How to define flow cytometry? Flow cytometry. Historic. Flow cytometry principle. Flow cytometers: analysis and cell sorting Influx Becton Dickinson

Size: px
Start display at page:

Download "How to define flow cytometry? Flow cytometry. Historic. Flow cytometry principle. Flow cytometers: analysis and cell sorting Influx Becton Dickinson"

Transcription

1 How to define flow cytometry? Méthodes d étude de la cellule MV426 Flow cytometry The possibility to measure individually and simultaneously several physical and biological characteristics of a cell in a heterogeneous solution. It allows the identification of subpopulations and the estimation of an average population To measure (-metry) optical cells properties (cyto-) through a fluid (flow) in front of an excitatory laser beam High rate (5.1 4 cells/s) and high sensitivity (1 antigenic factors/cell) The possibility of separating physically every cell analysed Historic 1934 Moldavan - Cellular numeration : capillary + photoelectrique captor 1949 Coulter - Count, size (conductance variability) 1953 Crosland -Taylor - Use laminar flow as describes by Reynolds in 1883 CyFlow Cube - Partec LSR Fortessa Becton Dickinson 1965 Kamentsky - Analysis of cells constituents (2 parameters : DNA + Proteins) Fulwyler - Cell sorting using electrostatic methods 1969 Van Dilla - Laser excitation Some examples of Gallios Beckman Coulter Flow cytometers : analysis 1972 Herzenberg - Cells sorting (1st article et 1st cytometers commercialization) 1978 Schlossman - Monoclonal antibodies production Reinhertz - New fluorochromes development 24 Perfetto - Analyze of 19 parameters (17 fluorescent signals) 26 Chattopadhyay - Immunophenotypage by quantum Dots MACSQuant MiltenyiBiotec EasyCyte8HT Guava Technologies C6 Accuri MoFlo XDP Beckman Coulter Flow cytometry principle Astrios Beckman Coulter Some examples of Flow cytometers: analysis and cell sorting Influx Becton Dickinson 1) Fluidic system Presents Particles in front of the laser beam 3) Electronic system Allows the conversion from the different luminous signals to electronic signals which can be stored and processed by the computer via an appropriate software FACSAria Becton Dickinson FACSJazz Becton Dickinson Invitrogen 2) Optical system Composed of one (or more) monochromatic excitation source(s) (LASER), optical filters and mirrors which select and separate emission wavelength towards the appropriate detectors

2 Sample under pressure Cells suspension sheath fluid under pressure Carry away Flow Cell Nozzel Cell flow Light excitation (laser(s), lamp) Fluidic system Carry vein hydrofocalization Separation Alignment Laminar flow Sheath fluid flow induces a fast and regular acceleration to cells and forces them to be aligned in order to be analyzed one by one Light excitation Psa low Psa Ps Weak pressure difference Slow speed of passage Important focalization of cells Tiny distribution Sample pressure Sample under pressure Cells suspension sheath fluid under pressure Flow cell Light excitation Psa high Psa Ps Important pressure difference Fast speed of passage Weak focalization of cells Large distribution Psa = pression sample Ps = pression sheath The cytometer records the behaviour of the cell trough the laser beam, by measuring : Optical system Light scattering (informs on the morphology and cell structure) Detection at 9 granularity: SSC or SS or 9LS Optical system Fluorescence emission («Fluorescence Light» (FL)) Spontaneous (autofluorescence) Associated to free or bound fluorochromes Fluorescence are emitted in all directions and are always in another color than the excitation laser Light excitation Detection at small angles size : FSC or FS or FALS Invitrogen Invitrogen Color depends of the fluorescent probe nature Invitrogen - Light scattering at small angles (Forward Scattered Light, FSC) represents the light incidence angles from the LASER and is directly proportional to the particle size and area (relative measure of size) - Light scattering at large angles (Side Scattered Light, SSC) measures the reflected light and depends on granularity and complexity of the particle (relative measure of granularity) Induced fluorescence from different fluorochromes is separated by an optical filters plot. The selection filters depends on the Excitation and emission wavelengths Optical system Optical filter Filters and dichroic mirrors are part of optic elements. They realize the separation of channels and select wavelength Optical filters are materials which absorb specific wavelength and transmit others Incidence ray Transmitted light Absorbe light FSC signals are received by a photodiode. SSC signals and fluorescents emissions are collected and diverted to photomultipliers tubes (PMT). Each PMT have an optic filter which allow to detect specific wavelength When filter and incidence light make a 45 angle the not absorbed wavelengths are reflected Dichroic mirrors Reflected light Incidence ray Transmitted light Each fluorochrome is detected in a unique fluorescence optic channel: emitted light follows a specific path from the interrogation point to the detector Reflection Transmission Absorption 45

3 Volt Volt Height (H) % of transmission % de transmission % de transmission SP5 LP5 5/5 % of transmission % de transmission % de transmission Optical filter Optical filter Different filters types used in CMF Different filters types used in CMF l >5 Short Pass filter Long pass filter Band Pass filter l >525 Short Pass filter Long pass filter Band Pass filter l < l > l <5 l <475 Transitions between absorption and transmission are not perfect SP filter LP filter BP filter example SP 52 LP 52 BP 5 BP 5/ wavelength l wavelength l wavelength l wavelength l wavelength l wavelength l Optical filter Optical system Different filter types used in CMF Band Pass 525/ BP 525/ nm Ex : Optical bench Ligth sources Light source Dichroïc Long Pass wavelength l BD LSR cell analyzers Invitrogen Light source wavelength l BC Gallios BC MoFlo XDP A. Munier-1/212 Photons detectors In order to measure the optical signals they have to be converted in electric signals (volts). The choice of the detector depends on the photon number Diodes 1v 1e- Optical system Detect intense signals (ex : size parameter) Impulse formation Flow Laser Electronic system The electrical signals created by light emission are called impulsions. Their amplitude values lies between and 1 volts 1 Area (A) Laser Photomultipliers Tubes (PMT) 1v ne- High sensitivity (ex : structural and fluorescent parameters detector) used for weak signals Laser Width (W) Time (µ Seconds) Time

4 SSC SSC Cells number Cells number Cells number Electronic system Electronic system electrical impulsion (volt) has to be transformed into numerical data by a digital analogical converter (ADC) Intensity (volts) arbitrary units Convert into binary signal by the ADC, signals are processed individually Cells Light excitation 1 Conversion 124 ex : An ADC of 1 bits (2 1 ) enables 124 values Flow Photomultiplier Amplification Each mesurement from each detector is called to as a parameter Time Linear or Logarithmic scale etc Arbitrary units Relative light intensity Data acquisition The cytometer stores all parameters of every cell : List mode (LMD) Histogram Data representation Two parameters histogram Cells analysis FSC SSC FL1 FL2 FL3 Time (µsec) 1 rst de rd th Last Advantage : everything could be recalculated - + Relative light intensity Three-dimensional plot Other two parameters representations 842 UL UR 83 LL LR Trigger parameters Electronic treatment of the signal Threshold Threshold and trigger parameters Often done on the size, it allows to reduce the number of events without interest to not saturate the system Volt 1 Measurement of amplification Threshold level Regions permit to Isolate groups of interest, better discrimination by coloration, statistic calculations Data analysis Granulocytes Monocytes 1 Time (microsec.) Volt 1 Measurement of amplification Threshold level FSC Lymphocytes 1 Time (microsec.) FSC

5 Intensity Fluorescence Peak events events Data analysis Data analysis Gates Permit to combine logical regions, to define subgroups and to restrict the analyze on interesting cells signals to characterize them (statistics) R1 R1 R2 G /G 1 G 2 /M Ungated Counts A few examples 481 R1 mean : 6,45 36 R1 R1 : 68,94% R2 mean : 333,75 R2 : 3,96% 24 FL2-Log_Height Comp Percentage 1 5 R2 R3 R2 : 1,29 R3 :, overlay Doublets S Gated R1 and R FL1-Log_Height 1 1 R5 R5 :,72 R4 R4 : 97, FL1-Log_Height Comp 2C 4C Booleans equations etc. AND OR NAND NOR Doublet elimination Signal diffraction, refraction and reflection Laminar flow Refraction (dead or alive) Laser Diffraction (size) Excitation light Refracted light G1 G2 or M Doublet G1 2 G2 Excitation light Refraction is principally between 2 and 12 angles: FSC 1 G1 2 x G1 2n Reflection (cell surface, nucleus, granules ) 4n Reflected light Integral Area (relative value) Height Peak (relative value) 1 1 Temps Area Propidium Iodide Diffraction is principally between and - 4 angles: FSC Excitation light Reflected light Reflection is principally at 9 : SSC Physical properties Discrimination between living and dead cells Granulocytes Deaths Cells Homogeneous cell size Living cells Forward scatter Monocytes Heterogeneous cell size Lymphocytes Forward scatter

