RAID. Storage-centric computing, cloud computing. Benefits:
|
|
- Bennett Palmer
- 8 years ago
- Views:
Transcription
1 RAID Storage-centric computing, cloud computing. Benefits: Improved reliability (via error correcting code, redundancy). Improved performance (via redundancy).
2 Independent disks. RAID Level 0 Provides a striping configuration at the level of blocks (block striped). No redundancy (such as mirroring or parity bits). Requests to different disks can be handled in parallel. Single large request can be handled in parallel (improved performance but not reliability). - Bit-level striping - Byte-level striping - Block-level striping: most common
3 Independent disks. RAID Level 1 Redundancy (mirroring). Read can be from either disk. Write to both disks (can be done in parallel). Improved reliability (but not necessarily performance). High cost.
4 RAID Level 2 Synchronized spindles (r/w heads in same pos.). Parity bits for error-correcting code. P1 = x3 x5 x7 (parity=0 when # of 1 bits is even) P2 = x3 x6 x7 (parity=1 when # of 1 bits is odd) P4 = x5 x6 x7 Can correct 1-bit error C1 = P1 x3 x5 x7 if C1 = 1, there must be an error in one of the 4 bits: 1, 3, 5, and 7, which can be determined using a table. Hamming Code P1 P2 X3 P4 X5 X6 X7 - When a bit in data disks is damaged, the computed parity does not match the stored parity. - When a stored parity bit is damaged, then it does not match the computed parity.
5 1-bit error correction C1 = P1 x3 x5 x7 C2 = P2 x3 x6 x7 C4 = P4 x5 x6 x7 When C1C2C4 = 000, there is no disk errors. Otherwise, there is some disk error. Example: If X3X5X6X7 = 1010, then P1P2P4 = 101, hence C1C2C4 = 000. If we have the following: C1C2C4 = 110, then according to the table, it indicates that X3 is the disk that has the error (X3 appears in both C1 and C2). C C C P1 error P2 error X3 in error P4 error X5 in error X6 in error X7 in error If one of the disks fails, the remaining disks can be used to reconstruct the damaged data. It requires 3 disks overhead for 4 disks of data, whereas RAID 1 requires 4 disks overhead.
6 RAID Level 3 (bit-interleaved parity) Single parity disk is needed (P4). P4 is defined as follows: P4(i) = x3(i) x2(i) x1(i) x0(i) If x1 fails, then recovery can be carried out x1(i) = 0: if P4(i) = x3(i) x2(i) x0(i) x1(i) = 1: if P4(i) x3(i) x2(i) x0(i) Reduced mode: Read: missing data regenerated on the fly. Write: update parity disk (P4) for later regeneration.
7 RAID Level 3 (contd.) Since disk controllers can detect if a sector has been read correctly, so a single parity bit can be used for error correction and detection. RAID 3 is as good as RAID 2, but only with one parity disk overhead (RAID 2 is not used in practice). Advantages over RAID 1: Less overhead. - One parity disk is needed Transfer rate for R/W a single block is faster. N-way data striping (R/W of a byte are spread over multiple disks) Disadvantages over RAID 1: Fewer I/Os per second since every disk has to participate in every I/O request. Expense of computing and writing the parity.
8 RAID Level 4 (block-interleaved parity) Independent member disks Block level striping, and a parity block on parity disk for all N blocks on data disks. Higher overall I/O rate since all disks can be read in parallel.
9 RAID Level 4 (contd.) Implication of a write request P4 (i) = x3(i) x2(i) x1 (i) x0(i) = x3(i) x2(i) x1 (i) x0(i) x1(i) x1(i) = P4(i) x1(i) x1 (i) two reads (P4(i), x1(i)) and two writes (P4 (i), x1 (i)). Parity disk becomes potential bottleneck.
10 RAID Level 5 Independent member disks. Organized similarly as RAID 4. Parity strips are across all disks (parity for n th disk is stored in disk (n+1) mod 5) Avoid potential bottleneck in RAID 4.
