Line Sensor LED Lights Catalog. 1 Vol.

Size: px
Start display at page:

Download "Line Sensor LED Lights Catalog. 1 Vol."

Transcription

1 Line Sensor LED Lights Catalog 1 Vol. CCS Inc.

2 Line up Line Sensor LED Lights LineUp LNSP series Reflection type Illuminating mechanism Achieve high output illumination with controlled diffusion due to this unique illuminating mechanism. Because light does not easily diffuse, there is little loss for the amount of light, allowing for illumination over long distances. This product Camera LED Rod lens P.7 Inspected object Natural air cooling with a brightness of 4, lx, the highest level in the industry.* By controlling light diffusion through the unique illuminating mechanism, there is little change in the brightness due to distance, allowing you to flexibly set the distance between the inspected item and the light. The can be made from a minimum of 1 mm up to a maximum of 1,mm, in 1 mm increments. * Measured values with an illuminating distance of 5 mm LNHKSTK series Reflection type Illuminating mechanism Illuminated light from the LED is passed through a cylindrical lens at the tip, thus illuminating a convergent line of light. Camera This product P.11 LED Cylindrical lens Inspected object A cylindrical lens allows for illuminating with a convergent line of light. There are two types of s: 6 mm or 2 mm. By changing the position of the lens unit on the tip, you can freely set the converging or the converging width for the illuminated light. 1

3 HLND series R type Reflection type Illuminating mechanism Achieve high output by employing unique radiating and illuminating mechanisms. The can be made up to 2,7 mm long. Camera LED This product P.15 Inspected object Achieve the optimal high output as reflection lighting by using a diffusion plate with a high transmittance rate. Supports use with higher brightness than the Ttype (transmission lighting) of the same series. The can be made from a minimum of 1 mm up to a maximum of 2,7 mm, in 1 mm increments. HLND series T type Transmission type Illuminating mechanism Achieve high uniformity by employing unique radiating and illuminating mechanisms. The can be made up to 2,7 mm long. Camera Inspected object LED P.19 This product Achieve the optimal uniformity as transmission lighting by using a diffusion plate with a high diffusion rate. Supports use with higher uniformity than the Rtype (reflection lighting) of the same series. The can be made from a minimum of 1 mm up to a maximum of 2,7 mm, in 1 mm increments. LT series Transmission type Illuminating mechanism By employing a mechanism where the sticks out from the main unit, it's possible to illuminate with the tip near the inspected item, even in a narrow space. Camera Inspected object This product P.23 LED Achieve both high uniformity and high brightness through this unique optical system. It can perform highlyaccurate inspections, as well as handle highspeed scan rates as well. The can be made from a minimum of 1 mm up to a maximum of 1,8mm, in 1 mm increments. 2

4 Selection guide Selecting for Application by Industry Plastic film and glass industry Inspecting for scratches on transparent film Plastic film and glass industry Inspecting for fish eyes, scratches, and foreign materials on transparent film LNSP series P.7 LT series P.23 Plastic film and glass industry Inspecting for foreign objects on transparent film Papermaking industry Inspecting alignment for label seals HLND series T type P.19 LNSP series P.7 Nonwoven fabric industry Inspecting for faults in nonwoven fabrics Food product industry Inspecting for foreign materials mixed in rice LNHKSTK series P.11 HLND series R type P.15 3

5 Substrates and electronics industry Inspecting the exterior of substrates equipped with electronic parts Substrates and electronics industry Inspecting for cracks and damage in wafers LNSP series P.7 LT series P.23 Substrates and electronics industry Inspecting the exterior of film substrates Mechanical parts industry Inspecting for scratches and dents in motor axles LNHKSTK series P.11 HLND seriest type P.19 Metal industry Inspecting the exterior of metal foil sheets Steel plate industry Inspecting the exterior of colored steel plates LT series P.23 HLND series R type P.15 4

6 Lighting selection guide Selecting based on lighting characteristics If selecting based on illuminance or costeffectiveness... If selecting based on convergence... Uniformity of the Uniformity of the Low High Uniformity of the emitting surface Low High Uniformity of the emitting surface LNSP series P.7 LNHKSTK series P.11 If selecting based on supported... If selecting based on supported... Uniformity of the Uniformity of the Low High Uniformity of the emitting surface Low High Uniformity of the emitting surface HLND series R type P.15 HLND series T type P.19 If selecting based on brightness, uniformity of the emitting surface, or diffusion... Uniformity of the High Low Uniformity of the emitting surface LT series P.23 Conditions for comparing each light : Comparison of measured values 1 mm away from the light's : Comparison using our measurement conditions Uniformity of the : Comparison of measured values 1 mm away from the light's with the lens focal point aligned : Comparison using our measurement conditions : Comparison using our measurement conditions : Comparison using the product lineup : Comparison using standard price for a 2 mm *Data listed here are actually measured values. Results may vary for individual units. 5

7 Uniformity of the LNSP LNHKSTK HLNDR HLNDT LT Low High Low High Low High Low High LNSP LNHKSTK HLNDR HLNDT LT Low High Low High Low High LNSP HLNDR LT Uniformity of the HLNDT LNHKSTK 6, 5, Graph of the change in illuminance of line sensor lighting LNSP 4, (lx) 3, 2, LT HLNDR LNHKSTK 1, HLNDT Illuminating distance (mm) 6

8 7mm Reflection type LSNP series LNSP Series Direct Number Direct No. 15 Achieved brightness of 4, lx *1 with a natural air cooling type Line sensor lighting that achieves both high output and compact size *1. Actual measurement values at a 5 mm illumination distance, current as of our inhouse inspection in September of 211. LNSP6SW of 4, lx *1, the top class in the industry Through our unique illuminating mechanism, we achieved a brightness of 4, lx, the top class in the industry for natural air cooling types. Graph of the change in illuminance Achieving both high output and compact space We achieved a compact design compared to general, high output line sensor LED lights. Compact design (lx) 6, 5, 4, 3, 2, Change in illuminance from the LNSP3SW 42 mm Size of general, high output line sensor LED lights 1, Illuminating distance (mm) * Actual measurement values at 1% intensity in each illuminating distance. (Results may vary for individual units.) Providing a stable inspection environment We provide a stable examination environment. The light stabilizes about 3 minutes after being turned on, and furthermore, the output variance is low. Graph of the change in brightness over time Relative brightness (%) Change in brightness over time for the LNSP3SW Time (Min) * Actual measurement values at 1% intensity at an ambient temperature of 25 C. (Results may vary for individual units.) Lighting characteristics The following radar chart introduces the LNSP Series' characteristics. Lighting characteristics radar chart Uniformity of the Low High Stabilized approx. 3 minutes after it lit up Uniformity of the emitting surface Weight 1,9 g For the LNSP3SW Saving space for your inspection environment By making the light more compact, we contribute to saving space in your inspection environment or equipment environment. Spacesaving environment LNSP Series Enables short distance illumination Saves space Illuminating mechanism Camera Achieve high output illumination with controlled diffusion due to this unique illuminating mechanism. Because light does not easily diffuse, there is little loss for the amount of light, allowing for illumination over long distances. Figure of the LNSP's illuminating mechanism Using special This product radiating mechanism LED Rod lens Camera Inspected object 7 LNSP Series Direct Number Direct No. 15 You can easily access the product information page you want just by inputting the 7digit number in the direct number input space from CCS s website (Machine Vision Application page). The direct number is included on the Lineup of each product page.

9 Uniformity of the Applications We use high output and uniform illumination to provide optimal imaging for a wide variety of objects, from glossy test material to objects with diffusion. Also, because the illuminated light is wide, it's easy to align the camera. Inspecting alignment for label seals Inspecting the exterior of substrates equipped with electronic parts Inspecting for scratches on transparent film Data Measurement data for the LNSP3SW (Data listed here are actual measurement values. Results may vary for individual units.) (lx) Relative (%) Graph of the distribution of illuminance Lateral position (mm) Lateral position (mm) 6, 5, 4, 3, 2, 1, distribution * Actual measurement values at 1% intensity with an illuminating distance of 1 mm. Graph of the change in illuminance Change in illuminance Illuminating distance (mm) Intensity scales (Steps) * Actual measurement values at 1% intensity at each illuminating distance. * Actual measurement values when using analog Control Unit, PSB3324. Relative brightness (%) Graph of the distribution of brightness Graph of output characteristics distribution * Actual measurement values at 1% intensity with an illuminating distance of 1 mm. Radiation amount (%) Output characteristics Information about Web Member registration If you register as a member on our website, you can download various materials, such as 3DCAD drawings and instruction guides. Also, we accept applications for lighting selections and free demo products from our contact page. Please feel free to use it. 8

10 Reflection type LSNP series LNSP Series Direct Number Direct No. 15 Lineup Direct number Model LED color Emitting Power consumption Applicable Weight (max.) surface (max.) Control Unit Dimensions LNSP1SW LNSP2SW LNSP3SW LNSP4SW LNSP5SW 1mm 2mm 3mm 4mm 5mm 21W 41W 61W 81W 11W 43g 76g 1,9g 1,42g 1,74g PSB LNSP6SW LNSP7SW LNSP8SW LNSP9SW LNSP1SW 6mm 7mm 8mm 9mm 1,mm 121W 142W 162W 182W 22W 2,7g 2,4g 2,73g 3,5g 3,38g Common specifications LED color Correlated color temperature Input voltage Connector Polarity/signal (SW) 5,8 K (typ.) DC24V (max.) Metal connector: SRCN1A167P (Made by Japan Aviation Electronics Industry, Limited) 1, 2, 3: (+), 4, 5, 6: ( ), 7: NC Cable Case material Operating environment Storage environment Cooling method.3 m Emitting surface: Acrylic, Base: Aluminum alloy, Side plate: PC Temperature: to 4 C, Humidity: 2 to 7%RH (with no condensation) Temperature: 1 to 6 C, Humidity: 2 to 7%RH (with no condensation) Natural air cooling Light spectrum 1 9 Relative radiation strength (%) Wave (nm) Be sure to read the "Instruction Guide" included with the product before use and observe cautionary information. Dimensions (mm) 1 LNSP (1 n)sw *n = Number from 1 to 1 21 () 8 (1 n)+26: Full (1 n): Emitting surface (18) 42 Detailed figure C (Ø6.9) Metal connector 7P 55 3 For installation 4M5 nut slot Detailed figure C 9 LNSP Series Direct Number Direct No. 15 You can easily access the product information page you want just by inputting the 7digit number in the direct number input space from CCS s website (Machine Vision Application page). The direct number is included on the Lineup of each product page.