6 Intensity Fluorochrome characteristics Fluorochrome Molecule induces an electronic transition which then induces fluorescence. Associated to a macromolecule, it is called fluorophore Brightness fluorochromes Extinct coefficient multiplied by quantum output Excitation spectrum are compatible with the light source ABS EM wavelegnth (l) Quantum output Ratio between the number of emitted photons and the number of absorbed photons CD8-PerCP CD8-FITC CD8-ECD CD8-APC Extinct coefficient e Measurement of a reference fluorophore at a wavelength at 1M in a 1cm tank. (the more the value the more the fluorescence is elevated) Signal stability Signal stochiometry CD8-PC7 CD8-PC5 CD8-PE Choice of fluorochromes Spectral overlapping The excitation spectrum are compatible with your system BUT for multicolor is very difficult Use brightest fluorochromes for least expressed proteins Use dimmest fluorochromes for most highly expressed proteins Choose association of fluorochromes to avoid overlaps... hence limit spectral overlaps between fluorochromes and calculate compensation two methods for compensation : Medians method (manual) Slope method (automatic with new generation system) Spectral overlapping A contamination percentage of a fluorochrome by another Medians method (Manual compensation) FL1 FL2 Tubes must contain negatives cells and monomarked cells (or beads) 53/4 58/3 Photomultipliers voltage has to be high enough, allowing to have negatives cells in first decade B A Gate must include positives and negatives cells of a same autofluorescence (ex gate on lymphocytes). Adjust the compensation so as to positives and negatives cells, have same median Photomultiplier FL2 detects FITC fluorescence (A) Photomultiplier FL1 detects PE fluorescence (B) The calculated shift must be then entered in the system This procedure must be done on each fluorophore (do not forget to reset all parameters

7 Intensity Intensity Compensation Medians method A label (not a color) is attributed to each detector. The compensation method consists in removing a percentage from a signal to another signal Analog signal Compensation Fluo1 Fluo2 PE - FL2-Log_Height 53/4 58/3 1 5 R R3 Counts Fluo1 -FITC Counts Fluo2 -PE PMT Compensation etc. ADC Wavelength Fluo1 Fluo2 FL2-Log_Height Comp PE - FL2-Log_Height 53/4 58/3 R4 R FITC - FL1-Log_Height 1 5 R2 R Counts FITC - FL1-Log_Height PE - FL2-Log_Height Fluo1 -FITC Fluo2 -PE Counts Counts digital signal PMT ADC Compensation etc. Wavelength R4 R FITC FL1-Log_Height - FL1-Log_Height Comp Compensation PE-%FITC FITC - FL1-Log_Height FL2-Log_Height PE - FL2-Log_Height Comp From C. Aït Mansour - Miltenyi Compensation Log 4 decades Log 5 decades hyperlog Compensation Make compensation settings with bright fluorophores Do not touch values of PMTs after compensation settings No compensation Compensation From C. Aït Mansour - Miltenyi Required controls Dilution of Antibodies Required controls Example 5 colors N Tube FITC PE PE-TR PE-CY5 PE-CY7 1 expérimental CD3 CCR7 CD45 RO CD27 CD8 2 non coloré Ctrl isotypique t t t t t 4 monomarquage CD3 -/t -/t -/t -/t 5 monomarquage -/t CCR7 -/t -/t -/t 6 monomarquage -/t -/t CD45 RO -/t -/t 7 monomarquage -/t -/t -/t CD27 -/t 8 monomarquage -/t -/t -/t -/t CD8 Useful controls : FMO (Fluorescence minus one) 9 Ctrl régions - CCR7 CD45 RO CD27 CD8 1 Ctrl régions CD3 - CD45 RO CD27 CD8 11 Ctrl régions CD3 CCR7 - CD27 CD8 12 Ctrl régions CD3 CCR7 CD45 RO - CD8 13 Ctrl régions CD3 CCR7 CD45 RO CD27 - Titrate antibodies Secondary Ab 1/1 Secondary Ab 1/5 Primary Ab 1/25 1/5 1/1 1/2 Control with the same isotype and the same dilution as the specific antibody Cytométry 69A : (26)

8 Spreading data Unstimulated control Cytométry 69A : (26) Antigens/ receptors Excitation Emission AMCA Pacific blue FITC Sensible to ph Phycoérythrine 495, 532, PE-Rouge Texas* Red 613, ECD PE-Cyanine Tricolor, quantum red. Visible light sensibility Allophycocyanine PE-Cyanine , 532, PE-Cyanine CY7 could be altered by the fixation APC-Cy Nucleic acids Excitation Emission DAPI, Hoechst A-T bases Hoechst A-T bases, vital Sytox blue Intercalate, viability Cell trace calcein violet AM hydrophobic YO-YO ADN Acridine Orange 5 53, 64 ADN/ ARN TO-TO ADN Chromomycine G-C bases Pyronine Y ARN Propidium Iodure 536 (36 et 488) 617 Intercalate : ADN and/or ARN, viability Alexa : 35, 45, 43, 488, 532, 568, 594, 61, 633, 647, 66, 68, 7, 75 Insensible to ph, soluble in water EMA, ethydium monoazide 51 6 Viability, covalent/ photo-achievable PE/CY5 fixed monocytes and B lymphocytes of mice SJL, AKR, NOD Rappel PE-CY5 excited at 488 nm by the emit energy transferred from PE but also by the laser 633 nm via CY5, compensations could be elevated or difficult to realize so try to replace PE-CY5 by PE- CY5.5 or PE-CY7 in a combination with APC 7 A-actinomycine D G-C bases, viability Amine reactive dyes : an effective tool to discriminate live and dead cells in polychromatic flow cytometry. Perfetto SP, Chattopadhyay PK, Lamoreaux L, Nguyen R, Ambrozak D, Koup RA, Roderer M,. J Immunol Metghods. 26 Jun 3;313(1-2): Cellular functions Excitation Emission Monochlorobimane glutathion INDO-1-AM / 41 Free/ bound Ca2+ Ex : Nucleic acid dies FLUO Free non fluo/ bound Ca2+ fluo Fura Red Free fluo/ bond CA2+ non fluo DIOC4 à 6, JC-1, CMXRos Rh Mitochondrial potential NAO (nonyl acridine orange) BCECF 5 52/ 62 Mitochondrial mass membrane SNARF / 67 ph6/ 7,5 CFSE ph6/ 9 FDG Cellular proliferation Fluoresceine Diacetate FDA B-galactosidase Apoptosis Excitation Emission Phiphilux Caspases-3 Annexin-V FITC Phosphatidyl-serine dutp-fitc OH DNA ends YO-PRO ADN SYTO ADN ECFP EGFP EYFP DsRed 49, mrfp Spectrum excitation Permeant Specificity Toxicity U.V : Hoechst, DAPI 488 : IP, 7-AAD 633 : TO-PRO3 Hoechst Vybrant DyeCycle Violet stain Non : IP A-T : Hoechst C-G : 7-AAD, Chromomicyne Hoechst DRAQ5