11 Similar to RAID 5. Differences: RAID Level 6 2 bits of redundant data for every 4 bits of data Can tolerate 2 disks failures. P + Q redundancy scheme using Reed-Solomon Codes (two parity disks P and Q spreading in all disks
12 Nested RAID: RAID 0+1 RAID 0+1: disks are striped first, and then a stripe is mirrored to an equivalent stripe (two stripes). RAID striping sets: {D1,D3,D5,D7}, {D2,D4,D6,D8} Bottom-line: if 2 drives fail in different stripe sets, the entire system is down (both stripes down). stripe set D2 D4 D6 D8 D1 D3 D5 D7 D1 D2 D3 D4
13 Nested RAID: RAID 1+0 RAID 1+0: disks are mirrored in pairs first, and then the resulting mirrored pairs are striped (one stripe). stripe set D2 D4 D6 D8 D1 D2 D3 D4 RAID mirror sets: {D1,D2},, {D7,D8} Bottom-line: at most 4 drives can fail without affecting operation, so long as they are in diff. mirror sets. mirror set D1 D3 D5 D7
14 RAID Level 10 (RAID 1 + 0) It uses more disk space to provide redundant data than RAID 5. But, it offers a performance benefit through reading from all disks in parallel and avoiding the write penalty of RAID 5 (no parity). A second benefit is that it enjoys a better performance than RAID 5 when a failed drive remains unreplaced. In RAID 5, each attempted read of the failed drive can be fulfilled only by reading all of the other disks, whereas in RAID 10, a failed disk can be recovered by a single read of its mirrored pair. Because it has no parity blocks
15 Other Nested RAID RAID RAID 0+3/3+0 RAID 0+5 / 5+0 / 5+1 / 5+3 RAID 6+0
16 References overvie.html
How To Write A Disk Array
200 Chapter 7 (This observation is reinforced and elaborated in Exercises 7.5 and 7.6, and the reader is urged to work through them.) 7.2 RAID Disks are potential bottlenecks for system performance and
More informationChapter 6 External Memory. Dr. Mohamed H. Al-Meer
Chapter 6 External Memory Dr. Mohamed H. Al-Meer 6.1 Magnetic Disks Types of External Memory Magnetic Disks RAID Removable Optical CD ROM CD Recordable CD-R CD Re writable CD-RW DVD Magnetic Tape 2 Introduction
More informationNon-Redundant (RAID Level 0)
There are many types of RAID and some of the important ones are introduced below: Non-Redundant (RAID Level 0) A non-redundant disk array, or RAID level 0, has the lowest cost of any RAID organization
More informationOperating Systems. RAID Redundant Array of Independent Disks. Submitted by Ankur Niyogi 2003EE20367
Operating Systems RAID Redundant Array of Independent Disks Submitted by Ankur Niyogi 2003EE20367 YOUR DATA IS LOST@#!! Do we have backups of all our data???? - The stuff we cannot afford to lose?? How
More informationLecture 36: Chapter 6
Lecture 36: Chapter 6 Today s topic RAID 1 RAID Redundant Array of Inexpensive (Independent) Disks Use multiple smaller disks (c.f. one large disk) Parallelism improves performance Plus extra disk(s) for
More informationStoring Data: Disks and Files
Storing Data: Disks and Files (From Chapter 9 of textbook) Storing and Retrieving Data Database Management Systems need to: Store large volumes of data Store data reliably (so that data is not lost!) Retrieve
More informationReliability and Fault Tolerance in Storage
Reliability and Fault Tolerance in Storage Dalit Naor/ Dima Sotnikov IBM Haifa Research Storage Systems 1 Advanced Topics on Storage Systems - Spring 2014, Tel-Aviv University http://www.eng.tau.ac.il/semcom
More informationRAID. Contents. Definition and Use of the Different RAID Levels. The different RAID levels: Definition Cost / Efficiency Reliability Performance
RAID Definition and Use of the Different RAID Levels Contents The different RAID levels: Definition Cost / Efficiency Reliability Performance Further High Availability Aspects Performance Optimization
More informationPIONEER RESEARCH & DEVELOPMENT GROUP
SURVEY ON RAID Aishwarya Airen 1, Aarsh Pandit 2, Anshul Sogani 3 1,2,3 A.I.T.R, Indore. Abstract RAID stands for Redundant Array of Independent Disk that is a concept which provides an efficient way for
More informationCS420: Operating Systems
NK YORK COLLEGE OF PENNSYLVANIA HG OK 2 RAID YORK COLLEGE OF PENNSYLVAN James Moscola Department of Physical Sciences York College of Pennsylvania Based on Operating System Concepts, 9th Edition by Silberschatz,
More informationFault Tolerance & Reliability CDA 5140. Chapter 3 RAID & Sample Commercial FT Systems
Fault Tolerance & Reliability CDA 5140 Chapter 3 RAID & Sample Commercial FT Systems - basic concept in these, as with codes, is redundancy to allow system to continue operation even if some components
More informationRAID Performance Analysis
RAID Performance Analysis We have six 500 GB disks with 8 ms average seek time. They rotate at 7200 RPM and have a transfer rate of 20 MB/sec. The minimum unit of transfer to each disk is a 512 byte sector.
