011 Revised:

More information

SmartOnline 200-240V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

SmartOnline 200-240V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire SmartOnline 200-240V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire MODEL NUMBER: SU6000RT3UHV Highlights 6000VA / 6kVA / 4200W on-line double-conversion

More information

Tmax MCCBs. Molded case circuit breakers. Tmax

Tmax MCCBs. Molded case circuit breakers. Tmax Molded case circuit breakers Introduction ABB is once again demonstrating its commitment to new product development and its superiority in product performance. Never before has the industry seen such high

More information

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches PART 1 GENERAL 1.01 Scope Optional Standby Power Generator Systems A. Furnish and install automatic transfer switches

More information