9 Cell Flow Sorting Continuous jet sorting : principle Partec System Becton System Cell Flow sorting Separate cells in a flux according to their properties Fluid Piezo-electric valve Fluorescence-Activated Cell sorting FACS is a trademark of Becton Dickinson Cells path when opened valve (unsorted cells) Collection tube Cells path when closed valve (sort) Center collection tube : sort Off center collection tube : unsorted Cf C. Jayat Atelier INSERM 13 Sort jet-in-air Electrostatic sorting nozzle stroboscope Droplet formation 1- Adjust sample and liquid sheath pressure. 2- Induce an amplitude variation and a variable frequency on the flow Drop delay Time needed for one cell to go from the analyze point to the droplet formation Deviation plates Target cell identification To analyze cells and to define sorting windows Deflected jets Droplet charge The drop charge determines the applicable tension on a droplet. Charged droplet will be deviated from the normal path Waste bin Droplet deviation An electrostatic field deviate the droplet Cell sorting jet-in-air : principle A Sort strategy B Electric impulsion Variable position of the cell in the flow (coincidence notion) Detector nozzle Laser beam Time Time 1 Time Time 1 Intersection flux / laser Drop Delay Last attached droplet (DGA)? A sorting envelop is defined depending on the direction needed for cell sorting Deflection charged plate Waste bin Collecting tubes support Purity 1 droplet Detection of coincidence ON Purity/ Output 2 droplet Detection of coincidence ON Output/ Purity 3 droplet Detection of coincidence ON Output 3 droplet Detection of coincidence OFF

10 MPM2 Alexa 488 fluorescence Cyclin A2 FITC Cell Number Cell Number Application field Studies Fundamental and applicative research Medicine (hematology, immunology, cancerology etc), Industry: food processing, environment, cosmetology, pharmacology and toxicology. Morphological analysis size, numeration, cellular viability, Antigenic analysis (membrane and cytoplasme) phenotype of blood cells, hematology, leukemia's, antigenic quantification, allergologic tests, prenatal diagnosis, specificity and antibody titration... Functional analysis cellular signalization, metabolic activity, membrane integrity, proteins and genetic expression, ionic flux, intracellular PH... Nucleic acid analysis Cell sorting DNA and RNA content, cellular cycle, proliferation, apoptosis, cellular viability... physiological criterions (fluorochromes), fluorescents telltale genes (GFP ), phases of the cellular cycle, males or female spermatozoids... Flow cytometry and safety DNA/ cell cycle Biological and chemical risks Phase G/G1 G1 44,6% S 21,8% G2+M 33,6% Linear markers give an indication but it is just an estimation Electrical risks G1 41,6% LASER risks Phase S Phase G2 + M S 28,8% G2+M 29,6% Aerosols risks Propidium Iodure Sound risks Mathematic models are more precise without being perfect MultiCycle Essential conditions for DNA content analysis Cell cycle Identification of mitosis cells G/G1 Utilization of a valid staining method for DNA Optimal use of the cytometer (marble of calibration, DNA beginning of the fluorescence, correct voltage) Apparition of the CyclineA2 during the cycle IgG1 S G2/M Passing time : 2 events per second Coefficient of variation peak GG1 < 5% Ctrl Weak fragment proportion (<2%) Eliminate aggregates M 1 cells minimum to calculate a cycle Propidium Iodide Propidium Iodide G2 Have diploid cells as reference (ex : chicken red blood cells ) DNA content PI fluorescence J. Sobczak UMR 7622 I. Gasnereau UMR 7622

11 CD56 events Cell number DNA peak Modulation of the cell cycle Divers inhibitors effects of topo-isomerases (treatment during 16 hours) Cell cycle a tumorous cell line treated by antimitotic agent % of cells in G2: Reference: 16% R1 R1 R1 R1 drug.1: 26% 2c drug.3: 5% drug.9: 83% 1c 4c Asynchrones cells J. Sobczak UMR 7622 Camptothecine 1 mm Etoposide 25 nm ICRF mm Agnès Chassevent - 29 Paul Papin Center - Angers Cell proliferation Click-it EdU follows a protocol of Aldehyde fixation and detergent permeabilization Fluorescence Ubiquitination Cell Cycle Indicator (FUCCI) Phase S G1 + G G2 + M Fix for 15 minutes, wash Permeabilize for 3 minutes, wash Incubate in click labeling cocktail for 3 minutes, wash Optimal : incubate with cell cycle stain for 15-3 minutes Analyze Control cells : EdU cells EdU-incorporated FL3-H J. Sobczak UMR 7622 Analysis of cell division Proliferation of T lymphocytes after 4 days of stimulation D D4 D6 *MDR Resistance MultiDrogue Clinical study of MDR* N 1 N 2 N 3 CFSE (carboxyfluoresceine diacetate, succimidyl ester) with verapamil without verapamil Rhodamine 123 A. Saoudi Drénou, B

12 Propidum iodide # Cells GFP FL1-H Ki-67 FITC Ki-67 FITC # Cells Effect of transfected gene on cell cycle Ki-67 /DNA transfected gene % 32% of cells Ki FL4-H Hoechst FL4-H Hoechst % Propidium Iodide (DNA) Propidium Iodide (DNA) Derek Davies, Cancer Research UK Agnès Chassevent - 29 Paul Papin Center Angers Apoptotic event Exposure of phosphatidylserine to external face cytoplasmic membrane Apoptotic event intracellulare Ca++ increase Indo1 emits blue fluorescence when it is free Indo 1 emits purple fluorescence when it is binding Ca++ They measure ratio indo bind/indo free according to time T human lymphocytes non stimulated T human lymphocytes antigen timulated Annexin V- FITC S. Valitutti Apoptotic event TUNEL (TdT-mediated X-dUTP nick end labelling) pic sub-g1 DNA Fragmentation 2n 4n J.F. Mayol CRSSA - Grenoble

13 FL3 - Beads FL3 - Beads events events 6 Stem cells DNA/ Cell cycle - Sorting Side Population (bone marrow of mouse) Hoechst (laser UV or violet) emission : blue AND red Muscle G /G 1 Apo 33% G /G 1 47% S 14% G 2 +M 6% Hematopoietic Apo. S G 2+M Adipocytes Osteoblastes Propidium Iodide 124 G /G 1 Overlay after sorting Endotheliales S G 2 +M Detection based on efflux Hoechst M.C. Gendron Propidium Iodide Multicolor analysis Multicolor 6 coulors 2 6 population CD3 FITC CD38 PE CD45 PerCP-C5.5 CD4 PE-Cy7 CD19 APC CD8 APC-Cy7 after sorting Multiplex Detection of small events Ex : Cytometry Bead Area BD Biosciences assays on beads New cytometers ail-8-pe ail-1b-pe Different Intensity of fluorescence read on FL3 ail-6-pe sensitivity, optic, electronic, informatic Detection of small particles (.2 µm) according to their size and their fluorescences and of intensity of their fluorescence ail-1-pe atnf-a-pe ail-12-pe Fluorescences probes FL2 - PE FL2 - PE Ann Biol Clin, vol. 67, n 4, juillet-aout 29

14 Detection of microorganisms Detection of microorganisms Resolution of multiple small species by forward and side scatter Chlorophylle Phycoerythrine Phycocyanine Picoeucaryotes Autofluorescence Synechococcus Prochlorococcus Marine Biology Medical Biology Crucial role of microorganisms in the functioning of earth s biosphere No Antibiotic Antibiotic added Examples of phytoplancton population analysis coming from different coastal ecosystems with each cell being identified by their light scattering properties (size) and by their red chlorophyllfluorescence excited with a 488 nm laser. FS vs SS FS vs SS Light scatter cytograms of E.coli cells before and after addition of ampicillin. Data obtained from, Bio-Rad, USA. Food Biology Plant Biology DNA in plants Detection of Listeria in milk products with CMF using fluorescent antibodies automatical analysis methods in milk products Listeria monocytogenes Not just pathogenics... Viability studies of beer yeast used in australian brewing industry S.J. Ochatt

15 Supplementary methods A hybrid Quantification Discrimination Visualization Photobleaching Reproductibility Observed events Cell sorting Complementarity Flow cytometry +++ individual YES Microscopy +/- individual Some hundreds +/- YES The ImageStream is a high-speed automated microscope that captures images in flow (low rate) ImageStreamX Amnis cells in flow Brightfield illuminator laser detector autofocus Spectral decomposition element Velocity detector Technological innovation LEAP is an imaging cell sorter (shooting laser) Technological innovation Attune a cytometer an acoustical focusing LEAP Cyntellect Attune Life Technologies Schematic of acoustic focusing principle. Technological innovation CyTOF : metal-labeled cells are introduced individually into an Inductively Coupled Plasma Cells are atomized and ionized in an argon plasma Atomic ions are extracted into the ion optics and Time-Of-Flight region They are separated by mass and counted Quantum Dots, are semiconductors whose electronic characteristics are closely related to the size of individual crystal. Excitation par UV Perspective Analysis of up to 1 stable isotope labels in a single cell No overlap between detection channels, no need to compensate No autofluorescence An unlabeled cell is invisible to the system 1 cells/ sec Efficiency of the cell intruction system 2-3% Data output in text and FCS standards The smaller dot, the closer it is to the blue of the spectrum, and the larger dot, the closer to the red. Dots can exciting by U.V or another laser. CyTOF system DVS Sciences Bandura, D.R., et al. Anal Chem 81 (16): , 29. Quantum Dot Corporation