More informationDependable Systems. 9. Redundant arrays of. Prof. Dr. Miroslaw Malek. Wintersemester 2004/05 www.informatik.hu-berlin.de/rok/zs
Dependable Systems 9. Redundant arrays of inexpensive disks (RAID) Prof. Dr. Miroslaw Malek Wintersemester 2004/05 www.informatik.hu-berlin.de/rok/zs Redundant Arrays of Inexpensive Disks (RAID) RAID is
More informationWhy disk arrays? CPUs improving faster than disks
Why disk arrays? CPUs improving faster than disks - disks will increasingly be bottleneck New applications (audio/video) require big files (motivation for XFS) Disk arrays - make one logical disk out of
More informationData Storage - II: Efficient Usage & Errors
Data Storage - II: Efficient Usage & Errors Week 10, Spring 2005 Updated by M. Naci Akkøk, 27.02.2004, 03.03.2005 based upon slides by Pål Halvorsen, 12.3.2002. Contains slides from: Hector Garcia-Molina
More informationWhy disk arrays? CPUs speeds increase faster than disks. - Time won t really help workloads where disk in bottleneck
1/19 Why disk arrays? CPUs speeds increase faster than disks - Time won t really help workloads where disk in bottleneck Some applications (audio/video) require big files Disk arrays - make one logical
More informationES-1 Elettronica dei Sistemi 1 Computer Architecture
ES- Elettronica dei Sistemi Computer Architecture Lesson 7 Disk Arrays Network Attached Storage 4"» "» 8"» 525"» 35"» 25"» 8"» 3"» high bandwidth disk systems based on arrays of disks Decreasing Disk Diameters
More informationHow to choose the right RAID for your Dedicated Server
Overview of RAID Let's first address, "What is RAID and what does RAID stand for?" RAID, an acronym for "Redundant Array of Independent Disks, is a storage technology that links or combines multiple hard
More informationRAID Level Descriptions. RAID 0 (Striping)
RAID Level Descriptions RAID 0 (Striping) Offers low cost and maximum performance, but offers no fault tolerance; a single disk failure results in TOTAL data loss. Businesses use RAID 0 mainly for tasks
More informationAn Introduction to RAID. Giovanni Stracquadanio stracquadanio@dmi.unict.it www.dmi.unict.it/~stracquadanio
An Introduction to RAID Giovanni Stracquadanio stracquadanio@dmi.unict.it www.dmi.unict.it/~stracquadanio Outline A definition of RAID An ensemble of RAIDs JBOD RAID 0...5 Configuring and testing a Linux
More informationtechnology brief RAID Levels March 1997 Introduction Characteristics of RAID Levels
technology brief RAID Levels March 1997 Introduction RAID is an acronym for Redundant Array of Independent Disks (originally Redundant Array of Inexpensive Disks) coined in a 1987 University of California
More informationDisks and RAID. Profs. Bracy and Van Renesse. based on slides by Prof. Sirer
Disks and RAID Profs. Bracy and Van Renesse based on slides by Prof. Sirer 50 Years Old! 13th September 1956 The IBM RAMAC 350 Stored less than 5 MByte Reading from a Disk Must specify: cylinder # (distance
More informationFile System Design and Implementation
Transactions and Reliability Sarah Diesburg Operating Systems CS 3430 Motivation File systems have lots of metadata: Free blocks, directories, file headers, indirect blocks Metadata is heavily cached for
More informationDefinition of RAID Levels
RAID The basic idea of RAID (Redundant Array of Independent Disks) is to combine multiple inexpensive disk drives into an array of disk drives to obtain performance, capacity and reliability that exceeds
More informationStriped Set, Advantages and Disadvantages of Using RAID
Algorithms and Methods for Distributed Storage Networks 4: Volume Manager and RAID Institut für Informatik Wintersemester 2007/08 RAID Redundant Array of Independent Disks Patterson, Gibson, Katz, A Case
More informationDELL RAID PRIMER DELL PERC RAID CONTROLLERS. Joe H. Trickey III. Dell Storage RAID Product Marketing. John Seward. Dell Storage RAID Engineering