11 Uniformity of the Applicable Control Unit PSB3324 Direct number Model 2762 PSB3324 Applicable light No. of channels 3W 1 P.27 Options Extension cable This cable connects the light and the Control Unit. You can choose from 2 m, 3 m, 5 m, 1 m, and 2 m. Direct number Model FCB21.25SQME7 FCB31.25SQME7 FCB51.25SQME7 FCB11.25SQME7 FCB22.SQME7 Cable 2 m 3 m 5 m 1 m 2 m Dimensions (mm) FCBn1.25SQME7 (n=2, 3, 5, 1) FCB22.SQME7 (1 n) 2 Ø1.6 Ø1.6 Ø11.7 Ø1.6 Information about Web Member registration If you register as a member on our website, you can download various materials, such as 3DCAD drawings and instruction guides. Also, we accept applications for lighting selections and free demo products from our contact page. Please feel free to use it. 1

12 Reflection type LNHKSTK series LNHKSTK Series Direct Number Direct No. 129 Illuminating converged line light Cylindrical lens allows for convergent illumination without wasting any light LN2SWHKSTK LN6SWHKSTK Achieving high output using unique lighting technology We achieved high output with low power consumption using our unique radiation mechanism and optical design. Graph of the change in illuminance Illuminating converged line light A cylindrical lens allows for convergent illuminance without wasting any light. image for the LN2SWHKSTK 25, Change in illuminance for the LN2SWHKSTK (lx) 2, 15, 1, 5, Illuminating distance (mm) * Actual measurement values at 1% intensity in each illuminating distance. (Results may vary for individual units.) You can freely set the converging and converging width By changing the position of the lens unit on the tip, you can freely set the converging or the converging width for the illuminated light. The lens unit can be moved. A coaxial unit can be installed Install the optional coaxial unit to use coaxial illumination. A coaxial unit can be installed. Converging width (Thin) Converging width (Wide) Coaxial unit Lighting characteristics The following radar chart introduces the LNHKSTK Series' characteristics. Illuminating mechanism Page 33 contains examples with the coaxial unit installed. Illuminated light from the LED is passed through a cylindrical lens at the tip, thus illuminating a convergent line of light. Lighting characteristics radar chart Figure of the LNHKSTK illuminating mechanism Using special radiating mechanism Uniformity of the This product Camera Low High Uniformity of the emitting surface LED Cylindrical lens Inspected object 11 LNHKSTK Series Direct Number Direct No. 129 You can easily access the product information page you want just by inputting the 7digit number in the direct number input space from CCS s website (Machine Vision Application page). The direct number is included on the Lineup of each product page.

13 Uniformity of the Applications By changing the position of the lens unit on the tip, you can freely set the converging or the converging width for the illuminated light. Efficient convergence allows for optimal imaging even with relatively little power consumption. Inspecting the exterior of film substrates Inspecting for faults in nonwoven fabrics Data Measured data for the LN2SWHKSTK (Data listed here are actual measurement values. Results may vary for individual units.) Relative (%) , 2, 15, 1, 5, distribution Change in illuminance Illuminating distance (mm) Relative brightness (%) Lateral position (mm) Lateral position (mm) * Actual measurement values at 1% intensity with an illuminating distance of 1 mm (With the custom optional diffusion film installed). (lx) Graph of the distribution of illuminance Graph of the change in illuminance * Actual measurement values at 1% intensity with an illuminating distance of 1 mm (With the custom optional diffusion film installed). Change the brightness distribution by moving the lens unit's position. Radiation amount (%) Graph of the distribution of brightness Graph of output characteristics distribution Output characteristics Input voltage (V) * Actual measurement values at 1% intensity at each illuminating distance. * Actual measurement values when using analog Control Unit, PSB324VB. Information about Web Member registration If you register as a member on our website, you can download various materials, such as 3DCAD drawings and instruction guides. Also, we accept applications for lighting selections and free demo products from our contact page. Please feel free to use it. 12

14 Reflection type LNHKSTKseries LNHKSTK Series Direct Number Direct No. 129 Lineup Emitting surface Power consumption Applicable Direct number Model LED color (max.) Weight (max.) Control Unit* Dimensions 1312 LN6SWHKSTK 6mm 6.1W 25g PD33243 series LN2SWHKSTK 2mm 22W 75g PSB series 2 *Regarding applicable Control Unit: The digital Control Unit PD33243 Series controls light intensity through pulse width modulation (PWM). Please evaluate your actual inspection environment before making a selection. Common specifications LED color Correlated color temperature Input voltage (SW) 5,5K (typ.) DC24V (max.) Cable Case material Operating environment.3 m Aluminum alloy Temperature: to 4 C, Humidity: 2 to 85%RH (with no condensation) Connector SMR3VB 1 Storage environment Temperature: 2 to 6 C, Humidity: 2 to 85%RH (with no condensation) Polarity/signal 1: Anode (+) Brown, 2: NC, 3: Cathode ( ) Blue Cooling method Natural air cooling Light spectrum 1 9 Relative radiation strength (%) Wave (nm) Be sure to read the "Instruction Guide" included with the product before use and observe cautionary information. Dimensions (mm) 1 LN6SWHKSTK 2 LN2SWHKSTK M3 tap depth 6 (For installation) M2 tap depth 4 (For installation) M2 tap depth 4 (For installation) M3 tap depth 6 (For installation) Adjusting screws 82 to Adjusting screws 82 to SM Connector 3P SM Connector 3P M4 tap depth 8 (For installation) M4 tap depth 8 (For installation) LNHKSTK Series Direct Number Direct No. 129 You can easily access the product information page you want just by inputting the 7digit number in the direct number input space from CCS s website (Machine Vision Application page). The direct number is included on the Lineup of each product page.

15 Uniformity of the Applicable Control Unit Digital Control Unit PD33243 series PD33243PI PD33243SI PD33243EI Direct number Model 2775 PD33243PI Applicable light No. of channels Direct number Model Applicable light No. of channels Direct number Model Applicable light No. of channels 24V 28W PD33243SI 24V 28W PD33243EI 24V 28W 3 P.29 P.29 P.29 Analog Control Unit PSB series PSB124VB PSB324VB PSB124VWW Direct number Model Applicable light 2194 PSB124VB 24V 1W PSB324VB 24V 3W PSB124VWW 24V 1W 1 Options P.31 Coaxial unit Install on the LNHKSTK series light to use coaxial illumination. No. of channels Direct number Model Applicable light No. of channels Direct number Model Applicable light P.31 No. of channels P.31 Dimensions (mm) KTVLN6 (For the LN6SWHKSTK) KTVLN2 (For the LN2SWHKSTK) φ3.6 (For light installation) 2M3.5 depth 4 (For installation) φ3.6 (For light installation) 3M3.5 depth 4 (For installation) Extension cable The cable included with the light is 3 cm. Use an extension cable to match your installation environment. FCB Direct number Model FCB1 FCB2 FCB3 FCB5 Cable 1 m 2 m 3 m 5 m Application Used when extending the space between the light and the Control Unit. Cable diameter: Ø4.8 mm Flexible cable It can even withstand tests where it is bent 1 million times. FRCB Direct number Model FRCB1 FRCB2 FRCB3 FRCB5 Cable diameter: Ø4.8 mm Cable 1 m 2 m 3 m 5 m Use this cable with excellent endurance when extending the space between the Application light and the Control Unit. * If using flexible cables, affix the cable section on the light side (including the connector section). Caution: If you join cables for a over 5 m, the intensity may be unstable. Information about Web Member registration If you register as a member on our website, you can download various materials, such as 3DCAD drawings and instruction guides. Also, we accept applications for lighting selections and free demo products from our contact page. Please feel free to use it. 14

16 Reflection type HLND series Rtype HLND Series RType Direct Number Direct No. 128 We can make s up to 2,7 mm Line sensor lighting with both high output and support HLND3RDR HLND3SW2R HLND6SW2R HLND6RDR We can make s from a minimum of 1 mm up to a maximum of 2,7 mm The HLND Series provides light with the optimal to meet your needs. Because we manufacture the product joining the LED panels, we can manufacture the in 1 mm increments. You can specify a maximum of 2,7 mm. Also, we used aluminum alloy as the material for the chassis, and ensured sufficient strength through integral extrusion. HLND1 Emitting surface from a minimum of 1 mm, in increments of 1 mm HLND27 You can specify the for the up to a maximum of 2,7 mm Rtype, optimal as reflection lighting The HLND series Rtype achieves the optimal high output as reflection lighting. Also, the LED can emit white light or red light. Select your light based on your needs. High quality design you can use stably This light displays stable performance over a long period by using a radiation mechanism that prevents the temperature from rising due to the heat emitted by the LED, as well as a mechanism for efficient illumination. Rtype (Reflection lighting) Using a radiating mechanism Using metal connectors Achieve the optimal high output as reflection lighting by using a diffusion plate with a high transmittance rate. You can use higher brightness than the Ttype (transmission lighting) of the same series. Lighting characteristics The following radar chart introduces the HLND Series' Rtype's characteristics. Illuminating mechanism Achieve high output by employing unique radiating and illuminating mechanisms. Lighting characteristics radar chart Uniformity of the Figure of HLNDR's illuminating mechanism Using special radiating mechanism Camera LED Low High Uniformity of the emitting surface This product Inspected object 15 HLND Series RType Direct Number Direct No. 128 You can easily access the product information page you want just by inputting the 7digit number in the direct number input space from CCS s website (Machine Vision Application page). The direct number is included on the Lineup of each product page.