16 Recent technological developments Conclusion Sensitivity increase and multiparameters «ELISA on beads» for detection and quantification of several products in the same sample Panel of cytokines in plasma Receptor in supernatant or in cell lysate RNA messengers «microarrays» on beads CMF is a technology turned to the polychromy Sensitivity increase and number of analyzed parameters open prospects into studies of microparticules Current technological developments QuantumDots (nanocristaux) Documentation Books and journals La cytométrie en flux. X. Ronot, D. Grunwald, J.F. Mayol & J. Boutennat. Tec et Doc. Lavoisier. Paris. 26. Practical flow cytometry. Shapiro H.M. 4 ème édition. 23. Wiley-Liss ed. Cycle cellulaire et cytométrie en flux. Grunwald, J.F. Mayol & X. Ronot. Tec et Doc. Lavoisier. Paris. 21. Cytometry : Articles Documentation Hoffman RA,Wang L, Bigos M, NolanJP : NIST/ISAC standardization study : variability in assignment of intensity values to fluorescence standard beads and in cross calibration of standard beads to hard dyed beads. Cytometry. 81A : (212) Zbigniew Darzynkiewicz : Critical Aspects in Analysis of Cellular DNA Content. Curr Protoc Cytom. 211 April; CHAPTER: Unit 7.2. (211) Roderer : Optimizing a multicolor immunophenotyping assay. Clin Lab Med 27 : (27) Roederer : Quantum dot semiconductor nanocrystal for immunophenotyping by polychromatic flow cytometry. Nat Med. Aug ; 12(8) : (26) Maecker HT, Trotter J : Flow Cytometry Controls, Instrument Setup, and the Determination of Positivity.. Cytometry 69A : (26) Perfetto, S. P., Chattopadhyay, P. K. and Roederer, M. : "17-Color Flow Cytometry: Unraveling the Immune System." Nat Rev Immunol 4: (24) Robert P. Wersto, et al : Doublet Discrimination in DNA Cell-Cycle Analysis. Cytometry. 46A : (21) SPACE Documentation Web cytometry Association Française de Cytométrie : OCEAN International Society for Analytical Cytology : Life technologies : Analyse cellulaire Flow cytometry resources flow cytometry tutorials EARTH List of discussion TARA Liste de discussion : Free software WEASEL :

Introduction to flow cytometry

Introduction to flow cytometry Introduction to flow cytometry Flow cytometry is a popular laser-based technology. Discover more with our introduction to flow cytometry. Flow cytometry is now a widely used method for analyzing the expression

More information

Introduction to Flow Cytometry

Introduction to Flow Cytometry Introduction to Flow Cytometry presented by: Flow Cytometry y Core Facility Biomedical Instrumentation Center Uniformed Services University Topics Covered in this Lecture What is flow cytometry? Flow cytometer

More information

Flow Cytometry. flow cytometer DNA apoptosis ph

Flow Cytometry. flow cytometer DNA apoptosis ph Flow Cytometry flow cytometer DNA apoptosis ph flow cytometry flow cytometer (a) (b) cell counting instrument (c) 1960 ink-jet technology 17 19 1940 1950 fluorescence microscopy fluorescent dye DNA polyclonal

More information

Introduction to Flow Cytometry

Introduction to Flow Cytometry Outline Introduction to Flow Cytometry Basic Concept of Flow Cytometry Introduction to Instrument Subsystems Daisy Kuo Assistant Product Manager E-mail: daisy_kuo@bd.com BDBiosciences Application Examples

More information

Katharina Lückerath (AG Dr. Martin Zörnig) adapted from Dr. Jörg Hildmann BD Biosciences,Customer Service

Katharina Lückerath (AG Dr. Martin Zörnig) adapted from Dr. Jörg Hildmann BD Biosciences,Customer Service Introduction into Flow Cytometry Katharina Lückerath (AG Dr. Martin Zörnig) adapted from Dr. Jörg Hildmann BD Biosciences,Customer Service How does a FACS look like? FACSCalibur FACScan What is Flow Cytometry?

More information

MEASURABLE PARAMETERS: Flow cytometers are capable of measuring a variety of cellular characteristics such as:

MEASURABLE PARAMETERS: Flow cytometers are capable of measuring a variety of cellular characteristics such as: INTRODUCTION Flow Cytometry involves the use of a beam of laser light projected through a liquid stream that contains cells, or other particles, which when struck by the focused light give out signals

More information

CyAn : 11 Parameter Desktop Flow Cytometer

CyAn : 11 Parameter Desktop Flow Cytometer CyAn : 11 Parameter Desktop Flow Cytometer Cyan ADP 3 excitation lines 488nm, 635nm, and UV or violet 11 simultaneous parameters FSC, SSC, and 7-9 colors with simultaneous width, peak, area, and log on

More information

Flow Cytometry. What is Flow Cytometry? What Can a Flow Cytometer Tell Us About a Cell? Particle Size. Flow = Fluid Cyto = Cell Metry = Measurement

Flow Cytometry. What is Flow Cytometry? What Can a Flow Cytometer Tell Us About a Cell? Particle Size. Flow = Fluid Cyto = Cell Metry = Measurement What is Flow Cytometry? Flow Cytometry Basic Principle and Applications BD Biosciences Daisy Kuo (daisy_kuo@bd.com) Flow = Fluid Cyto = Cell Metry = Measurement A variety of measurements are made on cells,

More information

Flow Cytometry A Basic Overview

Flow Cytometry A Basic Overview Flow Cytometry A Basic Overview Overview Flow cytometry is a powerful technology for investigating many aspects of cell biology and for isolating cells of interest. Flow cytometry utilizes highly focused,

More information

Multicolor Flow Cytometry: Setup and Optimization on the BD Accuri C6 Flow Cytometer

Multicolor Flow Cytometry: Setup and Optimization on the BD Accuri C6 Flow Cytometer Multicolor Flow Cytometry: Setup and Optimization on the BD Accuri C6 Flow Cytometer Presented by Clare Rogers, MS Senior Marketing Applications Specialist BD Biosciences 23-13660-00 Webinar Overview Multicolor

More information

APPLICATION INFORMATION

APPLICATION INFORMATION DRAFT: Rev. D A-2045A APPLICATION INFORMATION Flow Cytometry 3-COLOR COMPENSATION Raquel Cabana,* Mark Cheetham, Jay Enten, Yong Song, Michael Thomas,* and Brendan S. Yee Beckman Coulter, Inc., Miami FL

More information

Immunophenotyping peripheral blood cells

Immunophenotyping peripheral blood cells IMMUNOPHENOTYPING Attune Accoustic Focusing Cytometer Immunophenotyping peripheral blood cells A no-lyse, no-wash, no cell loss method for immunophenotyping nucleated peripheral blood cells using the Attune

More information

Introduction to Flow Cytometry -- BD LSR II. What is Flow Cytometry? What Can a Flow Cytometer Tell Us About a Cell? Particle Size

Introduction to Flow Cytometry -- BD LSR II. What is Flow Cytometry? What Can a Flow Cytometer Tell Us About a Cell? Particle Size Introduction to Flow Cytometry -- BD LSR II Daisy Kuo 郭 正 佼 Assistant Product Manager BD Biosciences Daisy_kuo@bd.com What is Flow Cytometry? Flow = Fluid Cyto = Cell Metry = Measurement A variety of measurements

More information

Three Rules for Compensation Controls

Three Rules for Compensation Controls From FlowJo s Daily Dongle Three Rules for Compensation Controls First and foremost, there must be a single-stained control for every parameter in the experiment! In addition, there are three rules for

More information

These particles have something in common

These particles have something in common These particles have something in common Blood cells Chromosomes Algae Protozoa Certain parameters of these particles can be measured with a flow cytometer Which parameters can be measured? the relative