DELL RAID PRIMER DELL PERC RAID CONTROLLERS Joe H. Trickey III Dell Storage RAID Product Marketing John Seward Dell Storage RAID Engineering http://www.dell.com/content/topics/topic.aspx/global/products/pvaul/top
More informationPARALLEL I/O FOR HIGH PERFORMANCE COMPUTING
o. rof. Dr. eter Brezany arallele and Verteilte Datenbanksysteme 1 ARALLEL I/O FOR HIGH ERFORMANCE COMUTING Skriptum zur Vorlesung eter Brezany Institut für Scientific Computing Universität Wien E-Mail:
More informationHigh Performance Computing. Course Notes 2007-2008. High Performance Storage
High Performance Computing Course Notes 2007-2008 2008 High Performance Storage Storage devices Primary storage: register (1 CPU cycle, a few ns) Cache (10-200 cycles, 0.02-0.5us) Main memory Local main
More informationRAID Basics Training Guide
RAID Basics Training Guide Discover a Higher Level of Performance RAID matters. Rely on Intel RAID. Table of Contents 1. What is RAID? 2. RAID Levels RAID 0 RAID 1 RAID 5 RAID 6 RAID 10 RAID 0+1 RAID 1E
More informationRAID. Tiffany Yu-Han Chen. # The performance of different RAID levels # read/write/reliability (fault-tolerant)/overhead
RAID # The performance of different RAID levels # read/write/reliability (fault-tolerant)/overhead Tiffany Yu-Han Chen (These slides modified from Hao-Hua Chu National Taiwan University) RAID 0 - Striping
More informationRAID HARDWARE. On board SATA RAID controller. RAID drive caddy (hot swappable) SATA RAID controller card. Anne Watson 1
RAID HARDWARE On board SATA RAID controller SATA RAID controller card RAID drive caddy (hot swappable) Anne Watson 1 RAID The word redundant means an unnecessary repetition. The word array means a lineup.
More informationHow To Create A Multi Disk Raid
Click on the diagram to see RAID 0 in action RAID Level 0 requires a minimum of 2 drives to implement RAID 0 implements a striped disk array, the data is broken down into blocks and each block is written
More informationCHAPTER 4 RAID. Section Goals. Upon completion of this section you should be able to:
HPTER 4 RI s it was originally proposed, the acronym RI stood for Redundant rray of Inexpensive isks. However, it has since come to be known as Redundant rray of Independent isks. RI was originally described
More informationCS161: Operating Systems
CS161: Operating Systems Matt Welsh mdw@eecs.harvard.edu Lecture 18: RAID April 19, 2007 2007 Matt Welsh Harvard University 1 RAID Redundant Arrays of Inexpensive Disks Invented in 1986-1987 by David Patterson
More informationHow To Improve Performance On A Single Chip Computer
: Redundant Arrays of Inexpensive Disks this discussion is based on the paper:» A Case for Redundant Arrays of Inexpensive Disks (),» David A Patterson, Garth Gibson, and Randy H Katz,» In Proceedings
More informationRAID Made Easy By Jon L. Jacobi, PCWorld
9916 Brooklet Drive Houston, Texas 77099 Phone 832-327-0316 www.safinatechnolgies.com RAID Made Easy By Jon L. Jacobi, PCWorld What is RAID, why do you need it, and what are all those mode numbers that
More informationComprehending the Tradeoffs between Deploying Oracle Database on RAID 5 and RAID 10 Storage Configurations. Database Solutions Engineering
Comprehending the Tradeoffs between Deploying Oracle Database on RAID 5 and RAID 10 Storage Configurations A Dell Technical White Paper Database Solutions Engineering By Sudhansu Sekhar and Raghunatha
More informationInput / Ouput devices. I/O Chapter 8. Goals & Constraints. Measures of Performance. Anatomy of a Disk Drive. Introduction - 8.1
Introduction - 8.1 I/O Chapter 8 Disk Storage and Dependability 8.2 Buses and other connectors 8.4 I/O performance measures 8.6 Input / Ouput devices keyboard, mouse, printer, game controllers, hard drive,
More informationRAID Overview 91.520
RAID Overview 91.520 1 The Motivation for RAID Computing speeds double every 3 years Disk speeds can t keep up Data needs higher MTBF than any component in system IO Performance and Availability Issues!