17 Uniformity of the Applications We ensured optimal brightness by using a diffusion plate with a high transmittance rate. It's optimal for imaging in a dark field using scattered light. Inspecting for foreign materials mixed in rice Inspecting the exterior of colored steel plates Data Measured data for the HLND3SW2R (Data listed here are actual measurement values. Results may vary for individual units.) Graph of the distribution of illuminance Graph of the distribution of brightness distribution distribution 1 1 Relative illuminance (%) Relative brightness (%) Lateral position (mm) Lateral position (mm) * Actual measurement values at 1% intensity with an illuminating distance of 1 mm. * Actual measurement values at 1% intensity with an illuminating distance of 1 mm. (lx) Graph of the change in illuminance Change in illuminance 3, 25, 2, 15, 1, 5, Illuminating distance (mm) * Actual measurement values at 1% intensity at each illuminating distance. Radiation amount (%) Graph of output characteristics Output characteristics Intensity scales (Steps) * Actual measurement values when using analog Control Unit, PSB3324. Information about Web Member registration If you register as a member on our website, you can download various materials, such as 3DCAD drawings and instruction guides. Also, we accept applications for lighting selections and free demo products from our contact page. Please feel free to use it. 16

18 Reflection type HLND series Rtype HLND Series RType Direct Number Direct No. 128 Lineup Direct number Model LED color Emitting surface Power consumption (max.) Weight (max.) Applicable Control Unit Dimensions HLND1RDR HLND1SW2R 1mm 4.8W 1W 52g HLND2RDR HLND2SW2R 2mm 9.6W 2W 84g HLND3RDR HLND3SW2R 3mm 14W 3W 1,16g HLND4RDR HLND4SW2R 4mm 19W 4W 1,48g HLND5RDR HLND5SW2R 5mm 24W 5W 1,8g HLND6RDR HLND6SW2R 6mm 29W 6W 2,12g HLND7RDR HLND7SW2R 7mm 34W 71W 2,44g HLND8RDR HLND8SW2R 8mm 38W 81W 2,76g HLND9RDR HLND9SW2R 9mm 43W 91W 3,8g HLND1RDR HLND1SW2R 1,mm 48W 89W 3,4g HLND11RDR HLND11SW2R 1,1mm 53W 91W 3,75g HLND12RDR HLND12SW2R 1,2mm 58W 17W 4,4g HLND13RDR HLND13SW2R 1,3mm 62W 115W 4,36g HLND14RDR HLND14SW2R 1,4mm 67W 124W 4,68g PSB HLND15RDR HLND15SW2R 1,5mm 72W 133W 5,g HLND16RDR HLND16SW2R 1,6mm 77W 142W 6,32g 1518 HLND17RDR HLND17SW2R 1,7mm 82W 151W 5,64g HLND18RDR HLND18SW2R 1,8mm 86W 16W 5,96g HLND19RDR HLND19SW2R 1,9mm 91W 169W 6,28g HLND2RDR HLND2SW2R 2,mm 96W 178W 6,6g HLND21RDR HLND21SW2R 2,1mm 11W 186W 6,92g 1511 HLND22RDR HLND22SW2R 2,2mm 16W 195W 7,24g HLND23RDR HLND23SW2R 2,3mm 11W 24W 7,56g HLND24RDR HLND24SW2R 2,4mm 115W 213W 7,88g HLND25RDR HLND25SW2R 2,5mm 12W 222W 8,2g HLND26RDR HLND26SW2R 2,6mm 125W 231W 8,52g HLND27RDR HLND27SW2R 2,7mm 13W 24W 8,84g 17 HLND Series RType Direct Number Direct No. 128 You can easily access the product information page you want just by inputting the 7digit number in the direct number input space from CCS s website (Machine Vision Application page). The direct number is included on the Lineup of each product page.

19 Uniformity of the Common specifications LED color Correlated color temperature/ Peak wave Input voltage Connector Polarity/signal Light spectrum (SW2) (RD) Cable 6,5 K (typ.) 624 nm (typ.) Case material Aluminum alloy Operating DC24V (max.) environment Temperature: to 4 C, Humidity: 2 to 85%RH (with no condensation) Metal connector: SRCN2A167P (Made by Japan Aviation Electronics Industry, Limited) Storage environment Temperature: 2 to 6 C, Humidity: 2 to 85%RH (with no condensation) 1, 2, 3: (+), 4, 5, 6: ( ), 7: NC Cooling method Natural air cooling Relative radiation strength (%) Wave (nm) Be sure to read the "Instruction Guide" included with the product before use and observe cautionary information. Applicable Control Unit PSB3324 Direct number Model 2762 PSB3324 Applicable light 3 W No. of channels 1 P.27 Dimensions (mm) 1 HLND(1 n)r (1 n): Emitting surface 7.6 (Emitting surface) (1 n)+56.3: Full (2 n)m5 tap depth 5 Direct number Model FCB21.25SQME7 FCB31.25SQME7 FCB51.25SQME7 FCB11.25SQME7 FCB22.SQME7 Cable 2 m 3 m 5 m 1 m 2 m Dimensions (mm) FCBn1.25SQME7 (n=2, 3, 5, 1) (1 n) FCB22.SQME7 2 Ø1.6 Ø1.6 Ø11.7 Ø *n = Number from 1 to P1 (n1) 5 67 P1 (n1) 67 (n 2)+4M3 tap depth 5 29 Metal connector 7P Options Extension cable This cable connects the light and the Control Unit. You can choose from 2 m, 3 m, 5 m, 1 m, and 2 m. Information about Web Member registration If you register as a member on our website, you can download various materials, such as 3DCAD drawings and instruction guides. Also, we accept applications for lighting selections and free demo products from our contact page. Please feel free to use it. 18

20 Transmission type Direct No. 128 HLNDseriesTtype HLND Series TType Direct Number We can make s up to 2,7 mm Line sensor lighting with both uniformity and support HLND3RDT HLND3SW2T HLND6SW2T HLND6RDT We can make s from a minimum of 1 mm up to a maximum of 2,7 mm The HLND Series provides light with the optimal to meet your needs. Because we manufacture the product joining the LED panels, we can manufacture the in 1 mm increments. You can specify a maximum of 2,7 mm. Also, we used aluminum alloy as the material for the chassis, and ensured sufficient strength through integral extrusion. HLND1 Emitting surface from a minimum of 1 mm, in increments of 1 mm HLND27 You can specify the for the up to a maximum of 2,7 mm Ttype, optimal as transmission lighting The HLND series Ttype achieves the optimal uniformity for transmission lighting. Also, the LED can emit white light or red light. Select your light based on your needs. High quality design you can use stably This light displays stable performance over a long period by using a radiation mechanism that prevents the temperature from rising due to the heat emitted by the LED, as well as a mechanism for efficient illumination. Ttype (Transmission lighting) Achieve the optimal uniformity as transmission lighting by using a diffusion Using a radiating mechanism Using metal connectors plate with a high diffusion rate. You can use higher uniformity than the Rtype (reflection lighting) of the same series. Lighting characteristics The following radar chart introduces the HLND Series' Ttype's characteristics. Illuminating mechanism Achieve high uniformity by employing unique radiating and illuminating mechanisms. The can be made up to 2,7 mm long. Lighting characteristics radar chart Uniformity of the Figure of HLNDT's illuminating mechanism Using special radiating mechanism Camera Inspected object Low High Uniformity of the emitting surface LED This product 19 HLND Series TType Direct Number Direct No. 128 You can easily access the product information page you want just by inputting the 7digit number in the direct number input space from CCS s website (Machine Vision Application page). The direct number is included on the Lineup of each product page.