More information

FLOW CYTOMETRY: PRINCIPLES AND APPLICATIONS. By: Douaa Moh. Sayed

FLOW CYTOMETRY: PRINCIPLES AND APPLICATIONS. By: Douaa Moh. Sayed FLOW CYTOMETRY: PRINCIPLES AND APPLICATIONS By: Douaa Moh. Sayed Definition Flow cytometry is a technique for counting, examining, and sorting microscopic particles suspended in a stream of fluid. It allows

More information

Application Note. Selecting Reagents for Multicolor Flow Cytometry. Holden Maecker and Joe Trotter BD Biosciences, San Jose

Application Note. Selecting Reagents for Multicolor Flow Cytometry. Holden Maecker and Joe Trotter BD Biosciences, San Jose Selecting Reagents for Multicolor Flow Cytometry Holden Maecker and Joe Trotter BD Biosciences, San Jose Contents 1 The basics: Know your instrument 2 Fluorochromes: Go for the bright 3 Colors and specificities:

More information

Uses of Flow Cytometry

Uses of Flow Cytometry Uses of Flow Cytometry 1. Multicolour analysis... 2 2. Cell Cycle and Proliferation... 3 a. Analysis of Cellular DNA Content... 4 b. Cell Proliferation Assays... 5 3. Immunology... 6 4. Apoptosis... 7

More information

FlowSight. Flow cytometry with vision

FlowSight. Flow cytometry with vision FlowSight Flow cytometry with vision Flow cytometry with vision Introducing FlowSight Capable: Sensitive and flexible for every need Intuitive: Easy-to-use, with imagery for every cell Affordable: Designed

More information

Using the BD TM Cytometer Setup and Tracking (CS&T) System for Instrument Characterization and Performance Tracking

Using the BD TM Cytometer Setup and Tracking (CS&T) System for Instrument Characterization and Performance Tracking Using the BD TM Cytometer Setup and Tracking (CS&T) System for Instrument Characterization and Performance Tracking Mark KuKuruga Senior Technical Applications Specialist BD Biosciences 23-14462-00 Outline

More information

Flow cytometry basics fluidics, optics, electronics...

Flow cytometry basics fluidics, optics, electronics... Title Flow cytometry basics fluidics, optics, electronics... RNDr. Jan Svoboda, Ph.D. Cytometry and Microscopy Core Facility IMB, CAS, v.v.i Vídeňská 1083 Fluorescence Fluorescence occurs when a valence

More information

Cell Cycle Tutorial. Contents

Cell Cycle Tutorial. Contents Cell Cycle Tutorial Contents Experimental Requirements...2 DNA Dyes...2 Protocols...3 PI Parameter & Analysis Setup...4 PI Voltage Adjustments...6 7-AAD Parameter Setup...6 To-Pro3 Parameter Setup...6

More information

Flow Cytometry for Everyone Else Susan McQuiston, J.D., MLS(ASCP), C.Cy.

Flow Cytometry for Everyone Else Susan McQuiston, J.D., MLS(ASCP), C.Cy. Flow Cytometry for Everyone Else Susan McQuiston, J.D., MLS(ASCP), C.Cy. At the end of this session, the participant will be able to: 1. Describe the components of a flow cytometer 2. Describe the gating

More information

Supplementary Material. Free-radical production after post-thaw incubation of ram spermatozoa is related to decreased in vivo fertility

Supplementary Material. Free-radical production after post-thaw incubation of ram spermatozoa is related to decreased in vivo fertility 10.1071/RD14043_AC CSIRO 2015 Supplementary Material: Reproduction, Fertility and Development, 2015, 27(8), 1187 1196. Supplementary Material Free-radical production after post-thaw incubation of ram spermatozoa

More information

Introduction to Flow Cytometry:

Introduction to Flow Cytometry: Introduction to Flow Cytometry: A Learning Guide Manual Part Number: 11-11032-01 April, 2000 BD Biosciences 2350 Qume Drive San Jose, CA 95131-1807 1-800-448-2347 Introduction to Flow Cytometry: A Learning

More information

INSIDE THE BLACK BOX

INSIDE THE BLACK BOX FLOW CYTOMETRY ESSENTIALS INSIDE THE BLACK BOX Alice L. Givan Englert Cell Analysis Laboratory of the Norris Cotton Cancer Center Dartmouth Medical School HOW NOT TO BE A FLOW CYTOMETRIST Drawing by Ben

More information

Technical Bulletin. An Introduction to Compensation for Multicolor Assays on Digital Flow Cytometers

Technical Bulletin. An Introduction to Compensation for Multicolor Assays on Digital Flow Cytometers An Introduction to Compensation for Multicolor Assays on Digital Flow Cytometers BD Biosciences, San Jose, CA Contents 2 Introduction to compensation 5 Tips for setting up compensation 10 Tools for easy,

More information

Boundary-breaking acoustic focusing cytometry

Boundary-breaking acoustic focusing cytometry Boundary-breaking acoustic focusing cytometry Introducing the Attune NxT Acoustic Focusing Cytometer a high-performance system that s flexible enough for any lab One of the main projects in my laboratory

More information

No-wash, no-lyse detection of leukocytes in human whole blood on the Attune NxT Flow Cytometer

No-wash, no-lyse detection of leukocytes in human whole blood on the Attune NxT Flow Cytometer APPLICATION NOTE Attune NxT Flow Cytometer No-wash, no-lyse detection of leukocytes in human whole blood on the Attune NxT Flow Cytometer Introduction Standard methods for isolating and detecting leukocytes

More information

CyFlow SL. Microbiology. Detection and Analysis of Microorganisms and Small Particles

CyFlow SL. Microbiology. Detection and Analysis of Microorganisms and Small Particles CyFlow SL Microbiology Detection and Analysis of Microorganisms and Small Particles 01 COMPANY Flow Cytometry made in Germany New sophisticated applications and increasing requirements for reliable results

More information

Application Information Bulletin: Set-Up of the CytoFLEX Set-Up of the CytoFLEX* for Extracellular Vesicle Measurement

Application Information Bulletin: Set-Up of the CytoFLEX Set-Up of the CytoFLEX* for Extracellular Vesicle Measurement Application Information Bulletin: Set-Up of the CytoFLEX Set-Up of the CytoFLEX* for Extracellular Vesicle Measurement Andreas Spittler, MD, Associate Professor for Pathophysiology, Medical University

More information

Instrument Characterization and Performance Tracking for Digital Flow Cytometers

Instrument Characterization and Performance Tracking for Digital Flow Cytometers Instrument Characterization and Performance Tracking for Digital Flow Cytometers BD Biosciences Cytometer Set-up & Tracking (CS&T) System For Research Use Only. Not for use in diagnostic or therapeutic

More information

Using BD FACSDiva CST To. Evaluate Cytometer Performance, Create Custom Assay Settings. and

Using BD FACSDiva CST To. Evaluate Cytometer Performance, Create Custom Assay Settings. and Using BD FACSDiva CST To Evaluate Cytometer Performance, Create Custom Assay Settings and Implement Cross-Instrument and Cross-Site Standardization of Assays PART 2 Alan M. Stall Director, Advanced Cytometry

More information

Islet Viability Assessment by Single Cell Flow Cytometry

Islet Viability Assessment by Single Cell Flow Cytometry Islet Viability Assessment by Single Cell Flow Cytometry Page 1 of 8 Purpose: To comprehensively assess the viability of the islet cell preparation prior to transplantation. Tissue Samples: A sample containing

More information

Cell Viability Measurement

Cell Viability Measurement Cell Viability Measurement Viability is a measure of the metabolic state of a cell population which is indicative of the potential for growth Most common method: membrane integrity Trypan blue exclusion:

More information

UNIVERSITY OF PÉCS MEDICAL SCHOOL FLOW CYTOMETRY AND CELL SEPARATION BIOPHYSICS 2. 2015 4th March Dr. Beáta Bugyi Department of Biophysics Flow cytometry and cell separation FLOW = STREAM OF FLUID in a

More information

BD FACSDiva 4.1 - TUTORIAL TSRI FLOW CYTOMETRY CORE FACILITY

BD FACSDiva 4.1 - TUTORIAL TSRI FLOW CYTOMETRY CORE FACILITY BD FACSDiva 4.1 - TUTORIAL TSRI FLOW CYTOMETRY CORE FACILITY IMPORTANT NOTES BEFORE READING THIS TUTORIAL This is a very expensive piece of equipment so PLEASE treat it with respect! After you are done