More informationRAID technology and IBM TotalStorage NAS products
IBM TotalStorage Network Attached Storage October 2001 RAID technology and IBM TotalStorage NAS products By Janet Anglin and Chris Durham Storage Networking Architecture, SSG Page No.1 Contents 2 RAID
More informationRAID Technology. RAID Overview
Technology In the 1980s, hard-disk drive capacities were limited and large drives commanded a premium price. As an alternative to costly, high-capacity individual drives, storage system developers began
More informationHARD DRIVE CHARACTERISTICS REFRESHER
The read/write head of a hard drive only detects changes in the magnetic polarity of the material passing beneath it, not the direction of the polarity. Writes are performed by sending current either one
More informationChapter 6. 6.1 Introduction. Storage and Other I/O Topics. p. 570( 頁 585) Fig. 6.1. I/O devices can be characterized by. I/O bus connections
Chapter 6 Storage and Other I/O Topics 6.1 Introduction I/O devices can be characterized by Behavior: input, output, storage Partner: human or machine Data rate: bytes/sec, transfers/sec I/O bus connections
More informationModule 6. RAID and Expansion Devices
Module 6 RAID and Expansion Devices Objectives 1. PC Hardware A.1.5 Compare and contrast RAID types B.1.8 Compare expansion devices 2 RAID 3 RAID 1. Redundant Array of Independent (or Inexpensive) Disks
More informationRAID Overview: Identifying What RAID Levels Best Meet Customer Needs. Diamond Series RAID Storage Array
ATTO Technology, Inc. Corporate Headquarters 155 Crosspoint Parkway Amherst, NY 14068 Phone: 716-691-1999 Fax: 716-691-9353 www.attotech.com sales@attotech.com RAID Overview: Identifying What RAID Levels
More informationIBM ^ xseries ServeRAID Technology
IBM ^ xseries ServeRAID Technology Reliability through RAID technology Executive Summary: t long ago, business-critical computing on industry-standard platforms was unheard of. Proprietary systems were
More informationRAID Storage System of Standalone NVR
ACTi Knowledge Base Category: Installation & Configuration Note Sub-category: Hardware; Recording & Storage Model: XNR-4200, GNR-2000 Firmware: Software: Author: Ando.Meritee Published: 2011/05/04 Reviewed:
More informationIntroduction Disks RAID Tertiary storage. Mass Storage. CMSC 412, University of Maryland. Guest lecturer: David Hovemeyer.
Guest lecturer: David Hovemeyer November 15, 2004 The memory hierarchy Red = Level Access time Capacity Features Registers nanoseconds 100s of bytes fixed Cache nanoseconds 1-2 MB fixed RAM nanoseconds
More informationPhysical Data Organization
Physical Data Organization Database design using logical model of the database - appropriate level for users to focus on - user independence from implementation details Performance - other major factor
More informationLecture 23: Multiprocessors
Lecture 23: Multiprocessors Today s topics: RAID Multiprocessor taxonomy Snooping-based cache coherence protocol 1 RAID 0 and RAID 1 RAID 0 has no additional redundancy (misnomer) it uses an array of disks
More informationDisk Array Data Organizations and RAID
Guest Lecture for 15-440 Disk Array Data Organizations and RAID October 2010, Greg Ganger 1 Plan for today Why have multiple disks? Storage capacity, performance capacity, reliability Load distribution
More informationRAID. RAID 0 No redundancy ( AID?) Just stripe data over multiple disks But it does improve performance. Chapter 6 Storage and Other I/O Topics 29
RAID Redundant Array of Inexpensive (Independent) Disks Use multiple smaller disks (c.f. one large disk) Parallelism improves performance Plus extra disk(s) for redundant data storage Provides fault tolerant
More informationFiling Systems. Filing Systems
Filing Systems At the outset we identified long-term storage as desirable characteristic of an OS. EG: On-line storage for an MIS. Convenience of not having to re-write programs. Sharing of data in an
More informationISTANBUL AYDIN UNIVERSITY
ISTANBUL AYDIN UNIVERSITY 2013-2014 Academic Year Fall Semester Department of Software Engineering SEN361 COMPUTER ORGANIZATION HOMEWORK REPORT STUDENT S NAME : GÖKHAN TAYMAZ STUDENT S NUMBER : B1105.090068
More informationDisk Storage & Dependability
Disk Storage & Dependability Computer Organization Architectures for Embedded Computing Wednesday 19 November 14 Many slides adapted from: Computer Organization and Design, Patterson & Hennessy 4th Edition,