21 Uniformity of the Applications We achieved both brightness and uniformity by using a diffusion plate with a high diffusion rate. It's optimal for imaging in a bright field using reflected or transmitted light. Inspecting for foreign objects on transparent film Inspecting for scratches and dents in motor axles Data Measured data for the HLND3SW2T (Data listed here are actual measurement values. Results may vary for individual units.) Relative illuminance (%) Graph of the distribution of illuminance Graph of the distribution of brightness distribution distribution Lateral position (mm) Lateral position (mm) Relative brightness (%) * Actual measurement values at 1% intensity with an illuminating distance of 1 mm. * Actual measurement values at 1% intensity with an illuminating distance of 1 mm. (lx) Graph of the change in illuminance 25, 2, 15, 1, 5, Change in illuminance Illuminating distance (mm) * Actual measurement values at 1% intensity at each illuminating distance. Radiation amount (%) Graph of output characteristics Output characteristics Intensity scales (Steps) * Actual measurement values when using analog Control Unit, PSB3324. Information about Web Member registration If you register as a member on our website, you can download various materials, such as 3DCAD drawings and instruction guides. Also, we accept applications for lighting selections and free demo products from our contact page. Please feel free to use it. 2

22 Transmission type Direct No. 128 HLNDseriesTtype HLND Series TType Direct Number Lineup Direct number Emitting surface Power consumption Model LED color (max.) Weight (max.) Applicable control unit Dimensions HLND1RDT HLND1SW2T 1mm 4.8W 1W 52g HLND2RDT HLND2SW2T 2mm 9.6W 2W 84g HLND3RDT HLND3SW2T 3mm 14W 3W 1,16g HLND4RDT HLND4SW2T 4mm 19W 4W 1,48g HLND5RDT HLND5SW2T 5mm 24W 5W 1,8g HLND6RDT HLND6SW2T 6mm 29W 6W 2,12g HLND7RDT HLND7SW2T 7mm 34W 71W 2,44g HLND8RDT HLND8SW2T 8mm 38W 81W 2,76g HLND9RDT HLND9SW2T 9mm 43W 91W 3,8g HLND1RDT HLND1SW2T 1,mm 48W 89W 3,4g HLND11RDT HLND11SW2T 1,1mm 53W 91W 3,75g HLND12RDT HLND12SW2T 1,2mm 58W 17W 4,4g HLND13RDT HLND13SW2T 1,3mm 62W 115W 4,36g HLND14RDT HLND14SW2T 1,4mm 67W 124W 4,68g PSB HLND15RDT HLND15SW2T 1,5mm 72W 133W 5,g HLND16RDT HLND16SW2T 1,6mm 77W 142W 6,32g HLND17RDT HLND17SW2T 1,7mm 82W 151W 5,64g HLND18RDT HLND18SW2T 1,8mm 86W 16W 5,96g HLND19RDT HLND19SW2T 1,9mm 91W 169W 6,28g HLND2RDT HLND2SW2T 2,mm 96W 178W 6,6g 1456 HLND21RDT HLND21SW2T 2,1mm 11W 186W 6,92g HLND22RDT HLND22SW2T 2,2mm 16W 195W 7,24g HLND23RDT HLND23SW2T 2,3mm 11W 24W 7,56g 158 HLND24RDT HLND24SW2T 2,4mm 115W 213W 7,88g HLND25RDT HLND25SW2T 2,5mm 12W 222W 8,2g HLND26RDT HLND26SW2T 2,6mm 125W 231W 8,52g HLND27RDT HLND27SW2T 2,7mm 13W 24W 8,84g 21 HLND Series TType Direct Number Direct No. 128 You can easily access the product information page you want just by inputting the 7digit number in the direct number input space from CCS s website (Machine Vision Application page). The direct number is included on the Lineup of each product page.

23 Uniformity of the Common specifications LED color Correlated color temperature/ Peak wave Input voltage Connector Polarity/signal Light spectrum (SW2) (RD) Cable Case material Aluminum alloy 6,5 K (typ.) 624 nm (typ.) Operating Temperature: to 4 C, Humidity: 2 to 85%RH (with no condensation) DC24V (max.) environment Metal connector: SRCN2A167P Storage environment Temperature: 2 to 6 C, Humidity: 2 to 85%RH (with no condensation) (Made by Japan Aviation Electronics Industry, Limited) 1, 2, 3: (+), 4, 5, 6: ( ), 7: NC Cooling method Natural air cooling Wave (nm) Be sure to read the "Instruction Guide" included with the product before use and observe cautionary information. Applicable Control Unit PSB3324 Direct number Model Applicable light No. of channels 2762 PSB3324 3W 1 P.27 Dimensions (mm) 1 HLND(1 n)t *n = Number from 1 to 27 (1 n): Emitting surface (1 n)+56.3: Full (2 n)m5 tap depth 5 Options Extension cable This cable connects the light and the Control Unit. You can choose from 2 m, 3 m, 5 m, 1 m, and 2 m. Direct number Model Cable Dimensions (mm) FCBn1.25SQME7 (n=2, 3, 5, 1) (1 n) FCB22.SQME7 2 Ø1.6 Ø1.6 Ø11.7 Ø Relative radiation strength (%) (Emitting surface) P1 (n1) 5 67 P1 (n1) 67 (n 2)+4M3 tap depth 5 29 Metal connector 7P FCB21.25SQME7 FCB31.25SQME7 FCB51.25SQME7 FCB11.25SQME7 FCB22.SQME7 2 m 3 m 5 m 1 m 2 m Information about Web Member registration If you register as a member on our website, you can download various materials, such as 3DCAD drawings and instruction guides. Also, we accept applications for lighting selections and free demo products from our contact page. Please feel free to use it. 22

24 Transmission type LTseries LT Series Direct Number Direct No Achieves both high uniformity and high brightness Provides optimal imaging with its unique illuminating mechanism LT6SW Supports highlyaccurate inspection in a highspeed environment We achieved both high uniformity and high brightness through our unique optical system. It can perform highlyaccurate inspections at a highspeed scan rate, and supports a wide range of uses. Graph of the distribution of brightness 1 distribution of the LT6SW (Long side) 1 (Short side) Illuminating mechanism optimal for onsite work Because the LT Series has mechanism where the sticks out from the main unit, it's possible to illuminate with the tip near the inspected item. This contributes to saving space in your inspection environment or equipment environment. Use for transmission By reducing the space between rolls, you can improve inspection speed. Relative brightness (%) Lateral position (mm) Lateral position (mm) uces slack Long side (6 mm) Short side (2.8 mm) Because we manufacture the product joining the LED panels, you can specify the of the in 1 mm increments. It can support various applications with its variety of sizes, from 1 mm to a maximum of 1,8 mm. LT1SW * Actual measurement values at 1% intensity in 1 mm illuminating distance. (Results may vary for individual units.) Emitting surface from a minimum of 1 mm, in increments of 1 mm Other lights Used in direct reflection Allows for inspections where the light is installed at a narrow angle with the camera. Compact structure LT Series Saves space Enables short distance illumination LT18SW You can specify the for the emitting surface up to a maximum of 1,8 mm Lighting characteristics The following radar chart introduces the LT Series' characteristics. Lighting characteristics radar chart Uniformity of the Illuminating mechanism By employing a mechanism where the sticks out from the main unit, it's possible to illuminate with the tip near the inspected item, even in a narrow space. Figure of LT's illuminating mechanism Using special radiating mechanism Camera Inspected object Low High Uniformity of the emitting surface This product LED 23 LT Series Direct Number Direct No You can easily access the product information page you want just by inputting the 7digit number in the direct number input space from CCS s website (Machine Vision Application page). The direct number is included on the Lineup of each product page.

25 Uniformity of the Applications This is particularly effective for highlyaccurate inspections which require noticing fine changes. Even for uniformity on the long side, we ensured high uniformity not just for the center of the short side but to both edges. You can use it for a wide variety of uses. Inspecting for cracks and damage in wafers Inspecting for fish eyes, scratches, and foreign materials on transparent film Inspecting the exterior of metal foil sheets Data Measured data for the LT3SW (Data listed here are actual measurement values. Results may vary for individual units.) Graph of the distribution of illuminance Graph of the distribution of brightness distribution distribution Relative illuminance (%) Lateral position (mm) Lateral position (mm) Relative brightness (%) * Actual measurement values at 1% intensity with an illuminating distance of 1 mm. * Actual measurement values at 1% intensity with an illuminating distance of 1 mm. (lx) Graph of the change in illuminance 3, 25, 2, 15, 1, 5, Change in illuminance Illuminating distance (mm) * Actual measurement values at 1% intensity at each illuminating distance. Radiation amount (%) Graph of output characteristics Output characteristics Intensity scales (Steps) * Actual measurement values when using analog Control Unit, PSB3324. Information about Web Member registration If you register as a member on our website, you can download various materials, such as 3DCAD drawings and instruction guides. Also, we accept applications for lighting selections and free demo products from our contact page. Please feel free to use it. 24

26 Transmission type LTseries LT Series Direct Number Direct No Lineup Direct number Model LED color Emitting surface Power consumption Applicable Control (max.) Weight (max.) Unit Dimensions LT1SW LT2SW LT3SW LT4SW LT5SW LT6SW LT7SW LT8SW LT9SW 1mm 2mm 3mm 4mm 5mm 6mm 7mm 8mm 9mm 15W 29W 43W 57W 71W 85W 99W 113W 128W 5g 1,g 1,5g 2,g 2,5g 3,g 3,5g 4,g 4,5g PSB LT1SW LT11SW LT12SW LT13SW LT14SW LT15SW LT16SW LT17SW LT18SW 1,mm 1,1mm 1,2mm 1,3mm 1,4mm 1,5mm 1,6mm 1,7mm 1,8mm 142W 156W 17W 184W 198W 212W 226W 24W 255W 5,g 5,5g 6,g 6,5g 7,g 7,5g 8,g 8,5g 9,g Common specifications LED color Correlated color temperature Input voltage Connector Polarity/signal (SW) 1, K (typ.) DC24V (max.) Metal connector: SRCN2A167P (Made by Japan Aviation Electronics Industry, Limited) 1, 2, 3: (+), 4, 5, 6: (), 7: NC Cable Case material Operating environment Storage environment Cooling method Aluminum alloy Temperature: to 4 C, Humidity: 2 to 85%RH (with no condensation) Temperature: 2 to 6 C, Humidity: 2 to 85%RH (with no condensation) Natural air cooling Light spectrum Wave (nm) Be sure to read the "Instruction Guide" included with the product before use and observe cautionary information. Dimensions (mm) 1 LT(1 n)sw *n = Number from 1 to () (1 n)+78: Full (Full )13 Detailed figure C 58 (27.6) (6) 24 (1 n): Emitting surface 24 (23.8) (12.4) 6 (83) (76) Relative radiation strength (%) Metal connector 7P (15) For installation 5M5 nut slot Detailed figure C 25 LT Series Direct Number Direct No You can easily access the product information page you want just by inputting the 7digit number in the direct number input space from CCS s website (Machine Vision Application page). The direct number is included on the Lineup of each product page.