More information

COMPENSATION MIT Flow Cytometry Core Facility

COMPENSATION MIT Flow Cytometry Core Facility COMPENSATION MIT Flow Cytometry Core Facility Why do we need compensation? 1) Because the long emission spectrum tail of dyes causes overlap like with the fluorophores FITC and PE. 2) For sensitivity reasons,

More information

CELL CYCLE BASICS. G0/1 = 1X S Phase G2/M = 2X DYE FLUORESCENCE

CELL CYCLE BASICS. G0/1 = 1X S Phase G2/M = 2X DYE FLUORESCENCE CELL CYCLE BASICS Analysis of a population of cells replication state can be achieved by fluorescence labeling of the nuclei of cells in suspension and then analyzing the fluorescence properties of each

More information

Spherotech, Inc. 27845 Irma Lee Circle, Unit 101, Lake Forest, Illinois 60045 1

Spherotech, Inc. 27845 Irma Lee Circle, Unit 101, Lake Forest, Illinois 60045 1 78 Irma Lee Circle, Unit 0, Lake Forest, Illinois 00 SPHERO TM Technical Note STN- Rev B 008 DETERMINING PMT LINEARITY IN FLOW CYTOMETERS USING THE SPHERO TM PMT QUALITY CONTROL EXCEL TEMPLATE Introduction

More information

BD FACSComp Software Tutorial

BD FACSComp Software Tutorial BD FACSComp Software Tutorial This tutorial guides you through a BD FACSComp software lyse/no-wash assay setup run. If you are already familiar with previous versions of BD FACSComp software on Mac OS

More information

use. 3,5 Apoptosis Viability Titration Assays

use. 3,5 Apoptosis Viability Titration Assays Introduction Monitoring cell viability can provide critical insights into the effectiveness of biological protocols and the stability of biological systems including: the efficacy of cell harvesting procedures,

More information

Compensation in Flow Cytometry

Compensation in Flow Cytometry Compensation in UNIT.4 The term compensation, as it applies to flow cytometric analysis, refers to the process of correcting for fluorescence spillover, i.e., removing the signal of any given fluorochrome

More information

Compensation: An Instrumental Perspective

Compensation: An Instrumental Perspective Compensation: An Instrumental Perspective Why Digital? Visualization Issues Boston User s Group September 10, 2003 Joe Trotter Joe_Trotter@bd.com Review: Instrument Sensitivity Measuring Sensitivity -

More information

Technical Bulletin. Standardizing Application Setup Across Multiple Flow Cytometers Using BD FACSDiva Version 6 Software. Abstract

Technical Bulletin. Standardizing Application Setup Across Multiple Flow Cytometers Using BD FACSDiva Version 6 Software. Abstract arch 212 Standardizing Application Setup Across ultiple Flow Cytometers Using BD FACSDiva Version 6 Ellen einelt, ervi Reunanen, ark Edinger, aria Jaimes, Alan Stall, Dennis Sasaki, Joe Trotter Contents

More information

Principles of Flowcytometry

Principles of Flowcytometry Objectives Introduction to Cell Markers: Principles of Flowcytometry Michelle Petrasich NZIMLS Scientific Meeting August 24, 2010, Paihia What are cell markers How do we detect them Production of Monoclonal

More information

Compensation Controls Data Visualization Panel Development Gating Quantum Dots

Compensation Controls Data Visualization Panel Development Gating Quantum Dots Compensation Controls Data Visualization Panel Development Gating Quantum Dots FITC Single Stain Control FITC PE Argon Laser FL1 FL2 450 500 550 600 FITC Compensation Control Unwanted signal detected in

More information

FACS Laboratory. BD LSRs Operator Training. Training Guide. http://london-research-institute.org.uk/technologies/facs

FACS Laboratory. BD LSRs Operator Training. Training Guide. http://london-research-institute.org.uk/technologies/facs FACS Laboratory facs_lab@cancer.org.uk Training Guide http://london-research-institute.org.uk/technologies/facs BD LSRs Operator Training LRI FACS lab 1 Components 1.1 Basic parts overview.pg3-6 Overview

More information

Technical Bulletin. Threshold and Analysis of Small Particles on the BD Accuri C6 Flow Cytometer

Technical Bulletin. Threshold and Analysis of Small Particles on the BD Accuri C6 Flow Cytometer Threshold and Analysis of Small Particles on the BD Accuri C6 Flow Cytometer Contents 2 Thresholds 2 Setting the Threshold When analyzing small particles, defined as particles smaller than 3.0 µm, on the

More information

CELL CYCLE BASICS. G0/1 = 1X S Phase G2/M = 2X DYE FLUORESCENCE

CELL CYCLE BASICS. G0/1 = 1X S Phase G2/M = 2X DYE FLUORESCENCE CELL CYCLE BASICS Analysis of a population of cells replication state can be achieved by fluorescence labeling of the nuclei of cells in suspension and then analyzing the fluorescence properties of each

More information

Zecotek S Light Projection Network Marketing

Zecotek S Light Projection Network Marketing White Paper Zecotek Visible Fiber Laser Platform Enabling the future of laser technology Zecotek Photonics Inc. (TSX- V: ZMS; Frankfurt: W1I) www.zecotek.com is a Canadian photonics technology company

More information

a Beckman Coulter Life Sciences: White Paper

a Beckman Coulter Life Sciences: White Paper a Beckman Coulter Life Sciences: White Paper Violet-Excited nim-da Allows Efficient and Reproducible Cell Cycle Analysis on the Gallios Flow Cytometer Authors: Valdez, Ben 1. Carr, Karen 2. Norman, John

More information

Hoechst 33342 HSC Staining and Stem Cell Purification Protocol (see Goodell, M., et al. (1996) J Exp Med 183, 1797-806)

Hoechst 33342 HSC Staining and Stem Cell Purification Protocol (see Goodell, M., et al. (1996) J Exp Med 183, 1797-806) Hoechst 33342 HSC Staining and Stem Cell Purification Protocol (see Goodell, M., et al. (1996) J Exp Med 183, 1797-86) The Hoechst purification was established for murine hematopoietic stem cells (HSC)

More information

Chapter 10 Immunofluorescence

Chapter 10 Immunofluorescence Chapter 10 Immunofluorescence J. Paul Robinson PhD, Jennifer Sturgis BS and George L. Kumar PhD Immunofluorescence (IF) is a common laboratory technique used in almost all aspects of biology. This technique

More information

Below is a list of things you should be aware of before you schedule your sort.

Below is a list of things you should be aware of before you schedule your sort. Sorting at the Flow Cytometry Facility At the present time, the assistance of a trained cell sorter operator is needed for all sorting applications. As such, if you are planning a first time sort you will

More information

CyFlow SL. Healthcare Immunology. Portable FCM System for 3-colour Immunophenotyping

CyFlow SL. Healthcare Immunology. Portable FCM System for 3-colour Immunophenotyping CyFlow SL Healthcare Immunology Portable FCM System for 3-colour Immunophenotyping 01 COMPANY Flow Cytometry made in Germany New sophisticated applications and increasing requirements for reliable results

More information

123count ebeads Catalog Number: 01-1234 Also known as: Absolute cell count beads GPR: General Purpose Reagents. For Laboratory Use.

123count ebeads Catalog Number: 01-1234 Also known as: Absolute cell count beads GPR: General Purpose Reagents. For Laboratory Use. Page 1 of 1 Catalog Number: 01-1234 Also known as: Absolute cell count beads GPR: General Purpose Reagents. For Laboratory Use. Normal human peripheral blood was stained with Anti- Human CD45 PE (cat.

More information

EdU Flow Cytometry Kit. User Manual

EdU Flow Cytometry Kit. User Manual User Manual Ordering information: (for detailed kit content see Table 2) EdU Flow Cytometry Kits for 50 assays: Product number EdU Used fluorescent dye BCK-FC488-50 10 mg 6-FAM Azide BCK-FC555-50 10 mg

More information

Flow Cytometry Protocols

Flow Cytometry Protocols METHODS IN MOLECULAR BIOLOGY TM TM Volume 263 Flow Cytometry Protocols SECOND EDITION Edited by Teresa S. Hawley Robert G. Hawley 1 Flow Cytometry An Introduction Alice L. Givan Summary A flow cytometer

More information

Immunophenotyping Flow Cytometry Tutorial. Contents. Experimental Requirements...1. Data Storage...2. Voltage Adjustments...3. Compensation...