More informationCOSC 6374 Parallel Computation. Parallel I/O (I) I/O basics. Concept of a clusters
COSC 6374 Parallel I/O (I) I/O basics Fall 2012 Concept of a clusters Processor 1 local disks Compute node message passing network administrative network Memory Processor 2 Network card 1 Network card
More informationDatabase Management Systems
4411 Database Management Systems Acknowledgements and copyrights: these slides are a result of combination of notes and slides with contributions from: Michael Kiffer, Arthur Bernstein, Philip Lewis, Anestis
More informationChapter 13. Disk Storage, Basic File Structures, and Hashing
Chapter 13 Disk Storage, Basic File Structures, and Hashing Chapter Outline Disk Storage Devices Files of Records Operations on Files Unordered Files Ordered Files Hashed Files Dynamic and Extendible Hashing
More informationVERY IMPORTANT NOTE! - RAID
Disk drives are an integral part of any computing system. Disk drives are usually where the operating system and all of an enterprise or individual s data are stored. They are also one of the weakest links
More informationRAID: Redundant Arrays of Independent Disks
RAID: Redundant Arrays of Independent Disks Dependable Systems Dr.-Ing. Jan Richling Kommunikations- und Betriebssysteme TU Berlin Winter 2012/2013 RAID: Introduction Redundant array of inexpensive disks
More informationCalifornia Software Labs
WHITE PAPERS FEBRUARY 2006 California Software Labs CSWL INC R e a l i z e Y o u r I d e a s Redundant Array of Inexpensive Disks (RAID) Redundant Array of Inexpensive Disks (RAID) aids development of
More informationW4118: RAID. Instructor: Junfeng Yang
W4118: RAID Instructor: Junfeng Yang References: Modern Operating Systems (3 rd edition), Operating Systems Concepts (8 th edition), previous W4118, and OS at MIT, Stanford, and UWisc RAID motivation Performance
More informationSummer Student Project Report
Summer Student Project Report Dimitris Kalimeris National and Kapodistrian University of Athens June September 2014 Abstract This report will outline two projects that were done as part of a three months
More informationHard Disk Drives and RAID
Hard Disk Drives and RAID Janaka Harambearachchi (Engineer/Systems Development) INTERFACES FOR HDD A computer interfaces is what allows a computer to send and retrieve information for storage devices such
More informationCopyright 2007 Ramez Elmasri and Shamkant B. Navathe. Slide 13-1
Slide 13-1 Chapter 13 Disk Storage, Basic File Structures, and Hashing Chapter Outline Disk Storage Devices Files of Records Operations on Files Unordered Files Ordered Files Hashed Files Dynamic and Extendible
More informationDistributed Storage Networks and Computer Forensics
Distributed Storage Networks 5 Raid-6 Encoding Technical Faculty Winter Semester 2011/12 RAID Redundant Array of Independent Disks Patterson, Gibson, Katz, A Case for Redundant Array of Inexpensive Disks,
More informationRAID Levels and Components Explained Page 1 of 23
RAID Levels and Components Explained Page 1 of 23 What's RAID? The purpose of this document is to explain the many forms or RAID systems, and why they are useful, and their disadvantages. RAID - Redundant
More informationAlgorithms and Methods for Distributed Storage Networks 5 Raid-6 Encoding Christian Schindelhauer
Algorithms and Methods for Distributed Storage Networks 5 Raid-6 Encoding Institut für Informatik Wintersemester 2007/08 RAID Redundant Array of Independent Disks Patterson, Gibson, Katz, A Case for Redundant
More informationStoring Data: Disks and Files. Disks and Files. Why Not Store Everything in Main Memory? Chapter 7
Storing : Disks and Files Chapter 7 Yea, from the table of my memory I ll wipe away all trivial fond records. -- Shakespeare, Hamlet base Management Systems 3ed, R. Ramakrishnan and J. Gehrke 1 Disks and
More informationRAID Implementation for StorSimple Storage Management Appliance
RAID Implementation for StorSimple Storage Management Appliance Alpa Kohli June, 2012 KB-00008 Document Revision 1 StorSimple knowledge base articles are intended to provide customers with the information
More informationPrice/performance Modern Memory Hierarchy
Lecture 21: Storage Administration Take QUIZ 15 over P&H 6.1-4, 6.8-9 before 11:59pm today Project: Cache Simulator, Due April 29, 2010 NEW OFFICE HOUR TIME: Tuesday 1-2, McKinley Last Time Exam discussion
More informationStandard RAID levels - Wikipedia, the free encycl...