27 Uniformity of the Applicable Control Unit PSB3324 Direct number Model Applicable light No. of channels 2762 PSB3324 3W 1 P.27 Options Extension cable This cable connects the light and the Control Unit. You can choose from 2 m, 3 m, 5 m, 1 m, and 2 m. Direct number Model FCB21.25SQME7 FCB31.25SQME7 FCB51.25SQME7 FCB11.25SQME7 FCB22.SQME7 Cable 2 m 3 m 5 m 1 m 2 m Dimensions (mm) FCBn1.25SQME7 (n=2, 3, 5, 1) FCB22.SQME7 (1 n) 2 Ø1.6 Ø1.6 Ø11.7 Ø1.6 Information about Web Member registration If you register as a member on our website, you can download various materials, such as 3DCAD drawings and instruction guides. Also, we accept applications for lighting selections and free demo products from our contact page. Please feel free to use it. 26

28 Analog Control Units PSB3324 series PSB3324 Direct Number Direct No. 219 Highly functional analog Control Unit that brings out the performance of line sensor lighting The PSB3324 analog Control Unit is a highly functional analog Control Unit equipped with three types of external control methods for a massive output capacity of 3 W. 245mm Can set intensity in 256 steps Equipped with an intensity range selection function 11mm Equipped with three types of external control functions (Parallel, EIA485, and Analog) PSB3324 Supports high output of 3 W Achieves a lightweight, compact design 97mm Weight 2,3g This single Unit is equipped with three types of control functions for parallel communication, EIA485 communication, and analog input Control mode Description ON/OFF input connector Parallel communication connector ID switch Set up to 4 Units EIA485 communication/ analog input connector Parallel communication EIA485 communication Analog input ON/OFF control Intensity control Control the intensity in 256 steps via parallel signal input Intensity control Command input for 256 steps of intensity via EIA485 communications ON/OFF control Command input via EIA485 communication Control the intensity in 256 steps via analog voltage Intensity control ( to 5 V) ON/OFF control is possible in combination with parallel, EIA485, or analog control LED Lights ON/OFF control via OFF signal input (parallel bit method) Digital display supports recreating intensity Optimize your intensity setting with the intensity range selection function Intensity range selector Output voltage 18 to 24 V 15 to 24 V 12 to 24 V Digital display Setting switch Quick operation using a pushbutton dial Intensity setting to 256 steps. Turn on the power while pressing the button to select external control mode. Press and hold for 2 seconds to lock the intensity value. Push to select. Press and hold to lock. Spin to adjust. You can choose an intensity range to match the lighting characteristics. * LED output varies depending on the lighting (Graph is for reference purposes). Output voltage (V) Intensity scales (Steps) Intensity range 12 to 24 V Intensity setting via analog input (V) Intensity range 18 to 24 V Intensity range 15 to 24 V 27 PSB3324 Direct Number Direct No. 219 You can easily access the product information page you want just by inputting the 7digit number in the direct number input space from CCS s website (Machine Vision Application page). The direct number is included on the Lineup of each product page.

29 ON/OFF PARALLEL INTENSITY PSB3324 MODE ANALOG/SERIAL EXTERNAL MANUAL RANGE 18 to 24 V 15 to 24 V 12 to 24 V ID Specifications Model PSB3324 Direct number 2762 Emitting method Constant emitting Drive method Constantvoltage system Intensity control method Variable voltage control No. of channels 1 channel Applicable light (rated) 24V 3W Manual and external Intensity control intensity Front manual/external switch (MODE) Variable output Select between 3 steps via the front intensity range selector (RANGE). voltage range Set any of 256 steps via the setting switch. Manual Press and hold the switch for 2 seconds to lock the intensity value. Parallel communication 8bit intensity value setting (B to B7) and write signal (WR) Serial communication Command input via EIA485 communication External Analog input Analog voltage ( V to 5 V) External control mode can be selected by pushing the setting switch while turning ON the power. Lighting control Parallel bit input Lighting signal (OFF) Serial communication Command input via EIA485 communication EIA485 ID Set via the front ID switch ( to 3). Maximum of 4 connected units. communication Terminating Set via the front ID switch settings resistance (terminating resistance is ON only when the ID is ). Emitting delay (typ.).1 s Error detection display "Err" is displayed on the frontpanel digital display. Error detection output Errors are output and light output is stopped for an internal AC/DC error. External control Error output terminal (OC, OE), photocoupler insulation, connector opencollector output, alarm open (load current of 1 ma or less), and error status (serial communication) Overcurrent protection Operates at 15% of the rated current or higher. Resets by cycling the Control Unit. Over voltage protection Operates at 12% to 155% of the rated voltage. Resets by cycling the Control Unit. Input voltage (rated) AC1 24V Power consumption (typ.) 41VA Frequency 5/6Hz 2 A/4 A (primary/secondary value at 1 VAC), Inrush current (typ.) 4 A/4 A (primary/secondary value at 24 VAC) * From a cold start Ground leakage current 3.5 ma max. (264 VAC, 6 Hz, with no load) Output voltage Select between 3 steps via the front intensity range selector. variation range (typ.) 12V to 24V * With no load 15V to 24V * With no load 18V to 24V * With no load Operating temperature and humidity Temperature: to 4 C, Humidity: 2 to 85%RH (with no condensation) Storage temperature and humidity Temperature: 2 to 6 C, Humidity: 2 to 85%RH (with no condensation) Acceleration: 19.6 m/sec2, frequency: 1 to 55 Hz, cycle: 3 min, Vibration resistance sweep cycle: each hour in the X, Y, and Z directions Cooling method Forced air cooling CE marking Safety standard: EN6111 compliant Conforms to EMC standard EN Class A Environmental regulation RoHS compliant Material, coating, surface processing Steel plate, Thickness of cover: 1., Thickness of chassis: 1.6, N3 leather tone finish Weight 2,3 g max. Accessories 3prong grounded AC cord (2 m): ( 1) Dimensions (mm) 11 Digital display 97 Setting switch (pushbutton dial) ID switch Analog input/eia485 communication connector Parallel communication connector ON/OFF input connector L13 L14 L11 L12 Front Options External control cables These are cables for parallel communication, EIA485 communication, and analog input. Select yours to match your control method. (mm) Parallel Communication Cable Direct number: 3683 Model: EXCB2M23 ON/OFF Input Cable Direct number: 3682 Model: EXCB2M13 Parallel Communication / ON/OFF Input Shared Cable Direct number: 3684 Model: EXCB2M1M pole MIL connector 2pole MIL connector Ø6.1 Only showing one end 1pole MIL connector Ø5 Only showing one end Analog Input Cable Direct number: 3687 Model: EXCB2E6AN3 3 EIA485 Communication Cable Direct number: 3686 Model: EXCB2E6SR3 3 EIA485 Communication Relay Cable Direct number: 3685 Model: EXCB2E33 * If connecting two or more Control Units, connect this cable to the external device side. 3 AMP Ø4.6 Only showing one end AMP Ø4.6 Only showing one end Ø3.9 Only showing one end EIA485 Communication Relay Cable Direct number: 3717 Model: EXCB2E6SRE33 * If connecting two or more Control Units, use this cable to connect the Control Unit and the relay connector. 3 EIA485 Communication Relay Cable Direct number: 3721 Model: EXCB2E3E3.2 * If connecting four Control Units, use this cable to connect relay connectors to one another. 2 EIA485 Communication Relay Connector Direct number: 372 Model: ECNRE3CN econ relay connector 3 pins x Rear Output connector (Metal connector) POWER AC inlet Manual/external mode selector Intensity range selector Fan exhaust outlets Control Unit switch Side 245 Fan exhaust outlets Fan air inlets Bottom 4M3 bottom mounting screw hole (Insertion depth of 5 mm) Be sure to read the "Instruction Guide" included with the product before use and observe cautionary information. Ø7.2 2pole MIL connector Only showing one end * This cable connects the Control Unit and an external device. (Between the Control Unit and external device) (Between the external device and relay connector) (Between the Control Unit and relay connector) Ø3.9 (Between relay connectors) Download a detailed procedure for connecting the EIA485 communication cable from the Web. Information about Web Member registration If you register as a member on our website, you can download various materials, such as 3DCAD drawings and instruction guides. Also, we accept applications for lighting selections and free demo products from our contact page. Please feel free to use it. 28

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in

Cross-beam scanning system to detect slim objects. 100 mm 3.937 in 891 Object Area Sensor General terms and conditions... F-17 Related Information Glossary of terms... P.1359~ Sensor selection guide...p.831~ General precautions... P.1405 PHOTO PHOTO Conforming to EMC

More information

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m 32.808 ft (Red LED)

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m 32.808 ft (Red LED) NX SERIES Compact Multi-voltage Photoelectric Power Supply Built-in Multi-voltage photoelectric sensor usable worldwide Conforming to ow Voltage and EMC Directive Multi-voltage The NX series can operate

More information

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications Compact size and high performance for the most challenging detection applications Compact dimensions (14x42x25 mm) Background suppression for transparent and shiny objects High speed contrast sensor up

More information

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles Clear Glass Sensor Optimum Sensor for Detecting Transparent Glass and Plastic Bottles E3S-CR67/62 Retroreflective Sensor smoothly detects 5-mm gaps. Detects transparent bottles that have a lens effect.