Immunophenotyping Flow Cytometry Tutorial. Contents. Experimental Requirements...1. Data Storage...2. Voltage Adjustments...3. Compensation... Immunophenotyping Flow Cytometry Tutorial Contents Experimental Requirements...1 Data Storage...2 Voltage Adjustments...3 Compensation...5 Experimental Requirements For immunophenotyping with FITC and

More information

PROTOCOL. Immunostaining for Flow Cytometry. Background. Materials and equipment required.

PROTOCOL. Immunostaining for Flow Cytometry. Background. Materials and equipment required. PROTOCOL Immunostaining for Flow Cytometry 1850 Millrace Drive, Suite 3A Eugene, Oregon 97403 Rev.0 Background The combination of single cell analysis using flow cytometry and the specificity of antibody-based

More information

apoptosis detection Apoptosis assays for the Attune Acoustic Focusing Cytometer Apoptosis detection Attune Acoustic Focusing Cytometer

apoptosis detection Apoptosis assays for the Attune Acoustic Focusing Cytometer Apoptosis detection Attune Acoustic Focusing Cytometer apoptosis detection ttune coustic Focusing Cytometer poptosis detection poptosis assays for the ttune coustic Focusing Cytometer poptosis is a carefully regulated process of cell death that occurs as a

More information

Institut für Experimentelle Immunologie und Bildgebung

Institut für Experimentelle Immunologie und Bildgebung Page 1 von 6 Starting Up the System Start up the computer, start Windows and log in as IMCES_user start BD FACSDiva software with your Groupname Turn on the cytometer main power Wait a moment and Check

More information

Flow Data Analysis. Qianjun Zhang Application Scientist, Tree Star Inc. Oregon, USA FLOWJO CYTOMETRY DATA ANALYSIS SOFTWARE

Flow Data Analysis. Qianjun Zhang Application Scientist, Tree Star Inc. Oregon, USA FLOWJO CYTOMETRY DATA ANALYSIS SOFTWARE Flow Data Analysis Qianjun Zhang Application Scientist, Tree Star Inc. Oregon, USA Flow Data Analysis From Cells to Data - data measurement and standard Data display and gating - Data Display options -

More information

Standardization, Calibration and Quality Control

Standardization, Calibration and Quality Control Standardization, Calibration and Quality Control Ian Storie Flow cytometry has become an essential tool in the research and clinical diagnostic laboratory. The range of available flow-based diagnostic

More information

Standard Operating Procedure

Standard Operating Procedure 1.0 Purpose: 1.1 The characterisation of of main leukocyte subsets in peripheral blood cells from mice by flow cytometry. Reliable values of frequencies of leukocyte clusters are very much dependent on

More information

Too Many B Cells: Chronic Lymphocytic Leukemia and the Role of Flow Cytometry

Too Many B Cells: Chronic Lymphocytic Leukemia and the Role of Flow Cytometry Too Many B Cells: Chronic Lymphocytic Leukemia and the Role of Flow Cytometry by Debby R. Walser-Kuntz Biology Department Carleton College, Northfield, MN Taylor goes in to see her doctor, Dr. Chavez,

More information

CyFlow Space Your flexible flow cytometer

CyFlow Space Your flexible flow cytometer Your flexible flow cytometer www.sysmex-partec.com its flexibility gives you the space you need for your work Analysing cells and particles, be it from blood, plasma, tissue, plants, cell cultures or other

More information

International Beryllium Conference, Montreal, Canada March 10, 2005

International Beryllium Conference, Montreal, Canada March 10, 2005 Alternative Lymphocyte Proliferation Tests: BrdU and Flow Cytometry Based Tests International Beryllium Conference, Montreal, Canada March 10, 2005 Tim K. Takaro Department of Environmental and Occupational

More information

Flow Cytometry 101. Jodi Moore, PhD Jan 2012 Goldenson 113

Flow Cytometry 101. Jodi Moore, PhD Jan 2012 Goldenson 113 Flow Cytometry 101 Jodi Moore, PhD Jan 2012 Goldenson 113 Origins:? Dye Chemistry 1940-1980 s Electronics Microscopy Automated Clinical Cytology ID Apps Computers Cytometry vs. Flow Cytometry Microspectrophotometry

More information

powerful. Intuitive. Customizable. The new star of benchtop flow cytometry

powerful. Intuitive. Customizable. The new star of benchtop flow cytometry powerful. Intuitive. Customizable. The new star of benchtop flow cytometry About ACEA Established in 2002, ACEA Biosciences, Inc. develops cutting-edge cell analysis platforms for life science research.

More information

CFSE Cell Division Assay Kit

CFSE Cell Division Assay Kit CFSE Cell Division Assay Kit Item No. 10009853 Customer Service 800.364.9897 * Technical Support 888.526.5351 www.caymanchem.com TABLE OF CONTENTS GENERAL INFORMATION 3 Materials Supplied 4 Precautions

More information

Annexin V-EGFP Apoptosis Detection Kit

Annexin V-EGFP Apoptosis Detection Kit ab14153 Annexin V-EGFP Apoptosis Detection Kit Instructions for Use For the rapid, sensitive and accurate measurement of apoptosis in various samples This product is for research use only and is not intended

More information

Chapter 6. Antigen-Antibody Properties 10/3/2012. Antigen-Antibody Interactions: Principles and Applications. Precipitin reactions

Chapter 6. Antigen-Antibody Properties 10/3/2012. Antigen-Antibody Interactions: Principles and Applications. Precipitin reactions Chapter 6 Antigen-Antibody Interactions: Principles and Applications Antigen-Antibody Properties You must remember antibody affinity (single) VS avidity (multiple) High affinity: bound tightly and longer!

More information

CyTOF2. Mass cytometry system. Unveil new cell types and function with high-parameter protein detection

CyTOF2. Mass cytometry system. Unveil new cell types and function with high-parameter protein detection CyTOF2 Mass cytometry system Unveil new cell types and function with high-parameter protein detection DISCOVER MORE. IMAGINE MORE. MASS CYTOMETRY. THE FUTURE OF CYTOMETRY TODAY. Mass cytometry resolves

More information

Cell Cycle Phase Determination Kit

Cell Cycle Phase Determination Kit Cell Cycle Phase Determination Kit Item No. 10009349 Customer Service 800.364.9897 * Technical Support 888.526.5351 www.caymanchem.com TABLE OF CONTENTS GENERAL INFORMATION 3 Materials Supplied 3 Safety

More information

Let the BD FACSAria II accompany your best performance ever

Let the BD FACSAria II accompany your best performance ever Let the BD FACSAria II accompany your best performance ever Meet the new BD FACSAria II high-speed, fixed-alignment cuvette cell sorter. The first generation BD FACSAria system brought the complex world

More information

Automated Quadratic Characterization of Flow Cytometer Instrument Sensitivity (flowqb Package: Introductory Processing Using Data NIH))

Automated Quadratic Characterization of Flow Cytometer Instrument Sensitivity (flowqb Package: Introductory Processing Using Data NIH)) Automated Quadratic Characterization of Flow Cytometer Instrument Sensitivity (flowqb Package: Introductory Processing Using Data NIH)) October 14, 2013 1 Licensing Under the Artistic License, you are

More information

A Basic Guide. Institute of Medical Biology, University of Southern Denmark. Ungated Gate 1 (= R1) Gate 4 (=R4) Gate3 (=R3) Gate 2 (= R2) R3 R4

A Basic Guide. Institute of Medical Biology, University of Southern Denmark. Ungated Gate 1 (= R1) Gate 4 (=R4) Gate3 (=R3) Gate 2 (= R2) R3 R4 Flow Cytometry A Basic Guide R1 Ungated Gate 1 (= R1) R2 R3 R4 Gate 2 (= R2) Gate3 (=R3) Gate 4 (=R4) Graham Leslie, PhD Institute of Medical Biology, University of Southern Denmark Graham Leslie, PhD

More information

Chapter 12 Filters for FISH Imaging

Chapter 12 Filters for FISH Imaging Chapter 12 Filters for FISH Imaging Dan Osborn The application of in situ hybridization (ISH) has advanced from short lived, non-specific isotopic methods, to very specific, long lived, multiple color