Standard RAID levels From Wikipedia, the free encyclopedia Wikipedia is sustained by people like you. Please donate today. The st andard RAID levels are a basic set of RAID configurations and employ striping,
More informationStorage node capacity in RAID0 is equal to the sum total capacity of all disks in the storage node.
RAID configurations defined 1/7 Storage Configuration: Disk RAID and Disk Management > RAID configurations defined Next RAID configurations defined The RAID configuration you choose depends upon how you
More informationStorage and File Structure
Storage and File Structure Chapter 10: Storage and File Structure Overview of Physical Storage Media Magnetic Disks RAID Tertiary Storage Storage Access File Organization Organization of Records in Files
More informationChapter 9: Peripheral Devices: Magnetic Disks
Chapter 9: Peripheral Devices: Magnetic Disks Basic Disk Operation Performance Parameters and History of Improvement Example disks RAID (Redundant Arrays of Inexpensive Disks) Improving Reliability Improving
More informationStorage. The text highlighted in green in these slides contain external hyperlinks. 1 / 14
Storage Compared to the performance parameters of the other components we have been studying, storage systems are much slower devices. Typical access times to rotating disk storage devices are in the millisecond
More informationHP Smart Array Controllers and basic RAID performance factors
Technical white paper HP Smart Array Controllers and basic RAID performance factors Technology brief Table of contents Abstract 2 Benefits of drive arrays 2 Factors that affect performance 2 HP Smart Array
More informationChapter 13 Disk Storage, Basic File Structures, and Hashing.
Chapter 13 Disk Storage, Basic File Structures, and Hashing. Copyright 2004 Pearson Education, Inc. Chapter Outline Disk Storage Devices Files of Records Operations on Files Unordered Files Ordered Files
More informationGuide to SATA Hard Disks Installation and RAID Configuration
Guide to SATA Hard Disks Installation and RAID Configuration 1. Guide to SATA Hard Disks Installation...2 1.1 Serial ATA (SATA) Hard Disks Installation...2 2. Guide to RAID Configurations...3 2.1 Introduction
More informationCRI RAID. Robert A. Albers, Jr., Cray Research, Inc., Eagan, Minnesota 1 INTRODUCTION 4 HARDWARE RAID 2 RAID LEVELS 3 SOFTWARE RAID
CRI RAID Robert A. Albers, Jr., Cray Research, Inc., Eagan, Minnesota ABSTRACT: Cray Research has several RAID offerings. This includes RAID implemented at both the software and hardware levels. As part
More informationSistemas Operativos: Input/Output Disks
Sistemas Operativos: Input/Output Disks Pedro F. Souto (pfs@fe.up.pt) April 28, 2012 Topics Magnetic Disks RAID Solid State Disks Topics Magnetic Disks RAID Solid State Disks Magnetic Disk Construction
More informationUsing RAID6 for Advanced Data Protection
Using RAI6 for Advanced ata Protection 2006 Infortrend Corporation. All rights reserved. Table of Contents The Challenge of Fault Tolerance... 3 A Compelling Technology: RAI6... 3 Parity... 4 Why Use RAI6...
More informationOceanStor 9000 InfoProtector Technical White Paper. Issue 01. Date 2014-02-13 HUAWEI TECHNOLOGIES CO., LTD.