More information

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Automation System TROVIS 6400 TROVIS 6493 Compact Controller Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general

More information

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2 Cylindrical Sensor E2E/E2E2 A New Series of Easy-to-use and Tough E2E/E2E2 Models Long-size E2E2 Sensor Conforms to CENELEC Ideal for a variety of applications. With a metal connector that can be tightened

More information

Adjustment functions for both span and shift have been incorporated

Adjustment functions for both span and shift have been incorporated SENSORS FOR SERIES LED Type Wafer Alignment Sensor FX-0-F FT-F9 FD-F7 EX-F70/F60 M SH-7 FD-L4 M-DW The use of a safe LED light beam now allows for high precision detection with a resolution of 0!m (.8

More information

Guideline Laser Series

Guideline Laser Series Guideline Laser Series Highly visible alignment laser for visually demanding surfaces Red / Green long visible lines Equal brightness across length of the line Uniform Line (no fading at ends of the line)

More information

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors. 40-300 mm background suppression

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors. 40-300 mm background suppression Advanced line of miniature Asian style of photoelectric sensors 4-3 background suppression.7 m proximity, 15 with narrow beam 4 m polarized retroreflective 3 m LASER through beam Standard 3-wire output

More information

Sturdy aluminium housing, anodized in blue Female connector for optical fiber (please order optical fiber separately) Mounting holes

Sturdy aluminium housing, anodized in blue Female connector for optical fiber (please order optical fiber separately) Mounting holes SI-COLO Series SI-COLO2-LWL-HAMP-COL4 - Big measuring range: typ. 25 mm... 40 mm (with optical fiber and attachment optics KL-14 or KL-17) - Large assortment of optical fibers available (reflected or transmitted

More information

Power Supply and Indicator Unit Type 5024-1. Fig. 1 Type 5024-1. Mounting and Operating Instructions EB 9539 EN

Power Supply and Indicator Unit Type 5024-1. Fig. 1 Type 5024-1. Mounting and Operating Instructions EB 9539 EN Power Supply and Indicator Unit Type 5024-1 Fig. 1 Type 5024-1 Mounting and Operating Instructions EB 9539 EN Edition October 2003 Application 1 Application The Type 5024-1 Power Supply and Indicator Unit

More information

Laserlyte-Flex Alignment System

Laserlyte-Flex Alignment System Laserlyte-Flex Alignment System LaserLyte-Flex The LaserLyte-Flex Alignment System is a unique, interchangeable, low cost plug and play laser system. Designed specifically for aligning and positioning

More information

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color) Innovative indicators in a slim & stylish design. uces installation space. LH Series Surface Mount Indicators Key features of the LH series include: Direct mounting on surfaces such as panels, aluminum

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications Fiber Optic Sensors - S7 Advanced fiber optic amplifiers for high speed and low contrast applications DIN rail mountable models with dual digital displays speed models: 2 μs...5 ms Super high speed models:

More information

Appearance Type Setting distance Sensing area Model Remarks Camera with lighting. 34mm to 49mm 5mm x 4.9mm to 9mm x 8.

Appearance Type Setting distance Sensing area Model Remarks Camera with lighting. 34mm to 49mm 5mm x 4.9mm to 9mm x 8. ZFX-C/25-CD Easy Vision Touch, Connect & Go Easy vision intuitive teach & go user interfaces Live built-in LCD touch monitors for setup and iediate feedback Counication centralized setup & inspection via

More information

Basic Specifications. Electrical. EPSON Perfection 3170. Color EPSON MatrixCCD TM line sensor. device Effective pixels

Basic Specifications. Electrical. EPSON Perfection 3170. Color EPSON MatrixCCD TM line sensor. device Effective pixels Scanner Parts Document table Power cord Document cover Transparency unit (TPU) under lid Web Transparency unit (TPU) connector TPU indicator light e-mail Carriage and lamp (in the home position) USB port

More information

Series LC6D/LC6C. To power supply PLC. LC6C dedicated teaching box P.971. Options P.973

Series LC6D/LC6C. To power supply PLC. LC6C dedicated teaching box P.971. Options P.973 Series LCD To power supply Electric Actuator Series LCC Stepper Motor Driver LCD Series LX Dedicated Stepper Motor Driver and Positioning Driver Series LCD/LCC PLC Positioning unit (Not incl. To be provided

More information

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6 L-LAS Series L-LAS-LT-165-CL - Line laser 1 mw, laser class 2 - Visible laser line (red light 670 nm), typ. 2 mm x 3 mm - Reference distance approx. 165 mm - Measuring range typ. 65... 265 mm - Resolution

More information

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information. Wafer-carrier Mounting Photomicrosensors EE-SPY1/ CSM_EE-SPY1 DS_E_3_ Photomicrosensors for detecting wafer-carrier mounting. The mounting position is set with a pedestal. The contact surface with the

More information

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc Ultrasonic sensors for high precision detection of clear and transparent objects Clear object detection, inspection on transparent or highly reflective film and liquid level measurement Standard M18 tubular

More information

How To Use A Power Supply On A Powerline 2.2 (Ai)

How To Use A Power Supply On A Powerline 2.2 (Ai) KNX/EIB Product documentation Issue: 05.08.2010 629x1220 Push button sensor 3 comfort 1-gang Push button sensor 3 comfort 2-gang (1+1) Push button sensor 3 comfort 3-gang Push button sensor 3 comfort 4-gang

More information

HERZ-Thermal Actuators

HERZ-Thermal Actuators HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01

More information

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5 Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis

More information

Thru-Beam 80 to 320 mm 0.05 to 0.08 mm

Thru-Beam 80 to 320 mm 0.05 to 0.08 mm Series 7069A Fiber Optics The 7069A coupled with the appropriate cable forms a fiber optic sensor controller system capable of detecting objects as small as 0.01mm dia. and color marks on backgrounds of

More information

Appearance Type Setting distance Sensing area Model Remarks Camera with lighting. 34mm to 49mm 5mm x 4.9mm to 9mm x 8.

Appearance Type Setting distance Sensing area Model Remarks Camera with lighting. 34mm to 49mm 5mm x 4.9mm to 9mm x 8. ZFX-C10/15-CD Easy Vision Touch, Connect & Go Easy vision intuitive teach & go user interfaces Live built-in LCD touch monitors for setup and iediate feedback Counication centralized setup & inspection

More information

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply) transmitter (2 wire) / switch for continuous or On/Off Control Indication, monitoring, transmitting and continuous or On/Off control in one device Output signal 4...20 ma, 2-wire for continuous control

More information

Product and functional description

Product and functional description Product and functional description The KNX / DALI gateway N 141/02 is a 4 MU wide, DINrail mounted KNX device with one DALI interface to which up to 64 DALI actuators (e.g. DALI ballasts) can be connected

More information

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing Specifications and description HRTL 3B Laser diffuse reflection light scanner with background suppression Dimensioned drawing We reserve the right to make changes DS_HRTL3B_en.fm en 01-2010/12 50114049

More information

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x.16.6.1, 2CDG 110 1xx R0011

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x.16.6.1, 2CDG 110 1xx R0011 , 2CDG 110 1xx R0011 SA/S 8.16.6.1 2CDC 071 006 S0010 The 16/20 A Switch actuators are modular installation devices in Pro M Design for installation in the distribution board. The devices are especially

More information

2013 Wireless Video Intercom INSTALLATION GUIDE

2013 Wireless Video Intercom INSTALLATION GUIDE 2013 Wireless Video Intercom INSTALLATION GUIDE INDEX System configuration and wiring VL-SWD501 System Component.. 4 VL-SWD501EX wiring schematic diagram VL-SWD501EX wiring type and length... 5.... 6 Door

More information

14 PHOENIX CONTACT Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. info@powermation.com - 800-843-9859 - www.powermation.