More information

Selected Topics in Electrical Engineering: Flow Cytometry Data Analysis

Selected Topics in Electrical Engineering: Flow Cytometry Data Analysis Selected Topics in Electrical Engineering: Flow Cytometry Data Analysis Bilge Karaçalı, PhD Department of Electrical and Electronics Engineering Izmir Institute of Technology Outline Compensation and gating

More information

ab139418 Propidium Iodide Flow Cytometry Kit for Cell Cycle Analysis

ab139418 Propidium Iodide Flow Cytometry Kit for Cell Cycle Analysis ab139418 Propidium Iodide Flow Cytometry Kit for Cell Cycle Analysis Instructions for Use To determine cell cycle status in tissue culture cell lines by measuring DNA content using a flow cytometer. This

More information

Fluorescence Compensation. Jennifer Wilshire, PhD jennifer@flowjo.com

Fluorescence Compensation. Jennifer Wilshire, PhD jennifer@flowjo.com Fluorescence Compensation Jennifer Wilshire, PhD jennifer@flowjo.com Outline 1. Compensation Basics 2. Practical Applications -selecting comp controls (cells, stains?) 3. Multicolor Issues -spreading due

More information

The use of FACS for the selection of cell lines with superior productivity characteristics

The use of FACS for the selection of cell lines with superior productivity characteristics ESACT-UK, Cambridge 2007 The use of FACS for the selection of cell lines with superior productivity characteristics Jonathan Welsh Synopsis Why use FACS in bioprocess development Issues regarding use of

More information

1. Instrument Layout pg 2. 2. Summit Overview pg 3. 3. Data Storage and Data Files pgs 6-7. 4. Saving Data pg 7. 5. Start Up pg 8

1. Instrument Layout pg 2. 2. Summit Overview pg 3. 3. Data Storage and Data Files pgs 6-7. 4. Saving Data pg 7. 5. Start Up pg 8 Table of Contents 1. Instrument Layout pg 2 2. Summit Overview pg 3 3. Data Storage and Data Files pgs 6-7 4. Saving Data pg 7 5. Start Up pg 8 6. Choosing and Naming Parameters pg 9 7. Creating Histograms

More information

Application Note 10. Measurement of Cell Recovery. After Sorting with a Catcher-Tube-Based. Cell Sorter. Introduction

Application Note 10. Measurement of Cell Recovery. After Sorting with a Catcher-Tube-Based. Cell Sorter. Introduction Application Note 10 Measurement of Cell Recovery After Sorting with a Catcher-Tube-Based Cell Sorter Introduction In many experiments using sorted cells, it is important to be able to count the number

More information

Lab 2. Isolation of mononuclear cells from peripheral blood and separation into subpopulations

Lab 2. Isolation of mononuclear cells from peripheral blood and separation into subpopulations Lab 2 Isolation of mononuclear cells from peripheral blood and separation into subpopulations Supervisors: Sissela Broos sissela.broos@immun.lth.se tel: 222 96 78 Niclas Olsson niclas.olsson@immun.lth.se

More information

Fundamentals of modern UV-visible spectroscopy. Presentation Materials

Fundamentals of modern UV-visible spectroscopy. Presentation Materials Fundamentals of modern UV-visible spectroscopy Presentation Materials The Electromagnetic Spectrum E = hν ν = c / λ 1 Electronic Transitions in Formaldehyde 2 Electronic Transitions and Spectra of Atoms

More information

Science is hard. Flow cytometry should be easy.

Science is hard. Flow cytometry should be easy. Science is hard. Flow cytometry should be easy. TABLE OF CONTENTS 1 INTRODUCTION TO BD ACCURI C6 SOFTWARE... 1 1.1 Starting BD Accuri C6 Software... 1 1.2 BD Accuri C6 Software Workspace... 2 1.3 Opening

More information

Stepcount. Product Description: Closed transparent tubes with a metal screen, including a white matrix at the bottom. Cat. Reference: STP-25T

Stepcount. Product Description: Closed transparent tubes with a metal screen, including a white matrix at the bottom. Cat. Reference: STP-25T Product Description: Closed transparent tubes with a metal screen, including a white matrix at the bottom Cat. Reference: STP-25T Reagent provided:: 25 Stepcount tubes for 25 test INTENDED USE. Immunostep

More information

Easy to use. Compact. Flexible. Sorting Chip

Easy to use. Compact. Flexible. Sorting Chip SH800Z Cell Sorter The SH800Z is a compact, affordable, and easy to use cell sorter developed using the state- of-the art technologies from Sony. An array of automated mechanisms makes it an ideal sorter

More information

Bacterial Detection and Live/Dead Discrimination by Flow Cytometry

Bacterial Detection and Live/Dead Discrimination by Flow Cytometry A P P L I C A T I O N N O T E Bacterial Detection and Live/Dead Discrimination by Flow Cytometry M I C R O B I A L C Y T O M E T R Y BD FACSCalibur, BD FACSort Flow Cytometers Introduction Accurate determination

More information

CRITICAL ASPECTS OF STAINING FOR FLOW CYTOMETRY

CRITICAL ASPECTS OF STAINING FOR FLOW CYTOMETRY 页 码,1/6 CRITICAL ASPECTS OF STAINING FOR FLOW CYTOMETRY From Givan, A.L. (2000), chapter in In Living Color: Protocols in Flow Cytometry and Cell Sorting (R. Diamond and S. DeMaggio, eds). Springer, Berlin,

More information

Multicolor Bead Flow Cytometry Standardization Heba Degheidy MD, PhD, QCYM DB/OSEL/CDRH/FDA Manager of MCM Flow Cytometry Facility

Multicolor Bead Flow Cytometry Standardization Heba Degheidy MD, PhD, QCYM DB/OSEL/CDRH/FDA Manager of MCM Flow Cytometry Facility Multicolor Bead Flow Cytometry Standardization Heba Degheidy MD, PhD, QCYM DB/OSEL/CDRH/FDA Manager of MCM Flow Cytometry Facility The mention of commercial products, their sources, or their use in connection

More information

Instructions for Use. CyAn ADP. High-speed Analyzer. Summit 4.3. 0000050G June 2008. Beckman Coulter, Inc. 4300 N. Harbor Blvd. Fullerton, CA 92835

Instructions for Use. CyAn ADP. High-speed Analyzer. Summit 4.3. 0000050G June 2008. Beckman Coulter, Inc. 4300 N. Harbor Blvd. Fullerton, CA 92835 Instructions for Use CyAn ADP High-speed Analyzer Summit 4.3 0000050G June 2008 Beckman Coulter, Inc. 4300 N. Harbor Blvd. Fullerton, CA 92835 Overview Summit software is a Windows based application that

More information

SmartFlare RNA Detection Probes: Principles, protocols and troubleshooting

SmartFlare RNA Detection Probes: Principles, protocols and troubleshooting Technical Guide SmartFlare RNA Detection Probes: Principles, protocols and troubleshooting Principles of SmartFlare technology RNA detection traditionally requires transfection, laborious sample prep,

More information

ArC Amine Reactive Compensation Bead Kit

ArC Amine Reactive Compensation Bead Kit ArC Amine Reactive Compensation Bead Kit Catalog no. A1346 Table 1. Contents and storage information. Material Amount Composition Storage Stability ArC reactive beads (Component A) ArC negative beads (Component

More information

Cytell Cell Imaging System

Cytell Cell Imaging System Cytell Cell Imaging System Simplify your cell analysis and start changing tomorrow today www.gelifesciences.com/cytell The Cytell Cell Imaging System is an intuitive cell analysis instrument that streamlines

More information

Annexin V-FITC Apoptosis Detection Kit

Annexin V-FITC Apoptosis Detection Kit ab14085 Annexin V-FITC Apoptosis Detection Kit Instructions for Use For the rapid, sensitive and accurate measurement of Apoptosis in living cells (adherent and suspension). This product is for research

More information

Cell Discovery 360: Explore more possibilities.

Cell Discovery 360: Explore more possibilities. Cell Discovery 360: Explore more possibilities. Flexible solutions for the BioPharma laboratory Blood Banking Capillary Electrophoresis Centrifugation Flow Cytometry Genomics Lab Automation Lab Tools Particle

More information