OceanStor 9000 InfoProtector Technical White Paper Issue 01 Date 2014-02-13 HUAWEI TECHNOLOGIES CO., LTD. Copyright Huawei Technologies Co., Ltd. 2014. All rights reserved. No part of this document may
More informationToday s Papers. RAID Basics (Two optional papers) Array Reliability. EECS 262a Advanced Topics in Computer Systems Lecture 4
EECS 262a Advanced Topics in Computer Systems Lecture 4 Filesystems (Con t) September 15 th, 2014 John Kubiatowicz Electrical Engineering and Computer Sciences University of California, Berkeley Today
More informationCS 61C: Great Ideas in Computer Architecture. Dependability: Parity, RAID, ECC
CS 61C: Great Ideas in Computer Architecture Dependability: Parity, RAID, ECC Instructor: Justin Hsia 8/08/2013 Summer 2013 Lecture #27 1 Review of Last Lecture MapReduce Data Level Parallelism Framework
More informationStorage Technologies - 2
Antoniu Pop 1 The University of Manchester COMP 25212 Storage Technologies - 2 Antoniu Pop antoniu.pop@manchester.ac.uk 16 April 2015 Antoniu Pop 2 The University of Manchester COMP 25212 Storage Technologies
More informationIntroduction. What is RAID? The Array and RAID Controller Concept. Click here to print this article. Re-Printed From SLCentral
Click here to print this article. Re-Printed From SLCentral RAID: An In-Depth Guide To RAID Technology Author: Tom Solinap Date Posted: January 24th, 2001 URL: http://www.slcentral.com/articles/01/1/raid
More information1 Storage Devices Summary
Chapter 1 Storage Devices Summary Dependability is vital Suitable measures Latency how long to the first bit arrives Bandwidth/throughput how fast does stuff come through after the latency period Obvious
More informationNutanix Tech Note. Failure Analysis. 2013 All Rights Reserved, Nutanix Corporation
Nutanix Tech Note Failure Analysis A Failure Analysis of Storage System Architectures Nutanix Scale-out v. Legacy Designs Types of data to be protected Any examination of storage system failure scenarios
More informationNAS 251 Introduction to RAID
NAS 251 Introduction to RAID Set up a storage volume with RAID A S U S T O R C O L L E G E COURSE OBJECTIVES Upon completion of this course you should be able to: 1. Have a basic understanding of RAID
More informationTheoretical Aspects of Storage Systems Autumn 2009
Theoretical Aspects of Storage Systems Autumn 2009 Chapter 1: RAID André Brinkmann University of Paderborn Personnel Students: ~13.500 students Professors: ~230 Other staff: ~600 scientific, ~630 non-scientific
More informationBest Practices RAID Implementations for Snap Servers and JBOD Expansion
STORAGE SOLUTIONS WHITE PAPER Best Practices RAID Implementations for Snap Servers and JBOD Expansion Contents Introduction...1 Planning for the End Result...1 Availability Considerations...1 Drive Reliability...2
More informationAn Introduction to RAID 6 ULTAMUS TM RAID
An Introduction to RAID 6 ULTAMUS TM RAID The highly attractive cost per GB of SATA storage capacity is causing RAID products based on the technology to grow in popularity. SATA RAID is now being used
More informationChapter 13. Chapter Outline. Disk Storage, Basic File Structures, and Hashing
Chapter 13 Disk Storage, Basic File Structures, and Hashing Copyright 2007 Ramez Elmasri and Shamkant B. Navathe Chapter Outline Disk Storage Devices Files of Records Operations on Files Unordered Files
More informationAssessing. To meet an overall reliability objective, the individual components. the Reliability of RAID Systems
Assessing the Reliability of RAID Systems By Abraham Long, Jr. To determine the overall reliability of a RAID-based storage system, it is important to accurately assess the reliability of the RAID subsystem.
More informationChapter 11 I/O Management and Disk Scheduling
Operating Systems: Internals and Design Principles, 6/E William Stallings Chapter 11 I/O Management and Disk Scheduling Dave Bremer Otago Polytechnic, NZ 2008, Prentice Hall I/O Devices Roadmap Organization
More informationSSDs and RAID: What s the right strategy. Paul Goodwin VP Product Development Avant Technology
SSDs and RAID: What s the right strategy Paul Goodwin VP Product Development Avant Technology SSDs and RAID: What s the right strategy Flash Overview SSD Overview RAID overview Thoughts about Raid Strategies
More informationTechnical White paper RAID Protection and Drive Failure Fast Recovery
Technical White paper RAID Protection and Drive Failure Fast Recovery RAID protection is a key part of all ETERNUS Storage Array products. Choices of the level chosen to meet customer application requirements
More informationHigh-Performance SSD-Based RAID Storage. Madhukar Gunjan Chakhaiyar Product Test Architect
High-Performance SSD-Based RAID Storage Madhukar Gunjan Chakhaiyar Product Test Architect 1 Agenda HDD based RAID Performance-HDD based RAID Storage Dynamics driving to SSD based RAID Storage Evolution
More information