14 PHOENIX CONTACT Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. info@powermation.com - 800-843-9859 - www.powermation. 14 PHOENIX CONTACT PLUSCON circular is a circular connector for use in industrial automation. The range of design sizes available is varied, starting with the design sizes M5 to M8 and M1, for sensor/actuator

More information

LM10. Micro Laser Displacement Sensor. The LM10 makes laser sensors super easy to use! New circuitry lowers costs

LM10. Micro Laser Displacement Sensor. The LM10 makes laser sensors super easy to use! New circuitry lowers costs 857 Micro Sensor General terms and conditions... P.1 Related Information Glossary of terms / General precautions... P.1019 / P.1027 Sensor selection guide... P.11~ / P.833~ About laser beam... P.1025 ~

More information

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks L-LAS-TB-CL serie laser light curtains for inline measuring tasks Maximum distance 2.000 mm Measurement range 6 up to 98 mm Resolution up to 4 µm up to 1,5 khz scan rate 0-10 V or 4-20 ma analogue output

More information

MCR1900 Media Converter 19-Slot Chassis

MCR1900 Media Converter 19-Slot Chassis MCR1900 Media Converter 19-Slot Chassis Installation Guide Part #5500304-11 Copyright Statement This document must not be reproduced in any way whatsoever, either printed or electronically, without the

More information

Connect to a remote PC via Ethernet with a monitor, keyboard, and mouse. This network monitor offers both long distance and wireless transmission.

Connect to a remote PC via Ethernet with a monitor, keyboard, and mouse. This network monitor offers both long distance and wireless transmission. 17" (43 cm) LCD Monitor Connect to a remote PC via Ethernet with a monitor, keyboard, and mouse. This network monitor offers both long distance and wireless transmission. Long Distance Transmission Easily

More information

TS93 EMR T/PT/TDE. Surface applied door closer

TS93 EMR T/PT/TDE. Surface applied door closer TS EMR T/PT/TDE Surface applied door closer Installation instructions: Pull side track mount door closer with smoke detector (EMR T) Push side track mount door closer with smoke detector (EMR PT) Double

More information

Description. Dimensions. Features. www.pwb-encoders.com. precision works better

Description. Dimensions. Features. www.pwb-encoders.com. precision works better Description The MEC22 is a high resolution optical hollow shaft encoder that can be fixed quickly and easily on different sizes of motor shafts. The encoder provides two square wave outputs in quadrature

More information

photoelectric highlights www.automation.datalogic.com

photoelectric highlights www.automation.datalogic.com photoelectric miniature sensors S8 series The new S8 series of compact sensors offers excellent detection performances, usually associated with sensors that have larger dimensions and a higher price. The

More information

Digital input modules

Digital input modules 8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,

More information

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.

More information

IntesisBox KNX Mitsubishi Heavy Industries AC

IntesisBox KNX Mitsubishi Heavy Industries AC IntesisBox KNX Mitsubishi Heavy Industries AC Gateway for integration of Mitsubishi Heavy Indsutries (MHI) Air Conditioners with KNX control systems. 1. Main Features Direct connection to KNX TP-1 (EIB)

More information

Smart Sensing Solutions Since 1954

Smart Sensing Solutions Since 1954 Smart Sensing Solutions Since 1954 X-tremely High Speed Photoelectric Registration Sensor 800-237-0946 ttco.com 813-886-4000 Photoelectric Registration Sensor The SMARTEYE X-MARK TM is the fastest, most

More information

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control Short Form Catalogue Alarm Systems Reliable Supervision and Control Alarm Monitors and Indicators The SELCO product range includes a number of alarm monitors and indicator panels for use in numerous applications.

More information

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.

More information

W150: Miniature photoelectric switch series with completely integrated electronics

W150: Miniature photoelectric switch series with completely integrated electronics Product group W50 Photoelectric proximity switch BGS Photoelectric proximity switch energ. Photoelectric reflex switch W50: iniature photoelectric switch series with completely integrated electronics Through-beam

More information

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624 PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624 v.1.0 AC/AC power supply unit Edition: 1 from 24 th October 2008 Supercedes edition: ---------- 10062009 CONTENTS: 1. Technical description. 1.1. General description

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically

More information

NUMERIC SIGN SP2-6XX / 180mm. Presentation

NUMERIC SIGN SP2-6XX / 180mm. Presentation NUMERIC SIGN SP2-6XX / 180mm Presentation 1 CONTENTS 1 CONTENTS... 2 2 PRESENTATION... 3 3 DIMENSIONS... 4 4 NUMERIC TYPES... 5 4.1 3 DIGITS, SP2-630/180 5 4.2 4 DIGITS, SP2-640/180 (PREFERRED TYPE) 5

More information

Series 6000 Torque measured metal bellow coupling

Series 6000 Torque measured metal bellow coupling Properties Free of float metal bellow coupling with integrated torque measurement Non-contact measurement system, high robustness High torsional stiffness Limited torque of inertia Performance Measurement

More information

Unidirectional Transmitter/ Receiver Units Introduction

Unidirectional Transmitter/ Receiver Units Introduction Unidirectional Transmitter/ Receiver Units Introduction Wireless Input/Output (I/O) connects directly to analog, discrete and pulse transducer signals. The signals are transmitted by radio and either re-created

More information

MANUAL PC1000R INFO@APART-AUDIO.COM

MANUAL PC1000R INFO@APART-AUDIO.COM MANUAL PC1000R INFO@APART-AUDIO.COM Features The APart PC1000R is a professional multisource CD/USB/SD card music player, equipped with balanced and unbalanced analog outputs, coaxial and optical digital

More information

CQM1-SF200/CS1W-SF200

CQM1-SF200/CS1W-SF200 Safety Relay Unit ( I/O Unit Type) CQM1-SF200/CS1W-SF200 CSM_CQM1-SF200_CS1W-SF200_DS_E_2_1 A Safety Relay Unit That Functions as a I/O Unit. Less Installation Space and Wiring Required. Safety Relay Unit

More information

Series 7500 Torque Sensor

Series 7500 Torque Sensor Properties PTO (Power Take-Off) shaft with integrated torque and angle measurement Non-contact measurement system, high robustness Plug & Play solution, no additional electronics required Performance Measurement

More information

Electric Rotary Actuator - On/Off or programmable control actuator

Electric Rotary Actuator - On/Off or programmable control actuator Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type

More information

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection Specifications and description Leuze electronic LS 78 Throughbeam photoelectric sensors Dimensioned drawing 180m 10-30 V DC! Voltage range from 12 30VDC with NPN, PNP and/or relay outputs! Light/dark switching!

More information

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils

More information

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG 110 084 R0011 , 2CDG 110 084 R0011 2CDC 071 112 F0008 The Fan Coil Actuator is a modular installation device (MDRC) in pro M design. It is intended for installation in the distribution board on 35 mm mounting rails.

More information

Introduction to Fiber Optic Cables. Photoelectric Sensors. 2Photoelectric Sensors, Standard Sensors, Fiber optic cables. Please Note!

Introduction to Fiber Optic Cables. Photoelectric Sensors. 2Photoelectric Sensors, Standard Sensors, Fiber optic cables. Please Note! Photoelectric, Standard, optic cables Photoelectric Introduction to Optic s Optic Diffuse and Thru-Beam Mode In applications involving small targets or unfavorable conditions, fiber optic cables may be

More information

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410 The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a

More information

PD 100A. Printing data system

PD 100A. Printing data system PD 100A Printing data system Operating instructions ENGLISH IMPORTANT: Read these instructions carefully before installing and using the device; do not forget following all additional information. Keep

More information

Inwall 4 Input / 4 Output Module

Inwall 4 Input / 4 Output Module Inwall 4 Input / 4 Output Module IO44C02KNX Product Handbook Product: Inwall 4 Input / 4 Output Module Order Code: IO44C02KNX 1/27 INDEX 1. General Introduction... 3 2. Technical data... 3 2.1 Wiring Diagram...

More information

ABB i-bus KNX SA/S Switch Actuators Product Manual

ABB i-bus KNX SA/S Switch Actuators Product Manual ABB i-bus KNX SA/S Switch Actuators Product Manual Contents Contents Page 1 General... 5 1.1 Using the product manual...5 1.1.1 Structure of the product manual...6 1.1.2 Notes...6 1.2 Product and functional

More information

OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL

OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL Phone: (209) 586-1022 (800) 545-1022 Fax: (209) 586-1026 OTOHP-NMS Rev. X1 E-Mail: salessupport@olsontech.com www.olsontech.com

More information

How To Read A Pipe From A Sensor

How To Read A Pipe From A Sensor Liquid Level Sensor Installation on pipes. Sensing by means electrostatic capacity and is not influenced by the color of the pipe or liquid. Available in 8 to mm dia. and to mm dia. models to enable sensing

More information

RRV934. Multi-controller. Synco living

RRV934. Multi-controller. Synco living s 2 709 Synco living Multi-controller RRV934 RF-based multi-controller For precontrol of up to 2 room groups For control of ventilation plant with up to 3 stages RF communication based on KNX standard

More information

Sensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector.

Sensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector. Photoelectric Sensor with Built-in Amplifier Photoelectric Sensor with built-in amplifier is applicable to a wide variety of lines and ensures a longer sensing distance than any other model. User-friendly

More information

Color Mark Sensor with Red or Green LED E3S-VS

Color Mark Sensor with Red or Green LED E3S-VS Color Mark Sensor with Red or Green LED Rugged IP67 Color Mark Sensor 1 ms response time Detects a wide variety of color marks PNP or NPN output ls Light-on/ Dark-on operation, wire selectable Vertical

More information

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

REGULINE 600VA / 1000VA REGULATOR USER MANUAL REGULINE 600VA / 1000VA REGULATOR USER MANUAL TUNÇMATİK REGULINE SERIES AUTOMATIC VOLTAGE REGULATOR Models: REGULINE 600VA / REGULINE 1000VA Principle of Operation Automatic Voltage Regulators regulate

More information

FCC COMPLIANCE STATEMENT FOR AMERICAN USERS

FCC COMPLIANCE STATEMENT FOR AMERICAN USERS FCC COMPLIANCE STATEMENT FOR AMERICAN USERS This equipment has been tested and found to comply with the limits for a CLASS A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical

More information

LED...A70..4-..Q Series Sealed High-Intensity

LED...A70..4-..Q Series Sealed High-Intensity LED...A70..4-..Q Series Sealed High-Intensity Area Lights High-Power Lighting for use with PresencePLUS and Other Vision Systems Features Rugged, waterproof housing, rated IEC IP68 Compact area light for

More information

RY2 miniature industrial relays

RY2 miniature industrial relays 6 RY2 Relays of general application For plug-in sockets, 35 mm rail mount acc. to PN-EN 60715 or on panel mounting Flat insert connectors - faston x 0,5 mm Recognitions, certifications, directives: RoHS,

More information

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models TML Series, 0 & 0 Watt Features C B Scheme LVD UL 090- Encapsulated power supplies with increased power density Replaces TML and TML 0 series PCB mount or chassis mount with screw terminals Single, dual

More information

sensors Miniature Sensors - S100 The universal miniature photoelectric sensor

sensors Miniature Sensors - S100 The universal miniature photoelectric sensor Miniature Sensors - S1 The universal miniature photoelectric sensor Two threaded front mounting holes Two slotted rear mounting holes Anti-tampering sensor (no adjustment) Standard optic functions and

More information

Inwall Room Temperature Unit

Inwall Room Temperature Unit Inwall Room Temperature Unit TM11B01KNX TM11B11KNX TM11B21KNX Product Handbook Product: Inwall Room Temperature Unit Order Code: TM11B01KNX TM11B11KNX TM11B21KNX Application Program ETS: TM11B_1KNX Inwall

More information

Mitel DECT Base Stations

Mitel DECT Base Stations Mitel DECT Base Stations On-site Mobility for Professionals The Mitel BS300 range of base stations offers a variety of coverage patterns to suit different situations. By choosing the right mix of base

More information

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series Programmable Terminal NPSeries Easy Setup with the Low-cost, Compact NP Series Simpler and More Versatile.OMRON s Compact NP Series Connect! Easier connection to OMRON PLCs and Temperature Controllers,

More information

Installation Instructions. Thermo Call TC3

Installation Instructions. Thermo Call TC3 Installation Instructions Thermo Call TC3 1 2 # 24990A 965 082 AMP 3 4 # 98393A # 67769A sw Improper installation or repair of Webasto heating and cooling systems can cause fire or the leakage of deadly

More information

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2... Magnetic and Hydraulic-Magnetic Circuit Breaker 840-G2... Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast

More information

TECHNICAL DATASHEET Incremental Encoder RI 58-O / RI 58-T

TECHNICAL DATASHEET Incremental Encoder RI 58-O / RI 58-T Universal industry standard encoder Up to 40 000 steps with 0 000 pulses High signal accuracy Protection class up to IP67 Flexible due to many flange and configuration variants Suitable for high shock

More information

Photovoltaic Solar Energy Unit EESFB

Photovoltaic Solar Energy Unit EESFB Technical Teaching Equipment Photovoltaic Solar Energy Unit EESFB Products Products range Units 5.-Energy Electronic console PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION Worlddidac Member ISO 9000: Quality

More information

Bar Code Reader Series BCL 20 A flexible reader for a variety of applications

Bar Code Reader Series BCL 20 A flexible reader for a variety of applications Bar Code Reader Series BCL 20 A flexible reader for a variety of applications PRODUCT INFORMATION The benchmark for flexibility. Laser scanners of the BCL 20 series as variable as your requirements demand.

More information

232982 KLQ750CO controller temp/intensity/feedback/24v/usb/rs622/analog trigger

232982 KLQ750CO controller temp/intensity/feedback/24v/usb/rs622/analog trigger RANGE OF PRODUCTS 233393 KLQ750LQ-N LED lightsource Ø4.25/3000K 233394 KLQ750LQ-N LED lightsource Ø4.25/7000K 233154 KLQ750LQ-N LED lightsource Ø4.25/8500K 233258 KLQ750LQ-F LED lightsource Ø4.25/8500K/feedback

More information

USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920

USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920 USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920 [This page intentionally left blank] Warning for Your Protection 1. Read these instructions. 2. Keep these

More information

PSDC 08128. PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

PSDC 08128. PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC. PSDC 08128 v.1.2 PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC. EN** Edition: 9 from 25.05.2015 Supersedes the edition: 8 from 12.12.2014 the 8x 1A/12V DC power output for powering

More information

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS) MILLENIUM Table of contents 1. INTRODUCTION 1 2. HARDWARE DESCRIPTION 2 3. INSTALLATION 5 4. CONNECTION 6 5. USER SAFETY AND PROTECTION OF EQUIPMENT 8 1. Introduction The MILLENIUM series has been designed

More information

EPSON Perfection 1650/1650 PHOTO. Scanner Parts. Scanner Specifications. Basic Specifications. device Effective pixels

EPSON Perfection 1650/1650 PHOTO. Scanner Parts. Scanner Specifications. Basic Specifications. device Effective pixels Scanner Parts Start and indicator light Photo Print USB port The has a transparency unit built into the scanner lid and holder for 35 mm film and slides: EPSON Perfection 1650 owners can purchase an optional

More information

LockerLock Schließgehäuse LockerLock lock case Boîtier de fermeture LockerLock Scatola di ciusura LockerLock Caja de cierre LockerLock

LockerLock Schließgehäuse LockerLock lock case Boîtier de fermeture LockerLock Scatola di ciusura LockerLock Caja de cierre LockerLock LockerLock Schließgehäuse LockerLock lock case Boîtier de fermeture LockerLock Scatola di ciusura LockerLock Caja de cierre LockerLock Caution! Õ It is necessary to read the section "Commissioning" in

More information

Miniature High-Resolution Registration Mark Sensor White LED AUTOSET Remote Setup Option

Miniature High-Resolution Registration Mark Sensor White LED AUTOSET Remote Setup Option REGISTRATION MARK SENSORS MARK EYE PRO 2 Miniature High-Resolution Registration Mark Sensor White LED AUTOSET Remote Setup Option Registration Mark Photoelectric Sensors 2-115 High-Resolution Registration

More information

APPLICATION NOTE. Basler racer Migration Guide. Mechanics. www.baslerweb.com. Flexible Mount Concept. Housing

APPLICATION NOTE. Basler racer Migration Guide. Mechanics. www.baslerweb.com. Flexible Mount Concept. Housing 62 62 APPLICATION NOTE www.baslerweb.com Basler racer Migration Guide This paper describes what to consider when replacing the Basler L100 Camera Link or the Basler runner Gigabit Ethernet (GigE) line

More information

COMPALARM AP GENERAL MAIN FEATURES

COMPALARM AP GENERAL MAIN FEATURES GENERAL The COMPALARM AP is a point alarm system, with as many normally closed input contacts. It givesthe possibility of selecting the alarm sequence according with 0 x 0 mm cells, fitted with ultra bright

More information

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS FRANCE Head office USA 4 Rue du Bois Chêne le loup Parc d Activité de Brabois 54 500 VANDOEUVRE LES NANCY (33) 0383442413, Fax (33) 0383443797

More information

Selector Switch Type 01

Selector Switch Type 01 Selector Switch Type 0 Compact positions selector switch,000 switching cycles with up to.0 Ncm switching torque Gold plated contacts: micron Robust metal housing with metal shaft Optional IP front panel

More information

GSM HOME SECURITY SYSTEM

GSM HOME SECURITY SYSTEM Cell /Mobile phone home security system GSM HOME SECURITY SYSTEM Model : GSM-120 TABLE OF CONTENTS 1. FEATURES... 1 2. APPLICATION... 2 3. SPECIFICATIONS... 3 4. FRONT PANEL & LAYOUT DESCRIPTION...6 5.

More information

Power Supplies 3. SDN-P DIN Rail Series

Power Supplies 3. SDN-P DIN Rail Series SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.

More information

NUMERIC SIGN SP2-6XX / 100mm. Presentation

NUMERIC SIGN SP2-6XX / 100mm. Presentation NUMERIC SIGN SP2-6XX / 100mm Presentation 1 CONTENTS 1 CONTENTS... 2 2 PRESENTATION... 3 2.1 STATES ENUMERATION 3 2.2 DIMENSIONS 4 3 NUMERIC TYPES... 5 3.1 3 DIGITS, SP2-630 5 3.2 4 DIGITS, SP2-640 5 3.3

More information

VOICE RECORDING SYSTEM ISDN PRI / BRI

VOICE RECORDING SYSTEM ISDN PRI / BRI Sense Box VOICE RECORDING SYSTEM ISDN PRI / BRI / Analog SUB-SYSTEM ISDN2, ISDN30 Sense Box USER MANUAL TABLE OF CONTENTS 1. STATUTORY INFORMATION... 3 1.1 SAFETY WARNING... 3 1.2 SAFETY EXTRA LOW VOLTAGE

More information

MOUNTING AND OPERATING INSTRUCTIONS

MOUNTING AND OPERATING INSTRUCTIONS MOUNTING AND OPERATING INSTRUCTIONS CF 51/55 1. Delivery CF 51/55-1 calculator with battery (optionally with mains power supply) - 1 wall mounting bracket - package with material for sealing, screws, wall

More information